{"lab":{"_id":"6ade8b48ff06824761708135","accr_number":"2392","country":"CZ","accr_body":"ČIA","address":"Revoluční 2214/35, 741 01 Nový Jičín","categories":["metrology"],"city":"Nový Jičín","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[18.0170385,49.5898097]},"map_coord":[49.5898097,18.0170385],"map_geo":"cai-mapa","methods_count":2,"name":"Laboratoře AGEL a.s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie tłokowych przyrządów do pomiaru objętości, w zakresie określonym w załączniku do świadectwa.","search_text":"laboratoře agel a.s. revoluční 2214/35, 741 01 nový jičín 2392","source_page_url":"https://www.cai.cz/?subjekt=2392-laboratore-agel-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"13-03-2030","website":"www.agellab.cz","certificate_date":"27.08.2026","certificate_no":"408/2026","certificate_replaces":"124/2025 z 13.03.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie tłokowych przyrządów do pomiaru objętości, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of piston-operated volumetric instruments, to the extent specified in the appendix to this Certificate.","zh":"活塞式容量器具的校准，范围见本证书附件。","cs":"Kalibrace pístových objemových měřidel, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące AGEL","lab_division_cs":"Kalibrační laboratoř AGEL","lab_division_en":"AGEL Calibration Laboratory","lab_division_zh":"AGEL 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"883fbe351d4d99ce68b467c32eb0ecca730fee05714dfac4565625283ccee571","source_pdf_url":"https://www.cai.cz/OA/pdf/408_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"f479af5618aa6f726176e8c7","lab_id":"6ade8b48ff06824761708135","country":"CZ","accr_number":"2392","accr_body":"ČIA","row_label":"1","test_object":"Objętość / Tłokowe przyrządy do pomiaru objętości - pipety","test_object_en":"Volume / Piston-operated volumetric instruments - pipettes","test_object_zh":"体积 / 活塞式容量器具 - 移液器","test_object_cs":"Objem / Pístová objemová měřidla - pipety","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"","range":"od 0,5 µl do 10 000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_en":[{"name":"","range":"0,5 µl to 10 000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_zh":[{"name":"","range":"0,5 µl 至 10 000 µl","cmc":"0,13 % + 0,01 µl"}],"parameters_cs":[{"name":"","range":"0,5 µl až 10 000 µl","cmc":"0,13 % + 0,01 µl"}],"technique":"Metoda grawimetryczna","technique_en":"Gravimetric method","technique_zh":"称量法","technique_cs":"Gravimetrická metoda","techniques":["Metoda grawimetryczna"],"techniques_en":["Gravimetric method"],"techniques_zh":["称量法"],"techniques_cs":["Gravimetrická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nod 0,5 µl do 10 000 µl CMC 0,13 % + 0,01 µl\nMetoda grawimetryczna","reference":"SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19)","norm_bases":["SOP č. 01","ČSN EN ISO 8655-6","EURAMET cg-19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":"Najmniejsza podana niepewność obejmuje wpływ operatora; nie uwzględniono statystycznej składowej niepewności.","note_en":"The lowest stated uncertainty includes the influence of the operator; the statistical component of uncertainty is not included.","note_zh":"所给最小不确定度包含操作者的影响，未计入不确定度的统计分量。","note_cs":"V nejnižší uvedené nejistotě je zahrnut vliv operátora, není započtena statistická složka nejistoty.","search_text":"Objętość / Tłokowe przyrządy do pomiaru objętości - pipety Wzorcowanie – objętość Metoda grawimetryczna od 0,5 µl do 10 000 µl CMC 0,13 % + 0,01 µl Objem / Pístová objemová měřidla - pipety Kalibrace – objem Gravimetrická metoda 0,5 µl až 10 000 µl CMC 0,13 % + 0,01 µl SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19) Objetosc / Tlokowe przyrzady do pomiaru objetosci - pipety Wzorcowanie – objetosc Metoda grawimetryczna od 0,5 µl do 10 000 µl CMC 0,13 % + 0,01 µl Objem / Pistova objemova meridla - pipety Kalibrace – objem Gravimetricka metoda 0,5 µl az 10 000 µl CMC 0,13 % + 0,01 µl SOP c. 01 (CSN EN ISO 8655-6; EURAMET cg-19)","search_en":"Volume / Piston-operated volumetric instruments - pipettes Calibration – volume Gravimetric method 0,5 µl to 10 000 µl CMC 0,13 % + 0,01 µl SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19)","search_zh":"体积 / 活塞式容量器具 - 移液器 校准 – 体积 称量法 0,5 µl 至 10 000 µl CMC 0,13 % + 0,01 µl SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fe77fe50cf3cd360d0eab85a","lab_id":"6ade8b48ff06824761708135","country":"CZ","accr_number":"2392","accr_body":"ČIA","row_label":"1","test_object":"Objętość / Tłokowe przyrządy do pomiaru objętości - dozowniki","test_object_en":"Volume / Piston-operated volumetric instruments - dispensers","test_object_zh":"体积 / 活塞式容量器具 - 分液器","test_object_cs":"Objem / Pístová objemová měřidla - dávkovače","methodology":"Wzorcowanie – objętość","methodology_en":"Calibration – volume","methodology_zh":"校准 – 体积","methodology_cs":"Kalibrace – objem","parameters":[{"name":"","range":"od 0,1 ml do 100 ml","cmc":"0,12 %"}],"parameters_en":[{"name":"","range":"0,1 ml to 100 ml","cmc":"0,12 %"}],"parameters_zh":[{"name":"","range":"0,1 ml 至 100 ml","cmc":"0,12 %"}],"parameters_cs":[{"name":"","range":"0,1 ml až 100 ml","cmc":"0,12 %"}],"technique":"Metoda grawimetryczna","technique_en":"Gravimetric method","technique_zh":"称量法","technique_cs":"Gravimetrická metoda","techniques":["Metoda grawimetryczna"],"techniques_en":["Gravimetric method"],"techniques_zh":["称量法"],"techniques_cs":["Gravimetrická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość\nod 0,1 ml do 100 ml CMC 0,12 %\nMetoda grawimetryczna","reference":"SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19)","norm_bases":["SOP č. 01","ČSN EN ISO 8655-6","EURAMET cg-19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość","regulatory_area_en":"CMC for the field of measured quantity: Volume","regulatory_area_zh":"被测量领域的CMC：体积","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem","flexible":false,"flexibility":null,"outside_premises":false,"note":"Najmniejsza podana niepewność obejmuje wpływ operatora; nie uwzględniono statystycznej składowej niepewności.","note_en":"The lowest stated uncertainty includes the influence of the operator; the statistical component of uncertainty is not included.","note_zh":"所给最小不确定度包含操作者的影响，未计入不确定度的统计分量。","note_cs":"V nejnižší uvedené nejistotě je zahrnut vliv operátora, není započtena statistická složka nejistoty.","search_text":"Objętość / Tłokowe przyrządy do pomiaru objętości - dozowniki Wzorcowanie – objętość Metoda grawimetryczna od 0,1 ml do 100 ml CMC 0,12 % Objem / Pístová objemová měřidla - dávkovače Kalibrace – objem Gravimetrická metoda 0,1 ml až 100 ml CMC 0,12 % SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19) Objetosc / Tlokowe przyrzady do pomiaru objetosci - dozowniki Wzorcowanie – objetosc Metoda grawimetryczna od 0,1 ml do 100 ml CMC 0,12 % Objem / Pistova objemova meridla - davkovace Kalibrace – objem Gravimetricka metoda 0,1 ml az 100 ml CMC 0,12 % SOP c. 01 (CSN EN ISO 8655-6; EURAMET cg-19)","search_en":"Volume / Piston-operated volumetric instruments - dispensers Calibration – volume Gravimetric method 0,1 ml to 100 ml CMC 0,12 % SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19)","search_zh":"体积 / 活塞式容量器具 - 分液器 校准 – 体积 称量法 0,1 ml 至 100 ml CMC 0,12 % SOP č. 01 (ČSN EN ISO 8655-6; EURAMET cg-19)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}