{"lab":{"_id":"6ade8b46ff06824761708131","accr_number":"2388","country":"CZ","accr_body":"ČIA","address":"Počernická 272/96, Malešice, 108 00 Praha 10","categories":["metrology"],"city":"Praha 10","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.5095839,50.0828694]},"map_coord":[50.0828694,14.5095839],"map_geo":"cai-mapa","methods_count":13,"name":"SVMTech s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ruch mechaniczny, drgania, wielkości elektryczne, częstotliwość, wielkości akustyczne i drgania mechaniczne.","search_text":"svmtech s.r.o. počernická 272/96, malešice, 108 00 praha 10 2388","source_page_url":"https://www.cai.cz/?subjekt=2388-svmtech-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"23-09-2029","website":"www.svmtech.cz","certificate_date":"23.09.2024","certificate_no":"492/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ruch mechaniczny, drgania, wielkości elektryczne, częstotliwość, wielkości akustyczne i drgania mechaniczne.","en":"Calibration of measuring instruments in the fields of mechanical motion, vibration, electrical quantities, frequency, acoustic quantities and mechanical vibration.","zh":"机械运动、振动、电学量、频率、声学量和机械振荡领域测量仪器的校准。","cs":"Kalibrace měřidel v oborech mechanický pohyb, vibrace, elektrické veličiny, frekvence, akustické veličiny a mechanické kmitání."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"CENTRUM WZORCOWANIA SVMTech","lab_division_cs":"KALIBRAČNÍ CENTRUM SVMTech","lab_division_en":"SVMTech CALIBRATION CENTRE","lab_division_zh":"SVMTech 校准中心","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"30e7bd110644a05eaed623e41d8248c70d207d0ce4bf587ccca17a0f2f4e8ff6","source_pdf_url":"https://www.cai.cz/OA/pdf/P492_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P492_2024_EN.pdf"},"methods":[{"_id":"67ae38aaa52c5820b387893c","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"1","test_object":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / wzorce drgań","test_object_en":"Acceleration of linear mechanical vibration of harmonic wave form / vibration standards","test_object_zh":"简谐直线机械振动加速度 / 振动标准器","test_object_cs":"Zrychlení přímočarých mechanických vibrací harmonického průběhu / etalony vibrací","methodology":"Wzorcowanie – ruch mechaniczny, drgania","methodology_en":"Calibration – mechanical motion, vibrations","methodology_zh":"校准 – 机械运动、振动","methodology_cs":"Kalibrace – mechanický pohyb, vibrace","parameters":[{"name":"5 Hz do 6,3 kHz","range":"od 0,01 m·s⁻² do 700 m·s⁻²","cmc":"1,2 %"}],"parameters_en":[{"name":"5 Hz to 6,3 kHz","range":"0,01 m·s⁻² to 700 m·s⁻²","cmc":"1,2 %"}],"parameters_zh":[{"name":"5 Hz 至 6,3 kHz","range":"0,01 m·s⁻² 至 700 m·s⁻²","cmc":"1,2 %"}],"parameters_cs":[{"name":"5 Hz až 6,3 kHz","range":"0,01 m·s⁻² až 700 m·s⁻²","cmc":"1,2 %"}],"technique":"Pomiar bezpośredni czujnikiem wzorcowym","technique_en":"Direct measurement with a standard sensor","technique_zh":"用标准传感器直接测量","technique_cs":"Přímé měření etalonovým snímačem","techniques":["Pomiar bezpośredni czujnikiem wzorcowym"],"techniques_en":["Direct measurement with a standard sensor"],"techniques_zh":["用标准传感器直接测量"],"techniques_cs":["Přímé měření etalonovým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny, drgania\n5 Hz do 6,3 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 %\nPomiar bezpośredni czujnikiem wzorcowym","reference":"KP 01 (ČSN ISO 16063-44)","norm_bases":["KP 01","ČSN ISO 16063-44"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny, drgania","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion, vibrations","regulatory_area_zh":"被测量领域的CMC：机械运动、振动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb, vibrace","flexible":false,"flexibility":null,"outside_premises":false,"note":"Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,81 m·s⁻²","note_en":"Acceleration can also be given in the units g, sensitivity of acceleration sensors in the units pC/g or mV/g, where 1 g = 9.81 m·s⁻²","note_zh":"加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，1 g = 9,81 m·s⁻²","note_cs":"Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g resp. mV/g, pro 1 g = 9,81 ms⁻²","search_text":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / wzorce drgań Wzorcowanie – ruch mechaniczny, drgania Pomiar bezpośredni czujnikiem wzorcowym 5 Hz do 6,3 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 % Zrychlení přímočarých mechanických vibrací harmonického průběhu / etalony vibrací Kalibrace – mechanický pohyb, vibrace Přímé měření etalonovým snímačem 5 Hz až 6,3 kHz 0,01 m·s⁻² až 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-44) Przyspieszenie prostoliniowych drgan mechanicznych o przebiegu harmonicznym / wzorce drgan Wzorcowanie – ruch mechaniczny, drgania Pomiar bezposredni czujnikiem wzorcowym 5 Hz do 6,3 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 % Zrychleni primocarych mechanickych vibraci harmonickeho prubehu / etalony vibraci Kalibrace – mechanicky pohyb, vibrace Prime mereni etalonovym snimacem 5 Hz az 6,3 kHz 0,01 m·s⁻² az 700 m·s⁻² CMC 1,2 % KP 01 (CSN ISO 16063-44)","search_en":"Acceleration of linear mechanical vibration of harmonic wave form / vibration standards Calibration – mechanical motion, vibrations Direct measurement with a standard sensor 5 Hz to 6,3 kHz 0,01 m·s⁻² to 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-44)","search_zh":"简谐直线机械振动加速度 / 振动标准器 校准 – 机械运动、振动 用标准传感器直接测量 5 Hz 至 6,3 kHz 0,01 m·s⁻² 至 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-44)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c4b6532bc014e44fc03741f","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"2","test_object":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / systemy do badań wibracyjnych","test_object_en":"Acceleration of linear mechanical vibration of harmonic wave form / vibration test systems","test_object_zh":"简谐直线机械振动加速度 / 振动试验系统","test_object_cs":"Zrychlení přímočarých mechanických vibrací harmonického průběhu / vibrační testovací systémy","methodology":"Wzorcowanie – ruch mechaniczny, drgania","methodology_en":"Calibration – mechanical motion, vibrations","methodology_zh":"校准 – 机械运动、振动","methodology_cs":"Kalibrace – mechanický pohyb, vibrace","parameters":[{"name":"5 Hz do 2,5 kHz","range":"od 0,01 m·s⁻² do 700 m·s⁻²","cmc":"1,2 %"}],"parameters_en":[{"name":"5 Hz to 2,5 kHz","range":"0,01 m·s⁻² to 700 m·s⁻²","cmc":"1,2 %"}],"parameters_zh":[{"name":"5 Hz 至 2,5 kHz","range":"0,01 m·s⁻² 至 700 m·s⁻²","cmc":"1,2 %"}],"parameters_cs":[{"name":"5 Hz až 2,5 kHz","range":"0,01 m·s⁻² až 700 m·s⁻²","cmc":"1,2 %"}],"technique":"Pomiar bezpośredni czujnikiem wzorcowym","technique_en":"Direct measurement with a standard sensor","technique_zh":"用标准传感器直接测量","technique_cs":"Přímé měření etalonovým snímačem","techniques":["Pomiar bezpośredni czujnikiem wzorcowym"],"techniques_en":["Direct measurement with a standard sensor"],"techniques_zh":["用标准传感器直接测量"],"techniques_cs":["Přímé měření etalonovým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny, drgania\n5 Hz do 2,5 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 %\nPomiar bezpośredni czujnikiem wzorcowym","reference":"KP 01 (ČSN ISO 16063-44, ČSN ISO 16063-21)","norm_bases":["KP 01","ČSN ISO 16063-44","ČSN ISO 16063-21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny, drgania","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion, vibrations","regulatory_area_zh":"被测量领域的CMC：机械运动、振动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb, vibrace","flexible":false,"flexibility":null,"outside_premises":true,"note":"Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,81 m·s⁻²","note_en":"Acceleration can also be given in the units g, sensitivity of acceleration sensors in the units pC/g or mV/g, where 1 g = 9.81 m·s⁻²","note_zh":"加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，1 g = 9,81 m·s⁻²","note_cs":"Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g resp. mV/g, pro 1 g = 9,81 ms⁻²","search_text":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / systemy do badań wibracyjnych Wzorcowanie – ruch mechaniczny, drgania Pomiar bezpośredni czujnikiem wzorcowym 5 Hz do 2,5 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 % Zrychlení přímočarých mechanických vibrací harmonického průběhu / vibrační testovací systémy Kalibrace – mechanický pohyb, vibrace Přímé měření etalonovým snímačem 5 Hz až 2,5 kHz 0,01 m·s⁻² až 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-44, ČSN ISO 16063-21) Przyspieszenie prostoliniowych drgan mechanicznych o przebiegu harmonicznym / systemy do badan wibracyjnych Wzorcowanie – ruch mechaniczny, drgania Pomiar bezposredni czujnikiem wzorcowym 5 Hz do 2,5 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 % Zrychleni primocarych mechanickych vibraci harmonickeho prubehu / vibracni testovaci systemy Kalibrace – mechanicky pohyb, vibrace Prime mereni etalonovym snimacem 5 Hz az 2,5 kHz 0,01 m·s⁻² az 700 m·s⁻² CMC 1,2 % KP 01 (CSN ISO 16063-44, CSN ISO 16063-21)","search_en":"Acceleration of linear mechanical vibration of harmonic wave form / vibration test systems Calibration – mechanical motion, vibrations Direct measurement with a standard sensor 5 Hz to 2,5 kHz 0,01 m·s⁻² to 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-44, ČSN ISO 16063-21)","search_zh":"简谐直线机械振动加速度 / 振动试验系统 校准 – 机械运动、振动 用标准传感器直接测量 5 Hz 至 2,5 kHz 0,01 m·s⁻² 至 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-44, ČSN ISO 16063-21)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25c22e1b90a385790156f74a","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"3","test_object":"Czułość czujników drgań / czujniki drgań","test_object_en":"Sensitivity of vibration sensors / vibration sensors","test_object_zh":"振动传感器灵敏度 / 振动传感器","test_object_cs":"Citlivost snímačů vibrací / snímače vibrací","methodology":"Wzorcowanie – ruch mechaniczny, drgania","methodology_en":"Calibration – mechanical motion, vibrations","methodology_zh":"校准 – 机械运动、振动","methodology_cs":"Kalibrace – mechanický pohyb, vibrace","parameters":[{"name":"5 Hz do 10 kHz","range":"od 0,01 pC/m·s⁻² do 100 pC/m·s⁻²","cmc":"1,1 %"},{"name":"5 Hz do 10 kHz","range":"od 0,01 mV/m·s⁻² do 3000 mV/m·s⁻²","cmc":"1,1 %"}],"parameters_en":[{"name":"5 Hz to 10 kHz","range":"0,01 pC/m·s⁻² to 100 pC/m·s⁻²","cmc":"1,1 %"},{"name":"5 Hz to 10 kHz","range":"0,01 mV/m·s⁻² to 3000 mV/m·s⁻²","cmc":"1,1 %"}],"parameters_zh":[{"name":"5 Hz 至 10 kHz","range":"0,01 pC/m·s⁻² 至 100 pC/m·s⁻²","cmc":"1,1 %"},{"name":"5 Hz 至 10 kHz","range":"0,01 mV/m·s⁻² 至 3000 mV/m·s⁻²","cmc":"1,1 %"}],"parameters_cs":[{"name":"5 Hz až 10 kHz","range":"0,01 pC/m·s⁻² až 100 pC/m·s⁻²","cmc":"1,1 %"},{"name":"5 Hz až 10 kHz","range":"0,01 mV/m·s⁻² až 3000 mV/m·s⁻²","cmc":"1,1 %"}],"technique":"Porównanie z czujnikiem wzorcowym","technique_en":"Comparison with a standard sensor","technique_zh":"与标准传感器比较","technique_cs":"Porovnání s etalonovým snímačem","techniques":["Porównanie z czujnikiem wzorcowym"],"techniques_en":["Comparison with a standard sensor"],"techniques_zh":["与标准传感器比较"],"techniques_cs":["Porovnání s etalonovým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny, drgania\nZakres:\n5 Hz do 10 kHz od 0,01 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,1 %\n5 Hz do 10 kHz od 0,01 mV/m·s⁻² do 3000 mV/m·s⁻² CMC 1,1 %\nPorównanie z czujnikiem wzorcowym","reference":"KP 01 (ČSN ISO 16063-21)","norm_bases":["KP 01","ČSN ISO 16063-21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny, drgania","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion, vibrations","regulatory_area_zh":"被测量领域的CMC：机械运动、振动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb, vibrace","flexible":false,"flexibility":null,"outside_premises":false,"note":"Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,81 m·s⁻²","note_en":"Acceleration can also be given in the units g, sensitivity of acceleration sensors in the units pC/g or mV/g, where 1 g = 9.81 m·s⁻²","note_zh":"加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，1 g = 9,81 m·s⁻²","note_cs":"Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g resp. mV/g, pro 1 g = 9,81 ms⁻²","search_text":"Czułość czujników drgań / czujniki drgań Wzorcowanie – ruch mechaniczny, drgania Porównanie z czujnikiem wzorcowym 5 Hz do 10 kHz od 0,01 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,1 % 5 Hz do 10 kHz od 0,01 mV/m·s⁻² do 3000 mV/m·s⁻² CMC 1,1 % Citlivost snímačů vibrací / snímače vibrací Kalibrace – mechanický pohyb, vibrace Porovnání s etalonovým snímačem 5 Hz až 10 kHz 0,01 pC/m·s⁻² až 100 pC/m·s⁻² CMC 1,1 % 5 Hz až 10 kHz 0,01 mV/m·s⁻² až 3000 mV/m·s⁻² CMC 1,1 % KP 01 (ČSN ISO 16063-21) Czulosc czujnikow drgan / czujniki drgan Wzorcowanie – ruch mechaniczny, drgania Porownanie z czujnikiem wzorcowym 5 Hz do 10 kHz od 0,01 pC/m·s⁻² do 100 pC/m·s⁻² CMC 1,1 % 5 Hz do 10 kHz od 0,01 mV/m·s⁻² do 3000 mV/m·s⁻² CMC 1,1 % Citlivost snimacu vibraci / snimace vibraci Kalibrace – mechanicky pohyb, vibrace Porovnani s etalonovym snimacem 5 Hz az 10 kHz 0,01 pC/m·s⁻² az 100 pC/m·s⁻² CMC 1,1 % 5 Hz az 10 kHz 0,01 mV/m·s⁻² az 3000 mV/m·s⁻² CMC 1,1 % KP 01 (CSN ISO 16063-21)","search_en":"Sensitivity of vibration sensors / vibration sensors Calibration – mechanical motion, vibrations Comparison with a standard sensor 5 Hz to 10 kHz 0,01 pC/m·s⁻² to 100 pC/m·s⁻² CMC 1,1 % 5 Hz to 10 kHz 0,01 mV/m·s⁻² to 3000 mV/m·s⁻² CMC 1,1 % KP 01 (ČSN ISO 16063-21)","search_zh":"振动传感器灵敏度 / 振动传感器 校准 – 机械运动、振动 与标准传感器比较 5 Hz 至 10 kHz 0,01 pC/m·s⁻² 至 100 pC/m·s⁻² CMC 1,1 % 5 Hz 至 10 kHz 0,01 mV/m·s⁻² 至 3000 mV/m·s⁻² CMC 1,1 % KP 01 (ČSN ISO 16063-21)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb8bff573958fce8281c5fd5","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"4","test_object":"Przyspieszenie / wibrometry z czujnikiem","test_object_en":"Acceleration / vibrometers with sensor","test_object_zh":"加速度 / 带传感器的测振仪","test_object_cs":"Zrychlení / vibrometry se snímačem","methodology":"Wzorcowanie – ruch mechaniczny, drgania","methodology_en":"Calibration – mechanical motion, vibrations","methodology_zh":"校准 – 机械运动、振动","methodology_cs":"Kalibrace – mechanický pohyb, vibrace","parameters":[{"name":"5 Hz do 6,3 kHz","range":"od 0,01 m·s⁻² do 700 m·s⁻²","cmc":"1,2 %"}],"parameters_en":[{"name":"5 Hz to 6,3 kHz","range":"0,01 m·s⁻² to 700 m·s⁻²","cmc":"1,2 %"}],"parameters_zh":[{"name":"5 Hz 至 6,3 kHz","range":"0,01 m·s⁻² 至 700 m·s⁻²","cmc":"1,2 %"}],"parameters_cs":[{"name":"5 Hz až 6,3 kHz","range":"0,01 m·s⁻² až 700 m·s⁻²","cmc":"1,2 %"}],"technique":"Porównanie z czujnikiem wzorcowym","technique_en":"Comparison with a standard sensor","technique_zh":"与标准传感器比较","technique_cs":"Porovnání s etalonovým snímačem","techniques":["Porównanie z czujnikiem wzorcowym"],"techniques_en":["Comparison with a standard sensor"],"techniques_zh":["与标准传感器比较"],"techniques_cs":["Porovnání s etalonovým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny, drgania\n5 Hz do 6,3 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 %\nPorównanie z czujnikiem wzorcowym","reference":"KP 01 (ČSN ISO 16063-21)","norm_bases":["KP 01","ČSN ISO 16063-21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny, drgania","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion, vibrations","regulatory_area_zh":"被测量领域的CMC：机械运动、振动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb, vibrace","flexible":false,"flexibility":null,"outside_premises":false,"note":"Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,81 m·s⁻²","note_en":"Acceleration can also be given in the units g, sensitivity of acceleration sensors in the units pC/g or mV/g, where 1 g = 9.81 m·s⁻²","note_zh":"加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，1 g = 9,81 m·s⁻²","note_cs":"Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g resp. mV/g, pro 1 g = 9,81 ms⁻²","search_text":"Przyspieszenie / wibrometry z czujnikiem Wzorcowanie – ruch mechaniczny, drgania Porównanie z czujnikiem wzorcowym 5 Hz do 6,3 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 % Zrychlení / vibrometry se snímačem Kalibrace – mechanický pohyb, vibrace Porovnání s etalonovým snímačem 5 Hz až 6,3 kHz 0,01 m·s⁻² až 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-21) Przyspieszenie / wibrometry z czujnikiem Wzorcowanie – ruch mechaniczny, drgania Porownanie z czujnikiem wzorcowym 5 Hz do 6,3 kHz od 0,01 m·s⁻² do 700 m·s⁻² CMC 1,2 % Zrychleni / vibrometry se snimacem Kalibrace – mechanicky pohyb, vibrace Porovnani s etalonovym snimacem 5 Hz az 6,3 kHz 0,01 m·s⁻² az 700 m·s⁻² CMC 1,2 % KP 01 (CSN ISO 16063-21)","search_en":"Acceleration / vibrometers with sensor Calibration – mechanical motion, vibrations Comparison with a standard sensor 5 Hz to 6,3 kHz 0,01 m·s⁻² to 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-21)","search_zh":"加速度 / 带传感器的测振仪 校准 – 机械运动、振动 与标准传感器比较 5 Hz 至 6,3 kHz 0,01 m·s⁻² 至 700 m·s⁻² CMC 1,2 % KP 01 (ČSN ISO 16063-21)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"295b31f619dd32b8e2d538f8","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"4","test_object":"Prędkość / wibrometry z czujnikiem","test_object_en":"Velocity / vibrometers with sensor","test_object_zh":"速度 / 带传感器的测振仪","test_object_cs":"Rychlost / vibrometry se snímačem","methodology":"Wzorcowanie – ruch mechaniczny, drgania","methodology_en":"Calibration – mechanical motion, vibrations","methodology_zh":"校准 – 机械运动、振动","methodology_cs":"Kalibrace – mechanický pohyb, vibrace","parameters":[{"name":"5 Hz do 6,3 kHz","range":"od 0,01 m·s⁻¹ do 700 mm·s⁻¹","cmc":"1,2 %"}],"parameters_en":[{"name":"5 Hz to 6,3 kHz","range":"0,01 m·s⁻¹ to 700 mm·s⁻¹","cmc":"1,2 %"}],"parameters_zh":[{"name":"5 Hz 至 6,3 kHz","range":"0,01 m·s⁻¹ 至 700 mm·s⁻¹","cmc":"1,2 %"}],"parameters_cs":[{"name":"5 Hz až 6,3 kHz","range":"0,01 m·s⁻¹ až 700 mm·s⁻¹","cmc":"1,2 %"}],"technique":"Porównanie z czujnikiem wzorcowym","technique_en":"Comparison with a standard sensor","technique_zh":"与标准传感器比较","technique_cs":"Porovnání s etalonovým snímačem","techniques":["Porównanie z czujnikiem wzorcowym"],"techniques_en":["Comparison with a standard sensor"],"techniques_zh":["与标准传感器比较"],"techniques_cs":["Porovnání s etalonovým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny, drgania\n5 Hz do 6,3 kHz od 0,01 m·s⁻¹ do 700 mm·s⁻¹ CMC 1,2 %\nPorównanie z czujnikiem wzorcowym","reference":"KP 01 (ČSN ISO 16063-21)","norm_bases":["KP 01","ČSN ISO 16063-21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny, drgania","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion, vibrations","regulatory_area_zh":"被测量领域的CMC：机械运动、振动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb, vibrace","flexible":false,"flexibility":null,"outside_premises":false,"note":"Przyspieszenie można podawać także w jednostkach g, czułość czujników w pC/g lub mV/g, przy czym 1 g = 9,81 m·s⁻²","note_en":"Acceleration can also be given in the units g, sensitivity of acceleration sensors in the units pC/g or mV/g, where 1 g = 9.81 m·s⁻²","note_zh":"加速度也可用 g 表示，传感器灵敏度用 pC/g 或 mV/g 表示，1 g = 9,81 m·s⁻²","note_cs":"Zrychlení je možno uvádět i v jednotkách g, citlivost snímačů v pC/g resp. mV/g, pro 1 g = 9,81 ms⁻²","search_text":"Prędkość / wibrometry z czujnikiem Wzorcowanie – ruch mechaniczny, drgania Porównanie z czujnikiem wzorcowym 5 Hz do 6,3 kHz od 0,01 m·s⁻¹ do 700 mm·s⁻¹ CMC 1,2 % Rychlost / vibrometry se snímačem Kalibrace – mechanický pohyb, vibrace Porovnání s etalonovým snímačem 5 Hz až 6,3 kHz 0,01 m·s⁻¹ až 700 mm·s⁻¹ CMC 1,2 % KP 01 (ČSN ISO 16063-21) Predkosc / wibrometry z czujnikiem Wzorcowanie – ruch mechaniczny, drgania Porownanie z czujnikiem wzorcowym 5 Hz do 6,3 kHz od 0,01 m·s⁻¹ do 700 mm·s⁻¹ CMC 1,2 % Rychlost / vibrometry se snimacem Kalibrace – mechanicky pohyb, vibrace Porovnani s etalonovym snimacem 5 Hz az 6,3 kHz 0,01 m·s⁻¹ az 700 mm·s⁻¹ CMC 1,2 % KP 01 (CSN ISO 16063-21)","search_en":"Velocity / vibrometers with sensor Calibration – mechanical motion, vibrations Comparison with a standard sensor 5 Hz to 6,3 kHz 0,01 m·s⁻¹ to 700 mm·s⁻¹ CMC 1,2 % KP 01 (ČSN ISO 16063-21)","search_zh":"速度 / 带传感器的测振仪 校准 – 机械运动、振动 与标准传感器比较 5 Hz 至 6,3 kHz 0,01 m·s⁻¹ 至 700 mm·s⁻¹ CMC 1,2 % KP 01 (ČSN ISO 16063-21)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6f0c74b671469ccc1ecaef60","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Multimetry, analizatory sygnałów, wibrometry, kontrolery systemów do badań wibracyjnych","test_object_en":"DC Voltage / Multimeters, signal analyzers, vibrometers, controllers for vibration test systems","test_object_zh":"直流电压 / 万用表、信号分析仪、测振仪、振动试验系统控制器","test_object_cs":"Stejnosměrné napětí / Multimetry, signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,010 % + 0,10 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"100 mV to 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"1 V to 10 V","cmc":"0,010 % + 0,10 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"1 V 至 10 V","cmc":"0,010 % + 0,10 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"100 mV až 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"1 V až 10 V","cmc":"0,010 % + 0,10 mV"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,010 % + 0,0041 mV\nod 100 mV do 1 V CMC 0,010 % + 0,010 mV\nod 1 V do 10 V CMC 0,010 % + 0,10 mV\nPorównanie z multimetrem wzorcowym","reference":"KP 02","norm_bases":["KP 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Multimetry, analizatory sygnałów, wibrometry, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,010 % + 0,0041 mV od 100 mV do 1 V CMC 0,010 % + 0,010 mV od 1 V do 10 V CMC 0,010 % + 0,10 mV Stejnosměrné napětí / Multimetry, signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 0 mV až 100 mV CMC 0,010 % + 0,0041 mV 100 mV až 1 V CMC 0,010 % + 0,010 mV 1 V až 10 V CMC 0,010 % + 0,10 mV KP 02 Napiecie stale / Multimetry, analizatory sygnalow, wibrometry, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,010 % + 0,0041 mV od 100 mV do 1 V CMC 0,010 % + 0,010 mV od 1 V do 10 V CMC 0,010 % + 0,10 mV Stejnosmerne napeti / Multimetry, signalove analyzatory, vibrometry, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 0 mV az 100 mV CMC 0,010 % + 0,0041 mV 100 mV az 1 V CMC 0,010 % + 0,010 mV 1 V az 10 V CMC 0,010 % + 0,10 mV KP 02","search_en":"DC Voltage / Multimeters, signal analyzers, vibrometers, controllers for vibration test systems Calibration – electrical quantities Comparison with a reference multimeter 0 mV to 100 mV CMC 0,010 % + 0,0041 mV 100 mV to 1 V CMC 0,010 % + 0,010 mV 1 V to 10 V CMC 0,010 % + 0,10 mV KP 02","search_zh":"直流电压 / 万用表、信号分析仪、测振仪、振动试验系统控制器 校准 – 电学量 与标准万用表比较 0 mV 至 100 mV CMC 0,010 % + 0,0041 mV 100 mV 至 1 V CMC 0,010 % + 0,010 mV 1 V 至 10 V CMC 0,010 % + 0,10 mV KP 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"37a82bcfffb84295ebdc80aa","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Generatory, kontrolery systemów do badań wibracyjnych","test_object_en":"DC Voltage / Generators, controllers for vibration test systems","test_object_zh":"直流电压 / 发生器、振动试验系统控制器","test_object_cs":"Stejnosměrné napětí / Generátory, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,010 % + 0,10 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"100 mV to 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"1 V to 10 V","cmc":"0,010 % + 0,10 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"1 V 至 10 V","cmc":"0,010 % + 0,10 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,010 % + 0,0041 mV"},{"name":"","range":"100 mV až 1 V","cmc":"0,010 % + 0,010 mV"},{"name":"","range":"1 V až 10 V","cmc":"0,010 % + 0,10 mV"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement with a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement with a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,010 % + 0,0041 mV\nod 100 mV do 1 V CMC 0,010 % + 0,010 mV\nod 1 V do 10 V CMC 0,010 % + 0,10 mV\nBezpośredni pomiar multimetrem wzorcowym","reference":"KP02","norm_bases":["KP02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Generatory, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Bezpośredni pomiar multimetrem wzorcowym od 0 mV do 100 mV CMC 0,010 % + 0,0041 mV od 100 mV do 1 V CMC 0,010 % + 0,010 mV od 1 V do 10 V CMC 0,010 % + 0,10 mV Stejnosměrné napětí / Generátory, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 100 mV CMC 0,010 % + 0,0041 mV 100 mV až 1 V CMC 0,010 % + 0,010 mV 1 V až 10 V CMC 0,010 % + 0,10 mV KP02 Napiecie stale / Generatory, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Bezposredni pomiar multimetrem wzorcowym od 0 mV do 100 mV CMC 0,010 % + 0,0041 mV od 100 mV do 1 V CMC 0,010 % + 0,010 mV od 1 V do 10 V CMC 0,010 % + 0,10 mV Stejnosmerne napeti / Generatory, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 100 mV CMC 0,010 % + 0,0041 mV 100 mV az 1 V CMC 0,010 % + 0,010 mV 1 V az 10 V CMC 0,010 % + 0,10 mV KP02","search_en":"DC Voltage / Generators, controllers for vibration test systems Calibration – electrical quantities Direct measurement with a reference multimeter 0 mV to 100 mV CMC 0,010 % + 0,0041 mV 100 mV to 1 V CMC 0,010 % + 0,010 mV 1 V to 10 V CMC 0,010 % + 0,10 mV KP02","search_zh":"直流电压 / 发生器、振动试验系统控制器 校准 – 电学量 用标准万用表直接测量 0 mV 至 100 mV CMC 0,010 % + 0,0041 mV 100 mV 至 1 V CMC 0,010 % + 0,010 mV 1 V 至 10 V CMC 0,010 % + 0,10 mV KP02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e6c0b177383e61bba5b2910f","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / Multimetry, analizatory sygnałów, wibrometry, kontrolery systemów do badań wibracyjnych","test_object_en":"AC Voltage / Multimeters, signal analyzers, vibrometers, controllers for vibration test systems","test_object_zh":"交流电压 / 万用表、信号分析仪、测振仪、振动试验系统控制器","test_object_cs":"Střídavé napětí / Multimetry, signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 kHz","range":"od 10 mV do 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz do 20 kHz","range":"od 100 mV do 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,10 % + 3,0 mV"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"10 mV to 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz to 20 kHz","range":"100 mV to 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"0,10 % + 3,0 mV"}],"parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"10 mV 至 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz 至 20 kHz","range":"100 mV 至 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,10 % + 3,0 mV"}],"parameters_cs":[{"name":"10 Hz až 20 kHz","range":"10 mV až 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz až 20 kHz","range":"100 mV až 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz až 20 kHz","range":"1 V až 10 V","cmc":"0,10 % + 3,0 mV"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 kHz od 10 mV do 100 mV CMC 0,10 % + 0,030 mV\n10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,30 mV\n10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 3,0 mV\nPorównanie z multimetrem wzorcowym","reference":"KP 02","norm_bases":["KP 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Multimetry, analizatory sygnałów, wibrometry, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 10 Hz do 20 kHz od 10 mV do 100 mV CMC 0,10 % + 0,030 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,30 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 3,0 mV Střídavé napětí / Multimetry, signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 10 Hz až 20 kHz 10 mV až 100 mV CMC 0,10 % + 0,030 mV 10 Hz až 20 kHz 100 mV až 1 V CMC 0,10 % + 0,30 mV 10 Hz až 20 kHz 1 V až 10 V CMC 0,10 % + 3,0 mV KP 02 Napiecie przemienne / Multimetry, analizatory sygnalow, wibrometry, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 10 Hz do 20 kHz od 10 mV do 100 mV CMC 0,10 % + 0,030 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,30 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 3,0 mV Stridave napeti / Multimetry, signalove analyzatory, vibrometry, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 10 Hz az 20 kHz 10 mV az 100 mV CMC 0,10 % + 0,030 mV 10 Hz az 20 kHz 100 mV az 1 V CMC 0,10 % + 0,30 mV 10 Hz az 20 kHz 1 V az 10 V CMC 0,10 % + 3,0 mV KP 02","search_en":"AC Voltage / Multimeters, signal analyzers, vibrometers, controllers for vibration test systems Calibration – electrical quantities Comparison with a reference multimeter 10 Hz to 20 kHz 10 mV to 100 mV CMC 0,10 % + 0,030 mV 10 Hz to 20 kHz 100 mV to 1 V CMC 0,10 % + 0,30 mV 10 Hz to 20 kHz 1 V to 10 V CMC 0,10 % + 3,0 mV KP 02","search_zh":"交流电压 / 万用表、信号分析仪、测振仪、振动试验系统控制器 校准 – 电学量 与标准万用表比较 10 Hz 至 20 kHz 10 mV 至 100 mV CMC 0,10 % + 0,030 mV 10 Hz 至 20 kHz 100 mV 至 1 V CMC 0,10 % + 0,30 mV 10 Hz 至 20 kHz 1 V 至 10 V CMC 0,10 % + 3,0 mV KP 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ee8cf3e9a83d2f5d10e42ffe","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / Generatory, kontrolery systemów do badań wibracyjnych","test_object_en":"AC Voltage / Generators, controllers for vibration test systems","test_object_zh":"交流电压 / 发生器、振动试验系统控制器","test_object_cs":"Střídavé napětí / Generátory, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 kHz","range":"od 10 mV do 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz do 20 kHz","range":"od 100 mV do 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,10 % + 3,0 mV"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"10 mV to 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz to 20 kHz","range":"100 mV to 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"0,10 % + 3,0 mV"}],"parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"10 mV 至 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz 至 20 kHz","range":"100 mV 至 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,10 % + 3,0 mV"}],"parameters_cs":[{"name":"10 Hz až 20 kHz","range":"10 mV až 100 mV","cmc":"0,10 % + 0,030 mV"},{"name":"10 Hz až 20 kHz","range":"100 mV až 1 V","cmc":"0,10 % + 0,30 mV"},{"name":"10 Hz až 20 kHz","range":"1 V až 10 V","cmc":"0,10 % + 3,0 mV"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement with a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement with a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 kHz od 10 mV do 100 mV CMC 0,10 % + 0,030 mV\n10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,30 mV\n10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 3,0 mV\nBezpośredni pomiar multimetrem wzorcowym","reference":"KP 02","norm_bases":["KP 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Generatory, kontrolery systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Bezpośredni pomiar multimetrem wzorcowym 10 Hz do 20 kHz od 10 mV do 100 mV CMC 0,10 % + 0,030 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,30 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 3,0 mV Střídavé napětí / Generátory, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 10 Hz až 20 kHz 10 mV až 100 mV CMC 0,10 % + 0,030 mV 10 Hz až 20 kHz 100 mV až 1 V CMC 0,10 % + 0,30 mV 10 Hz až 20 kHz 1 V až 10 V CMC 0,10 % + 3,0 mV KP 02 Napiecie przemienne / Generatory, kontrolery systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Bezposredni pomiar multimetrem wzorcowym 10 Hz do 20 kHz od 10 mV do 100 mV CMC 0,10 % + 0,030 mV 10 Hz do 20 kHz od 100 mV do 1 V CMC 0,10 % + 0,30 mV 10 Hz do 20 kHz od 1 V do 10 V CMC 0,10 % + 3,0 mV Stridave napeti / Generatory, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 10 Hz az 20 kHz 10 mV az 100 mV CMC 0,10 % + 0,030 mV 10 Hz az 20 kHz 100 mV az 1 V CMC 0,10 % + 0,30 mV 10 Hz az 20 kHz 1 V az 10 V CMC 0,10 % + 3,0 mV KP 02","search_en":"AC Voltage / Generators, controllers for vibration test systems Calibration – electrical quantities Direct measurement with a reference multimeter 10 Hz to 20 kHz 10 mV to 100 mV CMC 0,10 % + 0,030 mV 10 Hz to 20 kHz 100 mV to 1 V CMC 0,10 % + 0,30 mV 10 Hz to 20 kHz 1 V to 10 V CMC 0,10 % + 3,0 mV KP 02","search_zh":"交流电压 / 发生器、振动试验系统控制器 校准 – 电学量 用标准万用表直接测量 10 Hz 至 20 kHz 10 mV 至 100 mV CMC 0,10 % + 0,030 mV 10 Hz 至 20 kHz 100 mV 至 1 V CMC 0,10 % + 0,30 mV 10 Hz 至 20 kHz 1 V 至 10 V CMC 0,10 % + 3,0 mV KP 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"facc9405f828d0f5e470357c","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"1","test_object":"Częstościomierze – multimetry, analizatory sygnałów, wibrometry, liczniki, kontrolery VTS","test_object_en":"Frequency meters – multimeters, signal analyzers, vibrometers, counters, controllers for VTS","test_object_zh":"频率测量仪器 – 万用表、信号分析仪、测振仪、计数器、振动试验系统控制器","test_object_cs":"Měřidla frekvence – multimetry, signálové analyzátory, vibrometry, čítače, kontroléry VTS","methodology":"Wzorcowanie – częstotliwość","methodology_en":"Calibration – frequency","methodology_zh":"校准 – 频率","methodology_cs":"Kalibrace – frekvence","parameters":[{"name":"100 mV do 10 V","range":"od 3 Hz do 20 kHz","cmc":"0,015 % + 1 mHz"}],"parameters_en":[{"name":"100 mV to 10 V","range":"3 Hz to 20 kHz","cmc":"0,015 % + 1 mHz"}],"parameters_zh":[{"name":"100 mV 至 10 V","range":"3 Hz 至 20 kHz","cmc":"0,015 % + 1 mHz"}],"parameters_cs":[{"name":"100 mV až 10 V","range":"3 Hz až 20 kHz","cmc":"0,015 % + 1 mHz"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准万用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准万用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – częstotliwość\n100 mV do 10 V od 3 Hz do 20 kHz CMC 0,015 % + 1 mHz\nPorównanie z multimetrem wzorcowym","reference":"KP 02","norm_bases":["KP 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Frequency","regulatory_area_zh":"被测量领域的CMC：频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstościomierze – multimetry, analizatory sygnałów, wibrometry, liczniki, kontrolery VTS Wzorcowanie – częstotliwość Porównanie z multimetrem wzorcowym 100 mV do 10 V od 3 Hz do 20 kHz CMC 0,015 % + 1 mHz Měřidla frekvence – multimetry, signálové analyzátory, vibrometry, čítače, kontroléry VTS Kalibrace – frekvence Porovnání s etalonovým multimetrem 100 mV až 10 V 3 Hz až 20 kHz CMC 0,015 % + 1 mHz KP 02 Czestosciomierze – multimetry, analizatory sygnalow, wibrometry, liczniki, kontrolery VTS Wzorcowanie – czestotliwosc Porownanie z multimetrem wzorcowym 100 mV do 10 V od 3 Hz do 20 kHz CMC 0,015 % + 1 mHz Meridla frekvence – multimetry, signalove analyzatory, vibrometry, citace, kontrolery VTS Kalibrace – frekvence Porovnani s etalonovym multimetrem 100 mV az 10 V 3 Hz az 20 kHz CMC 0,015 % + 1 mHz KP 02","search_en":"Frequency meters – multimeters, signal analyzers, vibrometers, counters, controllers for VTS Calibration – frequency Comparison with a reference multimeter 100 mV to 10 V 3 Hz to 20 kHz CMC 0,015 % + 1 mHz KP 02","search_zh":"频率测量仪器 – 万用表、信号分析仪、测振仪、计数器、振动试验系统控制器 校准 – 频率 与标准万用表比较 100 mV 至 10 V 3 Hz 至 20 kHz CMC 0,015 % + 1 mHz KP 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b2b6211a3c62f06decbb66c","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"1","test_object":"Generatory częstotliwości – generatory, kontrolery VTS","test_object_en":"Frequency generators – generators, controllers for VTS","test_object_zh":"频率发生器 – 发生器、振动试验系统控制器","test_object_cs":"Generátory frekvence – generátory, kontroléry VTS","methodology":"Wzorcowanie – częstotliwość","methodology_en":"Calibration – frequency","methodology_zh":"校准 – 频率","methodology_cs":"Kalibrace – frekvence","parameters":[{"name":"100 mV do 10 V","range":"od 3 Hz do 20 kHz","cmc":"0,015 % + 1 mHz"}],"parameters_en":[{"name":"100 mV to 10 V","range":"3 Hz to 20 kHz","cmc":"0,015 % + 1 mHz"}],"parameters_zh":[{"name":"100 mV 至 10 V","range":"3 Hz 至 20 kHz","cmc":"0,015 % + 1 mHz"}],"parameters_cs":[{"name":"100 mV až 10 V","range":"3 Hz až 20 kHz","cmc":"0,015 % + 1 mHz"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym","technique_en":"Direct measurement with a reference multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Bezpośredni pomiar multimetrem wzorcowym"],"techniques_en":["Direct measurement with a reference multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – częstotliwość\n100 mV do 10 V od 3 Hz do 20 kHz CMC 0,015 % + 1 mHz\nBezpośredni pomiar multimetrem wzorcowym","reference":"KP 02","norm_bases":["KP 02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Frequency","regulatory_area_zh":"被测量领域的CMC：频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Generatory częstotliwości – generatory, kontrolery VTS Wzorcowanie – częstotliwość Bezpośredni pomiar multimetrem wzorcowym 100 mV do 10 V od 3 Hz do 20 kHz CMC 0,015 % + 1 mHz Generátory frekvence – generátory, kontroléry VTS Kalibrace – frekvence Přímé měření etalonovým multimetrem 100 mV až 10 V 3 Hz až 20 kHz CMC 0,015 % + 1 mHz KP 02 Generatory czestotliwosci – generatory, kontrolery VTS Wzorcowanie – czestotliwosc Bezposredni pomiar multimetrem wzorcowym 100 mV do 10 V od 3 Hz do 20 kHz CMC 0,015 % + 1 mHz Generatory frekvence – generatory, kontrolery VTS Kalibrace – frekvence Prime mereni etalonovym multimetrem 100 mV az 10 V 3 Hz az 20 kHz CMC 0,015 % + 1 mHz KP 02","search_en":"Frequency generators – generators, controllers for VTS Calibration – frequency Direct measurement with a reference multimeter 100 mV to 10 V 3 Hz to 20 kHz CMC 0,015 % + 1 mHz KP 02","search_zh":"频率发生器 – 发生器、振动试验系统控制器 校准 – 频率 用标准万用表直接测量 100 mV 至 10 V 3 Hz 至 20 kHz CMC 0,015 % + 1 mHz KP 02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5280d82772619964d039579d","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"1","test_object":"Czułość mikrofonu","test_object_en":"Microphone sensitivity","test_object_zh":"传声器灵敏度","test_object_cs":"Citlivost mikrofonu","methodology":"Wzorcowanie – wielkości akustyczne","methodology_en":"Calibration – acoustic quantities","methodology_zh":"校准 – 声学量","methodology_cs":"Kalibrace – akustické veličiny","parameters":[{"name":"10 Hz do 20 kHz","range":"od -90 dB (re 1V/Pa) do -20 dB (re 1V/Pa)","cmc":"0,07 dB"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"-90 dB (re 1V/Pa) to -20 dB (re 1V/Pa)","cmc":"0,07 dB"}],"parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"-90 dB (re 1V/Pa) 至 -20 dB (re 1V/Pa)","cmc":"0,07 dB"}],"parameters_cs":[{"name":"10 Hz až 20 kHz","range":"-90 dB (re 1V/Pa) až -20 dB (re 1V/Pa)","cmc":"0,07 dB"}],"technique":"Porównanie z mikrofonem wzorcowym","technique_en":"Comparison with a reference microphone","technique_zh":"与标准传声器比较","technique_cs":"Porovnání s etalonovým mikrofonem","techniques":["Porównanie z mikrofonem wzorcowym"],"techniques_en":["Comparison with a reference microphone"],"techniques_zh":["与标准传声器比较"],"techniques_cs":["Porovnání s etalonovým mikrofonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości akustyczne\n10 Hz do 20 kHz od -90 dB (re 1V/Pa) do -20 dB (re 1V/Pa) CMC 0,07 dB\nPorównanie z mikrofonem wzorcowym","reference":"KP 03 (ČSN EN 61094-5 ed.2, ČSN EN 61094-6)","norm_bases":["KP 03","ČSN EN 61094-5 ed.2","ČSN EN 61094-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości akustyczne","regulatory_area_en":"CMC for the field of measured quantity: Acoustic quantities","regulatory_area_zh":"被测量领域的CMC：声学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Akustické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czułość mikrofonu Wzorcowanie – wielkości akustyczne Porównanie z mikrofonem wzorcowym 10 Hz do 20 kHz od -90 dB (re 1V/Pa) do -20 dB (re 1V/Pa) CMC 0,07 dB Citlivost mikrofonu Kalibrace – akustické veličiny Porovnání s etalonovým mikrofonem 10 Hz až 20 kHz -90 dB (re 1V/Pa) až -20 dB (re 1V/Pa) CMC 0,07 dB KP 03 (ČSN EN 61094-5 ed.2, ČSN EN 61094-6) Czulosc mikrofonu Wzorcowanie – wielkosci akustyczne Porownanie z mikrofonem wzorcowym 10 Hz do 20 kHz od -90 dB (re 1V/Pa) do -20 dB (re 1V/Pa) CMC 0,07 dB Citlivost mikrofonu Kalibrace – akusticke veliciny Porovnani s etalonovym mikrofonem 10 Hz az 20 kHz -90 dB (re 1V/Pa) az -20 dB (re 1V/Pa) CMC 0,07 dB KP 03 (CSN EN 61094-5 ed.2, CSN EN 61094-6)","search_en":"Microphone sensitivity Calibration – acoustic quantities Comparison with a reference microphone 10 Hz to 20 kHz -90 dB (re 1V/Pa) to -20 dB (re 1V/Pa) CMC 0,07 dB KP 03 (ČSN EN 61094-5 ed.2, ČSN EN 61094-6)","search_zh":"传声器灵敏度 校准 – 声学量 与标准传声器比较 10 Hz 至 20 kHz -90 dB (re 1V/Pa) 至 -20 dB (re 1V/Pa) CMC 0,07 dB KP 03 (ČSN EN 61094-5 ed.2, ČSN EN 61094-6)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"696898d4ff2c3c96a0cc60fd","lab_id":"6ade8b46ff06824761708131","country":"CZ","accr_number":"2388","accr_body":"ČIA","row_label":"2","test_object":"Poziom ciśnienia akustycznego","test_object_en":"Sound pressure level","test_object_zh":"声压级","test_object_cs":"Hladina akustického tlaku","methodology":"Wzorcowanie – wielkości akustyczne","methodology_en":"Calibration – acoustic quantities","methodology_zh":"校准 – 声学量","methodology_cs":"Kalibrace – akustické veličiny","parameters":[{"name":"31,5 Hz do 16 kHz","range":"od 40 dB (re 20×10⁻⁶ Pa) do 140 dB (re 20×10⁻⁶ Pa)","cmc":"0,07 dB"}],"parameters_en":[{"name":"31,5 Hz to 16 kHz","range":"40 dB (re 20×10⁻⁶ Pa) to 140 dB (re 20×10⁻⁶ Pa)","cmc":"0,07 dB"}],"parameters_zh":[{"name":"31,5 Hz 至 16 kHz","range":"40 dB (re 20×10⁻⁶ Pa) 至 140 dB (re 20×10⁻⁶ Pa)","cmc":"0,07 dB"}],"parameters_cs":[{"name":"31,5 Hz až 16 kHz","range":"40 dB (re 20×10⁻⁶ Pa) až 140 dB (re 20×10⁻⁶ Pa)","cmc":"0,07 dB"}],"technique":"Pomiar bezpośredni mikrofonem wzorcowym / porównanie z kalibratorem wzorcowym","technique_en":"Direct measurement with a reference microphone / comparison with a reference calibrator","technique_zh":"用标准传声器直接测量 / 与标准校准器比较","technique_cs":"Přímé měření etalonovým mikrofonem / porovnání s etalonovým kalibrátorem","techniques":["Pomiar bezpośredni mikrofonem wzorcowym / porównanie z kalibratorem wzorcowym"],"techniques_en":["Direct measurement with a reference microphone / comparison with a reference calibrator"],"techniques_zh":["用标准传声器直接测量 / 与标准校准器比较"],"techniques_cs":["Přímé měření etalonovým mikrofonem / porovnání s etalonovým kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości akustyczne\n31,5 Hz do 16 kHz od 40 dB (re 20×10⁻⁶ Pa) do 140 dB (re 20×10⁻⁶ Pa) CMC 0,07 dB\nPomiar bezpośredni mikrofonem wzorcowym / porównanie z kalibratorem wzorcowym","reference":"KP 03 (ČSN EN IEC 60942 ed.2)","norm_bases":["KP 03","ČSN EN IEC 60942 ed.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości akustyczne","regulatory_area_en":"CMC for the field of measured quantity: Acoustic quantities","regulatory_area_zh":"被测量领域的CMC：声学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Akustické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Poziom ciśnienia akustycznego Wzorcowanie – wielkości akustyczne Pomiar bezpośredni mikrofonem wzorcowym / porównanie z kalibratorem wzorcowym 31,5 Hz do 16 kHz od 40 dB (re 20×10⁻⁶ Pa) do 140 dB (re 20×10⁻⁶ Pa) CMC 0,07 dB Hladina akustického tlaku Kalibrace – akustické veličiny Přímé měření etalonovým mikrofonem / porovnání s etalonovým kalibrátorem 31,5 Hz až 16 kHz 40 dB (re 20×10⁻⁶ Pa) až 140 dB (re 20×10⁻⁶ Pa) CMC 0,07 dB KP 03 (ČSN EN IEC 60942 ed.2) Poziom cisnienia akustycznego Wzorcowanie – wielkosci akustyczne Pomiar bezposredni mikrofonem wzorcowym / porownanie z kalibratorem wzorcowym 31,5 Hz do 16 kHz od 40 dB (re 20×10⁻⁶ Pa) do 140 dB (re 20×10⁻⁶ Pa) CMC 0,07 dB Hladina akustickeho tlaku Kalibrace – akusticke veliciny Prime mereni etalonovym mikrofonem / porovnani s etalonovym kalibratorem 31,5 Hz az 16 kHz 40 dB (re 20×10⁻⁶ Pa) az 140 dB (re 20×10⁻⁶ Pa) CMC 0,07 dB KP 03 (CSN EN IEC 60942 ed.2)","search_en":"Sound pressure level Calibration – acoustic quantities Direct measurement with a reference microphone / comparison with a reference calibrator 31,5 Hz to 16 kHz 40 dB (re 20×10⁻⁶ Pa) to 140 dB (re 20×10⁻⁶ Pa) CMC 0,07 dB KP 03 (ČSN EN IEC 60942 ed.2)","search_zh":"声压级 校准 – 声学量 用标准传声器直接测量 / 与标准校准器比较 31,5 Hz 至 16 kHz 40 dB (re 20×10⁻⁶ Pa) 至 140 dB (re 20×10⁻⁶ Pa) CMC 0,07 dB KP 03 (ČSN EN IEC 60942 ed.2)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}