{"lab":{"_id":"6ade8b45ff0682476170812f","country":"CZ","accr_number":"2386","accr_body":"ČIA","address":"Cejl 157/50, Zábrdovice, 602 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.622154,49.1985482]},"map_coord":[49.1985482,16.622154],"map_geo":"cai-mapa","methods_count":4,"name":"BMT Medical Technology s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: ciśnienie i temperatura.","search_text":"bmt medical technology s.r.o. cejl 157/50, zábrdovice, 602 00 brno 2386","source_page_url":"https://www.cai.cz/?subjekt=2386-bmt-medical-technology-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"18-05-2028","website":"www.bmt.cz","certificate_date":"18.09.2024","certificate_no":"485/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: ciśnienie i temperatura.","en":"Calibration in the fields of pressure and temperature.","zh":"压力和温度领域的校准。","cs":"Kalibrace v oborech tlak a teplota."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"fb9a0a2ebf43f24d52726888a8d163634eb06b71d4f04317cb84a618dd90e77a","source_pdf_url":"https://www.cai.cz/OA/pdf/P485_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P485_2024_EN.pdf"},"methods":[{"_id":"252c894b90034b5fde254008","lab_id":"6ade8b45ff0682476170812f","country":"CZ","accr_number":"2386","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze elektroniczne i tory pomiarowe ciśnienia","test_object_en":"Electronic pressure gauges and pressure measuring chains","test_object_zh":"电子压力表和压力测量链","test_object_cs":"Elektronické tlakoměry a měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"ciśnienie bezwzględne","range":"od 7 kPa do 400 kPa","cmc":"0,3 kPa"}],"parameters_en":[{"name":"absolute pressure","range":"7 kPa to 400 kPa","cmc":"0,3 kPa"}],"parameters_zh":[{"name":"绝对压力","range":"7 kPa 至 400 kPa","cmc":"0,3 kPa"}],"parameters_cs":[{"name":"absolutní tlak","range":"7 kPa až 400 kPa","cmc":"0,3 kPa"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital manometer","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým digitálním tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital manometer"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nciśnienie bezwzględne od 7 kPa do 400 kPa CMC 0,3 kPa\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"QPP 11-16, QPP 11-19","norm_bases":["QPP 11-16","QPP 11-19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze elektroniczne i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym ciśnienie bezwzględne od 7 kPa do 400 kPa CMC 0,3 kPa Elektronické tlakoměry a měřicí řetězce tlaku Kalibrace – tlak Porovnání s etalonovým digitálním tlakoměrem absolutní tlak 7 kPa až 400 kPa CMC 0,3 kPa QPP 11-16, QPP 11-19 Cisnieniomierze elektroniczne i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym cisnienie bezwzgledne od 7 kPa do 400 kPa CMC 0,3 kPa Elektronicke tlakomery a merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym digitalnim tlakomerem absolutni tlak 7 kPa az 400 kPa CMC 0,3 kPa QPP 11-16, QPP 11-19","search_en":"Electronic pressure gauges and pressure measuring chains Calibration – pressure Comparison with a standard digital manometer absolute pressure 7 kPa to 400 kPa CMC 0,3 kPa QPP 11-16, QPP 11-19","search_zh":"电子压力表和压力测量链 校准 – 压力 与标准数字压力表比较 绝对压力 7 kPa 至 400 kPa CMC 0,3 kPa QPP 11-16, QPP 11-19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9810c9fc7c6079f5db4f92a9","lab_id":"6ade8b45ff0682476170812f","country":"CZ","accr_number":"2386","accr_body":"ČIA","row_label":"2","test_object":"Ciśnieniomierze sprężyste","test_object_en":"Deformation pressure gauges","test_object_zh":"弹性式压力表","test_object_cs":"Deformační tlakoměry","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"nadciśnienie","range":"od -0,1 MPa do 0,5 MPa","cmc":"1,0 kPa"},{"name":"nadciśnienie","range":"od 0,5 MPa do 1,6 MPa","cmc":"5,0 kPa"}],"parameters_en":[{"name":"gauge pressure","range":"-0,1 MPa to 0,5 MPa","cmc":"1,0 kPa"},{"name":"gauge pressure","range":"0,5 MPa to 1,6 MPa","cmc":"5,0 kPa"}],"parameters_zh":[{"name":"表压","range":"-0,1 MPa 至 0,5 MPa","cmc":"1,0 kPa"},{"name":"表压","range":"0,5 MPa 至 1,6 MPa","cmc":"5,0 kPa"}],"parameters_cs":[{"name":"přetlak","range":"-0,1 MPa až 0,5 MPa","cmc":"1,0 kPa"},{"name":"přetlak","range":"0,5 MPa až 1,6 MPa","cmc":"5,0 kPa"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital manometer","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým digitálním tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital manometer"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nnadciśnienie od -0,1 MPa do 0,5 MPa CMC 1,0 kPa\nnadciśnienie od 0,5 MPa do 1,6 MPa CMC 5,0 kPa\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"QPP 11-23","norm_bases":["QPP 11-23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym nadciśnienie od -0,1 MPa do 0,5 MPa CMC 1,0 kPa nadciśnienie od 0,5 MPa do 1,6 MPa CMC 5,0 kPa Deformační tlakoměry Kalibrace – tlak Porovnání s etalonovým digitálním tlakoměrem přetlak -0,1 MPa až 0,5 MPa CMC 1,0 kPa přetlak 0,5 MPa až 1,6 MPa CMC 5,0 kPa QPP 11-23 Cisnieniomierze sprezyste Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym nadcisnienie od -0,1 MPa do 0,5 MPa CMC 1,0 kPa nadcisnienie od 0,5 MPa do 1,6 MPa CMC 5,0 kPa Deformacni tlakomery Kalibrace – tlak Porovnani s etalonovym digitalnim tlakomerem pretlak -0,1 MPa az 0,5 MPa CMC 1,0 kPa pretlak 0,5 MPa az 1,6 MPa CMC 5,0 kPa QPP 11-23","search_en":"Deformation pressure gauges Calibration – pressure Comparison with a standard digital manometer gauge pressure -0,1 MPa to 0,5 MPa CMC 1,0 kPa gauge pressure 0,5 MPa to 1,6 MPa CMC 5,0 kPa QPP 11-23","search_zh":"弹性式压力表 校准 – 压力 与标准数字压力表比较 表压 -0,1 MPa 至 0,5 MPa CMC 1,0 kPa 表压 0,5 MPa 至 1,6 MPa CMC 5,0 kPa QPP 11-23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7013f52939fe4457fe8b4a69","lab_id":"6ade8b45ff0682476170812f","country":"CZ","accr_number":"2386","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne i tory pomiarowe temperatury","test_object_en":"Electronic thermometers and temperature measuring chains","test_object_zh":"电子温度计和温度测量链","test_object_cs":"Elektronické teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 180 °C","cmc":"0,2 °C"},{"name":"","range":"od 180 °C do 250 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"0 °C to 180 °C","cmc":"0,2 °C"},{"name":"","range":"180 °C to 250 °C","cmc":"0,3 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 180 °C","cmc":"0,2 °C"},{"name":"","range":"180 °C 至 250 °C","cmc":"0,3 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 180 °C","cmc":"0,2 °C"},{"name":"","range":"180 °C až 250 °C","cmc":"0,3 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","technique_en":"Comparison with a standard digital thermometer in a liquid bath","technique_zh":"在液体槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard digital thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 0 °C do 180 °C CMC 0,2 °C\nod 180 °C do 250 °C CMC 0,3 °C\nPorównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej","reference":"QPP 11-16, QPP 11-18","norm_bases":["QPP 11-16","QPP 11-18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w łaźni cieczowej od 0 °C do 180 °C CMC 0,2 °C od 180 °C do 250 °C CMC 0,3 °C Elektronické teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kapalinové lázni 0 °C až 180 °C CMC 0,2 °C 180 °C až 250 °C CMC 0,3 °C QPP 11-16, QPP 11-18 Termometry elektroniczne i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w lazni cieczowej od 0 °C do 180 °C CMC 0,2 °C od 180 °C do 250 °C CMC 0,3 °C Elektronicke teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kapalinove lazni 0 °C az 180 °C CMC 0,2 °C 180 °C az 250 °C CMC 0,3 °C QPP 11-16, QPP 11-18","search_en":"Electronic thermometers and temperature measuring chains Calibration – temperature Comparison with a standard digital thermometer in a liquid bath 0 °C to 180 °C CMC 0,2 °C 180 °C to 250 °C CMC 0,3 °C QPP 11-16, QPP 11-18","search_zh":"电子温度计和温度测量链 校准 – 温度 在液体槽中与标准数字温度计比较 0 °C 至 180 °C CMC 0,2 °C 180 °C 至 250 °C CMC 0,3 °C QPP 11-16, QPP 11-18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"afefe2679d468ec7af50ee6f","lab_id":"6ade8b45ff0682476170812f","country":"CZ","accr_number":"2386","accr_body":"ČIA","row_label":"1","test_object":"Termometry elektroniczne i tory pomiarowe temperatury","test_object_en":"Electronic thermometers and temperature measuring chains","test_object_zh":"电子温度计和温度测量链","test_object_cs":"Elektronické teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 250 °C do 300 °C","cmc":"0,4 °C"}],"parameters_en":[{"name":"","range":"250 °C to 300 °C","cmc":"0,4 °C"}],"parameters_zh":[{"name":"","range":"250 °C 至 300 °C","cmc":"0,4 °C"}],"parameters_cs":[{"name":"","range":"250 °C až 300 °C","cmc":"0,4 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w piecyku","technique_en":"Comparison with a standard digital thermometer in a furnace","technique_zh":"在炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v pícce","techniques":["Porównanie z wzorcowym termometrem cyfrowym w piecyku"],"techniques_en":["Comparison with a standard digital thermometer in a furnace"],"techniques_zh":["在炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 250 °C do 300 °C CMC 0,4 °C\nPorównanie z wzorcowym termometrem cyfrowym w piecyku","reference":"QPP 11-16, QPP 11-18","norm_bases":["QPP 11-16","QPP 11-18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w piecyku od 250 °C do 300 °C CMC 0,4 °C Elektronické teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v pícce 250 °C až 300 °C CMC 0,4 °C QPP 11-16, QPP 11-18 Termometry elektroniczne i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w piecyku od 250 °C do 300 °C CMC 0,4 °C Elektronicke teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v picce 250 °C az 300 °C CMC 0,4 °C QPP 11-16, QPP 11-18","search_en":"Electronic thermometers and temperature measuring chains Calibration – temperature Comparison with a standard digital thermometer in a furnace 250 °C to 300 °C CMC 0,4 °C QPP 11-16, QPP 11-18","search_zh":"电子温度计和温度测量链 校准 – 温度 在炉中与标准数字温度计比较 250 °C 至 300 °C CMC 0,4 °C QPP 11-16, QPP 11-18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}