{"lab":{"_id":"6ade8b42ff0682476170812c","country":"CZ","accr_number":"2382","accr_body":"ČIA","address":"Kramolínská 955, Letňany, 199 00 Praha 9","categories":["metrology"],"city":"Praha 9","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.5241609,50.1375705]},"map_coord":[50.1375705,14.5241609],"map_geo":"cai-mapa","methods_count":2,"name":"Circulos Group s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie wielkości spektrofotometrycznych (UV-VIS), w zakresie określonym w załączniku do świadectwa.","search_text":"circulos group s.r.o. kramolínská 955, letňany, 199 00 praha 9 2382","source_page_url":"https://www.cai.cz/?subjekt=2382-circulos-group-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"12-05-2027","website":"www.techlab.bio","certificate_date":"16.02.2026","certificate_no":"81/2026","certificate_replaces":"348/2025 z 10.07.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie wielkości spektrofotometrycznych (UV-VIS), w zakresie określonym w załączniku do świadectwa.","en":"Calibration of spectrometric quantities (UV-VIS) to the extent as specified in the appendix to this Certificate.","zh":"分光光度量（UV-VIS）的校准，范围见本证书附件。","cs":"Kalibrace spektrofotometrických veličin (UV-VIS), vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące TechLab","lab_division_cs":"Kalibrační laboratoř TechLab","lab_division_en":"TechLab Calibration Laboratory","lab_division_zh":"TechLab 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"48411959a5af50ab543d4e1055307d57e98c23d2379bca71cac2b9059e2877bb","source_pdf_url":"https://www.cai.cz/OA/pdf/81_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/81_2026_EN.pdf"},"methods":[{"_id":"2972914965b440bad343f544","lab_id":"6ade8b42ff0682476170812c","country":"CZ","accr_number":"2382","accr_body":"ČIA","row_label":"1","test_object":"Absorbancja / spektrofotometry, kolorymetry, czytniki płytek","test_object_en":"Absorbance / spectrophotometers, colorimeters, plate readers","test_object_zh":"吸光度 / 分光光度计、比色计、酶标仪","test_object_cs":"Absorbance / spektrofotometry, kolorimetry, destičkové readery","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"VIS (440 do 635) nm","range":"od 0,2 do 1,1","cmc":"0,004 (abs.)"}],"parameters_en":[{"name":"VIS (440 to 635) nm","range":"0,2 to 1,1","cmc":"0,004 (abs.)"}],"parameters_zh":[{"name":"VIS（440 至 635）nm","range":"0,2 至 1,1","cmc":"0,004 (abs.)"}],"parameters_cs":[{"name":"VIS (440 až 635) nm","range":"0,2 až 1,1","cmc":"0,004 (abs.)"}],"technique":"Pomiar absorbancji spektrofotometrem i kolorymetrem","technique_en":"Measurement of absorbance by a spectrophotometer and colorimeter","technique_zh":"用分光光度计和比色计测量吸光度","technique_cs":"Měření absorbance spektrofotometrem a kolorimetrem","techniques":["Pomiar absorbancji spektrofotometrem i kolorymetrem"],"techniques_en":["Measurement of absorbance by a spectrophotometer and colorimeter"],"techniques_zh":["用分光光度计和比色计测量吸光度"],"techniques_cs":["Měření absorbance spektrofotometrem a kolorimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nVIS (440 do 635) nm od 0,2 do 1,1 CMC 0,004 (abs.)\nPomiar absorbancji spektrofotometrem i kolorymetrem","reference":"SOP-7-02","norm_bases":["SOP-7-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Absorbancja / spektrofotometry, kolorymetry, czytniki płytek Wzorcowanie – wielkości optyczne Pomiar absorbancji spektrofotometrem i kolorymetrem VIS (440 do 635) nm od 0,2 do 1,1 CMC 0,004 (abs.) Absorbance / spektrofotometry, kolorimetry, destičkové readery Kalibrace – optické veličiny Měření absorbance spektrofotometrem a kolorimetrem VIS (440 až 635) nm 0,2 až 1,1 CMC 0,004 (abs.) SOP-7-02 Absorbancja / spektrofotometry, kolorymetry, czytniki plytek Wzorcowanie – wielkosci optyczne Pomiar absorbancji spektrofotometrem i kolorymetrem VIS (440 do 635) nm od 0,2 do 1,1 CMC 0,004 (abs.) Absorbance / spektrofotometry, kolorimetry, destickove readery Kalibrace – opticke veliciny Mereni absorbance spektrofotometrem a kolorimetrem VIS (440 az 635) nm 0,2 az 1,1 CMC 0,004 (abs.) SOP-7-02","search_en":"Absorbance / spectrophotometers, colorimeters, plate readers Calibration – optical quantities Measurement of absorbance by a spectrophotometer and colorimeter VIS (440 to 635) nm 0,2 to 1,1 CMC 0,004 (abs.) SOP-7-02","search_zh":"吸光度 / 分光光度计、比色计、酶标仪 校准 – 光学量 用分光光度计和比色计测量吸光度 VIS（440 至 635）nm 0,2 至 1,1 CMC 0,004 (abs.) SOP-7-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b35a05024a5b5a3d1d0c8fb","lab_id":"6ade8b42ff0682476170812c","country":"CZ","accr_number":"2382","accr_body":"ČIA","row_label":"1","test_object":"Absorbancja / spektrofotometry, kolorymetry, czytniki płytek","test_object_en":"Absorbance / spectrophotometers, colorimeters, plate readers","test_object_zh":"吸光度 / 分光光度计、比色计、酶标仪","test_object_cs":"Absorbance / spektrofotometry, kolorimetry, destičkové readery","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"UV/VIS (405 do 750) nm","range":"od 0,1 do 3","cmc":"2,0 % + 0,02 (abs.)"}],"parameters_en":[{"name":"UV/VIS (405 to 750) nm","range":"0,1 to 3","cmc":"2,0 % + 0,02 (abs.)"}],"parameters_zh":[{"name":"UV/VIS（405 至 750）nm","range":"0,1 至 3","cmc":"2,0 % + 0,02 (abs.)"}],"parameters_cs":[{"name":"UV/VIS (405 až 750) nm","range":"0,1 až 3","cmc":"2,0 % + 0,02 (abs.)"}],"technique":"Pomiar absorbancji czytnikiem płytek","technique_en":"Measurement of absorbance by a plate reader","technique_zh":"用酶标仪测量吸光度","technique_cs":"Měření absorbance destičkovým readerem","techniques":["Pomiar absorbancji czytnikiem płytek"],"techniques_en":["Measurement of absorbance by a plate reader"],"techniques_zh":["用酶标仪测量吸光度"],"techniques_cs":["Měření absorbance destičkovým readerem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nUV/VIS (405 do 750) nm od 0,1 do 3 CMC 2,0 % + 0,02 (abs.)\nPomiar absorbancji czytnikiem płytek","reference":"SOP-7-02","norm_bases":["SOP-7-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Absorbancja / spektrofotometry, kolorymetry, czytniki płytek Wzorcowanie – wielkości optyczne Pomiar absorbancji czytnikiem płytek UV/VIS (405 do 750) nm od 0,1 do 3 CMC 2,0 % + 0,02 (abs.) Absorbance / spektrofotometry, kolorimetry, destičkové readery Kalibrace – optické veličiny Měření absorbance destičkovým readerem UV/VIS (405 až 750) nm 0,1 až 3 CMC 2,0 % + 0,02 (abs.) SOP-7-02 Absorbancja / spektrofotometry, kolorymetry, czytniki plytek Wzorcowanie – wielkosci optyczne Pomiar absorbancji czytnikiem plytek UV/VIS (405 do 750) nm od 0,1 do 3 CMC 2,0 % + 0,02 (abs.) Absorbance / spektrofotometry, kolorimetry, destickove readery Kalibrace – opticke veliciny Mereni absorbance destickovym readerem UV/VIS (405 az 750) nm 0,1 az 3 CMC 2,0 % + 0,02 (abs.) SOP-7-02","search_en":"Absorbance / spectrophotometers, colorimeters, plate readers Calibration – optical quantities Measurement of absorbance by a plate reader UV/VIS (405 to 750) nm 0,1 to 3 CMC 2,0 % + 0,02 (abs.) SOP-7-02","search_zh":"吸光度 / 分光光度计、比色计、酶标仪 校准 – 光学量 用酶标仪测量吸光度 UV/VIS（405 至 750）nm 0,1 至 3 CMC 2,0 % + 0,02 (abs.) SOP-7-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}