{"lab":{"_id":"6ade8b41ff06824761708129","country":"CZ","accr_number":"2377","accr_body":"ČIA","address":"Západní 93, 251 01 Čestlice","categories":["metrology"],"city":"Čestlice","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.582985,50.0072888]},"map_coord":[50.0072888,14.582985],"map_geo":"cai-mapa","methods_count":2,"name":"TRIGON PLUS s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie: temperatura.","search_text":"trigon plus s.r.o. západní 93, 251 01 čestlice 2377","source_page_url":"https://www.cai.cz/?subjekt=2377-trigon-plus-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"09-02-2028","website":"www.trigonplus.cz","certificate_date":"09.02.2023","certificate_no":"64/2023","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie: temperatura.","en":"Calibration in the field of temperature.","zh":"温度领域的校准。","cs":"Kalibrace v oboru teplota."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"TRIGON PLUS, laboratorium wzorcujące","lab_division_cs":"TRIGON PLUS, kalibrační laboratoř","lab_division_en":"TRIGON PLUS, Calibration Laboratory","lab_division_zh":"TRIGON PLUS 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"ee4761508901ab29493f7f714264af1418808139d993dc0ee5727b6f458febec","source_pdf_url":"https://www.cai.cz/OA/pdf/P64_2023_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P64_2023_EN.pdf"},"methods":[{"_id":"90752c4bfea4003c879ec3fa","lab_id":"6ade8b41ff06824761708129","country":"CZ","accr_number":"2377","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indication thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -60 °C","cmc":"0,49 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -60 °C","cmc":"0,49 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -60 °C","cmc":"0,49 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -60 °C","cmc":"0,49 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w zamrażarce","technique_en":"Comparison with a reference digital thermometer in a freezer box","technique_zh":"在冷冻箱中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým číslicovým teploměrem v mrazicím boxu","techniques":["Porównanie z wzorcowym termometrem cyfrowym w zamrażarce"],"techniques_en":["Comparison with a reference digital thermometer in a freezer box"],"techniques_zh":["在冷冻箱中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým číslicovým teploměrem v mrazicím boxu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -80 °C do -60 °C CMC 0,49 °C\nPorównanie z wzorcowym termometrem cyfrowym w zamrażarce","reference":"KL-PP-01","norm_bases":["KL-PP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w zamrażarce od -80 °C do -60 °C CMC 0,49 °C Indikační teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým číslicovým teploměrem v mrazicím boxu -80 °C až -60 °C CMC 0,49 °C KL-PP-01 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w zamrazarce od -80 °C do -60 °C CMC 0,49 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym cislicovym teplomerem v mrazicim boxu -80 °C az -60 °C CMC 0,49 °C KL-PP-01","search_en":"Indication thermometers and temperature measuring chains Calibration – temperature Comparison with a reference digital thermometer in a freezer box -80 °C to -60 °C CMC 0,49 °C KL-PP-01","search_zh":"指示式温度计和温度测量链 校准 – 温度 在冷冻箱中与标准数字温度计比较 -80 °C 至 -60 °C CMC 0,49 °C KL-PP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fa476eb72478cff8ee992933","lab_id":"6ade8b41ff06824761708129","country":"CZ","accr_number":"2377","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indication thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -60 °C do -20 °C","cmc":"0,27 °C"},{"name":"","range":"od -20 °C do 60 °C","cmc":"0,13 °C"}],"parameters_en":[{"name":"","range":"-60 °C to -20 °C","cmc":"0,27 °C"},{"name":"","range":"-20 °C to 60 °C","cmc":"0,13 °C"}],"parameters_zh":[{"name":"","range":"-60 °C 至 -20 °C","cmc":"0,27 °C"},{"name":"","range":"-20 °C 至 60 °C","cmc":"0,13 °C"}],"parameters_cs":[{"name":"","range":"-60 °C až -20 °C","cmc":"0,27 °C"},{"name":"","range":"-20 °C až 60 °C","cmc":"0,13 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w łaźni termostatycznej","technique_en":"Comparison with reference digital thermometer in thermostatic bath","technique_zh":"在恒温槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým číslicovým teploměrem v termostatické lázni","techniques":["Porównanie z wzorcowym termometrem cyfrowym w łaźni termostatycznej"],"techniques_en":["Comparison with reference digital thermometer in thermostatic bath"],"techniques_zh":["在恒温槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým číslicovým teploměrem v termostatické lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -60 °C do -20 °C CMC 0,27 °C\nod -20 °C do 60 °C CMC 0,13 °C\nPorównanie z wzorcowym termometrem cyfrowym w łaźni termostatycznej","reference":"KL-PP-01","norm_bases":["KL-PP-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w łaźni termostatycznej od -60 °C do -20 °C CMC 0,27 °C od -20 °C do 60 °C CMC 0,13 °C Indikační teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým číslicovým teploměrem v termostatické lázni -60 °C až -20 °C CMC 0,27 °C -20 °C až 60 °C CMC 0,13 °C KL-PP-01 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w lazni termostatycznej od -60 °C do -20 °C CMC 0,27 °C od -20 °C do 60 °C CMC 0,13 °C Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym cislicovym teplomerem v termostaticke lazni -60 °C az -20 °C CMC 0,27 °C -20 °C az 60 °C CMC 0,13 °C KL-PP-01","search_en":"Indication thermometers and temperature measuring chains Calibration – temperature Comparison with reference digital thermometer in thermostatic bath -60 °C to -20 °C CMC 0,27 °C -20 °C to 60 °C CMC 0,13 °C KL-PP-01","search_zh":"指示式温度计和温度测量链 校准 – 温度 在恒温槽中与标准数字温度计比较 -60 °C 至 -20 °C CMC 0,27 °C -20 °C 至 60 °C CMC 0,13 °C KL-PP-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}