{"lab":{"_id":"6acfffecff06824761705e1b","accr_number":"2375","country":"CZ","accr_body":"ČIA","address":"Tř. Budovatelů 2531, 434 01 Most","categories":["metrology"],"city":"Most","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[13.6442943,50.511199]},"map_coord":[50.511199,13.6442943],"map_geo":"cai-mapa","methods_count":3,"name":"CTS-Kalibr s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie temperatury i wilgotności powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"cts-kalibr s.r.o. tř. budovatelů 2531, 434 01 most 2375","source_page_url":"https://www.cai.cz/?subjekt=2375-cts-kalibr-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"13-11-2030","website":"www.ctskalibr.cz","certificate_date":"13.11.2025","certificate_no":"585/2025","certificate_replaces":"716/2020 z 26.11.2020","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie temperatury i wilgotności powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of air temperature and humidity to the extent as specified in the appendix to this Certificate.","zh":"空气温度和湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru teplota a vlhkost vzduchu, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"CTS-Kalibr – laboratorium wzorcujące","lab_division_cs":"CTS-Kalibr, kalibrační laboratoř","lab_division_en":"CTS-Kalibr, Calibration Laboratory","lab_division_zh":"CTS-Kalibr 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników wzorcowań.","en":"The laboratory provides opinions and interpretations of the calibration results.","zh":"实验室提供校准结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků kalibrací."}],"source_lang":"cs","source_pdf_sha256":"7bd82a56b222ced7bb02786a1c063917bbe095f2277b475ce274a0ae5d1ceb9c","source_pdf_url":"https://www.cai.cz/OA/pdf/585_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/585_2025_EN.pdf"},"methods":[{"_id":"db334d3404beb5a5a77b1aed","lab_id":"6acfffecff06824761705e1b","country":"CZ","accr_number":"2375","accr_body":"ČIA","row_label":"1","test_object":"Tory pomiarowe temperatury, w tym termometry komór termicznych i klimatycznych, oraz charakteryzacja komór termicznych","test_object_en":"Temperature measuring chains, including thermometers for thermal and climatic chambers, and characterization of thermal chambers","test_object_zh":"温度测量链，包括热箱和气候箱的温度计，以及热箱的特性测定","test_object_cs":"Měřicí řetězce teploty včetně teploměrů teplotních a klimatických komor a charakterizace teplotních komor","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -70 °C do -40 °C","cmc":"0,26 °C"},{"name":"","range":"od -40 °C do 180 °C","cmc":"0,20 °C"},{"name":"","range":"od 180 °C do 300 °C","cmc":"0,34 °C"},{"name":"","range":"od 300 °C do 600 °C","cmc":"1,9 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"2,2 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"2,5 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"3,2 °C"}],"parameters_en":[{"name":"","range":"-70 °C to -40 °C","cmc":"0,26 °C"},{"name":"","range":"-40 °C to 180 °C","cmc":"0,20 °C"},{"name":"","range":"180 °C to 300 °C","cmc":"0,34 °C"},{"name":"","range":"300 °C to 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C to 800 °C","cmc":"2,2 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"2,5 °C"},{"name":"","range":"1000 °C to 1200 °C","cmc":"3,2 °C"}],"parameters_zh":[{"name":"","range":"-70 °C 至 -40 °C","cmc":"0,26 °C"},{"name":"","range":"-40 °C 至 180 °C","cmc":"0,20 °C"},{"name":"","range":"180 °C 至 300 °C","cmc":"0,34 °C"},{"name":"","range":"300 °C 至 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"2,2 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"2,5 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"3,2 °C"}],"parameters_cs":[{"name":"","range":"-70 °C až -40 °C","cmc":"0,26 °C"},{"name":"","range":"-40 °C až 180 °C","cmc":"0,20 °C"},{"name":"","range":"180 °C až 300 °C","cmc":"0,34 °C"},{"name":"","range":"300 °C až 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"2,2 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"2,5 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"3,2 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym w przestrzeni roboczej urządzenia","technique_en":"Comparison with a reference digital thermometer in the test space of the device","technique_zh":"在设备试验空间内与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem ve zkušebním prostoru zařízení","techniques":["Porównanie z cyfrowym termometrem wzorcowym w przestrzeni roboczej urządzenia"],"techniques_en":["Comparison with a reference digital thermometer in the test space of the device"],"techniques_zh":["在设备试验空间内与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem ve zkušebním prostoru zařízení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -70 °C do -40 °C CMC 0,26 °C\nod -40 °C do 180 °C CMC 0,20 °C\nod 180 °C do 300 °C CMC 0,34 °C\nod 300 °C do 600 °C CMC 1,9 °C\nod 600 °C do 800 °C CMC 2,2 °C\nod 800 °C do 1000 °C CMC 2,5 °C\nod 1000 °C do 1200 °C CMC 3,2 °C\nPorównanie z cyfrowym termometrem wzorcowym w przestrzeni roboczej urządzenia","reference":"KP01","norm_bases":["KP01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe temperatury, w tym termometry komór termicznych i klimatycznych, oraz charakteryzacja komór termicznych Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym w przestrzeni roboczej urządzenia od -70 °C do -40 °C CMC 0,26 °C od -40 °C do 180 °C CMC 0,20 °C od 180 °C do 300 °C CMC 0,34 °C od 300 °C do 600 °C CMC 1,9 °C od 600 °C do 800 °C CMC 2,2 °C od 800 °C do 1000 °C CMC 2,5 °C od 1000 °C do 1200 °C CMC 3,2 °C Měřicí řetězce teploty včetně teploměrů teplotních a klimatických komor a charakterizace teplotních komor Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem ve zkušebním prostoru zařízení -70 °C až -40 °C CMC 0,26 °C -40 °C až 180 °C CMC 0,20 °C 180 °C až 300 °C CMC 0,34 °C 300 °C až 600 °C CMC 1,9 °C 600 °C až 800 °C CMC 2,2 °C 800 °C až 1000 °C CMC 2,5 °C 1000 °C až 1200 °C CMC 3,2 °C KP01 Tory pomiarowe temperatury, w tym termometry komor termicznych i klimatycznych, oraz charakteryzacja komor termicznych Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym w przestrzeni roboczej urzadzenia od -70 °C do -40 °C CMC 0,26 °C od -40 °C do 180 °C CMC 0,20 °C od 180 °C do 300 °C CMC 0,34 °C od 300 °C do 600 °C CMC 1,9 °C od 600 °C do 800 °C CMC 2,2 °C od 800 °C do 1000 °C CMC 2,5 °C od 1000 °C do 1200 °C CMC 3,2 °C Merici retezce teploty vcetne teplomeru teplotnich a klimatickych komor a charakterizace teplotnich komor Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem ve zkusebnim prostoru zarizeni -70 °C az -40 °C CMC 0,26 °C -40 °C az 180 °C CMC 0,20 °C 180 °C az 300 °C CMC 0,34 °C 300 °C az 600 °C CMC 1,9 °C 600 °C az 800 °C CMC 2,2 °C 800 °C az 1000 °C CMC 2,5 °C 1000 °C az 1200 °C CMC 3,2 °C KP01","search_en":"Temperature measuring chains, including thermometers for thermal and climatic chambers, and characterization of thermal chambers Calibration – temperature Comparison with a reference digital thermometer in the test space of the device -70 °C to -40 °C CMC 0,26 °C -40 °C to 180 °C CMC 0,20 °C 180 °C to 300 °C CMC 0,34 °C 300 °C to 600 °C CMC 1,9 °C 600 °C to 800 °C CMC 2,2 °C 800 °C to 1000 °C CMC 2,5 °C 1000 °C to 1200 °C CMC 3,2 °C KP01","search_zh":"温度测量链，包括热箱和气候箱的温度计，以及热箱的特性测定 校准 – 温度 在设备试验空间内与标准数字温度计比较 -70 °C 至 -40 °C CMC 0,26 °C -40 °C 至 180 °C CMC 0,20 °C 180 °C 至 300 °C CMC 0,34 °C 300 °C 至 600 °C CMC 1,9 °C 600 °C 至 800 °C CMC 2,2 °C 800 °C 至 1000 °C CMC 2,5 °C 1000 °C 至 1200 °C CMC 3,2 °C KP01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5c6216a9f8d8be1ced7a4af7","lab_id":"6acfffecff06824761705e1b","country":"CZ","accr_number":"2375","accr_body":"ČIA","row_label":"2","test_object":"Termometry o odczycie bezpośrednim","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 100 °C","cmc":"0,17 °C"},{"name":"","range":"od 100 °C do 150 °C","cmc":"0,19 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 100 °C","cmc":"0,17 °C"},{"name":"","range":"100 °C to 150 °C","cmc":"0,19 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 100 °C","cmc":"0,17 °C"},{"name":"","range":"100 °C 至 150 °C","cmc":"0,19 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 100 °C","cmc":"0,17 °C"},{"name":"","range":"100 °C až 150 °C","cmc":"0,19 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym","technique_en":"Comparison with a reference digital thermometer in a calibrating oven","technique_zh":"在校准炉中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kalibrační pícce","techniques":["Porównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym"],"techniques_en":["Comparison with a reference digital thermometer in a calibrating oven"],"techniques_zh":["在校准炉中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 100 °C CMC 0,17 °C\nod 100 °C do 150 °C CMC 0,19 °C\nPorównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym","reference":"KP01","norm_bases":["KP01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry o odczycie bezpośrednim Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym w piecu wzorcującym od -30 °C do 100 °C CMC 0,17 °C od 100 °C do 150 °C CMC 0,19 °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kalibrační pícce -30 °C až 100 °C CMC 0,17 °C 100 °C až 150 °C CMC 0,19 °C KP01 Termometry o odczycie bezposrednim Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym w piecu wzorcujacym od -30 °C do 100 °C CMC 0,17 °C od 100 °C do 150 °C CMC 0,19 °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kalibracni picce -30 °C az 100 °C CMC 0,17 °C 100 °C az 150 °C CMC 0,19 °C KP01","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference digital thermometer in a calibrating oven -30 °C to 100 °C CMC 0,17 °C 100 °C to 150 °C CMC 0,19 °C KP01","search_zh":"直读式温度计 校准 – 温度 在校准炉中与标准数字温度计比较 -30 °C 至 100 °C CMC 0,17 °C 100 °C 至 150 °C CMC 0,19 °C KP01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c5956ac8fda84212b8d27c86","lab_id":"6acfffecff06824761705e1b","country":"CZ","accr_number":"2375","accr_body":"ČIA","row_label":"1","test_object":"Wilgotnościomierze powietrza i tory pomiarowe wilgotności, w tym komory klimatyczne","test_object_en":"Air humidity meters and humidity measuring chains, including climatic chambers","test_object_zh":"空气湿度计和湿度测量链，包括气候箱","test_object_cs":"Vlhkoměry vzduchu a měřicí řetězce vlhkosti včetně klimatických komor","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"Temperatura powietrza (10 do 40) °C","range":"od 10 % RH do 50 % RH","cmc":"1,9 % RH"},{"name":"(40 do 80) °C","range":"od 10 % RH do 50 % RH","cmc":"2,0 % RH"},{"name":"(10 do 40) °C","range":"od 50 % RH do 95 % RH","cmc":"2,2 % RH"},{"name":"(40 do 80) °C","range":"od 50 % RH do 95 % RH","cmc":"2,3 % RH"}],"parameters_en":[{"name":"Air temperature (10 to 40) °C","range":"10 % RH to 50 % RH","cmc":"1,9 % RH"},{"name":"(40 to 80) °C","range":"10 % RH to 50 % RH","cmc":"2,0 % RH"},{"name":"(10 to 40) °C","range":"50 % RH to 95 % RH","cmc":"2,2 % RH"},{"name":"(40 to 80) °C","range":"50 % RH to 95 % RH","cmc":"2,3 % RH"}],"parameters_zh":[{"name":"空气温度 (10 至 40) °C","range":"10 % RH 至 50 % RH","cmc":"1,9 % RH"},{"name":"(40 至 80) °C","range":"10 % RH 至 50 % RH","cmc":"2,0 % RH"},{"name":"(10 至 40) °C","range":"50 % RH 至 95 % RH","cmc":"2,2 % RH"},{"name":"(40 至 80) °C","range":"50 % RH 至 95 % RH","cmc":"2,3 % RH"}],"parameters_cs":[{"name":"Teplota vzduchu (10 až 40) °C","range":"10 % RH až 50 % RH","cmc":"1,9 % RH"},{"name":"(40 až 80) °C","range":"10 % RH až 50 % RH","cmc":"2,0 % RH"},{"name":"(10 až 40) °C","range":"50 % RH až 95 % RH","cmc":"2,2 % RH"},{"name":"(40 až 80) °C","range":"50 % RH až 95 % RH","cmc":"2,3 % RH"}],"technique":"Porównanie z pojemnościowym wilgotnościomierzem wzorcowym w przestrzeni roboczej urządzenia","technique_en":"Comparison with a reference capacitive humidity meter in the test space of the device","technique_zh":"在设备试验空间内与标准电容式湿度计比较","technique_cs":"Porovnání s etalonovým kapacitním vlhkoměrem ve zkušebním prostoru zařízení","techniques":["Porównanie z pojemnościowym wilgotnościomierzem wzorcowym w przestrzeni roboczej urządzenia"],"techniques_en":["Comparison with a reference capacitive humidity meter in the test space of the device"],"techniques_zh":["在设备试验空间内与标准电容式湿度计比较"],"techniques_cs":["Porovnání s etalonovým kapacitním vlhkoměrem ve zkušebním prostoru zařízení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\nTemperatura powietrza (10 do 40) °C od 10 % RH do 50 % RH CMC 1,9 % RH\n(40 do 80) °C od 10 % RH do 50 % RH CMC 2,0 % RH\n(10 do 40) °C od 50 % RH do 95 % RH CMC 2,2 % RH\n(40 do 80) °C od 50 % RH do 95 % RH CMC 2,3 % RH\nPorównanie z pojemnościowym wilgotnościomierzem wzorcowym w przestrzeni roboczej urządzenia","reference":"KP02","norm_bases":["KP02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotnościomierze powietrza i tory pomiarowe wilgotności, w tym komory klimatyczne Wzorcowanie – wilgotność powietrza Porównanie z pojemnościowym wilgotnościomierzem wzorcowym w przestrzeni roboczej urządzenia Temperatura powietrza (10 do 40) °C od 10 % RH do 50 % RH CMC 1,9 % RH (40 do 80) °C od 10 % RH do 50 % RH CMC 2,0 % RH (10 do 40) °C od 50 % RH do 95 % RH CMC 2,2 % RH (40 do 80) °C od 50 % RH do 95 % RH CMC 2,3 % RH Vlhkoměry vzduchu a měřicí řetězce vlhkosti včetně klimatických komor Kalibrace – vlhkost vzduchu Porovnání s etalonovým kapacitním vlhkoměrem ve zkušebním prostoru zařízení Teplota vzduchu (10 až 40) °C 10 % RH až 50 % RH CMC 1,9 % RH (40 až 80) °C 10 % RH až 50 % RH CMC 2,0 % RH (10 až 40) °C 50 % RH až 95 % RH CMC 2,2 % RH (40 až 80) °C 50 % RH až 95 % RH CMC 2,3 % RH KP02 Wilgotnosciomierze powietrza i tory pomiarowe wilgotnosci, w tym komory klimatyczne Wzorcowanie – wilgotnosc powietrza Porownanie z pojemnosciowym wilgotnosciomierzem wzorcowym w przestrzeni roboczej urzadzenia Temperatura powietrza (10 do 40) °C od 10 % RH do 50 % RH CMC 1,9 % RH (40 do 80) °C od 10 % RH do 50 % RH CMC 2,0 % RH (10 do 40) °C od 50 % RH do 95 % RH CMC 2,2 % RH (40 do 80) °C od 50 % RH do 95 % RH CMC 2,3 % RH Vlhkomery vzduchu a merici retezce vlhkosti vcetne klimatickych komor Kalibrace – vlhkost vzduchu Porovnani s etalonovym kapacitnim vlhkomerem ve zkusebnim prostoru zarizeni Teplota vzduchu (10 az 40) °C 10 % RH az 50 % RH CMC 1,9 % RH (40 az 80) °C 10 % RH az 50 % RH CMC 2,0 % RH (10 az 40) °C 50 % RH az 95 % RH CMC 2,2 % RH (40 az 80) °C 50 % RH az 95 % RH CMC 2,3 % RH KP02","search_en":"Air humidity meters and humidity measuring chains, including climatic chambers Calibration – air humidity Comparison with a reference capacitive humidity meter in the test space of the device Air temperature (10 to 40) °C 10 % RH to 50 % RH CMC 1,9 % RH (40 to 80) °C 10 % RH to 50 % RH CMC 2,0 % RH (10 to 40) °C 50 % RH to 95 % RH CMC 2,2 % RH (40 to 80) °C 50 % RH to 95 % RH CMC 2,3 % RH KP02","search_zh":"空气湿度计和湿度测量链，包括气候箱 校准 – 空气湿度 在设备试验空间内与标准电容式湿度计比较 空气温度 (10 至 40) °C 10 % RH 至 50 % RH CMC 1,9 % RH (40 至 80) °C 10 % RH 至 50 % RH CMC 2,0 % RH (10 至 40) °C 50 % RH 至 95 % RH CMC 2,2 % RH (40 至 80) °C 50 % RH 至 95 % RH CMC 2,3 % RH KP02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}