{"lab":{"_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","address":"Gellhornova 2231/4, 678 01 Blansko","categories":["metrology"],"city":"Blansko","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.6548366,49.3491072]},"map_coord":[49.3491072,16.6548366],"map_geo":"cai-mapa","methods_count":7,"name":"HOLAB, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ruch mechaniczny, temperatura, wielkości elektryczne, częstotliwość i wilgotność.","search_text":"holab, spol. s r.o. gellhornova 2231/4, 678 01 blansko 2358","source_page_url":"https://www.cai.cz/?subjekt=2358-holab-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"22-05-2028","website":"www.holab.cz","certificate_date":"28.12.2023","certificate_no":"699/2023","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinach: ruch mechaniczny, temperatura, wielkości elektryczne, częstotliwość i wilgotność.","en":"Calibration of measuring instruments in the fields of mechanical motion, temperature, electrical quantities, frequency and humidity.","zh":"机械运动、温度、电学量、频率和湿度领域测量器具的校准。","cs":"Kalibrace měřidel v oborech mechanický pohyb, teplota, elektrické veličiny, frekvence a vlhkost."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"9c367d2b8ad76ae8dde7eb5b4f2debf6a765815196ad8c03afea2e53b8bc9b2b","source_pdf_url":"https://www.cai.cz/OA/pdf/P699_2023_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P699_2023_EN.pdf"},"methods":[{"_id":"dcc3ea3f00067e0d1739c179","lab_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","row_label":"1","test_object":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / wzorce drgań i systemy do badań wibracyjnych, wibrometry z przetwornikiem","test_object_en":"Acceleration of rectilinear mechanical vibrations of harmonic waveform / vibration standards and vibration test systems, vibrometers with a sensor","test_object_zh":"简谐直线机械振动加速度 / 振动标准器和振动试验系统、带传感器的测振仪","test_object_cs":"Zrychlení přímočarých mechanických vibrací harmonického průběhu / etalony vibrací a vibrační testovací systémy, vibrometry se snímačem","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"7 Hz do 10 Hz","range":"od 0,10 m s⁻² do 200 m s⁻²","cmc":"2,0 %"},{"name":"10 Hz do 100 Hz","range":"od 0,10 m s⁻² do 200 m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"od 0,10 m s⁻² do 200 m s⁻²","cmc":"1,0 %"},{"name":"100 Hz do 920 Hz","range":"od 0,10 m s⁻² do 200 m s⁻²","cmc":"1,2 %"},{"name":"920 Hz do 5 kHz","range":"od 0,10 m s⁻² do 200 m s⁻²","cmc":"1,6 %"},{"name":"5 kHz do 10 kHz","range":"od 0,10 m s⁻² do 200 m s⁻²","cmc":"2,0 %"}],"parameters_en":[{"name":"7 Hz to 10 Hz","range":"0,10 m s⁻² to 200 m s⁻²","cmc":"2,0 %"},{"name":"10 Hz to 100 Hz","range":"0,10 m s⁻² to 200 m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 m s⁻² to 200 m s⁻²","cmc":"1,0 %"},{"name":"100 Hz to 920 Hz","range":"0,10 m s⁻² to 200 m s⁻²","cmc":"1,2 %"},{"name":"920 Hz to 5 kHz","range":"0,10 m s⁻² to 200 m s⁻²","cmc":"1,6 %"},{"name":"5 kHz to 10 kHz","range":"0,10 m s⁻² to 200 m s⁻²","cmc":"2,0 %"}],"parameters_zh":[{"name":"7 Hz 至 10 Hz","range":"0,10 m s⁻² 至 200 m s⁻²","cmc":"2,0 %"},{"name":"10 Hz 至 100 Hz","range":"0,10 m s⁻² 至 200 m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 m s⁻² 至 200 m s⁻²","cmc":"1,0 %"},{"name":"100 Hz 至 920 Hz","range":"0,10 m s⁻² 至 200 m s⁻²","cmc":"1,2 %"},{"name":"920 Hz 至 5 kHz","range":"0,10 m s⁻² 至 200 m s⁻²","cmc":"1,6 %"},{"name":"5 kHz 至 10 kHz","range":"0,10 m s⁻² 至 200 m s⁻²","cmc":"2,0 %"}],"parameters_cs":[{"name":"7 Hz až 10 Hz","range":"0,10 m s⁻² až 200 m s⁻²","cmc":"2,0 %"},{"name":"10 Hz až 100 Hz","range":"0,10 m s⁻² až 200 m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 m s⁻² až 200 m s⁻²","cmc":"1,0 %"},{"name":"100 Hz až 920 Hz","range":"0,10 m s⁻² až 200 m s⁻²","cmc":"1,2 %"},{"name":"920 Hz až 5 kHz","range":"0,10 m s⁻² až 200 m s⁻²","cmc":"1,6 %"},{"name":"5 kHz až 10 kHz","range":"0,10 m s⁻² až 200 m s⁻²","cmc":"2,0 %"}],"technique":"Porównanie z przetwornikiem wzorcowym","technique_en":"Comparison with a reference sensor","technique_zh":"与标准传感器比较","technique_cs":"Porovnání s etalonovým snímačem","techniques":["Porównanie z przetwornikiem wzorcowym"],"techniques_en":["Comparison with a reference sensor"],"techniques_zh":["与标准传感器比较"],"techniques_cs":["Porovnání s etalonovým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n7 Hz do 10 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 2,0 %\n10 Hz do 100 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,4 %\n100 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,0 %\n100 Hz do 920 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,2 %\n920 Hz do 5 kHz od 0,10 m s⁻² do 200 m s⁻² CMC 1,6 %\n5 kHz do 10 kHz od 0,10 m s⁻² do 200 m s⁻² CMC 2,0 %\nPorównanie z przetwornikiem wzorcowym","reference":"KP 2.22 (ČSN ISO 16063-21)","norm_bases":["KP 2.22","ČSN ISO 16063-21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":"Przyspieszenie można podawać także w jednostkach g (przyspieszenie ziemskie), czułość przetworników w pC/g lub mV/g, przy 1 g = 9,80665 m s⁻².","note_en":"Acceleration can also be specified in g units (gravitational acceleration), sensitivity of the sensors in pC/g or mV/g, for 1 g = 9,80665 m s⁻².","note_zh":"加速度也可用 g（重力加速度）单位表示，传感器灵敏度可用 pC/g 或 mV/g 表示，1 g = 9,80665 m s⁻²。","note_cs":"Zrychlení je možno uvádět i v jednotkách g (tíhové zrychlení), citlivost snímačů pC/g nebo mV/g, pro 1g = 9,80665 ms⁻².","search_text":"Przyspieszenie prostoliniowych drgań mechanicznych o przebiegu harmonicznym / wzorce drgań i systemy do badań wibracyjnych, wibrometry z przetwornikiem Wzorcowanie – ruch mechaniczny Porównanie z przetwornikiem wzorcowym 7 Hz do 10 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 2,0 % 10 Hz do 100 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,4 % 100 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,0 % 100 Hz do 920 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,2 % 920 Hz do 5 kHz od 0,10 m s⁻² do 200 m s⁻² CMC 1,6 % 5 kHz do 10 kHz od 0,10 m s⁻² do 200 m s⁻² CMC 2,0 % Zrychlení přímočarých mechanických vibrací harmonického průběhu / etalony vibrací a vibrační testovací systémy, vibrometry se snímačem Kalibrace – mechanický pohyb Porovnání s etalonovým snímačem 7 Hz až 10 Hz 0,10 m s⁻² až 200 m s⁻² CMC 2,0 % 10 Hz až 100 Hz 0,10 m s⁻² až 200 m s⁻² CMC 1,4 % 100 Hz 0,10 m s⁻² až 200 m s⁻² CMC 1,0 % 100 Hz až 920 Hz 0,10 m s⁻² až 200 m s⁻² CMC 1,2 % 920 Hz až 5 kHz 0,10 m s⁻² až 200 m s⁻² CMC 1,6 % 5 kHz až 10 kHz 0,10 m s⁻² až 200 m s⁻² CMC 2,0 % KP 2.22 (ČSN ISO 16063-21) Przyspieszenie prostoliniowych drgan mechanicznych o przebiegu harmonicznym / wzorce drgan i systemy do badan wibracyjnych, wibrometry z przetwornikiem Wzorcowanie – ruch mechaniczny Porownanie z przetwornikiem wzorcowym 7 Hz do 10 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 2,0 % 10 Hz do 100 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,4 % 100 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,0 % 100 Hz do 920 Hz od 0,10 m s⁻² do 200 m s⁻² CMC 1,2 % 920 Hz do 5 kHz od 0,10 m s⁻² do 200 m s⁻² CMC 1,6 % 5 kHz do 10 kHz od 0,10 m s⁻² do 200 m s⁻² CMC 2,0 % Zrychleni primocarych mechanickych vibraci harmonickeho prubehu / etalony vibraci a vibracni testovaci systemy, vibrometry se snimacem Kalibrace – mechanicky pohyb Porovnani s etalonovym snimacem 7 Hz az 10 Hz 0,10 m s⁻² az 200 m s⁻² CMC 2,0 % 10 Hz az 100 Hz 0,10 m s⁻² az 200 m s⁻² CMC 1,4 % 100 Hz 0,10 m s⁻² az 200 m s⁻² CMC 1,0 % 100 Hz az 920 Hz 0,10 m s⁻² az 200 m s⁻² CMC 1,2 % 920 Hz az 5 kHz 0,10 m s⁻² az 200 m s⁻² CMC 1,6 % 5 kHz az 10 kHz 0,10 m s⁻² az 200 m s⁻² CMC 2,0 % KP 2.22 (CSN ISO 16063-21)","search_en":"Acceleration of rectilinear mechanical vibrations of harmonic waveform / vibration standards and vibration test systems, vibrometers with a sensor Calibration – mechanical motion Comparison with a reference sensor 7 Hz to 10 Hz 0,10 m s⁻² to 200 m s⁻² CMC 2,0 % 10 Hz to 100 Hz 0,10 m s⁻² to 200 m s⁻² CMC 1,4 % 100 Hz 0,10 m s⁻² to 200 m s⁻² CMC 1,0 % 100 Hz to 920 Hz 0,10 m s⁻² to 200 m s⁻² CMC 1,2 % 920 Hz to 5 kHz 0,10 m s⁻² to 200 m s⁻² CMC 1,6 % 5 kHz to 10 kHz 0,10 m s⁻² to 200 m s⁻² CMC 2,0 % KP 2.22 (ČSN ISO 16063-21)","search_zh":"简谐直线机械振动加速度 / 振动标准器和振动试验系统、带传感器的测振仪 校准 – 机械运动 与标准传感器比较 7 Hz 至 10 Hz 0,10 m s⁻² 至 200 m s⁻² CMC 2,0 % 10 Hz 至 100 Hz 0,10 m s⁻² 至 200 m s⁻² CMC 1,4 % 100 Hz 0,10 m s⁻² 至 200 m s⁻² CMC 1,0 % 100 Hz 至 920 Hz 0,10 m s⁻² 至 200 m s⁻² CMC 1,2 % 920 Hz 至 5 kHz 0,10 m s⁻² 至 200 m s⁻² CMC 1,6 % 5 kHz 至 10 kHz 0,10 m s⁻² 至 200 m s⁻² CMC 2,0 % KP 2.22 (ČSN ISO 16063-21)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ee07e15cdbc44baed67cb37","lab_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","row_label":"1","test_object":"Czułość przetworników / przetworniki drgań","test_object_en":"Sensitivity of sensors / vibration sensors","test_object_zh":"传感器灵敏度 / 振动传感器","test_object_cs":"Citlivost snímačů / snímače vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"7 Hz do 10 Hz","range":"od 0,10 mV/m s⁻² do 3000 mV/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz do 100 Hz","range":"od 0,10 mV/m s⁻² do 3000 mV/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"od 0,10 mV/m s⁻² do 3000 mV/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz do 920 Hz","range":"od 0,10 mV/m s⁻² do 3000 mV/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz do 5 kHz","range":"od 0,10 mV/m s⁻² do 3000 mV/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz do 10 kHz","range":"od 0,10 mV/m s⁻² do 3000 mV/m s⁻²","cmc":"2,2 %"},{"name":"7 Hz do 10 Hz","range":"od 0,10 pC/m s⁻² do 100 pC/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz do 100 Hz","range":"od 0,10 pC/m s⁻² do 100 pC/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"od 0,10 pC/m s⁻² do 100 pC/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz do 920 Hz","range":"od 0,10 pC/m s⁻² do 100 pC/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz do 5 kHz","range":"od 0,10 pC/m s⁻² do 100 pC/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz do 10 kHz","range":"od 0,10 pC/m s⁻² do 100 pC/m s⁻²","cmc":"2,2 %"}],"parameters_en":[{"name":"7 Hz to 10 Hz","range":"0,10 mV/m s⁻² to 3000 mV/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz to 100 Hz","range":"0,10 mV/m s⁻² to 3000 mV/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 mV/m s⁻² to 3000 mV/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz to 920 Hz","range":"0,10 mV/m s⁻² to 3000 mV/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz to 5 kHz","range":"0,10 mV/m s⁻² to 3000 mV/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz to 10 kHz","range":"0,10 mV/m s⁻² to 3000 mV/m s⁻²","cmc":"2,2 %"},{"name":"7 Hz to 10 Hz","range":"0,10 pC/m s⁻² to 100 pC/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz to 100 Hz","range":"0,10 pC/m s⁻² to 100 pC/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 pC/m s⁻² to 100 pC/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz to 920 Hz","range":"0,10 pC/m s⁻² to 100 pC/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz to 5 kHz","range":"0,10 pC/m s⁻² to 100 pC/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz to 10 kHz","range":"0,10 pC/m s⁻² to 100 pC/m s⁻²","cmc":"2,2 %"}],"parameters_zh":[{"name":"7 Hz 至 10 Hz","range":"0,10 mV/m s⁻² 至 3000 mV/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz 至 100 Hz","range":"0,10 mV/m s⁻² 至 3000 mV/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 mV/m s⁻² 至 3000 mV/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz 至 920 Hz","range":"0,10 mV/m s⁻² 至 3000 mV/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz 至 5 kHz","range":"0,10 mV/m s⁻² 至 3000 mV/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz 至 10 kHz","range":"0,10 mV/m s⁻² 至 3000 mV/m s⁻²","cmc":"2,2 %"},{"name":"7 Hz 至 10 Hz","range":"0,10 pC/m s⁻² 至 100 pC/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz 至 100 Hz","range":"0,10 pC/m s⁻² 至 100 pC/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 pC/m s⁻² 至 100 pC/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz 至 920 Hz","range":"0,10 pC/m s⁻² 至 100 pC/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz 至 5 kHz","range":"0,10 pC/m s⁻² 至 100 pC/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz 至 10 kHz","range":"0,10 pC/m s⁻² 至 100 pC/m s⁻²","cmc":"2,2 %"}],"parameters_cs":[{"name":"7 Hz až 10 Hz","range":"0,10 mV/m s⁻² až 3000 mV/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz až 100 Hz","range":"0,10 mV/m s⁻² až 3000 mV/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 mV/m s⁻² až 3000 mV/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz až 920 Hz","range":"0,10 mV/m s⁻² až 3000 mV/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz až 5 kHz","range":"0,10 mV/m s⁻² až 3000 mV/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz až 10 kHz","range":"0,10 mV/m s⁻² až 3000 mV/m s⁻²","cmc":"2,2 %"},{"name":"7 Hz až 10 Hz","range":"0,10 pC/m s⁻² až 100 pC/m s⁻²","cmc":"2,0 %"},{"name":"10 Hz až 100 Hz","range":"0,10 pC/m s⁻² až 100 pC/m s⁻²","cmc":"1,4 %"},{"name":"100 Hz","range":"0,10 pC/m s⁻² až 100 pC/m s⁻²","cmc":"1,0 %"},{"name":"100 Hz až 920 Hz","range":"0,10 pC/m s⁻² až 100 pC/m s⁻²","cmc":"1,2 %"},{"name":"920 Hz až 5 kHz","range":"0,10 pC/m s⁻² až 100 pC/m s⁻²","cmc":"1,6 %"},{"name":"5 kHz až 10 kHz","range":"0,10 pC/m s⁻² až 100 pC/m s⁻²","cmc":"2,2 %"}],"technique":"Porównanie z przetwornikiem wzorcowym","technique_en":"Comparison with a reference sensor","technique_zh":"与标准传感器比较","technique_cs":"Porovnání s etalonovým snímačem","techniques":["Porównanie z przetwornikiem wzorcowym"],"techniques_en":["Comparison with a reference sensor"],"techniques_zh":["与标准传感器比较"],"techniques_cs":["Porovnání s etalonovým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\n7 Hz do 10 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 2,0 %\n10 Hz do 100 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,4 %\n100 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,0 %\n100 Hz do 920 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,2 %\n920 Hz do 5 kHz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,6 %\n5 kHz do 10 kHz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 2,2 %\n7 Hz do 10 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 2,0 %\n10 Hz do 100 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,4 %\n100 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,0 %\n100 Hz do 920 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,2 %\n920 Hz do 5 kHz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,6 %\n5 kHz do 10 kHz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 2,2 %\nPorównanie z przetwornikiem wzorcowym","reference":"KP 2.22 (ČSN ISO 16063-21)","norm_bases":["KP 2.22","ČSN ISO 16063-21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":true,"note":"Przyspieszenie można podawać także w jednostkach g (przyspieszenie ziemskie), czułość przetworników w pC/g lub mV/g, przy 1 g = 9,80665 m s⁻².","note_en":"Acceleration can also be specified in g units (gravitational acceleration), sensitivity of the sensors in pC/g or mV/g, for 1 g = 9,80665 m s⁻².","note_zh":"加速度也可用 g（重力加速度）单位表示，传感器灵敏度可用 pC/g 或 mV/g 表示，1 g = 9,80665 m s⁻²。","note_cs":"Zrychlení je možno uvádět i v jednotkách g (tíhové zrychlení), citlivost snímačů pC/g nebo mV/g, pro 1g = 9,80665 ms⁻².","search_text":"Czułość przetworników / przetworniki drgań Wzorcowanie – ruch mechaniczny Porównanie z przetwornikiem wzorcowym 7 Hz do 10 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 2,0 % 10 Hz do 100 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,4 % 100 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,0 % 100 Hz do 920 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,2 % 920 Hz do 5 kHz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,6 % 5 kHz do 10 kHz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 2,2 % 7 Hz do 10 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 2,0 % 10 Hz do 100 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,4 % 100 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,0 % 100 Hz do 920 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,2 % 920 Hz do 5 kHz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,6 % 5 kHz do 10 kHz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 2,2 % Citlivost snímačů / snímače vibrací Kalibrace – mechanický pohyb Porovnání s etalonovým snímačem 7 Hz až 10 Hz 0,10 mV/m s⁻² až 3000 mV/m s⁻² CMC 2,0 % 10 Hz až 100 Hz 0,10 mV/m s⁻² až 3000 mV/m s⁻² CMC 1,4 % 100 Hz 0,10 mV/m s⁻² až 3000 mV/m s⁻² CMC 1,0 % 100 Hz až 920 Hz 0,10 mV/m s⁻² až 3000 mV/m s⁻² CMC 1,2 % 920 Hz až 5 kHz 0,10 mV/m s⁻² až 3000 mV/m s⁻² CMC 1,6 % 5 kHz až 10 kHz 0,10 mV/m s⁻² až 3000 mV/m s⁻² CMC 2,2 % 7 Hz až 10 Hz 0,10 pC/m s⁻² až 100 pC/m s⁻² CMC 2,0 % 10 Hz až 100 Hz 0,10 pC/m s⁻² až 100 pC/m s⁻² CMC 1,4 % 100 Hz 0,10 pC/m s⁻² až 100 pC/m s⁻² CMC 1,0 % 100 Hz až 920 Hz 0,10 pC/m s⁻² až 100 pC/m s⁻² CMC 1,2 % 920 Hz až 5 kHz 0,10 pC/m s⁻² až 100 pC/m s⁻² CMC 1,6 % 5 kHz až 10 kHz 0,10 pC/m s⁻² až 100 pC/m s⁻² CMC 2,2 % KP 2.22 (ČSN ISO 16063-21) Czulosc przetwornikow / przetworniki drgan Wzorcowanie – ruch mechaniczny Porownanie z przetwornikiem wzorcowym 7 Hz do 10 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 2,0 % 10 Hz do 100 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,4 % 100 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,0 % 100 Hz do 920 Hz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,2 % 920 Hz do 5 kHz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 1,6 % 5 kHz do 10 kHz od 0,10 mV/m s⁻² do 3000 mV/m s⁻² CMC 2,2 % 7 Hz do 10 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 2,0 % 10 Hz do 100 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,4 % 100 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,0 % 100 Hz do 920 Hz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,2 % 920 Hz do 5 kHz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 1,6 % 5 kHz do 10 kHz od 0,10 pC/m s⁻² do 100 pC/m s⁻² CMC 2,2 % Citlivost snimacu / snimace vibraci Kalibrace – mechanicky pohyb Porovnani s etalonovym snimacem 7 Hz az 10 Hz 0,10 mV/m s⁻² az 3000 mV/m s⁻² CMC 2,0 % 10 Hz az 100 Hz 0,10 mV/m s⁻² az 3000 mV/m s⁻² CMC 1,4 % 100 Hz 0,10 mV/m s⁻² az 3000 mV/m s⁻² CMC 1,0 % 100 Hz az 920 Hz 0,10 mV/m s⁻² az 3000 mV/m s⁻² CMC 1,2 % 920 Hz az 5 kHz 0,10 mV/m s⁻² az 3000 mV/m s⁻² CMC 1,6 % 5 kHz az 10 kHz 0,10 mV/m s⁻² az 3000 mV/m s⁻² CMC 2,2 % 7 Hz az 10 Hz 0,10 pC/m s⁻² az 100 pC/m s⁻² CMC 2,0 % 10 Hz az 100 Hz 0,10 pC/m s⁻² az 100 pC/m s⁻² CMC 1,4 % 100 Hz 0,10 pC/m s⁻² az 100 pC/m s⁻² CMC 1,0 % 100 Hz az 920 Hz 0,10 pC/m s⁻² az 100 pC/m s⁻² CMC 1,2 % 920 Hz az 5 kHz 0,10 pC/m s⁻² az 100 pC/m s⁻² CMC 1,6 % 5 kHz az 10 kHz 0,10 pC/m s⁻² az 100 pC/m s⁻² CMC 2,2 % KP 2.22 (CSN ISO 16063-21)","search_en":"Sensitivity of sensors / vibration sensors Calibration – mechanical motion Comparison with a reference sensor 7 Hz to 10 Hz 0,10 mV/m s⁻² to 3000 mV/m s⁻² CMC 2,0 % 10 Hz to 100 Hz 0,10 mV/m s⁻² to 3000 mV/m s⁻² CMC 1,4 % 100 Hz 0,10 mV/m s⁻² to 3000 mV/m s⁻² CMC 1,0 % 100 Hz to 920 Hz 0,10 mV/m s⁻² to 3000 mV/m s⁻² CMC 1,2 % 920 Hz to 5 kHz 0,10 mV/m s⁻² to 3000 mV/m s⁻² CMC 1,6 % 5 kHz to 10 kHz 0,10 mV/m s⁻² to 3000 mV/m s⁻² CMC 2,2 % 7 Hz to 10 Hz 0,10 pC/m s⁻² to 100 pC/m s⁻² CMC 2,0 % 10 Hz to 100 Hz 0,10 pC/m s⁻² to 100 pC/m s⁻² CMC 1,4 % 100 Hz 0,10 pC/m s⁻² to 100 pC/m s⁻² CMC 1,0 % 100 Hz to 920 Hz 0,10 pC/m s⁻² to 100 pC/m s⁻² CMC 1,2 % 920 Hz to 5 kHz 0,10 pC/m s⁻² to 100 pC/m s⁻² CMC 1,6 % 5 kHz to 10 kHz 0,10 pC/m s⁻² to 100 pC/m s⁻² CMC 2,2 % KP 2.22 (ČSN ISO 16063-21)","search_zh":"传感器灵敏度 / 振动传感器 校准 – 机械运动 与标准传感器比较 7 Hz 至 10 Hz 0,10 mV/m s⁻² 至 3000 mV/m s⁻² CMC 2,0 % 10 Hz 至 100 Hz 0,10 mV/m s⁻² 至 3000 mV/m s⁻² CMC 1,4 % 100 Hz 0,10 mV/m s⁻² 至 3000 mV/m s⁻² CMC 1,0 % 100 Hz 至 920 Hz 0,10 mV/m s⁻² 至 3000 mV/m s⁻² CMC 1,2 % 920 Hz 至 5 kHz 0,10 mV/m s⁻² 至 3000 mV/m s⁻² CMC 1,6 % 5 kHz 至 10 kHz 0,10 mV/m s⁻² 至 3000 mV/m s⁻² CMC 2,2 % 7 Hz 至 10 Hz 0,10 pC/m s⁻² 至 100 pC/m s⁻² CMC 2,0 % 10 Hz 至 100 Hz 0,10 pC/m s⁻² 至 100 pC/m s⁻² CMC 1,4 % 100 Hz 0,10 pC/m s⁻² 至 100 pC/m s⁻² CMC 1,0 % 100 Hz 至 920 Hz 0,10 pC/m s⁻² 至 100 pC/m s⁻² CMC 1,2 % 920 Hz 至 5 kHz 0,10 pC/m s⁻² 至 100 pC/m s⁻² CMC 1,6 % 5 kHz 至 10 kHz 0,10 pC/m s⁻² 至 100 pC/m s⁻² CMC 2,2 % KP 2.22 (ČSN ISO 16063-21)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3caabe70a3da22277dcca2d1","lab_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru temperatury komór i szaf termicznych i klimatycznych, pomiar temperatury w urządzeniach z regulacją temperatury i wilgotności","test_object_en":"Thermometers of thermal and climatic chambers and enclosures, measurement of temperature in equipment with temperature and humidity control","test_object_zh":"热箱、气候箱和柜的温度测量器具，温湿度控制设备中的温度测量","test_object_cs":"Měřidla teploty teplotních a klimatických komor a skříní, měření teploty v zařízeních s regulací teploty a vlhkosti","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od - 70 °C do 0 °C","cmc":"0,5 °C"},{"name":"","range":"od 0 °C do 100 °C","cmc":"0,4 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"0,5 °C"},{"name":"","range":"od 200 °C do 250 °C","cmc":"1,0 °C"},{"name":"","range":"od 250 °C do 350 °C","cmc":"1,4 °C"}],"parameters_en":[{"name":"","range":"- 70 °C to 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C to 100 °C","cmc":"0,4 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C to 350 °C","cmc":"1,4 °C"}],"parameters_zh":[{"name":"","range":"- 70 °C 至 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C 至 100 °C","cmc":"0,4 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C 至 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C 至 350 °C","cmc":"1,4 °C"}],"parameters_cs":[{"name":"","range":"- 70 °C až 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C až 100 °C","cmc":"0,4 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C až 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C až 350 °C","cmc":"1,4 °C"}],"technique":"Porównanie z cyfrowym termometrem wzorcowym","technique_en":"Comparison with a reference digital thermometer","technique_zh":"与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem","techniques":["Porównanie z cyfrowym termometrem wzorcowym"],"techniques_en":["Comparison with a reference digital thermometer"],"techniques_zh":["与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod - 70 °C do 0 °C CMC 0,5 °C\nod 0 °C do 100 °C CMC 0,4 °C\nod 100 °C do 200 °C CMC 0,5 °C\nod 200 °C do 250 °C CMC 1,0 °C\nod 250 °C do 350 °C CMC 1,4 °C\nPorównanie z cyfrowym termometrem wzorcowym","reference":"KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","norm_bases":["KP 1.09","DKD - R 5 - 7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru temperatury komór i szaf termicznych i klimatycznych, pomiar temperatury w urządzeniach z regulacją temperatury i wilgotności Wzorcowanie – temperatura Porównanie z cyfrowym termometrem wzorcowym od - 70 °C do 0 °C CMC 0,5 °C od 0 °C do 100 °C CMC 0,4 °C od 100 °C do 200 °C CMC 0,5 °C od 200 °C do 250 °C CMC 1,0 °C od 250 °C do 350 °C CMC 1,4 °C Měřidla teploty teplotních a klimatických komor a skříní, měření teploty v zařízeních s regulací teploty a vlhkosti Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem - 70 °C až 0 °C CMC 0,5 °C 0 °C až 100 °C CMC 0,4 °C 100 °C až 200 °C CMC 0,5 °C 200 °C až 250 °C CMC 1,0 °C 250 °C až 350 °C CMC 1,4 °C KP 1.09 (DKD - R 5 - 7, metoda A, B, C) Przyrzady do pomiaru temperatury komor i szaf termicznych i klimatycznych, pomiar temperatury w urzadzeniach z regulacja temperatury i wilgotnosci Wzorcowanie – temperatura Porownanie z cyfrowym termometrem wzorcowym od - 70 °C do 0 °C CMC 0,5 °C od 0 °C do 100 °C CMC 0,4 °C od 100 °C do 200 °C CMC 0,5 °C od 200 °C do 250 °C CMC 1,0 °C od 250 °C do 350 °C CMC 1,4 °C Meridla teploty teplotnich a klimatickych komor a skrini, mereni teploty v zarizenich s regulaci teploty a vlhkosti Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem - 70 °C az 0 °C CMC 0,5 °C 0 °C az 100 °C CMC 0,4 °C 100 °C az 200 °C CMC 0,5 °C 200 °C az 250 °C CMC 1,0 °C 250 °C az 350 °C CMC 1,4 °C KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","search_en":"Thermometers of thermal and climatic chambers and enclosures, measurement of temperature in equipment with temperature and humidity control Calibration – temperature Comparison with a reference digital thermometer - 70 °C to 0 °C CMC 0,5 °C 0 °C to 100 °C CMC 0,4 °C 100 °C to 200 °C CMC 0,5 °C 200 °C to 250 °C CMC 1,0 °C 250 °C to 350 °C CMC 1,4 °C KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","search_zh":"热箱、气候箱和柜的温度测量器具，温湿度控制设备中的温度测量 校准 – 温度 与标准数字温度计比较 - 70 °C 至 0 °C CMC 0,5 °C 0 °C 至 100 °C CMC 0,4 °C 100 °C 至 200 °C CMC 0,5 °C 200 °C 至 250 °C CMC 1,0 °C 250 °C 至 350 °C CMC 1,4 °C KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5879b3b2edf41e3769b73d83","lab_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / analizatory sygnałów, wibrometry, sterowniki systemów do badań wibracyjnych","test_object_en":"DC voltage / signal analysers, vibrometers, controllers of vibration test systems","test_object_zh":"直流电压 / 信号分析仪、测振仪、振动试验系统控制器","test_object_cs":"Stejnosměrné napětí / Signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,0025 % + 0,00017 mV"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,00090 % + 0,0006 mV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,00070 % + 0,006 mV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,0025 % + 0,00017 mV"},{"name":"","range":"100 mV to 1 V","cmc":"0,00090 % + 0,0006 mV"},{"name":"","range":"1 V to 10 V","cmc":"0,00070 % + 0,006 mV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,0025 % + 0,00017 mV"},{"name":"","range":"100 mV 至 1 V","cmc":"0,00090 % + 0,0006 mV"},{"name":"","range":"1 V 至 10 V","cmc":"0,00070 % + 0,006 mV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,0025 % + 0,00017 mV"},{"name":"","range":"100 mV až 1 V","cmc":"0,00090 % + 0,0006 mV"},{"name":"","range":"1 V až 10 V","cmc":"0,00070 % + 0,006 mV"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准多用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准多用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,0025 % + 0,00017 mV\nod 100 mV do 1 V CMC 0,00090 % + 0,0006 mV\nod 1 V do 10 V CMC 0,00070 % + 0,006 mV\nPorównanie z multimetrem wzorcowym","reference":"KP 3.23","norm_bases":["KP 3.23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / analizatory sygnałów, wibrometry, sterowniki systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0025 % + 0,00017 mV od 100 mV do 1 V CMC 0,00090 % + 0,0006 mV od 1 V do 10 V CMC 0,00070 % + 0,006 mV Stejnosměrné napětí / Signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 0 mV až 100 mV CMC 0,0025 % + 0,00017 mV 100 mV až 1 V CMC 0,00090 % + 0,0006 mV 1 V až 10 V CMC 0,00070 % + 0,006 mV KP 3.23 Napiecie stale / analizatory sygnalow, wibrometry, sterowniki systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym od 0 mV do 100 mV CMC 0,0025 % + 0,00017 mV od 100 mV do 1 V CMC 0,00090 % + 0,0006 mV od 1 V do 10 V CMC 0,00070 % + 0,006 mV Stejnosmerne napeti / Signalove analyzatory, vibrometry, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 0 mV az 100 mV CMC 0,0025 % + 0,00017 mV 100 mV az 1 V CMC 0,00090 % + 0,0006 mV 1 V az 10 V CMC 0,00070 % + 0,006 mV KP 3.23","search_en":"DC voltage / signal analysers, vibrometers, controllers of vibration test systems Calibration – electrical quantities Comparison with a reference multimeter 0 mV to 100 mV CMC 0,0025 % + 0,00017 mV 100 mV to 1 V CMC 0,00090 % + 0,0006 mV 1 V to 10 V CMC 0,00070 % + 0,006 mV KP 3.23","search_zh":"直流电压 / 信号分析仪、测振仪、振动试验系统控制器 校准 – 电学量 与标准多用表比较 0 mV 至 100 mV CMC 0,0025 % + 0,00017 mV 100 mV 至 1 V CMC 0,00090 % + 0,0006 mV 1 V 至 10 V CMC 0,00070 % + 0,006 mV KP 3.23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"510802dc96e74c5a6087a41b","lab_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne – wartość szczytowa / analizatory sygnałów, wibrometry, sterowniki systemów do badań wibracyjnych","test_object_en":"AC voltage – peak value / signal analysers, vibrometers, controllers of vibration test systems","test_object_zh":"交流电压 – 峰值 / 信号分析仪、测振仪、振动试验系统控制器","test_object_cs":"Střídavé napětí – špičková hodnota / Signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 1 mV do 100 mV","cmc":"0,08 % + 0,015 mV"},{"name":"40 Hz do 200 Hz","range":"od 1 mV do 100 mV","cmc":"0,03 % + 0,009 mV"},{"name":"200 Hz do 2000 Hz","range":"od 1 mV do 100 mV","cmc":"0,03 % + 0,008 mV"},{"name":"2 kHz do 20 kHz","range":"od 1 mV do 100 mV","cmc":"0,04 % + 0,010 mV"},{"name":"10 Hz do 40 Hz","range":"od 100 mV do 1 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz do 200 Hz","range":"od 100 mV do 1 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz do 2000 Hz","range":"od 100 mV do 1 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz do 20 kHz","range":"od 100 mV do 1 V","cmc":"0,04 % + 0,10 mV"},{"name":"10 Hz do 40 Hz","range":"od 1 V do 10 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz do 200 Hz","range":"od 1 V do 10 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz do 2000 Hz","range":"od 1 V do 10 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz do 20 kHz","range":"od 1 V do 10 V","cmc":"0,04 % + 0,10 mV"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"1 mV to 100 mV","cmc":"0,08 % + 0,015 mV"},{"name":"40 Hz to 200 Hz","range":"1 mV to 100 mV","cmc":"0,03 % + 0,009 mV"},{"name":"200 Hz to 2000 Hz","range":"1 mV to 100 mV","cmc":"0,03 % + 0,008 mV"},{"name":"2 kHz to 20 kHz","range":"1 mV to 100 mV","cmc":"0,04 % + 0,010 mV"},{"name":"10 Hz to 40 Hz","range":"100 mV to 1 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz to 200 Hz","range":"100 mV to 1 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz to 2000 Hz","range":"100 mV to 1 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz to 20 kHz","range":"100 mV to 1 V","cmc":"0,04 % + 0,10 mV"},{"name":"10 Hz to 40 Hz","range":"1 V to 10 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz to 200 Hz","range":"1 V to 10 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz to 2000 Hz","range":"1 V to 10 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz to 20 kHz","range":"1 V to 10 V","cmc":"0,04 % + 0,10 mV"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"1 mV 至 100 mV","cmc":"0,08 % + 0,015 mV"},{"name":"40 Hz 至 200 Hz","range":"1 mV 至 100 mV","cmc":"0,03 % + 0,009 mV"},{"name":"200 Hz 至 2000 Hz","range":"1 mV 至 100 mV","cmc":"0,03 % + 0,008 mV"},{"name":"2 kHz 至 20 kHz","range":"1 mV 至 100 mV","cmc":"0,04 % + 0,010 mV"},{"name":"10 Hz 至 40 Hz","range":"100 mV 至 1 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz 至 200 Hz","range":"100 mV 至 1 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz 至 2000 Hz","range":"100 mV 至 1 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz 至 20 kHz","range":"100 mV 至 1 V","cmc":"0,04 % + 0,10 mV"},{"name":"10 Hz 至 40 Hz","range":"1 V 至 10 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz 至 200 Hz","range":"1 V 至 10 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz 至 2000 Hz","range":"1 V 至 10 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz 至 20 kHz","range":"1 V 至 10 V","cmc":"0,04 % + 0,10 mV"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"1 mV až 100 mV","cmc":"0,08 % + 0,015 mV"},{"name":"40 Hz až 200 Hz","range":"1 mV až 100 mV","cmc":"0,03 % + 0,009 mV"},{"name":"200 Hz až 2000 Hz","range":"1 mV až 100 mV","cmc":"0,03 % + 0,008 mV"},{"name":"2 kHz až 20 kHz","range":"1 mV až 100 mV","cmc":"0,04 % + 0,010 mV"},{"name":"10 Hz až 40 Hz","range":"100 mV až 1 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz až 200 Hz","range":"100 mV až 1 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz až 2000 Hz","range":"100 mV až 1 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz až 20 kHz","range":"100 mV až 1 V","cmc":"0,04 % + 0,10 mV"},{"name":"10 Hz až 40 Hz","range":"1 V až 10 V","cmc":"0,06 % + 0,10 mV"},{"name":"40 Hz až 200 Hz","range":"1 V až 10 V","cmc":"0,03 % + 0,15 mV"},{"name":"200 Hz až 2000 Hz","range":"1 V až 10 V","cmc":"0,02 % + 0,06 mV"},{"name":"2 kHz až 20 kHz","range":"1 V až 10 V","cmc":"0,04 % + 0,10 mV"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准多用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准多用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 1 mV do 100 mV CMC 0,08 % + 0,015 mV\n40 Hz do 200 Hz od 1 mV do 100 mV CMC 0,03 % + 0,009 mV\n200 Hz do 2000 Hz od 1 mV do 100 mV CMC 0,03 % + 0,008 mV\n2 kHz do 20 kHz od 1 mV do 100 mV CMC 0,04 % + 0,010 mV\n10 Hz do 40 Hz od 100 mV do 1 V CMC 0,06 % + 0,10 mV\n40 Hz do 200 Hz od 100 mV do 1 V CMC 0,03 % + 0,15 mV\n200 Hz do 2000 Hz od 100 mV do 1 V CMC 0,02 % + 0,06 mV\n2 kHz do 20 kHz od 100 mV do 1 V CMC 0,04 % + 0,10 mV\n10 Hz do 40 Hz od 1 V do 10 V CMC 0,06 % + 0,10 mV\n40 Hz do 200 Hz od 1 V do 10 V CMC 0,03 % + 0,15 mV\n200 Hz do 2000 Hz od 1 V do 10 V CMC 0,02 % + 0,06 mV\n2 kHz do 20 kHz od 1 V do 10 V CMC 0,04 % + 0,10 mV\nPorównanie z multimetrem wzorcowym","reference":"KP 3.23","norm_bases":["KP 3.23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne – wartość szczytowa / analizatory sygnałów, wibrometry, sterowniki systemów do badań wibracyjnych Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 10 Hz do 40 Hz od 1 mV do 100 mV CMC 0,08 % + 0,015 mV 40 Hz do 200 Hz od 1 mV do 100 mV CMC 0,03 % + 0,009 mV 200 Hz do 2000 Hz od 1 mV do 100 mV CMC 0,03 % + 0,008 mV 2 kHz do 20 kHz od 1 mV do 100 mV CMC 0,04 % + 0,010 mV 10 Hz do 40 Hz od 100 mV do 1 V CMC 0,06 % + 0,10 mV 40 Hz do 200 Hz od 100 mV do 1 V CMC 0,03 % + 0,15 mV 200 Hz do 2000 Hz od 100 mV do 1 V CMC 0,02 % + 0,06 mV 2 kHz do 20 kHz od 100 mV do 1 V CMC 0,04 % + 0,10 mV 10 Hz do 40 Hz od 1 V do 10 V CMC 0,06 % + 0,10 mV 40 Hz do 200 Hz od 1 V do 10 V CMC 0,03 % + 0,15 mV 200 Hz do 2000 Hz od 1 V do 10 V CMC 0,02 % + 0,06 mV 2 kHz do 20 kHz od 1 V do 10 V CMC 0,04 % + 0,10 mV Střídavé napětí – špičková hodnota / Signálové analyzátory, vibrometry, kontroléry vibračních testovacích systémů Kalibrace – elektrické veličiny Porovnání s etalonovým multimetrem 10 Hz až 40 Hz 1 mV až 100 mV CMC 0,08 % + 0,015 mV 40 Hz až 200 Hz 1 mV až 100 mV CMC 0,03 % + 0,009 mV 200 Hz až 2000 Hz 1 mV až 100 mV CMC 0,03 % + 0,008 mV 2 kHz až 20 kHz 1 mV až 100 mV CMC 0,04 % + 0,010 mV 10 Hz až 40 Hz 100 mV až 1 V CMC 0,06 % + 0,10 mV 40 Hz až 200 Hz 100 mV až 1 V CMC 0,03 % + 0,15 mV 200 Hz až 2000 Hz 100 mV až 1 V CMC 0,02 % + 0,06 mV 2 kHz až 20 kHz 100 mV až 1 V CMC 0,04 % + 0,10 mV 10 Hz až 40 Hz 1 V až 10 V CMC 0,06 % + 0,10 mV 40 Hz až 200 Hz 1 V až 10 V CMC 0,03 % + 0,15 mV 200 Hz až 2000 Hz 1 V až 10 V CMC 0,02 % + 0,06 mV 2 kHz až 20 kHz 1 V až 10 V CMC 0,04 % + 0,10 mV KP 3.23 Napiecie przemienne – wartosc szczytowa / analizatory sygnalow, wibrometry, sterowniki systemow do badan wibracyjnych Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 10 Hz do 40 Hz od 1 mV do 100 mV CMC 0,08 % + 0,015 mV 40 Hz do 200 Hz od 1 mV do 100 mV CMC 0,03 % + 0,009 mV 200 Hz do 2000 Hz od 1 mV do 100 mV CMC 0,03 % + 0,008 mV 2 kHz do 20 kHz od 1 mV do 100 mV CMC 0,04 % + 0,010 mV 10 Hz do 40 Hz od 100 mV do 1 V CMC 0,06 % + 0,10 mV 40 Hz do 200 Hz od 100 mV do 1 V CMC 0,03 % + 0,15 mV 200 Hz do 2000 Hz od 100 mV do 1 V CMC 0,02 % + 0,06 mV 2 kHz do 20 kHz od 100 mV do 1 V CMC 0,04 % + 0,10 mV 10 Hz do 40 Hz od 1 V do 10 V CMC 0,06 % + 0,10 mV 40 Hz do 200 Hz od 1 V do 10 V CMC 0,03 % + 0,15 mV 200 Hz do 2000 Hz od 1 V do 10 V CMC 0,02 % + 0,06 mV 2 kHz do 20 kHz od 1 V do 10 V CMC 0,04 % + 0,10 mV Stridave napeti – spickova hodnota / Signalove analyzatory, vibrometry, kontrolery vibracnich testovacich systemu Kalibrace – elektricke veliciny Porovnani s etalonovym multimetrem 10 Hz az 40 Hz 1 mV az 100 mV CMC 0,08 % + 0,015 mV 40 Hz az 200 Hz 1 mV az 100 mV CMC 0,03 % + 0,009 mV 200 Hz az 2000 Hz 1 mV az 100 mV CMC 0,03 % + 0,008 mV 2 kHz az 20 kHz 1 mV az 100 mV CMC 0,04 % + 0,010 mV 10 Hz az 40 Hz 100 mV az 1 V CMC 0,06 % + 0,10 mV 40 Hz az 200 Hz 100 mV az 1 V CMC 0,03 % + 0,15 mV 200 Hz az 2000 Hz 100 mV az 1 V CMC 0,02 % + 0,06 mV 2 kHz az 20 kHz 100 mV az 1 V CMC 0,04 % + 0,10 mV 10 Hz az 40 Hz 1 V az 10 V CMC 0,06 % + 0,10 mV 40 Hz az 200 Hz 1 V az 10 V CMC 0,03 % + 0,15 mV 200 Hz az 2000 Hz 1 V az 10 V CMC 0,02 % + 0,06 mV 2 kHz az 20 kHz 1 V az 10 V CMC 0,04 % + 0,10 mV KP 3.23","search_en":"AC voltage – peak value / signal analysers, vibrometers, controllers of vibration test systems Calibration – electrical quantities Comparison with a reference multimeter 10 Hz to 40 Hz 1 mV to 100 mV CMC 0,08 % + 0,015 mV 40 Hz to 200 Hz 1 mV to 100 mV CMC 0,03 % + 0,009 mV 200 Hz to 2000 Hz 1 mV to 100 mV CMC 0,03 % + 0,008 mV 2 kHz to 20 kHz 1 mV to 100 mV CMC 0,04 % + 0,010 mV 10 Hz to 40 Hz 100 mV to 1 V CMC 0,06 % + 0,10 mV 40 Hz to 200 Hz 100 mV to 1 V CMC 0,03 % + 0,15 mV 200 Hz to 2000 Hz 100 mV to 1 V CMC 0,02 % + 0,06 mV 2 kHz to 20 kHz 100 mV to 1 V CMC 0,04 % + 0,10 mV 10 Hz to 40 Hz 1 V to 10 V CMC 0,06 % + 0,10 mV 40 Hz to 200 Hz 1 V to 10 V CMC 0,03 % + 0,15 mV 200 Hz to 2000 Hz 1 V to 10 V CMC 0,02 % + 0,06 mV 2 kHz to 20 kHz 1 V to 10 V CMC 0,04 % + 0,10 mV KP 3.23","search_zh":"交流电压 – 峰值 / 信号分析仪、测振仪、振动试验系统控制器 校准 – 电学量 与标准多用表比较 10 Hz 至 40 Hz 1 mV 至 100 mV CMC 0,08 % + 0,015 mV 40 Hz 至 200 Hz 1 mV 至 100 mV CMC 0,03 % + 0,009 mV 200 Hz 至 2000 Hz 1 mV 至 100 mV CMC 0,03 % + 0,008 mV 2 kHz 至 20 kHz 1 mV 至 100 mV CMC 0,04 % + 0,010 mV 10 Hz 至 40 Hz 100 mV 至 1 V CMC 0,06 % + 0,10 mV 40 Hz 至 200 Hz 100 mV 至 1 V CMC 0,03 % + 0,15 mV 200 Hz 至 2000 Hz 100 mV 至 1 V CMC 0,02 % + 0,06 mV 2 kHz 至 20 kHz 100 mV 至 1 V CMC 0,04 % + 0,10 mV 10 Hz 至 40 Hz 1 V 至 10 V CMC 0,06 % + 0,10 mV 40 Hz 至 200 Hz 1 V 至 10 V CMC 0,03 % + 0,15 mV 200 Hz 至 2000 Hz 1 V 至 10 V CMC 0,02 % + 0,06 mV 2 kHz 至 20 kHz 1 V 至 10 V CMC 0,04 % + 0,10 mV KP 3.23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"30635ac494bf004fef1b0b3e","lab_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","row_label":"1","test_object":"Mierniki częstotliwości – analizatory sygnałów, wibrometry, liczniki, sterowniki systemów do badań wibracyjnych","test_object_en":"Frequency meters – signal analysers, vibrometers, counters, controllers of vibration test systems","test_object_zh":"频率测量器具 – 信号分析仪、测振仪、计数器、振动试验系统控制器","test_object_cs":"Měřidla frekvence - signálové, analyzátory, vibrometry, čítače, kontroléry vibračních testovacích systémů","methodology":"Wzorcowanie – częstotliwość","methodology_en":"Calibration – frequency","methodology_zh":"校准 – 频率","methodology_cs":"Kalibrace – frekvence","parameters":[{"name":"100 mV do 10 V","range":"od 1 Hz do 100 Hz","cmc":"0,001 % + 0,020 mHz"},{"name":"100 mV do 10 V","range":"od 100 Hz do 1000 Hz","cmc":"0,001 % + 0,20 mHz"},{"name":"100 mV do 10 V","range":"od 1 kHz do 10 kHz","cmc":"0,001 % + 2,0 mHz"}],"parameters_en":[{"name":"100 mV to 10 V","range":"1 Hz to 100 Hz","cmc":"0,001 % + 0,020 mHz"},{"name":"100 mV to 10 V","range":"100 Hz to 1000 Hz","cmc":"0,001 % + 0,20 mHz"},{"name":"100 mV to 10 V","range":"1 kHz to 10 kHz","cmc":"0,001 % + 2,0 mHz"}],"parameters_zh":[{"name":"100 mV 至 10 V","range":"1 Hz 至 100 Hz","cmc":"0,001 % + 0,020 mHz"},{"name":"100 mV 至 10 V","range":"100 Hz 至 1000 Hz","cmc":"0,001 % + 0,20 mHz"},{"name":"100 mV 至 10 V","range":"1 kHz 至 10 kHz","cmc":"0,001 % + 2,0 mHz"}],"parameters_cs":[{"name":"100 mV až 10 V","range":"1 Hz až 100 Hz","cmc":"0,001 % + 0,020 mHz"},{"name":"100 mV až 10 V","range":"100 Hz až 1000 Hz","cmc":"0,001 % + 0,20 mHz"},{"name":"100 mV až 10 V","range":"1 kHz až 10 kHz","cmc":"0,001 % + 2,0 mHz"}],"technique":"Porównanie z multimetrem wzorcowym","technique_en":"Comparison with a reference multimeter","technique_zh":"与标准多用表比较","technique_cs":"Porovnání s etalonovým multimetrem","techniques":["Porównanie z multimetrem wzorcowym"],"techniques_en":["Comparison with a reference multimeter"],"techniques_zh":["与标准多用表比较"],"techniques_cs":["Porovnání s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – częstotliwość\nZakres:\n100 mV do 10 V od 1 Hz do 100 Hz CMC 0,001 % + 0,020 mHz\n100 mV do 10 V od 100 Hz do 1000 Hz CMC 0,001 % + 0,20 mHz\n100 mV do 10 V od 1 kHz do 10 kHz CMC 0,001 % + 2,0 mHz\nPorównanie z multimetrem wzorcowym","reference":"KP 3.23","norm_bases":["KP 3.23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: częstotliwość","regulatory_area_en":"CMC for the field of measured quantity: Frequency","regulatory_area_zh":"被测量领域的CMC：频率","regulatory_area_cs":"CMC pro obor měřené veličiny: Frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki częstotliwości – analizatory sygnałów, wibrometry, liczniki, sterowniki systemów do badań wibracyjnych Wzorcowanie – częstotliwość Porównanie z multimetrem wzorcowym 100 mV do 10 V od 1 Hz do 100 Hz CMC 0,001 % + 0,020 mHz 100 mV do 10 V od 100 Hz do 1000 Hz CMC 0,001 % + 0,20 mHz 100 mV do 10 V od 1 kHz do 10 kHz CMC 0,001 % + 2,0 mHz Měřidla frekvence - signálové, analyzátory, vibrometry, čítače, kontroléry vibračních testovacích systémů Kalibrace – frekvence Porovnání s etalonovým multimetrem 100 mV až 10 V 1 Hz až 100 Hz CMC 0,001 % + 0,020 mHz 100 mV až 10 V 100 Hz až 1000 Hz CMC 0,001 % + 0,20 mHz 100 mV až 10 V 1 kHz až 10 kHz CMC 0,001 % + 2,0 mHz KP 3.23 Mierniki czestotliwosci – analizatory sygnalow, wibrometry, liczniki, sterowniki systemow do badan wibracyjnych Wzorcowanie – czestotliwosc Porownanie z multimetrem wzorcowym 100 mV do 10 V od 1 Hz do 100 Hz CMC 0,001 % + 0,020 mHz 100 mV do 10 V od 100 Hz do 1000 Hz CMC 0,001 % + 0,20 mHz 100 mV do 10 V od 1 kHz do 10 kHz CMC 0,001 % + 2,0 mHz Meridla frekvence - signalove, analyzatory, vibrometry, citace, kontrolery vibracnich testovacich systemu Kalibrace – frekvence Porovnani s etalonovym multimetrem 100 mV az 10 V 1 Hz az 100 Hz CMC 0,001 % + 0,020 mHz 100 mV az 10 V 100 Hz az 1000 Hz CMC 0,001 % + 0,20 mHz 100 mV az 10 V 1 kHz az 10 kHz CMC 0,001 % + 2,0 mHz KP 3.23","search_en":"Frequency meters – signal analysers, vibrometers, counters, controllers of vibration test systems Calibration – frequency Comparison with a reference multimeter 100 mV to 10 V 1 Hz to 100 Hz CMC 0,001 % + 0,020 mHz 100 mV to 10 V 100 Hz to 1000 Hz CMC 0,001 % + 0,20 mHz 100 mV to 10 V 1 kHz to 10 kHz CMC 0,001 % + 2,0 mHz KP 3.23","search_zh":"频率测量器具 – 信号分析仪、测振仪、计数器、振动试验系统控制器 校准 – 频率 与标准多用表比较 100 mV 至 10 V 1 Hz 至 100 Hz CMC 0,001 % + 0,020 mHz 100 mV 至 10 V 100 Hz 至 1000 Hz CMC 0,001 % + 0,20 mHz 100 mV 至 10 V 1 kHz 至 10 kHz CMC 0,001 % + 2,0 mHz KP 3.23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"47d5af7ea1ac671aee37cfff","lab_id":"6acfffeaff06824761705e17","country":"CZ","accr_number":"2358","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru wilgotności komór i szaf termicznych i klimatycznych, pomiar wilgotności w urządzeniach z regulacją temperatury i wilgotności","test_object_en":"Humidity meters of thermal and climatic chambers and enclosures, measurement of humidity in equipment with temperature and humidity control","test_object_zh":"热箱、气候箱和柜的湿度测量器具，温湿度控制设备中的湿度测量","test_object_cs":"Měřidla vlhkosti teplotních a klimatických komor a skříní, měření vlhkosti v zařízeních s regulací teploty a vlhkosti","methodology":"Wzorcowanie – wilgotność","methodology_en":"Calibration – humidity","methodology_zh":"校准 – 湿度","methodology_cs":"Kalibrace – vlhkost","parameters":[{"name":"(18 do 32) °C","range":"od 10 % RH do 30 % RH","cmc":"1,6 % RH"},{"name":"(18 do 32) °C","range":"od 30 % RH do 60 % RH","cmc":"1,9 % RH"},{"name":"(18 do 32) °C","range":"od 60 % RH do 95 % RH","cmc":"2,2 % RH"}],"parameters_en":[{"name":"(18 to 32) °C","range":"10 % RH to 30 % RH","cmc":"1,6 % RH"},{"name":"(18 to 32) °C","range":"30 % RH to 60 % RH","cmc":"1,9 % RH"},{"name":"(18 to 32) °C","range":"60 % RH to 95 % RH","cmc":"2,2 % RH"}],"parameters_zh":[{"name":"(18 至 32) °C","range":"10 % RH 至 30 % RH","cmc":"1,6 % RH"},{"name":"(18 至 32) °C","range":"30 % RH 至 60 % RH","cmc":"1,9 % RH"},{"name":"(18 至 32) °C","range":"60 % RH 至 95 % RH","cmc":"2,2 % RH"}],"parameters_cs":[{"name":"(18 až 32) °C","range":"10 % RH až 30 % RH","cmc":"1,6 % RH"},{"name":"(18 až 32) °C","range":"30 % RH až 60 % RH","cmc":"1,9 % RH"},{"name":"(18 až 32) °C","range":"60 % RH až 95 % RH","cmc":"2,2 % RH"}],"technique":"Porównanie z cyfrowym wilgotnościomierzem wzorcowym","technique_en":"Comparison with a reference digital hygrometer","technique_zh":"与标准数字湿度计比较","technique_cs":"Porovnání s etalonovým digitálním vlhkoměrem","techniques":["Porównanie z cyfrowym wilgotnościomierzem wzorcowym"],"techniques_en":["Comparison with a reference digital hygrometer"],"techniques_zh":["与标准数字湿度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność\nZakres:\n(18 do 32) °C od 10 % RH do 30 % RH CMC 1,6 % RH\n(18 do 32) °C od 30 % RH do 60 % RH CMC 1,9 % RH\n(18 do 32) °C od 60 % RH do 95 % RH CMC 2,2 % RH\nPorównanie z cyfrowym wilgotnościomierzem wzorcowym","reference":"KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","norm_bases":["KP 1.09","DKD - R 5 - 7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Humidity","regulatory_area_zh":"被测量领域的CMC：湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru wilgotności komór i szaf termicznych i klimatycznych, pomiar wilgotności w urządzeniach z regulacją temperatury i wilgotności Wzorcowanie – wilgotność Porównanie z cyfrowym wilgotnościomierzem wzorcowym (18 do 32) °C od 10 % RH do 30 % RH CMC 1,6 % RH (18 do 32) °C od 30 % RH do 60 % RH CMC 1,9 % RH (18 do 32) °C od 60 % RH do 95 % RH CMC 2,2 % RH Měřidla vlhkosti teplotních a klimatických komor a skříní, měření vlhkosti v zařízeních s regulací teploty a vlhkosti Kalibrace – vlhkost Porovnání s etalonovým digitálním vlhkoměrem (18 až 32) °C 10 % RH až 30 % RH CMC 1,6 % RH (18 až 32) °C 30 % RH až 60 % RH CMC 1,9 % RH (18 až 32) °C 60 % RH až 95 % RH CMC 2,2 % RH KP 1.09 (DKD - R 5 - 7, metoda A, B, C) Przyrzady do pomiaru wilgotnosci komor i szaf termicznych i klimatycznych, pomiar wilgotnosci w urzadzeniach z regulacja temperatury i wilgotnosci Wzorcowanie – wilgotnosc Porownanie z cyfrowym wilgotnosciomierzem wzorcowym (18 do 32) °C od 10 % RH do 30 % RH CMC 1,6 % RH (18 do 32) °C od 30 % RH do 60 % RH CMC 1,9 % RH (18 do 32) °C od 60 % RH do 95 % RH CMC 2,2 % RH Meridla vlhkosti teplotnich a klimatickych komor a skrini, mereni vlhkosti v zarizenich s regulaci teploty a vlhkosti Kalibrace – vlhkost Porovnani s etalonovym digitalnim vlhkomerem (18 az 32) °C 10 % RH az 30 % RH CMC 1,6 % RH (18 az 32) °C 30 % RH az 60 % RH CMC 1,9 % RH (18 az 32) °C 60 % RH az 95 % RH CMC 2,2 % RH KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","search_en":"Humidity meters of thermal and climatic chambers and enclosures, measurement of humidity in equipment with temperature and humidity control Calibration – humidity Comparison with a reference digital hygrometer (18 to 32) °C 10 % RH to 30 % RH CMC 1,6 % RH (18 to 32) °C 30 % RH to 60 % RH CMC 1,9 % RH (18 to 32) °C 60 % RH to 95 % RH CMC 2,2 % RH KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","search_zh":"热箱、气候箱和柜的湿度测量器具，温湿度控制设备中的湿度测量 校准 – 湿度 与标准数字湿度计比较 (18 至 32) °C 10 % RH 至 30 % RH CMC 1,6 % RH (18 至 32) °C 30 % RH 至 60 % RH CMC 1,9 % RH (18 至 32) °C 60 % RH 至 95 % RH CMC 2,2 % RH KP 1.09 (DKD - R 5 - 7, metoda A, B, C)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}