{"lab":{"_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","address":"U Hrůbků 170/18, Nová Ves, 709 00 Ostrava","categories":["metrology"],"city":"Ostrava","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[18.2195002,49.8188354]},"map_coord":[49.8188354,18.2195002],"map_geo":"cai-mapa","methods_count":19,"name":"PTS Josef Solnař, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie: badania właściwości i wad materiałów, w zakresie określonym w załączniku do świadectwa.","search_text":"pts josef solnař, s.r.o. u hrůbků 170/18, nová ves, 709 00 ostrava 2355","source_page_url":"https://www.cai.cz/?subjekt=2355-pts-josef-solnar-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"29-11-2027","website":"www.ptsndt.com","certificate_date":"29.09.2026","certificate_no":"445/2026","certificate_replaces":"327/2025 z 30.06.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie: badania właściwości i wad materiałów, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of testing of material properties and defects, to the extent specified in the appendix to this Certificate.","zh":"材料性能和缺陷检测领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru zkoušky vlastností a vad materiálů, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"SW","pl":"szerokość ekranu","en":"screen width","zh":"屏幕宽度","cs":"šířka obrazovky"},{"abbr":"SH","pl":"wysokość ekranu","en":"screen height","zh":"屏幕高度","cs":"výška obrazovky"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"9f8c5f2774bed787ae1ca644878bf3cde527eda3d279be2eac70bfaba7ff5f17","source_pdf_url":"https://www.cai.cz/OA/pdf/445_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"24550eb0262583c3d03bb8fc","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"1","test_object":"Defektoskopy ultradźwiękowe","test_object_en":"Ultrasonic flaw detectors","test_object_zh":"超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Stabilność – pomiar amplitudy","range":"od 0 % SH do 100 % SH","cmc":"1,4 % SH"},{"name":"Stabilność – pomiar położenia","range":"od 0 % SW do 100 % SW","cmc":"1,1 % SW"},{"name":"Odbiornik – fₗₘ, dolna częstotliwość graniczna","range":"od 0,1 MHz do 25 MHz","cmc":"3,3 %"},{"name":"Odbiornik – fᵤₘ, górna częstotliwość graniczna","range":"od 0,1 MHz do 25 MHz","cmc":"3,3 %"},{"name":"Odbiornik – f₀, częstotliwość środkowa","range":"od 0,1 MHz do 25 MHz","cmc":"3,5 %"},{"name":"Odbiornik – Δf, szerokość pasma","range":"od 0,1 MHz do 25 MHz","cmc":"4,7 %"},{"name":"Liniowość podstawy czasu dla przyrządów cyfrowych","range":"od 0,5 µs do 2000 µs","cmc":"1,1 % + 0,05 µs"}],"parameters_en":[{"name":"Stability – amplitude measurement","range":"0 % SH to 100 % SH","cmc":"1,4 % SH"},{"name":"Stability – position measurement","range":"0 % SW to 100 % SW","cmc":"1,1 % SW"},{"name":"Receiver – fₗₘ, lower cut-off frequency","range":"0,1 MHz to 25 MHz","cmc":"3,3 %"},{"name":"Receiver – fᵤₘ, upper cut-off frequency","range":"0,1 MHz to 25 MHz","cmc":"3,3 %"},{"name":"Receiver – f₀, centre frequency","range":"0,1 MHz to 25 MHz","cmc":"3,5 %"},{"name":"Receiver – Δf, bandwidth","range":"0,1 MHz to 25 MHz","cmc":"4,7 %"},{"name":"Time base linearity for digital instruments","range":"0,5 µs to 2000 µs","cmc":"1,1 % + 0,05 µs"}],"parameters_zh":[{"name":"稳定性 – 幅度测量","range":"0 % SH 至 100 % SH","cmc":"1,4 % SH"},{"name":"稳定性 – 位置测量","range":"0 % SW 至 100 % SW","cmc":"1,1 % SW"},{"name":"接收器 – fₗₘ，下限截止频率","range":"0,1 MHz 至 25 MHz","cmc":"3,3 %"},{"name":"接收器 – fᵤₘ，上限截止频率","range":"0,1 MHz 至 25 MHz","cmc":"3,3 %"},{"name":"接收器 – f₀，中心频率","range":"0,1 MHz 至 25 MHz","cmc":"3,5 %"},{"name":"接收器 – Δf，带宽","range":"0,1 MHz 至 25 MHz","cmc":"4,7 %"},{"name":"数字仪器时基线性","range":"0,5 µs 至 2000 µs","cmc":"1,1 % + 0,05 µs"}],"parameters_cs":[{"name":"Stabilita – měření amplitudy","range":"0 % SH až 100 % SH","cmc":"1,4 % SH"},{"name":"Stabilita – měření pozice","range":"0 % SW až 100 % SW","cmc":"1,1 % SW"},{"name":"Přijímač – fₗₘ, dolní mezní frekvence","range":"0,1 MHz až 25 MHz","cmc":"3,3 %"},{"name":"Přijímač – fᵤₘ, horní mezní frekvence","range":"0,1 MHz až 25 MHz","cmc":"3,3 %"},{"name":"Přijímač – f₀, střední frekvence","range":"0,1 MHz až 25 MHz","cmc":"3,5 %"},{"name":"Přijímač – Δf, šířka pásma","range":"0,1 MHz až 25 MHz","cmc":"4,7 %"},{"name":"Linearita časové základny pro digitální přístroje","range":"0,5 µs až 2000 µs","cmc":"1,1 % + 0,05 µs"}],"technique":"Generowanie sygnału wzorcowym generatorem","technique_en":"Signal generation with a standard generator","technique_zh":"用标准信号发生器产生信号","technique_cs":"Generování signálu etalonovým generátorem","techniques":["Generowanie sygnału wzorcowym generatorem"],"techniques_en":["Signal generation with a standard generator"],"techniques_zh":["用标准信号发生器产生信号"],"techniques_cs":["Generování signálu etalonovým generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nStabilność – pomiar amplitudy od 0 % SH do 100 % SH CMC 1,4 % SH\nStabilność – pomiar położenia od 0 % SW do 100 % SW CMC 1,1 % SW\nOdbiornik – fₗₘ, dolna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 %\nOdbiornik – fᵤₘ, górna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 %\nOdbiornik – f₀, częstotliwość środkowa od 0,1 MHz do 25 MHz CMC 3,5 %\nOdbiornik – Δf, szerokość pasma od 0,1 MHz do 25 MHz CMC 4,7 %\nLiniowość podstawy czasu dla przyrządów cyfrowych od 0,5 µs do 2000 µs CMC 1,1 % + 0,05 µs\nGenerowanie sygnału wzorcowym generatorem","reference":"A 04-55/31 (ČSN EN 12668-1:2010)","norm_bases":["A 04-55/31","ČSN EN 12668-1:2010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe Wzorcowanie – badania właściwości i wad materiałów Generowanie sygnału wzorcowym generatorem Stabilność – pomiar amplitudy od 0 % SH do 100 % SH CMC 1,4 % SH Stabilność – pomiar położenia od 0 % SW do 100 % SW CMC 1,1 % SW Odbiornik – fₗₘ, dolna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – fᵤₘ, górna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – f₀, częstotliwość środkowa od 0,1 MHz do 25 MHz CMC 3,5 % Odbiornik – Δf, szerokość pasma od 0,1 MHz do 25 MHz CMC 4,7 % Liniowość podstawy czasu dla przyrządów cyfrowych od 0,5 µs do 2000 µs CMC 1,1 % + 0,05 µs Ultrazvukové defektoskopy Kalibrace – zkoušky vlastností a vad materiálů Generování signálu etalonovým generátorem Stabilita – měření amplitudy 0 % SH až 100 % SH CMC 1,4 % SH Stabilita – měření pozice 0 % SW až 100 % SW CMC 1,1 % SW Přijímač – fₗₘ, dolní mezní frekvence 0,1 MHz až 25 MHz CMC 3,3 % Přijímač – fᵤₘ, horní mezní frekvence 0,1 MHz až 25 MHz CMC 3,3 % Přijímač – f₀, střední frekvence 0,1 MHz až 25 MHz CMC 3,5 % Přijímač – Δf, šířka pásma 0,1 MHz až 25 MHz CMC 4,7 % Linearita časové základny pro digitální přístroje 0,5 µs až 2000 µs CMC 1,1 % + 0,05 µs A 04-55/31 (ČSN EN 12668-1:2010) Defektoskopy ultradzwiekowe Wzorcowanie – badania wlasciwosci i wad materialow Generowanie sygnalu wzorcowym generatorem Stabilnosc – pomiar amplitudy od 0 % SH do 100 % SH CMC 1,4 % SH Stabilnosc – pomiar polozenia od 0 % SW do 100 % SW CMC 1,1 % SW Odbiornik – fₗₘ, dolna czestotliwosc graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – fᵤₘ, gorna czestotliwosc graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – f₀, czestotliwosc srodkowa od 0,1 MHz do 25 MHz CMC 3,5 % Odbiornik – Δf, szerokosc pasma od 0,1 MHz do 25 MHz CMC 4,7 % Liniowosc podstawy czasu dla przyrzadow cyfrowych od 0,5 µs do 2000 µs CMC 1,1 % + 0,05 µs Ultrazvukove defektoskopy Kalibrace – zkousky vlastnosti a vad materialu Generovani signalu etalonovym generatorem Stabilita – mereni amplitudy 0 % SH az 100 % SH CMC 1,4 % SH Stabilita – mereni pozice 0 % SW az 100 % SW CMC 1,1 % SW Prijimac – fₗₘ, dolni mezni frekvence 0,1 MHz az 25 MHz CMC 3,3 % Prijimac – fᵤₘ, horni mezni frekvence 0,1 MHz az 25 MHz CMC 3,3 % Prijimac – f₀, stredni frekvence 0,1 MHz az 25 MHz CMC 3,5 % Prijimac – Δf, sirka pasma 0,1 MHz az 25 MHz CMC 4,7 % Linearita casove zakladny pro digitalni pristroje 0,5 µs az 2000 µs CMC 1,1 % + 0,05 µs A 04-55/31 (CSN EN 12668-1:2010)","search_en":"Ultrasonic flaw detectors Calibration – testing of properties and defects of materials Signal generation with a standard generator Stability – amplitude measurement 0 % SH to 100 % SH CMC 1,4 % SH Stability – position measurement 0 % SW to 100 % SW CMC 1,1 % SW Receiver – fₗₘ, lower cut-off frequency 0,1 MHz to 25 MHz CMC 3,3 % Receiver – fᵤₘ, upper cut-off frequency 0,1 MHz to 25 MHz CMC 3,3 % Receiver – f₀, centre frequency 0,1 MHz to 25 MHz CMC 3,5 % Receiver – Δf, bandwidth 0,1 MHz to 25 MHz CMC 4,7 % Time base linearity for digital instruments 0,5 µs to 2000 µs CMC 1,1 % + 0,05 µs A 04-55/31 (ČSN EN 12668-1:2010)","search_zh":"超声波探伤仪 校准 – 材料性能和缺陷检测 用标准信号发生器产生信号 稳定性 – 幅度测量 0 % SH 至 100 % SH CMC 1,4 % SH 稳定性 – 位置测量 0 % SW 至 100 % SW CMC 1,1 % SW 接收器 – fₗₘ，下限截止频率 0,1 MHz 至 25 MHz CMC 3,3 % 接收器 – fᵤₘ，上限截止频率 0,1 MHz 至 25 MHz CMC 3,3 % 接收器 – f₀，中心频率 0,1 MHz 至 25 MHz CMC 3,5 % 接收器 – Δf，带宽 0,1 MHz 至 25 MHz CMC 4,7 % 数字仪器时基线性 0,5 µs 至 2000 µs CMC 1,1 % + 0,05 µs A 04-55/31 (ČSN EN 12668-1:2010)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ccd5724ad78a19acf3a9ef17","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"1","test_object":"Defektoskopy ultradźwiękowe","test_object_en":"Ultrasonic flaw detectors","test_object_zh":"超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Nadajnik – amplituda napięcia impulsu","range":"od 1 V do 400 V","cmc":"3,2 %"},{"name":"Nadajnik – amplituda zaniku impulsu","range":"od 1 V do 400 V","cmc":"3,2 %"},{"name":"Nadajnik – czas narastania impulsu","range":"od 0 ns do 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Nadajnik – czas trwania impulsu","range":"od 0 ns do 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_en":[{"name":"Transmitter – pulse voltage amplitude","range":"1 V to 400 V","cmc":"3,2 %"},{"name":"Transmitter – pulse reverberation amplitude","range":"1 V to 400 V","cmc":"3,2 %"},{"name":"Transmitter – pulse rise time","range":"0 ns to 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Transmitter – pulse duration","range":"0 ns to 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_zh":[{"name":"发射器 – 脉冲电压幅度","range":"1 V 至 400 V","cmc":"3,2 %"},{"name":"发射器 – 脉冲余振幅度","range":"1 V 至 400 V","cmc":"3,2 %"},{"name":"发射器 – 脉冲上升时间","range":"0 ns 至 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"发射器 – 脉冲持续时间","range":"0 ns 至 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_cs":[{"name":"Vysílač – Amplituda napětí impulzu","range":"1 V až 400 V","cmc":"3,2 %"},{"name":"Vysílač – Amplituda doběhu impulzu","range":"1 V až 400 V","cmc":"3,2 %"},{"name":"Vysílač – Doba náběhu impulzu","range":"0 ns až 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Vysílač – Doba trvání impulzu","range":"0 ns až 500 ns","cmc":"2,7 % + 2,4 ns"}],"technique":"Bezpośredni pomiar sygnału wzorcowym oscyloskopem","technique_en":"Direct measurement of the signal with a standard oscilloscope","technique_zh":"用标准示波器直接测量信号","technique_cs":"Přímé měření signálu etalonovým osciloskopem","techniques":["Bezpośredni pomiar sygnału wzorcowym oscyloskopem"],"techniques_en":["Direct measurement of the signal with a standard oscilloscope"],"techniques_zh":["用标准示波器直接测量信号"],"techniques_cs":["Přímé měření signálu etalonovým osciloskopem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nNadajnik – amplituda napięcia impulsu od 1 V do 400 V CMC 3,2 %\nNadajnik – amplituda zaniku impulsu od 1 V do 400 V CMC 3,2 %\nNadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns\nNadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns\nBezpośredni pomiar sygnału wzorcowym oscyloskopem","reference":"A 04-55/31 (ČSN EN 12668-1:2010)","norm_bases":["A 04-55/31","ČSN EN 12668-1:2010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe Wzorcowanie – badania właściwości i wad materiałów Bezpośredni pomiar sygnału wzorcowym oscyloskopem Nadajnik – amplituda napięcia impulsu od 1 V do 400 V CMC 3,2 % Nadajnik – amplituda zaniku impulsu od 1 V do 400 V CMC 3,2 % Nadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Nadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Ultrazvukové defektoskopy Kalibrace – zkoušky vlastností a vad materiálů Přímé měření signálu etalonovým osciloskopem Vysílač – Amplituda napětí impulzu 1 V až 400 V CMC 3,2 % Vysílač – Amplituda doběhu impulzu 1 V až 400 V CMC 3,2 % Vysílač – Doba náběhu impulzu 0 ns až 500 ns CMC 2,7 % + 2,4 ns Vysílač – Doba trvání impulzu 0 ns až 500 ns CMC 2,7 % + 2,4 ns A 04-55/31 (ČSN EN 12668-1:2010) Defektoskopy ultradzwiekowe Wzorcowanie – badania wlasciwosci i wad materialow Bezposredni pomiar sygnalu wzorcowym oscyloskopem Nadajnik – amplituda napiecia impulsu od 1 V do 400 V CMC 3,2 % Nadajnik – amplituda zaniku impulsu od 1 V do 400 V CMC 3,2 % Nadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Nadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Ultrazvukove defektoskopy Kalibrace – zkousky vlastnosti a vad materialu Prime mereni signalu etalonovym osciloskopem Vysilac – Amplituda napeti impulzu 1 V az 400 V CMC 3,2 % Vysilac – Amplituda dobehu impulzu 1 V az 400 V CMC 3,2 % Vysilac – Doba nabehu impulzu 0 ns az 500 ns CMC 2,7 % + 2,4 ns Vysilac – Doba trvani impulzu 0 ns az 500 ns CMC 2,7 % + 2,4 ns A 04-55/31 (CSN EN 12668-1:2010)","search_en":"Ultrasonic flaw detectors Calibration – testing of properties and defects of materials Direct measurement of the signal with a standard oscilloscope Transmitter – pulse voltage amplitude 1 V to 400 V CMC 3,2 % Transmitter – pulse reverberation amplitude 1 V to 400 V CMC 3,2 % Transmitter – pulse rise time 0 ns to 500 ns CMC 2,7 % + 2,4 ns Transmitter – pulse duration 0 ns to 500 ns CMC 2,7 % + 2,4 ns A 04-55/31 (ČSN EN 12668-1:2010)","search_zh":"超声波探伤仪 校准 – 材料性能和缺陷检测 用标准示波器直接测量信号 发射器 – 脉冲电压幅度 1 V 至 400 V CMC 3,2 % 发射器 – 脉冲余振幅度 1 V 至 400 V CMC 3,2 % 发射器 – 脉冲上升时间 0 ns 至 500 ns CMC 2,7 % + 2,4 ns 发射器 – 脉冲持续时间 0 ns 至 500 ns CMC 2,7 % + 2,4 ns A 04-55/31 (ČSN EN 12668-1:2010)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bbb10057f4011b15872c8de8","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"1","test_object":"Defektoskopy ultradźwiękowe","test_object_en":"Ultrasonic flaw detectors","test_object_zh":"超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Odbiornik – równoważny poziom szumów na wejściu","range":"od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"parameters_en":[{"name":"Receiver – equivalent input noise level","range":"10⁻¹² V/√Hz to 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"parameters_zh":[{"name":"接收器 – 等效输入噪声电平","range":"10⁻¹² V/√Hz 至 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"parameters_cs":[{"name":"Přijímač – ekvivalentní úroveň šumu na vstupu","range":"10⁻¹² V/√Hz až 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"technique":"Bezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem","technique_en":"Direct measurement of the signal with a standard oscilloscope, comparison with a standard attenuator","technique_zh":"用标准示波器直接测量信号，与标准衰减器比较","technique_cs":"Přímé měření signálu etalonovým osciloskopem, porovnání s etalonovým atenuátorem","techniques":["Bezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem"],"techniques_en":["Direct measurement of the signal with a standard oscilloscope, comparison with a standard attenuator"],"techniques_zh":["用标准示波器直接测量信号，与标准衰减器比较"],"techniques_cs":["Přímé měření signálu etalonovým osciloskopem, porovnání s etalonovým atenuátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nOdbiornik – równoważny poziom szumów na wejściu od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz\nBezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem","reference":"A 04-55/31 (ČSN EN 12668-1:2010)","norm_bases":["A 04-55/31","ČSN EN 12668-1:2010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe Wzorcowanie – badania właściwości i wad materiałów Bezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem Odbiornik – równoważny poziom szumów na wejściu od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz Ultrazvukové defektoskopy Kalibrace – zkoušky vlastností a vad materiálů Přímé měření signálu etalonovým osciloskopem, porovnání s etalonovým atenuátorem Přijímač – ekvivalentní úroveň šumu na vstupu 10⁻¹² V/√Hz až 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/31 (ČSN EN 12668-1:2010) Defektoskopy ultradzwiekowe Wzorcowanie – badania wlasciwosci i wad materialow Bezposredni pomiar sygnalu wzorcowym oscyloskopem, porownanie z wzorcowym tlumikiem Odbiornik – rownowazny poziom szumow na wejsciu od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz Ultrazvukove defektoskopy Kalibrace – zkousky vlastnosti a vad materialu Prime mereni signalu etalonovym osciloskopem, porovnani s etalonovym atenuatorem Prijimac – ekvivalentni uroven sumu na vstupu 10⁻¹² V/√Hz az 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/31 (CSN EN 12668-1:2010)","search_en":"Ultrasonic flaw detectors Calibration – testing of properties and defects of materials Direct measurement of the signal with a standard oscilloscope, comparison with a standard attenuator Receiver – equivalent input noise level 10⁻¹² V/√Hz to 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/31 (ČSN EN 12668-1:2010)","search_zh":"超声波探伤仪 校准 – 材料性能和缺陷检测 用标准示波器直接测量信号，与标准衰减器比较 接收器 – 等效输入噪声电平 10⁻¹² V/√Hz 至 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/31 (ČSN EN 12668-1:2010)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8677f0ad6d7527bebb651ac8","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"1","test_object":"Defektoskopy ultradźwiękowe","test_object_en":"Ultrasonic flaw detectors","test_object_zh":"超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Odbiornik – dokładność tłumika","range":"od 0 dB do 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"Odbiornik – liniowość pionowa","range":"od 0 dB do 70 dB","cmc":"2,8 % + 0,2 dB"}],"parameters_en":[{"name":"Receiver – attenuator accuracy","range":"0 dB to 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"Receiver – vertical linearity","range":"0 dB to 70 dB","cmc":"2,8 % + 0,2 dB"}],"parameters_zh":[{"name":"接收器 – 衰减器准确度","range":"0 dB 至 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"接收器 – 垂直线性","range":"0 dB 至 70 dB","cmc":"2,8 % + 0,2 dB"}],"parameters_cs":[{"name":"Přijímač – přesnost atenuátoru","range":"0 dB až 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"Přijímač – vertikální linearita","range":"0 dB až 70 dB","cmc":"2,8 % + 0,2 dB"}],"technique":"Porównanie z wzorcowym tłumikiem","technique_en":"Comparison with a standard attenuator","technique_zh":"与标准衰减器比较","technique_cs":"Porovnání s etalonovým atenuátorem","techniques":["Porównanie z wzorcowym tłumikiem"],"techniques_en":["Comparison with a standard attenuator"],"techniques_zh":["与标准衰减器比较"],"techniques_cs":["Porovnání s etalonovým atenuátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nOdbiornik – dokładność tłumika od 0 dB do 70 dB CMC 2,8 % + 0,2 dB\nOdbiornik – liniowość pionowa od 0 dB do 70 dB CMC 2,8 % + 0,2 dB\nPorównanie z wzorcowym tłumikiem","reference":"A 04-55/31 (ČSN EN 12668-1:2010)","norm_bases":["A 04-55/31","ČSN EN 12668-1:2010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe Wzorcowanie – badania właściwości i wad materiałów Porównanie z wzorcowym tłumikiem Odbiornik – dokładność tłumika od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Odbiornik – liniowość pionowa od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Ultrazvukové defektoskopy Kalibrace – zkoušky vlastností a vad materiálů Porovnání s etalonovým atenuátorem Přijímač – přesnost atenuátoru 0 dB až 70 dB CMC 2,8 % + 0,2 dB Přijímač – vertikální linearita 0 dB až 70 dB CMC 2,8 % + 0,2 dB A 04-55/31 (ČSN EN 12668-1:2010) Defektoskopy ultradzwiekowe Wzorcowanie – badania wlasciwosci i wad materialow Porownanie z wzorcowym tlumikiem Odbiornik – dokladnosc tlumika od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Odbiornik – liniowosc pionowa od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Ultrazvukove defektoskopy Kalibrace – zkousky vlastnosti a vad materialu Porovnani s etalonovym atenuatorem Prijimac – presnost atenuatoru 0 dB az 70 dB CMC 2,8 % + 0,2 dB Prijimac – vertikalni linearita 0 dB az 70 dB CMC 2,8 % + 0,2 dB A 04-55/31 (CSN EN 12668-1:2010)","search_en":"Ultrasonic flaw detectors Calibration – testing of properties and defects of materials Comparison with a standard attenuator Receiver – attenuator accuracy 0 dB to 70 dB CMC 2,8 % + 0,2 dB Receiver – vertical linearity 0 dB to 70 dB CMC 2,8 % + 0,2 dB A 04-55/31 (ČSN EN 12668-1:2010)","search_zh":"超声波探伤仪 校准 – 材料性能和缺陷检测 与标准衰减器比较 接收器 – 衰减器准确度 0 dB 至 70 dB CMC 2,8 % + 0,2 dB 接收器 – 垂直线性 0 dB 至 70 dB CMC 2,8 % + 0,2 dB A 04-55/31 (ČSN EN 12668-1:2010)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b0095d710fe5d7d94833c6be","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"2","test_object":"Grubościomierze ultradźwiękowe","test_object_en":"Ultrasonic thickness gauges","test_object_zh":"超声波测厚仪","test_object_cs":"Ultrazvukové tloušťkoměry","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Ostrzeżenie o rozładowaniu baterii","range":"od 1 V do 20 V","cmc":"0,85 %"}],"parameters_en":[{"name":"Low battery warning","range":"1 V to 20 V","cmc":"0,85 %"}],"parameters_zh":[{"name":"电池电量低警告","range":"1 V 至 20 V","cmc":"0,85 %"}],"parameters_cs":[{"name":"Varování před vybitím baterie","range":"1 V až 20 V","cmc":"0,85 %"}],"technique":"Bezpośredni pomiar napięcia i prądu wzorcowym multimetrem","technique_en":"Direct measurement of voltage and current with a standard multimeter","technique_zh":"用标准万用表直接测量电压和电流","technique_cs":"Přímé měření napětí a proudu etalonovým multimetrem","techniques":["Bezpośredni pomiar napięcia i prądu wzorcowym multimetrem"],"techniques_en":["Direct measurement of voltage and current with a standard multimeter"],"techniques_zh":["用标准万用表直接测量电压和电流"],"techniques_cs":["Přímé měření napětí a proudu etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nOstrzeżenie o rozładowaniu baterii od 1 V do 20 V CMC 0,85 %\nBezpośredni pomiar napięcia i prądu wzorcowym multimetrem","reference":"A 04-55/01 (ČSN EN ISO 16831)","norm_bases":["A 04-55/01","ČSN EN ISO 16831"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze ultradźwiękowe Wzorcowanie – badania właściwości i wad materiałów Bezpośredni pomiar napięcia i prądu wzorcowym multimetrem Ostrzeżenie o rozładowaniu baterii od 1 V do 20 V CMC 0,85 % Ultrazvukové tloušťkoměry Kalibrace – zkoušky vlastností a vad materiálů Přímé měření napětí a proudu etalonovým multimetrem Varování před vybitím baterie 1 V až 20 V CMC 0,85 % A 04-55/01 (ČSN EN ISO 16831) Grubosciomierze ultradzwiekowe Wzorcowanie – badania wlasciwosci i wad materialow Bezposredni pomiar napiecia i pradu wzorcowym multimetrem Ostrzezenie o rozladowaniu baterii od 1 V do 20 V CMC 0,85 % Ultrazvukove tloustkomery Kalibrace – zkousky vlastnosti a vad materialu Prime mereni napeti a proudu etalonovym multimetrem Varovani pred vybitim baterie 1 V az 20 V CMC 0,85 % A 04-55/01 (CSN EN ISO 16831)","search_en":"Ultrasonic thickness gauges Calibration – testing of properties and defects of materials Direct measurement of voltage and current with a standard multimeter Low battery warning 1 V to 20 V CMC 0,85 % A 04-55/01 (ČSN EN ISO 16831)","search_zh":"超声波测厚仪 校准 – 材料性能和缺陷检测 用标准万用表直接测量电压和电流 电池电量低警告 1 V 至 20 V CMC 0,85 % A 04-55/01 (ČSN EN ISO 16831)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"515757b75b4d7b44ca009b92","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"2","test_object":"Grubościomierze ultradźwiękowe","test_object_en":"Ultrasonic thickness gauges","test_object_zh":"超声波测厚仪","test_object_cs":"Ultrazvukové tloušťkoměry","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Nadajnik – częstotliwość powtarzania impulsów","range":"od 0,1 ms do 10 ms","cmc":"0,65 %"},{"name":"Nadajnik – amplituda napięcia impulsu","range":"od 1 V do 400 V","cmc":"3,3 %"},{"name":"Nadajnik – czas narastania impulsu","range":"od 0 ns do 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Nadajnik – czas trwania impulsu","range":"od 0 ns do 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_en":[{"name":"Transmitter – pulse repetition frequency","range":"0,1 ms to 10 ms","cmc":"0,65 %"},{"name":"Transmitter – pulse voltage amplitude","range":"1 V to 400 V","cmc":"3,3 %"},{"name":"Transmitter – pulse rise time","range":"0 ns to 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Transmitter – pulse duration","range":"0 ns to 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_zh":[{"name":"发射器 – 脉冲重复频率","range":"0,1 ms 至 10 ms","cmc":"0,65 %"},{"name":"发射器 – 脉冲电压幅度","range":"1 V 至 400 V","cmc":"3,3 %"},{"name":"发射器 – 脉冲上升时间","range":"0 ns 至 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"发射器 – 脉冲持续时间","range":"0 ns 至 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_cs":[{"name":"Vysílač – Opakovací frekvence impulzů","range":"0,1 ms až 10 ms","cmc":"0,65 %"},{"name":"Vysílač – Amplituda napětí impulzu","range":"1 V až 400 V","cmc":"3,3 %"},{"name":"Vysílač – Doba náběhu impulzu","range":"0 ns až 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Vysílač – Doba trvání impulzu","range":"0 ns až 500 ns","cmc":"2,7 % + 2,4 ns"}],"technique":"Bezpośredni pomiar sygnału wzorcowym oscyloskopem","technique_en":"Direct measurement of the signal with a standard oscilloscope","technique_zh":"用标准示波器直接测量信号","technique_cs":"Přímé měření signálu etalonovým osciloskopem","techniques":["Bezpośredni pomiar sygnału wzorcowym oscyloskopem"],"techniques_en":["Direct measurement of the signal with a standard oscilloscope"],"techniques_zh":["用标准示波器直接测量信号"],"techniques_cs":["Přímé měření signálu etalonovým osciloskopem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nNadajnik – częstotliwość powtarzania impulsów od 0,1 ms do 10 ms CMC 0,65 %\nNadajnik – amplituda napięcia impulsu od 1 V do 400 V CMC 3,3 %\nNadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns\nNadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns\nBezpośredni pomiar sygnału wzorcowym oscyloskopem","reference":"A 04-55/01 (ČSN EN ISO 16831)","norm_bases":["A 04-55/01","ČSN EN ISO 16831"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze ultradźwiękowe Wzorcowanie – badania właściwości i wad materiałów Bezpośredni pomiar sygnału wzorcowym oscyloskopem Nadajnik – częstotliwość powtarzania impulsów od 0,1 ms do 10 ms CMC 0,65 % Nadajnik – amplituda napięcia impulsu od 1 V do 400 V CMC 3,3 % Nadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Nadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Ultrazvukové tloušťkoměry Kalibrace – zkoušky vlastností a vad materiálů Přímé měření signálu etalonovým osciloskopem Vysílač – Opakovací frekvence impulzů 0,1 ms až 10 ms CMC 0,65 % Vysílač – Amplituda napětí impulzu 1 V až 400 V CMC 3,3 % Vysílač – Doba náběhu impulzu 0 ns až 500 ns CMC 2,7 % + 2,4 ns Vysílač – Doba trvání impulzu 0 ns až 500 ns CMC 2,7 % + 2,4 ns A 04-55/01 (ČSN EN ISO 16831) Grubosciomierze ultradzwiekowe Wzorcowanie – badania wlasciwosci i wad materialow Bezposredni pomiar sygnalu wzorcowym oscyloskopem Nadajnik – czestotliwosc powtarzania impulsow od 0,1 ms do 10 ms CMC 0,65 % Nadajnik – amplituda napiecia impulsu od 1 V do 400 V CMC 3,3 % Nadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Nadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Ultrazvukove tloustkomery Kalibrace – zkousky vlastnosti a vad materialu Prime mereni signalu etalonovym osciloskopem Vysilac – Opakovaci frekvence impulzu 0,1 ms az 10 ms CMC 0,65 % Vysilac – Amplituda napeti impulzu 1 V az 400 V CMC 3,3 % Vysilac – Doba nabehu impulzu 0 ns az 500 ns CMC 2,7 % + 2,4 ns Vysilac – Doba trvani impulzu 0 ns az 500 ns CMC 2,7 % + 2,4 ns A 04-55/01 (CSN EN ISO 16831)","search_en":"Ultrasonic thickness gauges Calibration – testing of properties and defects of materials Direct measurement of the signal with a standard oscilloscope Transmitter – pulse repetition frequency 0,1 ms to 10 ms CMC 0,65 % Transmitter – pulse voltage amplitude 1 V to 400 V CMC 3,3 % Transmitter – pulse rise time 0 ns to 500 ns CMC 2,7 % + 2,4 ns Transmitter – pulse duration 0 ns to 500 ns CMC 2,7 % + 2,4 ns A 04-55/01 (ČSN EN ISO 16831)","search_zh":"超声波测厚仪 校准 – 材料性能和缺陷检测 用标准示波器直接测量信号 发射器 – 脉冲重复频率 0,1 ms 至 10 ms CMC 0,65 % 发射器 – 脉冲电压幅度 1 V 至 400 V CMC 3,3 % 发射器 – 脉冲上升时间 0 ns 至 500 ns CMC 2,7 % + 2,4 ns 发射器 – 脉冲持续时间 0 ns 至 500 ns CMC 2,7 % + 2,4 ns A 04-55/01 (ČSN EN ISO 16831)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"350e47931638306103511608","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"2","test_object":"Grubościomierze ultradźwiękowe","test_object_en":"Ultrasonic thickness gauges","test_object_zh":"超声波测厚仪","test_object_cs":"Ultrazvukové tloušťkoměry","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Min. i maks. mierzalna grubość","range":"od 1 mm do 100 mm","cmc":"0,04 mm"},{"name":"Rozdzielczość grubości; gr. (9,4 do 9,8) mm","range":"0,1 mm","cmc":"0,04 mm"}],"parameters_en":[{"name":"Min. and max. measurable thickness","range":"1 mm to 100 mm","cmc":"0,04 mm"},{"name":"Thickness resolution; thk. (9.4 to 9.8) mm","range":"0,1 mm","cmc":"0,04 mm"}],"parameters_zh":[{"name":"最小和最大可测厚度","range":"1 mm 至 100 mm","cmc":"0,04 mm"},{"name":"厚度分辨率；厚度 (9,4 至 9,8) mm","range":"0,1 mm","cmc":"0,04 mm"}],"parameters_cs":[{"name":"Min. a max. změřitelná tloušťka","range":"1 mm až 100 mm","cmc":"0,04 mm"},{"name":"Rozlišovací schopnost tloušťky; tl. (9,4 až 9,8) mm","range":"0,1 mm","cmc":"0,04 mm"}],"technique":"Porównanie z wzorcem długości","technique_en":"Comparison with a length standard","technique_zh":"与长度标准比较","technique_cs":"Porovnání s etalonem délky","techniques":["Porównanie z wzorcem długości"],"techniques_en":["Comparison with a length standard"],"techniques_zh":["与长度标准比较"],"techniques_cs":["Porovnání s etalonem délky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nMin. i maks. mierzalna grubość od 1 mm do 100 mm CMC 0,04 mm\nRozdzielczość grubości; gr. (9,4 do 9,8) mm 0,1 mm CMC 0,04 mm\nPorównanie z wzorcem długości","reference":"A 04-55/01 (ČSN EN ISO 16831)","norm_bases":["A 04-55/01","ČSN EN ISO 16831"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grubościomierze ultradźwiękowe Wzorcowanie – badania właściwości i wad materiałów Porównanie z wzorcem długości Min. i maks. mierzalna grubość od 1 mm do 100 mm CMC 0,04 mm Rozdzielczość grubości; gr. (9,4 do 9,8) mm 0,1 mm CMC 0,04 mm Ultrazvukové tloušťkoměry Kalibrace – zkoušky vlastností a vad materiálů Porovnání s etalonem délky Min. a max. změřitelná tloušťka 1 mm až 100 mm CMC 0,04 mm Rozlišovací schopnost tloušťky; tl. (9,4 až 9,8) mm 0,1 mm CMC 0,04 mm A 04-55/01 (ČSN EN ISO 16831) Grubosciomierze ultradzwiekowe Wzorcowanie – badania wlasciwosci i wad materialow Porownanie z wzorcem dlugosci Min. i maks. mierzalna grubosc od 1 mm do 100 mm CMC 0,04 mm Rozdzielczosc grubosci; gr. (9,4 do 9,8) mm 0,1 mm CMC 0,04 mm Ultrazvukove tloustkomery Kalibrace – zkousky vlastnosti a vad materialu Porovnani s etalonem delky Min. a max. zmeritelna tloustka 1 mm az 100 mm CMC 0,04 mm Rozlisovaci schopnost tloustky; tl. (9,4 az 9,8) mm 0,1 mm CMC 0,04 mm A 04-55/01 (CSN EN ISO 16831)","search_en":"Ultrasonic thickness gauges Calibration – testing of properties and defects of materials Comparison with a length standard Min. and max. measurable thickness 1 mm to 100 mm CMC 0,04 mm Thickness resolution; thk. (9.4 to 9.8) mm 0,1 mm CMC 0,04 mm A 04-55/01 (ČSN EN ISO 16831)","search_zh":"超声波测厚仪 校准 – 材料性能和缺陷检测 与长度标准比较 最小和最大可测厚度 1 mm 至 100 mm CMC 0,04 mm 厚度分辨率；厚度 (9,4 至 9,8) mm 0,1 mm CMC 0,04 mm A 04-55/01 (ČSN EN ISO 16831)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"45b59945efd649f4989bb4d3","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"3","test_object":"Styczne pole magnetyczne / Magnesy ręczne","test_object_en":"Tangential magnetic field / Hand-held magnets","test_object_zh":"切向磁场 / 手持磁铁","test_object_cs":"Tangenciální magnetické pole / Ruční magnety","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"50 Hz","range":"od 1,5 kA/m do 15 kA/m","cmc":"7,7 %"}],"parameters_en":[{"name":"50 Hz","range":"1,5 kA/m to 15 kA/m","cmc":"7,7 %"}],"parameters_zh":[{"name":"50 Hz","range":"1,5 kA/m 至 15 kA/m","cmc":"7,7 %"}],"parameters_cs":[{"name":"50 Hz","range":"1,5 kA/m až 15 kA/m","cmc":"7,7 %"}],"technique":"Pomiar teslomierzem","technique_en":"Measurement with a teslameter","technique_zh":"用特斯拉计测量","technique_cs":"Měření teslametrem","techniques":["Pomiar teslomierzem"],"techniques_en":["Measurement with a teslameter"],"techniques_zh":["用特斯拉计测量"],"techniques_cs":["Měření teslametrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\n50 Hz od 1,5 kA/m do 15 kA/m CMC 7,7 %\nPomiar teslomierzem","reference":"A 04-53/41a (ČSN EN ISO 9934-3)","norm_bases":["A 04-53/41a","ČSN EN ISO 9934-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Styczne pole magnetyczne / Magnesy ręczne Wzorcowanie – badania właściwości i wad materiałów Pomiar teslomierzem 50 Hz od 1,5 kA/m do 15 kA/m CMC 7,7 % Tangenciální magnetické pole / Ruční magnety Kalibrace – zkoušky vlastností a vad materiálů Měření teslametrem 50 Hz 1,5 kA/m až 15 kA/m CMC 7,7 % A 04-53/41a (ČSN EN ISO 9934-3) Styczne pole magnetyczne / Magnesy reczne Wzorcowanie – badania wlasciwosci i wad materialow Pomiar teslomierzem 50 Hz od 1,5 kA/m do 15 kA/m CMC 7,7 % Tangencialni magneticke pole / Rucni magnety Kalibrace – zkousky vlastnosti a vad materialu Mereni teslametrem 50 Hz 1,5 kA/m az 15 kA/m CMC 7,7 % A 04-53/41a (CSN EN ISO 9934-3)","search_en":"Tangential magnetic field / Hand-held magnets Calibration – testing of properties and defects of materials Measurement with a teslameter 50 Hz 1,5 kA/m to 15 kA/m CMC 7,7 % A 04-53/41a (ČSN EN ISO 9934-3)","search_zh":"切向磁场 / 手持磁铁 校准 – 材料性能和缺陷检测 用特斯拉计测量 50 Hz 1,5 kA/m 至 15 kA/m CMC 7,7 % A 04-53/41a (ČSN EN ISO 9934-3)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08bd02d78f03925bb3e0fd5b","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"4","test_object":"Prąd AC / Generatory prądowe","test_object_en":"AC current / Current generators","test_object_zh":"交流电流 / 电流发生器","test_object_cs":"Proud AC / Proudové generátory","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"50 Hz","range":"od 0 A do 300 A","cmc":"3,0 % + 2,9 A"},{"name":"50 Hz","range":"od 300 A do 3000 A","cmc":"3,0 % + 29 A"}],"parameters_en":[{"name":"50 Hz","range":"0 A to 300 A","cmc":"3,0 % + 2,9 A"},{"name":"50 Hz","range":"300 A to 3000 A","cmc":"3,0 % + 29 A"}],"parameters_zh":[{"name":"50 Hz","range":"0 A 至 300 A","cmc":"3,0 % + 2,9 A"},{"name":"50 Hz","range":"300 A 至 3000 A","cmc":"3,0 % + 29 A"}],"parameters_cs":[{"name":"50 Hz","range":"0 A až 300 A","cmc":"3,0 % + 2,9 A"},{"name":"50 Hz","range":"300 A až 3000 A","cmc":"3,0 % + 29 A"}],"technique":"Porównanie z cęgowym przetwornikiem prądu","technique_en":"Comparison with a clamp-on current transducer","technique_zh":"与钳形电流互感器比较","technique_cs":"Porovnání s kleštovým proudovým převodníkem","techniques":["Porównanie z cęgowym przetwornikiem prądu"],"techniques_en":["Comparison with a clamp-on current transducer"],"techniques_zh":["与钳形电流互感器比较"],"techniques_cs":["Porovnání s kleštovým proudovým převodníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\n50 Hz od 0 A do 300 A CMC 3,0 % + 2,9 A\n50 Hz od 300 A do 3000 A CMC 3,0 % + 29 A\nPorównanie z cęgowym przetwornikiem prądu","reference":"A 04-53/51a (ČSN EN ISO 9934-3)","norm_bases":["A 04-53/51a","ČSN EN ISO 9934-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd AC / Generatory prądowe Wzorcowanie – badania właściwości i wad materiałów Porównanie z cęgowym przetwornikiem prądu 50 Hz od 0 A do 300 A CMC 3,0 % + 2,9 A 50 Hz od 300 A do 3000 A CMC 3,0 % + 29 A Proud AC / Proudové generátory Kalibrace – zkoušky vlastností a vad materiálů Porovnání s kleštovým proudovým převodníkem 50 Hz 0 A až 300 A CMC 3,0 % + 2,9 A 50 Hz 300 A až 3000 A CMC 3,0 % + 29 A A 04-53/51a (ČSN EN ISO 9934-3) Prad AC / Generatory pradowe Wzorcowanie – badania wlasciwosci i wad materialow Porownanie z cegowym przetwornikiem pradu 50 Hz od 0 A do 300 A CMC 3,0 % + 2,9 A 50 Hz od 300 A do 3000 A CMC 3,0 % + 29 A Proud AC / Proudove generatory Kalibrace – zkousky vlastnosti a vad materialu Porovnani s klestovym proudovym prevodnikem 50 Hz 0 A az 300 A CMC 3,0 % + 2,9 A 50 Hz 300 A az 3000 A CMC 3,0 % + 29 A A 04-53/51a (CSN EN ISO 9934-3)","search_en":"AC current / Current generators Calibration – testing of properties and defects of materials Comparison with a clamp-on current transducer 50 Hz 0 A to 300 A CMC 3,0 % + 2,9 A 50 Hz 300 A to 3000 A CMC 3,0 % + 29 A A 04-53/51a (ČSN EN ISO 9934-3)","search_zh":"交流电流 / 电流发生器 校准 – 材料性能和缺陷检测 与钳形电流互感器比较 50 Hz 0 A 至 300 A CMC 3,0 % + 2,9 A 50 Hz 300 A 至 3000 A CMC 3,0 % + 29 A A 04-53/51a (ČSN EN ISO 9934-3)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09418cb03d3181789889c66a","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"5","test_object":"Stacjonarne urządzenia magnesujące","test_object_en":"Stationary magnetizing equipment","test_object_zh":"固定式磁化设备","test_object_cs":"Stacionární magnetizační zařízení","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Styczne pole magnetyczne; 50 Hz","range":"od 2 kA/m do 6 kA/m","cmc":"7,7 %"}],"parameters_en":[{"name":"Tangential magnetic field; 50 Hz","range":"2 kA/m to 6 kA/m","cmc":"7,7 %"}],"parameters_zh":[{"name":"切向磁场；50 Hz","range":"2 kA/m 至 6 kA/m","cmc":"7,7 %"}],"parameters_cs":[{"name":"Tangenciální magnetické pole; 50 Hz","range":"2 kA/m až 6 kA/m","cmc":"7,7 %"}],"technique":"Pomiar teslomierzem","technique_en":"Measurement with a teslameter","technique_zh":"用特斯拉计测量","technique_cs":"Měření teslametrem","techniques":["Pomiar teslomierzem"],"techniques_en":["Measurement with a teslameter"],"techniques_zh":["用特斯拉计测量"],"techniques_cs":["Měření teslametrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nStyczne pole magnetyczne; 50 Hz od 2 kA/m do 6 kA/m CMC 7,7 %\nPomiar teslomierzem","reference":"A 04-53/61a (ČSN EN ISO 9934-3)","norm_bases":["A 04-53/61a","ČSN EN ISO 9934-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stacjonarne urządzenia magnesujące Wzorcowanie – badania właściwości i wad materiałów Pomiar teslomierzem Styczne pole magnetyczne; 50 Hz od 2 kA/m do 6 kA/m CMC 7,7 % Stacionární magnetizační zařízení Kalibrace – zkoušky vlastností a vad materiálů Měření teslametrem Tangenciální magnetické pole; 50 Hz 2 kA/m až 6 kA/m CMC 7,7 % A 04-53/61a (ČSN EN ISO 9934-3) Stacjonarne urzadzenia magnesujace Wzorcowanie – badania wlasciwosci i wad materialow Pomiar teslomierzem Styczne pole magnetyczne; 50 Hz od 2 kA/m do 6 kA/m CMC 7,7 % Stacionarni magnetizacni zarizeni Kalibrace – zkousky vlastnosti a vad materialu Mereni teslametrem Tangencialni magneticke pole; 50 Hz 2 kA/m az 6 kA/m CMC 7,7 % A 04-53/61a (CSN EN ISO 9934-3)","search_en":"Stationary magnetizing equipment Calibration – testing of properties and defects of materials Measurement with a teslameter Tangential magnetic field; 50 Hz 2 kA/m to 6 kA/m CMC 7,7 % A 04-53/61a (ČSN EN ISO 9934-3)","search_zh":"固定式磁化设备 校准 – 材料性能和缺陷检测 用特斯拉计测量 切向磁场；50 Hz 2 kA/m 至 6 kA/m CMC 7,7 % A 04-53/61a (ČSN EN ISO 9934-3)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61e7624dbc541b27a2c85e53","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"5","test_object":"Stacjonarne urządzenia magnesujące","test_object_en":"Stationary magnetizing equipment","test_object_zh":"固定式磁化设备","test_object_cs":"Stacionární magnetizační zařízení","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Prąd AC; 50 Hz","range":"od 0 A do 300 A","cmc":"3,0 % + 2,9 A"},{"name":"Prąd AC; 50 Hz","range":"od 300 A do 3000 A","cmc":"3,0 % + 29 A"}],"parameters_en":[{"name":"AC current; 50 Hz","range":"0 A to 300 A","cmc":"3,0 % + 2,9 A"},{"name":"AC current; 50 Hz","range":"300 A to 3000 A","cmc":"3,0 % + 29 A"}],"parameters_zh":[{"name":"交流电流；50 Hz","range":"0 A 至 300 A","cmc":"3,0 % + 2,9 A"},{"name":"交流电流；50 Hz","range":"300 A 至 3000 A","cmc":"3,0 % + 29 A"}],"parameters_cs":[{"name":"Proud AC; 50 Hz","range":"0 A až 300 A","cmc":"3,0 % + 2,9 A"},{"name":"Proud AC; 50 Hz","range":"300 A až 3000 A","cmc":"3,0 % + 29 A"}],"technique":"Porównanie z cęgowym przetwornikiem prądu","technique_en":"Comparison with a clamp-on current transducer","technique_zh":"与钳形电流互感器比较","technique_cs":"Porovnání s kleštovým proudovým převodníkem","techniques":["Porównanie z cęgowym przetwornikiem prądu"],"techniques_en":["Comparison with a clamp-on current transducer"],"techniques_zh":["与钳形电流互感器比较"],"techniques_cs":["Porovnání s kleštovým proudovým převodníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nPrąd AC; 50 Hz od 0 A do 300 A CMC 3,0 % + 2,9 A\nPrąd AC; 50 Hz od 300 A do 3000 A CMC 3,0 % + 29 A\nPorównanie z cęgowym przetwornikiem prądu","reference":"A 04-53/61a (ČSN EN ISO 9934-3)","norm_bases":["A 04-53/61a","ČSN EN ISO 9934-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stacjonarne urządzenia magnesujące Wzorcowanie – badania właściwości i wad materiałów Porównanie z cęgowym przetwornikiem prądu Prąd AC; 50 Hz od 0 A do 300 A CMC 3,0 % + 2,9 A Prąd AC; 50 Hz od 300 A do 3000 A CMC 3,0 % + 29 A Stacionární magnetizační zařízení Kalibrace – zkoušky vlastností a vad materiálů Porovnání s kleštovým proudovým převodníkem Proud AC; 50 Hz 0 A až 300 A CMC 3,0 % + 2,9 A Proud AC; 50 Hz 300 A až 3000 A CMC 3,0 % + 29 A A 04-53/61a (ČSN EN ISO 9934-3) Stacjonarne urzadzenia magnesujace Wzorcowanie – badania wlasciwosci i wad materialow Porownanie z cegowym przetwornikiem pradu Prad AC; 50 Hz od 0 A do 300 A CMC 3,0 % + 2,9 A Prad AC; 50 Hz od 300 A do 3000 A CMC 3,0 % + 29 A Stacionarni magnetizacni zarizeni Kalibrace – zkousky vlastnosti a vad materialu Porovnani s klestovym proudovym prevodnikem Proud AC; 50 Hz 0 A az 300 A CMC 3,0 % + 2,9 A Proud AC; 50 Hz 300 A az 3000 A CMC 3,0 % + 29 A A 04-53/61a (CSN EN ISO 9934-3)","search_en":"Stationary magnetizing equipment Calibration – testing of properties and defects of materials Comparison with a clamp-on current transducer AC current; 50 Hz 0 A to 300 A CMC 3,0 % + 2,9 A AC current; 50 Hz 300 A to 3000 A CMC 3,0 % + 29 A A 04-53/61a (ČSN EN ISO 9934-3)","search_zh":"固定式磁化设备 校准 – 材料性能和缺陷检测 与钳形电流互感器比较 交流电流；50 Hz 0 A 至 300 A CMC 3,0 % + 2,9 A 交流电流；50 Hz 300 A 至 3000 A CMC 3,0 % + 29 A A 04-53/61a (ČSN EN ISO 9934-3)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c8edc549ba0937e7f35707e","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"6","test_object":"Mierniki natężenia pola magnetycznego (teslomierze, gaussomierze, magnetometry)","test_object_en":"Magnetic field strength meters (teslameters, gaussmeters, magnetometers)","test_object_zh":"磁场强度测量仪（特斯拉计、高斯计、磁强计）","test_object_cs":"Měřiče intenzity magnetického pole (teslametry, gaussmetry, magnetometry)","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Styczne pole magnetyczne DC","range":"od 0,5 kA/m do 1,5 kA/m","cmc":"2,0 %"},{"name":"Styczne pole magnetyczne AC; 50 Hz","range":"od 0,5 kA/m do 1,5 kA/m","cmc":"3,0 %"},{"name":"Styczne pole magnetyczne DC","range":"od 1,5 kA/m do 30 kA/m","cmc":"0,8 %"},{"name":"Styczne pole magnetyczne AC; 50 Hz","range":"od 1,5 kA/m do 30 kA/m","cmc":"1,2 %"}],"parameters_en":[{"name":"Tangential magnetic field DC","range":"0,5 kA/m to 1,5 kA/m","cmc":"2,0 %"},{"name":"Tangential magnetic field AC; 50 Hz","range":"0,5 kA/m to 1,5 kA/m","cmc":"3,0 %"},{"name":"Tangential magnetic field DC","range":"1,5 kA/m to 30 kA/m","cmc":"0,8 %"},{"name":"Tangential magnetic field AC; 50 Hz","range":"1,5 kA/m to 30 kA/m","cmc":"1,2 %"}],"parameters_zh":[{"name":"切向磁场 DC","range":"0,5 kA/m 至 1,5 kA/m","cmc":"2,0 %"},{"name":"切向磁场 AC；50 Hz","range":"0,5 kA/m 至 1,5 kA/m","cmc":"3,0 %"},{"name":"切向磁场 DC","range":"1,5 kA/m 至 30 kA/m","cmc":"0,8 %"},{"name":"切向磁场 AC；50 Hz","range":"1,5 kA/m 至 30 kA/m","cmc":"1,2 %"}],"parameters_cs":[{"name":"Tangenciální magnetické pole DC","range":"0,5 kA/m až 1,5 kA/m","cmc":"2,0 %"},{"name":"Tangenciální magnetické pole AC; 50 Hz","range":"0,5 kA/m až 1,5 kA/m","cmc":"3,0 %"},{"name":"Tangenciální magnetické pole DC","range":"1,5 kA/m až 30 kA/m","cmc":"0,8 %"},{"name":"Tangenciální magnetické pole AC; 50 Hz","range":"1,5 kA/m až 30 kA/m","cmc":"1,2 %"}],"technique":"Porównanie z cewkowym wzorcem indukcji magnetycznej","technique_en":"Comparison with a coil standard of magnetic induction","technique_zh":"与线圈式磁感应强度标准比较","technique_cs":"Porovnání s cívkovým etalonem magnetické indukce","techniques":["Porównanie z cewkowym wzorcem indukcji magnetycznej"],"techniques_en":["Comparison with a coil standard of magnetic induction"],"techniques_zh":["与线圈式磁感应强度标准比较"],"techniques_cs":["Porovnání s cívkovým etalonem magnetické indukce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nStyczne pole magnetyczne DC od 0,5 kA/m do 1,5 kA/m CMC 2,0 %\nStyczne pole magnetyczne AC; 50 Hz od 0,5 kA/m do 1,5 kA/m CMC 3,0 %\nStyczne pole magnetyczne DC od 1,5 kA/m do 30 kA/m CMC 0,8 %\nStyczne pole magnetyczne AC; 50 Hz od 1,5 kA/m do 30 kA/m CMC 1,2 %\nPorównanie z cewkowym wzorcem indukcji magnetycznej","reference":"A 04-53/32 (ČSN EN ISO 9934-3)","norm_bases":["A 04-53/32","ČSN EN ISO 9934-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki natężenia pola magnetycznego (teslomierze, gaussomierze, magnetometry) Wzorcowanie – badania właściwości i wad materiałów Porównanie z cewkowym wzorcem indukcji magnetycznej Styczne pole magnetyczne DC od 0,5 kA/m do 1,5 kA/m CMC 2,0 % Styczne pole magnetyczne AC; 50 Hz od 0,5 kA/m do 1,5 kA/m CMC 3,0 % Styczne pole magnetyczne DC od 1,5 kA/m do 30 kA/m CMC 0,8 % Styczne pole magnetyczne AC; 50 Hz od 1,5 kA/m do 30 kA/m CMC 1,2 % Měřiče intenzity magnetického pole (teslametry, gaussmetry, magnetometry) Kalibrace – zkoušky vlastností a vad materiálů Porovnání s cívkovým etalonem magnetické indukce Tangenciální magnetické pole DC 0,5 kA/m až 1,5 kA/m CMC 2,0 % Tangenciální magnetické pole AC; 50 Hz 0,5 kA/m až 1,5 kA/m CMC 3,0 % Tangenciální magnetické pole DC 1,5 kA/m až 30 kA/m CMC 0,8 % Tangenciální magnetické pole AC; 50 Hz 1,5 kA/m až 30 kA/m CMC 1,2 % A 04-53/32 (ČSN EN ISO 9934-3) Mierniki natezenia pola magnetycznego (teslomierze, gaussomierze, magnetometry) Wzorcowanie – badania wlasciwosci i wad materialow Porownanie z cewkowym wzorcem indukcji magnetycznej Styczne pole magnetyczne DC od 0,5 kA/m do 1,5 kA/m CMC 2,0 % Styczne pole magnetyczne AC; 50 Hz od 0,5 kA/m do 1,5 kA/m CMC 3,0 % Styczne pole magnetyczne DC od 1,5 kA/m do 30 kA/m CMC 0,8 % Styczne pole magnetyczne AC; 50 Hz od 1,5 kA/m do 30 kA/m CMC 1,2 % Merice intenzity magnetickeho pole (teslametry, gaussmetry, magnetometry) Kalibrace – zkousky vlastnosti a vad materialu Porovnani s civkovym etalonem magneticke indukce Tangencialni magneticke pole DC 0,5 kA/m az 1,5 kA/m CMC 2,0 % Tangencialni magneticke pole AC; 50 Hz 0,5 kA/m az 1,5 kA/m CMC 3,0 % Tangencialni magneticke pole DC 1,5 kA/m az 30 kA/m CMC 0,8 % Tangencialni magneticke pole AC; 50 Hz 1,5 kA/m az 30 kA/m CMC 1,2 % A 04-53/32 (CSN EN ISO 9934-3)","search_en":"Magnetic field strength meters (teslameters, gaussmeters, magnetometers) Calibration – testing of properties and defects of materials Comparison with a coil standard of magnetic induction Tangential magnetic field DC 0,5 kA/m to 1,5 kA/m CMC 2,0 % Tangential magnetic field AC; 50 Hz 0,5 kA/m to 1,5 kA/m CMC 3,0 % Tangential magnetic field DC 1,5 kA/m to 30 kA/m CMC 0,8 % Tangential magnetic field AC; 50 Hz 1,5 kA/m to 30 kA/m CMC 1,2 % A 04-53/32 (ČSN EN ISO 9934-3)","search_zh":"磁场强度测量仪（特斯拉计、高斯计、磁强计） 校准 – 材料性能和缺陷检测 与线圈式磁感应强度标准比较 切向磁场 DC 0,5 kA/m 至 1,5 kA/m CMC 2,0 % 切向磁场 AC；50 Hz 0,5 kA/m 至 1,5 kA/m CMC 3,0 % 切向磁场 DC 1,5 kA/m 至 30 kA/m CMC 0,8 % 切向磁场 AC；50 Hz 1,5 kA/m 至 30 kA/m CMC 1,2 % A 04-53/32 (ČSN EN ISO 9934-3)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a7ca5609dbd51d1a2df7f919","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"7","test_object":"Defektoskopy wiroprądowe","test_object_en":"Eddy current flaw detectors","test_object_zh":"涡流探伤仪","test_object_cs":"Vířivoproudé defektoskopy","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Częstotliwość generatora","range":"od 0,1 kHz do 1000 kHz","cmc":"0,011 %"}],"parameters_en":[{"name":"Generator frequency","range":"0,1 kHz to 1000 kHz","cmc":"0,011 %"}],"parameters_zh":[{"name":"发生器频率","range":"0,1 kHz 至 1000 kHz","cmc":"0,011 %"}],"parameters_cs":[{"name":"Frekvence generátoru","range":"0,1 kHz až 1000 kHz","cmc":"0,011 %"}],"technique":"Bezpośredni pomiar sygnału wzorcowym licznikiem częstotliwości","technique_en":"Direct measurement of the signal with a standard counter","technique_zh":"用标准计数器直接测量信号","technique_cs":"Přímé měření signálu etalonovým čítačem","techniques":["Bezpośredni pomiar sygnału wzorcowym licznikiem częstotliwości"],"techniques_en":["Direct measurement of the signal with a standard counter"],"techniques_zh":["用标准计数器直接测量信号"],"techniques_cs":["Přímé měření signálu etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nCzęstotliwość generatora od 0,1 kHz do 1000 kHz CMC 0,011 %\nBezpośredni pomiar sygnału wzorcowym licznikiem częstotliwości","reference":"A 04-51/29 (ČSN EN ISO 15548-1)","norm_bases":["A 04-51/29","ČSN EN ISO 15548-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy wiroprądowe Wzorcowanie – badania właściwości i wad materiałów Bezpośredni pomiar sygnału wzorcowym licznikiem częstotliwości Częstotliwość generatora od 0,1 kHz do 1000 kHz CMC 0,011 % Vířivoproudé defektoskopy Kalibrace – zkoušky vlastností a vad materiálů Přímé měření signálu etalonovým čítačem Frekvence generátoru 0,1 kHz až 1000 kHz CMC 0,011 % A 04-51/29 (ČSN EN ISO 15548-1) Defektoskopy wiropradowe Wzorcowanie – badania wlasciwosci i wad materialow Bezposredni pomiar sygnalu wzorcowym licznikiem czestotliwosci Czestotliwosc generatora od 0,1 kHz do 1000 kHz CMC 0,011 % Virivoproude defektoskopy Kalibrace – zkousky vlastnosti a vad materialu Prime mereni signalu etalonovym citacem Frekvence generatoru 0,1 kHz az 1000 kHz CMC 0,011 % A 04-51/29 (CSN EN ISO 15548-1)","search_en":"Eddy current flaw detectors Calibration – testing of properties and defects of materials Direct measurement of the signal with a standard counter Generator frequency 0,1 kHz to 1000 kHz CMC 0,011 % A 04-51/29 (ČSN EN ISO 15548-1)","search_zh":"涡流探伤仪 校准 – 材料性能和缺陷检测 用标准计数器直接测量信号 发生器频率 0,1 kHz 至 1000 kHz CMC 0,011 % A 04-51/29 (ČSN EN ISO 15548-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"450376c5a7c20207a16de682","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"7","test_object":"Defektoskopy wiroprądowe","test_object_en":"Eddy current flaw detectors","test_object_zh":"涡流探伤仪","test_object_cs":"Vířivoproudé defektoskopy","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Odbiornik – fₗₘ, dolna częstotliwość graniczna","range":"od 1 kHz do 100 kHz","cmc":"2,4 %"},{"name":"Odbiornik – fᵤₘ, górna częstotliwość graniczna","range":"od 1 kHz do 100 kHz","cmc":"2,4 %"},{"name":"Odbiornik – f₀, częstotliwość środkowa","range":"od 1 kHz do 100 kHz","cmc":"2,5 %"},{"name":"Odbiornik – Δf, szerokość pasma","range":"od 1 kHz do 100 kHz","cmc":"5,7 %"}],"parameters_en":[{"name":"Receiver – fₗₘ, lower cut-off frequency","range":"1 kHz to 100 kHz","cmc":"2,4 %"},{"name":"Receiver – fᵤₘ, upper cut-off frequency","range":"1 kHz to 100 kHz","cmc":"2,4 %"},{"name":"Receiver – f₀, centre frequency","range":"1 kHz to 100 kHz","cmc":"2,5 %"},{"name":"Receiver – Δf, bandwidth","range":"1 kHz to 100 kHz","cmc":"5,7 %"}],"parameters_zh":[{"name":"接收器 – fₗₘ，下限截止频率","range":"1 kHz 至 100 kHz","cmc":"2,4 %"},{"name":"接收器 – fᵤₘ，上限截止频率","range":"1 kHz 至 100 kHz","cmc":"2,4 %"},{"name":"接收器 – f₀，中心频率","range":"1 kHz 至 100 kHz","cmc":"2,5 %"},{"name":"接收器 – Δf，带宽","range":"1 kHz 至 100 kHz","cmc":"5,7 %"}],"parameters_cs":[{"name":"Příjímač – fₗₘ, dolní mezní frekvence","range":"1 kHz až 100 kHz","cmc":"2,4 %"},{"name":"Přijímač – fᵤₘ, horní mezní frekvence","range":"1 kHz až 100 kHz","cmc":"2,4 %"},{"name":"Přijímač – f₀, střední frekvence","range":"1 kHz až 100 kHz","cmc":"2,5 %"},{"name":"Přijímač – Δf, šířka pásma","range":"1 kHz až 100 kHz","cmc":"5,7 %"}],"technique":"Generowanie sygnału wzorcowym generatorem","technique_en":"Signal generation with a standard generator","technique_zh":"用标准信号发生器产生信号","technique_cs":"Generování signálu etalonovým generátorem","techniques":["Generowanie sygnału wzorcowym generatorem"],"techniques_en":["Signal generation with a standard generator"],"techniques_zh":["用标准信号发生器产生信号"],"techniques_cs":["Generování signálu etalonovým generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nOdbiornik – fₗₘ, dolna częstotliwość graniczna od 1 kHz do 100 kHz CMC 2,4 %\nOdbiornik – fᵤₘ, górna częstotliwość graniczna od 1 kHz do 100 kHz CMC 2,4 %\nOdbiornik – f₀, częstotliwość środkowa od 1 kHz do 100 kHz CMC 2,5 %\nOdbiornik – Δf, szerokość pasma od 1 kHz do 100 kHz CMC 5,7 %\nGenerowanie sygnału wzorcowym generatorem","reference":"A 04-51/29 (ČSN EN ISO 15548-1)","norm_bases":["A 04-51/29","ČSN EN ISO 15548-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy wiroprądowe Wzorcowanie – badania właściwości i wad materiałów Generowanie sygnału wzorcowym generatorem Odbiornik – fₗₘ, dolna częstotliwość graniczna od 1 kHz do 100 kHz CMC 2,4 % Odbiornik – fᵤₘ, górna częstotliwość graniczna od 1 kHz do 100 kHz CMC 2,4 % Odbiornik – f₀, częstotliwość środkowa od 1 kHz do 100 kHz CMC 2,5 % Odbiornik – Δf, szerokość pasma od 1 kHz do 100 kHz CMC 5,7 % Vířivoproudé defektoskopy Kalibrace – zkoušky vlastností a vad materiálů Generování signálu etalonovým generátorem Příjímač – fₗₘ, dolní mezní frekvence 1 kHz až 100 kHz CMC 2,4 % Přijímač – fᵤₘ, horní mezní frekvence 1 kHz až 100 kHz CMC 2,4 % Přijímač – f₀, střední frekvence 1 kHz až 100 kHz CMC 2,5 % Přijímač – Δf, šířka pásma 1 kHz až 100 kHz CMC 5,7 % A 04-51/29 (ČSN EN ISO 15548-1) Defektoskopy wiropradowe Wzorcowanie – badania wlasciwosci i wad materialow Generowanie sygnalu wzorcowym generatorem Odbiornik – fₗₘ, dolna czestotliwosc graniczna od 1 kHz do 100 kHz CMC 2,4 % Odbiornik – fᵤₘ, gorna czestotliwosc graniczna od 1 kHz do 100 kHz CMC 2,4 % Odbiornik – f₀, czestotliwosc srodkowa od 1 kHz do 100 kHz CMC 2,5 % Odbiornik – Δf, szerokosc pasma od 1 kHz do 100 kHz CMC 5,7 % Virivoproude defektoskopy Kalibrace – zkousky vlastnosti a vad materialu Generovani signalu etalonovym generatorem Prijimac – fₗₘ, dolni mezni frekvence 1 kHz az 100 kHz CMC 2,4 % Prijimac – fᵤₘ, horni mezni frekvence 1 kHz az 100 kHz CMC 2,4 % Prijimac – f₀, stredni frekvence 1 kHz az 100 kHz CMC 2,5 % Prijimac – Δf, sirka pasma 1 kHz az 100 kHz CMC 5,7 % A 04-51/29 (CSN EN ISO 15548-1)","search_en":"Eddy current flaw detectors Calibration – testing of properties and defects of materials Signal generation with a standard generator Receiver – fₗₘ, lower cut-off frequency 1 kHz to 100 kHz CMC 2,4 % Receiver – fᵤₘ, upper cut-off frequency 1 kHz to 100 kHz CMC 2,4 % Receiver – f₀, centre frequency 1 kHz to 100 kHz CMC 2,5 % Receiver – Δf, bandwidth 1 kHz to 100 kHz CMC 5,7 % A 04-51/29 (ČSN EN ISO 15548-1)","search_zh":"涡流探伤仪 校准 – 材料性能和缺陷检测 用标准信号发生器产生信号 接收器 – fₗₘ，下限截止频率 1 kHz 至 100 kHz CMC 2,4 % 接收器 – fᵤₘ，上限截止频率 1 kHz 至 100 kHz CMC 2,4 % 接收器 – f₀，中心频率 1 kHz 至 100 kHz CMC 2,5 % 接收器 – Δf，带宽 1 kHz 至 100 kHz CMC 5,7 % A 04-51/29 (ČSN EN ISO 15548-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f7bbbde776c32070e6451275","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"7","test_object":"Defektoskopy wiroprądowe","test_object_en":"Eddy current flaw detectors","test_object_zh":"涡流探伤仪","test_object_cs":"Vířivoproudé defektoskopy","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Odbiornik – dokładność tłumika; 1 kHz do 100 kHz","range":"od 0 dB do 30 dB","cmc":"0,43 dB"}],"parameters_en":[{"name":"Receiver – attenuator accuracy; 1 kHz to 100 kHz","range":"0 dB to 30 dB","cmc":"0,43 dB"}],"parameters_zh":[{"name":"接收器 – 衰减器准确度；1 kHz 至 100 kHz","range":"0 dB 至 30 dB","cmc":"0,43 dB"}],"parameters_cs":[{"name":"Přijímač – přesnost atenuátoru; 1 kHz až 100 kHz","range":"0 dB až 30 dB","cmc":"0,43 dB"}],"technique":"Porównanie z wzorcowym tłumikiem","technique_en":"Comparison with a standard attenuator","technique_zh":"与标准衰减器比较","technique_cs":"Porovnání s etalonovým atenuátorem","techniques":["Porównanie z wzorcowym tłumikiem"],"techniques_en":["Comparison with a standard attenuator"],"techniques_zh":["与标准衰减器比较"],"techniques_cs":["Porovnání s etalonovým atenuátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nOdbiornik – dokładność tłumika; 1 kHz do 100 kHz od 0 dB do 30 dB CMC 0,43 dB\nPorównanie z wzorcowym tłumikiem","reference":"A 04-51/29 (ČSN EN ISO 15548-1)","norm_bases":["A 04-51/29","ČSN EN ISO 15548-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy wiroprądowe Wzorcowanie – badania właściwości i wad materiałów Porównanie z wzorcowym tłumikiem Odbiornik – dokładność tłumika; 1 kHz do 100 kHz od 0 dB do 30 dB CMC 0,43 dB Vířivoproudé defektoskopy Kalibrace – zkoušky vlastností a vad materiálů Porovnání s etalonovým atenuátorem Přijímač – přesnost atenuátoru; 1 kHz až 100 kHz 0 dB až 30 dB CMC 0,43 dB A 04-51/29 (ČSN EN ISO 15548-1) Defektoskopy wiropradowe Wzorcowanie – badania wlasciwosci i wad materialow Porownanie z wzorcowym tlumikiem Odbiornik – dokladnosc tlumika; 1 kHz do 100 kHz od 0 dB do 30 dB CMC 0,43 dB Virivoproude defektoskopy Kalibrace – zkousky vlastnosti a vad materialu Porovnani s etalonovym atenuatorem Prijimac – presnost atenuatoru; 1 kHz az 100 kHz 0 dB az 30 dB CMC 0,43 dB A 04-51/29 (CSN EN ISO 15548-1)","search_en":"Eddy current flaw detectors Calibration – testing of properties and defects of materials Comparison with a standard attenuator Receiver – attenuator accuracy; 1 kHz to 100 kHz 0 dB to 30 dB CMC 0,43 dB A 04-51/29 (ČSN EN ISO 15548-1)","search_zh":"涡流探伤仪 校准 – 材料性能和缺陷检测 与标准衰减器比较 接收器 – 衰减器准确度；1 kHz 至 100 kHz 0 dB 至 30 dB CMC 0,43 dB A 04-51/29 (ČSN EN ISO 15548-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9233a690757c954869613669","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"8","test_object":"Defektoskopy ultradźwiękowe cyfrowe","test_object_en":"Digital ultrasonic flaw detectors","test_object_zh":"数字超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy digitální","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Nadajnik – amplituda napięcia impulsu","range":"od 1 V do 400 V","cmc":"3,2 %"},{"name":"Nadajnik – czas narastania impulsu","range":"od 0 ns do 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Nadajnik – czas trwania impulsu","range":"od 0 ns do 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_en":[{"name":"Transmitter – pulse voltage amplitude","range":"1 V to 400 V","cmc":"3,2 %"},{"name":"Transmitter – pulse rise time","range":"0 ns to 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Transmitter – pulse duration","range":"0 ns to 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_zh":[{"name":"发射器 – 脉冲电压幅度","range":"1 V 至 400 V","cmc":"3,2 %"},{"name":"发射器 – 脉冲上升时间","range":"0 ns 至 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"发射器 – 脉冲持续时间","range":"0 ns 至 500 ns","cmc":"2,7 % + 2,4 ns"}],"parameters_cs":[{"name":"Vysílač – Amplituda napětí impulzu","range":"1 V až 400 V","cmc":"3,2 %"},{"name":"Vysílač – Doba náběhu impulzu","range":"0 ns až 500 ns","cmc":"2,7 % + 2,4 ns"},{"name":"Vysílač – Doba trvání impulzu","range":"0 ns až 500 ns","cmc":"2,7 % + 2,4 ns"}],"technique":"Bezpośredni pomiar sygnału wzorcowym oscyloskopem","technique_en":"Direct measurement of the signal with a standard oscilloscope","technique_zh":"用标准示波器直接测量信号","technique_cs":"Přímé měření signálu etalonovým osciloskopem","techniques":["Bezpośredni pomiar sygnału wzorcowym oscyloskopem"],"techniques_en":["Direct measurement of the signal with a standard oscilloscope"],"techniques_zh":["用标准示波器直接测量信号"],"techniques_cs":["Přímé měření signálu etalonovým osciloskopem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nNadajnik – amplituda napięcia impulsu od 1 V do 400 V CMC 3,2 %\nNadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns\nNadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns\nBezpośredni pomiar sygnału wzorcowym oscyloskopem","reference":"A 04-55/21 (ČSN EN ISO 22232-1)","norm_bases":["A 04-55/21","ČSN EN ISO 22232-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe cyfrowe Wzorcowanie – badania właściwości i wad materiałów Bezpośredni pomiar sygnału wzorcowym oscyloskopem Nadajnik – amplituda napięcia impulsu od 1 V do 400 V CMC 3,2 % Nadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Nadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Ultrazvukové defektoskopy digitální Kalibrace – zkoušky vlastností a vad materiálů Přímé měření signálu etalonovým osciloskopem Vysílač – Amplituda napětí impulzu 1 V až 400 V CMC 3,2 % Vysílač – Doba náběhu impulzu 0 ns až 500 ns CMC 2,7 % + 2,4 ns Vysílač – Doba trvání impulzu 0 ns až 500 ns CMC 2,7 % + 2,4 ns A 04-55/21 (ČSN EN ISO 22232-1) Defektoskopy ultradzwiekowe cyfrowe Wzorcowanie – badania wlasciwosci i wad materialow Bezposredni pomiar sygnalu wzorcowym oscyloskopem Nadajnik – amplituda napiecia impulsu od 1 V do 400 V CMC 3,2 % Nadajnik – czas narastania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Nadajnik – czas trwania impulsu od 0 ns do 500 ns CMC 2,7 % + 2,4 ns Ultrazvukove defektoskopy digitalni Kalibrace – zkousky vlastnosti a vad materialu Prime mereni signalu etalonovym osciloskopem Vysilac – Amplituda napeti impulzu 1 V az 400 V CMC 3,2 % Vysilac – Doba nabehu impulzu 0 ns az 500 ns CMC 2,7 % + 2,4 ns Vysilac – Doba trvani impulzu 0 ns az 500 ns CMC 2,7 % + 2,4 ns A 04-55/21 (CSN EN ISO 22232-1)","search_en":"Digital ultrasonic flaw detectors Calibration – testing of properties and defects of materials Direct measurement of the signal with a standard oscilloscope Transmitter – pulse voltage amplitude 1 V to 400 V CMC 3,2 % Transmitter – pulse rise time 0 ns to 500 ns CMC 2,7 % + 2,4 ns Transmitter – pulse duration 0 ns to 500 ns CMC 2,7 % + 2,4 ns A 04-55/21 (ČSN EN ISO 22232-1)","search_zh":"数字超声波探伤仪 校准 – 材料性能和缺陷检测 用标准示波器直接测量信号 发射器 – 脉冲电压幅度 1 V 至 400 V CMC 3,2 % 发射器 – 脉冲上升时间 0 ns 至 500 ns CMC 2,7 % + 2,4 ns 发射器 – 脉冲持续时间 0 ns 至 500 ns CMC 2,7 % + 2,4 ns A 04-55/21 (ČSN EN ISO 22232-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"48970398034e3a9177c1bf50","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"8","test_object":"Defektoskopy ultradźwiękowe cyfrowe","test_object_en":"Digital ultrasonic flaw detectors","test_object_zh":"数字超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy digitální","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Odbiornik – fₗₘ, dolna częstotliwość graniczna","range":"od 0,1 MHz do 25 MHz","cmc":"3,3 %"},{"name":"Odbiornik – fᵤₘ, górna częstotliwość graniczna","range":"od 0,1 MHz do 25 MHz","cmc":"3,3 %"},{"name":"Odbiornik – f₀, częstotliwość środkowa","range":"od 0,1 MHz do 25 MHz","cmc":"3,5 %"},{"name":"Odbiornik – Δf, szerokość pasma","range":"od 0,1 MHz do 25 MHz","cmc":"4,7 %"},{"name":"Odchyłka podstawy czasu","range":"od 0,5 µs do 2000 µs","cmc":"1,1 % + 0,05 µs"}],"parameters_en":[{"name":"Receiver – fₗₘ, lower cut-off frequency","range":"0,1 MHz to 25 MHz","cmc":"3,3 %"},{"name":"Receiver – fᵤₘ, upper cut-off frequency","range":"0,1 MHz to 25 MHz","cmc":"3,3 %"},{"name":"Receiver – f₀, centre frequency","range":"0,1 MHz to 25 MHz","cmc":"3,5 %"},{"name":"Receiver – Δf, bandwidth","range":"0,1 MHz to 25 MHz","cmc":"4,7 %"},{"name":"Time base deviation","range":"0,5 µs to 2000 µs","cmc":"1,1 % + 0,05 µs"}],"parameters_zh":[{"name":"接收器 – fₗₘ，下限截止频率","range":"0,1 MHz 至 25 MHz","cmc":"3,3 %"},{"name":"接收器 – fᵤₘ，上限截止频率","range":"0,1 MHz 至 25 MHz","cmc":"3,3 %"},{"name":"接收器 – f₀，中心频率","range":"0,1 MHz 至 25 MHz","cmc":"3,5 %"},{"name":"接收器 – Δf，带宽","range":"0,1 MHz 至 25 MHz","cmc":"4,7 %"},{"name":"时基偏差","range":"0,5 µs 至 2000 µs","cmc":"1,1 % + 0,05 µs"}],"parameters_cs":[{"name":"Přijímač – fₗₘ, dolní mezní frekvence","range":"0,1 MHz až 25 MHz","cmc":"3,3 %"},{"name":"Přijímač – fᵤₘ, horní mezní frekvence","range":"0,1 MHz až 25 MHz","cmc":"3,3 %"},{"name":"Přijímač – f₀, střední frekvence","range":"0,1 MHz až 25 MHz","cmc":"3,5 %"},{"name":"Přijímač – Δf, šířka pásma","range":"0,1 MHz až 25 MHz","cmc":"4,7 %"},{"name":"Odchylka časové základny","range":"0,5 µs až 2000 µs","cmc":"1,1 % + 0,05 µs"}],"technique":"Generowanie sygnału wzorcowym generatorem","technique_en":"Signal generation with a standard generator","technique_zh":"用标准信号发生器产生信号","technique_cs":"Generování signálu etalonovým generátorem","techniques":["Generowanie sygnału wzorcowym generatorem"],"techniques_en":["Signal generation with a standard generator"],"techniques_zh":["用标准信号发生器产生信号"],"techniques_cs":["Generování signálu etalonovým generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nOdbiornik – fₗₘ, dolna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 %\nOdbiornik – fᵤₘ, górna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 %\nOdbiornik – f₀, częstotliwość środkowa od 0,1 MHz do 25 MHz CMC 3,5 %\nOdbiornik – Δf, szerokość pasma od 0,1 MHz do 25 MHz CMC 4,7 %\nOdchyłka podstawy czasu od 0,5 µs do 2000 µs CMC 1,1 % + 0,05 µs\nGenerowanie sygnału wzorcowym generatorem","reference":"A 04-55/21 (ČSN EN ISO 22232-1)","norm_bases":["A 04-55/21","ČSN EN ISO 22232-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe cyfrowe Wzorcowanie – badania właściwości i wad materiałów Generowanie sygnału wzorcowym generatorem Odbiornik – fₗₘ, dolna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – fᵤₘ, górna częstotliwość graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – f₀, częstotliwość środkowa od 0,1 MHz do 25 MHz CMC 3,5 % Odbiornik – Δf, szerokość pasma od 0,1 MHz do 25 MHz CMC 4,7 % Odchyłka podstawy czasu od 0,5 µs do 2000 µs CMC 1,1 % + 0,05 µs Ultrazvukové defektoskopy digitální Kalibrace – zkoušky vlastností a vad materiálů Generování signálu etalonovým generátorem Přijímač – fₗₘ, dolní mezní frekvence 0,1 MHz až 25 MHz CMC 3,3 % Přijímač – fᵤₘ, horní mezní frekvence 0,1 MHz až 25 MHz CMC 3,3 % Přijímač – f₀, střední frekvence 0,1 MHz až 25 MHz CMC 3,5 % Přijímač – Δf, šířka pásma 0,1 MHz až 25 MHz CMC 4,7 % Odchylka časové základny 0,5 µs až 2000 µs CMC 1,1 % + 0,05 µs A 04-55/21 (ČSN EN ISO 22232-1) Defektoskopy ultradzwiekowe cyfrowe Wzorcowanie – badania wlasciwosci i wad materialow Generowanie sygnalu wzorcowym generatorem Odbiornik – fₗₘ, dolna czestotliwosc graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – fᵤₘ, gorna czestotliwosc graniczna od 0,1 MHz do 25 MHz CMC 3,3 % Odbiornik – f₀, czestotliwosc srodkowa od 0,1 MHz do 25 MHz CMC 3,5 % Odbiornik – Δf, szerokosc pasma od 0,1 MHz do 25 MHz CMC 4,7 % Odchylka podstawy czasu od 0,5 µs do 2000 µs CMC 1,1 % + 0,05 µs Ultrazvukove defektoskopy digitalni Kalibrace – zkousky vlastnosti a vad materialu Generovani signalu etalonovym generatorem Prijimac – fₗₘ, dolni mezni frekvence 0,1 MHz az 25 MHz CMC 3,3 % Prijimac – fᵤₘ, horni mezni frekvence 0,1 MHz az 25 MHz CMC 3,3 % Prijimac – f₀, stredni frekvence 0,1 MHz az 25 MHz CMC 3,5 % Prijimac – Δf, sirka pasma 0,1 MHz az 25 MHz CMC 4,7 % Odchylka casove zakladny 0,5 µs az 2000 µs CMC 1,1 % + 0,05 µs A 04-55/21 (CSN EN ISO 22232-1)","search_en":"Digital ultrasonic flaw detectors Calibration – testing of properties and defects of materials Signal generation with a standard generator Receiver – fₗₘ, lower cut-off frequency 0,1 MHz to 25 MHz CMC 3,3 % Receiver – fᵤₘ, upper cut-off frequency 0,1 MHz to 25 MHz CMC 3,3 % Receiver – f₀, centre frequency 0,1 MHz to 25 MHz CMC 3,5 % Receiver – Δf, bandwidth 0,1 MHz to 25 MHz CMC 4,7 % Time base deviation 0,5 µs to 2000 µs CMC 1,1 % + 0,05 µs A 04-55/21 (ČSN EN ISO 22232-1)","search_zh":"数字超声波探伤仪 校准 – 材料性能和缺陷检测 用标准信号发生器产生信号 接收器 – fₗₘ，下限截止频率 0,1 MHz 至 25 MHz CMC 3,3 % 接收器 – fᵤₘ，上限截止频率 0,1 MHz 至 25 MHz CMC 3,3 % 接收器 – f₀，中心频率 0,1 MHz 至 25 MHz CMC 3,5 % 接收器 – Δf，带宽 0,1 MHz 至 25 MHz CMC 4,7 % 时基偏差 0,5 µs 至 2000 µs CMC 1,1 % + 0,05 µs A 04-55/21 (ČSN EN ISO 22232-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4e9b06db40adf0b03b9040ba","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"8","test_object":"Defektoskopy ultradźwiękowe cyfrowe","test_object_en":"Digital ultrasonic flaw detectors","test_object_zh":"数字超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy digitální","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Odbiornik – poziom szumów","range":"od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"parameters_en":[{"name":"Receiver – noise level","range":"10⁻¹² V/√Hz to 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"parameters_zh":[{"name":"接收器 – 噪声电平","range":"10⁻¹² V/√Hz 至 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"parameters_cs":[{"name":"Přijímač – úroveň šumu","range":"10⁻¹² V/√Hz až 10⁻⁶ V/√Hz","cmc":"2,7·10⁻⁹ V/√Hz"}],"technique":"Bezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem","technique_en":"Direct measurement of the signal with a standard oscilloscope, comparison with a standard attenuator","technique_zh":"用标准示波器直接测量信号，与标准衰减器比较","technique_cs":"Přímé měření signálu etalonovým osciloskopem, porovnání s etalonovým atenuátorem","techniques":["Bezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem"],"techniques_en":["Direct measurement of the signal with a standard oscilloscope, comparison with a standard attenuator"],"techniques_zh":["用标准示波器直接测量信号，与标准衰减器比较"],"techniques_cs":["Přímé měření signálu etalonovým osciloskopem, porovnání s etalonovým atenuátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nOdbiornik – poziom szumów od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz\nBezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem","reference":"A 04-55/21 (ČSN EN ISO 22232-1)","norm_bases":["A 04-55/21","ČSN EN ISO 22232-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe cyfrowe Wzorcowanie – badania właściwości i wad materiałów Bezpośredni pomiar sygnału wzorcowym oscyloskopem, porównanie z wzorcowym tłumikiem Odbiornik – poziom szumów od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz Ultrazvukové defektoskopy digitální Kalibrace – zkoušky vlastností a vad materiálů Přímé měření signálu etalonovým osciloskopem, porovnání s etalonovým atenuátorem Přijímač – úroveň šumu 10⁻¹² V/√Hz až 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/21 (ČSN EN ISO 22232-1) Defektoskopy ultradzwiekowe cyfrowe Wzorcowanie – badania wlasciwosci i wad materialow Bezposredni pomiar sygnalu wzorcowym oscyloskopem, porownanie z wzorcowym tlumikiem Odbiornik – poziom szumow od 10⁻¹² V/√Hz do 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz Ultrazvukove defektoskopy digitalni Kalibrace – zkousky vlastnosti a vad materialu Prime mereni signalu etalonovym osciloskopem, porovnani s etalonovym atenuatorem Prijimac – uroven sumu 10⁻¹² V/√Hz az 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/21 (CSN EN ISO 22232-1)","search_en":"Digital ultrasonic flaw detectors Calibration – testing of properties and defects of materials Direct measurement of the signal with a standard oscilloscope, comparison with a standard attenuator Receiver – noise level 10⁻¹² V/√Hz to 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/21 (ČSN EN ISO 22232-1)","search_zh":"数字超声波探伤仪 校准 – 材料性能和缺陷检测 用标准示波器直接测量信号，与标准衰减器比较 接收器 – 噪声电平 10⁻¹² V/√Hz 至 10⁻⁶ V/√Hz CMC 2,7·10⁻⁹ V/√Hz A 04-55/21 (ČSN EN ISO 22232-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c62165f0eb0da8fab175448a","lab_id":"6ade8b3aff0682476170811f","country":"CZ","accr_number":"2355","accr_body":"ČIA","row_label":"8","test_object":"Defektoskopy ultradźwiękowe cyfrowe","test_object_en":"Digital ultrasonic flaw detectors","test_object_zh":"数字超声波探伤仪","test_object_cs":"Ultrazvukové defektoskopy digitální","methodology":"Wzorcowanie – badania właściwości i wad materiałów","methodology_en":"Calibration – testing of properties and defects of materials","methodology_zh":"校准 – 材料性能和缺陷检测","methodology_cs":"Kalibrace – zkoušky vlastností a vad materiálů","parameters":[{"name":"Odbiornik – liniowość wzmocnienia","range":"od 0 dB do 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"Odbiornik – liniowość pionowa zobrazowania","range":"od 0 dB do 70 dB","cmc":"2,8 % + 0,2 dB"}],"parameters_en":[{"name":"Receiver – gain linearity","range":"0 dB to 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"Receiver – vertical display linearity","range":"0 dB to 70 dB","cmc":"2,8 % + 0,2 dB"}],"parameters_zh":[{"name":"接收器 – 增益线性","range":"0 dB 至 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"接收器 – 显示垂直线性","range":"0 dB 至 70 dB","cmc":"2,8 % + 0,2 dB"}],"parameters_cs":[{"name":"Přijímač – linearita zesílení","range":"0 dB až 70 dB","cmc":"2,8 % + 0,2 dB"},{"name":"Přijímač – vertikální linearita zobrazení","range":"0 dB až 70 dB","cmc":"2,8 % + 0,2 dB"}],"technique":"Porównanie z wzorcowym tłumikiem","technique_en":"Comparison with a standard attenuator","technique_zh":"与标准衰减器比较","technique_cs":"Porovnání s etalonovým atenuátorem","techniques":["Porównanie z wzorcowym tłumikiem"],"techniques_en":["Comparison with a standard attenuator"],"techniques_zh":["与标准衰减器比较"],"techniques_cs":["Porovnání s etalonovým atenuátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – badania właściwości i wad materiałów\nZakres:\nOdbiornik – liniowość wzmocnienia od 0 dB do 70 dB CMC 2,8 % + 0,2 dB\nOdbiornik – liniowość pionowa zobrazowania od 0 dB do 70 dB CMC 2,8 % + 0,2 dB\nPorównanie z wzorcowym tłumikiem","reference":"A 04-55/21 (ČSN EN ISO 22232-1)","norm_bases":["A 04-55/21","ČSN EN ISO 22232-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: badania właściwości i wad materiałów","regulatory_area_en":"CMC for the field of measured quantity: Testing of properties and defects of materials","regulatory_area_zh":"被测量领域的CMC：材料性能和缺陷检测","regulatory_area_cs":"CMC pro obor měřené veličiny: Zkoušky vlastností a vad materiálů","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Defektoskopy ultradźwiękowe cyfrowe Wzorcowanie – badania właściwości i wad materiałów Porównanie z wzorcowym tłumikiem Odbiornik – liniowość wzmocnienia od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Odbiornik – liniowość pionowa zobrazowania od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Ultrazvukové defektoskopy digitální Kalibrace – zkoušky vlastností a vad materiálů Porovnání s etalonovým atenuátorem Přijímač – linearita zesílení 0 dB až 70 dB CMC 2,8 % + 0,2 dB Přijímač – vertikální linearita zobrazení 0 dB až 70 dB CMC 2,8 % + 0,2 dB A 04-55/21 (ČSN EN ISO 22232-1) Defektoskopy ultradzwiekowe cyfrowe Wzorcowanie – badania wlasciwosci i wad materialow Porownanie z wzorcowym tlumikiem Odbiornik – liniowosc wzmocnienia od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Odbiornik – liniowosc pionowa zobrazowania od 0 dB do 70 dB CMC 2,8 % + 0,2 dB Ultrazvukove defektoskopy digitalni Kalibrace – zkousky vlastnosti a vad materialu Porovnani s etalonovym atenuatorem Prijimac – linearita zesileni 0 dB az 70 dB CMC 2,8 % + 0,2 dB Prijimac – vertikalni linearita zobrazeni 0 dB az 70 dB CMC 2,8 % + 0,2 dB A 04-55/21 (CSN EN ISO 22232-1)","search_en":"Digital ultrasonic flaw detectors Calibration – testing of properties and defects of materials Comparison with a standard attenuator Receiver – gain linearity 0 dB to 70 dB CMC 2,8 % + 0,2 dB Receiver – vertical display linearity 0 dB to 70 dB CMC 2,8 % + 0,2 dB A 04-55/21 (ČSN EN ISO 22232-1)","search_zh":"数字超声波探伤仪 校准 – 材料性能和缺陷检测 与标准衰减器比较 接收器 – 增益线性 0 dB 至 70 dB CMC 2,8 % + 0,2 dB 接收器 – 显示垂直线性 0 dB 至 70 dB CMC 2,8 % + 0,2 dB A 04-55/21 (ČSN EN ISO 22232-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}