{"lab":{"_id":"6ade8b37ff0682476170811c","accr_number":"2340","country":"CZ","accr_body":"ČIA","address":"Hlavní 130, Řež, 250 68 Husinec","categories":["metrology"],"city":"Husinec","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.3585796,50.1775159]},"map_coord":[50.1775159,14.3585796],"map_geo":"cai-mapa","methods_count":11,"name":"ÚJV Řež, a. s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: ciśnienie i temperatura, w zakresie określonym w załączniku do świadectwa.","search_text":"újv řež, a. s. hlavní 130, řež, 250 68 husinec 2340","source_page_url":"https://www.cai.cz/?subjekt=2340-ujv-rez-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"12-03-2031","website":"www.ujv.cz","certificate_date":"12.03.2026","certificate_no":"121/2026","certificate_replaces":"111/2024 z 06.03.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: ciśnienie i temperatura, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of pressure and temperature, to the extent specified in the appendix to this Certificate.","zh":"压力和温度领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech tlak a teplota, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"f7c2f6abc791dca95495197411d4ade27f03552a86b6ff95b458a2d443661b6f","source_pdf_url":"https://www.cai.cz/OA/pdf/121_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"5ec79306764d41a1bf6975af","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital pressure gauges, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřící řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"medium: gaz; nadciśnienie","range":"od -90 kPa do -1 kPa","cmc":"100 Pa"},{"name":"medium: gaz; nadciśnienie","range":"od -1 kPa do 1 kPa","cmc":"2,5 Pa"},{"name":"medium: gaz; nadciśnienie","range":"od 1 kPa do 6,9 kPa","cmc":"21 Pa"},{"name":"medium: gaz; nadciśnienie","range":"od 6,9 kPa do 200 kPa","cmc":"0,04 % + 30 Pa"},{"name":"medium: gaz; nadciśnienie","range":"od 0,2 MPa do 2,0 MPa","cmc":"1,1 kPa"},{"name":"medium: gaz; nadciśnienie","range":"od 2,0 MPa do 4 MPa","cmc":"6,9 kPa"}],"parameters_en":[{"name":"medium: gas; gauge pressure","range":"-90 kPa to -1 kPa","cmc":"100 Pa"},{"name":"medium: gas; gauge pressure","range":"-1 kPa to 1 kPa","cmc":"2,5 Pa"},{"name":"medium: gas; gauge pressure","range":"1 kPa to 6,9 kPa","cmc":"21 Pa"},{"name":"medium: gas; gauge pressure","range":"6,9 kPa to 200 kPa","cmc":"0,04 % + 30 Pa"},{"name":"medium: gas; gauge pressure","range":"0,2 MPa to 2,0 MPa","cmc":"1,1 kPa"},{"name":"medium: gas; gauge pressure","range":"2,0 MPa to 4 MPa","cmc":"6,9 kPa"}],"parameters_zh":[{"name":"介质：气体；表压","range":"-90 kPa 至 -1 kPa","cmc":"100 Pa"},{"name":"介质：气体；表压","range":"-1 kPa 至 1 kPa","cmc":"2,5 Pa"},{"name":"介质：气体；表压","range":"1 kPa 至 6,9 kPa","cmc":"21 Pa"},{"name":"介质：气体；表压","range":"6,9 kPa 至 200 kPa","cmc":"0,04 % + 30 Pa"},{"name":"介质：气体；表压","range":"0,2 MPa 至 2,0 MPa","cmc":"1,1 kPa"},{"name":"介质：气体；表压","range":"2,0 MPa 至 4 MPa","cmc":"6,9 kPa"}],"parameters_cs":[{"name":"Médium plyn; Přetlak","range":"-90 kPa až -1 kPa","cmc":"100 Pa"},{"name":"Médium plyn; Přetlak","range":"-1 kPa až 1 kPa","cmc":"2,5 Pa"},{"name":"Médium plyn; Přetlak","range":"1 kPa až 6,9 kPa","cmc":"21 Pa"},{"name":"Médium plyn; Přetlak","range":"6,9 kPa až 200 kPa","cmc":"0,04 % + 30 Pa"},{"name":"Médium plyn; Přetlak","range":"0,2 MPa až 2,0 MPa","cmc":"1,1 kPa"},{"name":"Médium plyn; Přetlak","range":"2,0 MPa až 4 MPa","cmc":"6,9 kPa"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým číslicovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nmedium: gaz; nadciśnienie od -90 kPa do -1 kPa CMC 100 Pa\nmedium: gaz; nadciśnienie od -1 kPa do 1 kPa CMC 2,5 Pa\nmedium: gaz; nadciśnienie od 1 kPa do 6,9 kPa CMC 21 Pa\nmedium: gaz; nadciśnienie od 6,9 kPa do 200 kPa CMC 0,04 % + 30 Pa\nmedium: gaz; nadciśnienie od 0,2 MPa do 2,0 MPa CMC 1,1 kPa\nmedium: gaz; nadciśnienie od 2,0 MPa do 4 MPa CMC 6,9 kPa\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"PP 2306 086, PP 2306 088","norm_bases":["PP 2306 086","PP 2306 088"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":"W przypadku przyrządów do pomiaru ciśnienia bezwzględnego + niepewność ciśnienia barometrycznego ± 50 Pa.","note_en":"For absolute pressure instruments + uncertainty of barometric pressure ± 50 Pa.","note_zh":"对于绝对压力测量仪器，另加大气压力不确定度 ± 50 Pa。","note_cs":"V případě měřidel absolutního tlaku + nejistota barometrického tlaku ± 50 Pa.","search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym medium: gaz; nadciśnienie od -90 kPa do -1 kPa CMC 100 Pa medium: gaz; nadciśnienie od -1 kPa do 1 kPa CMC 2,5 Pa medium: gaz; nadciśnienie od 1 kPa do 6,9 kPa CMC 21 Pa medium: gaz; nadciśnienie od 6,9 kPa do 200 kPa CMC 0,04 % + 30 Pa medium: gaz; nadciśnienie od 0,2 MPa do 2,0 MPa CMC 1,1 kPa medium: gaz; nadciśnienie od 2,0 MPa do 4 MPa CMC 6,9 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřící řetězce tlaku Kalibrace – tlak Porovnání s etalonovým číslicovým tlakoměrem Médium plyn; Přetlak -90 kPa až -1 kPa CMC 100 Pa Médium plyn; Přetlak -1 kPa až 1 kPa CMC 2,5 Pa Médium plyn; Přetlak 1 kPa až 6,9 kPa CMC 21 Pa Médium plyn; Přetlak 6,9 kPa až 200 kPa CMC 0,04 % + 30 Pa Médium plyn; Přetlak 0,2 MPa až 2,0 MPa CMC 1,1 kPa Médium plyn; Přetlak 2,0 MPa až 4 MPa CMC 6,9 kPa PP 2306 086, PP 2306 088 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym medium: gaz; nadcisnienie od -90 kPa do -1 kPa CMC 100 Pa medium: gaz; nadcisnienie od -1 kPa do 1 kPa CMC 2,5 Pa medium: gaz; nadcisnienie od 1 kPa do 6,9 kPa CMC 21 Pa medium: gaz; nadcisnienie od 6,9 kPa do 200 kPa CMC 0,04 % + 30 Pa medium: gaz; nadcisnienie od 0,2 MPa do 2,0 MPa CMC 1,1 kPa medium: gaz; nadcisnienie od 2,0 MPa do 4 MPa CMC 6,9 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym cislicovym tlakomerem Medium plyn; Pretlak -90 kPa az -1 kPa CMC 100 Pa Medium plyn; Pretlak -1 kPa az 1 kPa CMC 2,5 Pa Medium plyn; Pretlak 1 kPa az 6,9 kPa CMC 21 Pa Medium plyn; Pretlak 6,9 kPa az 200 kPa CMC 0,04 % + 30 Pa Medium plyn; Pretlak 0,2 MPa az 2,0 MPa CMC 1,1 kPa Medium plyn; Pretlak 2,0 MPa az 4 MPa CMC 6,9 kPa PP 2306 086, PP 2306 088","search_en":"Deformation and digital pressure gauges, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a standard digital pressure gauge medium: gas; gauge pressure -90 kPa to -1 kPa CMC 100 Pa medium: gas; gauge pressure -1 kPa to 1 kPa CMC 2,5 Pa medium: gas; gauge pressure 1 kPa to 6,9 kPa CMC 21 Pa medium: gas; gauge pressure 6,9 kPa to 200 kPa CMC 0,04 % + 30 Pa medium: gas; gauge pressure 0,2 MPa to 2,0 MPa CMC 1,1 kPa medium: gas; gauge pressure 2,0 MPa to 4 MPa CMC 6,9 kPa PP 2306 086, PP 2306 088","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与标准数字压力表比较 介质：气体；表压 -90 kPa 至 -1 kPa CMC 100 Pa 介质：气体；表压 -1 kPa 至 1 kPa CMC 2,5 Pa 介质：气体；表压 1 kPa 至 6,9 kPa CMC 21 Pa 介质：气体；表压 6,9 kPa 至 200 kPa CMC 0,04 % + 30 Pa 介质：气体；表压 0,2 MPa 至 2,0 MPa CMC 1,1 kPa 介质：气体；表压 2,0 MPa 至 4 MPa CMC 6,9 kPa PP 2306 086, PP 2306 088","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"86305eda24af614bc9701cc7","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"2","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia","test_object_en":"Deformation and digital pressure gauges, pressure transducers and pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器和压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku a měřící řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"medium: ciecz; nadciśnienie","range":"od 0 MPa do 13,8 MPa","cmc":"6,9 kPa"},{"name":"medium: ciecz; nadciśnienie","range":"od 13,8 MPa do 70 MPa","cmc":"0,04 % + 7 kPa"}],"parameters_en":[{"name":"medium: liquid; gauge pressure","range":"0 MPa to 13,8 MPa","cmc":"6,9 kPa"},{"name":"medium: liquid; gauge pressure","range":"13,8 MPa to 70 MPa","cmc":"0,04 % + 7 kPa"}],"parameters_zh":[{"name":"介质：液体；表压","range":"0 MPa 至 13,8 MPa","cmc":"6,9 kPa"},{"name":"介质：液体；表压","range":"13,8 MPa 至 70 MPa","cmc":"0,04 % + 7 kPa"}],"parameters_cs":[{"name":"Médium kapalina; Přetlak","range":"0 MPa až 13,8 MPa","cmc":"6,9 kPa"},{"name":"Médium kapalina; Přetlak","range":"13,8 MPa až 70 MPa","cmc":"0,04 % + 7 kPa"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým číslicovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\nmedium: ciecz; nadciśnienie od 0 MPa do 13,8 MPa CMC 6,9 kPa\nmedium: ciecz; nadciśnienie od 13,8 MPa do 70 MPa CMC 0,04 % + 7 kPa\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"PP 2306 086, PP 2306 088","norm_bases":["PP 2306 086","PP 2306 088"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":"W przypadku przyrządów do pomiaru ciśnienia bezwzględnego + niepewność ciśnienia barometrycznego ± 50 Pa.","note_en":"For absolute pressure instruments + uncertainty of barometric pressure ± 50 Pa.","note_zh":"对于绝对压力测量仪器，另加大气压力不确定度 ± 50 Pa。","note_cs":"V případě měřidel absolutního tlaku + nejistota barometrického tlaku ± 50 Pa.","search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia i tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym medium: ciecz; nadciśnienie od 0 MPa do 13,8 MPa CMC 6,9 kPa medium: ciecz; nadciśnienie od 13,8 MPa do 70 MPa CMC 0,04 % + 7 kPa Deformační a číslicové tlakoměry, převodníky tlaku a měřící řetězce tlaku Kalibrace – tlak Porovnání s etalonovým číslicovým tlakoměrem Médium kapalina; Přetlak 0 MPa až 13,8 MPa CMC 6,9 kPa Médium kapalina; Přetlak 13,8 MPa až 70 MPa CMC 0,04 % + 7 kPa PP 2306 086, PP 2306 088 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia i tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym medium: ciecz; nadcisnienie od 0 MPa do 13,8 MPa CMC 6,9 kPa medium: ciecz; nadcisnienie od 13,8 MPa do 70 MPa CMC 0,04 % + 7 kPa Deformacni a cislicove tlakomery, prevodniky tlaku a merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym cislicovym tlakomerem Medium kapalina; Pretlak 0 MPa az 13,8 MPa CMC 6,9 kPa Medium kapalina; Pretlak 13,8 MPa az 70 MPa CMC 0,04 % + 7 kPa PP 2306 086, PP 2306 088","search_en":"Deformation and digital pressure gauges, pressure transducers and pressure measuring chains Calibration – pressure Comparison with a standard digital pressure gauge medium: liquid; gauge pressure 0 MPa to 13,8 MPa CMC 6,9 kPa medium: liquid; gauge pressure 13,8 MPa to 70 MPa CMC 0,04 % + 7 kPa PP 2306 086, PP 2306 088","search_zh":"弹性式和数字式压力表、压力变送器和压力测量链 校准 – 压力 与标准数字压力表比较 介质：液体；表压 0 MPa 至 13,8 MPa CMC 6,9 kPa 介质：液体；表压 13,8 MPa 至 70 MPa CMC 0,04 % + 7 kPa PP 2306 086, PP 2306 088","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a59b2dc60f24e49e89ca6618","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"3","test_object":"Ciśnienie barometryczne","test_object_en":"Barometric pressure","test_object_zh":"大气压力","test_object_cs":"Barometrický tlak","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"","range":"od 70 kPa do 110 kPa","cmc":"50 Pa"}],"parameters_en":[{"name":"","range":"70 kPa to 110 kPa","cmc":"50 Pa"}],"parameters_zh":[{"name":"","range":"70 kPa 至 110 kPa","cmc":"50 Pa"}],"parameters_cs":[{"name":"","range":"70 kPa až 110 kPa","cmc":"50 Pa"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital pressure gauge","technique_zh":"与标准数字压力表比较","technique_cs":"Porovnání s etalonovým číslicovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital pressure gauge"],"techniques_zh":["与标准数字压力表比较"],"techniques_cs":["Porovnání s etalonovým číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nod 70 kPa do 110 kPa CMC 50 Pa\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"PP 2306 088","norm_bases":["PP 2306 088"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnienie barometryczne Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym od 70 kPa do 110 kPa CMC 50 Pa Barometrický tlak Kalibrace – tlak Porovnání s etalonovým číslicovým tlakoměrem 70 kPa až 110 kPa CMC 50 Pa PP 2306 088 Cisnienie barometryczne Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym od 70 kPa do 110 kPa CMC 50 Pa Barometricky tlak Kalibrace – tlak Porovnani s etalonovym cislicovym tlakomerem 70 kPa az 110 kPa CMC 50 Pa PP 2306 088","search_en":"Barometric pressure Calibration – pressure Comparison with a standard digital pressure gauge 70 kPa to 110 kPa CMC 50 Pa PP 2306 088","search_zh":"大气压力 校准 – 压力 与标准数字压力表比较 70 kPa 至 110 kPa CMC 50 Pa PP 2306 088","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9873e45d1fdb9fec8a6658d4","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"1","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 0 °C","cmc":"0,06 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"0,08 °C"},{"name":"","range":"od 50 °C do 140 °C","cmc":"0,11 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"0,08 °C"},{"name":"","range":"50 °C to 140 °C","cmc":"0,11 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"0,08 °C"},{"name":"","range":"50 °C 至 140 °C","cmc":"0,11 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"0,08 °C"},{"name":"","range":"50 °C až 140 °C","cmc":"0,11 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w mikrołaźni","technique_en":"Comparison with a standard resistance thermometer in a micro-bath","technique_zh":"在微型槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v mikrolázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w mikrołaźni"],"techniques_en":["Comparison with a standard resistance thermometer in a micro-bath"],"techniques_zh":["在微型槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v mikrolázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 0 °C CMC 0,06 °C\nod 0 °C do 50 °C CMC 0,08 °C\nod 50 °C do 140 °C CMC 0,11 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w mikrołaźni","reference":"PP 2306 083","norm_bases":["PP 2306 083"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w mikrołaźni od -30 °C do 0 °C CMC 0,06 °C od 0 °C do 50 °C CMC 0,08 °C od 50 °C do 140 °C CMC 0,11 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v mikrolázni -30 °C až 0 °C CMC 0,06 °C 0 °C až 50 °C CMC 0,08 °C 50 °C až 140 °C CMC 0,11 °C PP 2306 083 Termometry szklane Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w mikrolazni od -30 °C do 0 °C CMC 0,06 °C od 0 °C do 50 °C CMC 0,08 °C od 50 °C do 140 °C CMC 0,11 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v mikrolazni -30 °C az 0 °C CMC 0,06 °C 0 °C az 50 °C CMC 0,08 °C 50 °C az 140 °C CMC 0,11 °C PP 2306 083","search_en":"Glass thermometers Calibration – temperature Comparison with a standard resistance thermometer in a micro-bath -30 °C to 0 °C CMC 0,06 °C 0 °C to 50 °C CMC 0,08 °C 50 °C to 140 °C CMC 0,11 °C PP 2306 083","search_zh":"玻璃温度计 校准 – 温度 在微型槽中与标准电阻温度计比较 -30 °C 至 0 °C CMC 0,06 °C 0 °C 至 50 °C CMC 0,08 °C 50 °C 至 140 °C CMC 0,11 °C PP 2306 083","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"33c8e71e86d0950cae854b76","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"2","test_object":"Termopary","test_object_en":"Thermocouples","test_object_zh":"热电偶","test_object_cs":"Termoelektrické články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,4 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,4 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,4 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,4 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie","technique_en":"Comparison with a standard resistance thermometer immersed in liquid nitrogen","technique_zh":"与浸入液氮中的标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem ponořeným v kapalném dusíku","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie"],"techniques_en":["Comparison with a standard resistance thermometer immersed in liquid nitrogen"],"techniques_zh":["与浸入液氮中的标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem ponořeným v kapalném dusíku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n-196 °C CMC 0,4 °C\nPorównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie","reference":"PP 2306 087","norm_bases":["PP 2306 087"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopary Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie -196 °C CMC 0,4 °C Termoelektrické články Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem ponořeným v kapalném dusíku -196 °C CMC 0,4 °C PP 2306 087 Termopary Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym zanurzonym w cieklym azocie -196 °C CMC 0,4 °C Termoelektricke clanky Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem ponorenym v kapalnem dusiku -196 °C CMC 0,4 °C PP 2306 087","search_en":"Thermocouples Calibration – temperature Comparison with a standard resistance thermometer immersed in liquid nitrogen -196 °C CMC 0,4 °C PP 2306 087","search_zh":"热电偶 校准 – 温度 与浸入液氮中的标准电阻温度计比较 -196 °C CMC 0,4 °C PP 2306 087","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ba9e71d06a57cca42ff0f12d","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"2","test_object":"Termopary","test_object_en":"Thermocouples","test_object_zh":"热电偶","test_object_cs":"Termoelektrické články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 250 °C","cmc":"0,4 °C"},{"name":"","range":"od 250 °C do 450 °C","cmc":"0,6 °C"},{"name":"","range":"od 450 °C do 650 °C","cmc":"0,8 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C to 450 °C","cmc":"0,6 °C"},{"name":"","range":"450 °C to 650 °C","cmc":"0,8 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C 至 450 °C","cmc":"0,6 °C"},{"name":"","range":"450 °C 至 650 °C","cmc":"0,8 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C až 450 °C","cmc":"0,6 °C"},{"name":"","range":"450 °C až 650 °C","cmc":"0,8 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym","technique_en":"Comparison with a standard resistance thermometer in a calibration furnace","technique_zh":"在校准炉中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kalibrační peci","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard resistance thermometer in a calibration furnace"],"techniques_zh":["在校准炉中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kalibrační peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 250 °C CMC 0,4 °C\nod 250 °C do 450 °C CMC 0,6 °C\nod 450 °C do 650 °C CMC 0,8 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym","reference":"PP 2306 087","norm_bases":["PP 2306 087"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopary Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym od -30 °C do 250 °C CMC 0,4 °C od 250 °C do 450 °C CMC 0,6 °C od 450 °C do 650 °C CMC 0,8 °C Termoelektrické články Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kalibrační peci -30 °C až 250 °C CMC 0,4 °C 250 °C až 450 °C CMC 0,6 °C 450 °C až 650 °C CMC 0,8 °C PP 2306 087 Termopary Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym od -30 °C do 250 °C CMC 0,4 °C od 250 °C do 450 °C CMC 0,6 °C od 450 °C do 650 °C CMC 0,8 °C Termoelektricke clanky Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kalibracni peci -30 °C az 250 °C CMC 0,4 °C 250 °C az 450 °C CMC 0,6 °C 450 °C az 650 °C CMC 0,8 °C PP 2306 087","search_en":"Thermocouples Calibration – temperature Comparison with a standard resistance thermometer in a calibration furnace -30 °C to 250 °C CMC 0,4 °C 250 °C to 450 °C CMC 0,6 °C 450 °C to 650 °C CMC 0,8 °C PP 2306 087","search_zh":"热电偶 校准 – 温度 在校准炉中与标准电阻温度计比较 -30 °C 至 250 °C CMC 0,4 °C 250 °C 至 450 °C CMC 0,6 °C 450 °C 至 650 °C CMC 0,8 °C PP 2306 087","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f54f0f6dcd90a520951461e3","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"2","test_object":"Termopary","test_object_en":"Thermocouples","test_object_zh":"热电偶","test_object_cs":"Termoelektrické články","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 650 °C do 850 °C","cmc":"1,3 °C"},{"name":"","range":"od 850 °C do 1100 °C","cmc":"2,5 °C"}],"parameters_en":[{"name":"","range":"650 °C to 850 °C","cmc":"1,3 °C"},{"name":"","range":"850 °C to 1100 °C","cmc":"2,5 °C"}],"parameters_zh":[{"name":"","range":"650 °C 至 850 °C","cmc":"1,3 °C"},{"name":"","range":"850 °C 至 1100 °C","cmc":"2,5 °C"}],"parameters_cs":[{"name":"","range":"650 °C až 850 °C","cmc":"1,3 °C"},{"name":"","range":"850 °C až 1100 °C","cmc":"2,5 °C"}],"technique":"Porównanie z termoparą wzorcową w piecu kalibracyjnym","technique_en":"Comparison with a standard thermocouple in a calibration furnace","technique_zh":"在校准炉中与标准热电偶比较","technique_cs":"Porovnání s etalonovým termočlánkem v kalibrační peci","techniques":["Porównanie z termoparą wzorcową w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard thermocouple in a calibration furnace"],"techniques_zh":["在校准炉中与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termočlánkem v kalibrační peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 650 °C do 850 °C CMC 1,3 °C\nod 850 °C do 1100 °C CMC 2,5 °C\nPorównanie z termoparą wzorcową w piecu kalibracyjnym","reference":"PP 2306 087","norm_bases":["PP 2306 087"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopary Wzorcowanie – temperatura Porównanie z termoparą wzorcową w piecu kalibracyjnym od 650 °C do 850 °C CMC 1,3 °C od 850 °C do 1100 °C CMC 2,5 °C Termoelektrické články Kalibrace – teplota Porovnání s etalonovým termočlánkem v kalibrační peci 650 °C až 850 °C CMC 1,3 °C 850 °C až 1100 °C CMC 2,5 °C PP 2306 087 Termopary Wzorcowanie – temperatura Porownanie z termopara wzorcowa w piecu kalibracyjnym od 650 °C do 850 °C CMC 1,3 °C od 850 °C do 1100 °C CMC 2,5 °C Termoelektricke clanky Kalibrace – teplota Porovnani s etalonovym termoclankem v kalibracni peci 650 °C az 850 °C CMC 1,3 °C 850 °C az 1100 °C CMC 2,5 °C PP 2306 087","search_en":"Thermocouples Calibration – temperature Comparison with a standard thermocouple in a calibration furnace 650 °C to 850 °C CMC 1,3 °C 850 °C to 1100 °C CMC 2,5 °C PP 2306 087","search_zh":"热电偶 校准 – 温度 在校准炉中与标准热电偶比较 650 °C 至 850 °C CMC 1,3 °C 850 °C 至 1100 °C CMC 2,5 °C PP 2306 087","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"de9c76f8095029ed10375854","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"3","test_object":"Termometry cyfrowe i tory pomiarowe","test_object_en":"Digital thermometers and measuring chains","test_object_zh":"数字温度计和测量链","test_object_cs":"Číslicové teploměry a měřicí řetězce","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,15 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,15 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,15 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie","technique_en":"Comparison with a standard resistance thermometer immersed in liquid nitrogen","technique_zh":"与浸入液氮中的标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem ponořeným v kapalném dusíku","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie"],"techniques_en":["Comparison with a standard resistance thermometer immersed in liquid nitrogen"],"techniques_zh":["与浸入液氮中的标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem ponořeným v kapalném dusíku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n-196 °C CMC 0,15 °C\nPorównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie","reference":"PP 2306 082, PP 2306 087","norm_bases":["PP 2306 082","PP 2306 087"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry cyfrowe i tory pomiarowe Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym zanurzonym w ciekłym azocie -196 °C CMC 0,15 °C Číslicové teploměry a měřicí řetězce Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem ponořeným v kapalném dusíku -196 °C CMC 0,15 °C PP 2306 082, PP 2306 087 Termometry cyfrowe i tory pomiarowe Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym zanurzonym w cieklym azocie -196 °C CMC 0,15 °C Cislicove teplomery a merici retezce Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem ponorenym v kapalnem dusiku -196 °C CMC 0,15 °C PP 2306 082, PP 2306 087","search_en":"Digital thermometers and measuring chains Calibration – temperature Comparison with a standard resistance thermometer immersed in liquid nitrogen -196 °C CMC 0,15 °C PP 2306 082, PP 2306 087","search_zh":"数字温度计和测量链 校准 – 温度 与浸入液氮中的标准电阻温度计比较 -196 °C CMC 0,15 °C PP 2306 082, PP 2306 087","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"020665cd7bec1cffa3895a8d","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"3","test_object":"Termometry cyfrowe i tory pomiarowe","test_object_en":"Digital thermometers and measuring chains","test_object_zh":"数字温度计和测量链","test_object_cs":"Číslicové teploměry a měřicí řetězce","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 0 °C","cmc":"0,06 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"0,13 °C"},{"name":"","range":"od 50 °C do 150 °C","cmc":"0,20 °C"},{"name":"","range":"od 150 °C do 250 °C","cmc":"0,27 °C"},{"name":"","range":"od 250 °C do 450 °C","cmc":"0,47 °C"},{"name":"","range":"od 450 °C do 550 °C","cmc":"0,57 °C"},{"name":"","range":"od 550 °C do 650 °C","cmc":"0,67 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"0,13 °C"},{"name":"","range":"50 °C to 150 °C","cmc":"0,20 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,27 °C"},{"name":"","range":"250 °C to 450 °C","cmc":"0,47 °C"},{"name":"","range":"450 °C to 550 °C","cmc":"0,57 °C"},{"name":"","range":"550 °C to 650 °C","cmc":"0,67 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"0,13 °C"},{"name":"","range":"50 °C 至 150 °C","cmc":"0,20 °C"},{"name":"","range":"150 °C 至 250 °C","cmc":"0,27 °C"},{"name":"","range":"250 °C 至 450 °C","cmc":"0,47 °C"},{"name":"","range":"450 °C 至 550 °C","cmc":"0,57 °C"},{"name":"","range":"550 °C 至 650 °C","cmc":"0,67 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 0 °C","cmc":"0,06 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"0,13 °C"},{"name":"","range":"50 °C až 150 °C","cmc":"0,20 °C"},{"name":"","range":"150 °C až 250 °C","cmc":"0,27 °C"},{"name":"","range":"250 °C až 450 °C","cmc":"0,47 °C"},{"name":"","range":"450 °C až 550 °C","cmc":"0,57 °C"},{"name":"","range":"550 °C až 650 °C","cmc":"0,67 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym","technique_en":"Comparison with a standard resistance thermometer in a calibration furnace","technique_zh":"在校准炉中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kalibrační peci","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard resistance thermometer in a calibration furnace"],"techniques_zh":["在校准炉中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kalibrační peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 0 °C CMC 0,06 °C\nod 0 °C do 50 °C CMC 0,13 °C\nod 50 °C do 150 °C CMC 0,20 °C\nod 150 °C do 250 °C CMC 0,27 °C\nod 250 °C do 450 °C CMC 0,47 °C\nod 450 °C do 550 °C CMC 0,57 °C\nod 550 °C do 650 °C CMC 0,67 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym","reference":"PP 2306 082, PP 2306 087","norm_bases":["PP 2306 082","PP 2306 087"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry cyfrowe i tory pomiarowe Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym od -30 °C do 0 °C CMC 0,06 °C od 0 °C do 50 °C CMC 0,13 °C od 50 °C do 150 °C CMC 0,20 °C od 150 °C do 250 °C CMC 0,27 °C od 250 °C do 450 °C CMC 0,47 °C od 450 °C do 550 °C CMC 0,57 °C od 550 °C do 650 °C CMC 0,67 °C Číslicové teploměry a měřicí řetězce Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kalibrační peci -30 °C až 0 °C CMC 0,06 °C 0 °C až 50 °C CMC 0,13 °C 50 °C až 150 °C CMC 0,20 °C 150 °C až 250 °C CMC 0,27 °C 250 °C až 450 °C CMC 0,47 °C 450 °C až 550 °C CMC 0,57 °C 550 °C až 650 °C CMC 0,67 °C PP 2306 082, PP 2306 087 Termometry cyfrowe i tory pomiarowe Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym od -30 °C do 0 °C CMC 0,06 °C od 0 °C do 50 °C CMC 0,13 °C od 50 °C do 150 °C CMC 0,20 °C od 150 °C do 250 °C CMC 0,27 °C od 250 °C do 450 °C CMC 0,47 °C od 450 °C do 550 °C CMC 0,57 °C od 550 °C do 650 °C CMC 0,67 °C Cislicove teplomery a merici retezce Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kalibracni peci -30 °C az 0 °C CMC 0,06 °C 0 °C az 50 °C CMC 0,13 °C 50 °C az 150 °C CMC 0,20 °C 150 °C az 250 °C CMC 0,27 °C 250 °C az 450 °C CMC 0,47 °C 450 °C az 550 °C CMC 0,57 °C 550 °C az 650 °C CMC 0,67 °C PP 2306 082, PP 2306 087","search_en":"Digital thermometers and measuring chains Calibration – temperature Comparison with a standard resistance thermometer in a calibration furnace -30 °C to 0 °C CMC 0,06 °C 0 °C to 50 °C CMC 0,13 °C 50 °C to 150 °C CMC 0,20 °C 150 °C to 250 °C CMC 0,27 °C 250 °C to 450 °C CMC 0,47 °C 450 °C to 550 °C CMC 0,57 °C 550 °C to 650 °C CMC 0,67 °C PP 2306 082, PP 2306 087","search_zh":"数字温度计和测量链 校准 – 温度 在校准炉中与标准电阻温度计比较 -30 °C 至 0 °C CMC 0,06 °C 0 °C 至 50 °C CMC 0,13 °C 50 °C 至 150 °C CMC 0,20 °C 150 °C 至 250 °C CMC 0,27 °C 250 °C 至 450 °C CMC 0,47 °C 450 °C 至 550 °C CMC 0,57 °C 550 °C 至 650 °C CMC 0,67 °C PP 2306 082, PP 2306 087","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8523dca04803f455bb64494d","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"3","test_object":"Termometry cyfrowe i tory pomiarowe","test_object_en":"Digital thermometers and measuring chains","test_object_zh":"数字温度计和测量链","test_object_cs":"Číslicové teploměry a měřicí řetězce","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 650 °C do 850 °C","cmc":"1,3 °C"},{"name":"","range":"od 850 °C do 1100 °C","cmc":"2,5 °C"}],"parameters_en":[{"name":"","range":"650 °C to 850 °C","cmc":"1,3 °C"},{"name":"","range":"850 °C to 1100 °C","cmc":"2,5 °C"}],"parameters_zh":[{"name":"","range":"650 °C 至 850 °C","cmc":"1,3 °C"},{"name":"","range":"850 °C 至 1100 °C","cmc":"2,5 °C"}],"parameters_cs":[{"name":"","range":"650 °C až 850 °C","cmc":"1,3 °C"},{"name":"","range":"850 °C až 1100 °C","cmc":"2,5 °C"}],"technique":"Porównanie z termoparą wzorcową w piecu kalibracyjnym","technique_en":"Comparison with a standard thermocouple in a calibration furnace","technique_zh":"在校准炉中与标准热电偶比较","technique_cs":"Porovnání s etalonovým termočlánkem v kalibrační peci","techniques":["Porównanie z termoparą wzorcową w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard thermocouple in a calibration furnace"],"techniques_zh":["在校准炉中与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termočlánkem v kalibrační peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 650 °C do 850 °C CMC 1,3 °C\nod 850 °C do 1100 °C CMC 2,5 °C\nPorównanie z termoparą wzorcową w piecu kalibracyjnym","reference":"PP 2306 082, PP 2306 087","norm_bases":["PP 2306 082","PP 2306 087"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry cyfrowe i tory pomiarowe Wzorcowanie – temperatura Porównanie z termoparą wzorcową w piecu kalibracyjnym od 650 °C do 850 °C CMC 1,3 °C od 850 °C do 1100 °C CMC 2,5 °C Číslicové teploměry a měřicí řetězce Kalibrace – teplota Porovnání s etalonovým termočlánkem v kalibrační peci 650 °C až 850 °C CMC 1,3 °C 850 °C až 1100 °C CMC 2,5 °C PP 2306 082, PP 2306 087 Termometry cyfrowe i tory pomiarowe Wzorcowanie – temperatura Porownanie z termopara wzorcowa w piecu kalibracyjnym od 650 °C do 850 °C CMC 1,3 °C od 850 °C do 1100 °C CMC 2,5 °C Cislicove teplomery a merici retezce Kalibrace – teplota Porovnani s etalonovym termoclankem v kalibracni peci 650 °C az 850 °C CMC 1,3 °C 850 °C az 1100 °C CMC 2,5 °C PP 2306 082, PP 2306 087","search_en":"Digital thermometers and measuring chains Calibration – temperature Comparison with a standard thermocouple in a calibration furnace 650 °C to 850 °C CMC 1,3 °C 850 °C to 1100 °C CMC 2,5 °C PP 2306 082, PP 2306 087","search_zh":"数字温度计和测量链 校准 – 温度 在校准炉中与标准热电偶比较 650 °C 至 850 °C CMC 1,3 °C 850 °C 至 1100 °C CMC 2,5 °C PP 2306 082, PP 2306 087","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc3cdf3ef10f4c76f6d59878","lab_id":"6ade8b37ff0682476170811c","country":"CZ","accr_number":"2340","accr_body":"ČIA","row_label":"4","test_object":"Tory pomiarowe temperatury wraz z komorą temperaturową","test_object_en":"Temperature measuring chains including a temperature chamber","test_object_zh":"含温度箱的温度测量链","test_object_cs":"Měřicí řetězce teploty včetně teplotní komory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -190 °C do -100 °C","cmc":"1,3 °C"},{"name":"","range":"od -100 °C do 320 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-190 °C to -100 °C","cmc":"1,3 °C"},{"name":"","range":"-100 °C to 320 °C","cmc":"1,2 °C"}],"parameters_zh":[{"name":"","range":"-190 °C 至 -100 °C","cmc":"1,3 °C"},{"name":"","range":"-100 °C 至 320 °C","cmc":"1,2 °C"}],"parameters_cs":[{"name":"","range":"-190 °C až -100 °C","cmc":"1,3 °C"},{"name":"","range":"-100 °C až 320 °C","cmc":"1,2 °C"}],"technique":"Porównanie z termoparą wzorcową","technique_en":"Comparison with a standard thermocouple","technique_zh":"与标准热电偶比较","technique_cs":"Porovnání s etalonovým termoelektrickým článkem","techniques":["Porównanie z termoparą wzorcową"],"techniques_en":["Comparison with a standard thermocouple"],"techniques_zh":["与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým článkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -190 °C do -100 °C CMC 1,3 °C\nod -100 °C do 320 °C CMC 1,2 °C\nPorównanie z termoparą wzorcową","reference":"PP 2306 087","norm_bases":["PP 2306 087"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe temperatury wraz z komorą temperaturową Wzorcowanie – temperatura Porównanie z termoparą wzorcową od -190 °C do -100 °C CMC 1,3 °C od -100 °C do 320 °C CMC 1,2 °C Měřicí řetězce teploty včetně teplotní komory Kalibrace – teplota Porovnání s etalonovým termoelektrickým článkem -190 °C až -100 °C CMC 1,3 °C -100 °C až 320 °C CMC 1,2 °C PP 2306 087 Tory pomiarowe temperatury wraz z komora temperaturowa Wzorcowanie – temperatura Porownanie z termopara wzorcowa od -190 °C do -100 °C CMC 1,3 °C od -100 °C do 320 °C CMC 1,2 °C Merici retezce teploty vcetne teplotni komory Kalibrace – teplota Porovnani s etalonovym termoelektrickym clankem -190 °C az -100 °C CMC 1,3 °C -100 °C az 320 °C CMC 1,2 °C PP 2306 087","search_en":"Temperature measuring chains including a temperature chamber Calibration – temperature Comparison with a standard thermocouple -190 °C to -100 °C CMC 1,3 °C -100 °C to 320 °C CMC 1,2 °C PP 2306 087","search_zh":"含温度箱的温度测量链 校准 – 温度 与标准热电偶比较 -190 °C 至 -100 °C CMC 1,3 °C -100 °C 至 320 °C CMC 1,2 °C PP 2306 087","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}