{"lab":{"_id":"6acfffe7ff06824761705e14","accr_number":"2339","country":"CZ","accr_body":"ČIA","address":"V Parku 2336/22, 140 00 Praha 4","categories":["metrology"],"city":"Praha 4","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4962423,50.026324]},"map_coord":[50.026324,14.4962423],"map_geo":"cai-mapa","methods_count":17,"name":"Industrial Technique Service s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: kąt obrotu i moment siły, w zakresie określonym w załączniku do świadectwa.","search_text":"industrial technique service s.r.o. v parku 2336/22, 140 00 praha 4 2339","source_page_url":"https://www.cai.cz/?subjekt=2339-industrial-technique-service-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"11-08-2030","website":"www.its-ee.com","certificate_date":"11.08.2025","certificate_no":"419/2025","certificate_replaces":"357/2024 z 23.07.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: kąt obrotu i moment siły, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of rotation angle and torque to the extent as specified in the appendix to this Certificate.","zh":"旋转角和扭矩领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech úhel otočení a moment síly, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące ITS","lab_division_cs":"Kalibrační laboratoř ITS","lab_division_en":"ITS Calibration Laboratory","lab_division_zh":"ITS 校准实验室","lab_locations":[{"name":"Laboratorium Průmyslová","address":"Průmyslová 1428/10","city":"Praha 10, Česká republika","postal":"102 00"},{"name":"Laboratorium CSW","address":"Rózyniec 83C","city":"Gromadka, Polsko","postal":"59-706"},{"name":"Laboratorium Chodov","address":"V Parku 2336/22","city":"Praha 4, Česká republika","postal":"140 00"}],"lab_locations_en":[{"name":"Laboratory Průmyslová","address":"Průmyslová 1428/10","city":"Praha 10, Česká republika","postal":"102 00"},{"name":"Laboratory CSW","address":"Rózyniec 83C","city":"Gromadka, Polsko","postal":"59-706"},{"name":"Laboratory Chodov","address":"V Parku 2336/22","city":"Praha 4, Česká republika","postal":"140 00"}],"lab_locations_zh":[{"name":"Průmyslová 实验室","address":"Průmyslová 1428/10","city":"Praha 10, Česká republika","postal":"102 00"},{"name":"CSW 实验室","address":"Rózyniec 83C","city":"Gromadka, Polsko","postal":"59-706"},{"name":"Chodov 实验室","address":"V Parku 2336/22","city":"Praha 4, Česká republika","postal":"140 00"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"28104e92dedf18b5b2032753dbd72c1bcd79171831d70b907d401709bd36df1a","source_pdf_url":"https://www.cai.cz/OA/pdf/419_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/419_2025_EN.pdf"},"methods":[{"_id":"d9b9dd0996bfce8451ab0850","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"1","test_object":"Kąt obrotu ręcznych narzędzi dynamometrycznych","test_object_en":"Rotation angle of hand torque tools","test_object_zh":"手动扭矩工具的旋转角","test_object_cs":"Úhel otočení ručního momentového nářadí","methodology":"Wzorcowanie – kąt obrotu","methodology_en":"Calibration – rotation angle","methodology_zh":"校准 – 旋转角","methodology_cs":"Kalibrace – úhel otočení","parameters":[{"name":"","range":"od 0 ° do n·360 °","cmc":"1,0°"}],"parameters_en":[{"name":"","range":"0 ° to n·360 °","cmc":"1,0°"}],"parameters_zh":[{"name":"","range":"0 ° 至 n·360 °","cmc":"1,0°"}],"parameters_cs":[{"name":"","range":"0 ° až n·360 °","cmc":"1,0°"}],"technique":"Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2","technique_en":"Measurement with a rotation angle transducer VDI/VDE 2648 Part 1, Part 2","technique_zh":"用旋转角度传感器测量 VDI/VDE 2648 Part 1, Part 2","technique_cs":"Měření snímačem úhlu otočení VDI/VDE 2648 Part 1, Part 2","techniques":["Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2"],"techniques_en":["Measurement with a rotation angle transducer VDI/VDE 2648 Part 1, Part 2"],"techniques_zh":["用旋转角度传感器测量 VDI/VDE 2648 Part 1, Part 2"],"techniques_cs":["Měření snímačem úhlu otočení VDI/VDE 2648 Part 1, Part 2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt obrotu\nod 0 ° do n·360 ° CMC 1,0°\nPomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2","reference":"ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","norm_bases":["ITS-10-14-AV","ITS-10-14-AV/C","ITS-12-14-AK"],"lab_section":"Laboratorium Průmyslová","lab_section_en":"Laboratory Průmyslová","lab_section_zh":"Průmyslová 实验室","lab_section_cs":"Laboratoř Průmyslová","lab_address":"Průmyslová 1428/10, 102 00 Praha 10, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt obrotu","regulatory_area_en":"CMC for the field of measured quantity: Rotation angle","regulatory_area_zh":"被测量领域的CMC：旋转角","regulatory_area_cs":"CMC pro obor měřené veličiny: Úhel otočení","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu ręcznych narzędzi dynamometrycznych Wzorcowanie – kąt obrotu Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2 od 0 ° do n·360 ° CMC 1,0° Úhel otočení ručního momentového nářadí Kalibrace – úhel otočení Měření snímačem úhlu otočení VDI/VDE 2648 Part 1, Part 2 0 ° až n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK Kat obrotu recznych narzedzi dynamometrycznych Wzorcowanie – kat obrotu Pomiar czujnikiem kata obrotu VDI/VDE 2648 Part 1, Part 2 od 0 ° do n·360 ° CMC 1,0° Uhel otoceni rucniho momentoveho naradi Kalibrace – uhel otoceni Mereni snimacem uhlu otoceni VDI/VDE 2648 Part 1, Part 2 0 ° az n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","search_en":"Rotation angle of hand torque tools Calibration – rotation angle Measurement with a rotation angle transducer VDI/VDE 2648 Part 1, Part 2 0 ° to n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","search_zh":"手动扭矩工具的旋转角 校准 – 旋转角 用旋转角度传感器测量 VDI/VDE 2648 Part 1, Part 2 0 ° 至 n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d3f3f462e630586fe306a1c","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"1","test_object":"Kąt obrotu ręcznych narzędzi dynamometrycznych","test_object_en":"Rotation angle of hand torque tools","test_object_zh":"手动扭矩工具的旋转角","test_object_cs":"Úhel otočení ručního momentového nářadí","methodology":"Wzorcowanie – kąt obrotu","methodology_en":"Calibration – rotation angle","methodology_zh":"校准 – 旋转角","methodology_cs":"Kalibrace – úhel otočení","parameters":[{"name":"","range":"od 0 ° do n·360 °","cmc":"1,0°"}],"parameters_en":[{"name":"","range":"0 ° to n·360 °","cmc":"1,0°"}],"parameters_zh":[{"name":"","range":"0 ° 至 n·360 °","cmc":"1,0°"}],"parameters_cs":[{"name":"","range":"0 ° až n·360 °","cmc":"1,0°"}],"technique":"Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2","technique_en":"Measurement with a rotation angle transducer VDI/VDE 2648 Part 1, Part 2","technique_zh":"用旋转角度传感器测量 VDI/VDE 2648 Part 1, Part 2","technique_cs":"Měření snímačem úhlu otočení VDI/VDE 2648 Part 1, Part 2","techniques":["Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2"],"techniques_en":["Measurement with a rotation angle transducer VDI/VDE 2648 Part 1, Part 2"],"techniques_zh":["用旋转角度传感器测量 VDI/VDE 2648 Part 1, Part 2"],"techniques_cs":["Měření snímačem úhlu otočení VDI/VDE 2648 Part 1, Part 2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt obrotu\nod 0 ° do n·360 ° CMC 1,0°\nPomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2","reference":"ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","norm_bases":["ITS-10-14-AV","ITS-10-14-AV/C","ITS-12-14-AK"],"lab_section":"Laboratorium Chodov","lab_section_en":"Laboratory Chodov","lab_section_zh":"Chodov 实验室","lab_section_cs":"Laboratoř Chodov","lab_address":"V Parku 2336/22, 140 00 Praha 4, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt obrotu","regulatory_area_en":"CMC for the field of measured quantity: Rotation angle","regulatory_area_zh":"被测量领域的CMC：旋转角","regulatory_area_cs":"CMC pro obor měřené veličiny: Úhel otočení","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu ręcznych narzędzi dynamometrycznych Wzorcowanie – kąt obrotu Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1, Part 2 od 0 ° do n·360 ° CMC 1,0° Úhel otočení ručního momentového nářadí Kalibrace – úhel otočení Měření snímačem úhlu otočení VDI/VDE 2648 Part 1, Part 2 0 ° až n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK Kat obrotu recznych narzedzi dynamometrycznych Wzorcowanie – kat obrotu Pomiar czujnikiem kata obrotu VDI/VDE 2648 Part 1, Part 2 od 0 ° do n·360 ° CMC 1,0° Uhel otoceni rucniho momentoveho naradi Kalibrace – uhel otoceni Mereni snimacem uhlu otoceni VDI/VDE 2648 Part 1, Part 2 0 ° az n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","search_en":"Rotation angle of hand torque tools Calibration – rotation angle Measurement with a rotation angle transducer VDI/VDE 2648 Part 1, Part 2 0 ° to n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","search_zh":"手动扭矩工具的旋转角 校准 – 旋转角 用旋转角度传感器测量 VDI/VDE 2648 Part 1, Part 2 0 ° 至 n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C, ITS-12-14-AK","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a514a8155408be3e79bdae2e","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"2","test_object":"Kąt obrotu ręcznych narzędzi dynamometrycznych","test_object_en":"Rotation angle of hand torque tools","test_object_zh":"手动扭矩工具的旋转角","test_object_cs":"Úhel otočení ručního momentového nářadí","methodology":"Wzorcowanie – kąt obrotu","methodology_en":"Calibration – rotation angle","methodology_zh":"校准 – 旋转角","methodology_cs":"Kalibrace – úhel otočení","parameters":[{"name":"","range":"od 0 ° do n·360 °","cmc":"0,55°"}],"parameters_en":[{"name":"","range":"0 ° to n·360 °","cmc":"0,55°"}],"parameters_zh":[{"name":"","range":"0 ° 至 n·360 °","cmc":"0,55°"}],"parameters_cs":[{"name":"","range":"0 ° až n·360 °","cmc":"0,55°"}],"technique":"Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2","technique_en":"Measurement with a rotation angle transducer VDI/VDE 2648 Part 2","technique_zh":"用旋转角度传感器测量 VDI/VDE 2648 Part 2","technique_cs":"Měření snímačem úhlu otočení VDI/VDE 2648 Part 2","techniques":["Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2"],"techniques_en":["Measurement with a rotation angle transducer VDI/VDE 2648 Part 2"],"techniques_zh":["用旋转角度传感器测量 VDI/VDE 2648 Part 2"],"techniques_cs":["Měření snímačem úhlu otočení VDI/VDE 2648 Part 2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt obrotu\nod 0 ° do n·360 ° CMC 0,55°\nPomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2","reference":"ITS-13-14-LAK, ITS-12-14-AK","norm_bases":["ITS-13-14-LAK","ITS-12-14-AK"],"lab_section":"Laboratorium Průmyslová","lab_section_en":"Laboratory Průmyslová","lab_section_zh":"Průmyslová 实验室","lab_section_cs":"Laboratoř Průmyslová","lab_address":"Průmyslová 1428/10, 102 00 Praha 10, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt obrotu","regulatory_area_en":"CMC for the field of measured quantity: Rotation angle","regulatory_area_zh":"被测量领域的CMC：旋转角","regulatory_area_cs":"CMC pro obor měřené veličiny: Úhel otočení","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu ręcznych narzędzi dynamometrycznych Wzorcowanie – kąt obrotu Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2 od 0 ° do n·360 ° CMC 0,55° Úhel otočení ručního momentového nářadí Kalibrace – úhel otočení Měření snímačem úhlu otočení VDI/VDE 2648 Part 2 0 ° až n·360 ° CMC 0,55° ITS-13-14-LAK, ITS-12-14-AK Kat obrotu recznych narzedzi dynamometrycznych Wzorcowanie – kat obrotu Pomiar czujnikiem kata obrotu VDI/VDE 2648 Part 2 od 0 ° do n·360 ° CMC 0,55° Uhel otoceni rucniho momentoveho naradi Kalibrace – uhel otoceni Mereni snimacem uhlu otoceni VDI/VDE 2648 Part 2 0 ° az n·360 ° CMC 0,55° ITS-13-14-LAK, ITS-12-14-AK","search_en":"Rotation angle of hand torque tools Calibration – rotation angle Measurement with a rotation angle transducer VDI/VDE 2648 Part 2 0 ° to n·360 ° CMC 0,55° ITS-13-14-LAK, ITS-12-14-AK","search_zh":"手动扭矩工具的旋转角 校准 – 旋转角 用旋转角度传感器测量 VDI/VDE 2648 Part 2 0 ° 至 n·360 ° CMC 0,55° ITS-13-14-LAK, ITS-12-14-AK","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"edabf1f01ba465e7d56ed8c3","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"3","test_object":"Kąt obrotu ręcznych narzędzi dynamometrycznych","test_object_en":"Rotation angle of hand torque tools","test_object_zh":"手动扭矩工具的旋转角","test_object_cs":"Úhel otočení ručního momentového nářadí","methodology":"Wzorcowanie – kąt obrotu","methodology_en":"Calibration – rotation angle","methodology_zh":"校准 – 旋转角","methodology_cs":"Kalibrace – úhel otočení","parameters":[{"name":"","range":"od 0 ° do n·360 °","cmc":"0,90°"}],"parameters_en":[{"name":"","range":"0 ° to n·360 °","cmc":"0,90°"}],"parameters_zh":[{"name":"","range":"0 ° 至 n·360 °","cmc":"0,90°"}],"parameters_cs":[{"name":"","range":"0 ° až n·360 °","cmc":"0,90°"}],"technique":"Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2","technique_en":"Measurement with a rotation angle transducer VDI/VDE 2648 Part 2","technique_zh":"用旋转角度传感器测量 VDI/VDE 2648 Part 2","technique_cs":"Měření snímačem úhlu otočení VDI/VDE 2648 Part 2","techniques":["Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2"],"techniques_en":["Measurement with a rotation angle transducer VDI/VDE 2648 Part 2"],"techniques_zh":["用旋转角度传感器测量 VDI/VDE 2648 Part 2"],"techniques_cs":["Měření snímačem úhlu otočení VDI/VDE 2648 Part 2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt obrotu\nod 0 ° do n·360 ° CMC 0,90°\nPomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2","reference":"ITS-13-14-LAK, ITS-12-14-AK","norm_bases":["ITS-13-14-LAK","ITS-12-14-AK"],"lab_section":"Laboratorium CSW","lab_section_en":"Laboratory CSW","lab_section_zh":"CSW 实验室","lab_section_cs":"Laboratoř CSW","lab_address":"Rózyniec 83C, 59-706 Gromadka, Polsko","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt obrotu","regulatory_area_en":"CMC for the field of measured quantity: Rotation angle","regulatory_area_zh":"被测量领域的CMC：旋转角","regulatory_area_cs":"CMC pro obor měřené veličiny: Úhel otočení","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu ręcznych narzędzi dynamometrycznych Wzorcowanie – kąt obrotu Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 2 od 0 ° do n·360 ° CMC 0,90° Úhel otočení ručního momentového nářadí Kalibrace – úhel otočení Měření snímačem úhlu otočení VDI/VDE 2648 Part 2 0 ° až n·360 ° CMC 0,90° ITS-13-14-LAK, ITS-12-14-AK Kat obrotu recznych narzedzi dynamometrycznych Wzorcowanie – kat obrotu Pomiar czujnikiem kata obrotu VDI/VDE 2648 Part 2 od 0 ° do n·360 ° CMC 0,90° Uhel otoceni rucniho momentoveho naradi Kalibrace – uhel otoceni Mereni snimacem uhlu otoceni VDI/VDE 2648 Part 2 0 ° az n·360 ° CMC 0,90° ITS-13-14-LAK, ITS-12-14-AK","search_en":"Rotation angle of hand torque tools Calibration – rotation angle Measurement with a rotation angle transducer VDI/VDE 2648 Part 2 0 ° to n·360 ° CMC 0,90° ITS-13-14-LAK, ITS-12-14-AK","search_zh":"手动扭矩工具的旋转角 校准 – 旋转角 用旋转角度传感器测量 VDI/VDE 2648 Part 2 0 ° 至 n·360 ° CMC 0,90° ITS-13-14-LAK, ITS-12-14-AK","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2ef2f59728ac21e7568e038","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"4","test_object":"Kąt obrotu ręcznych narzędzi dynamometrycznych","test_object_en":"Rotation angle of hand torque tools","test_object_zh":"手动扭矩工具的旋转角","test_object_cs":"Úhel otočení ručního momentového nářadí","methodology":"Wzorcowanie – kąt obrotu","methodology_en":"Calibration – rotation angle","methodology_zh":"校准 – 旋转角","methodology_cs":"Kalibrace – úhel otočení","parameters":[{"name":"","range":"od 0 ° do n·360 °","cmc":"1,0°"}],"parameters_en":[{"name":"","range":"0 ° to n·360 °","cmc":"1,0°"}],"parameters_zh":[{"name":"","range":"0 ° 至 n·360 °","cmc":"1,0°"}],"parameters_cs":[{"name":"","range":"0 ° až n·360 °","cmc":"1,0°"}],"technique":"Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1","technique_en":"Measurement with a rotation angle transducer VDI/VDE 2648 Part 1","technique_zh":"用旋转角度传感器测量 VDI/VDE 2648 Part 1","technique_cs":"Měření snímačem úhlu otočení VDI/VDE 2648 Part 1","techniques":["Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1"],"techniques_en":["Measurement with a rotation angle transducer VDI/VDE 2648 Part 1"],"techniques_zh":["用旋转角度传感器测量 VDI/VDE 2648 Part 1"],"techniques_cs":["Měření snímačem úhlu otočení VDI/VDE 2648 Part 1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt obrotu\nod 0 ° do n·360 ° CMC 1,0°\nPomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1","reference":"ITS-10-14-AV, ITS-10-14-AV/C","norm_bases":["ITS-10-14-AV","ITS-10-14-AV/C"],"lab_section":"Laboratorium CSW","lab_section_en":"Laboratory CSW","lab_section_zh":"CSW 实验室","lab_section_cs":"Laboratoř CSW","lab_address":"Rózyniec 83C, 59-706 Gromadka, Polsko","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt obrotu","regulatory_area_en":"CMC for the field of measured quantity: Rotation angle","regulatory_area_zh":"被测量领域的CMC：旋转角","regulatory_area_cs":"CMC pro obor měřené veličiny: Úhel otočení","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu ręcznych narzędzi dynamometrycznych Wzorcowanie – kąt obrotu Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1 od 0 ° do n·360 ° CMC 1,0° Úhel otočení ručního momentového nářadí Kalibrace – úhel otočení Měření snímačem úhlu otočení VDI/VDE 2648 Part 1 0 ° až n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C Kat obrotu recznych narzedzi dynamometrycznych Wzorcowanie – kat obrotu Pomiar czujnikiem kata obrotu VDI/VDE 2648 Part 1 od 0 ° do n·360 ° CMC 1,0° Uhel otoceni rucniho momentoveho naradi Kalibrace – uhel otoceni Mereni snimacem uhlu otoceni VDI/VDE 2648 Part 1 0 ° az n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C","search_en":"Rotation angle of hand torque tools Calibration – rotation angle Measurement with a rotation angle transducer VDI/VDE 2648 Part 1 0 ° to n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C","search_zh":"手动扭矩工具的旋转角 校准 – 旋转角 用旋转角度传感器测量 VDI/VDE 2648 Part 1 0 ° 至 n·360 ° CMC 1,0° ITS-10-14-AV, ITS-10-14-AV/C","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a6aaf7bf829ae7fd2dd886fc","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"5","test_object":"Kąt obrotu czujników","test_object_en":"Rotation angle of transducers","test_object_zh":"传感器的旋转角","test_object_cs":"Úhel otočení snímačů","methodology":"Wzorcowanie – kąt obrotu","methodology_en":"Calibration – rotation angle","methodology_zh":"校准 – 旋转角","methodology_cs":"Kalibrace – úhel otočení","parameters":[{"name":"","range":"od 0 ° do n·360 °","cmc":"0,10°"}],"parameters_en":[{"name":"","range":"0 ° to n·360 °","cmc":"0,10°"}],"parameters_zh":[{"name":"","range":"0 ° 至 n·360 °","cmc":"0,10°"}],"parameters_cs":[{"name":"","range":"0 ° až n·360 °","cmc":"0,10°"}],"technique":"Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1","technique_en":"Measurement with a rotation angle transducer VDI/VDE 2648 Part 1","technique_zh":"用旋转角度传感器测量 VDI/VDE 2648 Part 1","technique_cs":"Měření snímačem úhlu otočení VDI/VDE 2648 Part 1","techniques":["Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1"],"techniques_en":["Measurement with a rotation angle transducer VDI/VDE 2648 Part 1"],"techniques_zh":["用旋转角度传感器测量 VDI/VDE 2648 Part 1"],"techniques_cs":["Měření snímačem úhlu otočení VDI/VDE 2648 Part 1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt obrotu\nod 0 ° do n·360 ° CMC 0,10°\nPomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1","reference":"ITS-11-14-AS","norm_bases":["ITS-11-14-AS"],"lab_section":"Laboratorium Průmyslová","lab_section_en":"Laboratory Průmyslová","lab_section_zh":"Průmyslová 实验室","lab_section_cs":"Laboratoř Průmyslová","lab_address":"Průmyslová 1428/10, 102 00 Praha 10, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt obrotu","regulatory_area_en":"CMC for the field of measured quantity: Rotation angle","regulatory_area_zh":"被测量领域的CMC：旋转角","regulatory_area_cs":"CMC pro obor měřené veličiny: Úhel otočení","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu czujników Wzorcowanie – kąt obrotu Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1 od 0 ° do n·360 ° CMC 0,10° Úhel otočení snímačů Kalibrace – úhel otočení Měření snímačem úhlu otočení VDI/VDE 2648 Part 1 0 ° až n·360 ° CMC 0,10° ITS-11-14-AS Kat obrotu czujnikow Wzorcowanie – kat obrotu Pomiar czujnikiem kata obrotu VDI/VDE 2648 Part 1 od 0 ° do n·360 ° CMC 0,10° Uhel otoceni snimacu Kalibrace – uhel otoceni Mereni snimacem uhlu otoceni VDI/VDE 2648 Part 1 0 ° az n·360 ° CMC 0,10° ITS-11-14-AS","search_en":"Rotation angle of transducers Calibration – rotation angle Measurement with a rotation angle transducer VDI/VDE 2648 Part 1 0 ° to n·360 ° CMC 0,10° ITS-11-14-AS","search_zh":"传感器的旋转角 校准 – 旋转角 用旋转角度传感器测量 VDI/VDE 2648 Part 1 0 ° 至 n·360 ° CMC 0,10° ITS-11-14-AS","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9253353c1c2d927531f3c41b","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"5","test_object":"Kąt obrotu czujników","test_object_en":"Rotation angle of transducers","test_object_zh":"传感器的旋转角","test_object_cs":"Úhel otočení snímačů","methodology":"Wzorcowanie – kąt obrotu","methodology_en":"Calibration – rotation angle","methodology_zh":"校准 – 旋转角","methodology_cs":"Kalibrace – úhel otočení","parameters":[{"name":"","range":"od 0 ° do n·360 °","cmc":"0,10°"}],"parameters_en":[{"name":"","range":"0 ° to n·360 °","cmc":"0,10°"}],"parameters_zh":[{"name":"","range":"0 ° 至 n·360 °","cmc":"0,10°"}],"parameters_cs":[{"name":"","range":"0 ° až n·360 °","cmc":"0,10°"}],"technique":"Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1","technique_en":"Measurement with a rotation angle transducer VDI/VDE 2648 Part 1","technique_zh":"用旋转角度传感器测量 VDI/VDE 2648 Part 1","technique_cs":"Měření snímačem úhlu otočení VDI/VDE 2648 Part 1","techniques":["Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1"],"techniques_en":["Measurement with a rotation angle transducer VDI/VDE 2648 Part 1"],"techniques_zh":["用旋转角度传感器测量 VDI/VDE 2648 Part 1"],"techniques_cs":["Měření snímačem úhlu otočení VDI/VDE 2648 Part 1"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt obrotu\nod 0 ° do n·360 ° CMC 0,10°\nPomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1","reference":"ITS-11-14-AS","norm_bases":["ITS-11-14-AS"],"lab_section":"Laboratorium CSW","lab_section_en":"Laboratory CSW","lab_section_zh":"CSW 实验室","lab_section_cs":"Laboratoř CSW","lab_address":"Rózyniec 83C, 59-706 Gromadka, Polsko","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt obrotu","regulatory_area_en":"CMC for the field of measured quantity: Rotation angle","regulatory_area_zh":"被测量领域的CMC：旋转角","regulatory_area_cs":"CMC pro obor měřené veličiny: Úhel otočení","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt obrotu czujników Wzorcowanie – kąt obrotu Pomiar czujnikiem kąta obrotu VDI/VDE 2648 Part 1 od 0 ° do n·360 ° CMC 0,10° Úhel otočení snímačů Kalibrace – úhel otočení Měření snímačem úhlu otočení VDI/VDE 2648 Part 1 0 ° až n·360 ° CMC 0,10° ITS-11-14-AS Kat obrotu czujnikow Wzorcowanie – kat obrotu Pomiar czujnikiem kata obrotu VDI/VDE 2648 Part 1 od 0 ° do n·360 ° CMC 0,10° Uhel otoceni snimacu Kalibrace – uhel otoceni Mereni snimacem uhlu otoceni VDI/VDE 2648 Part 1 0 ° az n·360 ° CMC 0,10° ITS-11-14-AS","search_en":"Rotation angle of transducers Calibration – rotation angle Measurement with a rotation angle transducer VDI/VDE 2648 Part 1 0 ° to n·360 ° CMC 0,10° ITS-11-14-AS","search_zh":"传感器的旋转角 校准 – 旋转角 用旋转角度传感器测量 VDI/VDE 2648 Part 1 0 ° 至 n·360 ° CMC 0,10° ITS-11-14-AS","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0a4dba510b02d0cc45b8dac8","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"1","test_object":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu siły","test_object_en":"Rotary and static transducers, devices for measuring torque","test_object_zh":"旋转式和静态扭矩传感器、扭矩测量装置","test_object_cs":"Snímače rotační a statické,zařízení pro měření momentu síly","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 12 Nm","cmc":"0,04 %"},{"name":"","range":"od 1,5 Nm do 2000 Nm","cmc":"0,02 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 12 Nm","cmc":"0,04 %"},{"name":"","range":"1,5 Nm to 2000 Nm","cmc":"0,02 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 12 Nm","cmc":"0,04 %"},{"name":"","range":"1,5 Nm 至 2000 Nm","cmc":"0,02 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 12 Nm","cmc":"0,04 %"},{"name":"","range":"1,5 Nm až 2000 Nm","cmc":"0,02 %"}],"technique":"Pomiar porównawczy wzorcowym urządzeniem momentu siły z użyciem obciążników i ramion momentu siły EURAMET cg-14","technique_en":"Comparative measurement with a standard torque device using weights and torque arms, EURAMET cg-14","technique_zh":"使用砝码和扭矩臂的标准扭矩装置比较测量 EURAMET cg-14","technique_cs":"Porovnávací měření etalonovým zařízením momentu síly pomocí zatěžovacích těles a ramének momentu síly EURAMET cg-14","techniques":["Pomiar porównawczy wzorcowym urządzeniem momentu siły z użyciem obciążników i ramion momentu siły EURAMET cg-14"],"techniques_en":["Comparative measurement with a standard torque device using weights and torque arms, EURAMET cg-14"],"techniques_zh":["使用砝码和扭矩臂的标准扭矩装置比较测量 EURAMET cg-14"],"techniques_cs":["Porovnávací měření etalonovým zařízením momentu síly pomocí zatěžovacích těles a ramének momentu síly EURAMET cg-14"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nZakres:\nod 0,05 Nm do 12 Nm CMC 0,04 %\nod 1,5 Nm do 2000 Nm CMC 0,02 %\nPomiar porównawczy wzorcowym urządzeniem momentu siły z użyciem obciążników i ramion momentu siły EURAMET cg-14","reference":"ITS-04-11-S, ITS-09-11-LSP","norm_bases":["ITS-04-11-S","ITS-09-11-LSP"],"lab_section":"Laboratorium Průmyslová","lab_section_en":"Laboratory Průmyslová","lab_section_zh":"Průmyslová 实验室","lab_section_cs":"Laboratoř Průmyslová","lab_address":"Průmyslová 1428/10, 102 00 Praha 10, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu siły Wzorcowanie – moment siły Pomiar porównawczy wzorcowym urządzeniem momentu siły z użyciem obciążników i ramion momentu siły EURAMET cg-14 od 0,05 Nm do 12 Nm CMC 0,04 % od 1,5 Nm do 2000 Nm CMC 0,02 % Snímače rotační a statické,zařízení pro měření momentu síly Kalibrace – moment síly Porovnávací měření etalonovým zařízením momentu síly pomocí zatěžovacích těles a ramének momentu síly EURAMET cg-14 0,05 Nm až 12 Nm CMC 0,04 % 1,5 Nm až 2000 Nm CMC 0,02 % ITS-04-11-S, ITS-09-11-LSP Przetworniki obrotowe i statyczne, urzadzenia do pomiaru momentu sily Wzorcowanie – moment sily Pomiar porownawczy wzorcowym urzadzeniem momentu sily z uzyciem obciaznikow i ramion momentu sily EURAMET cg-14 od 0,05 Nm do 12 Nm CMC 0,04 % od 1,5 Nm do 2000 Nm CMC 0,02 % Snimace rotacni a staticke,zarizeni pro mereni momentu sily Kalibrace – moment sily Porovnavaci mereni etalonovym zarizenim momentu sily pomoci zatezovacich teles a ramenek momentu sily EURAMET cg-14 0,05 Nm az 12 Nm CMC 0,04 % 1,5 Nm az 2000 Nm CMC 0,02 % ITS-04-11-S, ITS-09-11-LSP","search_en":"Rotary and static transducers, devices for measuring torque Calibration – torque Comparative measurement with a standard torque device using weights and torque arms, EURAMET cg-14 0,05 Nm to 12 Nm CMC 0,04 % 1,5 Nm to 2000 Nm CMC 0,02 % ITS-04-11-S, ITS-09-11-LSP","search_zh":"旋转式和静态扭矩传感器、扭矩测量装置 校准 – 扭矩 使用砝码和扭矩臂的标准扭矩装置比较测量 EURAMET cg-14 0,05 Nm 至 12 Nm CMC 0,04 % 1,5 Nm 至 2000 Nm CMC 0,02 % ITS-04-11-S, ITS-09-11-LSP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e34fc9b417cf58da504379c6","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"2","test_object":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu obrotowego","test_object_en":"Rotary and static transducers, devices for measuring torque","test_object_zh":"旋转式和静态扭矩传感器、转矩测量装置","test_object_cs":"Snímače rotační a statické,zařízení pro měření krouticího momentu","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 500 Nm","cmc":"0,20 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 500 Nm","cmc":"0,20 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 500 Nm","cmc":"0,20 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 500 Nm","cmc":"0,20 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14","technique_en":"Direct measurement with a portable reference torque standard (torque transducer) EURAMET cg 14","technique_zh":"用便携式参考扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14","technique_cs":"Přímé měření přenosovým referenčním etalonem momentu síly (snímač momentu) EURAMET cg 14","techniques":["Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14"],"techniques_en":["Direct measurement with a portable reference torque standard (torque transducer) EURAMET cg 14"],"techniques_zh":["用便携式参考扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14"],"techniques_cs":["Přímé měření přenosovým referenčním etalonem momentu síly (snímač momentu) EURAMET cg 14"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nod 0,05 Nm do 500 Nm CMC 0,20 %\nBezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14","reference":"ITS-04-11-S, ITS-09-11-LSP","norm_bases":["ITS-04-11-S","ITS-09-11-LSP"],"lab_section":"Laboratorium Průmyslová","lab_section_en":"Laboratory Průmyslová","lab_section_zh":"Průmyslová 实验室","lab_section_cs":"Laboratoř Průmyslová","lab_address":"Průmyslová 1428/10, 102 00 Praha 10, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu obrotowego Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14 od 0,05 Nm do 500 Nm CMC 0,20 % Snímače rotační a statické,zařízení pro měření krouticího momentu Kalibrace – moment síly Přímé měření přenosovým referenčním etalonem momentu síly (snímač momentu) EURAMET cg 14 0,05 Nm až 500 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP Przetworniki obrotowe i statyczne, urzadzenia do pomiaru momentu obrotowego Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem odniesienia momentu sily (przetwornik momentu) EURAMET cg 14 od 0,05 Nm do 500 Nm CMC 0,20 % Snimace rotacni a staticke,zarizeni pro mereni krouticiho momentu Kalibrace – moment sily Prime mereni prenosovym referencnim etalonem momentu sily (snimac momentu) EURAMET cg 14 0,05 Nm az 500 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","search_en":"Rotary and static transducers, devices for measuring torque Calibration – torque Direct measurement with a portable reference torque standard (torque transducer) EURAMET cg 14 0,05 Nm to 500 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","search_zh":"旋转式和静态扭矩传感器、转矩测量装置 校准 – 扭矩 用便携式参考扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14 0,05 Nm 至 500 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b4636e5634d58b31f207b95","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"3","test_object":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu obrotowego","test_object_en":"Rotary and static transducers, devices for measuring torque","test_object_zh":"旋转式和静态扭矩传感器、转矩测量装置","test_object_cs":"Snímače rotační a statické, zařízení pro měření krouticího momentu","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,2 Nm do 3000 Nm","cmc":"0,20 %"}],"parameters_en":[{"name":"","range":"0,2 Nm to 3000 Nm","cmc":"0,20 %"}],"parameters_zh":[{"name":"","range":"0,2 Nm 至 3000 Nm","cmc":"0,20 %"}],"parameters_cs":[{"name":"","range":"0,2 Nm až 3000 Nm","cmc":"0,20 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14","technique_en":"Direct measurement with a reference portable torque standard (torque transducer) EURAMET cg 14","technique_zh":"用参考便携式扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14","technique_cs":"Přímé měření referenčním přenosovým etalonem momentu síly (snímač momentu) EURAMET cg 14","techniques":["Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14"],"techniques_en":["Direct measurement with a reference portable torque standard (torque transducer) EURAMET cg 14"],"techniques_zh":["用参考便携式扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14"],"techniques_cs":["Přímé měření referenčním přenosovým etalonem momentu síly (snímač momentu) EURAMET cg 14"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nod 0,2 Nm do 3000 Nm CMC 0,20 %\nBezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14","reference":"ITS-04-11-S, ITS-09-11-LSP","norm_bases":["ITS-04-11-S","ITS-09-11-LSP"],"lab_section":"Laboratorium CSW","lab_section_en":"Laboratory CSW","lab_section_zh":"CSW 实验室","lab_section_cs":"Laboratoř CSW","lab_address":"Rózyniec 83C, 59-706 Gromadka, Polsko","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu obrotowego Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14 od 0,2 Nm do 3000 Nm CMC 0,20 % Snímače rotační a statické, zařízení pro měření krouticího momentu Kalibrace – moment síly Přímé měření referenčním přenosovým etalonem momentu síly (snímač momentu) EURAMET cg 14 0,2 Nm až 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP Przetworniki obrotowe i statyczne, urzadzenia do pomiaru momentu obrotowego Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem odniesienia momentu sily (przetwornik momentu) EURAMET cg 14 od 0,2 Nm do 3000 Nm CMC 0,20 % Snimace rotacni a staticke, zarizeni pro mereni krouticiho momentu Kalibrace – moment sily Prime mereni referencnim prenosovym etalonem momentu sily (snimac momentu) EURAMET cg 14 0,2 Nm az 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","search_en":"Rotary and static transducers, devices for measuring torque Calibration – torque Direct measurement with a reference portable torque standard (torque transducer) EURAMET cg 14 0,2 Nm to 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","search_zh":"旋转式和静态扭矩传感器、转矩测量装置 校准 – 扭矩 用参考便携式扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14 0,2 Nm 至 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"03402ed200df2c1669ace755","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"3","test_object":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu obrotowego","test_object_en":"Rotary and static transducers, devices for measuring torque","test_object_zh":"旋转式和静态扭矩传感器、转矩测量装置","test_object_cs":"Snímače rotační a statické, zařízení pro měření krouticího momentu","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,2 Nm do 3000 Nm","cmc":"0,20 %"}],"parameters_en":[{"name":"","range":"0,2 Nm to 3000 Nm","cmc":"0,20 %"}],"parameters_zh":[{"name":"","range":"0,2 Nm 至 3000 Nm","cmc":"0,20 %"}],"parameters_cs":[{"name":"","range":"0,2 Nm až 3000 Nm","cmc":"0,20 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14","technique_en":"Direct measurement with a reference portable torque standard (torque transducer) EURAMET cg 14","technique_zh":"用参考便携式扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14","technique_cs":"Přímé měření referenčním přenosovým etalonem momentu síly (snímač momentu) EURAMET cg 14","techniques":["Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14"],"techniques_en":["Direct measurement with a reference portable torque standard (torque transducer) EURAMET cg 14"],"techniques_zh":["用参考便携式扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14"],"techniques_cs":["Přímé měření referenčním přenosovým etalonem momentu síly (snímač momentu) EURAMET cg 14"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nod 0,2 Nm do 3000 Nm CMC 0,20 %\nBezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14","reference":"ITS-04-11-S, ITS-09-11-LSP","norm_bases":["ITS-04-11-S","ITS-09-11-LSP"],"lab_section":"Laboratorium Chodov","lab_section_en":"Laboratory Chodov","lab_section_zh":"Chodov 实验室","lab_section_cs":"Laboratoř Chodov","lab_address":"V Parku 2336/22, 140 00 Praha 4, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przetworniki obrotowe i statyczne, urządzenia do pomiaru momentu obrotowego Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem odniesienia momentu siły (przetwornik momentu) EURAMET cg 14 od 0,2 Nm do 3000 Nm CMC 0,20 % Snímače rotační a statické, zařízení pro měření krouticího momentu Kalibrace – moment síly Přímé měření referenčním přenosovým etalonem momentu síly (snímač momentu) EURAMET cg 14 0,2 Nm až 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP Przetworniki obrotowe i statyczne, urzadzenia do pomiaru momentu obrotowego Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem odniesienia momentu sily (przetwornik momentu) EURAMET cg 14 od 0,2 Nm do 3000 Nm CMC 0,20 % Snimace rotacni a staticke, zarizeni pro mereni krouticiho momentu Kalibrace – moment sily Prime mereni referencnim prenosovym etalonem momentu sily (snimac momentu) EURAMET cg 14 0,2 Nm az 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","search_en":"Rotary and static transducers, devices for measuring torque Calibration – torque Direct measurement with a reference portable torque standard (torque transducer) EURAMET cg 14 0,2 Nm to 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","search_zh":"旋转式和静态扭矩传感器、转矩测量装置 校准 – 扭矩 用参考便携式扭矩标准器（扭矩传感器）直接测量 EURAMET cg 14 0,2 Nm 至 3000 Nm CMC 0,20 % ITS-04-11-S, ITS-09-11-LSP","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f373acdd9bc7789478c4902","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"4","test_object":"Urządzenia do dokręcania i systemy dokręcania","test_object_en":"Tightening devices and tightening systems","test_object_zh":"拧紧装置和拧紧系统","test_object_cs":"Utahovací přístroje a utahovací systémy","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"od 0,4 Nm do 2000 Nm","cmc":"0,50 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"0,4 Nm to 2000 Nm","cmc":"0,50 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"0,4 Nm 至 2000 Nm","cmc":"0,50 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"0,4 Nm až 2000 Nm","cmc":"0,50 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393","technique_en":"Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393","technique_zh":"用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393","technique_cs":"Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393","techniques":["Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393"],"techniques_en":["Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393"],"techniques_zh":["用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393"],"techniques_cs":["Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nZakres:\nod 0,05 Nm do 0,4 Nm CMC 0,60 %\nod 0,4 Nm do 2000 Nm CMC 0,50 %\nBezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393","reference":"ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","norm_bases":["ITS-01-11-U","ITS-02-11-V","ITS-03-11-VM","ITS-06-11-UC","ITS-07-11-VC","ITS-08-11-VMC"],"lab_section":"Laboratorium Průmyslová","lab_section_en":"Laboratory Průmyslová","lab_section_zh":"Průmyslová 实验室","lab_section_cs":"Laboratoř Průmyslová","lab_address":"Průmyslová 1428/10, 102 00 Praha 10, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia do dokręcania i systemy dokręcania Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393 od 0,05 Nm do 0,4 Nm CMC 0,60 % od 0,4 Nm do 2000 Nm CMC 0,50 % Utahovací přístroje a utahovací systémy Kalibrace – moment síly Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393 0,05 Nm až 0,4 Nm CMC 0,60 % 0,4 Nm až 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC Urzadzenia do dokrecania i systemy dokrecania Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem momentu sily (przetwornik momentu) EN ISO 6789-2, ISO 5393 od 0,05 Nm do 0,4 Nm CMC 0,60 % od 0,4 Nm do 2000 Nm CMC 0,50 % Utahovaci pristroje a utahovaci systemy Kalibrace – moment sily Prime mereni prenosovym etalonem momentu sily (snimac momentu) EN ISO 6789-2, ISO 5393 0,05 Nm az 0,4 Nm CMC 0,60 % 0,4 Nm az 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","search_en":"Tightening devices and tightening systems Calibration – torque Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393 0,05 Nm to 0,4 Nm CMC 0,60 % 0,4 Nm to 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","search_zh":"拧紧装置和拧紧系统 校准 – 扭矩 用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393 0,05 Nm 至 0,4 Nm CMC 0,60 % 0,4 Nm 至 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7fdb388e4a033acffff22cce","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"4","test_object":"Urządzenia do dokręcania i systemy dokręcania","test_object_en":"Tightening devices and tightening systems","test_object_zh":"拧紧装置和拧紧系统","test_object_cs":"Utahovací přístroje a utahovací systémy","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"od 0,4 Nm do 2000 Nm","cmc":"0,50 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"0,4 Nm to 2000 Nm","cmc":"0,50 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"0,4 Nm 至 2000 Nm","cmc":"0,50 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 0,4 Nm","cmc":"0,60 %"},{"name":"","range":"0,4 Nm až 2000 Nm","cmc":"0,50 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393","technique_en":"Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393","technique_zh":"用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393","technique_cs":"Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393","techniques":["Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393"],"techniques_en":["Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393"],"techniques_zh":["用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393"],"techniques_cs":["Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nZakres:\nod 0,05 Nm do 0,4 Nm CMC 0,60 %\nod 0,4 Nm do 2000 Nm CMC 0,50 %\nBezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393","reference":"ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","norm_bases":["ITS-01-11-U","ITS-02-11-V","ITS-03-11-VM","ITS-06-11-UC","ITS-07-11-VC","ITS-08-11-VMC"],"lab_section":"Laboratorium Chodov","lab_section_en":"Laboratory Chodov","lab_section_zh":"Chodov 实验室","lab_section_cs":"Laboratoř Chodov","lab_address":"V Parku 2336/22, 140 00 Praha 4, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia do dokręcania i systemy dokręcania Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393 od 0,05 Nm do 0,4 Nm CMC 0,60 % od 0,4 Nm do 2000 Nm CMC 0,50 % Utahovací přístroje a utahovací systémy Kalibrace – moment síly Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393 0,05 Nm až 0,4 Nm CMC 0,60 % 0,4 Nm až 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC Urzadzenia do dokrecania i systemy dokrecania Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem momentu sily (przetwornik momentu) EN ISO 6789-2, ISO 5393 od 0,05 Nm do 0,4 Nm CMC 0,60 % od 0,4 Nm do 2000 Nm CMC 0,50 % Utahovaci pristroje a utahovaci systemy Kalibrace – moment sily Prime mereni prenosovym etalonem momentu sily (snimac momentu) EN ISO 6789-2, ISO 5393 0,05 Nm az 0,4 Nm CMC 0,60 % 0,4 Nm az 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","search_en":"Tightening devices and tightening systems Calibration – torque Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393 0,05 Nm to 0,4 Nm CMC 0,60 % 0,4 Nm to 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","search_zh":"拧紧装置和拧紧系统 校准 – 扭矩 用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393 0,05 Nm 至 0,4 Nm CMC 0,60 % 0,4 Nm 至 2000 Nm CMC 0,50 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"676a2d910b76faf5533c0a8e","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"5","test_object":"Klucze dynamometryczne","test_object_en":"Torque wrenches","test_object_zh":"扭矩扳手","test_object_cs":"Momentové klíče","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"od 0,4 Nm do 2000 Nm","cmc":"0,94 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"0,4 Nm to 2000 Nm","cmc":"0,94 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"0,4 Nm 至 2000 Nm","cmc":"0,94 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"0,4 Nm až 2000 Nm","cmc":"0,94 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2","technique_en":"Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2","technique_zh":"用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2","technique_cs":"Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2","techniques":["Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2"],"techniques_en":["Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2"],"techniques_zh":["用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2"],"techniques_cs":["Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nZakres:\nod 0,05 Nm do 0,4 Nm CMC 1,0 %\nod 0,4 Nm do 2000 Nm CMC 0,94 %\nBezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2","reference":"ITS-05-11-K","norm_bases":["ITS-05-11-K"],"lab_section":"Laboratorium Průmyslová","lab_section_en":"Laboratory Průmyslová","lab_section_zh":"Průmyslová 实验室","lab_section_cs":"Laboratoř Průmyslová","lab_address":"Průmyslová 1428/10, 102 00 Praha 10, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Klucze dynamometryczne Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2 od 0,05 Nm do 0,4 Nm CMC 1,0 % od 0,4 Nm do 2000 Nm CMC 0,94 % Momentové klíče Kalibrace – moment síly Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2 0,05 Nm až 0,4 Nm CMC 1,0 % 0,4 Nm až 2000 Nm CMC 0,94 % ITS-05-11-K Klucze dynamometryczne Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem momentu sily (przetwornik momentu) EN ISO 6789-2 od 0,05 Nm do 0,4 Nm CMC 1,0 % od 0,4 Nm do 2000 Nm CMC 0,94 % Momentove klice Kalibrace – moment sily Prime mereni prenosovym etalonem momentu sily (snimac momentu) EN ISO 6789-2 0,05 Nm az 0,4 Nm CMC 1,0 % 0,4 Nm az 2000 Nm CMC 0,94 % ITS-05-11-K","search_en":"Torque wrenches Calibration – torque Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2 0,05 Nm to 0,4 Nm CMC 1,0 % 0,4 Nm to 2000 Nm CMC 0,94 % ITS-05-11-K","search_zh":"扭矩扳手 校准 – 扭矩 用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2 0,05 Nm 至 0,4 Nm CMC 1,0 % 0,4 Nm 至 2000 Nm CMC 0,94 % ITS-05-11-K","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e6c5aa9d34f3f884a98aa21","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"5","test_object":"Klucze dynamometryczne","test_object_en":"Torque wrenches","test_object_zh":"扭矩扳手","test_object_cs":"Momentové klíče","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"od 0,4 Nm do 2000 Nm","cmc":"0,94 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"0,4 Nm to 2000 Nm","cmc":"0,94 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"0,4 Nm 至 2000 Nm","cmc":"0,94 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 0,4 Nm","cmc":"1,0 %"},{"name":"","range":"0,4 Nm až 2000 Nm","cmc":"0,94 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2","technique_en":"Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2","technique_zh":"用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2","technique_cs":"Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2","techniques":["Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2"],"techniques_en":["Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2"],"techniques_zh":["用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2"],"techniques_cs":["Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nZakres:\nod 0,05 Nm do 0,4 Nm CMC 1,0 %\nod 0,4 Nm do 2000 Nm CMC 0,94 %\nBezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2","reference":"ITS-05-11-K","norm_bases":["ITS-05-11-K"],"lab_section":"Laboratorium Chodov","lab_section_en":"Laboratory Chodov","lab_section_zh":"Chodov 实验室","lab_section_cs":"Laboratoř Chodov","lab_address":"V Parku 2336/22, 140 00 Praha 4, Česká republika","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Klucze dynamometryczne Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2 od 0,05 Nm do 0,4 Nm CMC 1,0 % od 0,4 Nm do 2000 Nm CMC 0,94 % Momentové klíče Kalibrace – moment síly Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2 0,05 Nm až 0,4 Nm CMC 1,0 % 0,4 Nm až 2000 Nm CMC 0,94 % ITS-05-11-K Klucze dynamometryczne Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem momentu sily (przetwornik momentu) EN ISO 6789-2 od 0,05 Nm do 0,4 Nm CMC 1,0 % od 0,4 Nm do 2000 Nm CMC 0,94 % Momentove klice Kalibrace – moment sily Prime mereni prenosovym etalonem momentu sily (snimac momentu) EN ISO 6789-2 0,05 Nm az 0,4 Nm CMC 1,0 % 0,4 Nm az 2000 Nm CMC 0,94 % ITS-05-11-K","search_en":"Torque wrenches Calibration – torque Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2 0,05 Nm to 0,4 Nm CMC 1,0 % 0,4 Nm to 2000 Nm CMC 0,94 % ITS-05-11-K","search_zh":"扭矩扳手 校准 – 扭矩 用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2 0,05 Nm 至 0,4 Nm CMC 1,0 % 0,4 Nm 至 2000 Nm CMC 0,94 % ITS-05-11-K","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d7f494f52759e05326d4c58f","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"6","test_object":"Urządzenia do dokręcania i systemy dokręcania","test_object_en":"Tightening devices and tightening systems","test_object_zh":"拧紧装置和拧紧系统","test_object_cs":"Utahovací přístroje a utahovací systémy","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 2 Nm","cmc":"0,75 %"},{"name":"","range":"od 2 Nm do 2000 Nm","cmc":"0,50 %"},{"name":"","range":"od 2000 Nm do 10000 Nm","cmc":"2,0 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 2 Nm","cmc":"0,75 %"},{"name":"","range":"2 Nm to 2000 Nm","cmc":"0,50 %"},{"name":"","range":"2000 Nm to 10000 Nm","cmc":"2,0 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 2 Nm","cmc":"0,75 %"},{"name":"","range":"2 Nm 至 2000 Nm","cmc":"0,50 %"},{"name":"","range":"2000 Nm 至 10000 Nm","cmc":"2,0 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 2 Nm","cmc":"0,75 %"},{"name":"","range":"2 Nm až 2000 Nm","cmc":"0,50 %"},{"name":"","range":"2000 Nm až 10000 Nm","cmc":"2,0 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393","technique_en":"Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393","technique_zh":"用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393","technique_cs":"Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393","techniques":["Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393"],"techniques_en":["Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393"],"techniques_zh":["用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393"],"techniques_cs":["Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nZakres:\nod 0,05 Nm do 2 Nm CMC 0,75 %\nod 2 Nm do 2000 Nm CMC 0,50 %\nod 2000 Nm do 10000 Nm CMC 2,0 %\nBezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393","reference":"ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","norm_bases":["ITS-01-11-U","ITS-02-11-V","ITS-03-11-VM","ITS-06-11-UC","ITS-07-11-VC","ITS-08-11-VMC"],"lab_section":"Laboratorium CSW","lab_section_en":"Laboratory CSW","lab_section_zh":"CSW 实验室","lab_section_cs":"Laboratoř CSW","lab_address":"Rózyniec 83C, 59-706 Gromadka, Polsko","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia do dokręcania i systemy dokręcania Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2, ISO 5393 od 0,05 Nm do 2 Nm CMC 0,75 % od 2 Nm do 2000 Nm CMC 0,50 % od 2000 Nm do 10000 Nm CMC 2,0 % Utahovací přístroje a utahovací systémy Kalibrace – moment síly Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2, ISO 5393 0,05 Nm až 2 Nm CMC 0,75 % 2 Nm až 2000 Nm CMC 0,50 % 2000 Nm až 10000 Nm CMC 2,0 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC Urzadzenia do dokrecania i systemy dokrecania Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem momentu sily (przetwornik momentu) EN ISO 6789-2, ISO 5393 od 0,05 Nm do 2 Nm CMC 0,75 % od 2 Nm do 2000 Nm CMC 0,50 % od 2000 Nm do 10000 Nm CMC 2,0 % Utahovaci pristroje a utahovaci systemy Kalibrace – moment sily Prime mereni prenosovym etalonem momentu sily (snimac momentu) EN ISO 6789-2, ISO 5393 0,05 Nm az 2 Nm CMC 0,75 % 2 Nm az 2000 Nm CMC 0,50 % 2000 Nm az 10000 Nm CMC 2,0 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","search_en":"Tightening devices and tightening systems Calibration – torque Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2, ISO 5393 0,05 Nm to 2 Nm CMC 0,75 % 2 Nm to 2000 Nm CMC 0,50 % 2000 Nm to 10000 Nm CMC 2,0 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","search_zh":"拧紧装置和拧紧系统 校准 – 扭矩 用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2、ISO 5393 0,05 Nm 至 2 Nm CMC 0,75 % 2 Nm 至 2000 Nm CMC 0,50 % 2000 Nm 至 10000 Nm CMC 2,0 % ITS-01-11-U, ITS-02-11-V, ITS-03-11-VM, ITS-06-11-UC, ITS-07-11-VC, ITS-08-11-VMC","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f55ba3135a208f089e5bc39","lab_id":"6acfffe7ff06824761705e14","country":"CZ","accr_number":"2339","accr_body":"ČIA","row_label":"7","test_object":"Klucze dynamometryczne","test_object_en":"Torque wrenches","test_object_zh":"扭矩扳手","test_object_cs":"Momentové klíče","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 0,05 Nm do 2 Nm","cmc":"1,1 %"},{"name":"","range":"od 2 Nm do 2000 Nm","cmc":"0,94 %"}],"parameters_en":[{"name":"","range":"0,05 Nm to 2 Nm","cmc":"1,1 %"},{"name":"","range":"2 Nm to 2000 Nm","cmc":"0,94 %"}],"parameters_zh":[{"name":"","range":"0,05 Nm 至 2 Nm","cmc":"1,1 %"},{"name":"","range":"2 Nm 至 2000 Nm","cmc":"0,94 %"}],"parameters_cs":[{"name":"","range":"0,05 Nm až 2 Nm","cmc":"1,1 %"},{"name":"","range":"2 Nm až 2000 Nm","cmc":"0,94 %"}],"technique":"Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2","technique_en":"Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2","technique_zh":"用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2","technique_cs":"Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2","techniques":["Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2"],"techniques_en":["Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2"],"techniques_zh":["用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2"],"techniques_cs":["Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nZakres:\nod 0,05 Nm do 2 Nm CMC 1,1 %\nod 2 Nm do 2000 Nm CMC 0,94 %\nBezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2","reference":"ITS-05-11-K","norm_bases":["ITS-05-11-K"],"lab_section":"Laboratorium CSW","lab_section_en":"Laboratory CSW","lab_section_zh":"CSW 实验室","lab_section_cs":"Laboratoř CSW","lab_address":"Rózyniec 83C, 59-706 Gromadka, Polsko","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Klucze dynamometryczne Wzorcowanie – moment siły Bezpośredni pomiar przenośnym wzorcem momentu siły (przetwornik momentu) EN ISO 6789-2 od 0,05 Nm do 2 Nm CMC 1,1 % od 2 Nm do 2000 Nm CMC 0,94 % Momentové klíče Kalibrace – moment síly Přímé měření přenosovým etalonem momentu síly (snímač momentu) EN ISO 6789-2 0,05 Nm až 2 Nm CMC 1,1 % 2 Nm až 2000 Nm CMC 0,94 % ITS-05-11-K Klucze dynamometryczne Wzorcowanie – moment sily Bezposredni pomiar przenosnym wzorcem momentu sily (przetwornik momentu) EN ISO 6789-2 od 0,05 Nm do 2 Nm CMC 1,1 % od 2 Nm do 2000 Nm CMC 0,94 % Momentove klice Kalibrace – moment sily Prime mereni prenosovym etalonem momentu sily (snimac momentu) EN ISO 6789-2 0,05 Nm az 2 Nm CMC 1,1 % 2 Nm az 2000 Nm CMC 0,94 % ITS-05-11-K","search_en":"Torque wrenches Calibration – torque Direct measurement with a portable torque standard (torque transducer) EN ISO 6789-2 0,05 Nm to 2 Nm CMC 1,1 % 2 Nm to 2000 Nm CMC 0,94 % ITS-05-11-K","search_zh":"扭矩扳手 校准 – 扭矩 用便携式扭矩标准器（扭矩传感器）直接测量 EN ISO 6789-2 0,05 Nm 至 2 Nm CMC 1,1 % 2 Nm 至 2000 Nm CMC 0,94 % ITS-05-11-K","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}