{"lab":{"_id":"6ade8b36ff06824761708117","accr_number":"2329","country":"CZ","accr_body":"ČIA","address":"Vídeňská 104, 252 50 Vestec","categories":["metrology"],"city":"Vestec","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4936975,49.9853063]},"map_coord":[49.9853063,14.4936975],"map_geo":"cai-mapa","methods_count":2,"name":"SAFINA, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie termoelektrycznych czujników temperatury z metali szlachetnych i czystych.","search_text":"safina, a.s. vídeňská 104, 252 50 vestec 2329","source_page_url":"https://www.cai.cz/?subjekt=2329-safina-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"30-01-2028","website":"www.safina.cz","certificate_date":"30.01.2023","certificate_no":"38/2023","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie termoelektrycznych czujników temperatury z metali szlachetnych i czystych.","en":"Calibration of thermoelectric temperature sensors made of precious and pure metals.","zh":"贵金属和纯金属热电式温度传感器的校准。","cs":"Kalibrace termoelektrických snímačů teploty z drahých a čistých kovů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Dział produkcji termopar – laboratorium wzorcujące","lab_division_cs":"Oddělení produkce termočlánků – kalibrační laboratoř","lab_division_en":"Thermocouple Production Department – Calibration Laboratory","lab_division_zh":"热电偶生产部 – 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"f589153a9e7b734bf12dbcba743bfcbbbda8f5ee75a846223e031f1152123090","source_pdf_url":"https://www.cai.cz/OA/pdf/P38_2023_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P38_2023_EN.pdf"},"methods":[{"_id":"6a93c54a93146fcfd0012664","lab_id":"6ade8b36ff06824761708117","country":"CZ","accr_number":"2329","accr_body":"ČIA","row_label":"1","test_object":"Termoelektryczne czujniki temperatury z metali czystych i szlachetnych","test_object_en":"Thermoelectric temperature sensors made of pure and precious metals","test_object_zh":"纯金属和贵金属热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty z čistých a ušlechtilých kovů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Zn","range":"419,527 °C","cmc":"0,3 °C"},{"name":"Al","range":"660,323 °C","cmc":"0,3 °C"},{"name":"Ag","range":"961,78 °C","cmc":"0,5 °C"},{"name":"Au","range":"1064,18 °C","cmc":"0,7 °C"},{"name":"Cu","range":"1084,62 °C","cmc":"0,5 °C"},{"name":"Pd","range":"1553,5 °C","cmc":"1,4 °C"}],"parameters_en":[{"name":"Zn","range":"419,527 °C","cmc":"0,3 °C"},{"name":"Al","range":"660,323 °C","cmc":"0,3 °C"},{"name":"Ag","range":"961,78 °C","cmc":"0,5 °C"},{"name":"Au","range":"1064,18 °C","cmc":"0,7 °C"},{"name":"Cu","range":"1084,62 °C","cmc":"0,5 °C"},{"name":"Pd","range":"1553,5 °C","cmc":"1,4 °C"}],"parameters_zh":[{"name":"锌 Zn","range":"419,527 °C","cmc":"0,3 °C"},{"name":"铝 Al","range":"660,323 °C","cmc":"0,3 °C"},{"name":"银 Ag","range":"961,78 °C","cmc":"0,5 °C"},{"name":"金 Au","range":"1064,18 °C","cmc":"0,7 °C"},{"name":"铜 Cu","range":"1084,62 °C","cmc":"0,5 °C"},{"name":"钯 Pd","range":"1553,5 °C","cmc":"1,4 °C"}],"parameters_cs":[{"name":"Zn","range":"419,527 °C","cmc":"0,3 °C"},{"name":"Al","range":"660,323 °C","cmc":"0,3 °C"},{"name":"Ag","range":"961,78 °C","cmc":"0,5 °C"},{"name":"Au","range":"1064,18 °C","cmc":"0,7 °C"},{"name":"Cu","range":"1084,62 °C","cmc":"0,5 °C"},{"name":"Pd","range":"1553,5 °C","cmc":"1,4 °C"}],"technique":"Punkty stałe","technique_en":"Fixed points","technique_zh":"固定点","technique_cs":"Pevné body","techniques":["Punkty stałe"],"techniques_en":["Fixed points"],"techniques_zh":["固定点"],"techniques_cs":["Pevné body"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nZn 419,527 °C CMC 0,3 °C\nAl 660,323 °C CMC 0,3 °C\nAg 961,78 °C CMC 0,5 °C\nAu 1064,18 °C CMC 0,7 °C\nCu 1084,62 °C CMC 0,5 °C\nPd 1553,5 °C CMC 1,4 °C\nPunkty stałe","reference":"PP.31901.070","norm_bases":["PP.31901.070"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury z metali czystych i szlachetnych Wzorcowanie – temperatura Punkty stałe Zn 419,527 °C CMC 0,3 °C Al 660,323 °C CMC 0,3 °C Ag 961,78 °C CMC 0,5 °C Au 1064,18 °C CMC 0,7 °C Cu 1084,62 °C CMC 0,5 °C Pd 1553,5 °C CMC 1,4 °C Termoelektrické snímače teploty z čistých a ušlechtilých kovů Kalibrace – teplota Pevné body Zn 419,527 °C CMC 0,3 °C Al 660,323 °C CMC 0,3 °C Ag 961,78 °C CMC 0,5 °C Au 1064,18 °C CMC 0,7 °C Cu 1084,62 °C CMC 0,5 °C Pd 1553,5 °C CMC 1,4 °C PP.31901.070 Termoelektryczne czujniki temperatury z metali czystych i szlachetnych Wzorcowanie – temperatura Punkty stale Zn 419,527 °C CMC 0,3 °C Al 660,323 °C CMC 0,3 °C Ag 961,78 °C CMC 0,5 °C Au 1064,18 °C CMC 0,7 °C Cu 1084,62 °C CMC 0,5 °C Pd 1553,5 °C CMC 1,4 °C Termoelektricke snimace teploty z cistych a uslechtilych kovu Kalibrace – teplota Pevne body Zn 419,527 °C CMC 0,3 °C Al 660,323 °C CMC 0,3 °C Ag 961,78 °C CMC 0,5 °C Au 1064,18 °C CMC 0,7 °C Cu 1084,62 °C CMC 0,5 °C Pd 1553,5 °C CMC 1,4 °C PP.31901.070","search_en":"Thermoelectric temperature sensors made of pure and precious metals Calibration – temperature Fixed points Zn 419,527 °C CMC 0,3 °C Al 660,323 °C CMC 0,3 °C Ag 961,78 °C CMC 0,5 °C Au 1064,18 °C CMC 0,7 °C Cu 1084,62 °C CMC 0,5 °C Pd 1553,5 °C CMC 1,4 °C PP.31901.070","search_zh":"纯金属和贵金属热电式温度传感器 校准 – 温度 固定点 锌 Zn 419,527 °C CMC 0,3 °C 铝 Al 660,323 °C CMC 0,3 °C 银 Ag 961,78 °C CMC 0,5 °C 金 Au 1064,18 °C CMC 0,7 °C 铜 Cu 1084,62 °C CMC 0,5 °C 钯 Pd 1553,5 °C CMC 1,4 °C PP.31901.070","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"918d0ccac3c32bc59fadd2e9","lab_id":"6ade8b36ff06824761708117","country":"CZ","accr_number":"2329","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury z metali czystych i szlachetnych","test_object_en":"Thermoelectric temperature sensors made of pure and precious metals","test_object_zh":"纯金属和贵金属热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty z čistých a ušlechtilých kovů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 230 °C do 420 °C","cmc":"0,5 °C"},{"name":"","range":"od 420 °C do 660 °C","cmc":"0,9 °C"},{"name":"","range":"od 660 °C do 1085 °C","cmc":"1,2 °C"},{"name":"","range":"od 1085 °C do 1100 °C","cmc":"1,4 °C"},{"name":"","range":"od 1100 °C do 1400 °C","cmc":"2,2 °C"},{"name":"","range":"od 1400 °C do 1554 °C","cmc":"2,7 °C"}],"parameters_en":[{"name":"","range":"230 °C to 420 °C","cmc":"0,5 °C"},{"name":"","range":"420 °C to 660 °C","cmc":"0,9 °C"},{"name":"","range":"660 °C to 1085 °C","cmc":"1,2 °C"},{"name":"","range":"1085 °C to 1100 °C","cmc":"1,4 °C"},{"name":"","range":"1100 °C to 1400 °C","cmc":"2,2 °C"},{"name":"","range":"1400 °C to 1554 °C","cmc":"2,7 °C"}],"parameters_zh":[{"name":"","range":"230 °C 至 420 °C","cmc":"0,5 °C"},{"name":"","range":"420 °C 至 660 °C","cmc":"0,9 °C"},{"name":"","range":"660 °C 至 1085 °C","cmc":"1,2 °C"},{"name":"","range":"1085 °C 至 1100 °C","cmc":"1,4 °C"},{"name":"","range":"1100 °C 至 1400 °C","cmc":"2,2 °C"},{"name":"","range":"1400 °C 至 1554 °C","cmc":"2,7 °C"}],"parameters_cs":[{"name":"","range":"230 °C až 420 °C","cmc":"0,5 °C"},{"name":"","range":"420 °C až 660 °C","cmc":"0,9 °C"},{"name":"","range":"660 °C až 1085 °C","cmc":"1,2 °C"},{"name":"","range":"1085 °C až 1100 °C","cmc":"1,4 °C"},{"name":"","range":"1100 °C až 1400 °C","cmc":"2,2 °C"},{"name":"","range":"1400 °C až 1554 °C","cmc":"2,7 °C"}],"technique":"Porównanie z wzorcowym termoelektrycznym czujnikiem temperatury w piecu poziomym","technique_en":"Comparison with a reference thermoelectric temperature sensor in a horizontal furnace","technique_zh":"在水平炉中与标准热电式温度传感器比较","technique_cs":"Porovnání s etalonovým termoelektrickým snímačem teploty v horizontální peci","techniques":["Porównanie z wzorcowym termoelektrycznym czujnikiem temperatury w piecu poziomym"],"techniques_en":["Comparison with a reference thermoelectric temperature sensor in a horizontal furnace"],"techniques_zh":["在水平炉中与标准热电式温度传感器比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým snímačem teploty v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 230 °C do 420 °C CMC 0,5 °C\nod 420 °C do 660 °C CMC 0,9 °C\nod 660 °C do 1085 °C CMC 1,2 °C\nod 1085 °C do 1100 °C CMC 1,4 °C\nod 1100 °C do 1400 °C CMC 2,2 °C\nod 1400 °C do 1554 °C CMC 2,7 °C\nPorównanie z wzorcowym termoelektrycznym czujnikiem temperatury w piecu poziomym","reference":"PP.31901.071","norm_bases":["PP.31901.071"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury z metali czystych i szlachetnych Wzorcowanie – temperatura Porównanie z wzorcowym termoelektrycznym czujnikiem temperatury w piecu poziomym od 230 °C do 420 °C CMC 0,5 °C od 420 °C do 660 °C CMC 0,9 °C od 660 °C do 1085 °C CMC 1,2 °C od 1085 °C do 1100 °C CMC 1,4 °C od 1100 °C do 1400 °C CMC 2,2 °C od 1400 °C do 1554 °C CMC 2,7 °C Termoelektrické snímače teploty z čistých a ušlechtilých kovů Kalibrace – teplota Porovnání s etalonovým termoelektrickým snímačem teploty v horizontální peci 230 °C až 420 °C CMC 0,5 °C 420 °C až 660 °C CMC 0,9 °C 660 °C až 1085 °C CMC 1,2 °C 1085 °C až 1100 °C CMC 1,4 °C 1100 °C až 1400 °C CMC 2,2 °C 1400 °C až 1554 °C CMC 2,7 °C PP.31901.071 Termoelektryczne czujniki temperatury z metali czystych i szlachetnych Wzorcowanie – temperatura Porownanie z wzorcowym termoelektrycznym czujnikiem temperatury w piecu poziomym od 230 °C do 420 °C CMC 0,5 °C od 420 °C do 660 °C CMC 0,9 °C od 660 °C do 1085 °C CMC 1,2 °C od 1085 °C do 1100 °C CMC 1,4 °C od 1100 °C do 1400 °C CMC 2,2 °C od 1400 °C do 1554 °C CMC 2,7 °C Termoelektricke snimace teploty z cistych a uslechtilych kovu Kalibrace – teplota Porovnani s etalonovym termoelektrickym snimacem teploty v horizontalni peci 230 °C az 420 °C CMC 0,5 °C 420 °C az 660 °C CMC 0,9 °C 660 °C az 1085 °C CMC 1,2 °C 1085 °C az 1100 °C CMC 1,4 °C 1100 °C az 1400 °C CMC 2,2 °C 1400 °C az 1554 °C CMC 2,7 °C PP.31901.071","search_en":"Thermoelectric temperature sensors made of pure and precious metals Calibration – temperature Comparison with a reference thermoelectric temperature sensor in a horizontal furnace 230 °C to 420 °C CMC 0,5 °C 420 °C to 660 °C CMC 0,9 °C 660 °C to 1085 °C CMC 1,2 °C 1085 °C to 1100 °C CMC 1,4 °C 1100 °C to 1400 °C CMC 2,2 °C 1400 °C to 1554 °C CMC 2,7 °C PP.31901.071","search_zh":"纯金属和贵金属热电式温度传感器 校准 – 温度 在水平炉中与标准热电式温度传感器比较 230 °C 至 420 °C CMC 0,5 °C 420 °C 至 660 °C CMC 0,9 °C 660 °C 至 1085 °C CMC 1,2 °C 1085 °C 至 1100 °C CMC 1,4 °C 1100 °C 至 1400 °C CMC 2,2 °C 1400 °C 至 1554 °C CMC 2,7 °C PP.31901.071","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}