{"lab":{"_id":"6ade8b35ff06824761708114","accr_number":"2319","country":"CZ","accr_body":"ČIA","address":"Železárenská 1958, 272 01 Kladno 1","categories":["metrology"],"city":"Kladno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.1066738,50.1510075]},"map_coord":[50.1510075,14.1066738],"map_geo":"nominatim-street","methods_count":2,"name":"Technické služby ochrany ovzduší Praha a.s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie pomiarów emisji.","search_text":"technické služby ochrany ovzduší praha a.s. železárenská 1958, 272 01 kladno 1 2319","source_page_url":"https://www.cai.cz/?subjekt=2319-technicke-sluzby-ochrany-ovzdusi-praha-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"11-08-2027","website":"www.teso.cz","certificate_date":"28.02.2025","certificate_no":"91/2025","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie pomiarów emisji.","en":"Calibration in the field of emission measurement.","zh":"排放测量领域的校准。","cs":"Kalibrace v oboru měření emisí."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące emisji","lab_division_cs":"Kalibrační laboratoř emisí","lab_division_en":"Emission Calibration Laboratory","lab_division_zh":"排放校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"fbaa5fe15e9dd0896cf366b2cc09693bfab28cf08f01c11cbee75d18397f1fc9","source_pdf_url":"https://www.cai.cz/OA/pdf/P91_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"f1a4a0bb6c963ce54077807a","lab_id":"6ade8b35ff06824761708114","country":"CZ","accr_number":"2319","accr_body":"ČIA","row_label":"1","test_object":"Stężenie składników gazowych","test_object_en":"Concentration of gaseous components","test_object_zh":"气态组分浓度","test_object_cs":"Koncentrace plynných složek","methodology":"Wzorcowanie – emisje","methodology_en":"Calibration – emissions","methodology_zh":"校准 – 排放","methodology_cs":"Kalibrace – emise","parameters":[{"name":"NO","range":"od 0 µmol/mol do 6 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"NO","range":"od 6 µmol/mol do 3000 µmol/mol","cmc":"0,50 %"},{"name":"CO","range":"od 0 µmol/mol do 42 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"CO","range":"od 42 µmol/mol do 8000 µmol/mol","cmc":"0,28 %"},{"name":"SO₂","range":"od 0 µmol/mol do 5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"SO₂","range":"od 5 µmol/mol do 2000 µmol/mol","cmc":"0,54 %"},{"name":"C₃H₈","range":"od 0 µmol/mol do 11 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"C₃H₈","range":"od 11 µmol/mol do 5000 µmol/mol","cmc":"0,42 %"},{"name":"CH₄","range":"od 0 µmol/mol do 10 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"CH₄","range":"od 10 µmol/mol do 40000 µmol/mol","cmc":"0,46 %"},{"name":"NH₃","range":"od 0 µmol/mol do 6 µmol/mol","cmc":"0,012 µmol/mol"},{"name":"NH₃","range":"od 6 µmol/mol do 2000 µmol/mol","cmc":"2,00 %"},{"name":"N₂O","range":"od 0 µmol/mol do 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"N₂O","range":"od 6 µmol/mol do 2000 µmol/mol","cmc":"2,00 %"},{"name":"NO₂","range":"od 0 µmol/mol do 1,5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"NO₂","range":"od 1,5 µmol/mol do 2000 µmol/mol","cmc":"2,00 %"},{"name":"O₂","range":"od 0 mol/mol do 0,002 mol/mol","cmc":"0,00001 mol/mol"},{"name":"O₂","range":"od 0,002 mol/mol do 0,24 mol/mol","cmc":"0,54 %"},{"name":"CO₂","range":"od 0 mol/mol do 0,24 mol/mol","cmc":"0,00001 mol/mol"},{"name":"CO₂","range":"od 0,002 mol/mol do 0,24 mol/mol","cmc":"0,54 %"}],"parameters_en":[{"name":"NO","range":"0 µmol/mol to 6 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"NO","range":"6 µmol/mol to 3000 µmol/mol","cmc":"0,50 %"},{"name":"CO","range":"0 µmol/mol to 42 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"CO","range":"42 µmol/mol to 8000 µmol/mol","cmc":"0,28 %"},{"name":"SO₂","range":"0 µmol/mol to 5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"SO₂","range":"5 µmol/mol to 2000 µmol/mol","cmc":"0,54 %"},{"name":"C₃H₈","range":"0 µmol/mol to 11 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"C₃H₈","range":"11 µmol/mol to 5000 µmol/mol","cmc":"0,42 %"},{"name":"CH₄","range":"0 µmol/mol to 10 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"CH₄","range":"10 µmol/mol to 40000 µmol/mol","cmc":"0,46 %"},{"name":"NH₃","range":"0 µmol/mol to 6 µmol/mol","cmc":"0,012 µmol/mol"},{"name":"NH₃","range":"6 µmol/mol to 2000 µmol/mol","cmc":"2,00 %"},{"name":"N₂O","range":"0 µmol/mol to 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"N₂O","range":"6 µmol/mol to 2000 µmol/mol","cmc":"2,00 %"},{"name":"NO₂","range":"0 µmol/mol to 1,5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"NO₂","range":"1,5 µmol/mol to 2000 µmol/mol","cmc":"2,00 %"},{"name":"O₂","range":"0 mol/mol to 0,002 mol/mol","cmc":"0,00001 mol/mol"},{"name":"O₂","range":"0,002 mol/mol to 0,24 mol/mol","cmc":"0,54 %"},{"name":"CO₂","range":"0 mol/mol to 0,24 mol/mol","cmc":"0,00001 mol/mol"},{"name":"CO₂","range":"0,002 mol/mol to 0,24 mol/mol","cmc":"0,54 %"}],"parameters_zh":[{"name":"一氧化氮 NO","range":"0 µmol/mol 至 6 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"一氧化氮 NO","range":"6 µmol/mol 至 3000 µmol/mol","cmc":"0,50 %"},{"name":"一氧化碳 CO","range":"0 µmol/mol 至 42 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"一氧化碳 CO","range":"42 µmol/mol 至 8000 µmol/mol","cmc":"0,28 %"},{"name":"二氧化硫 SO₂","range":"0 µmol/mol 至 5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"二氧化硫 SO₂","range":"5 µmol/mol 至 2000 µmol/mol","cmc":"0,54 %"},{"name":"丙烷 C₃H₈","range":"0 µmol/mol 至 11 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"丙烷 C₃H₈","range":"11 µmol/mol 至 5000 µmol/mol","cmc":"0,42 %"},{"name":"甲烷 CH₄","range":"0 µmol/mol 至 10 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"甲烷 CH₄","range":"10 µmol/mol 至 40000 µmol/mol","cmc":"0,46 %"},{"name":"氨 NH₃","range":"0 µmol/mol 至 6 µmol/mol","cmc":"0,012 µmol/mol"},{"name":"氨 NH₃","range":"6 µmol/mol 至 2000 µmol/mol","cmc":"2,00 %"},{"name":"一氧化二氮 N₂O","range":"0 µmol/mol 至 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"一氧化二氮 N₂O","range":"6 µmol/mol 至 2000 µmol/mol","cmc":"2,00 %"},{"name":"二氧化氮 NO₂","range":"0 µmol/mol 至 1,5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"二氧化氮 NO₂","range":"1,5 µmol/mol 至 2000 µmol/mol","cmc":"2,00 %"},{"name":"氧 O₂","range":"0 mol/mol 至 0,002 mol/mol","cmc":"0,00001 mol/mol"},{"name":"氧 O₂","range":"0,002 mol/mol 至 0,24 mol/mol","cmc":"0,54 %"},{"name":"二氧化碳 CO₂","range":"0 mol/mol 至 0,24 mol/mol","cmc":"0,00001 mol/mol"},{"name":"二氧化碳 CO₂","range":"0,002 mol/mol 至 0,24 mol/mol","cmc":"0,54 %"}],"parameters_cs":[{"name":"NO","range":"0 µmol/mol až 6 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"NO","range":"6 µmol/mol až 3000 µmol/mol","cmc":"0,50 %"},{"name":"CO","range":"0 µmol/mol až 42 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"CO","range":"42 µmol/mol až 8000 µmol/mol","cmc":"0,28 %"},{"name":"SO₂","range":"0 µmol/mol až 5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"SO₂","range":"5 µmol/mol až 2000 µmol/mol","cmc":"0,54 %"},{"name":"C₃H₈","range":"0 µmol/mol až 11 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"C₃H₈","range":"11 µmol/mol až 5000 µmol/mol","cmc":"0,42 %"},{"name":"CH₄","range":"0 µmol/mol až 10 µmol/mol","cmc":"0,05 µmol/mol"},{"name":"CH₄","range":"10 µmol/mol až 40000 µmol/mol","cmc":"0,46 %"},{"name":"NH₃","range":"0 µmol/mol až 6 µmol/mol","cmc":"0,012 µmol/mol"},{"name":"NH₃","range":"6 µmol/mol až 2000 µmol/mol","cmc":"2,00 %"},{"name":"N₂O","range":"0 µmol/mol až 6 µmol/mol","cmc":"0,12 µmol/mol"},{"name":"N₂O","range":"6 µmol/mol až 2000 µmol/mol","cmc":"2,00 %"},{"name":"NO₂","range":"0 µmol/mol až 1,5 µmol/mol","cmc":"0,03 µmol/mol"},{"name":"NO₂","range":"1,5 µmol/mol až 2000 µmol/mol","cmc":"2,00 %"},{"name":"O₂","range":"0 mol/mol až 0,002 mol/mol","cmc":"0,00001 mol/mol"},{"name":"O₂","range":"0,002 mol/mol až 0,24 mol/mol","cmc":"0,54 %"},{"name":"CO₂","range":"0 mol/mol až 0,24 mol/mol","cmc":"0,00001 mol/mol"},{"name":"CO₂","range":"0,002 mol/mol až 0,24 mol/mol","cmc":"0,54 %"}],"technique":"Porównanie z wzorcem gazowym przygotowanym w kalibratorze w objętościowo określonej mieszaninie RM z gazem obojętnym","technique_en":"Comparison with a gas standard prepared in a calibrator in a volumetrically defined mixture of RM with inert gas","technique_zh":"与在校准器中由标准物质与惰性气体按体积配制的气体标准比较","technique_cs":"Porovnání s plynným standardem připraveným v kalibrátoru v objemově definované směsi RM s inertním plynem","techniques":["Porównanie z wzorcem gazowym przygotowanym w kalibratorze w objętościowo określonej mieszaninie RM z gazem obojętnym"],"techniques_en":["Comparison with a gas standard prepared in a calibrator in a volumetrically defined mixture of RM with inert gas"],"techniques_zh":["与在校准器中由标准物质与惰性气体按体积配制的气体标准比较"],"techniques_cs":["Porovnání s plynným standardem připraveným v kalibrátoru v objemově definované směsi RM s inertním plynem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – emisje\nZakres:\nNO od 0 µmol/mol do 6 µmol/mol CMC 0,03 µmol/mol\nNO od 6 µmol/mol do 3000 µmol/mol CMC 0,50 %\nCO od 0 µmol/mol do 42 µmol/mol CMC 0,12 µmol/mol\nCO od 42 µmol/mol do 8000 µmol/mol CMC 0,28 %\nSO₂ od 0 µmol/mol do 5 µmol/mol CMC 0,03 µmol/mol\nSO₂ od 5 µmol/mol do 2000 µmol/mol CMC 0,54 %\nC₃H₈ od 0 µmol/mol do 11 µmol/mol CMC 0,05 µmol/mol\nC₃H₈ od 11 µmol/mol do 5000 µmol/mol CMC 0,42 %\nCH₄ od 0 µmol/mol do 10 µmol/mol CMC 0,05 µmol/mol\nCH₄ od 10 µmol/mol do 40000 µmol/mol CMC 0,46 %\nNH₃ od 0 µmol/mol do 6 µmol/mol CMC 0,012 µmol/mol\nNH₃ od 6 µmol/mol do 2000 µmol/mol CMC 2,00 %\nN₂O od 0 µmol/mol do 6 µmol/mol CMC 0,12 µmol/mol\nN₂O od 6 µmol/mol do 2000 µmol/mol CMC 2,00 %\nNO₂ od 0 µmol/mol do 1,5 µmol/mol CMC 0,03 µmol/mol\nNO₂ od 1,5 µmol/mol do 2000 µmol/mol CMC 2,00 %\nO₂ od 0 mol/mol do 0,002 mol/mol CMC 0,00001 mol/mol\nO₂ od 0,002 mol/mol do 0,24 mol/mol CMC 0,54 %\nCO₂ od 0 mol/mol do 0,24 mol/mol CMC 0,00001 mol/mol\nCO₂ od 0,002 mol/mol do 0,24 mol/mol CMC 0,54 %\nPorównanie z wzorcem gazowym przygotowanym w kalibratorze w objętościowo określonej mieszaninie RM z gazem obojętnym","reference":"IP 101-03 (EN ISO 9169; ISO 11095)","norm_bases":["IP 101-03","EN ISO 9169","ISO 11095"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: emisje","regulatory_area_en":"CMC for the field of measured quantity: Emissions","regulatory_area_zh":"被测量领域的CMC：排放","regulatory_area_cs":"CMC pro obor měřené veličiny: Emise","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stężenie składników gazowych Wzorcowanie – emisje Porównanie z wzorcem gazowym przygotowanym w kalibratorze w objętościowo określonej mieszaninie RM z gazem obojętnym NO od 0 µmol/mol do 6 µmol/mol CMC 0,03 µmol/mol NO od 6 µmol/mol do 3000 µmol/mol CMC 0,50 % CO od 0 µmol/mol do 42 µmol/mol CMC 0,12 µmol/mol CO od 42 µmol/mol do 8000 µmol/mol CMC 0,28 % SO₂ od 0 µmol/mol do 5 µmol/mol CMC 0,03 µmol/mol SO₂ od 5 µmol/mol do 2000 µmol/mol CMC 0,54 % C₃H₈ od 0 µmol/mol do 11 µmol/mol CMC 0,05 µmol/mol C₃H₈ od 11 µmol/mol do 5000 µmol/mol CMC 0,42 % CH₄ od 0 µmol/mol do 10 µmol/mol CMC 0,05 µmol/mol CH₄ od 10 µmol/mol do 40000 µmol/mol CMC 0,46 % NH₃ od 0 µmol/mol do 6 µmol/mol CMC 0,012 µmol/mol NH₃ od 6 µmol/mol do 2000 µmol/mol CMC 2,00 % N₂O od 0 µmol/mol do 6 µmol/mol CMC 0,12 µmol/mol N₂O od 6 µmol/mol do 2000 µmol/mol CMC 2,00 % NO₂ od 0 µmol/mol do 1,5 µmol/mol CMC 0,03 µmol/mol NO₂ od 1,5 µmol/mol do 2000 µmol/mol CMC 2,00 % O₂ od 0 mol/mol do 0,002 mol/mol CMC 0,00001 mol/mol O₂ od 0,002 mol/mol do 0,24 mol/mol CMC 0,54 % CO₂ od 0 mol/mol do 0,24 mol/mol CMC 0,00001 mol/mol CO₂ od 0,002 mol/mol do 0,24 mol/mol CMC 0,54 % Koncentrace plynných složek Kalibrace – emise Porovnání s plynným standardem připraveným v kalibrátoru v objemově definované směsi RM s inertním plynem NO 0 µmol/mol až 6 µmol/mol CMC 0,03 µmol/mol NO 6 µmol/mol až 3000 µmol/mol CMC 0,50 % CO 0 µmol/mol až 42 µmol/mol CMC 0,12 µmol/mol CO 42 µmol/mol až 8000 µmol/mol CMC 0,28 % SO₂ 0 µmol/mol až 5 µmol/mol CMC 0,03 µmol/mol SO₂ 5 µmol/mol až 2000 µmol/mol CMC 0,54 % C₃H₈ 0 µmol/mol až 11 µmol/mol CMC 0,05 µmol/mol C₃H₈ 11 µmol/mol až 5000 µmol/mol CMC 0,42 % CH₄ 0 µmol/mol až 10 µmol/mol CMC 0,05 µmol/mol CH₄ 10 µmol/mol až 40000 µmol/mol CMC 0,46 % NH₃ 0 µmol/mol až 6 µmol/mol CMC 0,012 µmol/mol NH₃ 6 µmol/mol až 2000 µmol/mol CMC 2,00 % N₂O 0 µmol/mol až 6 µmol/mol CMC 0,12 µmol/mol N₂O 6 µmol/mol až 2000 µmol/mol CMC 2,00 % NO₂ 0 µmol/mol až 1,5 µmol/mol CMC 0,03 µmol/mol NO₂ 1,5 µmol/mol až 2000 µmol/mol CMC 2,00 % O₂ 0 mol/mol až 0,002 mol/mol CMC 0,00001 mol/mol O₂ 0,002 mol/mol až 0,24 mol/mol CMC 0,54 % CO₂ 0 mol/mol až 0,24 mol/mol CMC 0,00001 mol/mol CO₂ 0,002 mol/mol až 0,24 mol/mol CMC 0,54 % IP 101-03 (EN ISO 9169; ISO 11095) Stezenie skladnikow gazowych Wzorcowanie – emisje Porownanie z wzorcem gazowym przygotowanym w kalibratorze w objetosciowo okreslonej mieszaninie RM z gazem obojetnym NO od 0 µmol/mol do 6 µmol/mol CMC 0,03 µmol/mol NO od 6 µmol/mol do 3000 µmol/mol CMC 0,50 % CO od 0 µmol/mol do 42 µmol/mol CMC 0,12 µmol/mol CO od 42 µmol/mol do 8000 µmol/mol CMC 0,28 % SO₂ od 0 µmol/mol do 5 µmol/mol CMC 0,03 µmol/mol SO₂ od 5 µmol/mol do 2000 µmol/mol CMC 0,54 % C₃H₈ od 0 µmol/mol do 11 µmol/mol CMC 0,05 µmol/mol C₃H₈ od 11 µmol/mol do 5000 µmol/mol CMC 0,42 % CH₄ od 0 µmol/mol do 10 µmol/mol CMC 0,05 µmol/mol CH₄ od 10 µmol/mol do 40000 µmol/mol CMC 0,46 % NH₃ od 0 µmol/mol do 6 µmol/mol CMC 0,012 µmol/mol NH₃ od 6 µmol/mol do 2000 µmol/mol CMC 2,00 % N₂O od 0 µmol/mol do 6 µmol/mol CMC 0,12 µmol/mol N₂O od 6 µmol/mol do 2000 µmol/mol CMC 2,00 % NO₂ od 0 µmol/mol do 1,5 µmol/mol CMC 0,03 µmol/mol NO₂ od 1,5 µmol/mol do 2000 µmol/mol CMC 2,00 % O₂ od 0 mol/mol do 0,002 mol/mol CMC 0,00001 mol/mol O₂ od 0,002 mol/mol do 0,24 mol/mol CMC 0,54 % CO₂ od 0 mol/mol do 0,24 mol/mol CMC 0,00001 mol/mol CO₂ od 0,002 mol/mol do 0,24 mol/mol CMC 0,54 % Koncentrace plynnych slozek Kalibrace – emise Porovnani s plynnym standardem pripravenym v kalibratoru v objemove definovane smesi RM s inertnim plynem NO 0 µmol/mol az 6 µmol/mol CMC 0,03 µmol/mol NO 6 µmol/mol az 3000 µmol/mol CMC 0,50 % CO 0 µmol/mol az 42 µmol/mol CMC 0,12 µmol/mol CO 42 µmol/mol az 8000 µmol/mol CMC 0,28 % SO₂ 0 µmol/mol az 5 µmol/mol CMC 0,03 µmol/mol SO₂ 5 µmol/mol az 2000 µmol/mol CMC 0,54 % C₃H₈ 0 µmol/mol az 11 µmol/mol CMC 0,05 µmol/mol C₃H₈ 11 µmol/mol az 5000 µmol/mol CMC 0,42 % CH₄ 0 µmol/mol az 10 µmol/mol CMC 0,05 µmol/mol CH₄ 10 µmol/mol az 40000 µmol/mol CMC 0,46 % NH₃ 0 µmol/mol az 6 µmol/mol CMC 0,012 µmol/mol NH₃ 6 µmol/mol az 2000 µmol/mol CMC 2,00 % N₂O 0 µmol/mol az 6 µmol/mol CMC 0,12 µmol/mol N₂O 6 µmol/mol az 2000 µmol/mol CMC 2,00 % NO₂ 0 µmol/mol az 1,5 µmol/mol CMC 0,03 µmol/mol NO₂ 1,5 µmol/mol az 2000 µmol/mol CMC 2,00 % O₂ 0 mol/mol az 0,002 mol/mol CMC 0,00001 mol/mol O₂ 0,002 mol/mol az 0,24 mol/mol CMC 0,54 % CO₂ 0 mol/mol az 0,24 mol/mol CMC 0,00001 mol/mol CO₂ 0,002 mol/mol az 0,24 mol/mol CMC 0,54 % IP 101-03 (EN ISO 9169; ISO 11095)","search_en":"Concentration of gaseous components Calibration – emissions Comparison with a gas standard prepared in a calibrator in a volumetrically defined mixture of RM with inert gas NO 0 µmol/mol to 6 µmol/mol CMC 0,03 µmol/mol NO 6 µmol/mol to 3000 µmol/mol CMC 0,50 % CO 0 µmol/mol to 42 µmol/mol CMC 0,12 µmol/mol CO 42 µmol/mol to 8000 µmol/mol CMC 0,28 % SO₂ 0 µmol/mol to 5 µmol/mol CMC 0,03 µmol/mol SO₂ 5 µmol/mol to 2000 µmol/mol CMC 0,54 % C₃H₈ 0 µmol/mol to 11 µmol/mol CMC 0,05 µmol/mol C₃H₈ 11 µmol/mol to 5000 µmol/mol CMC 0,42 % CH₄ 0 µmol/mol to 10 µmol/mol CMC 0,05 µmol/mol CH₄ 10 µmol/mol to 40000 µmol/mol CMC 0,46 % NH₃ 0 µmol/mol to 6 µmol/mol CMC 0,012 µmol/mol NH₃ 6 µmol/mol to 2000 µmol/mol CMC 2,00 % N₂O 0 µmol/mol to 6 µmol/mol CMC 0,12 µmol/mol N₂O 6 µmol/mol to 2000 µmol/mol CMC 2,00 % NO₂ 0 µmol/mol to 1,5 µmol/mol CMC 0,03 µmol/mol NO₂ 1,5 µmol/mol to 2000 µmol/mol CMC 2,00 % O₂ 0 mol/mol to 0,002 mol/mol CMC 0,00001 mol/mol O₂ 0,002 mol/mol to 0,24 mol/mol CMC 0,54 % CO₂ 0 mol/mol to 0,24 mol/mol CMC 0,00001 mol/mol CO₂ 0,002 mol/mol to 0,24 mol/mol CMC 0,54 % IP 101-03 (EN ISO 9169; ISO 11095)","search_zh":"气态组分浓度 校准 – 排放 与在校准器中由标准物质与惰性气体按体积配制的气体标准比较 一氧化氮 NO 0 µmol/mol 至 6 µmol/mol CMC 0,03 µmol/mol 一氧化氮 NO 6 µmol/mol 至 3000 µmol/mol CMC 0,50 % 一氧化碳 CO 0 µmol/mol 至 42 µmol/mol CMC 0,12 µmol/mol 一氧化碳 CO 42 µmol/mol 至 8000 µmol/mol CMC 0,28 % 二氧化硫 SO₂ 0 µmol/mol 至 5 µmol/mol CMC 0,03 µmol/mol 二氧化硫 SO₂ 5 µmol/mol 至 2000 µmol/mol CMC 0,54 % 丙烷 C₃H₈ 0 µmol/mol 至 11 µmol/mol CMC 0,05 µmol/mol 丙烷 C₃H₈ 11 µmol/mol 至 5000 µmol/mol CMC 0,42 % 甲烷 CH₄ 0 µmol/mol 至 10 µmol/mol CMC 0,05 µmol/mol 甲烷 CH₄ 10 µmol/mol 至 40000 µmol/mol CMC 0,46 % 氨 NH₃ 0 µmol/mol 至 6 µmol/mol CMC 0,012 µmol/mol 氨 NH₃ 6 µmol/mol 至 2000 µmol/mol CMC 2,00 % 一氧化二氮 N₂O 0 µmol/mol 至 6 µmol/mol CMC 0,12 µmol/mol 一氧化二氮 N₂O 6 µmol/mol 至 2000 µmol/mol CMC 2,00 % 二氧化氮 NO₂ 0 µmol/mol 至 1,5 µmol/mol CMC 0,03 µmol/mol 二氧化氮 NO₂ 1,5 µmol/mol 至 2000 µmol/mol CMC 2,00 % 氧 O₂ 0 mol/mol 至 0,002 mol/mol CMC 0,00001 mol/mol 氧 O₂ 0,002 mol/mol 至 0,24 mol/mol CMC 0,54 % 二氧化碳 CO₂ 0 mol/mol 至 0,24 mol/mol CMC 0,00001 mol/mol 二氧化碳 CO₂ 0,002 mol/mol 至 0,24 mol/mol CMC 0,54 % IP 101-03 (EN ISO 9169; ISO 11095)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5921b7484934bb4e76d23a7d","lab_id":"6ade8b35ff06824761708114","country":"CZ","accr_number":"2319","accr_body":"ČIA","row_label":"2","test_object":"Sprawność konwertera NO₂ - NO (do 500 µmol/mol NO)","test_object_en":"Efficiency of the NO₂ - NO converter (up to 500 µmol/mol NO)","test_object_zh":"NO₂ - NO 转换器效率（NO 至 500 µmol/mol）","test_object_cs":"Účinnost konvertoru NO₂ - NO (do 500 µmol/mol NO)","methodology":"Wzorcowanie – emisje","methodology_en":"Calibration – emissions","methodology_zh":"校准 – 排放","methodology_cs":"Kalibrace – emise","parameters":[{"name":"","range":"od 0 % do 100 %","cmc":"0,4 % abs"}],"parameters_en":[{"name":"","range":"0 % to 100 %","cmc":"0,4 % abs"}],"parameters_zh":[{"name":"","range":"0 % 至 100 %","cmc":"0,4 % abs"}],"parameters_cs":[{"name":"","range":"0 % až 100 %","cmc":"0,4 % abs"}],"technique":"Pomiar bezpośredni","technique_en":"Direct measurement","technique_zh":"直接测量","technique_cs":"Přímé měření","techniques":["Pomiar bezpośredni"],"techniques_en":["Direct measurement"],"techniques_zh":["直接测量"],"techniques_cs":["Přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – emisje\nod 0 % do 100 % CMC 0,4 % abs\nPomiar bezpośredni","reference":"IP 102-01 (EN ISO 9169; EN 14792; US EPA 40 CFR Ch.I § 86.332 79)","norm_bases":["IP 102-01","EN ISO 9169","EN 14792","US EPA 40 CFR Ch.I § 86.332 79"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: emisje","regulatory_area_en":"CMC for the field of measured quantity: Emissions","regulatory_area_zh":"被测量领域的CMC：排放","regulatory_area_cs":"CMC pro obor měřené veličiny: Emise","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawność konwertera NO₂ - NO (do 500 µmol/mol NO) Wzorcowanie – emisje Pomiar bezpośredni od 0 % do 100 % CMC 0,4 % abs Účinnost konvertoru NO₂ - NO (do 500 µmol/mol NO) Kalibrace – emise Přímé měření 0 % až 100 % CMC 0,4 % abs IP 102-01 (EN ISO 9169; EN 14792; US EPA 40 CFR Ch.I § 86.332 79) Sprawnosc konwertera NO₂ - NO (do 500 µmol/mol NO) Wzorcowanie – emisje Pomiar bezposredni od 0 % do 100 % CMC 0,4 % abs Ucinnost konvertoru NO₂ - NO (do 500 µmol/mol NO) Kalibrace – emise Prime mereni 0 % az 100 % CMC 0,4 % abs IP 102-01 (EN ISO 9169; EN 14792; US EPA 40 CFR Ch.I § 86.332 79)","search_en":"Efficiency of the NO₂ - NO converter (up to 500 µmol/mol NO) Calibration – emissions Direct measurement 0 % to 100 % CMC 0,4 % abs IP 102-01 (EN ISO 9169; EN 14792; US EPA 40 CFR Ch.I § 86.332 79)","search_zh":"NO₂ - NO 转换器效率（NO 至 500 µmol/mol） 校准 – 排放 直接测量 0 % 至 100 % CMC 0,4 % abs IP 102-01 (EN ISO 9169; EN 14792; US EPA 40 CFR Ch.I § 86.332 79)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}