{"lab":{"_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","address":"Dělnická 81, 272 01 Kladno","categories":["metrology"],"city":"Kladno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.121135,50.1461938]},"map_coord":[50.1461938,14.121135],"map_geo":"cai-mapa","methods_count":12,"name":"TERMOSONDY Kladno, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: temperatura i wielkości elektryczne.","search_text":"termosondy kladno, spol. s r.o. dělnická 81, 272 01 kladno 2305","source_page_url":"https://www.cai.cz/?subjekt=2305-termosondy-kladno-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"11-11-2029","website":"www.termosondy.cz","certificate_date":"11.11.2024","certificate_no":"591/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: temperatura i wielkości elektryczne.","en":"Calibration of temperature and electrical quantities measuring devices.","zh":"温度和电学量领域的校准。","cs":"Kalibrace v oborech teplota a elektrické veličiny."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"laboratorium wzorcujące","lab_division_cs":"kalibrační laboratoř","lab_division_en":"calibration laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"233201202a2957eeed55daa128dfb6664d1202f2cffa9773b27d6965fdde3291","source_pdf_url":"https://www.cai.cz/OA/pdf/P591_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P591_2024_EN.pdf"},"methods":[{"_id":"9af9c4526f56b7644de20490","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"1","test_object":"Termoelektryczne czujniki temperatury z metali szlachetnych","test_object_en":"Thermoelectric temperature sensors made of precious metals","test_object_zh":"贵金属热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty z drahých kovů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 200 °C","cmc":"0,8 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"1,4 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"1,9 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"2,3 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"2,8 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"3,1 °C"},{"name":"","range":"od 1200 °C do 1554 °C","cmc":"4,9 °C"}],"parameters_en":[{"name":"","range":"0 °C to 200 °C","cmc":"0,8 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"1,4 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C to 800 °C","cmc":"2,3 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"2,8 °C"},{"name":"","range":"1000 °C to 1200 °C","cmc":"3,1 °C"},{"name":"","range":"1200 °C to 1554 °C","cmc":"4,9 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 200 °C","cmc":"0,8 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"1,4 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"2,3 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"2,8 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"3,1 °C"},{"name":"","range":"1200 °C 至 1554 °C","cmc":"4,9 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 200 °C","cmc":"0,8 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"1,4 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"2,3 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"2,8 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"3,1 °C"},{"name":"","range":"1200 °C až 1554 °C","cmc":"4,9 °C"}],"technique":"0 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C i 1200 °C do 1554 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym","technique_en":"0 °C to 200 °C: comparison with a standard thermometer in a liquid bath; 200 °C to 400 °C and 1200 °C to 1554 °C: comparison with a standard thermometer in a vertical furnace; 400 °C to 1200 °C: comparison with a standard thermometer in a horizontal furnace","technique_zh":"0 °C 至 200 °C：在液槽中与标准温度计比较；200 °C 至 400 °C 和 1200 °C 至 1554 °C：在立式炉中与标准温度计比较；400 °C 至 1200 °C：在卧式炉中与标准温度计比较","technique_cs":"0 °C až 200 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 200 °C až 400 °C a 1200 °C až 1554 °C: Porovnání s etalonovým teploměrem ve vertikální peci; 400 °C až 1200 °C: Porovnání s etalonovým teploměrem v horizontální peci","techniques":["0 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C i 1200 °C do 1554 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym"],"techniques_en":["0 °C to 200 °C: comparison with a standard thermometer in a liquid bath; 200 °C to 400 °C and 1200 °C to 1554 °C: comparison with a standard thermometer in a vertical furnace; 400 °C to 1200 °C: comparison with a standard thermometer in a horizontal furnace"],"techniques_zh":["0 °C 至 200 °C：在液槽中与标准温度计比较；200 °C 至 400 °C 和 1200 °C 至 1554 °C：在立式炉中与标准温度计比较；400 °C 至 1200 °C：在卧式炉中与标准温度计比较"],"techniques_cs":["0 °C až 200 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 200 °C až 400 °C a 1200 °C až 1554 °C: Porovnání s etalonovým teploměrem ve vertikální peci; 400 °C až 1200 °C: Porovnání s etalonovým teploměrem v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 0 °C do 200 °C CMC 0,8 °C\nod 200 °C do 400 °C CMC 1,4 °C\nod 400 °C do 600 °C CMC 1,9 °C\nod 600 °C do 800 °C CMC 2,3 °C\nod 800 °C do 1000 °C CMC 2,8 °C\nod 1000 °C do 1200 °C CMC 3,1 °C\nod 1200 °C do 1554 °C CMC 4,9 °C\n0 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C i 1200 °C do 1554 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym","reference":"PP-Th 7/1-5-1","norm_bases":["PP-Th 7/1-5-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury z metali szlachetnych Wzorcowanie – temperatura 0 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C i 1200 °C do 1554 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym od 0 °C do 200 °C CMC 0,8 °C od 200 °C do 400 °C CMC 1,4 °C od 400 °C do 600 °C CMC 1,9 °C od 600 °C do 800 °C CMC 2,3 °C od 800 °C do 1000 °C CMC 2,8 °C od 1000 °C do 1200 °C CMC 3,1 °C od 1200 °C do 1554 °C CMC 4,9 °C Termoelektrické snímače teploty z drahých kovů Kalibrace – teplota 0 °C až 200 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 200 °C až 400 °C a 1200 °C až 1554 °C: Porovnání s etalonovým teploměrem ve vertikální peci; 400 °C až 1200 °C: Porovnání s etalonovým teploměrem v horizontální peci 0 °C až 200 °C CMC 0,8 °C 200 °C až 400 °C CMC 1,4 °C 400 °C až 600 °C CMC 1,9 °C 600 °C až 800 °C CMC 2,3 °C 800 °C až 1000 °C CMC 2,8 °C 1000 °C až 1200 °C CMC 3,1 °C 1200 °C až 1554 °C CMC 4,9 °C PP-Th 7/1-5-1 Termoelektryczne czujniki temperatury z metali szlachetnych Wzorcowanie – temperatura 0 °C do 200 °C: porownanie z termometrem wzorcowym w lazni cieczowej; 200 °C do 400 °C i 1200 °C do 1554 °C: porownanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porownanie z termometrem wzorcowym w piecu poziomym od 0 °C do 200 °C CMC 0,8 °C od 200 °C do 400 °C CMC 1,4 °C od 400 °C do 600 °C CMC 1,9 °C od 600 °C do 800 °C CMC 2,3 °C od 800 °C do 1000 °C CMC 2,8 °C od 1000 °C do 1200 °C CMC 3,1 °C od 1200 °C do 1554 °C CMC 4,9 °C Termoelektricke snimace teploty z drahych kovu Kalibrace – teplota 0 °C az 200 °C: Porovnani s etalonovym teplomerem v kapalinove lazni; 200 °C az 400 °C a 1200 °C az 1554 °C: Porovnani s etalonovym teplomerem ve vertikalni peci; 400 °C az 1200 °C: Porovnani s etalonovym teplomerem v horizontalni peci 0 °C az 200 °C CMC 0,8 °C 200 °C az 400 °C CMC 1,4 °C 400 °C az 600 °C CMC 1,9 °C 600 °C az 800 °C CMC 2,3 °C 800 °C az 1000 °C CMC 2,8 °C 1000 °C az 1200 °C CMC 3,1 °C 1200 °C az 1554 °C CMC 4,9 °C PP-Th 7/1-5-1","search_en":"Thermoelectric temperature sensors made of precious metals Calibration – temperature 0 °C to 200 °C: comparison with a standard thermometer in a liquid bath; 200 °C to 400 °C and 1200 °C to 1554 °C: comparison with a standard thermometer in a vertical furnace; 400 °C to 1200 °C: comparison with a standard thermometer in a horizontal furnace 0 °C to 200 °C CMC 0,8 °C 200 °C to 400 °C CMC 1,4 °C 400 °C to 600 °C CMC 1,9 °C 600 °C to 800 °C CMC 2,3 °C 800 °C to 1000 °C CMC 2,8 °C 1000 °C to 1200 °C CMC 3,1 °C 1200 °C to 1554 °C CMC 4,9 °C PP-Th 7/1-5-1","search_zh":"贵金属热电式温度传感器 校准 – 温度 0 °C 至 200 °C：在液槽中与标准温度计比较；200 °C 至 400 °C 和 1200 °C 至 1554 °C：在立式炉中与标准温度计比较；400 °C 至 1200 °C：在卧式炉中与标准温度计比较 0 °C 至 200 °C CMC 0,8 °C 200 °C 至 400 °C CMC 1,4 °C 400 °C 至 600 °C CMC 1,9 °C 600 °C 至 800 °C CMC 2,3 °C 800 °C 至 1000 °C CMC 2,8 °C 1000 °C 至 1200 °C CMC 3,1 °C 1200 °C 至 1554 °C CMC 4,9 °C PP-Th 7/1-5-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7669917d4ffdfe17fb37e831","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury z metali nieszlachetnych","test_object_en":"Thermoelectric temperature sensors made of common metals","test_object_zh":"贱金属热电式温度传感器","test_object_cs":"Termoelektrické snímače teploty z obecných kovů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 200 °C","cmc":"0,5 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"1,6 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"1,9 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"2,3 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"2,8 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"3,1 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"1,6 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C to 800 °C","cmc":"2,3 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"2,8 °C"},{"name":"","range":"1000 °C to 1200 °C","cmc":"3,1 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"1,6 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"2,3 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"2,8 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"3,1 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 200 °C","cmc":"0,5 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"1,6 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"1,9 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"2,3 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"2,8 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"3,1 °C"}],"technique":"-30 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym","technique_en":"-30 °C to 200 °C: comparison with a standard thermometer in a liquid bath; 200 °C to 400 °C: comparison with a standard thermometer in a vertical furnace; 400 °C to 1200 °C: comparison with a standard thermometer in a horizontal furnace","technique_zh":"-30 °C 至 200 °C：在液槽中与标准温度计比较；200 °C 至 400 °C：在立式炉中与标准温度计比较；400 °C 至 1200 °C：在卧式炉中与标准温度计比较","technique_cs":"-30 °C až 200 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 200 °C až 400 °C: Porovnání s etalonovým teploměrem ve vertikální peci; 400 °C až 1200 °C: Porovnání s etalonovým teploměrem v horizontální peci","techniques":["-30 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym"],"techniques_en":["-30 °C to 200 °C: comparison with a standard thermometer in a liquid bath; 200 °C to 400 °C: comparison with a standard thermometer in a vertical furnace; 400 °C to 1200 °C: comparison with a standard thermometer in a horizontal furnace"],"techniques_zh":["-30 °C 至 200 °C：在液槽中与标准温度计比较；200 °C 至 400 °C：在立式炉中与标准温度计比较；400 °C 至 1200 °C：在卧式炉中与标准温度计比较"],"techniques_cs":["-30 °C až 200 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 200 °C až 400 °C: Porovnání s etalonovým teploměrem ve vertikální peci; 400 °C až 1200 °C: Porovnání s etalonovým teploměrem v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 200 °C CMC 0,5 °C\nod 200 °C do 400 °C CMC 1,6 °C\nod 400 °C do 600 °C CMC 1,9 °C\nod 600 °C do 800 °C CMC 2,3 °C\nod 800 °C do 1000 °C CMC 2,8 °C\nod 1000 °C do 1200 °C CMC 3,1 °C\n-30 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym","reference":"PP-Th 7/1-5-1","norm_bases":["PP-Th 7/1-5-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury z metali nieszlachetnych Wzorcowanie – temperatura -30 °C do 200 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 200 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porównanie z termometrem wzorcowym w piecu poziomym od -30 °C do 200 °C CMC 0,5 °C od 200 °C do 400 °C CMC 1,6 °C od 400 °C do 600 °C CMC 1,9 °C od 600 °C do 800 °C CMC 2,3 °C od 800 °C do 1000 °C CMC 2,8 °C od 1000 °C do 1200 °C CMC 3,1 °C Termoelektrické snímače teploty z obecných kovů Kalibrace – teplota -30 °C až 200 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 200 °C až 400 °C: Porovnání s etalonovým teploměrem ve vertikální peci; 400 °C až 1200 °C: Porovnání s etalonovým teploměrem v horizontální peci -30 °C až 200 °C CMC 0,5 °C 200 °C až 400 °C CMC 1,6 °C 400 °C až 600 °C CMC 1,9 °C 600 °C až 800 °C CMC 2,3 °C 800 °C až 1000 °C CMC 2,8 °C 1000 °C až 1200 °C CMC 3,1 °C PP-Th 7/1-5-1 Termoelektryczne czujniki temperatury z metali nieszlachetnych Wzorcowanie – temperatura -30 °C do 200 °C: porownanie z termometrem wzorcowym w lazni cieczowej; 200 °C do 400 °C: porownanie z termometrem wzorcowym w piecu pionowym; 400 °C do 1200 °C: porownanie z termometrem wzorcowym w piecu poziomym od -30 °C do 200 °C CMC 0,5 °C od 200 °C do 400 °C CMC 1,6 °C od 400 °C do 600 °C CMC 1,9 °C od 600 °C do 800 °C CMC 2,3 °C od 800 °C do 1000 °C CMC 2,8 °C od 1000 °C do 1200 °C CMC 3,1 °C Termoelektricke snimace teploty z obecnych kovu Kalibrace – teplota -30 °C az 200 °C: Porovnani s etalonovym teplomerem v kapalinove lazni; 200 °C az 400 °C: Porovnani s etalonovym teplomerem ve vertikalni peci; 400 °C az 1200 °C: Porovnani s etalonovym teplomerem v horizontalni peci -30 °C az 200 °C CMC 0,5 °C 200 °C az 400 °C CMC 1,6 °C 400 °C az 600 °C CMC 1,9 °C 600 °C az 800 °C CMC 2,3 °C 800 °C az 1000 °C CMC 2,8 °C 1000 °C az 1200 °C CMC 3,1 °C PP-Th 7/1-5-1","search_en":"Thermoelectric temperature sensors made of common metals Calibration – temperature -30 °C to 200 °C: comparison with a standard thermometer in a liquid bath; 200 °C to 400 °C: comparison with a standard thermometer in a vertical furnace; 400 °C to 1200 °C: comparison with a standard thermometer in a horizontal furnace -30 °C to 200 °C CMC 0,5 °C 200 °C to 400 °C CMC 1,6 °C 400 °C to 600 °C CMC 1,9 °C 600 °C to 800 °C CMC 2,3 °C 800 °C to 1000 °C CMC 2,8 °C 1000 °C to 1200 °C CMC 3,1 °C PP-Th 7/1-5-1","search_zh":"贱金属热电式温度传感器 校准 – 温度 -30 °C 至 200 °C：在液槽中与标准温度计比较；200 °C 至 400 °C：在立式炉中与标准温度计比较；400 °C 至 1200 °C：在卧式炉中与标准温度计比较 -30 °C 至 200 °C CMC 0,5 °C 200 °C 至 400 °C CMC 1,6 °C 400 °C 至 600 °C CMC 1,9 °C 600 °C 至 800 °C CMC 2,3 °C 800 °C 至 1000 °C CMC 2,8 °C 1000 °C 至 1200 °C CMC 3,1 °C PP-Th 7/1-5-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15156d12927679f585044e7d","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"3","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0 °C","cmc":"0,12 °C"},{"name":"","range":"od -70 °C do -40 °C","cmc":"0,35 °C"},{"name":"","range":"od -40 °C do 50 °C","cmc":"0,16 °C"},{"name":"","range":"od 50 °C do 150 °C","cmc":"0,18 °C"},{"name":"","range":"od 150 °C do 300 °C","cmc":"0,60 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"0,71 °C"}],"parameters_en":[{"name":"","range":"0 °C","cmc":"0,12 °C"},{"name":"","range":"-70 °C to -40 °C","cmc":"0,35 °C"},{"name":"","range":"-40 °C to 50 °C","cmc":"0,16 °C"},{"name":"","range":"50 °C to 150 °C","cmc":"0,18 °C"},{"name":"","range":"150 °C to 300 °C","cmc":"0,60 °C"},{"name":"","range":"300 °C to 400 °C","cmc":"0,71 °C"}],"parameters_zh":[{"name":"","range":"0 °C","cmc":"0,12 °C"},{"name":"","range":"-70 °C 至 -40 °C","cmc":"0,35 °C"},{"name":"","range":"-40 °C 至 50 °C","cmc":"0,16 °C"},{"name":"","range":"50 °C 至 150 °C","cmc":"0,18 °C"},{"name":"","range":"150 °C 至 300 °C","cmc":"0,60 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"0,71 °C"}],"parameters_cs":[{"name":"","range":"0 °C","cmc":"0,12 °C"},{"name":"","range":"-70 °C až -40 °C","cmc":"0,35 °C"},{"name":"","range":"-40 °C až 50 °C","cmc":"0,16 °C"},{"name":"","range":"50 °C až 150 °C","cmc":"0,18 °C"},{"name":"","range":"150 °C až 300 °C","cmc":"0,60 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"0,71 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a standard thermometer in a liquid bath","technique_zh":"在液槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard thermometer in a liquid bath"],"techniques_zh":["在液槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\n0 °C CMC 0,12 °C\nod -70 °C do -40 °C CMC 0,35 °C\nod -40 °C do 50 °C CMC 0,16 °C\nod 50 °C do 150 °C CMC 0,18 °C\nod 150 °C do 300 °C CMC 0,60 °C\nod 300 °C do 400 °C CMC 0,71 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"PP-Th 7/1-5-2","norm_bases":["PP-Th 7/1-5-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej 0 °C CMC 0,12 °C od -70 °C do -40 °C CMC 0,35 °C od -40 °C do 50 °C CMC 0,16 °C od 50 °C do 150 °C CMC 0,18 °C od 150 °C do 300 °C CMC 0,60 °C od 300 °C do 400 °C CMC 0,71 °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni 0 °C CMC 0,12 °C -70 °C až -40 °C CMC 0,35 °C -40 °C až 50 °C CMC 0,16 °C 50 °C až 150 °C CMC 0,18 °C 150 °C až 300 °C CMC 0,60 °C 300 °C až 400 °C CMC 0,71 °C PP-Th 7/1-5-2 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej 0 °C CMC 0,12 °C od -70 °C do -40 °C CMC 0,35 °C od -40 °C do 50 °C CMC 0,16 °C od 50 °C do 150 °C CMC 0,18 °C od 150 °C do 300 °C CMC 0,60 °C od 300 °C do 400 °C CMC 0,71 °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni 0 °C CMC 0,12 °C -70 °C az -40 °C CMC 0,35 °C -40 °C az 50 °C CMC 0,16 °C 50 °C az 150 °C CMC 0,18 °C 150 °C az 300 °C CMC 0,60 °C 300 °C az 400 °C CMC 0,71 °C PP-Th 7/1-5-2","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a standard thermometer in a liquid bath 0 °C CMC 0,12 °C -70 °C to -40 °C CMC 0,35 °C -40 °C to 50 °C CMC 0,16 °C 50 °C to 150 °C CMC 0,18 °C 150 °C to 300 °C CMC 0,60 °C 300 °C to 400 °C CMC 0,71 °C PP-Th 7/1-5-2","search_zh":"电阻式温度传感器 校准 – 温度 在液槽中与标准温度计比较 0 °C CMC 0,12 °C -70 °C 至 -40 °C CMC 0,35 °C -40 °C 至 50 °C CMC 0,16 °C 50 °C 至 150 °C CMC 0,18 °C 150 °C 至 300 °C CMC 0,60 °C 300 °C 至 400 °C CMC 0,71 °C PP-Th 7/1-5-2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"898e7ab91b42522558d50c12","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"4","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0 °C","cmc":"0,18 °C"},{"name":"","range":"od -30 °C do 50 °C","cmc":"0,23 °C"},{"name":"","range":"od 50 °C do 150 °C","cmc":"0,25 °C"}],"parameters_en":[{"name":"","range":"0 °C","cmc":"0,18 °C"},{"name":"","range":"-30 °C to 50 °C","cmc":"0,23 °C"},{"name":"","range":"50 °C to 150 °C","cmc":"0,25 °C"}],"parameters_zh":[{"name":"","range":"0 °C","cmc":"0,18 °C"},{"name":"","range":"-30 °C 至 50 °C","cmc":"0,23 °C"},{"name":"","range":"50 °C 至 150 °C","cmc":"0,25 °C"}],"parameters_cs":[{"name":"","range":"0 °C","cmc":"0,18 °C"},{"name":"","range":"-30 °C až 50 °C","cmc":"0,23 °C"},{"name":"","range":"50 °C až 150 °C","cmc":"0,25 °C"}],"technique":"Porównanie z termometrem wzorcowym w łaźni cieczowej","technique_en":"Comparison with a standard thermometer in a liquid bath","technique_zh":"在液槽中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v kapalinové lázni","techniques":["Porównanie z termometrem wzorcowym w łaźni cieczowej"],"techniques_en":["Comparison with a standard thermometer in a liquid bath"],"techniques_zh":["在液槽中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\n0 °C CMC 0,18 °C\nod -30 °C do 50 °C CMC 0,23 °C\nod 50 °C do 150 °C CMC 0,25 °C\nPorównanie z termometrem wzorcowym w łaźni cieczowej","reference":"PP-Th 7/1-5-4","norm_bases":["PP-Th 7/1-5-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w łaźni cieczowej 0 °C CMC 0,18 °C od -30 °C do 50 °C CMC 0,23 °C od 50 °C do 150 °C CMC 0,25 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem v kapalinové lázni 0 °C CMC 0,18 °C -30 °C až 50 °C CMC 0,23 °C 50 °C až 150 °C CMC 0,25 °C PP-Th 7/1-5-4 Termometry szklane Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w lazni cieczowej 0 °C CMC 0,18 °C od -30 °C do 50 °C CMC 0,23 °C od 50 °C do 150 °C CMC 0,25 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem v kapalinove lazni 0 °C CMC 0,18 °C -30 °C az 50 °C CMC 0,23 °C 50 °C az 150 °C CMC 0,25 °C PP-Th 7/1-5-4","search_en":"Glass thermometers Calibration – temperature Comparison with a standard thermometer in a liquid bath 0 °C CMC 0,18 °C -30 °C to 50 °C CMC 0,23 °C 50 °C to 150 °C CMC 0,25 °C PP-Th 7/1-5-4","search_zh":"玻璃温度计 校准 – 温度 在液槽中与标准温度计比较 0 °C CMC 0,18 °C -30 °C 至 50 °C CMC 0,23 °C 50 °C 至 150 °C CMC 0,25 °C PP-Th 7/1-5-4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a332d9ec3a1a49acb7366053","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"5","test_object":"Termometry na podczerwień (pirometry)","test_object_en":"Infrared thermometers","test_object_zh":"红外温度计","test_object_cs":"Infračervené teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 50 °C do 200 °C","cmc":"4,0 °C"},{"name":"","range":"od 200 °C do 400 °C","cmc":"5,0 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"5,8 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"7,9 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"10 °C"},{"name":"","range":"od 1000 °C do 1100 °C","cmc":"11 °C"}],"parameters_en":[{"name":"","range":"50 °C to 200 °C","cmc":"4,0 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"5,0 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"5,8 °C"},{"name":"","range":"600 °C to 800 °C","cmc":"7,9 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"10 °C"},{"name":"","range":"1000 °C to 1100 °C","cmc":"11 °C"}],"parameters_zh":[{"name":"","range":"50 °C 至 200 °C","cmc":"4,0 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"5,0 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"5,8 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"7,9 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"10 °C"},{"name":"","range":"1000 °C 至 1100 °C","cmc":"11 °C"}],"parameters_cs":[{"name":"","range":"50 °C až 200 °C","cmc":"4,0 °C"},{"name":"","range":"200 °C až 400 °C","cmc":"5,0 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"5,8 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"7,9 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"10 °C"},{"name":"","range":"1000 °C až 1100 °C","cmc":"11 °C"}],"technique":"Porównanie z termometrem wzorcowym na modelu ciała czarnego","technique_en":"Comparison with a standard thermometer on a black body model","technique_zh":"在黑体模型上与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem na modelu černého tělesa","techniques":["Porównanie z termometrem wzorcowym na modelu ciała czarnego"],"techniques_en":["Comparison with a standard thermometer on a black body model"],"techniques_zh":["在黑体模型上与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem na modelu černého tělesa"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 50 °C do 200 °C CMC 4,0 °C\nod 200 °C do 400 °C CMC 5,0 °C\nod 400 °C do 600 °C CMC 5,8 °C\nod 600 °C do 800 °C CMC 7,9 °C\nod 800 °C do 1000 °C CMC 10 °C\nod 1000 °C do 1100 °C CMC 11 °C\nPorównanie z termometrem wzorcowym na modelu ciała czarnego","reference":"PP-Th 7/1-5-5","norm_bases":["PP-Th 7/1-5-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry na podczerwień (pirometry) Wzorcowanie – temperatura Porównanie z termometrem wzorcowym na modelu ciała czarnego od 50 °C do 200 °C CMC 4,0 °C od 200 °C do 400 °C CMC 5,0 °C od 400 °C do 600 °C CMC 5,8 °C od 600 °C do 800 °C CMC 7,9 °C od 800 °C do 1000 °C CMC 10 °C od 1000 °C do 1100 °C CMC 11 °C Infračervené teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem na modelu černého tělesa 50 °C až 200 °C CMC 4,0 °C 200 °C až 400 °C CMC 5,0 °C 400 °C až 600 °C CMC 5,8 °C 600 °C až 800 °C CMC 7,9 °C 800 °C až 1000 °C CMC 10 °C 1000 °C až 1100 °C CMC 11 °C PP-Th 7/1-5-5 Termometry na podczerwien (pirometry) Wzorcowanie – temperatura Porownanie z termometrem wzorcowym na modelu ciala czarnego od 50 °C do 200 °C CMC 4,0 °C od 200 °C do 400 °C CMC 5,0 °C od 400 °C do 600 °C CMC 5,8 °C od 600 °C do 800 °C CMC 7,9 °C od 800 °C do 1000 °C CMC 10 °C od 1000 °C do 1100 °C CMC 11 °C Infracervene teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem na modelu cerneho telesa 50 °C az 200 °C CMC 4,0 °C 200 °C az 400 °C CMC 5,0 °C 400 °C az 600 °C CMC 5,8 °C 600 °C az 800 °C CMC 7,9 °C 800 °C az 1000 °C CMC 10 °C 1000 °C az 1100 °C CMC 11 °C PP-Th 7/1-5-5","search_en":"Infrared thermometers Calibration – temperature Comparison with a standard thermometer on a black body model 50 °C to 200 °C CMC 4,0 °C 200 °C to 400 °C CMC 5,0 °C 400 °C to 600 °C CMC 5,8 °C 600 °C to 800 °C CMC 7,9 °C 800 °C to 1000 °C CMC 10 °C 1000 °C to 1100 °C CMC 11 °C PP-Th 7/1-5-5","search_zh":"红外温度计 校准 – 温度 在黑体模型上与标准温度计比较 50 °C 至 200 °C CMC 4,0 °C 200 °C 至 400 °C CMC 5,0 °C 400 °C 至 600 °C CMC 5,8 °C 600 °C 至 800 °C CMC 7,9 °C 800 °C 至 1000 °C CMC 10 °C 1000 °C 至 1100 °C CMC 11 °C PP-Th 7/1-5-5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"398696ea0b955c82954dab37","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"6","test_object":"Termometry stykowe","test_object_en":"Contact thermometers","test_object_zh":"接触式温度计","test_object_cs":"Dotykové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 25 °C","cmc":"1,5 °C"},{"name":"","range":"od 25 °C do 100 °C","cmc":"2,0 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"4,3 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"4,9 °C"}],"parameters_en":[{"name":"","range":"0 °C to 25 °C","cmc":"1,5 °C"},{"name":"","range":"25 °C to 100 °C","cmc":"2,0 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"4,3 °C"},{"name":"","range":"200 °C to 300 °C","cmc":"4,9 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 25 °C","cmc":"1,5 °C"},{"name":"","range":"25 °C 至 100 °C","cmc":"2,0 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"4,3 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"4,9 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 25 °C","cmc":"1,5 °C"},{"name":"","range":"25 °C až 100 °C","cmc":"2,0 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"4,3 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"4,9 °C"}],"technique":"0 °C do 100 °C: porównanie z termometrem wzorcowym na aluminiowej płycie stykowej; 100 °C do 300 °C: porównanie z termometrem wzorcowym na miedzianej płycie stykowej","technique_en":"0 °C to 100 °C: comparison with a standard thermometer on an Al contact plate; 100 °C to 300 °C: comparison with a standard thermometer on a Cu contact plate","technique_zh":"0 °C 至 100 °C：在铝制接触板上与标准温度计比较；100 °C 至 300 °C：在铜制接触板上与标准温度计比较","technique_cs":"0 °C až 100 °C: Porovnání s etalonovým teploměrem na hliníkové dotykové desce; 100 °C až 300 °C: Porovnání s etalonovým teploměrem na měděné dotykové desce","techniques":["0 °C do 100 °C: porównanie z termometrem wzorcowym na aluminiowej płycie stykowej; 100 °C do 300 °C: porównanie z termometrem wzorcowym na miedzianej płycie stykowej"],"techniques_en":["0 °C to 100 °C: comparison with a standard thermometer on an Al contact plate; 100 °C to 300 °C: comparison with a standard thermometer on a Cu contact plate"],"techniques_zh":["0 °C 至 100 °C：在铝制接触板上与标准温度计比较；100 °C 至 300 °C：在铜制接触板上与标准温度计比较"],"techniques_cs":["0 °C až 100 °C: Porovnání s etalonovým teploměrem na hliníkové dotykové desce; 100 °C až 300 °C: Porovnání s etalonovým teploměrem na měděné dotykové desce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 0 °C do 25 °C CMC 1,5 °C\nod 25 °C do 100 °C CMC 2,0 °C\nod 100 °C do 200 °C CMC 4,3 °C\nod 200 °C do 300 °C CMC 4,9 °C\n0 °C do 100 °C: porównanie z termometrem wzorcowym na aluminiowej płycie stykowej; 100 °C do 300 °C: porównanie z termometrem wzorcowym na miedzianej płycie stykowej","reference":"PP-Th 7/1-5-6","norm_bases":["PP-Th 7/1-5-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry stykowe Wzorcowanie – temperatura 0 °C do 100 °C: porównanie z termometrem wzorcowym na aluminiowej płycie stykowej; 100 °C do 300 °C: porównanie z termometrem wzorcowym na miedzianej płycie stykowej od 0 °C do 25 °C CMC 1,5 °C od 25 °C do 100 °C CMC 2,0 °C od 100 °C do 200 °C CMC 4,3 °C od 200 °C do 300 °C CMC 4,9 °C Dotykové teploměry Kalibrace – teplota 0 °C až 100 °C: Porovnání s etalonovým teploměrem na hliníkové dotykové desce; 100 °C až 300 °C: Porovnání s etalonovým teploměrem na měděné dotykové desce 0 °C až 25 °C CMC 1,5 °C 25 °C až 100 °C CMC 2,0 °C 100 °C až 200 °C CMC 4,3 °C 200 °C až 300 °C CMC 4,9 °C PP-Th 7/1-5-6 Termometry stykowe Wzorcowanie – temperatura 0 °C do 100 °C: porownanie z termometrem wzorcowym na aluminiowej plycie stykowej; 100 °C do 300 °C: porownanie z termometrem wzorcowym na miedzianej plycie stykowej od 0 °C do 25 °C CMC 1,5 °C od 25 °C do 100 °C CMC 2,0 °C od 100 °C do 200 °C CMC 4,3 °C od 200 °C do 300 °C CMC 4,9 °C Dotykove teplomery Kalibrace – teplota 0 °C az 100 °C: Porovnani s etalonovym teplomerem na hlinikove dotykove desce; 100 °C az 300 °C: Porovnani s etalonovym teplomerem na medene dotykove desce 0 °C az 25 °C CMC 1,5 °C 25 °C az 100 °C CMC 2,0 °C 100 °C az 200 °C CMC 4,3 °C 200 °C az 300 °C CMC 4,9 °C PP-Th 7/1-5-6","search_en":"Contact thermometers Calibration – temperature 0 °C to 100 °C: comparison with a standard thermometer on an Al contact plate; 100 °C to 300 °C: comparison with a standard thermometer on a Cu contact plate 0 °C to 25 °C CMC 1,5 °C 25 °C to 100 °C CMC 2,0 °C 100 °C to 200 °C CMC 4,3 °C 200 °C to 300 °C CMC 4,9 °C PP-Th 7/1-5-6","search_zh":"接触式温度计 校准 – 温度 0 °C 至 100 °C：在铝制接触板上与标准温度计比较；100 °C 至 300 °C：在铜制接触板上与标准温度计比较 0 °C 至 25 °C CMC 1,5 °C 25 °C 至 100 °C CMC 2,0 °C 100 °C 至 200 °C CMC 4,3 °C 200 °C 至 300 °C CMC 4,9 °C PP-Th 7/1-5-6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"21003c8730371faa75791978","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"7","test_object":"Termometry bimetalowe i bezpośrednio wskazujące","test_object_en":"Bimetal and direct indicating thermometers","test_object_zh":"双金属和直读式温度计","test_object_cs":"Bimetalové a přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0 °C","cmc":"0,28 °C"},{"name":"","range":"od -30 °C do 50 °C","cmc":"0,30 °C"},{"name":"","range":"od 50 °C do 150 °C","cmc":"0,47 °C"},{"name":"","range":"od 150 °C do 300 °C","cmc":"1,0 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"2,2 °C"}],"parameters_en":[{"name":"","range":"0 °C","cmc":"0,28 °C"},{"name":"","range":"-30 °C to 50 °C","cmc":"0,30 °C"},{"name":"","range":"50 °C to 150 °C","cmc":"0,47 °C"},{"name":"","range":"150 °C to 300 °C","cmc":"1,0 °C"},{"name":"","range":"300 °C to 400 °C","cmc":"2,2 °C"}],"parameters_zh":[{"name":"","range":"0 °C","cmc":"0,28 °C"},{"name":"","range":"-30 °C 至 50 °C","cmc":"0,30 °C"},{"name":"","range":"50 °C 至 150 °C","cmc":"0,47 °C"},{"name":"","range":"150 °C 至 300 °C","cmc":"1,0 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"2,2 °C"}],"parameters_cs":[{"name":"","range":"0 °C","cmc":"0,28 °C"},{"name":"","range":"-30 °C až 50 °C","cmc":"0,30 °C"},{"name":"","range":"50 °C až 150 °C","cmc":"0,47 °C"},{"name":"","range":"150 °C až 300 °C","cmc":"1,0 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"2,2 °C"}],"technique":"0 °C i -30 °C do 150 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 150 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym","technique_en":"0 °C and -30 °C to 150 °C: comparison with a standard thermometer in a liquid bath; 150 °C to 400 °C: comparison with a standard thermometer in a vertical furnace","technique_zh":"0 °C 和 -30 °C 至 150 °C：在液槽中与标准温度计比较；150 °C 至 400 °C：在立式炉中与标准温度计比较","technique_cs":"0 °C a -30 °C až 150 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 150 °C až 400 °C: Porovnání s etalonovým teploměrem ve vertikální peci","techniques":["0 °C i -30 °C do 150 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 150 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym"],"techniques_en":["0 °C and -30 °C to 150 °C: comparison with a standard thermometer in a liquid bath; 150 °C to 400 °C: comparison with a standard thermometer in a vertical furnace"],"techniques_zh":["0 °C 和 -30 °C 至 150 °C：在液槽中与标准温度计比较；150 °C 至 400 °C：在立式炉中与标准温度计比较"],"techniques_cs":["0 °C a -30 °C až 150 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 150 °C až 400 °C: Porovnání s etalonovým teploměrem ve vertikální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\n0 °C CMC 0,28 °C\nod -30 °C do 50 °C CMC 0,30 °C\nod 50 °C do 150 °C CMC 0,47 °C\nod 150 °C do 300 °C CMC 1,0 °C\nod 300 °C do 400 °C CMC 2,2 °C\n0 °C i -30 °C do 150 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 150 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym","reference":"PP-Th 7/1-5-17","norm_bases":["PP-Th 7/1-5-17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bimetalowe i bezpośrednio wskazujące Wzorcowanie – temperatura 0 °C i -30 °C do 150 °C: porównanie z termometrem wzorcowym w łaźni cieczowej; 150 °C do 400 °C: porównanie z termometrem wzorcowym w piecu pionowym 0 °C CMC 0,28 °C od -30 °C do 50 °C CMC 0,30 °C od 50 °C do 150 °C CMC 0,47 °C od 150 °C do 300 °C CMC 1,0 °C od 300 °C do 400 °C CMC 2,2 °C Bimetalové a přímoukazující teploměry Kalibrace – teplota 0 °C a -30 °C až 150 °C: Porovnání s etalonovým teploměrem v kapalinové lázni; 150 °C až 400 °C: Porovnání s etalonovým teploměrem ve vertikální peci 0 °C CMC 0,28 °C -30 °C až 50 °C CMC 0,30 °C 50 °C až 150 °C CMC 0,47 °C 150 °C až 300 °C CMC 1,0 °C 300 °C až 400 °C CMC 2,2 °C PP-Th 7/1-5-17 Termometry bimetalowe i bezposrednio wskazujace Wzorcowanie – temperatura 0 °C i -30 °C do 150 °C: porownanie z termometrem wzorcowym w lazni cieczowej; 150 °C do 400 °C: porownanie z termometrem wzorcowym w piecu pionowym 0 °C CMC 0,28 °C od -30 °C do 50 °C CMC 0,30 °C od 50 °C do 150 °C CMC 0,47 °C od 150 °C do 300 °C CMC 1,0 °C od 300 °C do 400 °C CMC 2,2 °C Bimetalove a primoukazujici teplomery Kalibrace – teplota 0 °C a -30 °C az 150 °C: Porovnani s etalonovym teplomerem v kapalinove lazni; 150 °C az 400 °C: Porovnani s etalonovym teplomerem ve vertikalni peci 0 °C CMC 0,28 °C -30 °C az 50 °C CMC 0,30 °C 50 °C az 150 °C CMC 0,47 °C 150 °C az 300 °C CMC 1,0 °C 300 °C az 400 °C CMC 2,2 °C PP-Th 7/1-5-17","search_en":"Bimetal and direct indicating thermometers Calibration – temperature 0 °C and -30 °C to 150 °C: comparison with a standard thermometer in a liquid bath; 150 °C to 400 °C: comparison with a standard thermometer in a vertical furnace 0 °C CMC 0,28 °C -30 °C to 50 °C CMC 0,30 °C 50 °C to 150 °C CMC 0,47 °C 150 °C to 300 °C CMC 1,0 °C 300 °C to 400 °C CMC 2,2 °C PP-Th 7/1-5-17","search_zh":"双金属和直读式温度计 校准 – 温度 0 °C 和 -30 °C 至 150 °C：在液槽中与标准温度计比较；150 °C 至 400 °C：在立式炉中与标准温度计比较 0 °C CMC 0,28 °C -30 °C 至 50 °C CMC 0,30 °C 50 °C 至 150 °C CMC 0,47 °C 150 °C 至 300 °C CMC 1,0 °C 300 °C 至 400 °C CMC 2,2 °C PP-Th 7/1-5-17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f673fdeb74fcc203ade13479","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"8","test_object":"Tory pomiarowe temperatury","test_object_en":"Temperature measuring chains","test_object_zh":"温度测量链","test_object_cs":"Měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -70 °C do -40 °C","cmc":"0,45 °C"},{"name":"","range":"od -40 °C do 150 °C","cmc":"0,30 °C"},{"name":"","range":"od 150 °C do 300 °C","cmc":"0,70 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"1,1 °C"},{"name":"","range":"od 400 °C do 600 °C","cmc":"2,9 °C"},{"name":"","range":"od 600 °C do 800 °C","cmc":"3,3 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"3,6 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"4,0 °C"},{"name":"","range":"od 1200 °C do 1554 °C","cmc":"5,9 °C"}],"parameters_en":[{"name":"","range":"-70 °C to -40 °C","cmc":"0,45 °C"},{"name":"","range":"-40 °C to 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C to 300 °C","cmc":"0,70 °C"},{"name":"","range":"300 °C to 400 °C","cmc":"1,1 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"2,9 °C"},{"name":"","range":"600 °C to 800 °C","cmc":"3,3 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"3,6 °C"},{"name":"","range":"1000 °C to 1200 °C","cmc":"4,0 °C"},{"name":"","range":"1200 °C to 1554 °C","cmc":"5,9 °C"}],"parameters_zh":[{"name":"","range":"-70 °C 至 -40 °C","cmc":"0,45 °C"},{"name":"","range":"-40 °C 至 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C 至 300 °C","cmc":"0,70 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"1,1 °C"},{"name":"","range":"400 °C 至 600 °C","cmc":"2,9 °C"},{"name":"","range":"600 °C 至 800 °C","cmc":"3,3 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"3,6 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"4,0 °C"},{"name":"","range":"1200 °C 至 1554 °C","cmc":"5,9 °C"}],"parameters_cs":[{"name":"","range":"-70 °C až -40 °C","cmc":"0,45 °C"},{"name":"","range":"-40 °C až 150 °C","cmc":"0,30 °C"},{"name":"","range":"150 °C až 300 °C","cmc":"0,70 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"1,1 °C"},{"name":"","range":"400 °C až 600 °C","cmc":"2,9 °C"},{"name":"","range":"600 °C až 800 °C","cmc":"3,3 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"3,6 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"4,0 °C"},{"name":"","range":"1200 °C až 1554 °C","cmc":"5,9 °C"}],"technique":"Porównanie z termometrem wzorcowym w przestrzeni urządzenia termicznego","technique_en":"Comparison with a standard thermometer in the space of a thermal device","technique_zh":"在热设备空间内与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v prostoru teplotního zařízení","techniques":["Porównanie z termometrem wzorcowym w przestrzeni urządzenia termicznego"],"techniques_en":["Comparison with a standard thermometer in the space of a thermal device"],"techniques_zh":["在热设备空间内与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v prostoru teplotního zařízení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -70 °C do -40 °C CMC 0,45 °C\nod -40 °C do 150 °C CMC 0,30 °C\nod 150 °C do 300 °C CMC 0,70 °C\nod 300 °C do 400 °C CMC 1,1 °C\nod 400 °C do 600 °C CMC 2,9 °C\nod 600 °C do 800 °C CMC 3,3 °C\nod 800 °C do 1000 °C CMC 3,6 °C\nod 1000 °C do 1200 °C CMC 4,0 °C\nod 1200 °C do 1554 °C CMC 5,9 °C\nPorównanie z termometrem wzorcowym w przestrzeni urządzenia termicznego","reference":"PP-Th 7/1-5-7a, PP-Th 7/1-5-7b","norm_bases":["PP-Th 7/1-5-7a","PP-Th 7/1-5-7b"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w przestrzeni urządzenia termicznego od -70 °C do -40 °C CMC 0,45 °C od -40 °C do 150 °C CMC 0,30 °C od 150 °C do 300 °C CMC 0,70 °C od 300 °C do 400 °C CMC 1,1 °C od 400 °C do 600 °C CMC 2,9 °C od 600 °C do 800 °C CMC 3,3 °C od 800 °C do 1000 °C CMC 3,6 °C od 1000 °C do 1200 °C CMC 4,0 °C od 1200 °C do 1554 °C CMC 5,9 °C Měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým teploměrem v prostoru teplotního zařízení -70 °C až -40 °C CMC 0,45 °C -40 °C až 150 °C CMC 0,30 °C 150 °C až 300 °C CMC 0,70 °C 300 °C až 400 °C CMC 1,1 °C 400 °C až 600 °C CMC 2,9 °C 600 °C až 800 °C CMC 3,3 °C 800 °C až 1000 °C CMC 3,6 °C 1000 °C až 1200 °C CMC 4,0 °C 1200 °C až 1554 °C CMC 5,9 °C PP-Th 7/1-5-7a, PP-Th 7/1-5-7b Tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w przestrzeni urzadzenia termicznego od -70 °C do -40 °C CMC 0,45 °C od -40 °C do 150 °C CMC 0,30 °C od 150 °C do 300 °C CMC 0,70 °C od 300 °C do 400 °C CMC 1,1 °C od 400 °C do 600 °C CMC 2,9 °C od 600 °C do 800 °C CMC 3,3 °C od 800 °C do 1000 °C CMC 3,6 °C od 1000 °C do 1200 °C CMC 4,0 °C od 1200 °C do 1554 °C CMC 5,9 °C Merici retezce teploty Kalibrace – teplota Porovnani s etalonovym teplomerem v prostoru teplotniho zarizeni -70 °C az -40 °C CMC 0,45 °C -40 °C az 150 °C CMC 0,30 °C 150 °C az 300 °C CMC 0,70 °C 300 °C az 400 °C CMC 1,1 °C 400 °C az 600 °C CMC 2,9 °C 600 °C az 800 °C CMC 3,3 °C 800 °C az 1000 °C CMC 3,6 °C 1000 °C az 1200 °C CMC 4,0 °C 1200 °C az 1554 °C CMC 5,9 °C PP-Th 7/1-5-7a, PP-Th 7/1-5-7b","search_en":"Temperature measuring chains Calibration – temperature Comparison with a standard thermometer in the space of a thermal device -70 °C to -40 °C CMC 0,45 °C -40 °C to 150 °C CMC 0,30 °C 150 °C to 300 °C CMC 0,70 °C 300 °C to 400 °C CMC 1,1 °C 400 °C to 600 °C CMC 2,9 °C 600 °C to 800 °C CMC 3,3 °C 800 °C to 1000 °C CMC 3,6 °C 1000 °C to 1200 °C CMC 4,0 °C 1200 °C to 1554 °C CMC 5,9 °C PP-Th 7/1-5-7a, PP-Th 7/1-5-7b","search_zh":"温度测量链 校准 – 温度 在热设备空间内与标准温度计比较 -70 °C 至 -40 °C CMC 0,45 °C -40 °C 至 150 °C CMC 0,30 °C 150 °C 至 300 °C CMC 0,70 °C 300 °C 至 400 °C CMC 1,1 °C 400 °C 至 600 °C CMC 2,9 °C 600 °C 至 800 °C CMC 3,3 °C 800 °C 至 1000 °C CMC 3,6 °C 1000 °C 至 1200 °C CMC 4,0 °C 1200 °C 至 1554 °C CMC 5,9 °C PP-Th 7/1-5-7a, PP-Th 7/1-5-7b","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"647efcd755baf4cefa6c04f8","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"9","test_object":"Kalibratory temperatury (metodą elektryczną)","test_object_en":"Temperature calibrators (electric method)","test_object_zh":"温度校准器（电学方法）","test_object_cs":"Teplotní kalibrátory (elektrickou cestou)","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"termopary R","range":"od 0 °C do 1760 °C","cmc":"0,43 °C"},{"name":"termopary S","range":"od 0 °C do 1760 °C","cmc":"0,45 °C"},{"name":"termopary B","range":"od 0 °C do 1820 °C","cmc":"0,57 °C"},{"name":"termopary J","range":"od -80 °C do 1200 °C","cmc":"0,14 °C"},{"name":"termopary T","range":"od 0 °C do 400 °C","cmc":"0,09 °C"},{"name":"termopary E","range":"od 0 °C do 1000 °C","cmc":"0,12 °C"},{"name":"termopary K","range":"od -80 °C do 1300 °C","cmc":"0,19 °C"},{"name":"termopary N","range":"od -80 °C do 1300 °C","cmc":"0,18 °C"},{"name":"czujniki rezystancyjne","range":"od -80 °C do 850 °C","cmc":"0,16 °C"}],"parameters_en":[{"name":"thermocouples R","range":"0 °C to 1760 °C","cmc":"0,43 °C"},{"name":"thermocouples S","range":"0 °C to 1760 °C","cmc":"0,45 °C"},{"name":"thermocouples B","range":"0 °C to 1820 °C","cmc":"0,57 °C"},{"name":"thermocouples J","range":"-80 °C to 1200 °C","cmc":"0,14 °C"},{"name":"thermocouples T","range":"0 °C to 400 °C","cmc":"0,09 °C"},{"name":"thermocouples E","range":"0 °C to 1000 °C","cmc":"0,12 °C"},{"name":"thermocouples K","range":"-80 °C to 1300 °C","cmc":"0,19 °C"},{"name":"thermocouples N","range":"-80 °C to 1300 °C","cmc":"0,18 °C"},{"name":"resistance sensors","range":"-80 °C to 850 °C","cmc":"0,16 °C"}],"parameters_zh":[{"name":"R 型热电偶","range":"0 °C 至 1760 °C","cmc":"0,43 °C"},{"name":"S 型热电偶","range":"0 °C 至 1760 °C","cmc":"0,45 °C"},{"name":"B 型热电偶","range":"0 °C 至 1820 °C","cmc":"0,57 °C"},{"name":"J 型热电偶","range":"-80 °C 至 1200 °C","cmc":"0,14 °C"},{"name":"T 型热电偶","range":"0 °C 至 400 °C","cmc":"0,09 °C"},{"name":"E 型热电偶","range":"0 °C 至 1000 °C","cmc":"0,12 °C"},{"name":"K 型热电偶","range":"-80 °C 至 1300 °C","cmc":"0,19 °C"},{"name":"N 型热电偶","range":"-80 °C 至 1300 °C","cmc":"0,18 °C"},{"name":"电阻传感器","range":"-80 °C 至 850 °C","cmc":"0,16 °C"}],"parameters_cs":[{"name":"termoelektrické články R","range":"0 °C až 1760 °C","cmc":"0,43 °C"},{"name":"termoelektrické články S","range":"0 °C až 1760 °C","cmc":"0,45 °C"},{"name":"termoelektrické články B","range":"0 °C až 1820 °C","cmc":"0,57 °C"},{"name":"termoelektrické články J","range":"-80 °C až 1200 °C","cmc":"0,14 °C"},{"name":"termoelektrické články T","range":"0 °C až 400 °C","cmc":"0,09 °C"},{"name":"termoelektrické články E","range":"0 °C až 1000 °C","cmc":"0,12 °C"},{"name":"termoelektrické články K","range":"-80 °C až 1300 °C","cmc":"0,19 °C"},{"name":"termoelektrické články N","range":"-80 °C až 1300 °C","cmc":"0,18 °C"},{"name":"odporové snímače","range":"-80 °C až 850 °C","cmc":"0,16 °C"}],"technique":"Bezpośredni pomiar multimetrem wzorcowym 34401A","technique_en":"Direct measurement with a standard multimeter 34401A","technique_zh":"用标准多用表 34401A 直接测量","technique_cs":"Přímé měření etalonovým multimetrem 34401A","techniques":["Bezpośredni pomiar multimetrem wzorcowym 34401A"],"techniques_en":["Direct measurement with a standard multimeter 34401A"],"techniques_zh":["用标准多用表 34401A 直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem 34401A"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\ntermopary R od 0 °C do 1760 °C CMC 0,43 °C\ntermopary S od 0 °C do 1760 °C CMC 0,45 °C\ntermopary B od 0 °C do 1820 °C CMC 0,57 °C\ntermopary J od -80 °C do 1200 °C CMC 0,14 °C\ntermopary T od 0 °C do 400 °C CMC 0,09 °C\ntermopary E od 0 °C do 1000 °C CMC 0,12 °C\ntermopary K od -80 °C do 1300 °C CMC 0,19 °C\ntermopary N od -80 °C do 1300 °C CMC 0,18 °C\nczujniki rezystancyjne od -80 °C do 850 °C CMC 0,16 °C\nBezpośredni pomiar multimetrem wzorcowym 34401A","reference":"PP-Th 7/1-5-16","norm_bases":["PP-Th 7/1-5-16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kalibratory temperatury (metodą elektryczną) Wzorcowanie – temperatura Bezpośredni pomiar multimetrem wzorcowym 34401A termopary R od 0 °C do 1760 °C CMC 0,43 °C termopary S od 0 °C do 1760 °C CMC 0,45 °C termopary B od 0 °C do 1820 °C CMC 0,57 °C termopary J od -80 °C do 1200 °C CMC 0,14 °C termopary T od 0 °C do 400 °C CMC 0,09 °C termopary E od 0 °C do 1000 °C CMC 0,12 °C termopary K od -80 °C do 1300 °C CMC 0,19 °C termopary N od -80 °C do 1300 °C CMC 0,18 °C czujniki rezystancyjne od -80 °C do 850 °C CMC 0,16 °C Teplotní kalibrátory (elektrickou cestou) Kalibrace – teplota Přímé měření etalonovým multimetrem 34401A termoelektrické články R 0 °C až 1760 °C CMC 0,43 °C termoelektrické články S 0 °C až 1760 °C CMC 0,45 °C termoelektrické články B 0 °C až 1820 °C CMC 0,57 °C termoelektrické články J -80 °C až 1200 °C CMC 0,14 °C termoelektrické články T 0 °C až 400 °C CMC 0,09 °C termoelektrické články E 0 °C až 1000 °C CMC 0,12 °C termoelektrické články K -80 °C až 1300 °C CMC 0,19 °C termoelektrické články N -80 °C až 1300 °C CMC 0,18 °C odporové snímače -80 °C až 850 °C CMC 0,16 °C PP-Th 7/1-5-16 Kalibratory temperatury (metoda elektryczna) Wzorcowanie – temperatura Bezposredni pomiar multimetrem wzorcowym 34401A termopary R od 0 °C do 1760 °C CMC 0,43 °C termopary S od 0 °C do 1760 °C CMC 0,45 °C termopary B od 0 °C do 1820 °C CMC 0,57 °C termopary J od -80 °C do 1200 °C CMC 0,14 °C termopary T od 0 °C do 400 °C CMC 0,09 °C termopary E od 0 °C do 1000 °C CMC 0,12 °C termopary K od -80 °C do 1300 °C CMC 0,19 °C termopary N od -80 °C do 1300 °C CMC 0,18 °C czujniki rezystancyjne od -80 °C do 850 °C CMC 0,16 °C Teplotni kalibratory (elektrickou cestou) Kalibrace – teplota Prime mereni etalonovym multimetrem 34401A termoelektricke clanky R 0 °C az 1760 °C CMC 0,43 °C termoelektricke clanky S 0 °C az 1760 °C CMC 0,45 °C termoelektricke clanky B 0 °C az 1820 °C CMC 0,57 °C termoelektricke clanky J -80 °C az 1200 °C CMC 0,14 °C termoelektricke clanky T 0 °C az 400 °C CMC 0,09 °C termoelektricke clanky E 0 °C az 1000 °C CMC 0,12 °C termoelektricke clanky K -80 °C az 1300 °C CMC 0,19 °C termoelektricke clanky N -80 °C az 1300 °C CMC 0,18 °C odporove snimace -80 °C az 850 °C CMC 0,16 °C PP-Th 7/1-5-16","search_en":"Temperature calibrators (electric method) Calibration – temperature Direct measurement with a standard multimeter 34401A thermocouples R 0 °C to 1760 °C CMC 0,43 °C thermocouples S 0 °C to 1760 °C CMC 0,45 °C thermocouples B 0 °C to 1820 °C CMC 0,57 °C thermocouples J -80 °C to 1200 °C CMC 0,14 °C thermocouples T 0 °C to 400 °C CMC 0,09 °C thermocouples E 0 °C to 1000 °C CMC 0,12 °C thermocouples K -80 °C to 1300 °C CMC 0,19 °C thermocouples N -80 °C to 1300 °C CMC 0,18 °C resistance sensors -80 °C to 850 °C CMC 0,16 °C PP-Th 7/1-5-16","search_zh":"温度校准器（电学方法） 校准 – 温度 用标准多用表 34401A 直接测量 R 型热电偶 0 °C 至 1760 °C CMC 0,43 °C S 型热电偶 0 °C 至 1760 °C CMC 0,45 °C B 型热电偶 0 °C 至 1820 °C CMC 0,57 °C J 型热电偶 -80 °C 至 1200 °C CMC 0,14 °C T 型热电偶 0 °C 至 400 °C CMC 0,09 °C E 型热电偶 0 °C 至 1000 °C CMC 0,12 °C K 型热电偶 -80 °C 至 1300 °C CMC 0,19 °C N 型热电偶 -80 °C 至 1300 °C CMC 0,18 °C 电阻传感器 -80 °C 至 850 °C CMC 0,16 °C PP-Th 7/1-5-16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fb5c055bd9c26f18ad73f824","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe","test_object_en":"Direct-current voltage","test_object_zh":"直流电压","test_object_cs":"Stejnosměrné napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličin","parameters":[{"name":"","range":"0 mV","cmc":"3,5 µV"},{"name":"","range":"od 0 mV do 100 mV","cmc":"0,005 % + 3,5 µV"},{"name":"","range":"od 0,1 V do 1 V","cmc":"0,004 % + 7 µV"},{"name":"","range":"od 1 V do 10 V","cmc":"0,0035 % + 0,05 mV"},{"name":"","range":"od 10 V do 100 V","cmc":"0,0045 % + 0,6 mV"}],"parameters_en":[{"name":"","range":"0 mV","cmc":"3,5 µV"},{"name":"","range":"0 mV to 100 mV","cmc":"0,005 % + 3,5 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"0,004 % + 7 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0035 % + 0,05 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,0045 % + 0,6 mV"}],"parameters_zh":[{"name":"","range":"0 mV","cmc":"3,5 µV"},{"name":"","range":"0 mV 至 100 mV","cmc":"0,005 % + 3,5 µV"},{"name":"","range":"0,1 V 至 1 V","cmc":"0,004 % + 7 µV"},{"name":"","range":"1 V 至 10 V","cmc":"0,0035 % + 0,05 mV"},{"name":"","range":"10 V 至 100 V","cmc":"0,0045 % + 0,6 mV"}],"parameters_cs":[{"name":"","range":"0 mV","cmc":"3,5 µV"},{"name":"","range":"0 mV až 100 mV","cmc":"0,005 % + 3,5 µV"},{"name":"","range":"0,1 V až 1 V","cmc":"0,004 % + 7 µV"},{"name":"","range":"1 V až 10 V","cmc":"0,0035 % + 0,05 mV"},{"name":"","range":"10 V až 100 V","cmc":"0,0045 % + 0,6 mV"}],"technique":"Porównanie z multimetrem wzorcowym 34401A","technique_en":"Comparison with a standard multimeter 34401A","technique_zh":"与标准多用表 34401A 比较","technique_cs":"Porovnání s etalonovým multimetrem 34401A","techniques":["Porównanie z multimetrem wzorcowym 34401A"],"techniques_en":["Comparison with a standard multimeter 34401A"],"techniques_zh":["与标准多用表 34401A 比较"],"techniques_cs":["Porovnání s etalonovým multimetrem 34401A"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 mV CMC 3,5 µV\nod 0 mV do 100 mV CMC 0,005 % + 3,5 µV\nod 0,1 V do 1 V CMC 0,004 % + 7 µV\nod 1 V do 10 V CMC 0,0035 % + 0,05 mV\nod 10 V do 100 V CMC 0,0045 % + 0,6 mV\nPorównanie z multimetrem wzorcowym 34401A","reference":"PP-Th 7/1-5-16","norm_bases":["PP-Th 7/1-5-16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličin","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 34401A 0 mV CMC 3,5 µV od 0 mV do 100 mV CMC 0,005 % + 3,5 µV od 0,1 V do 1 V CMC 0,004 % + 7 µV od 1 V do 10 V CMC 0,0035 % + 0,05 mV od 10 V do 100 V CMC 0,0045 % + 0,6 mV Stejnosměrné napětí Kalibrace – elektrické veličin Porovnání s etalonovým multimetrem 34401A 0 mV CMC 3,5 µV 0 mV až 100 mV CMC 0,005 % + 3,5 µV 0,1 V až 1 V CMC 0,004 % + 7 µV 1 V až 10 V CMC 0,0035 % + 0,05 mV 10 V až 100 V CMC 0,0045 % + 0,6 mV PP-Th 7/1-5-16 Napiecie stale Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 34401A 0 mV CMC 3,5 µV od 0 mV do 100 mV CMC 0,005 % + 3,5 µV od 0,1 V do 1 V CMC 0,004 % + 7 µV od 1 V do 10 V CMC 0,0035 % + 0,05 mV od 10 V do 100 V CMC 0,0045 % + 0,6 mV Stejnosmerne napeti Kalibrace – elektricke velicin Porovnani s etalonovym multimetrem 34401A 0 mV CMC 3,5 µV 0 mV az 100 mV CMC 0,005 % + 3,5 µV 0,1 V az 1 V CMC 0,004 % + 7 µV 1 V az 10 V CMC 0,0035 % + 0,05 mV 10 V az 100 V CMC 0,0045 % + 0,6 mV PP-Th 7/1-5-16","search_en":"Direct-current voltage Calibration – electrical quantities Comparison with a standard multimeter 34401A 0 mV CMC 3,5 µV 0 mV to 100 mV CMC 0,005 % + 3,5 µV 0,1 V to 1 V CMC 0,004 % + 7 µV 1 V to 10 V CMC 0,0035 % + 0,05 mV 10 V to 100 V CMC 0,0045 % + 0,6 mV PP-Th 7/1-5-16","search_zh":"直流电压 校准 – 电学量 与标准多用表 34401A 比较 0 mV CMC 3,5 µV 0 mV 至 100 mV CMC 0,005 % + 3,5 µV 0,1 V 至 1 V CMC 0,004 % + 7 µV 1 V 至 10 V CMC 0,0035 % + 0,05 mV 10 V 至 100 V CMC 0,0045 % + 0,6 mV PP-Th 7/1-5-16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"968133c30bcc69799c32a03d","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały","test_object_en":"Direct current","test_object_zh":"直流电流","test_object_cs":"Stejnosměrný proud","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličin","parameters":[{"name":"","range":"0 mA","cmc":"2,0 µA"},{"name":"","range":"od 0 mA do 10 mA","cmc":"0,05 % + 2 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,05 % + 5 µA"},{"name":"","range":"od 0,1 A do 1 A","cmc":"0,10 % + 1 mA"},{"name":"","range":"od 1 A do 3 A","cmc":"0,12 % + 6 mA"}],"parameters_en":[{"name":"","range":"0 mA","cmc":"2,0 µA"},{"name":"","range":"0 mA to 10 mA","cmc":"0,05 % + 2 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,05 % + 5 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"0,10 % + 1 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,12 % + 6 mA"}],"parameters_zh":[{"name":"","range":"0 mA","cmc":"2,0 µA"},{"name":"","range":"0 mA 至 10 mA","cmc":"0,05 % + 2 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,05 % + 5 µA"},{"name":"","range":"0,1 A 至 1 A","cmc":"0,10 % + 1 mA"},{"name":"","range":"1 A 至 3 A","cmc":"0,12 % + 6 mA"}],"parameters_cs":[{"name":"","range":"0 mA","cmc":"2,0 µA"},{"name":"","range":"0 mA až 10 mA","cmc":"0,05 % + 2 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,05 % + 5 µA"},{"name":"","range":"0,1 A až 1 A","cmc":"0,10 % + 1 mA"},{"name":"","range":"1 A až 3 A","cmc":"0,12 % + 6 mA"}],"technique":"Porównanie z multimetrem wzorcowym 34401A","technique_en":"Comparison with a standard multimeter 34401A","technique_zh":"与标准多用表 34401A 比较","technique_cs":"Porovnání s etalonovým multimetrem 34401A","techniques":["Porównanie z multimetrem wzorcowym 34401A"],"techniques_en":["Comparison with a standard multimeter 34401A"],"techniques_zh":["与标准多用表 34401A 比较"],"techniques_cs":["Porovnání s etalonovým multimetrem 34401A"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 mA CMC 2,0 µA\nod 0 mA do 10 mA CMC 0,05 % + 2 µA\nod 10 mA do 100 mA CMC 0,05 % + 5 µA\nod 0,1 A do 1 A CMC 0,10 % + 1 mA\nod 1 A do 3 A CMC 0,12 % + 6 mA\nPorównanie z multimetrem wzorcowym 34401A","reference":"PP-Th 7/1-5-16","norm_bases":["PP-Th 7/1-5-16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličin","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 34401A 0 mA CMC 2,0 µA od 0 mA do 10 mA CMC 0,05 % + 2 µA od 10 mA do 100 mA CMC 0,05 % + 5 µA od 0,1 A do 1 A CMC 0,10 % + 1 mA od 1 A do 3 A CMC 0,12 % + 6 mA Stejnosměrný proud Kalibrace – elektrické veličin Porovnání s etalonovým multimetrem 34401A 0 mA CMC 2,0 µA 0 mA až 10 mA CMC 0,05 % + 2 µA 10 mA až 100 mA CMC 0,05 % + 5 µA 0,1 A až 1 A CMC 0,10 % + 1 mA 1 A až 3 A CMC 0,12 % + 6 mA PP-Th 7/1-5-16 Prad staly Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 34401A 0 mA CMC 2,0 µA od 0 mA do 10 mA CMC 0,05 % + 2 µA od 10 mA do 100 mA CMC 0,05 % + 5 µA od 0,1 A do 1 A CMC 0,10 % + 1 mA od 1 A do 3 A CMC 0,12 % + 6 mA Stejnosmerny proud Kalibrace – elektricke velicin Porovnani s etalonovym multimetrem 34401A 0 mA CMC 2,0 µA 0 mA az 10 mA CMC 0,05 % + 2 µA 10 mA az 100 mA CMC 0,05 % + 5 µA 0,1 A az 1 A CMC 0,10 % + 1 mA 1 A az 3 A CMC 0,12 % + 6 mA PP-Th 7/1-5-16","search_en":"Direct current Calibration – electrical quantities Comparison with a standard multimeter 34401A 0 mA CMC 2,0 µA 0 mA to 10 mA CMC 0,05 % + 2 µA 10 mA to 100 mA CMC 0,05 % + 5 µA 0,1 A to 1 A CMC 0,10 % + 1 mA 1 A to 3 A CMC 0,12 % + 6 mA PP-Th 7/1-5-16","search_zh":"直流电流 校准 – 电学量 与标准多用表 34401A 比较 0 mA CMC 2,0 µA 0 mA 至 10 mA CMC 0,05 % + 2 µA 10 mA 至 100 mA CMC 0,05 % + 5 µA 0,1 A 至 1 A CMC 0,10 % + 1 mA 1 A 至 3 A CMC 0,12 % + 6 mA PP-Th 7/1-5-16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b04fa42324d47ac15e23013","lab_id":"6acfffe1ff06824761705e0c","country":"CZ","accr_number":"2305","accr_body":"ČIA","row_label":"3","test_object":"Rezystancja","test_object_en":"Resistance","test_object_zh":"电阻","test_object_cs":"Odpor","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličin","parameters":[{"name":"","range":"0 Ω","cmc":"4 mΩ"},{"name":"","range":"od 0 Ω do 100 Ω","cmc":"0,01 % + 4 mΩ"},{"name":"","range":"od 0,1 kΩ do 1 kΩ","cmc":"0,01 % + 10 mΩ"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"0,01 % + 100 mΩ"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"0,01 % + 1 Ω"}],"parameters_en":[{"name":"","range":"0 Ω","cmc":"4 mΩ"},{"name":"","range":"0 Ω to 100 Ω","cmc":"0,01 % + 4 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,01 % + 10 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,01 % + 100 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,01 % + 1 Ω"}],"parameters_zh":[{"name":"","range":"0 Ω","cmc":"4 mΩ"},{"name":"","range":"0 Ω 至 100 Ω","cmc":"0,01 % + 4 mΩ"},{"name":"","range":"0,1 kΩ 至 1 kΩ","cmc":"0,01 % + 10 mΩ"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"0,01 % + 100 mΩ"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"0,01 % + 1 Ω"}],"parameters_cs":[{"name":"","range":"0 Ω","cmc":"4 mΩ"},{"name":"","range":"0 Ω až 100 Ω","cmc":"0,01 % + 4 mΩ"},{"name":"","range":"0,1 kΩ až 1 kΩ","cmc":"0,01 % + 10 mΩ"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"0,01 % + 100 mΩ"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"0,01 % + 1 Ω"}],"technique":"Porównanie z multimetrem wzorcowym 34401A","technique_en":"Comparison with a standard multimeter 34401A","technique_zh":"与标准多用表 34401A 比较","technique_cs":"Porovnání s etalonovým multimetrem 34401A","techniques":["Porównanie z multimetrem wzorcowym 34401A"],"techniques_en":["Comparison with a standard multimeter 34401A"],"techniques_zh":["与标准多用表 34401A 比较"],"techniques_cs":["Porovnání s etalonovým multimetrem 34401A"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Ω CMC 4 mΩ\nod 0 Ω do 100 Ω CMC 0,01 % + 4 mΩ\nod 0,1 kΩ do 1 kΩ CMC 0,01 % + 10 mΩ\nod 1 kΩ do 10 kΩ CMC 0,01 % + 100 mΩ\nod 10 kΩ do 100 kΩ CMC 0,01 % + 1 Ω\nPorównanie z multimetrem wzorcowym 34401A","reference":"PP-Th 7/1-5-16","norm_bases":["PP-Th 7/1-5-16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličin","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja Wzorcowanie – wielkości elektryczne Porównanie z multimetrem wzorcowym 34401A 0 Ω CMC 4 mΩ od 0 Ω do 100 Ω CMC 0,01 % + 4 mΩ od 0,1 kΩ do 1 kΩ CMC 0,01 % + 10 mΩ od 1 kΩ do 10 kΩ CMC 0,01 % + 100 mΩ od 10 kΩ do 100 kΩ CMC 0,01 % + 1 Ω Odpor Kalibrace – elektrické veličin Porovnání s etalonovým multimetrem 34401A 0 Ω CMC 4 mΩ 0 Ω až 100 Ω CMC 0,01 % + 4 mΩ 0,1 kΩ až 1 kΩ CMC 0,01 % + 10 mΩ 1 kΩ až 10 kΩ CMC 0,01 % + 100 mΩ 10 kΩ až 100 kΩ CMC 0,01 % + 1 Ω PP-Th 7/1-5-16 Rezystancja Wzorcowanie – wielkosci elektryczne Porownanie z multimetrem wzorcowym 34401A 0 Ω CMC 4 mΩ od 0 Ω do 100 Ω CMC 0,01 % + 4 mΩ od 0,1 kΩ do 1 kΩ CMC 0,01 % + 10 mΩ od 1 kΩ do 10 kΩ CMC 0,01 % + 100 mΩ od 10 kΩ do 100 kΩ CMC 0,01 % + 1 Ω Odpor Kalibrace – elektricke velicin Porovnani s etalonovym multimetrem 34401A 0 Ω CMC 4 mΩ 0 Ω az 100 Ω CMC 0,01 % + 4 mΩ 0,1 kΩ az 1 kΩ CMC 0,01 % + 10 mΩ 1 kΩ az 10 kΩ CMC 0,01 % + 100 mΩ 10 kΩ az 100 kΩ CMC 0,01 % + 1 Ω PP-Th 7/1-5-16","search_en":"Resistance Calibration – electrical quantities Comparison with a standard multimeter 34401A 0 Ω CMC 4 mΩ 0 Ω to 100 Ω CMC 0,01 % + 4 mΩ 0,1 kΩ to 1 kΩ CMC 0,01 % + 10 mΩ 1 kΩ to 10 kΩ CMC 0,01 % + 100 mΩ 10 kΩ to 100 kΩ CMC 0,01 % + 1 Ω PP-Th 7/1-5-16","search_zh":"电阻 校准 – 电学量 与标准多用表 34401A 比较 0 Ω CMC 4 mΩ 0 Ω 至 100 Ω CMC 0,01 % + 4 mΩ 0,1 kΩ 至 1 kΩ CMC 0,01 % + 10 mΩ 1 kΩ 至 10 kΩ CMC 0,01 % + 100 mΩ 10 kΩ 至 100 kΩ CMC 0,01 % + 1 Ω PP-Th 7/1-5-16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}