{"lab":{"_id":"6ade8b32ff0682476170810f","accr_number":"2303","country":"CZ","accr_body":"ČIA","address":"Beranových 130, 199 05 Praha 9 - Letňany","categories":["metrology"],"city":"Praha 9","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.5142791,50.1329099]},"map_coord":[50.1329099,14.5142791],"map_geo":"cai-mapa","methods_count":2,"name":"VZLU AEROSPACE, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie siły.","search_text":"vzlu aerospace, a.s. beranových 130, 199 05 praha 9 - letňany 2303","source_page_url":"https://www.cai.cz/?subjekt=2303-vzlu-aerospace-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"12-09-2029","website":"www.vzlu.cz","certificate_date":"10.02.2025","certificate_no":"53/2025","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie siły.","en":"Calibration in the field of force.","zh":"力领域的校准。","cs":"Kalibrace v oboru síla."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"264759e51679819e8a93245f5b727877f3e46dd6309b29dd8e284fdd9b46a3d9","source_pdf_url":"https://www.cai.cz/OA/pdf/P53_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P53_2025_EN.pdf"},"methods":[{"_id":"bc96c3052944519c3bbf64df","lab_id":"6ade8b32ff0682476170810f","country":"CZ","accr_number":"2303","accr_body":"ČIA","row_label":"1","test_object":"Siłomierze tensometryczne","test_object_en":"Load cell","test_object_zh":"应变式测力计","test_object_cs":"Tenzometrické siloměry","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"rozciąganie, ściskanie","range":"od 0,1 kN do 500 kN","cmc":"0,05 %"}],"parameters_en":[{"name":"Tension, Compression","range":"0,1 kN to 500 kN","cmc":"0,05 %"}],"parameters_zh":[{"name":"拉力、压力","range":"0,1 kN 至 500 kN","cmc":"0,05 %"}],"parameters_cs":[{"name":"tah, tlak","range":"0,1 kN až 500 kN","cmc":"0,05 %"}],"technique":"Pomiar za pomocą przetwornika siły","technique_en":"Measurement by force of load cell","technique_zh":"用力传感器测量","technique_cs":"Měření pomocí snímače síly","techniques":["Pomiar za pomocą przetwornika siły"],"techniques_en":["Measurement by force of load cell"],"techniques_zh":["用力传感器测量"],"techniques_cs":["Měření pomocí snímače síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nrozciąganie, ściskanie od 0,1 kN do 500 kN CMC 0,05 %\nPomiar za pomocą przetwornika siły","reference":"PP-SVŘ-034 (ČSN EN ISO 376)","norm_bases":["PP-SVŘ-034","ČSN EN ISO 376"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Siłomierze tensometryczne Wzorcowanie – siła Pomiar za pomocą przetwornika siły rozciąganie, ściskanie od 0,1 kN do 500 kN CMC 0,05 % Tenzometrické siloměry Kalibrace – síla Měření pomocí snímače síly tah, tlak 0,1 kN až 500 kN CMC 0,05 % PP-SVŘ-034 (ČSN EN ISO 376) Silomierze tensometryczne Wzorcowanie – sila Pomiar za pomoca przetwornika sily rozciaganie, sciskanie od 0,1 kN do 500 kN CMC 0,05 % Tenzometricke silomery Kalibrace – sila Mereni pomoci snimace sily tah, tlak 0,1 kN az 500 kN CMC 0,05 % PP-SVR-034 (CSN EN ISO 376)","search_en":"Load cell Calibration – force Measurement by force of load cell Tension, Compression 0,1 kN to 500 kN CMC 0,05 % PP-SVŘ-034 (ČSN EN ISO 376)","search_zh":"应变式测力计 校准 – 力 用力传感器测量 拉力、压力 0,1 kN 至 500 kN CMC 0,05 % PP-SVŘ-034 (ČSN EN ISO 376)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"51689fae62644863a2e8476a","lab_id":"6ade8b32ff0682476170810f","country":"CZ","accr_number":"2303","accr_body":"ČIA","row_label":"2","test_object":"Maszyny do badań mechanicznych materiałów","test_object_en":"Machines for mechanical testing of materials","test_object_zh":"材料力学试验机","test_object_cs":"Stroje pro mechanické zkoušky materiálu","methodology":"Wzorcowanie – siła","methodology_en":"Calibration – force","methodology_zh":"校准 – 力","methodology_cs":"Kalibrace – síla","parameters":[{"name":"rozciąganie, ściskanie","range":"od 0,1 kN do 500 kN","cmc":"0,05 %"}],"parameters_en":[{"name":"Tension, Compression","range":"0,1 kN to 500 kN","cmc":"0,05 %"}],"parameters_zh":[{"name":"拉力、压力","range":"0,1 kN 至 500 kN","cmc":"0,05 %"}],"parameters_cs":[{"name":"tah, tlak","range":"0,1 kN až 500 kN","cmc":"0,05 %"}],"technique":"Pomiar za pomocą przetwornika siły","technique_en":"Measurement by force of load cell","technique_zh":"用力传感器测量","technique_cs":"Měření pomocí snímače síly","techniques":["Pomiar za pomocą przetwornika siły"],"techniques_en":["Measurement by force of load cell"],"techniques_zh":["用力传感器测量"],"techniques_cs":["Měření pomocí snímače síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – siła\nrozciąganie, ściskanie od 0,1 kN do 500 kN CMC 0,05 %\nPomiar za pomocą przetwornika siły","reference":"PP-SVŘ-029 (ČSN EN ISO 7500-1)","norm_bases":["PP-SVŘ-029","ČSN EN ISO 7500-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: siła","regulatory_area_en":"CMC for the field of measured quantity: Force","regulatory_area_zh":"被测量领域的CMC：力","regulatory_area_cs":"CMC pro obor měřené veličiny: Síla","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny do badań mechanicznych materiałów Wzorcowanie – siła Pomiar za pomocą przetwornika siły rozciąganie, ściskanie od 0,1 kN do 500 kN CMC 0,05 % Stroje pro mechanické zkoušky materiálu Kalibrace – síla Měření pomocí snímače síly tah, tlak 0,1 kN až 500 kN CMC 0,05 % PP-SVŘ-029 (ČSN EN ISO 7500-1) Maszyny do badan mechanicznych materialow Wzorcowanie – sila Pomiar za pomoca przetwornika sily rozciaganie, sciskanie od 0,1 kN do 500 kN CMC 0,05 % Stroje pro mechanicke zkousky materialu Kalibrace – sila Mereni pomoci snimace sily tah, tlak 0,1 kN az 500 kN CMC 0,05 % PP-SVR-029 (CSN EN ISO 7500-1)","search_en":"Machines for mechanical testing of materials Calibration – force Measurement by force of load cell Tension, Compression 0,1 kN to 500 kN CMC 0,05 % PP-SVŘ-029 (ČSN EN ISO 7500-1)","search_zh":"材料力学试验机 校准 – 力 用力传感器测量 拉力、压力 0,1 kN 至 500 kN CMC 0,05 % PP-SVŘ-029 (ČSN EN ISO 7500-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}