{"lab":{"_id":"6acfffe1ff06824761705e0b","accr_number":"2298","country":"CZ","accr_body":"ČIA","address":"Toužimská 897/E/3, 199 00 Praha 18 – Letňany","categories":["metrology"],"city":"Praha 18 – Letňany","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.52491,50.138614]},"map_coord":[50.138614,14.52491],"map_geo":"nominatim-street","methods_count":6,"name":"JD Dvořák, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów do pomiaru temperatury i wilgotności.","search_text":"jd dvořák, s.r.o. toužimská 897/e/3, 199 00 praha 18 – letňany 2298","source_page_url":"https://www.cai.cz/?subjekt=2298-jd-dvorak-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"26-04-2029","website":"www.testsysteme.cz","certificate_date":"26.04.2024","certificate_no":"190/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów do pomiaru temperatury i wilgotności.","en":"Calibration of temperature and humidity meters.","zh":"温度和湿度测量器具的校准。","cs":"Kalibrace měřidel teploty a vlhkosti."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"JD Dvořák, s.r.o., laboratorium wzorcujące","lab_division_cs":"JD Dvořák, s.r.o., kalibrační laboratoř","lab_division_en":"JD Dvořák, s.r.o., calibration laboratory","lab_division_zh":"JD Dvořák, s.r.o. 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"72d767ccd9610e821b2fd5c05f6324d7f4eb0ed04f28e6fdc3eb5f22aa993689","source_pdf_url":"https://www.cai.cz/OA/pdf/P190_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P190_2024_EN.pdf"},"methods":[{"_id":"231be5e3d492f8671878057f","lab_id":"6acfffe1ff06824761705e0b","country":"CZ","accr_number":"2298","accr_body":"ČIA","row_label":"1","test_object":"Termometry jako część torów pomiarowych komór i szaf termicznych i klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć temperaturę","test_object_en":"Thermometers integrated in measuring chains of thermal and climatic chambers and enclosures and special-purpose enclosures, where temperature can be generated","test_object_zh":"热箱、气候箱和柜以及可产生温度的专用柜测量链中的温度计","test_object_cs":"Teploměry jako součást měřících řetězců teplotních a klimatických komor a skříní, a skříní pro speciální použití, kde lze generovat teplotu","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od - 70 °C do - 45 °C","cmc":"0,20 °C"},{"name":"","range":"od - 45 °C do 100 °C","cmc":"0,17 °C"},{"name":"","range":"od 100 °C do 200 °C","cmc":"0,21 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"0,9 °C"},{"name":"","range":"od 300 °C do 400 °C","cmc":"1,1 °C"}],"parameters_en":[{"name":"","range":"- 70 °C to - 45 °C","cmc":"0,20 °C"},{"name":"","range":"- 45 °C to 100 °C","cmc":"0,17 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,21 °C"},{"name":"","range":"200 °C to 300 °C","cmc":"0,9 °C"},{"name":"","range":"300 °C to 400 °C","cmc":"1,1 °C"}],"parameters_zh":[{"name":"","range":"- 70 °C 至 - 45 °C","cmc":"0,20 °C"},{"name":"","range":"- 45 °C 至 100 °C","cmc":"0,17 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,21 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"0,9 °C"},{"name":"","range":"300 °C 至 400 °C","cmc":"1,1 °C"}],"parameters_cs":[{"name":"","range":"- 70 °C až - 45 °C","cmc":"0,20 °C"},{"name":"","range":"- 45 °C až 100 °C","cmc":"0,17 °C"},{"name":"","range":"100 °C až 200 °C","cmc":"0,21 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"0,9 °C"},{"name":"","range":"300 °C až 400 °C","cmc":"1,1 °C"}],"technique":"Porównanie z termometrem wzorcowym w środowisku gazowym","technique_en":"Comparison with a reference thermometer in a gaseous environment","technique_zh":"在气体环境中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v plynném prostředí","techniques":["Porównanie z termometrem wzorcowym w środowisku gazowym"],"techniques_en":["Comparison with a reference thermometer in a gaseous environment"],"techniques_zh":["在气体环境中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v plynném prostředí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod - 70 °C do - 45 °C CMC 0,20 °C\nod - 45 °C do 100 °C CMC 0,17 °C\nod 100 °C do 200 °C CMC 0,21 °C\nod 200 °C do 300 °C CMC 0,9 °C\nod 300 °C do 400 °C CMC 1,1 °C\nPorównanie z termometrem wzorcowym w środowisku gazowym","reference":"Interní metoda 1 (DKD-R_5.7 metoda C)","norm_bases":["Interní metoda 1","DKD-R_5.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry jako część torów pomiarowych komór i szaf termicznych i klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć temperaturę Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w środowisku gazowym od - 70 °C do - 45 °C CMC 0,20 °C od - 45 °C do 100 °C CMC 0,17 °C od 100 °C do 200 °C CMC 0,21 °C od 200 °C do 300 °C CMC 0,9 °C od 300 °C do 400 °C CMC 1,1 °C Teploměry jako součást měřících řetězců teplotních a klimatických komor a skříní, a skříní pro speciální použití, kde lze generovat teplotu Kalibrace – teplota Porovnání s etalonovým teploměrem v plynném prostředí - 70 °C až - 45 °C CMC 0,20 °C - 45 °C až 100 °C CMC 0,17 °C 100 °C až 200 °C CMC 0,21 °C 200 °C až 300 °C CMC 0,9 °C 300 °C až 400 °C CMC 1,1 °C Interní metoda 1 (DKD-R_5.7 metoda C) Termometry jako czesc torow pomiarowych komor i szaf termicznych i klimatycznych oraz szaf specjalnego przeznaczenia, w ktorych mozna wytworzyc temperature Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w srodowisku gazowym od - 70 °C do - 45 °C CMC 0,20 °C od - 45 °C do 100 °C CMC 0,17 °C od 100 °C do 200 °C CMC 0,21 °C od 200 °C do 300 °C CMC 0,9 °C od 300 °C do 400 °C CMC 1,1 °C Teplomery jako soucast mericich retezcu teplotnich a klimatickych komor a skrini, a skrini pro specialni pouziti, kde lze generovat teplotu Kalibrace – teplota Porovnani s etalonovym teplomerem v plynnem prostredi - 70 °C az - 45 °C CMC 0,20 °C - 45 °C az 100 °C CMC 0,17 °C 100 °C az 200 °C CMC 0,21 °C 200 °C az 300 °C CMC 0,9 °C 300 °C az 400 °C CMC 1,1 °C Interni metoda 1 (DKD-R_5.7 metoda C)","search_en":"Thermometers integrated in measuring chains of thermal and climatic chambers and enclosures and special-purpose enclosures, where temperature can be generated Calibration – temperature Comparison with a reference thermometer in a gaseous environment - 70 °C to - 45 °C CMC 0,20 °C - 45 °C to 100 °C CMC 0,17 °C 100 °C to 200 °C CMC 0,21 °C 200 °C to 300 °C CMC 0,9 °C 300 °C to 400 °C CMC 1,1 °C Interní metoda 1 (DKD-R_5.7 metoda C)","search_zh":"热箱、气候箱和柜以及可产生温度的专用柜测量链中的温度计 校准 – 温度 在气体环境中与标准温度计比较 - 70 °C 至 - 45 °C CMC 0,20 °C - 45 °C 至 100 °C CMC 0,17 °C 100 °C 至 200 °C CMC 0,21 °C 200 °C 至 300 °C CMC 0,9 °C 300 °C 至 400 °C CMC 1,1 °C Interní metoda 1 (DKD-R_5.7 metoda C)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"776fc5ebfdf5d6fc6efab7ef","lab_id":"6acfffe1ff06824761705e0b","country":"CZ","accr_number":"2298","accr_body":"ČIA","row_label":"2","test_object":"Termometry jako część torów pomiarowych komór i szaf termicznych i klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć temperaturę","test_object_en":"Thermometers integrated in measuring chains of thermal and climatic chambers and enclosures and special-purpose enclosures, where temperature can be generated","test_object_zh":"热箱、气候箱和柜以及可产生温度的专用柜测量链中的温度计","test_object_cs":"Teploměry jako součást měřících řetězců teplotních a klimatických komor a skříní, a skříní pro speciální použití, kde lze generovat teplotu","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od - 70 °C do - 45 °C","cmc":"0,35 °C"},{"name":"","range":"od - 45 °C do 100 °C","cmc":"0,27 °C"},{"name":"","range":"od 100 °C do 150 °C","cmc":"0,37 °C"},{"name":"","range":"od 150 °C do 180 °C","cmc":"0,75 °C"}],"parameters_en":[{"name":"","range":"- 70 °C to - 45 °C","cmc":"0,35 °C"},{"name":"","range":"- 45 °C to 100 °C","cmc":"0,27 °C"},{"name":"","range":"100 °C to 150 °C","cmc":"0,37 °C"},{"name":"","range":"150 °C to 180 °C","cmc":"0,75 °C"}],"parameters_zh":[{"name":"","range":"- 70 °C 至 - 45 °C","cmc":"0,35 °C"},{"name":"","range":"- 45 °C 至 100 °C","cmc":"0,27 °C"},{"name":"","range":"100 °C 至 150 °C","cmc":"0,37 °C"},{"name":"","range":"150 °C 至 180 °C","cmc":"0,75 °C"}],"parameters_cs":[{"name":"","range":"- 70 °C až - 45 °C","cmc":"0,35 °C"},{"name":"","range":"- 45 °C až 100 °C","cmc":"0,27 °C"},{"name":"","range":"100 °C až 150 °C","cmc":"0,37 °C"},{"name":"","range":"150 °C až 180 °C","cmc":"0,75 °C"}],"technique":"Porównanie z termometrem wzorcowym w środowisku gazowym","technique_en":"Comparison with a reference thermometer in a gaseous environment","technique_zh":"在气体环境中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v plynném prostředí","techniques":["Porównanie z termometrem wzorcowym w środowisku gazowym"],"techniques_en":["Comparison with a reference thermometer in a gaseous environment"],"techniques_zh":["在气体环境中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v plynném prostředí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod - 70 °C do - 45 °C CMC 0,35 °C\nod - 45 °C do 100 °C CMC 0,27 °C\nod 100 °C do 150 °C CMC 0,37 °C\nod 150 °C do 180 °C CMC 0,75 °C\nPorównanie z termometrem wzorcowym w środowisku gazowym","reference":"Interní metoda 3 (DKD-R_5.7 metoda A a B)","norm_bases":["Interní metoda 3","DKD-R_5.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry jako część torów pomiarowych komór i szaf termicznych i klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć temperaturę Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w środowisku gazowym od - 70 °C do - 45 °C CMC 0,35 °C od - 45 °C do 100 °C CMC 0,27 °C od 100 °C do 150 °C CMC 0,37 °C od 150 °C do 180 °C CMC 0,75 °C Teploměry jako součást měřících řetězců teplotních a klimatických komor a skříní, a skříní pro speciální použití, kde lze generovat teplotu Kalibrace – teplota Porovnání s etalonovým teploměrem v plynném prostředí - 70 °C až - 45 °C CMC 0,35 °C - 45 °C až 100 °C CMC 0,27 °C 100 °C až 150 °C CMC 0,37 °C 150 °C až 180 °C CMC 0,75 °C Interní metoda 3 (DKD-R_5.7 metoda A a B) Termometry jako czesc torow pomiarowych komor i szaf termicznych i klimatycznych oraz szaf specjalnego przeznaczenia, w ktorych mozna wytworzyc temperature Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w srodowisku gazowym od - 70 °C do - 45 °C CMC 0,35 °C od - 45 °C do 100 °C CMC 0,27 °C od 100 °C do 150 °C CMC 0,37 °C od 150 °C do 180 °C CMC 0,75 °C Teplomery jako soucast mericich retezcu teplotnich a klimatickych komor a skrini, a skrini pro specialni pouziti, kde lze generovat teplotu Kalibrace – teplota Porovnani s etalonovym teplomerem v plynnem prostredi - 70 °C az - 45 °C CMC 0,35 °C - 45 °C az 100 °C CMC 0,27 °C 100 °C az 150 °C CMC 0,37 °C 150 °C az 180 °C CMC 0,75 °C Interni metoda 3 (DKD-R_5.7 metoda A a B)","search_en":"Thermometers integrated in measuring chains of thermal and climatic chambers and enclosures and special-purpose enclosures, where temperature can be generated Calibration – temperature Comparison with a reference thermometer in a gaseous environment - 70 °C to - 45 °C CMC 0,35 °C - 45 °C to 100 °C CMC 0,27 °C 100 °C to 150 °C CMC 0,37 °C 150 °C to 180 °C CMC 0,75 °C Interní metoda 3 (DKD-R_5.7 metoda A a B)","search_zh":"热箱、气候箱和柜以及可产生温度的专用柜测量链中的温度计 校准 – 温度 在气体环境中与标准温度计比较 - 70 °C 至 - 45 °C CMC 0,35 °C - 45 °C 至 100 °C CMC 0,27 °C 100 °C 至 150 °C CMC 0,37 °C 150 °C 至 180 °C CMC 0,75 °C Interní metoda 3 (DKD-R_5.7 metoda A a B)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"134adf5c36bf6ba59720066d","lab_id":"6acfffe1ff06824761705e0b","country":"CZ","accr_number":"2298","accr_body":"ČIA","row_label":"3","test_object":"Elektroniczne termometry bezpośrednio wskazujące, termometry do pomiaru temperatury powietrza, tory pomiarowe temperatury, rejestratory danych, termometry zewnętrzne","test_object_en":"Direct indication electronic thermometers, thermometers for air temperature measurement, temperature measuring chains, data loggers, outdoor thermometers","test_object_zh":"直读式电子温度计、空气温度计、温度测量链、数据记录器、室外温度计","test_object_cs":"Přímo ukazující elektronické teploměry, teploměry pro měření teploty vzduchu, měřící řetězce pro měření teploty, datalogery, venkovní teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od - 70 °C do 0 °C","cmc":"0,45 °C"},{"name":"","range":"od 0 °C do 100 °C","cmc":"0,36 °C"},{"name":"","range":"od 100 °C do 150 °C","cmc":"0,57 °C"},{"name":"","range":"od 150 °C do 180 °C","cmc":"1,0 °C"}],"parameters_en":[{"name":"","range":"- 70 °C to 0 °C","cmc":"0,45 °C"},{"name":"","range":"0 °C to 100 °C","cmc":"0,36 °C"},{"name":"","range":"100 °C to 150 °C","cmc":"0,57 °C"},{"name":"","range":"150 °C to 180 °C","cmc":"1,0 °C"}],"parameters_zh":[{"name":"","range":"- 70 °C 至 0 °C","cmc":"0,45 °C"},{"name":"","range":"0 °C 至 100 °C","cmc":"0,36 °C"},{"name":"","range":"100 °C 至 150 °C","cmc":"0,57 °C"},{"name":"","range":"150 °C 至 180 °C","cmc":"1,0 °C"}],"parameters_cs":[{"name":"","range":"- 70 °C až 0 °C","cmc":"0,45 °C"},{"name":"","range":"0 °C až 100 °C","cmc":"0,36 °C"},{"name":"","range":"100 °C až 150 °C","cmc":"0,57 °C"},{"name":"","range":"150 °C až 180 °C","cmc":"1,0 °C"}],"technique":"Porównanie z termometrem wzorcowym w komorze klimatycznej","technique_en":"Comparison with a standard thermometer in a climatic chamber","technique_zh":"在气候箱中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v klimatické komoře","techniques":["Porównanie z termometrem wzorcowym w komorze klimatycznej"],"techniques_en":["Comparison with a standard thermometer in a climatic chamber"],"techniques_zh":["在气候箱中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod - 70 °C do 0 °C CMC 0,45 °C\nod 0 °C do 100 °C CMC 0,36 °C\nod 100 °C do 150 °C CMC 0,57 °C\nod 150 °C do 180 °C CMC 1,0 °C\nPorównanie z termometrem wzorcowym w komorze klimatycznej","reference":"Interní metoda 5","norm_bases":["Interní metoda 5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Elektroniczne termometry bezpośrednio wskazujące, termometry do pomiaru temperatury powietrza, tory pomiarowe temperatury, rejestratory danych, termometry zewnętrzne Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w komorze klimatycznej od - 70 °C do 0 °C CMC 0,45 °C od 0 °C do 100 °C CMC 0,36 °C od 100 °C do 150 °C CMC 0,57 °C od 150 °C do 180 °C CMC 1,0 °C Přímo ukazující elektronické teploměry, teploměry pro měření teploty vzduchu, měřící řetězce pro měření teploty, datalogery, venkovní teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem v klimatické komoře - 70 °C až 0 °C CMC 0,45 °C 0 °C až 100 °C CMC 0,36 °C 100 °C až 150 °C CMC 0,57 °C 150 °C až 180 °C CMC 1,0 °C Interní metoda 5 Elektroniczne termometry bezposrednio wskazujace, termometry do pomiaru temperatury powietrza, tory pomiarowe temperatury, rejestratory danych, termometry zewnetrzne Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w komorze klimatycznej od - 70 °C do 0 °C CMC 0,45 °C od 0 °C do 100 °C CMC 0,36 °C od 100 °C do 150 °C CMC 0,57 °C od 150 °C do 180 °C CMC 1,0 °C Primo ukazujici elektronicke teplomery, teplomery pro mereni teploty vzduchu, merici retezce pro mereni teploty, datalogery, venkovni teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem v klimaticke komore - 70 °C az 0 °C CMC 0,45 °C 0 °C az 100 °C CMC 0,36 °C 100 °C az 150 °C CMC 0,57 °C 150 °C az 180 °C CMC 1,0 °C Interni metoda 5","search_en":"Direct indication electronic thermometers, thermometers for air temperature measurement, temperature measuring chains, data loggers, outdoor thermometers Calibration – temperature Comparison with a standard thermometer in a climatic chamber - 70 °C to 0 °C CMC 0,45 °C 0 °C to 100 °C CMC 0,36 °C 100 °C to 150 °C CMC 0,57 °C 150 °C to 180 °C CMC 1,0 °C Interní metoda 5","search_zh":"直读式电子温度计、空气温度计、温度测量链、数据记录器、室外温度计 校准 – 温度 在气候箱中与标准温度计比较 - 70 °C 至 0 °C CMC 0,45 °C 0 °C 至 100 °C CMC 0,36 °C 100 °C 至 150 °C CMC 0,57 °C 150 °C 至 180 °C CMC 1,0 °C Interní metoda 5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be17ffd9c36e3fb07f1607ab","lab_id":"6acfffe1ff06824761705e0b","country":"CZ","accr_number":"2298","accr_body":"ČIA","row_label":"1","test_object":"Wilgotnościomierze jako część torów pomiarowych komór i szaf klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć wilgotność i temperaturę","test_object_en":"Hygrometers integrated in measuring chains of climatic chambers and enclosures and special-purpose enclosures, where humidity and temperature can be generated","test_object_zh":"气候箱和柜以及可产生湿度和温度的专用柜测量链中的湿度计","test_object_cs":"Vlhkoměry jako součást měřících řetězců klimatických komor a skříní, a skříní pro speciální účely, kde lze generovat vlhkost a teplotu","methodology":"Wzorcowanie – wilgotność względna","methodology_en":"Calibration – relative humidity","methodology_zh":"校准 – 相对湿度","methodology_cs":"Kalibrace – relativní vlhkost","parameters":[{"name":"(10 – 20) °C","range":"od 10 % RH do 30 % RH","cmc":"1,7 % RH"},{"name":"(10 – 20) °C","range":"od 30 % RH do 95 % RH","cmc":"2,3 % RH"},{"name":"(20 – 90) °C","range":"od 10 % RH do 30 % RH","cmc":"1,5 % RH"},{"name":"(20 – 90) °C","range":"od 30 % RH do 95 % RH","cmc":"1,9 % RH"},{"name":"(90 – 95) °C","range":"od 10 % RH do 30 % RH","cmc":"1,4 % RH"},{"name":"(90 – 95) °C","range":"od 30 % RH do 95 % RH","cmc":"1,6 % RH"}],"parameters_en":[{"name":"(10 to 20) °C","range":"10 % RH to 30 % RH","cmc":"1,7 % RH"},{"name":"(10 to 20) °C","range":"30 % RH to 95 % RH","cmc":"2,3 % RH"},{"name":"(20 to 90) °C","range":"10 % RH to 30 % RH","cmc":"1,5 % RH"},{"name":"(20 to 90) °C","range":"30 % RH to 95 % RH","cmc":"1,9 % RH"},{"name":"(90 to 95) °C","range":"10 % RH to 30 % RH","cmc":"1,4 % RH"},{"name":"(90 to 95) °C","range":"30 % RH to 95 % RH","cmc":"1,6 % RH"}],"parameters_zh":[{"name":"(10 - 20) °C","range":"10 % RH 至 30 % RH","cmc":"1,7 % RH"},{"name":"(10 - 20) °C","range":"30 % RH 至 95 % RH","cmc":"2,3 % RH"},{"name":"(20 - 90) °C","range":"10 % RH 至 30 % RH","cmc":"1,5 % RH"},{"name":"(20 - 90) °C","range":"30 % RH 至 95 % RH","cmc":"1,9 % RH"},{"name":"(90 - 95) °C","range":"10 % RH 至 30 % RH","cmc":"1,4 % RH"},{"name":"(90 - 95) °C","range":"30 % RH 至 95 % RH","cmc":"1,6 % RH"}],"parameters_cs":[{"name":"(10 - 20) °C","range":"10 % RH až 30 % RH","cmc":"1,7 % RH"},{"name":"(10 - 20) °C","range":"30 % RH až 95 % RH","cmc":"2,3 % RH"},{"name":"(20 - 90) °C","range":"10 % RH až 30 % RH","cmc":"1,5 % RH"},{"name":"(20 - 90) °C","range":"30 % RH až 95 % RH","cmc":"1,9 % RH"},{"name":"(90 - 95) °C","range":"10 % RH až 30 % RH","cmc":"1,4 % RH"},{"name":"(90 - 95) °C","range":"30 % RH až 95 % RH","cmc":"1,6 % RH"}],"technique":"Porównanie z wzorcowym psychrometrem aspiracyjnym","technique_en":"Comparison with a standard aspiration hygrometer","technique_zh":"与标准通风湿度计比较","technique_cs":"Porovnání s etalonovým aspiračním vlhkoměrem","techniques":["Porównanie z wzorcowym psychrometrem aspiracyjnym"],"techniques_en":["Comparison with a standard aspiration hygrometer"],"techniques_zh":["与标准通风湿度计比较"],"techniques_cs":["Porovnání s etalonovým aspiračním vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność względna\nZakres:\n(10 – 20) °C od 10 % RH do 30 % RH CMC 1,7 % RH\n(10 – 20) °C od 30 % RH do 95 % RH CMC 2,3 % RH\n(20 – 90) °C od 10 % RH do 30 % RH CMC 1,5 % RH\n(20 – 90) °C od 30 % RH do 95 % RH CMC 1,9 % RH\n(90 – 95) °C od 10 % RH do 30 % RH CMC 1,4 % RH\n(90 – 95) °C od 30 % RH do 95 % RH CMC 1,6 % RH\nPorównanie z wzorcowym psychrometrem aspiracyjnym","reference":"Interní metoda 2 (DKD-R_5.7 metoda C)","norm_bases":["Interní metoda 2","DKD-R_5.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność względna","regulatory_area_en":"CMC for the field of measured quantity: Relative humidity","regulatory_area_zh":"被测量领域的CMC：相对湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Relativní vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotnościomierze jako część torów pomiarowych komór i szaf klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć wilgotność i temperaturę Wzorcowanie – wilgotność względna Porównanie z wzorcowym psychrometrem aspiracyjnym (10 – 20) °C od 10 % RH do 30 % RH CMC 1,7 % RH (10 – 20) °C od 30 % RH do 95 % RH CMC 2,3 % RH (20 – 90) °C od 10 % RH do 30 % RH CMC 1,5 % RH (20 – 90) °C od 30 % RH do 95 % RH CMC 1,9 % RH (90 – 95) °C od 10 % RH do 30 % RH CMC 1,4 % RH (90 – 95) °C od 30 % RH do 95 % RH CMC 1,6 % RH Vlhkoměry jako součást měřících řetězců klimatických komor a skříní, a skříní pro speciální účely, kde lze generovat vlhkost a teplotu Kalibrace – relativní vlhkost Porovnání s etalonovým aspiračním vlhkoměrem (10 - 20) °C 10 % RH až 30 % RH CMC 1,7 % RH (10 - 20) °C 30 % RH až 95 % RH CMC 2,3 % RH (20 - 90) °C 10 % RH až 30 % RH CMC 1,5 % RH (20 - 90) °C 30 % RH až 95 % RH CMC 1,9 % RH (90 - 95) °C 10 % RH až 30 % RH CMC 1,4 % RH (90 - 95) °C 30 % RH až 95 % RH CMC 1,6 % RH Interní metoda 2 (DKD-R_5.7 metoda C) Wilgotnosciomierze jako czesc torow pomiarowych komor i szaf klimatycznych oraz szaf specjalnego przeznaczenia, w ktorych mozna wytworzyc wilgotnosc i temperature Wzorcowanie – wilgotnosc wzgledna Porownanie z wzorcowym psychrometrem aspiracyjnym (10 – 20) °C od 10 % RH do 30 % RH CMC 1,7 % RH (10 – 20) °C od 30 % RH do 95 % RH CMC 2,3 % RH (20 – 90) °C od 10 % RH do 30 % RH CMC 1,5 % RH (20 – 90) °C od 30 % RH do 95 % RH CMC 1,9 % RH (90 – 95) °C od 10 % RH do 30 % RH CMC 1,4 % RH (90 – 95) °C od 30 % RH do 95 % RH CMC 1,6 % RH Vlhkomery jako soucast mericich retezcu klimatickych komor a skrini, a skrini pro specialni ucely, kde lze generovat vlhkost a teplotu Kalibrace – relativni vlhkost Porovnani s etalonovym aspiracnim vlhkomerem (10 - 20) °C 10 % RH az 30 % RH CMC 1,7 % RH (10 - 20) °C 30 % RH az 95 % RH CMC 2,3 % RH (20 - 90) °C 10 % RH az 30 % RH CMC 1,5 % RH (20 - 90) °C 30 % RH az 95 % RH CMC 1,9 % RH (90 - 95) °C 10 % RH az 30 % RH CMC 1,4 % RH (90 - 95) °C 30 % RH az 95 % RH CMC 1,6 % RH Interni metoda 2 (DKD-R_5.7 metoda C)","search_en":"Hygrometers integrated in measuring chains of climatic chambers and enclosures and special-purpose enclosures, where humidity and temperature can be generated Calibration – relative humidity Comparison with a standard aspiration hygrometer (10 to 20) °C 10 % RH to 30 % RH CMC 1,7 % RH (10 to 20) °C 30 % RH to 95 % RH CMC 2,3 % RH (20 to 90) °C 10 % RH to 30 % RH CMC 1,5 % RH (20 to 90) °C 30 % RH to 95 % RH CMC 1,9 % RH (90 to 95) °C 10 % RH to 30 % RH CMC 1,4 % RH (90 to 95) °C 30 % RH to 95 % RH CMC 1,6 % RH Interní metoda 2 (DKD-R_5.7 metoda C)","search_zh":"气候箱和柜以及可产生湿度和温度的专用柜测量链中的湿度计 校准 – 相对湿度 与标准通风湿度计比较 (10 - 20) °C 10 % RH 至 30 % RH CMC 1,7 % RH (10 - 20) °C 30 % RH 至 95 % RH CMC 2,3 % RH (20 - 90) °C 10 % RH 至 30 % RH CMC 1,5 % RH (20 - 90) °C 30 % RH 至 95 % RH CMC 1,9 % RH (90 - 95) °C 10 % RH 至 30 % RH CMC 1,4 % RH (90 - 95) °C 30 % RH 至 95 % RH CMC 1,6 % RH Interní metoda 2 (DKD-R_5.7 metoda C)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6bf2e16e0e068a1171873aaa","lab_id":"6acfffe1ff06824761705e0b","country":"CZ","accr_number":"2298","accr_body":"ČIA","row_label":"2","test_object":"Wilgotnościomierze jako część torów pomiarowych komór i szaf klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć wilgotność i temperaturę","test_object_en":"Hygrometers integrated in measuring chains of climatic chambers and enclosures and special-purpose enclosures, where humidity and temperature can be generated","test_object_zh":"气候箱和柜以及可产生湿度和温度的专用柜测量链中的湿度计","test_object_cs":"Vlhkoměry jako součást měřících řetězců klimatických komor a skříní, a skříní pro speciální účely, kde lze generovat vlhkost a teplotu","methodology":"Wzorcowanie – wilgotność względna","methodology_en":"Calibration – relative humidity","methodology_zh":"校准 – 相对湿度","methodology_cs":"Kalibrace – relativní vlhkost","parameters":[{"name":"(10 – 20) °C","range":"od 10 % RH do 30 % RH","cmc":"1,8 % RH"},{"name":"(10 – 20) °C","range":"od 30 % RH do 95 % RH","cmc":"2,4 % RH"},{"name":"(20 – 90) °C","range":"od 10 % RH do 30 % RH","cmc":"1,6 % RH"},{"name":"(20 – 90) °C","range":"od 30 % RH do 95 % RH","cmc":"2,0 % RH"},{"name":"(90 – 95) °C","range":"od 10 % RH do 30 % RH","cmc":"1,5 % RH"},{"name":"(90 – 95) °C","range":"od 30 % RH do 95 % RH","cmc":"1,7 % RH"}],"parameters_en":[{"name":"(10 to 20) °C","range":"10 % RH to 30 % RH","cmc":"1,8 % RH"},{"name":"(10 to 20) °C","range":"30 % RH to 95 % RH","cmc":"2,4 % RH"},{"name":"(20 to 90) °C","range":"10 % RH to 30 % RH","cmc":"1,6 % RH"},{"name":"(20 to 90) °C","range":"30 % RH to 95 % RH","cmc":"2,0 % RH"},{"name":"(90 to 95) °C","range":"10 % RH to 30 % RH","cmc":"1,5 % RH"},{"name":"(90 to 95) °C","range":"30 % RH to 95 % RH","cmc":"1,7 % RH"}],"parameters_zh":[{"name":"(10 - 20) °C","range":"10 % RH 至 30 % RH","cmc":"1,8 % RH"},{"name":"(10 - 20) °C","range":"30 % RH 至 95 % RH","cmc":"2,4 % RH"},{"name":"(20 - 90) °C","range":"10 % RH 至 30 % RH","cmc":"1,6 % RH"},{"name":"(20 - 90) °C","range":"30 % RH 至 95 % RH","cmc":"2,0 % RH"},{"name":"(90 - 95) °C","range":"10 % RH 至 30 % RH","cmc":"1,5 % RH"},{"name":"(90 - 95) °C","range":"30 % RH 至 95 % RH","cmc":"1,7 % RH"}],"parameters_cs":[{"name":"(10 - 20) °C","range":"10 % RH až 30 % RH","cmc":"1,8 % RH"},{"name":"(10 - 20) °C","range":"30 % RH až 95 % RH","cmc":"2,4 % RH"},{"name":"(20 - 90) °C","range":"10 % RH až 30 % RH","cmc":"1,6 % RH"},{"name":"(20 - 90) °C","range":"30 % RH až 95 % RH","cmc":"2,0 % RH"},{"name":"(90 - 95) °C","range":"10 % RH až 30 % RH","cmc":"1,5 % RH"},{"name":"(90 - 95) °C","range":"30 % RH až 95 % RH","cmc":"1,7 % RH"}],"technique":"Porównanie z wzorcowym psychrometrem aspiracyjnym","technique_en":"Comparison with a standard aspiration hygrometer","technique_zh":"与标准通风湿度计比较","technique_cs":"Porovnání s etalonovým aspiračním vlhkoměrem","techniques":["Porównanie z wzorcowym psychrometrem aspiracyjnym"],"techniques_en":["Comparison with a standard aspiration hygrometer"],"techniques_zh":["与标准通风湿度计比较"],"techniques_cs":["Porovnání s etalonovým aspiračním vlhkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność względna\nZakres:\n(10 – 20) °C od 10 % RH do 30 % RH CMC 1,8 % RH\n(10 – 20) °C od 30 % RH do 95 % RH CMC 2,4 % RH\n(20 – 90) °C od 10 % RH do 30 % RH CMC 1,6 % RH\n(20 – 90) °C od 30 % RH do 95 % RH CMC 2,0 % RH\n(90 – 95) °C od 10 % RH do 30 % RH CMC 1,5 % RH\n(90 – 95) °C od 30 % RH do 95 % RH CMC 1,7 % RH\nPorównanie z wzorcowym psychrometrem aspiracyjnym","reference":"Interní metoda 4 (DKD-R_5.7 metoda A a B)","norm_bases":["Interní metoda 4","DKD-R_5.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność względna","regulatory_area_en":"CMC for the field of measured quantity: Relative humidity","regulatory_area_zh":"被测量领域的CMC：相对湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Relativní vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotnościomierze jako część torów pomiarowych komór i szaf klimatycznych oraz szaf specjalnego przeznaczenia, w których można wytworzyć wilgotność i temperaturę Wzorcowanie – wilgotność względna Porównanie z wzorcowym psychrometrem aspiracyjnym (10 – 20) °C od 10 % RH do 30 % RH CMC 1,8 % RH (10 – 20) °C od 30 % RH do 95 % RH CMC 2,4 % RH (20 – 90) °C od 10 % RH do 30 % RH CMC 1,6 % RH (20 – 90) °C od 30 % RH do 95 % RH CMC 2,0 % RH (90 – 95) °C od 10 % RH do 30 % RH CMC 1,5 % RH (90 – 95) °C od 30 % RH do 95 % RH CMC 1,7 % RH Vlhkoměry jako součást měřících řetězců klimatických komor a skříní, a skříní pro speciální účely, kde lze generovat vlhkost a teplotu Kalibrace – relativní vlhkost Porovnání s etalonovým aspiračním vlhkoměrem (10 - 20) °C 10 % RH až 30 % RH CMC 1,8 % RH (10 - 20) °C 30 % RH až 95 % RH CMC 2,4 % RH (20 - 90) °C 10 % RH až 30 % RH CMC 1,6 % RH (20 - 90) °C 30 % RH až 95 % RH CMC 2,0 % RH (90 - 95) °C 10 % RH až 30 % RH CMC 1,5 % RH (90 - 95) °C 30 % RH až 95 % RH CMC 1,7 % RH Interní metoda 4 (DKD-R_5.7 metoda A a B) Wilgotnosciomierze jako czesc torow pomiarowych komor i szaf klimatycznych oraz szaf specjalnego przeznaczenia, w ktorych mozna wytworzyc wilgotnosc i temperature Wzorcowanie – wilgotnosc wzgledna Porownanie z wzorcowym psychrometrem aspiracyjnym (10 – 20) °C od 10 % RH do 30 % RH CMC 1,8 % RH (10 – 20) °C od 30 % RH do 95 % RH CMC 2,4 % RH (20 – 90) °C od 10 % RH do 30 % RH CMC 1,6 % RH (20 – 90) °C od 30 % RH do 95 % RH CMC 2,0 % RH (90 – 95) °C od 10 % RH do 30 % RH CMC 1,5 % RH (90 – 95) °C od 30 % RH do 95 % RH CMC 1,7 % RH Vlhkomery jako soucast mericich retezcu klimatickych komor a skrini, a skrini pro specialni ucely, kde lze generovat vlhkost a teplotu Kalibrace – relativni vlhkost Porovnani s etalonovym aspiracnim vlhkomerem (10 - 20) °C 10 % RH az 30 % RH CMC 1,8 % RH (10 - 20) °C 30 % RH az 95 % RH CMC 2,4 % RH (20 - 90) °C 10 % RH az 30 % RH CMC 1,6 % RH (20 - 90) °C 30 % RH az 95 % RH CMC 2,0 % RH (90 - 95) °C 10 % RH az 30 % RH CMC 1,5 % RH (90 - 95) °C 30 % RH az 95 % RH CMC 1,7 % RH Interni metoda 4 (DKD-R_5.7 metoda A a B)","search_en":"Hygrometers integrated in measuring chains of climatic chambers and enclosures and special-purpose enclosures, where humidity and temperature can be generated Calibration – relative humidity Comparison with a standard aspiration hygrometer (10 to 20) °C 10 % RH to 30 % RH CMC 1,8 % RH (10 to 20) °C 30 % RH to 95 % RH CMC 2,4 % RH (20 to 90) °C 10 % RH to 30 % RH CMC 1,6 % RH (20 to 90) °C 30 % RH to 95 % RH CMC 2,0 % RH (90 to 95) °C 10 % RH to 30 % RH CMC 1,5 % RH (90 to 95) °C 30 % RH to 95 % RH CMC 1,7 % RH Interní metoda 4 (DKD-R_5.7 metoda A a B)","search_zh":"气候箱和柜以及可产生湿度和温度的专用柜测量链中的湿度计 校准 – 相对湿度 与标准通风湿度计比较 (10 - 20) °C 10 % RH 至 30 % RH CMC 1,8 % RH (10 - 20) °C 30 % RH 至 95 % RH CMC 2,4 % RH (20 - 90) °C 10 % RH 至 30 % RH CMC 1,6 % RH (20 - 90) °C 30 % RH 至 95 % RH CMC 2,0 % RH (90 - 95) °C 10 % RH 至 30 % RH CMC 1,5 % RH (90 - 95) °C 30 % RH 至 95 % RH CMC 1,7 % RH Interní metoda 4 (DKD-R_5.7 metoda A a B)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e21eab756e6d719d5a80c2ff","lab_id":"6acfffe1ff06824761705e0b","country":"CZ","accr_number":"2298","accr_body":"ČIA","row_label":"3","test_object":"Wilgotnościomierze, tory pomiarowe wilgotności względnej, rejestratory danych do pomiaru wilgotności względnej","test_object_en":"Hygrometers, measuring chains for measuring relative humidity, data loggers for measuring relative humidity","test_object_zh":"湿度计、相对湿度测量链、相对湿度数据记录器","test_object_cs":"Vlhkoměry, měřící řetězce pro měření relativní vlhkosti, datalogery pro měření relativní vlhkosti","methodology":"Wzorcowanie – wilgotność względna","methodology_en":"Calibration – relative humidity","methodology_zh":"校准 – 相对湿度","methodology_cs":"Kalibrace – relativní vlhkost","parameters":[{"name":"(10 – 90) °C","range":"od 10 % RH do 60 % RH","cmc":"2,3 % RH"},{"name":"(10 – 90) °C","range":"od 60 % RH do 90 % RH","cmc":"3,2 % RH"},{"name":"(10 – 90) °C","range":"od 90 % RH do 95 % RH","cmc":"3,5 % RH"}],"parameters_en":[{"name":"(10 to 90) °C","range":"10 % RH to 60 % RH","cmc":"2,3 % RH"},{"name":"(10 to 90) °C","range":"60 % RH to 90 % RH","cmc":"3,2 % RH"},{"name":"(10 to 90) °C","range":"90 % RH to 95 % RH","cmc":"3,5 % RH"}],"parameters_zh":[{"name":"(10 - 90) °C","range":"10 % RH 至 60 % RH","cmc":"2,3 % RH"},{"name":"(10 - 90) °C","range":"60 % RH 至 90 % RH","cmc":"3,2 % RH"},{"name":"(10 - 90) °C","range":"90 % RH 至 95 % RH","cmc":"3,5 % RH"}],"parameters_cs":[{"name":"(10 - 90) °C","range":"10 % RH až 60 % RH","cmc":"2,3 % RH"},{"name":"(10 - 90) °C","range":"60 % RH až 90 % RH","cmc":"3,2 % RH"},{"name":"(10 - 90) °C","range":"90 % RH až 95 % RH","cmc":"3,5 % RH"}],"technique":"Porównanie z wzorcowym psychrometrem aspiracyjnym w komorze klimatycznej","technique_en":"Comparison with a standard aspiration hygrometer in a climatic chamber","technique_zh":"在气候箱中与标准通风湿度计比较","technique_cs":"Porovnání s etalonovým aspiračním vlhkoměrem v klimatické komoře","techniques":["Porównanie z wzorcowym psychrometrem aspiracyjnym w komorze klimatycznej"],"techniques_en":["Comparison with a standard aspiration hygrometer in a climatic chamber"],"techniques_zh":["在气候箱中与标准通风湿度计比较"],"techniques_cs":["Porovnání s etalonovým aspiračním vlhkoměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność względna\nZakres:\n(10 – 90) °C od 10 % RH do 60 % RH CMC 2,3 % RH\n(10 – 90) °C od 60 % RH do 90 % RH CMC 3,2 % RH\n(10 – 90) °C od 90 % RH do 95 % RH CMC 3,5 % RH\nPorównanie z wzorcowym psychrometrem aspiracyjnym w komorze klimatycznej","reference":"Interní metoda 6","norm_bases":["Interní metoda 6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność względna","regulatory_area_en":"CMC for the field of measured quantity: Relative humidity","regulatory_area_zh":"被测量领域的CMC：相对湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Relativní vlhkost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotnościomierze, tory pomiarowe wilgotności względnej, rejestratory danych do pomiaru wilgotności względnej Wzorcowanie – wilgotność względna Porównanie z wzorcowym psychrometrem aspiracyjnym w komorze klimatycznej (10 – 90) °C od 10 % RH do 60 % RH CMC 2,3 % RH (10 – 90) °C od 60 % RH do 90 % RH CMC 3,2 % RH (10 – 90) °C od 90 % RH do 95 % RH CMC 3,5 % RH Vlhkoměry, měřící řetězce pro měření relativní vlhkosti, datalogery pro měření relativní vlhkosti Kalibrace – relativní vlhkost Porovnání s etalonovým aspiračním vlhkoměrem v klimatické komoře (10 - 90) °C 10 % RH až 60 % RH CMC 2,3 % RH (10 - 90) °C 60 % RH až 90 % RH CMC 3,2 % RH (10 - 90) °C 90 % RH až 95 % RH CMC 3,5 % RH Interní metoda 6 Wilgotnosciomierze, tory pomiarowe wilgotnosci wzglednej, rejestratory danych do pomiaru wilgotnosci wzglednej Wzorcowanie – wilgotnosc wzgledna Porownanie z wzorcowym psychrometrem aspiracyjnym w komorze klimatycznej (10 – 90) °C od 10 % RH do 60 % RH CMC 2,3 % RH (10 – 90) °C od 60 % RH do 90 % RH CMC 3,2 % RH (10 – 90) °C od 90 % RH do 95 % RH CMC 3,5 % RH Vlhkomery, merici retezce pro mereni relativni vlhkosti, datalogery pro mereni relativni vlhkosti Kalibrace – relativni vlhkost Porovnani s etalonovym aspiracnim vlhkomerem v klimaticke komore (10 - 90) °C 10 % RH az 60 % RH CMC 2,3 % RH (10 - 90) °C 60 % RH az 90 % RH CMC 3,2 % RH (10 - 90) °C 90 % RH az 95 % RH CMC 3,5 % RH Interni metoda 6","search_en":"Hygrometers, measuring chains for measuring relative humidity, data loggers for measuring relative humidity Calibration – relative humidity Comparison with a standard aspiration hygrometer in a climatic chamber (10 to 90) °C 10 % RH to 60 % RH CMC 2,3 % RH (10 to 90) °C 60 % RH to 90 % RH CMC 3,2 % RH (10 to 90) °C 90 % RH to 95 % RH CMC 3,5 % RH Interní metoda 6","search_zh":"湿度计、相对湿度测量链、相对湿度数据记录器 校准 – 相对湿度 在气候箱中与标准通风湿度计比较 (10 - 90) °C 10 % RH 至 60 % RH CMC 2,3 % RH (10 - 90) °C 60 % RH 至 90 % RH CMC 3,2 % RH (10 - 90) °C 90 % RH 至 95 % RH CMC 3,5 % RH Interní metoda 6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}