{"lab":{"_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","address":"Pod lisem 129/2, Troja, 182 00 Praha 8","categories":["metrology"],"city":"Praha 8","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4339283,50.1164839]},"map_coord":[50.1164839,14.4339283],"map_geo":"cai-mapa","methods_count":95,"name":"Elektrotechnický zkušební ústav, s.p.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów do pomiaru wielkości elektrycznych, wielkości optycznych, temperatury, częstotliwości i czasu.","search_text":"elektrotechnický zkušební ústav, s.p. pod lisem 129/2, troja, 182 00 praha 8 2294","source_page_url":"https://www.cai.cz/?subjekt=2294-elektrotechnicky-zkusebni-ustav-s-p","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"12-02-2029","website":"www.ezu.cz","certificate_date":"27.03.2024","certificate_no":"90/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów do pomiaru wielkości elektrycznych, wielkości optycznych, temperatury, częstotliwości i czasu.","en":"Calibration of measuring instruments for electrical quantities, optical quantities, temperature, frequency and time.","zh":"电学量、光学量、温度、频率和时间测量仪器的校准。","cs":"Kalibrace měřidel elektrických veličin, optických veličin, teploty, frekvence a času."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"50bcf46008489cbb099ca0eae611828ec639955f0181a50f2e3237a839a317be","source_pdf_url":"https://www.cai.cz/OA/pdf/P90_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"b3051883969d2fc203657c83","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące i tory pomiarowe temperatury","test_object_en":"Indicating thermometers and temperature measuring chains","test_object_zh":"指示式温度计和温度测量链","test_object_cs":"Indikační teploměry a měřicí řetězce teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"w bloku homogenizującym","range":"od -20 °C do 0 °C","cmc":"0,10 °C"},{"name":"w łaźni wodnej","range":"od 0 °C do 90 °C","cmc":"0,050 °C"},{"name":"w bloku homogenizującym","range":"od 90 °C do 420 °C","cmc":"0,10 %"}],"parameters_en":[{"name":"in a homogenizing block","range":"-20 °C to 0 °C","cmc":"0,10 °C"},{"name":"in a water bath","range":"0 °C to 90 °C","cmc":"0,050 °C"},{"name":"in a homogenizing block","range":"90 °C to 420 °C","cmc":"0,10 %"}],"parameters_zh":[{"name":"在均温块中","range":"-20 °C 至 0 °C","cmc":"0,10 °C"},{"name":"在水浴中","range":"0 °C 至 90 °C","cmc":"0,050 °C"},{"name":"在均温块中","range":"90 °C 至 420 °C","cmc":"0,10 %"}],"parameters_cs":[{"name":"v homogenizačním bloku","range":"-20 °C až 0 °C","cmc":"0,10 °C"},{"name":"ve vodní lázni","range":"0 °C až 90 °C","cmc":"0,050 °C"},{"name":"v homogenizačním bloku","range":"90 °C až 420 °C","cmc":"0,10 %"}],"technique":"Porównanie z termometrem wzorcowym:","technique_en":"Comparison with a standard thermometer:","technique_zh":"与标准温度计比较：","technique_cs":"Porovnání s etalonovým teploměrem:","techniques":["Porównanie z termometrem wzorcowym:"],"techniques_en":["Comparison with a standard thermometer:"],"techniques_zh":["与标准温度计比较："],"techniques_cs":["Porovnání s etalonovým teploměrem:"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nw bloku homogenizującym od -20 °C do 0 °C CMC 0,10 °C\nw łaźni wodnej od 0 °C do 90 °C CMC 0,050 °C\nw bloku homogenizującym od 90 °C do 420 °C CMC 0,10 %\nPorównanie z termometrem wzorcowym:","reference":"MK20","norm_bases":["MK20"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące i tory pomiarowe temperatury Wzorcowanie – temperatura Porównanie z termometrem wzorcowym: w bloku homogenizującym od -20 °C do 0 °C CMC 0,10 °C w łaźni wodnej od 0 °C do 90 °C CMC 0,050 °C w bloku homogenizującym od 90 °C do 420 °C CMC 0,10 % Indikační teploměry a měřicí řetězce teploty Kalibrace – teplota Porovnání s etalonovým teploměrem: v homogenizačním bloku -20 °C až 0 °C CMC 0,10 °C ve vodní lázni 0 °C až 90 °C CMC 0,050 °C v homogenizačním bloku 90 °C až 420 °C CMC 0,10 % MK20 Termometry wskazujace i tory pomiarowe temperatury Wzorcowanie – temperatura Porownanie z termometrem wzorcowym: w bloku homogenizujacym od -20 °C do 0 °C CMC 0,10 °C w lazni wodnej od 0 °C do 90 °C CMC 0,050 °C w bloku homogenizujacym od 90 °C do 420 °C CMC 0,10 % Indikacni teplomery a merici retezce teploty Kalibrace – teplota Porovnani s etalonovym teplomerem: v homogenizacnim bloku -20 °C az 0 °C CMC 0,10 °C ve vodni lazni 0 °C az 90 °C CMC 0,050 °C v homogenizacnim bloku 90 °C az 420 °C CMC 0,10 % MK20","search_en":"Indicating thermometers and temperature measuring chains Calibration – temperature Comparison with a standard thermometer: in a homogenizing block -20 °C to 0 °C CMC 0,10 °C in a water bath 0 °C to 90 °C CMC 0,050 °C in a homogenizing block 90 °C to 420 °C CMC 0,10 % MK20","search_zh":"指示式温度计和温度测量链 校准 – 温度 与标准温度计比较： 在均温块中 -20 °C 至 0 °C CMC 0,10 °C 在水浴中 0 °C 至 90 °C CMC 0,050 °C 在均温块中 90 °C 至 420 °C CMC 0,10 % MK20","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ee71b2097e683a2772d71135","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"2","test_object":"Termometry komór temperaturowych","test_object_en":"Thermometers of temperature chambers","test_object_zh":"温度箱温度计","test_object_cs":"Teploměry teplotních komor","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do 0 °C","cmc":"0,50 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"0,30 °C"},{"name":"","range":"od 50 °C do 250 °C","cmc":"0,40 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 0 °C","cmc":"0,50 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"0,30 °C"},{"name":"","range":"50 °C to 250 °C","cmc":"0,40 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 0 °C","cmc":"0,50 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"0,30 °C"},{"name":"","range":"50 °C 至 250 °C","cmc":"0,40 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až 0 °C","cmc":"0,50 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"0,30 °C"},{"name":"","range":"50 °C až 250 °C","cmc":"0,40 °C"}],"technique":"Porównanie z termometrem wzorcowym w komorze temperaturowej","technique_en":"Comparison with a standard thermometer in a temperature chamber","technique_zh":"在温度箱中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v teplotní komoře","techniques":["Porównanie z termometrem wzorcowym w komorze temperaturowej"],"techniques_en":["Comparison with a standard thermometer in a temperature chamber"],"techniques_zh":["在温度箱中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v teplotní komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do 0 °C CMC 0,50 °C\nod 0 °C do 50 °C CMC 0,30 °C\nod 50 °C do 250 °C CMC 0,40 °C\nPorównanie z termometrem wzorcowym w komorze temperaturowej","reference":"MK20","norm_bases":["MK20"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry komór temperaturowych Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w komorze temperaturowej od -80 °C do 0 °C CMC 0,50 °C od 0 °C do 50 °C CMC 0,30 °C od 50 °C do 250 °C CMC 0,40 °C Teploměry teplotních komor Kalibrace – teplota Porovnání s etalonovým teploměrem v teplotní komoře -80 °C až 0 °C CMC 0,50 °C 0 °C až 50 °C CMC 0,30 °C 50 °C až 250 °C CMC 0,40 °C MK20 Termometry komor temperaturowych Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w komorze temperaturowej od -80 °C do 0 °C CMC 0,50 °C od 0 °C do 50 °C CMC 0,30 °C od 50 °C do 250 °C CMC 0,40 °C Teplomery teplotnich komor Kalibrace – teplota Porovnani s etalonovym teplomerem v teplotni komore -80 °C az 0 °C CMC 0,50 °C 0 °C az 50 °C CMC 0,30 °C 50 °C az 250 °C CMC 0,40 °C MK20","search_en":"Thermometers of temperature chambers Calibration – temperature Comparison with a standard thermometer in a temperature chamber -80 °C to 0 °C CMC 0,50 °C 0 °C to 50 °C CMC 0,30 °C 50 °C to 250 °C CMC 0,40 °C MK20","search_zh":"温度箱温度计 校准 – 温度 在温度箱中与标准温度计比较 -80 °C 至 0 °C CMC 0,50 °C 0 °C 至 50 °C CMC 0,30 °C 50 °C 至 250 °C CMC 0,40 °C MK20","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"235e266c627485c233369fff","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"3","test_object":"Symulacja termopary / termometry, kalibratory procesowe","test_object_en":"Thermocouple simulation / Thermometers, process calibrators","test_object_zh":"热电偶模拟 / 温度计、过程校准器","test_object_cs":"Simulace termoelektrického článku / Teploměry, procesní kalibrátory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Typ K","range":"od -200 °C do -100 °C","cmc":"0,33 °C"},{"name":"Typ K","range":"od -100 °C do -25 °C","cmc":"0,18 °C"},{"name":"Typ K","range":"od -25 °C do 120 °C","cmc":"0,16 °C"},{"name":"Typ K","range":"od 120 °C do 1000 °C","cmc":"0,26 °C"},{"name":"Typ K","range":"od 1000 °C do 1372 °C","cmc":"0,40 °C"},{"name":"Typ J","range":"od -210 °C do -100 °C","cmc":"0,27 °C"},{"name":"Typ J","range":"od -100 °C do -30 °C","cmc":"0,16 °C"},{"name":"Typ J","range":"od -30 °C do 150 °C","cmc":"0,14 °C"},{"name":"Typ J","range":"od 150 °C do 760 °C","cmc":"0,17 °C"},{"name":"Typ J","range":"od 760 °C do 1200 °C","cmc":"0,23 °C"},{"name":"Typ T","range":"od -250 °C do -150 °C","cmc":"0,63 °C"},{"name":"Typ T","range":"od -150 °C do 0 °C","cmc":"0,24 °C"},{"name":"Typ T","range":"od 0 °C do 120 °C","cmc":"0,16 °C"},{"name":"Typ T","range":"od 120 °C do 400 °C","cmc":"0,14 °C"},{"name":"Typ S","range":"od 0 °C do 250 °C","cmc":"0,47 °C"},{"name":"Typ S","range":"od 250 °C do 1000 °C","cmc":"0,36 °C"},{"name":"Typ S","range":"od 1000 °C do 1400 °C","cmc":"0,37 °C"},{"name":"Typ S","range":"od 1400 °C do 1767 °C","cmc":"0,46 °C"},{"name":"Typ B","range":"od 600 °C do 800 °C","cmc":"0,44 °C"},{"name":"Typ B","range":"od 800 °C do 1000 °C","cmc":"0,34 °C"},{"name":"Typ B","range":"od 1000 °C do 1550 °C","cmc":"0,30 °C"},{"name":"Typ B","range":"od 1550 °C do 1820 °C","cmc":"0,33 °C"},{"name":"Typ E","range":"od -250 °C do -100 °C","cmc":"0,50 °C"},{"name":"Typ E","range":"od -100 °C do -25 °C","cmc":"0,16 °C"},{"name":"Typ E","range":"od -25 °C do 350 °C","cmc":"0,14 °C"},{"name":"Typ E","range":"od 350 °C do 650 °C","cmc":"0,16 °C"},{"name":"Typ E","range":"od 650 °C do 1000 °C","cmc":"0,21 °C"},{"name":"Typ N","range":"od -200 °C do -100 °C","cmc":"0,40 °C"},{"name":"Typ N","range":"od -100 °C do -25 °C","cmc":"0,22 °C"},{"name":"Typ N","range":"od -25 °C do 120 °C","cmc":"0,19 °C"},{"name":"Typ N","range":"od 120 °C do 410 °C","cmc":"0,18 °C"},{"name":"Typ N","range":"od 410 °C do 1300 °C","cmc":"0,27 °C"}],"parameters_en":[{"name":"Type K","range":"-200 °C to -100 °C","cmc":"0,33 °C"},{"name":"Type K","range":"-100 °C to -25 °C","cmc":"0,18 °C"},{"name":"Type K","range":"-25 °C to 120 °C","cmc":"0,16 °C"},{"name":"Type K","range":"120 °C to 1000 °C","cmc":"0,26 °C"},{"name":"Type K","range":"1000 °C to 1372 °C","cmc":"0,40 °C"},{"name":"Type J","range":"-210 °C to -100 °C","cmc":"0,27 °C"},{"name":"Type J","range":"-100 °C to -30 °C","cmc":"0,16 °C"},{"name":"Type J","range":"-30 °C to 150 °C","cmc":"0,14 °C"},{"name":"Type J","range":"150 °C to 760 °C","cmc":"0,17 °C"},{"name":"Type J","range":"760 °C to 1200 °C","cmc":"0,23 °C"},{"name":"Type T","range":"-250 °C to -150 °C","cmc":"0,63 °C"},{"name":"Type T","range":"-150 °C to 0 °C","cmc":"0,24 °C"},{"name":"Type T","range":"0 °C to 120 °C","cmc":"0,16 °C"},{"name":"Type T","range":"120 °C to 400 °C","cmc":"0,14 °C"},{"name":"Type S","range":"0 °C to 250 °C","cmc":"0,47 °C"},{"name":"Type S","range":"250 °C to 1000 °C","cmc":"0,36 °C"},{"name":"Type S","range":"1000 °C to 1400 °C","cmc":"0,37 °C"},{"name":"Type S","range":"1400 °C to 1767 °C","cmc":"0,46 °C"},{"name":"Type B","range":"600 °C to 800 °C","cmc":"0,44 °C"},{"name":"Type B","range":"800 °C to 1000 °C","cmc":"0,34 °C"},{"name":"Type B","range":"1000 °C to 1550 °C","cmc":"0,30 °C"},{"name":"Type B","range":"1550 °C to 1820 °C","cmc":"0,33 °C"},{"name":"Type E","range":"-250 °C to -100 °C","cmc":"0,50 °C"},{"name":"Type E","range":"-100 °C to -25 °C","cmc":"0,16 °C"},{"name":"Type E","range":"-25 °C to 350 °C","cmc":"0,14 °C"},{"name":"Type E","range":"350 °C to 650 °C","cmc":"0,16 °C"},{"name":"Type E","range":"650 °C to 1000 °C","cmc":"0,21 °C"},{"name":"Type N","range":"-200 °C to -100 °C","cmc":"0,40 °C"},{"name":"Type N","range":"-100 °C to -25 °C","cmc":"0,22 °C"},{"name":"Type N","range":"-25 °C to 120 °C","cmc":"0,19 °C"},{"name":"Type N","range":"120 °C to 410 °C","cmc":"0,18 °C"},{"name":"Type N","range":"410 °C to 1300 °C","cmc":"0,27 °C"}],"parameters_zh":[{"name":"K 型","range":"-200 °C 至 -100 °C","cmc":"0,33 °C"},{"name":"K 型","range":"-100 °C 至 -25 °C","cmc":"0,18 °C"},{"name":"K 型","range":"-25 °C 至 120 °C","cmc":"0,16 °C"},{"name":"K 型","range":"120 °C 至 1000 °C","cmc":"0,26 °C"},{"name":"K 型","range":"1000 °C 至 1372 °C","cmc":"0,40 °C"},{"name":"J 型","range":"-210 °C 至 -100 °C","cmc":"0,27 °C"},{"name":"J 型","range":"-100 °C 至 -30 °C","cmc":"0,16 °C"},{"name":"J 型","range":"-30 °C 至 150 °C","cmc":"0,14 °C"},{"name":"J 型","range":"150 °C 至 760 °C","cmc":"0,17 °C"},{"name":"J 型","range":"760 °C 至 1200 °C","cmc":"0,23 °C"},{"name":"T 型","range":"-250 °C 至 -150 °C","cmc":"0,63 °C"},{"name":"T 型","range":"-150 °C 至 0 °C","cmc":"0,24 °C"},{"name":"T 型","range":"0 °C 至 120 °C","cmc":"0,16 °C"},{"name":"T 型","range":"120 °C 至 400 °C","cmc":"0,14 °C"},{"name":"S 型","range":"0 °C 至 250 °C","cmc":"0,47 °C"},{"name":"S 型","range":"250 °C 至 1000 °C","cmc":"0,36 °C"},{"name":"S 型","range":"1000 °C 至 1400 °C","cmc":"0,37 °C"},{"name":"S 型","range":"1400 °C 至 1767 °C","cmc":"0,46 °C"},{"name":"B 型","range":"600 °C 至 800 °C","cmc":"0,44 °C"},{"name":"B 型","range":"800 °C 至 1000 °C","cmc":"0,34 °C"},{"name":"B 型","range":"1000 °C 至 1550 °C","cmc":"0,30 °C"},{"name":"B 型","range":"1550 °C 至 1820 °C","cmc":"0,33 °C"},{"name":"E 型","range":"-250 °C 至 -100 °C","cmc":"0,50 °C"},{"name":"E 型","range":"-100 °C 至 -25 °C","cmc":"0,16 °C"},{"name":"E 型","range":"-25 °C 至 350 °C","cmc":"0,14 °C"},{"name":"E 型","range":"350 °C 至 650 °C","cmc":"0,16 °C"},{"name":"E 型","range":"650 °C 至 1000 °C","cmc":"0,21 °C"},{"name":"N 型","range":"-200 °C 至 -100 °C","cmc":"0,40 °C"},{"name":"N 型","range":"-100 °C 至 -25 °C","cmc":"0,22 °C"},{"name":"N 型","range":"-25 °C 至 120 °C","cmc":"0,19 °C"},{"name":"N 型","range":"120 °C 至 410 °C","cmc":"0,18 °C"},{"name":"N 型","range":"410 °C 至 1300 °C","cmc":"0,27 °C"}],"parameters_cs":[{"name":"Typ K","range":"-200 °C až -100 °C","cmc":"0,33 °C"},{"name":"Typ K","range":"-100 °C až -25 °C","cmc":"0,18 °C"},{"name":"Typ K","range":"-25 °C až 120 °C","cmc":"0,16 °C"},{"name":"Typ K","range":"120 °C až 1000 °C","cmc":"0,26 °C"},{"name":"Typ K","range":"1000 °C až 1372 °C","cmc":"0,40 °C"},{"name":"Typ J","range":"-210 °C až -100 °C","cmc":"0,27 °C"},{"name":"Typ J","range":"-100 °C až -30 °C","cmc":"0,16 °C"},{"name":"Typ J","range":"-30 °C až 150 °C","cmc":"0,14 °C"},{"name":"Typ J","range":"150 °C až 760 °C","cmc":"0,17 °C"},{"name":"Typ J","range":"760 °C až 1200 °C","cmc":"0,23 °C"},{"name":"Typ T","range":"-250 °C až -150 °C","cmc":"0,63 °C"},{"name":"Typ T","range":"-150 °C až 0 °C","cmc":"0,24 °C"},{"name":"Typ T","range":"0 °C až 120 °C","cmc":"0,16 °C"},{"name":"Typ T","range":"120 °C až 400 °C","cmc":"0,14 °C"},{"name":"Typ S","range":"0 °C až 250 °C","cmc":"0,47 °C"},{"name":"Typ S","range":"250 °C až 1000 °C","cmc":"0,36 °C"},{"name":"Typ S","range":"1000 °C až 1400 °C","cmc":"0,37 °C"},{"name":"Typ S","range":"1400 °C až 1767 °C","cmc":"0,46 °C"},{"name":"Typ B","range":"600 °C až 800 °C","cmc":"0,44 °C"},{"name":"Typ B","range":"800 °C až 1000 °C","cmc":"0,34 °C"},{"name":"Typ B","range":"1000 °C až 1550 °C","cmc":"0,30 °C"},{"name":"Typ B","range":"1550 °C až 1820 °C","cmc":"0,33 °C"},{"name":"Typ E","range":"-250 °C až -100 °C","cmc":"0,50 °C"},{"name":"Typ E","range":"-100 °C až -25 °C","cmc":"0,16 °C"},{"name":"Typ E","range":"-25 °C až 350 °C","cmc":"0,14 °C"},{"name":"Typ E","range":"350 °C až 650 °C","cmc":"0,16 °C"},{"name":"Typ E","range":"650 °C až 1000 °C","cmc":"0,21 °C"},{"name":"Typ N","range":"-200 °C až -100 °C","cmc":"0,40 °C"},{"name":"Typ N","range":"-100 °C až -25 °C","cmc":"0,22 °C"},{"name":"Typ N","range":"-25 °C až 120 °C","cmc":"0,19 °C"},{"name":"Typ N","range":"120 °C až 410 °C","cmc":"0,18 °C"},{"name":"Typ N","range":"410 °C až 1300 °C","cmc":"0,27 °C"}],"technique":"Kalibrator wzorcowy: generowanie lub pomiar z uwzględnieniem wpływu CJC","technique_en":"Standard calibrator: generation or measurement including the CJC effect","technique_zh":"标准校准器：产生或测量（含冷端补偿影响）","technique_cs":"Etalonový kalibrátor: generování nebo měření včetně vlivu CJC","techniques":["Kalibrator wzorcowy: generowanie lub pomiar z uwzględnieniem wpływu CJC"],"techniques_en":["Standard calibrator: generation or measurement including the CJC effect"],"techniques_zh":["标准校准器：产生或测量（含冷端补偿影响）"],"techniques_cs":["Etalonový kalibrátor: generování nebo měření včetně vlivu CJC"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nTyp K od -200 °C do -100 °C CMC 0,33 °C\nTyp K od -100 °C do -25 °C CMC 0,18 °C\nTyp K od -25 °C do 120 °C CMC 0,16 °C\nTyp K od 120 °C do 1000 °C CMC 0,26 °C\nTyp K od 1000 °C do 1372 °C CMC 0,40 °C\nTyp J od -210 °C do -100 °C CMC 0,27 °C\nTyp J od -100 °C do -30 °C CMC 0,16 °C\nTyp J od -30 °C do 150 °C CMC 0,14 °C\nTyp J od 150 °C do 760 °C CMC 0,17 °C\nTyp J od 760 °C do 1200 °C CMC 0,23 °C\nTyp T od -250 °C do -150 °C CMC 0,63 °C\nTyp T od -150 °C do 0 °C CMC 0,24 °C\nTyp T od 0 °C do 120 °C CMC 0,16 °C\nTyp T od 120 °C do 400 °C CMC 0,14 °C\nTyp S od 0 °C do 250 °C CMC 0,47 °C\nTyp S od 250 °C do 1000 °C CMC 0,36 °C\nTyp S od 1000 °C do 1400 °C CMC 0,37 °C\nTyp S od 1400 °C do 1767 °C CMC 0,46 °C\nTyp B od 600 °C do 800 °C CMC 0,44 °C\nTyp B od 800 °C do 1000 °C CMC 0,34 °C\nTyp B od 1000 °C do 1550 °C CMC 0,30 °C\nTyp B od 1550 °C do 1820 °C CMC 0,33 °C\nTyp E od -250 °C do -100 °C CMC 0,50 °C\nTyp E od -100 °C do -25 °C CMC 0,16 °C\nTyp E od -25 °C do 350 °C CMC 0,14 °C\nTyp E od 350 °C do 650 °C CMC 0,16 °C\nTyp E od 650 °C do 1000 °C CMC 0,21 °C\nTyp N od -200 °C do -100 °C CMC 0,40 °C\nTyp N od -100 °C do -25 °C CMC 0,22 °C\nTyp N od -25 °C do 120 °C CMC 0,19 °C\nTyp N od 120 °C do 410 °C CMC 0,18 °C\nTyp N od 410 °C do 1300 °C CMC 0,27 °C\nKalibrator wzorcowy: generowanie lub pomiar z uwzględnieniem wpływu CJC","reference":"MK8","norm_bases":["MK8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Symulacja termopary / termometry, kalibratory procesowe Wzorcowanie – temperatura Kalibrator wzorcowy: generowanie lub pomiar z uwzględnieniem wpływu CJC Typ K od -200 °C do -100 °C CMC 0,33 °C Typ K od -100 °C do -25 °C CMC 0,18 °C Typ K od -25 °C do 120 °C CMC 0,16 °C Typ K od 120 °C do 1000 °C CMC 0,26 °C Typ K od 1000 °C do 1372 °C CMC 0,40 °C Typ J od -210 °C do -100 °C CMC 0,27 °C Typ J od -100 °C do -30 °C CMC 0,16 °C Typ J od -30 °C do 150 °C CMC 0,14 °C Typ J od 150 °C do 760 °C CMC 0,17 °C Typ J od 760 °C do 1200 °C CMC 0,23 °C Typ T od -250 °C do -150 °C CMC 0,63 °C Typ T od -150 °C do 0 °C CMC 0,24 °C Typ T od 0 °C do 120 °C CMC 0,16 °C Typ T od 120 °C do 400 °C CMC 0,14 °C Typ S od 0 °C do 250 °C CMC 0,47 °C Typ S od 250 °C do 1000 °C CMC 0,36 °C Typ S od 1000 °C do 1400 °C CMC 0,37 °C Typ S od 1400 °C do 1767 °C CMC 0,46 °C Typ B od 600 °C do 800 °C CMC 0,44 °C Typ B od 800 °C do 1000 °C CMC 0,34 °C Typ B od 1000 °C do 1550 °C CMC 0,30 °C Typ B od 1550 °C do 1820 °C CMC 0,33 °C Typ E od -250 °C do -100 °C CMC 0,50 °C Typ E od -100 °C do -25 °C CMC 0,16 °C Typ E od -25 °C do 350 °C CMC 0,14 °C Typ E od 350 °C do 650 °C CMC 0,16 °C Typ E od 650 °C do 1000 °C CMC 0,21 °C Typ N od -200 °C do -100 °C CMC 0,40 °C Typ N od -100 °C do -25 °C CMC 0,22 °C Typ N od -25 °C do 120 °C CMC 0,19 °C Typ N od 120 °C do 410 °C CMC 0,18 °C Typ N od 410 °C do 1300 °C CMC 0,27 °C Simulace termoelektrického článku / Teploměry, procesní kalibrátory Kalibrace – teplota Etalonový kalibrátor: generování nebo měření včetně vlivu CJC Typ K -200 °C až -100 °C CMC 0,33 °C Typ K -100 °C až -25 °C CMC 0,18 °C Typ K -25 °C až 120 °C CMC 0,16 °C Typ K 120 °C až 1000 °C CMC 0,26 °C Typ K 1000 °C až 1372 °C CMC 0,40 °C Typ J -210 °C až -100 °C CMC 0,27 °C Typ J -100 °C až -30 °C CMC 0,16 °C Typ J -30 °C až 150 °C CMC 0,14 °C Typ J 150 °C až 760 °C CMC 0,17 °C Typ J 760 °C až 1200 °C CMC 0,23 °C Typ T -250 °C až -150 °C CMC 0,63 °C Typ T -150 °C až 0 °C CMC 0,24 °C Typ T 0 °C až 120 °C CMC 0,16 °C Typ T 120 °C až 400 °C CMC 0,14 °C Typ S 0 °C až 250 °C CMC 0,47 °C Typ S 250 °C až 1000 °C CMC 0,36 °C Typ S 1000 °C až 1400 °C CMC 0,37 °C Typ S 1400 °C až 1767 °C CMC 0,46 °C Typ B 600 °C až 800 °C CMC 0,44 °C Typ B 800 °C až 1000 °C CMC 0,34 °C Typ B 1000 °C až 1550 °C CMC 0,30 °C Typ B 1550 °C až 1820 °C CMC 0,33 °C Typ E -250 °C až -100 °C CMC 0,50 °C Typ E -100 °C až -25 °C CMC 0,16 °C Typ E -25 °C až 350 °C CMC 0,14 °C Typ E 350 °C až 650 °C CMC 0,16 °C Typ E 650 °C až 1000 °C CMC 0,21 °C Typ N -200 °C až -100 °C CMC 0,40 °C Typ N -100 °C až -25 °C CMC 0,22 °C Typ N -25 °C až 120 °C CMC 0,19 °C Typ N 120 °C až 410 °C CMC 0,18 °C Typ N 410 °C až 1300 °C CMC 0,27 °C MK8 Symulacja termopary / termometry, kalibratory procesowe Wzorcowanie – temperatura Kalibrator wzorcowy: generowanie lub pomiar z uwzglednieniem wplywu CJC Typ K od -200 °C do -100 °C CMC 0,33 °C Typ K od -100 °C do -25 °C CMC 0,18 °C Typ K od -25 °C do 120 °C CMC 0,16 °C Typ K od 120 °C do 1000 °C CMC 0,26 °C Typ K od 1000 °C do 1372 °C CMC 0,40 °C Typ J od -210 °C do -100 °C CMC 0,27 °C Typ J od -100 °C do -30 °C CMC 0,16 °C Typ J od -30 °C do 150 °C CMC 0,14 °C Typ J od 150 °C do 760 °C CMC 0,17 °C Typ J od 760 °C do 1200 °C CMC 0,23 °C Typ T od -250 °C do -150 °C CMC 0,63 °C Typ T od -150 °C do 0 °C CMC 0,24 °C Typ T od 0 °C do 120 °C CMC 0,16 °C Typ T od 120 °C do 400 °C CMC 0,14 °C Typ S od 0 °C do 250 °C CMC 0,47 °C Typ S od 250 °C do 1000 °C CMC 0,36 °C Typ S od 1000 °C do 1400 °C CMC 0,37 °C Typ S od 1400 °C do 1767 °C CMC 0,46 °C Typ B od 600 °C do 800 °C CMC 0,44 °C Typ B od 800 °C do 1000 °C CMC 0,34 °C Typ B od 1000 °C do 1550 °C CMC 0,30 °C Typ B od 1550 °C do 1820 °C CMC 0,33 °C Typ E od -250 °C do -100 °C CMC 0,50 °C Typ E od -100 °C do -25 °C CMC 0,16 °C Typ E od -25 °C do 350 °C CMC 0,14 °C Typ E od 350 °C do 650 °C CMC 0,16 °C Typ E od 650 °C do 1000 °C CMC 0,21 °C Typ N od -200 °C do -100 °C CMC 0,40 °C Typ N od -100 °C do -25 °C CMC 0,22 °C Typ N od -25 °C do 120 °C CMC 0,19 °C Typ N od 120 °C do 410 °C CMC 0,18 °C Typ N od 410 °C do 1300 °C CMC 0,27 °C Simulace termoelektrickeho clanku / Teplomery, procesni kalibratory Kalibrace – teplota Etalonovy kalibrator: generovani nebo mereni vcetne vlivu CJC Typ K -200 °C az -100 °C CMC 0,33 °C Typ K -100 °C az -25 °C CMC 0,18 °C Typ K -25 °C az 120 °C CMC 0,16 °C Typ K 120 °C az 1000 °C CMC 0,26 °C Typ K 1000 °C az 1372 °C CMC 0,40 °C Typ J -210 °C az -100 °C CMC 0,27 °C Typ J -100 °C az -30 °C CMC 0,16 °C Typ J -30 °C az 150 °C CMC 0,14 °C Typ J 150 °C az 760 °C CMC 0,17 °C Typ J 760 °C az 1200 °C CMC 0,23 °C Typ T -250 °C az -150 °C CMC 0,63 °C Typ T -150 °C az 0 °C CMC 0,24 °C Typ T 0 °C az 120 °C CMC 0,16 °C Typ T 120 °C az 400 °C CMC 0,14 °C Typ S 0 °C az 250 °C CMC 0,47 °C Typ S 250 °C az 1000 °C CMC 0,36 °C Typ S 1000 °C az 1400 °C CMC 0,37 °C Typ S 1400 °C az 1767 °C CMC 0,46 °C Typ B 600 °C az 800 °C CMC 0,44 °C Typ B 800 °C az 1000 °C CMC 0,34 °C Typ B 1000 °C az 1550 °C CMC 0,30 °C Typ B 1550 °C az 1820 °C CMC 0,33 °C Typ E -250 °C az -100 °C CMC 0,50 °C Typ E -100 °C az -25 °C CMC 0,16 °C Typ E -25 °C az 350 °C CMC 0,14 °C Typ E 350 °C az 650 °C CMC 0,16 °C Typ E 650 °C az 1000 °C CMC 0,21 °C Typ N -200 °C az -100 °C CMC 0,40 °C Typ N -100 °C az -25 °C CMC 0,22 °C Typ N -25 °C az 120 °C CMC 0,19 °C Typ N 120 °C az 410 °C CMC 0,18 °C Typ N 410 °C az 1300 °C CMC 0,27 °C MK8","search_en":"Thermocouple simulation / Thermometers, process calibrators Calibration – temperature Standard calibrator: generation or measurement including the CJC effect Type K -200 °C to -100 °C CMC 0,33 °C Type K -100 °C to -25 °C CMC 0,18 °C Type K -25 °C to 120 °C CMC 0,16 °C Type K 120 °C to 1000 °C CMC 0,26 °C Type K 1000 °C to 1372 °C CMC 0,40 °C Type J -210 °C to -100 °C CMC 0,27 °C Type J -100 °C to -30 °C CMC 0,16 °C Type J -30 °C to 150 °C CMC 0,14 °C Type J 150 °C to 760 °C CMC 0,17 °C Type J 760 °C to 1200 °C CMC 0,23 °C Type T -250 °C to -150 °C CMC 0,63 °C Type T -150 °C to 0 °C CMC 0,24 °C Type T 0 °C to 120 °C CMC 0,16 °C Type T 120 °C to 400 °C CMC 0,14 °C Type S 0 °C to 250 °C CMC 0,47 °C Type S 250 °C to 1000 °C CMC 0,36 °C Type S 1000 °C to 1400 °C CMC 0,37 °C Type S 1400 °C to 1767 °C CMC 0,46 °C Type B 600 °C to 800 °C CMC 0,44 °C Type B 800 °C to 1000 °C CMC 0,34 °C Type B 1000 °C to 1550 °C CMC 0,30 °C Type B 1550 °C to 1820 °C CMC 0,33 °C Type E -250 °C to -100 °C CMC 0,50 °C Type E -100 °C to -25 °C CMC 0,16 °C Type E -25 °C to 350 °C CMC 0,14 °C Type E 350 °C to 650 °C CMC 0,16 °C Type E 650 °C to 1000 °C CMC 0,21 °C Type N -200 °C to -100 °C CMC 0,40 °C Type N -100 °C to -25 °C CMC 0,22 °C Type N -25 °C to 120 °C CMC 0,19 °C Type N 120 °C to 410 °C CMC 0,18 °C Type N 410 °C to 1300 °C CMC 0,27 °C MK8","search_zh":"热电偶模拟 / 温度计、过程校准器 校准 – 温度 标准校准器：产生或测量（含冷端补偿影响） K 型 -200 °C 至 -100 °C CMC 0,33 °C K 型 -100 °C 至 -25 °C CMC 0,18 °C K 型 -25 °C 至 120 °C CMC 0,16 °C K 型 120 °C 至 1000 °C CMC 0,26 °C K 型 1000 °C 至 1372 °C CMC 0,40 °C J 型 -210 °C 至 -100 °C CMC 0,27 °C J 型 -100 °C 至 -30 °C CMC 0,16 °C J 型 -30 °C 至 150 °C CMC 0,14 °C J 型 150 °C 至 760 °C CMC 0,17 °C J 型 760 °C 至 1200 °C CMC 0,23 °C T 型 -250 °C 至 -150 °C CMC 0,63 °C T 型 -150 °C 至 0 °C CMC 0,24 °C T 型 0 °C 至 120 °C CMC 0,16 °C T 型 120 °C 至 400 °C CMC 0,14 °C S 型 0 °C 至 250 °C CMC 0,47 °C S 型 250 °C 至 1000 °C CMC 0,36 °C S 型 1000 °C 至 1400 °C CMC 0,37 °C S 型 1400 °C 至 1767 °C CMC 0,46 °C B 型 600 °C 至 800 °C CMC 0,44 °C B 型 800 °C 至 1000 °C CMC 0,34 °C B 型 1000 °C 至 1550 °C CMC 0,30 °C B 型 1550 °C 至 1820 °C CMC 0,33 °C E 型 -250 °C 至 -100 °C CMC 0,50 °C E 型 -100 °C 至 -25 °C CMC 0,16 °C E 型 -25 °C 至 350 °C CMC 0,14 °C E 型 350 °C 至 650 °C CMC 0,16 °C E 型 650 °C 至 1000 °C CMC 0,21 °C N 型 -200 °C 至 -100 °C CMC 0,40 °C N 型 -100 °C 至 -25 °C CMC 0,22 °C N 型 -25 °C 至 120 °C CMC 0,19 °C N 型 120 °C 至 410 °C CMC 0,18 °C N 型 410 °C 至 1300 °C CMC 0,27 °C MK8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f335882da121c9b907db7d4","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Symulacja rezystancyjnego czujnika temperatury / termometry, kalibratory procesowe","test_object_en":"Resistance temperature sensor simulation / Thermometers, process calibrators","test_object_zh":"电阻式温度传感器模拟 / 温度计、过程校准器","test_object_cs":"Simulace odporového teplotního snímače / Teploměry, procesní kalibrátory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Pt 100","range":"od -200 °C do 0 °C","cmc":"0,050 °C"},{"name":"Pt 100","range":"od 0 °C do 100 °C","cmc":"0,070 °C"},{"name":"Pt 100","range":"od 100 °C do 300 °C","cmc":"0,090 °C"},{"name":"Pt 100","range":"od 300 °C do 400 °C","cmc":"0,10 °C"},{"name":"Pt 100","range":"od 400 °C do 630 °C","cmc":"0,12 °C"},{"name":"Pt 100","range":"od 630 °C do 800 °C","cmc":"0,14 °C"}],"parameters_en":[{"name":"Pt 100","range":"-200 °C to 0 °C","cmc":"0,050 °C"},{"name":"Pt 100","range":"0 °C to 100 °C","cmc":"0,070 °C"},{"name":"Pt 100","range":"100 °C to 300 °C","cmc":"0,090 °C"},{"name":"Pt 100","range":"300 °C to 400 °C","cmc":"0,10 °C"},{"name":"Pt 100","range":"400 °C to 630 °C","cmc":"0,12 °C"},{"name":"Pt 100","range":"630 °C to 800 °C","cmc":"0,14 °C"}],"parameters_zh":[{"name":"Pt 100","range":"-200 °C 至 0 °C","cmc":"0,050 °C"},{"name":"Pt 100","range":"0 °C 至 100 °C","cmc":"0,070 °C"},{"name":"Pt 100","range":"100 °C 至 300 °C","cmc":"0,090 °C"},{"name":"Pt 100","range":"300 °C 至 400 °C","cmc":"0,10 °C"},{"name":"Pt 100","range":"400 °C 至 630 °C","cmc":"0,12 °C"},{"name":"Pt 100","range":"630 °C 至 800 °C","cmc":"0,14 °C"}],"parameters_cs":[{"name":"Pt 100","range":"-200 °C až 0 °C","cmc":"0,050 °C"},{"name":"Pt 100","range":"0 °C až 100 °C","cmc":"0,070 °C"},{"name":"Pt 100","range":"100 °C až 300 °C","cmc":"0,090 °C"},{"name":"Pt 100","range":"300 °C až 400 °C","cmc":"0,10 °C"},{"name":"Pt 100","range":"400 °C až 630 °C","cmc":"0,12 °C"},{"name":"Pt 100","range":"630 °C až 800 °C","cmc":"0,14 °C"}],"technique":"Generowanie wzorcowym kalibratorem rezystancji lub pomiar multimetrem wzorcowym","technique_en":"Generation by a standard resistance calibrator or measurement by a standard multimeter","technique_zh":"用标准电阻校准器产生或用标准万用表测量","technique_cs":"Generování etalonovým kalibrátorem odporu nebo měření etalonovým multimetrem","techniques":["Generowanie wzorcowym kalibratorem rezystancji lub pomiar multimetrem wzorcowym"],"techniques_en":["Generation by a standard resistance calibrator or measurement by a standard multimeter"],"techniques_zh":["用标准电阻校准器产生或用标准万用表测量"],"techniques_cs":["Generování etalonovým kalibrátorem odporu nebo měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nPt 100 od -200 °C do 0 °C CMC 0,050 °C\nPt 100 od 0 °C do 100 °C CMC 0,070 °C\nPt 100 od 100 °C do 300 °C CMC 0,090 °C\nPt 100 od 300 °C do 400 °C CMC 0,10 °C\nPt 100 od 400 °C do 630 °C CMC 0,12 °C\nPt 100 od 630 °C do 800 °C CMC 0,14 °C\nGenerowanie wzorcowym kalibratorem rezystancji lub pomiar multimetrem wzorcowym","reference":"MK8","norm_bases":["MK8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Symulacja rezystancyjnego czujnika temperatury / termometry, kalibratory procesowe Wzorcowanie – temperatura Generowanie wzorcowym kalibratorem rezystancji lub pomiar multimetrem wzorcowym Pt 100 od -200 °C do 0 °C CMC 0,050 °C Pt 100 od 0 °C do 100 °C CMC 0,070 °C Pt 100 od 100 °C do 300 °C CMC 0,090 °C Pt 100 od 300 °C do 400 °C CMC 0,10 °C Pt 100 od 400 °C do 630 °C CMC 0,12 °C Pt 100 od 630 °C do 800 °C CMC 0,14 °C Simulace odporového teplotního snímače / Teploměry, procesní kalibrátory Kalibrace – teplota Generování etalonovým kalibrátorem odporu nebo měření etalonovým multimetrem Pt 100 -200 °C až 0 °C CMC 0,050 °C Pt 100 0 °C až 100 °C CMC 0,070 °C Pt 100 100 °C až 300 °C CMC 0,090 °C Pt 100 300 °C až 400 °C CMC 0,10 °C Pt 100 400 °C až 630 °C CMC 0,12 °C Pt 100 630 °C až 800 °C CMC 0,14 °C MK8 Symulacja rezystancyjnego czujnika temperatury / termometry, kalibratory procesowe Wzorcowanie – temperatura Generowanie wzorcowym kalibratorem rezystancji lub pomiar multimetrem wzorcowym Pt 100 od -200 °C do 0 °C CMC 0,050 °C Pt 100 od 0 °C do 100 °C CMC 0,070 °C Pt 100 od 100 °C do 300 °C CMC 0,090 °C Pt 100 od 300 °C do 400 °C CMC 0,10 °C Pt 100 od 400 °C do 630 °C CMC 0,12 °C Pt 100 od 630 °C do 800 °C CMC 0,14 °C Simulace odporoveho teplotniho snimace / Teplomery, procesni kalibratory Kalibrace – teplota Generovani etalonovym kalibratorem odporu nebo mereni etalonovym multimetrem Pt 100 -200 °C az 0 °C CMC 0,050 °C Pt 100 0 °C az 100 °C CMC 0,070 °C Pt 100 100 °C az 300 °C CMC 0,090 °C Pt 100 300 °C az 400 °C CMC 0,10 °C Pt 100 400 °C az 630 °C CMC 0,12 °C Pt 100 630 °C az 800 °C CMC 0,14 °C MK8","search_en":"Resistance temperature sensor simulation / Thermometers, process calibrators Calibration – temperature Generation by a standard resistance calibrator or measurement by a standard multimeter Pt 100 -200 °C to 0 °C CMC 0,050 °C Pt 100 0 °C to 100 °C CMC 0,070 °C Pt 100 100 °C to 300 °C CMC 0,090 °C Pt 100 300 °C to 400 °C CMC 0,10 °C Pt 100 400 °C to 630 °C CMC 0,12 °C Pt 100 630 °C to 800 °C CMC 0,14 °C MK8","search_zh":"电阻式温度传感器模拟 / 温度计、过程校准器 校准 – 温度 用标准电阻校准器产生或用标准万用表测量 Pt 100 -200 °C 至 0 °C CMC 0,050 °C Pt 100 0 °C 至 100 °C CMC 0,070 °C Pt 100 100 °C 至 300 °C CMC 0,090 °C Pt 100 300 °C 至 400 °C CMC 0,10 °C Pt 100 400 °C 至 630 °C CMC 0,12 °C Pt 100 630 °C 至 800 °C CMC 0,14 °C MK8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"938e285672c5e9dc5f77c02b","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / multimetry, woltomierze, testery, przetworniki, źródła i kalibratory napięcia","test_object_en":"DC voltage / Multimeters, voltmeters, testers, transducers, voltage sources and calibrators","test_object_zh":"直流电压 / 万用表、电压表、测试仪、变送器、电压源和校准器","test_object_cs":"Stejnosměrné napětí / Multimetry, voltmetry, testery, převodníky, zdroje a kalibrátory napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 200 mV","cmc":"0,00086 % + 0,3 µV"},{"name":"","range":"od 0,2 V do 0,5 V","cmc":"0,00095 %"},{"name":"","range":"od 0,5 V do 20 V","cmc":"0,00075 %"},{"name":"","range":"od 20 V do 1100 V","cmc":"0,0012 %"}],"parameters_en":[{"name":"","range":"0 mV to 200 mV","cmc":"0,00086 % + 0,3 µV"},{"name":"","range":"0,2 V to 0,5 V","cmc":"0,00095 %"},{"name":"","range":"0,5 V to 20 V","cmc":"0,00075 %"},{"name":"","range":"20 V to 1100 V","cmc":"0,0012 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 200 mV","cmc":"0,00086 % + 0,3 µV"},{"name":"","range":"0,2 V 至 0,5 V","cmc":"0,00095 %"},{"name":"","range":"0,5 V 至 20 V","cmc":"0,00075 %"},{"name":"","range":"20 V 至 1100 V","cmc":"0,0012 %"}],"parameters_cs":[{"name":"","range":"0 mV až 200 mV","cmc":"0,00086 % + 0,3 µV"},{"name":"","range":"0,2 V až 0,5 V","cmc":"0,00095 %"},{"name":"","range":"0,5 V až 20 V","cmc":"0,00075 %"},{"name":"","range":"20 V až 1100 V","cmc":"0,0012 %"}],"technique":"Multimetr wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter: comparison or direct measurement","technique_zh":"标准万用表：比较或直接测量","technique_cs":"Etalonový multimetr: porovnání nebo přímé měření","techniques":["Multimetr wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter: comparison or direct measurement"],"techniques_zh":["标准万用表：比较或直接测量"],"techniques_cs":["Etalonový multimetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 200 mV CMC 0,00086 % + 0,3 µV\nod 0,2 V do 0,5 V CMC 0,00095 %\nod 0,5 V do 20 V CMC 0,00075 %\nod 20 V do 1100 V CMC 0,0012 %\nMultimetr wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK4, MK8, MK9","norm_bases":["MK4","MK8","MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / multimetry, woltomierze, testery, przetworniki, źródła i kalibratory napięcia Wzorcowanie – wielkości elektryczne Multimetr wzorcowy: porównanie lub pomiar bezpośredni od 0 mV do 200 mV CMC 0,00086 % + 0,3 µV od 0,2 V do 0,5 V CMC 0,00095 % od 0,5 V do 20 V CMC 0,00075 % od 20 V do 1100 V CMC 0,0012 % Stejnosměrné napětí / Multimetry, voltmetry, testery, převodníky, zdroje a kalibrátory napětí Kalibrace – elektrické veličiny Etalonový multimetr: porovnání nebo přímé měření 0 mV až 200 mV CMC 0,00086 % + 0,3 µV 0,2 V až 0,5 V CMC 0,00095 % 0,5 V až 20 V CMC 0,00075 % 20 V až 1100 V CMC 0,0012 % MK4, MK8, MK9 Napiecie stale / multimetry, woltomierze, testery, przetworniki, zrodla i kalibratory napiecia Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy: porownanie lub pomiar bezposredni od 0 mV do 200 mV CMC 0,00086 % + 0,3 µV od 0,2 V do 0,5 V CMC 0,00095 % od 0,5 V do 20 V CMC 0,00075 % od 20 V do 1100 V CMC 0,0012 % Stejnosmerne napeti / Multimetry, voltmetry, testery, prevodniky, zdroje a kalibratory napeti Kalibrace – elektricke veliciny Etalonovy multimetr: porovnani nebo prime mereni 0 mV az 200 mV CMC 0,00086 % + 0,3 µV 0,2 V az 0,5 V CMC 0,00095 % 0,5 V az 20 V CMC 0,00075 % 20 V az 1100 V CMC 0,0012 % MK4, MK8, MK9","search_en":"DC voltage / Multimeters, voltmeters, testers, transducers, voltage sources and calibrators Calibration – electrical quantities Standard multimeter: comparison or direct measurement 0 mV to 200 mV CMC 0,00086 % + 0,3 µV 0,2 V to 0,5 V CMC 0,00095 % 0,5 V to 20 V CMC 0,00075 % 20 V to 1100 V CMC 0,0012 % MK4, MK8, MK9","search_zh":"直流电压 / 万用表、电压表、测试仪、变送器、电压源和校准器 校准 – 电学量 标准万用表：比较或直接测量 0 mV 至 200 mV CMC 0,00086 % + 0,3 µV 0,2 V 至 0,5 V CMC 0,00095 % 0,5 V 至 20 V CMC 0,00075 % 20 V 至 1100 V CMC 0,0012 % MK4, MK8, MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd85202f92089273df15d25c","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / woltomierze wysokonapięciowe, sondy, źródła, generatory ESD i testery","test_object_en":"DC voltage / High-voltage voltmeters, probes, sources, ESD generators and testers","test_object_zh":"直流电压 / 高压电压表、探头、电源、ESD 发生器和测试仪","test_object_cs":"Stejnosměrné napětí / Vysokonapěťové voltmetry, sondy, zdroje ESD generátory a testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1,1 kV do 10 kV","cmc":"0,50 %"},{"name":"","range":"od 10 kV do 20 kV","cmc":"0,20 %"},{"name":"","range":"od 20 kV do 40 kV","cmc":"0,50 %"},{"name":"","range":"od 40 kV do 100 kV","cmc":"0,80 %"}],"parameters_en":[{"name":"","range":"1,1 kV to 10 kV","cmc":"0,50 %"},{"name":"","range":"10 kV to 20 kV","cmc":"0,20 %"},{"name":"","range":"20 kV to 40 kV","cmc":"0,50 %"},{"name":"","range":"40 kV to 100 kV","cmc":"0,80 %"}],"parameters_zh":[{"name":"","range":"1,1 kV 至 10 kV","cmc":"0,50 %"},{"name":"","range":"10 kV 至 20 kV","cmc":"0,20 %"},{"name":"","range":"20 kV 至 40 kV","cmc":"0,50 %"},{"name":"","range":"40 kV 至 100 kV","cmc":"0,80 %"}],"parameters_cs":[{"name":"","range":"1,1 kV až 10 kV","cmc":"0,50 %"},{"name":"","range":"10 kV až 20 kV","cmc":"0,20 %"},{"name":"","range":"20 kV až 40 kV","cmc":"0,50 %"},{"name":"","range":"40 kV až 100 kV","cmc":"0,80 %"}],"technique":"Woltomierz wzorcowy wysokiego napięcia: porównanie lub pomiar bezpośredni","technique_en":"Standard high-voltage voltmeter: comparison or direct measurement","technique_zh":"标准高压电压表：比较或直接测量","technique_cs":"Etalonový vysokonapěťový voltmetr: porovnání nebo přímé měření","techniques":["Woltomierz wzorcowy wysokiego napięcia: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard high-voltage voltmeter: comparison or direct measurement"],"techniques_zh":["标准高压电压表：比较或直接测量"],"techniques_cs":["Etalonový vysokonapěťový voltmetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1,1 kV do 10 kV CMC 0,50 %\nod 10 kV do 20 kV CMC 0,20 %\nod 20 kV do 40 kV CMC 0,50 %\nod 40 kV do 100 kV CMC 0,80 %\nWoltomierz wzorcowy wysokiego napięcia: porównanie lub pomiar bezpośredni","reference":"MK10","norm_bases":["MK10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / woltomierze wysokonapięciowe, sondy, źródła, generatory ESD i testery Wzorcowanie – wielkości elektryczne Woltomierz wzorcowy wysokiego napięcia: porównanie lub pomiar bezpośredni od 1,1 kV do 10 kV CMC 0,50 % od 10 kV do 20 kV CMC 0,20 % od 20 kV do 40 kV CMC 0,50 % od 40 kV do 100 kV CMC 0,80 % Stejnosměrné napětí / Vysokonapěťové voltmetry, sondy, zdroje ESD generátory a testery Kalibrace – elektrické veličiny Etalonový vysokonapěťový voltmetr: porovnání nebo přímé měření 1,1 kV až 10 kV CMC 0,50 % 10 kV až 20 kV CMC 0,20 % 20 kV až 40 kV CMC 0,50 % 40 kV až 100 kV CMC 0,80 % MK10 Napiecie stale / woltomierze wysokonapieciowe, sondy, zrodla, generatory ESD i testery Wzorcowanie – wielkosci elektryczne Woltomierz wzorcowy wysokiego napiecia: porownanie lub pomiar bezposredni od 1,1 kV do 10 kV CMC 0,50 % od 10 kV do 20 kV CMC 0,20 % od 20 kV do 40 kV CMC 0,50 % od 40 kV do 100 kV CMC 0,80 % Stejnosmerne napeti / Vysokonapetove voltmetry, sondy, zdroje ESD generatory a testery Kalibrace – elektricke veliciny Etalonovy vysokonapetovy voltmetr: porovnani nebo prime mereni 1,1 kV az 10 kV CMC 0,50 % 10 kV az 20 kV CMC 0,20 % 20 kV az 40 kV CMC 0,50 % 40 kV az 100 kV CMC 0,80 % MK10","search_en":"DC voltage / High-voltage voltmeters, probes, sources, ESD generators and testers Calibration – electrical quantities Standard high-voltage voltmeter: comparison or direct measurement 1,1 kV to 10 kV CMC 0,50 % 10 kV to 20 kV CMC 0,20 % 20 kV to 40 kV CMC 0,50 % 40 kV to 100 kV CMC 0,80 % MK10","search_zh":"直流电压 / 高压电压表、探头、电源、ESD 发生器和测试仪 校准 – 电学量 标准高压电压表：比较或直接测量 1,1 kV 至 10 kV CMC 0,50 % 10 kV 至 20 kV CMC 0,20 % 20 kV 至 40 kV CMC 0,50 % 40 kV 至 100 kV CMC 0,80 % MK10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec3cff43c723fe6bf5dc4d73","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / multimetry, woltomierze, testery, przetworniki, źródła i kalibratory napięcia","test_object_en":"AC voltage / Multimeters, voltmeters, testers, transducers, voltage sources and calibrators","test_object_zh":"交流电压 / 万用表、电压表、测试仪、变送器、电压源和校准器","test_object_cs":"Střídavé napětí / Multimetry, voltmetry, testery, převodníky, zdroje a kalibrátory napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 0,1 mV do 33 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz do 10 kHz","range":"od 0,1 mV do 33 mV","cmc":"0,023 % + 4 µV"},{"name":"10 kHz do 20 kHz","range":"od 0,1 mV do 33 mV","cmc":"0,020 % + 6 µV"},{"name":"20 kHz do 30 kHz","range":"od 0,1 mV do 33 mV","cmc":"0,043 % + 8 µV"},{"name":"30 kHz do 50 kHz","range":"od 0,1 mV do 33 mV","cmc":"0,10 % + 6 µV"},{"name":"50 kHz do 100 kHz","range":"od 0,1 mV do 33 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz do 300 kHz","range":"od 0,1 mV do 33 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz do 500 kHz","range":"od 0,1 mV do 33 mV","cmc":"0,80 % + 50 µV"},{"name":"500 kHz do 1 MHz","range":"od 0,1 mV do 33 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz do 40 Hz","range":"od 33 mV do 200 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz do 10 kHz","range":"od 33 mV do 200 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz do 20 kHz","range":"od 33 mV do 200 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz do 50 kHz","range":"od 33 mV do 200 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz do 100 kHz","range":"od 33 mV do 200 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz do 300 kHz","range":"od 33 mV do 200 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz do 500 kHz","range":"od 33 mV do 200 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz do 1 MHz","range":"od 33 mV do 200 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz do 40 Hz","range":"od 200 mV do 330 mV","cmc":"0,019 % + 20 µV"},{"name":"40 Hz do 10 kHz","range":"od 200 mV do 330 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz do 20 kHz","range":"od 200 mV do 330 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz do 30 kHz","range":"od 200 mV do 330 mV","cmc":"0,025 % + 40 µV"},{"name":"30 kHz do 50 kHz","range":"od 200 mV do 330 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz do 100 kHz","range":"od 200 mV do 330 mV","cmc":"0,030 % + 80 µV"},{"name":"100 kHz do 500 kHz","range":"od 200 mV do 330 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz do 1 MHz","range":"od 200 mV do 330 mV","cmc":"0,60 % + 2 mV"},{"name":"10 Hz do 40 Hz","range":"od 330 mV do 2 V","cmc":"0,019 % + 20 µV"},{"name":"40 Hz do 10 kHz","range":"od 330 mV do 2 V","cmc":"0,014 % + 20 µV"},{"name":"10 kHz do 20 kHz","range":"od 330 mV do 2 V","cmc":"0,019 % + 60 µV"},{"name":"20 kHz do 30 kHz","range":"od 330 mV do 2 V","cmc":"0,018 % + 80 µV"},{"name":"30 kHz do 50 kHz","range":"od 330 mV do 2 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz do 100 kHz","range":"od 330 mV do 2 V","cmc":"0,030 % + 80 µV"},{"name":"100 kHz do 300 kHz","range":"od 330 mV do 2 V","cmc":"0,10 % + 0,4 mV"},{"name":"300 kHz do 500 kHz","range":"od 330 mV do 2 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz do 1 MHz","range":"od 330 mV do 2 V","cmc":"0,60 % + 2 mV"},{"name":"10 Hz do 40 Hz","range":"od 2 V do 3,3 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz do 10 kHz","range":"od 2 V do 3,3 V","cmc":"0,015 % + 60 µV"},{"name":"10 kHz do 30 kHz","range":"od 2 V do 3,3 V","cmc":"0,019 % + 60 µV"},{"name":"30 kHz do 50 kHz","range":"od 2 V do 3,3 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz do 100 kHz","range":"od 2 V do 3,3 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz do 300 kHz","range":"od 2 V do 3,3 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz do 500 kHz","range":"od 2 V do 3,3 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz do 1 MHz","range":"od 2 V do 3,3 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz do 40 Hz","range":"od 3,3 V do 20 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz do 10 kHz","range":"od 3,3 V do 20 V","cmc":"0,014 % + 0,2 mV"},{"name":"10 kHz do 30 kHz","range":"od 3,3 V do 20 V","cmc":"0,018 % + 0,8 mV"},{"name":"30 kHz do 100 kHz","range":"od 3,3 V do 20 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz do 300 kHz","range":"od 3,3 V do 20 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz do 1 MHz","range":"od 3,3 V do 20 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz do 40 Hz","range":"od 20 V do 33 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz do 10 kHz","range":"od 20 V do 33 V","cmc":"0,015 % + 0,6 mV"},{"name":"10 kHz do 20 kHz","range":"od 20 V do 33 V","cmc":"0,024 % + 0,6 mV"},{"name":"20 kHz do 30 kHz","range":"od 20 V do 33 V","cmc":"0,025 % + 4 mV"},{"name":"30 kHz do 50 kHz","range":"od 20 V do 33 V","cmc":"0,035 % + 0,6 mV"},{"name":"50 kHz do 100 kHz","range":"od 20 V do 33 V","cmc":"0,032 % + 8 mV"},{"name":"10 Hz do 40 Hz","range":"od 33 V do 200 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz do 10 kHz","range":"od 33 V do 200 V","cmc":"0,014 % + 2 mV"},{"name":"10 kHz do 30 kHz","range":"od 33 V do 200 V","cmc":"0,019 % + 8 mV"},{"name":"30 kHz do 50 kHz","range":"od 33 V do 200 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz do 100 kHz","range":"od 33 V do 200 V","cmc":"0,032 % + 8 mV"},{"name":"45 Hz do 10 kHz","range":"od 200 V do 330 V","cmc":"0,017 % + 10 mV"},{"name":"10 kHz do 20 kHz","range":"od 200 V do 330 V","cmc":"0,025 % + 6 mV"},{"name":"20 kHz do 50 kHz","range":"od 200 V do 330 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz do 100 kHz","range":"od 200 V do 330 V","cmc":"0,20 % + 50 mV"},{"name":"45 Hz do 10 kHz","range":"od 330 V do 500 V","cmc":"0,026 % + 10 mV"},{"name":"10 kHz do 30 kHz","range":"od 330 V do 500 V","cmc":"0,037 % + 20 mV"},{"name":"45 Hz do 1 kHz","range":"od 500 V do 1100 V","cmc":"0,030 % + 10 mV"},{"name":"1 kHz do 5 kHz","range":"od 500 V do 1100 V","cmc":"0,025 % + 10 mV"},{"name":"5 kHz do 10 kHz","range":"od 500 V do 1100 V","cmc":"0,030 % + 10 mV"},{"name":"10 kHz do 30 kHz","range":"od 500 V do 1100 V","cmc":"0,037 % + 50 mV"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"0,1 mV to 33 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz to 10 kHz","range":"0,1 mV to 33 mV","cmc":"0,023 % + 4 µV"},{"name":"10 kHz to 20 kHz","range":"0,1 mV to 33 mV","cmc":"0,020 % + 6 µV"},{"name":"20 kHz to 30 kHz","range":"0,1 mV to 33 mV","cmc":"0,043 % + 8 µV"},{"name":"30 kHz to 50 kHz","range":"0,1 mV to 33 mV","cmc":"0,10 % + 6 µV"},{"name":"50 kHz to 100 kHz","range":"0,1 mV to 33 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz to 300 kHz","range":"0,1 mV to 33 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz to 500 kHz","range":"0,1 mV to 33 mV","cmc":"0,80 % + 50 µV"},{"name":"500 kHz to 1 MHz","range":"0,1 mV to 33 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz to 40 Hz","range":"33 mV to 200 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz to 10 kHz","range":"33 mV to 200 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz to 20 kHz","range":"33 mV to 200 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz to 50 kHz","range":"33 mV to 200 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz to 100 kHz","range":"33 mV to 200 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz to 300 kHz","range":"33 mV to 200 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz to 500 kHz","range":"33 mV to 200 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz to 1 MHz","range":"33 mV to 200 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz to 40 Hz","range":"200 mV to 330 mV","cmc":"0,019 % + 20 µV"},{"name":"40 Hz to 10 kHz","range":"200 mV to 330 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz to 20 kHz","range":"200 mV to 330 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz to 30 kHz","range":"200 mV to 330 mV","cmc":"0,025 % + 40 µV"},{"name":"30 kHz to 50 kHz","range":"200 mV to 330 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz to 100 kHz","range":"200 mV to 330 mV","cmc":"0,030 % + 80 µV"},{"name":"100 kHz to 500 kHz","range":"200 mV to 330 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz to 1 MHz","range":"200 mV to 330 mV","cmc":"0,60 % + 2 mV"},{"name":"10 Hz to 40 Hz","range":"330 mV to 2 V","cmc":"0,019 % + 20 µV"},{"name":"40 Hz to 10 kHz","range":"330 mV to 2 V","cmc":"0,014 % + 20 µV"},{"name":"10 kHz to 20 kHz","range":"330 mV to 2 V","cmc":"0,019 % + 60 µV"},{"name":"20 kHz to 30 kHz","range":"330 mV to 2 V","cmc":"0,018 % + 80 µV"},{"name":"30 kHz to 50 kHz","range":"330 mV to 2 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz to 100 kHz","range":"330 mV to 2 V","cmc":"0,030 % + 80 µV"},{"name":"100 kHz to 300 kHz","range":"330 mV to 2 V","cmc":"0,10 % + 0,4 mV"},{"name":"300 kHz to 500 kHz","range":"330 mV to 2 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz to 1 MHz","range":"330 mV to 2 V","cmc":"0,60 % + 2 mV"},{"name":"10 Hz to 40 Hz","range":"2 V to 3,3 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz to 10 kHz","range":"2 V to 3,3 V","cmc":"0,015 % + 60 µV"},{"name":"10 kHz to 30 kHz","range":"2 V to 3,3 V","cmc":"0,019 % + 60 µV"},{"name":"30 kHz to 50 kHz","range":"2 V to 3,3 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz to 100 kHz","range":"2 V to 3,3 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz to 300 kHz","range":"2 V to 3,3 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz to 500 kHz","range":"2 V to 3,3 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz to 1 MHz","range":"2 V to 3,3 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz to 40 Hz","range":"3,3 V to 20 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz to 10 kHz","range":"3,3 V to 20 V","cmc":"0,014 % + 0,2 mV"},{"name":"10 kHz to 30 kHz","range":"3,3 V to 20 V","cmc":"0,018 % + 0,8 mV"},{"name":"30 kHz to 100 kHz","range":"3,3 V to 20 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz to 300 kHz","range":"3,3 V to 20 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz to 1 MHz","range":"3,3 V to 20 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz to 40 Hz","range":"20 V to 33 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz to 10 kHz","range":"20 V to 33 V","cmc":"0,015 % + 0,6 mV"},{"name":"10 kHz to 20 kHz","range":"20 V to 33 V","cmc":"0,024 % + 0,6 mV"},{"name":"20 kHz to 30 kHz","range":"20 V to 33 V","cmc":"0,025 % + 4 mV"},{"name":"30 kHz to 50 kHz","range":"20 V to 33 V","cmc":"0,035 % + 0,6 mV"},{"name":"50 kHz to 100 kHz","range":"20 V to 33 V","cmc":"0,032 % + 8 mV"},{"name":"10 Hz to 40 Hz","range":"33 V to 200 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz to 10 kHz","range":"33 V to 200 V","cmc":"0,014 % + 2 mV"},{"name":"10 kHz to 30 kHz","range":"33 V to 200 V","cmc":"0,019 % + 8 mV"},{"name":"30 kHz to 50 kHz","range":"33 V to 200 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz to 100 kHz","range":"33 V to 200 V","cmc":"0,032 % + 8 mV"},{"name":"45 Hz to 10 kHz","range":"200 V to 330 V","cmc":"0,017 % + 10 mV"},{"name":"10 kHz to 20 kHz","range":"200 V to 330 V","cmc":"0,025 % + 6 mV"},{"name":"20 kHz to 50 kHz","range":"200 V to 330 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz to 100 kHz","range":"200 V to 330 V","cmc":"0,20 % + 50 mV"},{"name":"45 Hz to 10 kHz","range":"330 V to 500 V","cmc":"0,026 % + 10 mV"},{"name":"10 kHz to 30 kHz","range":"330 V to 500 V","cmc":"0,037 % + 20 mV"},{"name":"45 Hz to 1 kHz","range":"500 V to 1100 V","cmc":"0,030 % + 10 mV"},{"name":"1 kHz to 5 kHz","range":"500 V to 1100 V","cmc":"0,025 % + 10 mV"},{"name":"5 kHz to 10 kHz","range":"500 V to 1100 V","cmc":"0,030 % + 10 mV"},{"name":"10 kHz to 30 kHz","range":"500 V to 1100 V","cmc":"0,037 % + 50 mV"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"0,1 mV 至 33 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz 至 10 kHz","range":"0,1 mV 至 33 mV","cmc":"0,023 % + 4 µV"},{"name":"10 kHz 至 20 kHz","range":"0,1 mV 至 33 mV","cmc":"0,020 % + 6 µV"},{"name":"20 kHz 至 30 kHz","range":"0,1 mV 至 33 mV","cmc":"0,043 % + 8 µV"},{"name":"30 kHz 至 50 kHz","range":"0,1 mV 至 33 mV","cmc":"0,10 % + 6 µV"},{"name":"50 kHz 至 100 kHz","range":"0,1 mV 至 33 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz 至 300 kHz","range":"0,1 mV 至 33 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz 至 500 kHz","range":"0,1 mV 至 33 mV","cmc":"0,80 % + 50 µV"},{"name":"500 kHz 至 1 MHz","range":"0,1 mV 至 33 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz 至 40 Hz","range":"33 mV 至 200 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz 至 10 kHz","range":"33 mV 至 200 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz 至 20 kHz","range":"33 mV 至 200 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz 至 50 kHz","range":"33 mV 至 200 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz 至 100 kHz","range":"33 mV 至 200 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz 至 300 kHz","range":"33 mV 至 200 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz 至 500 kHz","range":"33 mV 至 200 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz 至 1 MHz","range":"33 mV 至 200 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz 至 40 Hz","range":"200 mV 至 330 mV","cmc":"0,019 % + 20 µV"},{"name":"40 Hz 至 10 kHz","range":"200 mV 至 330 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz 至 20 kHz","range":"200 mV 至 330 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz 至 30 kHz","range":"200 mV 至 330 mV","cmc":"0,025 % + 40 µV"},{"name":"30 kHz 至 50 kHz","range":"200 mV 至 330 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz 至 100 kHz","range":"200 mV 至 330 mV","cmc":"0,030 % + 80 µV"},{"name":"100 kHz 至 500 kHz","range":"200 mV 至 330 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz 至 1 MHz","range":"200 mV 至 330 mV","cmc":"0,60 % + 2 mV"},{"name":"10 Hz 至 40 Hz","range":"330 mV 至 2 V","cmc":"0,019 % + 20 µV"},{"name":"40 Hz 至 10 kHz","range":"330 mV 至 2 V","cmc":"0,014 % + 20 µV"},{"name":"10 kHz 至 20 kHz","range":"330 mV 至 2 V","cmc":"0,019 % + 60 µV"},{"name":"20 kHz 至 30 kHz","range":"330 mV 至 2 V","cmc":"0,018 % + 80 µV"},{"name":"30 kHz 至 50 kHz","range":"330 mV 至 2 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz 至 100 kHz","range":"330 mV 至 2 V","cmc":"0,030 % + 80 µV"},{"name":"100 kHz 至 300 kHz","range":"330 mV 至 2 V","cmc":"0,10 % + 0,4 mV"},{"name":"300 kHz 至 500 kHz","range":"330 mV 至 2 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz 至 1 MHz","range":"330 mV 至 2 V","cmc":"0,60 % + 2 mV"},{"name":"10 Hz 至 40 Hz","range":"2 V 至 3,3 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz 至 10 kHz","range":"2 V 至 3,3 V","cmc":"0,015 % + 60 µV"},{"name":"10 kHz 至 30 kHz","range":"2 V 至 3,3 V","cmc":"0,019 % + 60 µV"},{"name":"30 kHz 至 50 kHz","range":"2 V 至 3,3 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz 至 100 kHz","range":"2 V 至 3,3 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz 至 300 kHz","range":"2 V 至 3,3 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz 至 500 kHz","range":"2 V 至 3,3 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz 至 1 MHz","range":"2 V 至 3,3 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz 至 40 Hz","range":"3,3 V 至 20 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz 至 10 kHz","range":"3,3 V 至 20 V","cmc":"0,014 % + 0,2 mV"},{"name":"10 kHz 至 30 kHz","range":"3,3 V 至 20 V","cmc":"0,018 % + 0,8 mV"},{"name":"30 kHz 至 100 kHz","range":"3,3 V 至 20 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz 至 300 kHz","range":"3,3 V 至 20 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz 至 1 MHz","range":"3,3 V 至 20 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz 至 40 Hz","range":"20 V 至 33 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz 至 10 kHz","range":"20 V 至 33 V","cmc":"0,015 % + 0,6 mV"},{"name":"10 kHz 至 20 kHz","range":"20 V 至 33 V","cmc":"0,024 % + 0,6 mV"},{"name":"20 kHz 至 30 kHz","range":"20 V 至 33 V","cmc":"0,025 % + 4 mV"},{"name":"30 kHz 至 50 kHz","range":"20 V 至 33 V","cmc":"0,035 % + 0,6 mV"},{"name":"50 kHz 至 100 kHz","range":"20 V 至 33 V","cmc":"0,032 % + 8 mV"},{"name":"10 Hz 至 40 Hz","range":"33 V 至 200 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz 至 10 kHz","range":"33 V 至 200 V","cmc":"0,014 % + 2 mV"},{"name":"10 kHz 至 30 kHz","range":"33 V 至 200 V","cmc":"0,019 % + 8 mV"},{"name":"30 kHz 至 50 kHz","range":"33 V 至 200 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz 至 100 kHz","range":"33 V 至 200 V","cmc":"0,032 % + 8 mV"},{"name":"45 Hz 至 10 kHz","range":"200 V 至 330 V","cmc":"0,017 % + 10 mV"},{"name":"10 kHz 至 20 kHz","range":"200 V 至 330 V","cmc":"0,025 % + 6 mV"},{"name":"20 kHz 至 50 kHz","range":"200 V 至 330 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz 至 100 kHz","range":"200 V 至 330 V","cmc":"0,20 % + 50 mV"},{"name":"45 Hz 至 10 kHz","range":"330 V 至 500 V","cmc":"0,026 % + 10 mV"},{"name":"10 kHz 至 30 kHz","range":"330 V 至 500 V","cmc":"0,037 % + 20 mV"},{"name":"45 Hz 至 1 kHz","range":"500 V 至 1100 V","cmc":"0,030 % + 10 mV"},{"name":"1 kHz 至 5 kHz","range":"500 V 至 1100 V","cmc":"0,025 % + 10 mV"},{"name":"5 kHz 至 10 kHz","range":"500 V 至 1100 V","cmc":"0,030 % + 10 mV"},{"name":"10 kHz 至 30 kHz","range":"500 V 至 1100 V","cmc":"0,037 % + 50 mV"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"0,1 mV až 33 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz až 10 kHz","range":"0,1 mV až 33 mV","cmc":"0,023 % + 4 µV"},{"name":"10 kHz až 20 kHz","range":"0,1 mV až 33 mV","cmc":"0,020 % + 6 µV"},{"name":"20 kHz až 30 kHz","range":"0,1 mV až 33 mV","cmc":"0,043 % + 8 µV"},{"name":"30 kHz až 50 kHz","range":"0,1 mV až 33 mV","cmc":"0,10 % + 6 µV"},{"name":"50 kHz až 100 kHz","range":"0,1 mV až 33 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz až 300 kHz","range":"0,1 mV až 33 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz až 500 kHz","range":"0,1 mV až 33 mV","cmc":"0,80 % + 50 µV"},{"name":"500 kHz až 1 MHz","range":"0,1 mV až 33 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz až 40 Hz","range":"33 mV až 200 mV","cmc":"0,027 % + 4 µV"},{"name":"40 Hz až 10 kHz","range":"33 mV až 200 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz až 20 kHz","range":"33 mV až 200 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz až 50 kHz","range":"33 mV až 200 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz až 100 kHz","range":"33 mV až 200 mV","cmc":"0,081 % + 20 µV"},{"name":"100 kHz až 300 kHz","range":"33 mV až 200 mV","cmc":"0,21 % + 60 µV"},{"name":"300 kHz až 500 kHz","range":"33 mV až 200 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz až 1 MHz","range":"33 mV až 200 mV","cmc":"0,61 % + 0,4 mV"},{"name":"10 Hz až 40 Hz","range":"200 mV až 330 mV","cmc":"0,019 % + 20 µV"},{"name":"40 Hz až 10 kHz","range":"200 mV až 330 mV","cmc":"0,015 % + 8 µV"},{"name":"10 kHz až 20 kHz","range":"200 mV až 330 mV","cmc":"0,016 % + 8 µV"},{"name":"20 kHz až 30 kHz","range":"200 mV až 330 mV","cmc":"0,025 % + 40 µV"},{"name":"30 kHz až 50 kHz","range":"200 mV až 330 mV","cmc":"0,035 % + 8 µV"},{"name":"50 kHz až 100 kHz","range":"200 mV až 330 mV","cmc":"0,030 % + 80 µV"},{"name":"100 kHz až 500 kHz","range":"200 mV až 330 mV","cmc":"0,20 % + 70 µV"},{"name":"500 kHz až 1 MHz","range":"200 mV až 330 mV","cmc":"0,60 % + 2 mV"},{"name":"10 Hz až 40 Hz","range":"330 mV až 2 V","cmc":"0,019 % + 20 µV"},{"name":"40 Hz až 10 kHz","range":"330 mV až 2 V","cmc":"0,014 % + 20 µV"},{"name":"10 kHz až 20 kHz","range":"330 mV až 2 V","cmc":"0,019 % + 60 µV"},{"name":"20 kHz až 30 kHz","range":"330 mV až 2 V","cmc":"0,018 % + 80 µV"},{"name":"30 kHz až 50 kHz","range":"330 mV až 2 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz až 100 kHz","range":"330 mV až 2 V","cmc":"0,030 % + 80 µV"},{"name":"100 kHz až 300 kHz","range":"330 mV až 2 V","cmc":"0,10 % + 0,4 mV"},{"name":"300 kHz až 500 kHz","range":"330 mV až 2 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz až 1 MHz","range":"330 mV až 2 V","cmc":"0,60 % + 2 mV"},{"name":"10 Hz až 40 Hz","range":"2 V až 3,3 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz až 10 kHz","range":"2 V až 3,3 V","cmc":"0,015 % + 60 µV"},{"name":"10 kHz až 30 kHz","range":"2 V až 3,3 V","cmc":"0,019 % + 60 µV"},{"name":"30 kHz až 50 kHz","range":"2 V až 3,3 V","cmc":"0,030 % + 50 µV"},{"name":"50 kHz až 100 kHz","range":"2 V až 3,3 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz až 300 kHz","range":"2 V až 3,3 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz až 500 kHz","range":"2 V až 3,3 V","cmc":"0,24 % + 0,6 mV"},{"name":"500 kHz až 1 MHz","range":"2 V až 3,3 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz až 40 Hz","range":"3,3 V až 20 V","cmc":"0,019 % + 0,2 mV"},{"name":"40 Hz až 10 kHz","range":"3,3 V až 20 V","cmc":"0,014 % + 0,2 mV"},{"name":"10 kHz až 30 kHz","range":"3,3 V až 20 V","cmc":"0,018 % + 0,8 mV"},{"name":"30 kHz až 100 kHz","range":"3,3 V až 20 V","cmc":"0,030 % + 0,8 mV"},{"name":"100 kHz až 300 kHz","range":"3,3 V až 20 V","cmc":"0,10 % + 4 mV"},{"name":"300 kHz až 1 MHz","range":"3,3 V až 20 V","cmc":"0,60 % + 20 mV"},{"name":"10 Hz až 40 Hz","range":"20 V až 33 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz až 10 kHz","range":"20 V až 33 V","cmc":"0,015 % + 0,6 mV"},{"name":"10 kHz až 20 kHz","range":"20 V až 33 V","cmc":"0,024 % + 0,6 mV"},{"name":"20 kHz až 30 kHz","range":"20 V až 33 V","cmc":"0,025 % + 4 mV"},{"name":"30 kHz až 50 kHz","range":"20 V až 33 V","cmc":"0,035 % + 0,6 mV"},{"name":"50 kHz až 100 kHz","range":"20 V až 33 V","cmc":"0,032 % + 8 mV"},{"name":"10 Hz až 40 Hz","range":"33 V až 200 V","cmc":"0,019 % + 2 mV"},{"name":"40 Hz až 10 kHz","range":"33 V až 200 V","cmc":"0,014 % + 2 mV"},{"name":"10 kHz až 30 kHz","range":"33 V až 200 V","cmc":"0,019 % + 8 mV"},{"name":"30 kHz až 50 kHz","range":"33 V až 200 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz až 100 kHz","range":"33 V až 200 V","cmc":"0,032 % + 8 mV"},{"name":"45 Hz až 10 kHz","range":"200 V až 330 V","cmc":"0,017 % + 10 mV"},{"name":"10 kHz až 20 kHz","range":"200 V až 330 V","cmc":"0,025 % + 6 mV"},{"name":"20 kHz až 50 kHz","range":"200 V až 330 V","cmc":"0,030 % + 6 mV"},{"name":"50 kHz až 100 kHz","range":"200 V až 330 V","cmc":"0,20 % + 50 mV"},{"name":"45 Hz až 10 kHz","range":"330 V až 500 V","cmc":"0,026 % + 10 mV"},{"name":"10 kHz až 30 kHz","range":"330 V až 500 V","cmc":"0,037 % + 20 mV"},{"name":"45 Hz až 1 kHz","range":"500 V až 1100 V","cmc":"0,030 % + 10 mV"},{"name":"1 kHz až 5 kHz","range":"500 V až 1100 V","cmc":"0,025 % + 10 mV"},{"name":"5 kHz až 10 kHz","range":"500 V až 1100 V","cmc":"0,030 % + 10 mV"},{"name":"10 kHz až 30 kHz","range":"500 V až 1100 V","cmc":"0,037 % + 50 mV"}],"technique":"Multimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter or calibrator: comparison or direct measurement","technique_zh":"标准万用表或校准器：比较或直接测量","technique_cs":"Etalonový multimetr nebo kalibrátor: porovnání nebo přímé měření","techniques":["Multimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter or calibrator: comparison or direct measurement"],"techniques_zh":["标准万用表或校准器：比较或直接测量"],"techniques_cs":["Etalonový multimetr nebo kalibrátor: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 0,1 mV do 33 mV CMC 0,027 % + 4 µV\n40 Hz do 10 kHz od 0,1 mV do 33 mV CMC 0,023 % + 4 µV\n10 kHz do 20 kHz od 0,1 mV do 33 mV CMC 0,020 % + 6 µV\n20 kHz do 30 kHz od 0,1 mV do 33 mV CMC 0,043 % + 8 µV\n30 kHz do 50 kHz od 0,1 mV do 33 mV CMC 0,10 % + 6 µV\n50 kHz do 100 kHz od 0,1 mV do 33 mV CMC 0,081 % + 20 µV\n100 kHz do 300 kHz od 0,1 mV do 33 mV CMC 0,21 % + 60 µV\n300 kHz do 500 kHz od 0,1 mV do 33 mV CMC 0,80 % + 50 µV\n500 kHz do 1 MHz od 0,1 mV do 33 mV CMC 0,61 % + 0,4 mV\n10 Hz do 40 Hz od 33 mV do 200 mV CMC 0,027 % + 4 µV\n40 Hz do 10 kHz od 33 mV do 200 mV CMC 0,015 % + 8 µV\n10 kHz do 20 kHz od 33 mV do 200 mV CMC 0,016 % + 8 µV\n20 kHz do 50 kHz od 33 mV do 200 mV CMC 0,035 % + 8 µV\n50 kHz do 100 kHz od 33 mV do 200 mV CMC 0,081 % + 20 µV\n100 kHz do 300 kHz od 33 mV do 200 mV CMC 0,21 % + 60 µV\n300 kHz do 500 kHz od 33 mV do 200 mV CMC 0,20 % + 70 µV\n500 kHz do 1 MHz od 33 mV do 200 mV CMC 0,61 % + 0,4 mV\n10 Hz do 40 Hz od 200 mV do 330 mV CMC 0,019 % + 20 µV\n40 Hz do 10 kHz od 200 mV do 330 mV CMC 0,015 % + 8 µV\n10 kHz do 20 kHz od 200 mV do 330 mV CMC 0,016 % + 8 µV\n20 kHz do 30 kHz od 200 mV do 330 mV CMC 0,025 % + 40 µV\n30 kHz do 50 kHz od 200 mV do 330 mV CMC 0,035 % + 8 µV\n50 kHz do 100 kHz od 200 mV do 330 mV CMC 0,030 % + 80 µV\n100 kHz do 500 kHz od 200 mV do 330 mV CMC 0,20 % + 70 µV\n500 kHz do 1 MHz od 200 mV do 330 mV CMC 0,60 % + 2 mV\n10 Hz do 40 Hz od 330 mV do 2 V CMC 0,019 % + 20 µV\n40 Hz do 10 kHz od 330 mV do 2 V CMC 0,014 % + 20 µV\n10 kHz do 20 kHz od 330 mV do 2 V CMC 0,019 % + 60 µV\n20 kHz do 30 kHz od 330 mV do 2 V CMC 0,018 % + 80 µV\n30 kHz do 50 kHz od 330 mV do 2 V CMC 0,030 % + 50 µV\n50 kHz do 100 kHz od 330 mV do 2 V CMC 0,030 % + 80 µV\n100 kHz do 300 kHz od 330 mV do 2 V CMC 0,10 % + 0,4 mV\n300 kHz do 500 kHz od 330 mV do 2 V CMC 0,24 % + 0,6 mV\n500 kHz do 1 MHz od 330 mV do 2 V CMC 0,60 % + 2 mV\n10 Hz do 40 Hz od 2 V do 3,3 V CMC 0,019 % + 0,2 mV\n40 Hz do 10 kHz od 2 V do 3,3 V CMC 0,015 % + 60 µV\n10 kHz do 30 kHz od 2 V do 3,3 V CMC 0,019 % + 60 µV\n30 kHz do 50 kHz od 2 V do 3,3 V CMC 0,030 % + 50 µV\n50 kHz do 100 kHz od 2 V do 3,3 V CMC 0,030 % + 0,8 mV\n100 kHz do 300 kHz od 2 V do 3,3 V CMC 0,10 % + 4 mV\n300 kHz do 500 kHz od 2 V do 3,3 V CMC 0,24 % + 0,6 mV\n500 kHz do 1 MHz od 2 V do 3,3 V CMC 0,60 % + 20 mV\n10 Hz do 40 Hz od 3,3 V do 20 V CMC 0,019 % + 0,2 mV\n40 Hz do 10 kHz od 3,3 V do 20 V CMC 0,014 % + 0,2 mV\n10 kHz do 30 kHz od 3,3 V do 20 V CMC 0,018 % + 0,8 mV\n30 kHz do 100 kHz od 3,3 V do 20 V CMC 0,030 % + 0,8 mV\n100 kHz do 300 kHz od 3,3 V do 20 V CMC 0,10 % + 4 mV\n300 kHz do 1 MHz od 3,3 V do 20 V CMC 0,60 % + 20 mV\n10 Hz do 40 Hz od 20 V do 33 V CMC 0,019 % + 2 mV\n40 Hz do 10 kHz od 20 V do 33 V CMC 0,015 % + 0,6 mV\n10 kHz do 20 kHz od 20 V do 33 V CMC 0,024 % + 0,6 mV\n20 kHz do 30 kHz od 20 V do 33 V CMC 0,025 % + 4 mV\n30 kHz do 50 kHz od 20 V do 33 V CMC 0,035 % + 0,6 mV\n50 kHz do 100 kHz od 20 V do 33 V CMC 0,032 % + 8 mV\n10 Hz do 40 Hz od 33 V do 200 V CMC 0,019 % + 2 mV\n40 Hz do 10 kHz od 33 V do 200 V CMC 0,014 % + 2 mV\n10 kHz do 30 kHz od 33 V do 200 V CMC 0,019 % + 8 mV\n30 kHz do 50 kHz od 33 V do 200 V CMC 0,030 % + 6 mV\n50 kHz do 100 kHz od 33 V do 200 V CMC 0,032 % + 8 mV\n45 Hz do 10 kHz od 200 V do 330 V CMC 0,017 % + 10 mV\n10 kHz do 20 kHz od 200 V do 330 V CMC 0,025 % + 6 mV\n20 kHz do 50 kHz od 200 V do 330 V CMC 0,030 % + 6 mV\n50 kHz do 100 kHz od 200 V do 330 V CMC 0,20 % + 50 mV\n45 Hz do 10 kHz od 330 V do 500 V CMC 0,026 % + 10 mV\n10 kHz do 30 kHz od 330 V do 500 V CMC 0,037 % + 20 mV\n45 Hz do 1 kHz od 500 V do 1100 V CMC 0,030 % + 10 mV\n1 kHz do 5 kHz od 500 V do 1100 V CMC 0,025 % + 10 mV\n5 kHz do 10 kHz od 500 V do 1100 V CMC 0,030 % + 10 mV\n10 kHz do 30 kHz od 500 V do 1100 V CMC 0,037 % + 50 mV\nMultimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK4, MK8, MK9","norm_bases":["MK4","MK8","MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / multimetry, woltomierze, testery, przetworniki, źródła i kalibratory napięcia Wzorcowanie – wielkości elektryczne Multimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni 10 Hz do 40 Hz od 0,1 mV do 33 mV CMC 0,027 % + 4 µV 40 Hz do 10 kHz od 0,1 mV do 33 mV CMC 0,023 % + 4 µV 10 kHz do 20 kHz od 0,1 mV do 33 mV CMC 0,020 % + 6 µV 20 kHz do 30 kHz od 0,1 mV do 33 mV CMC 0,043 % + 8 µV 30 kHz do 50 kHz od 0,1 mV do 33 mV CMC 0,10 % + 6 µV 50 kHz do 100 kHz od 0,1 mV do 33 mV CMC 0,081 % + 20 µV 100 kHz do 300 kHz od 0,1 mV do 33 mV CMC 0,21 % + 60 µV 300 kHz do 500 kHz od 0,1 mV do 33 mV CMC 0,80 % + 50 µV 500 kHz do 1 MHz od 0,1 mV do 33 mV CMC 0,61 % + 0,4 mV 10 Hz do 40 Hz od 33 mV do 200 mV CMC 0,027 % + 4 µV 40 Hz do 10 kHz od 33 mV do 200 mV CMC 0,015 % + 8 µV 10 kHz do 20 kHz od 33 mV do 200 mV CMC 0,016 % + 8 µV 20 kHz do 50 kHz od 33 mV do 200 mV CMC 0,035 % + 8 µV 50 kHz do 100 kHz od 33 mV do 200 mV CMC 0,081 % + 20 µV 100 kHz do 300 kHz od 33 mV do 200 mV CMC 0,21 % + 60 µV 300 kHz do 500 kHz od 33 mV do 200 mV CMC 0,20 % + 70 µV 500 kHz do 1 MHz od 33 mV do 200 mV CMC 0,61 % + 0,4 mV 10 Hz do 40 Hz od 200 mV do 330 mV CMC 0,019 % + 20 µV 40 Hz do 10 kHz od 200 mV do 330 mV CMC 0,015 % + 8 µV 10 kHz do 20 kHz od 200 mV do 330 mV CMC 0,016 % + 8 µV 20 kHz do 30 kHz od 200 mV do 330 mV CMC 0,025 % + 40 µV 30 kHz do 50 kHz od 200 mV do 330 mV CMC 0,035 % + 8 µV 50 kHz do 100 kHz od 200 mV do 330 mV CMC 0,030 % + 80 µV 100 kHz do 500 kHz od 200 mV do 330 mV CMC 0,20 % + 70 µV 500 kHz do 1 MHz od 200 mV do 330 mV CMC 0,60 % + 2 mV 10 Hz do 40 Hz od 330 mV do 2 V CMC 0,019 % + 20 µV 40 Hz do 10 kHz od 330 mV do 2 V CMC 0,014 % + 20 µV 10 kHz do 20 kHz od 330 mV do 2 V CMC 0,019 % + 60 µV 20 kHz do 30 kHz od 330 mV do 2 V CMC 0,018 % + 80 µV 30 kHz do 50 kHz od 330 mV do 2 V CMC 0,030 % + 50 µV 50 kHz do 100 kHz od 330 mV do 2 V CMC 0,030 % + 80 µV 100 kHz do 300 kHz od 330 mV do 2 V CMC 0,10 % + 0,4 mV 300 kHz do 500 kHz od 330 mV do 2 V CMC 0,24 % + 0,6 mV 500 kHz do 1 MHz od 330 mV do 2 V CMC 0,60 % + 2 mV 10 Hz do 40 Hz od 2 V do 3,3 V CMC 0,019 % + 0,2 mV 40 Hz do 10 kHz od 2 V do 3,3 V CMC 0,015 % + 60 µV 10 kHz do 30 kHz od 2 V do 3,3 V CMC 0,019 % + 60 µV 30 kHz do 50 kHz od 2 V do 3,3 V CMC 0,030 % + 50 µV 50 kHz do 100 kHz od 2 V do 3,3 V CMC 0,030 % + 0,8 mV 100 kHz do 300 kHz od 2 V do 3,3 V CMC 0,10 % + 4 mV 300 kHz do 500 kHz od 2 V do 3,3 V CMC 0,24 % + 0,6 mV 500 kHz do 1 MHz od 2 V do 3,3 V CMC 0,60 % + 20 mV 10 Hz do 40 Hz od 3,3 V do 20 V CMC 0,019 % + 0,2 mV 40 Hz do 10 kHz od 3,3 V do 20 V CMC 0,014 % + 0,2 mV 10 kHz do 30 kHz od 3,3 V do 20 V CMC 0,018 % + 0,8 mV 30 kHz do 100 kHz od 3,3 V do 20 V CMC 0,030 % + 0,8 mV 100 kHz do 300 kHz od 3,3 V do 20 V CMC 0,10 % + 4 mV 300 kHz do 1 MHz od 3,3 V do 20 V CMC 0,60 % + 20 mV 10 Hz do 40 Hz od 20 V do 33 V CMC 0,019 % + 2 mV 40 Hz do 10 kHz od 20 V do 33 V CMC 0,015 % + 0,6 mV 10 kHz do 20 kHz od 20 V do 33 V CMC 0,024 % + 0,6 mV 20 kHz do 30 kHz od 20 V do 33 V CMC 0,025 % + 4 mV 30 kHz do 50 kHz od 20 V do 33 V CMC 0,035 % + 0,6 mV 50 kHz do 100 kHz od 20 V do 33 V CMC 0,032 % + 8 mV 10 Hz do 40 Hz od 33 V do 200 V CMC 0,019 % + 2 mV 40 Hz do 10 kHz od 33 V do 200 V CMC 0,014 % + 2 mV 10 kHz do 30 kHz od 33 V do 200 V CMC 0,019 % + 8 mV 30 kHz do 50 kHz od 33 V do 200 V CMC 0,030 % + 6 mV 50 kHz do 100 kHz od 33 V do 200 V CMC 0,032 % + 8 mV 45 Hz do 10 kHz od 200 V do 330 V CMC 0,017 % + 10 mV 10 kHz do 20 kHz od 200 V do 330 V CMC 0,025 % + 6 mV 20 kHz do 50 kHz od 200 V do 330 V CMC 0,030 % + 6 mV 50 kHz do 100 kHz od 200 V do 330 V CMC 0,20 % + 50 mV 45 Hz do 10 kHz od 330 V do 500 V CMC 0,026 % + 10 mV 10 kHz do 30 kHz od 330 V do 500 V CMC 0,037 % + 20 mV 45 Hz do 1 kHz od 500 V do 1100 V CMC 0,030 % + 10 mV 1 kHz do 5 kHz od 500 V do 1100 V CMC 0,025 % + 10 mV 5 kHz do 10 kHz od 500 V do 1100 V CMC 0,030 % + 10 mV 10 kHz do 30 kHz od 500 V do 1100 V CMC 0,037 % + 50 mV Střídavé napětí / Multimetry, voltmetry, testery, převodníky, zdroje a kalibrátory napětí Kalibrace – elektrické veličiny Etalonový multimetr nebo kalibrátor: porovnání nebo přímé měření 10 Hz až 40 Hz 0,1 mV až 33 mV CMC 0,027 % + 4 µV 40 Hz až 10 kHz 0,1 mV až 33 mV CMC 0,023 % + 4 µV 10 kHz až 20 kHz 0,1 mV až 33 mV CMC 0,020 % + 6 µV 20 kHz až 30 kHz 0,1 mV až 33 mV CMC 0,043 % + 8 µV 30 kHz až 50 kHz 0,1 mV až 33 mV CMC 0,10 % + 6 µV 50 kHz až 100 kHz 0,1 mV až 33 mV CMC 0,081 % + 20 µV 100 kHz až 300 kHz 0,1 mV až 33 mV CMC 0,21 % + 60 µV 300 kHz až 500 kHz 0,1 mV až 33 mV CMC 0,80 % + 50 µV 500 kHz až 1 MHz 0,1 mV až 33 mV CMC 0,61 % + 0,4 mV 10 Hz až 40 Hz 33 mV až 200 mV CMC 0,027 % + 4 µV 40 Hz až 10 kHz 33 mV až 200 mV CMC 0,015 % + 8 µV 10 kHz až 20 kHz 33 mV až 200 mV CMC 0,016 % + 8 µV 20 kHz až 50 kHz 33 mV až 200 mV CMC 0,035 % + 8 µV 50 kHz až 100 kHz 33 mV až 200 mV CMC 0,081 % + 20 µV 100 kHz až 300 kHz 33 mV až 200 mV CMC 0,21 % + 60 µV 300 kHz až 500 kHz 33 mV až 200 mV CMC 0,20 % + 70 µV 500 kHz až 1 MHz 33 mV až 200 mV CMC 0,61 % + 0,4 mV 10 Hz až 40 Hz 200 mV až 330 mV CMC 0,019 % + 20 µV 40 Hz až 10 kHz 200 mV až 330 mV CMC 0,015 % + 8 µV 10 kHz až 20 kHz 200 mV až 330 mV CMC 0,016 % + 8 µV 20 kHz až 30 kHz 200 mV až 330 mV CMC 0,025 % + 40 µV 30 kHz až 50 kHz 200 mV až 330 mV CMC 0,035 % + 8 µV 50 kHz až 100 kHz 200 mV až 330 mV CMC 0,030 % + 80 µV 100 kHz až 500 kHz 200 mV až 330 mV CMC 0,20 % + 70 µV 500 kHz až 1 MHz 200 mV až 330 mV CMC 0,60 % + 2 mV 10 Hz až 40 Hz 330 mV až 2 V CMC 0,019 % + 20 µV 40 Hz až 10 kHz 330 mV až 2 V CMC 0,014 % + 20 µV 10 kHz až 20 kHz 330 mV až 2 V CMC 0,019 % + 60 µV 20 kHz až 30 kHz 330 mV až 2 V CMC 0,018 % + 80 µV 30 kHz až 50 kHz 330 mV až 2 V CMC 0,030 % + 50 µV 50 kHz až 100 kHz 330 mV až 2 V CMC 0,030 % + 80 µV 100 kHz až 300 kHz 330 mV až 2 V CMC 0,10 % + 0,4 mV 300 kHz až 500 kHz 330 mV až 2 V CMC 0,24 % + 0,6 mV 500 kHz až 1 MHz 330 mV až 2 V CMC 0,60 % + 2 mV 10 Hz až 40 Hz 2 V až 3,3 V CMC 0,019 % + 0,2 mV 40 Hz až 10 kHz 2 V až 3,3 V CMC 0,015 % + 60 µV 10 kHz až 30 kHz 2 V až 3,3 V CMC 0,019 % + 60 µV 30 kHz až 50 kHz 2 V až 3,3 V CMC 0,030 % + 50 µV 50 kHz až 100 kHz 2 V až 3,3 V CMC 0,030 % + 0,8 mV 100 kHz až 300 kHz 2 V až 3,3 V CMC 0,10 % + 4 mV 300 kHz až 500 kHz 2 V až 3,3 V CMC 0,24 % + 0,6 mV 500 kHz až 1 MHz 2 V až 3,3 V CMC 0,60 % + 20 mV 10 Hz až 40 Hz 3,3 V až 20 V CMC 0,019 % + 0,2 mV 40 Hz až 10 kHz 3,3 V až 20 V CMC 0,014 % + 0,2 mV 10 kHz až 30 kHz 3,3 V až 20 V CMC 0,018 % + 0,8 mV 30 kHz až 100 kHz 3,3 V až 20 V CMC 0,030 % + 0,8 mV 100 kHz až 300 kHz 3,3 V až 20 V CMC 0,10 % + 4 mV 300 kHz až 1 MHz 3,3 V až 20 V CMC 0,60 % + 20 mV 10 Hz až 40 Hz 20 V až 33 V CMC 0,019 % + 2 mV 40 Hz až 10 kHz 20 V až 33 V CMC 0,015 % + 0,6 mV 10 kHz až 20 kHz 20 V až 33 V CMC 0,024 % + 0,6 mV 20 kHz až 30 kHz 20 V až 33 V CMC 0,025 % + 4 mV 30 kHz až 50 kHz 20 V až 33 V CMC 0,035 % + 0,6 mV 50 kHz až 100 kHz 20 V až 33 V CMC 0,032 % + 8 mV 10 Hz až 40 Hz 33 V až 200 V CMC 0,019 % + 2 mV 40 Hz až 10 kHz 33 V až 200 V CMC 0,014 % + 2 mV 10 kHz až 30 kHz 33 V až 200 V CMC 0,019 % + 8 mV 30 kHz až 50 kHz 33 V až 200 V CMC 0,030 % + 6 mV 50 kHz až 100 kHz 33 V až 200 V CMC 0,032 % + 8 mV 45 Hz až 10 kHz 200 V až 330 V CMC 0,017 % + 10 mV 10 kHz až 20 kHz 200 V až 330 V CMC 0,025 % + 6 mV 20 kHz až 50 kHz 200 V až 330 V CMC 0,030 % + 6 mV 50 kHz až 100 kHz 200 V až 330 V CMC 0,20 % + 50 mV 45 Hz až 10 kHz 330 V až 500 V CMC 0,026 % + 10 mV 10 kHz až 30 kHz 330 V až 500 V CMC 0,037 % + 20 mV 45 Hz až 1 kHz 500 V až 1100 V CMC 0,030 % + 10 mV 1 kHz až 5 kHz 500 V až 1100 V CMC 0,025 % + 10 mV 5 kHz až 10 kHz 500 V až 1100 V CMC 0,030 % + 10 mV 10 kHz až 30 kHz 500 V až 1100 V CMC 0,037 % + 50 mV MK4, MK8, MK9 Napiecie przemienne / multimetry, woltomierze, testery, przetworniki, zrodla i kalibratory napiecia Wzorcowanie – wielkosci elektryczne Multimetr lub kalibrator wzorcowy: porownanie lub pomiar bezposredni 10 Hz do 40 Hz od 0,1 mV do 33 mV CMC 0,027 % + 4 µV 40 Hz do 10 kHz od 0,1 mV do 33 mV CMC 0,023 % + 4 µV 10 kHz do 20 kHz od 0,1 mV do 33 mV CMC 0,020 % + 6 µV 20 kHz do 30 kHz od 0,1 mV do 33 mV CMC 0,043 % + 8 µV 30 kHz do 50 kHz od 0,1 mV do 33 mV CMC 0,10 % + 6 µV 50 kHz do 100 kHz od 0,1 mV do 33 mV CMC 0,081 % + 20 µV 100 kHz do 300 kHz od 0,1 mV do 33 mV CMC 0,21 % + 60 µV 300 kHz do 500 kHz od 0,1 mV do 33 mV CMC 0,80 % + 50 µV 500 kHz do 1 MHz od 0,1 mV do 33 mV CMC 0,61 % + 0,4 mV 10 Hz do 40 Hz od 33 mV do 200 mV CMC 0,027 % + 4 µV 40 Hz do 10 kHz od 33 mV do 200 mV CMC 0,015 % + 8 µV 10 kHz do 20 kHz od 33 mV do 200 mV CMC 0,016 % + 8 µV 20 kHz do 50 kHz od 33 mV do 200 mV CMC 0,035 % + 8 µV 50 kHz do 100 kHz od 33 mV do 200 mV CMC 0,081 % + 20 µV 100 kHz do 300 kHz od 33 mV do 200 mV CMC 0,21 % + 60 µV 300 kHz do 500 kHz od 33 mV do 200 mV CMC 0,20 % + 70 µV 500 kHz do 1 MHz od 33 mV do 200 mV CMC 0,61 % + 0,4 mV 10 Hz do 40 Hz od 200 mV do 330 mV CMC 0,019 % + 20 µV 40 Hz do 10 kHz od 200 mV do 330 mV CMC 0,015 % + 8 µV 10 kHz do 20 kHz od 200 mV do 330 mV CMC 0,016 % + 8 µV 20 kHz do 30 kHz od 200 mV do 330 mV CMC 0,025 % + 40 µV 30 kHz do 50 kHz od 200 mV do 330 mV CMC 0,035 % + 8 µV 50 kHz do 100 kHz od 200 mV do 330 mV CMC 0,030 % + 80 µV 100 kHz do 500 kHz od 200 mV do 330 mV CMC 0,20 % + 70 µV 500 kHz do 1 MHz od 200 mV do 330 mV CMC 0,60 % + 2 mV 10 Hz do 40 Hz od 330 mV do 2 V CMC 0,019 % + 20 µV 40 Hz do 10 kHz od 330 mV do 2 V CMC 0,014 % + 20 µV 10 kHz do 20 kHz od 330 mV do 2 V CMC 0,019 % + 60 µV 20 kHz do 30 kHz od 330 mV do 2 V CMC 0,018 % + 80 µV 30 kHz do 50 kHz od 330 mV do 2 V CMC 0,030 % + 50 µV 50 kHz do 100 kHz od 330 mV do 2 V CMC 0,030 % + 80 µV 100 kHz do 300 kHz od 330 mV do 2 V CMC 0,10 % + 0,4 mV 300 kHz do 500 kHz od 330 mV do 2 V CMC 0,24 % + 0,6 mV 500 kHz do 1 MHz od 330 mV do 2 V CMC 0,60 % + 2 mV 10 Hz do 40 Hz od 2 V do 3,3 V CMC 0,019 % + 0,2 mV 40 Hz do 10 kHz od 2 V do 3,3 V CMC 0,015 % + 60 µV 10 kHz do 30 kHz od 2 V do 3,3 V CMC 0,019 % + 60 µV 30 kHz do 50 kHz od 2 V do 3,3 V CMC 0,030 % + 50 µV 50 kHz do 100 kHz od 2 V do 3,3 V CMC 0,030 % + 0,8 mV 100 kHz do 300 kHz od 2 V do 3,3 V CMC 0,10 % + 4 mV 300 kHz do 500 kHz od 2 V do 3,3 V CMC 0,24 % + 0,6 mV 500 kHz do 1 MHz od 2 V do 3,3 V CMC 0,60 % + 20 mV 10 Hz do 40 Hz od 3,3 V do 20 V CMC 0,019 % + 0,2 mV 40 Hz do 10 kHz od 3,3 V do 20 V CMC 0,014 % + 0,2 mV 10 kHz do 30 kHz od 3,3 V do 20 V CMC 0,018 % + 0,8 mV 30 kHz do 100 kHz od 3,3 V do 20 V CMC 0,030 % + 0,8 mV 100 kHz do 300 kHz od 3,3 V do 20 V CMC 0,10 % + 4 mV 300 kHz do 1 MHz od 3,3 V do 20 V CMC 0,60 % + 20 mV 10 Hz do 40 Hz od 20 V do 33 V CMC 0,019 % + 2 mV 40 Hz do 10 kHz od 20 V do 33 V CMC 0,015 % + 0,6 mV 10 kHz do 20 kHz od 20 V do 33 V CMC 0,024 % + 0,6 mV 20 kHz do 30 kHz od 20 V do 33 V CMC 0,025 % + 4 mV 30 kHz do 50 kHz od 20 V do 33 V CMC 0,035 % + 0,6 mV 50 kHz do 100 kHz od 20 V do 33 V CMC 0,032 % + 8 mV 10 Hz do 40 Hz od 33 V do 200 V CMC 0,019 % + 2 mV 40 Hz do 10 kHz od 33 V do 200 V CMC 0,014 % + 2 mV 10 kHz do 30 kHz od 33 V do 200 V CMC 0,019 % + 8 mV 30 kHz do 50 kHz od 33 V do 200 V CMC 0,030 % + 6 mV 50 kHz do 100 kHz od 33 V do 200 V CMC 0,032 % + 8 mV 45 Hz do 10 kHz od 200 V do 330 V CMC 0,017 % + 10 mV 10 kHz do 20 kHz od 200 V do 330 V CMC 0,025 % + 6 mV 20 kHz do 50 kHz od 200 V do 330 V CMC 0,030 % + 6 mV 50 kHz do 100 kHz od 200 V do 330 V CMC 0,20 % + 50 mV 45 Hz do 10 kHz od 330 V do 500 V CMC 0,026 % + 10 mV 10 kHz do 30 kHz od 330 V do 500 V CMC 0,037 % + 20 mV 45 Hz do 1 kHz od 500 V do 1100 V CMC 0,030 % + 10 mV 1 kHz do 5 kHz od 500 V do 1100 V CMC 0,025 % + 10 mV 5 kHz do 10 kHz od 500 V do 1100 V CMC 0,030 % + 10 mV 10 kHz do 30 kHz od 500 V do 1100 V CMC 0,037 % + 50 mV Stridave napeti / Multimetry, voltmetry, testery, prevodniky, zdroje a kalibratory napeti Kalibrace – elektricke veliciny Etalonovy multimetr nebo kalibrator: porovnani nebo prime mereni 10 Hz az 40 Hz 0,1 mV az 33 mV CMC 0,027 % + 4 µV 40 Hz az 10 kHz 0,1 mV az 33 mV CMC 0,023 % + 4 µV 10 kHz az 20 kHz 0,1 mV az 33 mV CMC 0,020 % + 6 µV 20 kHz az 30 kHz 0,1 mV az 33 mV CMC 0,043 % + 8 µV 30 kHz az 50 kHz 0,1 mV az 33 mV CMC 0,10 % + 6 µV 50 kHz az 100 kHz 0,1 mV az 33 mV CMC 0,081 % + 20 µV 100 kHz az 300 kHz 0,1 mV az 33 mV CMC 0,21 % + 60 µV 300 kHz az 500 kHz 0,1 mV az 33 mV CMC 0,80 % + 50 µV 500 kHz az 1 MHz 0,1 mV az 33 mV CMC 0,61 % + 0,4 mV 10 Hz az 40 Hz 33 mV az 200 mV CMC 0,027 % + 4 µV 40 Hz az 10 kHz 33 mV az 200 mV CMC 0,015 % + 8 µV 10 kHz az 20 kHz 33 mV az 200 mV CMC 0,016 % + 8 µV 20 kHz az 50 kHz 33 mV az 200 mV CMC 0,035 % + 8 µV 50 kHz az 100 kHz 33 mV az 200 mV CMC 0,081 % + 20 µV 100 kHz az 300 kHz 33 mV az 200 mV CMC 0,21 % + 60 µV 300 kHz az 500 kHz 33 mV az 200 mV CMC 0,20 % + 70 µV 500 kHz az 1 MHz 33 mV az 200 mV CMC 0,61 % + 0,4 mV 10 Hz az 40 Hz 200 mV az 330 mV CMC 0,019 % + 20 µV 40 Hz az 10 kHz 200 mV az 330 mV CMC 0,015 % + 8 µV 10 kHz az 20 kHz 200 mV az 330 mV CMC 0,016 % + 8 µV 20 kHz az 30 kHz 200 mV az 330 mV CMC 0,025 % + 40 µV 30 kHz az 50 kHz 200 mV az 330 mV CMC 0,035 % + 8 µV 50 kHz az 100 kHz 200 mV az 330 mV CMC 0,030 % + 80 µV 100 kHz az 500 kHz 200 mV az 330 mV CMC 0,20 % + 70 µV 500 kHz az 1 MHz 200 mV az 330 mV CMC 0,60 % + 2 mV 10 Hz az 40 Hz 330 mV az 2 V CMC 0,019 % + 20 µV 40 Hz az 10 kHz 330 mV az 2 V CMC 0,014 % + 20 µV 10 kHz az 20 kHz 330 mV az 2 V CMC 0,019 % + 60 µV 20 kHz az 30 kHz 330 mV az 2 V CMC 0,018 % + 80 µV 30 kHz az 50 kHz 330 mV az 2 V CMC 0,030 % + 50 µV 50 kHz az 100 kHz 330 mV az 2 V CMC 0,030 % + 80 µV 100 kHz az 300 kHz 330 mV az 2 V CMC 0,10 % + 0,4 mV 300 kHz az 500 kHz 330 mV az 2 V CMC 0,24 % + 0,6 mV 500 kHz az 1 MHz 330 mV az 2 V CMC 0,60 % + 2 mV 10 Hz az 40 Hz 2 V az 3,3 V CMC 0,019 % + 0,2 mV 40 Hz az 10 kHz 2 V az 3,3 V CMC 0,015 % + 60 µV 10 kHz az 30 kHz 2 V az 3,3 V CMC 0,019 % + 60 µV 30 kHz az 50 kHz 2 V az 3,3 V CMC 0,030 % + 50 µV 50 kHz az 100 kHz 2 V az 3,3 V CMC 0,030 % + 0,8 mV 100 kHz az 300 kHz 2 V az 3,3 V CMC 0,10 % + 4 mV 300 kHz az 500 kHz 2 V az 3,3 V CMC 0,24 % + 0,6 mV 500 kHz az 1 MHz 2 V az 3,3 V CMC 0,60 % + 20 mV 10 Hz az 40 Hz 3,3 V az 20 V CMC 0,019 % + 0,2 mV 40 Hz az 10 kHz 3,3 V az 20 V CMC 0,014 % + 0,2 mV 10 kHz az 30 kHz 3,3 V az 20 V CMC 0,018 % + 0,8 mV 30 kHz az 100 kHz 3,3 V az 20 V CMC 0,030 % + 0,8 mV 100 kHz az 300 kHz 3,3 V az 20 V CMC 0,10 % + 4 mV 300 kHz az 1 MHz 3,3 V az 20 V CMC 0,60 % + 20 mV 10 Hz az 40 Hz 20 V az 33 V CMC 0,019 % + 2 mV 40 Hz az 10 kHz 20 V az 33 V CMC 0,015 % + 0,6 mV 10 kHz az 20 kHz 20 V az 33 V CMC 0,024 % + 0,6 mV 20 kHz az 30 kHz 20 V az 33 V CMC 0,025 % + 4 mV 30 kHz az 50 kHz 20 V az 33 V CMC 0,035 % + 0,6 mV 50 kHz az 100 kHz 20 V az 33 V CMC 0,032 % + 8 mV 10 Hz az 40 Hz 33 V az 200 V CMC 0,019 % + 2 mV 40 Hz az 10 kHz 33 V az 200 V CMC 0,014 % + 2 mV 10 kHz az 30 kHz 33 V az 200 V CMC 0,019 % + 8 mV 30 kHz az 50 kHz 33 V az 200 V CMC 0,030 % + 6 mV 50 kHz az 100 kHz 33 V az 200 V CMC 0,032 % + 8 mV 45 Hz az 10 kHz 200 V az 330 V CMC 0,017 % + 10 mV 10 kHz az 20 kHz 200 V az 330 V CMC 0,025 % + 6 mV 20 kHz az 50 kHz 200 V az 330 V CMC 0,030 % + 6 mV 50 kHz az 100 kHz 200 V az 330 V CMC 0,20 % + 50 mV 45 Hz az 10 kHz 330 V az 500 V CMC 0,026 % + 10 mV 10 kHz az 30 kHz 330 V az 500 V CMC 0,037 % + 20 mV 45 Hz az 1 kHz 500 V az 1100 V CMC 0,030 % + 10 mV 1 kHz az 5 kHz 500 V az 1100 V CMC 0,025 % + 10 mV 5 kHz az 10 kHz 500 V az 1100 V CMC 0,030 % + 10 mV 10 kHz az 30 kHz 500 V az 1100 V CMC 0,037 % + 50 mV MK4, MK8, MK9","search_en":"AC voltage / Multimeters, voltmeters, testers, transducers, voltage sources and calibrators Calibration – electrical quantities Standard multimeter or calibrator: comparison or direct measurement 10 Hz to 40 Hz 0,1 mV to 33 mV CMC 0,027 % + 4 µV 40 Hz to 10 kHz 0,1 mV to 33 mV CMC 0,023 % + 4 µV 10 kHz to 20 kHz 0,1 mV to 33 mV CMC 0,020 % + 6 µV 20 kHz to 30 kHz 0,1 mV to 33 mV CMC 0,043 % + 8 µV 30 kHz to 50 kHz 0,1 mV to 33 mV CMC 0,10 % + 6 µV 50 kHz to 100 kHz 0,1 mV to 33 mV CMC 0,081 % + 20 µV 100 kHz to 300 kHz 0,1 mV to 33 mV CMC 0,21 % + 60 µV 300 kHz to 500 kHz 0,1 mV to 33 mV CMC 0,80 % + 50 µV 500 kHz to 1 MHz 0,1 mV to 33 mV CMC 0,61 % + 0,4 mV 10 Hz to 40 Hz 33 mV to 200 mV CMC 0,027 % + 4 µV 40 Hz to 10 kHz 33 mV to 200 mV CMC 0,015 % + 8 µV 10 kHz to 20 kHz 33 mV to 200 mV CMC 0,016 % + 8 µV 20 kHz to 50 kHz 33 mV to 200 mV CMC 0,035 % + 8 µV 50 kHz to 100 kHz 33 mV to 200 mV CMC 0,081 % + 20 µV 100 kHz to 300 kHz 33 mV to 200 mV CMC 0,21 % + 60 µV 300 kHz to 500 kHz 33 mV to 200 mV CMC 0,20 % + 70 µV 500 kHz to 1 MHz 33 mV to 200 mV CMC 0,61 % + 0,4 mV 10 Hz to 40 Hz 200 mV to 330 mV CMC 0,019 % + 20 µV 40 Hz to 10 kHz 200 mV to 330 mV CMC 0,015 % + 8 µV 10 kHz to 20 kHz 200 mV to 330 mV CMC 0,016 % + 8 µV 20 kHz to 30 kHz 200 mV to 330 mV CMC 0,025 % + 40 µV 30 kHz to 50 kHz 200 mV to 330 mV CMC 0,035 % + 8 µV 50 kHz to 100 kHz 200 mV to 330 mV CMC 0,030 % + 80 µV 100 kHz to 500 kHz 200 mV to 330 mV CMC 0,20 % + 70 µV 500 kHz to 1 MHz 200 mV to 330 mV CMC 0,60 % + 2 mV 10 Hz to 40 Hz 330 mV to 2 V CMC 0,019 % + 20 µV 40 Hz to 10 kHz 330 mV to 2 V CMC 0,014 % + 20 µV 10 kHz to 20 kHz 330 mV to 2 V CMC 0,019 % + 60 µV 20 kHz to 30 kHz 330 mV to 2 V CMC 0,018 % + 80 µV 30 kHz to 50 kHz 330 mV to 2 V CMC 0,030 % + 50 µV 50 kHz to 100 kHz 330 mV to 2 V CMC 0,030 % + 80 µV 100 kHz to 300 kHz 330 mV to 2 V CMC 0,10 % + 0,4 mV 300 kHz to 500 kHz 330 mV to 2 V CMC 0,24 % + 0,6 mV 500 kHz to 1 MHz 330 mV to 2 V CMC 0,60 % + 2 mV 10 Hz to 40 Hz 2 V to 3,3 V CMC 0,019 % + 0,2 mV 40 Hz to 10 kHz 2 V to 3,3 V CMC 0,015 % + 60 µV 10 kHz to 30 kHz 2 V to 3,3 V CMC 0,019 % + 60 µV 30 kHz to 50 kHz 2 V to 3,3 V CMC 0,030 % + 50 µV 50 kHz to 100 kHz 2 V to 3,3 V CMC 0,030 % + 0,8 mV 100 kHz to 300 kHz 2 V to 3,3 V CMC 0,10 % + 4 mV 300 kHz to 500 kHz 2 V to 3,3 V CMC 0,24 % + 0,6 mV 500 kHz to 1 MHz 2 V to 3,3 V CMC 0,60 % + 20 mV 10 Hz to 40 Hz 3,3 V to 20 V CMC 0,019 % + 0,2 mV 40 Hz to 10 kHz 3,3 V to 20 V CMC 0,014 % + 0,2 mV 10 kHz to 30 kHz 3,3 V to 20 V CMC 0,018 % + 0,8 mV 30 kHz to 100 kHz 3,3 V to 20 V CMC 0,030 % + 0,8 mV 100 kHz to 300 kHz 3,3 V to 20 V CMC 0,10 % + 4 mV 300 kHz to 1 MHz 3,3 V to 20 V CMC 0,60 % + 20 mV 10 Hz to 40 Hz 20 V to 33 V CMC 0,019 % + 2 mV 40 Hz to 10 kHz 20 V to 33 V CMC 0,015 % + 0,6 mV 10 kHz to 20 kHz 20 V to 33 V CMC 0,024 % + 0,6 mV 20 kHz to 30 kHz 20 V to 33 V CMC 0,025 % + 4 mV 30 kHz to 50 kHz 20 V to 33 V CMC 0,035 % + 0,6 mV 50 kHz to 100 kHz 20 V to 33 V CMC 0,032 % + 8 mV 10 Hz to 40 Hz 33 V to 200 V CMC 0,019 % + 2 mV 40 Hz to 10 kHz 33 V to 200 V CMC 0,014 % + 2 mV 10 kHz to 30 kHz 33 V to 200 V CMC 0,019 % + 8 mV 30 kHz to 50 kHz 33 V to 200 V CMC 0,030 % + 6 mV 50 kHz to 100 kHz 33 V to 200 V CMC 0,032 % + 8 mV 45 Hz to 10 kHz 200 V to 330 V CMC 0,017 % + 10 mV 10 kHz to 20 kHz 200 V to 330 V CMC 0,025 % + 6 mV 20 kHz to 50 kHz 200 V to 330 V CMC 0,030 % + 6 mV 50 kHz to 100 kHz 200 V to 330 V CMC 0,20 % + 50 mV 45 Hz to 10 kHz 330 V to 500 V CMC 0,026 % + 10 mV 10 kHz to 30 kHz 330 V to 500 V CMC 0,037 % + 20 mV 45 Hz to 1 kHz 500 V to 1100 V CMC 0,030 % + 10 mV 1 kHz to 5 kHz 500 V to 1100 V CMC 0,025 % + 10 mV 5 kHz to 10 kHz 500 V to 1100 V CMC 0,030 % + 10 mV 10 kHz to 30 kHz 500 V to 1100 V CMC 0,037 % + 50 mV MK4, MK8, MK9","search_zh":"交流电压 / 万用表、电压表、测试仪、变送器、电压源和校准器 校准 – 电学量 标准万用表或校准器：比较或直接测量 10 Hz 至 40 Hz 0,1 mV 至 33 mV CMC 0,027 % + 4 µV 40 Hz 至 10 kHz 0,1 mV 至 33 mV CMC 0,023 % + 4 µV 10 kHz 至 20 kHz 0,1 mV 至 33 mV CMC 0,020 % + 6 µV 20 kHz 至 30 kHz 0,1 mV 至 33 mV CMC 0,043 % + 8 µV 30 kHz 至 50 kHz 0,1 mV 至 33 mV CMC 0,10 % + 6 µV 50 kHz 至 100 kHz 0,1 mV 至 33 mV CMC 0,081 % + 20 µV 100 kHz 至 300 kHz 0,1 mV 至 33 mV CMC 0,21 % + 60 µV 300 kHz 至 500 kHz 0,1 mV 至 33 mV CMC 0,80 % + 50 µV 500 kHz 至 1 MHz 0,1 mV 至 33 mV CMC 0,61 % + 0,4 mV 10 Hz 至 40 Hz 33 mV 至 200 mV CMC 0,027 % + 4 µV 40 Hz 至 10 kHz 33 mV 至 200 mV CMC 0,015 % + 8 µV 10 kHz 至 20 kHz 33 mV 至 200 mV CMC 0,016 % + 8 µV 20 kHz 至 50 kHz 33 mV 至 200 mV CMC 0,035 % + 8 µV 50 kHz 至 100 kHz 33 mV 至 200 mV CMC 0,081 % + 20 µV 100 kHz 至 300 kHz 33 mV 至 200 mV CMC 0,21 % + 60 µV 300 kHz 至 500 kHz 33 mV 至 200 mV CMC 0,20 % + 70 µV 500 kHz 至 1 MHz 33 mV 至 200 mV CMC 0,61 % + 0,4 mV 10 Hz 至 40 Hz 200 mV 至 330 mV CMC 0,019 % + 20 µV 40 Hz 至 10 kHz 200 mV 至 330 mV CMC 0,015 % + 8 µV 10 kHz 至 20 kHz 200 mV 至 330 mV CMC 0,016 % + 8 µV 20 kHz 至 30 kHz 200 mV 至 330 mV CMC 0,025 % + 40 µV 30 kHz 至 50 kHz 200 mV 至 330 mV CMC 0,035 % + 8 µV 50 kHz 至 100 kHz 200 mV 至 330 mV CMC 0,030 % + 80 µV 100 kHz 至 500 kHz 200 mV 至 330 mV CMC 0,20 % + 70 µV 500 kHz 至 1 MHz 200 mV 至 330 mV CMC 0,60 % + 2 mV 10 Hz 至 40 Hz 330 mV 至 2 V CMC 0,019 % + 20 µV 40 Hz 至 10 kHz 330 mV 至 2 V CMC 0,014 % + 20 µV 10 kHz 至 20 kHz 330 mV 至 2 V CMC 0,019 % + 60 µV 20 kHz 至 30 kHz 330 mV 至 2 V CMC 0,018 % + 80 µV 30 kHz 至 50 kHz 330 mV 至 2 V CMC 0,030 % + 50 µV 50 kHz 至 100 kHz 330 mV 至 2 V CMC 0,030 % + 80 µV 100 kHz 至 300 kHz 330 mV 至 2 V CMC 0,10 % + 0,4 mV 300 kHz 至 500 kHz 330 mV 至 2 V CMC 0,24 % + 0,6 mV 500 kHz 至 1 MHz 330 mV 至 2 V CMC 0,60 % + 2 mV 10 Hz 至 40 Hz 2 V 至 3,3 V CMC 0,019 % + 0,2 mV 40 Hz 至 10 kHz 2 V 至 3,3 V CMC 0,015 % + 60 µV 10 kHz 至 30 kHz 2 V 至 3,3 V CMC 0,019 % + 60 µV 30 kHz 至 50 kHz 2 V 至 3,3 V CMC 0,030 % + 50 µV 50 kHz 至 100 kHz 2 V 至 3,3 V CMC 0,030 % + 0,8 mV 100 kHz 至 300 kHz 2 V 至 3,3 V CMC 0,10 % + 4 mV 300 kHz 至 500 kHz 2 V 至 3,3 V CMC 0,24 % + 0,6 mV 500 kHz 至 1 MHz 2 V 至 3,3 V CMC 0,60 % + 20 mV 10 Hz 至 40 Hz 3,3 V 至 20 V CMC 0,019 % + 0,2 mV 40 Hz 至 10 kHz 3,3 V 至 20 V CMC 0,014 % + 0,2 mV 10 kHz 至 30 kHz 3,3 V 至 20 V CMC 0,018 % + 0,8 mV 30 kHz 至 100 kHz 3,3 V 至 20 V CMC 0,030 % + 0,8 mV 100 kHz 至 300 kHz 3,3 V 至 20 V CMC 0,10 % + 4 mV 300 kHz 至 1 MHz 3,3 V 至 20 V CMC 0,60 % + 20 mV 10 Hz 至 40 Hz 20 V 至 33 V CMC 0,019 % + 2 mV 40 Hz 至 10 kHz 20 V 至 33 V CMC 0,015 % + 0,6 mV 10 kHz 至 20 kHz 20 V 至 33 V CMC 0,024 % + 0,6 mV 20 kHz 至 30 kHz 20 V 至 33 V CMC 0,025 % + 4 mV 30 kHz 至 50 kHz 20 V 至 33 V CMC 0,035 % + 0,6 mV 50 kHz 至 100 kHz 20 V 至 33 V CMC 0,032 % + 8 mV 10 Hz 至 40 Hz 33 V 至 200 V CMC 0,019 % + 2 mV 40 Hz 至 10 kHz 33 V 至 200 V CMC 0,014 % + 2 mV 10 kHz 至 30 kHz 33 V 至 200 V CMC 0,019 % + 8 mV 30 kHz 至 50 kHz 33 V 至 200 V CMC 0,030 % + 6 mV 50 kHz 至 100 kHz 33 V 至 200 V CMC 0,032 % + 8 mV 45 Hz 至 10 kHz 200 V 至 330 V CMC 0,017 % + 10 mV 10 kHz 至 20 kHz 200 V 至 330 V CMC 0,025 % + 6 mV 20 kHz 至 50 kHz 200 V 至 330 V CMC 0,030 % + 6 mV 50 kHz 至 100 kHz 200 V 至 330 V CMC 0,20 % + 50 mV 45 Hz 至 10 kHz 330 V 至 500 V CMC 0,026 % + 10 mV 10 kHz 至 30 kHz 330 V 至 500 V CMC 0,037 % + 20 mV 45 Hz 至 1 kHz 500 V 至 1100 V CMC 0,030 % + 10 mV 1 kHz 至 5 kHz 500 V 至 1100 V CMC 0,025 % + 10 mV 5 kHz 至 10 kHz 500 V 至 1100 V CMC 0,030 % + 10 mV 10 kHz 至 30 kHz 500 V 至 1100 V CMC 0,037 % + 50 mV MK4, MK8, MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3103998ee0cc44fc7dc9adb4","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / woltomierze wysokonapięciowe, sondy, źródła i testery","test_object_en":"AC voltage / High-voltage voltmeters, probes, sources and testers","test_object_zh":"交流电压 / 高压电压表、探头、电源和测试仪","test_object_cs":"Střídavé napětí / Vysokonapěťové voltmetry, sondy, zdroje a testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 1,1 kV do 15 kV","cmc":"0,10 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"1,1 kV to 15 kV","cmc":"0,10 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"1,1 kV 至 15 kV","cmc":"0,10 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"1,1 kV až 15 kV","cmc":"0,10 %"}],"technique":"Multimetr wzorcowy z transformatorem WN: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter with an HV transformer: comparison or direct measurement","technique_zh":"带高压互感器的标准万用表：比较或直接测量","technique_cs":"Etalonový multimetr s vn transformátorem: porovnání nebo přímé měření","techniques":["Multimetr wzorcowy z transformatorem WN: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter with an HV transformer: comparison or direct measurement"],"techniques_zh":["带高压互感器的标准万用表：比较或直接测量"],"techniques_cs":["Etalonový multimetr s vn transformátorem: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n45 Hz do 65 Hz od 1,1 kV do 15 kV CMC 0,10 %\nMultimetr wzorcowy z transformatorem WN: porównanie lub pomiar bezpośredni","reference":"MK10","norm_bases":["MK10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / woltomierze wysokonapięciowe, sondy, źródła i testery Wzorcowanie – wielkości elektryczne Multimetr wzorcowy z transformatorem WN: porównanie lub pomiar bezpośredni 45 Hz do 65 Hz od 1,1 kV do 15 kV CMC 0,10 % Střídavé napětí / Vysokonapěťové voltmetry, sondy, zdroje a testery Kalibrace – elektrické veličiny Etalonový multimetr s vn transformátorem: porovnání nebo přímé měření 45 Hz až 65 Hz 1,1 kV až 15 kV CMC 0,10 % MK10 Napiecie przemienne / woltomierze wysokonapieciowe, sondy, zrodla i testery Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy z transformatorem WN: porownanie lub pomiar bezposredni 45 Hz do 65 Hz od 1,1 kV do 15 kV CMC 0,10 % Stridave napeti / Vysokonapetove voltmetry, sondy, zdroje a testery Kalibrace – elektricke veliciny Etalonovy multimetr s vn transformatorem: porovnani nebo prime mereni 45 Hz az 65 Hz 1,1 kV az 15 kV CMC 0,10 % MK10","search_en":"AC voltage / High-voltage voltmeters, probes, sources and testers Calibration – electrical quantities Standard multimeter with an HV transformer: comparison or direct measurement 45 Hz to 65 Hz 1,1 kV to 15 kV CMC 0,10 % MK10","search_zh":"交流电压 / 高压电压表、探头、电源和测试仪 校准 – 电学量 带高压互感器的标准万用表：比较或直接测量 45 Hz 至 65 Hz 1,1 kV 至 15 kV CMC 0,10 % MK10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"954cfdde6258ab1a4b1ff02a","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / woltomierze wysokonapięciowe, sondy, źródła i testery","test_object_en":"AC voltage / High-voltage voltmeters, probes, sources and testers","test_object_zh":"交流电压 / 高压电压表、探头、电源和测试仪","test_object_cs":"Střídavé napětí / Vysokonapěťové voltmetry, sondy, zdroje a testery","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 15 kV do 30 kV","cmc":"0,50 %"},{"name":"45 Hz do 65 Hz","range":"od 30 kV do 100 kV","cmc":"0,80 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"15 kV to 30 kV","cmc":"0,50 %"},{"name":"45 Hz to 65 Hz","range":"30 kV to 100 kV","cmc":"0,80 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"15 kV 至 30 kV","cmc":"0,50 %"},{"name":"45 Hz 至 65 Hz","range":"30 kV 至 100 kV","cmc":"0,80 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"15 kV až 30 kV","cmc":"0,50 %"},{"name":"45 Hz až 65 Hz","range":"30 kV až 100 kV","cmc":"0,80 %"}],"technique":"Woltomierz wzorcowy WN: porównanie lub pomiar bezpośredni","technique_en":"Standard HV voltmeter: comparison or direct measurement","technique_zh":"标准高压电压表：比较或直接测量","technique_cs":"Etalonový vn voltmetr: porovnání nebo přímé měření","techniques":["Woltomierz wzorcowy WN: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard HV voltmeter: comparison or direct measurement"],"techniques_zh":["标准高压电压表：比较或直接测量"],"techniques_cs":["Etalonový vn voltmetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 65 Hz od 15 kV do 30 kV CMC 0,50 %\n45 Hz do 65 Hz od 30 kV do 100 kV CMC 0,80 %\nWoltomierz wzorcowy WN: porównanie lub pomiar bezpośredni","reference":"MK10","norm_bases":["MK10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / woltomierze wysokonapięciowe, sondy, źródła i testery Wzorcowanie – wielkości elektryczne Woltomierz wzorcowy WN: porównanie lub pomiar bezpośredni 45 Hz do 65 Hz od 15 kV do 30 kV CMC 0,50 % 45 Hz do 65 Hz od 30 kV do 100 kV CMC 0,80 % Střídavé napětí / Vysokonapěťové voltmetry, sondy, zdroje a testery Kalibrace – elektrické veličiny Etalonový vn voltmetr: porovnání nebo přímé měření 45 Hz až 65 Hz 15 kV až 30 kV CMC 0,50 % 45 Hz až 65 Hz 30 kV až 100 kV CMC 0,80 % MK10 Napiecie przemienne / woltomierze wysokonapieciowe, sondy, zrodla i testery Wzorcowanie – wielkosci elektryczne Woltomierz wzorcowy WN: porownanie lub pomiar bezposredni 45 Hz do 65 Hz od 15 kV do 30 kV CMC 0,50 % 45 Hz do 65 Hz od 30 kV do 100 kV CMC 0,80 % Stridave napeti / Vysokonapetove voltmetry, sondy, zdroje a testery Kalibrace – elektricke veliciny Etalonovy vn voltmetr: porovnani nebo prime mereni 45 Hz az 65 Hz 15 kV az 30 kV CMC 0,50 % 45 Hz az 65 Hz 30 kV az 100 kV CMC 0,80 % MK10","search_en":"AC voltage / High-voltage voltmeters, probes, sources and testers Calibration – electrical quantities Standard HV voltmeter: comparison or direct measurement 45 Hz to 65 Hz 15 kV to 30 kV CMC 0,50 % 45 Hz to 65 Hz 30 kV to 100 kV CMC 0,80 % MK10","search_zh":"交流电压 / 高压电压表、探头、电源和测试仪 校准 – 电学量 标准高压电压表：比较或直接测量 45 Hz 至 65 Hz 15 kV 至 30 kV CMC 0,50 % 45 Hz 至 65 Hz 30 kV 至 100 kV CMC 0,80 % MK10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d93e17a647535bb1bf39d3c6","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"3","test_object":"Składowe harmoniczne napięcia / analizatory sieci zasilającej, mierniki do badań instalacji, źródła zasilania przemiennego / harmoniczna podstawowa: 45 Hz do 65 Hz","test_object_en":"Voltage harmonic components / Power network analysers, installation testers, AC power sources / Fundamental: 45 Hz to 65 Hz","test_object_zh":"电压谐波分量 / 电网分析仪、电气安装测试仪、交流电源 / 基波：45 Hz 至 65 Hz","test_object_cs":"Harmonické složky Napětí / Analyzátory napájecí sítě, revizní přístroje, střídavé napájecí zdroje / Základní harmonická: 45 Hz až 65 Hz","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"napięcie złożone 3,3 V do 33 V; częstotliwość harmonicznej 45 Hz do 5 kHz","range":"od 3,3 mV do 33 V","cmc":"0,10 % + 4 mV"},{"name":"napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 45 Hz do 440 Hz","range":"od 33 mV do 330 V","cmc":"0,20 % + 20 mV"},{"name":"napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 440 Hz do 660 Hz","range":"od 33 mV do 99 V","cmc":"0,25 % + 20 mV"},{"name":"napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 660 Hz do 1,2 kHz","range":"od 33 mV do 33 V","cmc":"0,35 % + 25 mV"},{"name":"napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 1,2 kHz do 2,0 kHz","range":"od 33 mV do 16,5 V","cmc":"0,50 % + 40 mV"},{"name":"napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 45 Hz do 440 Hz","range":"od 330 mV do 720 V","cmc":"0,25 % + 0,10 V"},{"name":"napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 440 Hz do 660 Hz","range":"od 330 mV do 216 V","cmc":"0,25 % + 0,10 V"},{"name":"napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 660 Hz do 1,2 kHz","range":"od 330 mV do 72 V","cmc":"0,40 % + 0,10 V"},{"name":"napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 1,2 kHz do 2,0 kHz","range":"od 330 mV do 36 V","cmc":"0,60 % + 0,16 V"}],"parameters_en":[{"name":"composite voltage 3,3 V to 33 V; harmonic frequency 45 Hz to 5 kHz","range":"3,3 mV to 33 V","cmc":"0,10 % + 4 mV"},{"name":"composite voltage 33 V to 330 V; harmonic frequency 45 Hz to 440 Hz","range":"33 mV to 330 V","cmc":"0,20 % + 20 mV"},{"name":"composite voltage 33 V to 330 V; harmonic frequency 440 Hz to 660 Hz","range":"33 mV to 99 V","cmc":"0,25 % + 20 mV"},{"name":"composite voltage 33 V to 330 V; harmonic frequency 660 Hz to 1,2 kHz","range":"33 mV to 33 V","cmc":"0,35 % + 25 mV"},{"name":"composite voltage 33 V to 330 V; harmonic frequency 1,2 kHz to 2,0 kHz","range":"33 mV to 16,5 V","cmc":"0,50 % + 40 mV"},{"name":"composite voltage 330 V to 720 V; harmonic frequency 45 Hz to 440 Hz","range":"330 mV to 720 V","cmc":"0,25 % + 0,10 V"},{"name":"composite voltage 330 V to 720 V; harmonic frequency 440 Hz to 660 Hz","range":"330 mV to 216 V","cmc":"0,25 % + 0,10 V"},{"name":"composite voltage 330 V to 720 V; harmonic frequency 660 Hz to 1,2 kHz","range":"330 mV to 72 V","cmc":"0,40 % + 0,10 V"},{"name":"composite voltage 330 V to 720 V; harmonic frequency 1,2 kHz to 2,0 kHz","range":"330 mV to 36 V","cmc":"0,60 % + 0,16 V"}],"parameters_zh":[{"name":"合成电压 3,3 V 至 33 V；谐波频率 45 Hz 至 5 kHz","range":"3,3 mV 至 33 V","cmc":"0,10 % + 4 mV"},{"name":"合成电压 33 V 至 330 V；谐波频率 45 Hz 至 440 Hz","range":"33 mV 至 330 V","cmc":"0,20 % + 20 mV"},{"name":"合成电压 33 V 至 330 V；谐波频率 440 Hz 至 660 Hz","range":"33 mV 至 99 V","cmc":"0,25 % + 20 mV"},{"name":"合成电压 33 V 至 330 V；谐波频率 660 Hz 至 1,2 kHz","range":"33 mV 至 33 V","cmc":"0,35 % + 25 mV"},{"name":"合成电压 33 V 至 330 V；谐波频率 1,2 kHz 至 2,0 kHz","range":"33 mV 至 16,5 V","cmc":"0,50 % + 40 mV"},{"name":"合成电压 330 V 至 720 V；谐波频率 45 Hz 至 440 Hz","range":"330 mV 至 720 V","cmc":"0,25 % + 0,10 V"},{"name":"合成电压 330 V 至 720 V；谐波频率 440 Hz 至 660 Hz","range":"330 mV 至 216 V","cmc":"0,25 % + 0,10 V"},{"name":"合成电压 330 V 至 720 V；谐波频率 660 Hz 至 1,2 kHz","range":"330 mV 至 72 V","cmc":"0,40 % + 0,10 V"},{"name":"合成电压 330 V 至 720 V；谐波频率 1,2 kHz 至 2,0 kHz","range":"330 mV 至 36 V","cmc":"0,60 % + 0,16 V"}],"parameters_cs":[{"name":"složené napětí 3,3 V až 33 V; frekvence harmonické 45 Hz až 5 kHz","range":"3,3 mV až 33 V","cmc":"0,10 % + 4 mV"},{"name":"složené napětí 33 V až 330 V; frekvence harmonické 45 Hz až 440 Hz","range":"33 mV až 330 V","cmc":"0,20 % + 20 mV"},{"name":"složené napětí 33 V až 330 V; frekvence harmonické 440 Hz až 660 Hz","range":"33 mV až 99 V","cmc":"0,25 % + 20 mV"},{"name":"složené napětí 33 V až 330 V; frekvence harmonické 660 Hz až 1,2 kHz","range":"33 mV až 33 V","cmc":"0,35 % + 25 mV"},{"name":"složené napětí 33 V až 330 V; frekvence harmonické 1,2 kHz až 2,0 kHz","range":"33 mV až 16,5 V","cmc":"0,50 % + 40 mV"},{"name":"složené napětí 330 V až 720 V; frekvence harmonické 45 Hz až 440 Hz","range":"330 mV až 720 V","cmc":"0,25 % + 0,10 V"},{"name":"složené napětí 330 V až 720 V; frekvence harmonické 440 Hz až 660 Hz","range":"330 mV až 216 V","cmc":"0,25 % + 0,10 V"},{"name":"složené napětí 330 V až 720 V; frekvence harmonické 660 Hz až 1,2 kHz","range":"330 mV až 72 V","cmc":"0,40 % + 0,10 V"},{"name":"složené napětí 330 V až 720 V; frekvence harmonické 1,2 kHz až 2,0 kHz","range":"330 mV až 36 V","cmc":"0,60 % + 0,16 V"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym","technique_en":"Direct generation by a standard calibrator or direct measurement by a standard analyser","technique_zh":"用标准校准器直接产生或用标准分析仪直接测量","technique_cs":"Přímé generování etalonovým kalibrátorem nebo přímé měření etalonovým analyzátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym"],"techniques_en":["Direct generation by a standard calibrator or direct measurement by a standard analyser"],"techniques_zh":["用标准校准器直接产生或用标准分析仪直接测量"],"techniques_cs":["Přímé generování etalonovým kalibrátorem nebo přímé měření etalonovým analyzátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nnapięcie złożone 3,3 V do 33 V; częstotliwość harmonicznej 45 Hz do 5 kHz od 3,3 mV do 33 V CMC 0,10 % + 4 mV\nnapięcie złożone 33 V do 330 V; częstotliwość harmonicznej 45 Hz do 440 Hz od 33 mV do 330 V CMC 0,20 % + 20 mV\nnapięcie złożone 33 V do 330 V; częstotliwość harmonicznej 440 Hz do 660 Hz od 33 mV do 99 V CMC 0,25 % + 20 mV\nnapięcie złożone 33 V do 330 V; częstotliwość harmonicznej 660 Hz do 1,2 kHz od 33 mV do 33 V CMC 0,35 % + 25 mV\nnapięcie złożone 33 V do 330 V; częstotliwość harmonicznej 1,2 kHz do 2,0 kHz od 33 mV do 16,5 V CMC 0,50 % + 40 mV\nnapięcie złożone 330 V do 720 V; częstotliwość harmonicznej 45 Hz do 440 Hz od 330 mV do 720 V CMC 0,25 % + 0,10 V\nnapięcie złożone 330 V do 720 V; częstotliwość harmonicznej 440 Hz do 660 Hz od 330 mV do 216 V CMC 0,25 % + 0,10 V\nnapięcie złożone 330 V do 720 V; częstotliwość harmonicznej 660 Hz do 1,2 kHz od 330 mV do 72 V CMC 0,40 % + 0,10 V\nnapięcie złożone 330 V do 720 V; częstotliwość harmonicznej 1,2 kHz do 2,0 kHz od 330 mV do 36 V CMC 0,60 % + 0,16 V\nBezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym","reference":"MK9, MK11","norm_bases":["MK9","MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":"Względna składowa niepewności pomiaru odnosi się do harmonicznej podstawowej.","note_en":"The relative component of the measurement uncertainty refers to the fundamental harmonic.","note_zh":"测量不确定度的相对分量以基波为基准。","note_cs":"Relativní složka nejistoty měření je vztažena k základní harmonické.","search_text":"Składowe harmoniczne napięcia / analizatory sieci zasilającej, mierniki do badań instalacji, źródła zasilania przemiennego / harmoniczna podstawowa: 45 Hz do 65 Hz Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym napięcie złożone 3,3 V do 33 V; częstotliwość harmonicznej 45 Hz do 5 kHz od 3,3 mV do 33 V CMC 0,10 % + 4 mV napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 45 Hz do 440 Hz od 33 mV do 330 V CMC 0,20 % + 20 mV napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 440 Hz do 660 Hz od 33 mV do 99 V CMC 0,25 % + 20 mV napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 660 Hz do 1,2 kHz od 33 mV do 33 V CMC 0,35 % + 25 mV napięcie złożone 33 V do 330 V; częstotliwość harmonicznej 1,2 kHz do 2,0 kHz od 33 mV do 16,5 V CMC 0,50 % + 40 mV napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 45 Hz do 440 Hz od 330 mV do 720 V CMC 0,25 % + 0,10 V napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 440 Hz do 660 Hz od 330 mV do 216 V CMC 0,25 % + 0,10 V napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 660 Hz do 1,2 kHz od 330 mV do 72 V CMC 0,40 % + 0,10 V napięcie złożone 330 V do 720 V; częstotliwość harmonicznej 1,2 kHz do 2,0 kHz od 330 mV do 36 V CMC 0,60 % + 0,16 V Harmonické složky Napětí / Analyzátory napájecí sítě, revizní přístroje, střídavé napájecí zdroje / Základní harmonická: 45 Hz až 65 Hz Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem nebo přímé měření etalonovým analyzátorem složené napětí 3,3 V až 33 V; frekvence harmonické 45 Hz až 5 kHz 3,3 mV až 33 V CMC 0,10 % + 4 mV složené napětí 33 V až 330 V; frekvence harmonické 45 Hz až 440 Hz 33 mV až 330 V CMC 0,20 % + 20 mV složené napětí 33 V až 330 V; frekvence harmonické 440 Hz až 660 Hz 33 mV až 99 V CMC 0,25 % + 20 mV složené napětí 33 V až 330 V; frekvence harmonické 660 Hz až 1,2 kHz 33 mV až 33 V CMC 0,35 % + 25 mV složené napětí 33 V až 330 V; frekvence harmonické 1,2 kHz až 2,0 kHz 33 mV až 16,5 V CMC 0,50 % + 40 mV složené napětí 330 V až 720 V; frekvence harmonické 45 Hz až 440 Hz 330 mV až 720 V CMC 0,25 % + 0,10 V složené napětí 330 V až 720 V; frekvence harmonické 440 Hz až 660 Hz 330 mV až 216 V CMC 0,25 % + 0,10 V složené napětí 330 V až 720 V; frekvence harmonické 660 Hz až 1,2 kHz 330 mV až 72 V CMC 0,40 % + 0,10 V složené napětí 330 V až 720 V; frekvence harmonické 1,2 kHz až 2,0 kHz 330 mV až 36 V CMC 0,60 % + 0,16 V MK9, MK11 Skladowe harmoniczne napiecia / analizatory sieci zasilajacej, mierniki do badan instalacji, zrodla zasilania przemiennego / harmoniczna podstawowa: 45 Hz do 65 Hz Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym lub pomiar bezposredni analizatorem wzorcowym napiecie zlozone 3,3 V do 33 V; czestotliwosc harmonicznej 45 Hz do 5 kHz od 3,3 mV do 33 V CMC 0,10 % + 4 mV napiecie zlozone 33 V do 330 V; czestotliwosc harmonicznej 45 Hz do 440 Hz od 33 mV do 330 V CMC 0,20 % + 20 mV napiecie zlozone 33 V do 330 V; czestotliwosc harmonicznej 440 Hz do 660 Hz od 33 mV do 99 V CMC 0,25 % + 20 mV napiecie zlozone 33 V do 330 V; czestotliwosc harmonicznej 660 Hz do 1,2 kHz od 33 mV do 33 V CMC 0,35 % + 25 mV napiecie zlozone 33 V do 330 V; czestotliwosc harmonicznej 1,2 kHz do 2,0 kHz od 33 mV do 16,5 V CMC 0,50 % + 40 mV napiecie zlozone 330 V do 720 V; czestotliwosc harmonicznej 45 Hz do 440 Hz od 330 mV do 720 V CMC 0,25 % + 0,10 V napiecie zlozone 330 V do 720 V; czestotliwosc harmonicznej 440 Hz do 660 Hz od 330 mV do 216 V CMC 0,25 % + 0,10 V napiecie zlozone 330 V do 720 V; czestotliwosc harmonicznej 660 Hz do 1,2 kHz od 330 mV do 72 V CMC 0,40 % + 0,10 V napiecie zlozone 330 V do 720 V; czestotliwosc harmonicznej 1,2 kHz do 2,0 kHz od 330 mV do 36 V CMC 0,60 % + 0,16 V Harmonicke slozky Napeti / Analyzatory napajeci site, revizni pristroje, stridave napajeci zdroje / Zakladni harmonicka: 45 Hz az 65 Hz Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem nebo prime mereni etalonovym analyzatorem slozene napeti 3,3 V az 33 V; frekvence harmonicke 45 Hz az 5 kHz 3,3 mV az 33 V CMC 0,10 % + 4 mV slozene napeti 33 V az 330 V; frekvence harmonicke 45 Hz az 440 Hz 33 mV az 330 V CMC 0,20 % + 20 mV slozene napeti 33 V az 330 V; frekvence harmonicke 440 Hz az 660 Hz 33 mV az 99 V CMC 0,25 % + 20 mV slozene napeti 33 V az 330 V; frekvence harmonicke 660 Hz az 1,2 kHz 33 mV az 33 V CMC 0,35 % + 25 mV slozene napeti 33 V az 330 V; frekvence harmonicke 1,2 kHz az 2,0 kHz 33 mV az 16,5 V CMC 0,50 % + 40 mV slozene napeti 330 V az 720 V; frekvence harmonicke 45 Hz az 440 Hz 330 mV az 720 V CMC 0,25 % + 0,10 V slozene napeti 330 V az 720 V; frekvence harmonicke 440 Hz az 660 Hz 330 mV az 216 V CMC 0,25 % + 0,10 V slozene napeti 330 V az 720 V; frekvence harmonicke 660 Hz az 1,2 kHz 330 mV az 72 V CMC 0,40 % + 0,10 V slozene napeti 330 V az 720 V; frekvence harmonicke 1,2 kHz az 2,0 kHz 330 mV az 36 V CMC 0,60 % + 0,16 V MK9, MK11","search_en":"Voltage harmonic components / Power network analysers, installation testers, AC power sources / Fundamental: 45 Hz to 65 Hz Calibration – electrical quantities Direct generation by a standard calibrator or direct measurement by a standard analyser composite voltage 3,3 V to 33 V; harmonic frequency 45 Hz to 5 kHz 3,3 mV to 33 V CMC 0,10 % + 4 mV composite voltage 33 V to 330 V; harmonic frequency 45 Hz to 440 Hz 33 mV to 330 V CMC 0,20 % + 20 mV composite voltage 33 V to 330 V; harmonic frequency 440 Hz to 660 Hz 33 mV to 99 V CMC 0,25 % + 20 mV composite voltage 33 V to 330 V; harmonic frequency 660 Hz to 1,2 kHz 33 mV to 33 V CMC 0,35 % + 25 mV composite voltage 33 V to 330 V; harmonic frequency 1,2 kHz to 2,0 kHz 33 mV to 16,5 V CMC 0,50 % + 40 mV composite voltage 330 V to 720 V; harmonic frequency 45 Hz to 440 Hz 330 mV to 720 V CMC 0,25 % + 0,10 V composite voltage 330 V to 720 V; harmonic frequency 440 Hz to 660 Hz 330 mV to 216 V CMC 0,25 % + 0,10 V composite voltage 330 V to 720 V; harmonic frequency 660 Hz to 1,2 kHz 330 mV to 72 V CMC 0,40 % + 0,10 V composite voltage 330 V to 720 V; harmonic frequency 1,2 kHz to 2,0 kHz 330 mV to 36 V CMC 0,60 % + 0,16 V MK9, MK11","search_zh":"电压谐波分量 / 电网分析仪、电气安装测试仪、交流电源 / 基波：45 Hz 至 65 Hz 校准 – 电学量 用标准校准器直接产生或用标准分析仪直接测量 合成电压 3,3 V 至 33 V；谐波频率 45 Hz 至 5 kHz 3,3 mV 至 33 V CMC 0,10 % + 4 mV 合成电压 33 V 至 330 V；谐波频率 45 Hz 至 440 Hz 33 mV 至 330 V CMC 0,20 % + 20 mV 合成电压 33 V 至 330 V；谐波频率 440 Hz 至 660 Hz 33 mV 至 99 V CMC 0,25 % + 20 mV 合成电压 33 V 至 330 V；谐波频率 660 Hz 至 1,2 kHz 33 mV 至 33 V CMC 0,35 % + 25 mV 合成电压 33 V 至 330 V；谐波频率 1,2 kHz 至 2,0 kHz 33 mV 至 16,5 V CMC 0,50 % + 40 mV 合成电压 330 V 至 720 V；谐波频率 45 Hz 至 440 Hz 330 mV 至 720 V CMC 0,25 % + 0,10 V 合成电压 330 V 至 720 V；谐波频率 440 Hz 至 660 Hz 330 mV 至 216 V CMC 0,25 % + 0,10 V 合成电压 330 V 至 720 V；谐波频率 660 Hz 至 1,2 kHz 330 mV 至 72 V CMC 0,40 % + 0,10 V 合成电压 330 V 至 720 V；谐波频率 1,2 kHz 至 2,0 kHz 330 mV 至 36 V CMC 0,60 % + 0,16 V MK9, MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fcfe69ff156bdfa9a33a5f6","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Napięcie w.cz. / oscyloskopy, sondy napięciowe","test_object_en":"RF voltage / Oscilloscopes, voltage probes","test_object_zh":"射频电压 / 示波器、电压探头","test_object_cs":"Vf napětí / Osciloskopy, napěťové sondy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz do 100 MHz","range":"od 2,0 mV do 0,50 V","cmc":"1,5 % + 35 µV"},{"name":"100 MHz do 300 MHz","range":"od 2,0 mV do 0,50 V","cmc":"2,0 % + 35 µV"},{"name":"1 kHz do 100 MHz","range":"od 0,50 V do 1,0 V","cmc":"1,5 %"},{"name":"100 MHz do 300 MHz","range":"od 0,50 V do 1,0 V","cmc":"2,0 %"},{"name":"1 kHz do 100 MHz","range":"od 1,0 V do 2,0 V","cmc":"1,5 %"},{"name":"100 MHz do 250 MHz","range":"od 1,0 V do 2,0 V","cmc":"2,0 %"},{"name":"1 kHz do 50 MHz","range":"od 2,0 V do 3,5 V","cmc":"1,5 %"}],"parameters_en":[{"name":"1 kHz to 100 MHz","range":"2,0 mV to 0,50 V","cmc":"1,5 % + 35 µV"},{"name":"100 MHz to 300 MHz","range":"2,0 mV to 0,50 V","cmc":"2,0 % + 35 µV"},{"name":"1 kHz to 100 MHz","range":"0,50 V to 1,0 V","cmc":"1,5 %"},{"name":"100 MHz to 300 MHz","range":"0,50 V to 1,0 V","cmc":"2,0 %"},{"name":"1 kHz to 100 MHz","range":"1,0 V to 2,0 V","cmc":"1,5 %"},{"name":"100 MHz to 250 MHz","range":"1,0 V to 2,0 V","cmc":"2,0 %"},{"name":"1 kHz to 50 MHz","range":"2,0 V to 3,5 V","cmc":"1,5 %"}],"parameters_zh":[{"name":"1 kHz 至 100 MHz","range":"2,0 mV 至 0,50 V","cmc":"1,5 % + 35 µV"},{"name":"100 MHz 至 300 MHz","range":"2,0 mV 至 0,50 V","cmc":"2,0 % + 35 µV"},{"name":"1 kHz 至 100 MHz","range":"0,50 V 至 1,0 V","cmc":"1,5 %"},{"name":"100 MHz 至 300 MHz","range":"0,50 V 至 1,0 V","cmc":"2,0 %"},{"name":"1 kHz 至 100 MHz","range":"1,0 V 至 2,0 V","cmc":"1,5 %"},{"name":"100 MHz 至 250 MHz","range":"1,0 V 至 2,0 V","cmc":"2,0 %"},{"name":"1 kHz 至 50 MHz","range":"2,0 V 至 3,5 V","cmc":"1,5 %"}],"parameters_cs":[{"name":"1 kHz až 100 MHz","range":"2,0 mV až 0,50 V","cmc":"1,5 % + 35 µV"},{"name":"100 MHz až 300 MHz","range":"2,0 mV až 0,50 V","cmc":"2,0 % + 35 µV"},{"name":"1 kHz až 100 MHz","range":"0,50 V až 1,0 V","cmc":"1,5 %"},{"name":"100 MHz až 300 MHz","range":"0,50 V až 1,0 V","cmc":"2,0 %"},{"name":"1 kHz až 100 MHz","range":"1,0 V až 2,0 V","cmc":"1,5 %"},{"name":"100 MHz až 250 MHz","range":"1,0 V až 2,0 V","cmc":"2,0 %"},{"name":"1 kHz až 50 MHz","range":"2,0 V až 3,5 V","cmc":"1,5 %"}],"technique":"Generowanie wzorcowym kalibratorem oscyloskopów","technique_en":"Generation by a standard oscilloscope calibrator","technique_zh":"用标准示波器校准器产生","technique_cs":"Generování etalonovým kalibrátorem osciloskopů","techniques":["Generowanie wzorcowym kalibratorem oscyloskopów"],"techniques_en":["Generation by a standard oscilloscope calibrator"],"techniques_zh":["用标准示波器校准器产生"],"techniques_cs":["Generování etalonovým kalibrátorem osciloskopů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz do 100 MHz od 2,0 mV do 0,50 V CMC 1,5 % + 35 µV\n100 MHz do 300 MHz od 2,0 mV do 0,50 V CMC 2,0 % + 35 µV\n1 kHz do 100 MHz od 0,50 V do 1,0 V CMC 1,5 %\n100 MHz do 300 MHz od 0,50 V do 1,0 V CMC 2,0 %\n1 kHz do 100 MHz od 1,0 V do 2,0 V CMC 1,5 %\n100 MHz do 250 MHz od 1,0 V do 2,0 V CMC 2,0 %\n1 kHz do 50 MHz od 2,0 V do 3,5 V CMC 1,5 %\nGenerowanie wzorcowym kalibratorem oscyloskopów","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie w.cz. / oscyloskopy, sondy napięciowe Wzorcowanie – wielkości elektryczne Generowanie wzorcowym kalibratorem oscyloskopów 1 kHz do 100 MHz od 2,0 mV do 0,50 V CMC 1,5 % + 35 µV 100 MHz do 300 MHz od 2,0 mV do 0,50 V CMC 2,0 % + 35 µV 1 kHz do 100 MHz od 0,50 V do 1,0 V CMC 1,5 % 100 MHz do 300 MHz od 0,50 V do 1,0 V CMC 2,0 % 1 kHz do 100 MHz od 1,0 V do 2,0 V CMC 1,5 % 100 MHz do 250 MHz od 1,0 V do 2,0 V CMC 2,0 % 1 kHz do 50 MHz od 2,0 V do 3,5 V CMC 1,5 % Vf napětí / Osciloskopy, napěťové sondy Kalibrace – elektrické veličiny Generování etalonovým kalibrátorem osciloskopů 1 kHz až 100 MHz 2,0 mV až 0,50 V CMC 1,5 % + 35 µV 100 MHz až 300 MHz 2,0 mV až 0,50 V CMC 2,0 % + 35 µV 1 kHz až 100 MHz 0,50 V až 1,0 V CMC 1,5 % 100 MHz až 300 MHz 0,50 V až 1,0 V CMC 2,0 % 1 kHz až 100 MHz 1,0 V až 2,0 V CMC 1,5 % 100 MHz až 250 MHz 1,0 V až 2,0 V CMC 2,0 % 1 kHz až 50 MHz 2,0 V až 3,5 V CMC 1,5 % MK16 Napiecie w.cz. / oscyloskopy, sondy napieciowe Wzorcowanie – wielkosci elektryczne Generowanie wzorcowym kalibratorem oscyloskopow 1 kHz do 100 MHz od 2,0 mV do 0,50 V CMC 1,5 % + 35 µV 100 MHz do 300 MHz od 2,0 mV do 0,50 V CMC 2,0 % + 35 µV 1 kHz do 100 MHz od 0,50 V do 1,0 V CMC 1,5 % 100 MHz do 300 MHz od 0,50 V do 1,0 V CMC 2,0 % 1 kHz do 100 MHz od 1,0 V do 2,0 V CMC 1,5 % 100 MHz do 250 MHz od 1,0 V do 2,0 V CMC 2,0 % 1 kHz do 50 MHz od 2,0 V do 3,5 V CMC 1,5 % Vf napeti / Osciloskopy, napetove sondy Kalibrace – elektricke veliciny Generovani etalonovym kalibratorem osciloskopu 1 kHz az 100 MHz 2,0 mV az 0,50 V CMC 1,5 % + 35 µV 100 MHz az 300 MHz 2,0 mV az 0,50 V CMC 2,0 % + 35 µV 1 kHz az 100 MHz 0,50 V az 1,0 V CMC 1,5 % 100 MHz az 300 MHz 0,50 V az 1,0 V CMC 2,0 % 1 kHz az 100 MHz 1,0 V az 2,0 V CMC 1,5 % 100 MHz az 250 MHz 1,0 V az 2,0 V CMC 2,0 % 1 kHz az 50 MHz 2,0 V az 3,5 V CMC 1,5 % MK16","search_en":"RF voltage / Oscilloscopes, voltage probes Calibration – electrical quantities Generation by a standard oscilloscope calibrator 1 kHz to 100 MHz 2,0 mV to 0,50 V CMC 1,5 % + 35 µV 100 MHz to 300 MHz 2,0 mV to 0,50 V CMC 2,0 % + 35 µV 1 kHz to 100 MHz 0,50 V to 1,0 V CMC 1,5 % 100 MHz to 300 MHz 0,50 V to 1,0 V CMC 2,0 % 1 kHz to 100 MHz 1,0 V to 2,0 V CMC 1,5 % 100 MHz to 250 MHz 1,0 V to 2,0 V CMC 2,0 % 1 kHz to 50 MHz 2,0 V to 3,5 V CMC 1,5 % MK16","search_zh":"射频电压 / 示波器、电压探头 校准 – 电学量 用标准示波器校准器产生 1 kHz 至 100 MHz 2,0 mV 至 0,50 V CMC 1,5 % + 35 µV 100 MHz 至 300 MHz 2,0 mV 至 0,50 V CMC 2,0 % + 35 µV 1 kHz 至 100 MHz 0,50 V 至 1,0 V CMC 1,5 % 100 MHz 至 300 MHz 0,50 V 至 1,0 V CMC 2,0 % 1 kHz 至 100 MHz 1,0 V 至 2,0 V CMC 1,5 % 100 MHz 至 250 MHz 1,0 V 至 2,0 V CMC 2,0 % 1 kHz 至 50 MHz 2,0 V 至 3,5 V CMC 1,5 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf8957b07eea6e3a7ce6bf5b","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Napięcie w.cz. / oscyloskopy, sondy napięciowe","test_object_en":"RF voltage / Oscilloscopes, voltage probes","test_object_zh":"射频电压 / 示波器、电压探头","test_object_cs":"Vf napětí / Osciloskopy, napěťové sondy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"300 MHz do 600 MHz","range":"od 2,0 mV do 0,50 V","cmc":"3,0 % + 35 µV"},{"name":"600 MHz do 900 MHz","range":"od 2,0 mV do 0,50 V","cmc":"6,0 % + 35 µV"},{"name":"900 MHz do 1,2 GHz","range":"od 2,0 mV do 0,50 V","cmc":"12 % + 35 µV"}],"parameters_en":[{"name":"300 MHz to 600 MHz","range":"2,0 mV to 0,50 V","cmc":"3,0 % + 35 µV"},{"name":"600 MHz to 900 MHz","range":"2,0 mV to 0,50 V","cmc":"6,0 % + 35 µV"},{"name":"900 MHz to 1,2 GHz","range":"2,0 mV to 0,50 V","cmc":"12 % + 35 µV"}],"parameters_zh":[{"name":"300 MHz 至 600 MHz","range":"2,0 mV 至 0,50 V","cmc":"3,0 % + 35 µV"},{"name":"600 MHz 至 900 MHz","range":"2,0 mV 至 0,50 V","cmc":"6,0 % + 35 µV"},{"name":"900 MHz 至 1,2 GHz","range":"2,0 mV 至 0,50 V","cmc":"12 % + 35 µV"}],"parameters_cs":[{"name":"300 MHz až 600 MHz","range":"2,0 mV až 0,50 V","cmc":"3,0 % + 35 µV"},{"name":"600 MHz až 900 MHz","range":"2,0 mV až 0,50 V","cmc":"6,0 % + 35 µV"},{"name":"900 MHz až 1,2 GHz","range":"2,0 mV až 0,50 V","cmc":"12 % + 35 µV"}],"technique":"Generowanie z użyciem watomierza wzorcowego i dzielnika mocy","technique_en":"Generation using a standard power meter and a power divider","technique_zh":"使用标准功率计和功率分配器产生","technique_cs":"Generování s užitím etalonového wattmetru a děliče výkonu","techniques":["Generowanie z użyciem watomierza wzorcowego i dzielnika mocy"],"techniques_en":["Generation using a standard power meter and a power divider"],"techniques_zh":["使用标准功率计和功率分配器产生"],"techniques_cs":["Generování s užitím etalonového wattmetru a děliče výkonu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n300 MHz do 600 MHz od 2,0 mV do 0,50 V CMC 3,0 % + 35 µV\n600 MHz do 900 MHz od 2,0 mV do 0,50 V CMC 6,0 % + 35 µV\n900 MHz do 1,2 GHz od 2,0 mV do 0,50 V CMC 12 % + 35 µV\nGenerowanie z użyciem watomierza wzorcowego i dzielnika mocy","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie w.cz. / oscyloskopy, sondy napięciowe Wzorcowanie – wielkości elektryczne Generowanie z użyciem watomierza wzorcowego i dzielnika mocy 300 MHz do 600 MHz od 2,0 mV do 0,50 V CMC 3,0 % + 35 µV 600 MHz do 900 MHz od 2,0 mV do 0,50 V CMC 6,0 % + 35 µV 900 MHz do 1,2 GHz od 2,0 mV do 0,50 V CMC 12 % + 35 µV Vf napětí / Osciloskopy, napěťové sondy Kalibrace – elektrické veličiny Generování s užitím etalonového wattmetru a děliče výkonu 300 MHz až 600 MHz 2,0 mV až 0,50 V CMC 3,0 % + 35 µV 600 MHz až 900 MHz 2,0 mV až 0,50 V CMC 6,0 % + 35 µV 900 MHz až 1,2 GHz 2,0 mV až 0,50 V CMC 12 % + 35 µV MK16 Napiecie w.cz. / oscyloskopy, sondy napieciowe Wzorcowanie – wielkosci elektryczne Generowanie z uzyciem watomierza wzorcowego i dzielnika mocy 300 MHz do 600 MHz od 2,0 mV do 0,50 V CMC 3,0 % + 35 µV 600 MHz do 900 MHz od 2,0 mV do 0,50 V CMC 6,0 % + 35 µV 900 MHz do 1,2 GHz od 2,0 mV do 0,50 V CMC 12 % + 35 µV Vf napeti / Osciloskopy, napetove sondy Kalibrace – elektricke veliciny Generovani s uzitim etalonoveho wattmetru a delice vykonu 300 MHz az 600 MHz 2,0 mV az 0,50 V CMC 3,0 % + 35 µV 600 MHz az 900 MHz 2,0 mV az 0,50 V CMC 6,0 % + 35 µV 900 MHz az 1,2 GHz 2,0 mV az 0,50 V CMC 12 % + 35 µV MK16","search_en":"RF voltage / Oscilloscopes, voltage probes Calibration – electrical quantities Generation using a standard power meter and a power divider 300 MHz to 600 MHz 2,0 mV to 0,50 V CMC 3,0 % + 35 µV 600 MHz to 900 MHz 2,0 mV to 0,50 V CMC 6,0 % + 35 µV 900 MHz to 1,2 GHz 2,0 mV to 0,50 V CMC 12 % + 35 µV MK16","search_zh":"射频电压 / 示波器、电压探头 校准 – 电学量 使用标准功率计和功率分配器产生 300 MHz 至 600 MHz 2,0 mV 至 0,50 V CMC 3,0 % + 35 µV 600 MHz 至 900 MHz 2,0 mV 至 0,50 V CMC 6,0 % + 35 µV 900 MHz 至 1,2 GHz 2,0 mV 至 0,50 V CMC 12 % + 35 µV MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44ecd18653a5959f3b374a11","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Napięcie impulsowe / generatory impulsów","test_object_en":"Pulse voltage / Pulse generators","test_object_zh":"脉冲电压 / 脉冲发生器","test_object_cs":"Impulsní napětí / Generátory impulsů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"wartość międzyszczytowa, prostokąt; szerokość > 50 µs","range":"od 1,8 mV do 120 V","cmc":"0,050 % + 20 µV"}],"parameters_en":[{"name":"peak-to-peak value, square wave; width > 50 µs","range":"1,8 mV to 120 V","cmc":"0,050 % + 20 µV"}],"parameters_zh":[{"name":"峰峰值，方波；宽度 > 50 µs","range":"1,8 mV 至 120 V","cmc":"0,050 % + 20 µV"}],"parameters_cs":[{"name":"mezivrcholová hodnota, obdélník; šířka > 50 µs","range":"1,8 mV až 120 V","cmc":"0,050 % + 20 µV"}],"technique":"Pomiar bezpośredni digitizerem wzorcowym","technique_en":"Direct measurement by a standard digitizer","technique_zh":"用标准数字化仪直接测量","technique_cs":"Přímé měření etalonovým digitizérem","techniques":["Pomiar bezpośredni digitizerem wzorcowym"],"techniques_en":["Direct measurement by a standard digitizer"],"techniques_zh":["用标准数字化仪直接测量"],"techniques_cs":["Přímé měření etalonovým digitizérem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nwartość międzyszczytowa, prostokąt; szerokość > 50 µs od 1,8 mV do 120 V CMC 0,050 % + 20 µV\nPomiar bezpośredni digitizerem wzorcowym","reference":"MK9","norm_bases":["MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie impulsowe / generatory impulsów Wzorcowanie – wielkości elektryczne Pomiar bezpośredni digitizerem wzorcowym wartość międzyszczytowa, prostokąt; szerokość > 50 µs od 1,8 mV do 120 V CMC 0,050 % + 20 µV Impulsní napětí / Generátory impulsů Kalibrace – elektrické veličiny Přímé měření etalonovým digitizérem mezivrcholová hodnota, obdélník; šířka > 50 µs 1,8 mV až 120 V CMC 0,050 % + 20 µV MK9 Napiecie impulsowe / generatory impulsow Wzorcowanie – wielkosci elektryczne Pomiar bezposredni digitizerem wzorcowym wartosc miedzyszczytowa, prostokat; szerokosc > 50 µs od 1,8 mV do 120 V CMC 0,050 % + 20 µV Impulsni napeti / Generatory impulsu Kalibrace – elektricke veliciny Prime mereni etalonovym digitizerem mezivrcholova hodnota, obdelnik; sirka > 50 µs 1,8 mV az 120 V CMC 0,050 % + 20 µV MK9","search_en":"Pulse voltage / Pulse generators Calibration – electrical quantities Direct measurement by a standard digitizer peak-to-peak value, square wave; width > 50 µs 1,8 mV to 120 V CMC 0,050 % + 20 µV MK9","search_zh":"脉冲电压 / 脉冲发生器 校准 – 电学量 用标准数字化仪直接测量 峰峰值，方波；宽度 > 50 µs 1,8 mV 至 120 V CMC 0,050 % + 20 µV MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9b8bf4fad789abbfe5c2ca9","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Napięcie impulsowe / oscyloskopy, sondy napięciowe","test_object_en":"Pulse voltage / Oscilloscopes, voltage probes","test_object_zh":"脉冲电压 / 示波器、电压探头","test_object_cs":"Impulsní napětí / Osciloskopy, napěťové sondy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"wartość międzyszczytowa, prostokąt, 50 Ω; szerokość od 50 µs do 50 ms","range":"od 1,8 mV do 2,2 V","cmc":"0,25 % + 0,1 mV"},{"name":"wartość międzyszczytowa, prostokąt; szerokość od 50 µs do 50 ms","range":"od 1,8 mV do 55 V","cmc":"0,25 % + 0,1 mV"},{"name":"wartość międzyszczytowa, prostokąt; szerokość od 500 µs do 5 ms","range":"od 95 V do 105 V","cmc":"0,25 %"}],"parameters_en":[{"name":"peak-to-peak value, square wave, 50 Ω; width 50 µs to 50 ms","range":"1,8 mV to 2,2 V","cmc":"0,25 % + 0,1 mV"},{"name":"peak-to-peak value, square wave; width 50 µs to 50 ms","range":"1,8 mV to 55 V","cmc":"0,25 % + 0,1 mV"},{"name":"peak-to-peak value, square wave; width 500 µs to 5 ms","range":"95 V to 105 V","cmc":"0,25 %"}],"parameters_zh":[{"name":"峰峰值，方波，50 Ω；宽度 50 µs 至 50 ms","range":"1,8 mV 至 2,2 V","cmc":"0,25 % + 0,1 mV"},{"name":"峰峰值，方波；宽度 50 µs 至 50 ms","range":"1,8 mV 至 55 V","cmc":"0,25 % + 0,1 mV"},{"name":"峰峰值，方波；宽度 500 µs 至 5 ms","range":"95 V 至 105 V","cmc":"0,25 %"}],"parameters_cs":[{"name":"mezivrcholová hodnota, obdélník, 50 Ω; šířka 50 µs až 50 ms","range":"1,8 mV až 2,2 V","cmc":"0,25 % + 0,1 mV"},{"name":"mezivrcholová hodnota, obdélník; šířka 50 µs až 50 ms","range":"1,8 mV až 55 V","cmc":"0,25 % + 0,1 mV"},{"name":"mezivrcholová hodnota, obdélník; šířka 500 µs až 5 ms","range":"95 V až 105 V","cmc":"0,25 %"}],"technique":"Bezpośrednie generowanie wzorcowym generatorem impulsów","technique_en":"Direct generation by a standard pulse generator","technique_zh":"用标准脉冲发生器直接产生","technique_cs":"Přímé generování etalonovým impulsním generátorem","techniques":["Bezpośrednie generowanie wzorcowym generatorem impulsów"],"techniques_en":["Direct generation by a standard pulse generator"],"techniques_zh":["用标准脉冲发生器直接产生"],"techniques_cs":["Přímé generování etalonovým impulsním generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nwartość międzyszczytowa, prostokąt, 50 Ω; szerokość od 50 µs do 50 ms od 1,8 mV do 2,2 V CMC 0,25 % + 0,1 mV\nwartość międzyszczytowa, prostokąt; szerokość od 50 µs do 50 ms od 1,8 mV do 55 V CMC 0,25 % + 0,1 mV\nwartość międzyszczytowa, prostokąt; szerokość od 500 µs do 5 ms od 95 V do 105 V CMC 0,25 %\nBezpośrednie generowanie wzorcowym generatorem impulsów","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie impulsowe / oscyloskopy, sondy napięciowe Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie wzorcowym generatorem impulsów wartość międzyszczytowa, prostokąt, 50 Ω; szerokość od 50 µs do 50 ms od 1,8 mV do 2,2 V CMC 0,25 % + 0,1 mV wartość międzyszczytowa, prostokąt; szerokość od 50 µs do 50 ms od 1,8 mV do 55 V CMC 0,25 % + 0,1 mV wartość międzyszczytowa, prostokąt; szerokość od 500 µs do 5 ms od 95 V do 105 V CMC 0,25 % Impulsní napětí / Osciloskopy, napěťové sondy Kalibrace – elektrické veličiny Přímé generování etalonovým impulsním generátorem mezivrcholová hodnota, obdélník, 50 Ω; šířka 50 µs až 50 ms 1,8 mV až 2,2 V CMC 0,25 % + 0,1 mV mezivrcholová hodnota, obdélník; šířka 50 µs až 50 ms 1,8 mV až 55 V CMC 0,25 % + 0,1 mV mezivrcholová hodnota, obdélník; šířka 500 µs až 5 ms 95 V až 105 V CMC 0,25 % MK16 Napiecie impulsowe / oscyloskopy, sondy napieciowe Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie wzorcowym generatorem impulsow wartosc miedzyszczytowa, prostokat, 50 Ω; szerokosc od 50 µs do 50 ms od 1,8 mV do 2,2 V CMC 0,25 % + 0,1 mV wartosc miedzyszczytowa, prostokat; szerokosc od 50 µs do 50 ms od 1,8 mV do 55 V CMC 0,25 % + 0,1 mV wartosc miedzyszczytowa, prostokat; szerokosc od 500 µs do 5 ms od 95 V do 105 V CMC 0,25 % Impulsni napeti / Osciloskopy, napetove sondy Kalibrace – elektricke veliciny Prime generovani etalonovym impulsnim generatorem mezivrcholova hodnota, obdelnik, 50 Ω; sirka 50 µs az 50 ms 1,8 mV az 2,2 V CMC 0,25 % + 0,1 mV mezivrcholova hodnota, obdelnik; sirka 50 µs az 50 ms 1,8 mV az 55 V CMC 0,25 % + 0,1 mV mezivrcholova hodnota, obdelnik; sirka 500 µs az 5 ms 95 V az 105 V CMC 0,25 % MK16","search_en":"Pulse voltage / Oscilloscopes, voltage probes Calibration – electrical quantities Direct generation by a standard pulse generator peak-to-peak value, square wave, 50 Ω; width 50 µs to 50 ms 1,8 mV to 2,2 V CMC 0,25 % + 0,1 mV peak-to-peak value, square wave; width 50 µs to 50 ms 1,8 mV to 55 V CMC 0,25 % + 0,1 mV peak-to-peak value, square wave; width 500 µs to 5 ms 95 V to 105 V CMC 0,25 % MK16","search_zh":"脉冲电压 / 示波器、电压探头 校准 – 电学量 用标准脉冲发生器直接产生 峰峰值，方波，50 Ω；宽度 50 µs 至 50 ms 1,8 mV 至 2,2 V CMC 0,25 % + 0,1 mV 峰峰值，方波；宽度 50 µs 至 50 ms 1,8 mV 至 55 V CMC 0,25 % + 0,1 mV 峰峰值，方波；宽度 500 µs 至 5 ms 95 V 至 105 V CMC 0,25 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ee19c6f831d84df07ada67a0","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Napięcie impulsowe / generatory probiercze","test_object_en":"Pulse voltage / Test generators","test_object_zh":"脉冲电压 / 试验发生器","test_object_cs":"Impulsní napětí / Zkušební generátory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"wartość szczytowa, sinus, półsinus; szerokość > 5 ms","range":"od 1 V do 1 kV","cmc":"0,10 %"}],"parameters_en":[{"name":"peak value, sine, half-sine; width > 5 ms","range":"1 V to 1 kV","cmc":"0,10 %"}],"parameters_zh":[{"name":"峰值，正弦，半正弦；宽度 > 5 ms","range":"1 V 至 1 kV","cmc":"0,10 %"}],"parameters_cs":[{"name":"vrcholová hodnota, sinus, půlsinus; šířka > 5 ms","range":"1 V až 1 kV","cmc":"0,10 %"}],"technique":"Pomiar bezpośredni digitizerem wzorcowym","technique_en":"Direct measurement by a standard digitizer","technique_zh":"用标准数字化仪直接测量","technique_cs":"Přímé měření etalonovým digitizérem","techniques":["Pomiar bezpośredni digitizerem wzorcowym"],"techniques_en":["Direct measurement by a standard digitizer"],"techniques_zh":["用标准数字化仪直接测量"],"techniques_cs":["Přímé měření etalonovým digitizérem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nwartość szczytowa, sinus, półsinus; szerokość > 5 ms od 1 V do 1 kV CMC 0,10 %\nPomiar bezpośredni digitizerem wzorcowym","reference":"MK9","norm_bases":["MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie impulsowe / generatory probiercze Wzorcowanie – wielkości elektryczne Pomiar bezpośredni digitizerem wzorcowym wartość szczytowa, sinus, półsinus; szerokość > 5 ms od 1 V do 1 kV CMC 0,10 % Impulsní napětí / Zkušební generátory Kalibrace – elektrické veličiny Přímé měření etalonovým digitizérem vrcholová hodnota, sinus, půlsinus; šířka > 5 ms 1 V až 1 kV CMC 0,10 % MK9 Napiecie impulsowe / generatory probiercze Wzorcowanie – wielkosci elektryczne Pomiar bezposredni digitizerem wzorcowym wartosc szczytowa, sinus, polsinus; szerokosc > 5 ms od 1 V do 1 kV CMC 0,10 % Impulsni napeti / Zkusebni generatory Kalibrace – elektricke veliciny Prime mereni etalonovym digitizerem vrcholova hodnota, sinus, pulsinus; sirka > 5 ms 1 V az 1 kV CMC 0,10 % MK9","search_en":"Pulse voltage / Test generators Calibration – electrical quantities Direct measurement by a standard digitizer peak value, sine, half-sine; width > 5 ms 1 V to 1 kV CMC 0,10 % MK9","search_zh":"脉冲电压 / 试验发生器 校准 – 电学量 用标准数字化仪直接测量 峰值，正弦，半正弦；宽度 > 5 ms 1 V 至 1 kV CMC 0,10 % MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"203226196ec4c523ba4948c8","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Napięcie impulsowe / generatory probiercze","test_object_en":"Pulse voltage / Test generators","test_object_zh":"脉冲电压 / 试验发生器","test_object_cs":"Impulsní napětí / Zkušební generátory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 kV do 15 kV","cmc":"0,50 %"}],"parameters_en":[{"name":"","range":"1 kV to 15 kV","cmc":"0,50 %"}],"parameters_zh":[{"name":"","range":"1 kV 至 15 kV","cmc":"0,50 %"}],"parameters_cs":[{"name":"","range":"1 kV až 15 kV","cmc":"0,50 %"}],"technique":"Pomiar digitizerem wzorcowym z sondą wysokonapięciową","technique_en":"Measurement by a standard digitizer with a high-voltage probe","technique_zh":"用带高压探头的标准数字化仪测量","technique_cs":"Měření etalonovým digitizérem s vysokonapěťovou sondou","techniques":["Pomiar digitizerem wzorcowym z sondą wysokonapięciową"],"techniques_en":["Measurement by a standard digitizer with a high-voltage probe"],"techniques_zh":["用带高压探头的标准数字化仪测量"],"techniques_cs":["Měření etalonovým digitizérem s vysokonapěťovou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 kV do 15 kV CMC 0,50 %\nPomiar digitizerem wzorcowym z sondą wysokonapięciową","reference":"MK10","norm_bases":["MK10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie impulsowe / generatory probiercze Wzorcowanie – wielkości elektryczne Pomiar digitizerem wzorcowym z sondą wysokonapięciową od 1 kV do 15 kV CMC 0,50 % Impulsní napětí / Zkušební generátory Kalibrace – elektrické veličiny Měření etalonovým digitizérem s vysokonapěťovou sondou 1 kV až 15 kV CMC 0,50 % MK10 Napiecie impulsowe / generatory probiercze Wzorcowanie – wielkosci elektryczne Pomiar digitizerem wzorcowym z sonda wysokonapieciowa od 1 kV do 15 kV CMC 0,50 % Impulsni napeti / Zkusebni generatory Kalibrace – elektricke veliciny Mereni etalonovym digitizerem s vysokonapetovou sondou 1 kV az 15 kV CMC 0,50 % MK10","search_en":"Pulse voltage / Test generators Calibration – electrical quantities Measurement by a standard digitizer with a high-voltage probe 1 kV to 15 kV CMC 0,50 % MK10","search_zh":"脉冲电压 / 试验发生器 校准 – 电学量 用带高压探头的标准数字化仪测量 1 kV 至 15 kV CMC 0,50 % MK10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5a28772f6ed116894e18c1b","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Napięcie impulsowe / generatory EFT / Burst","test_object_en":"Pulse voltage / EFT / Burst generators","test_object_zh":"脉冲电压 / EFT/Burst 发生器","test_object_cs":"Impulsní napětí / Generátory EFT / Burst","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"obciążenie 50 Ω; czas narastania > 4 ns","range":"od 10 V do 4 kV","cmc":"3,0 %"},{"name":"obciążenie 1 kΩ; czas narastania > 4 ns","range":"od 20 V do 8 kV","cmc":"4,0 %"}],"parameters_en":[{"name":"load 50 Ω; rise time > 4 ns","range":"10 V to 4 kV","cmc":"3,0 %"},{"name":"load 1 kΩ; rise time > 4 ns","range":"20 V to 8 kV","cmc":"4,0 %"}],"parameters_zh":[{"name":"负载 50 Ω；上升时间 > 4 ns","range":"10 V 至 4 kV","cmc":"3,0 %"},{"name":"负载 1 kΩ；上升时间 > 4 ns","range":"20 V 至 8 kV","cmc":"4,0 %"}],"parameters_cs":[{"name":"zátěž 50 Ω; doba náběhu > 4 ns","range":"10 V až 4 kV","cmc":"3,0 %"},{"name":"zátěž 1 kΩ; doba náběhu > 4 ns","range":"20 V až 8 kV","cmc":"4,0 %"}],"technique":"Pomiar oscyloskopem wzorcowym z dzielnikiem rezystancyjnym","technique_en":"Measurement by a standard oscilloscope with a resistive divider","technique_zh":"用带电阻分压器的标准示波器测量","technique_cs":"Měření etalonovým osciloskopem s odporovým děličem","techniques":["Pomiar oscyloskopem wzorcowym z dzielnikiem rezystancyjnym"],"techniques_en":["Measurement by a standard oscilloscope with a resistive divider"],"techniques_zh":["用带电阻分压器的标准示波器测量"],"techniques_cs":["Měření etalonovým osciloskopem s odporovým děličem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nobciążenie 50 Ω; czas narastania > 4 ns od 10 V do 4 kV CMC 3,0 %\nobciążenie 1 kΩ; czas narastania > 4 ns od 20 V do 8 kV CMC 4,0 %\nPomiar oscyloskopem wzorcowym z dzielnikiem rezystancyjnym","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie impulsowe / generatory EFT / Burst Wzorcowanie – wielkości elektryczne Pomiar oscyloskopem wzorcowym z dzielnikiem rezystancyjnym obciążenie 50 Ω; czas narastania > 4 ns od 10 V do 4 kV CMC 3,0 % obciążenie 1 kΩ; czas narastania > 4 ns od 20 V do 8 kV CMC 4,0 % Impulsní napětí / Generátory EFT / Burst Kalibrace – elektrické veličiny Měření etalonovým osciloskopem s odporovým děličem zátěž 50 Ω; doba náběhu > 4 ns 10 V až 4 kV CMC 3,0 % zátěž 1 kΩ; doba náběhu > 4 ns 20 V až 8 kV CMC 4,0 % MK16 Napiecie impulsowe / generatory EFT / Burst Wzorcowanie – wielkosci elektryczne Pomiar oscyloskopem wzorcowym z dzielnikiem rezystancyjnym obciazenie 50 Ω; czas narastania > 4 ns od 10 V do 4 kV CMC 3,0 % obciazenie 1 kΩ; czas narastania > 4 ns od 20 V do 8 kV CMC 4,0 % Impulsni napeti / Generatory EFT / Burst Kalibrace – elektricke veliciny Mereni etalonovym osciloskopem s odporovym delicem zatez 50 Ω; doba nabehu > 4 ns 10 V az 4 kV CMC 3,0 % zatez 1 kΩ; doba nabehu > 4 ns 20 V az 8 kV CMC 4,0 % MK16","search_en":"Pulse voltage / EFT / Burst generators Calibration – electrical quantities Measurement by a standard oscilloscope with a resistive divider load 50 Ω; rise time > 4 ns 10 V to 4 kV CMC 3,0 % load 1 kΩ; rise time > 4 ns 20 V to 8 kV CMC 4,0 % MK16","search_zh":"脉冲电压 / EFT/Burst 发生器 校准 – 电学量 用带电阻分压器的标准示波器测量 负载 50 Ω；上升时间 > 4 ns 10 V 至 4 kV CMC 3,0 % 负载 1 kΩ；上升时间 > 4 ns 20 V 至 8 kV CMC 4,0 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a24ceb0ae65d58fc9c714b2","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Napięcie impulsowe / generatory udarowe, defektoskopy","test_object_en":"Pulse voltage / Surge generators, flaw detectors","test_object_zh":"脉冲电压 / 浪涌发生器、探伤仪","test_object_cs":"Impulsní napětí / Rázové generátory, defektoskopy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"czas narastania > 50 ns","range":"od 10 V do 30 kV","cmc":"3,0 %"}],"parameters_en":[{"name":"rise time > 50 ns","range":"10 V to 30 kV","cmc":"3,0 %"}],"parameters_zh":[{"name":"上升时间 > 50 ns","range":"10 V 至 30 kV","cmc":"3,0 %"}],"parameters_cs":[{"name":"doba náběhu > 50 ns","range":"10 V až 30 kV","cmc":"3,0 %"}],"technique":"Pomiar oscyloskopem wzorcowym z sondą napięciową","technique_en":"Measurement by a standard oscilloscope with a voltage probe","technique_zh":"用带电压探头的标准示波器测量","technique_cs":"Měření etalonovým osciloskopem s napěťovou sondou","techniques":["Pomiar oscyloskopem wzorcowym z sondą napięciową"],"techniques_en":["Measurement by a standard oscilloscope with a voltage probe"],"techniques_zh":["用带电压探头的标准示波器测量"],"techniques_cs":["Měření etalonovým osciloskopem s napěťovou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nczas narastania > 50 ns od 10 V do 30 kV CMC 3,0 %\nPomiar oscyloskopem wzorcowym z sondą napięciową","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie impulsowe / generatory udarowe, defektoskopy Wzorcowanie – wielkości elektryczne Pomiar oscyloskopem wzorcowym z sondą napięciową czas narastania > 50 ns od 10 V do 30 kV CMC 3,0 % Impulsní napětí / Rázové generátory, defektoskopy Kalibrace – elektrické veličiny Měření etalonovým osciloskopem s napěťovou sondou doba náběhu > 50 ns 10 V až 30 kV CMC 3,0 % MK16 Napiecie impulsowe / generatory udarowe, defektoskopy Wzorcowanie – wielkosci elektryczne Pomiar oscyloskopem wzorcowym z sonda napieciowa czas narastania > 50 ns od 10 V do 30 kV CMC 3,0 % Impulsni napeti / Razove generatory, defektoskopy Kalibrace – elektricke veliciny Mereni etalonovym osciloskopem s napetovou sondou doba nabehu > 50 ns 10 V az 30 kV CMC 3,0 % MK16","search_en":"Pulse voltage / Surge generators, flaw detectors Calibration – electrical quantities Measurement by a standard oscilloscope with a voltage probe rise time > 50 ns 10 V to 30 kV CMC 3,0 % MK16","search_zh":"脉冲电压 / 浪涌发生器、探伤仪 校准 – 电学量 用带电压探头的标准示波器测量 上升时间 > 50 ns 10 V 至 30 kV CMC 3,0 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b45ac024aa3a79c4376339c8","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / multimetry, amperomierze, testery, przetworniki, źródła i kalibratory prądu","test_object_en":"DC current / Multimeters, ammeters, testers, transducers, current sources and calibrators","test_object_zh":"直流电流 / 万用表、电流表、测试仪、变送器、电流源和校准器","test_object_cs":"Stejnosměrný proud / Multimetry, ampérmetry, testery, převodníky, zdroje a kalibrátory proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 pA do 20 nA","cmc":"0,60 % + 0,5 pA"},{"name":"","range":"od 20 nA do 1 µA","cmc":"0,25 %"}],"parameters_en":[{"name":"","range":"10 pA to 20 nA","cmc":"0,60 % + 0,5 pA"},{"name":"","range":"20 nA to 1 µA","cmc":"0,25 %"}],"parameters_zh":[{"name":"","range":"10 pA 至 20 nA","cmc":"0,60 % + 0,5 pA"},{"name":"","range":"20 nA 至 1 µA","cmc":"0,25 %"}],"parameters_cs":[{"name":"","range":"10 pA až 20 nA","cmc":"0,60 % + 0,5 pA"},{"name":"","range":"20 nA až 1 µA","cmc":"0,25 %"}],"technique":"Generowanie metodą Ohma lub pomiar bezpośredni pikoamperomierzem wzorcowym","technique_en":"Generation by Ohm's method or direct measurement by a standard picoammeter","technique_zh":"用欧姆法产生或用标准皮安表直接测量","technique_cs":"Generování Ohmovou metodou nebo přímé měření etalonovým pikoampérmetrem","techniques":["Generowanie metodą Ohma lub pomiar bezpośredni pikoamperomierzem wzorcowym"],"techniques_en":["Generation by Ohm's method or direct measurement by a standard picoammeter"],"techniques_zh":["用欧姆法产生或用标准皮安表直接测量"],"techniques_cs":["Generování Ohmovou metodou nebo přímé měření etalonovým pikoampérmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 10 pA do 20 nA CMC 0,60 % + 0,5 pA\nod 20 nA do 1 µA CMC 0,25 %\nGenerowanie metodą Ohma lub pomiar bezpośredni pikoamperomierzem wzorcowym","reference":"MK4, MK8, MK9","norm_bases":["MK4","MK8","MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / multimetry, amperomierze, testery, przetworniki, źródła i kalibratory prądu Wzorcowanie – wielkości elektryczne Generowanie metodą Ohma lub pomiar bezpośredni pikoamperomierzem wzorcowym od 10 pA do 20 nA CMC 0,60 % + 0,5 pA od 20 nA do 1 µA CMC 0,25 % Stejnosměrný proud / Multimetry, ampérmetry, testery, převodníky, zdroje a kalibrátory proudu Kalibrace – elektrické veličiny Generování Ohmovou metodou nebo přímé měření etalonovým pikoampérmetrem 10 pA až 20 nA CMC 0,60 % + 0,5 pA 20 nA až 1 µA CMC 0,25 % MK4, MK8, MK9 Prad staly / multimetry, amperomierze, testery, przetworniki, zrodla i kalibratory pradu Wzorcowanie – wielkosci elektryczne Generowanie metoda Ohma lub pomiar bezposredni pikoamperomierzem wzorcowym od 10 pA do 20 nA CMC 0,60 % + 0,5 pA od 20 nA do 1 µA CMC 0,25 % Stejnosmerny proud / Multimetry, ampermetry, testery, prevodniky, zdroje a kalibratory proudu Kalibrace – elektricke veliciny Generovani Ohmovou metodou nebo prime mereni etalonovym pikoampermetrem 10 pA az 20 nA CMC 0,60 % + 0,5 pA 20 nA az 1 µA CMC 0,25 % MK4, MK8, MK9","search_en":"DC current / Multimeters, ammeters, testers, transducers, current sources and calibrators Calibration – electrical quantities Generation by Ohm's method or direct measurement by a standard picoammeter 10 pA to 20 nA CMC 0,60 % + 0,5 pA 20 nA to 1 µA CMC 0,25 % MK4, MK8, MK9","search_zh":"直流电流 / 万用表、电流表、测试仪、变送器、电流源和校准器 校准 – 电学量 用欧姆法产生或用标准皮安表直接测量 10 pA 至 20 nA CMC 0,60 % + 0,5 pA 20 nA 至 1 µA CMC 0,25 % MK4, MK8, MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fb636bd507ebeccbfc7881df","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / multimetry, amperomierze, testery, przetworniki, źródła i kalibratory prądu","test_object_en":"DC current / Multimeters, ammeters, testers, transducers, current sources and calibrators","test_object_zh":"直流电流 / 万用表、电流表、测试仪、变送器、电流源和校准器","test_object_cs":"Stejnosměrný proud / Multimetry, ampérmetry, testery, převodníky, zdroje a kalibrátory proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 µA do 200 µA","cmc":"0,010 % + 0,4 nA"},{"name":"","range":"od 200 µA do 2 mA","cmc":"0,010 % + 4 nA"},{"name":"","range":"od 2 mA do 20 mA","cmc":"0,010 % + 40 nA"},{"name":"","range":"od 20 mA do 33 mA","cmc":"0,011 %"},{"name":"","range":"od 33 mA do 200 mA","cmc":"0,010 % + 1 µA"},{"name":"","range":"od 200 mA do 330 mA","cmc":"0,010 % + 2,5 µA"},{"name":"","range":"od 330 mA do 2 A","cmc":"0,020 % + 20 µA"}],"parameters_en":[{"name":"","range":"1 µA to 200 µA","cmc":"0,010 % + 0,4 nA"},{"name":"","range":"200 µA to 2 mA","cmc":"0,010 % + 4 nA"},{"name":"","range":"2 mA to 20 mA","cmc":"0,010 % + 40 nA"},{"name":"","range":"20 mA to 33 mA","cmc":"0,011 %"},{"name":"","range":"33 mA to 200 mA","cmc":"0,010 % + 1 µA"},{"name":"","range":"200 mA to 330 mA","cmc":"0,010 % + 2,5 µA"},{"name":"","range":"330 mA to 2 A","cmc":"0,020 % + 20 µA"}],"parameters_zh":[{"name":"","range":"1 µA 至 200 µA","cmc":"0,010 % + 0,4 nA"},{"name":"","range":"200 µA 至 2 mA","cmc":"0,010 % + 4 nA"},{"name":"","range":"2 mA 至 20 mA","cmc":"0,010 % + 40 nA"},{"name":"","range":"20 mA 至 33 mA","cmc":"0,011 %"},{"name":"","range":"33 mA 至 200 mA","cmc":"0,010 % + 1 µA"},{"name":"","range":"200 mA 至 330 mA","cmc":"0,010 % + 2,5 µA"},{"name":"","range":"330 mA 至 2 A","cmc":"0,020 % + 20 µA"}],"parameters_cs":[{"name":"","range":"1 µA až 200 µA","cmc":"0,010 % + 0,4 nA"},{"name":"","range":"200 µA až 2 mA","cmc":"0,010 % + 4 nA"},{"name":"","range":"2 mA až 20 mA","cmc":"0,010 % + 40 nA"},{"name":"","range":"20 mA až 33 mA","cmc":"0,011 %"},{"name":"","range":"33 mA až 200 mA","cmc":"0,010 % + 1 µA"},{"name":"","range":"200 mA až 330 mA","cmc":"0,010 % + 2,5 µA"},{"name":"","range":"330 mA až 2 A","cmc":"0,020 % + 20 µA"}],"technique":"Multimetr wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter: comparison or direct measurement","technique_zh":"标准万用表：比较或直接测量","technique_cs":"Etalonový multimetr: porovnání nebo přímé měření","techniques":["Multimetr wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter: comparison or direct measurement"],"techniques_zh":["标准万用表：比较或直接测量"],"techniques_cs":["Etalonový multimetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 µA do 200 µA CMC 0,010 % + 0,4 nA\nod 200 µA do 2 mA CMC 0,010 % + 4 nA\nod 2 mA do 20 mA CMC 0,010 % + 40 nA\nod 20 mA do 33 mA CMC 0,011 %\nod 33 mA do 200 mA CMC 0,010 % + 1 µA\nod 200 mA do 330 mA CMC 0,010 % + 2,5 µA\nod 330 mA do 2 A CMC 0,020 % + 20 µA\nMultimetr wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK4, MK8, MK9","norm_bases":["MK4","MK8","MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / multimetry, amperomierze, testery, przetworniki, źródła i kalibratory prądu Wzorcowanie – wielkości elektryczne Multimetr wzorcowy: porównanie lub pomiar bezpośredni od 1 µA do 200 µA CMC 0,010 % + 0,4 nA od 200 µA do 2 mA CMC 0,010 % + 4 nA od 2 mA do 20 mA CMC 0,010 % + 40 nA od 20 mA do 33 mA CMC 0,011 % od 33 mA do 200 mA CMC 0,010 % + 1 µA od 200 mA do 330 mA CMC 0,010 % + 2,5 µA od 330 mA do 2 A CMC 0,020 % + 20 µA Stejnosměrný proud / Multimetry, ampérmetry, testery, převodníky, zdroje a kalibrátory proudu Kalibrace – elektrické veličiny Etalonový multimetr: porovnání nebo přímé měření 1 µA až 200 µA CMC 0,010 % + 0,4 nA 200 µA až 2 mA CMC 0,010 % + 4 nA 2 mA až 20 mA CMC 0,010 % + 40 nA 20 mA až 33 mA CMC 0,011 % 33 mA až 200 mA CMC 0,010 % + 1 µA 200 mA až 330 mA CMC 0,010 % + 2,5 µA 330 mA až 2 A CMC 0,020 % + 20 µA MK4, MK8, MK9 Prad staly / multimetry, amperomierze, testery, przetworniki, zrodla i kalibratory pradu Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy: porownanie lub pomiar bezposredni od 1 µA do 200 µA CMC 0,010 % + 0,4 nA od 200 µA do 2 mA CMC 0,010 % + 4 nA od 2 mA do 20 mA CMC 0,010 % + 40 nA od 20 mA do 33 mA CMC 0,011 % od 33 mA do 200 mA CMC 0,010 % + 1 µA od 200 mA do 330 mA CMC 0,010 % + 2,5 µA od 330 mA do 2 A CMC 0,020 % + 20 µA Stejnosmerny proud / Multimetry, ampermetry, testery, prevodniky, zdroje a kalibratory proudu Kalibrace – elektricke veliciny Etalonovy multimetr: porovnani nebo prime mereni 1 µA az 200 µA CMC 0,010 % + 0,4 nA 200 µA az 2 mA CMC 0,010 % + 4 nA 2 mA az 20 mA CMC 0,010 % + 40 nA 20 mA az 33 mA CMC 0,011 % 33 mA az 200 mA CMC 0,010 % + 1 µA 200 mA az 330 mA CMC 0,010 % + 2,5 µA 330 mA az 2 A CMC 0,020 % + 20 µA MK4, MK8, MK9","search_en":"DC current / Multimeters, ammeters, testers, transducers, current sources and calibrators Calibration – electrical quantities Standard multimeter: comparison or direct measurement 1 µA to 200 µA CMC 0,010 % + 0,4 nA 200 µA to 2 mA CMC 0,010 % + 4 nA 2 mA to 20 mA CMC 0,010 % + 40 nA 20 mA to 33 mA CMC 0,011 % 33 mA to 200 mA CMC 0,010 % + 1 µA 200 mA to 330 mA CMC 0,010 % + 2,5 µA 330 mA to 2 A CMC 0,020 % + 20 µA MK4, MK8, MK9","search_zh":"直流电流 / 万用表、电流表、测试仪、变送器、电流源和校准器 校准 – 电学量 标准万用表：比较或直接测量 1 µA 至 200 µA CMC 0,010 % + 0,4 nA 200 µA 至 2 mA CMC 0,010 % + 4 nA 2 mA 至 20 mA CMC 0,010 % + 40 nA 20 mA 至 33 mA CMC 0,011 % 33 mA 至 200 mA CMC 0,010 % + 1 µA 200 mA 至 330 mA CMC 0,010 % + 2,5 µA 330 mA 至 2 A CMC 0,020 % + 20 µA MK4, MK8, MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f9009d53e714b750bb65f742","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / multimetry, amperomierze, testery, przetworniki, źródła i kalibratory prądu","test_object_en":"DC current / Multimeters, ammeters, testers, transducers, current sources and calibrators","test_object_zh":"直流电流 / 万用表、电流表、测试仪、变送器、电流源和校准器","test_object_cs":"Stejnosměrný proud / Multimetry, ampérmetry, testery, převodníky, zdroje a kalibrátory proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 2 A do 3 A","cmc":"0,038 % + 40 µA"},{"name":"","range":"od 3 A do 105 A","cmc":"0,050 %"}],"parameters_en":[{"name":"","range":"2 A to 3 A","cmc":"0,038 % + 40 µA"},{"name":"","range":"3 A to 105 A","cmc":"0,050 %"}],"parameters_zh":[{"name":"","range":"2 A 至 3 A","cmc":"0,038 % + 40 µA"},{"name":"","range":"3 A 至 105 A","cmc":"0,050 %"}],"parameters_cs":[{"name":"","range":"2 A až 3 A","cmc":"0,038 % + 40 µA"},{"name":"","range":"3 A až 105 A","cmc":"0,050 %"}],"technique":"Multimetr wzorcowy z bocznikiem: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter with a shunt: comparison or direct measurement","technique_zh":"带分流器的标准万用表：比较或直接测量","technique_cs":"Etalonový multimetr s bočníkem: porovnání nebo přímé měření","techniques":["Multimetr wzorcowy z bocznikiem: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter with a shunt: comparison or direct measurement"],"techniques_zh":["带分流器的标准万用表：比较或直接测量"],"techniques_cs":["Etalonový multimetr s bočníkem: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 2 A do 3 A CMC 0,038 % + 40 µA\nod 3 A do 105 A CMC 0,050 %\nMultimetr wzorcowy z bocznikiem: porównanie lub pomiar bezpośredni","reference":"MK4, MK8, MK9","norm_bases":["MK4","MK8","MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / multimetry, amperomierze, testery, przetworniki, źródła i kalibratory prądu Wzorcowanie – wielkości elektryczne Multimetr wzorcowy z bocznikiem: porównanie lub pomiar bezpośredni od 2 A do 3 A CMC 0,038 % + 40 µA od 3 A do 105 A CMC 0,050 % Stejnosměrný proud / Multimetry, ampérmetry, testery, převodníky, zdroje a kalibrátory proudu Kalibrace – elektrické veličiny Etalonový multimetr s bočníkem: porovnání nebo přímé měření 2 A až 3 A CMC 0,038 % + 40 µA 3 A až 105 A CMC 0,050 % MK4, MK8, MK9 Prad staly / multimetry, amperomierze, testery, przetworniki, zrodla i kalibratory pradu Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy z bocznikiem: porownanie lub pomiar bezposredni od 2 A do 3 A CMC 0,038 % + 40 µA od 3 A do 105 A CMC 0,050 % Stejnosmerny proud / Multimetry, ampermetry, testery, prevodniky, zdroje a kalibratory proudu Kalibrace – elektricke veliciny Etalonovy multimetr s bocnikem: porovnani nebo prime mereni 2 A az 3 A CMC 0,038 % + 40 µA 3 A az 105 A CMC 0,050 % MK4, MK8, MK9","search_en":"DC current / Multimeters, ammeters, testers, transducers, current sources and calibrators Calibration – electrical quantities Standard multimeter with a shunt: comparison or direct measurement 2 A to 3 A CMC 0,038 % + 40 µA 3 A to 105 A CMC 0,050 % MK4, MK8, MK9","search_zh":"直流电流 / 万用表、电流表、测试仪、变送器、电流源和校准器 校准 – 电学量 带分流器的标准万用表：比较或直接测量 2 A 至 3 A CMC 0,038 % + 40 µA 3 A 至 105 A CMC 0,050 % MK4, MK8, MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7b65c43aff12ee7af96a9b47","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / źródła prądu, spawarki","test_object_en":"DC current / Current sources, welders","test_object_zh":"直流电流 / 电流源、焊机","test_object_cs":"Stejnosměrný proud / Zdroje proudu, svářečky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 105 A do 5000 A","cmc":"1,5 %"}],"parameters_en":[{"name":"","range":"105 A to 5000 A","cmc":"1,5 %"}],"parameters_zh":[{"name":"","range":"105 A 至 5000 A","cmc":"1,5 %"}],"parameters_cs":[{"name":"","range":"105 A až 5000 A","cmc":"1,5 %"}],"technique":"Pomiar multimetrem wzorcowym z cęgami prądowymi","technique_en":"Measurement by a standard multimeter with current clamps","technique_zh":"用带电流钳的标准万用表测量","technique_cs":"Měření etalonovým multimetrem s proudovými kleštěmi","techniques":["Pomiar multimetrem wzorcowym z cęgami prądowymi"],"techniques_en":["Measurement by a standard multimeter with current clamps"],"techniques_zh":["用带电流钳的标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem s proudovými kleštěmi"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 105 A do 5000 A CMC 1,5 %\nPomiar multimetrem wzorcowym z cęgami prądowymi","reference":"MK9","norm_bases":["MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu, spawarki Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym z cęgami prądowymi od 105 A do 5000 A CMC 1,5 % Stejnosměrný proud / Zdroje proudu, svářečky Kalibrace – elektrické veličiny Měření etalonovým multimetrem s proudovými kleštěmi 105 A až 5000 A CMC 1,5 % MK9 Prad staly / zrodla pradu, spawarki Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym z cegami pradowymi od 105 A do 5000 A CMC 1,5 % Stejnosmerny proud / Zdroje proudu, svarecky Kalibrace – elektricke veliciny Mereni etalonovym multimetrem s proudovymi klestemi 105 A az 5000 A CMC 1,5 % MK9","search_en":"DC current / Current sources, welders Calibration – electrical quantities Measurement by a standard multimeter with current clamps 105 A to 5000 A CMC 1,5 % MK9","search_zh":"直流电流 / 电流源、焊机 校准 – 电学量 用带电流钳的标准万用表测量 105 A 至 5000 A CMC 1,5 % MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"05d3008446dc67ce070d561f","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / multimetry cęgowe","test_object_en":"DC current / Clamp multimeters","test_object_zh":"直流电流 / 钳形万用表","test_object_cs":"Stejnosměrný proud / Klešťové multimetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 A do 105 A","cmc":"0,50 %"}],"parameters_en":[{"name":"","range":"1 A to 105 A","cmc":"0,50 %"}],"parameters_zh":[{"name":"","range":"1 A 至 105 A","cmc":"0,50 %"}],"parameters_cs":[{"name":"","range":"1 A až 105 A","cmc":"0,50 %"}],"technique":"Generowanie kalibratorem wzorcowym do przewodu prostego","technique_en":"Generation by a standard calibrator into a straight conductor","technique_zh":"用标准校准器向直导线产生电流","technique_cs":"Generování etalonovým kalibrátorem do přímého vodiče","techniques":["Generowanie kalibratorem wzorcowym do przewodu prostego"],"techniques_en":["Generation by a standard calibrator into a straight conductor"],"techniques_zh":["用标准校准器向直导线产生电流"],"techniques_cs":["Generování etalonovým kalibrátorem do přímého vodiče"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 A do 105 A CMC 0,50 %\nGenerowanie kalibratorem wzorcowym do przewodu prostego","reference":"MK4, MK8","norm_bases":["MK4","MK8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / multimetry cęgowe Wzorcowanie – wielkości elektryczne Generowanie kalibratorem wzorcowym do przewodu prostego od 1 A do 105 A CMC 0,50 % Stejnosměrný proud / Klešťové multimetry Kalibrace – elektrické veličiny Generování etalonovým kalibrátorem do přímého vodiče 1 A až 105 A CMC 0,50 % MK4, MK8 Prad staly / multimetry cegowe Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem wzorcowym do przewodu prostego od 1 A do 105 A CMC 0,50 % Stejnosmerny proud / Klestove multimetry Kalibrace – elektricke veliciny Generovani etalonovym kalibratorem do primeho vodice 1 A az 105 A CMC 0,50 % MK4, MK8","search_en":"DC current / Clamp multimeters Calibration – electrical quantities Generation by a standard calibrator into a straight conductor 1 A to 105 A CMC 0,50 % MK4, MK8","search_zh":"直流电流 / 钳形万用表 校准 – 电学量 用标准校准器向直导线产生电流 1 A 至 105 A CMC 0,50 % MK4, MK8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b230751e96c155ae8e67613","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / multimetry cęgowe","test_object_en":"DC current / Clamp multimeters","test_object_zh":"直流电流 / 钳形万用表","test_object_cs":"Stejnosměrný proud / Klešťové multimetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 105 A do 1050 A","cmc":"1,5 %"}],"parameters_en":[{"name":"","range":"105 A to 1050 A","cmc":"1,5 %"}],"parameters_zh":[{"name":"","range":"105 A 至 1050 A","cmc":"1,5 %"}],"parameters_cs":[{"name":"","range":"105 A až 1050 A","cmc":"1,5 %"}],"technique":"Generowanie kalibratorem wzorcowym do cewki dziesięciozwojowej","technique_en":"Generation by a standard calibrator into a ten-turn coil","technique_zh":"用标准校准器向十匝线圈产生电流","technique_cs":"Generování etalonovým kalibrátorem do desetizávitové cívky","techniques":["Generowanie kalibratorem wzorcowym do cewki dziesięciozwojowej"],"techniques_en":["Generation by a standard calibrator into a ten-turn coil"],"techniques_zh":["用标准校准器向十匝线圈产生电流"],"techniques_cs":["Generování etalonovým kalibrátorem do desetizávitové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 105 A do 1050 A CMC 1,5 %\nGenerowanie kalibratorem wzorcowym do cewki dziesięciozwojowej","reference":"MK4, MK8","norm_bases":["MK4","MK8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / multimetry cęgowe Wzorcowanie – wielkości elektryczne Generowanie kalibratorem wzorcowym do cewki dziesięciozwojowej od 105 A do 1050 A CMC 1,5 % Stejnosměrný proud / Klešťové multimetry Kalibrace – elektrické veličiny Generování etalonovým kalibrátorem do desetizávitové cívky 105 A až 1050 A CMC 1,5 % MK4, MK8 Prad staly / multimetry cegowe Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem wzorcowym do cewki dziesieciozwojowej od 105 A do 1050 A CMC 1,5 % Stejnosmerny proud / Klestove multimetry Kalibrace – elektricke veliciny Generovani etalonovym kalibratorem do desetizavitove civky 105 A az 1050 A CMC 1,5 % MK4, MK8","search_en":"DC current / Clamp multimeters Calibration – electrical quantities Generation by a standard calibrator into a ten-turn coil 105 A to 1050 A CMC 1,5 % MK4, MK8","search_zh":"直流电流 / 钳形万用表 校准 – 电学量 用标准校准器向十匝线圈产生电流 105 A 至 1050 A CMC 1,5 % MK4, MK8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2e3e975568f82b9994e6c981","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu","test_object_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators","test_object_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器","test_object_cs":"Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 5 kHz","range":"od 9 µA do 29 µA","cmc":"0,040 % + 20 nA"},{"name":"10 Hz do 5 kHz","range":"od 29 µA do 200 µA","cmc":"0,040 % + 20 nA"},{"name":"5 kHz do 10 kHz","range":"od 29 µA do 200 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz do 5 kHz","range":"od 200 µA do 330 µA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz do 10 kHz","range":"od 200 µA do 330 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz do 5 kHz","range":"od 330 µA do 2 mA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz do 10 kHz","range":"od 330 µA do 2 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz do 5 kHz","range":"od 2 mA do 3,3 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz do 10 kHz","range":"od 2 mA do 3,3 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz do 5 kHz","range":"od 3,3 mA do 20 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz do 10 kHz","range":"od 3,3 mA do 20 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz do 30 kHz","range":"od 3,3 mA do 20 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz do 45 Hz","range":"od 20 mA do 33 mA","cmc":"0,036 % + 20 µA"},{"name":"45 Hz do 1 kHz","range":"od 20 mA do 33 mA","cmc":"0,040 % + 2 µA"},{"name":"1 kHz do 5 kHz","range":"od 20 mA do 33 mA","cmc":"0,080 % + 2 µA"},{"name":"5 kHz do 10 kHz","range":"od 20 mA do 33 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz do 30 kHz","range":"od 20 mA do 33 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz do 5 kHz","range":"od 33 mA do 200 mA","cmc":"0,036 % + 20 µA"},{"name":"5 kHz do 10 kHz","range":"od 33 mA do 200 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz do 30 kHz","range":"od 33 mA do 200 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz do 45 Hz","range":"od 200 mA do 330 mA","cmc":"0,053 % + 200 µA"},{"name":"45 Hz do 1 kHz","range":"od 200 mA do 330 mA","cmc":"0,040 % + 20 µA"},{"name":"1 kHz do 5 kHz","range":"od 200 mA do 330 mA","cmc":"0,10 % + 50 µA"},{"name":"5 kHz do 10 kHz","range":"od 200 mA do 330 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz do 30 kHz","range":"od 200 mA do 330 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz do 45 Hz","range":"od 330 mA do 1,1 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz do 1 kHz","range":"od 330 mA do 1,1 A","cmc":"0,050 % + 100 µA"},{"name":"1 kHz do 5 kHz","range":"od 330 mA do 1,1 A","cmc":"0,069 % + 320 µA"},{"name":"10 Hz do 45 Hz","range":"od 1,1 A do 2 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz do 1 kHz","range":"od 1,1 A do 2 A","cmc":"0,060 % + 100 µA"},{"name":"1 kHz do 5 kHz","range":"od 1,1 A do 2 A","cmc":"0,069 % + 320 µA"}],"parameters_en":[{"name":"10 Hz to 5 kHz","range":"9 µA to 29 µA","cmc":"0,040 % + 20 nA"},{"name":"10 Hz to 5 kHz","range":"29 µA to 200 µA","cmc":"0,040 % + 20 nA"},{"name":"5 kHz to 10 kHz","range":"29 µA to 200 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz to 5 kHz","range":"200 µA to 330 µA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz to 10 kHz","range":"200 µA to 330 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz to 5 kHz","range":"330 µA to 2 mA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz to 10 kHz","range":"330 µA to 2 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz to 5 kHz","range":"2 mA to 3,3 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz to 10 kHz","range":"2 mA to 3,3 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz to 5 kHz","range":"3,3 mA to 20 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz to 10 kHz","range":"3,3 mA to 20 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz to 30 kHz","range":"3,3 mA to 20 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz to 45 Hz","range":"20 mA to 33 mA","cmc":"0,036 % + 20 µA"},{"name":"45 Hz to 1 kHz","range":"20 mA to 33 mA","cmc":"0,040 % + 2 µA"},{"name":"1 kHz to 5 kHz","range":"20 mA to 33 mA","cmc":"0,080 % + 2 µA"},{"name":"5 kHz to 10 kHz","range":"20 mA to 33 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz to 30 kHz","range":"20 mA to 33 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz to 5 kHz","range":"33 mA to 200 mA","cmc":"0,036 % + 20 µA"},{"name":"5 kHz to 10 kHz","range":"33 mA to 200 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz to 30 kHz","range":"33 mA to 200 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz to 45 Hz","range":"200 mA to 330 mA","cmc":"0,053 % + 200 µA"},{"name":"45 Hz to 1 kHz","range":"200 mA to 330 mA","cmc":"0,040 % + 20 µA"},{"name":"1 kHz to 5 kHz","range":"200 mA to 330 mA","cmc":"0,10 % + 50 µA"},{"name":"5 kHz to 10 kHz","range":"200 mA to 330 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz to 30 kHz","range":"200 mA to 330 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz to 45 Hz","range":"330 mA to 1,1 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz to 1 kHz","range":"330 mA to 1,1 A","cmc":"0,050 % + 100 µA"},{"name":"1 kHz to 5 kHz","range":"330 mA to 1,1 A","cmc":"0,069 % + 320 µA"},{"name":"10 Hz to 45 Hz","range":"1,1 A to 2 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz to 1 kHz","range":"1,1 A to 2 A","cmc":"0,060 % + 100 µA"},{"name":"1 kHz to 5 kHz","range":"1,1 A to 2 A","cmc":"0,069 % + 320 µA"}],"parameters_zh":[{"name":"10 Hz 至 5 kHz","range":"9 µA 至 29 µA","cmc":"0,040 % + 20 nA"},{"name":"10 Hz 至 5 kHz","range":"29 µA 至 200 µA","cmc":"0,040 % + 20 nA"},{"name":"5 kHz 至 10 kHz","range":"29 µA 至 200 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz 至 5 kHz","range":"200 µA 至 330 µA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz 至 10 kHz","range":"200 µA 至 330 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz 至 5 kHz","range":"330 µA 至 2 mA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz 至 10 kHz","range":"330 µA 至 2 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz 至 5 kHz","range":"2 mA 至 3,3 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz 至 10 kHz","range":"2 mA 至 3,3 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz 至 5 kHz","range":"3,3 mA 至 20 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz 至 10 kHz","range":"3,3 mA 至 20 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz 至 30 kHz","range":"3,3 mA 至 20 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz 至 45 Hz","range":"20 mA 至 33 mA","cmc":"0,036 % + 20 µA"},{"name":"45 Hz 至 1 kHz","range":"20 mA 至 33 mA","cmc":"0,040 % + 2 µA"},{"name":"1 kHz 至 5 kHz","range":"20 mA 至 33 mA","cmc":"0,080 % + 2 µA"},{"name":"5 kHz 至 10 kHz","range":"20 mA 至 33 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz 至 30 kHz","range":"20 mA 至 33 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz 至 5 kHz","range":"33 mA 至 200 mA","cmc":"0,036 % + 20 µA"},{"name":"5 kHz 至 10 kHz","range":"33 mA 至 200 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz 至 30 kHz","range":"33 mA 至 200 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz 至 45 Hz","range":"200 mA 至 330 mA","cmc":"0,053 % + 200 µA"},{"name":"45 Hz 至 1 kHz","range":"200 mA 至 330 mA","cmc":"0,040 % + 20 µA"},{"name":"1 kHz 至 5 kHz","range":"200 mA 至 330 mA","cmc":"0,10 % + 50 µA"},{"name":"5 kHz 至 10 kHz","range":"200 mA 至 330 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz 至 30 kHz","range":"200 mA 至 330 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz 至 45 Hz","range":"330 mA 至 1,1 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz 至 1 kHz","range":"330 mA 至 1,1 A","cmc":"0,050 % + 100 µA"},{"name":"1 kHz 至 5 kHz","range":"330 mA 至 1,1 A","cmc":"0,069 % + 320 µA"},{"name":"10 Hz 至 45 Hz","range":"1,1 A 至 2 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz 至 1 kHz","range":"1,1 A 至 2 A","cmc":"0,060 % + 100 µA"},{"name":"1 kHz 至 5 kHz","range":"1,1 A 至 2 A","cmc":"0,069 % + 320 µA"}],"parameters_cs":[{"name":"10 Hz až 5 kHz","range":"9 µA až 29 µA","cmc":"0,040 % + 20 nA"},{"name":"10 Hz až 5 kHz","range":"29 µA až 200 µA","cmc":"0,040 % + 20 nA"},{"name":"5 kHz až 10 kHz","range":"29 µA až 200 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz až 5 kHz","range":"200 µA až 330 µA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz až 10 kHz","range":"200 µA až 330 µA","cmc":"0,80 % + 200 nA"},{"name":"10 Hz až 5 kHz","range":"330 µA až 2 mA","cmc":"0,033 % + 200 nA"},{"name":"5 kHz až 10 kHz","range":"330 µA až 2 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz až 5 kHz","range":"2 mA až 3,3 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz až 10 kHz","range":"2 mA až 3,3 mA","cmc":"0,50 % + 300 nA"},{"name":"10 Hz až 5 kHz","range":"3,3 mA až 20 mA","cmc":"0,036 % + 2 µA"},{"name":"5 kHz až 10 kHz","range":"3,3 mA až 20 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz až 30 kHz","range":"3,3 mA až 20 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz až 45 Hz","range":"20 mA až 33 mA","cmc":"0,036 % + 20 µA"},{"name":"45 Hz až 1 kHz","range":"20 mA až 33 mA","cmc":"0,040 % + 2 µA"},{"name":"1 kHz až 5 kHz","range":"20 mA až 33 mA","cmc":"0,080 % + 2 µA"},{"name":"5 kHz až 10 kHz","range":"20 mA až 33 mA","cmc":"0,20 % + 3 µA"},{"name":"10 kHz až 30 kHz","range":"20 mA až 33 mA","cmc":"0,40 % + 4 µA"},{"name":"10 Hz až 5 kHz","range":"33 mA až 200 mA","cmc":"0,036 % + 20 µA"},{"name":"5 kHz až 10 kHz","range":"33 mA až 200 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz až 30 kHz","range":"33 mA až 200 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz až 45 Hz","range":"200 mA až 330 mA","cmc":"0,053 % + 200 µA"},{"name":"45 Hz až 1 kHz","range":"200 mA až 330 mA","cmc":"0,040 % + 20 µA"},{"name":"1 kHz až 5 kHz","range":"200 mA až 330 mA","cmc":"0,10 % + 50 µA"},{"name":"5 kHz až 10 kHz","range":"200 mA až 330 mA","cmc":"0,20 % + 100 µA"},{"name":"10 kHz až 30 kHz","range":"200 mA až 330 mA","cmc":"0,40 % + 200 µA"},{"name":"10 Hz až 45 Hz","range":"330 mA až 1,1 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz až 1 kHz","range":"330 mA až 1,1 A","cmc":"0,050 % + 100 µA"},{"name":"1 kHz až 5 kHz","range":"330 mA až 1,1 A","cmc":"0,069 % + 320 µA"},{"name":"10 Hz až 45 Hz","range":"1,1 A až 2 A","cmc":"0,053 % + 200 µA"},{"name":"45 Hz až 1 kHz","range":"1,1 A až 2 A","cmc":"0,060 % + 100 µA"},{"name":"1 kHz až 5 kHz","range":"1,1 A až 2 A","cmc":"0,069 % + 320 µA"}],"technique":"Multimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter or calibrator: comparison or direct measurement","technique_zh":"标准万用表或校准器：比较或直接测量","technique_cs":"Etalonový multimetr nebo kalibrátor: porovnání nebo přímé měření","techniques":["Multimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter or calibrator: comparison or direct measurement"],"techniques_zh":["标准万用表或校准器：比较或直接测量"],"techniques_cs":["Etalonový multimetr nebo kalibrátor: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 5 kHz od 9 µA do 29 µA CMC 0,040 % + 20 nA\n10 Hz do 5 kHz od 29 µA do 200 µA CMC 0,040 % + 20 nA\n5 kHz do 10 kHz od 29 µA do 200 µA CMC 0,80 % + 200 nA\n10 Hz do 5 kHz od 200 µA do 330 µA CMC 0,033 % + 200 nA\n5 kHz do 10 kHz od 200 µA do 330 µA CMC 0,80 % + 200 nA\n10 Hz do 5 kHz od 330 µA do 2 mA CMC 0,033 % + 200 nA\n5 kHz do 10 kHz od 330 µA do 2 mA CMC 0,50 % + 300 nA\n10 Hz do 5 kHz od 2 mA do 3,3 mA CMC 0,036 % + 2 µA\n5 kHz do 10 kHz od 2 mA do 3,3 mA CMC 0,50 % + 300 nA\n10 Hz do 5 kHz od 3,3 mA do 20 mA CMC 0,036 % + 2 µA\n5 kHz do 10 kHz od 3,3 mA do 20 mA CMC 0,20 % + 3 µA\n10 kHz do 30 kHz od 3,3 mA do 20 mA CMC 0,40 % + 4 µA\n10 Hz do 45 Hz od 20 mA do 33 mA CMC 0,036 % + 20 µA\n45 Hz do 1 kHz od 20 mA do 33 mA CMC 0,040 % + 2 µA\n1 kHz do 5 kHz od 20 mA do 33 mA CMC 0,080 % + 2 µA\n5 kHz do 10 kHz od 20 mA do 33 mA CMC 0,20 % + 3 µA\n10 kHz do 30 kHz od 20 mA do 33 mA CMC 0,40 % + 4 µA\n10 Hz do 5 kHz od 33 mA do 200 mA CMC 0,036 % + 20 µA\n5 kHz do 10 kHz od 33 mA do 200 mA CMC 0,20 % + 100 µA\n10 kHz do 30 kHz od 33 mA do 200 mA CMC 0,40 % + 200 µA\n10 Hz do 45 Hz od 200 mA do 330 mA CMC 0,053 % + 200 µA\n45 Hz do 1 kHz od 200 mA do 330 mA CMC 0,040 % + 20 µA\n1 kHz do 5 kHz od 200 mA do 330 mA CMC 0,10 % + 50 µA\n5 kHz do 10 kHz od 200 mA do 330 mA CMC 0,20 % + 100 µA\n10 kHz do 30 kHz od 200 mA do 330 mA CMC 0,40 % + 200 µA\n10 Hz do 45 Hz od 330 mA do 1,1 A CMC 0,053 % + 200 µA\n45 Hz do 1 kHz od 330 mA do 1,1 A CMC 0,050 % + 100 µA\n1 kHz do 5 kHz od 330 mA do 1,1 A CMC 0,069 % + 320 µA\n10 Hz do 45 Hz od 1,1 A do 2 A CMC 0,053 % + 200 µA\n45 Hz do 1 kHz od 1,1 A do 2 A CMC 0,060 % + 100 µA\n1 kHz do 5 kHz od 1,1 A do 2 A CMC 0,069 % + 320 µA\nMultimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK4, MK8, MK9, MK11","norm_bases":["MK4","MK8","MK9","MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu Wzorcowanie – wielkości elektryczne Multimetr lub kalibrator wzorcowy: porównanie lub pomiar bezpośredni 10 Hz do 5 kHz od 9 µA do 29 µA CMC 0,040 % + 20 nA 10 Hz do 5 kHz od 29 µA do 200 µA CMC 0,040 % + 20 nA 5 kHz do 10 kHz od 29 µA do 200 µA CMC 0,80 % + 200 nA 10 Hz do 5 kHz od 200 µA do 330 µA CMC 0,033 % + 200 nA 5 kHz do 10 kHz od 200 µA do 330 µA CMC 0,80 % + 200 nA 10 Hz do 5 kHz od 330 µA do 2 mA CMC 0,033 % + 200 nA 5 kHz do 10 kHz od 330 µA do 2 mA CMC 0,50 % + 300 nA 10 Hz do 5 kHz od 2 mA do 3,3 mA CMC 0,036 % + 2 µA 5 kHz do 10 kHz od 2 mA do 3,3 mA CMC 0,50 % + 300 nA 10 Hz do 5 kHz od 3,3 mA do 20 mA CMC 0,036 % + 2 µA 5 kHz do 10 kHz od 3,3 mA do 20 mA CMC 0,20 % + 3 µA 10 kHz do 30 kHz od 3,3 mA do 20 mA CMC 0,40 % + 4 µA 10 Hz do 45 Hz od 20 mA do 33 mA CMC 0,036 % + 20 µA 45 Hz do 1 kHz od 20 mA do 33 mA CMC 0,040 % + 2 µA 1 kHz do 5 kHz od 20 mA do 33 mA CMC 0,080 % + 2 µA 5 kHz do 10 kHz od 20 mA do 33 mA CMC 0,20 % + 3 µA 10 kHz do 30 kHz od 20 mA do 33 mA CMC 0,40 % + 4 µA 10 Hz do 5 kHz od 33 mA do 200 mA CMC 0,036 % + 20 µA 5 kHz do 10 kHz od 33 mA do 200 mA CMC 0,20 % + 100 µA 10 kHz do 30 kHz od 33 mA do 200 mA CMC 0,40 % + 200 µA 10 Hz do 45 Hz od 200 mA do 330 mA CMC 0,053 % + 200 µA 45 Hz do 1 kHz od 200 mA do 330 mA CMC 0,040 % + 20 µA 1 kHz do 5 kHz od 200 mA do 330 mA CMC 0,10 % + 50 µA 5 kHz do 10 kHz od 200 mA do 330 mA CMC 0,20 % + 100 µA 10 kHz do 30 kHz od 200 mA do 330 mA CMC 0,40 % + 200 µA 10 Hz do 45 Hz od 330 mA do 1,1 A CMC 0,053 % + 200 µA 45 Hz do 1 kHz od 330 mA do 1,1 A CMC 0,050 % + 100 µA 1 kHz do 5 kHz od 330 mA do 1,1 A CMC 0,069 % + 320 µA 10 Hz do 45 Hz od 1,1 A do 2 A CMC 0,053 % + 200 µA 45 Hz do 1 kHz od 1,1 A do 2 A CMC 0,060 % + 100 µA 1 kHz do 5 kHz od 1,1 A do 2 A CMC 0,069 % + 320 µA Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu Kalibrace – elektrické veličiny Etalonový multimetr nebo kalibrátor: porovnání nebo přímé měření 10 Hz až 5 kHz 9 µA až 29 µA CMC 0,040 % + 20 nA 10 Hz až 5 kHz 29 µA až 200 µA CMC 0,040 % + 20 nA 5 kHz až 10 kHz 29 µA až 200 µA CMC 0,80 % + 200 nA 10 Hz až 5 kHz 200 µA až 330 µA CMC 0,033 % + 200 nA 5 kHz až 10 kHz 200 µA až 330 µA CMC 0,80 % + 200 nA 10 Hz až 5 kHz 330 µA až 2 mA CMC 0,033 % + 200 nA 5 kHz až 10 kHz 330 µA až 2 mA CMC 0,50 % + 300 nA 10 Hz až 5 kHz 2 mA až 3,3 mA CMC 0,036 % + 2 µA 5 kHz až 10 kHz 2 mA až 3,3 mA CMC 0,50 % + 300 nA 10 Hz až 5 kHz 3,3 mA až 20 mA CMC 0,036 % + 2 µA 5 kHz až 10 kHz 3,3 mA až 20 mA CMC 0,20 % + 3 µA 10 kHz až 30 kHz 3,3 mA až 20 mA CMC 0,40 % + 4 µA 10 Hz až 45 Hz 20 mA až 33 mA CMC 0,036 % + 20 µA 45 Hz až 1 kHz 20 mA až 33 mA CMC 0,040 % + 2 µA 1 kHz až 5 kHz 20 mA až 33 mA CMC 0,080 % + 2 µA 5 kHz až 10 kHz 20 mA až 33 mA CMC 0,20 % + 3 µA 10 kHz až 30 kHz 20 mA až 33 mA CMC 0,40 % + 4 µA 10 Hz až 5 kHz 33 mA až 200 mA CMC 0,036 % + 20 µA 5 kHz až 10 kHz 33 mA až 200 mA CMC 0,20 % + 100 µA 10 kHz až 30 kHz 33 mA až 200 mA CMC 0,40 % + 200 µA 10 Hz až 45 Hz 200 mA až 330 mA CMC 0,053 % + 200 µA 45 Hz až 1 kHz 200 mA až 330 mA CMC 0,040 % + 20 µA 1 kHz až 5 kHz 200 mA až 330 mA CMC 0,10 % + 50 µA 5 kHz až 10 kHz 200 mA až 330 mA CMC 0,20 % + 100 µA 10 kHz až 30 kHz 200 mA až 330 mA CMC 0,40 % + 200 µA 10 Hz až 45 Hz 330 mA až 1,1 A CMC 0,053 % + 200 µA 45 Hz až 1 kHz 330 mA až 1,1 A CMC 0,050 % + 100 µA 1 kHz až 5 kHz 330 mA až 1,1 A CMC 0,069 % + 320 µA 10 Hz až 45 Hz 1,1 A až 2 A CMC 0,053 % + 200 µA 45 Hz až 1 kHz 1,1 A až 2 A CMC 0,060 % + 100 µA 1 kHz až 5 kHz 1,1 A až 2 A CMC 0,069 % + 320 µA MK4, MK8, MK9, MK11 Prad przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badan instalacji, zrodla i kalibratory pradu Wzorcowanie – wielkosci elektryczne Multimetr lub kalibrator wzorcowy: porownanie lub pomiar bezposredni 10 Hz do 5 kHz od 9 µA do 29 µA CMC 0,040 % + 20 nA 10 Hz do 5 kHz od 29 µA do 200 µA CMC 0,040 % + 20 nA 5 kHz do 10 kHz od 29 µA do 200 µA CMC 0,80 % + 200 nA 10 Hz do 5 kHz od 200 µA do 330 µA CMC 0,033 % + 200 nA 5 kHz do 10 kHz od 200 µA do 330 µA CMC 0,80 % + 200 nA 10 Hz do 5 kHz od 330 µA do 2 mA CMC 0,033 % + 200 nA 5 kHz do 10 kHz od 330 µA do 2 mA CMC 0,50 % + 300 nA 10 Hz do 5 kHz od 2 mA do 3,3 mA CMC 0,036 % + 2 µA 5 kHz do 10 kHz od 2 mA do 3,3 mA CMC 0,50 % + 300 nA 10 Hz do 5 kHz od 3,3 mA do 20 mA CMC 0,036 % + 2 µA 5 kHz do 10 kHz od 3,3 mA do 20 mA CMC 0,20 % + 3 µA 10 kHz do 30 kHz od 3,3 mA do 20 mA CMC 0,40 % + 4 µA 10 Hz do 45 Hz od 20 mA do 33 mA CMC 0,036 % + 20 µA 45 Hz do 1 kHz od 20 mA do 33 mA CMC 0,040 % + 2 µA 1 kHz do 5 kHz od 20 mA do 33 mA CMC 0,080 % + 2 µA 5 kHz do 10 kHz od 20 mA do 33 mA CMC 0,20 % + 3 µA 10 kHz do 30 kHz od 20 mA do 33 mA CMC 0,40 % + 4 µA 10 Hz do 5 kHz od 33 mA do 200 mA CMC 0,036 % + 20 µA 5 kHz do 10 kHz od 33 mA do 200 mA CMC 0,20 % + 100 µA 10 kHz do 30 kHz od 33 mA do 200 mA CMC 0,40 % + 200 µA 10 Hz do 45 Hz od 200 mA do 330 mA CMC 0,053 % + 200 µA 45 Hz do 1 kHz od 200 mA do 330 mA CMC 0,040 % + 20 µA 1 kHz do 5 kHz od 200 mA do 330 mA CMC 0,10 % + 50 µA 5 kHz do 10 kHz od 200 mA do 330 mA CMC 0,20 % + 100 µA 10 kHz do 30 kHz od 200 mA do 330 mA CMC 0,40 % + 200 µA 10 Hz do 45 Hz od 330 mA do 1,1 A CMC 0,053 % + 200 µA 45 Hz do 1 kHz od 330 mA do 1,1 A CMC 0,050 % + 100 µA 1 kHz do 5 kHz od 330 mA do 1,1 A CMC 0,069 % + 320 µA 10 Hz do 45 Hz od 1,1 A do 2 A CMC 0,053 % + 200 µA 45 Hz do 1 kHz od 1,1 A do 2 A CMC 0,060 % + 100 µA 1 kHz do 5 kHz od 1,1 A do 2 A CMC 0,069 % + 320 µA Stridavy proud / Multimetry, ampermetry, testery, prevodniky, revizni pristroje, zdroje a kalibratory proudu Kalibrace – elektricke veliciny Etalonovy multimetr nebo kalibrator: porovnani nebo prime mereni 10 Hz az 5 kHz 9 µA az 29 µA CMC 0,040 % + 20 nA 10 Hz az 5 kHz 29 µA az 200 µA CMC 0,040 % + 20 nA 5 kHz az 10 kHz 29 µA az 200 µA CMC 0,80 % + 200 nA 10 Hz az 5 kHz 200 µA az 330 µA CMC 0,033 % + 200 nA 5 kHz az 10 kHz 200 µA az 330 µA CMC 0,80 % + 200 nA 10 Hz az 5 kHz 330 µA az 2 mA CMC 0,033 % + 200 nA 5 kHz az 10 kHz 330 µA az 2 mA CMC 0,50 % + 300 nA 10 Hz az 5 kHz 2 mA az 3,3 mA CMC 0,036 % + 2 µA 5 kHz az 10 kHz 2 mA az 3,3 mA CMC 0,50 % + 300 nA 10 Hz az 5 kHz 3,3 mA az 20 mA CMC 0,036 % + 2 µA 5 kHz az 10 kHz 3,3 mA az 20 mA CMC 0,20 % + 3 µA 10 kHz az 30 kHz 3,3 mA az 20 mA CMC 0,40 % + 4 µA 10 Hz az 45 Hz 20 mA az 33 mA CMC 0,036 % + 20 µA 45 Hz az 1 kHz 20 mA az 33 mA CMC 0,040 % + 2 µA 1 kHz az 5 kHz 20 mA az 33 mA CMC 0,080 % + 2 µA 5 kHz az 10 kHz 20 mA az 33 mA CMC 0,20 % + 3 µA 10 kHz az 30 kHz 20 mA az 33 mA CMC 0,40 % + 4 µA 10 Hz az 5 kHz 33 mA az 200 mA CMC 0,036 % + 20 µA 5 kHz az 10 kHz 33 mA az 200 mA CMC 0,20 % + 100 µA 10 kHz az 30 kHz 33 mA az 200 mA CMC 0,40 % + 200 µA 10 Hz az 45 Hz 200 mA az 330 mA CMC 0,053 % + 200 µA 45 Hz az 1 kHz 200 mA az 330 mA CMC 0,040 % + 20 µA 1 kHz az 5 kHz 200 mA az 330 mA CMC 0,10 % + 50 µA 5 kHz az 10 kHz 200 mA az 330 mA CMC 0,20 % + 100 µA 10 kHz az 30 kHz 200 mA az 330 mA CMC 0,40 % + 200 µA 10 Hz az 45 Hz 330 mA az 1,1 A CMC 0,053 % + 200 µA 45 Hz az 1 kHz 330 mA az 1,1 A CMC 0,050 % + 100 µA 1 kHz az 5 kHz 330 mA az 1,1 A CMC 0,069 % + 320 µA 10 Hz az 45 Hz 1,1 A az 2 A CMC 0,053 % + 200 µA 45 Hz az 1 kHz 1,1 A az 2 A CMC 0,060 % + 100 µA 1 kHz az 5 kHz 1,1 A az 2 A CMC 0,069 % + 320 µA MK4, MK8, MK9, MK11","search_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators Calibration – electrical quantities Standard multimeter or calibrator: comparison or direct measurement 10 Hz to 5 kHz 9 µA to 29 µA CMC 0,040 % + 20 nA 10 Hz to 5 kHz 29 µA to 200 µA CMC 0,040 % + 20 nA 5 kHz to 10 kHz 29 µA to 200 µA CMC 0,80 % + 200 nA 10 Hz to 5 kHz 200 µA to 330 µA CMC 0,033 % + 200 nA 5 kHz to 10 kHz 200 µA to 330 µA CMC 0,80 % + 200 nA 10 Hz to 5 kHz 330 µA to 2 mA CMC 0,033 % + 200 nA 5 kHz to 10 kHz 330 µA to 2 mA CMC 0,50 % + 300 nA 10 Hz to 5 kHz 2 mA to 3,3 mA CMC 0,036 % + 2 µA 5 kHz to 10 kHz 2 mA to 3,3 mA CMC 0,50 % + 300 nA 10 Hz to 5 kHz 3,3 mA to 20 mA CMC 0,036 % + 2 µA 5 kHz to 10 kHz 3,3 mA to 20 mA CMC 0,20 % + 3 µA 10 kHz to 30 kHz 3,3 mA to 20 mA CMC 0,40 % + 4 µA 10 Hz to 45 Hz 20 mA to 33 mA CMC 0,036 % + 20 µA 45 Hz to 1 kHz 20 mA to 33 mA CMC 0,040 % + 2 µA 1 kHz to 5 kHz 20 mA to 33 mA CMC 0,080 % + 2 µA 5 kHz to 10 kHz 20 mA to 33 mA CMC 0,20 % + 3 µA 10 kHz to 30 kHz 20 mA to 33 mA CMC 0,40 % + 4 µA 10 Hz to 5 kHz 33 mA to 200 mA CMC 0,036 % + 20 µA 5 kHz to 10 kHz 33 mA to 200 mA CMC 0,20 % + 100 µA 10 kHz to 30 kHz 33 mA to 200 mA CMC 0,40 % + 200 µA 10 Hz to 45 Hz 200 mA to 330 mA CMC 0,053 % + 200 µA 45 Hz to 1 kHz 200 mA to 330 mA CMC 0,040 % + 20 µA 1 kHz to 5 kHz 200 mA to 330 mA CMC 0,10 % + 50 µA 5 kHz to 10 kHz 200 mA to 330 mA CMC 0,20 % + 100 µA 10 kHz to 30 kHz 200 mA to 330 mA CMC 0,40 % + 200 µA 10 Hz to 45 Hz 330 mA to 1,1 A CMC 0,053 % + 200 µA 45 Hz to 1 kHz 330 mA to 1,1 A CMC 0,050 % + 100 µA 1 kHz to 5 kHz 330 mA to 1,1 A CMC 0,069 % + 320 µA 10 Hz to 45 Hz 1,1 A to 2 A CMC 0,053 % + 200 µA 45 Hz to 1 kHz 1,1 A to 2 A CMC 0,060 % + 100 µA 1 kHz to 5 kHz 1,1 A to 2 A CMC 0,069 % + 320 µA MK4, MK8, MK9, MK11","search_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器 校准 – 电学量 标准万用表或校准器：比较或直接测量 10 Hz 至 5 kHz 9 µA 至 29 µA CMC 0,040 % + 20 nA 10 Hz 至 5 kHz 29 µA 至 200 µA CMC 0,040 % + 20 nA 5 kHz 至 10 kHz 29 µA 至 200 µA CMC 0,80 % + 200 nA 10 Hz 至 5 kHz 200 µA 至 330 µA CMC 0,033 % + 200 nA 5 kHz 至 10 kHz 200 µA 至 330 µA CMC 0,80 % + 200 nA 10 Hz 至 5 kHz 330 µA 至 2 mA CMC 0,033 % + 200 nA 5 kHz 至 10 kHz 330 µA 至 2 mA CMC 0,50 % + 300 nA 10 Hz 至 5 kHz 2 mA 至 3,3 mA CMC 0,036 % + 2 µA 5 kHz 至 10 kHz 2 mA 至 3,3 mA CMC 0,50 % + 300 nA 10 Hz 至 5 kHz 3,3 mA 至 20 mA CMC 0,036 % + 2 µA 5 kHz 至 10 kHz 3,3 mA 至 20 mA CMC 0,20 % + 3 µA 10 kHz 至 30 kHz 3,3 mA 至 20 mA CMC 0,40 % + 4 µA 10 Hz 至 45 Hz 20 mA 至 33 mA CMC 0,036 % + 20 µA 45 Hz 至 1 kHz 20 mA 至 33 mA CMC 0,040 % + 2 µA 1 kHz 至 5 kHz 20 mA 至 33 mA CMC 0,080 % + 2 µA 5 kHz 至 10 kHz 20 mA 至 33 mA CMC 0,20 % + 3 µA 10 kHz 至 30 kHz 20 mA 至 33 mA CMC 0,40 % + 4 µA 10 Hz 至 5 kHz 33 mA 至 200 mA CMC 0,036 % + 20 µA 5 kHz 至 10 kHz 33 mA 至 200 mA CMC 0,20 % + 100 µA 10 kHz 至 30 kHz 33 mA 至 200 mA CMC 0,40 % + 200 µA 10 Hz 至 45 Hz 200 mA 至 330 mA CMC 0,053 % + 200 µA 45 Hz 至 1 kHz 200 mA 至 330 mA CMC 0,040 % + 20 µA 1 kHz 至 5 kHz 200 mA 至 330 mA CMC 0,10 % + 50 µA 5 kHz 至 10 kHz 200 mA 至 330 mA CMC 0,20 % + 100 µA 10 kHz 至 30 kHz 200 mA 至 330 mA CMC 0,40 % + 200 µA 10 Hz 至 45 Hz 330 mA 至 1,1 A CMC 0,053 % + 200 µA 45 Hz 至 1 kHz 330 mA 至 1,1 A CMC 0,050 % + 100 µA 1 kHz 至 5 kHz 330 mA 至 1,1 A CMC 0,069 % + 320 µA 10 Hz 至 45 Hz 1,1 A 至 2 A CMC 0,053 % + 200 µA 45 Hz 至 1 kHz 1,1 A 至 2 A CMC 0,060 % + 100 µA 1 kHz 至 5 kHz 1,1 A 至 2 A CMC 0,069 % + 320 µA MK4, MK8, MK9, MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"11e90995fb6e5ad1f8dadfd5","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu","test_object_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators","test_object_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器","test_object_cs":"Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 1 kHz","range":"od 2 A do 3 A","cmc":"0,060 %"},{"name":"1 kHz do 5 kHz","range":"od 2 A do 3 A","cmc":"0,10 %"},{"name":"45 Hz do 1 kHz","range":"od 3 A do 11 A","cmc":"0,050 %"},{"name":"1 kHz do 5 kHz","range":"od 3 A do 11 A","cmc":"0,10 %"}],"parameters_en":[{"name":"10 Hz to 1 kHz","range":"2 A to 3 A","cmc":"0,060 %"},{"name":"1 kHz to 5 kHz","range":"2 A to 3 A","cmc":"0,10 %"},{"name":"45 Hz to 1 kHz","range":"3 A to 11 A","cmc":"0,050 %"},{"name":"1 kHz to 5 kHz","range":"3 A to 11 A","cmc":"0,10 %"}],"parameters_zh":[{"name":"10 Hz 至 1 kHz","range":"2 A 至 3 A","cmc":"0,060 %"},{"name":"1 kHz 至 5 kHz","range":"2 A 至 3 A","cmc":"0,10 %"},{"name":"45 Hz 至 1 kHz","range":"3 A 至 11 A","cmc":"0,050 %"},{"name":"1 kHz 至 5 kHz","range":"3 A 至 11 A","cmc":"0,10 %"}],"parameters_cs":[{"name":"10 Hz až 1 kHz","range":"2 A až 3 A","cmc":"0,060 %"},{"name":"1 kHz až 5 kHz","range":"2 A až 3 A","cmc":"0,10 %"},{"name":"45 Hz až 1 kHz","range":"3 A až 11 A","cmc":"0,050 %"},{"name":"1 kHz až 5 kHz","range":"3 A až 11 A","cmc":"0,10 %"}],"technique":"Multimetr wzorcowy z bocznikiem: porównanie z wzorcem lub pomiar bezpośredni","technique_en":"Standard multimeter with a shunt: comparison with a standard or direct measurement","technique_zh":"带分流器的标准万用表：与标准比较或直接测量","technique_cs":"Etalonový multimetr s bočníkem: porovnání s etalonem nebo přímé měření","techniques":["Multimetr wzorcowy z bocznikiem: porównanie z wzorcem lub pomiar bezpośredni"],"techniques_en":["Standard multimeter with a shunt: comparison with a standard or direct measurement"],"techniques_zh":["带分流器的标准万用表：与标准比较或直接测量"],"techniques_cs":["Etalonový multimetr s bočníkem: porovnání s etalonem nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 1 kHz od 2 A do 3 A CMC 0,060 %\n1 kHz do 5 kHz od 2 A do 3 A CMC 0,10 %\n45 Hz do 1 kHz od 3 A do 11 A CMC 0,050 %\n1 kHz do 5 kHz od 3 A do 11 A CMC 0,10 %\nMultimetr wzorcowy z bocznikiem: porównanie z wzorcem lub pomiar bezpośredni","reference":"MK4, MK8, MK9, MK11","norm_bases":["MK4","MK8","MK9","MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu Wzorcowanie – wielkości elektryczne Multimetr wzorcowy z bocznikiem: porównanie z wzorcem lub pomiar bezpośredni 10 Hz do 1 kHz od 2 A do 3 A CMC 0,060 % 1 kHz do 5 kHz od 2 A do 3 A CMC 0,10 % 45 Hz do 1 kHz od 3 A do 11 A CMC 0,050 % 1 kHz do 5 kHz od 3 A do 11 A CMC 0,10 % Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu Kalibrace – elektrické veličiny Etalonový multimetr s bočníkem: porovnání s etalonem nebo přímé měření 10 Hz až 1 kHz 2 A až 3 A CMC 0,060 % 1 kHz až 5 kHz 2 A až 3 A CMC 0,10 % 45 Hz až 1 kHz 3 A až 11 A CMC 0,050 % 1 kHz až 5 kHz 3 A až 11 A CMC 0,10 % MK4, MK8, MK9, MK11 Prad przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badan instalacji, zrodla i kalibratory pradu Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy z bocznikiem: porownanie z wzorcem lub pomiar bezposredni 10 Hz do 1 kHz od 2 A do 3 A CMC 0,060 % 1 kHz do 5 kHz od 2 A do 3 A CMC 0,10 % 45 Hz do 1 kHz od 3 A do 11 A CMC 0,050 % 1 kHz do 5 kHz od 3 A do 11 A CMC 0,10 % Stridavy proud / Multimetry, ampermetry, testery, prevodniky, revizni pristroje, zdroje a kalibratory proudu Kalibrace – elektricke veliciny Etalonovy multimetr s bocnikem: porovnani s etalonem nebo prime mereni 10 Hz az 1 kHz 2 A az 3 A CMC 0,060 % 1 kHz az 5 kHz 2 A az 3 A CMC 0,10 % 45 Hz az 1 kHz 3 A az 11 A CMC 0,050 % 1 kHz az 5 kHz 3 A az 11 A CMC 0,10 % MK4, MK8, MK9, MK11","search_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators Calibration – electrical quantities Standard multimeter with a shunt: comparison with a standard or direct measurement 10 Hz to 1 kHz 2 A to 3 A CMC 0,060 % 1 kHz to 5 kHz 2 A to 3 A CMC 0,10 % 45 Hz to 1 kHz 3 A to 11 A CMC 0,050 % 1 kHz to 5 kHz 3 A to 11 A CMC 0,10 % MK4, MK8, MK9, MK11","search_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器 校准 – 电学量 带分流器的标准万用表：与标准比较或直接测量 10 Hz 至 1 kHz 2 A 至 3 A CMC 0,060 % 1 kHz 至 5 kHz 2 A 至 3 A CMC 0,10 % 45 Hz 至 1 kHz 3 A 至 11 A CMC 0,050 % 1 kHz 至 5 kHz 3 A 至 11 A CMC 0,10 % MK4, MK8, MK9, MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a22178602deb3f6d5241c9fb","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu","test_object_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators","test_object_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器","test_object_cs":"Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 11 A do 20,5 A","cmc":"0,070 %"},{"name":"45 Hz do 65 Hz","range":"od 20,5 A do 105 A","cmc":"0,070 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"11 A to 20,5 A","cmc":"0,070 %"},{"name":"45 Hz to 65 Hz","range":"20,5 A to 105 A","cmc":"0,070 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"11 A 至 20,5 A","cmc":"0,070 %"},{"name":"45 Hz 至 65 Hz","range":"20,5 A 至 105 A","cmc":"0,070 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"11 A až 20,5 A","cmc":"0,070 %"},{"name":"45 Hz až 65 Hz","range":"20,5 A až 105 A","cmc":"0,070 %"}],"technique":"Multimetr wzorcowy z przekładnikiem prądowym: porównanie z wzorcem lub pomiar bezpośredni","technique_en":"Standard multimeter with a current transformer: comparison with a standard or direct measurement","technique_zh":"带电流互感器的标准万用表：与标准比较或直接测量","technique_cs":"Etalonový multimetr s proudovým transformátorem: porovnání s etalonem nebo přímé měření","techniques":["Multimetr wzorcowy z przekładnikiem prądowym: porównanie z wzorcem lub pomiar bezpośredni"],"techniques_en":["Standard multimeter with a current transformer: comparison with a standard or direct measurement"],"techniques_zh":["带电流互感器的标准万用表：与标准比较或直接测量"],"techniques_cs":["Etalonový multimetr s proudovým transformátorem: porovnání s etalonem nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 65 Hz od 11 A do 20,5 A CMC 0,070 %\n45 Hz do 65 Hz od 20,5 A do 105 A CMC 0,070 %\nMultimetr wzorcowy z przekładnikiem prądowym: porównanie z wzorcem lub pomiar bezpośredni","reference":"MK4, MK8, MK9, MK11","norm_bases":["MK4","MK8","MK9","MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu Wzorcowanie – wielkości elektryczne Multimetr wzorcowy z przekładnikiem prądowym: porównanie z wzorcem lub pomiar bezpośredni 45 Hz do 65 Hz od 11 A do 20,5 A CMC 0,070 % 45 Hz do 65 Hz od 20,5 A do 105 A CMC 0,070 % Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu Kalibrace – elektrické veličiny Etalonový multimetr s proudovým transformátorem: porovnání s etalonem nebo přímé měření 45 Hz až 65 Hz 11 A až 20,5 A CMC 0,070 % 45 Hz až 65 Hz 20,5 A až 105 A CMC 0,070 % MK4, MK8, MK9, MK11 Prad przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badan instalacji, zrodla i kalibratory pradu Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy z przekladnikiem pradowym: porownanie z wzorcem lub pomiar bezposredni 45 Hz do 65 Hz od 11 A do 20,5 A CMC 0,070 % 45 Hz do 65 Hz od 20,5 A do 105 A CMC 0,070 % Stridavy proud / Multimetry, ampermetry, testery, prevodniky, revizni pristroje, zdroje a kalibratory proudu Kalibrace – elektricke veliciny Etalonovy multimetr s proudovym transformatorem: porovnani s etalonem nebo prime mereni 45 Hz az 65 Hz 11 A az 20,5 A CMC 0,070 % 45 Hz az 65 Hz 20,5 A az 105 A CMC 0,070 % MK4, MK8, MK9, MK11","search_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators Calibration – electrical quantities Standard multimeter with a current transformer: comparison with a standard or direct measurement 45 Hz to 65 Hz 11 A to 20,5 A CMC 0,070 % 45 Hz to 65 Hz 20,5 A to 105 A CMC 0,070 % MK4, MK8, MK9, MK11","search_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器 校准 – 电学量 带电流互感器的标准万用表：与标准比较或直接测量 45 Hz 至 65 Hz 11 A 至 20,5 A CMC 0,070 % 45 Hz 至 65 Hz 20,5 A 至 105 A CMC 0,070 % MK4, MK8, MK9, MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aa3df0040cc97273b391d455","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu","test_object_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators","test_object_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器","test_object_cs":"Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"65 Hz do 100 Hz","range":"od 11 A do 20,5 A","cmc":"0,12 % + 5 mA"},{"name":"100 Hz do 1 kHz","range":"od 11 A do 20,5 A","cmc":"0,15 % + 5 mA"}],"parameters_en":[{"name":"65 Hz to 100 Hz","range":"11 A to 20,5 A","cmc":"0,12 % + 5 mA"},{"name":"100 Hz to 1 kHz","range":"11 A to 20,5 A","cmc":"0,15 % + 5 mA"}],"parameters_zh":[{"name":"65 Hz 至 100 Hz","range":"11 A 至 20,5 A","cmc":"0,12 % + 5 mA"},{"name":"100 Hz 至 1 kHz","range":"11 A 至 20,5 A","cmc":"0,15 % + 5 mA"}],"parameters_cs":[{"name":"65 Hz až 100 Hz","range":"11 A až 20,5 A","cmc":"0,12 % + 5 mA"},{"name":"100 Hz až 1 kHz","range":"11 A až 20,5 A","cmc":"0,15 % + 5 mA"}],"technique":"Kalibrator wzorcowy: generowanie lub porównanie za pomocą multimetru","technique_en":"Standard calibrator: generation or comparison using a multimeter","technique_zh":"标准校准器：产生或借助万用表比较","technique_cs":"Etalonový kalibrátor: generování nebo porovnání pomocí multimetru","techniques":["Kalibrator wzorcowy: generowanie lub porównanie za pomocą multimetru"],"techniques_en":["Standard calibrator: generation or comparison using a multimeter"],"techniques_zh":["标准校准器：产生或借助万用表比较"],"techniques_cs":["Etalonový kalibrátor: generování nebo porovnání pomocí multimetru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n65 Hz do 100 Hz od 11 A do 20,5 A CMC 0,12 % + 5 mA\n100 Hz do 1 kHz od 11 A do 20,5 A CMC 0,15 % + 5 mA\nKalibrator wzorcowy: generowanie lub porównanie za pomocą multimetru","reference":"MK4, MK8, MK9, MK11","norm_bases":["MK4","MK8","MK9","MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badań instalacji, źródła i kalibratory prądu Wzorcowanie – wielkości elektryczne Kalibrator wzorcowy: generowanie lub porównanie za pomocą multimetru 65 Hz do 100 Hz od 11 A do 20,5 A CMC 0,12 % + 5 mA 100 Hz do 1 kHz od 11 A do 20,5 A CMC 0,15 % + 5 mA Střídavý proud / Multimetry, ampérmetry, testery, převodníky, revizní přístroje, zdroje a kalibrátory proudu Kalibrace – elektrické veličiny Etalonový kalibrátor: generování nebo porovnání pomocí multimetru 65 Hz až 100 Hz 11 A až 20,5 A CMC 0,12 % + 5 mA 100 Hz až 1 kHz 11 A až 20,5 A CMC 0,15 % + 5 mA MK4, MK8, MK9, MK11 Prad przemienny / multimetry, amperomierze, testery, przetworniki, mierniki do badan instalacji, zrodla i kalibratory pradu Wzorcowanie – wielkosci elektryczne Kalibrator wzorcowy: generowanie lub porownanie za pomoca multimetru 65 Hz do 100 Hz od 11 A do 20,5 A CMC 0,12 % + 5 mA 100 Hz do 1 kHz od 11 A do 20,5 A CMC 0,15 % + 5 mA Stridavy proud / Multimetry, ampermetry, testery, prevodniky, revizni pristroje, zdroje a kalibratory proudu Kalibrace – elektricke veliciny Etalonovy kalibrator: generovani nebo porovnani pomoci multimetru 65 Hz az 100 Hz 11 A az 20,5 A CMC 0,12 % + 5 mA 100 Hz az 1 kHz 11 A az 20,5 A CMC 0,15 % + 5 mA MK4, MK8, MK9, MK11","search_en":"AC current / Multimeters, ammeters, testers, transducers, installation testers, current sources and calibrators Calibration – electrical quantities Standard calibrator: generation or comparison using a multimeter 65 Hz to 100 Hz 11 A to 20,5 A CMC 0,12 % + 5 mA 100 Hz to 1 kHz 11 A to 20,5 A CMC 0,15 % + 5 mA MK4, MK8, MK9, MK11","search_zh":"交流电流 / 万用表、电流表、测试仪、变送器、电气安装测试仪、电流源和校准器 校准 – 电学量 标准校准器：产生或借助万用表比较 65 Hz 至 100 Hz 11 A 至 20,5 A CMC 0,12 % + 5 mA 100 Hz 至 1 kHz 11 A 至 20,5 A CMC 0,15 % + 5 mA MK4, MK8, MK9, MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2502bb732dd27ef9e5021938","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / źródła prądu","test_object_en":"AC current / Current sources","test_object_zh":"交流电流 / 电流源","test_object_cs":"Střídavý proud / Zdroje proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 105 A do 4000 A","cmc":"1,5 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"105 A to 4000 A","cmc":"1,5 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"105 A 至 4000 A","cmc":"1,5 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"105 A až 4000 A","cmc":"1,5 %"}],"technique":"Pomiar multimetrem wzorcowym z cęgami prądowymi","technique_en":"Measurement by a standard multimeter with current clamps","technique_zh":"用带电流钳的标准万用表测量","technique_cs":"Měření etalonovým multimetrem s proudovými kleštěmi","techniques":["Pomiar multimetrem wzorcowym z cęgami prądowymi"],"techniques_en":["Measurement by a standard multimeter with current clamps"],"techniques_zh":["用带电流钳的标准万用表测量"],"techniques_cs":["Měření etalonovým multimetrem s proudovými kleštěmi"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n45 Hz do 65 Hz od 105 A do 4000 A CMC 1,5 %\nPomiar multimetrem wzorcowym z cęgami prądowymi","reference":"MK9","norm_bases":["MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu Wzorcowanie – wielkości elektryczne Pomiar multimetrem wzorcowym z cęgami prądowymi 45 Hz do 65 Hz od 105 A do 4000 A CMC 1,5 % Střídavý proud / Zdroje proudu Kalibrace – elektrické veličiny Měření etalonovým multimetrem s proudovými kleštěmi 45 Hz až 65 Hz 105 A až 4000 A CMC 1,5 % MK9 Prad przemienny / zrodla pradu Wzorcowanie – wielkosci elektryczne Pomiar multimetrem wzorcowym z cegami pradowymi 45 Hz do 65 Hz od 105 A do 4000 A CMC 1,5 % Stridavy proud / Zdroje proudu Kalibrace – elektricke veliciny Mereni etalonovym multimetrem s proudovymi klestemi 45 Hz az 65 Hz 105 A az 4000 A CMC 1,5 % MK9","search_en":"AC current / Current sources Calibration – electrical quantities Measurement by a standard multimeter with current clamps 45 Hz to 65 Hz 105 A to 4000 A CMC 1,5 % MK9","search_zh":"交流电流 / 电流源 校准 – 电学量 用带电流钳的标准万用表测量 45 Hz 至 65 Hz 105 A 至 4000 A CMC 1,5 % MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1dfba514bf4dc3e04ac28985","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / multimetry cęgowe","test_object_en":"AC current / Clamp multimeters","test_object_zh":"交流电流 / 钳形万用表","test_object_cs":"Střídavý proud / Klešťové multimetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 1 A do 105 A","cmc":"0,25 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"1 A to 105 A","cmc":"0,25 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"1 A 至 105 A","cmc":"0,25 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"1 A až 105 A","cmc":"0,25 %"}],"technique":"Generowanie kalibratorem wzorcowym do przewodu prostego","technique_en":"Generation by a standard calibrator into a straight conductor","technique_zh":"用标准校准器向直导线产生电流","technique_cs":"Generování etalonovým kalibrátorem do přímého vodiče","techniques":["Generowanie kalibratorem wzorcowym do przewodu prostego"],"techniques_en":["Generation by a standard calibrator into a straight conductor"],"techniques_zh":["用标准校准器向直导线产生电流"],"techniques_cs":["Generování etalonovým kalibrátorem do přímého vodiče"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n45 Hz do 65 Hz od 1 A do 105 A CMC 0,25 %\nGenerowanie kalibratorem wzorcowym do przewodu prostego","reference":"MK4, MK8","norm_bases":["MK4","MK8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / multimetry cęgowe Wzorcowanie – wielkości elektryczne Generowanie kalibratorem wzorcowym do przewodu prostego 45 Hz do 65 Hz od 1 A do 105 A CMC 0,25 % Střídavý proud / Klešťové multimetry Kalibrace – elektrické veličiny Generování etalonovým kalibrátorem do přímého vodiče 45 Hz až 65 Hz 1 A až 105 A CMC 0,25 % MK4, MK8 Prad przemienny / multimetry cegowe Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem wzorcowym do przewodu prostego 45 Hz do 65 Hz od 1 A do 105 A CMC 0,25 % Stridavy proud / Klestove multimetry Kalibrace – elektricke veliciny Generovani etalonovym kalibratorem do primeho vodice 45 Hz az 65 Hz 1 A az 105 A CMC 0,25 % MK4, MK8","search_en":"AC current / Clamp multimeters Calibration – electrical quantities Generation by a standard calibrator into a straight conductor 45 Hz to 65 Hz 1 A to 105 A CMC 0,25 % MK4, MK8","search_zh":"交流电流 / 钳形万用表 校准 – 电学量 用标准校准器向直导线产生电流 45 Hz 至 65 Hz 1 A 至 105 A CMC 0,25 % MK4, MK8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a54c9fffa544af43ed2c5eab","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / multimetry cęgowe","test_object_en":"AC current / Clamp multimeters","test_object_zh":"交流电流 / 钳形万用表","test_object_cs":"Střídavý proud / Klešťové multimetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 105 A do 1050 A","cmc":"1,5 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"105 A to 1050 A","cmc":"1,5 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"105 A 至 1050 A","cmc":"1,5 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"105 A až 1050 A","cmc":"1,5 %"}],"technique":"Generowanie kalibratorem wzorcowym do cewki dziesięciozwojowej","technique_en":"Generation by a standard calibrator into a ten-turn coil","technique_zh":"用标准校准器向十匝线圈产生电流","technique_cs":"Generování etalonovým kalibrátorem do desetizávitové cívky","techniques":["Generowanie kalibratorem wzorcowym do cewki dziesięciozwojowej"],"techniques_en":["Generation by a standard calibrator into a ten-turn coil"],"techniques_zh":["用标准校准器向十匝线圈产生电流"],"techniques_cs":["Generování etalonovým kalibrátorem do desetizávitové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n45 Hz do 65 Hz od 105 A do 1050 A CMC 1,5 %\nGenerowanie kalibratorem wzorcowym do cewki dziesięciozwojowej","reference":"MK4, MK8","norm_bases":["MK4","MK8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / multimetry cęgowe Wzorcowanie – wielkości elektryczne Generowanie kalibratorem wzorcowym do cewki dziesięciozwojowej 45 Hz do 65 Hz od 105 A do 1050 A CMC 1,5 % Střídavý proud / Klešťové multimetry Kalibrace – elektrické veličiny Generování etalonovým kalibrátorem do desetizávitové cívky 45 Hz až 65 Hz 105 A až 1050 A CMC 1,5 % MK4, MK8 Prad przemienny / multimetry cegowe Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem wzorcowym do cewki dziesieciozwojowej 45 Hz do 65 Hz od 105 A do 1050 A CMC 1,5 % Stridavy proud / Klestove multimetry Kalibrace – elektricke veliciny Generovani etalonovym kalibratorem do desetizavitove civky 45 Hz az 65 Hz 105 A az 1050 A CMC 1,5 % MK4, MK8","search_en":"AC current / Clamp multimeters Calibration – electrical quantities Generation by a standard calibrator into a ten-turn coil 45 Hz to 65 Hz 105 A to 1050 A CMC 1,5 % MK4, MK8","search_zh":"交流电流 / 钳形万用表 校准 – 电学量 用标准校准器向十匝线圈产生电流 45 Hz 至 65 Hz 105 A 至 1050 A CMC 1,5 % MK4, MK8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b805aa87ef7cc89c2daad2e","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"8","test_object":"Składowe harmoniczne prądu / analizatory sieci zasilającej, mierniki do badań instalacji, źródła zasilania przemiennego / harmoniczna podstawowa: 45 Hz do 65 Hz","test_object_en":"Current harmonic components / Power network analysers, installation testers, AC power sources / Fundamental: 45 Hz to 65 Hz","test_object_zh":"电流谐波分量 / 电网分析仪、电气安装测试仪、交流电源 / 基波：45 Hz 至 65 Hz","test_object_cs":"Harmonické složky proudu / Analyzátory napájecí sítě, revizní přístroje, střídavé napájecí zdroje / Základní harmonická: 45 Hz až 65 Hz","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"prąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 45 Hz do 900 Hz","range":"od 33 µA do 330 mA","cmc":"0,10 % + 0,10 mA"},{"name":"prąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 900 Hz do 2 kHz","range":"od 33 µA do 165 mA","cmc":"0,10 % + 0,10 mA"},{"name":"prąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 2 kHz do 5 kHz","range":"od 33 µA do 99 mA","cmc":"0,10 % + 0,10 mA"},{"name":"prąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 45 Hz do 900 Hz","range":"od 330 µA do 3 A","cmc":"0,10 % + 1,0 mA"},{"name":"prąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 900 Hz do 2 kHz","range":"od 330 µA do 0,60 A","cmc":"0,10 % + 1,0 mA"},{"name":"prąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 2 kHz do 5 kHz","range":"od 330 µA do 0,60 A","cmc":"0,20 % + 1,3 mA"},{"name":"prąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 45 Hz do 900 Hz","range":"od 3 mA do 20,5 A","cmc":"0,10 % + 10 mA"},{"name":"prąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 900 Hz do 2 kHz","range":"od 3 mA do 4,1 A","cmc":"0,10 % + 10 mA"},{"name":"prąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 2 kHz do 5 kHz","range":"od 3 mA do 4,1 A","cmc":"0,20 % + 10 mA"}],"parameters_en":[{"name":"composite current 33 mA to 0,33 A; harmonic frequency 45 Hz to 900 Hz","range":"33 µA to 330 mA","cmc":"0,10 % + 0,10 mA"},{"name":"composite current 33 mA to 0,33 A; harmonic frequency 900 Hz to 2 kHz","range":"33 µA to 165 mA","cmc":"0,10 % + 0,10 mA"},{"name":"composite current 33 mA to 0,33 A; harmonic frequency 2 kHz to 5 kHz","range":"33 µA to 99 mA","cmc":"0,10 % + 0,10 mA"},{"name":"composite current 0,33 A to 3 A; harmonic frequency 45 Hz to 900 Hz","range":"330 µA to 3 A","cmc":"0,10 % + 1,0 mA"},{"name":"composite current 0,33 A to 3 A; harmonic frequency 900 Hz to 2 kHz","range":"330 µA to 0,60 A","cmc":"0,10 % + 1,0 mA"},{"name":"composite current 0,33 A to 3 A; harmonic frequency 2 kHz to 5 kHz","range":"330 µA to 0,60 A","cmc":"0,20 % + 1,3 mA"},{"name":"composite current 3 A to 20,5 A; harmonic frequency 45 Hz to 900 Hz","range":"3 mA to 20,5 A","cmc":"0,10 % + 10 mA"},{"name":"composite current 3 A to 20,5 A; harmonic frequency 900 Hz to 2 kHz","range":"3 mA to 4,1 A","cmc":"0,10 % + 10 mA"},{"name":"composite current 3 A to 20,5 A; harmonic frequency 2 kHz to 5 kHz","range":"3 mA to 4,1 A","cmc":"0,20 % + 10 mA"}],"parameters_zh":[{"name":"合成电流 33 mA 至 0,33 A；谐波频率 45 Hz 至 900 Hz","range":"33 µA 至 330 mA","cmc":"0,10 % + 0,10 mA"},{"name":"合成电流 33 mA 至 0,33 A；谐波频率 900 Hz 至 2 kHz","range":"33 µA 至 165 mA","cmc":"0,10 % + 0,10 mA"},{"name":"合成电流 33 mA 至 0,33 A；谐波频率 2 kHz 至 5 kHz","range":"33 µA 至 99 mA","cmc":"0,10 % + 0,10 mA"},{"name":"合成电流 0,33 A 至 3 A；谐波频率 45 Hz 至 900 Hz","range":"330 µA 至 3 A","cmc":"0,10 % + 1,0 mA"},{"name":"合成电流 0,33 A 至 3 A；谐波频率 900 Hz 至 2 kHz","range":"330 µA 至 0,60 A","cmc":"0,10 % + 1,0 mA"},{"name":"合成电流 0,33 A 至 3 A；谐波频率 2 kHz 至 5 kHz","range":"330 µA 至 0,60 A","cmc":"0,20 % + 1,3 mA"},{"name":"合成电流 3 A 至 20,5 A；谐波频率 45 Hz 至 900 Hz","range":"3 mA 至 20,5 A","cmc":"0,10 % + 10 mA"},{"name":"合成电流 3 A 至 20,5 A；谐波频率 900 Hz 至 2 kHz","range":"3 mA 至 4,1 A","cmc":"0,10 % + 10 mA"},{"name":"合成电流 3 A 至 20,5 A；谐波频率 2 kHz 至 5 kHz","range":"3 mA 至 4,1 A","cmc":"0,20 % + 10 mA"}],"parameters_cs":[{"name":"složený proud 33 mA až 0,33 A; frekvence harmonické 45 Hz až 900 Hz","range":"33 µA až 330 mA","cmc":"0,10 % + 0,10 mA"},{"name":"složený proud 33 mA až 0,33 A; frekvence harmonické 900 Hz až 2 kHz","range":"33 µA až 165 mA","cmc":"0,10 % + 0,10 mA"},{"name":"složený proud 33 mA až 0,33 A; frekvence harmonické 2 kHz až 5 kHz","range":"33 µA až 99 mA","cmc":"0,10 % + 0,10 mA"},{"name":"složený proud 0,33 A až 3 A; frekvence harmonické 45 Hz až 900 Hz","range":"330 µA až 3 A","cmc":"0,10 % + 1,0 mA"},{"name":"složený proud 0,33 A až 3 A; frekvence harmonické 900 Hz až 2 kHz","range":"330 µA až 0,60 A","cmc":"0,10 % + 1,0 mA"},{"name":"složený proud 0,33 A až 3 A; frekvence harmonické 2 kHz až 5 kHz","range":"330 µA až 0,60 A","cmc":"0,20 % + 1,3 mA"},{"name":"složený proud 3 A až 20,5 A; frekvence harmonické 45 Hz až 900 Hz","range":"3 mA až 20,5 A","cmc":"0,10 % + 10 mA"},{"name":"složený proud 3 A až 20,5 A; frekvence harmonické 900 Hz až 2 kHz","range":"3 mA až 4,1 A","cmc":"0,10 % + 10 mA"},{"name":"složený proud 3 A až 20,5 A; frekvence harmonické 2 kHz až 5 kHz","range":"3 mA až 4,1 A","cmc":"0,20 % + 10 mA"}],"technique":"Bezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym","technique_en":"Direct generation by a standard calibrator or direct measurement by a standard analyser","technique_zh":"用标准校准器直接产生或用标准分析仪直接测量","technique_cs":"Přímé generování etalonovým kalibrátorem nebo přímé měření etalonovým analyzátorem","techniques":["Bezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym"],"techniques_en":["Direct generation by a standard calibrator or direct measurement by a standard analyser"],"techniques_zh":["用标准校准器直接产生或用标准分析仪直接测量"],"techniques_cs":["Přímé generování etalonovým kalibrátorem nebo přímé měření etalonovým analyzátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nprąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 45 Hz do 900 Hz od 33 µA do 330 mA CMC 0,10 % + 0,10 mA\nprąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 900 Hz do 2 kHz od 33 µA do 165 mA CMC 0,10 % + 0,10 mA\nprąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 2 kHz do 5 kHz od 33 µA do 99 mA CMC 0,10 % + 0,10 mA\nprąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 45 Hz do 900 Hz od 330 µA do 3 A CMC 0,10 % + 1,0 mA\nprąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 900 Hz do 2 kHz od 330 µA do 0,60 A CMC 0,10 % + 1,0 mA\nprąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 2 kHz do 5 kHz od 330 µA do 0,60 A CMC 0,20 % + 1,3 mA\nprąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 45 Hz do 900 Hz od 3 mA do 20,5 A CMC 0,10 % + 10 mA\nprąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 900 Hz do 2 kHz od 3 mA do 4,1 A CMC 0,10 % + 10 mA\nprąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 2 kHz do 5 kHz od 3 mA do 4,1 A CMC 0,20 % + 10 mA\nBezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym","reference":"MK9, MK11","norm_bases":["MK9","MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":"Względna składowa niepewności pomiaru odnosi się do harmonicznej podstawowej.","note_en":"The relative component of the measurement uncertainty refers to the fundamental harmonic.","note_zh":"测量不确定度的相对分量以基波为基准。","note_cs":"Relativní složka nejistoty měření je vztažena k základní harmonické.","search_text":"Składowe harmoniczne prądu / analizatory sieci zasilającej, mierniki do badań instalacji, źródła zasilania przemiennego / harmoniczna podstawowa: 45 Hz do 65 Hz Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem wzorcowym lub pomiar bezpośredni analizatorem wzorcowym prąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 45 Hz do 900 Hz od 33 µA do 330 mA CMC 0,10 % + 0,10 mA prąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 900 Hz do 2 kHz od 33 µA do 165 mA CMC 0,10 % + 0,10 mA prąd złożony 33 mA do 0,33 A; częstotliwość harmonicznej 2 kHz do 5 kHz od 33 µA do 99 mA CMC 0,10 % + 0,10 mA prąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 45 Hz do 900 Hz od 330 µA do 3 A CMC 0,10 % + 1,0 mA prąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 900 Hz do 2 kHz od 330 µA do 0,60 A CMC 0,10 % + 1,0 mA prąd złożony 0,33 A do 3 A; częstotliwość harmonicznej 2 kHz do 5 kHz od 330 µA do 0,60 A CMC 0,20 % + 1,3 mA prąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 45 Hz do 900 Hz od 3 mA do 20,5 A CMC 0,10 % + 10 mA prąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 900 Hz do 2 kHz od 3 mA do 4,1 A CMC 0,10 % + 10 mA prąd złożony 3 A do 20,5 A; częstotliwość harmonicznej 2 kHz do 5 kHz od 3 mA do 4,1 A CMC 0,20 % + 10 mA Harmonické složky proudu / Analyzátory napájecí sítě, revizní přístroje, střídavé napájecí zdroje / Základní harmonická: 45 Hz až 65 Hz Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem nebo přímé měření etalonovým analyzátorem složený proud 33 mA až 0,33 A; frekvence harmonické 45 Hz až 900 Hz 33 µA až 330 mA CMC 0,10 % + 0,10 mA složený proud 33 mA až 0,33 A; frekvence harmonické 900 Hz až 2 kHz 33 µA až 165 mA CMC 0,10 % + 0,10 mA složený proud 33 mA až 0,33 A; frekvence harmonické 2 kHz až 5 kHz 33 µA až 99 mA CMC 0,10 % + 0,10 mA složený proud 0,33 A až 3 A; frekvence harmonické 45 Hz až 900 Hz 330 µA až 3 A CMC 0,10 % + 1,0 mA složený proud 0,33 A až 3 A; frekvence harmonické 900 Hz až 2 kHz 330 µA až 0,60 A CMC 0,10 % + 1,0 mA složený proud 0,33 A až 3 A; frekvence harmonické 2 kHz až 5 kHz 330 µA až 0,60 A CMC 0,20 % + 1,3 mA složený proud 3 A až 20,5 A; frekvence harmonické 45 Hz až 900 Hz 3 mA až 20,5 A CMC 0,10 % + 10 mA složený proud 3 A až 20,5 A; frekvence harmonické 900 Hz až 2 kHz 3 mA až 4,1 A CMC 0,10 % + 10 mA složený proud 3 A až 20,5 A; frekvence harmonické 2 kHz až 5 kHz 3 mA až 4,1 A CMC 0,20 % + 10 mA MK9, MK11 Skladowe harmoniczne pradu / analizatory sieci zasilajacej, mierniki do badan instalacji, zrodla zasilania przemiennego / harmoniczna podstawowa: 45 Hz do 65 Hz Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem wzorcowym lub pomiar bezposredni analizatorem wzorcowym prad zlozony 33 mA do 0,33 A; czestotliwosc harmonicznej 45 Hz do 900 Hz od 33 µA do 330 mA CMC 0,10 % + 0,10 mA prad zlozony 33 mA do 0,33 A; czestotliwosc harmonicznej 900 Hz do 2 kHz od 33 µA do 165 mA CMC 0,10 % + 0,10 mA prad zlozony 33 mA do 0,33 A; czestotliwosc harmonicznej 2 kHz do 5 kHz od 33 µA do 99 mA CMC 0,10 % + 0,10 mA prad zlozony 0,33 A do 3 A; czestotliwosc harmonicznej 45 Hz do 900 Hz od 330 µA do 3 A CMC 0,10 % + 1,0 mA prad zlozony 0,33 A do 3 A; czestotliwosc harmonicznej 900 Hz do 2 kHz od 330 µA do 0,60 A CMC 0,10 % + 1,0 mA prad zlozony 0,33 A do 3 A; czestotliwosc harmonicznej 2 kHz do 5 kHz od 330 µA do 0,60 A CMC 0,20 % + 1,3 mA prad zlozony 3 A do 20,5 A; czestotliwosc harmonicznej 45 Hz do 900 Hz od 3 mA do 20,5 A CMC 0,10 % + 10 mA prad zlozony 3 A do 20,5 A; czestotliwosc harmonicznej 900 Hz do 2 kHz od 3 mA do 4,1 A CMC 0,10 % + 10 mA prad zlozony 3 A do 20,5 A; czestotliwosc harmonicznej 2 kHz do 5 kHz od 3 mA do 4,1 A CMC 0,20 % + 10 mA Harmonicke slozky proudu / Analyzatory napajeci site, revizni pristroje, stridave napajeci zdroje / Zakladni harmonicka: 45 Hz az 65 Hz Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem nebo prime mereni etalonovym analyzatorem slozeny proud 33 mA az 0,33 A; frekvence harmonicke 45 Hz az 900 Hz 33 µA az 330 mA CMC 0,10 % + 0,10 mA slozeny proud 33 mA az 0,33 A; frekvence harmonicke 900 Hz az 2 kHz 33 µA az 165 mA CMC 0,10 % + 0,10 mA slozeny proud 33 mA az 0,33 A; frekvence harmonicke 2 kHz az 5 kHz 33 µA az 99 mA CMC 0,10 % + 0,10 mA slozeny proud 0,33 A az 3 A; frekvence harmonicke 45 Hz az 900 Hz 330 µA az 3 A CMC 0,10 % + 1,0 mA slozeny proud 0,33 A az 3 A; frekvence harmonicke 900 Hz az 2 kHz 330 µA az 0,60 A CMC 0,10 % + 1,0 mA slozeny proud 0,33 A az 3 A; frekvence harmonicke 2 kHz az 5 kHz 330 µA az 0,60 A CMC 0,20 % + 1,3 mA slozeny proud 3 A az 20,5 A; frekvence harmonicke 45 Hz az 900 Hz 3 mA az 20,5 A CMC 0,10 % + 10 mA slozeny proud 3 A az 20,5 A; frekvence harmonicke 900 Hz az 2 kHz 3 mA az 4,1 A CMC 0,10 % + 10 mA slozeny proud 3 A az 20,5 A; frekvence harmonicke 2 kHz az 5 kHz 3 mA az 4,1 A CMC 0,20 % + 10 mA MK9, MK11","search_en":"Current harmonic components / Power network analysers, installation testers, AC power sources / Fundamental: 45 Hz to 65 Hz Calibration – electrical quantities Direct generation by a standard calibrator or direct measurement by a standard analyser composite current 33 mA to 0,33 A; harmonic frequency 45 Hz to 900 Hz 33 µA to 330 mA CMC 0,10 % + 0,10 mA composite current 33 mA to 0,33 A; harmonic frequency 900 Hz to 2 kHz 33 µA to 165 mA CMC 0,10 % + 0,10 mA composite current 33 mA to 0,33 A; harmonic frequency 2 kHz to 5 kHz 33 µA to 99 mA CMC 0,10 % + 0,10 mA composite current 0,33 A to 3 A; harmonic frequency 45 Hz to 900 Hz 330 µA to 3 A CMC 0,10 % + 1,0 mA composite current 0,33 A to 3 A; harmonic frequency 900 Hz to 2 kHz 330 µA to 0,60 A CMC 0,10 % + 1,0 mA composite current 0,33 A to 3 A; harmonic frequency 2 kHz to 5 kHz 330 µA to 0,60 A CMC 0,20 % + 1,3 mA composite current 3 A to 20,5 A; harmonic frequency 45 Hz to 900 Hz 3 mA to 20,5 A CMC 0,10 % + 10 mA composite current 3 A to 20,5 A; harmonic frequency 900 Hz to 2 kHz 3 mA to 4,1 A CMC 0,10 % + 10 mA composite current 3 A to 20,5 A; harmonic frequency 2 kHz to 5 kHz 3 mA to 4,1 A CMC 0,20 % + 10 mA MK9, MK11","search_zh":"电流谐波分量 / 电网分析仪、电气安装测试仪、交流电源 / 基波：45 Hz 至 65 Hz 校准 – 电学量 用标准校准器直接产生或用标准分析仪直接测量 合成电流 33 mA 至 0,33 A；谐波频率 45 Hz 至 900 Hz 33 µA 至 330 mA CMC 0,10 % + 0,10 mA 合成电流 33 mA 至 0,33 A；谐波频率 900 Hz 至 2 kHz 33 µA 至 165 mA CMC 0,10 % + 0,10 mA 合成电流 33 mA 至 0,33 A；谐波频率 2 kHz 至 5 kHz 33 µA 至 99 mA CMC 0,10 % + 0,10 mA 合成电流 0,33 A 至 3 A；谐波频率 45 Hz 至 900 Hz 330 µA 至 3 A CMC 0,10 % + 1,0 mA 合成电流 0,33 A 至 3 A；谐波频率 900 Hz 至 2 kHz 330 µA 至 0,60 A CMC 0,10 % + 1,0 mA 合成电流 0,33 A 至 3 A；谐波频率 2 kHz 至 5 kHz 330 µA 至 0,60 A CMC 0,20 % + 1,3 mA 合成电流 3 A 至 20,5 A；谐波频率 45 Hz 至 900 Hz 3 mA 至 20,5 A CMC 0,10 % + 10 mA 合成电流 3 A 至 20,5 A；谐波频率 900 Hz 至 2 kHz 3 mA 至 4,1 A CMC 0,10 % + 10 mA 合成电流 3 A 至 20,5 A；谐波频率 2 kHz 至 5 kHz 3 mA 至 4,1 A CMC 0,20 % + 10 mA MK9, MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5e4426184e5987b5563dae30","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"9","test_object":"Prąd w.cz. / sondy prądowe, boczniki","test_object_en":"RF current / Current probes, shunts","test_object_zh":"射频电流 / 电流探头、分流器","test_object_cs":"Vf proud / Proudové sondy, bočníky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz do 100 MHz","range":"od 0,1 mA do 20 mA","cmc":"1,5 % + 0,7 µA"},{"name":"100 MHz do 250 MHz","range":"od 0,1 mA do 20 mA","cmc":"2,0 % + 0,7 µA"},{"name":"1 kHz do 100 MHz","range":"od 20 mA do 40 mA","cmc":"1,5 %"},{"name":"100 MHz do 250 MHz","range":"od 20 mA do 40 mA","cmc":"2,0 %"},{"name":"1 kHz do 50 MHz","range":"od 40 mA do 70 mA","cmc":"1,5 %"}],"parameters_en":[{"name":"1 kHz to 100 MHz","range":"0,1 mA to 20 mA","cmc":"1,5 % + 0,7 µA"},{"name":"100 MHz to 250 MHz","range":"0,1 mA to 20 mA","cmc":"2,0 % + 0,7 µA"},{"name":"1 kHz to 100 MHz","range":"20 mA to 40 mA","cmc":"1,5 %"},{"name":"100 MHz to 250 MHz","range":"20 mA to 40 mA","cmc":"2,0 %"},{"name":"1 kHz to 50 MHz","range":"40 mA to 70 mA","cmc":"1,5 %"}],"parameters_zh":[{"name":"1 kHz 至 100 MHz","range":"0,1 mA 至 20 mA","cmc":"1,5 % + 0,7 µA"},{"name":"100 MHz 至 250 MHz","range":"0,1 mA 至 20 mA","cmc":"2,0 % + 0,7 µA"},{"name":"1 kHz 至 100 MHz","range":"20 mA 至 40 mA","cmc":"1,5 %"},{"name":"100 MHz 至 250 MHz","range":"20 mA 至 40 mA","cmc":"2,0 %"},{"name":"1 kHz 至 50 MHz","range":"40 mA 至 70 mA","cmc":"1,5 %"}],"parameters_cs":[{"name":"1 kHz až 100 MHz","range":"0,1 mA až 20 mA","cmc":"1,5 % + 0,7 µA"},{"name":"100 MHz až 250 MHz","range":"0,1 mA až 20 mA","cmc":"2,0 % + 0,7 µA"},{"name":"1 kHz až 100 MHz","range":"20 mA až 40 mA","cmc":"1,5 %"},{"name":"100 MHz až 250 MHz","range":"20 mA až 40 mA","cmc":"2,0 %"},{"name":"1 kHz až 50 MHz","range":"40 mA až 70 mA","cmc":"1,5 %"}],"technique":"Generowanie generatorem wzorcowym z przyrządem kalibracyjnym","technique_en":"Generation by a standard generator with a calibration fixture","technique_zh":"用带校准夹具的标准发生器产生","technique_cs":"Generování etalonovým generátorem s kalibračním přípravkem","techniques":["Generowanie generatorem wzorcowym z przyrządem kalibracyjnym"],"techniques_en":["Generation by a standard generator with a calibration fixture"],"techniques_zh":["用带校准夹具的标准发生器产生"],"techniques_cs":["Generování etalonovým generátorem s kalibračním přípravkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz do 100 MHz od 0,1 mA do 20 mA CMC 1,5 % + 0,7 µA\n100 MHz do 250 MHz od 0,1 mA do 20 mA CMC 2,0 % + 0,7 µA\n1 kHz do 100 MHz od 20 mA do 40 mA CMC 1,5 %\n100 MHz do 250 MHz od 20 mA do 40 mA CMC 2,0 %\n1 kHz do 50 MHz od 40 mA do 70 mA CMC 1,5 %\nGenerowanie generatorem wzorcowym z przyrządem kalibracyjnym","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd w.cz. / sondy prądowe, boczniki Wzorcowanie – wielkości elektryczne Generowanie generatorem wzorcowym z przyrządem kalibracyjnym 1 kHz do 100 MHz od 0,1 mA do 20 mA CMC 1,5 % + 0,7 µA 100 MHz do 250 MHz od 0,1 mA do 20 mA CMC 2,0 % + 0,7 µA 1 kHz do 100 MHz od 20 mA do 40 mA CMC 1,5 % 100 MHz do 250 MHz od 20 mA do 40 mA CMC 2,0 % 1 kHz do 50 MHz od 40 mA do 70 mA CMC 1,5 % Vf proud / Proudové sondy, bočníky Kalibrace – elektrické veličiny Generování etalonovým generátorem s kalibračním přípravkem 1 kHz až 100 MHz 0,1 mA až 20 mA CMC 1,5 % + 0,7 µA 100 MHz až 250 MHz 0,1 mA až 20 mA CMC 2,0 % + 0,7 µA 1 kHz až 100 MHz 20 mA až 40 mA CMC 1,5 % 100 MHz až 250 MHz 20 mA až 40 mA CMC 2,0 % 1 kHz až 50 MHz 40 mA až 70 mA CMC 1,5 % MK16 Prad w.cz. / sondy pradowe, boczniki Wzorcowanie – wielkosci elektryczne Generowanie generatorem wzorcowym z przyrzadem kalibracyjnym 1 kHz do 100 MHz od 0,1 mA do 20 mA CMC 1,5 % + 0,7 µA 100 MHz do 250 MHz od 0,1 mA do 20 mA CMC 2,0 % + 0,7 µA 1 kHz do 100 MHz od 20 mA do 40 mA CMC 1,5 % 100 MHz do 250 MHz od 20 mA do 40 mA CMC 2,0 % 1 kHz do 50 MHz od 40 mA do 70 mA CMC 1,5 % Vf proud / Proudove sondy, bocniky Kalibrace – elektricke veliciny Generovani etalonovym generatorem s kalibracnim pripravkem 1 kHz az 100 MHz 0,1 mA az 20 mA CMC 1,5 % + 0,7 µA 100 MHz az 250 MHz 0,1 mA az 20 mA CMC 2,0 % + 0,7 µA 1 kHz az 100 MHz 20 mA az 40 mA CMC 1,5 % 100 MHz az 250 MHz 20 mA az 40 mA CMC 2,0 % 1 kHz az 50 MHz 40 mA az 70 mA CMC 1,5 % MK16","search_en":"RF current / Current probes, shunts Calibration – electrical quantities Generation by a standard generator with a calibration fixture 1 kHz to 100 MHz 0,1 mA to 20 mA CMC 1,5 % + 0,7 µA 100 MHz to 250 MHz 0,1 mA to 20 mA CMC 2,0 % + 0,7 µA 1 kHz to 100 MHz 20 mA to 40 mA CMC 1,5 % 100 MHz to 250 MHz 20 mA to 40 mA CMC 2,0 % 1 kHz to 50 MHz 40 mA to 70 mA CMC 1,5 % MK16","search_zh":"射频电流 / 电流探头、分流器 校准 – 电学量 用带校准夹具的标准发生器产生 1 kHz 至 100 MHz 0,1 mA 至 20 mA CMC 1,5 % + 0,7 µA 100 MHz 至 250 MHz 0,1 mA 至 20 mA CMC 2,0 % + 0,7 µA 1 kHz 至 100 MHz 20 mA 至 40 mA CMC 1,5 % 100 MHz 至 250 MHz 20 mA 至 40 mA CMC 2,0 % 1 kHz 至 50 MHz 40 mA 至 70 mA CMC 1,5 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5bbbe96529b03d36c8da79a4","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"9","test_object":"Prąd w.cz. / sondy prądowe, boczniki","test_object_en":"RF current / Current probes, shunts","test_object_zh":"射频电流 / 电流探头、分流器","test_object_cs":"Vf proud / Proudové sondy, bočníky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"250 MHz do 1 GHz","range":"od 0,1 mA do 20 mA","cmc":"3,0 % + 0,7 µA"}],"parameters_en":[{"name":"250 MHz to 1 GHz","range":"0,1 mA to 20 mA","cmc":"3,0 % + 0,7 µA"}],"parameters_zh":[{"name":"250 MHz 至 1 GHz","range":"0,1 mA 至 20 mA","cmc":"3,0 % + 0,7 µA"}],"parameters_cs":[{"name":"250 MHz až 1 GHz","range":"0,1 mA až 20 mA","cmc":"3,0 % + 0,7 µA"}],"technique":"Porównanie z watomierzem wzorcowym na przyrządzie kalibracyjnym","technique_en":"Comparison with a standard power meter on a calibration fixture","technique_zh":"在校准夹具上与标准功率计比较","technique_cs":"Porovnání s etalonovým wattmetrem na kalibračním přípravku","techniques":["Porównanie z watomierzem wzorcowym na przyrządzie kalibracyjnym"],"techniques_en":["Comparison with a standard power meter on a calibration fixture"],"techniques_zh":["在校准夹具上与标准功率计比较"],"techniques_cs":["Porovnání s etalonovým wattmetrem na kalibračním přípravku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n250 MHz do 1 GHz od 0,1 mA do 20 mA CMC 3,0 % + 0,7 µA\nPorównanie z watomierzem wzorcowym na przyrządzie kalibracyjnym","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd w.cz. / sondy prądowe, boczniki Wzorcowanie – wielkości elektryczne Porównanie z watomierzem wzorcowym na przyrządzie kalibracyjnym 250 MHz do 1 GHz od 0,1 mA do 20 mA CMC 3,0 % + 0,7 µA Vf proud / Proudové sondy, bočníky Kalibrace – elektrické veličiny Porovnání s etalonovým wattmetrem na kalibračním přípravku 250 MHz až 1 GHz 0,1 mA až 20 mA CMC 3,0 % + 0,7 µA MK16 Prad w.cz. / sondy pradowe, boczniki Wzorcowanie – wielkosci elektryczne Porownanie z watomierzem wzorcowym na przyrzadzie kalibracyjnym 250 MHz do 1 GHz od 0,1 mA do 20 mA CMC 3,0 % + 0,7 µA Vf proud / Proudove sondy, bocniky Kalibrace – elektricke veliciny Porovnani s etalonovym wattmetrem na kalibracnim pripravku 250 MHz az 1 GHz 0,1 mA az 20 mA CMC 3,0 % + 0,7 µA MK16","search_en":"RF current / Current probes, shunts Calibration – electrical quantities Comparison with a standard power meter on a calibration fixture 250 MHz to 1 GHz 0,1 mA to 20 mA CMC 3,0 % + 0,7 µA MK16","search_zh":"射频电流 / 电流探头、分流器 校准 – 电学量 在校准夹具上与标准功率计比较 250 MHz 至 1 GHz 0,1 mA 至 20 mA CMC 3,0 % + 0,7 µA MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"abd892e62cc9f04f248ef8bb","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"10","test_object":"Prąd impulsowy / generatory probiercze","test_object_en":"Pulse current / Test generators","test_object_zh":"脉冲电流 / 试验发生器","test_object_cs":"Impulsní proud / Zkušební generátory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"wartość szczytowa, prostokąt, sinus; szerokość > 5 ms","range":"od 1 mA do 10 A","cmc":"0,50 %"}],"parameters_en":[{"name":"peak value, square wave, sine; width > 5 ms","range":"1 mA to 10 A","cmc":"0,50 %"}],"parameters_zh":[{"name":"峰值，方波，正弦；宽度 > 5 ms","range":"1 mA 至 10 A","cmc":"0,50 %"}],"parameters_cs":[{"name":"vrcholová hodnota, obdélník, sinus; šířka > 5 ms","range":"1 mA až 10 A","cmc":"0,50 %"}],"technique":"Pomiar digitizerem wzorcowym z bocznikiem","technique_en":"Measurement by a standard digitizer with a shunt","technique_zh":"用带分流器的标准数字化仪测量","technique_cs":"Měření etalonovým digitizérem s bočníkem","techniques":["Pomiar digitizerem wzorcowym z bocznikiem"],"techniques_en":["Measurement by a standard digitizer with a shunt"],"techniques_zh":["用带分流器的标准数字化仪测量"],"techniques_cs":["Měření etalonovým digitizérem s bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nwartość szczytowa, prostokąt, sinus; szerokość > 5 ms od 1 mA do 10 A CMC 0,50 %\nPomiar digitizerem wzorcowym z bocznikiem","reference":"MK9","norm_bases":["MK9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd impulsowy / generatory probiercze Wzorcowanie – wielkości elektryczne Pomiar digitizerem wzorcowym z bocznikiem wartość szczytowa, prostokąt, sinus; szerokość > 5 ms od 1 mA do 10 A CMC 0,50 % Impulsní proud / Zkušební generátory Kalibrace – elektrické veličiny Měření etalonovým digitizérem s bočníkem vrcholová hodnota, obdélník, sinus; šířka > 5 ms 1 mA až 10 A CMC 0,50 % MK9 Prad impulsowy / generatory probiercze Wzorcowanie – wielkosci elektryczne Pomiar digitizerem wzorcowym z bocznikiem wartosc szczytowa, prostokat, sinus; szerokosc > 5 ms od 1 mA do 10 A CMC 0,50 % Impulsni proud / Zkusebni generatory Kalibrace – elektricke veliciny Mereni etalonovym digitizerem s bocnikem vrcholova hodnota, obdelnik, sinus; sirka > 5 ms 1 mA az 10 A CMC 0,50 % MK9","search_en":"Pulse current / Test generators Calibration – electrical quantities Measurement by a standard digitizer with a shunt peak value, square wave, sine; width > 5 ms 1 mA to 10 A CMC 0,50 % MK9","search_zh":"脉冲电流 / 试验发生器 校准 – 电学量 用带分流器的标准数字化仪测量 峰值，方波，正弦；宽度 > 5 ms 1 mA 至 10 A CMC 0,50 % MK9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"206d455bfb6156eec42b7bdd","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"11","test_object":"Wyładowanie kontaktowe ESD / generatory ESD","test_object_en":"ESD contact discharge / ESD generators","test_object_zh":"ESD 接触放电 / ESD 发生器","test_object_cs":"ESD kontaktní výboj / Generátory ESD","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,2 A do 60 A","cmc":"5,0 %"}],"parameters_en":[{"name":"","range":"0,2 A to 60 A","cmc":"5,0 %"}],"parameters_zh":[{"name":"","range":"0,2 A 至 60 A","cmc":"5,0 %"}],"parameters_cs":[{"name":"","range":"0,2 A až 60 A","cmc":"5,0 %"}],"technique":"Pomiar oscyloskopem wzorcowym z tarczą ESD","technique_en":"Measurement by a standard oscilloscope with an ESD target","technique_zh":"用带 ESD 靶的标准示波器测量","technique_cs":"Měření etalonovým osciloskopem s ESD terčem","techniques":["Pomiar oscyloskopem wzorcowym z tarczą ESD"],"techniques_en":["Measurement by a standard oscilloscope with an ESD target"],"techniques_zh":["用带 ESD 靶的标准示波器测量"],"techniques_cs":["Měření etalonovým osciloskopem s ESD terčem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 0,2 A do 60 A CMC 5,0 %\nPomiar oscyloskopem wzorcowym z tarczą ESD","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wyładowanie kontaktowe ESD / generatory ESD Wzorcowanie – wielkości elektryczne Pomiar oscyloskopem wzorcowym z tarczą ESD od 0,2 A do 60 A CMC 5,0 % ESD kontaktní výboj / Generátory ESD Kalibrace – elektrické veličiny Měření etalonovým osciloskopem s ESD terčem 0,2 A až 60 A CMC 5,0 % MK16 Wyladowanie kontaktowe ESD / generatory ESD Wzorcowanie – wielkosci elektryczne Pomiar oscyloskopem wzorcowym z tarcza ESD od 0,2 A do 60 A CMC 5,0 % ESD kontaktni vyboj / Generatory ESD Kalibrace – elektricke veliciny Mereni etalonovym osciloskopem s ESD tercem 0,2 A az 60 A CMC 5,0 % MK16","search_en":"ESD contact discharge / ESD generators Calibration – electrical quantities Measurement by a standard oscilloscope with an ESD target 0,2 A to 60 A CMC 5,0 % MK16","search_zh":"ESD 接触放电 / ESD 发生器 校准 – 电学量 用带 ESD 靶的标准示波器测量 0,2 A 至 60 A CMC 5,0 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0afcb535de45ff451b1994a3","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"12","test_object":"Udarowy impuls prądowy / generatory impulsów udarowych","test_object_en":"Surge current pulse / Surge pulse generators","test_object_zh":"浪涌电流脉冲 / 浪涌脉冲发生器","test_object_cs":"Rázový proudový impuls / Generátory rázového impulsu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"czas narastania > 150 ns","range":"od 0,4 A do 500 A","cmc":"3,0 % + 2 mA"}],"parameters_en":[{"name":"rise time > 150 ns","range":"0,4 A to 500 A","cmc":"3,0 % + 2 mA"}],"parameters_zh":[{"name":"上升时间 > 150 ns","range":"0,4 A 至 500 A","cmc":"3,0 % + 2 mA"}],"parameters_cs":[{"name":"doba náběhu > 150 ns","range":"0,4 A až 500 A","cmc":"3,0 % + 2 mA"}],"technique":"Pomiar oscyloskopem wzorcowym z sondą prądową","technique_en":"Measurement by a standard oscilloscope with a current probe","technique_zh":"用带电流探头的标准示波器测量","technique_cs":"Měření etalonovým osciloskopem s proudovou sondou","techniques":["Pomiar oscyloskopem wzorcowym z sondą prądową"],"techniques_en":["Measurement by a standard oscilloscope with a current probe"],"techniques_zh":["用带电流探头的标准示波器测量"],"techniques_cs":["Měření etalonovým osciloskopem s proudovou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nczas narastania > 150 ns od 0,4 A do 500 A CMC 3,0 % + 2 mA\nPomiar oscyloskopem wzorcowym z sondą prądową","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Udarowy impuls prądowy / generatory impulsów udarowych Wzorcowanie – wielkości elektryczne Pomiar oscyloskopem wzorcowym z sondą prądową czas narastania > 150 ns od 0,4 A do 500 A CMC 3,0 % + 2 mA Rázový proudový impuls / Generátory rázového impulsu Kalibrace – elektrické veličiny Měření etalonovým osciloskopem s proudovou sondou doba náběhu > 150 ns 0,4 A až 500 A CMC 3,0 % + 2 mA MK16 Udarowy impuls pradowy / generatory impulsow udarowych Wzorcowanie – wielkosci elektryczne Pomiar oscyloskopem wzorcowym z sonda pradowa czas narastania > 150 ns od 0,4 A do 500 A CMC 3,0 % + 2 mA Razovy proudovy impuls / Generatory razoveho impulsu Kalibrace – elektricke veliciny Mereni etalonovym osciloskopem s proudovou sondou doba nabehu > 150 ns 0,4 A az 500 A CMC 3,0 % + 2 mA MK16","search_en":"Surge current pulse / Surge pulse generators Calibration – electrical quantities Measurement by a standard oscilloscope with a current probe rise time > 150 ns 0,4 A to 500 A CMC 3,0 % + 2 mA MK16","search_zh":"浪涌电流脉冲 / 浪涌脉冲发生器 校准 – 电学量 用带电流探头的标准示波器测量 上升时间 > 150 ns 0,4 A 至 500 A CMC 3,0 % + 2 mA MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4555fe37664145efa6b64623","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"12","test_object":"Udarowy impuls prądowy / generatory impulsów udarowych","test_object_en":"Surge current pulse / Surge pulse generators","test_object_zh":"浪涌电流脉冲 / 浪涌脉冲发生器","test_object_cs":"Rázový proudový impuls / Generátory rázového impulsu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"czas narastania > 1,2 µs","range":"od 500 A do 2,5 kA","cmc":"3,0 %"}],"parameters_en":[{"name":"rise time > 1,2 µs","range":"500 A to 2,5 kA","cmc":"3,0 %"}],"parameters_zh":[{"name":"上升时间 > 1,2 µs","range":"500 A 至 2,5 kA","cmc":"3,0 %"}],"parameters_cs":[{"name":"doba náběhu > 1,2 µs","range":"500 A až 2,5 kA","cmc":"3,0 %"}],"technique":"Pomiar oscyloskopem wzorcowym z bocznikiem","technique_en":"Measurement by a standard oscilloscope with a shunt","technique_zh":"用带分流器的标准示波器测量","technique_cs":"Měření etalonovým osciloskopem s bočníkem","techniques":["Pomiar oscyloskopem wzorcowym z bocznikiem"],"techniques_en":["Measurement by a standard oscilloscope with a shunt"],"techniques_zh":["用带分流器的标准示波器测量"],"techniques_cs":["Měření etalonovým osciloskopem s bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nczas narastania > 1,2 µs od 500 A do 2,5 kA CMC 3,0 %\nPomiar oscyloskopem wzorcowym z bocznikiem","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Udarowy impuls prądowy / generatory impulsów udarowych Wzorcowanie – wielkości elektryczne Pomiar oscyloskopem wzorcowym z bocznikiem czas narastania > 1,2 µs od 500 A do 2,5 kA CMC 3,0 % Rázový proudový impuls / Generátory rázového impulsu Kalibrace – elektrické veličiny Měření etalonovým osciloskopem s bočníkem doba náběhu > 1,2 µs 500 A až 2,5 kA CMC 3,0 % MK16 Udarowy impuls pradowy / generatory impulsow udarowych Wzorcowanie – wielkosci elektryczne Pomiar oscyloskopem wzorcowym z bocznikiem czas narastania > 1,2 µs od 500 A do 2,5 kA CMC 3,0 % Razovy proudovy impuls / Generatory razoveho impulsu Kalibrace – elektricke veliciny Mereni etalonovym osciloskopem s bocnikem doba nabehu > 1,2 µs 500 A az 2,5 kA CMC 3,0 % MK16","search_en":"Surge current pulse / Surge pulse generators Calibration – electrical quantities Measurement by a standard oscilloscope with a shunt rise time > 1,2 µs 500 A to 2,5 kA CMC 3,0 % MK16","search_zh":"浪涌电流脉冲 / 浪涌脉冲发生器 校准 – 电学量 用带分流器的标准示波器测量 上升时间 > 1,2 µs 500 A 至 2,5 kA CMC 3,0 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fcc61a7e506c4d73bc76ab70","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"13","test_object":"Spawarki impulsowe","test_object_en":"Pulse welders","test_object_zh":"脉冲焊机","test_object_cs":"Impulsní svářečky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"szerokość > 5 ms","range":"od 50 A do 5 kA","cmc":"2,0 %"}],"parameters_en":[{"name":"width > 5 ms","range":"50 A to 5 kA","cmc":"2,0 %"}],"parameters_zh":[{"name":"宽度 > 5 ms","range":"50 A 至 5 kA","cmc":"2,0 %"}],"parameters_cs":[{"name":"šířka > 5 ms","range":"50 A až 5 kA","cmc":"2,0 %"}],"technique":"Pomiar oscyloskopem wzorcowym z cęgami prądowymi","technique_en":"Measurement by a standard oscilloscope with current clamps","technique_zh":"用带电流钳的标准示波器测量","technique_cs":"Měření etalonovým osciloskopem s proudovými kleštěmi","techniques":["Pomiar oscyloskopem wzorcowym z cęgami prądowymi"],"techniques_en":["Measurement by a standard oscilloscope with current clamps"],"techniques_zh":["用带电流钳的标准示波器测量"],"techniques_cs":["Měření etalonovým osciloskopem s proudovými kleštěmi"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nszerokość > 5 ms od 50 A do 5 kA CMC 2,0 %\nPomiar oscyloskopem wzorcowym z cęgami prądowymi","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Spawarki impulsowe Wzorcowanie – wielkości elektryczne Pomiar oscyloskopem wzorcowym z cęgami prądowymi szerokość > 5 ms od 50 A do 5 kA CMC 2,0 % Impulsní svářečky Kalibrace – elektrické veličiny Měření etalonovým osciloskopem s proudovými kleštěmi šířka > 5 ms 50 A až 5 kA CMC 2,0 % MK16 Spawarki impulsowe Wzorcowanie – wielkosci elektryczne Pomiar oscyloskopem wzorcowym z cegami pradowymi szerokosc > 5 ms od 50 A do 5 kA CMC 2,0 % Impulsni svarecky Kalibrace – elektricke veliciny Mereni etalonovym osciloskopem s proudovymi klestemi sirka > 5 ms 50 A az 5 kA CMC 2,0 % MK16","search_en":"Pulse welders Calibration – electrical quantities Measurement by a standard oscilloscope with current clamps width > 5 ms 50 A to 5 kA CMC 2,0 % MK16","search_zh":"脉冲焊机 校准 – 电学量 用带电流钳的标准示波器测量 宽度 > 5 ms 50 A 至 5 kA CMC 2,0 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"beea7d641003296c40e9f34d","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"14","test_object":"Rezystancja przy prądzie stałym / miliomomierze, wzorce rezystancji","test_object_en":"DC resistance / Milliohmmeters, resistance standards","test_object_zh":"直流电阻 / 毫欧表、电阻标准","test_object_cs":"Stejnosměrný odpor / Miliohmmetry, etalony odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0,1 mΩ","cmc":"0,050 %"},{"name":"","range":"1 mΩ","cmc":"0,0035 %"},{"name":"","range":"10 mΩ","cmc":"0,0018 %"},{"name":"","range":"100 mΩ","cmc":"0,0022 %"},{"name":"","range":"1 Ω","cmc":"0,0018 %"}],"parameters_en":[{"name":"","range":"0,1 mΩ","cmc":"0,050 %"},{"name":"","range":"1 mΩ","cmc":"0,0035 %"},{"name":"","range":"10 mΩ","cmc":"0,0018 %"},{"name":"","range":"100 mΩ","cmc":"0,0022 %"},{"name":"","range":"1 Ω","cmc":"0,0018 %"}],"parameters_zh":[{"name":"","range":"0,1 mΩ","cmc":"0,050 %"},{"name":"","range":"1 mΩ","cmc":"0,0035 %"},{"name":"","range":"10 mΩ","cmc":"0,0018 %"},{"name":"","range":"100 mΩ","cmc":"0,0022 %"},{"name":"","range":"1 Ω","cmc":"0,0018 %"}],"parameters_cs":[{"name":"","range":"0,1 mΩ","cmc":"0,050 %"},{"name":"","range":"1 mΩ","cmc":"0,0035 %"},{"name":"","range":"10 mΩ","cmc":"0,0018 %"},{"name":"","range":"100 mΩ","cmc":"0,0022 %"},{"name":"","range":"1 Ω","cmc":"0,0018 %"}],"technique":"Wzorce rezystancji: pomiar bezpośredni lub porównanie","technique_en":"Resistance standards: direct measurement or comparison","technique_zh":"电阻标准：直接测量或比较","technique_cs":"Etalony odporu: přímé měření nebo porovnání","techniques":["Wzorce rezystancji: pomiar bezpośredni lub porównanie"],"techniques_en":["Resistance standards: direct measurement or comparison"],"techniques_zh":["电阻标准：直接测量或比较"],"techniques_cs":["Etalony odporu: přímé měření nebo porovnání"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 mΩ CMC 0,050 %\n1 mΩ CMC 0,0035 %\n10 mΩ CMC 0,0018 %\n100 mΩ CMC 0,0022 %\n1 Ω CMC 0,0018 %\nWzorce rezystancji: pomiar bezpośredni lub porównanie","reference":"MK12, MK13","norm_bases":["MK12","MK13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / miliomomierze, wzorce rezystancji Wzorcowanie – wielkości elektryczne Wzorce rezystancji: pomiar bezpośredni lub porównanie 0,1 mΩ CMC 0,050 % 1 mΩ CMC 0,0035 % 10 mΩ CMC 0,0018 % 100 mΩ CMC 0,0022 % 1 Ω CMC 0,0018 % Stejnosměrný odpor / Miliohmmetry, etalony odporu Kalibrace – elektrické veličiny Etalony odporu: přímé měření nebo porovnání 0,1 mΩ CMC 0,050 % 1 mΩ CMC 0,0035 % 10 mΩ CMC 0,0018 % 100 mΩ CMC 0,0022 % 1 Ω CMC 0,0018 % MK12, MK13 Rezystancja przy pradzie stalym / miliomomierze, wzorce rezystancji Wzorcowanie – wielkosci elektryczne Wzorce rezystancji: pomiar bezposredni lub porownanie 0,1 mΩ CMC 0,050 % 1 mΩ CMC 0,0035 % 10 mΩ CMC 0,0018 % 100 mΩ CMC 0,0022 % 1 Ω CMC 0,0018 % Stejnosmerny odpor / Miliohmmetry, etalony odporu Kalibrace – elektricke veliciny Etalony odporu: prime mereni nebo porovnani 0,1 mΩ CMC 0,050 % 1 mΩ CMC 0,0035 % 10 mΩ CMC 0,0018 % 100 mΩ CMC 0,0022 % 1 Ω CMC 0,0018 % MK12, MK13","search_en":"DC resistance / Milliohmmeters, resistance standards Calibration – electrical quantities Resistance standards: direct measurement or comparison 0,1 mΩ CMC 0,050 % 1 mΩ CMC 0,0035 % 10 mΩ CMC 0,0018 % 100 mΩ CMC 0,0022 % 1 Ω CMC 0,0018 % MK12, MK13","search_zh":"直流电阻 / 毫欧表、电阻标准 校准 – 电学量 电阻标准：直接测量或比较 0,1 mΩ CMC 0,050 % 1 mΩ CMC 0,0035 % 10 mΩ CMC 0,0018 % 100 mΩ CMC 0,0022 % 1 Ω CMC 0,0018 % MK12, MK13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0b0176fdcdea5c6ddde8836","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"14","test_object":"Rezystancja przy prądzie stałym / omomierze, multimetry, wzorce rezystancji, dekady rezystancyjne, mierniki do badań instalacji","test_object_en":"DC resistance / Ohmmeters, multimeters, resistance standards, resistance decades, installation testers","test_object_zh":"直流电阻 / 欧姆表、万用表、电阻标准、电阻箱、电气安装测试仪","test_object_cs":"Stejnosměrný odpor / Ohmmetry, multimetry, etalony odporu, odporové dekády, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mΩ do 20 Ω","cmc":"0,0024 % + 20 µΩ"},{"name":"","range":"od 20 Ω do 200 Ω","cmc":"0,0015 %"},{"name":"","range":"od 200 Ω do 20 kΩ","cmc":"0,0012 %"},{"name":"","range":"od 20 kΩ do 200 kΩ","cmc":"0,0014 %"}],"parameters_en":[{"name":"","range":"0 mΩ to 20 Ω","cmc":"0,0024 % + 20 µΩ"},{"name":"","range":"20 Ω to 200 Ω","cmc":"0,0015 %"},{"name":"","range":"200 Ω to 20 kΩ","cmc":"0,0012 %"},{"name":"","range":"20 kΩ to 200 kΩ","cmc":"0,0014 %"}],"parameters_zh":[{"name":"","range":"0 mΩ 至 20 Ω","cmc":"0,0024 % + 20 µΩ"},{"name":"","range":"20 Ω 至 200 Ω","cmc":"0,0015 %"},{"name":"","range":"200 Ω 至 20 kΩ","cmc":"0,0012 %"},{"name":"","range":"20 kΩ 至 200 kΩ","cmc":"0,0014 %"}],"parameters_cs":[{"name":"","range":"0 mΩ až 20 Ω","cmc":"0,0024 % + 20 µΩ"},{"name":"","range":"20 Ω až 200 Ω","cmc":"0,0015 %"},{"name":"","range":"200 Ω až 20 kΩ","cmc":"0,0012 %"},{"name":"","range":"20 kΩ až 200 kΩ","cmc":"0,0014 %"}],"technique":"Multimetr wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter: comparison or direct measurement","technique_zh":"标准万用表：比较或直接测量","technique_cs":"Etalonový multimetr: porovnání nebo přímé měření","techniques":["Multimetr wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter: comparison or direct measurement"],"techniques_zh":["标准万用表：比较或直接测量"],"techniques_cs":["Etalonový multimetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mΩ do 20 Ω CMC 0,0024 % + 20 µΩ\nod 20 Ω do 200 Ω CMC 0,0015 %\nod 200 Ω do 20 kΩ CMC 0,0012 %\nod 20 kΩ do 200 kΩ CMC 0,0014 %\nMultimetr wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK4, MK8, MK11, MK12, MK13","norm_bases":["MK4","MK8","MK11","MK12","MK13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / omomierze, multimetry, wzorce rezystancji, dekady rezystancyjne, mierniki do badań instalacji Wzorcowanie – wielkości elektryczne Multimetr wzorcowy: porównanie lub pomiar bezpośredni od 0 mΩ do 20 Ω CMC 0,0024 % + 20 µΩ od 20 Ω do 200 Ω CMC 0,0015 % od 200 Ω do 20 kΩ CMC 0,0012 % od 20 kΩ do 200 kΩ CMC 0,0014 % Stejnosměrný odpor / Ohmmetry, multimetry, etalony odporu, odporové dekády, revizní přístroje Kalibrace – elektrické veličiny Etalonový multimetr: porovnání nebo přímé měření 0 mΩ až 20 Ω CMC 0,0024 % + 20 µΩ 20 Ω až 200 Ω CMC 0,0015 % 200 Ω až 20 kΩ CMC 0,0012 % 20 kΩ až 200 kΩ CMC 0,0014 % MK4, MK8, MK11, MK12, MK13 Rezystancja przy pradzie stalym / omomierze, multimetry, wzorce rezystancji, dekady rezystancyjne, mierniki do badan instalacji Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy: porownanie lub pomiar bezposredni od 0 mΩ do 20 Ω CMC 0,0024 % + 20 µΩ od 20 Ω do 200 Ω CMC 0,0015 % od 200 Ω do 20 kΩ CMC 0,0012 % od 20 kΩ do 200 kΩ CMC 0,0014 % Stejnosmerny odpor / Ohmmetry, multimetry, etalony odporu, odporove dekady, revizni pristroje Kalibrace – elektricke veliciny Etalonovy multimetr: porovnani nebo prime mereni 0 mΩ az 20 Ω CMC 0,0024 % + 20 µΩ 20 Ω az 200 Ω CMC 0,0015 % 200 Ω az 20 kΩ CMC 0,0012 % 20 kΩ az 200 kΩ CMC 0,0014 % MK4, MK8, MK11, MK12, MK13","search_en":"DC resistance / Ohmmeters, multimeters, resistance standards, resistance decades, installation testers Calibration – electrical quantities Standard multimeter: comparison or direct measurement 0 mΩ to 20 Ω CMC 0,0024 % + 20 µΩ 20 Ω to 200 Ω CMC 0,0015 % 200 Ω to 20 kΩ CMC 0,0012 % 20 kΩ to 200 kΩ CMC 0,0014 % MK4, MK8, MK11, MK12, MK13","search_zh":"直流电阻 / 欧姆表、万用表、电阻标准、电阻箱、电气安装测试仪 校准 – 电学量 标准万用表：比较或直接测量 0 mΩ 至 20 Ω CMC 0,0024 % + 20 µΩ 20 Ω 至 200 Ω CMC 0,0015 % 200 Ω 至 20 kΩ CMC 0,0012 % 20 kΩ 至 200 kΩ CMC 0,0014 % MK4, MK8, MK11, MK12, MK13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a3963da958c18f70688bb4f","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"14","test_object":"Rezystancja przy prądzie stałym / megaomomierze, multimetry, wzorce rezystancji, dekady rezystancyjne, mierniki do badań instalacji","test_object_en":"DC resistance / Megohmmeters, multimeters, resistance standards, resistance decades, installation testers","test_object_zh":"直流电阻 / 兆欧表、万用表、电阻标准、电阻箱、电气安装测试仪","test_object_cs":"Stejnosměrný odpor / Megaohmmetry, multimetry, etalony odporu, odporové dekády, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 200 kΩ do 2 MΩ","cmc":"0,0025 % + 1,4 Ω"},{"name":"","range":"od 2 MΩ do 20 MΩ","cmc":"0,0051 % + 80 Ω"},{"name":"","range":"od 20 MΩ do 33 MΩ","cmc":"0,048 %"},{"name":"","range":"od 33 MΩ do 50 MΩ","cmc":"0,059 %"},{"name":"","range":"od 50 MΩ do 200 MΩ","cmc":"0,043 %"}],"parameters_en":[{"name":"","range":"200 kΩ to 2 MΩ","cmc":"0,0025 % + 1,4 Ω"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"0,0051 % + 80 Ω"},{"name":"","range":"20 MΩ to 33 MΩ","cmc":"0,048 %"},{"name":"","range":"33 MΩ to 50 MΩ","cmc":"0,059 %"},{"name":"","range":"50 MΩ to 200 MΩ","cmc":"0,043 %"}],"parameters_zh":[{"name":"","range":"200 kΩ 至 2 MΩ","cmc":"0,0025 % + 1,4 Ω"},{"name":"","range":"2 MΩ 至 20 MΩ","cmc":"0,0051 % + 80 Ω"},{"name":"","range":"20 MΩ 至 33 MΩ","cmc":"0,048 %"},{"name":"","range":"33 MΩ 至 50 MΩ","cmc":"0,059 %"},{"name":"","range":"50 MΩ 至 200 MΩ","cmc":"0,043 %"}],"parameters_cs":[{"name":"","range":"200 kΩ až 2 MΩ","cmc":"0,0025 % + 1,4 Ω"},{"name":"","range":"2 MΩ až 20 MΩ","cmc":"0,0051 % + 80 Ω"},{"name":"","range":"20 MΩ až 33 MΩ","cmc":"0,048 %"},{"name":"","range":"33 MΩ až 50 MΩ","cmc":"0,059 %"},{"name":"","range":"50 MΩ až 200 MΩ","cmc":"0,043 %"}],"technique":"Multimetr wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard multimeter: comparison or direct measurement","technique_zh":"标准万用表：比较或直接测量","technique_cs":"Etalonový multimetr: porovnání nebo přímé měření","techniques":["Multimetr wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard multimeter: comparison or direct measurement"],"techniques_zh":["标准万用表：比较或直接测量"],"techniques_cs":["Etalonový multimetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 200 kΩ do 2 MΩ CMC 0,0025 % + 1,4 Ω\nod 2 MΩ do 20 MΩ CMC 0,0051 % + 80 Ω\nod 20 MΩ do 33 MΩ CMC 0,048 %\nod 33 MΩ do 50 MΩ CMC 0,059 %\nod 50 MΩ do 200 MΩ CMC 0,043 %\nMultimetr wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK4, MK8, MK11, MK13, MK14","norm_bases":["MK4","MK8","MK11","MK13","MK14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / megaomomierze, multimetry, wzorce rezystancji, dekady rezystancyjne, mierniki do badań instalacji Wzorcowanie – wielkości elektryczne Multimetr wzorcowy: porównanie lub pomiar bezpośredni od 200 kΩ do 2 MΩ CMC 0,0025 % + 1,4 Ω od 2 MΩ do 20 MΩ CMC 0,0051 % + 80 Ω od 20 MΩ do 33 MΩ CMC 0,048 % od 33 MΩ do 50 MΩ CMC 0,059 % od 50 MΩ do 200 MΩ CMC 0,043 % Stejnosměrný odpor / Megaohmmetry, multimetry, etalony odporu, odporové dekády, revizní přístroje Kalibrace – elektrické veličiny Etalonový multimetr: porovnání nebo přímé měření 200 kΩ až 2 MΩ CMC 0,0025 % + 1,4 Ω 2 MΩ až 20 MΩ CMC 0,0051 % + 80 Ω 20 MΩ až 33 MΩ CMC 0,048 % 33 MΩ až 50 MΩ CMC 0,059 % 50 MΩ až 200 MΩ CMC 0,043 % MK4, MK8, MK11, MK13, MK14 Rezystancja przy pradzie stalym / megaomomierze, multimetry, wzorce rezystancji, dekady rezystancyjne, mierniki do badan instalacji Wzorcowanie – wielkosci elektryczne Multimetr wzorcowy: porownanie lub pomiar bezposredni od 200 kΩ do 2 MΩ CMC 0,0025 % + 1,4 Ω od 2 MΩ do 20 MΩ CMC 0,0051 % + 80 Ω od 20 MΩ do 33 MΩ CMC 0,048 % od 33 MΩ do 50 MΩ CMC 0,059 % od 50 MΩ do 200 MΩ CMC 0,043 % Stejnosmerny odpor / Megaohmmetry, multimetry, etalony odporu, odporove dekady, revizni pristroje Kalibrace – elektricke veliciny Etalonovy multimetr: porovnani nebo prime mereni 200 kΩ az 2 MΩ CMC 0,0025 % + 1,4 Ω 2 MΩ az 20 MΩ CMC 0,0051 % + 80 Ω 20 MΩ az 33 MΩ CMC 0,048 % 33 MΩ az 50 MΩ CMC 0,059 % 50 MΩ az 200 MΩ CMC 0,043 % MK4, MK8, MK11, MK13, MK14","search_en":"DC resistance / Megohmmeters, multimeters, resistance standards, resistance decades, installation testers Calibration – electrical quantities Standard multimeter: comparison or direct measurement 200 kΩ to 2 MΩ CMC 0,0025 % + 1,4 Ω 2 MΩ to 20 MΩ CMC 0,0051 % + 80 Ω 20 MΩ to 33 MΩ CMC 0,048 % 33 MΩ to 50 MΩ CMC 0,059 % 50 MΩ to 200 MΩ CMC 0,043 % MK4, MK8, MK11, MK13, MK14","search_zh":"直流电阻 / 兆欧表、万用表、电阻标准、电阻箱、电气安装测试仪 校准 – 电学量 标准万用表：比较或直接测量 200 kΩ 至 2 MΩ CMC 0,0025 % + 1,4 Ω 2 MΩ 至 20 MΩ CMC 0,0051 % + 80 Ω 20 MΩ 至 33 MΩ CMC 0,048 % 33 MΩ 至 50 MΩ CMC 0,059 % 50 MΩ 至 200 MΩ CMC 0,043 % MK4, MK8, MK11, MK13, MK14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"78346ffffc026de53d92629e","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"14","test_object":"Rezystancja przy prądzie stałym / gigaomomierze, wzorce rezystancji, dekady rezystancyjne","test_object_en":"DC resistance / Gigaohmmeters, resistance standards, resistance decades","test_object_zh":"直流电阻 / 吉欧表、电阻标准、电阻箱","test_object_cs":"Stejnosměrný odpor / Gigaohmmetry, etalony odporu, odporové dekády","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 200 MΩ do 1 GΩ","cmc":"0,25 %"},{"name":"100 V do 1 kV","range":"od 1 GΩ do 5 GΩ","cmc":"0,25 %"},{"name":"1 kV do 5 kV","range":"od 1 GΩ do 5 GΩ","cmc":"0,56 %"},{"name":"100 V do 500 V","range":"od 5 GΩ do 12 GΩ","cmc":"0,60 %"},{"name":"500 V do 1 kV","range":"od 5 GΩ do 12 GΩ","cmc":"0,25 %"},{"name":"1 kV do 5 kV","range":"od 5 GΩ do 12 GΩ","cmc":"0,56 %"}],"parameters_en":[{"name":"","range":"200 MΩ to 1 GΩ","cmc":"0,25 %"},{"name":"100 V to 1 kV","range":"1 GΩ to 5 GΩ","cmc":"0,25 %"},{"name":"1 kV to 5 kV","range":"1 GΩ to 5 GΩ","cmc":"0,56 %"},{"name":"100 V to 500 V","range":"5 GΩ to 12 GΩ","cmc":"0,60 %"},{"name":"500 V to 1 kV","range":"5 GΩ to 12 GΩ","cmc":"0,25 %"},{"name":"1 kV to 5 kV","range":"5 GΩ to 12 GΩ","cmc":"0,56 %"}],"parameters_zh":[{"name":"","range":"200 MΩ 至 1 GΩ","cmc":"0,25 %"},{"name":"100 V 至 1 kV","range":"1 GΩ 至 5 GΩ","cmc":"0,25 %"},{"name":"1 kV 至 5 kV","range":"1 GΩ 至 5 GΩ","cmc":"0,56 %"},{"name":"100 V 至 500 V","range":"5 GΩ 至 12 GΩ","cmc":"0,60 %"},{"name":"500 V 至 1 kV","range":"5 GΩ 至 12 GΩ","cmc":"0,25 %"},{"name":"1 kV 至 5 kV","range":"5 GΩ 至 12 GΩ","cmc":"0,56 %"}],"parameters_cs":[{"name":"","range":"200 MΩ až 1 GΩ","cmc":"0,25 %"},{"name":"100 V až 1 kV","range":"1 GΩ až 5 GΩ","cmc":"0,25 %"},{"name":"1 kV až 5 kV","range":"1 GΩ až 5 GΩ","cmc":"0,56 %"},{"name":"100 V až 500 V","range":"5 GΩ až 12 GΩ","cmc":"0,60 %"},{"name":"500 V až 1 kV","range":"5 GΩ až 12 GΩ","cmc":"0,25 %"},{"name":"1 kV až 5 kV","range":"5 GΩ až 12 GΩ","cmc":"0,56 %"}],"technique":"Metoda Ohma: porównanie za pomocą dekady rezystancyjnej lub pomiar rezystancji","technique_en":"Ohm's method: comparison using a resistance decade or resistance measurement","technique_zh":"欧姆法：借助电阻箱比较或测量电阻","technique_cs":"Ohmova metoda: porovnání pomocí odporové dekády nebo měření odporu","techniques":["Metoda Ohma: porównanie za pomocą dekady rezystancyjnej lub pomiar rezystancji"],"techniques_en":["Ohm's method: comparison using a resistance decade or resistance measurement"],"techniques_zh":["欧姆法：借助电阻箱比较或测量电阻"],"techniques_cs":["Ohmova metoda: porovnání pomocí odporové dekády nebo měření odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 200 MΩ do 1 GΩ CMC 0,25 %\n100 V do 1 kV od 1 GΩ do 5 GΩ CMC 0,25 %\n1 kV do 5 kV od 1 GΩ do 5 GΩ CMC 0,56 %\n100 V do 500 V od 5 GΩ do 12 GΩ CMC 0,60 %\n500 V do 1 kV od 5 GΩ do 12 GΩ CMC 0,25 %\n1 kV do 5 kV od 5 GΩ do 12 GΩ CMC 0,56 %\nMetoda Ohma: porównanie za pomocą dekady rezystancyjnej lub pomiar rezystancji","reference":"MK13, MK14","norm_bases":["MK13","MK14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / gigaomomierze, wzorce rezystancji, dekady rezystancyjne Wzorcowanie – wielkości elektryczne Metoda Ohma: porównanie za pomocą dekady rezystancyjnej lub pomiar rezystancji od 200 MΩ do 1 GΩ CMC 0,25 % 100 V do 1 kV od 1 GΩ do 5 GΩ CMC 0,25 % 1 kV do 5 kV od 1 GΩ do 5 GΩ CMC 0,56 % 100 V do 500 V od 5 GΩ do 12 GΩ CMC 0,60 % 500 V do 1 kV od 5 GΩ do 12 GΩ CMC 0,25 % 1 kV do 5 kV od 5 GΩ do 12 GΩ CMC 0,56 % Stejnosměrný odpor / Gigaohmmetry, etalony odporu, odporové dekády Kalibrace – elektrické veličiny Ohmova metoda: porovnání pomocí odporové dekády nebo měření odporu 200 MΩ až 1 GΩ CMC 0,25 % 100 V až 1 kV 1 GΩ až 5 GΩ CMC 0,25 % 1 kV až 5 kV 1 GΩ až 5 GΩ CMC 0,56 % 100 V až 500 V 5 GΩ až 12 GΩ CMC 0,60 % 500 V až 1 kV 5 GΩ až 12 GΩ CMC 0,25 % 1 kV až 5 kV 5 GΩ až 12 GΩ CMC 0,56 % MK13, MK14 Rezystancja przy pradzie stalym / gigaomomierze, wzorce rezystancji, dekady rezystancyjne Wzorcowanie – wielkosci elektryczne Metoda Ohma: porownanie za pomoca dekady rezystancyjnej lub pomiar rezystancji od 200 MΩ do 1 GΩ CMC 0,25 % 100 V do 1 kV od 1 GΩ do 5 GΩ CMC 0,25 % 1 kV do 5 kV od 1 GΩ do 5 GΩ CMC 0,56 % 100 V do 500 V od 5 GΩ do 12 GΩ CMC 0,60 % 500 V do 1 kV od 5 GΩ do 12 GΩ CMC 0,25 % 1 kV do 5 kV od 5 GΩ do 12 GΩ CMC 0,56 % Stejnosmerny odpor / Gigaohmmetry, etalony odporu, odporove dekady Kalibrace – elektricke veliciny Ohmova metoda: porovnani pomoci odporove dekady nebo mereni odporu 200 MΩ az 1 GΩ CMC 0,25 % 100 V az 1 kV 1 GΩ az 5 GΩ CMC 0,25 % 1 kV az 5 kV 1 GΩ az 5 GΩ CMC 0,56 % 100 V az 500 V 5 GΩ az 12 GΩ CMC 0,60 % 500 V az 1 kV 5 GΩ az 12 GΩ CMC 0,25 % 1 kV az 5 kV 5 GΩ az 12 GΩ CMC 0,56 % MK13, MK14","search_en":"DC resistance / Gigaohmmeters, resistance standards, resistance decades Calibration – electrical quantities Ohm's method: comparison using a resistance decade or resistance measurement 200 MΩ to 1 GΩ CMC 0,25 % 100 V to 1 kV 1 GΩ to 5 GΩ CMC 0,25 % 1 kV to 5 kV 1 GΩ to 5 GΩ CMC 0,56 % 100 V to 500 V 5 GΩ to 12 GΩ CMC 0,60 % 500 V to 1 kV 5 GΩ to 12 GΩ CMC 0,25 % 1 kV to 5 kV 5 GΩ to 12 GΩ CMC 0,56 % MK13, MK14","search_zh":"直流电阻 / 吉欧表、电阻标准、电阻箱 校准 – 电学量 欧姆法：借助电阻箱比较或测量电阻 200 MΩ 至 1 GΩ CMC 0,25 % 100 V 至 1 kV 1 GΩ 至 5 GΩ CMC 0,25 % 1 kV 至 5 kV 1 GΩ 至 5 GΩ CMC 0,56 % 100 V 至 500 V 5 GΩ 至 12 GΩ CMC 0,60 % 500 V 至 1 kV 5 GΩ 至 12 GΩ CMC 0,25 % 1 kV 至 5 kV 5 GΩ 至 12 GΩ CMC 0,56 % MK13, MK14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"42cfae971f08dd2039c2ea35","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"14","test_object":"Rezystancja przy prądzie stałym / wzorce rezystancji","test_object_en":"DC resistance / Resistance standards","test_object_zh":"直流电阻 / 电阻标准","test_object_cs":"Stejnosměrný odpor / Etalony odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 V do 5 kV","range":"od 12 GΩ do 100 GΩ","cmc":"0,60 %"}],"parameters_en":[{"name":"100 V to 5 kV","range":"12 GΩ to 100 GΩ","cmc":"0,60 %"}],"parameters_zh":[{"name":"100 V 至 5 kV","range":"12 GΩ 至 100 GΩ","cmc":"0,60 %"}],"parameters_cs":[{"name":"100 V až 5 kV","range":"12 GΩ až 100 GΩ","cmc":"0,60 %"}],"technique":"Metoda Ohma","technique_en":"Ohm's method","technique_zh":"欧姆法","technique_cs":"Ohmova metoda","techniques":["Metoda Ohma"],"techniques_en":["Ohm's method"],"techniques_zh":["欧姆法"],"techniques_cs":["Ohmova metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n100 V do 5 kV od 12 GΩ do 100 GΩ CMC 0,60 %\nMetoda Ohma","reference":"MK13","norm_bases":["MK13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / wzorce rezystancji Wzorcowanie – wielkości elektryczne Metoda Ohma 100 V do 5 kV od 12 GΩ do 100 GΩ CMC 0,60 % Stejnosměrný odpor / Etalony odporu Kalibrace – elektrické veličiny Ohmova metoda 100 V až 5 kV 12 GΩ až 100 GΩ CMC 0,60 % MK13 Rezystancja przy pradzie stalym / wzorce rezystancji Wzorcowanie – wielkosci elektryczne Metoda Ohma 100 V do 5 kV od 12 GΩ do 100 GΩ CMC 0,60 % Stejnosmerny odpor / Etalony odporu Kalibrace – elektricke veliciny Ohmova metoda 100 V az 5 kV 12 GΩ az 100 GΩ CMC 0,60 % MK13","search_en":"DC resistance / Resistance standards Calibration – electrical quantities Ohm's method 100 V to 5 kV 12 GΩ to 100 GΩ CMC 0,60 % MK13","search_zh":"直流电阻 / 电阻标准 校准 – 电学量 欧姆法 100 V 至 5 kV 12 GΩ 至 100 GΩ CMC 0,60 % MK13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d0acf1f326ab2f35586a2bc","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"14","test_object":"Rezystancja przy prądzie stałym / teraomomierze, wzorce rezystancji","test_object_en":"DC resistance / Teraohmmeters, resistance standards","test_object_zh":"直流电阻 / 太欧表、电阻标准","test_object_cs":"Stejnosměrný odpor / Teraohmmetry, etalony odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 V do 1 kV","range":"1 GΩ","cmc":"0,030 %"},{"name":"100 V do 1 kV","range":"10 GΩ","cmc":"0,20 %"},{"name":"100 V do 1 kV","range":"100 GΩ","cmc":"0,40 %"},{"name":"100 V do 1 kV","range":"1 TΩ","cmc":"0,50 %"}],"parameters_en":[{"name":"100 V to 1 kV","range":"1 GΩ","cmc":"0,030 %"},{"name":"100 V to 1 kV","range":"10 GΩ","cmc":"0,20 %"},{"name":"100 V to 1 kV","range":"100 GΩ","cmc":"0,40 %"},{"name":"100 V to 1 kV","range":"1 TΩ","cmc":"0,50 %"}],"parameters_zh":[{"name":"100 V 至 1 kV","range":"1 GΩ","cmc":"0,030 %"},{"name":"100 V 至 1 kV","range":"10 GΩ","cmc":"0,20 %"},{"name":"100 V 至 1 kV","range":"100 GΩ","cmc":"0,40 %"},{"name":"100 V 至 1 kV","range":"1 TΩ","cmc":"0,50 %"}],"parameters_cs":[{"name":"100 V až 1 kV","range":"1 GΩ","cmc":"0,030 %"},{"name":"100 V až 1 kV","range":"10 GΩ","cmc":"0,20 %"},{"name":"100 V až 1 kV","range":"100 GΩ","cmc":"0,40 %"},{"name":"100 V až 1 kV","range":"1 TΩ","cmc":"0,50 %"}],"technique":"Rezystor wzorcowy: pomiar bezpośredni lub porównanie","technique_en":"Standard resistor: direct measurement or comparison","technique_zh":"标准电阻：直接测量或比较","technique_cs":"Etalonový odpor: přímé měření nebo porovnání","techniques":["Rezystor wzorcowy: pomiar bezpośredni lub porównanie"],"techniques_en":["Standard resistor: direct measurement or comparison"],"techniques_zh":["标准电阻：直接测量或比较"],"techniques_cs":["Etalonový odpor: přímé měření nebo porovnání"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n100 V do 1 kV 1 GΩ CMC 0,030 %\n100 V do 1 kV 10 GΩ CMC 0,20 %\n100 V do 1 kV 100 GΩ CMC 0,40 %\n100 V do 1 kV 1 TΩ CMC 0,50 %\nRezystor wzorcowy: pomiar bezpośredni lub porównanie","reference":"MK13, MK14","norm_bases":["MK13","MK14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / teraomomierze, wzorce rezystancji Wzorcowanie – wielkości elektryczne Rezystor wzorcowy: pomiar bezpośredni lub porównanie 100 V do 1 kV 1 GΩ CMC 0,030 % 100 V do 1 kV 10 GΩ CMC 0,20 % 100 V do 1 kV 100 GΩ CMC 0,40 % 100 V do 1 kV 1 TΩ CMC 0,50 % Stejnosměrný odpor / Teraohmmetry, etalony odporu Kalibrace – elektrické veličiny Etalonový odpor: přímé měření nebo porovnání 100 V až 1 kV 1 GΩ CMC 0,030 % 100 V až 1 kV 10 GΩ CMC 0,20 % 100 V až 1 kV 100 GΩ CMC 0,40 % 100 V až 1 kV 1 TΩ CMC 0,50 % MK13, MK14 Rezystancja przy pradzie stalym / teraomomierze, wzorce rezystancji Wzorcowanie – wielkosci elektryczne Rezystor wzorcowy: pomiar bezposredni lub porownanie 100 V do 1 kV 1 GΩ CMC 0,030 % 100 V do 1 kV 10 GΩ CMC 0,20 % 100 V do 1 kV 100 GΩ CMC 0,40 % 100 V do 1 kV 1 TΩ CMC 0,50 % Stejnosmerny odpor / Teraohmmetry, etalony odporu Kalibrace – elektricke veliciny Etalonovy odpor: prime mereni nebo porovnani 100 V az 1 kV 1 GΩ CMC 0,030 % 100 V az 1 kV 10 GΩ CMC 0,20 % 100 V az 1 kV 100 GΩ CMC 0,40 % 100 V az 1 kV 1 TΩ CMC 0,50 % MK13, MK14","search_en":"DC resistance / Teraohmmeters, resistance standards Calibration – electrical quantities Standard resistor: direct measurement or comparison 100 V to 1 kV 1 GΩ CMC 0,030 % 100 V to 1 kV 10 GΩ CMC 0,20 % 100 V to 1 kV 100 GΩ CMC 0,40 % 100 V to 1 kV 1 TΩ CMC 0,50 % MK13, MK14","search_zh":"直流电阻 / 太欧表、电阻标准 校准 – 电学量 标准电阻：直接测量或比较 100 V 至 1 kV 1 GΩ CMC 0,030 % 100 V 至 1 kV 10 GΩ CMC 0,20 % 100 V 至 1 kV 100 GΩ CMC 0,40 % 100 V 至 1 kV 1 TΩ CMC 0,50 % MK13, MK14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d459789a7dd6b8acdcfd653f","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"14","test_object":"Rezystancja przy prądzie stałym / teraomomierze","test_object_en":"DC resistance / Teraohmmeters","test_object_zh":"直流电阻 / 太欧表","test_object_cs":"Stejnosměrný odpor / Teraohmmetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 V do 1 kV","range":"10 TΩ","cmc":"1,5 %"},{"name":"100 V do 1 kV","range":"100 TΩ","cmc":"3,0 %"}],"parameters_en":[{"name":"100 V to 1 kV","range":"10 TΩ","cmc":"1,5 %"},{"name":"100 V to 1 kV","range":"100 TΩ","cmc":"3,0 %"}],"parameters_zh":[{"name":"100 V 至 1 kV","range":"10 TΩ","cmc":"1,5 %"},{"name":"100 V 至 1 kV","range":"100 TΩ","cmc":"3,0 %"}],"parameters_cs":[{"name":"100 V až 1 kV","range":"10 TΩ","cmc":"1,5 %"},{"name":"100 V až 1 kV","range":"100 TΩ","cmc":"3,0 %"}],"technique":"Pomiar bezpośredni rezystora wzorcowego","technique_en":"Direct measurement of a standard resistor","technique_zh":"直接测量标准电阻","technique_cs":"Přímé měření etalonového odporu","techniques":["Pomiar bezpośredni rezystora wzorcowego"],"techniques_en":["Direct measurement of a standard resistor"],"techniques_zh":["直接测量标准电阻"],"techniques_cs":["Přímé měření etalonového odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n100 V do 1 kV 10 TΩ CMC 1,5 %\n100 V do 1 kV 100 TΩ CMC 3,0 %\nPomiar bezpośredni rezystora wzorcowego","reference":"MK14","norm_bases":["MK14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / teraomomierze Wzorcowanie – wielkości elektryczne Pomiar bezpośredni rezystora wzorcowego 100 V do 1 kV 10 TΩ CMC 1,5 % 100 V do 1 kV 100 TΩ CMC 3,0 % Stejnosměrný odpor / Teraohmmetry Kalibrace – elektrické veličiny Přímé měření etalonového odporu 100 V až 1 kV 10 TΩ CMC 1,5 % 100 V až 1 kV 100 TΩ CMC 3,0 % MK14 Rezystancja przy pradzie stalym / teraomomierze Wzorcowanie – wielkosci elektryczne Pomiar bezposredni rezystora wzorcowego 100 V do 1 kV 10 TΩ CMC 1,5 % 100 V do 1 kV 100 TΩ CMC 3,0 % Stejnosmerny odpor / Teraohmmetry Kalibrace – elektricke veliciny Prime mereni etalonoveho odporu 100 V az 1 kV 10 TΩ CMC 1,5 % 100 V az 1 kV 100 TΩ CMC 3,0 % MK14","search_en":"DC resistance / Teraohmmeters Calibration – electrical quantities Direct measurement of a standard resistor 100 V to 1 kV 10 TΩ CMC 1,5 % 100 V to 1 kV 100 TΩ CMC 3,0 % MK14","search_zh":"直流电阻 / 太欧表 校准 – 电学量 直接测量标准电阻 100 V 至 1 kV 10 TΩ CMC 1,5 % 100 V 至 1 kV 100 TΩ CMC 3,0 % MK14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f2fe140385fe9c7956bacc5","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"15","test_object":"Rezystancja przy prądzie przemiennym / mostki RLC, wzorce rezystancji przy prądzie przemiennym","test_object_en":"AC resistance / RLC bridges, AC resistance standards","test_object_zh":"交流电阻 / RLC 电桥、交流电阻标准","test_object_cs":"Střídavý odpor / RLC mosty, etalony střídavého odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"0,1 Ω","cmc":"0,50 %"},{"name":"1 kHz do 100 kHz","range":"0,1 Ω","cmc":"1,5 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,050 %"},{"name":"1 kHz do 1 MHz","range":"1 Ω","cmc":"0,10 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,030 %"},{"name":"1 kHz do 1 MHz","range":"10 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,030 %"},{"name":"1 kHz do 1 MHz","range":"100 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,030 %"},{"name":"1 kHz do 1 MHz","range":"1 kΩ","cmc":"0,050 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,030 %"},{"name":"1 kHz do 1 MHz","range":"10 kΩ","cmc":"0,10 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,030 %"},{"name":"1 kHz do 100 kHz","range":"100 kΩ","cmc":"0,10 %"}],"parameters_en":[{"name":"1 kHz","range":"0,1 Ω","cmc":"0,50 %"},{"name":"1 kHz to 100 kHz","range":"0,1 Ω","cmc":"1,5 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,050 %"},{"name":"1 kHz to 1 MHz","range":"1 Ω","cmc":"0,10 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,030 %"},{"name":"1 kHz to 1 MHz","range":"10 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,030 %"},{"name":"1 kHz to 1 MHz","range":"100 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,030 %"},{"name":"1 kHz to 1 MHz","range":"1 kΩ","cmc":"0,050 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,030 %"},{"name":"1 kHz to 1 MHz","range":"10 kΩ","cmc":"0,10 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,030 %"},{"name":"1 kHz to 100 kHz","range":"100 kΩ","cmc":"0,10 %"}],"parameters_zh":[{"name":"1 kHz","range":"0,1 Ω","cmc":"0,50 %"},{"name":"1 kHz 至 100 kHz","range":"0,1 Ω","cmc":"1,5 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,050 %"},{"name":"1 kHz 至 1 MHz","range":"1 Ω","cmc":"0,10 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,030 %"},{"name":"1 kHz 至 1 MHz","range":"10 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,030 %"},{"name":"1 kHz 至 1 MHz","range":"100 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,030 %"},{"name":"1 kHz 至 1 MHz","range":"1 kΩ","cmc":"0,050 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,030 %"},{"name":"1 kHz 至 1 MHz","range":"10 kΩ","cmc":"0,10 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,030 %"},{"name":"1 kHz 至 100 kHz","range":"100 kΩ","cmc":"0,10 %"}],"parameters_cs":[{"name":"1 kHz","range":"0,1 Ω","cmc":"0,50 %"},{"name":"1 kHz až 100 kHz","range":"0,1 Ω","cmc":"1,5 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,050 %"},{"name":"1 kHz až 1 MHz","range":"1 Ω","cmc":"0,10 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,030 %"},{"name":"1 kHz až 1 MHz","range":"10 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,030 %"},{"name":"1 kHz až 1 MHz","range":"100 Ω","cmc":"0,050 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,030 %"},{"name":"1 kHz až 1 MHz","range":"1 kΩ","cmc":"0,050 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,030 %"},{"name":"1 kHz až 1 MHz","range":"10 kΩ","cmc":"0,10 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,030 %"},{"name":"1 kHz až 100 kHz","range":"100 kΩ","cmc":"0,10 %"}],"technique":"Wzorce rezystancji przy prądzie przemiennym: pomiar bezpośredni lub porównanie","technique_en":"AC resistance standards: direct measurement or comparison","technique_zh":"交流电阻标准：直接测量或比较","technique_cs":"Etalony střídavého odporu: přímé měření nebo porovnání","techniques":["Wzorce rezystancji przy prądzie przemiennym: pomiar bezpośredni lub porównanie"],"techniques_en":["AC resistance standards: direct measurement or comparison"],"techniques_zh":["交流电阻标准：直接测量或比较"],"techniques_cs":["Etalony střídavého odporu: přímé měření nebo porovnání"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz 0,1 Ω CMC 0,50 %\n1 kHz do 100 kHz 0,1 Ω CMC 1,5 %\n1 kHz 1 Ω CMC 0,050 %\n1 kHz do 1 MHz 1 Ω CMC 0,10 %\n1 kHz 10 Ω CMC 0,030 %\n1 kHz do 1 MHz 10 Ω CMC 0,050 %\n1 kHz 100 Ω CMC 0,030 %\n1 kHz do 1 MHz 100 Ω CMC 0,050 %\n1 kHz 1 kΩ CMC 0,030 %\n1 kHz do 1 MHz 1 kΩ CMC 0,050 %\n1 kHz 10 kΩ CMC 0,030 %\n1 kHz do 1 MHz 10 kΩ CMC 0,10 %\n1 kHz 100 kΩ CMC 0,030 %\n1 kHz do 100 kHz 100 kΩ CMC 0,10 %\nWzorce rezystancji przy prądzie przemiennym: pomiar bezpośredni lub porównanie","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie przemiennym / mostki RLC, wzorce rezystancji przy prądzie przemiennym Wzorcowanie – wielkości elektryczne Wzorce rezystancji przy prądzie przemiennym: pomiar bezpośredni lub porównanie 1 kHz 0,1 Ω CMC 0,50 % 1 kHz do 100 kHz 0,1 Ω CMC 1,5 % 1 kHz 1 Ω CMC 0,050 % 1 kHz do 1 MHz 1 Ω CMC 0,10 % 1 kHz 10 Ω CMC 0,030 % 1 kHz do 1 MHz 10 Ω CMC 0,050 % 1 kHz 100 Ω CMC 0,030 % 1 kHz do 1 MHz 100 Ω CMC 0,050 % 1 kHz 1 kΩ CMC 0,030 % 1 kHz do 1 MHz 1 kΩ CMC 0,050 % 1 kHz 10 kΩ CMC 0,030 % 1 kHz do 1 MHz 10 kΩ CMC 0,10 % 1 kHz 100 kΩ CMC 0,030 % 1 kHz do 100 kHz 100 kΩ CMC 0,10 % Střídavý odpor / RLC mosty, etalony střídavého odporu Kalibrace – elektrické veličiny Etalony střídavého odporu: přímé měření nebo porovnání 1 kHz 0,1 Ω CMC 0,50 % 1 kHz až 100 kHz 0,1 Ω CMC 1,5 % 1 kHz 1 Ω CMC 0,050 % 1 kHz až 1 MHz 1 Ω CMC 0,10 % 1 kHz 10 Ω CMC 0,030 % 1 kHz až 1 MHz 10 Ω CMC 0,050 % 1 kHz 100 Ω CMC 0,030 % 1 kHz až 1 MHz 100 Ω CMC 0,050 % 1 kHz 1 kΩ CMC 0,030 % 1 kHz až 1 MHz 1 kΩ CMC 0,050 % 1 kHz 10 kΩ CMC 0,030 % 1 kHz až 1 MHz 10 kΩ CMC 0,10 % 1 kHz 100 kΩ CMC 0,030 % 1 kHz až 100 kHz 100 kΩ CMC 0,10 % MK15 Rezystancja przy pradzie przemiennym / mostki RLC, wzorce rezystancji przy pradzie przemiennym Wzorcowanie – wielkosci elektryczne Wzorce rezystancji przy pradzie przemiennym: pomiar bezposredni lub porownanie 1 kHz 0,1 Ω CMC 0,50 % 1 kHz do 100 kHz 0,1 Ω CMC 1,5 % 1 kHz 1 Ω CMC 0,050 % 1 kHz do 1 MHz 1 Ω CMC 0,10 % 1 kHz 10 Ω CMC 0,030 % 1 kHz do 1 MHz 10 Ω CMC 0,050 % 1 kHz 100 Ω CMC 0,030 % 1 kHz do 1 MHz 100 Ω CMC 0,050 % 1 kHz 1 kΩ CMC 0,030 % 1 kHz do 1 MHz 1 kΩ CMC 0,050 % 1 kHz 10 kΩ CMC 0,030 % 1 kHz do 1 MHz 10 kΩ CMC 0,10 % 1 kHz 100 kΩ CMC 0,030 % 1 kHz do 100 kHz 100 kΩ CMC 0,10 % Stridavy odpor / RLC mosty, etalony stridaveho odporu Kalibrace – elektricke veliciny Etalony stridaveho odporu: prime mereni nebo porovnani 1 kHz 0,1 Ω CMC 0,50 % 1 kHz az 100 kHz 0,1 Ω CMC 1,5 % 1 kHz 1 Ω CMC 0,050 % 1 kHz az 1 MHz 1 Ω CMC 0,10 % 1 kHz 10 Ω CMC 0,030 % 1 kHz az 1 MHz 10 Ω CMC 0,050 % 1 kHz 100 Ω CMC 0,030 % 1 kHz az 1 MHz 100 Ω CMC 0,050 % 1 kHz 1 kΩ CMC 0,030 % 1 kHz az 1 MHz 1 kΩ CMC 0,050 % 1 kHz 10 kΩ CMC 0,030 % 1 kHz az 1 MHz 10 kΩ CMC 0,10 % 1 kHz 100 kΩ CMC 0,030 % 1 kHz az 100 kHz 100 kΩ CMC 0,10 % MK15","search_en":"AC resistance / RLC bridges, AC resistance standards Calibration – electrical quantities AC resistance standards: direct measurement or comparison 1 kHz 0,1 Ω CMC 0,50 % 1 kHz to 100 kHz 0,1 Ω CMC 1,5 % 1 kHz 1 Ω CMC 0,050 % 1 kHz to 1 MHz 1 Ω CMC 0,10 % 1 kHz 10 Ω CMC 0,030 % 1 kHz to 1 MHz 10 Ω CMC 0,050 % 1 kHz 100 Ω CMC 0,030 % 1 kHz to 1 MHz 100 Ω CMC 0,050 % 1 kHz 1 kΩ CMC 0,030 % 1 kHz to 1 MHz 1 kΩ CMC 0,050 % 1 kHz 10 kΩ CMC 0,030 % 1 kHz to 1 MHz 10 kΩ CMC 0,10 % 1 kHz 100 kΩ CMC 0,030 % 1 kHz to 100 kHz 100 kΩ CMC 0,10 % MK15","search_zh":"交流电阻 / RLC 电桥、交流电阻标准 校准 – 电学量 交流电阻标准：直接测量或比较 1 kHz 0,1 Ω CMC 0,50 % 1 kHz 至 100 kHz 0,1 Ω CMC 1,5 % 1 kHz 1 Ω CMC 0,050 % 1 kHz 至 1 MHz 1 Ω CMC 0,10 % 1 kHz 10 Ω CMC 0,030 % 1 kHz 至 1 MHz 10 Ω CMC 0,050 % 1 kHz 100 Ω CMC 0,030 % 1 kHz 至 1 MHz 100 Ω CMC 0,050 % 1 kHz 1 kΩ CMC 0,030 % 1 kHz 至 1 MHz 1 kΩ CMC 0,050 % 1 kHz 10 kΩ CMC 0,030 % 1 kHz 至 1 MHz 10 kΩ CMC 0,10 % 1 kHz 100 kΩ CMC 0,030 % 1 kHz 至 100 kHz 100 kΩ CMC 0,10 % MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fca228e6bac7367edf5a1cd8","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"16","test_object":"Impedancja sieci / mierniki impedancji sieci","test_object_en":"Network impedance / Network impedance meters","test_object_zh":"电网阻抗 / 电网阻抗测量仪","test_object_cs":"Impedance sítě / Měřidla impedance sítě","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 0,5 Ω do 20 kΩ","cmc":"0,10 % + 50 mΩ"}],"parameters_en":[{"name":"50 Hz","range":"0,5 Ω to 20 kΩ","cmc":"0,10 % + 50 mΩ"}],"parameters_zh":[{"name":"50 Hz","range":"0,5 Ω 至 20 kΩ","cmc":"0,10 % + 50 mΩ"}],"parameters_cs":[{"name":"50 Hz","range":"0,5 Ω až 20 kΩ","cmc":"0,10 % + 50 mΩ"}],"technique":"Pomiar skalibrowanego gniazda połączonego szeregowo z dekadą rezystancyjną","technique_en":"Measurement of a calibrated socket in series with a resistance decade","technique_zh":"测量与电阻箱串联的已校准插座","technique_cs":"Měření kalibrované zásuvky v sérii s odporovou dekádou","techniques":["Pomiar skalibrowanego gniazda połączonego szeregowo z dekadą rezystancyjną"],"techniques_en":["Measurement of a calibrated socket in series with a resistance decade"],"techniques_zh":["测量与电阻箱串联的已校准插座"],"techniques_cs":["Měření kalibrované zásuvky v sérii s odporovou dekádou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 0,5 Ω do 20 kΩ CMC 0,10 % + 50 mΩ\nPomiar skalibrowanego gniazda połączonego szeregowo z dekadą rezystancyjną","reference":"MK11","norm_bases":["MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja sieci / mierniki impedancji sieci Wzorcowanie – wielkości elektryczne Pomiar skalibrowanego gniazda połączonego szeregowo z dekadą rezystancyjną 50 Hz od 0,5 Ω do 20 kΩ CMC 0,10 % + 50 mΩ Impedance sítě / Měřidla impedance sítě Kalibrace – elektrické veličiny Měření kalibrované zásuvky v sérii s odporovou dekádou 50 Hz 0,5 Ω až 20 kΩ CMC 0,10 % + 50 mΩ MK11 Impedancja sieci / mierniki impedancji sieci Wzorcowanie – wielkosci elektryczne Pomiar skalibrowanego gniazda polaczonego szeregowo z dekada rezystancyjna 50 Hz od 0,5 Ω do 20 kΩ CMC 0,10 % + 50 mΩ Impedance site / Meridla impedance site Kalibrace – elektricke veliciny Mereni kalibrovane zasuvky v serii s odporovou dekadou 50 Hz 0,5 Ω az 20 kΩ CMC 0,10 % + 50 mΩ MK11","search_en":"Network impedance / Network impedance meters Calibration – electrical quantities Measurement of a calibrated socket in series with a resistance decade 50 Hz 0,5 Ω to 20 kΩ CMC 0,10 % + 50 mΩ MK11","search_zh":"电网阻抗 / 电网阻抗测量仪 校准 – 电学量 测量与电阻箱串联的已校准插座 50 Hz 0,5 Ω 至 20 kΩ CMC 0,10 % + 50 mΩ MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2bd2ddbc40696c85f8557218","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"17","test_object":"Rezystancja przejścia przy prądzie przemiennym / mierniki rezystancji przejścia","test_object_en":"AC contact resistance / Contact resistance meters","test_object_zh":"交流接触电阻 / 接触电阻测量仪","test_object_cs":"Střídavý přechodový odpor / Měřidla přechodového odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"1 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"10 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"100 mΩ","cmc":"0,10 %"}],"parameters_en":[{"name":"50 Hz","range":"1 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"10 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"100 mΩ","cmc":"0,10 %"}],"parameters_zh":[{"name":"50 Hz","range":"1 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"10 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"100 mΩ","cmc":"0,10 %"}],"parameters_cs":[{"name":"50 Hz","range":"1 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"10 mΩ","cmc":"0,10 %"},{"name":"50 Hz","range":"100 mΩ","cmc":"0,10 %"}],"technique":"Pomiar bezpośredni wzorca rezystancji przejścia","technique_en":"Direct measurement of a contact resistance standard","technique_zh":"直接测量接触电阻标准","technique_cs":"Přímé měření etalonu přechodového odporu","techniques":["Pomiar bezpośredni wzorca rezystancji przejścia"],"techniques_en":["Direct measurement of a contact resistance standard"],"techniques_zh":["直接测量接触电阻标准"],"techniques_cs":["Přímé měření etalonu přechodového odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz 1 mΩ CMC 0,10 %\n50 Hz 10 mΩ CMC 0,10 %\n50 Hz 100 mΩ CMC 0,10 %\nPomiar bezpośredni wzorca rezystancji przejścia","reference":"MK11","norm_bases":["MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przejścia przy prądzie przemiennym / mierniki rezystancji przejścia Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorca rezystancji przejścia 50 Hz 1 mΩ CMC 0,10 % 50 Hz 10 mΩ CMC 0,10 % 50 Hz 100 mΩ CMC 0,10 % Střídavý přechodový odpor / Měřidla přechodového odporu Kalibrace – elektrické veličiny Přímé měření etalonu přechodového odporu 50 Hz 1 mΩ CMC 0,10 % 50 Hz 10 mΩ CMC 0,10 % 50 Hz 100 mΩ CMC 0,10 % MK11 Rezystancja przejscia przy pradzie przemiennym / mierniki rezystancji przejscia Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorca rezystancji przejscia 50 Hz 1 mΩ CMC 0,10 % 50 Hz 10 mΩ CMC 0,10 % 50 Hz 100 mΩ CMC 0,10 % Stridavy prechodovy odpor / Meridla prechodoveho odporu Kalibrace – elektricke veliciny Prime mereni etalonu prechodoveho odporu 50 Hz 1 mΩ CMC 0,10 % 50 Hz 10 mΩ CMC 0,10 % 50 Hz 100 mΩ CMC 0,10 % MK11","search_en":"AC contact resistance / Contact resistance meters Calibration – electrical quantities Direct measurement of a contact resistance standard 50 Hz 1 mΩ CMC 0,10 % 50 Hz 10 mΩ CMC 0,10 % 50 Hz 100 mΩ CMC 0,10 % MK11","search_zh":"交流接触电阻 / 接触电阻测量仪 校准 – 电学量 直接测量接触电阻标准 50 Hz 1 mΩ CMC 0,10 % 50 Hz 10 mΩ CMC 0,10 % 50 Hz 100 mΩ CMC 0,10 % MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d5436b9ef53d6a0a261de89","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"18","test_object":"Pojemność / wzorce pojemności","test_object_en":"Capacitance / Capacitance standards","test_object_zh":"电容 / 电容标准","test_object_cs":"Kapacita / Etalony kapacity","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz do 1 MHz","range":"od 1 pF do 10 pF","cmc":"0,30 %"},{"name":"1 kHz do 1 MHz","range":"od 10 pF do 1 nF","cmc":"0,20 %"}],"parameters_en":[{"name":"1 kHz to 1 MHz","range":"1 pF to 10 pF","cmc":"0,30 %"},{"name":"1 kHz to 1 MHz","range":"10 pF to 1 nF","cmc":"0,20 %"}],"parameters_zh":[{"name":"1 kHz 至 1 MHz","range":"1 pF 至 10 pF","cmc":"0,30 %"},{"name":"1 kHz 至 1 MHz","range":"10 pF 至 1 nF","cmc":"0,20 %"}],"parameters_cs":[{"name":"1 kHz až 1 MHz","range":"1 pF až 10 pF","cmc":"0,30 %"},{"name":"1 kHz až 1 MHz","range":"10 pF až 1 nF","cmc":"0,20 %"}],"technique":"Pomiar bezpośredni wzorcowym mostkiem RLC","technique_en":"Direct measurement by a standard RLC bridge","technique_zh":"用标准 RLC 电桥直接测量","technique_cs":"Přímé měřeni etalonovým RLC mostem","techniques":["Pomiar bezpośredni wzorcowym mostkiem RLC"],"techniques_en":["Direct measurement by a standard RLC bridge"],"techniques_zh":["用标准 RLC 电桥直接测量"],"techniques_cs":["Přímé měřeni etalonovým RLC mostem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz do 1 MHz od 1 pF do 10 pF CMC 0,30 %\n1 kHz do 1 MHz od 10 pF do 1 nF CMC 0,20 %\nPomiar bezpośredni wzorcowym mostkiem RLC","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / wzorce pojemności Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowym mostkiem RLC 1 kHz do 1 MHz od 1 pF do 10 pF CMC 0,30 % 1 kHz do 1 MHz od 10 pF do 1 nF CMC 0,20 % Kapacita / Etalony kapacity Kalibrace – elektrické veličiny Přímé měřeni etalonovým RLC mostem 1 kHz až 1 MHz 1 pF až 10 pF CMC 0,30 % 1 kHz až 1 MHz 10 pF až 1 nF CMC 0,20 % MK15 Pojemnosc / wzorce pojemnosci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowym mostkiem RLC 1 kHz do 1 MHz od 1 pF do 10 pF CMC 0,30 % 1 kHz do 1 MHz od 10 pF do 1 nF CMC 0,20 % Kapacita / Etalony kapacity Kalibrace – elektricke veliciny Prime mereni etalonovym RLC mostem 1 kHz az 1 MHz 1 pF az 10 pF CMC 0,30 % 1 kHz az 1 MHz 10 pF az 1 nF CMC 0,20 % MK15","search_en":"Capacitance / Capacitance standards Calibration – electrical quantities Direct measurement by a standard RLC bridge 1 kHz to 1 MHz 1 pF to 10 pF CMC 0,30 % 1 kHz to 1 MHz 10 pF to 1 nF CMC 0,20 % MK15","search_zh":"电容 / 电容标准 校准 – 电学量 用标准 RLC 电桥直接测量 1 kHz 至 1 MHz 1 pF 至 10 pF CMC 0,30 % 1 kHz 至 1 MHz 10 pF 至 1 nF CMC 0,20 % MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"71fbec788a2d9f6c1233ecf4","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"18","test_object":"Pojemność / mostki RLC, wzorce pojemności","test_object_en":"Capacitance / RLC bridges, capacitance standards","test_object_zh":"电容 / RLC 电桥、电容标准","test_object_cs":"Kapacita / RLC mosty, etalony kapacity","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"1 pF","cmc":"0,050 %"},{"name":"1 kHz do 1 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,030 %"},{"name":"1 kHz do 1 MHz","range":"10 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,030 %"},{"name":"1 kHz do 1 MHz","range":"100 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz do 1 MHz","range":"1 nF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,030 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,030 %"},{"name":"100 Hz do 1 kHz","range":"1 µF","cmc":"0,030 %"}],"parameters_en":[{"name":"1 kHz","range":"1 pF","cmc":"0,050 %"},{"name":"1 kHz to 1 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,030 %"},{"name":"1 kHz to 1 MHz","range":"10 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,030 %"},{"name":"1 kHz to 1 MHz","range":"100 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz to 1 MHz","range":"1 nF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,030 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,030 %"},{"name":"100 Hz to 1 kHz","range":"1 µF","cmc":"0,030 %"}],"parameters_zh":[{"name":"1 kHz","range":"1 pF","cmc":"0,050 %"},{"name":"1 kHz 至 1 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,030 %"},{"name":"1 kHz 至 1 MHz","range":"10 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,030 %"},{"name":"1 kHz 至 1 MHz","range":"100 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz 至 1 MHz","range":"1 nF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,030 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,030 %"},{"name":"100 Hz 至 1 kHz","range":"1 µF","cmc":"0,030 %"}],"parameters_cs":[{"name":"1 kHz","range":"1 pF","cmc":"0,050 %"},{"name":"1 kHz až 1 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,030 %"},{"name":"1 kHz až 1 MHz","range":"10 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,030 %"},{"name":"1 kHz až 1 MHz","range":"100 pF","cmc":"0,10 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz až 1 MHz","range":"1 nF","cmc":"0,10 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,030 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,030 %"},{"name":"100 Hz až 1 kHz","range":"1 µF","cmc":"0,030 %"}],"technique":"Wzorce pojemności: pomiar bezpośredni lub porównanie","technique_en":"Capacitance standards: direct measurement or comparison","technique_zh":"电容标准：直接测量或比较","technique_cs":"Etalony kapacity: přímé měření nebo porovnání","techniques":["Wzorce pojemności: pomiar bezpośredni lub porównanie"],"techniques_en":["Capacitance standards: direct measurement or comparison"],"techniques_zh":["电容标准：直接测量或比较"],"techniques_cs":["Etalony kapacity: přímé měření nebo porovnání"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz 1 pF CMC 0,050 %\n1 kHz do 1 MHz 1 pF CMC 0,10 %\n1 kHz 10 pF CMC 0,030 %\n1 kHz do 1 MHz 10 pF CMC 0,10 %\n1 kHz 100 pF CMC 0,030 %\n1 kHz do 1 MHz 100 pF CMC 0,10 %\n1 kHz 1 nF CMC 0,030 %\n1 kHz do 1 MHz 1 nF CMC 0,10 %\n1 kHz 10 nF CMC 0,030 %\n1 kHz 100 nF CMC 0,030 %\n100 Hz do 1 kHz 1 µF CMC 0,030 %\nWzorce pojemności: pomiar bezpośredni lub porównanie","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / mostki RLC, wzorce pojemności Wzorcowanie – wielkości elektryczne Wzorce pojemności: pomiar bezpośredni lub porównanie 1 kHz 1 pF CMC 0,050 % 1 kHz do 1 MHz 1 pF CMC 0,10 % 1 kHz 10 pF CMC 0,030 % 1 kHz do 1 MHz 10 pF CMC 0,10 % 1 kHz 100 pF CMC 0,030 % 1 kHz do 1 MHz 100 pF CMC 0,10 % 1 kHz 1 nF CMC 0,030 % 1 kHz do 1 MHz 1 nF CMC 0,10 % 1 kHz 10 nF CMC 0,030 % 1 kHz 100 nF CMC 0,030 % 100 Hz do 1 kHz 1 µF CMC 0,030 % Kapacita / RLC mosty, etalony kapacity Kalibrace – elektrické veličiny Etalony kapacity: přímé měření nebo porovnání 1 kHz 1 pF CMC 0,050 % 1 kHz až 1 MHz 1 pF CMC 0,10 % 1 kHz 10 pF CMC 0,030 % 1 kHz až 1 MHz 10 pF CMC 0,10 % 1 kHz 100 pF CMC 0,030 % 1 kHz až 1 MHz 100 pF CMC 0,10 % 1 kHz 1 nF CMC 0,030 % 1 kHz až 1 MHz 1 nF CMC 0,10 % 1 kHz 10 nF CMC 0,030 % 1 kHz 100 nF CMC 0,030 % 100 Hz až 1 kHz 1 µF CMC 0,030 % MK15 Pojemnosc / mostki RLC, wzorce pojemnosci Wzorcowanie – wielkosci elektryczne Wzorce pojemnosci: pomiar bezposredni lub porownanie 1 kHz 1 pF CMC 0,050 % 1 kHz do 1 MHz 1 pF CMC 0,10 % 1 kHz 10 pF CMC 0,030 % 1 kHz do 1 MHz 10 pF CMC 0,10 % 1 kHz 100 pF CMC 0,030 % 1 kHz do 1 MHz 100 pF CMC 0,10 % 1 kHz 1 nF CMC 0,030 % 1 kHz do 1 MHz 1 nF CMC 0,10 % 1 kHz 10 nF CMC 0,030 % 1 kHz 100 nF CMC 0,030 % 100 Hz do 1 kHz 1 µF CMC 0,030 % Kapacita / RLC mosty, etalony kapacity Kalibrace – elektricke veliciny Etalony kapacity: prime mereni nebo porovnani 1 kHz 1 pF CMC 0,050 % 1 kHz az 1 MHz 1 pF CMC 0,10 % 1 kHz 10 pF CMC 0,030 % 1 kHz az 1 MHz 10 pF CMC 0,10 % 1 kHz 100 pF CMC 0,030 % 1 kHz az 1 MHz 100 pF CMC 0,10 % 1 kHz 1 nF CMC 0,030 % 1 kHz az 1 MHz 1 nF CMC 0,10 % 1 kHz 10 nF CMC 0,030 % 1 kHz 100 nF CMC 0,030 % 100 Hz az 1 kHz 1 µF CMC 0,030 % MK15","search_en":"Capacitance / RLC bridges, capacitance standards Calibration – electrical quantities Capacitance standards: direct measurement or comparison 1 kHz 1 pF CMC 0,050 % 1 kHz to 1 MHz 1 pF CMC 0,10 % 1 kHz 10 pF CMC 0,030 % 1 kHz to 1 MHz 10 pF CMC 0,10 % 1 kHz 100 pF CMC 0,030 % 1 kHz to 1 MHz 100 pF CMC 0,10 % 1 kHz 1 nF CMC 0,030 % 1 kHz to 1 MHz 1 nF CMC 0,10 % 1 kHz 10 nF CMC 0,030 % 1 kHz 100 nF CMC 0,030 % 100 Hz to 1 kHz 1 µF CMC 0,030 % MK15","search_zh":"电容 / RLC 电桥、电容标准 校准 – 电学量 电容标准：直接测量或比较 1 kHz 1 pF CMC 0,050 % 1 kHz 至 1 MHz 1 pF CMC 0,10 % 1 kHz 10 pF CMC 0,030 % 1 kHz 至 1 MHz 10 pF CMC 0,10 % 1 kHz 100 pF CMC 0,030 % 1 kHz 至 1 MHz 100 pF CMC 0,10 % 1 kHz 1 nF CMC 0,030 % 1 kHz 至 1 MHz 1 nF CMC 0,10 % 1 kHz 10 nF CMC 0,030 % 1 kHz 100 nF CMC 0,030 % 100 Hz 至 1 kHz 1 µF CMC 0,030 % MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf65546ffbdccc5e9f0f5152","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"19","test_object":"Pojemność / mostki RLC, wzorce pojemności, multimetry","test_object_en":"Capacitance / RLC bridges, capacitance standards, multimeters","test_object_zh":"电容 / RLC 电桥、电容标准、万用表","test_object_cs":"Kapacita / RLC mosty, etalony kapacity, multimetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"od 1 nF do 1 µF","cmc":"0,10 %"},{"name":"100 Hz do 1 kHz","range":"od 1 µF do 100 µF","cmc":"0,10 %"}],"parameters_en":[{"name":"1 kHz","range":"1 nF to 1 µF","cmc":"0,10 %"},{"name":"100 Hz to 1 kHz","range":"1 µF to 100 µF","cmc":"0,10 %"}],"parameters_zh":[{"name":"1 kHz","range":"1 nF 至 1 µF","cmc":"0,10 %"},{"name":"100 Hz 至 1 kHz","range":"1 µF 至 100 µF","cmc":"0,10 %"}],"parameters_cs":[{"name":"1 kHz","range":"1 nF až 1 µF","cmc":"0,10 %"},{"name":"100 Hz až 1 kHz","range":"1 µF až 100 µF","cmc":"0,10 %"}],"technique":"Wzorcowe dekady pojemnościowe: pomiar bezpośredni lub porównanie","technique_en":"Standard capacitance decades: direct measurement or comparison","technique_zh":"标准电容箱：直接测量或比较","technique_cs":"Etalonové kapacitní dekády: přímé měření nebo porovnání","techniques":["Wzorcowe dekady pojemnościowe: pomiar bezpośredni lub porównanie"],"techniques_en":["Standard capacitance decades: direct measurement or comparison"],"techniques_zh":["标准电容箱：直接测量或比较"],"techniques_cs":["Etalonové kapacitní dekády: přímé měření nebo porovnání"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz od 1 nF do 1 µF CMC 0,10 %\n100 Hz do 1 kHz od 1 µF do 100 µF CMC 0,10 %\nWzorcowe dekady pojemnościowe: pomiar bezpośredni lub porównanie","reference":"MK8, MK15","norm_bases":["MK8","MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / mostki RLC, wzorce pojemności, multimetry Wzorcowanie – wielkości elektryczne Wzorcowe dekady pojemnościowe: pomiar bezpośredni lub porównanie 1 kHz od 1 nF do 1 µF CMC 0,10 % 100 Hz do 1 kHz od 1 µF do 100 µF CMC 0,10 % Kapacita / RLC mosty, etalony kapacity, multimetry Kalibrace – elektrické veličiny Etalonové kapacitní dekády: přímé měření nebo porovnání 1 kHz 1 nF až 1 µF CMC 0,10 % 100 Hz až 1 kHz 1 µF až 100 µF CMC 0,10 % MK8, MK15 Pojemnosc / mostki RLC, wzorce pojemnosci, multimetry Wzorcowanie – wielkosci elektryczne Wzorcowe dekady pojemnosciowe: pomiar bezposredni lub porownanie 1 kHz od 1 nF do 1 µF CMC 0,10 % 100 Hz do 1 kHz od 1 µF do 100 µF CMC 0,10 % Kapacita / RLC mosty, etalony kapacity, multimetry Kalibrace – elektricke veliciny Etalonove kapacitni dekady: prime mereni nebo porovnani 1 kHz 1 nF az 1 µF CMC 0,10 % 100 Hz az 1 kHz 1 µF az 100 µF CMC 0,10 % MK8, MK15","search_en":"Capacitance / RLC bridges, capacitance standards, multimeters Calibration – electrical quantities Standard capacitance decades: direct measurement or comparison 1 kHz 1 nF to 1 µF CMC 0,10 % 100 Hz to 1 kHz 1 µF to 100 µF CMC 0,10 % MK8, MK15","search_zh":"电容 / RLC 电桥、电容标准、万用表 校准 – 电学量 标准电容箱：直接测量或比较 1 kHz 1 nF 至 1 µF CMC 0,10 % 100 Hz 至 1 kHz 1 µF 至 100 µF CMC 0,10 % MK8, MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e65a76f71cb69636dbee14ab","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"20","test_object":"Współczynnik strat pojemności / mostki RLC, wzorce pojemności, dekady pojemnościowe","test_object_en":"Capacitance dissipation factor / RLC bridges, capacitance standards, capacitance decades","test_object_zh":"电容损耗因数 / RLC 电桥、电容标准、电容箱","test_object_cs":"Ztrátový činitel kapacity / RLC mosty, etalony kapacity, kapacitní dekády","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 pF do 100 pF; 1 kHz","range":"od 0,00 do 0,01","cmc":"2,0 % + 0,0010 (abs.)"},{"name":"1 pF; 10 kHz do 1 MHz","range":"od 0,00 do 1,6","cmc":"0,60 % + 0,0017 (abs.)"},{"name":"10 pF do 1 nF; 10 kHz do 1 MHz","range":"od 0,00 do 1,6","cmc":"0,40 % + 0,0010 (abs.)"},{"name":"1 nF; 1 kHz","range":"od 0,00 do 1,6","cmc":"1,0 % + 0,0010 (abs.)"},{"name":"10 nF do 1 µF; 1 kHz","range":"od 0,00 do 1,6","cmc":"0,50 % + 0,0005 (abs.)"}],"parameters_en":[{"name":"1 pF to 100 pF; 1 kHz","range":"0,00 to 0,01","cmc":"2,0 % + 0,0010 (abs.)"},{"name":"1 pF; 10 kHz to 1 MHz","range":"0,00 to 1,6","cmc":"0,60 % + 0,0017 (abs.)"},{"name":"10 pF to 1 nF; 10 kHz to 1 MHz","range":"0,00 to 1,6","cmc":"0,40 % + 0,0010 (abs.)"},{"name":"1 nF; 1 kHz","range":"0,00 to 1,6","cmc":"1,0 % + 0,0010 (abs.)"},{"name":"10 nF to 1 µF; 1 kHz","range":"0,00 to 1,6","cmc":"0,50 % + 0,0005 (abs.)"}],"parameters_zh":[{"name":"1 pF 至 100 pF；1 kHz","range":"0,00 至 0,01","cmc":"2,0 % + 0,0010 (abs.)"},{"name":"1 pF；10 kHz 至 1 MHz","range":"0,00 至 1,6","cmc":"0,60 % + 0,0017 (abs.)"},{"name":"10 pF 至 1 nF；10 kHz 至 1 MHz","range":"0,00 至 1,6","cmc":"0,40 % + 0,0010 (abs.)"},{"name":"1 nF; 1 kHz","range":"0,00 至 1,6","cmc":"1,0 % + 0,0010 (abs.)"},{"name":"10 nF 至 1 µF；1 kHz","range":"0,00 至 1,6","cmc":"0,50 % + 0,0005 (abs.)"}],"parameters_cs":[{"name":"1 pF až 100 pF; 1 kHz","range":"0,00 až 0,01","cmc":"2,0 % + 0,0010 (abs.)"},{"name":"1 pF; 10 kHz až 1 MHz","range":"0,00 až 1,6","cmc":"0,60 % + 0,0017 (abs.)"},{"name":"10 pF až 1 nF; 10 kHz až 1 MHz","range":"0,00 až 1,6","cmc":"0,40 % + 0,0010 (abs.)"},{"name":"1 nF; 1 kHz","range":"0,00 až 1,6","cmc":"1,0 % + 0,0010 (abs.)"},{"name":"10 nF až 1 µF; 1 kHz","range":"0,00 až 1,6","cmc":"0,50 % + 0,0005 (abs.)"}],"technique":"Pomiar równoległego połączenia pojemności i rezystancji przy prądzie przemiennym lub pomiar bezpośredni wzorcowym mostkiem RLC","technique_en":"Measurement of a parallel combination of capacitance and AC resistance or direct measurement by a standard RLC bridge","technique_zh":"测量电容与交流电阻的并联组合，或用标准 RLC 电桥直接测量","technique_cs":"Měření paralelní kombinace kapacity a střídavého odporu nebo přímé měření etalonovým RLC mostem","techniques":["Pomiar równoległego połączenia pojemności i rezystancji przy prądzie przemiennym lub pomiar bezpośredni wzorcowym mostkiem RLC"],"techniques_en":["Measurement of a parallel combination of capacitance and AC resistance or direct measurement by a standard RLC bridge"],"techniques_zh":["测量电容与交流电阻的并联组合，或用标准 RLC 电桥直接测量"],"techniques_cs":["Měření paralelní kombinace kapacity a střídavého odporu nebo přímé měření etalonovým RLC mostem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 pF do 100 pF; 1 kHz od 0,00 do 0,01 CMC 2,0 % + 0,0010 (abs.)\n1 pF; 10 kHz do 1 MHz od 0,00 do 1,6 CMC 0,60 % + 0,0017 (abs.)\n10 pF do 1 nF; 10 kHz do 1 MHz od 0,00 do 1,6 CMC 0,40 % + 0,0010 (abs.)\n1 nF; 1 kHz od 0,00 do 1,6 CMC 1,0 % + 0,0010 (abs.)\n10 nF do 1 µF; 1 kHz od 0,00 do 1,6 CMC 0,50 % + 0,0005 (abs.)\nPomiar równoległego połączenia pojemności i rezystancji przy prądzie przemiennym lub pomiar bezpośredni wzorcowym mostkiem RLC","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik strat pojemności / mostki RLC, wzorce pojemności, dekady pojemnościowe Wzorcowanie – wielkości elektryczne Pomiar równoległego połączenia pojemności i rezystancji przy prądzie przemiennym lub pomiar bezpośredni wzorcowym mostkiem RLC 1 pF do 100 pF; 1 kHz od 0,00 do 0,01 CMC 2,0 % + 0,0010 (abs.) 1 pF; 10 kHz do 1 MHz od 0,00 do 1,6 CMC 0,60 % + 0,0017 (abs.) 10 pF do 1 nF; 10 kHz do 1 MHz od 0,00 do 1,6 CMC 0,40 % + 0,0010 (abs.) 1 nF; 1 kHz od 0,00 do 1,6 CMC 1,0 % + 0,0010 (abs.) 10 nF do 1 µF; 1 kHz od 0,00 do 1,6 CMC 0,50 % + 0,0005 (abs.) Ztrátový činitel kapacity / RLC mosty, etalony kapacity, kapacitní dekády Kalibrace – elektrické veličiny Měření paralelní kombinace kapacity a střídavého odporu nebo přímé měření etalonovým RLC mostem 1 pF až 100 pF; 1 kHz 0,00 až 0,01 CMC 2,0 % + 0,0010 (abs.) 1 pF; 10 kHz až 1 MHz 0,00 až 1,6 CMC 0,60 % + 0,0017 (abs.) 10 pF až 1 nF; 10 kHz až 1 MHz 0,00 až 1,6 CMC 0,40 % + 0,0010 (abs.) 1 nF; 1 kHz 0,00 až 1,6 CMC 1,0 % + 0,0010 (abs.) 10 nF až 1 µF; 1 kHz 0,00 až 1,6 CMC 0,50 % + 0,0005 (abs.) MK15 Wspolczynnik strat pojemnosci / mostki RLC, wzorce pojemnosci, dekady pojemnosciowe Wzorcowanie – wielkosci elektryczne Pomiar rownoleglego polaczenia pojemnosci i rezystancji przy pradzie przemiennym lub pomiar bezposredni wzorcowym mostkiem RLC 1 pF do 100 pF; 1 kHz od 0,00 do 0,01 CMC 2,0 % + 0,0010 (abs.) 1 pF; 10 kHz do 1 MHz od 0,00 do 1,6 CMC 0,60 % + 0,0017 (abs.) 10 pF do 1 nF; 10 kHz do 1 MHz od 0,00 do 1,6 CMC 0,40 % + 0,0010 (abs.) 1 nF; 1 kHz od 0,00 do 1,6 CMC 1,0 % + 0,0010 (abs.) 10 nF do 1 µF; 1 kHz od 0,00 do 1,6 CMC 0,50 % + 0,0005 (abs.) Ztratovy cinitel kapacity / RLC mosty, etalony kapacity, kapacitni dekady Kalibrace – elektricke veliciny Mereni paralelni kombinace kapacity a stridaveho odporu nebo prime mereni etalonovym RLC mostem 1 pF az 100 pF; 1 kHz 0,00 az 0,01 CMC 2,0 % + 0,0010 (abs.) 1 pF; 10 kHz az 1 MHz 0,00 az 1,6 CMC 0,60 % + 0,0017 (abs.) 10 pF az 1 nF; 10 kHz az 1 MHz 0,00 az 1,6 CMC 0,40 % + 0,0010 (abs.) 1 nF; 1 kHz 0,00 az 1,6 CMC 1,0 % + 0,0010 (abs.) 10 nF az 1 µF; 1 kHz 0,00 az 1,6 CMC 0,50 % + 0,0005 (abs.) MK15","search_en":"Capacitance dissipation factor / RLC bridges, capacitance standards, capacitance decades Calibration – electrical quantities Measurement of a parallel combination of capacitance and AC resistance or direct measurement by a standard RLC bridge 1 pF to 100 pF; 1 kHz 0,00 to 0,01 CMC 2,0 % + 0,0010 (abs.) 1 pF; 10 kHz to 1 MHz 0,00 to 1,6 CMC 0,60 % + 0,0017 (abs.) 10 pF to 1 nF; 10 kHz to 1 MHz 0,00 to 1,6 CMC 0,40 % + 0,0010 (abs.) 1 nF; 1 kHz 0,00 to 1,6 CMC 1,0 % + 0,0010 (abs.) 10 nF to 1 µF; 1 kHz 0,00 to 1,6 CMC 0,50 % + 0,0005 (abs.) MK15","search_zh":"电容损耗因数 / RLC 电桥、电容标准、电容箱 校准 – 电学量 测量电容与交流电阻的并联组合，或用标准 RLC 电桥直接测量 1 pF 至 100 pF；1 kHz 0,00 至 0,01 CMC 2,0 % + 0,0010 (abs.) 1 pF；10 kHz 至 1 MHz 0,00 至 1,6 CMC 0,60 % + 0,0017 (abs.) 10 pF 至 1 nF；10 kHz 至 1 MHz 0,00 至 1,6 CMC 0,40 % + 0,0010 (abs.) 1 nF; 1 kHz 0,00 至 1,6 CMC 1,0 % + 0,0010 (abs.) 10 nF 至 1 µF；1 kHz 0,00 至 1,6 CMC 0,50 % + 0,0005 (abs.) MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"92dac8980ca1c982412d8ada","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"21","test_object":"Indukcyjność / mostki RLC, wzorce indukcyjności","test_object_en":"Inductance / RLC bridges, inductance standards","test_object_zh":"电感 / RLC 电桥、电感标准","test_object_cs":"Indukčnost / RLC mosty, etalony indukčnosti","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 kHz do 1 MHz","range":"100 µH","cmc":"0,50 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"5 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,050 %"},{"name":"1 kHz do 100 kHz","range":"100 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"200 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"500 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"1 H","cmc":"0,050 %"},{"name":"1 kHz","range":"2 H","cmc":"0,10 %"},{"name":"1 kHz","range":"5 H","cmc":"0,10 %"},{"name":"1 kHz","range":"10 H","cmc":"0,10 %"}],"parameters_en":[{"name":"10 kHz to 1 MHz","range":"100 µH","cmc":"0,50 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"5 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,050 %"},{"name":"1 kHz to 100 kHz","range":"100 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"200 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"500 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"1 H","cmc":"0,050 %"},{"name":"1 kHz","range":"2 H","cmc":"0,10 %"},{"name":"1 kHz","range":"5 H","cmc":"0,10 %"},{"name":"1 kHz","range":"10 H","cmc":"0,10 %"}],"parameters_zh":[{"name":"10 kHz 至 1 MHz","range":"100 µH","cmc":"0,50 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"5 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,050 %"},{"name":"1 kHz 至 100 kHz","range":"100 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"200 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"500 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"1 H","cmc":"0,050 %"},{"name":"1 kHz","range":"2 H","cmc":"0,10 %"},{"name":"1 kHz","range":"5 H","cmc":"0,10 %"},{"name":"1 kHz","range":"10 H","cmc":"0,10 %"}],"parameters_cs":[{"name":"10 kHz až 1 MHz","range":"100 µH","cmc":"0,50 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"5 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"20 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"50 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,050 %"},{"name":"1 kHz až 100 kHz","range":"100 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"200 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"500 mH","cmc":"0,050 %"},{"name":"1 kHz","range":"1 H","cmc":"0,050 %"},{"name":"1 kHz","range":"2 H","cmc":"0,10 %"},{"name":"1 kHz","range":"5 H","cmc":"0,10 %"},{"name":"1 kHz","range":"10 H","cmc":"0,10 %"}],"technique":"Wzorce indukcyjności: pomiar bezpośredni lub porównanie","technique_en":"Inductance standards: direct measurement or comparison","technique_zh":"电感标准：直接测量或比较","technique_cs":"Etalony indukčnosti: přímé měření nebo porovnání","techniques":["Wzorce indukcyjności: pomiar bezpośredni lub porównanie"],"techniques_en":["Inductance standards: direct measurement or comparison"],"techniques_zh":["电感标准：直接测量或比较"],"techniques_cs":["Etalony indukčnosti: přímé měření nebo porovnání"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 kHz do 1 MHz 100 µH CMC 0,50 %\n1 kHz 2 mH CMC 0,10 %\n1 kHz 5 mH CMC 0,10 %\n1 kHz 10 mH CMC 0,10 %\n1 kHz 20 mH CMC 0,10 %\n1 kHz 50 mH CMC 0,050 %\n1 kHz 100 mH CMC 0,050 %\n1 kHz do 100 kHz 100 mH CMC 0,20 %\n1 kHz 200 mH CMC 0,050 %\n1 kHz 500 mH CMC 0,050 %\n1 kHz 1 H CMC 0,050 %\n1 kHz 2 H CMC 0,10 %\n1 kHz 5 H CMC 0,10 %\n1 kHz 10 H CMC 0,10 %\nWzorce indukcyjności: pomiar bezpośredni lub porównanie","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indukcyjność / mostki RLC, wzorce indukcyjności Wzorcowanie – wielkości elektryczne Wzorce indukcyjności: pomiar bezpośredni lub porównanie 10 kHz do 1 MHz 100 µH CMC 0,50 % 1 kHz 2 mH CMC 0,10 % 1 kHz 5 mH CMC 0,10 % 1 kHz 10 mH CMC 0,10 % 1 kHz 20 mH CMC 0,10 % 1 kHz 50 mH CMC 0,050 % 1 kHz 100 mH CMC 0,050 % 1 kHz do 100 kHz 100 mH CMC 0,20 % 1 kHz 200 mH CMC 0,050 % 1 kHz 500 mH CMC 0,050 % 1 kHz 1 H CMC 0,050 % 1 kHz 2 H CMC 0,10 % 1 kHz 5 H CMC 0,10 % 1 kHz 10 H CMC 0,10 % Indukčnost / RLC mosty, etalony indukčnosti Kalibrace – elektrické veličiny Etalony indukčnosti: přímé měření nebo porovnání 10 kHz až 1 MHz 100 µH CMC 0,50 % 1 kHz 2 mH CMC 0,10 % 1 kHz 5 mH CMC 0,10 % 1 kHz 10 mH CMC 0,10 % 1 kHz 20 mH CMC 0,10 % 1 kHz 50 mH CMC 0,050 % 1 kHz 100 mH CMC 0,050 % 1 kHz až 100 kHz 100 mH CMC 0,20 % 1 kHz 200 mH CMC 0,050 % 1 kHz 500 mH CMC 0,050 % 1 kHz 1 H CMC 0,050 % 1 kHz 2 H CMC 0,10 % 1 kHz 5 H CMC 0,10 % 1 kHz 10 H CMC 0,10 % MK15 Indukcyjnosc / mostki RLC, wzorce indukcyjnosci Wzorcowanie – wielkosci elektryczne Wzorce indukcyjnosci: pomiar bezposredni lub porownanie 10 kHz do 1 MHz 100 µH CMC 0,50 % 1 kHz 2 mH CMC 0,10 % 1 kHz 5 mH CMC 0,10 % 1 kHz 10 mH CMC 0,10 % 1 kHz 20 mH CMC 0,10 % 1 kHz 50 mH CMC 0,050 % 1 kHz 100 mH CMC 0,050 % 1 kHz do 100 kHz 100 mH CMC 0,20 % 1 kHz 200 mH CMC 0,050 % 1 kHz 500 mH CMC 0,050 % 1 kHz 1 H CMC 0,050 % 1 kHz 2 H CMC 0,10 % 1 kHz 5 H CMC 0,10 % 1 kHz 10 H CMC 0,10 % Indukcnost / RLC mosty, etalony indukcnosti Kalibrace – elektricke veliciny Etalony indukcnosti: prime mereni nebo porovnani 10 kHz az 1 MHz 100 µH CMC 0,50 % 1 kHz 2 mH CMC 0,10 % 1 kHz 5 mH CMC 0,10 % 1 kHz 10 mH CMC 0,10 % 1 kHz 20 mH CMC 0,10 % 1 kHz 50 mH CMC 0,050 % 1 kHz 100 mH CMC 0,050 % 1 kHz az 100 kHz 100 mH CMC 0,20 % 1 kHz 200 mH CMC 0,050 % 1 kHz 500 mH CMC 0,050 % 1 kHz 1 H CMC 0,050 % 1 kHz 2 H CMC 0,10 % 1 kHz 5 H CMC 0,10 % 1 kHz 10 H CMC 0,10 % MK15","search_en":"Inductance / RLC bridges, inductance standards Calibration – electrical quantities Inductance standards: direct measurement or comparison 10 kHz to 1 MHz 100 µH CMC 0,50 % 1 kHz 2 mH CMC 0,10 % 1 kHz 5 mH CMC 0,10 % 1 kHz 10 mH CMC 0,10 % 1 kHz 20 mH CMC 0,10 % 1 kHz 50 mH CMC 0,050 % 1 kHz 100 mH CMC 0,050 % 1 kHz to 100 kHz 100 mH CMC 0,20 % 1 kHz 200 mH CMC 0,050 % 1 kHz 500 mH CMC 0,050 % 1 kHz 1 H CMC 0,050 % 1 kHz 2 H CMC 0,10 % 1 kHz 5 H CMC 0,10 % 1 kHz 10 H CMC 0,10 % MK15","search_zh":"电感 / RLC 电桥、电感标准 校准 – 电学量 电感标准：直接测量或比较 10 kHz 至 1 MHz 100 µH CMC 0,50 % 1 kHz 2 mH CMC 0,10 % 1 kHz 5 mH CMC 0,10 % 1 kHz 10 mH CMC 0,10 % 1 kHz 20 mH CMC 0,10 % 1 kHz 50 mH CMC 0,050 % 1 kHz 100 mH CMC 0,050 % 1 kHz 至 100 kHz 100 mH CMC 0,20 % 1 kHz 200 mH CMC 0,050 % 1 kHz 500 mH CMC 0,050 % 1 kHz 1 H CMC 0,050 % 1 kHz 2 H CMC 0,10 % 1 kHz 5 H CMC 0,10 % 1 kHz 10 H CMC 0,10 % MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff5b2a15f9b6e02cf78c4ec4","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"21","test_object":"Indukcyjność / wzorce indukcyjności, dekady indukcyjne","test_object_en":"Inductance / Inductance standards, inductance decades","test_object_zh":"电感 / 电感标准、电感箱","test_object_cs":"Indukčnost / Etalony indukčnosti, indukční dekády","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"od 1 mH do 10 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"od 10 mH do 500 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"od 500 mH do 5 H","cmc":"0,20 %"},{"name":"1 kHz","range":"od 5 H do 10 H","cmc":"0,50 %"}],"parameters_en":[{"name":"1 kHz","range":"1 mH to 10 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"10 mH to 500 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"500 mH to 5 H","cmc":"0,20 %"},{"name":"1 kHz","range":"5 H to 10 H","cmc":"0,50 %"}],"parameters_zh":[{"name":"1 kHz","range":"1 mH 至 10 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"10 mH 至 500 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"500 mH 至 5 H","cmc":"0,20 %"},{"name":"1 kHz","range":"5 H 至 10 H","cmc":"0,50 %"}],"parameters_cs":[{"name":"1 kHz","range":"1 mH až 10 mH","cmc":"0,20 %"},{"name":"1 kHz","range":"10 mH až 500 mH","cmc":"0,10 %"},{"name":"1 kHz","range":"500 mH až 5 H","cmc":"0,20 %"},{"name":"1 kHz","range":"5 H až 10 H","cmc":"0,50 %"}],"technique":"Pomiar bezpośredni wzorcowym mostkiem RLC","technique_en":"Direct measurement by a standard RLC bridge","technique_zh":"用标准 RLC 电桥直接测量","technique_cs":"Přímé měření etalonovým RLC mostem","techniques":["Pomiar bezpośredni wzorcowym mostkiem RLC"],"techniques_en":["Direct measurement by a standard RLC bridge"],"techniques_zh":["用标准 RLC 电桥直接测量"],"techniques_cs":["Přímé měření etalonovým RLC mostem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz od 1 mH do 10 mH CMC 0,20 %\n1 kHz od 10 mH do 500 mH CMC 0,10 %\n1 kHz od 500 mH do 5 H CMC 0,20 %\n1 kHz od 5 H do 10 H CMC 0,50 %\nPomiar bezpośredni wzorcowym mostkiem RLC","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indukcyjność / wzorce indukcyjności, dekady indukcyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowym mostkiem RLC 1 kHz od 1 mH do 10 mH CMC 0,20 % 1 kHz od 10 mH do 500 mH CMC 0,10 % 1 kHz od 500 mH do 5 H CMC 0,20 % 1 kHz od 5 H do 10 H CMC 0,50 % Indukčnost / Etalony indukčnosti, indukční dekády Kalibrace – elektrické veličiny Přímé měření etalonovým RLC mostem 1 kHz 1 mH až 10 mH CMC 0,20 % 1 kHz 10 mH až 500 mH CMC 0,10 % 1 kHz 500 mH až 5 H CMC 0,20 % 1 kHz 5 H až 10 H CMC 0,50 % MK15 Indukcyjnosc / wzorce indukcyjnosci, dekady indukcyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowym mostkiem RLC 1 kHz od 1 mH do 10 mH CMC 0,20 % 1 kHz od 10 mH do 500 mH CMC 0,10 % 1 kHz od 500 mH do 5 H CMC 0,20 % 1 kHz od 5 H do 10 H CMC 0,50 % Indukcnost / Etalony indukcnosti, indukcni dekady Kalibrace – elektricke veliciny Prime mereni etalonovym RLC mostem 1 kHz 1 mH az 10 mH CMC 0,20 % 1 kHz 10 mH az 500 mH CMC 0,10 % 1 kHz 500 mH az 5 H CMC 0,20 % 1 kHz 5 H az 10 H CMC 0,50 % MK15","search_en":"Inductance / Inductance standards, inductance decades Calibration – electrical quantities Direct measurement by a standard RLC bridge 1 kHz 1 mH to 10 mH CMC 0,20 % 1 kHz 10 mH to 500 mH CMC 0,10 % 1 kHz 500 mH to 5 H CMC 0,20 % 1 kHz 5 H to 10 H CMC 0,50 % MK15","search_zh":"电感 / 电感标准、电感箱 校准 – 电学量 用标准 RLC 电桥直接测量 1 kHz 1 mH 至 10 mH CMC 0,20 % 1 kHz 10 mH 至 500 mH CMC 0,10 % 1 kHz 500 mH 至 5 H CMC 0,20 % 1 kHz 5 H 至 10 H CMC 0,50 % MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8da35aa5b5f19dadf9169a57","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"22","test_object":"Moduł impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne","test_object_en":"Impedance magnitude / Artificial networks, coupling networks, impedance elements","test_object_zh":"阻抗模 / 人工电源网络、耦合网络、阻抗元件","test_object_cs":"Modul impedance / Umělé sítě, vazební členy, impedanční prvky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz do 100 kHz","range":"od 0,1 Ω do 1 Ω","cmc":"0,50 % + 3 mΩ"},{"name":"1 kHz do 100 kHz","range":"od 1 Ω do 10 Ω","cmc":"0,30 %"},{"name":"100 kHz do 1 MHz","range":"od 1 Ω do 10 Ω","cmc":"0,50 %"},{"name":"1 kHz","range":"od 10 Ω do 1 kΩ","cmc":"0,10 %"},{"name":"1 kHz do 1 MHz","range":"od 10 Ω do 1 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"od 1 kΩ do 10 kΩ","cmc":"0,10 %"},{"name":"1 kHz do 1 MHz","range":"od 1 kΩ do 10 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"od 10 kΩ do 100 kΩ","cmc":"0,10 %"},{"name":"1 kHz do 100 kHz","range":"od 10 kΩ do 100 kΩ","cmc":"0,20 %"}],"parameters_en":[{"name":"1 kHz to 100 kHz","range":"0,1 Ω to 1 Ω","cmc":"0,50 % + 3 mΩ"},{"name":"1 kHz to 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,30 %"},{"name":"100 kHz to 1 MHz","range":"1 Ω to 10 Ω","cmc":"0,50 %"},{"name":"1 kHz","range":"10 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"1 kHz to 1 MHz","range":"10 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,10 %"},{"name":"1 kHz to 1 MHz","range":"1 kΩ to 10 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,10 %"},{"name":"1 kHz to 100 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,20 %"}],"parameters_zh":[{"name":"1 kHz 至 100 kHz","range":"0,1 Ω 至 1 Ω","cmc":"0,50 % + 3 mΩ"},{"name":"1 kHz 至 100 kHz","range":"1 Ω 至 10 Ω","cmc":"0,30 %"},{"name":"100 kHz 至 1 MHz","range":"1 Ω 至 10 Ω","cmc":"0,50 %"},{"name":"1 kHz","range":"10 Ω 至 1 kΩ","cmc":"0,10 %"},{"name":"1 kHz 至 1 MHz","range":"10 Ω 至 1 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"1 kΩ 至 10 kΩ","cmc":"0,10 %"},{"name":"1 kHz 至 1 MHz","range":"1 kΩ 至 10 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"10 kΩ 至 100 kΩ","cmc":"0,10 %"},{"name":"1 kHz 至 100 kHz","range":"10 kΩ 至 100 kΩ","cmc":"0,20 %"}],"parameters_cs":[{"name":"1 kHz až 100 kHz","range":"0,1 Ω až 1 Ω","cmc":"0,50 % + 3 mΩ"},{"name":"1 kHz až 100 kHz","range":"1 Ω až 10 Ω","cmc":"0,30 %"},{"name":"100 kHz až 1 MHz","range":"1 Ω až 10 Ω","cmc":"0,50 %"},{"name":"1 kHz","range":"10 Ω až 1 kΩ","cmc":"0,10 %"},{"name":"1 kHz až 1 MHz","range":"10 Ω až 1 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"1 kΩ až 10 kΩ","cmc":"0,10 %"},{"name":"1 kHz až 1 MHz","range":"1 kΩ až 10 kΩ","cmc":"0,20 %"},{"name":"1 kHz","range":"10 kΩ až 100 kΩ","cmc":"0,10 %"},{"name":"1 kHz až 100 kHz","range":"10 kΩ až 100 kΩ","cmc":"0,20 %"}],"technique":"Pomiar bezpośredni wzorcowym mostkiem RLC","technique_en":"Direct measurement by a standard RLC bridge","technique_zh":"用标准 RLC 电桥直接测量","technique_cs":"Přímé měření etalonovým RLC mostem","techniques":["Pomiar bezpośredni wzorcowym mostkiem RLC"],"techniques_en":["Direct measurement by a standard RLC bridge"],"techniques_zh":["用标准 RLC 电桥直接测量"],"techniques_cs":["Přímé měření etalonovým RLC mostem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz do 100 kHz od 0,1 Ω do 1 Ω CMC 0,50 % + 3 mΩ\n1 kHz do 100 kHz od 1 Ω do 10 Ω CMC 0,30 %\n100 kHz do 1 MHz od 1 Ω do 10 Ω CMC 0,50 %\n1 kHz od 10 Ω do 1 kΩ CMC 0,10 %\n1 kHz do 1 MHz od 10 Ω do 1 kΩ CMC 0,20 %\n1 kHz od 1 kΩ do 10 kΩ CMC 0,10 %\n1 kHz do 1 MHz od 1 kΩ do 10 kΩ CMC 0,20 %\n1 kHz od 10 kΩ do 100 kΩ CMC 0,10 %\n1 kHz do 100 kHz od 10 kΩ do 100 kΩ CMC 0,20 %\nPomiar bezpośredni wzorcowym mostkiem RLC","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowym mostkiem RLC 1 kHz do 100 kHz od 0,1 Ω do 1 Ω CMC 0,50 % + 3 mΩ 1 kHz do 100 kHz od 1 Ω do 10 Ω CMC 0,30 % 100 kHz do 1 MHz od 1 Ω do 10 Ω CMC 0,50 % 1 kHz od 10 Ω do 1 kΩ CMC 0,10 % 1 kHz do 1 MHz od 10 Ω do 1 kΩ CMC 0,20 % 1 kHz od 1 kΩ do 10 kΩ CMC 0,10 % 1 kHz do 1 MHz od 1 kΩ do 10 kΩ CMC 0,20 % 1 kHz od 10 kΩ do 100 kΩ CMC 0,10 % 1 kHz do 100 kHz od 10 kΩ do 100 kΩ CMC 0,20 % Modul impedance / Umělé sítě, vazební členy, impedanční prvky Kalibrace – elektrické veličiny Přímé měření etalonovým RLC mostem 1 kHz až 100 kHz 0,1 Ω až 1 Ω CMC 0,50 % + 3 mΩ 1 kHz až 100 kHz 1 Ω až 10 Ω CMC 0,30 % 100 kHz až 1 MHz 1 Ω až 10 Ω CMC 0,50 % 1 kHz 10 Ω až 1 kΩ CMC 0,10 % 1 kHz až 1 MHz 10 Ω až 1 kΩ CMC 0,20 % 1 kHz 1 kΩ až 10 kΩ CMC 0,10 % 1 kHz až 1 MHz 1 kΩ až 10 kΩ CMC 0,20 % 1 kHz 10 kΩ až 100 kΩ CMC 0,10 % 1 kHz až 100 kHz 10 kΩ až 100 kΩ CMC 0,20 % MK15 Modul impedancji / sztuczne sieci, czlony sprzegajace, elementy impedancyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowym mostkiem RLC 1 kHz do 100 kHz od 0,1 Ω do 1 Ω CMC 0,50 % + 3 mΩ 1 kHz do 100 kHz od 1 Ω do 10 Ω CMC 0,30 % 100 kHz do 1 MHz od 1 Ω do 10 Ω CMC 0,50 % 1 kHz od 10 Ω do 1 kΩ CMC 0,10 % 1 kHz do 1 MHz od 10 Ω do 1 kΩ CMC 0,20 % 1 kHz od 1 kΩ do 10 kΩ CMC 0,10 % 1 kHz do 1 MHz od 1 kΩ do 10 kΩ CMC 0,20 % 1 kHz od 10 kΩ do 100 kΩ CMC 0,10 % 1 kHz do 100 kHz od 10 kΩ do 100 kΩ CMC 0,20 % Modul impedance / Umele site, vazebni cleny, impedancni prvky Kalibrace – elektricke veliciny Prime mereni etalonovym RLC mostem 1 kHz az 100 kHz 0,1 Ω az 1 Ω CMC 0,50 % + 3 mΩ 1 kHz az 100 kHz 1 Ω az 10 Ω CMC 0,30 % 100 kHz az 1 MHz 1 Ω az 10 Ω CMC 0,50 % 1 kHz 10 Ω az 1 kΩ CMC 0,10 % 1 kHz az 1 MHz 10 Ω az 1 kΩ CMC 0,20 % 1 kHz 1 kΩ az 10 kΩ CMC 0,10 % 1 kHz az 1 MHz 1 kΩ az 10 kΩ CMC 0,20 % 1 kHz 10 kΩ az 100 kΩ CMC 0,10 % 1 kHz az 100 kHz 10 kΩ az 100 kΩ CMC 0,20 % MK15","search_en":"Impedance magnitude / Artificial networks, coupling networks, impedance elements Calibration – electrical quantities Direct measurement by a standard RLC bridge 1 kHz to 100 kHz 0,1 Ω to 1 Ω CMC 0,50 % + 3 mΩ 1 kHz to 100 kHz 1 Ω to 10 Ω CMC 0,30 % 100 kHz to 1 MHz 1 Ω to 10 Ω CMC 0,50 % 1 kHz 10 Ω to 1 kΩ CMC 0,10 % 1 kHz to 1 MHz 10 Ω to 1 kΩ CMC 0,20 % 1 kHz 1 kΩ to 10 kΩ CMC 0,10 % 1 kHz to 1 MHz 1 kΩ to 10 kΩ CMC 0,20 % 1 kHz 10 kΩ to 100 kΩ CMC 0,10 % 1 kHz to 100 kHz 10 kΩ to 100 kΩ CMC 0,20 % MK15","search_zh":"阻抗模 / 人工电源网络、耦合网络、阻抗元件 校准 – 电学量 用标准 RLC 电桥直接测量 1 kHz 至 100 kHz 0,1 Ω 至 1 Ω CMC 0,50 % + 3 mΩ 1 kHz 至 100 kHz 1 Ω 至 10 Ω CMC 0,30 % 100 kHz 至 1 MHz 1 Ω 至 10 Ω CMC 0,50 % 1 kHz 10 Ω 至 1 kΩ CMC 0,10 % 1 kHz 至 1 MHz 10 Ω 至 1 kΩ CMC 0,20 % 1 kHz 1 kΩ 至 10 kΩ CMC 0,10 % 1 kHz 至 1 MHz 1 kΩ 至 10 kΩ CMC 0,20 % 1 kHz 10 kΩ 至 100 kΩ CMC 0,10 % 1 kHz 至 100 kHz 10 kΩ 至 100 kΩ CMC 0,20 % MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0520283174603a2394adbba9","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"22","test_object":"Moduł impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne","test_object_en":"Impedance magnitude / Artificial networks, coupling networks, impedance elements","test_object_zh":"阻抗模 / 人工电源网络、耦合网络、阻抗元件","test_object_cs":"Modul impedance / Umělé sítě, vazební členy, impedanční prvky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 MHz do 400 MHz","range":"od 20 Ω do 40 Ω","cmc":"3,0 %"},{"name":"1 MHz do 2 GHz","range":"od 40 Ω do 60 Ω","cmc":"2,0 %"},{"name":"1 MHz do 400 MHz","range":"od 60 Ω do 125 Ω","cmc":"3,0 %"},{"name":"1 MHz do 400 MHz","range":"od 125 Ω do 200 Ω","cmc":"6,0 %"}],"parameters_en":[{"name":"1 MHz to 400 MHz","range":"20 Ω to 40 Ω","cmc":"3,0 %"},{"name":"1 MHz to 2 GHz","range":"40 Ω to 60 Ω","cmc":"2,0 %"},{"name":"1 MHz to 400 MHz","range":"60 Ω to 125 Ω","cmc":"3,0 %"},{"name":"1 MHz to 400 MHz","range":"125 Ω to 200 Ω","cmc":"6,0 %"}],"parameters_zh":[{"name":"1 MHz 至 400 MHz","range":"20 Ω 至 40 Ω","cmc":"3,0 %"},{"name":"1 MHz 至 2 GHz","range":"40 Ω 至 60 Ω","cmc":"2,0 %"},{"name":"1 MHz 至 400 MHz","range":"60 Ω 至 125 Ω","cmc":"3,0 %"},{"name":"1 MHz 至 400 MHz","range":"125 Ω 至 200 Ω","cmc":"6,0 %"}],"parameters_cs":[{"name":"1 MHz až 400 MHz","range":"20 Ω až 40 Ω","cmc":"3,0 %"},{"name":"1 MHz až 2 GHz","range":"40 Ω až 60 Ω","cmc":"2,0 %"},{"name":"1 MHz až 400 MHz","range":"60 Ω až 125 Ω","cmc":"3,0 %"},{"name":"1 MHz až 400 MHz","range":"125 Ω až 200 Ω","cmc":"6,0 %"}],"technique":"Pomiar wzorcowym wektorowym analizatorem obwodów","technique_en":"Measurement by a standard vector network analyser","technique_zh":"用标准矢量网络分析仪测量","technique_cs":"Měření etalonovým vektorovým analyzátorem obvodů","techniques":["Pomiar wzorcowym wektorowym analizatorem obwodów"],"techniques_en":["Measurement by a standard vector network analyser"],"techniques_zh":["用标准矢量网络分析仪测量"],"techniques_cs":["Měření etalonovým vektorovým analyzátorem obvodů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 MHz do 400 MHz od 20 Ω do 40 Ω CMC 3,0 %\n1 MHz do 2 GHz od 40 Ω do 60 Ω CMC 2,0 %\n1 MHz do 400 MHz od 60 Ω do 125 Ω CMC 3,0 %\n1 MHz do 400 MHz od 125 Ω do 200 Ω CMC 6,0 %\nPomiar wzorcowym wektorowym analizatorem obwodów","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne Wzorcowanie – wielkości elektryczne Pomiar wzorcowym wektorowym analizatorem obwodów 1 MHz do 400 MHz od 20 Ω do 40 Ω CMC 3,0 % 1 MHz do 2 GHz od 40 Ω do 60 Ω CMC 2,0 % 1 MHz do 400 MHz od 60 Ω do 125 Ω CMC 3,0 % 1 MHz do 400 MHz od 125 Ω do 200 Ω CMC 6,0 % Modul impedance / Umělé sítě, vazební členy, impedanční prvky Kalibrace – elektrické veličiny Měření etalonovým vektorovým analyzátorem obvodů 1 MHz až 400 MHz 20 Ω až 40 Ω CMC 3,0 % 1 MHz až 2 GHz 40 Ω až 60 Ω CMC 2,0 % 1 MHz až 400 MHz 60 Ω až 125 Ω CMC 3,0 % 1 MHz až 400 MHz 125 Ω až 200 Ω CMC 6,0 % MK16 Modul impedancji / sztuczne sieci, czlony sprzegajace, elementy impedancyjne Wzorcowanie – wielkosci elektryczne Pomiar wzorcowym wektorowym analizatorem obwodow 1 MHz do 400 MHz od 20 Ω do 40 Ω CMC 3,0 % 1 MHz do 2 GHz od 40 Ω do 60 Ω CMC 2,0 % 1 MHz do 400 MHz od 60 Ω do 125 Ω CMC 3,0 % 1 MHz do 400 MHz od 125 Ω do 200 Ω CMC 6,0 % Modul impedance / Umele site, vazebni cleny, impedancni prvky Kalibrace – elektricke veliciny Mereni etalonovym vektorovym analyzatorem obvodu 1 MHz az 400 MHz 20 Ω az 40 Ω CMC 3,0 % 1 MHz az 2 GHz 40 Ω az 60 Ω CMC 2,0 % 1 MHz az 400 MHz 60 Ω az 125 Ω CMC 3,0 % 1 MHz az 400 MHz 125 Ω az 200 Ω CMC 6,0 % MK16","search_en":"Impedance magnitude / Artificial networks, coupling networks, impedance elements Calibration – electrical quantities Measurement by a standard vector network analyser 1 MHz to 400 MHz 20 Ω to 40 Ω CMC 3,0 % 1 MHz to 2 GHz 40 Ω to 60 Ω CMC 2,0 % 1 MHz to 400 MHz 60 Ω to 125 Ω CMC 3,0 % 1 MHz to 400 MHz 125 Ω to 200 Ω CMC 6,0 % MK16","search_zh":"阻抗模 / 人工电源网络、耦合网络、阻抗元件 校准 – 电学量 用标准矢量网络分析仪测量 1 MHz 至 400 MHz 20 Ω 至 40 Ω CMC 3,0 % 1 MHz 至 2 GHz 40 Ω 至 60 Ω CMC 2,0 % 1 MHz 至 400 MHz 60 Ω 至 125 Ω CMC 3,0 % 1 MHz 至 400 MHz 125 Ω 至 200 Ω CMC 6,0 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b76dba380e1487505aa1011","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"23","test_object":"Kąt fazowy impedancji / mostki RLC","test_object_en":"Impedance phase angle / RLC bridges","test_object_zh":"阻抗相角 / RLC 电桥","test_object_cs":"Fázový úhel impedance / RLC mosty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,1 Ω; 1 kHz do 100 kHz","range":"od -0,3° do 0,3°","cmc":"(0,05 + 0,8·f)°"},{"name":"1 Ω; 1 kHz","range":"od -0,3° do 0,3°","cmc":"0,005°"},{"name":"1 Ω; 1 kHz do 1 MHz","range":"od -0,3° do 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"10 Ω; 1 kHz","range":"od -0,3° do 0,3°","cmc":"0,005°"},{"name":"10 Ω; 1 kHz do 1 MHz","range":"od -0,3° do 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"100 Ω; 1 kHz","range":"od -0,3° do 0,3°","cmc":"0,005°"},{"name":"100 Ω; 1 kHz do 1 MHz","range":"od -0,3° do 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"1 kΩ; 1 kHz","range":"od -0,3° do 0,3°","cmc":"0,005°"},{"name":"1 kΩ; 1 kHz do 1 MHz","range":"od -0,3° do 0,3°","cmc":"(0,005 + 0,5·f)°"}],"parameters_en":[{"name":"0,1 Ω; 1 kHz to 100 kHz","range":"-0,3° to 0,3°","cmc":"(0,05 + 0,8·f)°"},{"name":"1 Ω; 1 kHz","range":"-0,3° to 0,3°","cmc":"0,005°"},{"name":"1 Ω; 1 kHz to 1 MHz","range":"-0,3° to 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"10 Ω; 1 kHz","range":"-0,3° to 0,3°","cmc":"0,005°"},{"name":"10 Ω; 1 kHz to 1 MHz","range":"-0,3° to 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"100 Ω; 1 kHz","range":"-0,3° to 0,3°","cmc":"0,005°"},{"name":"100 Ω; 1 kHz to 1 MHz","range":"-0,3° to 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"1 kΩ; 1 kHz","range":"-0,3° to 0,3°","cmc":"0,005°"},{"name":"1 kΩ; 1 kHz to 1 MHz","range":"-0,3° to 0,3°","cmc":"(0,005 + 0,5·f)°"}],"parameters_zh":[{"name":"0,1 Ω；1 kHz 至 100 kHz","range":"-0,3° 至 0,3°","cmc":"(0,05 + 0,8·f)°"},{"name":"1 Ω; 1 kHz","range":"-0,3° 至 0,3°","cmc":"0,005°"},{"name":"1 Ω；1 kHz 至 1 MHz","range":"-0,3° 至 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"10 Ω; 1 kHz","range":"-0,3° 至 0,3°","cmc":"0,005°"},{"name":"10 Ω；1 kHz 至 1 MHz","range":"-0,3° 至 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"100 Ω; 1 kHz","range":"-0,3° 至 0,3°","cmc":"0,005°"},{"name":"100 Ω；1 kHz 至 1 MHz","range":"-0,3° 至 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"1 kΩ; 1 kHz","range":"-0,3° 至 0,3°","cmc":"0,005°"},{"name":"1 kΩ；1 kHz 至 1 MHz","range":"-0,3° 至 0,3°","cmc":"(0,005 + 0,5·f)°"}],"parameters_cs":[{"name":"0,1 Ω; 1 kHz až 100 kHz","range":"-0,3° až 0,3°","cmc":"(0,05 + 0,8·f)°"},{"name":"1 Ω; 1 kHz","range":"-0,3° až 0,3°","cmc":"0,005°"},{"name":"1 Ω; 1 kHz až 1 MHz","range":"-0,3° až 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"10 Ω; 1 kHz","range":"-0,3° až 0,3°","cmc":"0,005°"},{"name":"10 Ω; 1 kHz až 1 MHz","range":"-0,3° až 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"100 Ω; 1 kHz","range":"-0,3° až 0,3°","cmc":"0,005°"},{"name":"100 Ω; 1 kHz až 1 MHz","range":"-0,3° až 0,3°","cmc":"(0,005 + 0,2·f)°"},{"name":"1 kΩ; 1 kHz","range":"-0,3° až 0,3°","cmc":"0,005°"},{"name":"1 kΩ; 1 kHz až 1 MHz","range":"-0,3° až 0,3°","cmc":"(0,005 + 0,5·f)°"}],"technique":"Pomiar bezpośredni wzorców rezystancji przy prądzie przemiennym (częstotliwość f w MHz)","technique_en":"Direct measurement of AC resistance standards (frequency f in MHz)","technique_zh":"直接测量交流电阻标准（频率 f 以 MHz 计）","technique_cs":"Přímé měření etalonů střídavého odporu (frekvence f je v MHz)","techniques":["Pomiar bezpośredni wzorców rezystancji przy prądzie przemiennym (częstotliwość f w MHz)"],"techniques_en":["Direct measurement of AC resistance standards (frequency f in MHz)"],"techniques_zh":["直接测量交流电阻标准（频率 f 以 MHz 计）"],"techniques_cs":["Přímé měření etalonů střídavého odporu (frekvence f je v MHz)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 Ω; 1 kHz do 100 kHz od -0,3° do 0,3° CMC (0,05 + 0,8·f)°\n1 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005°\n1 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)°\n10 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005°\n10 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)°\n100 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005°\n100 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)°\n1 kΩ; 1 kHz od -0,3° do 0,3° CMC 0,005°\n1 kΩ; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,5·f)°\nPomiar bezpośredni wzorców rezystancji przy prądzie przemiennym (częstotliwość f w MHz)","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt fazowy impedancji / mostki RLC Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorców rezystancji przy prądzie przemiennym (częstotliwość f w MHz) 0,1 Ω; 1 kHz do 100 kHz od -0,3° do 0,3° CMC (0,05 + 0,8·f)° 1 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005° 1 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)° 10 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005° 10 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)° 100 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005° 100 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)° 1 kΩ; 1 kHz od -0,3° do 0,3° CMC 0,005° 1 kΩ; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,5·f)° Fázový úhel impedance / RLC mosty Kalibrace – elektrické veličiny Přímé měření etalonů střídavého odporu (frekvence f je v MHz) 0,1 Ω; 1 kHz až 100 kHz -0,3° až 0,3° CMC (0,05 + 0,8·f)° 1 Ω; 1 kHz -0,3° až 0,3° CMC 0,005° 1 Ω; 1 kHz až 1 MHz -0,3° až 0,3° CMC (0,005 + 0,2·f)° 10 Ω; 1 kHz -0,3° až 0,3° CMC 0,005° 10 Ω; 1 kHz až 1 MHz -0,3° až 0,3° CMC (0,005 + 0,2·f)° 100 Ω; 1 kHz -0,3° až 0,3° CMC 0,005° 100 Ω; 1 kHz až 1 MHz -0,3° až 0,3° CMC (0,005 + 0,2·f)° 1 kΩ; 1 kHz -0,3° až 0,3° CMC 0,005° 1 kΩ; 1 kHz až 1 MHz -0,3° až 0,3° CMC (0,005 + 0,5·f)° MK15 Kat fazowy impedancji / mostki RLC Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcow rezystancji przy pradzie przemiennym (czestotliwosc f w MHz) 0,1 Ω; 1 kHz do 100 kHz od -0,3° do 0,3° CMC (0,05 + 0,8·f)° 1 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005° 1 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)° 10 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005° 10 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)° 100 Ω; 1 kHz od -0,3° do 0,3° CMC 0,005° 100 Ω; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,2·f)° 1 kΩ; 1 kHz od -0,3° do 0,3° CMC 0,005° 1 kΩ; 1 kHz do 1 MHz od -0,3° do 0,3° CMC (0,005 + 0,5·f)° Fazovy uhel impedance / RLC mosty Kalibrace – elektricke veliciny Prime mereni etalonu stridaveho odporu (frekvence f je v MHz) 0,1 Ω; 1 kHz az 100 kHz -0,3° az 0,3° CMC (0,05 + 0,8·f)° 1 Ω; 1 kHz -0,3° az 0,3° CMC 0,005° 1 Ω; 1 kHz az 1 MHz -0,3° az 0,3° CMC (0,005 + 0,2·f)° 10 Ω; 1 kHz -0,3° az 0,3° CMC 0,005° 10 Ω; 1 kHz az 1 MHz -0,3° az 0,3° CMC (0,005 + 0,2·f)° 100 Ω; 1 kHz -0,3° az 0,3° CMC 0,005° 100 Ω; 1 kHz az 1 MHz -0,3° az 0,3° CMC (0,005 + 0,2·f)° 1 kΩ; 1 kHz -0,3° az 0,3° CMC 0,005° 1 kΩ; 1 kHz az 1 MHz -0,3° az 0,3° CMC (0,005 + 0,5·f)° MK15","search_en":"Impedance phase angle / RLC bridges Calibration – electrical quantities Direct measurement of AC resistance standards (frequency f in MHz) 0,1 Ω; 1 kHz to 100 kHz -0,3° to 0,3° CMC (0,05 + 0,8·f)° 1 Ω; 1 kHz -0,3° to 0,3° CMC 0,005° 1 Ω; 1 kHz to 1 MHz -0,3° to 0,3° CMC (0,005 + 0,2·f)° 10 Ω; 1 kHz -0,3° to 0,3° CMC 0,005° 10 Ω; 1 kHz to 1 MHz -0,3° to 0,3° CMC (0,005 + 0,2·f)° 100 Ω; 1 kHz -0,3° to 0,3° CMC 0,005° 100 Ω; 1 kHz to 1 MHz -0,3° to 0,3° CMC (0,005 + 0,2·f)° 1 kΩ; 1 kHz -0,3° to 0,3° CMC 0,005° 1 kΩ; 1 kHz to 1 MHz -0,3° to 0,3° CMC (0,005 + 0,5·f)° MK15","search_zh":"阻抗相角 / RLC 电桥 校准 – 电学量 直接测量交流电阻标准（频率 f 以 MHz 计） 0,1 Ω；1 kHz 至 100 kHz -0,3° 至 0,3° CMC (0,05 + 0,8·f)° 1 Ω; 1 kHz -0,3° 至 0,3° CMC 0,005° 1 Ω；1 kHz 至 1 MHz -0,3° 至 0,3° CMC (0,005 + 0,2·f)° 10 Ω; 1 kHz -0,3° 至 0,3° CMC 0,005° 10 Ω；1 kHz 至 1 MHz -0,3° 至 0,3° CMC (0,005 + 0,2·f)° 100 Ω; 1 kHz -0,3° 至 0,3° CMC 0,005° 100 Ω；1 kHz 至 1 MHz -0,3° 至 0,3° CMC (0,005 + 0,2·f)° 1 kΩ; 1 kHz -0,3° 至 0,3° CMC 0,005° 1 kΩ；1 kHz 至 1 MHz -0,3° 至 0,3° CMC (0,005 + 0,5·f)° MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"625252245dc6dd426ccca1d1","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"23","test_object":"Kąt fazowy impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne","test_object_en":"Impedance phase angle / Artificial networks, coupling networks, impedance elements","test_object_zh":"阻抗相角 / 人工电源网络、耦合网络、阻抗元件","test_object_cs":"Fázový úhel impedance / Umělé sítě, vazební členy, impedanční prvky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,1 Ω do 1 Ω; 1 kHz do 100 kHz","range":"od -90° do 90°","cmc":"(0,3 + 0,8·f)°"},{"name":"1 Ω do 10 Ω; 1 kHz do 100 kHz","range":"od -90° do 90°","cmc":"0,3°"},{"name":"1 Ω do 10 Ω; 100 kHz do 1 MHz","range":"od -90° do 90°","cmc":"(0,3 + 0,2·f)°"},{"name":"10 Ω do 1 kΩ; 1 kHz","range":"od -90° do 90°","cmc":"0,1°"},{"name":"10 Ω do 1 kΩ; 1 kHz do 1 MHz","range":"od -90° do 90°","cmc":"(0,1 + 0,5·f)°"}],"parameters_en":[{"name":"0,1 Ω to 1 Ω; 1 kHz to 100 kHz","range":"-90° to 90°","cmc":"(0,3 + 0,8·f)°"},{"name":"1 Ω to 10 Ω; 1 kHz to 100 kHz","range":"-90° to 90°","cmc":"0,3°"},{"name":"1 Ω to 10 Ω; 100 kHz to 1 MHz","range":"-90° to 90°","cmc":"(0,3 + 0,2·f)°"},{"name":"10 Ω to 1 kΩ; 1 kHz","range":"-90° to 90°","cmc":"0,1°"},{"name":"10 Ω to 1 kΩ; 1 kHz to 1 MHz","range":"-90° to 90°","cmc":"(0,1 + 0,5·f)°"}],"parameters_zh":[{"name":"0,1 Ω 至 1 Ω；1 kHz 至 100 kHz","range":"-90° 至 90°","cmc":"(0,3 + 0,8·f)°"},{"name":"1 Ω 至 10 Ω；1 kHz 至 100 kHz","range":"-90° 至 90°","cmc":"0,3°"},{"name":"1 Ω 至 10 Ω；100 kHz 至 1 MHz","range":"-90° 至 90°","cmc":"(0,3 + 0,2·f)°"},{"name":"10 Ω 至 1 kΩ；1 kHz","range":"-90° 至 90°","cmc":"0,1°"},{"name":"10 Ω 至 1 kΩ；1 kHz 至 1 MHz","range":"-90° 至 90°","cmc":"(0,1 + 0,5·f)°"}],"parameters_cs":[{"name":"0,1 Ω až 1 Ω; 1 kHz až 100 kHz","range":"-90° až 90°","cmc":"(0,3 + 0,8·f)°"},{"name":"1 Ω až 10 Ω; 1 kHz až 100 kHz","range":"-90° až 90°","cmc":"0,3°"},{"name":"1 Ω až 10 Ω; 100 kHz až 1 MHz","range":"-90° až 90°","cmc":"(0,3 + 0,2·f)°"},{"name":"10 Ω až 1 kΩ; 1 kHz","range":"-90° až 90°","cmc":"0,1°"},{"name":"10 Ω až 1 kΩ; 1 kHz až 1 MHz","range":"-90° až 90°","cmc":"(0,1 + 0,5·f)°"}],"technique":"Pomiar bezpośredni wzorcowym mostkiem RLC (częstotliwość f w MHz)","technique_en":"Direct measurement by a standard RLC bridge (frequency f in MHz)","technique_zh":"用标准 RLC 电桥直接测量（频率 f 以 MHz 计）","technique_cs":"Přímé měření etalonovým RLC mostem (frekvence f je v MHz)","techniques":["Pomiar bezpośredni wzorcowym mostkiem RLC (częstotliwość f w MHz)"],"techniques_en":["Direct measurement by a standard RLC bridge (frequency f in MHz)"],"techniques_zh":["用标准 RLC 电桥直接测量（频率 f 以 MHz 计）"],"techniques_cs":["Přímé měření etalonovým RLC mostem (frekvence f je v MHz)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 Ω do 1 Ω; 1 kHz do 100 kHz od -90° do 90° CMC (0,3 + 0,8·f)°\n1 Ω do 10 Ω; 1 kHz do 100 kHz od -90° do 90° CMC 0,3°\n1 Ω do 10 Ω; 100 kHz do 1 MHz od -90° do 90° CMC (0,3 + 0,2·f)°\n10 Ω do 1 kΩ; 1 kHz od -90° do 90° CMC 0,1°\n10 Ω do 1 kΩ; 1 kHz do 1 MHz od -90° do 90° CMC (0,1 + 0,5·f)°\nPomiar bezpośredni wzorcowym mostkiem RLC (częstotliwość f w MHz)","reference":"MK15","norm_bases":["MK15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt fazowy impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowym mostkiem RLC (częstotliwość f w MHz) 0,1 Ω do 1 Ω; 1 kHz do 100 kHz od -90° do 90° CMC (0,3 + 0,8·f)° 1 Ω do 10 Ω; 1 kHz do 100 kHz od -90° do 90° CMC 0,3° 1 Ω do 10 Ω; 100 kHz do 1 MHz od -90° do 90° CMC (0,3 + 0,2·f)° 10 Ω do 1 kΩ; 1 kHz od -90° do 90° CMC 0,1° 10 Ω do 1 kΩ; 1 kHz do 1 MHz od -90° do 90° CMC (0,1 + 0,5·f)° Fázový úhel impedance / Umělé sítě, vazební členy, impedanční prvky Kalibrace – elektrické veličiny Přímé měření etalonovým RLC mostem (frekvence f je v MHz) 0,1 Ω až 1 Ω; 1 kHz až 100 kHz -90° až 90° CMC (0,3 + 0,8·f)° 1 Ω až 10 Ω; 1 kHz až 100 kHz -90° až 90° CMC 0,3° 1 Ω až 10 Ω; 100 kHz až 1 MHz -90° až 90° CMC (0,3 + 0,2·f)° 10 Ω až 1 kΩ; 1 kHz -90° až 90° CMC 0,1° 10 Ω až 1 kΩ; 1 kHz až 1 MHz -90° až 90° CMC (0,1 + 0,5·f)° MK15 Kat fazowy impedancji / sztuczne sieci, czlony sprzegajace, elementy impedancyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowym mostkiem RLC (czestotliwosc f w MHz) 0,1 Ω do 1 Ω; 1 kHz do 100 kHz od -90° do 90° CMC (0,3 + 0,8·f)° 1 Ω do 10 Ω; 1 kHz do 100 kHz od -90° do 90° CMC 0,3° 1 Ω do 10 Ω; 100 kHz do 1 MHz od -90° do 90° CMC (0,3 + 0,2·f)° 10 Ω do 1 kΩ; 1 kHz od -90° do 90° CMC 0,1° 10 Ω do 1 kΩ; 1 kHz do 1 MHz od -90° do 90° CMC (0,1 + 0,5·f)° Fazovy uhel impedance / Umele site, vazebni cleny, impedancni prvky Kalibrace – elektricke veliciny Prime mereni etalonovym RLC mostem (frekvence f je v MHz) 0,1 Ω az 1 Ω; 1 kHz az 100 kHz -90° az 90° CMC (0,3 + 0,8·f)° 1 Ω az 10 Ω; 1 kHz az 100 kHz -90° az 90° CMC 0,3° 1 Ω az 10 Ω; 100 kHz az 1 MHz -90° az 90° CMC (0,3 + 0,2·f)° 10 Ω az 1 kΩ; 1 kHz -90° az 90° CMC 0,1° 10 Ω az 1 kΩ; 1 kHz az 1 MHz -90° az 90° CMC (0,1 + 0,5·f)° MK15","search_en":"Impedance phase angle / Artificial networks, coupling networks, impedance elements Calibration – electrical quantities Direct measurement by a standard RLC bridge (frequency f in MHz) 0,1 Ω to 1 Ω; 1 kHz to 100 kHz -90° to 90° CMC (0,3 + 0,8·f)° 1 Ω to 10 Ω; 1 kHz to 100 kHz -90° to 90° CMC 0,3° 1 Ω to 10 Ω; 100 kHz to 1 MHz -90° to 90° CMC (0,3 + 0,2·f)° 10 Ω to 1 kΩ; 1 kHz -90° to 90° CMC 0,1° 10 Ω to 1 kΩ; 1 kHz to 1 MHz -90° to 90° CMC (0,1 + 0,5·f)° MK15","search_zh":"阻抗相角 / 人工电源网络、耦合网络、阻抗元件 校准 – 电学量 用标准 RLC 电桥直接测量（频率 f 以 MHz 计） 0,1 Ω 至 1 Ω；1 kHz 至 100 kHz -90° 至 90° CMC (0,3 + 0,8·f)° 1 Ω 至 10 Ω；1 kHz 至 100 kHz -90° 至 90° CMC 0,3° 1 Ω 至 10 Ω；100 kHz 至 1 MHz -90° 至 90° CMC (0,3 + 0,2·f)° 10 Ω 至 1 kΩ；1 kHz -90° 至 90° CMC 0,1° 10 Ω 至 1 kΩ；1 kHz 至 1 MHz -90° 至 90° CMC (0,1 + 0,5·f)° MK15","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aa754d326b4c3468c93e9d50","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"23","test_object":"Kąt fazowy impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne","test_object_en":"Impedance phase angle / Artificial networks, coupling networks, impedance elements","test_object_zh":"阻抗相角 / 人工电源网络、耦合网络、阻抗元件","test_object_cs":"Fázový úhel impedance / Umělé sítě, vazební členy, impedanční prvky","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Ω do 40 Ω; 1 MHz do 400 MHz","range":"od -90° do 90°","cmc":"2,5°"},{"name":"40 Ω do 60 Ω; 1 MHz do 2 GHz","range":"od -90° do 90°","cmc":"1,5°"},{"name":"60 Ω do 125 Ω; 1 MHz do 400 MHz","range":"od -90° do 90°","cmc":"2,5°"},{"name":"125 Ω do 200 Ω; 1 MHz do 400 MHz","range":"od -90° do 90°","cmc":"5,0°"}],"parameters_en":[{"name":"20 Ω to 40 Ω; 1 MHz to 400 MHz","range":"-90° to 90°","cmc":"2,5°"},{"name":"40 Ω to 60 Ω; 1 MHz to 2 GHz","range":"-90° to 90°","cmc":"1,5°"},{"name":"60 Ω to 125 Ω; 1 MHz to 400 MHz","range":"-90° to 90°","cmc":"2,5°"},{"name":"125 Ω to 200 Ω; 1 MHz to 400 MHz","range":"-90° to 90°","cmc":"5,0°"}],"parameters_zh":[{"name":"20 Ω 至 40 Ω；1 MHz 至 400 MHz","range":"-90° 至 90°","cmc":"2,5°"},{"name":"40 Ω 至 60 Ω；1 MHz 至 2 GHz","range":"-90° 至 90°","cmc":"1,5°"},{"name":"60 Ω 至 125 Ω；1 MHz 至 400 MHz","range":"-90° 至 90°","cmc":"2,5°"},{"name":"125 Ω 至 200 Ω；1 MHz 至 400 MHz","range":"-90° 至 90°","cmc":"5,0°"}],"parameters_cs":[{"name":"20 Ω až 40 Ω; 1 MHz až 400 MHz","range":"-90° až 90°","cmc":"2,5°"},{"name":"40 Ω až 60 Ω; 1 MHz až 2 GHz","range":"-90° až 90°","cmc":"1,5°"},{"name":"60 Ω až 125 Ω; 1 MHz až 400 MHz","range":"-90° až 90°","cmc":"2,5°"},{"name":"125 Ω až 200 Ω; 1 MHz až 400 MHz","range":"-90° až 90°","cmc":"5,0°"}],"technique":"Pomiar wektorowym analizatorem obwodów","technique_en":"Measurement by a vector network analyser","technique_zh":"用矢量网络分析仪测量","technique_cs":"Měření vektorovým analyzátorem obvodů","techniques":["Pomiar wektorowym analizatorem obwodów"],"techniques_en":["Measurement by a vector network analyser"],"techniques_zh":["用矢量网络分析仪测量"],"techniques_cs":["Měření vektorovým analyzátorem obvodů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Ω do 40 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 2,5°\n40 Ω do 60 Ω; 1 MHz do 2 GHz od -90° do 90° CMC 1,5°\n60 Ω do 125 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 2,5°\n125 Ω do 200 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 5,0°\nPomiar wektorowym analizatorem obwodów","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kąt fazowy impedancji / sztuczne sieci, człony sprzęgające, elementy impedancyjne Wzorcowanie – wielkości elektryczne Pomiar wektorowym analizatorem obwodów 20 Ω do 40 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 2,5° 40 Ω do 60 Ω; 1 MHz do 2 GHz od -90° do 90° CMC 1,5° 60 Ω do 125 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 2,5° 125 Ω do 200 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 5,0° Fázový úhel impedance / Umělé sítě, vazební členy, impedanční prvky Kalibrace – elektrické veličiny Měření vektorovým analyzátorem obvodů 20 Ω až 40 Ω; 1 MHz až 400 MHz -90° až 90° CMC 2,5° 40 Ω až 60 Ω; 1 MHz až 2 GHz -90° až 90° CMC 1,5° 60 Ω až 125 Ω; 1 MHz až 400 MHz -90° až 90° CMC 2,5° 125 Ω až 200 Ω; 1 MHz až 400 MHz -90° až 90° CMC 5,0° MK16 Kat fazowy impedancji / sztuczne sieci, czlony sprzegajace, elementy impedancyjne Wzorcowanie – wielkosci elektryczne Pomiar wektorowym analizatorem obwodow 20 Ω do 40 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 2,5° 40 Ω do 60 Ω; 1 MHz do 2 GHz od -90° do 90° CMC 1,5° 60 Ω do 125 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 2,5° 125 Ω do 200 Ω; 1 MHz do 400 MHz od -90° do 90° CMC 5,0° Fazovy uhel impedance / Umele site, vazebni cleny, impedancni prvky Kalibrace – elektricke veliciny Mereni vektorovym analyzatorem obvodu 20 Ω az 40 Ω; 1 MHz az 400 MHz -90° az 90° CMC 2,5° 40 Ω az 60 Ω; 1 MHz az 2 GHz -90° az 90° CMC 1,5° 60 Ω az 125 Ω; 1 MHz az 400 MHz -90° az 90° CMC 2,5° 125 Ω az 200 Ω; 1 MHz az 400 MHz -90° az 90° CMC 5,0° MK16","search_en":"Impedance phase angle / Artificial networks, coupling networks, impedance elements Calibration – electrical quantities Measurement by a vector network analyser 20 Ω to 40 Ω; 1 MHz to 400 MHz -90° to 90° CMC 2,5° 40 Ω to 60 Ω; 1 MHz to 2 GHz -90° to 90° CMC 1,5° 60 Ω to 125 Ω; 1 MHz to 400 MHz -90° to 90° CMC 2,5° 125 Ω to 200 Ω; 1 MHz to 400 MHz -90° to 90° CMC 5,0° MK16","search_zh":"阻抗相角 / 人工电源网络、耦合网络、阻抗元件 校准 – 电学量 用矢量网络分析仪测量 20 Ω 至 40 Ω；1 MHz 至 400 MHz -90° 至 90° CMC 2,5° 40 Ω 至 60 Ω；1 MHz 至 2 GHz -90° 至 90° CMC 1,5° 60 Ω 至 125 Ω；1 MHz 至 400 MHz -90° 至 90° CMC 2,5° 125 Ω 至 200 Ω；1 MHz 至 400 MHz -90° 至 90° CMC 5,0° MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b8afffb100a2ce6ae80a8b4a","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"24","test_object":"Moc prądu przemiennego / watomierze, kalibratory mocy w zakresie częstotliwości od 45 Hz do 65 Hz, współczynnik mocy od 0 do 1","test_object_en":"AC power / Wattmeters, power calibrators in the frequency range 45 Hz to 65 Hz, power factor 0 to 1","test_object_zh":"交流功率 / 功率表、功率校准器，频率范围 45 Hz 至 65 Hz，功率因数 0 至 1","test_object_cs":"Střídavý výkon / Wattmetry, kalibrátory výkonu v rozsahu kmitočtů 45 Hz až 65 Hz, účiník 0 až 1","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"30 V do 1020 V; 3,3 mA do 0,15 A","range":"od 0 W do 153 W","cmc":"1,2 mW/VA"},{"name":"3,3 V do 30 V; 3,3 mA do 20,5 A","range":"od 0 W do 615 W","cmc":"1,2 mW/VA"},{"name":"720 V do 1020 V; 3,3 mA do 20,5 A","range":"od 0 W do 20,9 kW","cmc":"1,2 mW/VA"}],"parameters_en":[{"name":"30 V to 1020 V; 3,3 mA to 0,15 A","range":"0 W to 153 W","cmc":"1,2 mW/VA"},{"name":"3,3 V to 30 V; 3,3 mA to 20,5 A","range":"0 W to 615 W","cmc":"1,2 mW/VA"},{"name":"720 V to 1020 V; 3,3 mA to 20,5 A","range":"0 W to 20,9 kW","cmc":"1,2 mW/VA"}],"parameters_zh":[{"name":"30 V 至 1020 V；3,3 mA 至 0,15 A","range":"0 W 至 153 W","cmc":"1,2 mW/VA"},{"name":"3,3 V 至 30 V；3,3 mA 至 20,5 A","range":"0 W 至 615 W","cmc":"1,2 mW/VA"},{"name":"720 V 至 1020 V；3,3 mA 至 20,5 A","range":"0 W 至 20,9 kW","cmc":"1,2 mW/VA"}],"parameters_cs":[{"name":"30 V až 1020 V; 3,3 mA až 0,15 A","range":"0 W až 153 W","cmc":"1,2 mW/VA"},{"name":"3,3 V až 30 V; 3,3 mA až 20,5 A","range":"0 W až 615 W","cmc":"1,2 mW/VA"},{"name":"720 V až 1020 V; 3,3 mA až 20,5 A","range":"0 W až 20,9 kW","cmc":"1,2 mW/VA"}],"technique":"Bezpośrednie generowanie wzorcowym kalibratorem mocy","technique_en":"Direct generation by a standard power calibrator","technique_zh":"用标准功率校准器直接产生","technique_cs":"Přímé generování etalonovým kalibrátorem výkonu","techniques":["Bezpośrednie generowanie wzorcowym kalibratorem mocy"],"techniques_en":["Direct generation by a standard power calibrator"],"techniques_zh":["用标准功率校准器直接产生"],"techniques_cs":["Přímé generování etalonovým kalibrátorem výkonu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n30 V do 1020 V; 3,3 mA do 0,15 A od 0 W do 153 W CMC 1,2 mW/VA\n3,3 V do 30 V; 3,3 mA do 20,5 A od 0 W do 615 W CMC 1,2 mW/VA\n720 V do 1020 V; 3,3 mA do 20,5 A od 0 W do 20,9 kW CMC 1,2 mW/VA\nBezpośrednie generowanie wzorcowym kalibratorem mocy","reference":"MK3, MK7","norm_bases":["MK3","MK7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu przemiennego / watomierze, kalibratory mocy w zakresie częstotliwości od 45 Hz do 65 Hz, współczynnik mocy od 0 do 1 Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie wzorcowym kalibratorem mocy 30 V do 1020 V; 3,3 mA do 0,15 A od 0 W do 153 W CMC 1,2 mW/VA 3,3 V do 30 V; 3,3 mA do 20,5 A od 0 W do 615 W CMC 1,2 mW/VA 720 V do 1020 V; 3,3 mA do 20,5 A od 0 W do 20,9 kW CMC 1,2 mW/VA Střídavý výkon / Wattmetry, kalibrátory výkonu v rozsahu kmitočtů 45 Hz až 65 Hz, účiník 0 až 1 Kalibrace – elektrické veličiny Přímé generování etalonovým kalibrátorem výkonu 30 V až 1020 V; 3,3 mA až 0,15 A 0 W až 153 W CMC 1,2 mW/VA 3,3 V až 30 V; 3,3 mA až 20,5 A 0 W až 615 W CMC 1,2 mW/VA 720 V až 1020 V; 3,3 mA až 20,5 A 0 W až 20,9 kW CMC 1,2 mW/VA MK3, MK7 Moc pradu przemiennego / watomierze, kalibratory mocy w zakresie czestotliwosci od 45 Hz do 65 Hz, wspolczynnik mocy od 0 do 1 Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie wzorcowym kalibratorem mocy 30 V do 1020 V; 3,3 mA do 0,15 A od 0 W do 153 W CMC 1,2 mW/VA 3,3 V do 30 V; 3,3 mA do 20,5 A od 0 W do 615 W CMC 1,2 mW/VA 720 V do 1020 V; 3,3 mA do 20,5 A od 0 W do 20,9 kW CMC 1,2 mW/VA Stridavy vykon / Wattmetry, kalibratory vykonu v rozsahu kmitoctu 45 Hz az 65 Hz, ucinik 0 az 1 Kalibrace – elektricke veliciny Prime generovani etalonovym kalibratorem vykonu 30 V az 1020 V; 3,3 mA az 0,15 A 0 W az 153 W CMC 1,2 mW/VA 3,3 V az 30 V; 3,3 mA az 20,5 A 0 W az 615 W CMC 1,2 mW/VA 720 V az 1020 V; 3,3 mA az 20,5 A 0 W az 20,9 kW CMC 1,2 mW/VA MK3, MK7","search_en":"AC power / Wattmeters, power calibrators in the frequency range 45 Hz to 65 Hz, power factor 0 to 1 Calibration – electrical quantities Direct generation by a standard power calibrator 30 V to 1020 V; 3,3 mA to 0,15 A 0 W to 153 W CMC 1,2 mW/VA 3,3 V to 30 V; 3,3 mA to 20,5 A 0 W to 615 W CMC 1,2 mW/VA 720 V to 1020 V; 3,3 mA to 20,5 A 0 W to 20,9 kW CMC 1,2 mW/VA MK3, MK7","search_zh":"交流功率 / 功率表、功率校准器，频率范围 45 Hz 至 65 Hz，功率因数 0 至 1 校准 – 电学量 用标准功率校准器直接产生 30 V 至 1020 V；3,3 mA 至 0,15 A 0 W 至 153 W CMC 1,2 mW/VA 3,3 V 至 30 V；3,3 mA 至 20,5 A 0 W 至 615 W CMC 1,2 mW/VA 720 V 至 1020 V；3,3 mA 至 20,5 A 0 W 至 20,9 kW CMC 1,2 mW/VA MK3, MK7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f369253b5c9f24e949a522d","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"24","test_object":"Moc prądu przemiennego / watomierze, kalibratory mocy w zakresie częstotliwości od 45 Hz do 65 Hz, współczynnik mocy od 0 do 1","test_object_en":"AC power / Wattmeters, power calibrators in the frequency range 45 Hz to 65 Hz, power factor 0 to 1","test_object_zh":"交流功率 / 功率表、功率校准器，频率范围 45 Hz 至 65 Hz，功率因数 0 至 1","test_object_cs":"Střídavý výkon / Wattmetry, kalibrátory výkonu v rozsahu kmitočtů 45 Hz až 65 Hz, účiník 0 až 1","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"30 V do 60 V; 0,15 A do 0,30 A","range":"od 0 W do 1,23 kW","cmc":"7,4 mW"},{"name":"30 V do 60 V; 0,30 A do 0,60 A","range":"od 0 W do 1,23 kW","cmc":"15 mW"},{"name":"30 V do 60 V; 0,60 A do 1,3 A","range":"od 0 W do 1,23 kW","cmc":"30 mW"},{"name":"30 V do 60 V; 1,3 A do 2,6 A","range":"od 0 W do 1,23 kW","cmc":"61 mW"},{"name":"30 V do 60 V; 2,6 A do 5,2 A","range":"od 0 W do 1,23 kW","cmc":"0,12 W"},{"name":"30 V do 60 V; 5,2 A do 10 A","range":"od 0 W do 1,23 kW","cmc":"0,24 W"},{"name":"30 V do 60 V; 10 A do 20,5 A","range":"od 0 W do 1,23 kW","cmc":"0,49 W"},{"name":"60 V do 130 V; 0,15 A do 0,30 A","range":"od 0 W do 2,67 kW","cmc":"15 mW"},{"name":"60 V do 130 V; 0,30 A do 0,60 A","range":"od 0 W do 2,67 kW","cmc":"30 mW"},{"name":"60 V do 130 V; 0,60 A do 1,3 A","range":"od 0 W do 2,67 kW","cmc":"63 mW"},{"name":"60 V do 130 V; 1,3 A do 2,6 A","range":"od 0 W do 2,67 kW","cmc":"0,13 W"},{"name":"60 V do 130 V; 2,6 A do 5,2 A","range":"od 0 W do 2,67 kW","cmc":"0,25 W"},{"name":"60 V do 130 V; 5,2 A do 10 A","range":"od 0 W do 2,67 kW","cmc":"0,50 W"},{"name":"60 V do 130 V; 10 A do 20,5 A","range":"od 0 W do 2,67 kW","cmc":"1,0 W"},{"name":"130 V do 270 V; 0,15 A do 0,30 A","range":"od 0 W do 5,54 kW","cmc":"31 mW"},{"name":"130 V do 270 V; 0,30 A do 0,60 A","range":"od 0 W do 5,54 kW","cmc":"62 mW"},{"name":"130 V do 270 V; 0,60 A do 1,3 A","range":"od 0 W do 5,54 kW","cmc":"0,13 W"},{"name":"130 V do 270 V; 1,3 A do 2,6 A","range":"od 0 W do 5,54 kW","cmc":"0,26 W"},{"name":"130 V do 270 V; 2,6 A do 5,2 A","range":"od 0 W do 5,54 kW","cmc":"0,51 W"},{"name":"130 V do 270 V; 5,2 A do 10 A","range":"od 0 W do 5,54 kW","cmc":"1,0 W"},{"name":"130 V do 270 V; 10 A do 20,5 A","range":"od 0 W do 5,54 kW","cmc":"2,1 W"},{"name":"270 V do 560 V; 0,15 A do 0,30 A","range":"od 0 W do 11,48 kW","cmc":"63 mW"},{"name":"270 V do 560 V; 0,30 A do 0,60 A","range":"od 0 W do 11,48 kW","cmc":"0,13 W"},{"name":"270 V do 560 V; 0,60 A do 1,3 A","range":"od 0 W do 11,48 kW","cmc":"0,26 W"},{"name":"270 V do 560 V; 1,3 A do 2,6 A","range":"od 0 W do 11,48 kW","cmc":"0,52 W"},{"name":"270 V do 560 V; 2,6 A do 5,2 A","range":"od 0 W do 11,48 kW","cmc":"1,0 W"},{"name":"270 V do 560 V; 5,2 A do 10 A","range":"od 0 W do 11,48 kW","cmc":"2,0 W"},{"name":"270 V do 560 V; 10 A do 20,5 A","range":"od 0 W do 11,48 kW","cmc":"4,2 W"},{"name":"560 V do 720 V; 0,15 A do 0,30 A","range":"od 0 W do 14,74 kW","cmc":"0,11 W"},{"name":"560 V do 720 V; 0,30 A do 0,60 A","range":"od 0 W do 14,74 kW","cmc":"0,21 W"},{"name":"560 V do 720 V; 0,60 A do 1,3 A","range":"od 0 W do 14,74 kW","cmc":"0,44 W"},{"name":"560 V do 720 V; 1,3 A do 2,6 A","range":"od 0 W do 14,74 kW","cmc":"0,88 W"},{"name":"560 V do 720 V; 2,6 A do 5,2 A","range":"od 0 W do 14,74 kW","cmc":"1,8 W"},{"name":"560 V do 720 V; 5,2 A do 10 A","range":"od 0 W do 14,74 kW","cmc":"3,5 W"},{"name":"560 V do 720 V; 10 A do 20,5 A","range":"od 0 W do 14,74 kW","cmc":"7,1 W"}],"parameters_en":[{"name":"30 V to 60 V; 0,15 A to 0,30 A","range":"0 W to 1,23 kW","cmc":"7,4 mW"},{"name":"30 V to 60 V; 0,30 A to 0,60 A","range":"0 W to 1,23 kW","cmc":"15 mW"},{"name":"30 V to 60 V; 0,60 A to 1,3 A","range":"0 W to 1,23 kW","cmc":"30 mW"},{"name":"30 V to 60 V; 1,3 A to 2,6 A","range":"0 W to 1,23 kW","cmc":"61 mW"},{"name":"30 V to 60 V; 2,6 A to 5,2 A","range":"0 W to 1,23 kW","cmc":"0,12 W"},{"name":"30 V to 60 V; 5,2 A to 10 A","range":"0 W to 1,23 kW","cmc":"0,24 W"},{"name":"30 V to 60 V; 10 A to 20,5 A","range":"0 W to 1,23 kW","cmc":"0,49 W"},{"name":"60 V to 130 V; 0,15 A to 0,30 A","range":"0 W to 2,67 kW","cmc":"15 mW"},{"name":"60 V to 130 V; 0,30 A to 0,60 A","range":"0 W to 2,67 kW","cmc":"30 mW"},{"name":"60 V to 130 V; 0,60 A to 1,3 A","range":"0 W to 2,67 kW","cmc":"63 mW"},{"name":"60 V to 130 V; 1,3 A to 2,6 A","range":"0 W to 2,67 kW","cmc":"0,13 W"},{"name":"60 V to 130 V; 2,6 A to 5,2 A","range":"0 W to 2,67 kW","cmc":"0,25 W"},{"name":"60 V to 130 V; 5,2 A to 10 A","range":"0 W to 2,67 kW","cmc":"0,50 W"},{"name":"60 V to 130 V; 10 A to 20,5 A","range":"0 W to 2,67 kW","cmc":"1,0 W"},{"name":"130 V to 270 V; 0,15 A to 0,30 A","range":"0 W to 5,54 kW","cmc":"31 mW"},{"name":"130 V to 270 V; 0,30 A to 0,60 A","range":"0 W to 5,54 kW","cmc":"62 mW"},{"name":"130 V to 270 V; 0,60 A to 1,3 A","range":"0 W to 5,54 kW","cmc":"0,13 W"},{"name":"130 V to 270 V; 1,3 A to 2,6 A","range":"0 W to 5,54 kW","cmc":"0,26 W"},{"name":"130 V to 270 V; 2,6 A to 5,2 A","range":"0 W to 5,54 kW","cmc":"0,51 W"},{"name":"130 V to 270 V; 5,2 A to 10 A","range":"0 W to 5,54 kW","cmc":"1,0 W"},{"name":"130 V to 270 V; 10 A to 20,5 A","range":"0 W to 5,54 kW","cmc":"2,1 W"},{"name":"270 V to 560 V; 0,15 A to 0,30 A","range":"0 W to 11,48 kW","cmc":"63 mW"},{"name":"270 V to 560 V; 0,30 A to 0,60 A","range":"0 W to 11,48 kW","cmc":"0,13 W"},{"name":"270 V to 560 V; 0,60 A to 1,3 A","range":"0 W to 11,48 kW","cmc":"0,26 W"},{"name":"270 V to 560 V; 1,3 A to 2,6 A","range":"0 W to 11,48 kW","cmc":"0,52 W"},{"name":"270 V to 560 V; 2,6 A to 5,2 A","range":"0 W to 11,48 kW","cmc":"1,0 W"},{"name":"270 V to 560 V; 5,2 A to 10 A","range":"0 W to 11,48 kW","cmc":"2,0 W"},{"name":"270 V to 560 V; 10 A to 20,5 A","range":"0 W to 11,48 kW","cmc":"4,2 W"},{"name":"560 V to 720 V; 0,15 A to 0,30 A","range":"0 W to 14,74 kW","cmc":"0,11 W"},{"name":"560 V to 720 V; 0,30 A to 0,60 A","range":"0 W to 14,74 kW","cmc":"0,21 W"},{"name":"560 V to 720 V; 0,60 A to 1,3 A","range":"0 W to 14,74 kW","cmc":"0,44 W"},{"name":"560 V to 720 V; 1,3 A to 2,6 A","range":"0 W to 14,74 kW","cmc":"0,88 W"},{"name":"560 V to 720 V; 2,6 A to 5,2 A","range":"0 W to 14,74 kW","cmc":"1,8 W"},{"name":"560 V to 720 V; 5,2 A to 10 A","range":"0 W to 14,74 kW","cmc":"3,5 W"},{"name":"560 V to 720 V; 10 A to 20,5 A","range":"0 W to 14,74 kW","cmc":"7,1 W"}],"parameters_zh":[{"name":"30 V 至 60 V；0,15 A 至 0,30 A","range":"0 W 至 1,23 kW","cmc":"7,4 mW"},{"name":"30 V 至 60 V；0,30 A 至 0,60 A","range":"0 W 至 1,23 kW","cmc":"15 mW"},{"name":"30 V 至 60 V；0,60 A 至 1,3 A","range":"0 W 至 1,23 kW","cmc":"30 mW"},{"name":"30 V 至 60 V；1,3 A 至 2,6 A","range":"0 W 至 1,23 kW","cmc":"61 mW"},{"name":"30 V 至 60 V；2,6 A 至 5,2 A","range":"0 W 至 1,23 kW","cmc":"0,12 W"},{"name":"30 V 至 60 V；5,2 A 至 10 A","range":"0 W 至 1,23 kW","cmc":"0,24 W"},{"name":"30 V 至 60 V；10 A 至 20,5 A","range":"0 W 至 1,23 kW","cmc":"0,49 W"},{"name":"60 V 至 130 V；0,15 A 至 0,30 A","range":"0 W 至 2,67 kW","cmc":"15 mW"},{"name":"60 V 至 130 V；0,30 A 至 0,60 A","range":"0 W 至 2,67 kW","cmc":"30 mW"},{"name":"60 V 至 130 V；0,60 A 至 1,3 A","range":"0 W 至 2,67 kW","cmc":"63 mW"},{"name":"60 V 至 130 V；1,3 A 至 2,6 A","range":"0 W 至 2,67 kW","cmc":"0,13 W"},{"name":"60 V 至 130 V；2,6 A 至 5,2 A","range":"0 W 至 2,67 kW","cmc":"0,25 W"},{"name":"60 V 至 130 V；5,2 A 至 10 A","range":"0 W 至 2,67 kW","cmc":"0,50 W"},{"name":"60 V 至 130 V；10 A 至 20,5 A","range":"0 W 至 2,67 kW","cmc":"1,0 W"},{"name":"130 V 至 270 V；0,15 A 至 0,30 A","range":"0 W 至 5,54 kW","cmc":"31 mW"},{"name":"130 V 至 270 V；0,30 A 至 0,60 A","range":"0 W 至 5,54 kW","cmc":"62 mW"},{"name":"130 V 至 270 V；0,60 A 至 1,3 A","range":"0 W 至 5,54 kW","cmc":"0,13 W"},{"name":"130 V 至 270 V；1,3 A 至 2,6 A","range":"0 W 至 5,54 kW","cmc":"0,26 W"},{"name":"130 V 至 270 V；2,6 A 至 5,2 A","range":"0 W 至 5,54 kW","cmc":"0,51 W"},{"name":"130 V 至 270 V；5,2 A 至 10 A","range":"0 W 至 5,54 kW","cmc":"1,0 W"},{"name":"130 V 至 270 V；10 A 至 20,5 A","range":"0 W 至 5,54 kW","cmc":"2,1 W"},{"name":"270 V 至 560 V；0,15 A 至 0,30 A","range":"0 W 至 11,48 kW","cmc":"63 mW"},{"name":"270 V 至 560 V；0,30 A 至 0,60 A","range":"0 W 至 11,48 kW","cmc":"0,13 W"},{"name":"270 V 至 560 V；0,60 A 至 1,3 A","range":"0 W 至 11,48 kW","cmc":"0,26 W"},{"name":"270 V 至 560 V；1,3 A 至 2,6 A","range":"0 W 至 11,48 kW","cmc":"0,52 W"},{"name":"270 V 至 560 V；2,6 A 至 5,2 A","range":"0 W 至 11,48 kW","cmc":"1,0 W"},{"name":"270 V 至 560 V；5,2 A 至 10 A","range":"0 W 至 11,48 kW","cmc":"2,0 W"},{"name":"270 V 至 560 V；10 A 至 20,5 A","range":"0 W 至 11,48 kW","cmc":"4,2 W"},{"name":"560 V 至 720 V；0,15 A 至 0,30 A","range":"0 W 至 14,74 kW","cmc":"0,11 W"},{"name":"560 V 至 720 V；0,30 A 至 0,60 A","range":"0 W 至 14,74 kW","cmc":"0,21 W"},{"name":"560 V 至 720 V；0,60 A 至 1,3 A","range":"0 W 至 14,74 kW","cmc":"0,44 W"},{"name":"560 V 至 720 V；1,3 A 至 2,6 A","range":"0 W 至 14,74 kW","cmc":"0,88 W"},{"name":"560 V 至 720 V；2,6 A 至 5,2 A","range":"0 W 至 14,74 kW","cmc":"1,8 W"},{"name":"560 V 至 720 V；5,2 A 至 10 A","range":"0 W 至 14,74 kW","cmc":"3,5 W"},{"name":"560 V 至 720 V；10 A 至 20,5 A","range":"0 W 至 14,74 kW","cmc":"7,1 W"}],"parameters_cs":[{"name":"30 V až 60 V; 0,15 A až 0,30 A","range":"0 W až 1,23 kW","cmc":"7,4 mW"},{"name":"30 V až 60 V; 0,30 A až 0,60 A","range":"0 W až 1,23 kW","cmc":"15 mW"},{"name":"30 V až 60 V; 0,60 A až 1,3 A","range":"0 W až 1,23 kW","cmc":"30 mW"},{"name":"30 V až 60 V; 1,3 A až 2,6 A","range":"0 W až 1,23 kW","cmc":"61 mW"},{"name":"30 V až 60 V; 2,6 A až 5,2 A","range":"0 W až 1,23 kW","cmc":"0,12 W"},{"name":"30 V až 60 V; 5,2 A až 10 A","range":"0 W až 1,23 kW","cmc":"0,24 W"},{"name":"30 V až 60 V; 10 A až 20,5 A","range":"0 W až 1,23 kW","cmc":"0,49 W"},{"name":"60 V až 130 V; 0,15 A až 0,30 A","range":"0 W až 2,67 kW","cmc":"15 mW"},{"name":"60 V až 130 V; 0,30 A až 0,60 A","range":"0 W až 2,67 kW","cmc":"30 mW"},{"name":"60 V až 130 V; 0,60 A až 1,3 A","range":"0 W až 2,67 kW","cmc":"63 mW"},{"name":"60 V až 130 V; 1,3 A až 2,6 A","range":"0 W až 2,67 kW","cmc":"0,13 W"},{"name":"60 V až 130 V; 2,6 A až 5,2 A","range":"0 W až 2,67 kW","cmc":"0,25 W"},{"name":"60 V až 130 V; 5,2 A až 10 A","range":"0 W až 2,67 kW","cmc":"0,50 W"},{"name":"60 V až 130 V; 10 A až 20,5 A","range":"0 W až 2,67 kW","cmc":"1,0 W"},{"name":"130 V až 270 V; 0,15 A až 0,30 A","range":"0 W až 5,54 kW","cmc":"31 mW"},{"name":"130 V až 270 V; 0,30 A až 0,60 A","range":"0 W až 5,54 kW","cmc":"62 mW"},{"name":"130 V až 270 V; 0,60 A až 1,3 A","range":"0 W až 5,54 kW","cmc":"0,13 W"},{"name":"130 V až 270 V; 1,3 A až 2,6 A","range":"0 W až 5,54 kW","cmc":"0,26 W"},{"name":"130 V až 270 V; 2,6 A až 5,2 A","range":"0 W až 5,54 kW","cmc":"0,51 W"},{"name":"130 V až 270 V; 5,2 A až 10 A","range":"0 W až 5,54 kW","cmc":"1,0 W"},{"name":"130 V až 270 V; 10 A až 20,5 A","range":"0 W až 5,54 kW","cmc":"2,1 W"},{"name":"270 V až 560 V; 0,15 A až 0,30 A","range":"0 W až 11,48 kW","cmc":"63 mW"},{"name":"270 V až 560 V; 0,30 A až 0,60 A","range":"0 W až 11,48 kW","cmc":"0,13 W"},{"name":"270 V až 560 V; 0,60 A až 1,3 A","range":"0 W až 11,48 kW","cmc":"0,26 W"},{"name":"270 V až 560 V; 1,3 A až 2,6 A","range":"0 W až 11,48 kW","cmc":"0,52 W"},{"name":"270 V až 560 V; 2,6 A až 5,2 A","range":"0 W až 11,48 kW","cmc":"1,0 W"},{"name":"270 V až 560 V; 5,2 A až 10 A","range":"0 W až 11,48 kW","cmc":"2,0 W"},{"name":"270 V až 560 V; 10 A až 20,5 A","range":"0 W až 11,48 kW","cmc":"4,2 W"},{"name":"560 V až 720 V; 0,15 A až 0,30 A","range":"0 W až 14,74 kW","cmc":"0,11 W"},{"name":"560 V až 720 V; 0,30 A až 0,60 A","range":"0 W až 14,74 kW","cmc":"0,21 W"},{"name":"560 V až 720 V; 0,60 A až 1,3 A","range":"0 W až 14,74 kW","cmc":"0,44 W"},{"name":"560 V až 720 V; 1,3 A až 2,6 A","range":"0 W až 14,74 kW","cmc":"0,88 W"},{"name":"560 V až 720 V; 2,6 A až 5,2 A","range":"0 W až 14,74 kW","cmc":"1,8 W"},{"name":"560 V až 720 V; 5,2 A až 10 A","range":"0 W až 14,74 kW","cmc":"3,5 W"},{"name":"560 V až 720 V; 10 A až 20,5 A","range":"0 W až 14,74 kW","cmc":"7,1 W"}],"technique":"Watomierz wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard wattmeter: comparison or direct measurement","technique_zh":"标准功率表：比较或直接测量","technique_cs":"Etalonový wattmetr: porovnání nebo přímé měření","techniques":["Watomierz wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard wattmeter: comparison or direct measurement"],"techniques_zh":["标准功率表：比较或直接测量"],"techniques_cs":["Etalonový wattmetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n30 V do 60 V; 0,15 A do 0,30 A od 0 W do 1,23 kW CMC 7,4 mW\n30 V do 60 V; 0,30 A do 0,60 A od 0 W do 1,23 kW CMC 15 mW\n30 V do 60 V; 0,60 A do 1,3 A od 0 W do 1,23 kW CMC 30 mW\n30 V do 60 V; 1,3 A do 2,6 A od 0 W do 1,23 kW CMC 61 mW\n30 V do 60 V; 2,6 A do 5,2 A od 0 W do 1,23 kW CMC 0,12 W\n30 V do 60 V; 5,2 A do 10 A od 0 W do 1,23 kW CMC 0,24 W\n30 V do 60 V; 10 A do 20,5 A od 0 W do 1,23 kW CMC 0,49 W\n60 V do 130 V; 0,15 A do 0,30 A od 0 W do 2,67 kW CMC 15 mW\n60 V do 130 V; 0,30 A do 0,60 A od 0 W do 2,67 kW CMC 30 mW\n60 V do 130 V; 0,60 A do 1,3 A od 0 W do 2,67 kW CMC 63 mW\n60 V do 130 V; 1,3 A do 2,6 A od 0 W do 2,67 kW CMC 0,13 W\n60 V do 130 V; 2,6 A do 5,2 A od 0 W do 2,67 kW CMC 0,25 W\n60 V do 130 V; 5,2 A do 10 A od 0 W do 2,67 kW CMC 0,50 W\n60 V do 130 V; 10 A do 20,5 A od 0 W do 2,67 kW CMC 1,0 W\n130 V do 270 V; 0,15 A do 0,30 A od 0 W do 5,54 kW CMC 31 mW\n130 V do 270 V; 0,30 A do 0,60 A od 0 W do 5,54 kW CMC 62 mW\n130 V do 270 V; 0,60 A do 1,3 A od 0 W do 5,54 kW CMC 0,13 W\n130 V do 270 V; 1,3 A do 2,6 A od 0 W do 5,54 kW CMC 0,26 W\n130 V do 270 V; 2,6 A do 5,2 A od 0 W do 5,54 kW CMC 0,51 W\n130 V do 270 V; 5,2 A do 10 A od 0 W do 5,54 kW CMC 1,0 W\n130 V do 270 V; 10 A do 20,5 A od 0 W do 5,54 kW CMC 2,1 W\n270 V do 560 V; 0,15 A do 0,30 A od 0 W do 11,48 kW CMC 63 mW\n270 V do 560 V; 0,30 A do 0,60 A od 0 W do 11,48 kW CMC 0,13 W\n270 V do 560 V; 0,60 A do 1,3 A od 0 W do 11,48 kW CMC 0,26 W\n270 V do 560 V; 1,3 A do 2,6 A od 0 W do 11,48 kW CMC 0,52 W\n270 V do 560 V; 2,6 A do 5,2 A od 0 W do 11,48 kW CMC 1,0 W\n270 V do 560 V; 5,2 A do 10 A od 0 W do 11,48 kW CMC 2,0 W\n270 V do 560 V; 10 A do 20,5 A od 0 W do 11,48 kW CMC 4,2 W\n560 V do 720 V; 0,15 A do 0,30 A od 0 W do 14,74 kW CMC 0,11 W\n560 V do 720 V; 0,30 A do 0,60 A od 0 W do 14,74 kW CMC 0,21 W\n560 V do 720 V; 0,60 A do 1,3 A od 0 W do 14,74 kW CMC 0,44 W\n560 V do 720 V; 1,3 A do 2,6 A od 0 W do 14,74 kW CMC 0,88 W\n560 V do 720 V; 2,6 A do 5,2 A od 0 W do 14,74 kW CMC 1,8 W\n560 V do 720 V; 5,2 A do 10 A od 0 W do 14,74 kW CMC 3,5 W\n560 V do 720 V; 10 A do 20,5 A od 0 W do 14,74 kW CMC 7,1 W\nWatomierz wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK3, MK7","norm_bases":["MK3","MK7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu przemiennego / watomierze, kalibratory mocy w zakresie częstotliwości od 45 Hz do 65 Hz, współczynnik mocy od 0 do 1 Wzorcowanie – wielkości elektryczne Watomierz wzorcowy: porównanie lub pomiar bezpośredni 30 V do 60 V; 0,15 A do 0,30 A od 0 W do 1,23 kW CMC 7,4 mW 30 V do 60 V; 0,30 A do 0,60 A od 0 W do 1,23 kW CMC 15 mW 30 V do 60 V; 0,60 A do 1,3 A od 0 W do 1,23 kW CMC 30 mW 30 V do 60 V; 1,3 A do 2,6 A od 0 W do 1,23 kW CMC 61 mW 30 V do 60 V; 2,6 A do 5,2 A od 0 W do 1,23 kW CMC 0,12 W 30 V do 60 V; 5,2 A do 10 A od 0 W do 1,23 kW CMC 0,24 W 30 V do 60 V; 10 A do 20,5 A od 0 W do 1,23 kW CMC 0,49 W 60 V do 130 V; 0,15 A do 0,30 A od 0 W do 2,67 kW CMC 15 mW 60 V do 130 V; 0,30 A do 0,60 A od 0 W do 2,67 kW CMC 30 mW 60 V do 130 V; 0,60 A do 1,3 A od 0 W do 2,67 kW CMC 63 mW 60 V do 130 V; 1,3 A do 2,6 A od 0 W do 2,67 kW CMC 0,13 W 60 V do 130 V; 2,6 A do 5,2 A od 0 W do 2,67 kW CMC 0,25 W 60 V do 130 V; 5,2 A do 10 A od 0 W do 2,67 kW CMC 0,50 W 60 V do 130 V; 10 A do 20,5 A od 0 W do 2,67 kW CMC 1,0 W 130 V do 270 V; 0,15 A do 0,30 A od 0 W do 5,54 kW CMC 31 mW 130 V do 270 V; 0,30 A do 0,60 A od 0 W do 5,54 kW CMC 62 mW 130 V do 270 V; 0,60 A do 1,3 A od 0 W do 5,54 kW CMC 0,13 W 130 V do 270 V; 1,3 A do 2,6 A od 0 W do 5,54 kW CMC 0,26 W 130 V do 270 V; 2,6 A do 5,2 A od 0 W do 5,54 kW CMC 0,51 W 130 V do 270 V; 5,2 A do 10 A od 0 W do 5,54 kW CMC 1,0 W 130 V do 270 V; 10 A do 20,5 A od 0 W do 5,54 kW CMC 2,1 W 270 V do 560 V; 0,15 A do 0,30 A od 0 W do 11,48 kW CMC 63 mW 270 V do 560 V; 0,30 A do 0,60 A od 0 W do 11,48 kW CMC 0,13 W 270 V do 560 V; 0,60 A do 1,3 A od 0 W do 11,48 kW CMC 0,26 W 270 V do 560 V; 1,3 A do 2,6 A od 0 W do 11,48 kW CMC 0,52 W 270 V do 560 V; 2,6 A do 5,2 A od 0 W do 11,48 kW CMC 1,0 W 270 V do 560 V; 5,2 A do 10 A od 0 W do 11,48 kW CMC 2,0 W 270 V do 560 V; 10 A do 20,5 A od 0 W do 11,48 kW CMC 4,2 W 560 V do 720 V; 0,15 A do 0,30 A od 0 W do 14,74 kW CMC 0,11 W 560 V do 720 V; 0,30 A do 0,60 A od 0 W do 14,74 kW CMC 0,21 W 560 V do 720 V; 0,60 A do 1,3 A od 0 W do 14,74 kW CMC 0,44 W 560 V do 720 V; 1,3 A do 2,6 A od 0 W do 14,74 kW CMC 0,88 W 560 V do 720 V; 2,6 A do 5,2 A od 0 W do 14,74 kW CMC 1,8 W 560 V do 720 V; 5,2 A do 10 A od 0 W do 14,74 kW CMC 3,5 W 560 V do 720 V; 10 A do 20,5 A od 0 W do 14,74 kW CMC 7,1 W Střídavý výkon / Wattmetry, kalibrátory výkonu v rozsahu kmitočtů 45 Hz až 65 Hz, účiník 0 až 1 Kalibrace – elektrické veličiny Etalonový wattmetr: porovnání nebo přímé měření 30 V až 60 V; 0,15 A až 0,30 A 0 W až 1,23 kW CMC 7,4 mW 30 V až 60 V; 0,30 A až 0,60 A 0 W až 1,23 kW CMC 15 mW 30 V až 60 V; 0,60 A až 1,3 A 0 W až 1,23 kW CMC 30 mW 30 V až 60 V; 1,3 A až 2,6 A 0 W až 1,23 kW CMC 61 mW 30 V až 60 V; 2,6 A až 5,2 A 0 W až 1,23 kW CMC 0,12 W 30 V až 60 V; 5,2 A až 10 A 0 W až 1,23 kW CMC 0,24 W 30 V až 60 V; 10 A až 20,5 A 0 W až 1,23 kW CMC 0,49 W 60 V až 130 V; 0,15 A až 0,30 A 0 W až 2,67 kW CMC 15 mW 60 V až 130 V; 0,30 A až 0,60 A 0 W až 2,67 kW CMC 30 mW 60 V až 130 V; 0,60 A až 1,3 A 0 W až 2,67 kW CMC 63 mW 60 V až 130 V; 1,3 A až 2,6 A 0 W až 2,67 kW CMC 0,13 W 60 V až 130 V; 2,6 A až 5,2 A 0 W až 2,67 kW CMC 0,25 W 60 V až 130 V; 5,2 A až 10 A 0 W až 2,67 kW CMC 0,50 W 60 V až 130 V; 10 A až 20,5 A 0 W až 2,67 kW CMC 1,0 W 130 V až 270 V; 0,15 A až 0,30 A 0 W až 5,54 kW CMC 31 mW 130 V až 270 V; 0,30 A až 0,60 A 0 W až 5,54 kW CMC 62 mW 130 V až 270 V; 0,60 A až 1,3 A 0 W až 5,54 kW CMC 0,13 W 130 V až 270 V; 1,3 A až 2,6 A 0 W až 5,54 kW CMC 0,26 W 130 V až 270 V; 2,6 A až 5,2 A 0 W až 5,54 kW CMC 0,51 W 130 V až 270 V; 5,2 A až 10 A 0 W až 5,54 kW CMC 1,0 W 130 V až 270 V; 10 A až 20,5 A 0 W až 5,54 kW CMC 2,1 W 270 V až 560 V; 0,15 A až 0,30 A 0 W až 11,48 kW CMC 63 mW 270 V až 560 V; 0,30 A až 0,60 A 0 W až 11,48 kW CMC 0,13 W 270 V až 560 V; 0,60 A až 1,3 A 0 W až 11,48 kW CMC 0,26 W 270 V až 560 V; 1,3 A až 2,6 A 0 W až 11,48 kW CMC 0,52 W 270 V až 560 V; 2,6 A až 5,2 A 0 W až 11,48 kW CMC 1,0 W 270 V až 560 V; 5,2 A až 10 A 0 W až 11,48 kW CMC 2,0 W 270 V až 560 V; 10 A až 20,5 A 0 W až 11,48 kW CMC 4,2 W 560 V až 720 V; 0,15 A až 0,30 A 0 W až 14,74 kW CMC 0,11 W 560 V až 720 V; 0,30 A až 0,60 A 0 W až 14,74 kW CMC 0,21 W 560 V až 720 V; 0,60 A až 1,3 A 0 W až 14,74 kW CMC 0,44 W 560 V až 720 V; 1,3 A až 2,6 A 0 W až 14,74 kW CMC 0,88 W 560 V až 720 V; 2,6 A až 5,2 A 0 W až 14,74 kW CMC 1,8 W 560 V až 720 V; 5,2 A až 10 A 0 W až 14,74 kW CMC 3,5 W 560 V až 720 V; 10 A až 20,5 A 0 W až 14,74 kW CMC 7,1 W MK3, MK7 Moc pradu przemiennego / watomierze, kalibratory mocy w zakresie czestotliwosci od 45 Hz do 65 Hz, wspolczynnik mocy od 0 do 1 Wzorcowanie – wielkosci elektryczne Watomierz wzorcowy: porownanie lub pomiar bezposredni 30 V do 60 V; 0,15 A do 0,30 A od 0 W do 1,23 kW CMC 7,4 mW 30 V do 60 V; 0,30 A do 0,60 A od 0 W do 1,23 kW CMC 15 mW 30 V do 60 V; 0,60 A do 1,3 A od 0 W do 1,23 kW CMC 30 mW 30 V do 60 V; 1,3 A do 2,6 A od 0 W do 1,23 kW CMC 61 mW 30 V do 60 V; 2,6 A do 5,2 A od 0 W do 1,23 kW CMC 0,12 W 30 V do 60 V; 5,2 A do 10 A od 0 W do 1,23 kW CMC 0,24 W 30 V do 60 V; 10 A do 20,5 A od 0 W do 1,23 kW CMC 0,49 W 60 V do 130 V; 0,15 A do 0,30 A od 0 W do 2,67 kW CMC 15 mW 60 V do 130 V; 0,30 A do 0,60 A od 0 W do 2,67 kW CMC 30 mW 60 V do 130 V; 0,60 A do 1,3 A od 0 W do 2,67 kW CMC 63 mW 60 V do 130 V; 1,3 A do 2,6 A od 0 W do 2,67 kW CMC 0,13 W 60 V do 130 V; 2,6 A do 5,2 A od 0 W do 2,67 kW CMC 0,25 W 60 V do 130 V; 5,2 A do 10 A od 0 W do 2,67 kW CMC 0,50 W 60 V do 130 V; 10 A do 20,5 A od 0 W do 2,67 kW CMC 1,0 W 130 V do 270 V; 0,15 A do 0,30 A od 0 W do 5,54 kW CMC 31 mW 130 V do 270 V; 0,30 A do 0,60 A od 0 W do 5,54 kW CMC 62 mW 130 V do 270 V; 0,60 A do 1,3 A od 0 W do 5,54 kW CMC 0,13 W 130 V do 270 V; 1,3 A do 2,6 A od 0 W do 5,54 kW CMC 0,26 W 130 V do 270 V; 2,6 A do 5,2 A od 0 W do 5,54 kW CMC 0,51 W 130 V do 270 V; 5,2 A do 10 A od 0 W do 5,54 kW CMC 1,0 W 130 V do 270 V; 10 A do 20,5 A od 0 W do 5,54 kW CMC 2,1 W 270 V do 560 V; 0,15 A do 0,30 A od 0 W do 11,48 kW CMC 63 mW 270 V do 560 V; 0,30 A do 0,60 A od 0 W do 11,48 kW CMC 0,13 W 270 V do 560 V; 0,60 A do 1,3 A od 0 W do 11,48 kW CMC 0,26 W 270 V do 560 V; 1,3 A do 2,6 A od 0 W do 11,48 kW CMC 0,52 W 270 V do 560 V; 2,6 A do 5,2 A od 0 W do 11,48 kW CMC 1,0 W 270 V do 560 V; 5,2 A do 10 A od 0 W do 11,48 kW CMC 2,0 W 270 V do 560 V; 10 A do 20,5 A od 0 W do 11,48 kW CMC 4,2 W 560 V do 720 V; 0,15 A do 0,30 A od 0 W do 14,74 kW CMC 0,11 W 560 V do 720 V; 0,30 A do 0,60 A od 0 W do 14,74 kW CMC 0,21 W 560 V do 720 V; 0,60 A do 1,3 A od 0 W do 14,74 kW CMC 0,44 W 560 V do 720 V; 1,3 A do 2,6 A od 0 W do 14,74 kW CMC 0,88 W 560 V do 720 V; 2,6 A do 5,2 A od 0 W do 14,74 kW CMC 1,8 W 560 V do 720 V; 5,2 A do 10 A od 0 W do 14,74 kW CMC 3,5 W 560 V do 720 V; 10 A do 20,5 A od 0 W do 14,74 kW CMC 7,1 W Stridavy vykon / Wattmetry, kalibratory vykonu v rozsahu kmitoctu 45 Hz az 65 Hz, ucinik 0 az 1 Kalibrace – elektricke veliciny Etalonovy wattmetr: porovnani nebo prime mereni 30 V az 60 V; 0,15 A az 0,30 A 0 W az 1,23 kW CMC 7,4 mW 30 V az 60 V; 0,30 A az 0,60 A 0 W az 1,23 kW CMC 15 mW 30 V az 60 V; 0,60 A az 1,3 A 0 W az 1,23 kW CMC 30 mW 30 V az 60 V; 1,3 A az 2,6 A 0 W az 1,23 kW CMC 61 mW 30 V az 60 V; 2,6 A az 5,2 A 0 W az 1,23 kW CMC 0,12 W 30 V az 60 V; 5,2 A az 10 A 0 W az 1,23 kW CMC 0,24 W 30 V az 60 V; 10 A az 20,5 A 0 W az 1,23 kW CMC 0,49 W 60 V az 130 V; 0,15 A az 0,30 A 0 W az 2,67 kW CMC 15 mW 60 V az 130 V; 0,30 A az 0,60 A 0 W az 2,67 kW CMC 30 mW 60 V az 130 V; 0,60 A az 1,3 A 0 W az 2,67 kW CMC 63 mW 60 V az 130 V; 1,3 A az 2,6 A 0 W az 2,67 kW CMC 0,13 W 60 V az 130 V; 2,6 A az 5,2 A 0 W az 2,67 kW CMC 0,25 W 60 V az 130 V; 5,2 A az 10 A 0 W az 2,67 kW CMC 0,50 W 60 V az 130 V; 10 A az 20,5 A 0 W az 2,67 kW CMC 1,0 W 130 V az 270 V; 0,15 A az 0,30 A 0 W az 5,54 kW CMC 31 mW 130 V az 270 V; 0,30 A az 0,60 A 0 W az 5,54 kW CMC 62 mW 130 V az 270 V; 0,60 A az 1,3 A 0 W az 5,54 kW CMC 0,13 W 130 V az 270 V; 1,3 A az 2,6 A 0 W az 5,54 kW CMC 0,26 W 130 V az 270 V; 2,6 A az 5,2 A 0 W az 5,54 kW CMC 0,51 W 130 V az 270 V; 5,2 A az 10 A 0 W az 5,54 kW CMC 1,0 W 130 V az 270 V; 10 A az 20,5 A 0 W az 5,54 kW CMC 2,1 W 270 V az 560 V; 0,15 A az 0,30 A 0 W az 11,48 kW CMC 63 mW 270 V az 560 V; 0,30 A az 0,60 A 0 W az 11,48 kW CMC 0,13 W 270 V az 560 V; 0,60 A az 1,3 A 0 W az 11,48 kW CMC 0,26 W 270 V az 560 V; 1,3 A az 2,6 A 0 W az 11,48 kW CMC 0,52 W 270 V az 560 V; 2,6 A az 5,2 A 0 W az 11,48 kW CMC 1,0 W 270 V az 560 V; 5,2 A az 10 A 0 W az 11,48 kW CMC 2,0 W 270 V az 560 V; 10 A az 20,5 A 0 W az 11,48 kW CMC 4,2 W 560 V az 720 V; 0,15 A az 0,30 A 0 W az 14,74 kW CMC 0,11 W 560 V az 720 V; 0,30 A az 0,60 A 0 W az 14,74 kW CMC 0,21 W 560 V az 720 V; 0,60 A az 1,3 A 0 W az 14,74 kW CMC 0,44 W 560 V az 720 V; 1,3 A az 2,6 A 0 W az 14,74 kW CMC 0,88 W 560 V az 720 V; 2,6 A az 5,2 A 0 W az 14,74 kW CMC 1,8 W 560 V az 720 V; 5,2 A az 10 A 0 W az 14,74 kW CMC 3,5 W 560 V az 720 V; 10 A az 20,5 A 0 W az 14,74 kW CMC 7,1 W MK3, MK7","search_en":"AC power / Wattmeters, power calibrators in the frequency range 45 Hz to 65 Hz, power factor 0 to 1 Calibration – electrical quantities Standard wattmeter: comparison or direct measurement 30 V to 60 V; 0,15 A to 0,30 A 0 W to 1,23 kW CMC 7,4 mW 30 V to 60 V; 0,30 A to 0,60 A 0 W to 1,23 kW CMC 15 mW 30 V to 60 V; 0,60 A to 1,3 A 0 W to 1,23 kW CMC 30 mW 30 V to 60 V; 1,3 A to 2,6 A 0 W to 1,23 kW CMC 61 mW 30 V to 60 V; 2,6 A to 5,2 A 0 W to 1,23 kW CMC 0,12 W 30 V to 60 V; 5,2 A to 10 A 0 W to 1,23 kW CMC 0,24 W 30 V to 60 V; 10 A to 20,5 A 0 W to 1,23 kW CMC 0,49 W 60 V to 130 V; 0,15 A to 0,30 A 0 W to 2,67 kW CMC 15 mW 60 V to 130 V; 0,30 A to 0,60 A 0 W to 2,67 kW CMC 30 mW 60 V to 130 V; 0,60 A to 1,3 A 0 W to 2,67 kW CMC 63 mW 60 V to 130 V; 1,3 A to 2,6 A 0 W to 2,67 kW CMC 0,13 W 60 V to 130 V; 2,6 A to 5,2 A 0 W to 2,67 kW CMC 0,25 W 60 V to 130 V; 5,2 A to 10 A 0 W to 2,67 kW CMC 0,50 W 60 V to 130 V; 10 A to 20,5 A 0 W to 2,67 kW CMC 1,0 W 130 V to 270 V; 0,15 A to 0,30 A 0 W to 5,54 kW CMC 31 mW 130 V to 270 V; 0,30 A to 0,60 A 0 W to 5,54 kW CMC 62 mW 130 V to 270 V; 0,60 A to 1,3 A 0 W to 5,54 kW CMC 0,13 W 130 V to 270 V; 1,3 A to 2,6 A 0 W to 5,54 kW CMC 0,26 W 130 V to 270 V; 2,6 A to 5,2 A 0 W to 5,54 kW CMC 0,51 W 130 V to 270 V; 5,2 A to 10 A 0 W to 5,54 kW CMC 1,0 W 130 V to 270 V; 10 A to 20,5 A 0 W to 5,54 kW CMC 2,1 W 270 V to 560 V; 0,15 A to 0,30 A 0 W to 11,48 kW CMC 63 mW 270 V to 560 V; 0,30 A to 0,60 A 0 W to 11,48 kW CMC 0,13 W 270 V to 560 V; 0,60 A to 1,3 A 0 W to 11,48 kW CMC 0,26 W 270 V to 560 V; 1,3 A to 2,6 A 0 W to 11,48 kW CMC 0,52 W 270 V to 560 V; 2,6 A to 5,2 A 0 W to 11,48 kW CMC 1,0 W 270 V to 560 V; 5,2 A to 10 A 0 W to 11,48 kW CMC 2,0 W 270 V to 560 V; 10 A to 20,5 A 0 W to 11,48 kW CMC 4,2 W 560 V to 720 V; 0,15 A to 0,30 A 0 W to 14,74 kW CMC 0,11 W 560 V to 720 V; 0,30 A to 0,60 A 0 W to 14,74 kW CMC 0,21 W 560 V to 720 V; 0,60 A to 1,3 A 0 W to 14,74 kW CMC 0,44 W 560 V to 720 V; 1,3 A to 2,6 A 0 W to 14,74 kW CMC 0,88 W 560 V to 720 V; 2,6 A to 5,2 A 0 W to 14,74 kW CMC 1,8 W 560 V to 720 V; 5,2 A to 10 A 0 W to 14,74 kW CMC 3,5 W 560 V to 720 V; 10 A to 20,5 A 0 W to 14,74 kW CMC 7,1 W MK3, MK7","search_zh":"交流功率 / 功率表、功率校准器，频率范围 45 Hz 至 65 Hz，功率因数 0 至 1 校准 – 电学量 标准功率表：比较或直接测量 30 V 至 60 V；0,15 A 至 0,30 A 0 W 至 1,23 kW CMC 7,4 mW 30 V 至 60 V；0,30 A 至 0,60 A 0 W 至 1,23 kW CMC 15 mW 30 V 至 60 V；0,60 A 至 1,3 A 0 W 至 1,23 kW CMC 30 mW 30 V 至 60 V；1,3 A 至 2,6 A 0 W 至 1,23 kW CMC 61 mW 30 V 至 60 V；2,6 A 至 5,2 A 0 W 至 1,23 kW CMC 0,12 W 30 V 至 60 V；5,2 A 至 10 A 0 W 至 1,23 kW CMC 0,24 W 30 V 至 60 V；10 A 至 20,5 A 0 W 至 1,23 kW CMC 0,49 W 60 V 至 130 V；0,15 A 至 0,30 A 0 W 至 2,67 kW CMC 15 mW 60 V 至 130 V；0,30 A 至 0,60 A 0 W 至 2,67 kW CMC 30 mW 60 V 至 130 V；0,60 A 至 1,3 A 0 W 至 2,67 kW CMC 63 mW 60 V 至 130 V；1,3 A 至 2,6 A 0 W 至 2,67 kW CMC 0,13 W 60 V 至 130 V；2,6 A 至 5,2 A 0 W 至 2,67 kW CMC 0,25 W 60 V 至 130 V；5,2 A 至 10 A 0 W 至 2,67 kW CMC 0,50 W 60 V 至 130 V；10 A 至 20,5 A 0 W 至 2,67 kW CMC 1,0 W 130 V 至 270 V；0,15 A 至 0,30 A 0 W 至 5,54 kW CMC 31 mW 130 V 至 270 V；0,30 A 至 0,60 A 0 W 至 5,54 kW CMC 62 mW 130 V 至 270 V；0,60 A 至 1,3 A 0 W 至 5,54 kW CMC 0,13 W 130 V 至 270 V；1,3 A 至 2,6 A 0 W 至 5,54 kW CMC 0,26 W 130 V 至 270 V；2,6 A 至 5,2 A 0 W 至 5,54 kW CMC 0,51 W 130 V 至 270 V；5,2 A 至 10 A 0 W 至 5,54 kW CMC 1,0 W 130 V 至 270 V；10 A 至 20,5 A 0 W 至 5,54 kW CMC 2,1 W 270 V 至 560 V；0,15 A 至 0,30 A 0 W 至 11,48 kW CMC 63 mW 270 V 至 560 V；0,30 A 至 0,60 A 0 W 至 11,48 kW CMC 0,13 W 270 V 至 560 V；0,60 A 至 1,3 A 0 W 至 11,48 kW CMC 0,26 W 270 V 至 560 V；1,3 A 至 2,6 A 0 W 至 11,48 kW CMC 0,52 W 270 V 至 560 V；2,6 A 至 5,2 A 0 W 至 11,48 kW CMC 1,0 W 270 V 至 560 V；5,2 A 至 10 A 0 W 至 11,48 kW CMC 2,0 W 270 V 至 560 V；10 A 至 20,5 A 0 W 至 11,48 kW CMC 4,2 W 560 V 至 720 V；0,15 A 至 0,30 A 0 W 至 14,74 kW CMC 0,11 W 560 V 至 720 V；0,30 A 至 0,60 A 0 W 至 14,74 kW CMC 0,21 W 560 V 至 720 V；0,60 A 至 1,3 A 0 W 至 14,74 kW CMC 0,44 W 560 V 至 720 V；1,3 A 至 2,6 A 0 W 至 14,74 kW CMC 0,88 W 560 V 至 720 V；2,6 A 至 5,2 A 0 W 至 14,74 kW CMC 1,8 W 560 V 至 720 V；5,2 A 至 10 A 0 W 至 14,74 kW CMC 3,5 W 560 V 至 720 V；10 A 至 20,5 A 0 W 至 14,74 kW CMC 7,1 W MK3, MK7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0a264bc0164bd3464fc9b338","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"24","test_object":"Moc prądu przemiennego / źródła i kalibratory mocy w zakresie częstotliwości od 45 Hz do 65 Hz, współczynnik mocy od 0 do 1","test_object_en":"AC power / Power sources and calibrators in the frequency range 45 Hz to 65 Hz, power factor 0 to 1","test_object_zh":"交流功率 / 功率源和功率校准器，频率范围 45 Hz 至 65 Hz，功率因数 0 至 1","test_object_cs":"Střídavý výkon / Zdroje a kalibrátory výkonu v rozsahu kmitočtů 45 Hz až 65 Hz, účiník 0 až 1","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"6 V do 720 V; 20,5 A do 120 A","range":"od 0 W do 86,4 kW","cmc":"1,8 mW/VA"}],"parameters_en":[{"name":"6 V to 720 V; 20,5 A to 120 A","range":"0 W to 86,4 kW","cmc":"1,8 mW/VA"}],"parameters_zh":[{"name":"6 V 至 720 V；20,5 A 至 120 A","range":"0 W 至 86,4 kW","cmc":"1,8 mW/VA"}],"parameters_cs":[{"name":"6 V až 720 V; 20,5 A až 120 A","range":"0 W až 86,4 kW","cmc":"1,8 mW/VA"}],"technique":"Pomiar watomierzem wzorcowym i przekładnikiem prądowym","technique_en":"Measurement by a standard wattmeter and a current transformer","technique_zh":"用标准功率表和电流互感器测量","technique_cs":"Měření etalonovým wattmetrem a proudovým transformátorem","techniques":["Pomiar watomierzem wzorcowym i przekładnikiem prądowym"],"techniques_en":["Measurement by a standard wattmeter and a current transformer"],"techniques_zh":["用标准功率表和电流互感器测量"],"techniques_cs":["Měření etalonovým wattmetrem a proudovým transformátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n6 V do 720 V; 20,5 A do 120 A od 0 W do 86,4 kW CMC 1,8 mW/VA\nPomiar watomierzem wzorcowym i przekładnikiem prądowym","reference":"MK7","norm_bases":["MK7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu przemiennego / źródła i kalibratory mocy w zakresie częstotliwości od 45 Hz do 65 Hz, współczynnik mocy od 0 do 1 Wzorcowanie – wielkości elektryczne Pomiar watomierzem wzorcowym i przekładnikiem prądowym 6 V do 720 V; 20,5 A do 120 A od 0 W do 86,4 kW CMC 1,8 mW/VA Střídavý výkon / Zdroje a kalibrátory výkonu v rozsahu kmitočtů 45 Hz až 65 Hz, účiník 0 až 1 Kalibrace – elektrické veličiny Měření etalonovým wattmetrem a proudovým transformátorem 6 V až 720 V; 20,5 A až 120 A 0 W až 86,4 kW CMC 1,8 mW/VA MK7 Moc pradu przemiennego / zrodla i kalibratory mocy w zakresie czestotliwosci od 45 Hz do 65 Hz, wspolczynnik mocy od 0 do 1 Wzorcowanie – wielkosci elektryczne Pomiar watomierzem wzorcowym i przekladnikiem pradowym 6 V do 720 V; 20,5 A do 120 A od 0 W do 86,4 kW CMC 1,8 mW/VA Stridavy vykon / Zdroje a kalibratory vykonu v rozsahu kmitoctu 45 Hz az 65 Hz, ucinik 0 az 1 Kalibrace – elektricke veliciny Mereni etalonovym wattmetrem a proudovym transformatorem 6 V az 720 V; 20,5 A az 120 A 0 W az 86,4 kW CMC 1,8 mW/VA MK7","search_en":"AC power / Power sources and calibrators in the frequency range 45 Hz to 65 Hz, power factor 0 to 1 Calibration – electrical quantities Measurement by a standard wattmeter and a current transformer 6 V to 720 V; 20,5 A to 120 A 0 W to 86,4 kW CMC 1,8 mW/VA MK7","search_zh":"交流功率 / 功率源和功率校准器，频率范围 45 Hz 至 65 Hz，功率因数 0 至 1 校准 – 电学量 用标准功率表和电流互感器测量 6 V 至 720 V；20,5 A 至 120 A 0 W 至 86,4 kW CMC 1,8 mW/VA MK7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"670cf25c1778312036958d59","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"25","test_object":"Współczynnik mocy / watomierze, fazomierze, kalibratory mocy","test_object_en":"Power factor / Wattmeters, phase meters, power calibrators","test_object_zh":"功率因数 / 功率表、相位表、功率校准器","test_object_cs":"Účiník / Wattmetry, fázoměry, kalibrátory výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 0,0 do 0,8","cmc":"0,0012 (abs.)"},{"name":"45 Hz do 65 Hz","range":"od 0,8 do 1,0","cmc":"0,0007 (abs.)"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"0,0 to 0,8","cmc":"0,0012 (abs.)"},{"name":"45 Hz to 65 Hz","range":"0,8 to 1,0","cmc":"0,0007 (abs.)"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"0,0 至 0,8","cmc":"0,0012 (abs.)"},{"name":"45 Hz 至 65 Hz","range":"0,8 至 1,0","cmc":"0,0007 (abs.)"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"0,0 až 0,8","cmc":"0,0012 (abs.)"},{"name":"45 Hz až 65 Hz","range":"0,8 až 1,0","cmc":"0,0007 (abs.)"}],"technique":"Watomierz wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard wattmeter: comparison or direct measurement","technique_zh":"标准功率表：比较或直接测量","technique_cs":"Etalonovým wattmetr: porovnání nebo přímé měření","techniques":["Watomierz wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard wattmeter: comparison or direct measurement"],"techniques_zh":["标准功率表：比较或直接测量"],"techniques_cs":["Etalonovým wattmetr: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 65 Hz od 0,0 do 0,8 CMC 0,0012 (abs.)\n45 Hz do 65 Hz od 0,8 do 1,0 CMC 0,0007 (abs.)\nWatomierz wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK7","norm_bases":["MK7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik mocy / watomierze, fazomierze, kalibratory mocy Wzorcowanie – wielkości elektryczne Watomierz wzorcowy: porównanie lub pomiar bezpośredni 45 Hz do 65 Hz od 0,0 do 0,8 CMC 0,0012 (abs.) 45 Hz do 65 Hz od 0,8 do 1,0 CMC 0,0007 (abs.) Účiník / Wattmetry, fázoměry, kalibrátory výkonu Kalibrace – elektrické veličiny Etalonovým wattmetr: porovnání nebo přímé měření 45 Hz až 65 Hz 0,0 až 0,8 CMC 0,0012 (abs.) 45 Hz až 65 Hz 0,8 až 1,0 CMC 0,0007 (abs.) MK7 Wspolczynnik mocy / watomierze, fazomierze, kalibratory mocy Wzorcowanie – wielkosci elektryczne Watomierz wzorcowy: porownanie lub pomiar bezposredni 45 Hz do 65 Hz od 0,0 do 0,8 CMC 0,0012 (abs.) 45 Hz do 65 Hz od 0,8 do 1,0 CMC 0,0007 (abs.) Ucinik / Wattmetry, fazomery, kalibratory vykonu Kalibrace – elektricke veliciny Etalonovym wattmetr: porovnani nebo prime mereni 45 Hz az 65 Hz 0,0 az 0,8 CMC 0,0012 (abs.) 45 Hz az 65 Hz 0,8 az 1,0 CMC 0,0007 (abs.) MK7","search_en":"Power factor / Wattmeters, phase meters, power calibrators Calibration – electrical quantities Standard wattmeter: comparison or direct measurement 45 Hz to 65 Hz 0,0 to 0,8 CMC 0,0012 (abs.) 45 Hz to 65 Hz 0,8 to 1,0 CMC 0,0007 (abs.) MK7","search_zh":"功率因数 / 功率表、相位表、功率校准器 校准 – 电学量 标准功率表：比较或直接测量 45 Hz 至 65 Hz 0,0 至 0,8 CMC 0,0012 (abs.) 45 Hz 至 65 Hz 0,8 至 1,0 CMC 0,0007 (abs.) MK7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4203d410fb581265143f1e2","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"26","test_object":"Migotanie (flicker) / analizatory sieci, generatory migotania z modulacją prostokątną","test_object_en":"Flicker / Network analysers, flicker generators with rectangular modulation","test_object_zh":"闪变 / 电网分析仪、矩形调制闪变发生器","test_object_cs":"Flikr / Analyzátory sítě, generátory flikru s obdélníkovou modulací","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz i 60 Hz","range":"od 1 Pst do 5 Pst","cmc":"1,0 %"}],"parameters_en":[{"name":"50 Hz and 60 Hz","range":"1 Pst to 5 Pst","cmc":"1,0 %"}],"parameters_zh":[{"name":"50 Hz 和 60 Hz","range":"1 Pst 至 5 Pst","cmc":"1,0 %"}],"parameters_cs":[{"name":"50 Hz a 60 Hz","range":"1 Pst až 5 Pst","cmc":"1,0 %"}],"technique":"Multimetr i oscyloskop wzorcowy: porównanie za pomocą kalibratora migotania lub pomiar bezpośredni","technique_en":"Standard multimeter and oscilloscope: comparison using a flicker calibrator or direct measurement","technique_zh":"标准万用表和示波器：借助闪变校准器比较或直接测量","technique_cs":"Etalonovým multimetr a osciloskop: porovnání pomocí kalibrátoru flikru nebo přímé měření","techniques":["Multimetr i oscyloskop wzorcowy: porównanie za pomocą kalibratora migotania lub pomiar bezpośredni"],"techniques_en":["Standard multimeter and oscilloscope: comparison using a flicker calibrator or direct measurement"],"techniques_zh":["标准万用表和示波器：借助闪变校准器比较或直接测量"],"techniques_cs":["Etalonovým multimetr a osciloskop: porovnání pomocí kalibrátoru flikru nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz i 60 Hz od 1 Pst do 5 Pst CMC 1,0 %\nMultimetr i oscyloskop wzorcowy: porównanie za pomocą kalibratora migotania lub pomiar bezpośredni","reference":"MK11","norm_bases":["MK11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Migotanie (flicker) / analizatory sieci, generatory migotania z modulacją prostokątną Wzorcowanie – wielkości elektryczne Multimetr i oscyloskop wzorcowy: porównanie za pomocą kalibratora migotania lub pomiar bezpośredni 50 Hz i 60 Hz od 1 Pst do 5 Pst CMC 1,0 % Flikr / Analyzátory sítě, generátory flikru s obdélníkovou modulací Kalibrace – elektrické veličiny Etalonovým multimetr a osciloskop: porovnání pomocí kalibrátoru flikru nebo přímé měření 50 Hz a 60 Hz 1 Pst až 5 Pst CMC 1,0 % MK11 Migotanie (flicker) / analizatory sieci, generatory migotania z modulacja prostokatna Wzorcowanie – wielkosci elektryczne Multimetr i oscyloskop wzorcowy: porownanie za pomoca kalibratora migotania lub pomiar bezposredni 50 Hz i 60 Hz od 1 Pst do 5 Pst CMC 1,0 % Flikr / Analyzatory site, generatory flikru s obdelnikovou modulaci Kalibrace – elektricke veliciny Etalonovym multimetr a osciloskop: porovnani pomoci kalibratoru flikru nebo prime mereni 50 Hz a 60 Hz 1 Pst az 5 Pst CMC 1,0 % MK11","search_en":"Flicker / Network analysers, flicker generators with rectangular modulation Calibration – electrical quantities Standard multimeter and oscilloscope: comparison using a flicker calibrator or direct measurement 50 Hz and 60 Hz 1 Pst to 5 Pst CMC 1,0 % MK11","search_zh":"闪变 / 电网分析仪、矩形调制闪变发生器 校准 – 电学量 标准万用表和示波器：借助闪变校准器比较或直接测量 50 Hz 和 60 Hz 1 Pst 至 5 Pst CMC 1,0 % MK11","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aa7adc53137de5422495a567","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"27","test_object":"Moc w.cz. / generatory sygnałowe, inne urządzenia w.cz.","test_object_en":"RF power / Signal generators, other RF equipment","test_object_zh":"射频功率 / 信号发生器、其他射频设备","test_object_cs":"Vf výkon / Signální generátory, další vf zařízení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"9 kHz do 100 MHz","range":"od 0,2 nW do 200 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz do 4 GHz","range":"od 0,2 nW do 200 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz do 6 GHz","range":"od 0,2 nW do 200 mW","cmc":"1,9 % + 0,1 nW"}],"parameters_en":[{"name":"9 kHz to 100 MHz","range":"0,2 nW to 200 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz to 4 GHz","range":"0,2 nW to 200 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz to 6 GHz","range":"0,2 nW to 200 mW","cmc":"1,9 % + 0,1 nW"}],"parameters_zh":[{"name":"9 kHz 至 100 MHz","range":"0,2 nW 至 200 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz 至 4 GHz","range":"0,2 nW 至 200 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz 至 6 GHz","range":"0,2 nW 至 200 mW","cmc":"1,9 % + 0,1 nW"}],"parameters_cs":[{"name":"9 kHz až 100 MHz","range":"0,2 nW až 200 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz až 4 GHz","range":"0,2 nW až 200 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz až 6 GHz","range":"0,2 nW až 200 mW","cmc":"1,9 % + 0,1 nW"}],"technique":"Pomiar bezpośredni wzorcowym watomierzem w.cz.","technique_en":"Direct measurement by a standard RF power meter","technique_zh":"用标准射频功率计直接测量","technique_cs":"Přímé měření etalonovým vf wattmetrem","techniques":["Pomiar bezpośredni wzorcowym watomierzem w.cz."],"techniques_en":["Direct measurement by a standard RF power meter"],"techniques_zh":["用标准射频功率计直接测量"],"techniques_cs":["Přímé měření etalonovým vf wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n9 kHz do 100 MHz od 0,2 nW do 200 mW CMC 1,3 % + 0,1 nW\n100 MHz do 4 GHz od 0,2 nW do 200 mW CMC 1,5 % + 0,1 nW\n4 GHz do 6 GHz od 0,2 nW do 200 mW CMC 1,9 % + 0,1 nW\nPomiar bezpośredni wzorcowym watomierzem w.cz.","reference":"MK16, MK17","norm_bases":["MK16","MK17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc w.cz. / generatory sygnałowe, inne urządzenia w.cz. Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowym watomierzem w.cz. 9 kHz do 100 MHz od 0,2 nW do 200 mW CMC 1,3 % + 0,1 nW 100 MHz do 4 GHz od 0,2 nW do 200 mW CMC 1,5 % + 0,1 nW 4 GHz do 6 GHz od 0,2 nW do 200 mW CMC 1,9 % + 0,1 nW Vf výkon / Signální generátory, další vf zařízení Kalibrace – elektrické veličiny Přímé měření etalonovým vf wattmetrem 9 kHz až 100 MHz 0,2 nW až 200 mW CMC 1,3 % + 0,1 nW 100 MHz až 4 GHz 0,2 nW až 200 mW CMC 1,5 % + 0,1 nW 4 GHz až 6 GHz 0,2 nW až 200 mW CMC 1,9 % + 0,1 nW MK16, MK17 Moc w.cz. / generatory sygnalowe, inne urzadzenia w.cz. Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowym watomierzem w.cz. 9 kHz do 100 MHz od 0,2 nW do 200 mW CMC 1,3 % + 0,1 nW 100 MHz do 4 GHz od 0,2 nW do 200 mW CMC 1,5 % + 0,1 nW 4 GHz do 6 GHz od 0,2 nW do 200 mW CMC 1,9 % + 0,1 nW Vf vykon / Signalni generatory, dalsi vf zarizeni Kalibrace – elektricke veliciny Prime mereni etalonovym vf wattmetrem 9 kHz az 100 MHz 0,2 nW az 200 mW CMC 1,3 % + 0,1 nW 100 MHz az 4 GHz 0,2 nW az 200 mW CMC 1,5 % + 0,1 nW 4 GHz az 6 GHz 0,2 nW az 200 mW CMC 1,9 % + 0,1 nW MK16, MK17","search_en":"RF power / Signal generators, other RF equipment Calibration – electrical quantities Direct measurement by a standard RF power meter 9 kHz to 100 MHz 0,2 nW to 200 mW CMC 1,3 % + 0,1 nW 100 MHz to 4 GHz 0,2 nW to 200 mW CMC 1,5 % + 0,1 nW 4 GHz to 6 GHz 0,2 nW to 200 mW CMC 1,9 % + 0,1 nW MK16, MK17","search_zh":"射频功率 / 信号发生器、其他射频设备 校准 – 电学量 用标准射频功率计直接测量 9 kHz 至 100 MHz 0,2 nW 至 200 mW CMC 1,3 % + 0,1 nW 100 MHz 至 4 GHz 0,2 nW 至 200 mW CMC 1,5 % + 0,1 nW 4 GHz 至 6 GHz 0,2 nW 至 200 mW CMC 1,9 % + 0,1 nW MK16, MK17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f8430e1d49e9efca99325f52","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"27","test_object":"Moc w.cz. / watomierze w.cz., oscyloskopy, inne urządzenia w.cz.","test_object_en":"RF power / RF power meters, oscilloscopes, other RF equipment","test_object_zh":"射频功率 / 射频功率计、示波器、其他射频设备","test_object_cs":"Vf výkon / vf wattmetry, osciloskopy, další vf zařízení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"9 kHz do 100 MHz","range":"od 20 pW do 20 nW","cmc":"1,8 % + 10 pW"},{"name":"100 MHz do 4 GHz","range":"od 20 pW do 20 nW","cmc":"2,1 % + 10 pW"},{"name":"4 GHz do 6 GHz","range":"od 20 pW do 20 nW","cmc":"2,5 % + 10 pW"}],"parameters_en":[{"name":"9 kHz to 100 MHz","range":"20 pW to 20 nW","cmc":"1,8 % + 10 pW"},{"name":"100 MHz to 4 GHz","range":"20 pW to 20 nW","cmc":"2,1 % + 10 pW"},{"name":"4 GHz to 6 GHz","range":"20 pW to 20 nW","cmc":"2,5 % + 10 pW"}],"parameters_zh":[{"name":"9 kHz 至 100 MHz","range":"20 pW 至 20 nW","cmc":"1,8 % + 10 pW"},{"name":"100 MHz 至 4 GHz","range":"20 pW 至 20 nW","cmc":"2,1 % + 10 pW"},{"name":"4 GHz 至 6 GHz","range":"20 pW 至 20 nW","cmc":"2,5 % + 10 pW"}],"parameters_cs":[{"name":"9 kHz až 100 MHz","range":"20 pW až 20 nW","cmc":"1,8 % + 10 pW"},{"name":"100 MHz až 4 GHz","range":"20 pW až 20 nW","cmc":"2,1 % + 10 pW"},{"name":"4 GHz až 6 GHz","range":"20 pW až 20 nW","cmc":"2,5 % + 10 pW"}],"technique":"Porównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku z tłumikiem","technique_en":"Comparison with a standard RF power meter on a symmetrical divider with an attenuator","technique_zh":"在带衰减器的对称功分器上与标准射频功率计比较","technique_cs":"Porovnání s etalonovým vf wattmetrem na symetrickém děliči s útlumovým článkem","techniques":["Porównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku z tłumikiem"],"techniques_en":["Comparison with a standard RF power meter on a symmetrical divider with an attenuator"],"techniques_zh":["在带衰减器的对称功分器上与标准射频功率计比较"],"techniques_cs":["Porovnání s etalonovým vf wattmetrem na symetrickém děliči s útlumovým článkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n9 kHz do 100 MHz od 20 pW do 20 nW CMC 1,8 % + 10 pW\n100 MHz do 4 GHz od 20 pW do 20 nW CMC 2,1 % + 10 pW\n4 GHz do 6 GHz od 20 pW do 20 nW CMC 2,5 % + 10 pW\nPorównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku z tłumikiem","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc w.cz. / watomierze w.cz., oscyloskopy, inne urządzenia w.cz. Wzorcowanie – wielkości elektryczne Porównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku z tłumikiem 9 kHz do 100 MHz od 20 pW do 20 nW CMC 1,8 % + 10 pW 100 MHz do 4 GHz od 20 pW do 20 nW CMC 2,1 % + 10 pW 4 GHz do 6 GHz od 20 pW do 20 nW CMC 2,5 % + 10 pW Vf výkon / vf wattmetry, osciloskopy, další vf zařízení Kalibrace – elektrické veličiny Porovnání s etalonovým vf wattmetrem na symetrickém děliči s útlumovým článkem 9 kHz až 100 MHz 20 pW až 20 nW CMC 1,8 % + 10 pW 100 MHz až 4 GHz 20 pW až 20 nW CMC 2,1 % + 10 pW 4 GHz až 6 GHz 20 pW až 20 nW CMC 2,5 % + 10 pW MK16 Moc w.cz. / watomierze w.cz., oscyloskopy, inne urzadzenia w.cz. Wzorcowanie – wielkosci elektryczne Porownanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku z tlumikiem 9 kHz do 100 MHz od 20 pW do 20 nW CMC 1,8 % + 10 pW 100 MHz do 4 GHz od 20 pW do 20 nW CMC 2,1 % + 10 pW 4 GHz do 6 GHz od 20 pW do 20 nW CMC 2,5 % + 10 pW Vf vykon / vf wattmetry, osciloskopy, dalsi vf zarizeni Kalibrace – elektricke veliciny Porovnani s etalonovym vf wattmetrem na symetrickem delici s utlumovym clankem 9 kHz az 100 MHz 20 pW az 20 nW CMC 1,8 % + 10 pW 100 MHz az 4 GHz 20 pW az 20 nW CMC 2,1 % + 10 pW 4 GHz az 6 GHz 20 pW az 20 nW CMC 2,5 % + 10 pW MK16","search_en":"RF power / RF power meters, oscilloscopes, other RF equipment Calibration – electrical quantities Comparison with a standard RF power meter on a symmetrical divider with an attenuator 9 kHz to 100 MHz 20 pW to 20 nW CMC 1,8 % + 10 pW 100 MHz to 4 GHz 20 pW to 20 nW CMC 2,1 % + 10 pW 4 GHz to 6 GHz 20 pW to 20 nW CMC 2,5 % + 10 pW MK16","search_zh":"射频功率 / 射频功率计、示波器、其他射频设备 校准 – 电学量 在带衰减器的对称功分器上与标准射频功率计比较 9 kHz 至 100 MHz 20 pW 至 20 nW CMC 1,8 % + 10 pW 100 MHz 至 4 GHz 20 pW 至 20 nW CMC 2,1 % + 10 pW 4 GHz 至 6 GHz 20 pW 至 20 nW CMC 2,5 % + 10 pW MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6da2f59bfa6e082eaa44830f","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"27","test_object":"Moc w.cz. / watomierze w.cz., oscyloskopy, inne urządzenia w.cz.","test_object_en":"RF power / RF power meters, oscilloscopes, other RF equipment","test_object_zh":"射频功率 / 射频功率计、示波器、其他射频设备","test_object_cs":"Vf výkon / vf wattmetry, osciloskopy, další vf zařízení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"9 kHz do 100 MHz","range":"od 20 nW do 5,5 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz do 4 GHz","range":"od 20 nW do 5,5 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz do 6 GHz","range":"od 20 nW do 5,5 mW","cmc":"2,0 % + 0,1 nW"}],"parameters_en":[{"name":"9 kHz to 100 MHz","range":"20 nW to 5,5 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz to 4 GHz","range":"20 nW to 5,5 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz to 6 GHz","range":"20 nW to 5,5 mW","cmc":"2,0 % + 0,1 nW"}],"parameters_zh":[{"name":"9 kHz 至 100 MHz","range":"20 nW 至 5,5 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz 至 4 GHz","range":"20 nW 至 5,5 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz 至 6 GHz","range":"20 nW 至 5,5 mW","cmc":"2,0 % + 0,1 nW"}],"parameters_cs":[{"name":"9 kHz až 100 MHz","range":"20 nW až 5,5 mW","cmc":"1,3 % + 0,1 nW"},{"name":"100 MHz až 4 GHz","range":"20 nW až 5,5 mW","cmc":"1,5 % + 0,1 nW"},{"name":"4 GHz až 6 GHz","range":"20 nW až 5,5 mW","cmc":"2,0 % + 0,1 nW"}],"technique":"Porównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku","technique_en":"Comparison with a standard RF power meter on a symmetrical divider","technique_zh":"在对称功分器上与标准射频功率计比较","technique_cs":"Porovnání s etalonovým vf wattmetrem na symetrickém děliči","techniques":["Porównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku"],"techniques_en":["Comparison with a standard RF power meter on a symmetrical divider"],"techniques_zh":["在对称功分器上与标准射频功率计比较"],"techniques_cs":["Porovnání s etalonovým vf wattmetrem na symetrickém děliči"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n9 kHz do 100 MHz od 20 nW do 5,5 mW CMC 1,3 % + 0,1 nW\n100 MHz do 4 GHz od 20 nW do 5,5 mW CMC 1,5 % + 0,1 nW\n4 GHz do 6 GHz od 20 nW do 5,5 mW CMC 2,0 % + 0,1 nW\nPorównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc w.cz. / watomierze w.cz., oscyloskopy, inne urządzenia w.cz. Wzorcowanie – wielkości elektryczne Porównanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku 9 kHz do 100 MHz od 20 nW do 5,5 mW CMC 1,3 % + 0,1 nW 100 MHz do 4 GHz od 20 nW do 5,5 mW CMC 1,5 % + 0,1 nW 4 GHz do 6 GHz od 20 nW do 5,5 mW CMC 2,0 % + 0,1 nW Vf výkon / vf wattmetry, osciloskopy, další vf zařízení Kalibrace – elektrické veličiny Porovnání s etalonovým vf wattmetrem na symetrickém děliči 9 kHz až 100 MHz 20 nW až 5,5 mW CMC 1,3 % + 0,1 nW 100 MHz až 4 GHz 20 nW až 5,5 mW CMC 1,5 % + 0,1 nW 4 GHz až 6 GHz 20 nW až 5,5 mW CMC 2,0 % + 0,1 nW MK16 Moc w.cz. / watomierze w.cz., oscyloskopy, inne urzadzenia w.cz. Wzorcowanie – wielkosci elektryczne Porownanie z wzorcowym watomierzem w.cz. na symetrycznym dzielniku 9 kHz do 100 MHz od 20 nW do 5,5 mW CMC 1,3 % + 0,1 nW 100 MHz do 4 GHz od 20 nW do 5,5 mW CMC 1,5 % + 0,1 nW 4 GHz do 6 GHz od 20 nW do 5,5 mW CMC 2,0 % + 0,1 nW Vf vykon / vf wattmetry, osciloskopy, dalsi vf zarizeni Kalibrace – elektricke veliciny Porovnani s etalonovym vf wattmetrem na symetrickem delici 9 kHz az 100 MHz 20 nW az 5,5 mW CMC 1,3 % + 0,1 nW 100 MHz az 4 GHz 20 nW az 5,5 mW CMC 1,5 % + 0,1 nW 4 GHz az 6 GHz 20 nW az 5,5 mW CMC 2,0 % + 0,1 nW MK16","search_en":"RF power / RF power meters, oscilloscopes, other RF equipment Calibration – electrical quantities Comparison with a standard RF power meter on a symmetrical divider 9 kHz to 100 MHz 20 nW to 5,5 mW CMC 1,3 % + 0,1 nW 100 MHz to 4 GHz 20 nW to 5,5 mW CMC 1,5 % + 0,1 nW 4 GHz to 6 GHz 20 nW to 5,5 mW CMC 2,0 % + 0,1 nW MK16","search_zh":"射频功率 / 射频功率计、示波器、其他射频设备 校准 – 电学量 在对称功分器上与标准射频功率计比较 9 kHz 至 100 MHz 20 nW 至 5,5 mW CMC 1,3 % + 0,1 nW 100 MHz 至 4 GHz 20 nW 至 5,5 mW CMC 1,5 % + 0,1 nW 4 GHz 至 6 GHz 20 nW 至 5,5 mW CMC 2,0 % + 0,1 nW MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8bb3ee8f636461a12f9cd932","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"27","test_object":"Moc w.cz. / watomierze w.cz., oscyloskopy, inne urządzenia w.cz.","test_object_en":"RF power / RF power meters, oscilloscopes, other RF equipment","test_object_zh":"射频功率 / 射频功率计、示波器、其他射频设备","test_object_cs":"Vf výkon / vf wattmetry, osciloskopy, další vf zařízení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"9 kHz do 100 MHz","range":"od 5,5 mW do 22,5 mW","cmc":"1,3 %"},{"name":"100 MHz do 300 MHz","range":"od 5,5 mW do 22,5 mW","cmc":"1,5 %"},{"name":"9 kHz do 100 MHz","range":"od 22,5 mW do 75,5 mW","cmc":"1,3 %"},{"name":"100 MHz do 250 MHz","range":"od 22,5 mW do 75,5 mW","cmc":"1,5 %"},{"name":"9 kHz do 50 MHz","range":"od 75,5 mW do 200 mW","cmc":"1,3 %"}],"parameters_en":[{"name":"9 kHz to 100 MHz","range":"5,5 mW to 22,5 mW","cmc":"1,3 %"},{"name":"100 MHz to 300 MHz","range":"5,5 mW to 22,5 mW","cmc":"1,5 %"},{"name":"9 kHz to 100 MHz","range":"22,5 mW to 75,5 mW","cmc":"1,3 %"},{"name":"100 MHz to 250 MHz","range":"22,5 mW to 75,5 mW","cmc":"1,5 %"},{"name":"9 kHz to 50 MHz","range":"75,5 mW to 200 mW","cmc":"1,3 %"}],"parameters_zh":[{"name":"9 kHz 至 100 MHz","range":"5,5 mW 至 22,5 mW","cmc":"1,3 %"},{"name":"100 MHz 至 300 MHz","range":"5,5 mW 至 22,5 mW","cmc":"1,5 %"},{"name":"9 kHz 至 100 MHz","range":"22,5 mW 至 75,5 mW","cmc":"1,3 %"},{"name":"100 MHz 至 250 MHz","range":"22,5 mW 至 75,5 mW","cmc":"1,5 %"},{"name":"9 kHz 至 50 MHz","range":"75,5 mW 至 200 mW","cmc":"1,3 %"}],"parameters_cs":[{"name":"9 kHz až 100 MHz","range":"5,5 mW až 22,5 mW","cmc":"1,3 %"},{"name":"100 MHz až 300 MHz","range":"5,5 mW až 22,5 mW","cmc":"1,5 %"},{"name":"9 kHz až 100 MHz","range":"22,5 mW až 75,5 mW","cmc":"1,3 %"},{"name":"100 MHz až 250 MHz","range":"22,5 mW až 75,5 mW","cmc":"1,5 %"},{"name":"9 kHz až 50 MHz","range":"75,5 mW až 200 mW","cmc":"1,3 %"}],"technique":"Porównanie z wzorcowym watomierzem w.cz. za pomocą generatora sygnałowego","technique_en":"Comparison with a standard RF power meter using a signal generator","technique_zh":"借助信号发生器与标准射频功率计比较","technique_cs":"Porovnání s etalonovým vf wattmetrem pomocí signálního generátoru","techniques":["Porównanie z wzorcowym watomierzem w.cz. za pomocą generatora sygnałowego"],"techniques_en":["Comparison with a standard RF power meter using a signal generator"],"techniques_zh":["借助信号发生器与标准射频功率计比较"],"techniques_cs":["Porovnání s etalonovým vf wattmetrem pomocí signálního generátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n9 kHz do 100 MHz od 5,5 mW do 22,5 mW CMC 1,3 %\n100 MHz do 300 MHz od 5,5 mW do 22,5 mW CMC 1,5 %\n9 kHz do 100 MHz od 22,5 mW do 75,5 mW CMC 1,3 %\n100 MHz do 250 MHz od 22,5 mW do 75,5 mW CMC 1,5 %\n9 kHz do 50 MHz od 75,5 mW do 200 mW CMC 1,3 %\nPorównanie z wzorcowym watomierzem w.cz. za pomocą generatora sygnałowego","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc w.cz. / watomierze w.cz., oscyloskopy, inne urządzenia w.cz. Wzorcowanie – wielkości elektryczne Porównanie z wzorcowym watomierzem w.cz. za pomocą generatora sygnałowego 9 kHz do 100 MHz od 5,5 mW do 22,5 mW CMC 1,3 % 100 MHz do 300 MHz od 5,5 mW do 22,5 mW CMC 1,5 % 9 kHz do 100 MHz od 22,5 mW do 75,5 mW CMC 1,3 % 100 MHz do 250 MHz od 22,5 mW do 75,5 mW CMC 1,5 % 9 kHz do 50 MHz od 75,5 mW do 200 mW CMC 1,3 % Vf výkon / vf wattmetry, osciloskopy, další vf zařízení Kalibrace – elektrické veličiny Porovnání s etalonovým vf wattmetrem pomocí signálního generátoru 9 kHz až 100 MHz 5,5 mW až 22,5 mW CMC 1,3 % 100 MHz až 300 MHz 5,5 mW až 22,5 mW CMC 1,5 % 9 kHz až 100 MHz 22,5 mW až 75,5 mW CMC 1,3 % 100 MHz až 250 MHz 22,5 mW až 75,5 mW CMC 1,5 % 9 kHz až 50 MHz 75,5 mW až 200 mW CMC 1,3 % MK16 Moc w.cz. / watomierze w.cz., oscyloskopy, inne urzadzenia w.cz. Wzorcowanie – wielkosci elektryczne Porownanie z wzorcowym watomierzem w.cz. za pomoca generatora sygnalowego 9 kHz do 100 MHz od 5,5 mW do 22,5 mW CMC 1,3 % 100 MHz do 300 MHz od 5,5 mW do 22,5 mW CMC 1,5 % 9 kHz do 100 MHz od 22,5 mW do 75,5 mW CMC 1,3 % 100 MHz do 250 MHz od 22,5 mW do 75,5 mW CMC 1,5 % 9 kHz do 50 MHz od 75,5 mW do 200 mW CMC 1,3 % Vf vykon / vf wattmetry, osciloskopy, dalsi vf zarizeni Kalibrace – elektricke veliciny Porovnani s etalonovym vf wattmetrem pomoci signalniho generatoru 9 kHz az 100 MHz 5,5 mW az 22,5 mW CMC 1,3 % 100 MHz az 300 MHz 5,5 mW az 22,5 mW CMC 1,5 % 9 kHz az 100 MHz 22,5 mW az 75,5 mW CMC 1,3 % 100 MHz az 250 MHz 22,5 mW az 75,5 mW CMC 1,5 % 9 kHz az 50 MHz 75,5 mW az 200 mW CMC 1,3 % MK16","search_en":"RF power / RF power meters, oscilloscopes, other RF equipment Calibration – electrical quantities Comparison with a standard RF power meter using a signal generator 9 kHz to 100 MHz 5,5 mW to 22,5 mW CMC 1,3 % 100 MHz to 300 MHz 5,5 mW to 22,5 mW CMC 1,5 % 9 kHz to 100 MHz 22,5 mW to 75,5 mW CMC 1,3 % 100 MHz to 250 MHz 22,5 mW to 75,5 mW CMC 1,5 % 9 kHz to 50 MHz 75,5 mW to 200 mW CMC 1,3 % MK16","search_zh":"射频功率 / 射频功率计、示波器、其他射频设备 校准 – 电学量 借助信号发生器与标准射频功率计比较 9 kHz 至 100 MHz 5,5 mW 至 22,5 mW CMC 1,3 % 100 MHz 至 300 MHz 5,5 mW 至 22,5 mW CMC 1,5 % 9 kHz 至 100 MHz 22,5 mW 至 75,5 mW CMC 1,3 % 100 MHz 至 250 MHz 22,5 mW 至 75,5 mW CMC 1,5 % 9 kHz 至 50 MHz 75,5 mW 至 200 mW CMC 1,3 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eeffd844dfe3c375bfccb3b0","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"28","test_object":"Moduł współczynnika odbicia 50 Ω / mierniki współczynnika odbicia (wektorowe i skalarne)","test_object_en":"Reflection coefficient magnitude 50 Ω / Reflection coefficient meters (vector and scalar)","test_object_zh":"50 Ω 反射系数模 / 反射系数测量仪（矢量和标量）","test_object_cs":"Modul činitele odrazu 50 Ω / Měřidla činitele odrazu (vektorová a skalární)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"złącze: N; 1 kHz do 2 GHz","range":"od 0,00 do 0,02","cmc":"0,006 (abs.)"},{"name":"złącze: N; 2 GHz do 3 GHz","range":"od 0,00 do 0,02","cmc":"0,008 (abs.)"},{"name":"złącze: N; 3 GHz do 6 GHz","range":"od 0,00 do 0,02","cmc":"0,010 (abs.)"},{"name":"złącze: N; 1 kHz do 2 GHz","range":"od 0,08 do 0,10","cmc":"0,006 (abs.)"},{"name":"złącze: N; 2 GHz do 3 GHz","range":"od 0,08 do 0,10","cmc":"0,008 (abs.)"},{"name":"złącze: N; 3 GHz do 6 GHz","range":"od 0,08 do 0,10","cmc":"0,010 (abs.)"},{"name":"złącze: N; 1 kHz do 2 GHz","range":"od 0,33 do 0,35","cmc":"0,007 (abs.)"},{"name":"złącze: N; 2 GHz do 6 GHz","range":"od 0,33 do 0,35","cmc":"0,010 (abs.)"}],"parameters_en":[{"name":"connector: N; 1 kHz to 2 GHz","range":"0,00 to 0,02","cmc":"0,006 (abs.)"},{"name":"connector: N; 2 GHz to 3 GHz","range":"0,00 to 0,02","cmc":"0,008 (abs.)"},{"name":"connector: N; 3 GHz to 6 GHz","range":"0,00 to 0,02","cmc":"0,010 (abs.)"},{"name":"connector: N; 1 kHz to 2 GHz","range":"0,08 to 0,10","cmc":"0,006 (abs.)"},{"name":"connector: N; 2 GHz to 3 GHz","range":"0,08 to 0,10","cmc":"0,008 (abs.)"},{"name":"connector: N; 3 GHz to 6 GHz","range":"0,08 to 0,10","cmc":"0,010 (abs.)"},{"name":"connector: N; 1 kHz to 2 GHz","range":"0,33 to 0,35","cmc":"0,007 (abs.)"},{"name":"connector: N; 2 GHz to 6 GHz","range":"0,33 to 0,35","cmc":"0,010 (abs.)"}],"parameters_zh":[{"name":"连接器：N；1 kHz 至 2 GHz","range":"0,00 至 0,02","cmc":"0,006 (abs.)"},{"name":"连接器：N；2 GHz 至 3 GHz","range":"0,00 至 0,02","cmc":"0,008 (abs.)"},{"name":"连接器：N；3 GHz 至 6 GHz","range":"0,00 至 0,02","cmc":"0,010 (abs.)"},{"name":"连接器：N；1 kHz 至 2 GHz","range":"0,08 至 0,10","cmc":"0,006 (abs.)"},{"name":"连接器：N；2 GHz 至 3 GHz","range":"0,08 至 0,10","cmc":"0,008 (abs.)"},{"name":"连接器：N；3 GHz 至 6 GHz","range":"0,08 至 0,10","cmc":"0,010 (abs.)"},{"name":"连接器：N；1 kHz 至 2 GHz","range":"0,33 至 0,35","cmc":"0,007 (abs.)"},{"name":"连接器：N；2 GHz 至 6 GHz","range":"0,33 至 0,35","cmc":"0,010 (abs.)"}],"parameters_cs":[{"name":"konektor: N; 1 kHz až 2 GHz","range":"0,00 až 0,02","cmc":"0,006 (abs.)"},{"name":"konektor: N; 2 GHz až 3 GHz","range":"0,00 až 0,02","cmc":"0,008 (abs.)"},{"name":"konektor: N; 3 GHz až 6 GHz","range":"0,00 až 0,02","cmc":"0,010 (abs.)"},{"name":"konektor: N; 1 kHz až 2 GHz","range":"0,08 až 0,10","cmc":"0,006 (abs.)"},{"name":"konektor: N; 2 GHz až 3 GHz","range":"0,08 až 0,10","cmc":"0,008 (abs.)"},{"name":"konektor: N; 3 GHz až 6 GHz","range":"0,08 až 0,10","cmc":"0,010 (abs.)"},{"name":"konektor: N; 1 kHz až 2 GHz","range":"0,33 až 0,35","cmc":"0,007 (abs.)"},{"name":"konektor: N; 2 GHz až 6 GHz","range":"0,33 až 0,35","cmc":"0,010 (abs.)"}],"technique":"Pomiar bezpośredni wzorców współczynnika odbicia","technique_en":"Direct measurement of reflection coefficient standards","technique_zh":"直接测量反射系数标准","technique_cs":"Přímé měření etalonů činitele odrazu","techniques":["Pomiar bezpośredni wzorców współczynnika odbicia"],"techniques_en":["Direct measurement of reflection coefficient standards"],"techniques_zh":["直接测量反射系数标准"],"techniques_cs":["Přímé měření etalonů činitele odrazu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nzłącze: N; 1 kHz do 2 GHz od 0,00 do 0,02 CMC 0,006 (abs.)\nzłącze: N; 2 GHz do 3 GHz od 0,00 do 0,02 CMC 0,008 (abs.)\nzłącze: N; 3 GHz do 6 GHz od 0,00 do 0,02 CMC 0,010 (abs.)\nzłącze: N; 1 kHz do 2 GHz od 0,08 do 0,10 CMC 0,006 (abs.)\nzłącze: N; 2 GHz do 3 GHz od 0,08 do 0,10 CMC 0,008 (abs.)\nzłącze: N; 3 GHz do 6 GHz od 0,08 do 0,10 CMC 0,010 (abs.)\nzłącze: N; 1 kHz do 2 GHz od 0,33 do 0,35 CMC 0,007 (abs.)\nzłącze: N; 2 GHz do 6 GHz od 0,33 do 0,35 CMC 0,010 (abs.)\nPomiar bezpośredni wzorców współczynnika odbicia","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":"Można użyć także innego rodzaju złącza, ale niepewność będzie wtedy większa.","note_en":"Another type of connector may also be used, but the uncertainty will be higher.","note_zh":"也可使用其他类型的连接器，但不确定度会更高。","note_cs":"Lze použít i jiný druh konektoru, ale hodnota nejistoty bude vyšší.","search_text":"Moduł współczynnika odbicia 50 Ω / mierniki współczynnika odbicia (wektorowe i skalarne) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorców współczynnika odbicia złącze: N; 1 kHz do 2 GHz od 0,00 do 0,02 CMC 0,006 (abs.) złącze: N; 2 GHz do 3 GHz od 0,00 do 0,02 CMC 0,008 (abs.) złącze: N; 3 GHz do 6 GHz od 0,00 do 0,02 CMC 0,010 (abs.) złącze: N; 1 kHz do 2 GHz od 0,08 do 0,10 CMC 0,006 (abs.) złącze: N; 2 GHz do 3 GHz od 0,08 do 0,10 CMC 0,008 (abs.) złącze: N; 3 GHz do 6 GHz od 0,08 do 0,10 CMC 0,010 (abs.) złącze: N; 1 kHz do 2 GHz od 0,33 do 0,35 CMC 0,007 (abs.) złącze: N; 2 GHz do 6 GHz od 0,33 do 0,35 CMC 0,010 (abs.) Modul činitele odrazu 50 Ω / Měřidla činitele odrazu (vektorová a skalární) Kalibrace – elektrické veličiny Přímé měření etalonů činitele odrazu konektor: N; 1 kHz až 2 GHz 0,00 až 0,02 CMC 0,006 (abs.) konektor: N; 2 GHz až 3 GHz 0,00 až 0,02 CMC 0,008 (abs.) konektor: N; 3 GHz až 6 GHz 0,00 až 0,02 CMC 0,010 (abs.) konektor: N; 1 kHz až 2 GHz 0,08 až 0,10 CMC 0,006 (abs.) konektor: N; 2 GHz až 3 GHz 0,08 až 0,10 CMC 0,008 (abs.) konektor: N; 3 GHz až 6 GHz 0,08 až 0,10 CMC 0,010 (abs.) konektor: N; 1 kHz až 2 GHz 0,33 až 0,35 CMC 0,007 (abs.) konektor: N; 2 GHz až 6 GHz 0,33 až 0,35 CMC 0,010 (abs.) MK16 Modul wspolczynnika odbicia 50 Ω / mierniki wspolczynnika odbicia (wektorowe i skalarne) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcow wspolczynnika odbicia zlacze: N; 1 kHz do 2 GHz od 0,00 do 0,02 CMC 0,006 (abs.) zlacze: N; 2 GHz do 3 GHz od 0,00 do 0,02 CMC 0,008 (abs.) zlacze: N; 3 GHz do 6 GHz od 0,00 do 0,02 CMC 0,010 (abs.) zlacze: N; 1 kHz do 2 GHz od 0,08 do 0,10 CMC 0,006 (abs.) zlacze: N; 2 GHz do 3 GHz od 0,08 do 0,10 CMC 0,008 (abs.) zlacze: N; 3 GHz do 6 GHz od 0,08 do 0,10 CMC 0,010 (abs.) zlacze: N; 1 kHz do 2 GHz od 0,33 do 0,35 CMC 0,007 (abs.) zlacze: N; 2 GHz do 6 GHz od 0,33 do 0,35 CMC 0,010 (abs.) Modul cinitele odrazu 50 Ω / Meridla cinitele odrazu (vektorova a skalarni) Kalibrace – elektricke veliciny Prime mereni etalonu cinitele odrazu konektor: N; 1 kHz az 2 GHz 0,00 az 0,02 CMC 0,006 (abs.) konektor: N; 2 GHz az 3 GHz 0,00 az 0,02 CMC 0,008 (abs.) konektor: N; 3 GHz az 6 GHz 0,00 az 0,02 CMC 0,010 (abs.) konektor: N; 1 kHz az 2 GHz 0,08 az 0,10 CMC 0,006 (abs.) konektor: N; 2 GHz az 3 GHz 0,08 az 0,10 CMC 0,008 (abs.) konektor: N; 3 GHz az 6 GHz 0,08 az 0,10 CMC 0,010 (abs.) konektor: N; 1 kHz az 2 GHz 0,33 az 0,35 CMC 0,007 (abs.) konektor: N; 2 GHz az 6 GHz 0,33 az 0,35 CMC 0,010 (abs.) MK16","search_en":"Reflection coefficient magnitude 50 Ω / Reflection coefficient meters (vector and scalar) Calibration – electrical quantities Direct measurement of reflection coefficient standards connector: N; 1 kHz to 2 GHz 0,00 to 0,02 CMC 0,006 (abs.) connector: N; 2 GHz to 3 GHz 0,00 to 0,02 CMC 0,008 (abs.) connector: N; 3 GHz to 6 GHz 0,00 to 0,02 CMC 0,010 (abs.) connector: N; 1 kHz to 2 GHz 0,08 to 0,10 CMC 0,006 (abs.) connector: N; 2 GHz to 3 GHz 0,08 to 0,10 CMC 0,008 (abs.) connector: N; 3 GHz to 6 GHz 0,08 to 0,10 CMC 0,010 (abs.) connector: N; 1 kHz to 2 GHz 0,33 to 0,35 CMC 0,007 (abs.) connector: N; 2 GHz to 6 GHz 0,33 to 0,35 CMC 0,010 (abs.) MK16","search_zh":"50 Ω 反射系数模 / 反射系数测量仪（矢量和标量） 校准 – 电学量 直接测量反射系数标准 连接器：N；1 kHz 至 2 GHz 0,00 至 0,02 CMC 0,006 (abs.) 连接器：N；2 GHz 至 3 GHz 0,00 至 0,02 CMC 0,008 (abs.) 连接器：N；3 GHz 至 6 GHz 0,00 至 0,02 CMC 0,010 (abs.) 连接器：N；1 kHz 至 2 GHz 0,08 至 0,10 CMC 0,006 (abs.) 连接器：N；2 GHz 至 3 GHz 0,08 至 0,10 CMC 0,008 (abs.) 连接器：N；3 GHz 至 6 GHz 0,08 至 0,10 CMC 0,010 (abs.) 连接器：N；1 kHz 至 2 GHz 0,33 至 0,35 CMC 0,007 (abs.) 连接器：N；2 GHz 至 6 GHz 0,33 至 0,35 CMC 0,010 (abs.) MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49d2658acd772baef7da75ed","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"28","test_object":"Moduł współczynnika odbicia 50 Ω / watomierze w.cz., oscyloskopy, tłumiki, wzmacniacze, inne urządzenia w.cz.","test_object_en":"Reflection coefficient magnitude 50 Ω / RF power meters, oscilloscopes, attenuators, amplifiers, other RF equipment","test_object_zh":"50 Ω 反射系数模 / 射频功率计、示波器、衰减器、放大器、其他射频设备","test_object_cs":"Modul činitele odrazu 50 Ω / vf wattmetry, osciloskopy, útlumové články, zesilovače, další vf zařízení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,3 MHz do 1 MHz","range":"od 0 do 1","cmc":"0,016 + 0,03·r² (abs.)"},{"name":"1 MHz do 2 GHz","range":"od 0 do 1","cmc":"0,008 + 0,03·r² (abs.)"},{"name":"2 GHz do 3 GHz","range":"od 0 do 1","cmc":"0,010 + 0,06·r² (abs.)"}],"parameters_en":[{"name":"0,3 MHz to 1 MHz","range":"0 to 1","cmc":"0,016 + 0,03·r² (abs.)"},{"name":"1 MHz to 2 GHz","range":"0 to 1","cmc":"0,008 + 0,03·r² (abs.)"},{"name":"2 GHz to 3 GHz","range":"0 to 1","cmc":"0,010 + 0,06·r² (abs.)"}],"parameters_zh":[{"name":"0,3 MHz 至 1 MHz","range":"0 至 1","cmc":"0,016 + 0,03·r² (abs.)"},{"name":"1 MHz 至 2 GHz","range":"0 至 1","cmc":"0,008 + 0,03·r² (abs.)"},{"name":"2 GHz 至 3 GHz","range":"0 至 1","cmc":"0,010 + 0,06·r² (abs.)"}],"parameters_cs":[{"name":"0,3 MHz až 1 MHz","range":"0 až 1","cmc":"0,016 + 0,03·r² (abs.)"},{"name":"1 MHz až 2 GHz","range":"0 až 1","cmc":"0,008 + 0,03·r² (abs.)"},{"name":"2 GHz až 3 GHz","range":"0 až 1","cmc":"0,010 + 0,06·r² (abs.)"}],"technique":"Pomiar za pomocą wzorcowego sprzęgacza kierunkowego (r — moduł współczynnika odbicia)","technique_en":"Measurement using a standard directional coupler (r is the reflection coefficient magnitude)","technique_zh":"用标准定向耦合器测量（r 为反射系数模）","technique_cs":"Měření pomocí etalonové směrové odbočnice (r je modul činitele odrazu)","techniques":["Pomiar za pomocą wzorcowego sprzęgacza kierunkowego (r — moduł współczynnika odbicia)"],"techniques_en":["Measurement using a standard directional coupler (r is the reflection coefficient magnitude)"],"techniques_zh":["用标准定向耦合器测量（r 为反射系数模）"],"techniques_cs":["Měření pomocí etalonové směrové odbočnice (r je modul činitele odrazu)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,3 MHz do 1 MHz od 0 do 1 CMC 0,016 + 0,03·r² (abs.)\n1 MHz do 2 GHz od 0 do 1 CMC 0,008 + 0,03·r² (abs.)\n2 GHz do 3 GHz od 0 do 1 CMC 0,010 + 0,06·r² (abs.)\nPomiar za pomocą wzorcowego sprzęgacza kierunkowego (r — moduł współczynnika odbicia)","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł współczynnika odbicia 50 Ω / watomierze w.cz., oscyloskopy, tłumiki, wzmacniacze, inne urządzenia w.cz. Wzorcowanie – wielkości elektryczne Pomiar za pomocą wzorcowego sprzęgacza kierunkowego (r — moduł współczynnika odbicia) 0,3 MHz do 1 MHz od 0 do 1 CMC 0,016 + 0,03·r² (abs.) 1 MHz do 2 GHz od 0 do 1 CMC 0,008 + 0,03·r² (abs.) 2 GHz do 3 GHz od 0 do 1 CMC 0,010 + 0,06·r² (abs.) Modul činitele odrazu 50 Ω / vf wattmetry, osciloskopy, útlumové články, zesilovače, další vf zařízení Kalibrace – elektrické veličiny Měření pomocí etalonové směrové odbočnice (r je modul činitele odrazu) 0,3 MHz až 1 MHz 0 až 1 CMC 0,016 + 0,03·r² (abs.) 1 MHz až 2 GHz 0 až 1 CMC 0,008 + 0,03·r² (abs.) 2 GHz až 3 GHz 0 až 1 CMC 0,010 + 0,06·r² (abs.) MK16 Modul wspolczynnika odbicia 50 Ω / watomierze w.cz., oscyloskopy, tlumiki, wzmacniacze, inne urzadzenia w.cz. Wzorcowanie – wielkosci elektryczne Pomiar za pomoca wzorcowego sprzegacza kierunkowego (r — modul wspolczynnika odbicia) 0,3 MHz do 1 MHz od 0 do 1 CMC 0,016 + 0,03·r² (abs.) 1 MHz do 2 GHz od 0 do 1 CMC 0,008 + 0,03·r² (abs.) 2 GHz do 3 GHz od 0 do 1 CMC 0,010 + 0,06·r² (abs.) Modul cinitele odrazu 50 Ω / vf wattmetry, osciloskopy, utlumove clanky, zesilovace, dalsi vf zarizeni Kalibrace – elektricke veliciny Mereni pomoci etalonove smerove odbocnice (r je modul cinitele odrazu) 0,3 MHz az 1 MHz 0 az 1 CMC 0,016 + 0,03·r² (abs.) 1 MHz az 2 GHz 0 az 1 CMC 0,008 + 0,03·r² (abs.) 2 GHz az 3 GHz 0 az 1 CMC 0,010 + 0,06·r² (abs.) MK16","search_en":"Reflection coefficient magnitude 50 Ω / RF power meters, oscilloscopes, attenuators, amplifiers, other RF equipment Calibration – electrical quantities Measurement using a standard directional coupler (r is the reflection coefficient magnitude) 0,3 MHz to 1 MHz 0 to 1 CMC 0,016 + 0,03·r² (abs.) 1 MHz to 2 GHz 0 to 1 CMC 0,008 + 0,03·r² (abs.) 2 GHz to 3 GHz 0 to 1 CMC 0,010 + 0,06·r² (abs.) MK16","search_zh":"50 Ω 反射系数模 / 射频功率计、示波器、衰减器、放大器、其他射频设备 校准 – 电学量 用标准定向耦合器测量（r 为反射系数模） 0,3 MHz 至 1 MHz 0 至 1 CMC 0,016 + 0,03·r² (abs.) 1 MHz 至 2 GHz 0 至 1 CMC 0,008 + 0,03·r² (abs.) 2 GHz 至 3 GHz 0 至 1 CMC 0,010 + 0,06·r² (abs.) MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b9b3d289269b0bd6dd25de2","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"28","test_object":"Moduł współczynnika odbicia 50 Ω / watomierze w.cz., oscyloskopy, tłumiki, wzmacniacze, inne urządzenia w.cz.","test_object_en":"Reflection coefficient magnitude 50 Ω / RF power meters, oscilloscopes, attenuators, amplifiers, other RF equipment","test_object_zh":"50 Ω 反射系数模 / 射频功率计、示波器、衰减器、放大器、其他射频设备","test_object_cs":"Modul činitele odrazu 50 Ω / vf wattmetry, osciloskopy, útlumové články, zesilovače, další vf zařízení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"3 GHz do 4 GHz","range":"od 0 do 1","cmc":"0,015 + 0,06·r² (abs.)"},{"name":"4 GHz do 6 GHz","range":"od 0 do 1","cmc":"0,020 + 0,06·r² (abs.)"}],"parameters_en":[{"name":"3 GHz to 4 GHz","range":"0 to 1","cmc":"0,015 + 0,06·r² (abs.)"},{"name":"4 GHz to 6 GHz","range":"0 to 1","cmc":"0,020 + 0,06·r² (abs.)"}],"parameters_zh":[{"name":"3 GHz 至 4 GHz","range":"0 至 1","cmc":"0,015 + 0,06·r² (abs.)"},{"name":"4 GHz 至 6 GHz","range":"0 至 1","cmc":"0,020 + 0,06·r² (abs.)"}],"parameters_cs":[{"name":"3 GHz až 4 GHz","range":"0 až 1","cmc":"0,015 + 0,06·r² (abs.)"},{"name":"4 GHz až 6 GHz","range":"0 až 1","cmc":"0,020 + 0,06·r² (abs.)"}],"technique":"Pomiar wzorcowym wektorowym analizatorem obwodów","technique_en":"Measurement by a standard vector network analyser","technique_zh":"用标准矢量网络分析仪测量","technique_cs":"Měření etalonovým vektorovým analyzátorem obvodů","techniques":["Pomiar wzorcowym wektorowym analizatorem obwodów"],"techniques_en":["Measurement by a standard vector network analyser"],"techniques_zh":["用标准矢量网络分析仪测量"],"techniques_cs":["Měření etalonovým vektorovým analyzátorem obvodů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n3 GHz do 4 GHz od 0 do 1 CMC 0,015 + 0,06·r² (abs.)\n4 GHz do 6 GHz od 0 do 1 CMC 0,020 + 0,06·r² (abs.)\nPomiar wzorcowym wektorowym analizatorem obwodów","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł współczynnika odbicia 50 Ω / watomierze w.cz., oscyloskopy, tłumiki, wzmacniacze, inne urządzenia w.cz. Wzorcowanie – wielkości elektryczne Pomiar wzorcowym wektorowym analizatorem obwodów 3 GHz do 4 GHz od 0 do 1 CMC 0,015 + 0,06·r² (abs.) 4 GHz do 6 GHz od 0 do 1 CMC 0,020 + 0,06·r² (abs.) Modul činitele odrazu 50 Ω / vf wattmetry, osciloskopy, útlumové články, zesilovače, další vf zařízení Kalibrace – elektrické veličiny Měření etalonovým vektorovým analyzátorem obvodů 3 GHz až 4 GHz 0 až 1 CMC 0,015 + 0,06·r² (abs.) 4 GHz až 6 GHz 0 až 1 CMC 0,020 + 0,06·r² (abs.) MK16 Modul wspolczynnika odbicia 50 Ω / watomierze w.cz., oscyloskopy, tlumiki, wzmacniacze, inne urzadzenia w.cz. Wzorcowanie – wielkosci elektryczne Pomiar wzorcowym wektorowym analizatorem obwodow 3 GHz do 4 GHz od 0 do 1 CMC 0,015 + 0,06·r² (abs.) 4 GHz do 6 GHz od 0 do 1 CMC 0,020 + 0,06·r² (abs.) Modul cinitele odrazu 50 Ω / vf wattmetry, osciloskopy, utlumove clanky, zesilovace, dalsi vf zarizeni Kalibrace – elektricke veliciny Mereni etalonovym vektorovym analyzatorem obvodu 3 GHz az 4 GHz 0 az 1 CMC 0,015 + 0,06·r² (abs.) 4 GHz az 6 GHz 0 az 1 CMC 0,020 + 0,06·r² (abs.) MK16","search_en":"Reflection coefficient magnitude 50 Ω / RF power meters, oscilloscopes, attenuators, amplifiers, other RF equipment Calibration – electrical quantities Measurement by a standard vector network analyser 3 GHz to 4 GHz 0 to 1 CMC 0,015 + 0,06·r² (abs.) 4 GHz to 6 GHz 0 to 1 CMC 0,020 + 0,06·r² (abs.) MK16","search_zh":"50 Ω 反射系数模 / 射频功率计、示波器、衰减器、放大器、其他射频设备 校准 – 电学量 用标准矢量网络分析仪测量 3 GHz 至 4 GHz 0 至 1 CMC 0,015 + 0,06·r² (abs.) 4 GHz 至 6 GHz 0 至 1 CMC 0,020 + 0,06·r² (abs.) MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c8ad548eb0c9d52534f6604","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"29","test_object":"Kąt fazowy współczynnika odbicia 50 Ω / wektorowe analizatory obwodów","test_object_en":"Reflection coefficient phase angle 50 Ω / Vector network analysers","test_object_zh":"50 Ω 反射系数相角 / 矢量网络分析仪","test_object_cs":"Fázový úhel činitele odrazu 50 Ω / Vektorové analyzátory obvodů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"moduł 0,092, złącze: N(f); 1 kHz do 1,1 GHz","range":"od 90° do 180°","cmc":"5,5°"},{"name":"moduł 0,092, złącze: N(f); 1,1 GHz do 2,2 GHz","range":"od 0° do 90°","cmc":"5,5°"},{"name":"moduł 0,092, złącze: N(f); 2,2 GHz do 3,3 GHz","range":"od -90° do 0°","cmc":"5,5°"},{"name":"moduł 0,092, złącze: N(f); 3,3 GHz do 4,4 GHz","range":"od -180 do -90°","cmc":"6,0°"},{"name":"moduł 0,092, złącze: N(f); 4,4 GHz do 5,4 GHz","range":"od 90° do 180°","cmc":"6,0°"},{"name":"moduł 0,092, złącze: N(f); 5,4 GHz do 6,0 GHz","range":"od 40° do 90°","cmc":"6,0°"},{"name":"moduł 0,338, złącze: N(f); 1 kHz do 1,1 GHz","range":"od 90° do 180°","cmc":"1,6°"},{"name":"moduł 0,338, złącze: N(f); 1,1 GHz do 2,2 GHz","range":"od 0° do 90°","cmc":"1,8°"},{"name":"moduł 0,338, złącze: N(f); 2,2 GHz do 3,4 GHz","range":"od -90° do 0°","cmc":"1,8°"},{"name":"moduł 0,338, złącze: N(f); 3,4 GHz do 4,4 GHz","range":"od -180 do -90°","cmc":"2,0°"},{"name":"moduł 0,338, złącze: N(f); 4,4 GHz do 5,5 GHz","range":"od 90° do 180°","cmc":"2,0°"},{"name":"moduł 0,338, złącze: N(f); 5,5 GHz do 6,0 GHz","range":"od 50° do 90°","cmc":"2,0°"}],"parameters_en":[{"name":"magnitude 0,092, connector: N(f); 1 kHz to 1,1 GHz","range":"90° to 180°","cmc":"5,5°"},{"name":"magnitude 0,092, connector: N(f); 1,1 GHz to 2,2 GHz","range":"0° to 90°","cmc":"5,5°"},{"name":"magnitude 0,092, connector: N(f); 2,2 GHz to 3,3 GHz","range":"-90° to 0°","cmc":"5,5°"},{"name":"magnitude 0,092, connector: N(f); 3,3 GHz to 4,4 GHz","range":"-180 to -90°","cmc":"6,0°"},{"name":"magnitude 0,092, connector: N(f); 4,4 GHz to 5,4 GHz","range":"90° to 180°","cmc":"6,0°"},{"name":"magnitude 0,092, connector: N(f); 5,4 GHz to 6,0 GHz","range":"40° to 90°","cmc":"6,0°"},{"name":"magnitude 0,338, connector: N(f); 1 kHz to 1,1 GHz","range":"90° to 180°","cmc":"1,6°"},{"name":"magnitude 0,338, connector: N(f); 1,1 GHz to 2,2 GHz","range":"0° to 90°","cmc":"1,8°"},{"name":"magnitude 0,338, connector: N(f); 2,2 GHz to 3,4 GHz","range":"-90° to 0°","cmc":"1,8°"},{"name":"magnitude 0,338, connector: N(f); 3,4 GHz to 4,4 GHz","range":"-180 to -90°","cmc":"2,0°"},{"name":"magnitude 0,338, connector: N(f); 4,4 GHz to 5,5 GHz","range":"90° to 180°","cmc":"2,0°"},{"name":"magnitude 0,338, connector: N(f); 5,5 GHz to 6,0 GHz","range":"50° to 90°","cmc":"2,0°"}],"parameters_zh":[{"name":"模 0,092，连接器：N(f)；1 kHz 至 1,1 GHz","range":"90° 至 180°","cmc":"5,5°"},{"name":"模 0,092，连接器：N(f)；1,1 GHz 至 2,2 GHz","range":"0° 至 90°","cmc":"5,5°"},{"name":"模 0,092，连接器：N(f)；2,2 GHz 至 3,3 GHz","range":"-90° 至 0°","cmc":"5,5°"},{"name":"模 0,092，连接器：N(f)；3,3 GHz 至 4,4 GHz","range":"-180 至 -90°","cmc":"6,0°"},{"name":"模 0,092，连接器：N(f)；4,4 GHz 至 5,4 GHz","range":"90° 至 180°","cmc":"6,0°"},{"name":"模 0,092，连接器：N(f)；5,4 GHz 至 6,0 GHz","range":"40° 至 90°","cmc":"6,0°"},{"name":"模 0,338，连接器：N(f)；1 kHz 至 1,1 GHz","range":"90° 至 180°","cmc":"1,6°"},{"name":"模 0,338，连接器：N(f)；1,1 GHz 至 2,2 GHz","range":"0° 至 90°","cmc":"1,8°"},{"name":"模 0,338，连接器：N(f)；2,2 GHz 至 3,4 GHz","range":"-90° 至 0°","cmc":"1,8°"},{"name":"模 0,338，连接器：N(f)；3,4 GHz 至 4,4 GHz","range":"-180 至 -90°","cmc":"2,0°"},{"name":"模 0,338，连接器：N(f)；4,4 GHz 至 5,5 GHz","range":"90° 至 180°","cmc":"2,0°"},{"name":"模 0,338，连接器：N(f)；5,5 GHz 至 6,0 GHz","range":"50° 至 90°","cmc":"2,0°"}],"parameters_cs":[{"name":"modul 0,092, konektor: N(f); 1 kHz až 1,1 GHz","range":"90° až 180°","cmc":"5,5°"},{"name":"modul 0,092, konektor: N(f); 1,1 GHz až 2,2 GHz","range":"0° až 90°","cmc":"5,5°"},{"name":"modul 0,092, konektor: N(f); 2,2 GHz až 3,3 GHz","range":"-90° až 0°","cmc":"5,5°"},{"name":"modul 0,092, konektor: N(f); 3,3 GHz až 4,4 GHz","range":"-180 až -90°","cmc":"6,0°"},{"name":"modul 0,092, konektor: N(f); 4,4 GHz až 5,4 GHz","range":"90° až 180°","cmc":"6,0°"},{"name":"modul 0,092, konektor: N(f); 5,4 GHz až 6,0 GHz","range":"40° až 90°","cmc":"6,0°"},{"name":"modul 0,338, konektor: N(f); 1 kHz až 1,1 GHz","range":"90° až 180°","cmc":"1,6°"},{"name":"modul 0,338, konektor: N(f); 1,1 GHz až 2,2 GHz","range":"0° až 90°","cmc":"1,8°"},{"name":"modul 0,338, konektor: N(f); 2,2 GHz až 3,4 GHz","range":"-90° až 0°","cmc":"1,8°"},{"name":"modul 0,338, konektor: N(f); 3,4 GHz až 4,4 GHz","range":"-180 až -90°","cmc":"2,0°"},{"name":"modul 0,338, konektor: N(f); 4,4 GHz až 5,5 GHz","range":"90° až 180°","cmc":"2,0°"},{"name":"modul 0,338, konektor: N(f); 5,5 GHz až 6,0 GHz","range":"50° až 90°","cmc":"2,0°"}],"technique":"Pomiar bezpośredni wzorców współczynnika odbicia","technique_en":"Direct measurement of reflection coefficient standards","technique_zh":"直接测量反射系数标准","technique_cs":"Přímé měření etalonů činitele odrazu","techniques":["Pomiar bezpośredni wzorców współczynnika odbicia"],"techniques_en":["Direct measurement of reflection coefficient standards"],"techniques_zh":["直接测量反射系数标准"],"techniques_cs":["Přímé měření etalonů činitele odrazu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nmoduł 0,092, złącze: N(f); 1 kHz do 1,1 GHz od 90° do 180° CMC 5,5°\nmoduł 0,092, złącze: N(f); 1,1 GHz do 2,2 GHz od 0° do 90° CMC 5,5°\nmoduł 0,092, złącze: N(f); 2,2 GHz do 3,3 GHz od -90° do 0° CMC 5,5°\nmoduł 0,092, złącze: N(f); 3,3 GHz do 4,4 GHz od -180 do -90° CMC 6,0°\nmoduł 0,092, złącze: N(f); 4,4 GHz do 5,4 GHz od 90° do 180° CMC 6,0°\nmoduł 0,092, złącze: N(f); 5,4 GHz do 6,0 GHz od 40° do 90° CMC 6,0°\nmoduł 0,338, złącze: N(f); 1 kHz do 1,1 GHz od 90° do 180° CMC 1,6°\nmoduł 0,338, złącze: N(f); 1,1 GHz do 2,2 GHz od 0° do 90° CMC 1,8°\nmoduł 0,338, złącze: N(f); 2,2 GHz do 3,4 GHz od -90° do 0° CMC 1,8°\nmoduł 0,338, złącze: N(f); 3,4 GHz do 4,4 GHz od -180 do -90° CMC 2,0°\nmoduł 0,338, złącze: N(f); 4,4 GHz do 5,5 GHz od 90° do 180° CMC 2,0°\nmoduł 0,338, złącze: N(f); 5,5 GHz do 6,0 GHz od 50° do 90° CMC 2,0°\nPomiar bezpośredni wzorców współczynnika odbicia","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":"Złącze na obiekcie wzorcowania.","note_en":"Connector on the item being calibrated.","note_zh":"被校准对象上的连接器。","note_cs":"Konektor na předmětu kalibrace.","search_text":"Kąt fazowy współczynnika odbicia 50 Ω / wektorowe analizatory obwodów Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorców współczynnika odbicia moduł 0,092, złącze: N(f); 1 kHz do 1,1 GHz od 90° do 180° CMC 5,5° moduł 0,092, złącze: N(f); 1,1 GHz do 2,2 GHz od 0° do 90° CMC 5,5° moduł 0,092, złącze: N(f); 2,2 GHz do 3,3 GHz od -90° do 0° CMC 5,5° moduł 0,092, złącze: N(f); 3,3 GHz do 4,4 GHz od -180 do -90° CMC 6,0° moduł 0,092, złącze: N(f); 4,4 GHz do 5,4 GHz od 90° do 180° CMC 6,0° moduł 0,092, złącze: N(f); 5,4 GHz do 6,0 GHz od 40° do 90° CMC 6,0° moduł 0,338, złącze: N(f); 1 kHz do 1,1 GHz od 90° do 180° CMC 1,6° moduł 0,338, złącze: N(f); 1,1 GHz do 2,2 GHz od 0° do 90° CMC 1,8° moduł 0,338, złącze: N(f); 2,2 GHz do 3,4 GHz od -90° do 0° CMC 1,8° moduł 0,338, złącze: N(f); 3,4 GHz do 4,4 GHz od -180 do -90° CMC 2,0° moduł 0,338, złącze: N(f); 4,4 GHz do 5,5 GHz od 90° do 180° CMC 2,0° moduł 0,338, złącze: N(f); 5,5 GHz do 6,0 GHz od 50° do 90° CMC 2,0° Fázový úhel činitele odrazu 50 Ω / Vektorové analyzátory obvodů Kalibrace – elektrické veličiny Přímé měření etalonů činitele odrazu modul 0,092, konektor: N(f); 1 kHz až 1,1 GHz 90° až 180° CMC 5,5° modul 0,092, konektor: N(f); 1,1 GHz až 2,2 GHz 0° až 90° CMC 5,5° modul 0,092, konektor: N(f); 2,2 GHz až 3,3 GHz -90° až 0° CMC 5,5° modul 0,092, konektor: N(f); 3,3 GHz až 4,4 GHz -180 až -90° CMC 6,0° modul 0,092, konektor: N(f); 4,4 GHz až 5,4 GHz 90° až 180° CMC 6,0° modul 0,092, konektor: N(f); 5,4 GHz až 6,0 GHz 40° až 90° CMC 6,0° modul 0,338, konektor: N(f); 1 kHz až 1,1 GHz 90° až 180° CMC 1,6° modul 0,338, konektor: N(f); 1,1 GHz až 2,2 GHz 0° až 90° CMC 1,8° modul 0,338, konektor: N(f); 2,2 GHz až 3,4 GHz -90° až 0° CMC 1,8° modul 0,338, konektor: N(f); 3,4 GHz až 4,4 GHz -180 až -90° CMC 2,0° modul 0,338, konektor: N(f); 4,4 GHz až 5,5 GHz 90° až 180° CMC 2,0° modul 0,338, konektor: N(f); 5,5 GHz až 6,0 GHz 50° až 90° CMC 2,0° MK16 Kat fazowy wspolczynnika odbicia 50 Ω / wektorowe analizatory obwodow Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcow wspolczynnika odbicia modul 0,092, zlacze: N(f); 1 kHz do 1,1 GHz od 90° do 180° CMC 5,5° modul 0,092, zlacze: N(f); 1,1 GHz do 2,2 GHz od 0° do 90° CMC 5,5° modul 0,092, zlacze: N(f); 2,2 GHz do 3,3 GHz od -90° do 0° CMC 5,5° modul 0,092, zlacze: N(f); 3,3 GHz do 4,4 GHz od -180 do -90° CMC 6,0° modul 0,092, zlacze: N(f); 4,4 GHz do 5,4 GHz od 90° do 180° CMC 6,0° modul 0,092, zlacze: N(f); 5,4 GHz do 6,0 GHz od 40° do 90° CMC 6,0° modul 0,338, zlacze: N(f); 1 kHz do 1,1 GHz od 90° do 180° CMC 1,6° modul 0,338, zlacze: N(f); 1,1 GHz do 2,2 GHz od 0° do 90° CMC 1,8° modul 0,338, zlacze: N(f); 2,2 GHz do 3,4 GHz od -90° do 0° CMC 1,8° modul 0,338, zlacze: N(f); 3,4 GHz do 4,4 GHz od -180 do -90° CMC 2,0° modul 0,338, zlacze: N(f); 4,4 GHz do 5,5 GHz od 90° do 180° CMC 2,0° modul 0,338, zlacze: N(f); 5,5 GHz do 6,0 GHz od 50° do 90° CMC 2,0° Fazovy uhel cinitele odrazu 50 Ω / Vektorove analyzatory obvodu Kalibrace – elektricke veliciny Prime mereni etalonu cinitele odrazu modul 0,092, konektor: N(f); 1 kHz az 1,1 GHz 90° az 180° CMC 5,5° modul 0,092, konektor: N(f); 1,1 GHz az 2,2 GHz 0° az 90° CMC 5,5° modul 0,092, konektor: N(f); 2,2 GHz az 3,3 GHz -90° az 0° CMC 5,5° modul 0,092, konektor: N(f); 3,3 GHz az 4,4 GHz -180 az -90° CMC 6,0° modul 0,092, konektor: N(f); 4,4 GHz az 5,4 GHz 90° az 180° CMC 6,0° modul 0,092, konektor: N(f); 5,4 GHz az 6,0 GHz 40° az 90° CMC 6,0° modul 0,338, konektor: N(f); 1 kHz az 1,1 GHz 90° az 180° CMC 1,6° modul 0,338, konektor: N(f); 1,1 GHz az 2,2 GHz 0° az 90° CMC 1,8° modul 0,338, konektor: N(f); 2,2 GHz az 3,4 GHz -90° az 0° CMC 1,8° modul 0,338, konektor: N(f); 3,4 GHz az 4,4 GHz -180 az -90° CMC 2,0° modul 0,338, konektor: N(f); 4,4 GHz az 5,5 GHz 90° az 180° CMC 2,0° modul 0,338, konektor: N(f); 5,5 GHz az 6,0 GHz 50° az 90° CMC 2,0° MK16","search_en":"Reflection coefficient phase angle 50 Ω / Vector network analysers Calibration – electrical quantities Direct measurement of reflection coefficient standards magnitude 0,092, connector: N(f); 1 kHz to 1,1 GHz 90° to 180° CMC 5,5° magnitude 0,092, connector: N(f); 1,1 GHz to 2,2 GHz 0° to 90° CMC 5,5° magnitude 0,092, connector: N(f); 2,2 GHz to 3,3 GHz -90° to 0° CMC 5,5° magnitude 0,092, connector: N(f); 3,3 GHz to 4,4 GHz -180 to -90° CMC 6,0° magnitude 0,092, connector: N(f); 4,4 GHz to 5,4 GHz 90° to 180° CMC 6,0° magnitude 0,092, connector: N(f); 5,4 GHz to 6,0 GHz 40° to 90° CMC 6,0° magnitude 0,338, connector: N(f); 1 kHz to 1,1 GHz 90° to 180° CMC 1,6° magnitude 0,338, connector: N(f); 1,1 GHz to 2,2 GHz 0° to 90° CMC 1,8° magnitude 0,338, connector: N(f); 2,2 GHz to 3,4 GHz -90° to 0° CMC 1,8° magnitude 0,338, connector: N(f); 3,4 GHz to 4,4 GHz -180 to -90° CMC 2,0° magnitude 0,338, connector: N(f); 4,4 GHz to 5,5 GHz 90° to 180° CMC 2,0° magnitude 0,338, connector: N(f); 5,5 GHz to 6,0 GHz 50° to 90° CMC 2,0° MK16","search_zh":"50 Ω 反射系数相角 / 矢量网络分析仪 校准 – 电学量 直接测量反射系数标准 模 0,092，连接器：N(f)；1 kHz 至 1,1 GHz 90° 至 180° CMC 5,5° 模 0,092，连接器：N(f)；1,1 GHz 至 2,2 GHz 0° 至 90° CMC 5,5° 模 0,092，连接器：N(f)；2,2 GHz 至 3,3 GHz -90° 至 0° CMC 5,5° 模 0,092，连接器：N(f)；3,3 GHz 至 4,4 GHz -180 至 -90° CMC 6,0° 模 0,092，连接器：N(f)；4,4 GHz 至 5,4 GHz 90° 至 180° CMC 6,0° 模 0,092，连接器：N(f)；5,4 GHz 至 6,0 GHz 40° 至 90° CMC 6,0° 模 0,338，连接器：N(f)；1 kHz 至 1,1 GHz 90° 至 180° CMC 1,6° 模 0,338，连接器：N(f)；1,1 GHz 至 2,2 GHz 0° 至 90° CMC 1,8° 模 0,338，连接器：N(f)；2,2 GHz 至 3,4 GHz -90° 至 0° CMC 1,8° 模 0,338，连接器：N(f)；3,4 GHz 至 4,4 GHz -180 至 -90° CMC 2,0° 模 0,338，连接器：N(f)；4,4 GHz 至 5,5 GHz 90° 至 180° CMC 2,0° 模 0,338，连接器：N(f)；5,5 GHz 至 6,0 GHz 50° 至 90° CMC 2,0° MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"92cbe0e13cb131d432c563be","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"30","test_object":"Stosunek napięć / sztuczne sieci, człony sprzęgające","test_object_en":"Voltage ratio / Artificial networks, coupling networks","test_object_zh":"电压比 / 人工电源网络、耦合网络","test_object_cs":"Poměr napětí / Umělé sítě, vazební členy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 mV do 1,2 V; 9 kHz do 400 MHz","range":"od 0 dB do 20 dB","cmc":"0,17 dB"},{"name":"1 mV do 1,2 V; 9 kHz do 400 MHz","range":"od 20 dB do 40 dB","cmc":"0,19 dB"},{"name":"0,1 mV do 1,2 V; 9 kHz do 400 MHz","range":"od 40 dB do 50 dB","cmc":"0,30 dB"},{"name":"0,1 mV do 1,2 V; 9 kHz do 400 MHz","range":"od 50 dB do 60 dB","cmc":"0,67 dB"},{"name":"0,1 mV do 1,2 V; 9 kHz do 400 MHz","range":"od 60 dB do 70 dB","cmc":"1,8 dB"},{"name":"0,1 mV do 1,2 V; 9 kHz do 50 MHz","range":"od 70 dB do 80 dB","cmc":"4,7 dB"}],"parameters_en":[{"name":"10 mV to 1,2 V; 9 kHz to 400 MHz","range":"0 dB to 20 dB","cmc":"0,17 dB"},{"name":"1 mV to 1,2 V; 9 kHz to 400 MHz","range":"20 dB to 40 dB","cmc":"0,19 dB"},{"name":"0,1 mV to 1,2 V; 9 kHz to 400 MHz","range":"40 dB to 50 dB","cmc":"0,30 dB"},{"name":"0,1 mV to 1,2 V; 9 kHz to 400 MHz","range":"50 dB to 60 dB","cmc":"0,67 dB"},{"name":"0,1 mV to 1,2 V; 9 kHz to 400 MHz","range":"60 dB to 70 dB","cmc":"1,8 dB"},{"name":"0,1 mV to 1,2 V; 9 kHz to 50 MHz","range":"70 dB to 80 dB","cmc":"4,7 dB"}],"parameters_zh":[{"name":"10 mV 至 1,2 V；9 kHz 至 400 MHz","range":"0 dB 至 20 dB","cmc":"0,17 dB"},{"name":"1 mV 至 1,2 V；9 kHz 至 400 MHz","range":"20 dB 至 40 dB","cmc":"0,19 dB"},{"name":"0,1 mV 至 1,2 V；9 kHz 至 400 MHz","range":"40 dB 至 50 dB","cmc":"0,30 dB"},{"name":"0,1 mV 至 1,2 V；9 kHz 至 400 MHz","range":"50 dB 至 60 dB","cmc":"0,67 dB"},{"name":"0,1 mV 至 1,2 V；9 kHz 至 400 MHz","range":"60 dB 至 70 dB","cmc":"1,8 dB"},{"name":"0,1 mV 至 1,2 V；9 kHz 至 50 MHz","range":"70 dB 至 80 dB","cmc":"4,7 dB"}],"parameters_cs":[{"name":"10 mV až 1,2 V; 9 kHz až 400 MHz","range":"0 dB až 20 dB","cmc":"0,17 dB"},{"name":"1 mV až 1,2 V; 9 kHz až 400 MHz","range":"20 dB až 40 dB","cmc":"0,19 dB"},{"name":"0,1 mV až 1,2 V; 9 kHz až 400 MHz","range":"40 dB až 50 dB","cmc":"0,30 dB"},{"name":"0,1 mV až 1,2 V; 9 kHz až 400 MHz","range":"50 dB až 60 dB","cmc":"0,67 dB"},{"name":"0,1 mV až 1,2 V; 9 kHz až 400 MHz","range":"60 dB až 70 dB","cmc":"1,8 dB"},{"name":"0,1 mV až 1,2 V; 9 kHz až 50 MHz","range":"70 dB až 80 dB","cmc":"4,7 dB"}],"technique":"Stosunek napięć zmierzonych watomierzem wzorcowym na wejściowym członie T i na wyjściu 50 Ω, po przeliczeniu z mocy i impedancji","technique_en":"Ratio of voltages measured by a standard power meter at the input T-section and at the 50 Ω output, calculated from power and impedance","technique_zh":"用标准功率计在输入 T 形节和 50 Ω 输出端测得的电压之比（由功率和阻抗换算）","technique_cs":"Poměr napětí změřených etalonovým wattmetrem na vstupním T – článku a na 50 Ω výstupu, po přepočtu z výkonu a impedance","techniques":["Stosunek napięć zmierzonych watomierzem wzorcowym na wejściowym członie T i na wyjściu 50 Ω, po przeliczeniu z mocy i impedancji"],"techniques_en":["Ratio of voltages measured by a standard power meter at the input T-section and at the 50 Ω output, calculated from power and impedance"],"techniques_zh":["用标准功率计在输入 T 形节和 50 Ω 输出端测得的电压之比（由功率和阻抗换算）"],"techniques_cs":["Poměr napětí změřených etalonovým wattmetrem na vstupním T – článku a na 50 Ω výstupu, po přepočtu z výkonu a impedance"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 mV do 1,2 V; 9 kHz do 400 MHz od 0 dB do 20 dB CMC 0,17 dB\n1 mV do 1,2 V; 9 kHz do 400 MHz od 20 dB do 40 dB CMC 0,19 dB\n0,1 mV do 1,2 V; 9 kHz do 400 MHz od 40 dB do 50 dB CMC 0,30 dB\n0,1 mV do 1,2 V; 9 kHz do 400 MHz od 50 dB do 60 dB CMC 0,67 dB\n0,1 mV do 1,2 V; 9 kHz do 400 MHz od 60 dB do 70 dB CMC 1,8 dB\n0,1 mV do 1,2 V; 9 kHz do 50 MHz od 70 dB do 80 dB CMC 4,7 dB\nStosunek napięć zmierzonych watomierzem wzorcowym na wejściowym członie T i na wyjściu 50 Ω, po przeliczeniu z mocy i impedancji","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stosunek napięć / sztuczne sieci, człony sprzęgające Wzorcowanie – wielkości elektryczne Stosunek napięć zmierzonych watomierzem wzorcowym na wejściowym członie T i na wyjściu 50 Ω, po przeliczeniu z mocy i impedancji 10 mV do 1,2 V; 9 kHz do 400 MHz od 0 dB do 20 dB CMC 0,17 dB 1 mV do 1,2 V; 9 kHz do 400 MHz od 20 dB do 40 dB CMC 0,19 dB 0,1 mV do 1,2 V; 9 kHz do 400 MHz od 40 dB do 50 dB CMC 0,30 dB 0,1 mV do 1,2 V; 9 kHz do 400 MHz od 50 dB do 60 dB CMC 0,67 dB 0,1 mV do 1,2 V; 9 kHz do 400 MHz od 60 dB do 70 dB CMC 1,8 dB 0,1 mV do 1,2 V; 9 kHz do 50 MHz od 70 dB do 80 dB CMC 4,7 dB Poměr napětí / Umělé sítě, vazební členy Kalibrace – elektrické veličiny Poměr napětí změřených etalonovým wattmetrem na vstupním T – článku a na 50 Ω výstupu, po přepočtu z výkonu a impedance 10 mV až 1,2 V; 9 kHz až 400 MHz 0 dB až 20 dB CMC 0,17 dB 1 mV až 1,2 V; 9 kHz až 400 MHz 20 dB až 40 dB CMC 0,19 dB 0,1 mV až 1,2 V; 9 kHz až 400 MHz 40 dB až 50 dB CMC 0,30 dB 0,1 mV až 1,2 V; 9 kHz až 400 MHz 50 dB až 60 dB CMC 0,67 dB 0,1 mV až 1,2 V; 9 kHz až 400 MHz 60 dB až 70 dB CMC 1,8 dB 0,1 mV až 1,2 V; 9 kHz až 50 MHz 70 dB až 80 dB CMC 4,7 dB MK16 Stosunek napiec / sztuczne sieci, czlony sprzegajace Wzorcowanie – wielkosci elektryczne Stosunek napiec zmierzonych watomierzem wzorcowym na wejsciowym czlonie T i na wyjsciu 50 Ω, po przeliczeniu z mocy i impedancji 10 mV do 1,2 V; 9 kHz do 400 MHz od 0 dB do 20 dB CMC 0,17 dB 1 mV do 1,2 V; 9 kHz do 400 MHz od 20 dB do 40 dB CMC 0,19 dB 0,1 mV do 1,2 V; 9 kHz do 400 MHz od 40 dB do 50 dB CMC 0,30 dB 0,1 mV do 1,2 V; 9 kHz do 400 MHz od 50 dB do 60 dB CMC 0,67 dB 0,1 mV do 1,2 V; 9 kHz do 400 MHz od 60 dB do 70 dB CMC 1,8 dB 0,1 mV do 1,2 V; 9 kHz do 50 MHz od 70 dB do 80 dB CMC 4,7 dB Pomer napeti / Umele site, vazebni cleny Kalibrace – elektricke veliciny Pomer napeti zmerenych etalonovym wattmetrem na vstupnim T – clanku a na 50 Ω vystupu, po prepoctu z vykonu a impedance 10 mV az 1,2 V; 9 kHz az 400 MHz 0 dB az 20 dB CMC 0,17 dB 1 mV az 1,2 V; 9 kHz az 400 MHz 20 dB az 40 dB CMC 0,19 dB 0,1 mV az 1,2 V; 9 kHz az 400 MHz 40 dB az 50 dB CMC 0,30 dB 0,1 mV az 1,2 V; 9 kHz az 400 MHz 50 dB az 60 dB CMC 0,67 dB 0,1 mV az 1,2 V; 9 kHz az 400 MHz 60 dB az 70 dB CMC 1,8 dB 0,1 mV az 1,2 V; 9 kHz az 50 MHz 70 dB az 80 dB CMC 4,7 dB MK16","search_en":"Voltage ratio / Artificial networks, coupling networks Calibration – electrical quantities Ratio of voltages measured by a standard power meter at the input T-section and at the 50 Ω output, calculated from power and impedance 10 mV to 1,2 V; 9 kHz to 400 MHz 0 dB to 20 dB CMC 0,17 dB 1 mV to 1,2 V; 9 kHz to 400 MHz 20 dB to 40 dB CMC 0,19 dB 0,1 mV to 1,2 V; 9 kHz to 400 MHz 40 dB to 50 dB CMC 0,30 dB 0,1 mV to 1,2 V; 9 kHz to 400 MHz 50 dB to 60 dB CMC 0,67 dB 0,1 mV to 1,2 V; 9 kHz to 400 MHz 60 dB to 70 dB CMC 1,8 dB 0,1 mV to 1,2 V; 9 kHz to 50 MHz 70 dB to 80 dB CMC 4,7 dB MK16","search_zh":"电压比 / 人工电源网络、耦合网络 校准 – 电学量 用标准功率计在输入 T 形节和 50 Ω 输出端测得的电压之比（由功率和阻抗换算） 10 mV 至 1,2 V；9 kHz 至 400 MHz 0 dB 至 20 dB CMC 0,17 dB 1 mV 至 1,2 V；9 kHz 至 400 MHz 20 dB 至 40 dB CMC 0,19 dB 0,1 mV 至 1,2 V；9 kHz 至 400 MHz 40 dB 至 50 dB CMC 0,30 dB 0,1 mV 至 1,2 V；9 kHz 至 400 MHz 50 dB 至 60 dB CMC 0,67 dB 0,1 mV 至 1,2 V；9 kHz 至 400 MHz 60 dB 至 70 dB CMC 1,8 dB 0,1 mV 至 1,2 V；9 kHz 至 50 MHz 70 dB 至 80 dB CMC 4,7 dB MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1d743d2a177bd1ed4ebc5be6","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"31","test_object":"Stosunek mocy / tłumiki, wzmacniacze, człony sprzęgające, inne urządzenia w.cz.","test_object_en":"Power ratio / Attenuators, amplifiers, coupling networks, other RF equipment","test_object_zh":"功率比 / 衰减器、放大器、耦合网络、其他射频设备","test_object_cs":"Poměr výkonů / Útlumové články, zesilovače, vazební členy, další vf zařízení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 nW do 5,5 mW, złącze: N; 9 kHz do 100 MHz","range":"od 0 dB do 50 dB","cmc":"0,09 dB"},{"name":"1 nW do 5,5 mW, złącze: N; 100 MHz do 4 GHz","range":"od 0 dB do 50 dB","cmc":"0,10 dB"},{"name":"1 nW do 5,5 mW, złącze: N; 4 GHz do 6 GHz","range":"od 0 dB do 50 dB","cmc":"0,12 dB"},{"name":"1 nW do 5,5 mW, złącze: N; 9 kHz do 100 MHz","range":"od 50 dB do 60 dB","cmc":"0,15 dB"},{"name":"1 nW do 5,5 mW, złącze: N; 100 MHz do 4 GHz","range":"od 50 dB do 60 dB","cmc":"0,16 dB"},{"name":"1 nW do 5,5 mW, złącze: N; 4 GHz do 6 GHz","range":"od 50 dB do 60 dB","cmc":"0,18 dB"}],"parameters_en":[{"name":"1 nW to 5,5 mW, connector: N; 9 kHz to 100 MHz","range":"0 dB to 50 dB","cmc":"0,09 dB"},{"name":"1 nW to 5,5 mW, connector: N; 100 MHz to 4 GHz","range":"0 dB to 50 dB","cmc":"0,10 dB"},{"name":"1 nW to 5,5 mW, connector: N; 4 GHz to 6 GHz","range":"0 dB to 50 dB","cmc":"0,12 dB"},{"name":"1 nW to 5,5 mW, connector: N; 9 kHz to 100 MHz","range":"50 dB to 60 dB","cmc":"0,15 dB"},{"name":"1 nW to 5,5 mW, connector: N; 100 MHz to 4 GHz","range":"50 dB to 60 dB","cmc":"0,16 dB"},{"name":"1 nW to 5,5 mW, connector: N; 4 GHz to 6 GHz","range":"50 dB to 60 dB","cmc":"0,18 dB"}],"parameters_zh":[{"name":"1 nW 至 5,5 mW，连接器：N；9 kHz 至 100 MHz","range":"0 dB 至 50 dB","cmc":"0,09 dB"},{"name":"1 nW 至 5,5 mW，连接器：N；100 MHz 至 4 GHz","range":"0 dB 至 50 dB","cmc":"0,10 dB"},{"name":"1 nW 至 5,5 mW，连接器：N；4 GHz 至 6 GHz","range":"0 dB 至 50 dB","cmc":"0,12 dB"},{"name":"1 nW 至 5,5 mW，连接器：N；9 kHz 至 100 MHz","range":"50 dB 至 60 dB","cmc":"0,15 dB"},{"name":"1 nW 至 5,5 mW，连接器：N；100 MHz 至 4 GHz","range":"50 dB 至 60 dB","cmc":"0,16 dB"},{"name":"1 nW 至 5,5 mW，连接器：N；4 GHz 至 6 GHz","range":"50 dB 至 60 dB","cmc":"0,18 dB"}],"parameters_cs":[{"name":"1 nW až 5,5 mW, konektor: N; 9 kHz až 100 MHz","range":"0 dB až 50 dB","cmc":"0,09 dB"},{"name":"1 nW až 5,5 mW, konektor: N; 100 MHz až 4 GHz","range":"0 dB až 50 dB","cmc":"0,10 dB"},{"name":"1 nW až 5,5 mW, konektor: N; 4 GHz až 6 GHz","range":"0 dB až 50 dB","cmc":"0,12 dB"},{"name":"1 nW až 5,5 mW, konektor: N; 9 kHz až 100 MHz","range":"50 dB až 60 dB","cmc":"0,15 dB"},{"name":"1 nW až 5,5 mW, konektor: N; 100 MHz až 4 GHz","range":"50 dB až 60 dB","cmc":"0,16 dB"},{"name":"1 nW až 5,5 mW, konektor: N; 4 GHz až 6 GHz","range":"50 dB až 60 dB","cmc":"0,18 dB"}],"technique":"Stosunek mocy zmierzonych watomierzem wzorcowym","technique_en":"Ratio of powers measured by a standard power meter","technique_zh":"用标准功率计测得的功率之比","technique_cs":"Poměr výkonů změřených etalonovým wattmetrem","techniques":["Stosunek mocy zmierzonych watomierzem wzorcowym"],"techniques_en":["Ratio of powers measured by a standard power meter"],"techniques_zh":["用标准功率计测得的功率之比"],"techniques_cs":["Poměr výkonů změřených etalonovým wattmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 nW do 5,5 mW, złącze: N; 9 kHz do 100 MHz od 0 dB do 50 dB CMC 0,09 dB\n1 nW do 5,5 mW, złącze: N; 100 MHz do 4 GHz od 0 dB do 50 dB CMC 0,10 dB\n1 nW do 5,5 mW, złącze: N; 4 GHz do 6 GHz od 0 dB do 50 dB CMC 0,12 dB\n1 nW do 5,5 mW, złącze: N; 9 kHz do 100 MHz od 50 dB do 60 dB CMC 0,15 dB\n1 nW do 5,5 mW, złącze: N; 100 MHz do 4 GHz od 50 dB do 60 dB CMC 0,16 dB\n1 nW do 5,5 mW, złącze: N; 4 GHz do 6 GHz od 50 dB do 60 dB CMC 0,18 dB\nStosunek mocy zmierzonych watomierzem wzorcowym","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":"Można użyć także innego rodzaju złącza, ale niepewność będzie wtedy większa.","note_en":"Another type of connector may also be used, but the uncertainty will be higher.","note_zh":"也可使用其他类型的连接器，但不确定度会更高。","note_cs":"Lze použít i jiný druh konektoru, ale hodnota nejistoty bude vyšší.","search_text":"Stosunek mocy / tłumiki, wzmacniacze, człony sprzęgające, inne urządzenia w.cz. Wzorcowanie – wielkości elektryczne Stosunek mocy zmierzonych watomierzem wzorcowym 1 nW do 5,5 mW, złącze: N; 9 kHz do 100 MHz od 0 dB do 50 dB CMC 0,09 dB 1 nW do 5,5 mW, złącze: N; 100 MHz do 4 GHz od 0 dB do 50 dB CMC 0,10 dB 1 nW do 5,5 mW, złącze: N; 4 GHz do 6 GHz od 0 dB do 50 dB CMC 0,12 dB 1 nW do 5,5 mW, złącze: N; 9 kHz do 100 MHz od 50 dB do 60 dB CMC 0,15 dB 1 nW do 5,5 mW, złącze: N; 100 MHz do 4 GHz od 50 dB do 60 dB CMC 0,16 dB 1 nW do 5,5 mW, złącze: N; 4 GHz do 6 GHz od 50 dB do 60 dB CMC 0,18 dB Poměr výkonů / Útlumové články, zesilovače, vazební členy, další vf zařízení Kalibrace – elektrické veličiny Poměr výkonů změřených etalonovým wattmetrem 1 nW až 5,5 mW, konektor: N; 9 kHz až 100 MHz 0 dB až 50 dB CMC 0,09 dB 1 nW až 5,5 mW, konektor: N; 100 MHz až 4 GHz 0 dB až 50 dB CMC 0,10 dB 1 nW až 5,5 mW, konektor: N; 4 GHz až 6 GHz 0 dB až 50 dB CMC 0,12 dB 1 nW až 5,5 mW, konektor: N; 9 kHz až 100 MHz 50 dB až 60 dB CMC 0,15 dB 1 nW až 5,5 mW, konektor: N; 100 MHz až 4 GHz 50 dB až 60 dB CMC 0,16 dB 1 nW až 5,5 mW, konektor: N; 4 GHz až 6 GHz 50 dB až 60 dB CMC 0,18 dB MK16 Stosunek mocy / tlumiki, wzmacniacze, czlony sprzegajace, inne urzadzenia w.cz. Wzorcowanie – wielkosci elektryczne Stosunek mocy zmierzonych watomierzem wzorcowym 1 nW do 5,5 mW, zlacze: N; 9 kHz do 100 MHz od 0 dB do 50 dB CMC 0,09 dB 1 nW do 5,5 mW, zlacze: N; 100 MHz do 4 GHz od 0 dB do 50 dB CMC 0,10 dB 1 nW do 5,5 mW, zlacze: N; 4 GHz do 6 GHz od 0 dB do 50 dB CMC 0,12 dB 1 nW do 5,5 mW, zlacze: N; 9 kHz do 100 MHz od 50 dB do 60 dB CMC 0,15 dB 1 nW do 5,5 mW, zlacze: N; 100 MHz do 4 GHz od 50 dB do 60 dB CMC 0,16 dB 1 nW do 5,5 mW, zlacze: N; 4 GHz do 6 GHz od 50 dB do 60 dB CMC 0,18 dB Pomer vykonu / Utlumove clanky, zesilovace, vazebni cleny, dalsi vf zarizeni Kalibrace – elektricke veliciny Pomer vykonu zmerenych etalonovym wattmetrem 1 nW az 5,5 mW, konektor: N; 9 kHz az 100 MHz 0 dB az 50 dB CMC 0,09 dB 1 nW az 5,5 mW, konektor: N; 100 MHz az 4 GHz 0 dB az 50 dB CMC 0,10 dB 1 nW az 5,5 mW, konektor: N; 4 GHz az 6 GHz 0 dB az 50 dB CMC 0,12 dB 1 nW az 5,5 mW, konektor: N; 9 kHz az 100 MHz 50 dB az 60 dB CMC 0,15 dB 1 nW az 5,5 mW, konektor: N; 100 MHz az 4 GHz 50 dB az 60 dB CMC 0,16 dB 1 nW az 5,5 mW, konektor: N; 4 GHz az 6 GHz 50 dB az 60 dB CMC 0,18 dB MK16","search_en":"Power ratio / Attenuators, amplifiers, coupling networks, other RF equipment Calibration – electrical quantities Ratio of powers measured by a standard power meter 1 nW to 5,5 mW, connector: N; 9 kHz to 100 MHz 0 dB to 50 dB CMC 0,09 dB 1 nW to 5,5 mW, connector: N; 100 MHz to 4 GHz 0 dB to 50 dB CMC 0,10 dB 1 nW to 5,5 mW, connector: N; 4 GHz to 6 GHz 0 dB to 50 dB CMC 0,12 dB 1 nW to 5,5 mW, connector: N; 9 kHz to 100 MHz 50 dB to 60 dB CMC 0,15 dB 1 nW to 5,5 mW, connector: N; 100 MHz to 4 GHz 50 dB to 60 dB CMC 0,16 dB 1 nW to 5,5 mW, connector: N; 4 GHz to 6 GHz 50 dB to 60 dB CMC 0,18 dB MK16","search_zh":"功率比 / 衰减器、放大器、耦合网络、其他射频设备 校准 – 电学量 用标准功率计测得的功率之比 1 nW 至 5,5 mW，连接器：N；9 kHz 至 100 MHz 0 dB 至 50 dB CMC 0,09 dB 1 nW 至 5,5 mW，连接器：N；100 MHz 至 4 GHz 0 dB 至 50 dB CMC 0,10 dB 1 nW 至 5,5 mW，连接器：N；4 GHz 至 6 GHz 0 dB 至 50 dB CMC 0,12 dB 1 nW 至 5,5 mW，连接器：N；9 kHz 至 100 MHz 50 dB 至 60 dB CMC 0,15 dB 1 nW 至 5,5 mW，连接器：N；100 MHz 至 4 GHz 50 dB 至 60 dB CMC 0,16 dB 1 nW 至 5,5 mW，连接器：N；4 GHz 至 6 GHz 50 dB 至 60 dB CMC 0,18 dB MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"40f8f44c19e52829e6a16529","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"32","test_object":"Impedancja przejściowa / sondy prądowe","test_object_en":"Transfer impedance / Current probes","test_object_zh":"转移阻抗 / 电流探头","test_object_cs":"Přenosová impedance / Proudové sondy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"3 A do 11 A; 45 Hz do 5 kHz","range":"od -65 dB(Ω) do -40 dB(Ω)","cmc":"0,16 dB"},{"name":"0,3 A do 3 A; 45 Hz do 5 kHz","range":"od -40 dB(Ω) do 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA do 0,3 A; 45 Hz do 30 kHz","range":"od -40 dB(Ω) do 20 dB(Ω)","cmc":"0,17 dB"}],"parameters_en":[{"name":"3 A to 11 A; 45 Hz to 5 kHz","range":"-65 dB(Ω) to -40 dB(Ω)","cmc":"0,16 dB"},{"name":"0,3 A to 3 A; 45 Hz to 5 kHz","range":"-40 dB(Ω) to 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA to 0,3 A; 45 Hz to 30 kHz","range":"-40 dB(Ω) to 20 dB(Ω)","cmc":"0,17 dB"}],"parameters_zh":[{"name":"3 A 至 11 A；45 Hz 至 5 kHz","range":"-65 dB(Ω) 至 -40 dB(Ω)","cmc":"0,16 dB"},{"name":"0,3 A 至 3 A；45 Hz 至 5 kHz","range":"-40 dB(Ω) 至 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA 至 0,3 A；45 Hz 至 30 kHz","range":"-40 dB(Ω) 至 20 dB(Ω)","cmc":"0,17 dB"}],"parameters_cs":[{"name":"3 A až 11 A; 45 Hz až 5 kHz","range":"-65 dB(Ω) až -40 dB(Ω)","cmc":"0,16 dB"},{"name":"0,3 A až 3 A; 45 Hz až 5 kHz","range":"-40 dB(Ω) až 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA až 0,3 A; 45 Hz až 30 kHz","range":"-40 dB(Ω) až 20 dB(Ω)","cmc":"0,17 dB"}],"technique":"Stosunek napięcia i prądu zmierzonych z użyciem woltomierza wzorcowego i kalibratora wzorcowego","technique_en":"Ratio of voltage and current measured using a standard voltmeter and a standard calibrator","technique_zh":"使用标准电压表和标准校准器测得的电压与电流之比","technique_cs":"Poměr napětí a proudu změřených s užitím etalonového voltmetru a etalonového kalibrátoru","techniques":["Stosunek napięcia i prądu zmierzonych z użyciem woltomierza wzorcowego i kalibratora wzorcowego"],"techniques_en":["Ratio of voltage and current measured using a standard voltmeter and a standard calibrator"],"techniques_zh":["使用标准电压表和标准校准器测得的电压与电流之比"],"techniques_cs":["Poměr napětí a proudu změřených s užitím etalonového voltmetru a etalonového kalibrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n3 A do 11 A; 45 Hz do 5 kHz od -65 dB(Ω) do -40 dB(Ω) CMC 0,16 dB\n0,3 A do 3 A; 45 Hz do 5 kHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB\n2 mA do 0,3 A; 45 Hz do 30 kHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,17 dB\nStosunek napięcia i prądu zmierzonych z użyciem woltomierza wzorcowego i kalibratora wzorcowego","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja przejściowa / sondy prądowe Wzorcowanie – wielkości elektryczne Stosunek napięcia i prądu zmierzonych z użyciem woltomierza wzorcowego i kalibratora wzorcowego 3 A do 11 A; 45 Hz do 5 kHz od -65 dB(Ω) do -40 dB(Ω) CMC 0,16 dB 0,3 A do 3 A; 45 Hz do 5 kHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB 2 mA do 0,3 A; 45 Hz do 30 kHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,17 dB Přenosová impedance / Proudové sondy Kalibrace – elektrické veličiny Poměr napětí a proudu změřených s užitím etalonového voltmetru a etalonového kalibrátoru 3 A až 11 A; 45 Hz až 5 kHz -65 dB(Ω) až -40 dB(Ω) CMC 0,16 dB 0,3 A až 3 A; 45 Hz až 5 kHz -40 dB(Ω) až 20 dB(Ω) CMC 0,18 dB 2 mA až 0,3 A; 45 Hz až 30 kHz -40 dB(Ω) až 20 dB(Ω) CMC 0,17 dB MK16 Impedancja przejsciowa / sondy pradowe Wzorcowanie – wielkosci elektryczne Stosunek napiecia i pradu zmierzonych z uzyciem woltomierza wzorcowego i kalibratora wzorcowego 3 A do 11 A; 45 Hz do 5 kHz od -65 dB(Ω) do -40 dB(Ω) CMC 0,16 dB 0,3 A do 3 A; 45 Hz do 5 kHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB 2 mA do 0,3 A; 45 Hz do 30 kHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,17 dB Prenosova impedance / Proudove sondy Kalibrace – elektricke veliciny Pomer napeti a proudu zmerenych s uzitim etalonoveho voltmetru a etalonoveho kalibratoru 3 A az 11 A; 45 Hz az 5 kHz -65 dB(Ω) az -40 dB(Ω) CMC 0,16 dB 0,3 A az 3 A; 45 Hz az 5 kHz -40 dB(Ω) az 20 dB(Ω) CMC 0,18 dB 2 mA az 0,3 A; 45 Hz az 30 kHz -40 dB(Ω) az 20 dB(Ω) CMC 0,17 dB MK16","search_en":"Transfer impedance / Current probes Calibration – electrical quantities Ratio of voltage and current measured using a standard voltmeter and a standard calibrator 3 A to 11 A; 45 Hz to 5 kHz -65 dB(Ω) to -40 dB(Ω) CMC 0,16 dB 0,3 A to 3 A; 45 Hz to 5 kHz -40 dB(Ω) to 20 dB(Ω) CMC 0,18 dB 2 mA to 0,3 A; 45 Hz to 30 kHz -40 dB(Ω) to 20 dB(Ω) CMC 0,17 dB MK16","search_zh":"转移阻抗 / 电流探头 校准 – 电学量 使用标准电压表和标准校准器测得的电压与电流之比 3 A 至 11 A；45 Hz 至 5 kHz -65 dB(Ω) 至 -40 dB(Ω) CMC 0,16 dB 0,3 A 至 3 A；45 Hz 至 5 kHz -40 dB(Ω) 至 20 dB(Ω) CMC 0,18 dB 2 mA 至 0,3 A；45 Hz 至 30 kHz -40 dB(Ω) 至 20 dB(Ω) CMC 0,17 dB MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"38ee3f7db17538cfb5188232","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"32","test_object":"Impedancja przejściowa / sondy prądowe","test_object_en":"Transfer impedance / Current probes","test_object_zh":"转移阻抗 / 电流探头","test_object_cs":"Přenosová impedance / Proudové sondy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"2 mA do 70 mA; 30 kHz do 50 MHz","range":"od -40 dB(Ω) do 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA do 40 mA; 50 MHz do 100 MHz","range":"od -40 dB(Ω) do 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA do 40 mA; 100 MHz do 250 MHz","range":"od -40 dB(Ω) do 20 dB(Ω)","cmc":"0,22 dB"},{"name":"2 mA do 20 mA; 250 MHz do 1 GHz","range":"od -40 dB(Ω) do 20 dB(Ω)","cmc":"0,33 dB"}],"parameters_en":[{"name":"2 mA to 70 mA; 30 kHz to 50 MHz","range":"-40 dB(Ω) to 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA to 40 mA; 50 MHz to 100 MHz","range":"-40 dB(Ω) to 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA to 40 mA; 100 MHz to 250 MHz","range":"-40 dB(Ω) to 20 dB(Ω)","cmc":"0,22 dB"},{"name":"2 mA to 20 mA; 250 MHz to 1 GHz","range":"-40 dB(Ω) to 20 dB(Ω)","cmc":"0,33 dB"}],"parameters_zh":[{"name":"2 mA 至 70 mA；30 kHz 至 50 MHz","range":"-40 dB(Ω) 至 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA 至 40 mA；50 MHz 至 100 MHz","range":"-40 dB(Ω) 至 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA 至 40 mA；100 MHz 至 250 MHz","range":"-40 dB(Ω) 至 20 dB(Ω)","cmc":"0,22 dB"},{"name":"2 mA 至 20 mA；250 MHz 至 1 GHz","range":"-40 dB(Ω) 至 20 dB(Ω)","cmc":"0,33 dB"}],"parameters_cs":[{"name":"2 mA až 70 mA; 30 kHz až 50 MHz","range":"-40 dB(Ω) až 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA až 40 mA; 50 MHz až 100 MHz","range":"-40 dB(Ω) až 20 dB(Ω)","cmc":"0,18 dB"},{"name":"2 mA až 40 mA; 100 MHz až 250 MHz","range":"-40 dB(Ω) až 20 dB(Ω)","cmc":"0,22 dB"},{"name":"2 mA až 20 mA; 250 MHz až 1 GHz","range":"-40 dB(Ω) až 20 dB(Ω)","cmc":"0,33 dB"}],"technique":"Stosunek napięcia i prądu zmierzonych z użyciem watomierza wzorcowego i przyrządu kalibracyjnego","technique_en":"Ratio of voltage and current measured using a standard power meter and a calibration fixture","technique_zh":"使用标准功率计和校准夹具测得的电压与电流之比","technique_cs":"Poměr napětí a proudu změřených s užitím etalonového wattmetru a kalibračního přípravku","techniques":["Stosunek napięcia i prądu zmierzonych z użyciem watomierza wzorcowego i przyrządu kalibracyjnego"],"techniques_en":["Ratio of voltage and current measured using a standard power meter and a calibration fixture"],"techniques_zh":["使用标准功率计和校准夹具测得的电压与电流之比"],"techniques_cs":["Poměr napětí a proudu změřených s užitím etalonového wattmetru a kalibračního přípravku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n2 mA do 70 mA; 30 kHz do 50 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB\n2 mA do 40 mA; 50 MHz do 100 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB\n2 mA do 40 mA; 100 MHz do 250 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,22 dB\n2 mA do 20 mA; 250 MHz do 1 GHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,33 dB\nStosunek napięcia i prądu zmierzonych z użyciem watomierza wzorcowego i przyrządu kalibracyjnego","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja przejściowa / sondy prądowe Wzorcowanie – wielkości elektryczne Stosunek napięcia i prądu zmierzonych z użyciem watomierza wzorcowego i przyrządu kalibracyjnego 2 mA do 70 mA; 30 kHz do 50 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB 2 mA do 40 mA; 50 MHz do 100 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB 2 mA do 40 mA; 100 MHz do 250 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,22 dB 2 mA do 20 mA; 250 MHz do 1 GHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,33 dB Přenosová impedance / Proudové sondy Kalibrace – elektrické veličiny Poměr napětí a proudu změřených s užitím etalonového wattmetru a kalibračního přípravku 2 mA až 70 mA; 30 kHz až 50 MHz -40 dB(Ω) až 20 dB(Ω) CMC 0,18 dB 2 mA až 40 mA; 50 MHz až 100 MHz -40 dB(Ω) až 20 dB(Ω) CMC 0,18 dB 2 mA až 40 mA; 100 MHz až 250 MHz -40 dB(Ω) až 20 dB(Ω) CMC 0,22 dB 2 mA až 20 mA; 250 MHz až 1 GHz -40 dB(Ω) až 20 dB(Ω) CMC 0,33 dB MK16 Impedancja przejsciowa / sondy pradowe Wzorcowanie – wielkosci elektryczne Stosunek napiecia i pradu zmierzonych z uzyciem watomierza wzorcowego i przyrzadu kalibracyjnego 2 mA do 70 mA; 30 kHz do 50 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB 2 mA do 40 mA; 50 MHz do 100 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,18 dB 2 mA do 40 mA; 100 MHz do 250 MHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,22 dB 2 mA do 20 mA; 250 MHz do 1 GHz od -40 dB(Ω) do 20 dB(Ω) CMC 0,33 dB Prenosova impedance / Proudove sondy Kalibrace – elektricke veliciny Pomer napeti a proudu zmerenych s uzitim etalonoveho wattmetru a kalibracniho pripravku 2 mA az 70 mA; 30 kHz az 50 MHz -40 dB(Ω) az 20 dB(Ω) CMC 0,18 dB 2 mA az 40 mA; 50 MHz az 100 MHz -40 dB(Ω) az 20 dB(Ω) CMC 0,18 dB 2 mA az 40 mA; 100 MHz az 250 MHz -40 dB(Ω) az 20 dB(Ω) CMC 0,22 dB 2 mA az 20 mA; 250 MHz az 1 GHz -40 dB(Ω) az 20 dB(Ω) CMC 0,33 dB MK16","search_en":"Transfer impedance / Current probes Calibration – electrical quantities Ratio of voltage and current measured using a standard power meter and a calibration fixture 2 mA to 70 mA; 30 kHz to 50 MHz -40 dB(Ω) to 20 dB(Ω) CMC 0,18 dB 2 mA to 40 mA; 50 MHz to 100 MHz -40 dB(Ω) to 20 dB(Ω) CMC 0,18 dB 2 mA to 40 mA; 100 MHz to 250 MHz -40 dB(Ω) to 20 dB(Ω) CMC 0,22 dB 2 mA to 20 mA; 250 MHz to 1 GHz -40 dB(Ω) to 20 dB(Ω) CMC 0,33 dB MK16","search_zh":"转移阻抗 / 电流探头 校准 – 电学量 使用标准功率计和校准夹具测得的电压与电流之比 2 mA 至 70 mA；30 kHz 至 50 MHz -40 dB(Ω) 至 20 dB(Ω) CMC 0,18 dB 2 mA 至 40 mA；50 MHz 至 100 MHz -40 dB(Ω) 至 20 dB(Ω) CMC 0,18 dB 2 mA 至 40 mA；100 MHz 至 250 MHz -40 dB(Ω) 至 20 dB(Ω) CMC 0,22 dB 2 mA 至 20 mA；250 MHz 至 1 GHz -40 dB(Ω) 至 20 dB(Ω) CMC 0,33 dB MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26bbdff8477c28e99bac4cc2","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"1","test_object":"Światłość / źródła światłości","test_object_en":"Luminous intensity / Luminous intensity sources","test_object_zh":"发光强度 / 发光强度源","test_object_cs":"Svítivost / Zdroje svítivosti","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 1 cd do 10000 cd","cmc":"1,3 %"}],"parameters_en":[{"name":"","range":"1 cd to 10000 cd","cmc":"1,3 %"}],"parameters_zh":[{"name":"","range":"1 cd 至 10000 cd","cmc":"1,3 %"}],"parameters_cs":[{"name":"","range":"1 cd až 10000 cd","cmc":"1,3 %"}],"technique":"Porównanie z wzorcami światłości","technique_en":"Comparison with luminous intensity standards","technique_zh":"与发光强度标准比较","technique_cs":"Porovnání s etalony svítivosti","techniques":["Porównanie z wzorcami światłości"],"techniques_en":["Comparison with luminous intensity standards"],"techniques_zh":["与发光强度标准比较"],"techniques_cs":["Porovnání s etalony svítivosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nod 1 cd do 10000 cd CMC 1,3 %\nPorównanie z wzorcami światłości","reference":"MK22","norm_bases":["MK22"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Światłość / źródła światłości Wzorcowanie – wielkości optyczne Porównanie z wzorcami światłości od 1 cd do 10000 cd CMC 1,3 % Svítivost / Zdroje svítivosti Kalibrace – optické veličiny Porovnání s etalony svítivosti 1 cd až 10000 cd CMC 1,3 % MK22 Swiatlosc / zrodla swiatlosci Wzorcowanie – wielkosci optyczne Porownanie z wzorcami swiatlosci od 1 cd do 10000 cd CMC 1,3 % Svitivost / Zdroje svitivosti Kalibrace – opticke veliciny Porovnani s etalony svitivosti 1 cd az 10000 cd CMC 1,3 % MK22","search_en":"Luminous intensity / Luminous intensity sources Calibration – optical quantities Comparison with luminous intensity standards 1 cd to 10000 cd CMC 1,3 % MK22","search_zh":"发光强度 / 发光强度源 校准 – 光学量 与发光强度标准比较 1 cd 至 10000 cd CMC 1,3 % MK22","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c9579b44efd7b892b9d50fda","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"2","test_object":"Strumień świetlny / źródła strumienia świetlnego","test_object_en":"Luminous flux / Luminous flux sources","test_object_zh":"光通量 / 光通量源","test_object_cs":"Světelný tok / Zdroje světelného toku","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 50 lm do 20000 lm","cmc":"1,3 %"}],"parameters_en":[{"name":"","range":"50 lm to 20000 lm","cmc":"1,3 %"}],"parameters_zh":[{"name":"","range":"50 lm 至 20000 lm","cmc":"1,3 %"}],"parameters_cs":[{"name":"","range":"50 lm až 20000 lm","cmc":"1,3 %"}],"technique":"Porównanie z wzorcami strumienia świetlnego w kuli całkującej","technique_en":"Comparison with luminous flux standards in an integrating sphere","technique_zh":"在积分球中与光通量标准比较","technique_cs":"Porovnání s etalony světelného toku v kulovém integrátoru","techniques":["Porównanie z wzorcami strumienia świetlnego w kuli całkującej"],"techniques_en":["Comparison with luminous flux standards in an integrating sphere"],"techniques_zh":["在积分球中与光通量标准比较"],"techniques_cs":["Porovnání s etalony světelného toku v kulovém integrátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nod 50 lm do 20000 lm CMC 1,3 %\nPorównanie z wzorcami strumienia świetlnego w kuli całkującej","reference":"MK23","norm_bases":["MK23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Strumień świetlny / źródła strumienia świetlnego Wzorcowanie – wielkości optyczne Porównanie z wzorcami strumienia świetlnego w kuli całkującej od 50 lm do 20000 lm CMC 1,3 % Světelný tok / Zdroje světelného toku Kalibrace – optické veličiny Porovnání s etalony světelného toku v kulovém integrátoru 50 lm až 20000 lm CMC 1,3 % MK23 Strumien swietlny / zrodla strumienia swietlnego Wzorcowanie – wielkosci optyczne Porownanie z wzorcami strumienia swietlnego w kuli calkujacej od 50 lm do 20000 lm CMC 1,3 % Svetelny tok / Zdroje svetelneho toku Kalibrace – opticke veliciny Porovnani s etalony svetelneho toku v kulovem integratoru 50 lm az 20000 lm CMC 1,3 % MK23","search_en":"Luminous flux / Luminous flux sources Calibration – optical quantities Comparison with luminous flux standards in an integrating sphere 50 lm to 20000 lm CMC 1,3 % MK23","search_zh":"光通量 / 光通量源 校准 – 光学量 在积分球中与光通量标准比较 50 lm 至 20000 lm CMC 1,3 % MK23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82324a2b6de1c78c1cb268c7","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"3","test_object":"Temperatura barwowa / źródła temperatury barwowej","test_object_en":"Colour temperature / Colour temperature sources","test_object_zh":"色温 / 色温源","test_object_cs":"Teplota chromatičnosti / Zdroje teploty chromatičnosti","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 2000 K do 2900 K","cmc":"40 K"}],"parameters_en":[{"name":"","range":"2000 K to 2900 K","cmc":"40 K"}],"parameters_zh":[{"name":"","range":"2000 K 至 2900 K","cmc":"40 K"}],"parameters_cs":[{"name":"","range":"2000 K až 2900 K","cmc":"40 K"}],"technique":"Porównanie z wzorcami temperatury barwowej za pomocą filtrów","technique_en":"Comparison with colour temperature standards using filters","technique_zh":"借助滤光片与色温标准比较","technique_cs":"Porovnání s etalony teploty chromatičnosti pomocí filtrů","techniques":["Porównanie z wzorcami temperatury barwowej za pomocą filtrów"],"techniques_en":["Comparison with colour temperature standards using filters"],"techniques_zh":["借助滤光片与色温标准比较"],"techniques_cs":["Porovnání s etalony teploty chromatičnosti pomocí filtrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nod 2000 K do 2900 K CMC 40 K\nPorównanie z wzorcami temperatury barwowej za pomocą filtrów","reference":"MK24","norm_bases":["MK24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura barwowa / źródła temperatury barwowej Wzorcowanie – wielkości optyczne Porównanie z wzorcami temperatury barwowej za pomocą filtrów od 2000 K do 2900 K CMC 40 K Teplota chromatičnosti / Zdroje teploty chromatičnosti Kalibrace – optické veličiny Porovnání s etalony teploty chromatičnosti pomocí filtrů 2000 K až 2900 K CMC 40 K MK24 Temperatura barwowa / zrodla temperatury barwowej Wzorcowanie – wielkosci optyczne Porownanie z wzorcami temperatury barwowej za pomoca filtrow od 2000 K do 2900 K CMC 40 K Teplota chromaticnosti / Zdroje teploty chromaticnosti Kalibrace – opticke veliciny Porovnani s etalony teploty chromaticnosti pomoci filtru 2000 K az 2900 K CMC 40 K MK24","search_en":"Colour temperature / Colour temperature sources Calibration – optical quantities Comparison with colour temperature standards using filters 2000 K to 2900 K CMC 40 K MK24","search_zh":"色温 / 色温源 校准 – 光学量 借助滤光片与色温标准比较 2000 K 至 2900 K CMC 40 K MK24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d3514c60f3a803d40d0a22d","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Natężenie oświetlenia / luksomierze, filtry szare, mierniki przepuszczalności","test_object_en":"Illuminance / Luxmeters, neutral density filters, transmittance meters","test_object_zh":"照度 / 照度计、中性灰滤光片、透射比测量仪","test_object_cs":"Osvětlenost / Luxmetry, šedé filtry, měřiče propustnosti","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 1 lx do 300 lx","cmc":"1,2 %"}],"parameters_en":[{"name":"","range":"1 lx to 300 lx","cmc":"1,2 %"}],"parameters_zh":[{"name":"","range":"1 lx 至 300 lx","cmc":"1,2 %"}],"parameters_cs":[{"name":"","range":"1 lx až 300 lx","cmc":"1,2 %"}],"technique":"Pomiar wzorców światłości na ławie fotometrycznej","technique_en":"Measurement of luminous intensity standards on a photometric bench","technique_zh":"在光度导轨上测量发光强度标准","technique_cs":"Měření etalonů svítivosti na fotometrické lavici","techniques":["Pomiar wzorców światłości na ławie fotometrycznej"],"techniques_en":["Measurement of luminous intensity standards on a photometric bench"],"techniques_zh":["在光度导轨上测量发光强度标准"],"techniques_cs":["Měření etalonů svítivosti na fotometrické lavici"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nod 1 lx do 300 lx CMC 1,2 %\nPomiar wzorców światłości na ławie fotometrycznej","reference":"MK25","norm_bases":["MK25"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Natężenie oświetlenia / luksomierze, filtry szare, mierniki przepuszczalności Wzorcowanie – wielkości optyczne Pomiar wzorców światłości na ławie fotometrycznej od 1 lx do 300 lx CMC 1,2 % Osvětlenost / Luxmetry, šedé filtry, měřiče propustnosti Kalibrace – optické veličiny Měření etalonů svítivosti na fotometrické lavici 1 lx až 300 lx CMC 1,2 % MK25 Natezenie oswietlenia / luksomierze, filtry szare, mierniki przepuszczalnosci Wzorcowanie – wielkosci optyczne Pomiar wzorcow swiatlosci na lawie fotometrycznej od 1 lx do 300 lx CMC 1,2 % Osvetlenost / Luxmetry, sede filtry, merice propustnosti Kalibrace – opticke veliciny Mereni etalonu svitivosti na fotometricke lavici 1 lx az 300 lx CMC 1,2 % MK25","search_en":"Illuminance / Luxmeters, neutral density filters, transmittance meters Calibration – optical quantities Measurement of luminous intensity standards on a photometric bench 1 lx to 300 lx CMC 1,2 % MK25","search_zh":"照度 / 照度计、中性灰滤光片、透射比测量仪 校准 – 光学量 在光度导轨上测量发光强度标准 1 lx 至 300 lx CMC 1,2 % MK25","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0e5519f9e3152ad5a9e95453","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Natężenie oświetlenia / luksomierze, filtry szare, mierniki przepuszczalności","test_object_en":"Illuminance / Luxmeters, neutral density filters, transmittance meters","test_object_zh":"照度 / 照度计、中性灰滤光片、透射比测量仪","test_object_cs":"Osvětlenost / Luxmetry, šedé filtry, měřiče propustnosti","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 300 lx do 10 klx","cmc":"1,5 %"},{"name":"","range":"od 10 klx do 50 klx","cmc":"2,0 %"}],"parameters_en":[{"name":"","range":"300 lx to 10 klx","cmc":"1,5 %"},{"name":"","range":"10 klx to 50 klx","cmc":"2,0 %"}],"parameters_zh":[{"name":"","range":"300 lx 至 10 klx","cmc":"1,5 %"},{"name":"","range":"10 klx 至 50 klx","cmc":"2,0 %"}],"parameters_cs":[{"name":"","range":"300 lx až 10 klx","cmc":"1,5 %"},{"name":"","range":"10 klx až 50 klx","cmc":"2,0 %"}],"technique":"Porównanie z luksomierzem wzorcowym","technique_en":"Comparison with a standard luxmeter","technique_zh":"与标准照度计比较","technique_cs":"Porovnání s etalonovým luxmetrem","techniques":["Porównanie z luksomierzem wzorcowym"],"techniques_en":["Comparison with a standard luxmeter"],"techniques_zh":["与标准照度计比较"],"techniques_cs":["Porovnání s etalonovým luxmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\nod 300 lx do 10 klx CMC 1,5 %\nod 10 klx do 50 klx CMC 2,0 %\nPorównanie z luksomierzem wzorcowym","reference":"MK25","norm_bases":["MK25"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Natężenie oświetlenia / luksomierze, filtry szare, mierniki przepuszczalności Wzorcowanie – wielkości optyczne Porównanie z luksomierzem wzorcowym od 300 lx do 10 klx CMC 1,5 % od 10 klx do 50 klx CMC 2,0 % Osvětlenost / Luxmetry, šedé filtry, měřiče propustnosti Kalibrace – optické veličiny Porovnání s etalonovým luxmetrem 300 lx až 10 klx CMC 1,5 % 10 klx až 50 klx CMC 2,0 % MK25 Natezenie oswietlenia / luksomierze, filtry szare, mierniki przepuszczalnosci Wzorcowanie – wielkosci optyczne Porownanie z luksomierzem wzorcowym od 300 lx do 10 klx CMC 1,5 % od 10 klx do 50 klx CMC 2,0 % Osvetlenost / Luxmetry, sede filtry, merice propustnosti Kalibrace – opticke veliciny Porovnani s etalonovym luxmetrem 300 lx az 10 klx CMC 1,5 % 10 klx az 50 klx CMC 2,0 % MK25","search_en":"Illuminance / Luxmeters, neutral density filters, transmittance meters Calibration – optical quantities Comparison with a standard luxmeter 300 lx to 10 klx CMC 1,5 % 10 klx to 50 klx CMC 2,0 % MK25","search_zh":"照度 / 照度计、中性灰滤光片、透射比测量仪 校准 – 光学量 与标准照度计比较 300 lx 至 10 klx CMC 1,5 % 10 klx 至 50 klx CMC 2,0 % MK25","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4dd1fe91cc092b471969b1da","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Luminancja / luminancjomierze","test_object_en":"Luminance / Luminance meters","test_object_zh":"亮度 / 亮度计","test_object_cs":"Jas / Jasoměry","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 5 cd/m² do 500 cd/m²","cmc":"2,0 %"},{"name":"","range":"od 500 cd/m² do 700 cd/m²","cmc":"3,0 %"}],"parameters_en":[{"name":"","range":"5 cd/m² to 500 cd/m²","cmc":"2,0 %"},{"name":"","range":"500 cd/m² to 700 cd/m²","cmc":"3,0 %"}],"parameters_zh":[{"name":"","range":"5 cd/m² 至 500 cd/m²","cmc":"2,0 %"},{"name":"","range":"500 cd/m² 至 700 cd/m²","cmc":"3,0 %"}],"parameters_cs":[{"name":"","range":"5 cd/m² až 500 cd/m²","cmc":"2,0 %"},{"name":"","range":"500 cd/m² až 700 cd/m²","cmc":"3,0 %"}],"technique":"Pomiar wzorca za pomocą przetwornika natężenie oświetlenia – luminancja","technique_en":"Measurement of a standard using an illuminance–luminance converter","technique_zh":"借助照度–亮度转换器测量标准","technique_cs":"Měření etalonu pomocí převodníku osvětlenost – jas","techniques":["Pomiar wzorca za pomocą przetwornika natężenie oświetlenia – luminancja"],"techniques_en":["Measurement of a standard using an illuminance–luminance converter"],"techniques_zh":["借助照度–亮度转换器测量标准"],"techniques_cs":["Měření etalonu pomocí převodníku osvětlenost – jas"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\nod 5 cd/m² do 500 cd/m² CMC 2,0 %\nod 500 cd/m² do 700 cd/m² CMC 3,0 %\nPomiar wzorca za pomocą przetwornika natężenie oświetlenia – luminancja","reference":"MK26","norm_bases":["MK26"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Luminancja / luminancjomierze Wzorcowanie – wielkości optyczne Pomiar wzorca za pomocą przetwornika natężenie oświetlenia – luminancja od 5 cd/m² do 500 cd/m² CMC 2,0 % od 500 cd/m² do 700 cd/m² CMC 3,0 % Jas / Jasoměry Kalibrace – optické veličiny Měření etalonu pomocí převodníku osvětlenost – jas 5 cd/m² až 500 cd/m² CMC 2,0 % 500 cd/m² až 700 cd/m² CMC 3,0 % MK26 Luminancja / luminancjomierze Wzorcowanie – wielkosci optyczne Pomiar wzorca za pomoca przetwornika natezenie oswietlenia – luminancja od 5 cd/m² do 500 cd/m² CMC 2,0 % od 500 cd/m² do 700 cd/m² CMC 3,0 % Jas / Jasomery Kalibrace – opticke veliciny Mereni etalonu pomoci prevodniku osvetlenost – jas 5 cd/m² az 500 cd/m² CMC 2,0 % 500 cd/m² az 700 cd/m² CMC 3,0 % MK26","search_en":"Luminance / Luminance meters Calibration – optical quantities Measurement of a standard using an illuminance–luminance converter 5 cd/m² to 500 cd/m² CMC 2,0 % 500 cd/m² to 700 cd/m² CMC 3,0 % MK26","search_zh":"亮度 / 亮度计 校准 – 光学量 借助照度–亮度转换器测量标准 5 cd/m² 至 500 cd/m² CMC 2,0 % 500 cd/m² 至 700 cd/m² CMC 3,0 % MK26","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"52bde02a2e74d8d5a142cce1","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Luminancja / luminancjomierze","test_object_en":"Luminance / Luminance meters","test_object_zh":"亮度 / 亮度计","test_object_cs":"Jas / Jasoměry","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"900 cd/m²","cmc":"2,5 %"}],"parameters_en":[{"name":"","range":"900 cd/m²","cmc":"2,5 %"}],"parameters_zh":[{"name":"","range":"900 cd/m²","cmc":"2,5 %"}],"parameters_cs":[{"name":"","range":"900 cd/m²","cmc":"2,5 %"}],"technique":"Pomiar bezpośredni wzorca luminancji","technique_en":"Direct measurement of a luminance standard","technique_zh":"直接测量亮度标准","technique_cs":"Přímé měření etalonu jasu","techniques":["Pomiar bezpośredni wzorca luminancji"],"techniques_en":["Direct measurement of a luminance standard"],"techniques_zh":["直接测量亮度标准"],"techniques_cs":["Přímé měření etalonu jasu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n900 cd/m² CMC 2,5 %\nPomiar bezpośredni wzorca luminancji","reference":"MK26","norm_bases":["MK26"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Luminancja / luminancjomierze Wzorcowanie – wielkości optyczne Pomiar bezpośredni wzorca luminancji 900 cd/m² CMC 2,5 % Jas / Jasoměry Kalibrace – optické veličiny Přímé měření etalonu jasu 900 cd/m² CMC 2,5 % MK26 Luminancja / luminancjomierze Wzorcowanie – wielkosci optyczne Pomiar bezposredni wzorca luminancji 900 cd/m² CMC 2,5 % Jas / Jasomery Kalibrace – opticke veliciny Prime mereni etalonu jasu 900 cd/m² CMC 2,5 % MK26","search_en":"Luminance / Luminance meters Calibration – optical quantities Direct measurement of a luminance standard 900 cd/m² CMC 2,5 % MK26","search_zh":"亮度 / 亮度计 校准 – 光学量 直接测量亮度标准 900 cd/m² CMC 2,5 % MK26","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec7665b836d74f4c20e44643","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / częstościomierze, multimetry, generatory","test_object_en":"Frequency / Counters, multimeters, generators","test_object_zh":"频率 / 计数器、万用表、发生器","test_object_cs":"Frekvence / Čítače, multimetry, generátory","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 0,1 Hz do 3 GHz","cmc":"1·10⁻⁷"}],"parameters_en":[{"name":"","range":"0,1 Hz to 3 GHz","cmc":"1·10⁻⁷"}],"parameters_zh":[{"name":"","range":"0,1 Hz 至 3 GHz","cmc":"1·10⁻⁷"}],"parameters_cs":[{"name":"","range":"0,1 Hz až 3 GHz","cmc":"1·10⁻⁷"}],"technique":"Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard counter: comparison or direct measurement","technique_zh":"标准计数器：比较或直接测量","technique_cs":"Etalonový čítač: porovnání nebo přímé měření","techniques":["Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard counter: comparison or direct measurement"],"techniques_zh":["标准计数器：比较或直接测量"],"techniques_cs":["Etalonový čítač: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 0,1 Hz do 3 GHz CMC 1·10⁻⁷\nCzęstościomierz wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK8, MK17","norm_bases":["MK8","MK17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / częstościomierze, multimetry, generatory Wzorcowanie – wielkości czasu i częstotliwości Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni od 0,1 Hz do 3 GHz CMC 1·10⁻⁷ Frekvence / Čítače, multimetry, generátory Kalibrace – veličiny času a frekvence Etalonový čítač: porovnání nebo přímé měření 0,1 Hz až 3 GHz CMC 1·10⁻⁷ MK8, MK17 Czestotliwosc / czestosciomierze, multimetry, generatory Wzorcowanie – wielkosci czasu i czestotliwosci Czestosciomierz wzorcowy: porownanie lub pomiar bezposredni od 0,1 Hz do 3 GHz CMC 1·10⁻⁷ Frekvence / Citace, multimetry, generatory Kalibrace – veliciny casu a frekvence Etalonovy citac: porovnani nebo prime mereni 0,1 Hz az 3 GHz CMC 1·10⁻⁷ MK8, MK17","search_en":"Frequency / Counters, multimeters, generators Calibration – time and frequency quantities Standard counter: comparison or direct measurement 0,1 Hz to 3 GHz CMC 1·10⁻⁷ MK8, MK17","search_zh":"频率 / 计数器、万用表、发生器 校准 – 时间和频率量 标准计数器：比较或直接测量 0,1 Hz 至 3 GHz CMC 1·10⁻⁷ MK8, MK17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fcf65be98ce0f349f2be2d35","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / częstościomierze, multimetry, generatory","test_object_en":"Frequency / Counters, multimeters, generators","test_object_zh":"频率 / 计数器、万用表、发生器","test_object_cs":"Frekvence / Čítače, multimetry, generátory","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 3 GHz do 6 GHz","cmc":"1·10⁻⁷"}],"parameters_en":[{"name":"","range":"3 GHz to 6 GHz","cmc":"1·10⁻⁷"}],"parameters_zh":[{"name":"","range":"3 GHz 至 6 GHz","cmc":"1·10⁻⁷"}],"parameters_cs":[{"name":"","range":"3 GHz až 6 GHz","cmc":"1·10⁻⁷"}],"technique":"Częstościomierz wzorcowy z dzielnikiem częstotliwości: porównanie lub pomiar bezpośredni","technique_en":"Standard counter with a frequency divider: comparison or direct measurement","technique_zh":"带分频器的标准计数器：比较或直接测量","technique_cs":"Etalonovým čítač s frekvenčním děličem: porovnání nebo přímé měření","techniques":["Częstościomierz wzorcowy z dzielnikiem częstotliwości: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard counter with a frequency divider: comparison or direct measurement"],"techniques_zh":["带分频器的标准计数器：比较或直接测量"],"techniques_cs":["Etalonovým čítač s frekvenčním děličem: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 3 GHz do 6 GHz CMC 1·10⁻⁷\nCzęstościomierz wzorcowy z dzielnikiem częstotliwości: porównanie lub pomiar bezpośredni","reference":"MK8, MK17","norm_bases":["MK8","MK17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / częstościomierze, multimetry, generatory Wzorcowanie – wielkości czasu i częstotliwości Częstościomierz wzorcowy z dzielnikiem częstotliwości: porównanie lub pomiar bezpośredni od 3 GHz do 6 GHz CMC 1·10⁻⁷ Frekvence / Čítače, multimetry, generátory Kalibrace – veličiny času a frekvence Etalonovým čítač s frekvenčním děličem: porovnání nebo přímé měření 3 GHz až 6 GHz CMC 1·10⁻⁷ MK8, MK17 Czestotliwosc / czestosciomierze, multimetry, generatory Wzorcowanie – wielkosci czasu i czestotliwosci Czestosciomierz wzorcowy z dzielnikiem czestotliwosci: porownanie lub pomiar bezposredni od 3 GHz do 6 GHz CMC 1·10⁻⁷ Frekvence / Citace, multimetry, generatory Kalibrace – veliciny casu a frekvence Etalonovym citac s frekvencnim delicem: porovnani nebo prime mereni 3 GHz az 6 GHz CMC 1·10⁻⁷ MK8, MK17","search_en":"Frequency / Counters, multimeters, generators Calibration – time and frequency quantities Standard counter with a frequency divider: comparison or direct measurement 3 GHz to 6 GHz CMC 1·10⁻⁷ MK8, MK17","search_zh":"频率 / 计数器、万用表、发生器 校准 – 时间和频率量 带分频器的标准计数器：比较或直接测量 3 GHz 至 6 GHz CMC 1·10⁻⁷ MK8, MK17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"404ed4d95469d7805c28ff49","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"2","test_object":"Test funkcjonalny częstościomierza (pomiar częstotliwości i okresu)","test_object_en":"Functional test of a counter (frequency and period measurement)","test_object_zh":"计数器功能测试（频率和周期测量）","test_object_cs":"Funkční test čítače (měření frekvence a doby periody)","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 0,1 Hz do 225 MHz","cmc":"2·10⁻⁹"},{"name":"","range":"od 225 MHz do 3 GHz","cmc":"4·10⁻⁹"},{"name":"","range":"od 5 ns do 10 s","cmc":"2·10⁻⁹"}],"parameters_en":[{"name":"","range":"0,1 Hz to 225 MHz","cmc":"2·10⁻⁹"},{"name":"","range":"225 MHz to 3 GHz","cmc":"4·10⁻⁹"},{"name":"","range":"5 ns to 10 s","cmc":"2·10⁻⁹"}],"parameters_zh":[{"name":"","range":"0,1 Hz 至 225 MHz","cmc":"2·10⁻⁹"},{"name":"","range":"225 MHz 至 3 GHz","cmc":"4·10⁻⁹"},{"name":"","range":"5 ns 至 10 s","cmc":"2·10⁻⁹"}],"parameters_cs":[{"name":"","range":"0,1 Hz až 225 MHz","cmc":"2·10⁻⁹"},{"name":"","range":"225 MHz až 3 GHz","cmc":"4·10⁻⁹"},{"name":"","range":"5 ns až 10 s","cmc":"2·10⁻⁹"}],"technique":"Porównanie z częstościomierzem wzorcowym przy podłączonym zewnętrznym wzorcu odniesienia","technique_en":"Comparison with a standard counter with an external reference connected","technique_zh":"在连接外部参考时与标准计数器比较","technique_cs":"Porovnání s etalonovým čítačem při připojené externí referenci","techniques":["Porównanie z częstościomierzem wzorcowym przy podłączonym zewnętrznym wzorcu odniesienia"],"techniques_en":["Comparison with a standard counter with an external reference connected"],"techniques_zh":["在连接外部参考时与标准计数器比较"],"techniques_cs":["Porovnání s etalonovým čítačem při připojené externí referenci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 0,1 Hz do 225 MHz CMC 2·10⁻⁹\nod 225 MHz do 3 GHz CMC 4·10⁻⁹\nod 5 ns do 10 s CMC 2·10⁻⁹\nPorównanie z częstościomierzem wzorcowym przy podłączonym zewnętrznym wzorcu odniesienia","reference":"MK17","norm_bases":["MK17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Test funkcjonalny częstościomierza (pomiar częstotliwości i okresu) Wzorcowanie – wielkości czasu i częstotliwości Porównanie z częstościomierzem wzorcowym przy podłączonym zewnętrznym wzorcu odniesienia od 0,1 Hz do 225 MHz CMC 2·10⁻⁹ od 225 MHz do 3 GHz CMC 4·10⁻⁹ od 5 ns do 10 s CMC 2·10⁻⁹ Funkční test čítače (měření frekvence a doby periody) Kalibrace – veličiny času a frekvence Porovnání s etalonovým čítačem při připojené externí referenci 0,1 Hz až 225 MHz CMC 2·10⁻⁹ 225 MHz až 3 GHz CMC 4·10⁻⁹ 5 ns až 10 s CMC 2·10⁻⁹ MK17 Test funkcjonalny czestosciomierza (pomiar czestotliwosci i okresu) Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z czestosciomierzem wzorcowym przy podlaczonym zewnetrznym wzorcu odniesienia od 0,1 Hz do 225 MHz CMC 2·10⁻⁹ od 225 MHz do 3 GHz CMC 4·10⁻⁹ od 5 ns do 10 s CMC 2·10⁻⁹ Funkcni test citace (mereni frekvence a doby periody) Kalibrace – veliciny casu a frekvence Porovnani s etalonovym citacem pri pripojene externi referenci 0,1 Hz az 225 MHz CMC 2·10⁻⁹ 225 MHz az 3 GHz CMC 4·10⁻⁹ 5 ns az 10 s CMC 2·10⁻⁹ MK17","search_en":"Functional test of a counter (frequency and period measurement) Calibration – time and frequency quantities Comparison with a standard counter with an external reference connected 0,1 Hz to 225 MHz CMC 2·10⁻⁹ 225 MHz to 3 GHz CMC 4·10⁻⁹ 5 ns to 10 s CMC 2·10⁻⁹ MK17","search_zh":"计数器功能测试（频率和周期测量） 校准 – 时间和频率量 在连接外部参考时与标准计数器比较 0,1 Hz 至 225 MHz CMC 2·10⁻⁹ 225 MHz 至 3 GHz CMC 4·10⁻⁹ 5 ns 至 10 s CMC 2·10⁻⁹ MK17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7dd9d2c291d108f45bcc5e03","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"2","test_object":"Test funkcjonalny częstościomierza (pomiar częstotliwości i okresu)","test_object_en":"Functional test of a counter (frequency and period measurement)","test_object_zh":"计数器功能测试（频率和周期测量）","test_object_cs":"Funkční test čítače (měření frekvence a doby periody)","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 3 GHz do 6 GHz","cmc":"5·10⁻⁹"}],"parameters_en":[{"name":"","range":"3 GHz to 6 GHz","cmc":"5·10⁻⁹"}],"parameters_zh":[{"name":"","range":"3 GHz 至 6 GHz","cmc":"5·10⁻⁹"}],"parameters_cs":[{"name":"","range":"3 GHz až 6 GHz","cmc":"5·10⁻⁹"}],"technique":"Porównanie z częstościomierzem wzorcowym z dzielnikiem częstotliwości przy podłączonym zewnętrznym wzorcu odniesienia","technique_en":"Comparison with a standard counter with a frequency divider with an external reference connected","technique_zh":"在连接外部参考时与带分频器的标准计数器比较","technique_cs":"Porovnání s etalonovým čítačem s frekvenčním děličem při připojené externí referenci","techniques":["Porównanie z częstościomierzem wzorcowym z dzielnikiem częstotliwości przy podłączonym zewnętrznym wzorcu odniesienia"],"techniques_en":["Comparison with a standard counter with a frequency divider with an external reference connected"],"techniques_zh":["在连接外部参考时与带分频器的标准计数器比较"],"techniques_cs":["Porovnání s etalonovým čítačem s frekvenčním děličem při připojené externí referenci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 3 GHz do 6 GHz CMC 5·10⁻⁹\nPorównanie z częstościomierzem wzorcowym z dzielnikiem częstotliwości przy podłączonym zewnętrznym wzorcu odniesienia","reference":"MK17","norm_bases":["MK17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Test funkcjonalny częstościomierza (pomiar częstotliwości i okresu) Wzorcowanie – wielkości czasu i częstotliwości Porównanie z częstościomierzem wzorcowym z dzielnikiem częstotliwości przy podłączonym zewnętrznym wzorcu odniesienia od 3 GHz do 6 GHz CMC 5·10⁻⁹ Funkční test čítače (měření frekvence a doby periody) Kalibrace – veličiny času a frekvence Porovnání s etalonovým čítačem s frekvenčním děličem při připojené externí referenci 3 GHz až 6 GHz CMC 5·10⁻⁹ MK17 Test funkcjonalny czestosciomierza (pomiar czestotliwosci i okresu) Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z czestosciomierzem wzorcowym z dzielnikiem czestotliwosci przy podlaczonym zewnetrznym wzorcu odniesienia od 3 GHz do 6 GHz CMC 5·10⁻⁹ Funkcni test citace (mereni frekvence a doby periody) Kalibrace – veliciny casu a frekvence Porovnani s etalonovym citacem s frekvencnim delicem pri pripojene externi referenci 3 GHz az 6 GHz CMC 5·10⁻⁹ MK17","search_en":"Functional test of a counter (frequency and period measurement) Calibration – time and frequency quantities Comparison with a standard counter with a frequency divider with an external reference connected 3 GHz to 6 GHz CMC 5·10⁻⁹ MK17","search_zh":"计数器功能测试（频率和周期测量） 校准 – 时间和频率量 在连接外部参考时与带分频器的标准计数器比较 3 GHz 至 6 GHz CMC 5·10⁻⁹ MK17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9cc2eac16f4aa76e0cd021ac","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"3","test_object":"Pasmo przenoszenia / oscyloskopy","test_object_en":"Bandwidth / Oscilloscopes","test_object_zh":"带宽 / 示波器","test_object_cs":"Šířka pásma / Osciloskopy","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"Spadek 3 dB","range":"od 100 Hz do 100 MHz","cmc":"3 %"},{"name":"Spadek 3 dB","range":"od 100 MHz do 300 MHz","cmc":"4 %"},{"name":"Spadek 3 dB","range":"od 300 MHz do 2 GHz","cmc":"6 %"},{"name":"Spadek 3 dB","range":"od 2 GHz do 6 GHz","cmc":"8 %"}],"parameters_en":[{"name":"3 dB drop","range":"100 Hz to 100 MHz","cmc":"3 %"},{"name":"3 dB drop","range":"100 MHz to 300 MHz","cmc":"4 %"},{"name":"3 dB drop","range":"300 MHz to 2 GHz","cmc":"6 %"},{"name":"3 dB drop","range":"2 GHz to 6 GHz","cmc":"8 %"}],"parameters_zh":[{"name":"下降 3 dB","range":"100 Hz 至 100 MHz","cmc":"3 %"},{"name":"下降 3 dB","range":"100 MHz 至 300 MHz","cmc":"4 %"},{"name":"下降 3 dB","range":"300 MHz 至 2 GHz","cmc":"6 %"},{"name":"下降 3 dB","range":"2 GHz 至 6 GHz","cmc":"8 %"}],"parameters_cs":[{"name":"Pokles 3 dB","range":"100 Hz až 100 MHz","cmc":"3 %"},{"name":"Pokles 3 dB","range":"100 MHz až 300 MHz","cmc":"4 %"},{"name":"Pokles 3 dB","range":"300 MHz až 2 GHz","cmc":"6 %"},{"name":"Pokles 3 dB","range":"2 GHz až 6 GHz","cmc":"8 %"}],"technique":"Pomiar określonego spadku mierzonego poziomu napięcia, prądu lub mocy","technique_en":"Measurement of a defined drop of the measured voltage, current or power level","technique_zh":"测量电压、电流或功率测量电平的规定下降","technique_cs":"Měření definovaného poklesu měřené úrovně napětí, proudu nebo výkonu","techniques":["Pomiar określonego spadku mierzonego poziomu napięcia, prądu lub mocy"],"techniques_en":["Measurement of a defined drop of the measured voltage, current or power level"],"techniques_zh":["测量电压、电流或功率测量电平的规定下降"],"techniques_cs":["Měření definovaného poklesu měřené úrovně napětí, proudu nebo výkonu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nSpadek 3 dB od 100 Hz do 100 MHz CMC 3 %\nSpadek 3 dB od 100 MHz do 300 MHz CMC 4 %\nSpadek 3 dB od 300 MHz do 2 GHz CMC 6 %\nSpadek 3 dB od 2 GHz do 6 GHz CMC 8 %\nPomiar określonego spadku mierzonego poziomu napięcia, prądu lub mocy","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasmo przenoszenia / oscyloskopy Wzorcowanie – wielkości czasu i częstotliwości Pomiar określonego spadku mierzonego poziomu napięcia, prądu lub mocy Spadek 3 dB od 100 Hz do 100 MHz CMC 3 % Spadek 3 dB od 100 MHz do 300 MHz CMC 4 % Spadek 3 dB od 300 MHz do 2 GHz CMC 6 % Spadek 3 dB od 2 GHz do 6 GHz CMC 8 % Šířka pásma / Osciloskopy Kalibrace – veličiny času a frekvence Měření definovaného poklesu měřené úrovně napětí, proudu nebo výkonu Pokles 3 dB 100 Hz až 100 MHz CMC 3 % Pokles 3 dB 100 MHz až 300 MHz CMC 4 % Pokles 3 dB 300 MHz až 2 GHz CMC 6 % Pokles 3 dB 2 GHz až 6 GHz CMC 8 % MK16 Pasmo przenoszenia / oscyloskopy Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar okreslonego spadku mierzonego poziomu napiecia, pradu lub mocy Spadek 3 dB od 100 Hz do 100 MHz CMC 3 % Spadek 3 dB od 100 MHz do 300 MHz CMC 4 % Spadek 3 dB od 300 MHz do 2 GHz CMC 6 % Spadek 3 dB od 2 GHz do 6 GHz CMC 8 % Sirka pasma / Osciloskopy Kalibrace – veliciny casu a frekvence Mereni definovaneho poklesu merene urovne napeti, proudu nebo vykonu Pokles 3 dB 100 Hz az 100 MHz CMC 3 % Pokles 3 dB 100 MHz az 300 MHz CMC 4 % Pokles 3 dB 300 MHz az 2 GHz CMC 6 % Pokles 3 dB 2 GHz az 6 GHz CMC 8 % MK16","search_en":"Bandwidth / Oscilloscopes Calibration – time and frequency quantities Measurement of a defined drop of the measured voltage, current or power level 3 dB drop 100 Hz to 100 MHz CMC 3 % 3 dB drop 100 MHz to 300 MHz CMC 4 % 3 dB drop 300 MHz to 2 GHz CMC 6 % 3 dB drop 2 GHz to 6 GHz CMC 8 % MK16","search_zh":"带宽 / 示波器 校准 – 时间和频率量 测量电压、电流或功率测量电平的规定下降 下降 3 dB 100 Hz 至 100 MHz CMC 3 % 下降 3 dB 100 MHz 至 300 MHz CMC 4 % 下降 3 dB 300 MHz 至 2 GHz CMC 6 % 下降 3 dB 2 GHz 至 6 GHz CMC 8 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a7749dd6c79cb99d4fdd89a2","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Przedział czasu / częstościomierze, generatory","test_object_en":"Time interval / Counters, generators","test_object_zh":"时间间隔 / 计数器、发生器","test_object_cs":"Časový interval / Čítače, generátory","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 5 ns do 10⁵ s","cmc":"(0,9 + 100 T) ns"}],"parameters_en":[{"name":"","range":"5 ns to 10⁵ s","cmc":"(0,9 + 100 T) ns"}],"parameters_zh":[{"name":"","range":"5 ns 至 10⁵ s","cmc":"(0,9 + 100 T) ns"}],"parameters_cs":[{"name":"","range":"5 ns až 10⁵ s","cmc":"(0,9 + 100 T) ns"}],"technique":"Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie napięciem (T w sekundach)","technique_en":"Standard counter: comparison or direct measurement, voltage triggering (T in seconds)","technique_zh":"标准计数器：比较或直接测量，电压触发（T 以秒计）","technique_cs":"Etalonový čítač: porovnání nebo přímé měření, spouštění napětím (T je v sekundách)","techniques":["Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie napięciem (T w sekundach)"],"techniques_en":["Standard counter: comparison or direct measurement, voltage triggering (T in seconds)"],"techniques_zh":["标准计数器：比较或直接测量，电压触发（T 以秒计）"],"techniques_cs":["Etalonový čítač: porovnání nebo přímé měření, spouštění napětím (T je v sekundách)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 5 ns do 10⁵ s CMC (0,9 + 100 T) ns\nCzęstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie napięciem (T w sekundach)","reference":"MK18","norm_bases":["MK18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / częstościomierze, generatory Wzorcowanie – wielkości czasu i częstotliwości Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie napięciem (T w sekundach) od 5 ns do 10⁵ s CMC (0,9 + 100 T) ns Časový interval / Čítače, generátory Kalibrace – veličiny času a frekvence Etalonový čítač: porovnání nebo přímé měření, spouštění napětím (T je v sekundách) 5 ns až 10⁵ s CMC (0,9 + 100 T) ns MK18 Przedzial czasu / czestosciomierze, generatory Wzorcowanie – wielkosci czasu i czestotliwosci Czestosciomierz wzorcowy: porownanie lub pomiar bezposredni, wyzwalanie napieciem (T w sekundach) od 5 ns do 10⁵ s CMC (0,9 + 100 T) ns Casovy interval / Citace, generatory Kalibrace – veliciny casu a frekvence Etalonovy citac: porovnani nebo prime mereni, spousteni napetim (T je v sekundach) 5 ns az 10⁵ s CMC (0,9 + 100 T) ns MK18","search_en":"Time interval / Counters, generators Calibration – time and frequency quantities Standard counter: comparison or direct measurement, voltage triggering (T in seconds) 5 ns to 10⁵ s CMC (0,9 + 100 T) ns MK18","search_zh":"时间间隔 / 计数器、发生器 校准 – 时间和频率量 标准计数器：比较或直接测量，电压触发（T 以秒计） 5 ns 至 10⁵ s CMC (0,9 + 100 T) ns MK18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2ee4045ac4bae5d2741ab468","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Przedział czasu / stopery, czasomierze","test_object_en":"Time interval / Stopwatches, timers","test_object_zh":"时间间隔 / 秒表、计时器","test_object_cs":"Časový interval / Stopky, časovače","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 5 s do 10⁵ s","cmc":"0,05 s"}],"parameters_en":[{"name":"","range":"5 s to 10⁵ s","cmc":"0,05 s"}],"parameters_zh":[{"name":"","range":"5 s 至 10⁵ s","cmc":"0,05 s"}],"parameters_cs":[{"name":"","range":"5 s až 10⁵ s","cmc":"0,05 s"}],"technique":"Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie ręczne","technique_en":"Standard counter: comparison or direct measurement, manual triggering","technique_zh":"标准计数器：比较或直接测量，手动触发","technique_cs":"Etalonový čítač: porovnání nebo přímé měření, ruční spouštění","techniques":["Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie ręczne"],"techniques_en":["Standard counter: comparison or direct measurement, manual triggering"],"techniques_zh":["标准计数器：比较或直接测量，手动触发"],"techniques_cs":["Etalonový čítač: porovnání nebo přímé měření, ruční spouštění"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 5 s do 10⁵ s CMC 0,05 s\nCzęstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie ręczne","reference":"MK18","norm_bases":["MK18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / stopery, czasomierze Wzorcowanie – wielkości czasu i częstotliwości Częstościomierz wzorcowy: porównanie lub pomiar bezpośredni, wyzwalanie ręczne od 5 s do 10⁵ s CMC 0,05 s Časový interval / Stopky, časovače Kalibrace – veličiny času a frekvence Etalonový čítač: porovnání nebo přímé měření, ruční spouštění 5 s až 10⁵ s CMC 0,05 s MK18 Przedzial czasu / stopery, czasomierze Wzorcowanie – wielkosci czasu i czestotliwosci Czestosciomierz wzorcowy: porownanie lub pomiar bezposredni, wyzwalanie reczne od 5 s do 10⁵ s CMC 0,05 s Casovy interval / Stopky, casovace Kalibrace – veliciny casu a frekvence Etalonovy citac: porovnani nebo prime mereni, rucni spousteni 5 s az 10⁵ s CMC 0,05 s MK18","search_en":"Time interval / Stopwatches, timers Calibration – time and frequency quantities Standard counter: comparison or direct measurement, manual triggering 5 s to 10⁵ s CMC 0,05 s MK18","search_zh":"时间间隔 / 秒表、计时器 校准 – 时间和频率量 标准计数器：比较或直接测量，手动触发 5 s 至 10⁵ s CMC 0,05 s MK18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aaed4d658417ba069eb490ae","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"4","test_object":"Przedział czasu / podstawa czasu oscyloskopów","test_object_en":"Time interval / Oscilloscope time base","test_object_zh":"时间间隔 / 示波器时基","test_object_cs":"Časový interval / Časová základna osciloskopů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 2 ns do 100 s","cmc":"0,0025 %"}],"parameters_en":[{"name":"","range":"2 ns to 100 s","cmc":"0,0025 %"}],"parameters_zh":[{"name":"","range":"2 ns 至 100 s","cmc":"0,0025 %"}],"parameters_cs":[{"name":"","range":"2 ns až 100 s","cmc":"0,0025 %"}],"technique":"Pomiar bezpośredni wzorcowego generatora znaczników czasu","technique_en":"Direct measurement of a standard time-mark generator","technique_zh":"直接测量标准时标发生器","technique_cs":"Přímé měření etalonového generátoru časových značek","techniques":["Pomiar bezpośredni wzorcowego generatora znaczników czasu"],"techniques_en":["Direct measurement of a standard time-mark generator"],"techniques_zh":["直接测量标准时标发生器"],"techniques_cs":["Přímé měření etalonového generátoru časových značek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 2 ns do 100 s CMC 0,0025 %\nPomiar bezpośredni wzorcowego generatora znaczników czasu","reference":"MK16","norm_bases":["MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / podstawa czasu oscyloskopów Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni wzorcowego generatora znaczników czasu od 2 ns do 100 s CMC 0,0025 % Časový interval / Časová základna osciloskopů Kalibrace – veličiny času a frekvence Přímé měření etalonového generátoru časových značek 2 ns až 100 s CMC 0,0025 % MK16 Przedzial czasu / podstawa czasu oscyloskopow Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni wzorcowego generatora znacznikow czasu od 2 ns do 100 s CMC 0,0025 % Casovy interval / Casova zakladna osciloskopu Kalibrace – veliciny casu a frekvence Prime mereni etalonoveho generatoru casovych znacek 2 ns az 100 s CMC 0,0025 % MK16","search_en":"Time interval / Oscilloscope time base Calibration – time and frequency quantities Direct measurement of a standard time-mark generator 2 ns to 100 s CMC 0,0025 % MK16","search_zh":"时间间隔 / 示波器时基 校准 – 时间和频率量 直接测量标准时标发生器 2 ns 至 100 s CMC 0,0025 % MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be8680ef409185d53ee2e2aa","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"5","test_object":"Parametry impulsów / oscyloskopy, generatory impulsów, mierniki do badań instalacji","test_object_en":"Pulse parameters / Oscilloscopes, pulse generators, installation testers","test_object_zh":"脉冲参数 / 示波器、脉冲发生器、电气安装测试仪","test_object_cs":"Parametry impulsů / Osciloskopy, generátory impulsů, revizní přístroje","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 0,6 ns do 100 s","cmc":"0,20 % + 0,07 ns"}],"parameters_en":[{"name":"","range":"0,6 ns to 100 s","cmc":"0,20 % + 0,07 ns"}],"parameters_zh":[{"name":"","range":"0,6 ns 至 100 s","cmc":"0,20 % + 0,07 ns"}],"parameters_cs":[{"name":"","range":"0,6 ns až 100 s","cmc":"0,20 % + 0,07 ns"}],"technique":"Oscyloskop wzorcowy: porównanie lub pomiar bezpośredni","technique_en":"Standard oscilloscope: comparison or direct measurement","technique_zh":"标准示波器：比较或直接测量","technique_cs":"Etalonový osciloskop: porovnání nebo přímé měření","techniques":["Oscyloskop wzorcowy: porównanie lub pomiar bezpośredni"],"techniques_en":["Standard oscilloscope: comparison or direct measurement"],"techniques_zh":["标准示波器：比较或直接测量"],"techniques_cs":["Etalonový osciloskop: porovnání nebo přímé měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 0,6 ns do 100 s CMC 0,20 % + 0,07 ns\nOscyloskop wzorcowy: porównanie lub pomiar bezpośredni","reference":"MK11, MK16","norm_bases":["MK11","MK16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Parametry impulsów / oscyloskopy, generatory impulsów, mierniki do badań instalacji Wzorcowanie – wielkości czasu i częstotliwości Oscyloskop wzorcowy: porównanie lub pomiar bezpośredni od 0,6 ns do 100 s CMC 0,20 % + 0,07 ns Parametry impulsů / Osciloskopy, generátory impulsů, revizní přístroje Kalibrace – veličiny času a frekvence Etalonový osciloskop: porovnání nebo přímé měření 0,6 ns až 100 s CMC 0,20 % + 0,07 ns MK11, MK16 Parametry impulsow / oscyloskopy, generatory impulsow, mierniki do badan instalacji Wzorcowanie – wielkosci czasu i czestotliwosci Oscyloskop wzorcowy: porownanie lub pomiar bezposredni od 0,6 ns do 100 s CMC 0,20 % + 0,07 ns Parametry impulsu / Osciloskopy, generatory impulsu, revizni pristroje Kalibrace – veliciny casu a frekvence Etalonovy osciloskop: porovnani nebo prime mereni 0,6 ns az 100 s CMC 0,20 % + 0,07 ns MK11, MK16","search_en":"Pulse parameters / Oscilloscopes, pulse generators, installation testers Calibration – time and frequency quantities Standard oscilloscope: comparison or direct measurement 0,6 ns to 100 s CMC 0,20 % + 0,07 ns MK11, MK16","search_zh":"脉冲参数 / 示波器、脉冲发生器、电气安装测试仪 校准 – 时间和频率量 标准示波器：比较或直接测量 0,6 ns 至 100 s CMC 0,20 % + 0,07 ns MK11, MK16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":92,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f5338721def5d093d669f193","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prędkość obrotowa / obrotomierze, generatory prędkości obrotowej","test_object_en":"Rotational speed / Tachometers, speed generators","test_object_zh":"转速 / 转速表、转速发生器","test_object_cs":"Otáčky / Otáčkoměry, generátory otáček","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 30 min⁻¹ do 300 min⁻¹","cmc":"0,10 %"},{"name":"","range":"od 300 min⁻¹ do 10000 min⁻¹","cmc":"0,050 %"}],"parameters_en":[{"name":"","range":"30 min⁻¹ to 300 min⁻¹","cmc":"0,10 %"},{"name":"","range":"300 min⁻¹ to 10000 min⁻¹","cmc":"0,050 %"}],"parameters_zh":[{"name":"","range":"30 min⁻¹ 至 300 min⁻¹","cmc":"0,10 %"},{"name":"","range":"300 min⁻¹ 至 10000 min⁻¹","cmc":"0,050 %"}],"parameters_cs":[{"name":"","range":"30 min⁻¹ až 300 min⁻¹","cmc":"0,10 %"},{"name":"","range":"300 min⁻¹ až 10000 min⁻¹","cmc":"0,050 %"}],"technique":"Porównanie z częstościomierzem wzorcowym za pomocą urządzenia kalibracyjnego lub pomiar bezpośredni obrotomierzem wzorcowym","technique_en":"Comparison with a standard counter using a calibration device or direct measurement by a standard tachometer","technique_zh":"借助校准装置与标准计数器比较或用标准转速表直接测量","technique_cs":"Porovnání s etalonovým čítačem pomocí kalibračního zařízení nebo přímé měření etalonovým otáčkoměrem","techniques":["Porównanie z częstościomierzem wzorcowym za pomocą urządzenia kalibracyjnego lub pomiar bezpośredni obrotomierzem wzorcowym"],"techniques_en":["Comparison with a standard counter using a calibration device or direct measurement by a standard tachometer"],"techniques_zh":["借助校准装置与标准计数器比较或用标准转速表直接测量"],"techniques_cs":["Porovnání s etalonovým čítačem pomocí kalibračního zařízení nebo přímé měření etalonovým otáčkoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 30 min⁻¹ do 300 min⁻¹ CMC 0,10 %\nod 300 min⁻¹ do 10000 min⁻¹ CMC 0,050 %\nPorównanie z częstościomierzem wzorcowym za pomocą urządzenia kalibracyjnego lub pomiar bezpośredni obrotomierzem wzorcowym","reference":"MK19","norm_bases":["MK19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prędkość obrotowa / obrotomierze, generatory prędkości obrotowej Wzorcowanie – wielkości czasu i częstotliwości Porównanie z częstościomierzem wzorcowym za pomocą urządzenia kalibracyjnego lub pomiar bezpośredni obrotomierzem wzorcowym od 30 min⁻¹ do 300 min⁻¹ CMC 0,10 % od 300 min⁻¹ do 10000 min⁻¹ CMC 0,050 % Otáčky / Otáčkoměry, generátory otáček Kalibrace – veličiny času a frekvence Porovnání s etalonovým čítačem pomocí kalibračního zařízení nebo přímé měření etalonovým otáčkoměrem 30 min⁻¹ až 300 min⁻¹ CMC 0,10 % 300 min⁻¹ až 10000 min⁻¹ CMC 0,050 % MK19 Predkosc obrotowa / obrotomierze, generatory predkosci obrotowej Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z czestosciomierzem wzorcowym za pomoca urzadzenia kalibracyjnego lub pomiar bezposredni obrotomierzem wzorcowym od 30 min⁻¹ do 300 min⁻¹ CMC 0,10 % od 300 min⁻¹ do 10000 min⁻¹ CMC 0,050 % Otacky / Otackomery, generatory otacek Kalibrace – veliciny casu a frekvence Porovnani s etalonovym citacem pomoci kalibracniho zarizeni nebo prime mereni etalonovym otackomerem 30 min⁻¹ az 300 min⁻¹ CMC 0,10 % 300 min⁻¹ az 10000 min⁻¹ CMC 0,050 % MK19","search_en":"Rotational speed / Tachometers, speed generators Calibration – time and frequency quantities Comparison with a standard counter using a calibration device or direct measurement by a standard tachometer 30 min⁻¹ to 300 min⁻¹ CMC 0,10 % 300 min⁻¹ to 10000 min⁻¹ CMC 0,050 % MK19","search_zh":"转速 / 转速表、转速发生器 校准 – 时间和频率量 借助校准装置与标准计数器比较或用标准转速表直接测量 30 min⁻¹ 至 300 min⁻¹ CMC 0,10 % 300 min⁻¹ 至 10000 min⁻¹ CMC 0,050 % MK19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":93,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec13a285eccb3dd1c5d8aedf","lab_id":"6ade8b30ff0682476170810b","country":"CZ","accr_number":"2294","accr_body":"ČIA","row_label":"6","test_object":"Prędkość obrotowa / obrotomierze z wejściem napięciowym","test_object_en":"Rotational speed / Tachometers with voltage input","test_object_zh":"转速 / 带电压输入的转速表","test_object_cs":"Otáčky / Otáčkoměry s napěťovým vstupem","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 5 min⁻¹ do 100000 min⁻¹","cmc":"0,0020 %"}],"parameters_en":[{"name":"","range":"5 min⁻¹ to 100000 min⁻¹","cmc":"0,0020 %"}],"parameters_zh":[{"name":"","range":"5 min⁻¹ 至 100000 min⁻¹","cmc":"0,0020 %"}],"parameters_cs":[{"name":"","range":"5 min⁻¹ až 100000 min⁻¹","cmc":"0,0020 %"}],"technique":"Symulacja elektryczna wzorcowym generatorem częstotliwości","technique_en":"Electrical simulation by a standard frequency generator","technique_zh":"用标准频率发生器进行电模拟","technique_cs":"Elektrická simulace etalonovým generátorem frekvence","techniques":["Symulacja elektryczna wzorcowym generatorem częstotliwości"],"techniques_en":["Electrical simulation by a standard frequency generator"],"techniques_zh":["用标准频率发生器进行电模拟"],"techniques_cs":["Elektrická simulace etalonovým generátorem frekvence"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 5 min⁻¹ do 100000 min⁻¹ CMC 0,0020 %\nSymulacja elektryczna wzorcowym generatorem częstotliwości","reference":"MK19","norm_bases":["MK19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prędkość obrotowa / obrotomierze z wejściem napięciowym Wzorcowanie – wielkości czasu i częstotliwości Symulacja elektryczna wzorcowym generatorem częstotliwości od 5 min⁻¹ do 100000 min⁻¹ CMC 0,0020 % Otáčky / Otáčkoměry s napěťovým vstupem Kalibrace – veličiny času a frekvence Elektrická simulace etalonovým generátorem frekvence 5 min⁻¹ až 100000 min⁻¹ CMC 0,0020 % MK19 Predkosc obrotowa / obrotomierze z wejsciem napieciowym Wzorcowanie – wielkosci czasu i czestotliwosci Symulacja elektryczna wzorcowym generatorem czestotliwosci od 5 min⁻¹ do 100000 min⁻¹ CMC 0,0020 % Otacky / Otackomery s napetovym vstupem Kalibrace – veliciny casu a frekvence Elektricka simulace etalonovym generatorem frekvence 5 min⁻¹ az 100000 min⁻¹ CMC 0,0020 % MK19","search_en":"Rotational speed / Tachometers with voltage input Calibration – time and frequency quantities Electrical simulation by a standard frequency generator 5 min⁻¹ to 100000 min⁻¹ CMC 0,0020 % MK19","search_zh":"转速 / 带电压输入的转速表 校准 – 时间和频率量 用标准频率发生器进行电模拟 5 min⁻¹ 至 100000 min⁻¹ CMC 0,0020 % MK19","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":94,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}