{"lab":{"_id":"6acfffe0ff06824761705e08","country":"CZ","accr_number":"2284","accr_body":"ČIA","address":"Generála Šišky 942, 143 00 Praha 4","categories":["metrology"],"city":"Praha 4","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.4471064,50.0073916]},"map_coord":[50.0073916,14.4471064],"map_geo":"cai-mapa","methods_count":5,"name":"Český hydrometeorologický ústav","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów do pomiaru zanieczyszczenia powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"český hydrometeorologický ústav generála šišky 942, 143 00 praha 4 2284","source_page_url":"https://www.cai.cz/?subjekt=2284-cesky-hydrometeorologicky-ustav","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"06-02-2028","website":"www.chmi.cz","certificate_date":"29.09.2025","certificate_no":"488/2025","certificate_replaces":"53/2023 z 06.02.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów do pomiaru zanieczyszczenia powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of air pollution measuring instruments to the extent as specified in the appendix to this Certificate.","zh":"空气污染测量仪器的校准，范围见本证书附件。","cs":"Kalibrace měřidel pro měření znečištění ovzduší, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące imisji","lab_division_cs":"Kalibrační laboratoř imisí","lab_division_en":"Immission Calibration Laboratory","lab_division_zh":"环境空气质量校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"8d78f09a6999780e9d927ca59acd484651322c212d852b1fd82f0568489caae3","source_pdf_url":"https://www.cai.cz/OA/pdf/488_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/488_2025_EN.pdf"},"methods":[{"_id":"d94fa478c5c6672924d21da5","lab_id":"6acfffe0ff06824761705e08","country":"CZ","accr_number":"2284","accr_body":"ČIA","row_label":"1","test_object":"SO2 w powietrzu","test_object_en":"SO2 in air","test_object_zh":"空气中的SO2","test_object_cs":"SO2 ve vzduchu","methodology":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)","methodology_en":"Calibration – physicochemical quantities (gas concentration)","methodology_zh":"校准 – 物理化学量（气体浓度）","methodology_cs":"Kalibrace – fyzikálně chemické veličiny (koncentrace plynů)","parameters":[{"name":"","range":"od 0 nmol/mol do 80 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"od 80 nmol/mol do 500 nmol/mol","cmc":"1,6 %"}],"parameters_en":[{"name":"","range":"0 nmol/mol to 80 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"80 nmol/mol to 500 nmol/mol","cmc":"1,6 %"}],"parameters_zh":[{"name":"","range":"0 nmol/mol 至 80 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"80 nmol/mol 至 500 nmol/mol","cmc":"1,6 %"}],"parameters_cs":[{"name":"","range":"0 nmol/mol až 80 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"80 nmol/mol až 500 nmol/mol","cmc":"1,6 %"}],"technique":"Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy","technique_en":"Static pressure injection with transfer to a working reference standard","technique_zh":"静态压力注入并传递至工作标准器","technique_cs":"Statická tlaková injektáž s přenosem na pracovní etalon","techniques":["Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy"],"techniques_en":["Static pressure injection with transfer to a working reference standard"],"techniques_zh":["静态压力注入并传递至工作标准器"],"techniques_cs":["Statická tlaková injektáž s přenosem na pracovní etalon"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)\nZakres:\nod 0 nmol/mol do 80 nmol/mol CMC 1,2 nmol/mol\nod 80 nmol/mol do 500 nmol/mol CMC 1,6 %\nStatyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy","reference":"IP-001 + IP-000","norm_bases":["IP-001","IP-000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne (stężenia gazów)","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities (gas concentration)","regulatory_area_zh":"被测量领域的CMC：物理化学量（气体浓度）","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny (koncentrace plynů)","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"SO2 w powietrzu Wzorcowanie – wielkości fizykochemiczne (stężenia gazów) Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy od 0 nmol/mol do 80 nmol/mol CMC 1,2 nmol/mol od 80 nmol/mol do 500 nmol/mol CMC 1,6 % SO2 ve vzduchu Kalibrace – fyzikálně chemické veličiny (koncentrace plynů) Statická tlaková injektáž s přenosem na pracovní etalon 0 nmol/mol až 80 nmol/mol CMC 1,2 nmol/mol 80 nmol/mol až 500 nmol/mol CMC 1,6 % IP-001 + IP-000 SO2 w powietrzu Wzorcowanie – wielkosci fizykochemiczne (stezenia gazow) Statyczny wtrysk cisnieniowy z przeniesieniem na wzorzec roboczy od 0 nmol/mol do 80 nmol/mol CMC 1,2 nmol/mol od 80 nmol/mol do 500 nmol/mol CMC 1,6 % SO2 ve vzduchu Kalibrace – fyzikalne chemicke veliciny (koncentrace plynu) Staticka tlakova injektaz s prenosem na pracovni etalon 0 nmol/mol az 80 nmol/mol CMC 1,2 nmol/mol 80 nmol/mol az 500 nmol/mol CMC 1,6 % IP-001 + IP-000","search_en":"SO2 in air Calibration – physicochemical quantities (gas concentration) Static pressure injection with transfer to a working reference standard 0 nmol/mol to 80 nmol/mol CMC 1,2 nmol/mol 80 nmol/mol to 500 nmol/mol CMC 1,6 % IP-001 + IP-000","search_zh":"空气中的SO2 校准 – 物理化学量（气体浓度） 静态压力注入并传递至工作标准器 0 nmol/mol 至 80 nmol/mol CMC 1,2 nmol/mol 80 nmol/mol 至 500 nmol/mol CMC 1,6 % IP-001 + IP-000","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"066fec6cb9b0235f4487071c","lab_id":"6acfffe0ff06824761705e08","country":"CZ","accr_number":"2284","accr_body":"ČIA","row_label":"2","test_object":"NO – NOX w powietrzu/azocie","test_object_en":"NO – NOX in air/nitrogen","test_object_zh":"空气/氮气中的NO – NOX","test_object_cs":"NO – NOX ve vzduchu/dusíku","methodology":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)","methodology_en":"Calibration – physicochemical quantities (gas concentration)","methodology_zh":"校准 – 物理化学量（气体浓度）","methodology_cs":"Kalibrace – fyzikálně chemické veličiny (koncentrace plynů)","parameters":[{"name":"","range":"od 0 nmol/mol do 100 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"od 100 nmol/mol do 500 nmol/mol","cmc":"1,3 %"}],"parameters_en":[{"name":"","range":"0 nmol/mol to 100 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"100 nmol/mol to 500 nmol/mol","cmc":"1,3 %"}],"parameters_zh":[{"name":"","range":"0 nmol/mol 至 100 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"100 nmol/mol 至 500 nmol/mol","cmc":"1,3 %"}],"parameters_cs":[{"name":"","range":"0 nmol/mol až 100 nmol/mol","cmc":"1,2 nmol/mol"},{"name":"","range":"100 nmol/mol až 500 nmol/mol","cmc":"1,3 %"}],"technique":"Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy","technique_en":"Static pressure injection with transfer to a working reference standard","technique_zh":"静态压力注入并传递至工作标准器","technique_cs":"Statická tlaková injektáž s přenosem na pracovní etalon","techniques":["Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy"],"techniques_en":["Static pressure injection with transfer to a working reference standard"],"techniques_zh":["静态压力注入并传递至工作标准器"],"techniques_cs":["Statická tlaková injektáž s přenosem na pracovní etalon"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)\nZakres:\nod 0 nmol/mol do 100 nmol/mol CMC 1,2 nmol/mol\nod 100 nmol/mol do 500 nmol/mol CMC 1,3 %\nStatyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy","reference":"IP-002 + IP-000","norm_bases":["IP-002","IP-000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne (stężenia gazów)","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities (gas concentration)","regulatory_area_zh":"被测量领域的CMC：物理化学量（气体浓度）","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny (koncentrace plynů)","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"NO – NOX w powietrzu/azocie Wzorcowanie – wielkości fizykochemiczne (stężenia gazów) Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy od 0 nmol/mol do 100 nmol/mol CMC 1,2 nmol/mol od 100 nmol/mol do 500 nmol/mol CMC 1,3 % NO – NOX ve vzduchu/dusíku Kalibrace – fyzikálně chemické veličiny (koncentrace plynů) Statická tlaková injektáž s přenosem na pracovní etalon 0 nmol/mol až 100 nmol/mol CMC 1,2 nmol/mol 100 nmol/mol až 500 nmol/mol CMC 1,3 % IP-002 + IP-000 NO – NOX w powietrzu/azocie Wzorcowanie – wielkosci fizykochemiczne (stezenia gazow) Statyczny wtrysk cisnieniowy z przeniesieniem na wzorzec roboczy od 0 nmol/mol do 100 nmol/mol CMC 1,2 nmol/mol od 100 nmol/mol do 500 nmol/mol CMC 1,3 % NO – NOX ve vzduchu/dusiku Kalibrace – fyzikalne chemicke veliciny (koncentrace plynu) Staticka tlakova injektaz s prenosem na pracovni etalon 0 nmol/mol az 100 nmol/mol CMC 1,2 nmol/mol 100 nmol/mol az 500 nmol/mol CMC 1,3 % IP-002 + IP-000","search_en":"NO – NOX in air/nitrogen Calibration – physicochemical quantities (gas concentration) Static pressure injection with transfer to a working reference standard 0 nmol/mol to 100 nmol/mol CMC 1,2 nmol/mol 100 nmol/mol to 500 nmol/mol CMC 1,3 % IP-002 + IP-000","search_zh":"空气/氮气中的NO – NOX 校准 – 物理化学量（气体浓度） 静态压力注入并传递至工作标准器 0 nmol/mol 至 100 nmol/mol CMC 1,2 nmol/mol 100 nmol/mol 至 500 nmol/mol CMC 1,3 % IP-002 + IP-000","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3bed225c4138cb017716716d","lab_id":"6acfffe0ff06824761705e08","country":"CZ","accr_number":"2284","accr_body":"ČIA","row_label":"3","test_object":"CO w powietrzu/azocie","test_object_en":"CO in air/nitrogen","test_object_zh":"空气/氮气中的CO","test_object_cs":"CO ve vzduchu/dusíku","methodology":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)","methodology_en":"Calibration – physicochemical quantities (gas concentration)","methodology_zh":"校准 – 物理化学量（气体浓度）","methodology_cs":"Kalibrace – fyzikálně chemické veličiny (koncentrace plynů)","parameters":[{"name":"","range":"od 0 nmol/mol do 4500 nmol/mol","cmc":"35 nmol/mol"},{"name":"","range":"od 4500 nmol/mol do 20000 nmol/mol","cmc":"0,84 %"}],"parameters_en":[{"name":"","range":"0 nmol/mol to 4500 nmol/mol","cmc":"35 nmol/mol"},{"name":"","range":"4500 nmol/mol to 20000 nmol/mol","cmc":"0,84 %"}],"parameters_zh":[{"name":"","range":"0 nmol/mol 至 4500 nmol/mol","cmc":"35 nmol/mol"},{"name":"","range":"4500 nmol/mol 至 20000 nmol/mol","cmc":"0,84 %"}],"parameters_cs":[{"name":"","range":"0 nmol/mol až 4500 nmol/mol","cmc":"35 nmol/mol"},{"name":"","range":"4500 nmol/mol až 20000 nmol/mol","cmc":"0,84 %"}],"technique":"Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy","technique_en":"Static pressure injection with transfer to a working reference standard","technique_zh":"静态压力注入并传递至工作标准器","technique_cs":"Statická tlaková injektáž s přenosem na pracovní etalon","techniques":["Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy"],"techniques_en":["Static pressure injection with transfer to a working reference standard"],"techniques_zh":["静态压力注入并传递至工作标准器"],"techniques_cs":["Statická tlaková injektáž s přenosem na pracovní etalon"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)\nZakres:\nod 0 nmol/mol do 4500 nmol/mol CMC 35 nmol/mol\nod 4500 nmol/mol do 20000 nmol/mol CMC 0,84 %\nStatyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy","reference":"IP-003 + IP-000","norm_bases":["IP-003","IP-000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne (stężenia gazów)","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities (gas concentration)","regulatory_area_zh":"被测量领域的CMC：物理化学量（气体浓度）","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny (koncentrace plynů)","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"CO w powietrzu/azocie Wzorcowanie – wielkości fizykochemiczne (stężenia gazów) Statyczny wtrysk ciśnieniowy z przeniesieniem na wzorzec roboczy od 0 nmol/mol do 4500 nmol/mol CMC 35 nmol/mol od 4500 nmol/mol do 20000 nmol/mol CMC 0,84 % CO ve vzduchu/dusíku Kalibrace – fyzikálně chemické veličiny (koncentrace plynů) Statická tlaková injektáž s přenosem na pracovní etalon 0 nmol/mol až 4500 nmol/mol CMC 35 nmol/mol 4500 nmol/mol až 20000 nmol/mol CMC 0,84 % IP-003 + IP-000 CO w powietrzu/azocie Wzorcowanie – wielkosci fizykochemiczne (stezenia gazow) Statyczny wtrysk cisnieniowy z przeniesieniem na wzorzec roboczy od 0 nmol/mol do 4500 nmol/mol CMC 35 nmol/mol od 4500 nmol/mol do 20000 nmol/mol CMC 0,84 % CO ve vzduchu/dusiku Kalibrace – fyzikalne chemicke veliciny (koncentrace plynu) Staticka tlakova injektaz s prenosem na pracovni etalon 0 nmol/mol az 4500 nmol/mol CMC 35 nmol/mol 4500 nmol/mol az 20000 nmol/mol CMC 0,84 % IP-003 + IP-000","search_en":"CO in air/nitrogen Calibration – physicochemical quantities (gas concentration) Static pressure injection with transfer to a working reference standard 0 nmol/mol to 4500 nmol/mol CMC 35 nmol/mol 4500 nmol/mol to 20000 nmol/mol CMC 0,84 % IP-003 + IP-000","search_zh":"空气/氮气中的CO 校准 – 物理化学量（气体浓度） 静态压力注入并传递至工作标准器 0 nmol/mol 至 4500 nmol/mol CMC 35 nmol/mol 4500 nmol/mol 至 20000 nmol/mol CMC 0,84 % IP-003 + IP-000","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c50e2f19a1b1ebe7a91cea5b","lab_id":"6acfffe0ff06824761705e08","country":"CZ","accr_number":"2284","accr_body":"ČIA","row_label":"4","test_object":"O3 w powietrzu","test_object_en":"O3 in air","test_object_zh":"空气中的O3","test_object_cs":"O3 ve vzduchu","methodology":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)","methodology_en":"Calibration – physicochemical quantities (gas concentration)","methodology_zh":"校准 – 物理化学量（气体浓度）","methodology_cs":"Kalibrace – fyzikálně chemické veličiny (koncentrace plynů)","parameters":[{"name":"","range":"od 0 nmol/mol do 50 nmol/mol","cmc":"1,1 nmol/mol"},{"name":"","range":"od 50 nmol/mol do 1000 nmol/mol","cmc":"0,93 %"}],"parameters_en":[{"name":"","range":"0 nmol/mol to 50 nmol/mol","cmc":"1,1 nmol/mol"},{"name":"","range":"50 nmol/mol to 1000 nmol/mol","cmc":"0,93 %"}],"parameters_zh":[{"name":"","range":"0 nmol/mol 至 50 nmol/mol","cmc":"1,1 nmol/mol"},{"name":"","range":"50 nmol/mol 至 1000 nmol/mol","cmc":"0,93 %"}],"parameters_cs":[{"name":"","range":"0 nmol/mol až 50 nmol/mol","cmc":"1,1 nmol/mol"},{"name":"","range":"50 nmol/mol až 1000 nmol/mol","cmc":"0,93 %"}],"technique":"Spójność z wzorcem odniesienia O3","technique_en":"Reference to an O3 reference standard","technique_zh":"溯源至O3参考标准器","technique_cs":"Navázání na referenční etalon O3","techniques":["Spójność z wzorcem odniesienia O3"],"techniques_en":["Reference to an O3 reference standard"],"techniques_zh":["溯源至O3参考标准器"],"techniques_cs":["Navázání na referenční etalon O3"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)\nZakres:\nod 0 nmol/mol do 50 nmol/mol CMC 1,1 nmol/mol\nod 50 nmol/mol do 1000 nmol/mol CMC 0,93 %\nSpójność z wzorcem odniesienia O3","reference":"IP-004 + IP-000","norm_bases":["IP-004","IP-000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne (stężenia gazów)","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities (gas concentration)","regulatory_area_zh":"被测量领域的CMC：物理化学量（气体浓度）","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny (koncentrace plynů)","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"O3 w powietrzu Wzorcowanie – wielkości fizykochemiczne (stężenia gazów) Spójność z wzorcem odniesienia O3 od 0 nmol/mol do 50 nmol/mol CMC 1,1 nmol/mol od 50 nmol/mol do 1000 nmol/mol CMC 0,93 % O3 ve vzduchu Kalibrace – fyzikálně chemické veličiny (koncentrace plynů) Navázání na referenční etalon O3 0 nmol/mol až 50 nmol/mol CMC 1,1 nmol/mol 50 nmol/mol až 1000 nmol/mol CMC 0,93 % IP-004 + IP-000 O3 w powietrzu Wzorcowanie – wielkosci fizykochemiczne (stezenia gazow) Spojnosc z wzorcem odniesienia O3 od 0 nmol/mol do 50 nmol/mol CMC 1,1 nmol/mol od 50 nmol/mol do 1000 nmol/mol CMC 0,93 % O3 ve vzduchu Kalibrace – fyzikalne chemicke veliciny (koncentrace plynu) Navazani na referencni etalon O3 0 nmol/mol az 50 nmol/mol CMC 1,1 nmol/mol 50 nmol/mol az 1000 nmol/mol CMC 0,93 % IP-004 + IP-000","search_en":"O3 in air Calibration – physicochemical quantities (gas concentration) Reference to an O3 reference standard 0 nmol/mol to 50 nmol/mol CMC 1,1 nmol/mol 50 nmol/mol to 1000 nmol/mol CMC 0,93 % IP-004 + IP-000","search_zh":"空气中的O3 校准 – 物理化学量（气体浓度） 溯源至O3参考标准器 0 nmol/mol 至 50 nmol/mol CMC 1,1 nmol/mol 50 nmol/mol 至 1000 nmol/mol CMC 0,93 % IP-004 + IP-000","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41ab9772b3618545749db81f","lab_id":"6acfffe0ff06824761705e08","country":"CZ","accr_number":"2284","accr_body":"ČIA","row_label":"5","test_object":"BTX w powietrzu/azocie","test_object_en":"BTX in air/nitrogen","test_object_zh":"空气/氮气中的BTX","test_object_cs":"BTX ve vzduchu/dusíku","methodology":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)","methodology_en":"Calibration – physicochemical quantities (gas concentration)","methodology_zh":"校准 – 物理化学量（气体浓度）","methodology_cs":"Kalibrace – fyzikálně chemické veličiny (koncentrace plynů)","parameters":[{"name":"","range":"od 0 nmol/mol do 1 nmol/mol","cmc":"0,035 nmol/mol"},{"name":"","range":"od 1 nmol/mol do 12 nmol/mol","cmc":"3,3 %"}],"parameters_en":[{"name":"","range":"0 nmol/mol to 1 nmol/mol","cmc":"0,035 nmol/mol"},{"name":"","range":"1 nmol/mol to 12 nmol/mol","cmc":"3,3 %"}],"parameters_zh":[{"name":"","range":"0 nmol/mol 至 1 nmol/mol","cmc":"0,035 nmol/mol"},{"name":"","range":"1 nmol/mol 至 12 nmol/mol","cmc":"3,3 %"}],"parameters_cs":[{"name":"","range":"0 nmol/mol až 1 nmol/mol","cmc":"0,035 nmol/mol"},{"name":"","range":"1 nmol/mol až 12 nmol/mol","cmc":"3,3 %"}],"technique":"Bezpośrednie porównanie z pierwotnym materiałem odniesienia BTX","technique_en":"Direct comparison with a primary BTX reference material","technique_zh":"与BTX原级标准物质直接比较","technique_cs":"Přímé porovnání s primárním referenčním materiálem BTX","techniques":["Bezpośrednie porównanie z pierwotnym materiałem odniesienia BTX"],"techniques_en":["Direct comparison with a primary BTX reference material"],"techniques_zh":["与BTX原级标准物质直接比较"],"techniques_cs":["Přímé porovnání s primárním referenčním materiálem BTX"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne (stężenia gazów)\nZakres:\nod 0 nmol/mol do 1 nmol/mol CMC 0,035 nmol/mol\nod 1 nmol/mol do 12 nmol/mol CMC 3,3 %\nBezpośrednie porównanie z pierwotnym materiałem odniesienia BTX","reference":"IP-005 + IP-000","norm_bases":["IP-005","IP-000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne (stężenia gazów)","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities (gas concentration)","regulatory_area_zh":"被测量领域的CMC：物理化学量（气体浓度）","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny (koncentrace plynů)","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"BTX w powietrzu/azocie Wzorcowanie – wielkości fizykochemiczne (stężenia gazów) Bezpośrednie porównanie z pierwotnym materiałem odniesienia BTX od 0 nmol/mol do 1 nmol/mol CMC 0,035 nmol/mol od 1 nmol/mol do 12 nmol/mol CMC 3,3 % BTX ve vzduchu/dusíku Kalibrace – fyzikálně chemické veličiny (koncentrace plynů) Přímé porovnání s primárním referenčním materiálem BTX 0 nmol/mol až 1 nmol/mol CMC 0,035 nmol/mol 1 nmol/mol až 12 nmol/mol CMC 3,3 % IP-005 + IP-000 BTX w powietrzu/azocie Wzorcowanie – wielkosci fizykochemiczne (stezenia gazow) Bezposrednie porownanie z pierwotnym materialem odniesienia BTX od 0 nmol/mol do 1 nmol/mol CMC 0,035 nmol/mol od 1 nmol/mol do 12 nmol/mol CMC 3,3 % BTX ve vzduchu/dusiku Kalibrace – fyzikalne chemicke veliciny (koncentrace plynu) Prime porovnani s primarnim referencnim materialem BTX 0 nmol/mol az 1 nmol/mol CMC 0,035 nmol/mol 1 nmol/mol az 12 nmol/mol CMC 3,3 % IP-005 + IP-000","search_en":"BTX in air/nitrogen Calibration – physicochemical quantities (gas concentration) Direct comparison with a primary BTX reference material 0 nmol/mol to 1 nmol/mol CMC 0,035 nmol/mol 1 nmol/mol to 12 nmol/mol CMC 3,3 % IP-005 + IP-000","search_zh":"空气/氮气中的BTX 校准 – 物理化学量（气体浓度） 与BTX原级标准物质直接比较 0 nmol/mol 至 1 nmol/mol CMC 0,035 nmol/mol 1 nmol/mol 至 12 nmol/mol CMC 3,3 % IP-005 + IP-000","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}