{"lab":{"_id":"6ade8b2eff06824761708105","accr_number":"2281","country":"CZ","accr_body":"ČIA","address":"Štěpánkova 6, 644 00 Brno","categories":["metrology"],"city":"Brno","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.6237562,49.2521441]},"map_coord":[49.2521441,16.6237562],"map_geo":"cai-mapa","methods_count":9,"name":"LAB-MET s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: objętość, prędkość obrotowa, temperatura i wilgotność.","search_text":"lab-met s.r.o. štěpánkova 6, 644 00 brno 2281","source_page_url":"https://www.cai.cz/?subjekt=2281-lab-met-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"01-11-2027","website":"www.labmet.cz","certificate_date":"01.11.2022","certificate_no":"519/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: objętość, prędkość obrotowa, temperatura i wilgotność.","en":"Calibration in the fields of volume, rotational speed, temperature and humidity.","zh":"体积、转速、温度和湿度领域的校准。","cs":"Kalibrace v oborech objem, otáčky, teplota a vlhkost."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Przy wzorcowaniu poza stałą siedzibą podawana niepewność wzorcowania może ulec zmianie.","en":"When calibrating outside the permanent premises, the stated calibration uncertainty may be affected.","zh":"在固定场所以外进行校准时，所述校准不确定度可能受到影响。","cs":"Při kalibraci mimo stálé prostory je možné ovlivnění udávané nejistoty kalibrace."}],"source_lang":"cs","source_pdf_sha256":"edb8858a7704c851da08cd5cf8abb90316a1682d3879ccea5c5e36152b820718","source_pdf_url":"https://www.cai.cz/OA/pdf/P519_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"3fa7d20d42aa588b6bde635a","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"1","test_object":"Pipety tłokowe","test_object_en":"Piston pipettes","test_object_zh":"活塞式移液器","test_object_cs":"Pístové pipety","methodology":"Wzorcowanie – objętość, przepływ","methodology_en":"Calibration – volume, flow","methodology_zh":"校准 – 体积、流量","methodology_cs":"Kalibrace – objem, průtok","parameters":[{"name":"","range":"od 0,5 µl do 10000 µl","cmc":"0,12 % + 0,02 µl"}],"parameters_en":[{"name":"","range":"0,5 µl to 10000 µl","cmc":"0,12 % + 0,02 µl"}],"parameters_zh":[{"name":"","range":"0,5 µl 至 10000 µl","cmc":"0,12 % + 0,02 µl"}],"parameters_cs":[{"name":"","range":"0,5 µl až 10000 µl","cmc":"0,12 % + 0,02 µl"}],"technique":"Grawimetrycznie","technique_en":"Gravimetrically","technique_zh":"重量法","technique_cs":"Gravimetricky","techniques":["Grawimetrycznie"],"techniques_en":["Gravimetrically"],"techniques_zh":["重量法"],"techniques_cs":["Gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość, przepływ\nod 0,5 µl do 10000 µl CMC 0,12 % + 0,02 µl\nGrawimetrycznie","reference":"MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19)","norm_bases":["MKO 3/001/98","ČSN EN ISO 8655-6","Euramet cg-19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość, przepływ","regulatory_area_en":"CMC for the field of measured quantity: Volume, flow","regulatory_area_zh":"被测量领域的CMC：体积、流量","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem, průtok","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pipety tłokowe Wzorcowanie – objętość, przepływ Grawimetrycznie od 0,5 µl do 10000 µl CMC 0,12 % + 0,02 µl Pístové pipety Kalibrace – objem, průtok Gravimetricky 0,5 µl až 10000 µl CMC 0,12 % + 0,02 µl MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19) Pipety tlokowe Wzorcowanie – objetosc, przeplyw Grawimetrycznie od 0,5 µl do 10000 µl CMC 0,12 % + 0,02 µl Pistove pipety Kalibrace – objem, prutok Gravimetricky 0,5 µl az 10000 µl CMC 0,12 % + 0,02 µl MKO 3/001/98 (CSN EN ISO 8655-6 Euramet cg-19)","search_en":"Piston pipettes Calibration – volume, flow Gravimetrically 0,5 µl to 10000 µl CMC 0,12 % + 0,02 µl MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19)","search_zh":"活塞式移液器 校准 – 体积、流量 重量法 0,5 µl 至 10000 µl CMC 0,12 % + 0,02 µl MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26540c82a722744ec7ab4d09","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"2","test_object":"Pozostałe tłokowe przyrządy pomiarowe","test_object_en":"Other piston-operated measuring instruments","test_object_zh":"其他活塞式量器","test_object_cs":"Ostatní pístová měřidla","methodology":"Wzorcowanie – objętość, przepływ","methodology_en":"Calibration – volume, flow","methodology_zh":"校准 – 体积、流量","methodology_cs":"Kalibrace – objem, průtok","parameters":[{"name":"","range":"od 100 µl do 50000 µl","cmc":"0,05 %"}],"parameters_en":[{"name":"","range":"100 µl to 50000 µl","cmc":"0,05 %"}],"parameters_zh":[{"name":"","range":"100 µl 至 50000 µl","cmc":"0,05 %"}],"parameters_cs":[{"name":"","range":"100 µl až 50000 µl","cmc":"0,05 %"}],"technique":"Grawimetrycznie","technique_en":"Gravimetrically","technique_zh":"重量法","technique_cs":"Gravimetricky","techniques":["Grawimetrycznie"],"techniques_en":["Gravimetrically"],"techniques_zh":["重量法"],"techniques_cs":["Gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – objętość, przepływ\nod 100 µl do 50000 µl CMC 0,05 %\nGrawimetrycznie","reference":"MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19)","norm_bases":["MKO 3/001/98","ČSN EN ISO 8655-6","Euramet cg-19"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: objętość, przepływ","regulatory_area_en":"CMC for the field of measured quantity: Volume, flow","regulatory_area_zh":"被测量领域的CMC：体积、流量","regulatory_area_cs":"CMC pro obor měřené veličiny: Objem, průtok","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pozostałe tłokowe przyrządy pomiarowe Wzorcowanie – objętość, przepływ Grawimetrycznie od 100 µl do 50000 µl CMC 0,05 % Ostatní pístová měřidla Kalibrace – objem, průtok Gravimetricky 100 µl až 50000 µl CMC 0,05 % MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19) Pozostale tlokowe przyrzady pomiarowe Wzorcowanie – objetosc, przeplyw Grawimetrycznie od 100 µl do 50000 µl CMC 0,05 % Ostatni pistova meridla Kalibrace – objem, prutok Gravimetricky 100 µl az 50000 µl CMC 0,05 % MKO 3/001/98 (CSN EN ISO 8655-6 Euramet cg-19)","search_en":"Other piston-operated measuring instruments Calibration – volume, flow Gravimetrically 100 µl to 50000 µl CMC 0,05 % MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19)","search_zh":"其他活塞式量器 校准 – 体积、流量 重量法 100 µl 至 50000 µl CMC 0,05 % MKO 3/001/98 (ČSN EN ISO 8655-6 Euramet cg-19)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7fb1f94fea68cc0dd0fbfd48","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru prędkości obrotowej","test_object_en":"Rotational speed meters","test_object_zh":"转速测量仪","test_object_cs":"Měřidla otáček","methodology":"Wzorcowanie – ruch mechaniczny - prędkość obrotowa","methodology_en":"Calibration – mechanical motion - rotational speed","methodology_zh":"校准 – 机械运动 - 转速","methodology_cs":"Kalibrace – mechanický pohyb - otáčky","parameters":[{"name":"","range":"od 1,0 min⁻¹ do 600,0 min⁻¹","cmc":"0,2 min⁻¹"},{"name":"","range":"od 600,1 min⁻¹ do 999,9 min⁻¹","cmc":"1,2 min⁻¹"},{"name":"","range":"od 1000 min⁻¹ do 30000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"od 30001 min⁻¹ do 99999 min⁻¹","cmc":"5 min⁻¹"}],"parameters_en":[{"name":"","range":"1,0 min⁻¹ to 600,0 min⁻¹","cmc":"0,2 min⁻¹"},{"name":"","range":"600,1 min⁻¹ to 999,9 min⁻¹","cmc":"1,2 min⁻¹"},{"name":"","range":"1000 min⁻¹ to 30000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"30001 min⁻¹ to 99999 min⁻¹","cmc":"5 min⁻¹"}],"parameters_zh":[{"name":"","range":"1,0 min⁻¹ 至 600,0 min⁻¹","cmc":"0,2 min⁻¹"},{"name":"","range":"600,1 min⁻¹ 至 999,9 min⁻¹","cmc":"1,2 min⁻¹"},{"name":"","range":"1000 min⁻¹ 至 30000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"30001 min⁻¹ 至 99999 min⁻¹","cmc":"5 min⁻¹"}],"parameters_cs":[{"name":"","range":"1,0 min⁻¹ až 600,0 min⁻¹","cmc":"0,2 min⁻¹"},{"name":"","range":"600,1 min⁻¹ až 999,9 min⁻¹","cmc":"1,2 min⁻¹"},{"name":"","range":"1000 min⁻¹ až 30000 min⁻¹","cmc":"2 min⁻¹"},{"name":"","range":"30001 min⁻¹ až 99999 min⁻¹","cmc":"5 min⁻¹"}],"technique":"Porównanie z wzorcowym obrotomierzem metodą bezdotykową","technique_en":"Comparison with a standard tachometer by the non-contact method","technique_zh":"用非接触法与标准转速表比较","technique_cs":"Porovnání s etalonovým otáčkoměrem bezkontaktní metodou","techniques":["Porównanie z wzorcowym obrotomierzem metodą bezdotykową"],"techniques_en":["Comparison with a standard tachometer by the non-contact method"],"techniques_zh":["用非接触法与标准转速表比较"],"techniques_cs":["Porovnání s etalonovým otáčkoměrem bezkontaktní metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny - prędkość obrotowa\nZakres:\nod 1,0 min⁻¹ do 600,0 min⁻¹ CMC 0,2 min⁻¹\nod 600,1 min⁻¹ do 999,9 min⁻¹ CMC 1,2 min⁻¹\nod 1000 min⁻¹ do 30000 min⁻¹ CMC 2 min⁻¹\nod 30001 min⁻¹ do 99999 min⁻¹ CMC 5 min⁻¹\nPorównanie z wzorcowym obrotomierzem metodą bezdotykową","reference":"MKOT 3/027/12","norm_bases":["MKOT 3/027/12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny - prędkość obrotowa","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion - rotational speed","regulatory_area_zh":"被测量领域的CMC：机械运动 - 转速","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb - otáčky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru prędkości obrotowej Wzorcowanie – ruch mechaniczny - prędkość obrotowa Porównanie z wzorcowym obrotomierzem metodą bezdotykową od 1,0 min⁻¹ do 600,0 min⁻¹ CMC 0,2 min⁻¹ od 600,1 min⁻¹ do 999,9 min⁻¹ CMC 1,2 min⁻¹ od 1000 min⁻¹ do 30000 min⁻¹ CMC 2 min⁻¹ od 30001 min⁻¹ do 99999 min⁻¹ CMC 5 min⁻¹ Měřidla otáček Kalibrace – mechanický pohyb - otáčky Porovnání s etalonovým otáčkoměrem bezkontaktní metodou 1,0 min⁻¹ až 600,0 min⁻¹ CMC 0,2 min⁻¹ 600,1 min⁻¹ až 999,9 min⁻¹ CMC 1,2 min⁻¹ 1000 min⁻¹ až 30000 min⁻¹ CMC 2 min⁻¹ 30001 min⁻¹ až 99999 min⁻¹ CMC 5 min⁻¹ MKOT 3/027/12 Przyrzady do pomiaru predkosci obrotowej Wzorcowanie – ruch mechaniczny - predkosc obrotowa Porownanie z wzorcowym obrotomierzem metoda bezdotykowa od 1,0 min⁻¹ do 600,0 min⁻¹ CMC 0,2 min⁻¹ od 600,1 min⁻¹ do 999,9 min⁻¹ CMC 1,2 min⁻¹ od 1000 min⁻¹ do 30000 min⁻¹ CMC 2 min⁻¹ od 30001 min⁻¹ do 99999 min⁻¹ CMC 5 min⁻¹ Meridla otacek Kalibrace – mechanicky pohyb - otacky Porovnani s etalonovym otackomerem bezkontaktni metodou 1,0 min⁻¹ az 600,0 min⁻¹ CMC 0,2 min⁻¹ 600,1 min⁻¹ az 999,9 min⁻¹ CMC 1,2 min⁻¹ 1000 min⁻¹ az 30000 min⁻¹ CMC 2 min⁻¹ 30001 min⁻¹ az 99999 min⁻¹ CMC 5 min⁻¹ MKOT 3/027/12","search_en":"Rotational speed meters Calibration – mechanical motion - rotational speed Comparison with a standard tachometer by the non-contact method 1,0 min⁻¹ to 600,0 min⁻¹ CMC 0,2 min⁻¹ 600,1 min⁻¹ to 999,9 min⁻¹ CMC 1,2 min⁻¹ 1000 min⁻¹ to 30000 min⁻¹ CMC 2 min⁻¹ 30001 min⁻¹ to 99999 min⁻¹ CMC 5 min⁻¹ MKOT 3/027/12","search_zh":"转速测量仪 校准 – 机械运动 - 转速 用非接触法与标准转速表比较 1,0 min⁻¹ 至 600,0 min⁻¹ CMC 0,2 min⁻¹ 600,1 min⁻¹ 至 999,9 min⁻¹ CMC 1,2 min⁻¹ 1000 min⁻¹ 至 30000 min⁻¹ CMC 2 min⁻¹ 30001 min⁻¹ 至 99999 min⁻¹ CMC 5 min⁻¹ MKOT 3/027/12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b10fd62b0e963ece7ee8991","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"1","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 140 °C","cmc":"0,08 °C"},{"name":"","range":"od 140 °C do 250 °C","cmc":"0,10 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 140 °C","cmc":"0,08 °C"},{"name":"","range":"140 °C to 250 °C","cmc":"0,10 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 140 °C","cmc":"0,08 °C"},{"name":"","range":"140 °C 至 250 °C","cmc":"0,10 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 140 °C","cmc":"0,08 °C"},{"name":"","range":"140 °C až 250 °C","cmc":"0,10 °C"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 140 °C CMC 0,08 °C\nod 140 °C do 250 °C CMC 0,10 °C\nPorównanie z wzorcem","reference":"MKST 3/002/98","norm_bases":["MKST 3/002/98"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z wzorcem od -30 °C do 140 °C CMC 0,08 °C od 140 °C do 250 °C CMC 0,10 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonem -30 °C až 140 °C CMC 0,08 °C 140 °C až 250 °C CMC 0,10 °C MKST 3/002/98 Termometry szklane Wzorcowanie – temperatura Porownanie z wzorcem od -30 °C do 140 °C CMC 0,08 °C od 140 °C do 250 °C CMC 0,10 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonem -30 °C az 140 °C CMC 0,08 °C 140 °C az 250 °C CMC 0,10 °C MKST 3/002/98","search_en":"Glass thermometers Calibration – temperature Comparison with a standard -30 °C to 140 °C CMC 0,08 °C 140 °C to 250 °C CMC 0,10 °C MKST 3/002/98","search_zh":"玻璃温度计 校准 – 温度 与标准器比较 -30 °C 至 140 °C CMC 0,08 °C 140 °C 至 250 °C CMC 0,10 °C MKST 3/002/98","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5500ea27c945ffa0de7935ac","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"2","test_object":"Termometry elektroniczne i bezpośrednio wskazujące","test_object_en":"Electronic and direct-reading thermometers","test_object_zh":"电子温度计和直读式温度计","test_object_cs":"Teploměry elektronické a přímo ukazující","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"od 0 °C do 140 °C","cmc":"0,08 °C"},{"name":"","range":"od 140 °C do 250 °C","cmc":"0,09 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C to 140 °C","cmc":"0,08 °C"},{"name":"","range":"140 °C to 250 °C","cmc":"0,09 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C 至 140 °C","cmc":"0,08 °C"},{"name":"","range":"140 °C 至 250 °C","cmc":"0,09 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C až 140 °C","cmc":"0,08 °C"},{"name":"","range":"140 °C až 250 °C","cmc":"0,09 °C"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 0 °C CMC 0,08 °C\n0 °C CMC 0,05 °C\nod 0 °C do 140 °C CMC 0,08 °C\nod 140 °C do 250 °C CMC 0,09 °C\nPorównanie z wzorcem","reference":"MKET 3/003/98","norm_bases":["MKET 3/003/98"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne i bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcem od -30 °C do 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C od 0 °C do 140 °C CMC 0,08 °C od 140 °C do 250 °C CMC 0,09 °C Teploměry elektronické a přímo ukazující Kalibrace – teplota Porovnání s etalonem -30 °C až 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C až 140 °C CMC 0,08 °C 140 °C až 250 °C CMC 0,09 °C MKET 3/003/98 Termometry elektroniczne i bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcem od -30 °C do 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C od 0 °C do 140 °C CMC 0,08 °C od 140 °C do 250 °C CMC 0,09 °C Teplomery elektronicke a primo ukazujici Kalibrace – teplota Porovnani s etalonem -30 °C az 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C az 140 °C CMC 0,08 °C 140 °C az 250 °C CMC 0,09 °C MKET 3/003/98","search_en":"Electronic and direct-reading thermometers Calibration – temperature Comparison with a standard -30 °C to 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C to 140 °C CMC 0,08 °C 140 °C to 250 °C CMC 0,09 °C MKET 3/003/98","search_zh":"电子温度计和直读式温度计 校准 – 温度 与标准器比较 -30 °C 至 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C 至 140 °C CMC 0,08 °C 140 °C 至 250 °C CMC 0,09 °C MKET 3/003/98","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"92634014c6d2784855f4547a","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"3","test_object":"Termometry elektroniczne i tarczowe, wbudowane w urządzenia","test_object_en":"Electronic and dial thermometers built into equipment","test_object_zh":"内置于设备中的电子温度计和指针式温度计","test_object_cs":"Teploměry elektronické a číselníkové, zabudované v zařízeních","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -50 °C","cmc":"0,2 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"od 0 °C do 300 °C","cmc":"0,1 °C"},{"name":"","range":"od 300 °C do 500 °C","cmc":"1,5 °C"},{"name":"","range":"od 500 °C do 800 °C","cmc":"1,8 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"2,0 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"2,1 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -50 °C","cmc":"0,2 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C to 300 °C","cmc":"0,1 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"1,5 °C"},{"name":"","range":"500 °C to 800 °C","cmc":"1,8 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"2,0 °C"},{"name":"","range":"1000 °C to 1200 °C","cmc":"2,1 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -50 °C","cmc":"0,2 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C 至 300 °C","cmc":"0,1 °C"},{"name":"","range":"300 °C 至 500 °C","cmc":"1,5 °C"},{"name":"","range":"500 °C 至 800 °C","cmc":"1,8 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"2,0 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"2,1 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -50 °C","cmc":"0,2 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C až 300 °C","cmc":"0,1 °C"},{"name":"","range":"300 °C až 500 °C","cmc":"1,5 °C"},{"name":"","range":"500 °C až 800 °C","cmc":"1,8 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"2,0 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"2,1 °C"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -50 °C CMC 0,2 °C\n0 °C CMC 0,07 °C\nod 0 °C do 300 °C CMC 0,1 °C\nod 300 °C do 500 °C CMC 1,5 °C\nod 500 °C do 800 °C CMC 1,8 °C\nod 800 °C do 1000 °C CMC 2,0 °C\nod 1000 °C do 1200 °C CMC 2,1 °C\nPorównanie z wzorcem","reference":"KEXT 3/030/00","norm_bases":["KEXT 3/030/00"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne i tarczowe, wbudowane w urządzenia Wzorcowanie – temperatura Porównanie z wzorcem od -80 °C do -50 °C CMC 0,2 °C 0 °C CMC 0,07 °C od 0 °C do 300 °C CMC 0,1 °C od 300 °C do 500 °C CMC 1,5 °C od 500 °C do 800 °C CMC 1,8 °C od 800 °C do 1000 °C CMC 2,0 °C od 1000 °C do 1200 °C CMC 2,1 °C Teploměry elektronické a číselníkové, zabudované v zařízeních Kalibrace – teplota Porovnání s etalonem -80 °C až -50 °C CMC 0,2 °C 0 °C CMC 0,07 °C 0 °C až 300 °C CMC 0,1 °C 300 °C až 500 °C CMC 1,5 °C 500 °C až 800 °C CMC 1,8 °C 800 °C až 1000 °C CMC 2,0 °C 1000 °C až 1200 °C CMC 2,1 °C KEXT 3/030/00 Termometry elektroniczne i tarczowe, wbudowane w urzadzenia Wzorcowanie – temperatura Porownanie z wzorcem od -80 °C do -50 °C CMC 0,2 °C 0 °C CMC 0,07 °C od 0 °C do 300 °C CMC 0,1 °C od 300 °C do 500 °C CMC 1,5 °C od 500 °C do 800 °C CMC 1,8 °C od 800 °C do 1000 °C CMC 2,0 °C od 1000 °C do 1200 °C CMC 2,1 °C Teplomery elektronicke a ciselnikove, zabudovane v zarizenich Kalibrace – teplota Porovnani s etalonem -80 °C az -50 °C CMC 0,2 °C 0 °C CMC 0,07 °C 0 °C az 300 °C CMC 0,1 °C 300 °C az 500 °C CMC 1,5 °C 500 °C az 800 °C CMC 1,8 °C 800 °C az 1000 °C CMC 2,0 °C 1000 °C az 1200 °C CMC 2,1 °C KEXT 3/030/00","search_en":"Electronic and dial thermometers built into equipment Calibration – temperature Comparison with a standard -80 °C to -50 °C CMC 0,2 °C 0 °C CMC 0,07 °C 0 °C to 300 °C CMC 0,1 °C 300 °C to 500 °C CMC 1,5 °C 500 °C to 800 °C CMC 1,8 °C 800 °C to 1000 °C CMC 2,0 °C 1000 °C to 1200 °C CMC 2,1 °C KEXT 3/030/00","search_zh":"内置于设备中的电子温度计和指针式温度计 校准 – 温度 与标准器比较 -80 °C 至 -50 °C CMC 0,2 °C 0 °C CMC 0,07 °C 0 °C 至 300 °C CMC 0,1 °C 300 °C 至 500 °C CMC 1,5 °C 500 °C 至 800 °C CMC 1,8 °C 800 °C 至 1000 °C CMC 2,0 °C 1000 °C 至 1200 °C CMC 2,1 °C KEXT 3/030/00","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ea0fc20ccb43a29934206636","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"4","test_object":"Sterylizatory na gorące powietrze i parowe, suszarki, piece, termostaty, urządzenia mrożące i chłodzące, łaźnie cieczowe, wirówki chłodzone, komory klimatyczne (tylko część temperaturowa do objętości 2000 dm³), kotły homogenizacyjne","test_object_en":"Hot-air and steam sterilizers, drying ovens, furnaces, thermostats, freezing and cooling equipment, liquid baths, refrigerated centrifuges, climatic chambers (temperature part only, up to a volume of 2000 dm³), homogenization boilers","test_object_zh":"热空气和蒸汽灭菌器、干燥箱、炉、恒温箱、冷冻和冷却设备、液体槽、冷冻离心机、气候箱（仅温度部分，容积至 2000 dm³）、均质锅","test_object_cs":"Sterilizátory horkovzdušné a parní, sušárny, pece, termostaty, mrazící a chladící zařízení, kapalinové lázně, chlazené odstředivky klimatické komory (jen teplotní část do objemu 2000 dm³), homogenizační kotle","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -50 °C","cmc":"0,2 °C"},{"name":"","range":"od -50 °C do -50 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"od 0 °C do 300 °C","cmc":"0,1 °C"},{"name":"","range":"od 300 °C do 500 °C","cmc":"1,5 °C"},{"name":"","range":"od 500 °C do 800 °C","cmc":"1,8 °C"},{"name":"","range":"od 800 °C do 1000 °C","cmc":"2,0 °C"},{"name":"","range":"od 1000 °C do 1200 °C","cmc":"2,1 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -50 °C","cmc":"0,2 °C"},{"name":"","range":"-50 °C to -50 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C to 300 °C","cmc":"0,1 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"1,5 °C"},{"name":"","range":"500 °C to 800 °C","cmc":"1,8 °C"},{"name":"","range":"800 °C to 1000 °C","cmc":"2,0 °C"},{"name":"","range":"1000 °C to 1200 °C","cmc":"2,1 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -50 °C","cmc":"0,2 °C"},{"name":"","range":"-50 °C 至 -50 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C 至 300 °C","cmc":"0,1 °C"},{"name":"","range":"300 °C 至 500 °C","cmc":"1,5 °C"},{"name":"","range":"500 °C 至 800 °C","cmc":"1,8 °C"},{"name":"","range":"800 °C 至 1000 °C","cmc":"2,0 °C"},{"name":"","range":"1000 °C 至 1200 °C","cmc":"2,1 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -50 °C","cmc":"0,2 °C"},{"name":"","range":"-50 °C až -50 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C až 300 °C","cmc":"0,1 °C"},{"name":"","range":"300 °C až 500 °C","cmc":"1,5 °C"},{"name":"","range":"500 °C až 800 °C","cmc":"1,8 °C"},{"name":"","range":"800 °C až 1000 °C","cmc":"2,0 °C"},{"name":"","range":"1000 °C až 1200 °C","cmc":"2,1 °C"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -50 °C CMC 0,2 °C\nod -50 °C do -50 °C CMC 0,1 °C\n0 °C CMC 0,07 °C\nod 0 °C do 300 °C CMC 0,1 °C\nod 300 °C do 500 °C CMC 1,5 °C\nod 500 °C do 800 °C CMC 1,8 °C\nod 800 °C do 1000 °C CMC 2,0 °C\nod 1000 °C do 1200 °C CMC 2,1 °C\nPorównanie z wzorcem","reference":"KEXT 3/036/03","norm_bases":["KEXT 3/036/03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory na gorące powietrze i parowe, suszarki, piece, termostaty, urządzenia mrożące i chłodzące, łaźnie cieczowe, wirówki chłodzone, komory klimatyczne (tylko część temperaturowa do objętości 2000 dm³), kotły homogenizacyjne Wzorcowanie – temperatura Porównanie z wzorcem od -80 °C do -50 °C CMC 0,2 °C od -50 °C do -50 °C CMC 0,1 °C 0 °C CMC 0,07 °C od 0 °C do 300 °C CMC 0,1 °C od 300 °C do 500 °C CMC 1,5 °C od 500 °C do 800 °C CMC 1,8 °C od 800 °C do 1000 °C CMC 2,0 °C od 1000 °C do 1200 °C CMC 2,1 °C Sterilizátory horkovzdušné a parní, sušárny, pece, termostaty, mrazící a chladící zařízení, kapalinové lázně, chlazené odstředivky klimatické komory (jen teplotní část do objemu 2000 dm³), homogenizační kotle Kalibrace – teplota Porovnání s etalonem -80 °C až -50 °C CMC 0,2 °C -50 °C až -50 °C CMC 0,1 °C 0 °C CMC 0,07 °C 0 °C až 300 °C CMC 0,1 °C 300 °C až 500 °C CMC 1,5 °C 500 °C až 800 °C CMC 1,8 °C 800 °C až 1000 °C CMC 2,0 °C 1000 °C až 1200 °C CMC 2,1 °C KEXT 3/036/03 Sterylizatory na gorace powietrze i parowe, suszarki, piece, termostaty, urzadzenia mrozace i chlodzace, laznie cieczowe, wirowki chlodzone, komory klimatyczne (tylko czesc temperaturowa do objetosci 2000 dm³), kotly homogenizacyjne Wzorcowanie – temperatura Porownanie z wzorcem od -80 °C do -50 °C CMC 0,2 °C od -50 °C do -50 °C CMC 0,1 °C 0 °C CMC 0,07 °C od 0 °C do 300 °C CMC 0,1 °C od 300 °C do 500 °C CMC 1,5 °C od 500 °C do 800 °C CMC 1,8 °C od 800 °C do 1000 °C CMC 2,0 °C od 1000 °C do 1200 °C CMC 2,1 °C Sterilizatory horkovzdusne a parni, susarny, pece, termostaty, mrazici a chladici zarizeni, kapalinove lazne, chlazene odstredivky klimaticke komory (jen teplotni cast do objemu 2000 dm³), homogenizacni kotle Kalibrace – teplota Porovnani s etalonem -80 °C az -50 °C CMC 0,2 °C -50 °C az -50 °C CMC 0,1 °C 0 °C CMC 0,07 °C 0 °C az 300 °C CMC 0,1 °C 300 °C az 500 °C CMC 1,5 °C 500 °C az 800 °C CMC 1,8 °C 800 °C az 1000 °C CMC 2,0 °C 1000 °C az 1200 °C CMC 2,1 °C KEXT 3/036/03","search_en":"Hot-air and steam sterilizers, drying ovens, furnaces, thermostats, freezing and cooling equipment, liquid baths, refrigerated centrifuges, climatic chambers (temperature part only, up to a volume of 2000 dm³), homogenization boilers Calibration – temperature Comparison with a standard -80 °C to -50 °C CMC 0,2 °C -50 °C to -50 °C CMC 0,1 °C 0 °C CMC 0,07 °C 0 °C to 300 °C CMC 0,1 °C 300 °C to 500 °C CMC 1,5 °C 500 °C to 800 °C CMC 1,8 °C 800 °C to 1000 °C CMC 2,0 °C 1000 °C to 1200 °C CMC 2,1 °C KEXT 3/036/03","search_zh":"热空气和蒸汽灭菌器、干燥箱、炉、恒温箱、冷冻和冷却设备、液体槽、冷冻离心机、气候箱（仅温度部分，容积至 2000 dm³）、均质锅 校准 – 温度 与标准器比较 -80 °C 至 -50 °C CMC 0,2 °C -50 °C 至 -50 °C CMC 0,1 °C 0 °C CMC 0,07 °C 0 °C 至 300 °C CMC 0,1 °C 300 °C 至 500 °C CMC 1,5 °C 500 °C 至 800 °C CMC 1,8 °C 800 °C 至 1000 °C CMC 2,0 °C 1000 °C 至 1200 °C CMC 2,1 °C KEXT 3/036/03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1c61244ef66dd2441780f01","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"1","test_object":"Higrometry elektroniczne i włosowe","test_object_en":"Electronic and hair hygrometers","test_object_zh":"电子湿度计和毛发湿度计","test_object_cs":"Elektronické a vlasové vlhkoměry","methodology":"Wzorcowanie – wilgotność","methodology_en":"Calibration – humidity","methodology_zh":"校准 – 湿度","methodology_cs":"Kalibrace – vlhkost","parameters":[{"name":"(18 do 25) °C","range":"od 20 % RH do 50 % RH","cmc":"1,5 % RH"},{"name":"(18 do 25) °C","range":"od 50 % RH do 70 % RH","cmc":"1,6 % RH"},{"name":"(18 do 25) °C","range":"od 70 % RH do 90 % RH","cmc":"1,7 % RH"}],"parameters_en":[{"name":"(18 to 25) °C","range":"20 % RH to 50 % RH","cmc":"1,5 % RH"},{"name":"(18 to 25) °C","range":"50 % RH to 70 % RH","cmc":"1,6 % RH"},{"name":"(18 to 25) °C","range":"70 % RH to 90 % RH","cmc":"1,7 % RH"}],"parameters_zh":[{"name":"(18 至 25) °C","range":"20 % RH 至 50 % RH","cmc":"1,5 % RH"},{"name":"(18 至 25) °C","range":"50 % RH 至 70 % RH","cmc":"1,6 % RH"},{"name":"(18 至 25) °C","range":"70 % RH 至 90 % RH","cmc":"1,7 % RH"}],"parameters_cs":[{"name":"(18 až 25) °C","range":"20 % RH až 50 % RH","cmc":"1,5 % RH"},{"name":"(18 až 25) °C","range":"50 % RH až 70 % RH","cmc":"1,6 % RH"},{"name":"(18 až 25) °C","range":"70 % RH až 90 % RH","cmc":"1,7 % RH"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność\nZakres:\n(18 do 25) °C od 20 % RH do 50 % RH CMC 1,5 % RH\n(18 do 25) °C od 50 % RH do 70 % RH CMC 1,6 % RH\n(18 do 25) °C od 70 % RH do 90 % RH CMC 1,7 % RH\nPorównanie z wzorcem","reference":"MKEV 3/039/07","norm_bases":["MKEV 3/039/07"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Humidity","regulatory_area_zh":"被测量领域的CMC：湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry elektroniczne i włosowe Wzorcowanie – wilgotność Porównanie z wzorcem (18 do 25) °C od 20 % RH do 50 % RH CMC 1,5 % RH (18 do 25) °C od 50 % RH do 70 % RH CMC 1,6 % RH (18 do 25) °C od 70 % RH do 90 % RH CMC 1,7 % RH Elektronické a vlasové vlhkoměry Kalibrace – vlhkost Porovnání s etalonem (18 až 25) °C 20 % RH až 50 % RH CMC 1,5 % RH (18 až 25) °C 50 % RH až 70 % RH CMC 1,6 % RH (18 až 25) °C 70 % RH až 90 % RH CMC 1,7 % RH MKEV 3/039/07 Higrometry elektroniczne i wlosowe Wzorcowanie – wilgotnosc Porownanie z wzorcem (18 do 25) °C od 20 % RH do 50 % RH CMC 1,5 % RH (18 do 25) °C od 50 % RH do 70 % RH CMC 1,6 % RH (18 do 25) °C od 70 % RH do 90 % RH CMC 1,7 % RH Elektronicke a vlasove vlhkomery Kalibrace – vlhkost Porovnani s etalonem (18 az 25) °C 20 % RH az 50 % RH CMC 1,5 % RH (18 az 25) °C 50 % RH az 70 % RH CMC 1,6 % RH (18 az 25) °C 70 % RH az 90 % RH CMC 1,7 % RH MKEV 3/039/07","search_en":"Electronic and hair hygrometers Calibration – humidity Comparison with a standard (18 to 25) °C 20 % RH to 50 % RH CMC 1,5 % RH (18 to 25) °C 50 % RH to 70 % RH CMC 1,6 % RH (18 to 25) °C 70 % RH to 90 % RH CMC 1,7 % RH MKEV 3/039/07","search_zh":"电子湿度计和毛发湿度计 校准 – 湿度 与标准器比较 (18 至 25) °C 20 % RH 至 50 % RH CMC 1,5 % RH (18 至 25) °C 50 % RH 至 70 % RH CMC 1,6 % RH (18 至 25) °C 70 % RH 至 90 % RH CMC 1,7 % RH MKEV 3/039/07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c09067d27299eabaaf42fd51","lab_id":"6ade8b2eff06824761708105","country":"CZ","accr_number":"2281","accr_body":"ČIA","row_label":"2","test_object":"Higrometry elektroniczne, higrometry elektroniczne wraz z pętlą (torem pomiarowym)","test_object_en":"Electronic hygrometers, electronic hygrometers incl. the loop (chain)","test_object_zh":"电子湿度计、含回路（测量链）的电子湿度计","test_object_cs":"Elektronické vlhkoměry, elektronické vlhkoměry vč. smyčky (řetězce)","methodology":"Wzorcowanie – wilgotność","methodology_en":"Calibration – humidity","methodology_zh":"校准 – 湿度","methodology_cs":"Kalibrace – vlhkost","parameters":[{"name":"(18 do 25) °C","range":"od 20 % RH do 30 % RH","cmc":"1,6 % RH"},{"name":"(18 do 25) °C","range":"od 30 % RH do 70 % RH","cmc":"1,7 % RH"},{"name":"(18 do 25) °C","range":"od 70 % RH do 90 % RH","cmc":"1,8 % RH"}],"parameters_en":[{"name":"(18 to 25) °C","range":"20 % RH to 30 % RH","cmc":"1,6 % RH"},{"name":"(18 to 25) °C","range":"30 % RH to 70 % RH","cmc":"1,7 % RH"},{"name":"(18 to 25) °C","range":"70 % RH to 90 % RH","cmc":"1,8 % RH"}],"parameters_zh":[{"name":"(18 至 25) °C","range":"20 % RH 至 30 % RH","cmc":"1,6 % RH"},{"name":"(18 至 25) °C","range":"30 % RH 至 70 % RH","cmc":"1,7 % RH"},{"name":"(18 至 25) °C","range":"70 % RH 至 90 % RH","cmc":"1,8 % RH"}],"parameters_cs":[{"name":"(18 až 25) °C","range":"20 % RH až 30 % RH","cmc":"1,6 % RH"},{"name":"(18 až 25) °C","range":"30 % RH až 70 % RH","cmc":"1,7 % RH"},{"name":"(18 až 25) °C","range":"70 % RH až 90 % RH","cmc":"1,8 % RH"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność\nZakres:\n(18 do 25) °C od 20 % RH do 30 % RH CMC 1,6 % RH\n(18 do 25) °C od 30 % RH do 70 % RH CMC 1,7 % RH\n(18 do 25) °C od 70 % RH do 90 % RH CMC 1,8 % RH\nPorównanie z wzorcem","reference":"KEXV 3/041/12","norm_bases":["KEXV 3/041/12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność","regulatory_area_en":"CMC for the field of measured quantity: Humidity","regulatory_area_zh":"被测量领域的CMC：湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry elektroniczne, higrometry elektroniczne wraz z pętlą (torem pomiarowym) Wzorcowanie – wilgotność Porównanie z wzorcem (18 do 25) °C od 20 % RH do 30 % RH CMC 1,6 % RH (18 do 25) °C od 30 % RH do 70 % RH CMC 1,7 % RH (18 do 25) °C od 70 % RH do 90 % RH CMC 1,8 % RH Elektronické vlhkoměry, elektronické vlhkoměry vč. smyčky (řetězce) Kalibrace – vlhkost Porovnání s etalonem (18 až 25) °C 20 % RH až 30 % RH CMC 1,6 % RH (18 až 25) °C 30 % RH až 70 % RH CMC 1,7 % RH (18 až 25) °C 70 % RH až 90 % RH CMC 1,8 % RH KEXV 3/041/12 Higrometry elektroniczne, higrometry elektroniczne wraz z petla (torem pomiarowym) Wzorcowanie – wilgotnosc Porownanie z wzorcem (18 do 25) °C od 20 % RH do 30 % RH CMC 1,6 % RH (18 do 25) °C od 30 % RH do 70 % RH CMC 1,7 % RH (18 do 25) °C od 70 % RH do 90 % RH CMC 1,8 % RH Elektronicke vlhkomery, elektronicke vlhkomery vc. smycky (retezce) Kalibrace – vlhkost Porovnani s etalonem (18 az 25) °C 20 % RH az 30 % RH CMC 1,6 % RH (18 az 25) °C 30 % RH az 70 % RH CMC 1,7 % RH (18 az 25) °C 70 % RH az 90 % RH CMC 1,8 % RH KEXV 3/041/12","search_en":"Electronic hygrometers, electronic hygrometers incl. the loop (chain) Calibration – humidity Comparison with a standard (18 to 25) °C 20 % RH to 30 % RH CMC 1,6 % RH (18 to 25) °C 30 % RH to 70 % RH CMC 1,7 % RH (18 to 25) °C 70 % RH to 90 % RH CMC 1,8 % RH KEXV 3/041/12","search_zh":"电子湿度计、含回路（测量链）的电子湿度计 校准 – 湿度 与标准器比较 (18 至 25) °C 20 % RH 至 30 % RH CMC 1,6 % RH (18 至 25) °C 30 % RH 至 70 % RH CMC 1,7 % RH (18 至 25) °C 70 % RH 至 90 % RH CMC 1,8 % RH KEXV 3/041/12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}