{"lab":{"_id":"6ade8b5fff0682476170815a","accr_number":"2273","country":"CZ","accr_body":"ČIA","address":"U Dráhy 411/11, 664 49 Ostopovice","categories":["metrology"],"city":"Ostopovice","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[16.5468053,49.1629898]},"map_coord":[49.1629898,16.5468053],"map_geo":"cai-mapa","methods_count":87,"name":"HES, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: ciśnienie, temperatura, wielkości elektryczne, wielkości czasu i częstotliwości, wilgotność, w zakresie określonym w załączniku do świadectwa.","search_text":"hes, s.r.o. u dráhy 411/11, 664 49 ostopovice 2273","source_page_url":"https://www.cai.cz/?subjekt=2273-hes-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"14-02-2027","website":"www.hes-sro.cz","certificate_date":"16.02.2026","certificate_no":"76/2026","certificate_replaces":"503/2024 z 27.09.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: ciśnienie, temperatura, wielkości elektryczne, wielkości czasu i częstotliwości, wilgotność, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of pressure, temperature, electrical quantities, time and frequency, humidity to the extent as specified in the appendix to this Certificate.","zh":"压力、温度、电学量、时间和频率量、湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech tlak, teplota, elektrické veličiny, veličiny času a frekvence, vlhkost, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"CJC","pl":"kompensacja zimnego końca","en":"Cold Junction Compensation","zh":"冷端补偿","cs":"kompenzace studeného konce"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"c058a1d15c5fb92d5e68d4b2c50dd5941dcb1d296b15bd0298f18e036ba6b6f1","source_pdf_url":"https://www.cai.cz/OA/pdf/76_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/76_2026_EN.pdf"},"methods":[{"_id":"82497aabf3f6b5883391e494","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste, manometry wskazówkowe, ciśnieniomierze cyfrowe, manometry cyfrowe, przetworniki ciśnienia, tory pomiarowe ciśnienia, kalibratory ciśnienia, barometry, lotnicze wysokościomierze ciśnieniowe, prędkościomierze ciśnieniowe i lotnicze kalibratory ciśnienia","test_object_en":"Deformation manometers, pointer manometers, digital manometers, digital pressure converters, pressure measuring chains, pressure calibrators, barometers, aircraft pressure altimeters, pressure airspeed indicators and aircraft pressure calibrators","test_object_zh":"弹性式压力表、指针式压力表、数字压力计、数字式压力表、压力变送器、压力测量链、压力校准器、气压计、航空气压高度表、气压空速表和航空压力校准器","test_object_cs":"Deformační tlakoměry, ručkové manometry, číslicové tlakoměry digitální manometry, převodníky tlaku, měřicí řetězce tlaku, kalibrátory tlaku, barometry, letecké tlakové výškoměry, tlakové rychloměry a letecké tlakové kalibrátory","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"gaz; ciśnienie absolutne","range":"od 1 kPa do 30 kPa","cmc":"7 Pa"},{"name":"gaz; ciśnienie absolutne","range":"od 30 kPa do 107 kPa","cmc":"8 Pa"},{"name":"gaz; ciśnienie absolutne","range":"od 107 kPa do 130 kPa","cmc":"12 Pa"},{"name":"gaz; ciśnienie absolutne","range":"od 130 kPa do 173 kPa","cmc":"16 Pa"},{"name":"gaz; ciśnienie absolutne","range":"od 173 kPa do 225 kPa","cmc":"20 Pa"},{"name":"gaz; ciśnienie absolutne","range":"od 225 kPa do 270 kPa","cmc":"24 Pa"},{"name":"gaz; ciśnienie absolutne","range":"od 270 kPa do 350 kPa","cmc":"32 Pa"},{"name":"gaz; podciśnienie","range":"od 0 kPa do 2,5 kPa","cmc":"2,4 Pa"},{"name":"gaz; podciśnienie","range":"od 2,5 kPa do 35 kPa","cmc":"32 Pa"},{"name":"gaz; podciśnienie","range":"od 35 kPa do 100 kPa","cmc":"45 Pa"},{"name":"gaz; nadciśnienie","range":"od 0,2 MPa do 0,7 MPa","cmc":"0,17 kPa"},{"name":"gaz; nadciśnienie","range":"od 0,7 MPa do 3,5 MPa","cmc":"0,43 kPa"},{"name":"gaz; nadciśnienie","range":"od 3,5 MPa do 20 MPa","cmc":"4,7 kPa"},{"name":"gaz; nadciśnienie","range":"od 20 MPa do 30 MPa","cmc":"21 kPa"},{"name":"ciecz (woda, alkohol, olej); nadciśnienie","range":"od 0 kPa do 2,5 kPa","cmc":"2,4 Pa"},{"name":"ciecz (woda, alkohol, olej); nadciśnienie","range":"od 2,5 kPa do 35 kPa","cmc":"32 Pa"},{"name":"ciecz (woda, alkohol, olej); nadciśnienie","range":"od 35 kPa do 100 kPa","cmc":"2,1 kPa"},{"name":"ciecz (woda, alkohol, olej); nadciśnienie","range":"od 12 MPa do 35 MPa","cmc":"21 kPa"},{"name":"ciecz (woda, alkohol, olej); nadciśnienie","range":"od 35 MPa do 70 MPa","cmc":"40 kPa"}],"parameters_en":[{"name":"gas; absolute pressure","range":"1 kPa to 30 kPa","cmc":"7 Pa"},{"name":"gas; absolute pressure","range":"30 kPa to 107 kPa","cmc":"8 Pa"},{"name":"gas; absolute pressure","range":"107 kPa to 130 kPa","cmc":"12 Pa"},{"name":"gas; absolute pressure","range":"130 kPa to 173 kPa","cmc":"16 Pa"},{"name":"gas; absolute pressure","range":"173 kPa to 225 kPa","cmc":"20 Pa"},{"name":"gas; absolute pressure","range":"225 kPa to 270 kPa","cmc":"24 Pa"},{"name":"gas; absolute pressure","range":"270 kPa to 350 kPa","cmc":"32 Pa"},{"name":"gas; negative gauge pressure","range":"0 kPa to 2,5 kPa","cmc":"2,4 Pa"},{"name":"gas; negative gauge pressure","range":"2,5 kPa to 35 kPa","cmc":"32 Pa"},{"name":"gas; negative gauge pressure","range":"35 kPa to 100 kPa","cmc":"45 Pa"},{"name":"gas; positive gauge pressure","range":"0,2 MPa to 0,7 MPa","cmc":"0,17 kPa"},{"name":"gas; positive gauge pressure","range":"0,7 MPa to 3,5 MPa","cmc":"0,43 kPa"},{"name":"gas; positive gauge pressure","range":"3,5 MPa to 20 MPa","cmc":"4,7 kPa"},{"name":"gas; positive gauge pressure","range":"20 MPa to 30 MPa","cmc":"21 kPa"},{"name":"liquid (water, alcohol, oil); positive gauge pressure","range":"0 kPa to 2,5 kPa","cmc":"2,4 Pa"},{"name":"liquid (water, alcohol, oil); positive gauge pressure","range":"2,5 kPa to 35 kPa","cmc":"32 Pa"},{"name":"liquid (water, alcohol, oil); positive gauge pressure","range":"35 kPa to 100 kPa","cmc":"2,1 kPa"},{"name":"liquid (water, alcohol, oil); positive gauge pressure","range":"12 MPa to 35 MPa","cmc":"21 kPa"},{"name":"liquid (water, alcohol, oil); positive gauge pressure","range":"35 MPa to 70 MPa","cmc":"40 kPa"}],"parameters_zh":[{"name":"气体；绝对压力","range":"1 kPa 至 30 kPa","cmc":"7 Pa"},{"name":"气体；绝对压力","range":"30 kPa 至 107 kPa","cmc":"8 Pa"},{"name":"气体；绝对压力","range":"107 kPa 至 130 kPa","cmc":"12 Pa"},{"name":"气体；绝对压力","range":"130 kPa 至 173 kPa","cmc":"16 Pa"},{"name":"气体；绝对压力","range":"173 kPa 至 225 kPa","cmc":"20 Pa"},{"name":"气体；绝对压力","range":"225 kPa 至 270 kPa","cmc":"24 Pa"},{"name":"气体；绝对压力","range":"270 kPa 至 350 kPa","cmc":"32 Pa"},{"name":"气体；负表压","range":"0 kPa 至 2,5 kPa","cmc":"2,4 Pa"},{"name":"气体；负表压","range":"2,5 kPa 至 35 kPa","cmc":"32 Pa"},{"name":"气体；负表压","range":"35 kPa 至 100 kPa","cmc":"45 Pa"},{"name":"气体；正表压","range":"0,2 MPa 至 0,7 MPa","cmc":"0,17 kPa"},{"name":"气体；正表压","range":"0,7 MPa 至 3,5 MPa","cmc":"0,43 kPa"},{"name":"气体；正表压","range":"3,5 MPa 至 20 MPa","cmc":"4,7 kPa"},{"name":"气体；正表压","range":"20 MPa 至 30 MPa","cmc":"21 kPa"},{"name":"液体（水、酒精、油）；正表压","range":"0 kPa 至 2,5 kPa","cmc":"2,4 Pa"},{"name":"液体（水、酒精、油）；正表压","range":"2,5 kPa 至 35 kPa","cmc":"32 Pa"},{"name":"液体（水、酒精、油）；正表压","range":"35 kPa 至 100 kPa","cmc":"2,1 kPa"},{"name":"液体（水、酒精、油）；正表压","range":"12 MPa 至 35 MPa","cmc":"21 kPa"},{"name":"液体（水、酒精、油）；正表压","range":"35 MPa 至 70 MPa","cmc":"40 kPa"}],"parameters_cs":[{"name":"plyn; absolutní tlak","range":"1 kPa až 30 kPa","cmc":"7 Pa"},{"name":"plyn; absolutní tlak","range":"30 kPa až 107 kPa","cmc":"8 Pa"},{"name":"plyn; absolutní tlak","range":"107 kPa až 130 kPa","cmc":"12 Pa"},{"name":"plyn; absolutní tlak","range":"130 kPa až 173 kPa","cmc":"16 Pa"},{"name":"plyn; absolutní tlak","range":"173 kPa až 225 kPa","cmc":"20 Pa"},{"name":"plyn; absolutní tlak","range":"225 kPa až 270 kPa","cmc":"24 Pa"},{"name":"plyn; absolutní tlak","range":"270 kPa až 350 kPa","cmc":"32 Pa"},{"name":"plyn; podtlak","range":"0 kPa až 2,5 kPa","cmc":"2,4 Pa"},{"name":"plyn; podtlak","range":"2,5 kPa až 35 kPa","cmc":"32 Pa"},{"name":"plyn; podtlak","range":"35 kPa až 100 kPa","cmc":"45 Pa"},{"name":"plyn; přetlak","range":"0,2 MPa až 0,7 MPa","cmc":"0,17 kPa"},{"name":"plyn; přetlak","range":"0,7 MPa až 3,5 MPa","cmc":"0,43 kPa"},{"name":"plyn; přetlak","range":"3,5 MPa až 20 MPa","cmc":"4,7 kPa"},{"name":"plyn; přetlak","range":"20 MPa až 30 MPa","cmc":"21 kPa"},{"name":"kapalina (voda, líh, olej); přetlak","range":"0 kPa až 2,5 kPa","cmc":"2,4 Pa"},{"name":"kapalina (voda, líh, olej); přetlak","range":"2,5 kPa až 35 kPa","cmc":"32 Pa"},{"name":"kapalina (voda, líh, olej); přetlak","range":"35 kPa až 100 kPa","cmc":"2,1 kPa"},{"name":"kapalina (voda, líh, olej); přetlak","range":"12 MPa až 35 MPa","cmc":"21 kPa"},{"name":"kapalina (voda, líh, olej); přetlak","range":"35 MPa až 70 MPa","cmc":"40 kPa"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a standard digital manometer","technique_zh":"与标准数字压力计比较","technique_cs":"Porovnání s etalonovým digitálním tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a standard digital manometer"],"techniques_zh":["与标准数字压力计比较"],"techniques_cs":["Porovnání s etalonovým digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\ngaz; ciśnienie absolutne od 1 kPa do 30 kPa CMC 7 Pa\ngaz; ciśnienie absolutne od 30 kPa do 107 kPa CMC 8 Pa\ngaz; ciśnienie absolutne od 107 kPa do 130 kPa CMC 12 Pa\ngaz; ciśnienie absolutne od 130 kPa do 173 kPa CMC 16 Pa\ngaz; ciśnienie absolutne od 173 kPa do 225 kPa CMC 20 Pa\ngaz; ciśnienie absolutne od 225 kPa do 270 kPa CMC 24 Pa\ngaz; ciśnienie absolutne od 270 kPa do 350 kPa CMC 32 Pa\ngaz; podciśnienie od 0 kPa do 2,5 kPa CMC 2,4 Pa\ngaz; podciśnienie od 2,5 kPa do 35 kPa CMC 32 Pa\ngaz; podciśnienie od 35 kPa do 100 kPa CMC 45 Pa\ngaz; nadciśnienie od 0,2 MPa do 0,7 MPa CMC 0,17 kPa\ngaz; nadciśnienie od 0,7 MPa do 3,5 MPa CMC 0,43 kPa\ngaz; nadciśnienie od 3,5 MPa do 20 MPa CMC 4,7 kPa\ngaz; nadciśnienie od 20 MPa do 30 MPa CMC 21 kPa\nciecz (woda, alkohol, olej); nadciśnienie od 0 kPa do 2,5 kPa CMC 2,4 Pa\nciecz (woda, alkohol, olej); nadciśnienie od 2,5 kPa do 35 kPa CMC 32 Pa\nciecz (woda, alkohol, olej); nadciśnienie od 35 kPa do 100 kPa CMC 2,1 kPa\nciecz (woda, alkohol, olej); nadciśnienie od 12 MPa do 35 MPa CMC 21 kPa\nciecz (woda, alkohol, olej); nadciśnienie od 35 MPa do 70 MPa CMC 40 kPa\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"TP40, TP41, TP42, TP43","norm_bases":["TP40","TP41","TP42","TP43"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste, manometry wskazówkowe, ciśnieniomierze cyfrowe, manometry cyfrowe, przetworniki ciśnienia, tory pomiarowe ciśnienia, kalibratory ciśnienia, barometry, lotnicze wysokościomierze ciśnieniowe, prędkościomierze ciśnieniowe i lotnicze kalibratory ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym gaz; ciśnienie absolutne od 1 kPa do 30 kPa CMC 7 Pa gaz; ciśnienie absolutne od 30 kPa do 107 kPa CMC 8 Pa gaz; ciśnienie absolutne od 107 kPa do 130 kPa CMC 12 Pa gaz; ciśnienie absolutne od 130 kPa do 173 kPa CMC 16 Pa gaz; ciśnienie absolutne od 173 kPa do 225 kPa CMC 20 Pa gaz; ciśnienie absolutne od 225 kPa do 270 kPa CMC 24 Pa gaz; ciśnienie absolutne od 270 kPa do 350 kPa CMC 32 Pa gaz; podciśnienie od 0 kPa do 2,5 kPa CMC 2,4 Pa gaz; podciśnienie od 2,5 kPa do 35 kPa CMC 32 Pa gaz; podciśnienie od 35 kPa do 100 kPa CMC 45 Pa gaz; nadciśnienie od 0,2 MPa do 0,7 MPa CMC 0,17 kPa gaz; nadciśnienie od 0,7 MPa do 3,5 MPa CMC 0,43 kPa gaz; nadciśnienie od 3,5 MPa do 20 MPa CMC 4,7 kPa gaz; nadciśnienie od 20 MPa do 30 MPa CMC 21 kPa ciecz (woda, alkohol, olej); nadciśnienie od 0 kPa do 2,5 kPa CMC 2,4 Pa ciecz (woda, alkohol, olej); nadciśnienie od 2,5 kPa do 35 kPa CMC 32 Pa ciecz (woda, alkohol, olej); nadciśnienie od 35 kPa do 100 kPa CMC 2,1 kPa ciecz (woda, alkohol, olej); nadciśnienie od 12 MPa do 35 MPa CMC 21 kPa ciecz (woda, alkohol, olej); nadciśnienie od 35 MPa do 70 MPa CMC 40 kPa Deformační tlakoměry, ručkové manometry, číslicové tlakoměry digitální manometry, převodníky tlaku, měřicí řetězce tlaku, kalibrátory tlaku, barometry, letecké tlakové výškoměry, tlakové rychloměry a letecké tlakové kalibrátory Kalibrace – tlak Porovnání s etalonovým digitálním tlakoměrem plyn; absolutní tlak 1 kPa až 30 kPa CMC 7 Pa plyn; absolutní tlak 30 kPa až 107 kPa CMC 8 Pa plyn; absolutní tlak 107 kPa až 130 kPa CMC 12 Pa plyn; absolutní tlak 130 kPa až 173 kPa CMC 16 Pa plyn; absolutní tlak 173 kPa až 225 kPa CMC 20 Pa plyn; absolutní tlak 225 kPa až 270 kPa CMC 24 Pa plyn; absolutní tlak 270 kPa až 350 kPa CMC 32 Pa plyn; podtlak 0 kPa až 2,5 kPa CMC 2,4 Pa plyn; podtlak 2,5 kPa až 35 kPa CMC 32 Pa plyn; podtlak 35 kPa až 100 kPa CMC 45 Pa plyn; přetlak 0,2 MPa až 0,7 MPa CMC 0,17 kPa plyn; přetlak 0,7 MPa až 3,5 MPa CMC 0,43 kPa plyn; přetlak 3,5 MPa až 20 MPa CMC 4,7 kPa plyn; přetlak 20 MPa až 30 MPa CMC 21 kPa kapalina (voda, líh, olej); přetlak 0 kPa až 2,5 kPa CMC 2,4 Pa kapalina (voda, líh, olej); přetlak 2,5 kPa až 35 kPa CMC 32 Pa kapalina (voda, líh, olej); přetlak 35 kPa až 100 kPa CMC 2,1 kPa kapalina (voda, líh, olej); přetlak 12 MPa až 35 MPa CMC 21 kPa kapalina (voda, líh, olej); přetlak 35 MPa až 70 MPa CMC 40 kPa TP40, TP41, TP42, TP43 Cisnieniomierze sprezyste, manometry wskazowkowe, cisnieniomierze cyfrowe, manometry cyfrowe, przetworniki cisnienia, tory pomiarowe cisnienia, kalibratory cisnienia, barometry, lotnicze wysokosciomierze cisnieniowe, predkosciomierze cisnieniowe i lotnicze kalibratory cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym gaz; cisnienie absolutne od 1 kPa do 30 kPa CMC 7 Pa gaz; cisnienie absolutne od 30 kPa do 107 kPa CMC 8 Pa gaz; cisnienie absolutne od 107 kPa do 130 kPa CMC 12 Pa gaz; cisnienie absolutne od 130 kPa do 173 kPa CMC 16 Pa gaz; cisnienie absolutne od 173 kPa do 225 kPa CMC 20 Pa gaz; cisnienie absolutne od 225 kPa do 270 kPa CMC 24 Pa gaz; cisnienie absolutne od 270 kPa do 350 kPa CMC 32 Pa gaz; podcisnienie od 0 kPa do 2,5 kPa CMC 2,4 Pa gaz; podcisnienie od 2,5 kPa do 35 kPa CMC 32 Pa gaz; podcisnienie od 35 kPa do 100 kPa CMC 45 Pa gaz; nadcisnienie od 0,2 MPa do 0,7 MPa CMC 0,17 kPa gaz; nadcisnienie od 0,7 MPa do 3,5 MPa CMC 0,43 kPa gaz; nadcisnienie od 3,5 MPa do 20 MPa CMC 4,7 kPa gaz; nadcisnienie od 20 MPa do 30 MPa CMC 21 kPa ciecz (woda, alkohol, olej); nadcisnienie od 0 kPa do 2,5 kPa CMC 2,4 Pa ciecz (woda, alkohol, olej); nadcisnienie od 2,5 kPa do 35 kPa CMC 32 Pa ciecz (woda, alkohol, olej); nadcisnienie od 35 kPa do 100 kPa CMC 2,1 kPa ciecz (woda, alkohol, olej); nadcisnienie od 12 MPa do 35 MPa CMC 21 kPa ciecz (woda, alkohol, olej); nadcisnienie od 35 MPa do 70 MPa CMC 40 kPa Deformacni tlakomery, ruckove manometry, cislicove tlakomery digitalni manometry, prevodniky tlaku, merici retezce tlaku, kalibratory tlaku, barometry, letecke tlakove vyskomery, tlakove rychlomery a letecke tlakove kalibratory Kalibrace – tlak Porovnani s etalonovym digitalnim tlakomerem plyn; absolutni tlak 1 kPa az 30 kPa CMC 7 Pa plyn; absolutni tlak 30 kPa az 107 kPa CMC 8 Pa plyn; absolutni tlak 107 kPa az 130 kPa CMC 12 Pa plyn; absolutni tlak 130 kPa az 173 kPa CMC 16 Pa plyn; absolutni tlak 173 kPa az 225 kPa CMC 20 Pa plyn; absolutni tlak 225 kPa az 270 kPa CMC 24 Pa plyn; absolutni tlak 270 kPa az 350 kPa CMC 32 Pa plyn; podtlak 0 kPa az 2,5 kPa CMC 2,4 Pa plyn; podtlak 2,5 kPa az 35 kPa CMC 32 Pa plyn; podtlak 35 kPa az 100 kPa CMC 45 Pa plyn; pretlak 0,2 MPa az 0,7 MPa CMC 0,17 kPa plyn; pretlak 0,7 MPa az 3,5 MPa CMC 0,43 kPa plyn; pretlak 3,5 MPa az 20 MPa CMC 4,7 kPa plyn; pretlak 20 MPa az 30 MPa CMC 21 kPa kapalina (voda, lih, olej); pretlak 0 kPa az 2,5 kPa CMC 2,4 Pa kapalina (voda, lih, olej); pretlak 2,5 kPa az 35 kPa CMC 32 Pa kapalina (voda, lih, olej); pretlak 35 kPa az 100 kPa CMC 2,1 kPa kapalina (voda, lih, olej); pretlak 12 MPa az 35 MPa CMC 21 kPa kapalina (voda, lih, olej); pretlak 35 MPa az 70 MPa CMC 40 kPa TP40, TP41, TP42, TP43","search_en":"Deformation manometers, pointer manometers, digital manometers, digital pressure converters, pressure measuring chains, pressure calibrators, barometers, aircraft pressure altimeters, pressure airspeed indicators and aircraft pressure calibrators Calibration – pressure Comparison with a standard digital manometer gas; absolute pressure 1 kPa to 30 kPa CMC 7 Pa gas; absolute pressure 30 kPa to 107 kPa CMC 8 Pa gas; absolute pressure 107 kPa to 130 kPa CMC 12 Pa gas; absolute pressure 130 kPa to 173 kPa CMC 16 Pa gas; absolute pressure 173 kPa to 225 kPa CMC 20 Pa gas; absolute pressure 225 kPa to 270 kPa CMC 24 Pa gas; absolute pressure 270 kPa to 350 kPa CMC 32 Pa gas; negative gauge pressure 0 kPa to 2,5 kPa CMC 2,4 Pa gas; negative gauge pressure 2,5 kPa to 35 kPa CMC 32 Pa gas; negative gauge pressure 35 kPa to 100 kPa CMC 45 Pa gas; positive gauge pressure 0,2 MPa to 0,7 MPa CMC 0,17 kPa gas; positive gauge pressure 0,7 MPa to 3,5 MPa CMC 0,43 kPa gas; positive gauge pressure 3,5 MPa to 20 MPa CMC 4,7 kPa gas; positive gauge pressure 20 MPa to 30 MPa CMC 21 kPa liquid (water, alcohol, oil); positive gauge pressure 0 kPa to 2,5 kPa CMC 2,4 Pa liquid (water, alcohol, oil); positive gauge pressure 2,5 kPa to 35 kPa CMC 32 Pa liquid (water, alcohol, oil); positive gauge pressure 35 kPa to 100 kPa CMC 2,1 kPa liquid (water, alcohol, oil); positive gauge pressure 12 MPa to 35 MPa CMC 21 kPa liquid (water, alcohol, oil); positive gauge pressure 35 MPa to 70 MPa CMC 40 kPa TP40, TP41, TP42, TP43","search_zh":"弹性式压力表、指针式压力表、数字压力计、数字式压力表、压力变送器、压力测量链、压力校准器、气压计、航空气压高度表、气压空速表和航空压力校准器 校准 – 压力 与标准数字压力计比较 气体；绝对压力 1 kPa 至 30 kPa CMC 7 Pa 气体；绝对压力 30 kPa 至 107 kPa CMC 8 Pa 气体；绝对压力 107 kPa 至 130 kPa CMC 12 Pa 气体；绝对压力 130 kPa 至 173 kPa CMC 16 Pa 气体；绝对压力 173 kPa 至 225 kPa CMC 20 Pa 气体；绝对压力 225 kPa 至 270 kPa CMC 24 Pa 气体；绝对压力 270 kPa 至 350 kPa CMC 32 Pa 气体；负表压 0 kPa 至 2,5 kPa CMC 2,4 Pa 气体；负表压 2,5 kPa 至 35 kPa CMC 32 Pa 气体；负表压 35 kPa 至 100 kPa CMC 45 Pa 气体；正表压 0,2 MPa 至 0,7 MPa CMC 0,17 kPa 气体；正表压 0,7 MPa 至 3,5 MPa CMC 0,43 kPa 气体；正表压 3,5 MPa 至 20 MPa CMC 4,7 kPa 气体；正表压 20 MPa 至 30 MPa CMC 21 kPa 液体（水、酒精、油）；正表压 0 kPa 至 2,5 kPa CMC 2,4 Pa 液体（水、酒精、油）；正表压 2,5 kPa 至 35 kPa CMC 32 Pa 液体（水、酒精、油）；正表压 35 kPa 至 100 kPa CMC 2,1 kPa 液体（水、酒精、油）；正表压 12 MPa 至 35 MPa CMC 21 kPa 液体（水、酒精、油）；正表压 35 MPa 至 70 MPa CMC 40 kPa TP40, TP41, TP42, TP43","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f9c998b612265b2c686f7248","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste, manometry wskazówkowe, ciśnieniomierze cyfrowe, manometry cyfrowe, przetworniki ciśnienia, tory pomiarowe ciśnienia, kalibratory ciśnienia, barometry, lotnicze wysokościomierze ciśnieniowe, prędkościomierze ciśnieniowe i lotnicze kalibratory ciśnienia","test_object_en":"Deformation manometers, pointer manometers, digital manometers, digital pressure converters, pressure measuring chains, pressure calibrators, barometers, aircraft pressure altimeters, pressure airspeed indicators and aircraft pressure calibrators","test_object_zh":"弹性式压力表、指针式压力表、数字压力计、数字式压力表、压力变送器、压力测量链、压力校准器、气压计、航空气压高度表、气压空速表和航空压力校准器","test_object_cs":"Deformační tlakoměry, ručkové manometry, číslicové tlakoměry digitální manometry, převodníky tlaku, měřicí řetězce tlaku, kalibrátory tlaku, barometry, letecké tlakové výškoměry, tlakové rychloměry a letecké tlakové kalibrátory","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"gaz; nadciśnienie","range":"od 0 kPa do 20 kPa","cmc":"2,4 Pa"},{"name":"gaz; nadciśnienie","range":"od 20 kPa do 200 kPa","cmc":"0,011 %"},{"name":"ciecz (woda, alkohol, olej); nadciśnienie","range":"od 0,1 MPa do 1,2 MPa","cmc":"0,22 kPa"},{"name":"ciecz (woda, alkohol, olej); nadciśnienie","range":"od 1,2 MPa do 12 MPa","cmc":"0,018 %"}],"parameters_en":[{"name":"gas; positive gauge pressure","range":"0 kPa to 20 kPa","cmc":"2,4 Pa"},{"name":"gas; positive gauge pressure","range":"20 kPa to 200 kPa","cmc":"0,011 %"},{"name":"liquid (water, alcohol, oil); positive gauge pressure","range":"0,1 MPa to 1,2 MPa","cmc":"0,22 kPa"},{"name":"liquid (water, alcohol, oil); positive gauge pressure","range":"1,2 MPa to 12 MPa","cmc":"0,018 %"}],"parameters_zh":[{"name":"气体；正表压","range":"0 kPa 至 20 kPa","cmc":"2,4 Pa"},{"name":"气体；正表压","range":"20 kPa 至 200 kPa","cmc":"0,011 %"},{"name":"液体（水、酒精、油）；正表压","range":"0,1 MPa 至 1,2 MPa","cmc":"0,22 kPa"},{"name":"液体（水、酒精、油）；正表压","range":"1,2 MPa 至 12 MPa","cmc":"0,018 %"}],"parameters_cs":[{"name":"plyn; přetlak","range":"0 kPa až 20 kPa","cmc":"2,4 Pa"},{"name":"plyn; přetlak","range":"20 kPa až 200 kPa","cmc":"0,011 %"},{"name":"kapalina (voda, líh, olej); přetlak","range":"0,1 MPa až 1,2 MPa","cmc":"0,22 kPa"},{"name":"kapalina (voda, líh, olej); přetlak","range":"1,2 MPa až 12 MPa","cmc":"0,018 %"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem tłokowym","technique_en":"Comparison with a standard piston manometer","technique_zh":"与标准活塞式压力计比较","technique_cs":"Porovnání s etalonovým pístovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem tłokowym"],"techniques_en":["Comparison with a standard piston manometer"],"techniques_zh":["与标准活塞式压力计比较"],"techniques_cs":["Porovnání s etalonovým pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\ngaz; nadciśnienie od 0 kPa do 20 kPa CMC 2,4 Pa\ngaz; nadciśnienie od 20 kPa do 200 kPa CMC 0,011 %\nciecz (woda, alkohol, olej); nadciśnienie od 0,1 MPa do 1,2 MPa CMC 0,22 kPa\nciecz (woda, alkohol, olej); nadciśnienie od 1,2 MPa do 12 MPa CMC 0,018 %\nPorównanie z wzorcowym ciśnieniomierzem tłokowym","reference":"TP40, TP41, TP42, TP43","norm_bases":["TP40","TP41","TP42","TP43"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste, manometry wskazówkowe, ciśnieniomierze cyfrowe, manometry cyfrowe, przetworniki ciśnienia, tory pomiarowe ciśnienia, kalibratory ciśnienia, barometry, lotnicze wysokościomierze ciśnieniowe, prędkościomierze ciśnieniowe i lotnicze kalibratory ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem tłokowym gaz; nadciśnienie od 0 kPa do 20 kPa CMC 2,4 Pa gaz; nadciśnienie od 20 kPa do 200 kPa CMC 0,011 % ciecz (woda, alkohol, olej); nadciśnienie od 0,1 MPa do 1,2 MPa CMC 0,22 kPa ciecz (woda, alkohol, olej); nadciśnienie od 1,2 MPa do 12 MPa CMC 0,018 % Deformační tlakoměry, ručkové manometry, číslicové tlakoměry digitální manometry, převodníky tlaku, měřicí řetězce tlaku, kalibrátory tlaku, barometry, letecké tlakové výškoměry, tlakové rychloměry a letecké tlakové kalibrátory Kalibrace – tlak Porovnání s etalonovým pístovým tlakoměrem plyn; přetlak 0 kPa až 20 kPa CMC 2,4 Pa plyn; přetlak 20 kPa až 200 kPa CMC 0,011 % kapalina (voda, líh, olej); přetlak 0,1 MPa až 1,2 MPa CMC 0,22 kPa kapalina (voda, líh, olej); přetlak 1,2 MPa až 12 MPa CMC 0,018 % TP40, TP41, TP42, TP43 Cisnieniomierze sprezyste, manometry wskazowkowe, cisnieniomierze cyfrowe, manometry cyfrowe, przetworniki cisnienia, tory pomiarowe cisnienia, kalibratory cisnienia, barometry, lotnicze wysokosciomierze cisnieniowe, predkosciomierze cisnieniowe i lotnicze kalibratory cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem tlokowym gaz; nadcisnienie od 0 kPa do 20 kPa CMC 2,4 Pa gaz; nadcisnienie od 20 kPa do 200 kPa CMC 0,011 % ciecz (woda, alkohol, olej); nadcisnienie od 0,1 MPa do 1,2 MPa CMC 0,22 kPa ciecz (woda, alkohol, olej); nadcisnienie od 1,2 MPa do 12 MPa CMC 0,018 % Deformacni tlakomery, ruckove manometry, cislicove tlakomery digitalni manometry, prevodniky tlaku, merici retezce tlaku, kalibratory tlaku, barometry, letecke tlakove vyskomery, tlakove rychlomery a letecke tlakove kalibratory Kalibrace – tlak Porovnani s etalonovym pistovym tlakomerem plyn; pretlak 0 kPa az 20 kPa CMC 2,4 Pa plyn; pretlak 20 kPa az 200 kPa CMC 0,011 % kapalina (voda, lih, olej); pretlak 0,1 MPa az 1,2 MPa CMC 0,22 kPa kapalina (voda, lih, olej); pretlak 1,2 MPa az 12 MPa CMC 0,018 % TP40, TP41, TP42, TP43","search_en":"Deformation manometers, pointer manometers, digital manometers, digital pressure converters, pressure measuring chains, pressure calibrators, barometers, aircraft pressure altimeters, pressure airspeed indicators and aircraft pressure calibrators Calibration – pressure Comparison with a standard piston manometer gas; positive gauge pressure 0 kPa to 20 kPa CMC 2,4 Pa gas; positive gauge pressure 20 kPa to 200 kPa CMC 0,011 % liquid (water, alcohol, oil); positive gauge pressure 0,1 MPa to 1,2 MPa CMC 0,22 kPa liquid (water, alcohol, oil); positive gauge pressure 1,2 MPa to 12 MPa CMC 0,018 % TP40, TP41, TP42, TP43","search_zh":"弹性式压力表、指针式压力表、数字压力计、数字式压力表、压力变送器、压力测量链、压力校准器、气压计、航空气压高度表、气压空速表和航空压力校准器 校准 – 压力 与标准活塞式压力计比较 气体；正表压 0 kPa 至 20 kPa CMC 2,4 Pa 气体；正表压 20 kPa 至 200 kPa CMC 0,011 % 液体（水、酒精、油）；正表压 0,1 MPa 至 1,2 MPa CMC 0,22 kPa 液体（水、酒精、油）；正表压 1,2 MPa 至 12 MPa CMC 0,018 % TP40, TP41, TP42, TP43","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c6fa652da1bd82ac5ec438a","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy","test_object_en":"Direct indicating thermometers and temperature measuring chains, electronic and analogue thermometers, resistance thermometers, thermoelectric thermometers and thermocouples","test_object_zh":"直读式温度计和温度测量链、电子和模拟温度计、电阻温度计、热电温度计和热电偶","test_object_cs":"Přímo ukazující teploměry a měřicí řetězce teploty, elektronické a analogové teploměry, odporové teploměry, termoelektrické teploměry a termočlánky","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,32 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,32 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,32 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,32 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem","technique_en":"Comparison with a standard resistance sensor in a nitrogen vessel","technique_zh":"在液氮容器中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem"],"techniques_en":["Comparison with a standard resistance sensor in a nitrogen vessel"],"techniques_zh":["在液氮容器中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n-196 °C CMC 0,32 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem","reference":"TP44.1","norm_bases":["TP44.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem -196 °C CMC 0,32 °C Přímo ukazující teploměry a měřicí řetězce teploty, elektronické a analogové teploměry, odporové teploměry, termoelektrické teploměry a termočlánky Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem -196 °C CMC 0,32 °C TP44.1 Termometry bezposrednio wskazujace i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem -196 °C CMC 0,32 °C Primo ukazujici teplomery a merici retezce teploty, elektronicke a analogove teplomery, odporove teplomery, termoelektricke teplomery a termoclanky Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v nadobe s dusikem -196 °C CMC 0,32 °C TP44.1","search_en":"Direct indicating thermometers and temperature measuring chains, electronic and analogue thermometers, resistance thermometers, thermoelectric thermometers and thermocouples Calibration – temperature Comparison with a standard resistance sensor in a nitrogen vessel -196 °C CMC 0,32 °C TP44.1","search_zh":"直读式温度计和温度测量链、电子和模拟温度计、电阻温度计、热电温度计和热电偶 校准 – 温度 在液氮容器中与标准电阻传感器比较 -196 °C CMC 0,32 °C TP44.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be66e83569301eb029715f09","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy","test_object_en":"Direct indicating thermometers and temperature measuring chains, electronic and analogue thermometers, resistance thermometers, thermoelectric thermometers and thermocouples","test_object_zh":"直读式温度计和温度测量链、电子和模拟温度计、电阻温度计、热电温度计和热电偶","test_object_cs":"Přímo ukazující teploměry a měřicí řetězce teploty, elektronické a analogové teploměry, odporové teploměry, termoelektrické teploměry a termočlánky","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -30 °C","cmc":"0,20 °C"},{"name":"","range":"od -30 °C do 0 °C","cmc":"0,07 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"0,04 °C"},{"name":"","range":"od 50 °C do 140 °C","cmc":"0,06 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -30 °C","cmc":"0,20 °C"},{"name":"","range":"-30 °C to 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"0,04 °C"},{"name":"","range":"50 °C to 140 °C","cmc":"0,06 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -30 °C","cmc":"0,20 °C"},{"name":"","range":"-30 °C 至 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"0,04 °C"},{"name":"","range":"50 °C 至 140 °C","cmc":"0,06 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -30 °C","cmc":"0,20 °C"},{"name":"","range":"-30 °C až 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"0,04 °C"},{"name":"","range":"50 °C až 140 °C","cmc":"0,06 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a standard resistance sensor in liquid bath","technique_zh":"在液体槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kapalinové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a standard resistance sensor in liquid bath"],"techniques_zh":["在液体槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -30 °C CMC 0,20 °C\nod -30 °C do 0 °C CMC 0,07 °C\nod 0 °C do 50 °C CMC 0,04 °C\nod 50 °C do 140 °C CMC 0,06 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","reference":"TP44.1","norm_bases":["TP44.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej od -80 °C do -30 °C CMC 0,20 °C od -30 °C do 0 °C CMC 0,07 °C od 0 °C do 50 °C CMC 0,04 °C od 50 °C do 140 °C CMC 0,06 °C Přímo ukazující teploměry a měřicí řetězce teploty, elektronické a analogové teploměry, odporové teploměry, termoelektrické teploměry a termočlánky Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kapalinové lázni -80 °C až -30 °C CMC 0,20 °C -30 °C až 0 °C CMC 0,07 °C 0 °C až 50 °C CMC 0,04 °C 50 °C až 140 °C CMC 0,06 °C TP44.1 Termometry bezposrednio wskazujace i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni cieczowej od -80 °C do -30 °C CMC 0,20 °C od -30 °C do 0 °C CMC 0,07 °C od 0 °C do 50 °C CMC 0,04 °C od 50 °C do 140 °C CMC 0,06 °C Primo ukazujici teplomery a merici retezce teploty, elektronicke a analogove teplomery, odporove teplomery, termoelektricke teplomery a termoclanky Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kapalinove lazni -80 °C az -30 °C CMC 0,20 °C -30 °C az 0 °C CMC 0,07 °C 0 °C az 50 °C CMC 0,04 °C 50 °C az 140 °C CMC 0,06 °C TP44.1","search_en":"Direct indicating thermometers and temperature measuring chains, electronic and analogue thermometers, resistance thermometers, thermoelectric thermometers and thermocouples Calibration – temperature Comparison with a standard resistance sensor in liquid bath -80 °C to -30 °C CMC 0,20 °C -30 °C to 0 °C CMC 0,07 °C 0 °C to 50 °C CMC 0,04 °C 50 °C to 140 °C CMC 0,06 °C TP44.1","search_zh":"直读式温度计和温度测量链、电子和模拟温度计、电阻温度计、热电温度计和热电偶 校准 – 温度 在液体槽中与标准电阻传感器比较 -80 °C 至 -30 °C CMC 0,20 °C -30 °C 至 0 °C CMC 0,07 °C 0 °C 至 50 °C CMC 0,04 °C 50 °C 至 140 °C CMC 0,06 °C TP44.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bcef2c83c50cefa88574f8b","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Termometry bezpośrednio wskazujące i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy","test_object_en":"Direct indicating thermometers and temperature measuring chains, electronic and analogue thermometers, resistance thermometers, thermoelectric thermometers and thermocouples","test_object_zh":"直读式温度计和温度测量链、电子和模拟温度计、电阻温度计、热电温度计和热电偶","test_object_cs":"Přímo ukazující teploměry a měřicí řetězce teploty, elektronické a analogové teploměry, odporové teploměry, termoelektrické teploměry a termočlánky","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 140 °C do 300 °C","cmc":"0,34 °C"},{"name":"","range":"od 300 °C do 600 °C","cmc":"0,62 °C"},{"name":"","range":"od 600 °C do 1000 °C","cmc":"3,5 °C"}],"parameters_en":[{"name":"","range":"140 °C to 300 °C","cmc":"0,34 °C"},{"name":"","range":"300 °C to 600 °C","cmc":"0,62 °C"},{"name":"","range":"600 °C to 1000 °C","cmc":"3,5 °C"}],"parameters_zh":[{"name":"","range":"140 °C 至 300 °C","cmc":"0,34 °C"},{"name":"","range":"300 °C 至 600 °C","cmc":"0,62 °C"},{"name":"","range":"600 °C 至 1000 °C","cmc":"3,5 °C"}],"parameters_cs":[{"name":"","range":"140 °C až 300 °C","cmc":"0,34 °C"},{"name":"","range":"300 °C až 600 °C","cmc":"0,62 °C"},{"name":"","range":"600 °C až 1000 °C","cmc":"3,5 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym","technique_en":"Comparison with a standard resistance sensor in a calibrating oven","technique_zh":"在校准炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kalibrační pícce","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym"],"techniques_en":["Comparison with a standard resistance sensor in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 140 °C do 300 °C CMC 0,34 °C\nod 300 °C do 600 °C CMC 0,62 °C\nod 600 °C do 1000 °C CMC 3,5 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym","reference":"TP44.1","norm_bases":["TP44.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym od 140 °C do 300 °C CMC 0,34 °C od 300 °C do 600 °C CMC 0,62 °C od 600 °C do 1000 °C CMC 3,5 °C Přímo ukazující teploměry a měřicí řetězce teploty, elektronické a analogové teploměry, odporové teploměry, termoelektrické teploměry a termočlánky Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kalibrační pícce 140 °C až 300 °C CMC 0,34 °C 300 °C až 600 °C CMC 0,62 °C 600 °C až 1000 °C CMC 3,5 °C TP44.1 Termometry bezposrednio wskazujace i tory pomiarowe temperatury, termometry elektroniczne i analogowe, termometry rezystancyjne, termometry termoelektryczne i termoelementy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcujacym od 140 °C do 300 °C CMC 0,34 °C od 300 °C do 600 °C CMC 0,62 °C od 600 °C do 1000 °C CMC 3,5 °C Primo ukazujici teplomery a merici retezce teploty, elektronicke a analogove teplomery, odporove teplomery, termoelektricke teplomery a termoclanky Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kalibracni picce 140 °C az 300 °C CMC 0,34 °C 300 °C az 600 °C CMC 0,62 °C 600 °C az 1000 °C CMC 3,5 °C TP44.1","search_en":"Direct indicating thermometers and temperature measuring chains, electronic and analogue thermometers, resistance thermometers, thermoelectric thermometers and thermocouples Calibration – temperature Comparison with a standard resistance sensor in a calibrating oven 140 °C to 300 °C CMC 0,34 °C 300 °C to 600 °C CMC 0,62 °C 600 °C to 1000 °C CMC 3,5 °C TP44.1","search_zh":"直读式温度计和温度测量链、电子和模拟温度计、电阻温度计、热电温度计和热电偶 校准 – 温度 在校准炉中与标准电阻传感器比较 140 °C 至 300 °C CMC 0,34 °C 300 °C 至 600 °C CMC 0,62 °C 600 °C 至 1000 °C CMC 3,5 °C TP44.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a215972db0991471d3f6009","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"2","test_object":"Rezystancyjne czujniki temperatury, termometry rezystancyjne","test_object_en":"Resistance temperature sensors, resistance thermometers","test_object_zh":"电阻式温度传感器、电阻温度计","test_object_cs":"Odporové snímače teploty, odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"0,3 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"0,3 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"0,3 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem","technique_en":"Comparison with a standard resistance sensor in a nitrogen vessel","technique_zh":"在液氮容器中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem"],"techniques_en":["Comparison with a standard resistance sensor in a nitrogen vessel"],"techniques_zh":["在液氮容器中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n-196 °C CMC 0,3 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem","reference":"TP44.2","norm_bases":["TP44.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury, termometry rezystancyjne Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem -196 °C CMC 0,3 °C Odporové snímače teploty, odporové teploměry Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem -196 °C CMC 0,3 °C TP44.2 Rezystancyjne czujniki temperatury, termometry rezystancyjne Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem -196 °C CMC 0,3 °C Odporove snimace teploty, odporove teplomery Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v nadobe s dusikem -196 °C CMC 0,3 °C TP44.2","search_en":"Resistance temperature sensors, resistance thermometers Calibration – temperature Comparison with a standard resistance sensor in a nitrogen vessel -196 °C CMC 0,3 °C TP44.2","search_zh":"电阻式温度传感器、电阻温度计 校准 – 温度 在液氮容器中与标准电阻传感器比较 -196 °C CMC 0,3 °C TP44.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1eb8db84daffcc0fdf2e583c","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"2","test_object":"Rezystancyjne czujniki temperatury, termometry rezystancyjne","test_object_en":"Resistance temperature sensors, resistance thermometers","test_object_zh":"电阻式温度传感器、电阻温度计","test_object_cs":"Odporové snímače teploty, odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -30 °C","cmc":"0,15 °C"},{"name":"","range":"od -30 °C do 0 °C","cmc":"0,07 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"0,03 °C"},{"name":"","range":"od 50 °C do 140 °C","cmc":"0,06 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -30 °C","cmc":"0,15 °C"},{"name":"","range":"-30 °C to 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C to 140 °C","cmc":"0,06 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -30 °C","cmc":"0,15 °C"},{"name":"","range":"-30 °C 至 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C 至 140 °C","cmc":"0,06 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -30 °C","cmc":"0,15 °C"},{"name":"","range":"-30 °C až 0 °C","cmc":"0,07 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"0,03 °C"},{"name":"","range":"50 °C až 140 °C","cmc":"0,06 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a standard resistance sensor in liquid bath","technique_zh":"在液体槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kapalinové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a standard resistance sensor in liquid bath"],"techniques_zh":["在液体槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -30 °C CMC 0,15 °C\nod -30 °C do 0 °C CMC 0,07 °C\nod 0 °C do 50 °C CMC 0,03 °C\nod 50 °C do 140 °C CMC 0,06 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","reference":"TP44.2","norm_bases":["TP44.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury, termometry rezystancyjne Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej od -80 °C do -30 °C CMC 0,15 °C od -30 °C do 0 °C CMC 0,07 °C od 0 °C do 50 °C CMC 0,03 °C od 50 °C do 140 °C CMC 0,06 °C Odporové snímače teploty, odporové teploměry Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kapalinové lázni -80 °C až -30 °C CMC 0,15 °C -30 °C až 0 °C CMC 0,07 °C 0 °C až 50 °C CMC 0,03 °C 50 °C až 140 °C CMC 0,06 °C TP44.2 Rezystancyjne czujniki temperatury, termometry rezystancyjne Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni cieczowej od -80 °C do -30 °C CMC 0,15 °C od -30 °C do 0 °C CMC 0,07 °C od 0 °C do 50 °C CMC 0,03 °C od 50 °C do 140 °C CMC 0,06 °C Odporove snimace teploty, odporove teplomery Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kapalinove lazni -80 °C az -30 °C CMC 0,15 °C -30 °C az 0 °C CMC 0,07 °C 0 °C az 50 °C CMC 0,03 °C 50 °C az 140 °C CMC 0,06 °C TP44.2","search_en":"Resistance temperature sensors, resistance thermometers Calibration – temperature Comparison with a standard resistance sensor in liquid bath -80 °C to -30 °C CMC 0,15 °C -30 °C to 0 °C CMC 0,07 °C 0 °C to 50 °C CMC 0,03 °C 50 °C to 140 °C CMC 0,06 °C TP44.2","search_zh":"电阻式温度传感器、电阻温度计 校准 – 温度 在液体槽中与标准电阻传感器比较 -80 °C 至 -30 °C CMC 0,15 °C -30 °C 至 0 °C CMC 0,07 °C 0 °C 至 50 °C CMC 0,03 °C 50 °C 至 140 °C CMC 0,06 °C TP44.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cd340c0db9a5cac56c0b99d6","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"2","test_object":"Rezystancyjne czujniki temperatury, termometry rezystancyjne","test_object_en":"Resistance temperature sensors, resistance thermometers","test_object_zh":"电阻式温度传感器、电阻温度计","test_object_cs":"Odporové snímače teploty, odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 140 °C do 300 °C","cmc":"0,26 °C"},{"name":"","range":"od 300 °C do 600 °C","cmc":"0,5 °C"},{"name":"","range":"od 600 °C do 1000 °C","cmc":"3,5 °C"}],"parameters_en":[{"name":"","range":"140 °C to 300 °C","cmc":"0,26 °C"},{"name":"","range":"300 °C to 600 °C","cmc":"0,5 °C"},{"name":"","range":"600 °C to 1000 °C","cmc":"3,5 °C"}],"parameters_zh":[{"name":"","range":"140 °C 至 300 °C","cmc":"0,26 °C"},{"name":"","range":"300 °C 至 600 °C","cmc":"0,5 °C"},{"name":"","range":"600 °C 至 1000 °C","cmc":"3,5 °C"}],"parameters_cs":[{"name":"","range":"140 °C až 300 °C","cmc":"0,26 °C"},{"name":"","range":"300 °C až 600 °C","cmc":"0,5 °C"},{"name":"","range":"600 °C až 1000 °C","cmc":"3,5 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym","technique_en":"Comparison with a standard resistance sensor in a calibrating oven","technique_zh":"在校准炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kalibrační pícce","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym"],"techniques_en":["Comparison with a standard resistance sensor in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 140 °C do 300 °C CMC 0,26 °C\nod 300 °C do 600 °C CMC 0,5 °C\nod 600 °C do 1000 °C CMC 3,5 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym","reference":"TP44.2","norm_bases":["TP44.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury, termometry rezystancyjne Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym od 140 °C do 300 °C CMC 0,26 °C od 300 °C do 600 °C CMC 0,5 °C od 600 °C do 1000 °C CMC 3,5 °C Odporové snímače teploty, odporové teploměry Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kalibrační pícce 140 °C až 300 °C CMC 0,26 °C 300 °C až 600 °C CMC 0,5 °C 600 °C až 1000 °C CMC 3,5 °C TP44.2 Rezystancyjne czujniki temperatury, termometry rezystancyjne Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcujacym od 140 °C do 300 °C CMC 0,26 °C od 300 °C do 600 °C CMC 0,5 °C od 600 °C do 1000 °C CMC 3,5 °C Odporove snimace teploty, odporove teplomery Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kalibracni picce 140 °C az 300 °C CMC 0,26 °C 300 °C az 600 °C CMC 0,5 °C 600 °C az 1000 °C CMC 3,5 °C TP44.2","search_en":"Resistance temperature sensors, resistance thermometers Calibration – temperature Comparison with a standard resistance sensor in a calibrating oven 140 °C to 300 °C CMC 0,26 °C 300 °C to 600 °C CMC 0,5 °C 600 °C to 1000 °C CMC 3,5 °C TP44.2","search_zh":"电阻式温度传感器、电阻温度计 校准 – 温度 在校准炉中与标准电阻传感器比较 140 °C 至 300 °C CMC 0,26 °C 300 °C 至 600 °C CMC 0,5 °C 600 °C 至 1000 °C CMC 3,5 °C TP44.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f091130a49ec944d75d65beb","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"3","test_object":"Ogniwa termoelektryczne, termoelementy","test_object_en":"Thermoelectric cells, thermocouples","test_object_zh":"热电元件、热电偶","test_object_cs":"Termoelektrické články, termočlánky","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"-196 °C","cmc":"4,0 °C"}],"parameters_en":[{"name":"","range":"-196 °C","cmc":"4,0 °C"}],"parameters_zh":[{"name":"","range":"-196 °C","cmc":"4,0 °C"}],"parameters_cs":[{"name":"","range":"-196 °C","cmc":"4,0 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem","technique_en":"Comparison with a standard resistance sensor in a nitrogen vessel","technique_zh":"在液氮容器中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem"],"techniques_en":["Comparison with a standard resistance sensor in a nitrogen vessel"],"techniques_zh":["在液氮容器中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n-196 °C CMC 4,0 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem","reference":"TP44.3","norm_bases":["TP44.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ogniwa termoelektryczne, termoelementy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem -196 °C CMC 4,0 °C Termoelektrické články, termočlánky Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v nádobě s dusíkem -196 °C CMC 4,0 °C TP44.3 Ogniwa termoelektryczne, termoelementy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w naczyniu z azotem -196 °C CMC 4,0 °C Termoelektricke clanky, termoclanky Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v nadobe s dusikem -196 °C CMC 4,0 °C TP44.3","search_en":"Thermoelectric cells, thermocouples Calibration – temperature Comparison with a standard resistance sensor in a nitrogen vessel -196 °C CMC 4,0 °C TP44.3","search_zh":"热电元件、热电偶 校准 – 温度 在液氮容器中与标准电阻传感器比较 -196 °C CMC 4,0 °C TP44.3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ae888cb16e012a0cbe157391","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"3","test_object":"Ogniwa termoelektryczne, termoelementy","test_object_en":"Thermoelectric cells, thermocouples","test_object_zh":"热电元件、热电偶","test_object_cs":"Termoelektrické články, termočlánky","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -30 °C","cmc":"1,5 °C"},{"name":"","range":"od -30 °C do 0 °C","cmc":"0,9 °C"},{"name":"","range":"0 °C","cmc":"0,7 °C"},{"name":"","range":"od 0 °C do 140 °C","cmc":"0,8 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -30 °C","cmc":"1,5 °C"},{"name":"","range":"-30 °C to 0 °C","cmc":"0,9 °C"},{"name":"","range":"0 °C","cmc":"0,7 °C"},{"name":"","range":"0 °C to 140 °C","cmc":"0,8 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -30 °C","cmc":"1,5 °C"},{"name":"","range":"-30 °C 至 0 °C","cmc":"0,9 °C"},{"name":"","range":"0 °C","cmc":"0,7 °C"},{"name":"","range":"0 °C 至 140 °C","cmc":"0,8 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -30 °C","cmc":"1,5 °C"},{"name":"","range":"-30 °C až 0 °C","cmc":"0,9 °C"},{"name":"","range":"0 °C","cmc":"0,7 °C"},{"name":"","range":"0 °C až 140 °C","cmc":"0,8 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a standard resistance sensor in liquid bath","technique_zh":"在液体槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kapalinové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a standard resistance sensor in liquid bath"],"techniques_zh":["在液体槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -30 °C CMC 1,5 °C\nod -30 °C do 0 °C CMC 0,9 °C\n0 °C CMC 0,7 °C\nod 0 °C do 140 °C CMC 0,8 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej","reference":"TP44.3","norm_bases":["TP44.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ogniwa termoelektryczne, termoelementy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni cieczowej od -80 °C do -30 °C CMC 1,5 °C od -30 °C do 0 °C CMC 0,9 °C 0 °C CMC 0,7 °C od 0 °C do 140 °C CMC 0,8 °C Termoelektrické články, termočlánky Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kapalinové lázni -80 °C až -30 °C CMC 1,5 °C -30 °C až 0 °C CMC 0,9 °C 0 °C CMC 0,7 °C 0 °C až 140 °C CMC 0,8 °C TP44.3 Ogniwa termoelektryczne, termoelementy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni cieczowej od -80 °C do -30 °C CMC 1,5 °C od -30 °C do 0 °C CMC 0,9 °C 0 °C CMC 0,7 °C od 0 °C do 140 °C CMC 0,8 °C Termoelektricke clanky, termoclanky Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kapalinove lazni -80 °C az -30 °C CMC 1,5 °C -30 °C az 0 °C CMC 0,9 °C 0 °C CMC 0,7 °C 0 °C az 140 °C CMC 0,8 °C TP44.3","search_en":"Thermoelectric cells, thermocouples Calibration – temperature Comparison with a standard resistance sensor in liquid bath -80 °C to -30 °C CMC 1,5 °C -30 °C to 0 °C CMC 0,9 °C 0 °C CMC 0,7 °C 0 °C to 140 °C CMC 0,8 °C TP44.3","search_zh":"热电元件、热电偶 校准 – 温度 在液体槽中与标准电阻传感器比较 -80 °C 至 -30 °C CMC 1,5 °C -30 °C 至 0 °C CMC 0,9 °C 0 °C CMC 0,7 °C 0 °C 至 140 °C CMC 0,8 °C TP44.3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ea44846d5f032a88f57c4e8","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"3","test_object":"Ogniwa termoelektryczne, termoelementy","test_object_en":"Thermoelectric cells, thermocouples","test_object_zh":"热电元件、热电偶","test_object_cs":"Termoelektrické články, termočlánky","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 140 °C do 300 °C","cmc":"1,5 °C"},{"name":"","range":"od 300 °C do 600 °C","cmc":"1,7 °C"},{"name":"","range":"od 600 °C do 1000 °C","cmc":"3,5 °C"}],"parameters_en":[{"name":"","range":"140 °C to 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C to 600 °C","cmc":"1,7 °C"},{"name":"","range":"600 °C to 1000 °C","cmc":"3,5 °C"}],"parameters_zh":[{"name":"","range":"140 °C 至 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C 至 600 °C","cmc":"1,7 °C"},{"name":"","range":"600 °C 至 1000 °C","cmc":"3,5 °C"}],"parameters_cs":[{"name":"","range":"140 °C až 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C až 600 °C","cmc":"1,7 °C"},{"name":"","range":"600 °C až 1000 °C","cmc":"3,5 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym","technique_en":"Comparison with a standard resistance sensor in a calibrating oven","technique_zh":"在校准炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kalibrační pícce","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym"],"techniques_en":["Comparison with a standard resistance sensor in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 140 °C do 300 °C CMC 1,5 °C\nod 300 °C do 600 °C CMC 1,7 °C\nod 600 °C do 1000 °C CMC 3,5 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym","reference":"TP44.3","norm_bases":["TP44.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ogniwa termoelektryczne, termoelementy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcującym od 140 °C do 300 °C CMC 1,5 °C od 300 °C do 600 °C CMC 1,7 °C od 600 °C do 1000 °C CMC 3,5 °C Termoelektrické články, termočlánky Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kalibrační pícce 140 °C až 300 °C CMC 1,5 °C 300 °C až 600 °C CMC 1,7 °C 600 °C až 1000 °C CMC 3,5 °C TP44.3 Ogniwa termoelektryczne, termoelementy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu wzorcujacym od 140 °C do 300 °C CMC 1,5 °C od 300 °C do 600 °C CMC 1,7 °C od 600 °C do 1000 °C CMC 3,5 °C Termoelektricke clanky, termoclanky Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kalibracni picce 140 °C az 300 °C CMC 1,5 °C 300 °C az 600 °C CMC 1,7 °C 600 °C az 1000 °C CMC 3,5 °C TP44.3","search_en":"Thermoelectric cells, thermocouples Calibration – temperature Comparison with a standard resistance sensor in a calibrating oven 140 °C to 300 °C CMC 1,5 °C 300 °C to 600 °C CMC 1,7 °C 600 °C to 1000 °C CMC 3,5 °C TP44.3","search_zh":"热电元件、热电偶 校准 – 温度 在校准炉中与标准电阻传感器比较 140 °C 至 300 °C CMC 1,5 °C 300 °C 至 600 °C CMC 1,7 °C 600 °C 至 1000 °C CMC 3,5 °C TP44.3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2210e0b105f3387647567793","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"4","test_object":"Termometry bezkontaktowe i tory pomiarowe termometrów bezkontaktowych, kamery termowizyjne, termometry na podczerwień","test_object_en":"Non-contact thermometers and measuring chains of non-contact thermometers, thermal cameras, infrared thermometers","test_object_zh":"非接触式温度计及其测量链、热像仪、红外温度计","test_object_cs":"Bezdotykové teploměry a měřicí řetězce bezdotykových teploměrů, termokamery, infračervené teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -25 °C do 0 °C","cmc":"1,9 °C"},{"name":"","range":"od 0 °C do 50 °C","cmc":"1,3 °C"},{"name":"","range":"od 50 °C do 100 °C","cmc":"1,6 °C"},{"name":"","range":"od 100 °C do 300 °C","cmc":"2,0 °C"},{"name":"","range":"od 300 °C do 500 °C","cmc":"2,5 °C"}],"parameters_en":[{"name":"","range":"-25 °C to 0 °C","cmc":"1,9 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"1,3 °C"},{"name":"","range":"50 °C to 100 °C","cmc":"1,6 °C"},{"name":"","range":"100 °C to 300 °C","cmc":"2,0 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"2,5 °C"}],"parameters_zh":[{"name":"","range":"-25 °C 至 0 °C","cmc":"1,9 °C"},{"name":"","range":"0 °C 至 50 °C","cmc":"1,3 °C"},{"name":"","range":"50 °C 至 100 °C","cmc":"1,6 °C"},{"name":"","range":"100 °C 至 300 °C","cmc":"2,0 °C"},{"name":"","range":"300 °C 至 500 °C","cmc":"2,5 °C"}],"parameters_cs":[{"name":"","range":"-25 °C až 0 °C","cmc":"1,9 °C"},{"name":"","range":"0 °C až 50 °C","cmc":"1,3 °C"},{"name":"","range":"50 °C až 100 °C","cmc":"1,6 °C"},{"name":"","range":"100 °C až 300 °C","cmc":"2,0 °C"},{"name":"","range":"300 °C až 500 °C","cmc":"2,5 °C"}],"technique":"Porównanie z wzorcowym ciałem czarnym","technique_en":"Comparison with a reference black body","technique_zh":"与标准黑体比较","technique_cs":"Porovnání s etalonovým černým tělesem","techniques":["Porównanie z wzorcowym ciałem czarnym"],"techniques_en":["Comparison with a reference black body"],"techniques_zh":["与标准黑体比较"],"techniques_cs":["Porovnání s etalonovým černým tělesem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -25 °C do 0 °C CMC 1,9 °C\nod 0 °C do 50 °C CMC 1,3 °C\nod 50 °C do 100 °C CMC 1,6 °C\nod 100 °C do 300 °C CMC 2,0 °C\nod 300 °C do 500 °C CMC 2,5 °C\nPorównanie z wzorcowym ciałem czarnym","reference":"TP44.4, TP44.5","norm_bases":["TP44.4","TP44.5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezkontaktowe i tory pomiarowe termometrów bezkontaktowych, kamery termowizyjne, termometry na podczerwień Wzorcowanie – temperatura Porównanie z wzorcowym ciałem czarnym od -25 °C do 0 °C CMC 1,9 °C od 0 °C do 50 °C CMC 1,3 °C od 50 °C do 100 °C CMC 1,6 °C od 100 °C do 300 °C CMC 2,0 °C od 300 °C do 500 °C CMC 2,5 °C Bezdotykové teploměry a měřicí řetězce bezdotykových teploměrů, termokamery, infračervené teploměry Kalibrace – teplota Porovnání s etalonovým černým tělesem -25 °C až 0 °C CMC 1,9 °C 0 °C až 50 °C CMC 1,3 °C 50 °C až 100 °C CMC 1,6 °C 100 °C až 300 °C CMC 2,0 °C 300 °C až 500 °C CMC 2,5 °C TP44.4, TP44.5 Termometry bezkontaktowe i tory pomiarowe termometrow bezkontaktowych, kamery termowizyjne, termometry na podczerwien Wzorcowanie – temperatura Porownanie z wzorcowym cialem czarnym od -25 °C do 0 °C CMC 1,9 °C od 0 °C do 50 °C CMC 1,3 °C od 50 °C do 100 °C CMC 1,6 °C od 100 °C do 300 °C CMC 2,0 °C od 300 °C do 500 °C CMC 2,5 °C Bezdotykove teplomery a merici retezce bezdotykovych teplomeru, termokamery, infracervene teplomery Kalibrace – teplota Porovnani s etalonovym cernym telesem -25 °C az 0 °C CMC 1,9 °C 0 °C az 50 °C CMC 1,3 °C 50 °C az 100 °C CMC 1,6 °C 100 °C az 300 °C CMC 2,0 °C 300 °C az 500 °C CMC 2,5 °C TP44.4, TP44.5","search_en":"Non-contact thermometers and measuring chains of non-contact thermometers, thermal cameras, infrared thermometers Calibration – temperature Comparison with a reference black body -25 °C to 0 °C CMC 1,9 °C 0 °C to 50 °C CMC 1,3 °C 50 °C to 100 °C CMC 1,6 °C 100 °C to 300 °C CMC 2,0 °C 300 °C to 500 °C CMC 2,5 °C TP44.4, TP44.5","search_zh":"非接触式温度计及其测量链、热像仪、红外温度计 校准 – 温度 与标准黑体比较 -25 °C 至 0 °C CMC 1,9 °C 0 °C 至 50 °C CMC 1,3 °C 50 °C 至 100 °C CMC 1,6 °C 100 °C 至 300 °C CMC 2,0 °C 300 °C 至 500 °C CMC 2,5 °C TP44.4, TP44.5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"10cdcc035750c4055cef84b5","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"5","test_object":"Temperatura / Wzorcowanie części elektrycznej symulatorów temperatury, części elektrycznej przyrządów do pomiaru temperatury za pomocą termoelementów","test_object_en":"Temperature / Calibration of electrical part of temperature simulators, electrical parts of temperature gauges using thermocouples","test_object_zh":"温度 / 温度模拟器电气部分、使用热电偶的温度测量仪器电气部分的校准","test_object_cs":"Teplota / Kalibrace elektrické části simulátorů teploty, elektrické části měřidel teploty pomocí termočlánků","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Termoelement typu B","range":"od 250 °C do 300 °C","cmc":"0,40 °C"},{"name":"Termoelement typu B","range":"od 300 °C do 400 °C","cmc":"0,33 °C"},{"name":"Termoelement typu B","range":"od 400 °C do 500 °C","cmc":"0,25 °C"},{"name":"Termoelement typu B","range":"od 500 °C do 600 °C","cmc":"0,20 °C"},{"name":"Termoelement typu B","range":"od 600 °C do 700 °C","cmc":"0,17 °C"},{"name":"Termoelement typu B","range":"od 700 °C do 1820 °C","cmc":"0,15 °C"},{"name":"Termoelement typu C","range":"od 0 °C do 2000 °C","cmc":"0,08 °C"},{"name":"Termoelement typu C","range":"od 2000 °C do 2315 °C","cmc":"0,11 °C"},{"name":"Termoelement typu E","range":"od -200 °C do 1000 °C","cmc":"0,05 °C"},{"name":"Termoelement typu J","range":"od -210 °C do -100 °C","cmc":"0,06 °C"},{"name":"Termoelement typu J","range":"od -100 °C do 1200 °C","cmc":"0,05 °C"},{"name":"Termoelement typu K","range":"od -200 °C do -100 °C","cmc":"0,07 °C"},{"name":"Termoelement typu K","range":"od -100 °C do 1300 °C","cmc":"0,06 °C"},{"name":"Termoelement typu N","range":"od -200 °C do -100 °C","cmc":"0,11 °C"},{"name":"Termoelement typu N","range":"od -100 °C do 1300 °C","cmc":"0,06 °C"},{"name":"Termoelement typu R","range":"od 0 °C do 50 °C","cmc":"0,20 °C"},{"name":"Termoelement typu R","range":"od 50 °C do 100 °C","cmc":"0,16 °C"},{"name":"Termoelement typu R","range":"od 100 °C do 1768 °C","cmc":"0,14 °C"},{"name":"Termoelement typu S","range":"od -20 °C do 0 °C","cmc":"0,21 °C"},{"name":"Termoelement typu S","range":"od 0 °C do 50 °C","cmc":"0,20 °C"},{"name":"Termoelement typu S","range":"od 50 °C do 1768 °C","cmc":"0,17 °C"},{"name":"Termoelement typu T","range":"od -200 °C do -150 °C","cmc":"0,07 °C"},{"name":"Termoelement typu T","range":"od -150 °C do 400 °C","cmc":"0,05 °C"},{"name":"Termoelement typu A","range":"od 0 °C do 2480 °C","cmc":"0,26 °C"}],"parameters_en":[{"name":"Type B thermocouple","range":"250 °C to 300 °C","cmc":"0,40 °C"},{"name":"Type B thermocouple","range":"300 °C to 400 °C","cmc":"0,33 °C"},{"name":"Type B thermocouple","range":"400 °C to 500 °C","cmc":"0,25 °C"},{"name":"Type B thermocouple","range":"500 °C to 600 °C","cmc":"0,20 °C"},{"name":"Type B thermocouple","range":"600 °C to 700 °C","cmc":"0,17 °C"},{"name":"Type B thermocouple","range":"700 °C to 1820 °C","cmc":"0,15 °C"},{"name":"Type C thermocouple","range":"0 °C to 2000 °C","cmc":"0,08 °C"},{"name":"Type C thermocouple","range":"2000 °C to 2315 °C","cmc":"0,11 °C"},{"name":"Type E thermocouple","range":"-200 °C to 1000 °C","cmc":"0,05 °C"},{"name":"Type J thermocouple","range":"-210 °C to -100 °C","cmc":"0,06 °C"},{"name":"Type J thermocouple","range":"-100 °C to 1200 °C","cmc":"0,05 °C"},{"name":"Type K thermocouple","range":"-200 °C to -100 °C","cmc":"0,07 °C"},{"name":"Type K thermocouple","range":"-100 °C to 1300 °C","cmc":"0,06 °C"},{"name":"Type N thermocouple","range":"-200 °C to -100 °C","cmc":"0,11 °C"},{"name":"Type N thermocouple","range":"-100 °C to 1300 °C","cmc":"0,06 °C"},{"name":"Type R thermocouple","range":"0 °C to 50 °C","cmc":"0,20 °C"},{"name":"Type R thermocouple","range":"50 °C to 100 °C","cmc":"0,16 °C"},{"name":"Type R thermocouple","range":"100 °C to 1768 °C","cmc":"0,14 °C"},{"name":"Type S thermocouple","range":"-20 °C to 0 °C","cmc":"0,21 °C"},{"name":"Type S thermocouple","range":"0 °C to 50 °C","cmc":"0,20 °C"},{"name":"Type S thermocouple","range":"50 °C to 1768 °C","cmc":"0,17 °C"},{"name":"Type T thermocouple","range":"-200 °C to -150 °C","cmc":"0,07 °C"},{"name":"Type T thermocouple","range":"-150 °C to 400 °C","cmc":"0,05 °C"},{"name":"Type A thermocouple","range":"0 °C to 2480 °C","cmc":"0,26 °C"}],"parameters_zh":[{"name":"B 型热电偶","range":"250 °C 至 300 °C","cmc":"0,40 °C"},{"name":"B 型热电偶","range":"300 °C 至 400 °C","cmc":"0,33 °C"},{"name":"B 型热电偶","range":"400 °C 至 500 °C","cmc":"0,25 °C"},{"name":"B 型热电偶","range":"500 °C 至 600 °C","cmc":"0,20 °C"},{"name":"B 型热电偶","range":"600 °C 至 700 °C","cmc":"0,17 °C"},{"name":"B 型热电偶","range":"700 °C 至 1820 °C","cmc":"0,15 °C"},{"name":"C 型热电偶","range":"0 °C 至 2000 °C","cmc":"0,08 °C"},{"name":"C 型热电偶","range":"2000 °C 至 2315 °C","cmc":"0,11 °C"},{"name":"E 型热电偶","range":"-200 °C 至 1000 °C","cmc":"0,05 °C"},{"name":"J 型热电偶","range":"-210 °C 至 -100 °C","cmc":"0,06 °C"},{"name":"J 型热电偶","range":"-100 °C 至 1200 °C","cmc":"0,05 °C"},{"name":"K 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,07 °C"},{"name":"K 型热电偶","range":"-100 °C 至 1300 °C","cmc":"0,06 °C"},{"name":"N 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,11 °C"},{"name":"N 型热电偶","range":"-100 °C 至 1300 °C","cmc":"0,06 °C"},{"name":"R 型热电偶","range":"0 °C 至 50 °C","cmc":"0,20 °C"},{"name":"R 型热电偶","range":"50 °C 至 100 °C","cmc":"0,16 °C"},{"name":"R 型热电偶","range":"100 °C 至 1768 °C","cmc":"0,14 °C"},{"name":"S 型热电偶","range":"-20 °C 至 0 °C","cmc":"0,21 °C"},{"name":"S 型热电偶","range":"0 °C 至 50 °C","cmc":"0,20 °C"},{"name":"S 型热电偶","range":"50 °C 至 1768 °C","cmc":"0,17 °C"},{"name":"T 型热电偶","range":"-200 °C 至 -150 °C","cmc":"0,07 °C"},{"name":"T 型热电偶","range":"-150 °C 至 400 °C","cmc":"0,05 °C"},{"name":"A 型热电偶","range":"0 °C 至 2480 °C","cmc":"0,26 °C"}],"parameters_cs":[{"name":"Termočlánek typu B","range":"250 °C až 300 °C","cmc":"0,40 °C"},{"name":"Termočlánek typu B","range":"300 °C až 400 °C","cmc":"0,33 °C"},{"name":"Termočlánek typu B","range":"400 °C až 500 °C","cmc":"0,25 °C"},{"name":"Termočlánek typu B","range":"500 °C až 600 °C","cmc":"0,20 °C"},{"name":"Termočlánek typu B","range":"600 °C až 700 °C","cmc":"0,17 °C"},{"name":"Termočlánek typu B","range":"700 °C až 1820 °C","cmc":"0,15 °C"},{"name":"Termočlánek typu C","range":"0 °C až 2000 °C","cmc":"0,08 °C"},{"name":"Termočlánek typu C","range":"2000 °C až 2315 °C","cmc":"0,11 °C"},{"name":"Termočlánek typu E","range":"-200 °C až 1000 °C","cmc":"0,05 °C"},{"name":"Termočlánek typu J","range":"-210 °C až -100 °C","cmc":"0,06 °C"},{"name":"Termočlánek typu J","range":"-100 °C až 1200 °C","cmc":"0,05 °C"},{"name":"Termočlánek typu K","range":"-200 °C až -100 °C","cmc":"0,07 °C"},{"name":"Termočlánek typu K","range":"-100 °C až 1300 °C","cmc":"0,06 °C"},{"name":"Termočlánek typu N","range":"-200 °C až -100 °C","cmc":"0,11 °C"},{"name":"Termočlánek typu N","range":"-100 °C až 1300 °C","cmc":"0,06 °C"},{"name":"Termočlánek typu R","range":"0 °C až 50 °C","cmc":"0,20 °C"},{"name":"Termočlánek typu R","range":"50 °C až 100 °C","cmc":"0,16 °C"},{"name":"Termočlánek typu R","range":"100 °C až 1768 °C","cmc":"0,14 °C"},{"name":"Termočlánek typu S","range":"-20 °C až 0 °C","cmc":"0,21 °C"},{"name":"Termočlánek typu S","range":"0 °C až 50 °C","cmc":"0,20 °C"},{"name":"Termočlánek typu S","range":"50 °C až 1768 °C","cmc":"0,17 °C"},{"name":"Termočlánek typu T","range":"-200 °C až -150 °C","cmc":"0,07 °C"},{"name":"Termočlánek typu T","range":"-150 °C až 400 °C","cmc":"0,05 °C"},{"name":"Termočlánek typu A","range":"0 °C až 2480 °C","cmc":"0,26 °C"}],"technique":"Bezpośrednie generowanie kalibratorem i pomiar multimetrem równoważnego napięcia stałego bez wpływu CJC","technique_en":"Direct calibrator generation and multimeter measurement, of equivalent DC voltage without the effect of CJC","technique_zh":"用校准器直接产生并用万用表测量等效直流电压（不含 CJC 影响）","technique_cs":"Přímé generování kalibrátorem a měření multimetrem ekvivalentního stejnosměrného napětí bez vlivu CJC","techniques":["Bezpośrednie generowanie kalibratorem i pomiar multimetrem równoważnego napięcia stałego bez wpływu CJC"],"techniques_en":["Direct calibrator generation and multimeter measurement, of equivalent DC voltage without the effect of CJC"],"techniques_zh":["用校准器直接产生并用万用表测量等效直流电压（不含 CJC 影响）"],"techniques_cs":["Přímé generování kalibrátorem a měření multimetrem ekvivalentního stejnosměrného napětí bez vlivu CJC"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nTermoelement typu B od 250 °C do 300 °C CMC 0,40 °C\nTermoelement typu B od 300 °C do 400 °C CMC 0,33 °C\nTermoelement typu B od 400 °C do 500 °C CMC 0,25 °C\nTermoelement typu B od 500 °C do 600 °C CMC 0,20 °C\nTermoelement typu B od 600 °C do 700 °C CMC 0,17 °C\nTermoelement typu B od 700 °C do 1820 °C CMC 0,15 °C\nTermoelement typu C od 0 °C do 2000 °C CMC 0,08 °C\nTermoelement typu C od 2000 °C do 2315 °C CMC 0,11 °C\nTermoelement typu E od -200 °C do 1000 °C CMC 0,05 °C\nTermoelement typu J od -210 °C do -100 °C CMC 0,06 °C\nTermoelement typu J od -100 °C do 1200 °C CMC 0,05 °C\nTermoelement typu K od -200 °C do -100 °C CMC 0,07 °C\nTermoelement typu K od -100 °C do 1300 °C CMC 0,06 °C\nTermoelement typu N od -200 °C do -100 °C CMC 0,11 °C\nTermoelement typu N od -100 °C do 1300 °C CMC 0,06 °C\nTermoelement typu R od 0 °C do 50 °C CMC 0,20 °C\nTermoelement typu R od 50 °C do 100 °C CMC 0,16 °C\nTermoelement typu R od 100 °C do 1768 °C CMC 0,14 °C\nTermoelement typu S od -20 °C do 0 °C CMC 0,21 °C\nTermoelement typu S od 0 °C do 50 °C CMC 0,20 °C\nTermoelement typu S od 50 °C do 1768 °C CMC 0,17 °C\nTermoelement typu T od -200 °C do -150 °C CMC 0,07 °C\nTermoelement typu T od -150 °C do 400 °C CMC 0,05 °C\nTermoelement typu A od 0 °C do 2480 °C CMC 0,26 °C\nBezpośrednie generowanie kalibratorem i pomiar multimetrem równoważnego napięcia stałego bez wpływu CJC","reference":"TP1, TP21","norm_bases":["TP1","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura / Wzorcowanie części elektrycznej symulatorów temperatury, części elektrycznej przyrządów do pomiaru temperatury za pomocą termoelementów Wzorcowanie – temperatura Bezpośrednie generowanie kalibratorem i pomiar multimetrem równoważnego napięcia stałego bez wpływu CJC Termoelement typu B od 250 °C do 300 °C CMC 0,40 °C Termoelement typu B od 300 °C do 400 °C CMC 0,33 °C Termoelement typu B od 400 °C do 500 °C CMC 0,25 °C Termoelement typu B od 500 °C do 600 °C CMC 0,20 °C Termoelement typu B od 600 °C do 700 °C CMC 0,17 °C Termoelement typu B od 700 °C do 1820 °C CMC 0,15 °C Termoelement typu C od 0 °C do 2000 °C CMC 0,08 °C Termoelement typu C od 2000 °C do 2315 °C CMC 0,11 °C Termoelement typu E od -200 °C do 1000 °C CMC 0,05 °C Termoelement typu J od -210 °C do -100 °C CMC 0,06 °C Termoelement typu J od -100 °C do 1200 °C CMC 0,05 °C Termoelement typu K od -200 °C do -100 °C CMC 0,07 °C Termoelement typu K od -100 °C do 1300 °C CMC 0,06 °C Termoelement typu N od -200 °C do -100 °C CMC 0,11 °C Termoelement typu N od -100 °C do 1300 °C CMC 0,06 °C Termoelement typu R od 0 °C do 50 °C CMC 0,20 °C Termoelement typu R od 50 °C do 100 °C CMC 0,16 °C Termoelement typu R od 100 °C do 1768 °C CMC 0,14 °C Termoelement typu S od -20 °C do 0 °C CMC 0,21 °C Termoelement typu S od 0 °C do 50 °C CMC 0,20 °C Termoelement typu S od 50 °C do 1768 °C CMC 0,17 °C Termoelement typu T od -200 °C do -150 °C CMC 0,07 °C Termoelement typu T od -150 °C do 400 °C CMC 0,05 °C Termoelement typu A od 0 °C do 2480 °C CMC 0,26 °C Teplota / Kalibrace elektrické části simulátorů teploty, elektrické části měřidel teploty pomocí termočlánků Kalibrace – teplota Přímé generování kalibrátorem a měření multimetrem ekvivalentního stejnosměrného napětí bez vlivu CJC Termočlánek typu B 250 °C až 300 °C CMC 0,40 °C Termočlánek typu B 300 °C až 400 °C CMC 0,33 °C Termočlánek typu B 400 °C až 500 °C CMC 0,25 °C Termočlánek typu B 500 °C až 600 °C CMC 0,20 °C Termočlánek typu B 600 °C až 700 °C CMC 0,17 °C Termočlánek typu B 700 °C až 1820 °C CMC 0,15 °C Termočlánek typu C 0 °C až 2000 °C CMC 0,08 °C Termočlánek typu C 2000 °C až 2315 °C CMC 0,11 °C Termočlánek typu E -200 °C až 1000 °C CMC 0,05 °C Termočlánek typu J -210 °C až -100 °C CMC 0,06 °C Termočlánek typu J -100 °C až 1200 °C CMC 0,05 °C Termočlánek typu K -200 °C až -100 °C CMC 0,07 °C Termočlánek typu K -100 °C až 1300 °C CMC 0,06 °C Termočlánek typu N -200 °C až -100 °C CMC 0,11 °C Termočlánek typu N -100 °C až 1300 °C CMC 0,06 °C Termočlánek typu R 0 °C až 50 °C CMC 0,20 °C Termočlánek typu R 50 °C až 100 °C CMC 0,16 °C Termočlánek typu R 100 °C až 1768 °C CMC 0,14 °C Termočlánek typu S -20 °C až 0 °C CMC 0,21 °C Termočlánek typu S 0 °C až 50 °C CMC 0,20 °C Termočlánek typu S 50 °C až 1768 °C CMC 0,17 °C Termočlánek typu T -200 °C až -150 °C CMC 0,07 °C Termočlánek typu T -150 °C až 400 °C CMC 0,05 °C Termočlánek typu A 0 °C až 2480 °C CMC 0,26 °C TP1, TP21 Temperatura / Wzorcowanie czesci elektrycznej symulatorow temperatury, czesci elektrycznej przyrzadow do pomiaru temperatury za pomoca termoelementow Wzorcowanie – temperatura Bezposrednie generowanie kalibratorem i pomiar multimetrem rownowaznego napiecia stalego bez wplywu CJC Termoelement typu B od 250 °C do 300 °C CMC 0,40 °C Termoelement typu B od 300 °C do 400 °C CMC 0,33 °C Termoelement typu B od 400 °C do 500 °C CMC 0,25 °C Termoelement typu B od 500 °C do 600 °C CMC 0,20 °C Termoelement typu B od 600 °C do 700 °C CMC 0,17 °C Termoelement typu B od 700 °C do 1820 °C CMC 0,15 °C Termoelement typu C od 0 °C do 2000 °C CMC 0,08 °C Termoelement typu C od 2000 °C do 2315 °C CMC 0,11 °C Termoelement typu E od -200 °C do 1000 °C CMC 0,05 °C Termoelement typu J od -210 °C do -100 °C CMC 0,06 °C Termoelement typu J od -100 °C do 1200 °C CMC 0,05 °C Termoelement typu K od -200 °C do -100 °C CMC 0,07 °C Termoelement typu K od -100 °C do 1300 °C CMC 0,06 °C Termoelement typu N od -200 °C do -100 °C CMC 0,11 °C Termoelement typu N od -100 °C do 1300 °C CMC 0,06 °C Termoelement typu R od 0 °C do 50 °C CMC 0,20 °C Termoelement typu R od 50 °C do 100 °C CMC 0,16 °C Termoelement typu R od 100 °C do 1768 °C CMC 0,14 °C Termoelement typu S od -20 °C do 0 °C CMC 0,21 °C Termoelement typu S od 0 °C do 50 °C CMC 0,20 °C Termoelement typu S od 50 °C do 1768 °C CMC 0,17 °C Termoelement typu T od -200 °C do -150 °C CMC 0,07 °C Termoelement typu T od -150 °C do 400 °C CMC 0,05 °C Termoelement typu A od 0 °C do 2480 °C CMC 0,26 °C Teplota / Kalibrace elektricke casti simulatoru teploty, elektricke casti meridel teploty pomoci termoclanku Kalibrace – teplota Prime generovani kalibratorem a mereni multimetrem ekvivalentniho stejnosmerneho napeti bez vlivu CJC Termoclanek typu B 250 °C az 300 °C CMC 0,40 °C Termoclanek typu B 300 °C az 400 °C CMC 0,33 °C Termoclanek typu B 400 °C az 500 °C CMC 0,25 °C Termoclanek typu B 500 °C az 600 °C CMC 0,20 °C Termoclanek typu B 600 °C az 700 °C CMC 0,17 °C Termoclanek typu B 700 °C az 1820 °C CMC 0,15 °C Termoclanek typu C 0 °C az 2000 °C CMC 0,08 °C Termoclanek typu C 2000 °C az 2315 °C CMC 0,11 °C Termoclanek typu E -200 °C az 1000 °C CMC 0,05 °C Termoclanek typu J -210 °C az -100 °C CMC 0,06 °C Termoclanek typu J -100 °C az 1200 °C CMC 0,05 °C Termoclanek typu K -200 °C az -100 °C CMC 0,07 °C Termoclanek typu K -100 °C az 1300 °C CMC 0,06 °C Termoclanek typu N -200 °C az -100 °C CMC 0,11 °C Termoclanek typu N -100 °C az 1300 °C CMC 0,06 °C Termoclanek typu R 0 °C az 50 °C CMC 0,20 °C Termoclanek typu R 50 °C az 100 °C CMC 0,16 °C Termoclanek typu R 100 °C az 1768 °C CMC 0,14 °C Termoclanek typu S -20 °C az 0 °C CMC 0,21 °C Termoclanek typu S 0 °C az 50 °C CMC 0,20 °C Termoclanek typu S 50 °C az 1768 °C CMC 0,17 °C Termoclanek typu T -200 °C az -150 °C CMC 0,07 °C Termoclanek typu T -150 °C az 400 °C CMC 0,05 °C Termoclanek typu A 0 °C az 2480 °C CMC 0,26 °C TP1, TP21","search_en":"Temperature / Calibration of electrical part of temperature simulators, electrical parts of temperature gauges using thermocouples Calibration – temperature Direct calibrator generation and multimeter measurement, of equivalent DC voltage without the effect of CJC Type B thermocouple 250 °C to 300 °C CMC 0,40 °C Type B thermocouple 300 °C to 400 °C CMC 0,33 °C Type B thermocouple 400 °C to 500 °C CMC 0,25 °C Type B thermocouple 500 °C to 600 °C CMC 0,20 °C Type B thermocouple 600 °C to 700 °C CMC 0,17 °C Type B thermocouple 700 °C to 1820 °C CMC 0,15 °C Type C thermocouple 0 °C to 2000 °C CMC 0,08 °C Type C thermocouple 2000 °C to 2315 °C CMC 0,11 °C Type E thermocouple -200 °C to 1000 °C CMC 0,05 °C Type J thermocouple -210 °C to -100 °C CMC 0,06 °C Type J thermocouple -100 °C to 1200 °C CMC 0,05 °C Type K thermocouple -200 °C to -100 °C CMC 0,07 °C Type K thermocouple -100 °C to 1300 °C CMC 0,06 °C Type N thermocouple -200 °C to -100 °C CMC 0,11 °C Type N thermocouple -100 °C to 1300 °C CMC 0,06 °C Type R thermocouple 0 °C to 50 °C CMC 0,20 °C Type R thermocouple 50 °C to 100 °C CMC 0,16 °C Type R thermocouple 100 °C to 1768 °C CMC 0,14 °C Type S thermocouple -20 °C to 0 °C CMC 0,21 °C Type S thermocouple 0 °C to 50 °C CMC 0,20 °C Type S thermocouple 50 °C to 1768 °C CMC 0,17 °C Type T thermocouple -200 °C to -150 °C CMC 0,07 °C Type T thermocouple -150 °C to 400 °C CMC 0,05 °C Type A thermocouple 0 °C to 2480 °C CMC 0,26 °C TP1, TP21","search_zh":"温度 / 温度模拟器电气部分、使用热电偶的温度测量仪器电气部分的校准 校准 – 温度 用校准器直接产生并用万用表测量等效直流电压（不含 CJC 影响） B 型热电偶 250 °C 至 300 °C CMC 0,40 °C B 型热电偶 300 °C 至 400 °C CMC 0,33 °C B 型热电偶 400 °C 至 500 °C CMC 0,25 °C B 型热电偶 500 °C 至 600 °C CMC 0,20 °C B 型热电偶 600 °C 至 700 °C CMC 0,17 °C B 型热电偶 700 °C 至 1820 °C CMC 0,15 °C C 型热电偶 0 °C 至 2000 °C CMC 0,08 °C C 型热电偶 2000 °C 至 2315 °C CMC 0,11 °C E 型热电偶 -200 °C 至 1000 °C CMC 0,05 °C J 型热电偶 -210 °C 至 -100 °C CMC 0,06 °C J 型热电偶 -100 °C 至 1200 °C CMC 0,05 °C K 型热电偶 -200 °C 至 -100 °C CMC 0,07 °C K 型热电偶 -100 °C 至 1300 °C CMC 0,06 °C N 型热电偶 -200 °C 至 -100 °C CMC 0,11 °C N 型热电偶 -100 °C 至 1300 °C CMC 0,06 °C R 型热电偶 0 °C 至 50 °C CMC 0,20 °C R 型热电偶 50 °C 至 100 °C CMC 0,16 °C R 型热电偶 100 °C 至 1768 °C CMC 0,14 °C S 型热电偶 -20 °C 至 0 °C CMC 0,21 °C S 型热电偶 0 °C 至 50 °C CMC 0,20 °C S 型热电偶 50 °C 至 1768 °C CMC 0,17 °C T 型热电偶 -200 °C 至 -150 °C CMC 0,07 °C T 型热电偶 -150 °C 至 400 °C CMC 0,05 °C A 型热电偶 0 °C 至 2480 °C CMC 0,26 °C TP1, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"952338f819f9b5964d080982","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"5","test_object":"Temperatura / Wzorcowanie części elektrycznej symulatorów temperatury, części elektrycznej przyrządów do pomiaru temperatury za pomocą termoelementów","test_object_en":"Temperature / Calibration of electrical part of temperature simulators, electrical parts of temperature gauges using thermocouples","test_object_zh":"温度 / 温度模拟器电气部分、使用热电偶的温度测量仪器电气部分的校准","test_object_cs":"Teplota / Kalibrace elektrické části simulátorů teploty, elektrické části měřidel teploty pomocí termočlánků","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"Termoelement typu B","range":"od 600 °C do 800 °C","cmc":"0,44 °C"},{"name":"Termoelement typu B","range":"od 800 °C do 1000 °C","cmc":"0,34 °C"},{"name":"Termoelement typu B","range":"od 1000 °C do 1550 °C","cmc":"0,30 °C"},{"name":"Termoelement typu B","range":"od 1550 °C do 1820 °C","cmc":"0,33 °C"},{"name":"Termoelement typu C","range":"od 0 °C do 150 °C","cmc":"0,30 °C"},{"name":"Termoelement typu C","range":"od 150 °C do 650 °C","cmc":"0,26 °C"},{"name":"Termoelement typu C","range":"od 650 °C do 1000 °C","cmc":"0,31 °C"},{"name":"Termoelement typu C","range":"od 1000 °C do 1800 °C","cmc":"0,50 °C"},{"name":"Termoelement typu C","range":"od 1800 °C do 2316 °C","cmc":"0,84 °C"},{"name":"Termoelement typu E","range":"od -250 °C do -100 °C","cmc":"0,50 °C"},{"name":"Termoelement typu E","range":"od -100 °C do -25 °C","cmc":"0,16 °C"},{"name":"Termoelement typu E","range":"od -25 °C do 350 °C","cmc":"0,14 °C"},{"name":"Termoelement typu E","range":"od 350 °C do 650 °C","cmc":"0,16 °C"},{"name":"Termoelement typu E","range":"od 650 °C do 1000 °C","cmc":"0,21 °C"},{"name":"Termoelement typu J","range":"od -210 °C do -100 °C","cmc":"0,27 °C"},{"name":"Termoelement typu J","range":"od -100 °C do -30 °C","cmc":"0,16 °C"},{"name":"Termoelement typu J","range":"od -30 °C do 150 °C","cmc":"0,14 °C"},{"name":"Termoelement typu J","range":"od 150 °C do 760 °C","cmc":"0,17 °C"},{"name":"Termoelement typu J","range":"od 760 °C do 1200 °C","cmc":"0,23 °C"},{"name":"Termoelement typu K","range":"od -200 °C do -100 °C","cmc":"0,33 °C"},{"name":"Termoelement typu K","range":"od -100 °C do -25 °C","cmc":"0,18 °C"},{"name":"Termoelement typu K","range":"od -25 °C do 120 °C","cmc":"0,16 °C"},{"name":"Termoelement typu K","range":"od 120 °C do 1000 °C","cmc":"0,26 °C"},{"name":"Termoelement typu K","range":"od 1000 °C do 1372 °C","cmc":"0,40 °C"},{"name":"Termoelement typu L","range":"od -200 °C do -100 °C","cmc":"0,37 °C"},{"name":"Termoelement typu L","range":"od -100 °C do 800 °C","cmc":"0,26 °C"},{"name":"Termoelement typu L","range":"od 800 °C do 900 °C","cmc":"0,17 °C"},{"name":"Termoelement typu N","range":"od -200 °C do -100 °C","cmc":"0,40 °C"},{"name":"Termoelement typu N","range":"od -100 °C do -25 °C","cmc":"0,22 °C"},{"name":"Termoelement typu N","range":"od -25 °C do 120 °C","cmc":"0,19 °C"},{"name":"Termoelement typu N","range":"od 120 °C do 410 °C","cmc":"0,18 °C"},{"name":"Termoelement typu N","range":"od 410 °C do 1300 °C","cmc":"0,27 °C"},{"name":"Termoelement typu R","range":"od 0 °C do 250 °C","cmc":"0,57 °C"},{"name":"Termoelement typu R","range":"od 250 °C do 400 °C","cmc":"0,35 °C"},{"name":"Termoelement typu R","range":"od 400 °C do 1000 °C","cmc":"0,33 °C"},{"name":"Termoelement typu R","range":"od 1000 °C do 1767 °C","cmc":"0,40 °C"},{"name":"Termoelement typu S","range":"od 0 °C do 250 °C","cmc":"0,47 °C"},{"name":"Termoelement typu S","range":"od 250 °C do 1000 °C","cmc":"0,36 °C"},{"name":"Termoelement typu S","range":"od 1000 °C do 1400 °C","cmc":"0,37 °C"},{"name":"Termoelement typu S","range":"od 1400 °C do 1767 °C","cmc":"0,46 °C"},{"name":"Termoelement typu T","range":"od -250 °C do -150 °C","cmc":"0,63 °C"},{"name":"Termoelement typu T","range":"od -150 °C do 0 °C","cmc":"0,24 °C"},{"name":"Termoelement typu T","range":"od 0 °C do 120 °C","cmc":"0,16 °C"},{"name":"Termoelement typu T","range":"od 120 °C do 400 °C","cmc":"0,14 °C"},{"name":"Termoelement typu U","range":"od -200 °C do 0 °C","cmc":"0,57 °C"},{"name":"Termoelement typu U","range":"od 0 °C do 600 °C","cmc":"0,27 °C"}],"parameters_en":[{"name":"Type B thermocouple","range":"600 °C to 800 °C","cmc":"0,44 °C"},{"name":"Type B thermocouple","range":"800 °C to 1000 °C","cmc":"0,34 °C"},{"name":"Type B thermocouple","range":"1000 °C to 1550 °C","cmc":"0,30 °C"},{"name":"Type B thermocouple","range":"1550 °C to 1820 °C","cmc":"0,33 °C"},{"name":"Type C thermocouple","range":"0 °C to 150 °C","cmc":"0,30 °C"},{"name":"Type C thermocouple","range":"150 °C to 650 °C","cmc":"0,26 °C"},{"name":"Type C thermocouple","range":"650 °C to 1000 °C","cmc":"0,31 °C"},{"name":"Type C thermocouple","range":"1000 °C to 1800 °C","cmc":"0,50 °C"},{"name":"Type C thermocouple","range":"1800 °C to 2316 °C","cmc":"0,84 °C"},{"name":"Type E thermocouple","range":"-250 °C to -100 °C","cmc":"0,50 °C"},{"name":"Type E thermocouple","range":"-100 °C to -25 °C","cmc":"0,16 °C"},{"name":"Type E thermocouple","range":"-25 °C to 350 °C","cmc":"0,14 °C"},{"name":"Type E thermocouple","range":"350 °C to 650 °C","cmc":"0,16 °C"},{"name":"Type E thermocouple","range":"650 °C to 1000 °C","cmc":"0,21 °C"},{"name":"Type J thermocouple","range":"-210 °C to -100 °C","cmc":"0,27 °C"},{"name":"Type J thermocouple","range":"-100 °C to -30 °C","cmc":"0,16 °C"},{"name":"Type J thermocouple","range":"-30 °C to 150 °C","cmc":"0,14 °C"},{"name":"Type J thermocouple","range":"150 °C to 760 °C","cmc":"0,17 °C"},{"name":"Type J thermocouple","range":"760 °C to 1200 °C","cmc":"0,23 °C"},{"name":"Type K thermocouple","range":"-200 °C to -100 °C","cmc":"0,33 °C"},{"name":"Type K thermocouple","range":"-100 °C to -25 °C","cmc":"0,18 °C"},{"name":"Type K thermocouple","range":"-25 °C to 120 °C","cmc":"0,16 °C"},{"name":"Type K thermocouple","range":"120 °C to 1000 °C","cmc":"0,26 °C"},{"name":"Type K thermocouple","range":"1000 °C to 1372 °C","cmc":"0,40 °C"},{"name":"Type L thermocouple","range":"-200 °C to -100 °C","cmc":"0,37 °C"},{"name":"Type L thermocouple","range":"-100 °C to 800 °C","cmc":"0,26 °C"},{"name":"Type L thermocouple","range":"800 °C to 900 °C","cmc":"0,17 °C"},{"name":"Type N thermocouple","range":"-200 °C to -100 °C","cmc":"0,40 °C"},{"name":"Type N thermocouple","range":"-100 °C to -25 °C","cmc":"0,22 °C"},{"name":"Type N thermocouple","range":"-25 °C to 120 °C","cmc":"0,19 °C"},{"name":"Type N thermocouple","range":"120 °C to 410 °C","cmc":"0,18 °C"},{"name":"Type N thermocouple","range":"410 °C to 1300 °C","cmc":"0,27 °C"},{"name":"Type R thermocouple","range":"0 °C to 250 °C","cmc":"0,57 °C"},{"name":"Type R thermocouple","range":"250 °C to 400 °C","cmc":"0,35 °C"},{"name":"Type R thermocouple","range":"400 °C to 1000 °C","cmc":"0,33 °C"},{"name":"Type R thermocouple","range":"1000 °C to 1767 °C","cmc":"0,40 °C"},{"name":"Type S thermocouple","range":"0 °C to 250 °C","cmc":"0,47 °C"},{"name":"Type S thermocouple","range":"250 °C to 1000 °C","cmc":"0,36 °C"},{"name":"Type S thermocouple","range":"1000 °C to 1400 °C","cmc":"0,37 °C"},{"name":"Type S thermocouple","range":"1400 °C to 1767 °C","cmc":"0,46 °C"},{"name":"Type T thermocouple","range":"-250 °C to -150 °C","cmc":"0,63 °C"},{"name":"Type T thermocouple","range":"-150 °C to 0 °C","cmc":"0,24 °C"},{"name":"Type T thermocouple","range":"0 °C to 120 °C","cmc":"0,16 °C"},{"name":"Type T thermocouple","range":"120 °C to 400 °C","cmc":"0,14 °C"},{"name":"Type U thermocouple","range":"-200 °C to 0 °C","cmc":"0,57 °C"},{"name":"Type U thermocouple","range":"0 °C to 600 °C","cmc":"0,27 °C"}],"parameters_zh":[{"name":"B 型热电偶","range":"600 °C 至 800 °C","cmc":"0,44 °C"},{"name":"B 型热电偶","range":"800 °C 至 1000 °C","cmc":"0,34 °C"},{"name":"B 型热电偶","range":"1000 °C 至 1550 °C","cmc":"0,30 °C"},{"name":"B 型热电偶","range":"1550 °C 至 1820 °C","cmc":"0,33 °C"},{"name":"C 型热电偶","range":"0 °C 至 150 °C","cmc":"0,30 °C"},{"name":"C 型热电偶","range":"150 °C 至 650 °C","cmc":"0,26 °C"},{"name":"C 型热电偶","range":"650 °C 至 1000 °C","cmc":"0,31 °C"},{"name":"C 型热电偶","range":"1000 °C 至 1800 °C","cmc":"0,50 °C"},{"name":"C 型热电偶","range":"1800 °C 至 2316 °C","cmc":"0,84 °C"},{"name":"E 型热电偶","range":"-250 °C 至 -100 °C","cmc":"0,50 °C"},{"name":"E 型热电偶","range":"-100 °C 至 -25 °C","cmc":"0,16 °C"},{"name":"E 型热电偶","range":"-25 °C 至 350 °C","cmc":"0,14 °C"},{"name":"E 型热电偶","range":"350 °C 至 650 °C","cmc":"0,16 °C"},{"name":"E 型热电偶","range":"650 °C 至 1000 °C","cmc":"0,21 °C"},{"name":"J 型热电偶","range":"-210 °C 至 -100 °C","cmc":"0,27 °C"},{"name":"J 型热电偶","range":"-100 °C 至 -30 °C","cmc":"0,16 °C"},{"name":"J 型热电偶","range":"-30 °C 至 150 °C","cmc":"0,14 °C"},{"name":"J 型热电偶","range":"150 °C 至 760 °C","cmc":"0,17 °C"},{"name":"J 型热电偶","range":"760 °C 至 1200 °C","cmc":"0,23 °C"},{"name":"K 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,33 °C"},{"name":"K 型热电偶","range":"-100 °C 至 -25 °C","cmc":"0,18 °C"},{"name":"K 型热电偶","range":"-25 °C 至 120 °C","cmc":"0,16 °C"},{"name":"K 型热电偶","range":"120 °C 至 1000 °C","cmc":"0,26 °C"},{"name":"K 型热电偶","range":"1000 °C 至 1372 °C","cmc":"0,40 °C"},{"name":"L 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,37 °C"},{"name":"L 型热电偶","range":"-100 °C 至 800 °C","cmc":"0,26 °C"},{"name":"L 型热电偶","range":"800 °C 至 900 °C","cmc":"0,17 °C"},{"name":"N 型热电偶","range":"-200 °C 至 -100 °C","cmc":"0,40 °C"},{"name":"N 型热电偶","range":"-100 °C 至 -25 °C","cmc":"0,22 °C"},{"name":"N 型热电偶","range":"-25 °C 至 120 °C","cmc":"0,19 °C"},{"name":"N 型热电偶","range":"120 °C 至 410 °C","cmc":"0,18 °C"},{"name":"N 型热电偶","range":"410 °C 至 1300 °C","cmc":"0,27 °C"},{"name":"R 型热电偶","range":"0 °C 至 250 °C","cmc":"0,57 °C"},{"name":"R 型热电偶","range":"250 °C 至 400 °C","cmc":"0,35 °C"},{"name":"R 型热电偶","range":"400 °C 至 1000 °C","cmc":"0,33 °C"},{"name":"R 型热电偶","range":"1000 °C 至 1767 °C","cmc":"0,40 °C"},{"name":"S 型热电偶","range":"0 °C 至 250 °C","cmc":"0,47 °C"},{"name":"S 型热电偶","range":"250 °C 至 1000 °C","cmc":"0,36 °C"},{"name":"S 型热电偶","range":"1000 °C 至 1400 °C","cmc":"0,37 °C"},{"name":"S 型热电偶","range":"1400 °C 至 1767 °C","cmc":"0,46 °C"},{"name":"T 型热电偶","range":"-250 °C 至 -150 °C","cmc":"0,63 °C"},{"name":"T 型热电偶","range":"-150 °C 至 0 °C","cmc":"0,24 °C"},{"name":"T 型热电偶","range":"0 °C 至 120 °C","cmc":"0,16 °C"},{"name":"T 型热电偶","range":"120 °C 至 400 °C","cmc":"0,14 °C"},{"name":"U 型热电偶","range":"-200 °C 至 0 °C","cmc":"0,57 °C"},{"name":"U 型热电偶","range":"0 °C 至 600 °C","cmc":"0,27 °C"}],"parameters_cs":[{"name":"Termočlánek typu B","range":"600 °C až 800 °C","cmc":"0,44 °C"},{"name":"Termočlánek typu B","range":"800 °C až 1000 °C","cmc":"0,34 °C"},{"name":"Termočlánek typu B","range":"1000 °C až 1550 °C","cmc":"0,30 °C"},{"name":"Termočlánek typu B","range":"1550 °C až 1820 °C","cmc":"0,33 °C"},{"name":"Termočlánek typu C","range":"0 °C až 150 °C","cmc":"0,30 °C"},{"name":"Termočlánek typu C","range":"150 °C až 650 °C","cmc":"0,26 °C"},{"name":"Termočlánek typu C","range":"650 °C až 1000 °C","cmc":"0,31 °C"},{"name":"Termočlánek typu C","range":"1000 °C až 1800 °C","cmc":"0,50 °C"},{"name":"Termočlánek typu C","range":"1800 °C až 2316 °C","cmc":"0,84 °C"},{"name":"Termočlánek typu E","range":"-250 °C až -100 °C","cmc":"0,50 °C"},{"name":"Termočlánek typu E","range":"-100 °C až -25 °C","cmc":"0,16 °C"},{"name":"Termočlánek typu E","range":"-25 °C až 350 °C","cmc":"0,14 °C"},{"name":"Termočlánek typu E","range":"350 °C až 650 °C","cmc":"0,16 °C"},{"name":"Termočlánek typu E","range":"650 °C až 1000 °C","cmc":"0,21 °C"},{"name":"Termočlánek typu J","range":"-210 °C až -100 °C","cmc":"0,27 °C"},{"name":"Termočlánek typu J","range":"-100 °C až -30 °C","cmc":"0,16 °C"},{"name":"Termočlánek typu J","range":"-30 °C až 150 °C","cmc":"0,14 °C"},{"name":"Termočlánek typu J","range":"150 °C až 760 °C","cmc":"0,17 °C"},{"name":"Termočlánek typu J","range":"760 °C až 1200 °C","cmc":"0,23 °C"},{"name":"Termočlánek typu K","range":"-200 °C až -100 °C","cmc":"0,33 °C"},{"name":"Termočlánek typu K","range":"-100 °C až -25 °C","cmc":"0,18 °C"},{"name":"Termočlánek typu K","range":"-25 °C až 120 °C","cmc":"0,16 °C"},{"name":"Termočlánek typu K","range":"120 °C až 1000 °C","cmc":"0,26 °C"},{"name":"Termočlánek typu K","range":"1000 °C až 1372 °C","cmc":"0,40 °C"},{"name":"Termočlánek typu L","range":"-200 °C až -100 °C","cmc":"0,37 °C"},{"name":"Termočlánek typu L","range":"-100 °C až 800 °C","cmc":"0,26 °C"},{"name":"Termočlánek typu L","range":"800 °C až 900 °C","cmc":"0,17 °C"},{"name":"Termočlánek typu N","range":"-200 °C až -100 °C","cmc":"0,40 °C"},{"name":"Termočlánek typu N","range":"-100 °C až -25 °C","cmc":"0,22 °C"},{"name":"Termočlánek typu N","range":"-25 °C až 120 °C","cmc":"0,19 °C"},{"name":"Termočlánek typu N","range":"120 °C až 410 °C","cmc":"0,18 °C"},{"name":"Termočlánek typu N","range":"410 °C až 1300 °C","cmc":"0,27 °C"},{"name":"Termočlánek typu R","range":"0 °C až 250 °C","cmc":"0,57 °C"},{"name":"Termočlánek typu R","range":"250 °C až 400 °C","cmc":"0,35 °C"},{"name":"Termočlánek typu R","range":"400 °C až 1000 °C","cmc":"0,33 °C"},{"name":"Termočlánek typu R","range":"1000 °C až 1767 °C","cmc":"0,40 °C"},{"name":"Termočlánek typu S","range":"0 °C až 250 °C","cmc":"0,47 °C"},{"name":"Termočlánek typu S","range":"250 °C až 1000 °C","cmc":"0,36 °C"},{"name":"Termočlánek typu S","range":"1000 °C až 1400 °C","cmc":"0,37 °C"},{"name":"Termočlánek typu S","range":"1400 °C až 1767 °C","cmc":"0,46 °C"},{"name":"Termočlánek typu T","range":"-250 °C až -150 °C","cmc":"0,63 °C"},{"name":"Termočlánek typu T","range":"-150 °C až 0 °C","cmc":"0,24 °C"},{"name":"Termočlánek typu T","range":"0 °C až 120 °C","cmc":"0,16 °C"},{"name":"Termočlánek typu T","range":"120 °C až 400 °C","cmc":"0,14 °C"},{"name":"Termočlánek typu U","range":"-200 °C až 0 °C","cmc":"0,57 °C"},{"name":"Termočlánek typu U","range":"0 °C až 600 °C","cmc":"0,27 °C"}],"technique":"Bezpośrednie generowanie i pomiar kalibratorem równoważnego napięcia stałego z uwzględnieniem wpływu CJC","technique_en":"Direct calibrator generation and measurement, of equivalent DC voltage including the effect of CJC","technique_zh":"用校准器直接产生和测量等效直流电压（含 CJC 影响）","technique_cs":"Přímé generování a měření kalibrátorem, ekvivalentního stejnosměrného napětí včetně vlivu CJC","techniques":["Bezpośrednie generowanie i pomiar kalibratorem równoważnego napięcia stałego z uwzględnieniem wpływu CJC"],"techniques_en":["Direct calibrator generation and measurement, of equivalent DC voltage including the effect of CJC"],"techniques_zh":["用校准器直接产生和测量等效直流电压（含 CJC 影响）"],"techniques_cs":["Přímé generování a měření kalibrátorem, ekvivalentního stejnosměrného napětí včetně vlivu CJC"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nTermoelement typu B od 600 °C do 800 °C CMC 0,44 °C\nTermoelement typu B od 800 °C do 1000 °C CMC 0,34 °C\nTermoelement typu B od 1000 °C do 1550 °C CMC 0,30 °C\nTermoelement typu B od 1550 °C do 1820 °C CMC 0,33 °C\nTermoelement typu C od 0 °C do 150 °C CMC 0,30 °C\nTermoelement typu C od 150 °C do 650 °C CMC 0,26 °C\nTermoelement typu C od 650 °C do 1000 °C CMC 0,31 °C\nTermoelement typu C od 1000 °C do 1800 °C CMC 0,50 °C\nTermoelement typu C od 1800 °C do 2316 °C CMC 0,84 °C\nTermoelement typu E od -250 °C do -100 °C CMC 0,50 °C\nTermoelement typu E od -100 °C do -25 °C CMC 0,16 °C\nTermoelement typu E od -25 °C do 350 °C CMC 0,14 °C\nTermoelement typu E od 350 °C do 650 °C CMC 0,16 °C\nTermoelement typu E od 650 °C do 1000 °C CMC 0,21 °C\nTermoelement typu J od -210 °C do -100 °C CMC 0,27 °C\nTermoelement typu J od -100 °C do -30 °C CMC 0,16 °C\nTermoelement typu J od -30 °C do 150 °C CMC 0,14 °C\nTermoelement typu J od 150 °C do 760 °C CMC 0,17 °C\nTermoelement typu J od 760 °C do 1200 °C CMC 0,23 °C\nTermoelement typu K od -200 °C do -100 °C CMC 0,33 °C\nTermoelement typu K od -100 °C do -25 °C CMC 0,18 °C\nTermoelement typu K od -25 °C do 120 °C CMC 0,16 °C\nTermoelement typu K od 120 °C do 1000 °C CMC 0,26 °C\nTermoelement typu K od 1000 °C do 1372 °C CMC 0,40 °C\nTermoelement typu L od -200 °C do -100 °C CMC 0,37 °C\nTermoelement typu L od -100 °C do 800 °C CMC 0,26 °C\nTermoelement typu L od 800 °C do 900 °C CMC 0,17 °C\nTermoelement typu N od -200 °C do -100 °C CMC 0,40 °C\nTermoelement typu N od -100 °C do -25 °C CMC 0,22 °C\nTermoelement typu N od -25 °C do 120 °C CMC 0,19 °C\nTermoelement typu N od 120 °C do 410 °C CMC 0,18 °C\nTermoelement typu N od 410 °C do 1300 °C CMC 0,27 °C\nTermoelement typu R od 0 °C do 250 °C CMC 0,57 °C\nTermoelement typu R od 250 °C do 400 °C CMC 0,35 °C\nTermoelement typu R od 400 °C do 1000 °C CMC 0,33 °C\nTermoelement typu R od 1000 °C do 1767 °C CMC 0,40 °C\nTermoelement typu S od 0 °C do 250 °C CMC 0,47 °C\nTermoelement typu S od 250 °C do 1000 °C CMC 0,36 °C\nTermoelement typu S od 1000 °C do 1400 °C CMC 0,37 °C\nTermoelement typu S od 1400 °C do 1767 °C CMC 0,46 °C\nTermoelement typu T od -250 °C do -150 °C CMC 0,63 °C\nTermoelement typu T od -150 °C do 0 °C CMC 0,24 °C\nTermoelement typu T od 0 °C do 120 °C CMC 0,16 °C\nTermoelement typu T od 120 °C do 400 °C CMC 0,14 °C\nTermoelement typu U od -200 °C do 0 °C CMC 0,57 °C\nTermoelement typu U od 0 °C do 600 °C CMC 0,27 °C\nBezpośrednie generowanie i pomiar kalibratorem równoważnego napięcia stałego z uwzględnieniem wpływu CJC","reference":"TP1, TP21","norm_bases":["TP1","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura / Wzorcowanie części elektrycznej symulatorów temperatury, części elektrycznej przyrządów do pomiaru temperatury za pomocą termoelementów Wzorcowanie – temperatura Bezpośrednie generowanie i pomiar kalibratorem równoważnego napięcia stałego z uwzględnieniem wpływu CJC Termoelement typu B od 600 °C do 800 °C CMC 0,44 °C Termoelement typu B od 800 °C do 1000 °C CMC 0,34 °C Termoelement typu B od 1000 °C do 1550 °C CMC 0,30 °C Termoelement typu B od 1550 °C do 1820 °C CMC 0,33 °C Termoelement typu C od 0 °C do 150 °C CMC 0,30 °C Termoelement typu C od 150 °C do 650 °C CMC 0,26 °C Termoelement typu C od 650 °C do 1000 °C CMC 0,31 °C Termoelement typu C od 1000 °C do 1800 °C CMC 0,50 °C Termoelement typu C od 1800 °C do 2316 °C CMC 0,84 °C Termoelement typu E od -250 °C do -100 °C CMC 0,50 °C Termoelement typu E od -100 °C do -25 °C CMC 0,16 °C Termoelement typu E od -25 °C do 350 °C CMC 0,14 °C Termoelement typu E od 350 °C do 650 °C CMC 0,16 °C Termoelement typu E od 650 °C do 1000 °C CMC 0,21 °C Termoelement typu J od -210 °C do -100 °C CMC 0,27 °C Termoelement typu J od -100 °C do -30 °C CMC 0,16 °C Termoelement typu J od -30 °C do 150 °C CMC 0,14 °C Termoelement typu J od 150 °C do 760 °C CMC 0,17 °C Termoelement typu J od 760 °C do 1200 °C CMC 0,23 °C Termoelement typu K od -200 °C do -100 °C CMC 0,33 °C Termoelement typu K od -100 °C do -25 °C CMC 0,18 °C Termoelement typu K od -25 °C do 120 °C CMC 0,16 °C Termoelement typu K od 120 °C do 1000 °C CMC 0,26 °C Termoelement typu K od 1000 °C do 1372 °C CMC 0,40 °C Termoelement typu L od -200 °C do -100 °C CMC 0,37 °C Termoelement typu L od -100 °C do 800 °C CMC 0,26 °C Termoelement typu L od 800 °C do 900 °C CMC 0,17 °C Termoelement typu N od -200 °C do -100 °C CMC 0,40 °C Termoelement typu N od -100 °C do -25 °C CMC 0,22 °C Termoelement typu N od -25 °C do 120 °C CMC 0,19 °C Termoelement typu N od 120 °C do 410 °C CMC 0,18 °C Termoelement typu N od 410 °C do 1300 °C CMC 0,27 °C Termoelement typu R od 0 °C do 250 °C CMC 0,57 °C Termoelement typu R od 250 °C do 400 °C CMC 0,35 °C Termoelement typu R od 400 °C do 1000 °C CMC 0,33 °C Termoelement typu R od 1000 °C do 1767 °C CMC 0,40 °C Termoelement typu S od 0 °C do 250 °C CMC 0,47 °C Termoelement typu S od 250 °C do 1000 °C CMC 0,36 °C Termoelement typu S od 1000 °C do 1400 °C CMC 0,37 °C Termoelement typu S od 1400 °C do 1767 °C CMC 0,46 °C Termoelement typu T od -250 °C do -150 °C CMC 0,63 °C Termoelement typu T od -150 °C do 0 °C CMC 0,24 °C Termoelement typu T od 0 °C do 120 °C CMC 0,16 °C Termoelement typu T od 120 °C do 400 °C CMC 0,14 °C Termoelement typu U od -200 °C do 0 °C CMC 0,57 °C Termoelement typu U od 0 °C do 600 °C CMC 0,27 °C Teplota / Kalibrace elektrické části simulátorů teploty, elektrické části měřidel teploty pomocí termočlánků Kalibrace – teplota Přímé generování a měření kalibrátorem, ekvivalentního stejnosměrného napětí včetně vlivu CJC Termočlánek typu B 600 °C až 800 °C CMC 0,44 °C Termočlánek typu B 800 °C až 1000 °C CMC 0,34 °C Termočlánek typu B 1000 °C až 1550 °C CMC 0,30 °C Termočlánek typu B 1550 °C až 1820 °C CMC 0,33 °C Termočlánek typu C 0 °C až 150 °C CMC 0,30 °C Termočlánek typu C 150 °C až 650 °C CMC 0,26 °C Termočlánek typu C 650 °C až 1000 °C CMC 0,31 °C Termočlánek typu C 1000 °C až 1800 °C CMC 0,50 °C Termočlánek typu C 1800 °C až 2316 °C CMC 0,84 °C Termočlánek typu E -250 °C až -100 °C CMC 0,50 °C Termočlánek typu E -100 °C až -25 °C CMC 0,16 °C Termočlánek typu E -25 °C až 350 °C CMC 0,14 °C Termočlánek typu E 350 °C až 650 °C CMC 0,16 °C Termočlánek typu E 650 °C až 1000 °C CMC 0,21 °C Termočlánek typu J -210 °C až -100 °C CMC 0,27 °C Termočlánek typu J -100 °C až -30 °C CMC 0,16 °C Termočlánek typu J -30 °C až 150 °C CMC 0,14 °C Termočlánek typu J 150 °C až 760 °C CMC 0,17 °C Termočlánek typu J 760 °C až 1200 °C CMC 0,23 °C Termočlánek typu K -200 °C až -100 °C CMC 0,33 °C Termočlánek typu K -100 °C až -25 °C CMC 0,18 °C Termočlánek typu K -25 °C až 120 °C CMC 0,16 °C Termočlánek typu K 120 °C až 1000 °C CMC 0,26 °C Termočlánek typu K 1000 °C až 1372 °C CMC 0,40 °C Termočlánek typu L -200 °C až -100 °C CMC 0,37 °C Termočlánek typu L -100 °C až 800 °C CMC 0,26 °C Termočlánek typu L 800 °C až 900 °C CMC 0,17 °C Termočlánek typu N -200 °C až -100 °C CMC 0,40 °C Termočlánek typu N -100 °C až -25 °C CMC 0,22 °C Termočlánek typu N -25 °C až 120 °C CMC 0,19 °C Termočlánek typu N 120 °C až 410 °C CMC 0,18 °C Termočlánek typu N 410 °C až 1300 °C CMC 0,27 °C Termočlánek typu R 0 °C až 250 °C CMC 0,57 °C Termočlánek typu R 250 °C až 400 °C CMC 0,35 °C Termočlánek typu R 400 °C až 1000 °C CMC 0,33 °C Termočlánek typu R 1000 °C až 1767 °C CMC 0,40 °C Termočlánek typu S 0 °C až 250 °C CMC 0,47 °C Termočlánek typu S 250 °C až 1000 °C CMC 0,36 °C Termočlánek typu S 1000 °C až 1400 °C CMC 0,37 °C Termočlánek typu S 1400 °C až 1767 °C CMC 0,46 °C Termočlánek typu T -250 °C až -150 °C CMC 0,63 °C Termočlánek typu T -150 °C až 0 °C CMC 0,24 °C Termočlánek typu T 0 °C až 120 °C CMC 0,16 °C Termočlánek typu T 120 °C až 400 °C CMC 0,14 °C Termočlánek typu U -200 °C až 0 °C CMC 0,57 °C Termočlánek typu U 0 °C až 600 °C CMC 0,27 °C TP1, TP21 Temperatura / Wzorcowanie czesci elektrycznej symulatorow temperatury, czesci elektrycznej przyrzadow do pomiaru temperatury za pomoca termoelementow Wzorcowanie – temperatura Bezposrednie generowanie i pomiar kalibratorem rownowaznego napiecia stalego z uwzglednieniem wplywu CJC Termoelement typu B od 600 °C do 800 °C CMC 0,44 °C Termoelement typu B od 800 °C do 1000 °C CMC 0,34 °C Termoelement typu B od 1000 °C do 1550 °C CMC 0,30 °C Termoelement typu B od 1550 °C do 1820 °C CMC 0,33 °C Termoelement typu C od 0 °C do 150 °C CMC 0,30 °C Termoelement typu C od 150 °C do 650 °C CMC 0,26 °C Termoelement typu C od 650 °C do 1000 °C CMC 0,31 °C Termoelement typu C od 1000 °C do 1800 °C CMC 0,50 °C Termoelement typu C od 1800 °C do 2316 °C CMC 0,84 °C Termoelement typu E od -250 °C do -100 °C CMC 0,50 °C Termoelement typu E od -100 °C do -25 °C CMC 0,16 °C Termoelement typu E od -25 °C do 350 °C CMC 0,14 °C Termoelement typu E od 350 °C do 650 °C CMC 0,16 °C Termoelement typu E od 650 °C do 1000 °C CMC 0,21 °C Termoelement typu J od -210 °C do -100 °C CMC 0,27 °C Termoelement typu J od -100 °C do -30 °C CMC 0,16 °C Termoelement typu J od -30 °C do 150 °C CMC 0,14 °C Termoelement typu J od 150 °C do 760 °C CMC 0,17 °C Termoelement typu J od 760 °C do 1200 °C CMC 0,23 °C Termoelement typu K od -200 °C do -100 °C CMC 0,33 °C Termoelement typu K od -100 °C do -25 °C CMC 0,18 °C Termoelement typu K od -25 °C do 120 °C CMC 0,16 °C Termoelement typu K od 120 °C do 1000 °C CMC 0,26 °C Termoelement typu K od 1000 °C do 1372 °C CMC 0,40 °C Termoelement typu L od -200 °C do -100 °C CMC 0,37 °C Termoelement typu L od -100 °C do 800 °C CMC 0,26 °C Termoelement typu L od 800 °C do 900 °C CMC 0,17 °C Termoelement typu N od -200 °C do -100 °C CMC 0,40 °C Termoelement typu N od -100 °C do -25 °C CMC 0,22 °C Termoelement typu N od -25 °C do 120 °C CMC 0,19 °C Termoelement typu N od 120 °C do 410 °C CMC 0,18 °C Termoelement typu N od 410 °C do 1300 °C CMC 0,27 °C Termoelement typu R od 0 °C do 250 °C CMC 0,57 °C Termoelement typu R od 250 °C do 400 °C CMC 0,35 °C Termoelement typu R od 400 °C do 1000 °C CMC 0,33 °C Termoelement typu R od 1000 °C do 1767 °C CMC 0,40 °C Termoelement typu S od 0 °C do 250 °C CMC 0,47 °C Termoelement typu S od 250 °C do 1000 °C CMC 0,36 °C Termoelement typu S od 1000 °C do 1400 °C CMC 0,37 °C Termoelement typu S od 1400 °C do 1767 °C CMC 0,46 °C Termoelement typu T od -250 °C do -150 °C CMC 0,63 °C Termoelement typu T od -150 °C do 0 °C CMC 0,24 °C Termoelement typu T od 0 °C do 120 °C CMC 0,16 °C Termoelement typu T od 120 °C do 400 °C CMC 0,14 °C Termoelement typu U od -200 °C do 0 °C CMC 0,57 °C Termoelement typu U od 0 °C do 600 °C CMC 0,27 °C Teplota / Kalibrace elektricke casti simulatoru teploty, elektricke casti meridel teploty pomoci termoclanku Kalibrace – teplota Prime generovani a mereni kalibratorem, ekvivalentniho stejnosmerneho napeti vcetne vlivu CJC Termoclanek typu B 600 °C az 800 °C CMC 0,44 °C Termoclanek typu B 800 °C az 1000 °C CMC 0,34 °C Termoclanek typu B 1000 °C az 1550 °C CMC 0,30 °C Termoclanek typu B 1550 °C az 1820 °C CMC 0,33 °C Termoclanek typu C 0 °C az 150 °C CMC 0,30 °C Termoclanek typu C 150 °C az 650 °C CMC 0,26 °C Termoclanek typu C 650 °C az 1000 °C CMC 0,31 °C Termoclanek typu C 1000 °C az 1800 °C CMC 0,50 °C Termoclanek typu C 1800 °C az 2316 °C CMC 0,84 °C Termoclanek typu E -250 °C az -100 °C CMC 0,50 °C Termoclanek typu E -100 °C az -25 °C CMC 0,16 °C Termoclanek typu E -25 °C az 350 °C CMC 0,14 °C Termoclanek typu E 350 °C az 650 °C CMC 0,16 °C Termoclanek typu E 650 °C az 1000 °C CMC 0,21 °C Termoclanek typu J -210 °C az -100 °C CMC 0,27 °C Termoclanek typu J -100 °C az -30 °C CMC 0,16 °C Termoclanek typu J -30 °C az 150 °C CMC 0,14 °C Termoclanek typu J 150 °C az 760 °C CMC 0,17 °C Termoclanek typu J 760 °C az 1200 °C CMC 0,23 °C Termoclanek typu K -200 °C az -100 °C CMC 0,33 °C Termoclanek typu K -100 °C az -25 °C CMC 0,18 °C Termoclanek typu K -25 °C az 120 °C CMC 0,16 °C Termoclanek typu K 120 °C az 1000 °C CMC 0,26 °C Termoclanek typu K 1000 °C az 1372 °C CMC 0,40 °C Termoclanek typu L -200 °C az -100 °C CMC 0,37 °C Termoclanek typu L -100 °C az 800 °C CMC 0,26 °C Termoclanek typu L 800 °C az 900 °C CMC 0,17 °C Termoclanek typu N -200 °C az -100 °C CMC 0,40 °C Termoclanek typu N -100 °C az -25 °C CMC 0,22 °C Termoclanek typu N -25 °C az 120 °C CMC 0,19 °C Termoclanek typu N 120 °C az 410 °C CMC 0,18 °C Termoclanek typu N 410 °C az 1300 °C CMC 0,27 °C Termoclanek typu R 0 °C az 250 °C CMC 0,57 °C Termoclanek typu R 250 °C az 400 °C CMC 0,35 °C Termoclanek typu R 400 °C az 1000 °C CMC 0,33 °C Termoclanek typu R 1000 °C az 1767 °C CMC 0,40 °C Termoclanek typu S 0 °C az 250 °C CMC 0,47 °C Termoclanek typu S 250 °C az 1000 °C CMC 0,36 °C Termoclanek typu S 1000 °C az 1400 °C CMC 0,37 °C Termoclanek typu S 1400 °C az 1767 °C CMC 0,46 °C Termoclanek typu T -250 °C az -150 °C CMC 0,63 °C Termoclanek typu T -150 °C az 0 °C CMC 0,24 °C Termoclanek typu T 0 °C az 120 °C CMC 0,16 °C Termoclanek typu T 120 °C az 400 °C CMC 0,14 °C Termoclanek typu U -200 °C az 0 °C CMC 0,57 °C Termoclanek typu U 0 °C az 600 °C CMC 0,27 °C TP1, TP21","search_en":"Temperature / Calibration of electrical part of temperature simulators, electrical parts of temperature gauges using thermocouples Calibration – temperature Direct calibrator generation and measurement, of equivalent DC voltage including the effect of CJC Type B thermocouple 600 °C to 800 °C CMC 0,44 °C Type B thermocouple 800 °C to 1000 °C CMC 0,34 °C Type B thermocouple 1000 °C to 1550 °C CMC 0,30 °C Type B thermocouple 1550 °C to 1820 °C CMC 0,33 °C Type C thermocouple 0 °C to 150 °C CMC 0,30 °C Type C thermocouple 150 °C to 650 °C CMC 0,26 °C Type C thermocouple 650 °C to 1000 °C CMC 0,31 °C Type C thermocouple 1000 °C to 1800 °C CMC 0,50 °C Type C thermocouple 1800 °C to 2316 °C CMC 0,84 °C Type E thermocouple -250 °C to -100 °C CMC 0,50 °C Type E thermocouple -100 °C to -25 °C CMC 0,16 °C Type E thermocouple -25 °C to 350 °C CMC 0,14 °C Type E thermocouple 350 °C to 650 °C CMC 0,16 °C Type E thermocouple 650 °C to 1000 °C CMC 0,21 °C Type J thermocouple -210 °C to -100 °C CMC 0,27 °C Type J thermocouple -100 °C to -30 °C CMC 0,16 °C Type J thermocouple -30 °C to 150 °C CMC 0,14 °C Type J thermocouple 150 °C to 760 °C CMC 0,17 °C Type J thermocouple 760 °C to 1200 °C CMC 0,23 °C Type K thermocouple -200 °C to -100 °C CMC 0,33 °C Type K thermocouple -100 °C to -25 °C CMC 0,18 °C Type K thermocouple -25 °C to 120 °C CMC 0,16 °C Type K thermocouple 120 °C to 1000 °C CMC 0,26 °C Type K thermocouple 1000 °C to 1372 °C CMC 0,40 °C Type L thermocouple -200 °C to -100 °C CMC 0,37 °C Type L thermocouple -100 °C to 800 °C CMC 0,26 °C Type L thermocouple 800 °C to 900 °C CMC 0,17 °C Type N thermocouple -200 °C to -100 °C CMC 0,40 °C Type N thermocouple -100 °C to -25 °C CMC 0,22 °C Type N thermocouple -25 °C to 120 °C CMC 0,19 °C Type N thermocouple 120 °C to 410 °C CMC 0,18 °C Type N thermocouple 410 °C to 1300 °C CMC 0,27 °C Type R thermocouple 0 °C to 250 °C CMC 0,57 °C Type R thermocouple 250 °C to 400 °C CMC 0,35 °C Type R thermocouple 400 °C to 1000 °C CMC 0,33 °C Type R thermocouple 1000 °C to 1767 °C CMC 0,40 °C Type S thermocouple 0 °C to 250 °C CMC 0,47 °C Type S thermocouple 250 °C to 1000 °C CMC 0,36 °C Type S thermocouple 1000 °C to 1400 °C CMC 0,37 °C Type S thermocouple 1400 °C to 1767 °C CMC 0,46 °C Type T thermocouple -250 °C to -150 °C CMC 0,63 °C Type T thermocouple -150 °C to 0 °C CMC 0,24 °C Type T thermocouple 0 °C to 120 °C CMC 0,16 °C Type T thermocouple 120 °C to 400 °C CMC 0,14 °C Type U thermocouple -200 °C to 0 °C CMC 0,57 °C Type U thermocouple 0 °C to 600 °C CMC 0,27 °C TP1, TP21","search_zh":"温度 / 温度模拟器电气部分、使用热电偶的温度测量仪器电气部分的校准 校准 – 温度 用校准器直接产生和测量等效直流电压（含 CJC 影响） B 型热电偶 600 °C 至 800 °C CMC 0,44 °C B 型热电偶 800 °C 至 1000 °C CMC 0,34 °C B 型热电偶 1000 °C 至 1550 °C CMC 0,30 °C B 型热电偶 1550 °C 至 1820 °C CMC 0,33 °C C 型热电偶 0 °C 至 150 °C CMC 0,30 °C C 型热电偶 150 °C 至 650 °C CMC 0,26 °C C 型热电偶 650 °C 至 1000 °C CMC 0,31 °C C 型热电偶 1000 °C 至 1800 °C CMC 0,50 °C C 型热电偶 1800 °C 至 2316 °C CMC 0,84 °C E 型热电偶 -250 °C 至 -100 °C CMC 0,50 °C E 型热电偶 -100 °C 至 -25 °C CMC 0,16 °C E 型热电偶 -25 °C 至 350 °C CMC 0,14 °C E 型热电偶 350 °C 至 650 °C CMC 0,16 °C E 型热电偶 650 °C 至 1000 °C CMC 0,21 °C J 型热电偶 -210 °C 至 -100 °C CMC 0,27 °C J 型热电偶 -100 °C 至 -30 °C CMC 0,16 °C J 型热电偶 -30 °C 至 150 °C CMC 0,14 °C J 型热电偶 150 °C 至 760 °C CMC 0,17 °C J 型热电偶 760 °C 至 1200 °C CMC 0,23 °C K 型热电偶 -200 °C 至 -100 °C CMC 0,33 °C K 型热电偶 -100 °C 至 -25 °C CMC 0,18 °C K 型热电偶 -25 °C 至 120 °C CMC 0,16 °C K 型热电偶 120 °C 至 1000 °C CMC 0,26 °C K 型热电偶 1000 °C 至 1372 °C CMC 0,40 °C L 型热电偶 -200 °C 至 -100 °C CMC 0,37 °C L 型热电偶 -100 °C 至 800 °C CMC 0,26 °C L 型热电偶 800 °C 至 900 °C CMC 0,17 °C N 型热电偶 -200 °C 至 -100 °C CMC 0,40 °C N 型热电偶 -100 °C 至 -25 °C CMC 0,22 °C N 型热电偶 -25 °C 至 120 °C CMC 0,19 °C N 型热电偶 120 °C 至 410 °C CMC 0,18 °C N 型热电偶 410 °C 至 1300 °C CMC 0,27 °C R 型热电偶 0 °C 至 250 °C CMC 0,57 °C R 型热电偶 250 °C 至 400 °C CMC 0,35 °C R 型热电偶 400 °C 至 1000 °C CMC 0,33 °C R 型热电偶 1000 °C 至 1767 °C CMC 0,40 °C S 型热电偶 0 °C 至 250 °C CMC 0,47 °C S 型热电偶 250 °C 至 1000 °C CMC 0,36 °C S 型热电偶 1000 °C 至 1400 °C CMC 0,37 °C S 型热电偶 1400 °C 至 1767 °C CMC 0,46 °C T 型热电偶 -250 °C 至 -150 °C CMC 0,63 °C T 型热电偶 -150 °C 至 0 °C CMC 0,24 °C T 型热电偶 0 °C 至 120 °C CMC 0,16 °C T 型热电偶 120 °C 至 400 °C CMC 0,14 °C U 型热电偶 -200 °C 至 0 °C CMC 0,57 °C U 型热电偶 0 °C 至 600 °C CMC 0,27 °C TP1, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f7ccbab16b80680385e9129","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"6","test_object":"Temperatura / Wzorcowanie części elektrycznej przyrządów do pomiaru temperatury za pomocą czujników RTD","test_object_en":"Temperature / Calibration of electric part of thermometers using RTD sensors","test_object_zh":"温度 / 使用 RTD 传感器的温度测量仪器电气部分校准","test_object_cs":"Teplota / Kalibrace elektrické části měřidel teploty pomocí RTD snímačů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"RTD typu Pt 385, 100 Ω","range":"od -200 °C do 0 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"od 0 °C do 100 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"od 100 °C do 300 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"od 300 °C do 400 °C","cmc":"0,10 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"od 400 °C do 630 °C","cmc":"0,12 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"od 630 °C do 800 °C","cmc":"0,23 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"od -200 °C do 0 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"od 0 °C do 100 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"od 100 °C do 300 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"od 300 °C do 400 °C","cmc":"0,10 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"od 400 °C do 630 °C","cmc":"0,12 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od -200 °C do -190 °C","cmc":"0,25 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od -190 °C do -80 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od -80 °C do 0 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od 0 °C do 100 °C","cmc":"0,06 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od 100 °C do 260 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od 260 °C do 300 °C","cmc":"0,08 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od 300 °C do 400 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od 400 °C do 600 °C","cmc":"0,10 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"od 600 °C do 630 °C","cmc":"0,23 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"od -200 °C do 100 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"od 100 °C do 260 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"od 260 °C do 300 °C","cmc":"0,12 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"od 300 °C do 400 °C","cmc":"0,13 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"od 400 °C do 600 °C","cmc":"0,14 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"od 600 °C do 630 °C","cmc":"0,16 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"od -200 °C do -80 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"od -80 °C do 100 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"od 100 °C do 260 °C","cmc":"0,06 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"od 260 °C do 400 °C","cmc":"0,08 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"od 400 °C do 600 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"od 600 °C do 630 °C","cmc":"0,11 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"od -200 °C do 0 °C","cmc":"0,03 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"od 0 °C do 100 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"od 100 °C do 260 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"od 260 °C do 300 °C","cmc":"0,06 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"od 300 °C do 600 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"od 600 °C do 630 °C","cmc":"0,23 °C"},{"name":"RTD typu PtNi 385 120 Ω","range":"od -80 °C do 100 °C","cmc":"0,08 °C"},{"name":"RTD typu PtNi 385 120 Ω","range":"od 100 °C do 260 °C","cmc":"0,14 °C"},{"name":"Cu 427, 10 Ω","range":"od -100 °C do 260 °C","cmc":"0,30 °C"}],"parameters_en":[{"name":"RTD type Pt 385, 100 Ω","range":"-200 °C to 0 °C","cmc":"0,05 °C"},{"name":"RTD type Pt 385, 100 Ω","range":"0 °C to 100 °C","cmc":"0,07 °C"},{"name":"RTD type Pt 385, 100 Ω","range":"100 °C to 300 °C","cmc":"0,09 °C"},{"name":"RTD type Pt 385, 100 Ω","range":"300 °C to 400 °C","cmc":"0,10 °C"},{"name":"RTD type Pt 385, 100 Ω","range":"400 °C to 630 °C","cmc":"0,12 °C"},{"name":"RTD type Pt 385, 100 Ω","range":"630 °C to 800 °C","cmc":"0,23 °C"},{"name":"RTD type Pt 3926, 100 Ω","range":"-200 °C to 0 °C","cmc":"0,05 °C"},{"name":"RTD type Pt 3926, 100 Ω","range":"0 °C to 100 °C","cmc":"0,07 °C"},{"name":"RTD type Pt 3926, 100 Ω","range":"100 °C to 300 °C","cmc":"0,09 °C"},{"name":"RTD type Pt 3926, 100 Ω","range":"300 °C to 400 °C","cmc":"0,10 °C"},{"name":"RTD type Pt 3926, 100 Ω","range":"400 °C to 630 °C","cmc":"0,12 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"-200 °C to -190 °C","cmc":"0,25 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"-190 °C to -80 °C","cmc":"0,04 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"-80 °C to 0 °C","cmc":"0,05 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"0 °C to 100 °C","cmc":"0,06 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"100 °C to 260 °C","cmc":"0,07 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"260 °C to 300 °C","cmc":"0,08 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"300 °C to 400 °C","cmc":"0,09 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"400 °C to 600 °C","cmc":"0,10 °C"},{"name":"RTD type Pt 3916, 100 Ω","range":"600 °C to 630 °C","cmc":"0,23 °C"},{"name":"RTD type Pt 385, 200 Ω","range":"-200 °C to 100 °C","cmc":"0,04 °C"},{"name":"RTD type Pt 385, 200 Ω","range":"100 °C to 260 °C","cmc":"0,05 °C"},{"name":"RTD type Pt 385, 200 Ω","range":"260 °C to 300 °C","cmc":"0,12 °C"},{"name":"RTD type Pt 385, 200 Ω","range":"300 °C to 400 °C","cmc":"0,13 °C"},{"name":"RTD type Pt 385, 200 Ω","range":"400 °C to 600 °C","cmc":"0,14 °C"},{"name":"RTD type Pt 385, 200 Ω","range":"600 °C to 630 °C","cmc":"0,16 °C"},{"name":"RTD type Pt 385, 500 Ω","range":"-200 °C to -80 °C","cmc":"0,04 °C"},{"name":"RTD type Pt 385, 500 Ω","range":"-80 °C to 100 °C","cmc":"0,05 °C"},{"name":"RTD type Pt 385, 500 Ω","range":"100 °C to 260 °C","cmc":"0,06 °C"},{"name":"RTD type Pt 385, 500 Ω","range":"260 °C to 400 °C","cmc":"0,08 °C"},{"name":"RTD type Pt 385, 500 Ω","range":"400 °C to 600 °C","cmc":"0,09 °C"},{"name":"RTD type Pt 385, 500 Ω","range":"600 °C to 630 °C","cmc":"0,11 °C"},{"name":"RTD type Pt 385, 1000 Ω","range":"-200 °C to 0 °C","cmc":"0,03 °C"},{"name":"RTD type Pt 385, 1000 Ω","range":"0 °C to 100 °C","cmc":"0,04 °C"},{"name":"RTD type Pt 385, 1000 Ω","range":"100 °C to 260 °C","cmc":"0,05 °C"},{"name":"RTD type Pt 385, 1000 Ω","range":"260 °C to 300 °C","cmc":"0,06 °C"},{"name":"RTD type Pt 385, 1000 Ω","range":"300 °C to 600 °C","cmc":"0,07 °C"},{"name":"RTD type Pt 385, 1000 Ω","range":"600 °C to 630 °C","cmc":"0,23 °C"},{"name":"RTD type PtNi 385 120 Ω","range":"-80 °C to 100 °C","cmc":"0,08 °C"},{"name":"RTD type PtNi 385 120 Ω","range":"100 °C to 260 °C","cmc":"0,14 °C"},{"name":"Cu 427, 10 Ω","range":"-100 °C to 260 °C","cmc":"0,30 °C"}],"parameters_zh":[{"name":"Pt 385 型 RTD，100 Ω","range":"-200 °C 至 0 °C","cmc":"0,05 °C"},{"name":"Pt 385 型 RTD，100 Ω","range":"0 °C 至 100 °C","cmc":"0,07 °C"},{"name":"Pt 385 型 RTD，100 Ω","range":"100 °C 至 300 °C","cmc":"0,09 °C"},{"name":"Pt 385 型 RTD，100 Ω","range":"300 °C 至 400 °C","cmc":"0,10 °C"},{"name":"Pt 385 型 RTD，100 Ω","range":"400 °C 至 630 °C","cmc":"0,12 °C"},{"name":"Pt 385 型 RTD，100 Ω","range":"630 °C 至 800 °C","cmc":"0,23 °C"},{"name":"Pt 3926 型 RTD，100 Ω","range":"-200 °C 至 0 °C","cmc":"0,05 °C"},{"name":"Pt 3926 型 RTD，100 Ω","range":"0 °C 至 100 °C","cmc":"0,07 °C"},{"name":"Pt 3926 型 RTD，100 Ω","range":"100 °C 至 300 °C","cmc":"0,09 °C"},{"name":"Pt 3926 型 RTD，100 Ω","range":"300 °C 至 400 °C","cmc":"0,10 °C"},{"name":"Pt 3926 型 RTD，100 Ω","range":"400 °C 至 630 °C","cmc":"0,12 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"-200 °C 至 -190 °C","cmc":"0,25 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"-190 °C 至 -80 °C","cmc":"0,04 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"-80 °C 至 0 °C","cmc":"0,05 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"0 °C 至 100 °C","cmc":"0,06 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"100 °C 至 260 °C","cmc":"0,07 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"260 °C 至 300 °C","cmc":"0,08 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"300 °C 至 400 °C","cmc":"0,09 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"400 °C 至 600 °C","cmc":"0,10 °C"},{"name":"Pt 3916 型 RTD，100 Ω","range":"600 °C 至 630 °C","cmc":"0,23 °C"},{"name":"Pt 385 型 RTD，200 Ω","range":"-200 °C 至 100 °C","cmc":"0,04 °C"},{"name":"Pt 385 型 RTD，200 Ω","range":"100 °C 至 260 °C","cmc":"0,05 °C"},{"name":"Pt 385 型 RTD，200 Ω","range":"260 °C 至 300 °C","cmc":"0,12 °C"},{"name":"Pt 385 型 RTD，200 Ω","range":"300 °C 至 400 °C","cmc":"0,13 °C"},{"name":"Pt 385 型 RTD，200 Ω","range":"400 °C 至 600 °C","cmc":"0,14 °C"},{"name":"Pt 385 型 RTD，200 Ω","range":"600 °C 至 630 °C","cmc":"0,16 °C"},{"name":"Pt 385 型 RTD，500 Ω","range":"-200 °C 至 -80 °C","cmc":"0,04 °C"},{"name":"Pt 385 型 RTD，500 Ω","range":"-80 °C 至 100 °C","cmc":"0,05 °C"},{"name":"Pt 385 型 RTD，500 Ω","range":"100 °C 至 260 °C","cmc":"0,06 °C"},{"name":"Pt 385 型 RTD，500 Ω","range":"260 °C 至 400 °C","cmc":"0,08 °C"},{"name":"Pt 385 型 RTD，500 Ω","range":"400 °C 至 600 °C","cmc":"0,09 °C"},{"name":"Pt 385 型 RTD，500 Ω","range":"600 °C 至 630 °C","cmc":"0,11 °C"},{"name":"Pt 385 型 RTD，1000 Ω","range":"-200 °C 至 0 °C","cmc":"0,03 °C"},{"name":"Pt 385 型 RTD，1000 Ω","range":"0 °C 至 100 °C","cmc":"0,04 °C"},{"name":"Pt 385 型 RTD，1000 Ω","range":"100 °C 至 260 °C","cmc":"0,05 °C"},{"name":"Pt 385 型 RTD，1000 Ω","range":"260 °C 至 300 °C","cmc":"0,06 °C"},{"name":"Pt 385 型 RTD，1000 Ω","range":"300 °C 至 600 °C","cmc":"0,07 °C"},{"name":"Pt 385 型 RTD，1000 Ω","range":"600 °C 至 630 °C","cmc":"0,23 °C"},{"name":"PtNi 385 型 RTD 120 Ω","range":"-80 °C 至 100 °C","cmc":"0,08 °C"},{"name":"PtNi 385 型 RTD 120 Ω","range":"100 °C 至 260 °C","cmc":"0,14 °C"},{"name":"Cu 427, 10 Ω","range":"-100 °C 至 260 °C","cmc":"0,30 °C"}],"parameters_cs":[{"name":"RTD typu Pt 385, 100 Ω","range":"-200 °C až 0 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"0 °C až 100 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"100 °C až 300 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"300 °C až 400 °C","cmc":"0,10 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"400 °C až 630 °C","cmc":"0,12 °C"},{"name":"RTD typu Pt 385, 100 Ω","range":"630 °C až 800 °C","cmc":"0,23 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"-200 °C až 0 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"0 °C až 100 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"100 °C až 300 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"300 °C až 400 °C","cmc":"0,10 °C"},{"name":"RTD typu Pt 3926, 100 Ω","range":"400 °C až 630 °C","cmc":"0,12 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"-200 °C až -190 °C","cmc":"0,25 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"-190 °C až -80 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"-80 °C až 0 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"0 °C až 100 °C","cmc":"0,06 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"100 °C až 260 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"260 °C až 300 °C","cmc":"0,08 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"300 °C až 400 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"400 °C až 600 °C","cmc":"0,10 °C"},{"name":"RTD typu Pt 3916, 100 Ω","range":"600 °C až 630 °C","cmc":"0,23 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"-200 °C až 100 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"100 °C až 260 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"260 °C až 300 °C","cmc":"0,12 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"300 °C až 400 °C","cmc":"0,13 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"400 °C až 600 °C","cmc":"0,14 °C"},{"name":"RTD typu Pt 385, 200 Ω","range":"600 °C až 630 °C","cmc":"0,16 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"-200 °C až -80 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"-80 °C až 100 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"100 °C až 260 °C","cmc":"0,06 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"260 °C až 400 °C","cmc":"0,08 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"400 °C až 600 °C","cmc":"0,09 °C"},{"name":"RTD typu Pt 385, 500 Ω","range":"600 °C až 630 °C","cmc":"0,11 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"-200 °C až 0 °C","cmc":"0,03 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"0 °C až 100 °C","cmc":"0,04 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"100 °C až 260 °C","cmc":"0,05 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"260 °C až 300 °C","cmc":"0,06 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"300 °C až 600 °C","cmc":"0,07 °C"},{"name":"RTD typu Pt 385, 1000 Ω","range":"600 °C až 630 °C","cmc":"0,23 °C"},{"name":"RTD typu PtNi 385 120 Ω","range":"-80 °C až 100 °C","cmc":"0,08 °C"},{"name":"RTD typu PtNi 385 120 Ω","range":"100 °C až 260 °C","cmc":"0,14 °C"},{"name":"Cu 427, 10 Ω","range":"-100 °C až 260 °C","cmc":"0,30 °C"}],"technique":"Bezpośrednie generowanie kalibratorem, generowanie równoważnej rezystancji","technique_en":"Direct generation by a calibrator, equivalent resistance generation","technique_zh":"用校准器直接产生，产生等效电阻","technique_cs":"Přímé generování kalibrátorem, generování ekvivalentního odporu","techniques":["Bezpośrednie generowanie kalibratorem, generowanie równoważnej rezystancji"],"techniques_en":["Direct generation by a calibrator, equivalent resistance generation"],"techniques_zh":["用校准器直接产生，产生等效电阻"],"techniques_cs":["Přímé generování kalibrátorem, generování ekvivalentního odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nRTD typu Pt 385, 100 Ω od -200 °C do 0 °C CMC 0,05 °C\nRTD typu Pt 385, 100 Ω od 0 °C do 100 °C CMC 0,07 °C\nRTD typu Pt 385, 100 Ω od 100 °C do 300 °C CMC 0,09 °C\nRTD typu Pt 385, 100 Ω od 300 °C do 400 °C CMC 0,10 °C\nRTD typu Pt 385, 100 Ω od 400 °C do 630 °C CMC 0,12 °C\nRTD typu Pt 385, 100 Ω od 630 °C do 800 °C CMC 0,23 °C\nRTD typu Pt 3926, 100 Ω od -200 °C do 0 °C CMC 0,05 °C\nRTD typu Pt 3926, 100 Ω od 0 °C do 100 °C CMC 0,07 °C\nRTD typu Pt 3926, 100 Ω od 100 °C do 300 °C CMC 0,09 °C\nRTD typu Pt 3926, 100 Ω od 300 °C do 400 °C CMC 0,10 °C\nRTD typu Pt 3926, 100 Ω od 400 °C do 630 °C CMC 0,12 °C\nRTD typu Pt 3916, 100 Ω od -200 °C do -190 °C CMC 0,25 °C\nRTD typu Pt 3916, 100 Ω od -190 °C do -80 °C CMC 0,04 °C\nRTD typu Pt 3916, 100 Ω od -80 °C do 0 °C CMC 0,05 °C\nRTD typu Pt 3916, 100 Ω od 0 °C do 100 °C CMC 0,06 °C\nRTD typu Pt 3916, 100 Ω od 100 °C do 260 °C CMC 0,07 °C\nRTD typu Pt 3916, 100 Ω od 260 °C do 300 °C CMC 0,08 °C\nRTD typu Pt 3916, 100 Ω od 300 °C do 400 °C CMC 0,09 °C\nRTD typu Pt 3916, 100 Ω od 400 °C do 600 °C CMC 0,10 °C\nRTD typu Pt 3916, 100 Ω od 600 °C do 630 °C CMC 0,23 °C\nRTD typu Pt 385, 200 Ω od -200 °C do 100 °C CMC 0,04 °C\nRTD typu Pt 385, 200 Ω od 100 °C do 260 °C CMC 0,05 °C\nRTD typu Pt 385, 200 Ω od 260 °C do 300 °C CMC 0,12 °C\nRTD typu Pt 385, 200 Ω od 300 °C do 400 °C CMC 0,13 °C\nRTD typu Pt 385, 200 Ω od 400 °C do 600 °C CMC 0,14 °C\nRTD typu Pt 385, 200 Ω od 600 °C do 630 °C CMC 0,16 °C\nRTD typu Pt 385, 500 Ω od -200 °C do -80 °C CMC 0,04 °C\nRTD typu Pt 385, 500 Ω od -80 °C do 100 °C CMC 0,05 °C\nRTD typu Pt 385, 500 Ω od 100 °C do 260 °C CMC 0,06 °C\nRTD typu Pt 385, 500 Ω od 260 °C do 400 °C CMC 0,08 °C\nRTD typu Pt 385, 500 Ω od 400 °C do 600 °C CMC 0,09 °C\nRTD typu Pt 385, 500 Ω od 600 °C do 630 °C CMC 0,11 °C\nRTD typu Pt 385, 1000 Ω od -200 °C do 0 °C CMC 0,03 °C\nRTD typu Pt 385, 1000 Ω od 0 °C do 100 °C CMC 0,04 °C\nRTD typu Pt 385, 1000 Ω od 100 °C do 260 °C CMC 0,05 °C\nRTD typu Pt 385, 1000 Ω od 260 °C do 300 °C CMC 0,06 °C\nRTD typu Pt 385, 1000 Ω od 300 °C do 600 °C CMC 0,07 °C\nRTD typu Pt 385, 1000 Ω od 600 °C do 630 °C CMC 0,23 °C\nRTD typu PtNi 385 120 Ω od -80 °C do 100 °C CMC 0,08 °C\nRTD typu PtNi 385 120 Ω od 100 °C do 260 °C CMC 0,14 °C\nCu 427, 10 Ω od -100 °C do 260 °C CMC 0,30 °C\nBezpośrednie generowanie kalibratorem, generowanie równoważnej rezystancji","reference":"TP5, TP21","norm_bases":["TP5","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura / Wzorcowanie części elektrycznej przyrządów do pomiaru temperatury za pomocą czujników RTD Wzorcowanie – temperatura Bezpośrednie generowanie kalibratorem, generowanie równoważnej rezystancji RTD typu Pt 385, 100 Ω od -200 °C do 0 °C CMC 0,05 °C RTD typu Pt 385, 100 Ω od 0 °C do 100 °C CMC 0,07 °C RTD typu Pt 385, 100 Ω od 100 °C do 300 °C CMC 0,09 °C RTD typu Pt 385, 100 Ω od 300 °C do 400 °C CMC 0,10 °C RTD typu Pt 385, 100 Ω od 400 °C do 630 °C CMC 0,12 °C RTD typu Pt 385, 100 Ω od 630 °C do 800 °C CMC 0,23 °C RTD typu Pt 3926, 100 Ω od -200 °C do 0 °C CMC 0,05 °C RTD typu Pt 3926, 100 Ω od 0 °C do 100 °C CMC 0,07 °C RTD typu Pt 3926, 100 Ω od 100 °C do 300 °C CMC 0,09 °C RTD typu Pt 3926, 100 Ω od 300 °C do 400 °C CMC 0,10 °C RTD typu Pt 3926, 100 Ω od 400 °C do 630 °C CMC 0,12 °C RTD typu Pt 3916, 100 Ω od -200 °C do -190 °C CMC 0,25 °C RTD typu Pt 3916, 100 Ω od -190 °C do -80 °C CMC 0,04 °C RTD typu Pt 3916, 100 Ω od -80 °C do 0 °C CMC 0,05 °C RTD typu Pt 3916, 100 Ω od 0 °C do 100 °C CMC 0,06 °C RTD typu Pt 3916, 100 Ω od 100 °C do 260 °C CMC 0,07 °C RTD typu Pt 3916, 100 Ω od 260 °C do 300 °C CMC 0,08 °C RTD typu Pt 3916, 100 Ω od 300 °C do 400 °C CMC 0,09 °C RTD typu Pt 3916, 100 Ω od 400 °C do 600 °C CMC 0,10 °C RTD typu Pt 3916, 100 Ω od 600 °C do 630 °C CMC 0,23 °C RTD typu Pt 385, 200 Ω od -200 °C do 100 °C CMC 0,04 °C RTD typu Pt 385, 200 Ω od 100 °C do 260 °C CMC 0,05 °C RTD typu Pt 385, 200 Ω od 260 °C do 300 °C CMC 0,12 °C RTD typu Pt 385, 200 Ω od 300 °C do 400 °C CMC 0,13 °C RTD typu Pt 385, 200 Ω od 400 °C do 600 °C CMC 0,14 °C RTD typu Pt 385, 200 Ω od 600 °C do 630 °C CMC 0,16 °C RTD typu Pt 385, 500 Ω od -200 °C do -80 °C CMC 0,04 °C RTD typu Pt 385, 500 Ω od -80 °C do 100 °C CMC 0,05 °C RTD typu Pt 385, 500 Ω od 100 °C do 260 °C CMC 0,06 °C RTD typu Pt 385, 500 Ω od 260 °C do 400 °C CMC 0,08 °C RTD typu Pt 385, 500 Ω od 400 °C do 600 °C CMC 0,09 °C RTD typu Pt 385, 500 Ω od 600 °C do 630 °C CMC 0,11 °C RTD typu Pt 385, 1000 Ω od -200 °C do 0 °C CMC 0,03 °C RTD typu Pt 385, 1000 Ω od 0 °C do 100 °C CMC 0,04 °C RTD typu Pt 385, 1000 Ω od 100 °C do 260 °C CMC 0,05 °C RTD typu Pt 385, 1000 Ω od 260 °C do 300 °C CMC 0,06 °C RTD typu Pt 385, 1000 Ω od 300 °C do 600 °C CMC 0,07 °C RTD typu Pt 385, 1000 Ω od 600 °C do 630 °C CMC 0,23 °C RTD typu PtNi 385 120 Ω od -80 °C do 100 °C CMC 0,08 °C RTD typu PtNi 385 120 Ω od 100 °C do 260 °C CMC 0,14 °C Cu 427, 10 Ω od -100 °C do 260 °C CMC 0,30 °C Teplota / Kalibrace elektrické části měřidel teploty pomocí RTD snímačů Kalibrace – teplota Přímé generování kalibrátorem, generování ekvivalentního odporu RTD typu Pt 385, 100 Ω -200 °C až 0 °C CMC 0,05 °C RTD typu Pt 385, 100 Ω 0 °C až 100 °C CMC 0,07 °C RTD typu Pt 385, 100 Ω 100 °C až 300 °C CMC 0,09 °C RTD typu Pt 385, 100 Ω 300 °C až 400 °C CMC 0,10 °C RTD typu Pt 385, 100 Ω 400 °C až 630 °C CMC 0,12 °C RTD typu Pt 385, 100 Ω 630 °C až 800 °C CMC 0,23 °C RTD typu Pt 3926, 100 Ω -200 °C až 0 °C CMC 0,05 °C RTD typu Pt 3926, 100 Ω 0 °C až 100 °C CMC 0,07 °C RTD typu Pt 3926, 100 Ω 100 °C až 300 °C CMC 0,09 °C RTD typu Pt 3926, 100 Ω 300 °C až 400 °C CMC 0,10 °C RTD typu Pt 3926, 100 Ω 400 °C až 630 °C CMC 0,12 °C RTD typu Pt 3916, 100 Ω -200 °C až -190 °C CMC 0,25 °C RTD typu Pt 3916, 100 Ω -190 °C až -80 °C CMC 0,04 °C RTD typu Pt 3916, 100 Ω -80 °C až 0 °C CMC 0,05 °C RTD typu Pt 3916, 100 Ω 0 °C až 100 °C CMC 0,06 °C RTD typu Pt 3916, 100 Ω 100 °C až 260 °C CMC 0,07 °C RTD typu Pt 3916, 100 Ω 260 °C až 300 °C CMC 0,08 °C RTD typu Pt 3916, 100 Ω 300 °C až 400 °C CMC 0,09 °C RTD typu Pt 3916, 100 Ω 400 °C až 600 °C CMC 0,10 °C RTD typu Pt 3916, 100 Ω 600 °C až 630 °C CMC 0,23 °C RTD typu Pt 385, 200 Ω -200 °C až 100 °C CMC 0,04 °C RTD typu Pt 385, 200 Ω 100 °C až 260 °C CMC 0,05 °C RTD typu Pt 385, 200 Ω 260 °C až 300 °C CMC 0,12 °C RTD typu Pt 385, 200 Ω 300 °C až 400 °C CMC 0,13 °C RTD typu Pt 385, 200 Ω 400 °C až 600 °C CMC 0,14 °C RTD typu Pt 385, 200 Ω 600 °C až 630 °C CMC 0,16 °C RTD typu Pt 385, 500 Ω -200 °C až -80 °C CMC 0,04 °C RTD typu Pt 385, 500 Ω -80 °C až 100 °C CMC 0,05 °C RTD typu Pt 385, 500 Ω 100 °C až 260 °C CMC 0,06 °C RTD typu Pt 385, 500 Ω 260 °C až 400 °C CMC 0,08 °C RTD typu Pt 385, 500 Ω 400 °C až 600 °C CMC 0,09 °C RTD typu Pt 385, 500 Ω 600 °C až 630 °C CMC 0,11 °C RTD typu Pt 385, 1000 Ω -200 °C až 0 °C CMC 0,03 °C RTD typu Pt 385, 1000 Ω 0 °C až 100 °C CMC 0,04 °C RTD typu Pt 385, 1000 Ω 100 °C až 260 °C CMC 0,05 °C RTD typu Pt 385, 1000 Ω 260 °C až 300 °C CMC 0,06 °C RTD typu Pt 385, 1000 Ω 300 °C až 600 °C CMC 0,07 °C RTD typu Pt 385, 1000 Ω 600 °C až 630 °C CMC 0,23 °C RTD typu PtNi 385 120 Ω -80 °C až 100 °C CMC 0,08 °C RTD typu PtNi 385 120 Ω 100 °C až 260 °C CMC 0,14 °C Cu 427, 10 Ω -100 °C až 260 °C CMC 0,30 °C TP5, TP21 Temperatura / Wzorcowanie czesci elektrycznej przyrzadow do pomiaru temperatury za pomoca czujnikow RTD Wzorcowanie – temperatura Bezposrednie generowanie kalibratorem, generowanie rownowaznej rezystancji RTD typu Pt 385, 100 Ω od -200 °C do 0 °C CMC 0,05 °C RTD typu Pt 385, 100 Ω od 0 °C do 100 °C CMC 0,07 °C RTD typu Pt 385, 100 Ω od 100 °C do 300 °C CMC 0,09 °C RTD typu Pt 385, 100 Ω od 300 °C do 400 °C CMC 0,10 °C RTD typu Pt 385, 100 Ω od 400 °C do 630 °C CMC 0,12 °C RTD typu Pt 385, 100 Ω od 630 °C do 800 °C CMC 0,23 °C RTD typu Pt 3926, 100 Ω od -200 °C do 0 °C CMC 0,05 °C RTD typu Pt 3926, 100 Ω od 0 °C do 100 °C CMC 0,07 °C RTD typu Pt 3926, 100 Ω od 100 °C do 300 °C CMC 0,09 °C RTD typu Pt 3926, 100 Ω od 300 °C do 400 °C CMC 0,10 °C RTD typu Pt 3926, 100 Ω od 400 °C do 630 °C CMC 0,12 °C RTD typu Pt 3916, 100 Ω od -200 °C do -190 °C CMC 0,25 °C RTD typu Pt 3916, 100 Ω od -190 °C do -80 °C CMC 0,04 °C RTD typu Pt 3916, 100 Ω od -80 °C do 0 °C CMC 0,05 °C RTD typu Pt 3916, 100 Ω od 0 °C do 100 °C CMC 0,06 °C RTD typu Pt 3916, 100 Ω od 100 °C do 260 °C CMC 0,07 °C RTD typu Pt 3916, 100 Ω od 260 °C do 300 °C CMC 0,08 °C RTD typu Pt 3916, 100 Ω od 300 °C do 400 °C CMC 0,09 °C RTD typu Pt 3916, 100 Ω od 400 °C do 600 °C CMC 0,10 °C RTD typu Pt 3916, 100 Ω od 600 °C do 630 °C CMC 0,23 °C RTD typu Pt 385, 200 Ω od -200 °C do 100 °C CMC 0,04 °C RTD typu Pt 385, 200 Ω od 100 °C do 260 °C CMC 0,05 °C RTD typu Pt 385, 200 Ω od 260 °C do 300 °C CMC 0,12 °C RTD typu Pt 385, 200 Ω od 300 °C do 400 °C CMC 0,13 °C RTD typu Pt 385, 200 Ω od 400 °C do 600 °C CMC 0,14 °C RTD typu Pt 385, 200 Ω od 600 °C do 630 °C CMC 0,16 °C RTD typu Pt 385, 500 Ω od -200 °C do -80 °C CMC 0,04 °C RTD typu Pt 385, 500 Ω od -80 °C do 100 °C CMC 0,05 °C RTD typu Pt 385, 500 Ω od 100 °C do 260 °C CMC 0,06 °C RTD typu Pt 385, 500 Ω od 260 °C do 400 °C CMC 0,08 °C RTD typu Pt 385, 500 Ω od 400 °C do 600 °C CMC 0,09 °C RTD typu Pt 385, 500 Ω od 600 °C do 630 °C CMC 0,11 °C RTD typu Pt 385, 1000 Ω od -200 °C do 0 °C CMC 0,03 °C RTD typu Pt 385, 1000 Ω od 0 °C do 100 °C CMC 0,04 °C RTD typu Pt 385, 1000 Ω od 100 °C do 260 °C CMC 0,05 °C RTD typu Pt 385, 1000 Ω od 260 °C do 300 °C CMC 0,06 °C RTD typu Pt 385, 1000 Ω od 300 °C do 600 °C CMC 0,07 °C RTD typu Pt 385, 1000 Ω od 600 °C do 630 °C CMC 0,23 °C RTD typu PtNi 385 120 Ω od -80 °C do 100 °C CMC 0,08 °C RTD typu PtNi 385 120 Ω od 100 °C do 260 °C CMC 0,14 °C Cu 427, 10 Ω od -100 °C do 260 °C CMC 0,30 °C Teplota / Kalibrace elektricke casti meridel teploty pomoci RTD snimacu Kalibrace – teplota Prime generovani kalibratorem, generovani ekvivalentniho odporu RTD typu Pt 385, 100 Ω -200 °C az 0 °C CMC 0,05 °C RTD typu Pt 385, 100 Ω 0 °C az 100 °C CMC 0,07 °C RTD typu Pt 385, 100 Ω 100 °C az 300 °C CMC 0,09 °C RTD typu Pt 385, 100 Ω 300 °C az 400 °C CMC 0,10 °C RTD typu Pt 385, 100 Ω 400 °C az 630 °C CMC 0,12 °C RTD typu Pt 385, 100 Ω 630 °C az 800 °C CMC 0,23 °C RTD typu Pt 3926, 100 Ω -200 °C az 0 °C CMC 0,05 °C RTD typu Pt 3926, 100 Ω 0 °C az 100 °C CMC 0,07 °C RTD typu Pt 3926, 100 Ω 100 °C az 300 °C CMC 0,09 °C RTD typu Pt 3926, 100 Ω 300 °C az 400 °C CMC 0,10 °C RTD typu Pt 3926, 100 Ω 400 °C az 630 °C CMC 0,12 °C RTD typu Pt 3916, 100 Ω -200 °C az -190 °C CMC 0,25 °C RTD typu Pt 3916, 100 Ω -190 °C az -80 °C CMC 0,04 °C RTD typu Pt 3916, 100 Ω -80 °C az 0 °C CMC 0,05 °C RTD typu Pt 3916, 100 Ω 0 °C az 100 °C CMC 0,06 °C RTD typu Pt 3916, 100 Ω 100 °C az 260 °C CMC 0,07 °C RTD typu Pt 3916, 100 Ω 260 °C az 300 °C CMC 0,08 °C RTD typu Pt 3916, 100 Ω 300 °C az 400 °C CMC 0,09 °C RTD typu Pt 3916, 100 Ω 400 °C az 600 °C CMC 0,10 °C RTD typu Pt 3916, 100 Ω 600 °C az 630 °C CMC 0,23 °C RTD typu Pt 385, 200 Ω -200 °C az 100 °C CMC 0,04 °C RTD typu Pt 385, 200 Ω 100 °C az 260 °C CMC 0,05 °C RTD typu Pt 385, 200 Ω 260 °C az 300 °C CMC 0,12 °C RTD typu Pt 385, 200 Ω 300 °C az 400 °C CMC 0,13 °C RTD typu Pt 385, 200 Ω 400 °C az 600 °C CMC 0,14 °C RTD typu Pt 385, 200 Ω 600 °C az 630 °C CMC 0,16 °C RTD typu Pt 385, 500 Ω -200 °C az -80 °C CMC 0,04 °C RTD typu Pt 385, 500 Ω -80 °C az 100 °C CMC 0,05 °C RTD typu Pt 385, 500 Ω 100 °C az 260 °C CMC 0,06 °C RTD typu Pt 385, 500 Ω 260 °C az 400 °C CMC 0,08 °C RTD typu Pt 385, 500 Ω 400 °C az 600 °C CMC 0,09 °C RTD typu Pt 385, 500 Ω 600 °C az 630 °C CMC 0,11 °C RTD typu Pt 385, 1000 Ω -200 °C az 0 °C CMC 0,03 °C RTD typu Pt 385, 1000 Ω 0 °C az 100 °C CMC 0,04 °C RTD typu Pt 385, 1000 Ω 100 °C az 260 °C CMC 0,05 °C RTD typu Pt 385, 1000 Ω 260 °C az 300 °C CMC 0,06 °C RTD typu Pt 385, 1000 Ω 300 °C az 600 °C CMC 0,07 °C RTD typu Pt 385, 1000 Ω 600 °C az 630 °C CMC 0,23 °C RTD typu PtNi 385 120 Ω -80 °C az 100 °C CMC 0,08 °C RTD typu PtNi 385 120 Ω 100 °C az 260 °C CMC 0,14 °C Cu 427, 10 Ω -100 °C az 260 °C CMC 0,30 °C TP5, TP21","search_en":"Temperature / Calibration of electric part of thermometers using RTD sensors Calibration – temperature Direct generation by a calibrator, equivalent resistance generation RTD type Pt 385, 100 Ω -200 °C to 0 °C CMC 0,05 °C RTD type Pt 385, 100 Ω 0 °C to 100 °C CMC 0,07 °C RTD type Pt 385, 100 Ω 100 °C to 300 °C CMC 0,09 °C RTD type Pt 385, 100 Ω 300 °C to 400 °C CMC 0,10 °C RTD type Pt 385, 100 Ω 400 °C to 630 °C CMC 0,12 °C RTD type Pt 385, 100 Ω 630 °C to 800 °C CMC 0,23 °C RTD type Pt 3926, 100 Ω -200 °C to 0 °C CMC 0,05 °C RTD type Pt 3926, 100 Ω 0 °C to 100 °C CMC 0,07 °C RTD type Pt 3926, 100 Ω 100 °C to 300 °C CMC 0,09 °C RTD type Pt 3926, 100 Ω 300 °C to 400 °C CMC 0,10 °C RTD type Pt 3926, 100 Ω 400 °C to 630 °C CMC 0,12 °C RTD type Pt 3916, 100 Ω -200 °C to -190 °C CMC 0,25 °C RTD type Pt 3916, 100 Ω -190 °C to -80 °C CMC 0,04 °C RTD type Pt 3916, 100 Ω -80 °C to 0 °C CMC 0,05 °C RTD type Pt 3916, 100 Ω 0 °C to 100 °C CMC 0,06 °C RTD type Pt 3916, 100 Ω 100 °C to 260 °C CMC 0,07 °C RTD type Pt 3916, 100 Ω 260 °C to 300 °C CMC 0,08 °C RTD type Pt 3916, 100 Ω 300 °C to 400 °C CMC 0,09 °C RTD type Pt 3916, 100 Ω 400 °C to 600 °C CMC 0,10 °C RTD type Pt 3916, 100 Ω 600 °C to 630 °C CMC 0,23 °C RTD type Pt 385, 200 Ω -200 °C to 100 °C CMC 0,04 °C RTD type Pt 385, 200 Ω 100 °C to 260 °C CMC 0,05 °C RTD type Pt 385, 200 Ω 260 °C to 300 °C CMC 0,12 °C RTD type Pt 385, 200 Ω 300 °C to 400 °C CMC 0,13 °C RTD type Pt 385, 200 Ω 400 °C to 600 °C CMC 0,14 °C RTD type Pt 385, 200 Ω 600 °C to 630 °C CMC 0,16 °C RTD type Pt 385, 500 Ω -200 °C to -80 °C CMC 0,04 °C RTD type Pt 385, 500 Ω -80 °C to 100 °C CMC 0,05 °C RTD type Pt 385, 500 Ω 100 °C to 260 °C CMC 0,06 °C RTD type Pt 385, 500 Ω 260 °C to 400 °C CMC 0,08 °C RTD type Pt 385, 500 Ω 400 °C to 600 °C CMC 0,09 °C RTD type Pt 385, 500 Ω 600 °C to 630 °C CMC 0,11 °C RTD type Pt 385, 1000 Ω -200 °C to 0 °C CMC 0,03 °C RTD type Pt 385, 1000 Ω 0 °C to 100 °C CMC 0,04 °C RTD type Pt 385, 1000 Ω 100 °C to 260 °C CMC 0,05 °C RTD type Pt 385, 1000 Ω 260 °C to 300 °C CMC 0,06 °C RTD type Pt 385, 1000 Ω 300 °C to 600 °C CMC 0,07 °C RTD type Pt 385, 1000 Ω 600 °C to 630 °C CMC 0,23 °C RTD type PtNi 385 120 Ω -80 °C to 100 °C CMC 0,08 °C RTD type PtNi 385 120 Ω 100 °C to 260 °C CMC 0,14 °C Cu 427, 10 Ω -100 °C to 260 °C CMC 0,30 °C TP5, TP21","search_zh":"温度 / 使用 RTD 传感器的温度测量仪器电气部分校准 校准 – 温度 用校准器直接产生，产生等效电阻 Pt 385 型 RTD，100 Ω -200 °C 至 0 °C CMC 0,05 °C Pt 385 型 RTD，100 Ω 0 °C 至 100 °C CMC 0,07 °C Pt 385 型 RTD，100 Ω 100 °C 至 300 °C CMC 0,09 °C Pt 385 型 RTD，100 Ω 300 °C 至 400 °C CMC 0,10 °C Pt 385 型 RTD，100 Ω 400 °C 至 630 °C CMC 0,12 °C Pt 385 型 RTD，100 Ω 630 °C 至 800 °C CMC 0,23 °C Pt 3926 型 RTD，100 Ω -200 °C 至 0 °C CMC 0,05 °C Pt 3926 型 RTD，100 Ω 0 °C 至 100 °C CMC 0,07 °C Pt 3926 型 RTD，100 Ω 100 °C 至 300 °C CMC 0,09 °C Pt 3926 型 RTD，100 Ω 300 °C 至 400 °C CMC 0,10 °C Pt 3926 型 RTD，100 Ω 400 °C 至 630 °C CMC 0,12 °C Pt 3916 型 RTD，100 Ω -200 °C 至 -190 °C CMC 0,25 °C Pt 3916 型 RTD，100 Ω -190 °C 至 -80 °C CMC 0,04 °C Pt 3916 型 RTD，100 Ω -80 °C 至 0 °C CMC 0,05 °C Pt 3916 型 RTD，100 Ω 0 °C 至 100 °C CMC 0,06 °C Pt 3916 型 RTD，100 Ω 100 °C 至 260 °C CMC 0,07 °C Pt 3916 型 RTD，100 Ω 260 °C 至 300 °C CMC 0,08 °C Pt 3916 型 RTD，100 Ω 300 °C 至 400 °C CMC 0,09 °C Pt 3916 型 RTD，100 Ω 400 °C 至 600 °C CMC 0,10 °C Pt 3916 型 RTD，100 Ω 600 °C 至 630 °C CMC 0,23 °C Pt 385 型 RTD，200 Ω -200 °C 至 100 °C CMC 0,04 °C Pt 385 型 RTD，200 Ω 100 °C 至 260 °C CMC 0,05 °C Pt 385 型 RTD，200 Ω 260 °C 至 300 °C CMC 0,12 °C Pt 385 型 RTD，200 Ω 300 °C 至 400 °C CMC 0,13 °C Pt 385 型 RTD，200 Ω 400 °C 至 600 °C CMC 0,14 °C Pt 385 型 RTD，200 Ω 600 °C 至 630 °C CMC 0,16 °C Pt 385 型 RTD，500 Ω -200 °C 至 -80 °C CMC 0,04 °C Pt 385 型 RTD，500 Ω -80 °C 至 100 °C CMC 0,05 °C Pt 385 型 RTD，500 Ω 100 °C 至 260 °C CMC 0,06 °C Pt 385 型 RTD，500 Ω 260 °C 至 400 °C CMC 0,08 °C Pt 385 型 RTD，500 Ω 400 °C 至 600 °C CMC 0,09 °C Pt 385 型 RTD，500 Ω 600 °C 至 630 °C CMC 0,11 °C Pt 385 型 RTD，1000 Ω -200 °C 至 0 °C CMC 0,03 °C Pt 385 型 RTD，1000 Ω 0 °C 至 100 °C CMC 0,04 °C Pt 385 型 RTD，1000 Ω 100 °C 至 260 °C CMC 0,05 °C Pt 385 型 RTD，1000 Ω 260 °C 至 300 °C CMC 0,06 °C Pt 385 型 RTD，1000 Ω 300 °C 至 600 °C CMC 0,07 °C Pt 385 型 RTD，1000 Ω 600 °C 至 630 °C CMC 0,23 °C PtNi 385 型 RTD 120 Ω -80 °C 至 100 °C CMC 0,08 °C PtNi 385 型 RTD 120 Ω 100 °C 至 260 °C CMC 0,14 °C Cu 427, 10 Ω -100 °C 至 260 °C CMC 0,30 °C TP5, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ecda1ee21061328dc206cc23","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"6","test_object":"Temperatura / Wzorcowanie części elektrycznej symulatorów temperatury za pomocą czujników RTD","test_object_en":"Temperature / Calibration of electric part of temperature simulators using RTD sensors","test_object_zh":"温度 / 使用 RTD 传感器的温度模拟器电气部分校准","test_object_cs":"Teplota / Kalibrace elektrické části simulátorů teploty pomocí RTD snímačů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"PRT 25 Ω","range":"od -200 °C do 0 °C","cmc":"0,004 °C"},{"name":"PRT 25 Ω","range":"od 0 °C do 660 °C","cmc":"0,010 °C"},{"name":"PRT 100 Ω","range":"od -200 °C do 0 °C","cmc":"0,003 °C"},{"name":"PRT 100 Ω","range":"od 0 °C do 232 °C","cmc":"0,005 °C"},{"name":"PRT 100 Ω","range":"od 232 °C do 400 °C","cmc":"0,007 °C"},{"name":"PRT 100 Ω","range":"od 400 °C do 660 °C","cmc":"0,50 °C"}],"parameters_en":[{"name":"PRT 25 Ω","range":"-200 °C to 0 °C","cmc":"0,004 °C"},{"name":"PRT 25 Ω","range":"0 °C to 660 °C","cmc":"0,010 °C"},{"name":"PRT 100 Ω","range":"-200 °C to 0 °C","cmc":"0,003 °C"},{"name":"PRT 100 Ω","range":"0 °C to 232 °C","cmc":"0,005 °C"},{"name":"PRT 100 Ω","range":"232 °C to 400 °C","cmc":"0,007 °C"},{"name":"PRT 100 Ω","range":"400 °C to 660 °C","cmc":"0,50 °C"}],"parameters_zh":[{"name":"PRT 25 Ω","range":"-200 °C 至 0 °C","cmc":"0,004 °C"},{"name":"PRT 25 Ω","range":"0 °C 至 660 °C","cmc":"0,010 °C"},{"name":"PRT 100 Ω","range":"-200 °C 至 0 °C","cmc":"0,003 °C"},{"name":"PRT 100 Ω","range":"0 °C 至 232 °C","cmc":"0,005 °C"},{"name":"PRT 100 Ω","range":"232 °C 至 400 °C","cmc":"0,007 °C"},{"name":"PRT 100 Ω","range":"400 °C 至 660 °C","cmc":"0,50 °C"}],"parameters_cs":[{"name":"PRT 25 Ω","range":"-200 °C až 0 °C","cmc":"0,004 °C"},{"name":"PRT 25 Ω","range":"0 °C až 660 °C","cmc":"0,010 °C"},{"name":"PRT 100 Ω","range":"-200 °C až 0 °C","cmc":"0,003 °C"},{"name":"PRT 100 Ω","range":"0 °C až 232 °C","cmc":"0,005 °C"},{"name":"PRT 100 Ω","range":"232 °C až 400 °C","cmc":"0,007 °C"},{"name":"PRT 100 Ω","range":"400 °C až 660 °C","cmc":"0,50 °C"}],"technique":"Pomiar bezpośredni multimetrem, pomiar równoważnej rezystancji","technique_en":"Direct measurement by a multimeter, equivalent resistance measurement","technique_zh":"用万用表直接测量，测量等效电阻","technique_cs":"Přímé měření multimetrem, měření ekvivalentního odporu","techniques":["Pomiar bezpośredni multimetrem, pomiar równoważnej rezystancji"],"techniques_en":["Direct measurement by a multimeter, equivalent resistance measurement"],"techniques_zh":["用万用表直接测量，测量等效电阻"],"techniques_cs":["Přímé měření multimetrem, měření ekvivalentního odporu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nPRT 25 Ω od -200 °C do 0 °C CMC 0,004 °C\nPRT 25 Ω od 0 °C do 660 °C CMC 0,010 °C\nPRT 100 Ω od -200 °C do 0 °C CMC 0,003 °C\nPRT 100 Ω od 0 °C do 232 °C CMC 0,005 °C\nPRT 100 Ω od 232 °C do 400 °C CMC 0,007 °C\nPRT 100 Ω od 400 °C do 660 °C CMC 0,50 °C\nPomiar bezpośredni multimetrem, pomiar równoważnej rezystancji","reference":"TP5, TP21","norm_bases":["TP5","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Temperatura / Wzorcowanie części elektrycznej symulatorów temperatury za pomocą czujników RTD Wzorcowanie – temperatura Pomiar bezpośredni multimetrem, pomiar równoważnej rezystancji PRT 25 Ω od -200 °C do 0 °C CMC 0,004 °C PRT 25 Ω od 0 °C do 660 °C CMC 0,010 °C PRT 100 Ω od -200 °C do 0 °C CMC 0,003 °C PRT 100 Ω od 0 °C do 232 °C CMC 0,005 °C PRT 100 Ω od 232 °C do 400 °C CMC 0,007 °C PRT 100 Ω od 400 °C do 660 °C CMC 0,50 °C Teplota / Kalibrace elektrické části simulátorů teploty pomocí RTD snímačů Kalibrace – teplota Přímé měření multimetrem, měření ekvivalentního odporu PRT 25 Ω -200 °C až 0 °C CMC 0,004 °C PRT 25 Ω 0 °C až 660 °C CMC 0,010 °C PRT 100 Ω -200 °C až 0 °C CMC 0,003 °C PRT 100 Ω 0 °C až 232 °C CMC 0,005 °C PRT 100 Ω 232 °C až 400 °C CMC 0,007 °C PRT 100 Ω 400 °C až 660 °C CMC 0,50 °C TP5, TP21 Temperatura / Wzorcowanie czesci elektrycznej symulatorow temperatury za pomoca czujnikow RTD Wzorcowanie – temperatura Pomiar bezposredni multimetrem, pomiar rownowaznej rezystancji PRT 25 Ω od -200 °C do 0 °C CMC 0,004 °C PRT 25 Ω od 0 °C do 660 °C CMC 0,010 °C PRT 100 Ω od -200 °C do 0 °C CMC 0,003 °C PRT 100 Ω od 0 °C do 232 °C CMC 0,005 °C PRT 100 Ω od 232 °C do 400 °C CMC 0,007 °C PRT 100 Ω od 400 °C do 660 °C CMC 0,50 °C Teplota / Kalibrace elektricke casti simulatoru teploty pomoci RTD snimacu Kalibrace – teplota Prime mereni multimetrem, mereni ekvivalentniho odporu PRT 25 Ω -200 °C az 0 °C CMC 0,004 °C PRT 25 Ω 0 °C az 660 °C CMC 0,010 °C PRT 100 Ω -200 °C az 0 °C CMC 0,003 °C PRT 100 Ω 0 °C az 232 °C CMC 0,005 °C PRT 100 Ω 232 °C az 400 °C CMC 0,007 °C PRT 100 Ω 400 °C az 660 °C CMC 0,50 °C TP5, TP21","search_en":"Temperature / Calibration of electric part of temperature simulators using RTD sensors Calibration – temperature Direct measurement by a multimeter, equivalent resistance measurement PRT 25 Ω -200 °C to 0 °C CMC 0,004 °C PRT 25 Ω 0 °C to 660 °C CMC 0,010 °C PRT 100 Ω -200 °C to 0 °C CMC 0,003 °C PRT 100 Ω 0 °C to 232 °C CMC 0,005 °C PRT 100 Ω 232 °C to 400 °C CMC 0,007 °C PRT 100 Ω 400 °C to 660 °C CMC 0,50 °C TP5, TP21","search_zh":"温度 / 使用 RTD 传感器的温度模拟器电气部分校准 校准 – 温度 用万用表直接测量，测量等效电阻 PRT 25 Ω -200 °C 至 0 °C CMC 0,004 °C PRT 25 Ω 0 °C 至 660 °C CMC 0,010 °C PRT 100 Ω -200 °C 至 0 °C CMC 0,003 °C PRT 100 Ω 0 °C 至 232 °C CMC 0,005 °C PRT 100 Ω 232 °C 至 400 °C CMC 0,007 °C PRT 100 Ω 400 °C 至 660 °C CMC 0,50 °C TP5, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f14548ecf1296564ebb4929e","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Źródła napięcia stałego","test_object_en":"DC voltage / DC voltage sources","test_object_zh":"直流电压 / 直流电压源","test_object_cs":"Stejnosměrné napětí / Zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 20 mV","cmc":"0,20 µV"},{"name":"","range":"od 20 mV do 30 mV","cmc":"0,00096 %"},{"name":"","range":"od 30 mV do 40 mV","cmc":"0,00079 %"},{"name":"","range":"od 40 mV do 50 mV","cmc":"0,00071 %"},{"name":"","range":"od 50 mV do 90 mV","cmc":"0,00066 %"},{"name":"","range":"od 90 mV do 190 mV","cmc":"0,00057 %"},{"name":"","range":"od 190 mV do 300 mV","cmc":"0,00051 %"},{"name":"","range":"od 300 mV do 500 mV","cmc":"0,00044 %"},{"name":"","range":"od 500 mV do 1 V","cmc":"0,00039 %"},{"name":"","range":"od 1 V do 2 V","cmc":"0,00035 %"},{"name":"","range":"od 2 V do 3 V","cmc":"0,00051 %"},{"name":"","range":"od 3 V do 5 V","cmc":"0,00044 %"},{"name":"","range":"od 5 V do 10 V","cmc":"0,00039 %"},{"name":"","range":"od 10 V do 20 V","cmc":"0,00035 %"},{"name":"","range":"od 20 V do 30 V","cmc":"0,00066 %"},{"name":"","range":"od 30 V do 50 V","cmc":"0,00059 %"},{"name":"","range":"od 50 V do 100 V","cmc":"0,00054 %"},{"name":"","range":"od 100 V do 200 V","cmc":"0,00050 %"},{"name":"","range":"od 200 V do 250 V","cmc":"0,00071 %"},{"name":"","range":"od 250 V do 400 V","cmc":"0,00066 %"},{"name":"","range":"od 400 V do 600 V","cmc":"0,00059 %"},{"name":"","range":"od 600 V do 1050 V","cmc":"0,00054 %"}],"parameters_en":[{"name":"","range":"0 mV to 20 mV","cmc":"0,20 µV"},{"name":"","range":"20 mV to 30 mV","cmc":"0,00096 %"},{"name":"","range":"30 mV to 40 mV","cmc":"0,00079 %"},{"name":"","range":"40 mV to 50 mV","cmc":"0,00071 %"},{"name":"","range":"50 mV to 90 mV","cmc":"0,00066 %"},{"name":"","range":"90 mV to 190 mV","cmc":"0,00057 %"},{"name":"","range":"190 mV to 300 mV","cmc":"0,00051 %"},{"name":"","range":"300 mV to 500 mV","cmc":"0,00044 %"},{"name":"","range":"500 mV to 1 V","cmc":"0,00039 %"},{"name":"","range":"1 V to 2 V","cmc":"0,00035 %"},{"name":"","range":"2 V to 3 V","cmc":"0,00051 %"},{"name":"","range":"3 V to 5 V","cmc":"0,00044 %"},{"name":"","range":"5 V to 10 V","cmc":"0,00039 %"},{"name":"","range":"10 V to 20 V","cmc":"0,00035 %"},{"name":"","range":"20 V to 30 V","cmc":"0,00066 %"},{"name":"","range":"30 V to 50 V","cmc":"0,00059 %"},{"name":"","range":"50 V to 100 V","cmc":"0,00054 %"},{"name":"","range":"100 V to 200 V","cmc":"0,00050 %"},{"name":"","range":"200 V to 250 V","cmc":"0,00071 %"},{"name":"","range":"250 V to 400 V","cmc":"0,00066 %"},{"name":"","range":"400 V to 600 V","cmc":"0,00059 %"},{"name":"","range":"600 V to 1050 V","cmc":"0,00054 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 20 mV","cmc":"0,20 µV"},{"name":"","range":"20 mV 至 30 mV","cmc":"0,00096 %"},{"name":"","range":"30 mV 至 40 mV","cmc":"0,00079 %"},{"name":"","range":"40 mV 至 50 mV","cmc":"0,00071 %"},{"name":"","range":"50 mV 至 90 mV","cmc":"0,00066 %"},{"name":"","range":"90 mV 至 190 mV","cmc":"0,00057 %"},{"name":"","range":"190 mV 至 300 mV","cmc":"0,00051 %"},{"name":"","range":"300 mV 至 500 mV","cmc":"0,00044 %"},{"name":"","range":"500 mV 至 1 V","cmc":"0,00039 %"},{"name":"","range":"1 V 至 2 V","cmc":"0,00035 %"},{"name":"","range":"2 V 至 3 V","cmc":"0,00051 %"},{"name":"","range":"3 V 至 5 V","cmc":"0,00044 %"},{"name":"","range":"5 V 至 10 V","cmc":"0,00039 %"},{"name":"","range":"10 V 至 20 V","cmc":"0,00035 %"},{"name":"","range":"20 V 至 30 V","cmc":"0,00066 %"},{"name":"","range":"30 V 至 50 V","cmc":"0,00059 %"},{"name":"","range":"50 V 至 100 V","cmc":"0,00054 %"},{"name":"","range":"100 V 至 200 V","cmc":"0,00050 %"},{"name":"","range":"200 V 至 250 V","cmc":"0,00071 %"},{"name":"","range":"250 V 至 400 V","cmc":"0,00066 %"},{"name":"","range":"400 V 至 600 V","cmc":"0,00059 %"},{"name":"","range":"600 V 至 1050 V","cmc":"0,00054 %"}],"parameters_cs":[{"name":"","range":"0 mV až 20 mV","cmc":"0,20 µV"},{"name":"","range":"20 mV až 30 mV","cmc":"0,00096 %"},{"name":"","range":"30 mV až 40 mV","cmc":"0,00079 %"},{"name":"","range":"40 mV až 50 mV","cmc":"0,00071 %"},{"name":"","range":"50 mV až 90 mV","cmc":"0,00066 %"},{"name":"","range":"90 mV až 190 mV","cmc":"0,00057 %"},{"name":"","range":"190 mV až 300 mV","cmc":"0,00051 %"},{"name":"","range":"300 mV až 500 mV","cmc":"0,00044 %"},{"name":"","range":"500 mV až 1 V","cmc":"0,00039 %"},{"name":"","range":"1 V až 2 V","cmc":"0,00035 %"},{"name":"","range":"2 V až 3 V","cmc":"0,00051 %"},{"name":"","range":"3 V až 5 V","cmc":"0,00044 %"},{"name":"","range":"5 V až 10 V","cmc":"0,00039 %"},{"name":"","range":"10 V až 20 V","cmc":"0,00035 %"},{"name":"","range":"20 V až 30 V","cmc":"0,00066 %"},{"name":"","range":"30 V až 50 V","cmc":"0,00059 %"},{"name":"","range":"50 V až 100 V","cmc":"0,00054 %"},{"name":"","range":"100 V až 200 V","cmc":"0,00050 %"},{"name":"","range":"200 V až 250 V","cmc":"0,00071 %"},{"name":"","range":"250 V až 400 V","cmc":"0,00066 %"},{"name":"","range":"400 V až 600 V","cmc":"0,00059 %"},{"name":"","range":"600 V až 1050 V","cmc":"0,00054 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 20 mV CMC 0,20 µV\nod 20 mV do 30 mV CMC 0,00096 %\nod 30 mV do 40 mV CMC 0,00079 %\nod 40 mV do 50 mV CMC 0,00071 %\nod 50 mV do 90 mV CMC 0,00066 %\nod 90 mV do 190 mV CMC 0,00057 %\nod 190 mV do 300 mV CMC 0,00051 %\nod 300 mV do 500 mV CMC 0,00044 %\nod 500 mV do 1 V CMC 0,00039 %\nod 1 V do 2 V CMC 0,00035 %\nod 2 V do 3 V CMC 0,00051 %\nod 3 V do 5 V CMC 0,00044 %\nod 5 V do 10 V CMC 0,00039 %\nod 10 V do 20 V CMC 0,00035 %\nod 20 V do 30 V CMC 0,00066 %\nod 30 V do 50 V CMC 0,00059 %\nod 50 V do 100 V CMC 0,00054 %\nod 100 V do 200 V CMC 0,00050 %\nod 200 V do 250 V CMC 0,00071 %\nod 250 V do 400 V CMC 0,00066 %\nod 400 V do 600 V CMC 0,00059 %\nod 600 V do 1050 V CMC 0,00054 %\nPomiar bezpośredni multimetrem","reference":"TP1, TP21","norm_bases":["TP1","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Źródła napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 mV do 20 mV CMC 0,20 µV od 20 mV do 30 mV CMC 0,00096 % od 30 mV do 40 mV CMC 0,00079 % od 40 mV do 50 mV CMC 0,00071 % od 50 mV do 90 mV CMC 0,00066 % od 90 mV do 190 mV CMC 0,00057 % od 190 mV do 300 mV CMC 0,00051 % od 300 mV do 500 mV CMC 0,00044 % od 500 mV do 1 V CMC 0,00039 % od 1 V do 2 V CMC 0,00035 % od 2 V do 3 V CMC 0,00051 % od 3 V do 5 V CMC 0,00044 % od 5 V do 10 V CMC 0,00039 % od 10 V do 20 V CMC 0,00035 % od 20 V do 30 V CMC 0,00066 % od 30 V do 50 V CMC 0,00059 % od 50 V do 100 V CMC 0,00054 % od 100 V do 200 V CMC 0,00050 % od 200 V do 250 V CMC 0,00071 % od 250 V do 400 V CMC 0,00066 % od 400 V do 600 V CMC 0,00059 % od 600 V do 1050 V CMC 0,00054 % Stejnosměrné napětí / Zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 0 mV až 20 mV CMC 0,20 µV 20 mV až 30 mV CMC 0,00096 % 30 mV až 40 mV CMC 0,00079 % 40 mV až 50 mV CMC 0,00071 % 50 mV až 90 mV CMC 0,00066 % 90 mV až 190 mV CMC 0,00057 % 190 mV až 300 mV CMC 0,00051 % 300 mV až 500 mV CMC 0,00044 % 500 mV až 1 V CMC 0,00039 % 1 V až 2 V CMC 0,00035 % 2 V až 3 V CMC 0,00051 % 3 V až 5 V CMC 0,00044 % 5 V až 10 V CMC 0,00039 % 10 V až 20 V CMC 0,00035 % 20 V až 30 V CMC 0,00066 % 30 V až 50 V CMC 0,00059 % 50 V až 100 V CMC 0,00054 % 100 V až 200 V CMC 0,00050 % 200 V až 250 V CMC 0,00071 % 250 V až 400 V CMC 0,00066 % 400 V až 600 V CMC 0,00059 % 600 V až 1050 V CMC 0,00054 % TP1, TP21 Napiecie stale / Zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 mV do 20 mV CMC 0,20 µV od 20 mV do 30 mV CMC 0,00096 % od 30 mV do 40 mV CMC 0,00079 % od 40 mV do 50 mV CMC 0,00071 % od 50 mV do 90 mV CMC 0,00066 % od 90 mV do 190 mV CMC 0,00057 % od 190 mV do 300 mV CMC 0,00051 % od 300 mV do 500 mV CMC 0,00044 % od 500 mV do 1 V CMC 0,00039 % od 1 V do 2 V CMC 0,00035 % od 2 V do 3 V CMC 0,00051 % od 3 V do 5 V CMC 0,00044 % od 5 V do 10 V CMC 0,00039 % od 10 V do 20 V CMC 0,00035 % od 20 V do 30 V CMC 0,00066 % od 30 V do 50 V CMC 0,00059 % od 50 V do 100 V CMC 0,00054 % od 100 V do 200 V CMC 0,00050 % od 200 V do 250 V CMC 0,00071 % od 250 V do 400 V CMC 0,00066 % od 400 V do 600 V CMC 0,00059 % od 600 V do 1050 V CMC 0,00054 % Stejnosmerne napeti / Zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 0 mV az 20 mV CMC 0,20 µV 20 mV az 30 mV CMC 0,00096 % 30 mV az 40 mV CMC 0,00079 % 40 mV az 50 mV CMC 0,00071 % 50 mV az 90 mV CMC 0,00066 % 90 mV az 190 mV CMC 0,00057 % 190 mV az 300 mV CMC 0,00051 % 300 mV az 500 mV CMC 0,00044 % 500 mV az 1 V CMC 0,00039 % 1 V az 2 V CMC 0,00035 % 2 V az 3 V CMC 0,00051 % 3 V az 5 V CMC 0,00044 % 5 V az 10 V CMC 0,00039 % 10 V az 20 V CMC 0,00035 % 20 V az 30 V CMC 0,00066 % 30 V az 50 V CMC 0,00059 % 50 V az 100 V CMC 0,00054 % 100 V az 200 V CMC 0,00050 % 200 V az 250 V CMC 0,00071 % 250 V az 400 V CMC 0,00066 % 400 V az 600 V CMC 0,00059 % 600 V az 1050 V CMC 0,00054 % TP1, TP21","search_en":"DC voltage / DC voltage sources Calibration – electrical quantities Direct measurement using a multimeter 0 mV to 20 mV CMC 0,20 µV 20 mV to 30 mV CMC 0,00096 % 30 mV to 40 mV CMC 0,00079 % 40 mV to 50 mV CMC 0,00071 % 50 mV to 90 mV CMC 0,00066 % 90 mV to 190 mV CMC 0,00057 % 190 mV to 300 mV CMC 0,00051 % 300 mV to 500 mV CMC 0,00044 % 500 mV to 1 V CMC 0,00039 % 1 V to 2 V CMC 0,00035 % 2 V to 3 V CMC 0,00051 % 3 V to 5 V CMC 0,00044 % 5 V to 10 V CMC 0,00039 % 10 V to 20 V CMC 0,00035 % 20 V to 30 V CMC 0,00066 % 30 V to 50 V CMC 0,00059 % 50 V to 100 V CMC 0,00054 % 100 V to 200 V CMC 0,00050 % 200 V to 250 V CMC 0,00071 % 250 V to 400 V CMC 0,00066 % 400 V to 600 V CMC 0,00059 % 600 V to 1050 V CMC 0,00054 % TP1, TP21","search_zh":"直流电压 / 直流电压源 校准 – 电学量 用万用表直接测量 0 mV 至 20 mV CMC 0,20 µV 20 mV 至 30 mV CMC 0,00096 % 30 mV 至 40 mV CMC 0,00079 % 40 mV 至 50 mV CMC 0,00071 % 50 mV 至 90 mV CMC 0,00066 % 90 mV 至 190 mV CMC 0,00057 % 190 mV 至 300 mV CMC 0,00051 % 300 mV 至 500 mV CMC 0,00044 % 500 mV 至 1 V CMC 0,00039 % 1 V 至 2 V CMC 0,00035 % 2 V 至 3 V CMC 0,00051 % 3 V 至 5 V CMC 0,00044 % 5 V 至 10 V CMC 0,00039 % 10 V 至 20 V CMC 0,00035 % 20 V 至 30 V CMC 0,00066 % 30 V 至 50 V CMC 0,00059 % 50 V 至 100 V CMC 0,00054 % 100 V 至 200 V CMC 0,00050 % 200 V 至 250 V CMC 0,00071 % 250 V 至 400 V CMC 0,00066 % 400 V 至 600 V CMC 0,00059 % 600 V 至 1050 V CMC 0,00054 % TP1, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7af2fafe0e4dfceedd8e0824","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / Mierniki napięcia stałego, części elektryczne pH-metrów","test_object_en":"DC voltage / DC voltage meters, electrical parts of pH meters","test_object_zh":"直流电压 / 直流电压测量仪器、pH 计电气部分","test_object_cs":"Stejnosměrné napětí / Měřidla stejnosměrného napětí, elektrické části pH metrů","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 20 mV","cmc":"0,8 µV"},{"name":"","range":"od 20 mV do 25 mV","cmc":"0,0039 %"},{"name":"","range":"od 25 mV do 30 mV","cmc":"0,0033 %"},{"name":"","range":"od 30 mV do 35 mV","cmc":"0,0029 %"},{"name":"","range":"od 35 mV do 45 mV","cmc":"0,0026 %"},{"name":"","range":"od 45 mV do 70 mV","cmc":"0,0022 %"},{"name":"","range":"od 70 mV do 100 mV","cmc":"0,0017 %"},{"name":"","range":"od 100 mV do 150 mV","cmc":"0,0015 %"},{"name":"","range":"od 150 mV do 300 mV","cmc":"0,0013 %"},{"name":"","range":"od 300 mV do 400 mV","cmc":"0,0011 %"},{"name":"","range":"od 400 mV do 500 mV","cmc":"0,00097 %"},{"name":"","range":"od 500 mV do 1 V","cmc":"0,00092 %"},{"name":"","range":"od 1 V do 1,5 V","cmc":"0,00082 %"},{"name":"","range":"od 1,5 V do 2,2 V","cmc":"0,00079 %"},{"name":"","range":"od 2,2 V do 3 V","cmc":"0,00087 %"},{"name":"","range":"od 3 V do 4,5 V","cmc":"0,00083 %"},{"name":"","range":"od 4,5 V do 9 V","cmc":"0,00079 %"},{"name":"","range":"od 9 V do 11 V","cmc":"0,00075 %"},{"name":"","range":"od 11 V do 22 V","cmc":"0,00077 %"},{"name":"","range":"od 22 V do 45 V","cmc":"0,0012 %"},{"name":"","range":"od 45 V do 60 V","cmc":"0,0010 %"},{"name":"","range":"od 60 V do 100 V","cmc":"0,00095 %"},{"name":"","range":"od 100 V do 150 V","cmc":"0,00090 %"},{"name":"","range":"od 150 V do 220 V","cmc":"0,00087 %"},{"name":"","range":"od 220 V do 350 V","cmc":"0,0012 %"},{"name":"","range":"od 350 V do 1100 V","cmc":"0,0011 %"}],"parameters_en":[{"name":"","range":"0 mV to 20 mV","cmc":"0,8 µV"},{"name":"","range":"20 mV to 25 mV","cmc":"0,0039 %"},{"name":"","range":"25 mV to 30 mV","cmc":"0,0033 %"},{"name":"","range":"30 mV to 35 mV","cmc":"0,0029 %"},{"name":"","range":"35 mV to 45 mV","cmc":"0,0026 %"},{"name":"","range":"45 mV to 70 mV","cmc":"0,0022 %"},{"name":"","range":"70 mV to 100 mV","cmc":"0,0017 %"},{"name":"","range":"100 mV to 150 mV","cmc":"0,0015 %"},{"name":"","range":"150 mV to 300 mV","cmc":"0,0013 %"},{"name":"","range":"300 mV to 400 mV","cmc":"0,0011 %"},{"name":"","range":"400 mV to 500 mV","cmc":"0,00097 %"},{"name":"","range":"500 mV to 1 V","cmc":"0,00092 %"},{"name":"","range":"1 V to 1,5 V","cmc":"0,00082 %"},{"name":"","range":"1,5 V to 2,2 V","cmc":"0,00079 %"},{"name":"","range":"2,2 V to 3 V","cmc":"0,00087 %"},{"name":"","range":"3 V to 4,5 V","cmc":"0,00083 %"},{"name":"","range":"4,5 V to 9 V","cmc":"0,00079 %"},{"name":"","range":"9 V to 11 V","cmc":"0,00075 %"},{"name":"","range":"11 V to 22 V","cmc":"0,00077 %"},{"name":"","range":"22 V to 45 V","cmc":"0,0012 %"},{"name":"","range":"45 V to 60 V","cmc":"0,0010 %"},{"name":"","range":"60 V to 100 V","cmc":"0,00095 %"},{"name":"","range":"100 V to 150 V","cmc":"0,00090 %"},{"name":"","range":"150 V to 220 V","cmc":"0,00087 %"},{"name":"","range":"220 V to 350 V","cmc":"0,0012 %"},{"name":"","range":"350 V to 1100 V","cmc":"0,0011 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 20 mV","cmc":"0,8 µV"},{"name":"","range":"20 mV 至 25 mV","cmc":"0,0039 %"},{"name":"","range":"25 mV 至 30 mV","cmc":"0,0033 %"},{"name":"","range":"30 mV 至 35 mV","cmc":"0,0029 %"},{"name":"","range":"35 mV 至 45 mV","cmc":"0,0026 %"},{"name":"","range":"45 mV 至 70 mV","cmc":"0,0022 %"},{"name":"","range":"70 mV 至 100 mV","cmc":"0,0017 %"},{"name":"","range":"100 mV 至 150 mV","cmc":"0,0015 %"},{"name":"","range":"150 mV 至 300 mV","cmc":"0,0013 %"},{"name":"","range":"300 mV 至 400 mV","cmc":"0,0011 %"},{"name":"","range":"400 mV 至 500 mV","cmc":"0,00097 %"},{"name":"","range":"500 mV 至 1 V","cmc":"0,00092 %"},{"name":"","range":"1 V 至 1,5 V","cmc":"0,00082 %"},{"name":"","range":"1,5 V 至 2,2 V","cmc":"0,00079 %"},{"name":"","range":"2,2 V 至 3 V","cmc":"0,00087 %"},{"name":"","range":"3 V 至 4,5 V","cmc":"0,00083 %"},{"name":"","range":"4,5 V 至 9 V","cmc":"0,00079 %"},{"name":"","range":"9 V 至 11 V","cmc":"0,00075 %"},{"name":"","range":"11 V 至 22 V","cmc":"0,00077 %"},{"name":"","range":"22 V 至 45 V","cmc":"0,0012 %"},{"name":"","range":"45 V 至 60 V","cmc":"0,0010 %"},{"name":"","range":"60 V 至 100 V","cmc":"0,00095 %"},{"name":"","range":"100 V 至 150 V","cmc":"0,00090 %"},{"name":"","range":"150 V 至 220 V","cmc":"0,00087 %"},{"name":"","range":"220 V 至 350 V","cmc":"0,0012 %"},{"name":"","range":"350 V 至 1100 V","cmc":"0,0011 %"}],"parameters_cs":[{"name":"","range":"0 mV až 20 mV","cmc":"0,8 µV"},{"name":"","range":"20 mV až 25 mV","cmc":"0,0039 %"},{"name":"","range":"25 mV až 30 mV","cmc":"0,0033 %"},{"name":"","range":"30 mV až 35 mV","cmc":"0,0029 %"},{"name":"","range":"35 mV až 45 mV","cmc":"0,0026 %"},{"name":"","range":"45 mV až 70 mV","cmc":"0,0022 %"},{"name":"","range":"70 mV až 100 mV","cmc":"0,0017 %"},{"name":"","range":"100 mV až 150 mV","cmc":"0,0015 %"},{"name":"","range":"150 mV až 300 mV","cmc":"0,0013 %"},{"name":"","range":"300 mV až 400 mV","cmc":"0,0011 %"},{"name":"","range":"400 mV až 500 mV","cmc":"0,00097 %"},{"name":"","range":"500 mV až 1 V","cmc":"0,00092 %"},{"name":"","range":"1 V až 1,5 V","cmc":"0,00082 %"},{"name":"","range":"1,5 V až 2,2 V","cmc":"0,00079 %"},{"name":"","range":"2,2 V až 3 V","cmc":"0,00087 %"},{"name":"","range":"3 V až 4,5 V","cmc":"0,00083 %"},{"name":"","range":"4,5 V až 9 V","cmc":"0,00079 %"},{"name":"","range":"9 V až 11 V","cmc":"0,00075 %"},{"name":"","range":"11 V až 22 V","cmc":"0,00077 %"},{"name":"","range":"22 V až 45 V","cmc":"0,0012 %"},{"name":"","range":"45 V až 60 V","cmc":"0,0010 %"},{"name":"","range":"60 V až 100 V","cmc":"0,00095 %"},{"name":"","range":"100 V až 150 V","cmc":"0,00090 %"},{"name":"","range":"150 V až 220 V","cmc":"0,00087 %"},{"name":"","range":"220 V až 350 V","cmc":"0,0012 %"},{"name":"","range":"350 V až 1100 V","cmc":"0,0011 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 20 mV CMC 0,8 µV\nod 20 mV do 25 mV CMC 0,0039 %\nod 25 mV do 30 mV CMC 0,0033 %\nod 30 mV do 35 mV CMC 0,0029 %\nod 35 mV do 45 mV CMC 0,0026 %\nod 45 mV do 70 mV CMC 0,0022 %\nod 70 mV do 100 mV CMC 0,0017 %\nod 100 mV do 150 mV CMC 0,0015 %\nod 150 mV do 300 mV CMC 0,0013 %\nod 300 mV do 400 mV CMC 0,0011 %\nod 400 mV do 500 mV CMC 0,00097 %\nod 500 mV do 1 V CMC 0,00092 %\nod 1 V do 1,5 V CMC 0,00082 %\nod 1,5 V do 2,2 V CMC 0,00079 %\nod 2,2 V do 3 V CMC 0,00087 %\nod 3 V do 4,5 V CMC 0,00083 %\nod 4,5 V do 9 V CMC 0,00079 %\nod 9 V do 11 V CMC 0,00075 %\nod 11 V do 22 V CMC 0,00077 %\nod 22 V do 45 V CMC 0,0012 %\nod 45 V do 60 V CMC 0,0010 %\nod 60 V do 100 V CMC 0,00095 %\nod 100 V do 150 V CMC 0,00090 %\nod 150 V do 220 V CMC 0,00087 %\nod 220 V do 350 V CMC 0,0012 %\nod 350 V do 1100 V CMC 0,0011 %\nBezpośrednie generowanie kalibratorem","reference":"TP1, TP21","norm_bases":["TP1","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / Mierniki napięcia stałego, części elektryczne pH-metrów Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 mV do 20 mV CMC 0,8 µV od 20 mV do 25 mV CMC 0,0039 % od 25 mV do 30 mV CMC 0,0033 % od 30 mV do 35 mV CMC 0,0029 % od 35 mV do 45 mV CMC 0,0026 % od 45 mV do 70 mV CMC 0,0022 % od 70 mV do 100 mV CMC 0,0017 % od 100 mV do 150 mV CMC 0,0015 % od 150 mV do 300 mV CMC 0,0013 % od 300 mV do 400 mV CMC 0,0011 % od 400 mV do 500 mV CMC 0,00097 % od 500 mV do 1 V CMC 0,00092 % od 1 V do 1,5 V CMC 0,00082 % od 1,5 V do 2,2 V CMC 0,00079 % od 2,2 V do 3 V CMC 0,00087 % od 3 V do 4,5 V CMC 0,00083 % od 4,5 V do 9 V CMC 0,00079 % od 9 V do 11 V CMC 0,00075 % od 11 V do 22 V CMC 0,00077 % od 22 V do 45 V CMC 0,0012 % od 45 V do 60 V CMC 0,0010 % od 60 V do 100 V CMC 0,00095 % od 100 V do 150 V CMC 0,00090 % od 150 V do 220 V CMC 0,00087 % od 220 V do 350 V CMC 0,0012 % od 350 V do 1100 V CMC 0,0011 % Stejnosměrné napětí / Měřidla stejnosměrného napětí, elektrické části pH metrů Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 mV až 20 mV CMC 0,8 µV 20 mV až 25 mV CMC 0,0039 % 25 mV až 30 mV CMC 0,0033 % 30 mV až 35 mV CMC 0,0029 % 35 mV až 45 mV CMC 0,0026 % 45 mV až 70 mV CMC 0,0022 % 70 mV až 100 mV CMC 0,0017 % 100 mV až 150 mV CMC 0,0015 % 150 mV až 300 mV CMC 0,0013 % 300 mV až 400 mV CMC 0,0011 % 400 mV až 500 mV CMC 0,00097 % 500 mV až 1 V CMC 0,00092 % 1 V až 1,5 V CMC 0,00082 % 1,5 V až 2,2 V CMC 0,00079 % 2,2 V až 3 V CMC 0,00087 % 3 V až 4,5 V CMC 0,00083 % 4,5 V až 9 V CMC 0,00079 % 9 V až 11 V CMC 0,00075 % 11 V až 22 V CMC 0,00077 % 22 V až 45 V CMC 0,0012 % 45 V až 60 V CMC 0,0010 % 60 V až 100 V CMC 0,00095 % 100 V až 150 V CMC 0,00090 % 150 V až 220 V CMC 0,00087 % 220 V až 350 V CMC 0,0012 % 350 V až 1100 V CMC 0,0011 % TP1, TP21 Napiecie stale / Mierniki napiecia stalego, czesci elektryczne pH-metrow Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 mV do 20 mV CMC 0,8 µV od 20 mV do 25 mV CMC 0,0039 % od 25 mV do 30 mV CMC 0,0033 % od 30 mV do 35 mV CMC 0,0029 % od 35 mV do 45 mV CMC 0,0026 % od 45 mV do 70 mV CMC 0,0022 % od 70 mV do 100 mV CMC 0,0017 % od 100 mV do 150 mV CMC 0,0015 % od 150 mV do 300 mV CMC 0,0013 % od 300 mV do 400 mV CMC 0,0011 % od 400 mV do 500 mV CMC 0,00097 % od 500 mV do 1 V CMC 0,00092 % od 1 V do 1,5 V CMC 0,00082 % od 1,5 V do 2,2 V CMC 0,00079 % od 2,2 V do 3 V CMC 0,00087 % od 3 V do 4,5 V CMC 0,00083 % od 4,5 V do 9 V CMC 0,00079 % od 9 V do 11 V CMC 0,00075 % od 11 V do 22 V CMC 0,00077 % od 22 V do 45 V CMC 0,0012 % od 45 V do 60 V CMC 0,0010 % od 60 V do 100 V CMC 0,00095 % od 100 V do 150 V CMC 0,00090 % od 150 V do 220 V CMC 0,00087 % od 220 V do 350 V CMC 0,0012 % od 350 V do 1100 V CMC 0,0011 % Stejnosmerne napeti / Meridla stejnosmerneho napeti, elektricke casti pH metru Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 mV az 20 mV CMC 0,8 µV 20 mV az 25 mV CMC 0,0039 % 25 mV az 30 mV CMC 0,0033 % 30 mV az 35 mV CMC 0,0029 % 35 mV az 45 mV CMC 0,0026 % 45 mV az 70 mV CMC 0,0022 % 70 mV az 100 mV CMC 0,0017 % 100 mV az 150 mV CMC 0,0015 % 150 mV az 300 mV CMC 0,0013 % 300 mV az 400 mV CMC 0,0011 % 400 mV az 500 mV CMC 0,00097 % 500 mV az 1 V CMC 0,00092 % 1 V az 1,5 V CMC 0,00082 % 1,5 V az 2,2 V CMC 0,00079 % 2,2 V az 3 V CMC 0,00087 % 3 V az 4,5 V CMC 0,00083 % 4,5 V az 9 V CMC 0,00079 % 9 V az 11 V CMC 0,00075 % 11 V az 22 V CMC 0,00077 % 22 V az 45 V CMC 0,0012 % 45 V az 60 V CMC 0,0010 % 60 V az 100 V CMC 0,00095 % 100 V az 150 V CMC 0,00090 % 150 V az 220 V CMC 0,00087 % 220 V az 350 V CMC 0,0012 % 350 V az 1100 V CMC 0,0011 % TP1, TP21","search_en":"DC voltage / DC voltage meters, electrical parts of pH meters Calibration – electrical quantities Direct generation with a calibrator 0 mV to 20 mV CMC 0,8 µV 20 mV to 25 mV CMC 0,0039 % 25 mV to 30 mV CMC 0,0033 % 30 mV to 35 mV CMC 0,0029 % 35 mV to 45 mV CMC 0,0026 % 45 mV to 70 mV CMC 0,0022 % 70 mV to 100 mV CMC 0,0017 % 100 mV to 150 mV CMC 0,0015 % 150 mV to 300 mV CMC 0,0013 % 300 mV to 400 mV CMC 0,0011 % 400 mV to 500 mV CMC 0,00097 % 500 mV to 1 V CMC 0,00092 % 1 V to 1,5 V CMC 0,00082 % 1,5 V to 2,2 V CMC 0,00079 % 2,2 V to 3 V CMC 0,00087 % 3 V to 4,5 V CMC 0,00083 % 4,5 V to 9 V CMC 0,00079 % 9 V to 11 V CMC 0,00075 % 11 V to 22 V CMC 0,00077 % 22 V to 45 V CMC 0,0012 % 45 V to 60 V CMC 0,0010 % 60 V to 100 V CMC 0,00095 % 100 V to 150 V CMC 0,00090 % 150 V to 220 V CMC 0,00087 % 220 V to 350 V CMC 0,0012 % 350 V to 1100 V CMC 0,0011 % TP1, TP21","search_zh":"直流电压 / 直流电压测量仪器、pH 计电气部分 校准 – 电学量 用校准器直接产生 0 mV 至 20 mV CMC 0,8 µV 20 mV 至 25 mV CMC 0,0039 % 25 mV 至 30 mV CMC 0,0033 % 30 mV 至 35 mV CMC 0,0029 % 35 mV 至 45 mV CMC 0,0026 % 45 mV 至 70 mV CMC 0,0022 % 70 mV 至 100 mV CMC 0,0017 % 100 mV 至 150 mV CMC 0,0015 % 150 mV 至 300 mV CMC 0,0013 % 300 mV 至 400 mV CMC 0,0011 % 400 mV 至 500 mV CMC 0,00097 % 500 mV 至 1 V CMC 0,00092 % 1 V 至 1,5 V CMC 0,00082 % 1,5 V 至 2,2 V CMC 0,00079 % 2,2 V 至 3 V CMC 0,00087 % 3 V 至 4,5 V CMC 0,00083 % 4,5 V 至 9 V CMC 0,00079 % 9 V 至 11 V CMC 0,00075 % 11 V 至 22 V CMC 0,00077 % 22 V 至 45 V CMC 0,0012 % 45 V 至 60 V CMC 0,0010 % 60 V 至 100 V CMC 0,00095 % 100 V 至 150 V CMC 0,00090 % 150 V 至 220 V CMC 0,00087 % 220 V 至 350 V CMC 0,0012 % 350 V 至 1100 V CMC 0,0011 % TP1, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d8c05dfee24581edec5d41ad","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / Źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage sources","test_object_zh":"交流电压 / 交流电压源","test_object_cs":"Střídavé napětí / Zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 40 Hz","range":"od 1,2 mV do 2 mV","cmc":"4,4 µV"},{"name":"40 Hz do 1 kHz","range":"od 1,2 mV do 2 mV","cmc":"2,1 µV"},{"name":"1 kHz do 20 kHz","range":"od 1,2 mV do 2 mV","cmc":"2,3 µV"},{"name":"20 kHz do 50 kHz","range":"od 1,2 mV do 2 mV","cmc":"3,8 µV"},{"name":"50 kHz do 100 kHz","range":"od 1,2 mV do 2 mV","cmc":"13 µV"},{"name":"10 Hz do 100 Hz","range":"od 2 mV do 4 mV","cmc":"4,6 µV"},{"name":"100 Hz do 2 kHz","range":"od 2 mV do 4 mV","cmc":"2,5 µV"},{"name":"2 kHz do 10 kHz","range":"od 2 mV do 4 mV","cmc":"4,5 µV"},{"name":"10 kHz do 50 kHz","range":"od 2 mV do 4 mV","cmc":"6,3 µV"},{"name":"30 kHz do 100 kHz","range":"od 2 mV do 4 mV","cmc":"23 µV"},{"name":"10 Hz do 40 Hz","range":"od 4 mV do 10 mV","cmc":"5,4 µV"},{"name":"40 Hz do 100 Hz","range":"od 4 mV do 10 mV","cmc":"5,2 µV"},{"name":"100 Hz do 2 kHz","range":"od 4 mV do 10 mV","cmc":"3,1 µV"},{"name":"2 kHz do 10 kHz","range":"od 4 mV do 10 mV","cmc":"5,1 µV"},{"name":"10 kHz do 30 kHz","range":"od 4 mV do 10 mV","cmc":"12 µV"},{"name":"30 kHz do 100 kHz","range":"od 4 mV do 10 mV","cmc":"28 µV"},{"name":"50 kHz do 100 kHz","range":"od 4 mV do 10 mV","cmc":"35 µV"},{"name":"10 Hz do 40 Hz","range":"od 10 mV do 15 mV","cmc":"6,0 µV"},{"name":"40 Hz do 100 Hz","range":"od 10 mV do 15 mV","cmc":"5,7 µV"},{"name":"100 Hz do 2 kHz","range":"od 10 mV do 15 mV","cmc":"3,6 µV"},{"name":"2 kHz do 10 kHz","range":"od 10 mV do 15 mV","cmc":"5,6 µV"},{"name":"10 kHz do 30 kHz","range":"od 10 mV do 15 mV","cmc":"13 µV"},{"name":"30 kHz do 100 kHz","range":"od 10 mV do 15 mV","cmc":"31 µV"},{"name":"10 Hz do 40 Hz","range":"od 15 mV do 20 mV","cmc":"6,7 µV"},{"name":"40 Hz do 100 Hz","range":"od 15 mV do 20 mV","cmc":"6,3 µV"},{"name":"100 Hz do 2 kHz","range":"od 15 mV do 20 mV","cmc":"4,2 µV"},{"name":"2 kHz do 10 kHz","range":"od 15 mV do 20 mV","cmc":"6,2 µV"},{"name":"10 kHz do 30 kHz","range":"od 15 mV do 20 mV","cmc":"11 µV"},{"name":"30 kHz do 100 kHz","range":"od 15 mV do 20 mV","cmc":"23 µV"},{"name":"100 kHz do 300 kHz","range":"od 15 mV do 20 mV","cmc":"82 µV"},{"name":"300 kHz do 1 MHz","range":"od 15 mV do 20 mV","cmc":"0,19 mV"},{"name":"10 Hz do 40 Hz","range":"od 20 mV do 30 mV","cmc":"0,034 %"},{"name":"40 Hz do 100 Hz","range":"od 20 mV do 30 mV","cmc":"0,032 %"},{"name":"100 Hz do 2 kHz","range":"od 20 mV do 30 mV","cmc":"0,021 %"},{"name":"2 kHz do 10 kHz","range":"od 20 mV do 30 mV","cmc":"0,031 %"},{"name":"10 kHz do 30 kHz","range":"od 20 mV do 30 mV","cmc":"0,053 %"},{"name":"30 kHz do 100 kHz","range":"od 20 mV do 30 mV","cmc":"0,12 %"},{"name":"100 kHz do 300 kHz","range":"od 20 mV do 30 mV","cmc":"0,41 %"},{"name":"300 kHz do 1 MHz","range":"od 20 mV do 30 mV","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 30 mV do 50 mV","cmc":"0,027 %"},{"name":"40 Hz do 100 Hz","range":"od 30 mV do 50 mV","cmc":"0,025 %"},{"name":"100 Hz do 2 kHz","range":"od 30 mV do 50 mV","cmc":"0,018 %"},{"name":"2 kHz do 10 kHz","range":"od 30 mV do 50 mV","cmc":"0,024 %"},{"name":"10 kHz do 30 kHz","range":"od 30 mV do 50 mV","cmc":"0,047 %"},{"name":"30 kHz do 100 kHz","range":"od 30 mV do 50 mV","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 30 mV do 50 mV","cmc":"0,39 %"},{"name":"300 kHz do 1 MHz","range":"od 30 mV do 50 mV","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 50 mV do 100 mV","cmc":"0,022 %"},{"name":"40 Hz do 100 Hz","range":"od 50 mV do 100 mV","cmc":"0,020 %"},{"name":"100 Hz do 2 kHz","range":"od 50 mV do 100 mV","cmc":"0,015 %"},{"name":"2 kHz do 10 kHz","range":"od 50 mV do 100 mV","cmc":"0,019 %"},{"name":"10 kHz do 30 kHz","range":"od 50 mV do 100 mV","cmc":"0,044 %"},{"name":"30 kHz do 100 kHz","range":"od 50 mV do 100 mV","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 50 mV do 100 mV","cmc":"0,38 %"},{"name":"300 kHz do 1 MHz","range":"od 50 mV do 100 mV","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 100 mV do 150 mV","cmc":"0,018 %"},{"name":"40 Hz do 100 Hz","range":"od 100 mV do 150 mV","cmc":"0,016 %"},{"name":"100 Hz do 2 kHz","range":"od 100 mV do 150 mV","cmc":"0,013 %"},{"name":"2 kHz do 10 kHz","range":"od 100 mV do 150 mV","cmc":"0,015 %"},{"name":"10 kHz do 30 kHz","range":"od 100 mV do 150 mV","cmc":"0,039 %"},{"name":"30 kHz do 100 kHz","range":"od 100 mV do 150 mV","cmc":"0,091 %"},{"name":"100 kHz do 300 kHz","range":"od 100 mV do 150 mV","cmc":"0,45 %"},{"name":"300 kHz do 1 MHz","range":"od 100 mV do 150 mV","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 150 mV do 200 mV","cmc":"0,016 %"},{"name":"40 Hz do 100 Hz","range":"od 150 mV do 200 mV","cmc":"0,014 %"},{"name":"100 Hz do 2 kHz","range":"od 150 mV do 200 mV","cmc":"0,012 %"},{"name":"2 kHz do 10 kHz","range":"od 150 mV do 200 mV","cmc":"0,014 %"},{"name":"10 kHz do 30 kHz","range":"od 150 mV do 200 mV","cmc":"0,036 %"},{"name":"30 kHz do 100 kHz","range":"od 150 mV do 200 mV","cmc":"0,084 %"},{"name":"100 kHz do 300 kHz","range":"od 150 mV do 200 mV","cmc":"0,43 %"},{"name":"300 kHz do 1 MHz","range":"od 150 mV do 200 mV","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 200 mV do 300 mV","cmc":"0,021 %"},{"name":"40 Hz do 100 Hz","range":"od 200 mV do 300 mV","cmc":"0,019 %"},{"name":"100 Hz do 2 kHz","range":"od 200 mV do 300 mV","cmc":"0,017 %"},{"name":"2 kHz do 10 kHz","range":"od 200 mV do 300 mV","cmc":"0,019 %"},{"name":"10 kHz do 30 kHz","range":"od 200 mV do 300 mV","cmc":"0,041 %"},{"name":"30 kHz do 100 kHz","range":"od 200 mV do 300 mV","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 200 mV do 300 mV","cmc":"0,41 %"},{"name":"300 kHz do 1 MHz","range":"od 200 mV do 300 mV","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 300 mV do 500 mV","cmc":"0,018 %"},{"name":"40 Hz do 100 Hz","range":"od 300 mV do 500 mV","cmc":"0,016 %"},{"name":"100 Hz do 2 kHz","range":"od 300 mV do 500 mV","cmc":"0,014 %"},{"name":"2 kHz do 10 kHz","range":"od 300 mV do 500 mV","cmc":"0,016 %"},{"name":"10 kHz do 30 kHz","range":"od 300 mV do 500 mV","cmc":"0,034 %"},{"name":"30 kHz do 100 kHz","range":"od 300 mV do 500 mV","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 300 mV do 500 mV","cmc":"0,39 %"},{"name":"300 kHz do 1 MHz","range":"od 300 mV do 500 mV","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 500 mV do 1 V","cmc":"0,015 %"},{"name":"40 Hz do 100 Hz","range":"od 500 mV do 1 V","cmc":"0,013 %"},{"name":"100 Hz do 2 kHz","range":"od 500 mV do 1 V","cmc":"0,011 %"},{"name":"2 kHz do 10 kHz","range":"od 500 mV do 1 V","cmc":"0,013 %"},{"name":"10 kHz do 30 kHz","range":"od 500 mV do 1 V","cmc":"0,029 %"},{"name":"30 kHz do 100 kHz","range":"od 500 mV do 1 V","cmc":"0,091 %"},{"name":"100 kHz do 300 kHz","range":"od 500 mV do 1 V","cmc":"0,38 %"},{"name":"300 kHz do 1 MHz","range":"od 500 mV do 1 V","cmc":"1,2 %"},{"name":"10 Hz do 40 Hz","range":"od 1 V do 1,5 V","cmc":"0,013 %"},{"name":"40 Hz do 100 Hz","range":"od 1 V do 1,5 V","cmc":"0,011 %"},{"name":"100 Hz do 2 kHz","range":"od 1 V do 1,5 V","cmc":"0,0086 %"},{"name":"2 kHz do 10 kHz","range":"od 1 V do 1,5 V","cmc":"0,011 %"},{"name":"10 kHz do 30 kHz","range":"od 1 V do 1,5 V","cmc":"0,025 %"},{"name":"30 kHz do 100 kHz","range":"od 1 V do 1,5 V","cmc":"0,071 %"},{"name":"100 kHz do 300 kHz","range":"od 1 V do 1,5 V","cmc":"0,45 %"},{"name":"300 kHz do 1 MHz","range":"od 1 V do 1,5 V","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 1,5 V do 2 V","cmc":"0,012 %"},{"name":"40 Hz do 100 Hz","range":"od 1,5 V do 2 V","cmc":"0,0099 %"},{"name":"100 Hz do 2 kHz","range":"od 1,5 V do 2 V","cmc":"0,0079 %"},{"name":"2 kHz do 10 kHz","range":"od 1,5 V do 2 V","cmc":"0,010 %"},{"name":"10 kHz do 30 kHz","range":"od 1,5 V do 2 V","cmc":"0,024 %"},{"name":"30 kHz do 100 kHz","range":"od 1,5 V do 2 V","cmc":"0,065 %"},{"name":"100 kHz do 300 kHz","range":"od 1,5 V do 2 V","cmc":"0,43 %"},{"name":"300 kHz do 1 MHz","range":"od 1,5 V do 2 V","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 2 V do 3 V","cmc":"0,021 %"},{"name":"40 Hz do 100 Hz","range":"od 2 V do 3 V","cmc":"0,019 %"},{"name":"100 Hz do 2 kHz","range":"od 2 V do 3 V","cmc":"0,017 %"},{"name":"2 kHz do 10 kHz","range":"od 2 V do 3 V","cmc":"0,019 %"},{"name":"10 kHz do 30 kHz","range":"od 2 V do 3 V","cmc":"0,041 %"},{"name":"30 kHz do 100 kHz","range":"od 2 V do 3 V","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 2 V do 3 V","cmc":"0,41 %"},{"name":"300 kHz do 1 MHz","range":"od 2 V do 3 V","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 3 V do 5 V","cmc":"0,018 %"},{"name":"40 Hz do 100 Hz","range":"od 3 V do 5 V","cmc":"0,016 %"},{"name":"100 Hz do 2 kHz","range":"od 3 V do 5 V","cmc":"0,014 %"},{"name":"2 kHz do 10 kHz","range":"od 3 V do 5 V","cmc":"0,016 %"},{"name":"10 kHz do 30 kHz","range":"od 3 V do 5 V","cmc":"0,034 %"},{"name":"30 kHz do 100 kHz","range":"od 3 V do 5 V","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 3 V do 5 V","cmc":"0,39 %"},{"name":"300 kHz do 1 MHz","range":"od 3 V do 5 V","cmc":"1,3 %"},{"name":"10 Hz do 40 Hz","range":"od 5 V do 10 V","cmc":"0,015 %"},{"name":"40 Hz do 100 Hz","range":"od 5 V do 10 V","cmc":"0,013 %"},{"name":"100 Hz do 2 kHz","range":"od 5 V do 10 V","cmc":"0,011 %"},{"name":"2 kHz do 10 kHz","range":"od 5 V do 10 V","cmc":"0,013 %"},{"name":"10 kHz do 30 kHz","range":"od 5 V do 10 V","cmc":"0,029 %"},{"name":"30 kHz do 100 kHz","range":"od 5 V do 10 V","cmc":"0,091 %"},{"name":"100 kHz do 300 kHz","range":"od 5 V do 10 V","cmc":"0,38 %"},{"name":"300 kHz do 1 MHz","range":"od 5 V do 10 V","cmc":"1,2 %"},{"name":"10 Hz do 40 Hz","range":"od 10 V do 15 V","cmc":"0,013 %"},{"name":"40 Hz do 100 Hz","range":"od 10 V do 15 V","cmc":"0,011 %"},{"name":"100 Hz do 2 kHz","range":"od 10 V do 15 V","cmc":"0,0086 %"},{"name":"2 kHz do 10 kHz","range":"od 10 V do 15 V","cmc":"0,011 %"},{"name":"10 kHz do 30 kHz","range":"od 10 V do 15 V","cmc":"0,025 %"},{"name":"30 kHz do 100 kHz","range":"od 10 V do 15 V","cmc":"0,071 %"},{"name":"100 kHz do 300 kHz","range":"od 10 V do 15 V","cmc":"0,51 %"},{"name":"300 kHz do 1 MHz","range":"od 10 V do 15 V","cmc":"3,1 %"},{"name":"10 Hz do 40 Hz","range":"od 15 V do 20 V","cmc":"0,012 %"},{"name":"40 Hz do 100 Hz","range":"od 15 V do 20 V","cmc":"0,0099 %"},{"name":"100 Hz do 2 kHz","range":"od 15 V do 20 V","cmc":"0,0079 %"},{"name":"2 kHz do 10 kHz","range":"od 15 V do 20 V","cmc":"0,010 %"},{"name":"10 kHz do 30 kHz","range":"od 15 V do 20 V","cmc":"0,024 %"},{"name":"30 kHz do 100 kHz","range":"od 15 V do 20 V","cmc":"0,065 %"},{"name":"100 kHz do 300 kHz","range":"od 15 V do 20 V","cmc":"0,44 %"},{"name":"300 kHz do 1 MHz","range":"od 15 V do 20 V","cmc":"2,4 %"},{"name":"10 Hz do 40 Hz","range":"od 20 V do 30 V","cmc":"0,021 %"},{"name":"40 Hz do 100 Hz","range":"od 20 V do 30 V","cmc":"0,019 %"},{"name":"100 Hz do 2 kHz","range":"od 20 V do 30 V","cmc":"0,017 %"},{"name":"2 kHz do 10 kHz","range":"od 20 V do 30 V","cmc":"0,019 %"},{"name":"10 kHz do 30 kHz","range":"od 20 V do 30 V","cmc":"0,041 %"},{"name":"30 kHz do 100 kHz","range":"od 20 V do 30 V","cmc":"0,16 %"},{"name":"10 Hz do 40 Hz","range":"od 30 V do 50 V","cmc":"0,018 %"},{"name":"40 Hz do 100 Hz","range":"od 30 V do 50 V","cmc":"0,016 %"},{"name":"100 Hz do 2 kHz","range":"od 30 V do 50 V","cmc":"0,014 %"},{"name":"2 kHz do 10 kHz","range":"od 30 V do 50 V","cmc":"0,016 %"},{"name":"10 kHz do 30 kHz","range":"od 30 V do 50 V","cmc":"0,034 %"},{"name":"30 kHz do 100 kHz","range":"od 30 V do 50 V","cmc":"0,12 %"},{"name":"10 Hz do 40 Hz","range":"od 50 V do 100 V","cmc":"0,015 %"},{"name":"40 Hz do 100 Hz","range":"od 50 V do 100 V","cmc":"0,013 %"},{"name":"100 Hz do 2 kHz","range":"od 50 V do 100 V","cmc":"0,011 %"},{"name":"2 kHz do 10 kHz","range":"od 50 V do 100 V","cmc":"0,013 %"},{"name":"10 kHz do 30 kHz","range":"od 50 V do 100 V","cmc":"0,029 %"},{"name":"30 kHz do 100 kHz","range":"od 50 V do 100 V","cmc":"0,091 %"},{"name":"10 Hz do 40 Hz","range":"od 100 V do 150 V","cmc":"0,013 %"},{"name":"40 Hz do 100 Hz","range":"od 100 V do 150 V","cmc":"0,011 %"},{"name":"100 Hz do 2 kHz","range":"od 100 V do 150 V","cmc":"0,0086 %"},{"name":"2 kHz do 10 kHz","range":"od 100 V do 150 V","cmc":"0,011 %"},{"name":"10 kHz do 30 kHz","range":"od 100 V do 150 V","cmc":"0,025 %"},{"name":"30 kHz do 100 kHz","range":"od 100 V do 150 V","cmc":"0,071 %"},{"name":"10 Hz do 40 Hz","range":"od 150 V do 200 V","cmc":"0,012 %"},{"name":"40 Hz do 100 Hz","range":"od 150 V do 200 V","cmc":"0,0099 %"},{"name":"100 Hz do 2 kHz","range":"od 150 V do 200 V","cmc":"0,0079 %"},{"name":"2 kHz do 10 kHz","range":"od 150 V do 200 V","cmc":"0,010 %"},{"name":"10 kHz do 30 kHz","range":"od 150 V do 200 V","cmc":"0,024 %"},{"name":"30 kHz do 100 kHz","range":"od 150 V do 200 V","cmc":"0,065 %"},{"name":"40 Hz do 10 kHz","range":"od 200 V do 300 V","cmc":"0,020 %"},{"name":"10 kHz do 30 kHz","range":"od 200 V do 300 V","cmc":"0,041 %"},{"name":"30 kHz do 100 kHz","range":"od 200 V do 300 V","cmc":"0,11 %"},{"name":"40 Hz do 10 kHz","range":"od 300 V do 400 V","cmc":"0,017 %"},{"name":"10 kHz do 30 kHz","range":"od 300 V do 400 V","cmc":"0,034 %"},{"name":"30 kHz do 100 kHz","range":"od 300 V do 400 V","cmc":"0,077 %"},{"name":"40 Hz do 10 kHz","range":"od 400 V do 500 V","cmc":"0,016 %"},{"name":"10 kHz do 20 kHz","range":"od 400 V do 500 V","cmc":"0,035 %"},{"name":"20 kHz do 30 kHz","range":"od 400 V do 500 V","cmc":"0,039 %"},{"name":"30 kHz do 100 kHz","range":"od 400 V do 500 V","cmc":"0,063 %"},{"name":"40 Hz do 10 kHz","range":"od 500 V do 600 V","cmc":"0,017 %"},{"name":"10 kHz do 20 kHz","range":"od 500 V do 600 V","cmc":"0,040 %"},{"name":"20 kHz do 30 kHz","range":"od 500 V do 600 V","cmc":"0,049 %"},{"name":"30 kHz do 100 kHz","range":"od 500 V do 600 V","cmc":"0,065 %"},{"name":"40 Hz do 10 kHz","range":"od 600 V do 700 V","cmc":"0,019 %"},{"name":"10 kHz do 20 kHz","range":"od 600 V do 700 V","cmc":"0,049 %"},{"name":"20 kHz do 30 kHz","range":"od 600 V do 700 V","cmc":"0,065 %"},{"name":"30 kHz do 100 kHz","range":"od 600 V do 700 V","cmc":"0,077 %"},{"name":"40 Hz do 10 kHz","range":"od 700 V do 800 V","cmc":"0,023 %"},{"name":"10 kHz do 20 kHz","range":"od 700 V do 800 V","cmc":"0,061 %"},{"name":"20 kHz do 30 kHz","range":"od 700 V do 800 V","cmc":"0,086 %"},{"name":"30 kHz do 100 kHz","range":"od 700 V do 800 V","cmc":"0,095 %"},{"name":"40 Hz do 10 kHz","range":"od 800 V do 900 V","cmc":"0,027 %"},{"name":"10 kHz do 20 kHz","range":"od 800 V do 900 V","cmc":"0,076 %"},{"name":"20 kHz do 100 kHz","range":"od 800 V do 900 V","cmc":"0,12 %"},{"name":"40 Hz do 10 kHz","range":"od 900 V do 1000 V","cmc":"0,032 %"},{"name":"10 kHz do 20 kHz","range":"od 900 V do 1000 V","cmc":"0,094 %"},{"name":"20 kHz do 100 kHz","range":"od 900 V do 1000 V","cmc":"0,15 %"},{"name":"40 Hz do 10 kHz","range":"od 1000 V do 1050 V","cmc":"0,034 %"},{"name":"10 kHz do 20 kHz","range":"od 1000 V do 1050 V","cmc":"0,11 %"},{"name":"20 kHz do 100 kHz","range":"od 1000 V do 1050 V","cmc":"0,16 %"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"1,2 mV to 2 mV","cmc":"4,4 µV"},{"name":"40 Hz to 1 kHz","range":"1,2 mV to 2 mV","cmc":"2,1 µV"},{"name":"1 kHz to 20 kHz","range":"1,2 mV to 2 mV","cmc":"2,3 µV"},{"name":"20 kHz to 50 kHz","range":"1,2 mV to 2 mV","cmc":"3,8 µV"},{"name":"50 kHz to 100 kHz","range":"1,2 mV to 2 mV","cmc":"13 µV"},{"name":"10 Hz to 100 Hz","range":"2 mV to 4 mV","cmc":"4,6 µV"},{"name":"100 Hz to 2 kHz","range":"2 mV to 4 mV","cmc":"2,5 µV"},{"name":"2 kHz to 10 kHz","range":"2 mV to 4 mV","cmc":"4,5 µV"},{"name":"10 kHz to 50 kHz","range":"2 mV to 4 mV","cmc":"6,3 µV"},{"name":"30 kHz to 100 kHz","range":"2 mV to 4 mV","cmc":"23 µV"},{"name":"10 Hz to 40 Hz","range":"4 mV to 10 mV","cmc":"5,4 µV"},{"name":"40 Hz to 100 Hz","range":"4 mV to 10 mV","cmc":"5,2 µV"},{"name":"100 Hz to 2 kHz","range":"4 mV to 10 mV","cmc":"3,1 µV"},{"name":"2 kHz to 10 kHz","range":"4 mV to 10 mV","cmc":"5,1 µV"},{"name":"10 kHz to 30 kHz","range":"4 mV to 10 mV","cmc":"12 µV"},{"name":"30 kHz to 100 kHz","range":"4 mV to 10 mV","cmc":"28 µV"},{"name":"50 kHz to 100 kHz","range":"4 mV to 10 mV","cmc":"35 µV"},{"name":"10 Hz to 40 Hz","range":"10 mV to 15 mV","cmc":"6,0 µV"},{"name":"40 Hz to 100 Hz","range":"10 mV to 15 mV","cmc":"5,7 µV"},{"name":"100 Hz to 2 kHz","range":"10 mV to 15 mV","cmc":"3,6 µV"},{"name":"2 kHz to 10 kHz","range":"10 mV to 15 mV","cmc":"5,6 µV"},{"name":"10 kHz to 30 kHz","range":"10 mV to 15 mV","cmc":"13 µV"},{"name":"30 kHz to 100 kHz","range":"10 mV to 15 mV","cmc":"31 µV"},{"name":"10 Hz to 40 Hz","range":"15 mV to 20 mV","cmc":"6,7 µV"},{"name":"40 Hz to 100 Hz","range":"15 mV to 20 mV","cmc":"6,3 µV"},{"name":"100 Hz to 2 kHz","range":"15 mV to 20 mV","cmc":"4,2 µV"},{"name":"2 kHz to 10 kHz","range":"15 mV to 20 mV","cmc":"6,2 µV"},{"name":"10 kHz to 30 kHz","range":"15 mV to 20 mV","cmc":"11 µV"},{"name":"30 kHz to 100 kHz","range":"15 mV to 20 mV","cmc":"23 µV"},{"name":"100 kHz to 300 kHz","range":"15 mV to 20 mV","cmc":"82 µV"},{"name":"300 kHz to 1 MHz","range":"15 mV to 20 mV","cmc":"0,19 mV"},{"name":"10 Hz to 40 Hz","range":"20 mV to 30 mV","cmc":"0,034 %"},{"name":"40 Hz to 100 Hz","range":"20 mV to 30 mV","cmc":"0,032 %"},{"name":"100 Hz to 2 kHz","range":"20 mV to 30 mV","cmc":"0,021 %"},{"name":"2 kHz to 10 kHz","range":"20 mV to 30 mV","cmc":"0,031 %"},{"name":"10 kHz to 30 kHz","range":"20 mV to 30 mV","cmc":"0,053 %"},{"name":"30 kHz to 100 kHz","range":"20 mV to 30 mV","cmc":"0,12 %"},{"name":"100 kHz to 300 kHz","range":"20 mV to 30 mV","cmc":"0,41 %"},{"name":"300 kHz to 1 MHz","range":"20 mV to 30 mV","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"30 mV to 50 mV","cmc":"0,027 %"},{"name":"40 Hz to 100 Hz","range":"30 mV to 50 mV","cmc":"0,025 %"},{"name":"100 Hz to 2 kHz","range":"30 mV to 50 mV","cmc":"0,018 %"},{"name":"2 kHz to 10 kHz","range":"30 mV to 50 mV","cmc":"0,024 %"},{"name":"10 kHz to 30 kHz","range":"30 mV to 50 mV","cmc":"0,047 %"},{"name":"30 kHz to 100 kHz","range":"30 mV to 50 mV","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"30 mV to 50 mV","cmc":"0,39 %"},{"name":"300 kHz to 1 MHz","range":"30 mV to 50 mV","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"50 mV to 100 mV","cmc":"0,022 %"},{"name":"40 Hz to 100 Hz","range":"50 mV to 100 mV","cmc":"0,020 %"},{"name":"100 Hz to 2 kHz","range":"50 mV to 100 mV","cmc":"0,015 %"},{"name":"2 kHz to 10 kHz","range":"50 mV to 100 mV","cmc":"0,019 %"},{"name":"10 kHz to 30 kHz","range":"50 mV to 100 mV","cmc":"0,044 %"},{"name":"30 kHz to 100 kHz","range":"50 mV to 100 mV","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"50 mV to 100 mV","cmc":"0,38 %"},{"name":"300 kHz to 1 MHz","range":"50 mV to 100 mV","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"100 mV to 150 mV","cmc":"0,018 %"},{"name":"40 Hz to 100 Hz","range":"100 mV to 150 mV","cmc":"0,016 %"},{"name":"100 Hz to 2 kHz","range":"100 mV to 150 mV","cmc":"0,013 %"},{"name":"2 kHz to 10 kHz","range":"100 mV to 150 mV","cmc":"0,015 %"},{"name":"10 kHz to 30 kHz","range":"100 mV to 150 mV","cmc":"0,039 %"},{"name":"30 kHz to 100 kHz","range":"100 mV to 150 mV","cmc":"0,091 %"},{"name":"100 kHz to 300 kHz","range":"100 mV to 150 mV","cmc":"0,45 %"},{"name":"300 kHz to 1 MHz","range":"100 mV to 150 mV","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"150 mV to 200 mV","cmc":"0,016 %"},{"name":"40 Hz to 100 Hz","range":"150 mV to 200 mV","cmc":"0,014 %"},{"name":"100 Hz to 2 kHz","range":"150 mV to 200 mV","cmc":"0,012 %"},{"name":"2 kHz to 10 kHz","range":"150 mV to 200 mV","cmc":"0,014 %"},{"name":"10 kHz to 30 kHz","range":"150 mV to 200 mV","cmc":"0,036 %"},{"name":"30 kHz to 100 kHz","range":"150 mV to 200 mV","cmc":"0,084 %"},{"name":"100 kHz to 300 kHz","range":"150 mV to 200 mV","cmc":"0,43 %"},{"name":"300 kHz to 1 MHz","range":"150 mV to 200 mV","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"200 mV to 300 mV","cmc":"0,021 %"},{"name":"40 Hz to 100 Hz","range":"200 mV to 300 mV","cmc":"0,019 %"},{"name":"100 Hz to 2 kHz","range":"200 mV to 300 mV","cmc":"0,017 %"},{"name":"2 kHz to 10 kHz","range":"200 mV to 300 mV","cmc":"0,019 %"},{"name":"10 kHz to 30 kHz","range":"200 mV to 300 mV","cmc":"0,041 %"},{"name":"30 kHz to 100 kHz","range":"200 mV to 300 mV","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"200 mV to 300 mV","cmc":"0,41 %"},{"name":"300 kHz to 1 MHz","range":"200 mV to 300 mV","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"300 mV to 500 mV","cmc":"0,018 %"},{"name":"40 Hz to 100 Hz","range":"300 mV to 500 mV","cmc":"0,016 %"},{"name":"100 Hz to 2 kHz","range":"300 mV to 500 mV","cmc":"0,014 %"},{"name":"2 kHz to 10 kHz","range":"300 mV to 500 mV","cmc":"0,016 %"},{"name":"10 kHz to 30 kHz","range":"300 mV to 500 mV","cmc":"0,034 %"},{"name":"30 kHz to 100 kHz","range":"300 mV to 500 mV","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"300 mV to 500 mV","cmc":"0,39 %"},{"name":"300 kHz to 1 MHz","range":"300 mV to 500 mV","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"500 mV to 1 V","cmc":"0,015 %"},{"name":"40 Hz to 100 Hz","range":"500 mV to 1 V","cmc":"0,013 %"},{"name":"100 Hz to 2 kHz","range":"500 mV to 1 V","cmc":"0,011 %"},{"name":"2 kHz to 10 kHz","range":"500 mV to 1 V","cmc":"0,013 %"},{"name":"10 kHz to 30 kHz","range":"500 mV to 1 V","cmc":"0,029 %"},{"name":"30 kHz to 100 kHz","range":"500 mV to 1 V","cmc":"0,091 %"},{"name":"100 kHz to 300 kHz","range":"500 mV to 1 V","cmc":"0,38 %"},{"name":"300 kHz to 1 MHz","range":"500 mV to 1 V","cmc":"1,2 %"},{"name":"10 Hz to 40 Hz","range":"1 V to 1,5 V","cmc":"0,013 %"},{"name":"40 Hz to 100 Hz","range":"1 V to 1,5 V","cmc":"0,011 %"},{"name":"100 Hz to 2 kHz","range":"1 V to 1,5 V","cmc":"0,0086 %"},{"name":"2 kHz to 10 kHz","range":"1 V to 1,5 V","cmc":"0,011 %"},{"name":"10 kHz to 30 kHz","range":"1 V to 1,5 V","cmc":"0,025 %"},{"name":"30 kHz to 100 kHz","range":"1 V to 1,5 V","cmc":"0,071 %"},{"name":"100 kHz to 300 kHz","range":"1 V to 1,5 V","cmc":"0,45 %"},{"name":"300 kHz to 1 MHz","range":"1 V to 1,5 V","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"1,5 V to 2 V","cmc":"0,012 %"},{"name":"40 Hz to 100 Hz","range":"1,5 V to 2 V","cmc":"0,0099 %"},{"name":"100 Hz to 2 kHz","range":"1,5 V to 2 V","cmc":"0,0079 %"},{"name":"2 kHz to 10 kHz","range":"1,5 V to 2 V","cmc":"0,010 %"},{"name":"10 kHz to 30 kHz","range":"1,5 V to 2 V","cmc":"0,024 %"},{"name":"30 kHz to 100 kHz","range":"1,5 V to 2 V","cmc":"0,065 %"},{"name":"100 kHz to 300 kHz","range":"1,5 V to 2 V","cmc":"0,43 %"},{"name":"300 kHz to 1 MHz","range":"1,5 V to 2 V","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"2 V to 3 V","cmc":"0,021 %"},{"name":"40 Hz to 100 Hz","range":"2 V to 3 V","cmc":"0,019 %"},{"name":"100 Hz to 2 kHz","range":"2 V to 3 V","cmc":"0,017 %"},{"name":"2 kHz to 10 kHz","range":"2 V to 3 V","cmc":"0,019 %"},{"name":"10 kHz to 30 kHz","range":"2 V to 3 V","cmc":"0,041 %"},{"name":"30 kHz to 100 kHz","range":"2 V to 3 V","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"2 V to 3 V","cmc":"0,41 %"},{"name":"300 kHz to 1 MHz","range":"2 V to 3 V","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"3 V to 5 V","cmc":"0,018 %"},{"name":"40 Hz to 100 Hz","range":"3 V to 5 V","cmc":"0,016 %"},{"name":"100 Hz to 2 kHz","range":"3 V to 5 V","cmc":"0,014 %"},{"name":"2 kHz to 10 kHz","range":"3 V to 5 V","cmc":"0,016 %"},{"name":"10 kHz to 30 kHz","range":"3 V to 5 V","cmc":"0,034 %"},{"name":"30 kHz to 100 kHz","range":"3 V to 5 V","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"3 V to 5 V","cmc":"0,39 %"},{"name":"300 kHz to 1 MHz","range":"3 V to 5 V","cmc":"1,3 %"},{"name":"10 Hz to 40 Hz","range":"5 V to 10 V","cmc":"0,015 %"},{"name":"40 Hz to 100 Hz","range":"5 V to 10 V","cmc":"0,013 %"},{"name":"100 Hz to 2 kHz","range":"5 V to 10 V","cmc":"0,011 %"},{"name":"2 kHz to 10 kHz","range":"5 V to 10 V","cmc":"0,013 %"},{"name":"10 kHz to 30 kHz","range":"5 V to 10 V","cmc":"0,029 %"},{"name":"30 kHz to 100 kHz","range":"5 V to 10 V","cmc":"0,091 %"},{"name":"100 kHz to 300 kHz","range":"5 V to 10 V","cmc":"0,38 %"},{"name":"300 kHz to 1 MHz","range":"5 V to 10 V","cmc":"1,2 %"},{"name":"10 Hz to 40 Hz","range":"10 V to 15 V","cmc":"0,013 %"},{"name":"40 Hz to 100 Hz","range":"10 V to 15 V","cmc":"0,011 %"},{"name":"100 Hz to 2 kHz","range":"10 V to 15 V","cmc":"0,0086 %"},{"name":"2 kHz to 10 kHz","range":"10 V to 15 V","cmc":"0,011 %"},{"name":"10 kHz to 30 kHz","range":"10 V to 15 V","cmc":"0,025 %"},{"name":"30 kHz to 100 kHz","range":"10 V to 15 V","cmc":"0,071 %"},{"name":"100 kHz to 300 kHz","range":"10 V to 15 V","cmc":"0,51 %"},{"name":"300 kHz to 1 MHz","range":"10 V to 15 V","cmc":"3,1 %"},{"name":"10 Hz to 40 Hz","range":"15 V to 20 V","cmc":"0,012 %"},{"name":"40 Hz to 100 Hz","range":"15 V to 20 V","cmc":"0,0099 %"},{"name":"100 Hz to 2 kHz","range":"15 V to 20 V","cmc":"0,0079 %"},{"name":"2 kHz to 10 kHz","range":"15 V to 20 V","cmc":"0,010 %"},{"name":"10 kHz to 30 kHz","range":"15 V to 20 V","cmc":"0,024 %"},{"name":"30 kHz to 100 kHz","range":"15 V to 20 V","cmc":"0,065 %"},{"name":"100 kHz to 300 kHz","range":"15 V to 20 V","cmc":"0,44 %"},{"name":"300 kHz to 1 MHz","range":"15 V to 20 V","cmc":"2,4 %"},{"name":"10 Hz to 40 Hz","range":"20 V to 30 V","cmc":"0,021 %"},{"name":"40 Hz to 100 Hz","range":"20 V to 30 V","cmc":"0,019 %"},{"name":"100 Hz to 2 kHz","range":"20 V to 30 V","cmc":"0,017 %"},{"name":"2 kHz to 10 kHz","range":"20 V to 30 V","cmc":"0,019 %"},{"name":"10 kHz to 30 kHz","range":"20 V to 30 V","cmc":"0,041 %"},{"name":"30 kHz to 100 kHz","range":"20 V to 30 V","cmc":"0,16 %"},{"name":"10 Hz to 40 Hz","range":"30 V to 50 V","cmc":"0,018 %"},{"name":"40 Hz to 100 Hz","range":"30 V to 50 V","cmc":"0,016 %"},{"name":"100 Hz to 2 kHz","range":"30 V to 50 V","cmc":"0,014 %"},{"name":"2 kHz to 10 kHz","range":"30 V to 50 V","cmc":"0,016 %"},{"name":"10 kHz to 30 kHz","range":"30 V to 50 V","cmc":"0,034 %"},{"name":"30 kHz to 100 kHz","range":"30 V to 50 V","cmc":"0,12 %"},{"name":"10 Hz to 40 Hz","range":"50 V to 100 V","cmc":"0,015 %"},{"name":"40 Hz to 100 Hz","range":"50 V to 100 V","cmc":"0,013 %"},{"name":"100 Hz to 2 kHz","range":"50 V to 100 V","cmc":"0,011 %"},{"name":"2 kHz to 10 kHz","range":"50 V to 100 V","cmc":"0,013 %"},{"name":"10 kHz to 30 kHz","range":"50 V to 100 V","cmc":"0,029 %"},{"name":"30 kHz to 100 kHz","range":"50 V to 100 V","cmc":"0,091 %"},{"name":"10 Hz to 40 Hz","range":"100 V to 150 V","cmc":"0,013 %"},{"name":"40 Hz to 100 Hz","range":"100 V to 150 V","cmc":"0,011 %"},{"name":"100 Hz to 2 kHz","range":"100 V to 150 V","cmc":"0,0086 %"},{"name":"2 kHz to 10 kHz","range":"100 V to 150 V","cmc":"0,011 %"},{"name":"10 kHz to 30 kHz","range":"100 V to 150 V","cmc":"0,025 %"},{"name":"30 kHz to 100 kHz","range":"100 V to 150 V","cmc":"0,071 %"},{"name":"10 Hz to 40 Hz","range":"150 V to 200 V","cmc":"0,012 %"},{"name":"40 Hz to 100 Hz","range":"150 V to 200 V","cmc":"0,0099 %"},{"name":"100 Hz to 2 kHz","range":"150 V to 200 V","cmc":"0,0079 %"},{"name":"2 kHz to 10 kHz","range":"150 V to 200 V","cmc":"0,010 %"},{"name":"10 kHz to 30 kHz","range":"150 V to 200 V","cmc":"0,024 %"},{"name":"30 kHz to 100 kHz","range":"150 V to 200 V","cmc":"0,065 %"},{"name":"40 Hz to 10 kHz","range":"200 V to 300 V","cmc":"0,020 %"},{"name":"10 kHz to 30 kHz","range":"200 V to 300 V","cmc":"0,041 %"},{"name":"30 kHz to 100 kHz","range":"200 V to 300 V","cmc":"0,11 %"},{"name":"40 Hz to 10 kHz","range":"300 V to 400 V","cmc":"0,017 %"},{"name":"10 kHz to 30 kHz","range":"300 V to 400 V","cmc":"0,034 %"},{"name":"30 kHz to 100 kHz","range":"300 V to 400 V","cmc":"0,077 %"},{"name":"40 Hz to 10 kHz","range":"400 V to 500 V","cmc":"0,016 %"},{"name":"10 kHz to 20 kHz","range":"400 V to 500 V","cmc":"0,035 %"},{"name":"20 kHz to 30 kHz","range":"400 V to 500 V","cmc":"0,039 %"},{"name":"30 kHz to 100 kHz","range":"400 V to 500 V","cmc":"0,063 %"},{"name":"40 Hz to 10 kHz","range":"500 V to 600 V","cmc":"0,017 %"},{"name":"10 kHz to 20 kHz","range":"500 V to 600 V","cmc":"0,040 %"},{"name":"20 kHz to 30 kHz","range":"500 V to 600 V","cmc":"0,049 %"},{"name":"30 kHz to 100 kHz","range":"500 V to 600 V","cmc":"0,065 %"},{"name":"40 Hz to 10 kHz","range":"600 V to 700 V","cmc":"0,019 %"},{"name":"10 kHz to 20 kHz","range":"600 V to 700 V","cmc":"0,049 %"},{"name":"20 kHz to 30 kHz","range":"600 V to 700 V","cmc":"0,065 %"},{"name":"30 kHz to 100 kHz","range":"600 V to 700 V","cmc":"0,077 %"},{"name":"40 Hz to 10 kHz","range":"700 V to 800 V","cmc":"0,023 %"},{"name":"10 kHz to 20 kHz","range":"700 V to 800 V","cmc":"0,061 %"},{"name":"20 kHz to 30 kHz","range":"700 V to 800 V","cmc":"0,086 %"},{"name":"30 kHz to 100 kHz","range":"700 V to 800 V","cmc":"0,095 %"},{"name":"40 Hz to 10 kHz","range":"800 V to 900 V","cmc":"0,027 %"},{"name":"10 kHz to 20 kHz","range":"800 V to 900 V","cmc":"0,076 %"},{"name":"20 kHz to 100 kHz","range":"800 V to 900 V","cmc":"0,12 %"},{"name":"40 Hz to 10 kHz","range":"900 V to 1000 V","cmc":"0,032 %"},{"name":"10 kHz to 20 kHz","range":"900 V to 1000 V","cmc":"0,094 %"},{"name":"20 kHz to 100 kHz","range":"900 V to 1000 V","cmc":"0,15 %"},{"name":"40 Hz to 10 kHz","range":"1000 V to 1050 V","cmc":"0,034 %"},{"name":"10 kHz to 20 kHz","range":"1000 V to 1050 V","cmc":"0,11 %"},{"name":"20 kHz to 100 kHz","range":"1000 V to 1050 V","cmc":"0,16 %"}],"parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"1,2 mV 至 2 mV","cmc":"4,4 µV"},{"name":"40 Hz 至 1 kHz","range":"1,2 mV 至 2 mV","cmc":"2,1 µV"},{"name":"1 kHz 至 20 kHz","range":"1,2 mV 至 2 mV","cmc":"2,3 µV"},{"name":"20 kHz 至 50 kHz","range":"1,2 mV 至 2 mV","cmc":"3,8 µV"},{"name":"50 kHz 至 100 kHz","range":"1,2 mV 至 2 mV","cmc":"13 µV"},{"name":"10 Hz 至 100 Hz","range":"2 mV 至 4 mV","cmc":"4,6 µV"},{"name":"100 Hz 至 2 kHz","range":"2 mV 至 4 mV","cmc":"2,5 µV"},{"name":"2 kHz 至 10 kHz","range":"2 mV 至 4 mV","cmc":"4,5 µV"},{"name":"10 kHz 至 50 kHz","range":"2 mV 至 4 mV","cmc":"6,3 µV"},{"name":"30 kHz 至 100 kHz","range":"2 mV 至 4 mV","cmc":"23 µV"},{"name":"10 Hz 至 40 Hz","range":"4 mV 至 10 mV","cmc":"5,4 µV"},{"name":"40 Hz 至 100 Hz","range":"4 mV 至 10 mV","cmc":"5,2 µV"},{"name":"100 Hz 至 2 kHz","range":"4 mV 至 10 mV","cmc":"3,1 µV"},{"name":"2 kHz 至 10 kHz","range":"4 mV 至 10 mV","cmc":"5,1 µV"},{"name":"10 kHz 至 30 kHz","range":"4 mV 至 10 mV","cmc":"12 µV"},{"name":"30 kHz 至 100 kHz","range":"4 mV 至 10 mV","cmc":"28 µV"},{"name":"50 kHz 至 100 kHz","range":"4 mV 至 10 mV","cmc":"35 µV"},{"name":"10 Hz 至 40 Hz","range":"10 mV 至 15 mV","cmc":"6,0 µV"},{"name":"40 Hz 至 100 Hz","range":"10 mV 至 15 mV","cmc":"5,7 µV"},{"name":"100 Hz 至 2 kHz","range":"10 mV 至 15 mV","cmc":"3,6 µV"},{"name":"2 kHz 至 10 kHz","range":"10 mV 至 15 mV","cmc":"5,6 µV"},{"name":"10 kHz 至 30 kHz","range":"10 mV 至 15 mV","cmc":"13 µV"},{"name":"30 kHz 至 100 kHz","range":"10 mV 至 15 mV","cmc":"31 µV"},{"name":"10 Hz 至 40 Hz","range":"15 mV 至 20 mV","cmc":"6,7 µV"},{"name":"40 Hz 至 100 Hz","range":"15 mV 至 20 mV","cmc":"6,3 µV"},{"name":"100 Hz 至 2 kHz","range":"15 mV 至 20 mV","cmc":"4,2 µV"},{"name":"2 kHz 至 10 kHz","range":"15 mV 至 20 mV","cmc":"6,2 µV"},{"name":"10 kHz 至 30 kHz","range":"15 mV 至 20 mV","cmc":"11 µV"},{"name":"30 kHz 至 100 kHz","range":"15 mV 至 20 mV","cmc":"23 µV"},{"name":"100 kHz 至 300 kHz","range":"15 mV 至 20 mV","cmc":"82 µV"},{"name":"300 kHz 至 1 MHz","range":"15 mV 至 20 mV","cmc":"0,19 mV"},{"name":"10 Hz 至 40 Hz","range":"20 mV 至 30 mV","cmc":"0,034 %"},{"name":"40 Hz 至 100 Hz","range":"20 mV 至 30 mV","cmc":"0,032 %"},{"name":"100 Hz 至 2 kHz","range":"20 mV 至 30 mV","cmc":"0,021 %"},{"name":"2 kHz 至 10 kHz","range":"20 mV 至 30 mV","cmc":"0,031 %"},{"name":"10 kHz 至 30 kHz","range":"20 mV 至 30 mV","cmc":"0,053 %"},{"name":"30 kHz 至 100 kHz","range":"20 mV 至 30 mV","cmc":"0,12 %"},{"name":"100 kHz 至 300 kHz","range":"20 mV 至 30 mV","cmc":"0,41 %"},{"name":"300 kHz 至 1 MHz","range":"20 mV 至 30 mV","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"30 mV 至 50 mV","cmc":"0,027 %"},{"name":"40 Hz 至 100 Hz","range":"30 mV 至 50 mV","cmc":"0,025 %"},{"name":"100 Hz 至 2 kHz","range":"30 mV 至 50 mV","cmc":"0,018 %"},{"name":"2 kHz 至 10 kHz","range":"30 mV 至 50 mV","cmc":"0,024 %"},{"name":"10 kHz 至 30 kHz","range":"30 mV 至 50 mV","cmc":"0,047 %"},{"name":"30 kHz 至 100 kHz","range":"30 mV 至 50 mV","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"30 mV 至 50 mV","cmc":"0,39 %"},{"name":"300 kHz 至 1 MHz","range":"30 mV 至 50 mV","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"50 mV 至 100 mV","cmc":"0,022 %"},{"name":"40 Hz 至 100 Hz","range":"50 mV 至 100 mV","cmc":"0,020 %"},{"name":"100 Hz 至 2 kHz","range":"50 mV 至 100 mV","cmc":"0,015 %"},{"name":"2 kHz 至 10 kHz","range":"50 mV 至 100 mV","cmc":"0,019 %"},{"name":"10 kHz 至 30 kHz","range":"50 mV 至 100 mV","cmc":"0,044 %"},{"name":"30 kHz 至 100 kHz","range":"50 mV 至 100 mV","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"50 mV 至 100 mV","cmc":"0,38 %"},{"name":"300 kHz 至 1 MHz","range":"50 mV 至 100 mV","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"100 mV 至 150 mV","cmc":"0,018 %"},{"name":"40 Hz 至 100 Hz","range":"100 mV 至 150 mV","cmc":"0,016 %"},{"name":"100 Hz 至 2 kHz","range":"100 mV 至 150 mV","cmc":"0,013 %"},{"name":"2 kHz 至 10 kHz","range":"100 mV 至 150 mV","cmc":"0,015 %"},{"name":"10 kHz 至 30 kHz","range":"100 mV 至 150 mV","cmc":"0,039 %"},{"name":"30 kHz 至 100 kHz","range":"100 mV 至 150 mV","cmc":"0,091 %"},{"name":"100 kHz 至 300 kHz","range":"100 mV 至 150 mV","cmc":"0,45 %"},{"name":"300 kHz 至 1 MHz","range":"100 mV 至 150 mV","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"150 mV 至 200 mV","cmc":"0,016 %"},{"name":"40 Hz 至 100 Hz","range":"150 mV 至 200 mV","cmc":"0,014 %"},{"name":"100 Hz 至 2 kHz","range":"150 mV 至 200 mV","cmc":"0,012 %"},{"name":"2 kHz 至 10 kHz","range":"150 mV 至 200 mV","cmc":"0,014 %"},{"name":"10 kHz 至 30 kHz","range":"150 mV 至 200 mV","cmc":"0,036 %"},{"name":"30 kHz 至 100 kHz","range":"150 mV 至 200 mV","cmc":"0,084 %"},{"name":"100 kHz 至 300 kHz","range":"150 mV 至 200 mV","cmc":"0,43 %"},{"name":"300 kHz 至 1 MHz","range":"150 mV 至 200 mV","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"200 mV 至 300 mV","cmc":"0,021 %"},{"name":"40 Hz 至 100 Hz","range":"200 mV 至 300 mV","cmc":"0,019 %"},{"name":"100 Hz 至 2 kHz","range":"200 mV 至 300 mV","cmc":"0,017 %"},{"name":"2 kHz 至 10 kHz","range":"200 mV 至 300 mV","cmc":"0,019 %"},{"name":"10 kHz 至 30 kHz","range":"200 mV 至 300 mV","cmc":"0,041 %"},{"name":"30 kHz 至 100 kHz","range":"200 mV 至 300 mV","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"200 mV 至 300 mV","cmc":"0,41 %"},{"name":"300 kHz 至 1 MHz","range":"200 mV 至 300 mV","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"300 mV 至 500 mV","cmc":"0,018 %"},{"name":"40 Hz 至 100 Hz","range":"300 mV 至 500 mV","cmc":"0,016 %"},{"name":"100 Hz 至 2 kHz","range":"300 mV 至 500 mV","cmc":"0,014 %"},{"name":"2 kHz 至 10 kHz","range":"300 mV 至 500 mV","cmc":"0,016 %"},{"name":"10 kHz 至 30 kHz","range":"300 mV 至 500 mV","cmc":"0,034 %"},{"name":"30 kHz 至 100 kHz","range":"300 mV 至 500 mV","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"300 mV 至 500 mV","cmc":"0,39 %"},{"name":"300 kHz 至 1 MHz","range":"300 mV 至 500 mV","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"500 mV 至 1 V","cmc":"0,015 %"},{"name":"40 Hz 至 100 Hz","range":"500 mV 至 1 V","cmc":"0,013 %"},{"name":"100 Hz 至 2 kHz","range":"500 mV 至 1 V","cmc":"0,011 %"},{"name":"2 kHz 至 10 kHz","range":"500 mV 至 1 V","cmc":"0,013 %"},{"name":"10 kHz 至 30 kHz","range":"500 mV 至 1 V","cmc":"0,029 %"},{"name":"30 kHz 至 100 kHz","range":"500 mV 至 1 V","cmc":"0,091 %"},{"name":"100 kHz 至 300 kHz","range":"500 mV 至 1 V","cmc":"0,38 %"},{"name":"300 kHz 至 1 MHz","range":"500 mV 至 1 V","cmc":"1,2 %"},{"name":"10 Hz 至 40 Hz","range":"1 V 至 1,5 V","cmc":"0,013 %"},{"name":"40 Hz 至 100 Hz","range":"1 V 至 1,5 V","cmc":"0,011 %"},{"name":"100 Hz 至 2 kHz","range":"1 V 至 1,5 V","cmc":"0,0086 %"},{"name":"2 kHz 至 10 kHz","range":"1 V 至 1,5 V","cmc":"0,011 %"},{"name":"10 kHz 至 30 kHz","range":"1 V 至 1,5 V","cmc":"0,025 %"},{"name":"30 kHz 至 100 kHz","range":"1 V 至 1,5 V","cmc":"0,071 %"},{"name":"100 kHz 至 300 kHz","range":"1 V 至 1,5 V","cmc":"0,45 %"},{"name":"300 kHz 至 1 MHz","range":"1 V 至 1,5 V","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"1,5 V 至 2 V","cmc":"0,012 %"},{"name":"40 Hz 至 100 Hz","range":"1,5 V 至 2 V","cmc":"0,0099 %"},{"name":"100 Hz 至 2 kHz","range":"1,5 V 至 2 V","cmc":"0,0079 %"},{"name":"2 kHz 至 10 kHz","range":"1,5 V 至 2 V","cmc":"0,010 %"},{"name":"10 kHz 至 30 kHz","range":"1,5 V 至 2 V","cmc":"0,024 %"},{"name":"30 kHz 至 100 kHz","range":"1,5 V 至 2 V","cmc":"0,065 %"},{"name":"100 kHz 至 300 kHz","range":"1,5 V 至 2 V","cmc":"0,43 %"},{"name":"300 kHz 至 1 MHz","range":"1,5 V 至 2 V","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"2 V 至 3 V","cmc":"0,021 %"},{"name":"40 Hz 至 100 Hz","range":"2 V 至 3 V","cmc":"0,019 %"},{"name":"100 Hz 至 2 kHz","range":"2 V 至 3 V","cmc":"0,017 %"},{"name":"2 kHz 至 10 kHz","range":"2 V 至 3 V","cmc":"0,019 %"},{"name":"10 kHz 至 30 kHz","range":"2 V 至 3 V","cmc":"0,041 %"},{"name":"30 kHz 至 100 kHz","range":"2 V 至 3 V","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"2 V 至 3 V","cmc":"0,41 %"},{"name":"300 kHz 至 1 MHz","range":"2 V 至 3 V","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"3 V 至 5 V","cmc":"0,018 %"},{"name":"40 Hz 至 100 Hz","range":"3 V 至 5 V","cmc":"0,016 %"},{"name":"100 Hz 至 2 kHz","range":"3 V 至 5 V","cmc":"0,014 %"},{"name":"2 kHz 至 10 kHz","range":"3 V 至 5 V","cmc":"0,016 %"},{"name":"10 kHz 至 30 kHz","range":"3 V 至 5 V","cmc":"0,034 %"},{"name":"30 kHz 至 100 kHz","range":"3 V 至 5 V","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"3 V 至 5 V","cmc":"0,39 %"},{"name":"300 kHz 至 1 MHz","range":"3 V 至 5 V","cmc":"1,3 %"},{"name":"10 Hz 至 40 Hz","range":"5 V 至 10 V","cmc":"0,015 %"},{"name":"40 Hz 至 100 Hz","range":"5 V 至 10 V","cmc":"0,013 %"},{"name":"100 Hz 至 2 kHz","range":"5 V 至 10 V","cmc":"0,011 %"},{"name":"2 kHz 至 10 kHz","range":"5 V 至 10 V","cmc":"0,013 %"},{"name":"10 kHz 至 30 kHz","range":"5 V 至 10 V","cmc":"0,029 %"},{"name":"30 kHz 至 100 kHz","range":"5 V 至 10 V","cmc":"0,091 %"},{"name":"100 kHz 至 300 kHz","range":"5 V 至 10 V","cmc":"0,38 %"},{"name":"300 kHz 至 1 MHz","range":"5 V 至 10 V","cmc":"1,2 %"},{"name":"10 Hz 至 40 Hz","range":"10 V 至 15 V","cmc":"0,013 %"},{"name":"40 Hz 至 100 Hz","range":"10 V 至 15 V","cmc":"0,011 %"},{"name":"100 Hz 至 2 kHz","range":"10 V 至 15 V","cmc":"0,0086 %"},{"name":"2 kHz 至 10 kHz","range":"10 V 至 15 V","cmc":"0,011 %"},{"name":"10 kHz 至 30 kHz","range":"10 V 至 15 V","cmc":"0,025 %"},{"name":"30 kHz 至 100 kHz","range":"10 V 至 15 V","cmc":"0,071 %"},{"name":"100 kHz 至 300 kHz","range":"10 V 至 15 V","cmc":"0,51 %"},{"name":"300 kHz 至 1 MHz","range":"10 V 至 15 V","cmc":"3,1 %"},{"name":"10 Hz 至 40 Hz","range":"15 V 至 20 V","cmc":"0,012 %"},{"name":"40 Hz 至 100 Hz","range":"15 V 至 20 V","cmc":"0,0099 %"},{"name":"100 Hz 至 2 kHz","range":"15 V 至 20 V","cmc":"0,0079 %"},{"name":"2 kHz 至 10 kHz","range":"15 V 至 20 V","cmc":"0,010 %"},{"name":"10 kHz 至 30 kHz","range":"15 V 至 20 V","cmc":"0,024 %"},{"name":"30 kHz 至 100 kHz","range":"15 V 至 20 V","cmc":"0,065 %"},{"name":"100 kHz 至 300 kHz","range":"15 V 至 20 V","cmc":"0,44 %"},{"name":"300 kHz 至 1 MHz","range":"15 V 至 20 V","cmc":"2,4 %"},{"name":"10 Hz 至 40 Hz","range":"20 V 至 30 V","cmc":"0,021 %"},{"name":"40 Hz 至 100 Hz","range":"20 V 至 30 V","cmc":"0,019 %"},{"name":"100 Hz 至 2 kHz","range":"20 V 至 30 V","cmc":"0,017 %"},{"name":"2 kHz 至 10 kHz","range":"20 V 至 30 V","cmc":"0,019 %"},{"name":"10 kHz 至 30 kHz","range":"20 V 至 30 V","cmc":"0,041 %"},{"name":"30 kHz 至 100 kHz","range":"20 V 至 30 V","cmc":"0,16 %"},{"name":"10 Hz 至 40 Hz","range":"30 V 至 50 V","cmc":"0,018 %"},{"name":"40 Hz 至 100 Hz","range":"30 V 至 50 V","cmc":"0,016 %"},{"name":"100 Hz 至 2 kHz","range":"30 V 至 50 V","cmc":"0,014 %"},{"name":"2 kHz 至 10 kHz","range":"30 V 至 50 V","cmc":"0,016 %"},{"name":"10 kHz 至 30 kHz","range":"30 V 至 50 V","cmc":"0,034 %"},{"name":"30 kHz 至 100 kHz","range":"30 V 至 50 V","cmc":"0,12 %"},{"name":"10 Hz 至 40 Hz","range":"50 V 至 100 V","cmc":"0,015 %"},{"name":"40 Hz 至 100 Hz","range":"50 V 至 100 V","cmc":"0,013 %"},{"name":"100 Hz 至 2 kHz","range":"50 V 至 100 V","cmc":"0,011 %"},{"name":"2 kHz 至 10 kHz","range":"50 V 至 100 V","cmc":"0,013 %"},{"name":"10 kHz 至 30 kHz","range":"50 V 至 100 V","cmc":"0,029 %"},{"name":"30 kHz 至 100 kHz","range":"50 V 至 100 V","cmc":"0,091 %"},{"name":"10 Hz 至 40 Hz","range":"100 V 至 150 V","cmc":"0,013 %"},{"name":"40 Hz 至 100 Hz","range":"100 V 至 150 V","cmc":"0,011 %"},{"name":"100 Hz 至 2 kHz","range":"100 V 至 150 V","cmc":"0,0086 %"},{"name":"2 kHz 至 10 kHz","range":"100 V 至 150 V","cmc":"0,011 %"},{"name":"10 kHz 至 30 kHz","range":"100 V 至 150 V","cmc":"0,025 %"},{"name":"30 kHz 至 100 kHz","range":"100 V 至 150 V","cmc":"0,071 %"},{"name":"10 Hz 至 40 Hz","range":"150 V 至 200 V","cmc":"0,012 %"},{"name":"40 Hz 至 100 Hz","range":"150 V 至 200 V","cmc":"0,0099 %"},{"name":"100 Hz 至 2 kHz","range":"150 V 至 200 V","cmc":"0,0079 %"},{"name":"2 kHz 至 10 kHz","range":"150 V 至 200 V","cmc":"0,010 %"},{"name":"10 kHz 至 30 kHz","range":"150 V 至 200 V","cmc":"0,024 %"},{"name":"30 kHz 至 100 kHz","range":"150 V 至 200 V","cmc":"0,065 %"},{"name":"40 Hz 至 10 kHz","range":"200 V 至 300 V","cmc":"0,020 %"},{"name":"10 kHz 至 30 kHz","range":"200 V 至 300 V","cmc":"0,041 %"},{"name":"30 kHz 至 100 kHz","range":"200 V 至 300 V","cmc":"0,11 %"},{"name":"40 Hz 至 10 kHz","range":"300 V 至 400 V","cmc":"0,017 %"},{"name":"10 kHz 至 30 kHz","range":"300 V 至 400 V","cmc":"0,034 %"},{"name":"30 kHz 至 100 kHz","range":"300 V 至 400 V","cmc":"0,077 %"},{"name":"40 Hz 至 10 kHz","range":"400 V 至 500 V","cmc":"0,016 %"},{"name":"10 kHz 至 20 kHz","range":"400 V 至 500 V","cmc":"0,035 %"},{"name":"20 kHz 至 30 kHz","range":"400 V 至 500 V","cmc":"0,039 %"},{"name":"30 kHz 至 100 kHz","range":"400 V 至 500 V","cmc":"0,063 %"},{"name":"40 Hz 至 10 kHz","range":"500 V 至 600 V","cmc":"0,017 %"},{"name":"10 kHz 至 20 kHz","range":"500 V 至 600 V","cmc":"0,040 %"},{"name":"20 kHz 至 30 kHz","range":"500 V 至 600 V","cmc":"0,049 %"},{"name":"30 kHz 至 100 kHz","range":"500 V 至 600 V","cmc":"0,065 %"},{"name":"40 Hz 至 10 kHz","range":"600 V 至 700 V","cmc":"0,019 %"},{"name":"10 kHz 至 20 kHz","range":"600 V 至 700 V","cmc":"0,049 %"},{"name":"20 kHz 至 30 kHz","range":"600 V 至 700 V","cmc":"0,065 %"},{"name":"30 kHz 至 100 kHz","range":"600 V 至 700 V","cmc":"0,077 %"},{"name":"40 Hz 至 10 kHz","range":"700 V 至 800 V","cmc":"0,023 %"},{"name":"10 kHz 至 20 kHz","range":"700 V 至 800 V","cmc":"0,061 %"},{"name":"20 kHz 至 30 kHz","range":"700 V 至 800 V","cmc":"0,086 %"},{"name":"30 kHz 至 100 kHz","range":"700 V 至 800 V","cmc":"0,095 %"},{"name":"40 Hz 至 10 kHz","range":"800 V 至 900 V","cmc":"0,027 %"},{"name":"10 kHz 至 20 kHz","range":"800 V 至 900 V","cmc":"0,076 %"},{"name":"20 kHz 至 100 kHz","range":"800 V 至 900 V","cmc":"0,12 %"},{"name":"40 Hz 至 10 kHz","range":"900 V 至 1000 V","cmc":"0,032 %"},{"name":"10 kHz 至 20 kHz","range":"900 V 至 1000 V","cmc":"0,094 %"},{"name":"20 kHz 至 100 kHz","range":"900 V 至 1000 V","cmc":"0,15 %"},{"name":"40 Hz 至 10 kHz","range":"1000 V 至 1050 V","cmc":"0,034 %"},{"name":"10 kHz 至 20 kHz","range":"1000 V 至 1050 V","cmc":"0,11 %"},{"name":"20 kHz 至 100 kHz","range":"1000 V 至 1050 V","cmc":"0,16 %"}],"parameters_cs":[{"name":"10 Hz až 40 Hz","range":"1,2 mV až 2 mV","cmc":"4,4 µV"},{"name":"40 Hz až 1 kHz","range":"1,2 mV až 2 mV","cmc":"2,1 µV"},{"name":"1 kHz až 20 kHz","range":"1,2 mV až 2 mV","cmc":"2,3 µV"},{"name":"20 kHz až 50 kHz","range":"1,2 mV až 2 mV","cmc":"3,8 µV"},{"name":"50 kHz až 100 kHz","range":"1,2 mV až 2 mV","cmc":"13 µV"},{"name":"10 Hz až 100 Hz","range":"2 mV až 4 mV","cmc":"4,6 µV"},{"name":"100 Hz až 2 kHz","range":"2 mV až 4 mV","cmc":"2,5 µV"},{"name":"2 kHz až 10 kHz","range":"2 mV až 4 mV","cmc":"4,5 µV"},{"name":"10 kHz až 50 kHz","range":"2 mV až 4 mV","cmc":"6,3 µV"},{"name":"30 kHz až 100 kHz","range":"2 mV až 4 mV","cmc":"23 µV"},{"name":"10 Hz až 40 Hz","range":"4 mV až 10 mV","cmc":"5,4 µV"},{"name":"40 Hz až 100 Hz","range":"4 mV až 10 mV","cmc":"5,2 µV"},{"name":"100 Hz až 2 kHz","range":"4 mV až 10 mV","cmc":"3,1 µV"},{"name":"2 kHz až 10 kHz","range":"4 mV až 10 mV","cmc":"5,1 µV"},{"name":"10 kHz až 30 kHz","range":"4 mV až 10 mV","cmc":"12 µV"},{"name":"30 kHz až 100 kHz","range":"4 mV až 10 mV","cmc":"28 µV"},{"name":"50 kHz až 100 kHz","range":"4 mV až 10 mV","cmc":"35 µV"},{"name":"10 Hz až 40 Hz","range":"10 mV až 15 mV","cmc":"6,0 µV"},{"name":"40 Hz až 100 Hz","range":"10 mV až 15 mV","cmc":"5,7 µV"},{"name":"100 Hz až 2 kHz","range":"10 mV až 15 mV","cmc":"3,6 µV"},{"name":"2 kHz až 10 kHz","range":"10 mV až 15 mV","cmc":"5,6 µV"},{"name":"10 kHz až 30 kHz","range":"10 mV až 15 mV","cmc":"13 µV"},{"name":"30 kHz až 100 kHz","range":"10 mV až 15 mV","cmc":"31 µV"},{"name":"10 Hz až 40 Hz","range":"15 mV až 20 mV","cmc":"6,7 µV"},{"name":"40 Hz až 100 Hz","range":"15 mV až 20 mV","cmc":"6,3 µV"},{"name":"100 Hz až 2 kHz","range":"15 mV až 20 mV","cmc":"4,2 µV"},{"name":"2 kHz až 10 kHz","range":"15 mV až 20 mV","cmc":"6,2 µV"},{"name":"10 kHz až 30 kHz","range":"15 mV až 20 mV","cmc":"11 µV"},{"name":"30 kHz až 100 kHz","range":"15 mV až 20 mV","cmc":"23 µV"},{"name":"100 kHz až 300 kHz","range":"15 mV až 20 mV","cmc":"82 µV"},{"name":"300 kHz až 1 MHz","range":"15 mV až 20 mV","cmc":"0,19 mV"},{"name":"10 Hz až 40 Hz","range":"20 mV až 30 mV","cmc":"0,034 %"},{"name":"40 Hz až 100 Hz","range":"20 mV až 30 mV","cmc":"0,032 %"},{"name":"100 Hz až 2 kHz","range":"20 mV až 30 mV","cmc":"0,021 %"},{"name":"2 kHz až 10 kHz","range":"20 mV až 30 mV","cmc":"0,031 %"},{"name":"10 kHz až 30 kHz","range":"20 mV až 30 mV","cmc":"0,053 %"},{"name":"30 kHz až 100 kHz","range":"20 mV až 30 mV","cmc":"0,12 %"},{"name":"100 kHz až 300 kHz","range":"20 mV až 30 mV","cmc":"0,41 %"},{"name":"300 kHz až 1 MHz","range":"20 mV až 30 mV","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"30 mV až 50 mV","cmc":"0,027 %"},{"name":"40 Hz až 100 Hz","range":"30 mV až 50 mV","cmc":"0,025 %"},{"name":"100 Hz až 2 kHz","range":"30 mV až 50 mV","cmc":"0,018 %"},{"name":"2 kHz až 10 kHz","range":"30 mV až 50 mV","cmc":"0,024 %"},{"name":"10 kHz až 30 kHz","range":"30 mV až 50 mV","cmc":"0,047 %"},{"name":"30 kHz až 100 kHz","range":"30 mV až 50 mV","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"30 mV až 50 mV","cmc":"0,39 %"},{"name":"300 kHz až 1 MHz","range":"30 mV až 50 mV","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"50 mV až 100 mV","cmc":"0,022 %"},{"name":"40 Hz až 100 Hz","range":"50 mV až 100 mV","cmc":"0,020 %"},{"name":"100 Hz až 2 kHz","range":"50 mV až 100 mV","cmc":"0,015 %"},{"name":"2 kHz až 10 kHz","range":"50 mV až 100 mV","cmc":"0,019 %"},{"name":"10 kHz až 30 kHz","range":"50 mV až 100 mV","cmc":"0,044 %"},{"name":"30 kHz až 100 kHz","range":"50 mV až 100 mV","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"50 mV až 100 mV","cmc":"0,38 %"},{"name":"300 kHz až 1 MHz","range":"50 mV až 100 mV","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"100 mV až 150 mV","cmc":"0,018 %"},{"name":"40 Hz až 100 Hz","range":"100 mV až 150 mV","cmc":"0,016 %"},{"name":"100 Hz až 2 kHz","range":"100 mV až 150 mV","cmc":"0,013 %"},{"name":"2 kHz až 10 kHz","range":"100 mV až 150 mV","cmc":"0,015 %"},{"name":"10 kHz až 30 kHz","range":"100 mV až 150 mV","cmc":"0,039 %"},{"name":"30 kHz až 100 kHz","range":"100 mV až 150 mV","cmc":"0,091 %"},{"name":"100 kHz až 300 kHz","range":"100 mV až 150 mV","cmc":"0,45 %"},{"name":"300 kHz až 1 MHz","range":"100 mV až 150 mV","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"150 mV až 200 mV","cmc":"0,016 %"},{"name":"40 Hz až 100 Hz","range":"150 mV až 200 mV","cmc":"0,014 %"},{"name":"100 Hz až 2 kHz","range":"150 mV až 200 mV","cmc":"0,012 %"},{"name":"2 kHz až 10 kHz","range":"150 mV až 200 mV","cmc":"0,014 %"},{"name":"10 kHz až 30 kHz","range":"150 mV až 200 mV","cmc":"0,036 %"},{"name":"30 kHz až 100 kHz","range":"150 mV až 200 mV","cmc":"0,084 %"},{"name":"100 kHz až 300 kHz","range":"150 mV až 200 mV","cmc":"0,43 %"},{"name":"300 kHz až 1 MHz","range":"150 mV až 200 mV","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"200 mV až 300 mV","cmc":"0,021 %"},{"name":"40 Hz až 100 Hz","range":"200 mV až 300 mV","cmc":"0,019 %"},{"name":"100 Hz až 2 kHz","range":"200 mV až 300 mV","cmc":"0,017 %"},{"name":"2 kHz až 10 kHz","range":"200 mV až 300 mV","cmc":"0,019 %"},{"name":"10 kHz až 30 kHz","range":"200 mV až 300 mV","cmc":"0,041 %"},{"name":"30 kHz až 100 kHz","range":"200 mV až 300 mV","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"200 mV až 300 mV","cmc":"0,41 %"},{"name":"300 kHz až 1 MHz","range":"200 mV až 300 mV","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"300 mV až 500 mV","cmc":"0,018 %"},{"name":"40 Hz až 100 Hz","range":"300 mV až 500 mV","cmc":"0,016 %"},{"name":"100 Hz až 2 kHz","range":"300 mV až 500 mV","cmc":"0,014 %"},{"name":"2 kHz až 10 kHz","range":"300 mV až 500 mV","cmc":"0,016 %"},{"name":"10 kHz až 30 kHz","range":"300 mV až 500 mV","cmc":"0,034 %"},{"name":"30 kHz až 100 kHz","range":"300 mV až 500 mV","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"300 mV až 500 mV","cmc":"0,39 %"},{"name":"300 kHz až 1 MHz","range":"300 mV až 500 mV","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"500 mV až 1 V","cmc":"0,015 %"},{"name":"40 Hz až 100 Hz","range":"500 mV až 1 V","cmc":"0,013 %"},{"name":"100 Hz až 2 kHz","range":"500 mV až 1 V","cmc":"0,011 %"},{"name":"2 kHz až 10 kHz","range":"500 mV až 1 V","cmc":"0,013 %"},{"name":"10 kHz až 30 kHz","range":"500 mV až 1 V","cmc":"0,029 %"},{"name":"30 kHz až 100 kHz","range":"500 mV až 1 V","cmc":"0,091 %"},{"name":"100 kHz až 300 kHz","range":"500 mV až 1 V","cmc":"0,38 %"},{"name":"300 kHz až 1 MHz","range":"500 mV až 1 V","cmc":"1,2 %"},{"name":"10 Hz až 40 Hz","range":"1 V až 1,5 V","cmc":"0,013 %"},{"name":"40 Hz až 100 Hz","range":"1 V až 1,5 V","cmc":"0,011 %"},{"name":"100 Hz až 2 kHz","range":"1 V až 1,5 V","cmc":"0,0086 %"},{"name":"2 kHz až 10 kHz","range":"1 V až 1,5 V","cmc":"0,011 %"},{"name":"10 kHz až 30 kHz","range":"1 V až 1,5 V","cmc":"0,025 %"},{"name":"30 kHz až 100 kHz","range":"1 V až 1,5 V","cmc":"0,071 %"},{"name":"100 kHz až 300 kHz","range":"1 V až 1,5 V","cmc":"0,45 %"},{"name":"300 kHz až 1 MHz","range":"1 V až 1,5 V","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"1,5 V až 2 V","cmc":"0,012 %"},{"name":"40 Hz až 100 Hz","range":"1,5 V až 2 V","cmc":"0,0099 %"},{"name":"100 Hz až 2 kHz","range":"1,5 V až 2 V","cmc":"0,0079 %"},{"name":"2 kHz až 10 kHz","range":"1,5 V až 2 V","cmc":"0,010 %"},{"name":"10 kHz až 30 kHz","range":"1,5 V až 2 V","cmc":"0,024 %"},{"name":"30 kHz až 100 kHz","range":"1,5 V až 2 V","cmc":"0,065 %"},{"name":"100 kHz až 300 kHz","range":"1,5 V až 2 V","cmc":"0,43 %"},{"name":"300 kHz až 1 MHz","range":"1,5 V až 2 V","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"2 V až 3 V","cmc":"0,021 %"},{"name":"40 Hz až 100 Hz","range":"2 V až 3 V","cmc":"0,019 %"},{"name":"100 Hz až 2 kHz","range":"2 V až 3 V","cmc":"0,017 %"},{"name":"2 kHz až 10 kHz","range":"2 V až 3 V","cmc":"0,019 %"},{"name":"10 kHz až 30 kHz","range":"2 V až 3 V","cmc":"0,041 %"},{"name":"30 kHz až 100 kHz","range":"2 V až 3 V","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"2 V až 3 V","cmc":"0,41 %"},{"name":"300 kHz až 1 MHz","range":"2 V až 3 V","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"3 V až 5 V","cmc":"0,018 %"},{"name":"40 Hz až 100 Hz","range":"3 V až 5 V","cmc":"0,016 %"},{"name":"100 Hz až 2 kHz","range":"3 V až 5 V","cmc":"0,014 %"},{"name":"2 kHz až 10 kHz","range":"3 V až 5 V","cmc":"0,016 %"},{"name":"10 kHz až 30 kHz","range":"3 V až 5 V","cmc":"0,034 %"},{"name":"30 kHz až 100 kHz","range":"3 V až 5 V","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"3 V až 5 V","cmc":"0,39 %"},{"name":"300 kHz až 1 MHz","range":"3 V až 5 V","cmc":"1,3 %"},{"name":"10 Hz až 40 Hz","range":"5 V až 10 V","cmc":"0,015 %"},{"name":"40 Hz až 100 Hz","range":"5 V až 10 V","cmc":"0,013 %"},{"name":"100 Hz až 2 kHz","range":"5 V až 10 V","cmc":"0,011 %"},{"name":"2 kHz až 10 kHz","range":"5 V až 10 V","cmc":"0,013 %"},{"name":"10 kHz až 30 kHz","range":"5 V až 10 V","cmc":"0,029 %"},{"name":"30 kHz až 100 kHz","range":"5 V až 10 V","cmc":"0,091 %"},{"name":"100 kHz až 300 kHz","range":"5 V až 10 V","cmc":"0,38 %"},{"name":"300 kHz až 1 MHz","range":"5 V až 10 V","cmc":"1,2 %"},{"name":"10 Hz až 40 Hz","range":"10 V až 15 V","cmc":"0,013 %"},{"name":"40 Hz až 100 Hz","range":"10 V až 15 V","cmc":"0,011 %"},{"name":"100 Hz až 2 kHz","range":"10 V až 15 V","cmc":"0,0086 %"},{"name":"2 kHz až 10 kHz","range":"10 V až 15 V","cmc":"0,011 %"},{"name":"10 kHz až 30 kHz","range":"10 V až 15 V","cmc":"0,025 %"},{"name":"30 kHz až 100 kHz","range":"10 V až 15 V","cmc":"0,071 %"},{"name":"100 kHz až 300 kHz","range":"10 V až 15 V","cmc":"0,51 %"},{"name":"300 kHz až 1 MHz","range":"10 V až 15 V","cmc":"3,1 %"},{"name":"10 Hz až 40 Hz","range":"15 V až 20 V","cmc":"0,012 %"},{"name":"40 Hz až 100 Hz","range":"15 V až 20 V","cmc":"0,0099 %"},{"name":"100 Hz až 2 kHz","range":"15 V až 20 V","cmc":"0,0079 %"},{"name":"2 kHz až 10 kHz","range":"15 V až 20 V","cmc":"0,010 %"},{"name":"10 kHz až 30 kHz","range":"15 V až 20 V","cmc":"0,024 %"},{"name":"30 kHz až 100 kHz","range":"15 V až 20 V","cmc":"0,065 %"},{"name":"100 kHz až 300 kHz","range":"15 V až 20 V","cmc":"0,44 %"},{"name":"300 kHz až 1 MHz","range":"15 V až 20 V","cmc":"2,4 %"},{"name":"10 Hz až 40 Hz","range":"20 V až 30 V","cmc":"0,021 %"},{"name":"40 Hz až 100 Hz","range":"20 V až 30 V","cmc":"0,019 %"},{"name":"100 Hz až 2 kHz","range":"20 V až 30 V","cmc":"0,017 %"},{"name":"2 kHz až 10 kHz","range":"20 V až 30 V","cmc":"0,019 %"},{"name":"10 kHz až 30 kHz","range":"20 V až 30 V","cmc":"0,041 %"},{"name":"30 kHz až 100 kHz","range":"20 V až 30 V","cmc":"0,16 %"},{"name":"10 Hz až 40 Hz","range":"30 V až 50 V","cmc":"0,018 %"},{"name":"40 Hz až 100 Hz","range":"30 V až 50 V","cmc":"0,016 %"},{"name":"100 Hz až 2 kHz","range":"30 V až 50 V","cmc":"0,014 %"},{"name":"2 kHz až 10 kHz","range":"30 V až 50 V","cmc":"0,016 %"},{"name":"10 kHz až 30 kHz","range":"30 V až 50 V","cmc":"0,034 %"},{"name":"30 kHz až 100 kHz","range":"30 V až 50 V","cmc":"0,12 %"},{"name":"10 Hz až 40 Hz","range":"50 V až 100 V","cmc":"0,015 %"},{"name":"40 Hz až 100 Hz","range":"50 V až 100 V","cmc":"0,013 %"},{"name":"100 Hz až 2 kHz","range":"50 V až 100 V","cmc":"0,011 %"},{"name":"2 kHz až 10 kHz","range":"50 V až 100 V","cmc":"0,013 %"},{"name":"10 kHz až 30 kHz","range":"50 V až 100 V","cmc":"0,029 %"},{"name":"30 kHz až 100 kHz","range":"50 V až 100 V","cmc":"0,091 %"},{"name":"10 Hz až 40 Hz","range":"100 V až 150 V","cmc":"0,013 %"},{"name":"40 Hz až 100 Hz","range":"100 V až 150 V","cmc":"0,011 %"},{"name":"100 Hz až 2 kHz","range":"100 V až 150 V","cmc":"0,0086 %"},{"name":"2 kHz až 10 kHz","range":"100 V až 150 V","cmc":"0,011 %"},{"name":"10 kHz až 30 kHz","range":"100 V až 150 V","cmc":"0,025 %"},{"name":"30 kHz až 100 kHz","range":"100 V až 150 V","cmc":"0,071 %"},{"name":"10 Hz až 40 Hz","range":"150 V až 200 V","cmc":"0,012 %"},{"name":"40 Hz až 100 Hz","range":"150 V až 200 V","cmc":"0,0099 %"},{"name":"100 Hz až 2 kHz","range":"150 V až 200 V","cmc":"0,0079 %"},{"name":"2 kHz až 10 kHz","range":"150 V až 200 V","cmc":"0,010 %"},{"name":"10 kHz až 30 kHz","range":"150 V až 200 V","cmc":"0,024 %"},{"name":"30 kHz až 100 kHz","range":"150 V až 200 V","cmc":"0,065 %"},{"name":"40 Hz až 10 kHz","range":"200 V až 300 V","cmc":"0,020 %"},{"name":"10 kHz až 30 kHz","range":"200 V až 300 V","cmc":"0,041 %"},{"name":"30 kHz až 100 kHz","range":"200 V až 300 V","cmc":"0,11 %"},{"name":"40 Hz až 10 kHz","range":"300 V až 400 V","cmc":"0,017 %"},{"name":"10 kHz až 30 kHz","range":"300 V až 400 V","cmc":"0,034 %"},{"name":"30 kHz až 100 kHz","range":"300 V až 400 V","cmc":"0,077 %"},{"name":"40 Hz až 10 kHz","range":"400 V až 500 V","cmc":"0,016 %"},{"name":"10 kHz až 20 kHz","range":"400 V až 500 V","cmc":"0,035 %"},{"name":"20 kHz až 30 kHz","range":"400 V až 500 V","cmc":"0,039 %"},{"name":"30 kHz až 100 kHz","range":"400 V až 500 V","cmc":"0,063 %"},{"name":"40 Hz až 10 kHz","range":"500 V až 600 V","cmc":"0,017 %"},{"name":"10 kHz až 20 kHz","range":"500 V až 600 V","cmc":"0,040 %"},{"name":"20 kHz až 30 kHz","range":"500 V až 600 V","cmc":"0,049 %"},{"name":"30 kHz až 100 kHz","range":"500 V až 600 V","cmc":"0,065 %"},{"name":"40 Hz až 10 kHz","range":"600 V až 700 V","cmc":"0,019 %"},{"name":"10 kHz až 20 kHz","range":"600 V až 700 V","cmc":"0,049 %"},{"name":"20 kHz až 30 kHz","range":"600 V až 700 V","cmc":"0,065 %"},{"name":"30 kHz až 100 kHz","range":"600 V až 700 V","cmc":"0,077 %"},{"name":"40 Hz až 10 kHz","range":"700 V až 800 V","cmc":"0,023 %"},{"name":"10 kHz až 20 kHz","range":"700 V až 800 V","cmc":"0,061 %"},{"name":"20 kHz až 30 kHz","range":"700 V až 800 V","cmc":"0,086 %"},{"name":"30 kHz až 100 kHz","range":"700 V až 800 V","cmc":"0,095 %"},{"name":"40 Hz až 10 kHz","range":"800 V až 900 V","cmc":"0,027 %"},{"name":"10 kHz až 20 kHz","range":"800 V až 900 V","cmc":"0,076 %"},{"name":"20 kHz až 100 kHz","range":"800 V až 900 V","cmc":"0,12 %"},{"name":"40 Hz až 10 kHz","range":"900 V až 1000 V","cmc":"0,032 %"},{"name":"10 kHz až 20 kHz","range":"900 V až 1000 V","cmc":"0,094 %"},{"name":"20 kHz až 100 kHz","range":"900 V až 1000 V","cmc":"0,15 %"},{"name":"40 Hz až 10 kHz","range":"1000 V až 1050 V","cmc":"0,034 %"},{"name":"10 kHz až 20 kHz","range":"1000 V až 1050 V","cmc":"0,11 %"},{"name":"20 kHz až 100 kHz","range":"1000 V až 1050 V","cmc":"0,16 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 40 Hz od 1,2 mV do 2 mV CMC 4,4 µV\n40 Hz do 1 kHz od 1,2 mV do 2 mV CMC 2,1 µV\n1 kHz do 20 kHz od 1,2 mV do 2 mV CMC 2,3 µV\n20 kHz do 50 kHz od 1,2 mV do 2 mV CMC 3,8 µV\n50 kHz do 100 kHz od 1,2 mV do 2 mV CMC 13 µV\n10 Hz do 100 Hz od 2 mV do 4 mV CMC 4,6 µV\n100 Hz do 2 kHz od 2 mV do 4 mV CMC 2,5 µV\n2 kHz do 10 kHz od 2 mV do 4 mV CMC 4,5 µV\n10 kHz do 50 kHz od 2 mV do 4 mV CMC 6,3 µV\n30 kHz do 100 kHz od 2 mV do 4 mV CMC 23 µV\n10 Hz do 40 Hz od 4 mV do 10 mV CMC 5,4 µV\n40 Hz do 100 Hz od 4 mV do 10 mV CMC 5,2 µV\n100 Hz do 2 kHz od 4 mV do 10 mV CMC 3,1 µV\n2 kHz do 10 kHz od 4 mV do 10 mV CMC 5,1 µV\n10 kHz do 30 kHz od 4 mV do 10 mV CMC 12 µV\n30 kHz do 100 kHz od 4 mV do 10 mV CMC 28 µV\n50 kHz do 100 kHz od 4 mV do 10 mV CMC 35 µV\n10 Hz do 40 Hz od 10 mV do 15 mV CMC 6,0 µV\n40 Hz do 100 Hz od 10 mV do 15 mV CMC 5,7 µV\n100 Hz do 2 kHz od 10 mV do 15 mV CMC 3,6 µV\n2 kHz do 10 kHz od 10 mV do 15 mV CMC 5,6 µV\n10 kHz do 30 kHz od 10 mV do 15 mV CMC 13 µV\n30 kHz do 100 kHz od 10 mV do 15 mV CMC 31 µV\n10 Hz do 40 Hz od 15 mV do 20 mV CMC 6,7 µV\n40 Hz do 100 Hz od 15 mV do 20 mV CMC 6,3 µV\n100 Hz do 2 kHz od 15 mV do 20 mV CMC 4,2 µV\n2 kHz do 10 kHz od 15 mV do 20 mV CMC 6,2 µV\n10 kHz do 30 kHz od 15 mV do 20 mV CMC 11 µV\n30 kHz do 100 kHz od 15 mV do 20 mV CMC 23 µV\n100 kHz do 300 kHz od 15 mV do 20 mV CMC 82 µV\n300 kHz do 1 MHz od 15 mV do 20 mV CMC 0,19 mV\n10 Hz do 40 Hz od 20 mV do 30 mV CMC 0,034 %\n40 Hz do 100 Hz od 20 mV do 30 mV CMC 0,032 %\n100 Hz do 2 kHz od 20 mV do 30 mV CMC 0,021 %\n2 kHz do 10 kHz od 20 mV do 30 mV CMC 0,031 %\n10 kHz do 30 kHz od 20 mV do 30 mV CMC 0,053 %\n30 kHz do 100 kHz od 20 mV do 30 mV CMC 0,12 %\n100 kHz do 300 kHz od 20 mV do 30 mV CMC 0,41 %\n300 kHz do 1 MHz od 20 mV do 30 mV CMC 1,3 %\n10 Hz do 40 Hz od 30 mV do 50 mV CMC 0,027 %\n40 Hz do 100 Hz od 30 mV do 50 mV CMC 0,025 %\n100 Hz do 2 kHz od 30 mV do 50 mV CMC 0,018 %\n2 kHz do 10 kHz od 30 mV do 50 mV CMC 0,024 %\n10 kHz do 30 kHz od 30 mV do 50 mV CMC 0,047 %\n30 kHz do 100 kHz od 30 mV do 50 mV CMC 0,11 %\n100 kHz do 300 kHz od 30 mV do 50 mV CMC 0,39 %\n300 kHz do 1 MHz od 30 mV do 50 mV CMC 1,3 %\n10 Hz do 40 Hz od 50 mV do 100 mV CMC 0,022 %\n40 Hz do 100 Hz od 50 mV do 100 mV CMC 0,020 %\n100 Hz do 2 kHz od 50 mV do 100 mV CMC 0,015 %\n2 kHz do 10 kHz od 50 mV do 100 mV CMC 0,019 %\n10 kHz do 30 kHz od 50 mV do 100 mV CMC 0,044 %\n30 kHz do 100 kHz od 50 mV do 100 mV CMC 0,11 %\n100 kHz do 300 kHz od 50 mV do 100 mV CMC 0,38 %\n300 kHz do 1 MHz od 50 mV do 100 mV CMC 1,3 %\n10 Hz do 40 Hz od 100 mV do 150 mV CMC 0,018 %\n40 Hz do 100 Hz od 100 mV do 150 mV CMC 0,016 %\n100 Hz do 2 kHz od 100 mV do 150 mV CMC 0,013 %\n2 kHz do 10 kHz od 100 mV do 150 mV CMC 0,015 %\n10 kHz do 30 kHz od 100 mV do 150 mV CMC 0,039 %\n30 kHz do 100 kHz od 100 mV do 150 mV CMC 0,091 %\n100 kHz do 300 kHz od 100 mV do 150 mV CMC 0,45 %\n300 kHz do 1 MHz od 100 mV do 150 mV CMC 1,3 %\n10 Hz do 40 Hz od 150 mV do 200 mV CMC 0,016 %\n40 Hz do 100 Hz od 150 mV do 200 mV CMC 0,014 %\n100 Hz do 2 kHz od 150 mV do 200 mV CMC 0,012 %\n2 kHz do 10 kHz od 150 mV do 200 mV CMC 0,014 %\n10 kHz do 30 kHz od 150 mV do 200 mV CMC 0,036 %\n30 kHz do 100 kHz od 150 mV do 200 mV CMC 0,084 %\n100 kHz do 300 kHz od 150 mV do 200 mV CMC 0,43 %\n300 kHz do 1 MHz od 150 mV do 200 mV CMC 1,3 %\n10 Hz do 40 Hz od 200 mV do 300 mV CMC 0,021 %\n40 Hz do 100 Hz od 200 mV do 300 mV CMC 0,019 %\n100 Hz do 2 kHz od 200 mV do 300 mV CMC 0,017 %\n2 kHz do 10 kHz od 200 mV do 300 mV CMC 0,019 %\n10 kHz do 30 kHz od 200 mV do 300 mV CMC 0,041 %\n30 kHz do 100 kHz od 200 mV do 300 mV CMC 0,11 %\n100 kHz do 300 kHz od 200 mV do 300 mV CMC 0,41 %\n300 kHz do 1 MHz od 200 mV do 300 mV CMC 1,3 %\n10 Hz do 40 Hz od 300 mV do 500 mV CMC 0,018 %\n40 Hz do 100 Hz od 300 mV do 500 mV CMC 0,016 %\n100 Hz do 2 kHz od 300 mV do 500 mV CMC 0,014 %\n2 kHz do 10 kHz od 300 mV do 500 mV CMC 0,016 %\n10 kHz do 30 kHz od 300 mV do 500 mV CMC 0,034 %\n30 kHz do 100 kHz od 300 mV do 500 mV CMC 0,11 %\n100 kHz do 300 kHz od 300 mV do 500 mV CMC 0,39 %\n300 kHz do 1 MHz od 300 mV do 500 mV CMC 1,3 %\n10 Hz do 40 Hz od 500 mV do 1 V CMC 0,015 %\n40 Hz do 100 Hz od 500 mV do 1 V CMC 0,013 %\n100 Hz do 2 kHz od 500 mV do 1 V CMC 0,011 %\n2 kHz do 10 kHz od 500 mV do 1 V CMC 0,013 %\n10 kHz do 30 kHz od 500 mV do 1 V CMC 0,029 %\n30 kHz do 100 kHz od 500 mV do 1 V CMC 0,091 %\n100 kHz do 300 kHz od 500 mV do 1 V CMC 0,38 %\n300 kHz do 1 MHz od 500 mV do 1 V CMC 1,2 %\n10 Hz do 40 Hz od 1 V do 1,5 V CMC 0,013 %\n40 Hz do 100 Hz od 1 V do 1,5 V CMC 0,011 %\n100 Hz do 2 kHz od 1 V do 1,5 V CMC 0,0086 %\n2 kHz do 10 kHz od 1 V do 1,5 V CMC 0,011 %\n10 kHz do 30 kHz od 1 V do 1,5 V CMC 0,025 %\n30 kHz do 100 kHz od 1 V do 1,5 V CMC 0,071 %\n100 kHz do 300 kHz od 1 V do 1,5 V CMC 0,45 %\n300 kHz do 1 MHz od 1 V do 1,5 V CMC 1,3 %\n10 Hz do 40 Hz od 1,5 V do 2 V CMC 0,012 %\n40 Hz do 100 Hz od 1,5 V do 2 V CMC 0,0099 %\n100 Hz do 2 kHz od 1,5 V do 2 V CMC 0,0079 %\n2 kHz do 10 kHz od 1,5 V do 2 V CMC 0,010 %\n10 kHz do 30 kHz od 1,5 V do 2 V CMC 0,024 %\n30 kHz do 100 kHz od 1,5 V do 2 V CMC 0,065 %\n100 kHz do 300 kHz od 1,5 V do 2 V CMC 0,43 %\n300 kHz do 1 MHz od 1,5 V do 2 V CMC 1,3 %\n10 Hz do 40 Hz od 2 V do 3 V CMC 0,021 %\n40 Hz do 100 Hz od 2 V do 3 V CMC 0,019 %\n100 Hz do 2 kHz od 2 V do 3 V CMC 0,017 %\n2 kHz do 10 kHz od 2 V do 3 V CMC 0,019 %\n10 kHz do 30 kHz od 2 V do 3 V CMC 0,041 %\n30 kHz do 100 kHz od 2 V do 3 V CMC 0,11 %\n100 kHz do 300 kHz od 2 V do 3 V CMC 0,41 %\n300 kHz do 1 MHz od 2 V do 3 V CMC 1,3 %\n10 Hz do 40 Hz od 3 V do 5 V CMC 0,018 %\n40 Hz do 100 Hz od 3 V do 5 V CMC 0,016 %\n100 Hz do 2 kHz od 3 V do 5 V CMC 0,014 %\n2 kHz do 10 kHz od 3 V do 5 V CMC 0,016 %\n10 kHz do 30 kHz od 3 V do 5 V CMC 0,034 %\n30 kHz do 100 kHz od 3 V do 5 V CMC 0,11 %\n100 kHz do 300 kHz od 3 V do 5 V CMC 0,39 %\n300 kHz do 1 MHz od 3 V do 5 V CMC 1,3 %\n10 Hz do 40 Hz od 5 V do 10 V CMC 0,015 %\n40 Hz do 100 Hz od 5 V do 10 V CMC 0,013 %\n100 Hz do 2 kHz od 5 V do 10 V CMC 0,011 %\n2 kHz do 10 kHz od 5 V do 10 V CMC 0,013 %\n10 kHz do 30 kHz od 5 V do 10 V CMC 0,029 %\n30 kHz do 100 kHz od 5 V do 10 V CMC 0,091 %\n100 kHz do 300 kHz od 5 V do 10 V CMC 0,38 %\n300 kHz do 1 MHz od 5 V do 10 V CMC 1,2 %\n10 Hz do 40 Hz od 10 V do 15 V CMC 0,013 %\n40 Hz do 100 Hz od 10 V do 15 V CMC 0,011 %\n100 Hz do 2 kHz od 10 V do 15 V CMC 0,0086 %\n2 kHz do 10 kHz od 10 V do 15 V CMC 0,011 %\n10 kHz do 30 kHz od 10 V do 15 V CMC 0,025 %\n30 kHz do 100 kHz od 10 V do 15 V CMC 0,071 %\n100 kHz do 300 kHz od 10 V do 15 V CMC 0,51 %\n300 kHz do 1 MHz od 10 V do 15 V CMC 3,1 %\n10 Hz do 40 Hz od 15 V do 20 V CMC 0,012 %\n40 Hz do 100 Hz od 15 V do 20 V CMC 0,0099 %\n100 Hz do 2 kHz od 15 V do 20 V CMC 0,0079 %\n2 kHz do 10 kHz od 15 V do 20 V CMC 0,010 %\n10 kHz do 30 kHz od 15 V do 20 V CMC 0,024 %\n30 kHz do 100 kHz od 15 V do 20 V CMC 0,065 %\n100 kHz do 300 kHz od 15 V do 20 V CMC 0,44 %\n300 kHz do 1 MHz od 15 V do 20 V CMC 2,4 %\n10 Hz do 40 Hz od 20 V do 30 V CMC 0,021 %\n40 Hz do 100 Hz od 20 V do 30 V CMC 0,019 %\n100 Hz do 2 kHz od 20 V do 30 V CMC 0,017 %\n2 kHz do 10 kHz od 20 V do 30 V CMC 0,019 %\n10 kHz do 30 kHz od 20 V do 30 V CMC 0,041 %\n30 kHz do 100 kHz od 20 V do 30 V CMC 0,16 %\n10 Hz do 40 Hz od 30 V do 50 V CMC 0,018 %\n40 Hz do 100 Hz od 30 V do 50 V CMC 0,016 %\n100 Hz do 2 kHz od 30 V do 50 V CMC 0,014 %\n2 kHz do 10 kHz od 30 V do 50 V CMC 0,016 %\n10 kHz do 30 kHz od 30 V do 50 V CMC 0,034 %\n30 kHz do 100 kHz od 30 V do 50 V CMC 0,12 %\n10 Hz do 40 Hz od 50 V do 100 V CMC 0,015 %\n40 Hz do 100 Hz od 50 V do 100 V CMC 0,013 %\n100 Hz do 2 kHz od 50 V do 100 V CMC 0,011 %\n2 kHz do 10 kHz od 50 V do 100 V CMC 0,013 %\n10 kHz do 30 kHz od 50 V do 100 V CMC 0,029 %\n30 kHz do 100 kHz od 50 V do 100 V CMC 0,091 %\n10 Hz do 40 Hz od 100 V do 150 V CMC 0,013 %\n40 Hz do 100 Hz od 100 V do 150 V CMC 0,011 %\n100 Hz do 2 kHz od 100 V do 150 V CMC 0,0086 %\n2 kHz do 10 kHz od 100 V do 150 V CMC 0,011 %\n10 kHz do 30 kHz od 100 V do 150 V CMC 0,025 %\n30 kHz do 100 kHz od 100 V do 150 V CMC 0,071 %\n10 Hz do 40 Hz od 150 V do 200 V CMC 0,012 %\n40 Hz do 100 Hz od 150 V do 200 V CMC 0,0099 %\n100 Hz do 2 kHz od 150 V do 200 V CMC 0,0079 %\n2 kHz do 10 kHz od 150 V do 200 V CMC 0,010 %\n10 kHz do 30 kHz od 150 V do 200 V CMC 0,024 %\n30 kHz do 100 kHz od 150 V do 200 V CMC 0,065 %\n40 Hz do 10 kHz od 200 V do 300 V CMC 0,020 %\n10 kHz do 30 kHz od 200 V do 300 V CMC 0,041 %\n30 kHz do 100 kHz od 200 V do 300 V CMC 0,11 %\n40 Hz do 10 kHz od 300 V do 400 V CMC 0,017 %\n10 kHz do 30 kHz od 300 V do 400 V CMC 0,034 %\n30 kHz do 100 kHz od 300 V do 400 V CMC 0,077 %\n40 Hz do 10 kHz od 400 V do 500 V CMC 0,016 %\n10 kHz do 20 kHz od 400 V do 500 V CMC 0,035 %\n20 kHz do 30 kHz od 400 V do 500 V CMC 0,039 %\n30 kHz do 100 kHz od 400 V do 500 V CMC 0,063 %\n40 Hz do 10 kHz od 500 V do 600 V CMC 0,017 %\n10 kHz do 20 kHz od 500 V do 600 V CMC 0,040 %\n20 kHz do 30 kHz od 500 V do 600 V CMC 0,049 %\n30 kHz do 100 kHz od 500 V do 600 V CMC 0,065 %\n40 Hz do 10 kHz od 600 V do 700 V CMC 0,019 %\n10 kHz do 20 kHz od 600 V do 700 V CMC 0,049 %\n20 kHz do 30 kHz od 600 V do 700 V CMC 0,065 %\n30 kHz do 100 kHz od 600 V do 700 V CMC 0,077 %\n40 Hz do 10 kHz od 700 V do 800 V CMC 0,023 %\n10 kHz do 20 kHz od 700 V do 800 V CMC 0,061 %\n20 kHz do 30 kHz od 700 V do 800 V CMC 0,086 %\n30 kHz do 100 kHz od 700 V do 800 V CMC 0,095 %\n40 Hz do 10 kHz od 800 V do 900 V CMC 0,027 %\n10 kHz do 20 kHz od 800 V do 900 V CMC 0,076 %\n20 kHz do 100 kHz od 800 V do 900 V CMC 0,12 %\n40 Hz do 10 kHz od 900 V do 1000 V CMC 0,032 %\n10 kHz do 20 kHz od 900 V do 1000 V CMC 0,094 %\n20 kHz do 100 kHz od 900 V do 1000 V CMC 0,15 %\n40 Hz do 10 kHz od 1000 V do 1050 V CMC 0,034 %\n10 kHz do 20 kHz od 1000 V do 1050 V CMC 0,11 %\n20 kHz do 100 kHz od 1000 V do 1050 V CMC 0,16 %\nPomiar bezpośredni multimetrem","reference":"TP2, TP21","norm_bases":["TP2","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 10 Hz do 40 Hz od 1,2 mV do 2 mV CMC 4,4 µV 40 Hz do 1 kHz od 1,2 mV do 2 mV CMC 2,1 µV 1 kHz do 20 kHz od 1,2 mV do 2 mV CMC 2,3 µV 20 kHz do 50 kHz od 1,2 mV do 2 mV CMC 3,8 µV 50 kHz do 100 kHz od 1,2 mV do 2 mV CMC 13 µV 10 Hz do 100 Hz od 2 mV do 4 mV CMC 4,6 µV 100 Hz do 2 kHz od 2 mV do 4 mV CMC 2,5 µV 2 kHz do 10 kHz od 2 mV do 4 mV CMC 4,5 µV 10 kHz do 50 kHz od 2 mV do 4 mV CMC 6,3 µV 30 kHz do 100 kHz od 2 mV do 4 mV CMC 23 µV 10 Hz do 40 Hz od 4 mV do 10 mV CMC 5,4 µV 40 Hz do 100 Hz od 4 mV do 10 mV CMC 5,2 µV 100 Hz do 2 kHz od 4 mV do 10 mV CMC 3,1 µV 2 kHz do 10 kHz od 4 mV do 10 mV CMC 5,1 µV 10 kHz do 30 kHz od 4 mV do 10 mV CMC 12 µV 30 kHz do 100 kHz od 4 mV do 10 mV CMC 28 µV 50 kHz do 100 kHz od 4 mV do 10 mV CMC 35 µV 10 Hz do 40 Hz od 10 mV do 15 mV CMC 6,0 µV 40 Hz do 100 Hz od 10 mV do 15 mV CMC 5,7 µV 100 Hz do 2 kHz od 10 mV do 15 mV CMC 3,6 µV 2 kHz do 10 kHz od 10 mV do 15 mV CMC 5,6 µV 10 kHz do 30 kHz od 10 mV do 15 mV CMC 13 µV 30 kHz do 100 kHz od 10 mV do 15 mV CMC 31 µV 10 Hz do 40 Hz od 15 mV do 20 mV CMC 6,7 µV 40 Hz do 100 Hz od 15 mV do 20 mV CMC 6,3 µV 100 Hz do 2 kHz od 15 mV do 20 mV CMC 4,2 µV 2 kHz do 10 kHz od 15 mV do 20 mV CMC 6,2 µV 10 kHz do 30 kHz od 15 mV do 20 mV CMC 11 µV 30 kHz do 100 kHz od 15 mV do 20 mV CMC 23 µV 100 kHz do 300 kHz od 15 mV do 20 mV CMC 82 µV 300 kHz do 1 MHz od 15 mV do 20 mV CMC 0,19 mV 10 Hz do 40 Hz od 20 mV do 30 mV CMC 0,034 % 40 Hz do 100 Hz od 20 mV do 30 mV CMC 0,032 % 100 Hz do 2 kHz od 20 mV do 30 mV CMC 0,021 % 2 kHz do 10 kHz od 20 mV do 30 mV CMC 0,031 % 10 kHz do 30 kHz od 20 mV do 30 mV CMC 0,053 % 30 kHz do 100 kHz od 20 mV do 30 mV CMC 0,12 % 100 kHz do 300 kHz od 20 mV do 30 mV CMC 0,41 % 300 kHz do 1 MHz od 20 mV do 30 mV CMC 1,3 % 10 Hz do 40 Hz od 30 mV do 50 mV CMC 0,027 % 40 Hz do 100 Hz od 30 mV do 50 mV CMC 0,025 % 100 Hz do 2 kHz od 30 mV do 50 mV CMC 0,018 % 2 kHz do 10 kHz od 30 mV do 50 mV CMC 0,024 % 10 kHz do 30 kHz od 30 mV do 50 mV CMC 0,047 % 30 kHz do 100 kHz od 30 mV do 50 mV CMC 0,11 % 100 kHz do 300 kHz od 30 mV do 50 mV CMC 0,39 % 300 kHz do 1 MHz od 30 mV do 50 mV CMC 1,3 % 10 Hz do 40 Hz od 50 mV do 100 mV CMC 0,022 % 40 Hz do 100 Hz od 50 mV do 100 mV CMC 0,020 % 100 Hz do 2 kHz od 50 mV do 100 mV CMC 0,015 % 2 kHz do 10 kHz od 50 mV do 100 mV CMC 0,019 % 10 kHz do 30 kHz od 50 mV do 100 mV CMC 0,044 % 30 kHz do 100 kHz od 50 mV do 100 mV CMC 0,11 % 100 kHz do 300 kHz od 50 mV do 100 mV CMC 0,38 % 300 kHz do 1 MHz od 50 mV do 100 mV CMC 1,3 % 10 Hz do 40 Hz od 100 mV do 150 mV CMC 0,018 % 40 Hz do 100 Hz od 100 mV do 150 mV CMC 0,016 % 100 Hz do 2 kHz od 100 mV do 150 mV CMC 0,013 % 2 kHz do 10 kHz od 100 mV do 150 mV CMC 0,015 % 10 kHz do 30 kHz od 100 mV do 150 mV CMC 0,039 % 30 kHz do 100 kHz od 100 mV do 150 mV CMC 0,091 % 100 kHz do 300 kHz od 100 mV do 150 mV CMC 0,45 % 300 kHz do 1 MHz od 100 mV do 150 mV CMC 1,3 % 10 Hz do 40 Hz od 150 mV do 200 mV CMC 0,016 % 40 Hz do 100 Hz od 150 mV do 200 mV CMC 0,014 % 100 Hz do 2 kHz od 150 mV do 200 mV CMC 0,012 % 2 kHz do 10 kHz od 150 mV do 200 mV CMC 0,014 % 10 kHz do 30 kHz od 150 mV do 200 mV CMC 0,036 % 30 kHz do 100 kHz od 150 mV do 200 mV CMC 0,084 % 100 kHz do 300 kHz od 150 mV do 200 mV CMC 0,43 % 300 kHz do 1 MHz od 150 mV do 200 mV CMC 1,3 % 10 Hz do 40 Hz od 200 mV do 300 mV CMC 0,021 % 40 Hz do 100 Hz od 200 mV do 300 mV CMC 0,019 % 100 Hz do 2 kHz od 200 mV do 300 mV CMC 0,017 % 2 kHz do 10 kHz od 200 mV do 300 mV CMC 0,019 % 10 kHz do 30 kHz od 200 mV do 300 mV CMC 0,041 % 30 kHz do 100 kHz od 200 mV do 300 mV CMC 0,11 % 100 kHz do 300 kHz od 200 mV do 300 mV CMC 0,41 % 300 kHz do 1 MHz od 200 mV do 300 mV CMC 1,3 % 10 Hz do 40 Hz od 300 mV do 500 mV CMC 0,018 % 40 Hz do 100 Hz od 300 mV do 500 mV CMC 0,016 % 100 Hz do 2 kHz od 300 mV do 500 mV CMC 0,014 % 2 kHz do 10 kHz od 300 mV do 500 mV CMC 0,016 % 10 kHz do 30 kHz od 300 mV do 500 mV CMC 0,034 % 30 kHz do 100 kHz od 300 mV do 500 mV CMC 0,11 % 100 kHz do 300 kHz od 300 mV do 500 mV CMC 0,39 % 300 kHz do 1 MHz od 300 mV do 500 mV CMC 1,3 % 10 Hz do 40 Hz od 500 mV do 1 V CMC 0,015 % 40 Hz do 100 Hz od 500 mV do 1 V CMC 0,013 % 100 Hz do 2 kHz od 500 mV do 1 V CMC 0,011 % 2 kHz do 10 kHz od 500 mV do 1 V CMC 0,013 % 10 kHz do 30 kHz od 500 mV do 1 V CMC 0,029 % 30 kHz do 100 kHz od 500 mV do 1 V CMC 0,091 % 100 kHz do 300 kHz od 500 mV do 1 V CMC 0,38 % 300 kHz do 1 MHz od 500 mV do 1 V CMC 1,2 % 10 Hz do 40 Hz od 1 V do 1,5 V CMC 0,013 % 40 Hz do 100 Hz od 1 V do 1,5 V CMC 0,011 % 100 Hz do 2 kHz od 1 V do 1,5 V CMC 0,0086 % 2 kHz do 10 kHz od 1 V do 1,5 V CMC 0,011 % 10 kHz do 30 kHz od 1 V do 1,5 V CMC 0,025 % 30 kHz do 100 kHz od 1 V do 1,5 V CMC 0,071 % 100 kHz do 300 kHz od 1 V do 1,5 V CMC 0,45 % 300 kHz do 1 MHz od 1 V do 1,5 V CMC 1,3 % 10 Hz do 40 Hz od 1,5 V do 2 V CMC 0,012 % 40 Hz do 100 Hz od 1,5 V do 2 V CMC 0,0099 % 100 Hz do 2 kHz od 1,5 V do 2 V CMC 0,0079 % 2 kHz do 10 kHz od 1,5 V do 2 V CMC 0,010 % 10 kHz do 30 kHz od 1,5 V do 2 V CMC 0,024 % 30 kHz do 100 kHz od 1,5 V do 2 V CMC 0,065 % 100 kHz do 300 kHz od 1,5 V do 2 V CMC 0,43 % 300 kHz do 1 MHz od 1,5 V do 2 V CMC 1,3 % 10 Hz do 40 Hz od 2 V do 3 V CMC 0,021 % 40 Hz do 100 Hz od 2 V do 3 V CMC 0,019 % 100 Hz do 2 kHz od 2 V do 3 V CMC 0,017 % 2 kHz do 10 kHz od 2 V do 3 V CMC 0,019 % 10 kHz do 30 kHz od 2 V do 3 V CMC 0,041 % 30 kHz do 100 kHz od 2 V do 3 V CMC 0,11 % 100 kHz do 300 kHz od 2 V do 3 V CMC 0,41 % 300 kHz do 1 MHz od 2 V do 3 V CMC 1,3 % 10 Hz do 40 Hz od 3 V do 5 V CMC 0,018 % 40 Hz do 100 Hz od 3 V do 5 V CMC 0,016 % 100 Hz do 2 kHz od 3 V do 5 V CMC 0,014 % 2 kHz do 10 kHz od 3 V do 5 V CMC 0,016 % 10 kHz do 30 kHz od 3 V do 5 V CMC 0,034 % 30 kHz do 100 kHz od 3 V do 5 V CMC 0,11 % 100 kHz do 300 kHz od 3 V do 5 V CMC 0,39 % 300 kHz do 1 MHz od 3 V do 5 V CMC 1,3 % 10 Hz do 40 Hz od 5 V do 10 V CMC 0,015 % 40 Hz do 100 Hz od 5 V do 10 V CMC 0,013 % 100 Hz do 2 kHz od 5 V do 10 V CMC 0,011 % 2 kHz do 10 kHz od 5 V do 10 V CMC 0,013 % 10 kHz do 30 kHz od 5 V do 10 V CMC 0,029 % 30 kHz do 100 kHz od 5 V do 10 V CMC 0,091 % 100 kHz do 300 kHz od 5 V do 10 V CMC 0,38 % 300 kHz do 1 MHz od 5 V do 10 V CMC 1,2 % 10 Hz do 40 Hz od 10 V do 15 V CMC 0,013 % 40 Hz do 100 Hz od 10 V do 15 V CMC 0,011 % 100 Hz do 2 kHz od 10 V do 15 V CMC 0,0086 % 2 kHz do 10 kHz od 10 V do 15 V CMC 0,011 % 10 kHz do 30 kHz od 10 V do 15 V CMC 0,025 % 30 kHz do 100 kHz od 10 V do 15 V CMC 0,071 % 100 kHz do 300 kHz od 10 V do 15 V CMC 0,51 % 300 kHz do 1 MHz od 10 V do 15 V CMC 3,1 % 10 Hz do 40 Hz od 15 V do 20 V CMC 0,012 % 40 Hz do 100 Hz od 15 V do 20 V CMC 0,0099 % 100 Hz do 2 kHz od 15 V do 20 V CMC 0,0079 % 2 kHz do 10 kHz od 15 V do 20 V CMC 0,010 % 10 kHz do 30 kHz od 15 V do 20 V CMC 0,024 % 30 kHz do 100 kHz od 15 V do 20 V CMC 0,065 % 100 kHz do 300 kHz od 15 V do 20 V CMC 0,44 % 300 kHz do 1 MHz od 15 V do 20 V CMC 2,4 % 10 Hz do 40 Hz od 20 V do 30 V CMC 0,021 % 40 Hz do 100 Hz od 20 V do 30 V CMC 0,019 % 100 Hz do 2 kHz od 20 V do 30 V CMC 0,017 % 2 kHz do 10 kHz od 20 V do 30 V CMC 0,019 % 10 kHz do 30 kHz od 20 V do 30 V CMC 0,041 % 30 kHz do 100 kHz od 20 V do 30 V CMC 0,16 % 10 Hz do 40 Hz od 30 V do 50 V CMC 0,018 % 40 Hz do 100 Hz od 30 V do 50 V CMC 0,016 % 100 Hz do 2 kHz od 30 V do 50 V CMC 0,014 % 2 kHz do 10 kHz od 30 V do 50 V CMC 0,016 % 10 kHz do 30 kHz od 30 V do 50 V CMC 0,034 % 30 kHz do 100 kHz od 30 V do 50 V CMC 0,12 % 10 Hz do 40 Hz od 50 V do 100 V CMC 0,015 % 40 Hz do 100 Hz od 50 V do 100 V CMC 0,013 % 100 Hz do 2 kHz od 50 V do 100 V CMC 0,011 % 2 kHz do 10 kHz od 50 V do 100 V CMC 0,013 % 10 kHz do 30 kHz od 50 V do 100 V CMC 0,029 % 30 kHz do 100 kHz od 50 V do 100 V CMC 0,091 % 10 Hz do 40 Hz od 100 V do 150 V CMC 0,013 % 40 Hz do 100 Hz od 100 V do 150 V CMC 0,011 % 100 Hz do 2 kHz od 100 V do 150 V CMC 0,0086 % 2 kHz do 10 kHz od 100 V do 150 V CMC 0,011 % 10 kHz do 30 kHz od 100 V do 150 V CMC 0,025 % 30 kHz do 100 kHz od 100 V do 150 V CMC 0,071 % 10 Hz do 40 Hz od 150 V do 200 V CMC 0,012 % 40 Hz do 100 Hz od 150 V do 200 V CMC 0,0099 % 100 Hz do 2 kHz od 150 V do 200 V CMC 0,0079 % 2 kHz do 10 kHz od 150 V do 200 V CMC 0,010 % 10 kHz do 30 kHz od 150 V do 200 V CMC 0,024 % 30 kHz do 100 kHz od 150 V do 200 V CMC 0,065 % 40 Hz do 10 kHz od 200 V do 300 V CMC 0,020 % 10 kHz do 30 kHz od 200 V do 300 V CMC 0,041 % 30 kHz do 100 kHz od 200 V do 300 V CMC 0,11 % 40 Hz do 10 kHz od 300 V do 400 V CMC 0,017 % 10 kHz do 30 kHz od 300 V do 400 V CMC 0,034 % 30 kHz do 100 kHz od 300 V do 400 V CMC 0,077 % 40 Hz do 10 kHz od 400 V do 500 V CMC 0,016 % 10 kHz do 20 kHz od 400 V do 500 V CMC 0,035 % 20 kHz do 30 kHz od 400 V do 500 V CMC 0,039 % 30 kHz do 100 kHz od 400 V do 500 V CMC 0,063 % 40 Hz do 10 kHz od 500 V do 600 V CMC 0,017 % 10 kHz do 20 kHz od 500 V do 600 V CMC 0,040 % 20 kHz do 30 kHz od 500 V do 600 V CMC 0,049 % 30 kHz do 100 kHz od 500 V do 600 V CMC 0,065 % 40 Hz do 10 kHz od 600 V do 700 V CMC 0,019 % 10 kHz do 20 kHz od 600 V do 700 V CMC 0,049 % 20 kHz do 30 kHz od 600 V do 700 V CMC 0,065 % 30 kHz do 100 kHz od 600 V do 700 V CMC 0,077 % 40 Hz do 10 kHz od 700 V do 800 V CMC 0,023 % 10 kHz do 20 kHz od 700 V do 800 V CMC 0,061 % 20 kHz do 30 kHz od 700 V do 800 V CMC 0,086 % 30 kHz do 100 kHz od 700 V do 800 V CMC 0,095 % 40 Hz do 10 kHz od 800 V do 900 V CMC 0,027 % 10 kHz do 20 kHz od 800 V do 900 V CMC 0,076 % 20 kHz do 100 kHz od 800 V do 900 V CMC 0,12 % 40 Hz do 10 kHz od 900 V do 1000 V CMC 0,032 % 10 kHz do 20 kHz od 900 V do 1000 V CMC 0,094 % 20 kHz do 100 kHz od 900 V do 1000 V CMC 0,15 % 40 Hz do 10 kHz od 1000 V do 1050 V CMC 0,034 % 10 kHz do 20 kHz od 1000 V do 1050 V CMC 0,11 % 20 kHz do 100 kHz od 1000 V do 1050 V CMC 0,16 % Střídavé napětí / Zdroje střídavého napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 10 Hz až 40 Hz 1,2 mV až 2 mV CMC 4,4 µV 40 Hz až 1 kHz 1,2 mV až 2 mV CMC 2,1 µV 1 kHz až 20 kHz 1,2 mV až 2 mV CMC 2,3 µV 20 kHz až 50 kHz 1,2 mV až 2 mV CMC 3,8 µV 50 kHz až 100 kHz 1,2 mV až 2 mV CMC 13 µV 10 Hz až 100 Hz 2 mV až 4 mV CMC 4,6 µV 100 Hz až 2 kHz 2 mV až 4 mV CMC 2,5 µV 2 kHz až 10 kHz 2 mV až 4 mV CMC 4,5 µV 10 kHz až 50 kHz 2 mV až 4 mV CMC 6,3 µV 30 kHz až 100 kHz 2 mV až 4 mV CMC 23 µV 10 Hz až 40 Hz 4 mV až 10 mV CMC 5,4 µV 40 Hz až 100 Hz 4 mV až 10 mV CMC 5,2 µV 100 Hz až 2 kHz 4 mV až 10 mV CMC 3,1 µV 2 kHz až 10 kHz 4 mV až 10 mV CMC 5,1 µV 10 kHz až 30 kHz 4 mV až 10 mV CMC 12 µV 30 kHz až 100 kHz 4 mV až 10 mV CMC 28 µV 50 kHz až 100 kHz 4 mV až 10 mV CMC 35 µV 10 Hz až 40 Hz 10 mV až 15 mV CMC 6,0 µV 40 Hz až 100 Hz 10 mV až 15 mV CMC 5,7 µV 100 Hz až 2 kHz 10 mV až 15 mV CMC 3,6 µV 2 kHz až 10 kHz 10 mV až 15 mV CMC 5,6 µV 10 kHz až 30 kHz 10 mV až 15 mV CMC 13 µV 30 kHz až 100 kHz 10 mV až 15 mV CMC 31 µV 10 Hz až 40 Hz 15 mV až 20 mV CMC 6,7 µV 40 Hz až 100 Hz 15 mV až 20 mV CMC 6,3 µV 100 Hz až 2 kHz 15 mV až 20 mV CMC 4,2 µV 2 kHz až 10 kHz 15 mV až 20 mV CMC 6,2 µV 10 kHz až 30 kHz 15 mV až 20 mV CMC 11 µV 30 kHz až 100 kHz 15 mV až 20 mV CMC 23 µV 100 kHz až 300 kHz 15 mV až 20 mV CMC 82 µV 300 kHz až 1 MHz 15 mV až 20 mV CMC 0,19 mV 10 Hz až 40 Hz 20 mV až 30 mV CMC 0,034 % 40 Hz až 100 Hz 20 mV až 30 mV CMC 0,032 % 100 Hz až 2 kHz 20 mV až 30 mV CMC 0,021 % 2 kHz až 10 kHz 20 mV až 30 mV CMC 0,031 % 10 kHz až 30 kHz 20 mV až 30 mV CMC 0,053 % 30 kHz až 100 kHz 20 mV až 30 mV CMC 0,12 % 100 kHz až 300 kHz 20 mV až 30 mV CMC 0,41 % 300 kHz až 1 MHz 20 mV až 30 mV CMC 1,3 % 10 Hz až 40 Hz 30 mV až 50 mV CMC 0,027 % 40 Hz až 100 Hz 30 mV až 50 mV CMC 0,025 % 100 Hz až 2 kHz 30 mV až 50 mV CMC 0,018 % 2 kHz až 10 kHz 30 mV až 50 mV CMC 0,024 % 10 kHz až 30 kHz 30 mV až 50 mV CMC 0,047 % 30 kHz až 100 kHz 30 mV až 50 mV CMC 0,11 % 100 kHz až 300 kHz 30 mV až 50 mV CMC 0,39 % 300 kHz až 1 MHz 30 mV až 50 mV CMC 1,3 % 10 Hz až 40 Hz 50 mV až 100 mV CMC 0,022 % 40 Hz až 100 Hz 50 mV až 100 mV CMC 0,020 % 100 Hz až 2 kHz 50 mV až 100 mV CMC 0,015 % 2 kHz až 10 kHz 50 mV až 100 mV CMC 0,019 % 10 kHz až 30 kHz 50 mV až 100 mV CMC 0,044 % 30 kHz až 100 kHz 50 mV až 100 mV CMC 0,11 % 100 kHz až 300 kHz 50 mV až 100 mV CMC 0,38 % 300 kHz až 1 MHz 50 mV až 100 mV CMC 1,3 % 10 Hz až 40 Hz 100 mV až 150 mV CMC 0,018 % 40 Hz až 100 Hz 100 mV až 150 mV CMC 0,016 % 100 Hz až 2 kHz 100 mV až 150 mV CMC 0,013 % 2 kHz až 10 kHz 100 mV až 150 mV CMC 0,015 % 10 kHz až 30 kHz 100 mV až 150 mV CMC 0,039 % 30 kHz až 100 kHz 100 mV až 150 mV CMC 0,091 % 100 kHz až 300 kHz 100 mV až 150 mV CMC 0,45 % 300 kHz až 1 MHz 100 mV až 150 mV CMC 1,3 % 10 Hz až 40 Hz 150 mV až 200 mV CMC 0,016 % 40 Hz až 100 Hz 150 mV až 200 mV CMC 0,014 % 100 Hz až 2 kHz 150 mV až 200 mV CMC 0,012 % 2 kHz až 10 kHz 150 mV až 200 mV CMC 0,014 % 10 kHz až 30 kHz 150 mV až 200 mV CMC 0,036 % 30 kHz až 100 kHz 150 mV až 200 mV CMC 0,084 % 100 kHz až 300 kHz 150 mV až 200 mV CMC 0,43 % 300 kHz až 1 MHz 150 mV až 200 mV CMC 1,3 % 10 Hz až 40 Hz 200 mV až 300 mV CMC 0,021 % 40 Hz až 100 Hz 200 mV až 300 mV CMC 0,019 % 100 Hz až 2 kHz 200 mV až 300 mV CMC 0,017 % 2 kHz až 10 kHz 200 mV až 300 mV CMC 0,019 % 10 kHz až 30 kHz 200 mV až 300 mV CMC 0,041 % 30 kHz až 100 kHz 200 mV až 300 mV CMC 0,11 % 100 kHz až 300 kHz 200 mV až 300 mV CMC 0,41 % 300 kHz až 1 MHz 200 mV až 300 mV CMC 1,3 % 10 Hz až 40 Hz 300 mV až 500 mV CMC 0,018 % 40 Hz až 100 Hz 300 mV až 500 mV CMC 0,016 % 100 Hz až 2 kHz 300 mV až 500 mV CMC 0,014 % 2 kHz až 10 kHz 300 mV až 500 mV CMC 0,016 % 10 kHz až 30 kHz 300 mV až 500 mV CMC 0,034 % 30 kHz až 100 kHz 300 mV až 500 mV CMC 0,11 % 100 kHz až 300 kHz 300 mV až 500 mV CMC 0,39 % 300 kHz až 1 MHz 300 mV až 500 mV CMC 1,3 % 10 Hz až 40 Hz 500 mV až 1 V CMC 0,015 % 40 Hz až 100 Hz 500 mV až 1 V CMC 0,013 % 100 Hz až 2 kHz 500 mV až 1 V CMC 0,011 % 2 kHz až 10 kHz 500 mV až 1 V CMC 0,013 % 10 kHz až 30 kHz 500 mV až 1 V CMC 0,029 % 30 kHz až 100 kHz 500 mV až 1 V CMC 0,091 % 100 kHz až 300 kHz 500 mV až 1 V CMC 0,38 % 300 kHz až 1 MHz 500 mV až 1 V CMC 1,2 % 10 Hz až 40 Hz 1 V až 1,5 V CMC 0,013 % 40 Hz až 100 Hz 1 V až 1,5 V CMC 0,011 % 100 Hz až 2 kHz 1 V až 1,5 V CMC 0,0086 % 2 kHz až 10 kHz 1 V až 1,5 V CMC 0,011 % 10 kHz až 30 kHz 1 V až 1,5 V CMC 0,025 % 30 kHz až 100 kHz 1 V až 1,5 V CMC 0,071 % 100 kHz až 300 kHz 1 V až 1,5 V CMC 0,45 % 300 kHz až 1 MHz 1 V až 1,5 V CMC 1,3 % 10 Hz až 40 Hz 1,5 V až 2 V CMC 0,012 % 40 Hz až 100 Hz 1,5 V až 2 V CMC 0,0099 % 100 Hz až 2 kHz 1,5 V až 2 V CMC 0,0079 % 2 kHz až 10 kHz 1,5 V až 2 V CMC 0,010 % 10 kHz až 30 kHz 1,5 V až 2 V CMC 0,024 % 30 kHz až 100 kHz 1,5 V až 2 V CMC 0,065 % 100 kHz až 300 kHz 1,5 V až 2 V CMC 0,43 % 300 kHz až 1 MHz 1,5 V až 2 V CMC 1,3 % 10 Hz až 40 Hz 2 V až 3 V CMC 0,021 % 40 Hz až 100 Hz 2 V až 3 V CMC 0,019 % 100 Hz až 2 kHz 2 V až 3 V CMC 0,017 % 2 kHz až 10 kHz 2 V až 3 V CMC 0,019 % 10 kHz až 30 kHz 2 V až 3 V CMC 0,041 % 30 kHz až 100 kHz 2 V až 3 V CMC 0,11 % 100 kHz až 300 kHz 2 V až 3 V CMC 0,41 % 300 kHz až 1 MHz 2 V až 3 V CMC 1,3 % 10 Hz až 40 Hz 3 V až 5 V CMC 0,018 % 40 Hz až 100 Hz 3 V až 5 V CMC 0,016 % 100 Hz až 2 kHz 3 V až 5 V CMC 0,014 % 2 kHz až 10 kHz 3 V až 5 V CMC 0,016 % 10 kHz až 30 kHz 3 V až 5 V CMC 0,034 % 30 kHz až 100 kHz 3 V až 5 V CMC 0,11 % 100 kHz až 300 kHz 3 V až 5 V CMC 0,39 % 300 kHz až 1 MHz 3 V až 5 V CMC 1,3 % 10 Hz až 40 Hz 5 V až 10 V CMC 0,015 % 40 Hz až 100 Hz 5 V až 10 V CMC 0,013 % 100 Hz až 2 kHz 5 V až 10 V CMC 0,011 % 2 kHz až 10 kHz 5 V až 10 V CMC 0,013 % 10 kHz až 30 kHz 5 V až 10 V CMC 0,029 % 30 kHz až 100 kHz 5 V až 10 V CMC 0,091 % 100 kHz až 300 kHz 5 V až 10 V CMC 0,38 % 300 kHz až 1 MHz 5 V až 10 V CMC 1,2 % 10 Hz až 40 Hz 10 V až 15 V CMC 0,013 % 40 Hz až 100 Hz 10 V až 15 V CMC 0,011 % 100 Hz až 2 kHz 10 V až 15 V CMC 0,0086 % 2 kHz až 10 kHz 10 V až 15 V CMC 0,011 % 10 kHz až 30 kHz 10 V až 15 V CMC 0,025 % 30 kHz až 100 kHz 10 V až 15 V CMC 0,071 % 100 kHz až 300 kHz 10 V až 15 V CMC 0,51 % 300 kHz až 1 MHz 10 V až 15 V CMC 3,1 % 10 Hz až 40 Hz 15 V až 20 V CMC 0,012 % 40 Hz až 100 Hz 15 V až 20 V CMC 0,0099 % 100 Hz až 2 kHz 15 V až 20 V CMC 0,0079 % 2 kHz až 10 kHz 15 V až 20 V CMC 0,010 % 10 kHz až 30 kHz 15 V až 20 V CMC 0,024 % 30 kHz až 100 kHz 15 V až 20 V CMC 0,065 % 100 kHz až 300 kHz 15 V až 20 V CMC 0,44 % 300 kHz až 1 MHz 15 V až 20 V CMC 2,4 % 10 Hz až 40 Hz 20 V až 30 V CMC 0,021 % 40 Hz až 100 Hz 20 V až 30 V CMC 0,019 % 100 Hz až 2 kHz 20 V až 30 V CMC 0,017 % 2 kHz až 10 kHz 20 V až 30 V CMC 0,019 % 10 kHz až 30 kHz 20 V až 30 V CMC 0,041 % 30 kHz až 100 kHz 20 V až 30 V CMC 0,16 % 10 Hz až 40 Hz 30 V až 50 V CMC 0,018 % 40 Hz až 100 Hz 30 V až 50 V CMC 0,016 % 100 Hz až 2 kHz 30 V až 50 V CMC 0,014 % 2 kHz až 10 kHz 30 V až 50 V CMC 0,016 % 10 kHz až 30 kHz 30 V až 50 V CMC 0,034 % 30 kHz až 100 kHz 30 V až 50 V CMC 0,12 % 10 Hz až 40 Hz 50 V až 100 V CMC 0,015 % 40 Hz až 100 Hz 50 V až 100 V CMC 0,013 % 100 Hz až 2 kHz 50 V až 100 V CMC 0,011 % 2 kHz až 10 kHz 50 V až 100 V CMC 0,013 % 10 kHz až 30 kHz 50 V až 100 V CMC 0,029 % 30 kHz až 100 kHz 50 V až 100 V CMC 0,091 % 10 Hz až 40 Hz 100 V až 150 V CMC 0,013 % 40 Hz až 100 Hz 100 V až 150 V CMC 0,011 % 100 Hz až 2 kHz 100 V až 150 V CMC 0,0086 % 2 kHz až 10 kHz 100 V až 150 V CMC 0,011 % 10 kHz až 30 kHz 100 V až 150 V CMC 0,025 % 30 kHz až 100 kHz 100 V až 150 V CMC 0,071 % 10 Hz až 40 Hz 150 V až 200 V CMC 0,012 % 40 Hz až 100 Hz 150 V až 200 V CMC 0,0099 % 100 Hz až 2 kHz 150 V až 200 V CMC 0,0079 % 2 kHz až 10 kHz 150 V až 200 V CMC 0,010 % 10 kHz až 30 kHz 150 V až 200 V CMC 0,024 % 30 kHz až 100 kHz 150 V až 200 V CMC 0,065 % 40 Hz až 10 kHz 200 V až 300 V CMC 0,020 % 10 kHz až 30 kHz 200 V až 300 V CMC 0,041 % 30 kHz až 100 kHz 200 V až 300 V CMC 0,11 % 40 Hz až 10 kHz 300 V až 400 V CMC 0,017 % 10 kHz až 30 kHz 300 V až 400 V CMC 0,034 % 30 kHz až 100 kHz 300 V až 400 V CMC 0,077 % 40 Hz až 10 kHz 400 V až 500 V CMC 0,016 % 10 kHz až 20 kHz 400 V až 500 V CMC 0,035 % 20 kHz až 30 kHz 400 V až 500 V CMC 0,039 % 30 kHz až 100 kHz 400 V až 500 V CMC 0,063 % 40 Hz až 10 kHz 500 V až 600 V CMC 0,017 % 10 kHz až 20 kHz 500 V až 600 V CMC 0,040 % 20 kHz až 30 kHz 500 V až 600 V CMC 0,049 % 30 kHz až 100 kHz 500 V až 600 V CMC 0,065 % 40 Hz až 10 kHz 600 V až 700 V CMC 0,019 % 10 kHz až 20 kHz 600 V až 700 V CMC 0,049 % 20 kHz až 30 kHz 600 V až 700 V CMC 0,065 % 30 kHz až 100 kHz 600 V až 700 V CMC 0,077 % 40 Hz až 10 kHz 700 V až 800 V CMC 0,023 % 10 kHz až 20 kHz 700 V až 800 V CMC 0,061 % 20 kHz až 30 kHz 700 V až 800 V CMC 0,086 % 30 kHz až 100 kHz 700 V až 800 V CMC 0,095 % 40 Hz až 10 kHz 800 V až 900 V CMC 0,027 % 10 kHz až 20 kHz 800 V až 900 V CMC 0,076 % 20 kHz až 100 kHz 800 V až 900 V CMC 0,12 % 40 Hz až 10 kHz 900 V až 1000 V CMC 0,032 % 10 kHz až 20 kHz 900 V až 1000 V CMC 0,094 % 20 kHz až 100 kHz 900 V až 1000 V CMC 0,15 % 40 Hz až 10 kHz 1000 V až 1050 V CMC 0,034 % 10 kHz až 20 kHz 1000 V až 1050 V CMC 0,11 % 20 kHz až 100 kHz 1000 V až 1050 V CMC 0,16 % TP2, TP21 Napiecie przemienne / Zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 10 Hz do 40 Hz od 1,2 mV do 2 mV CMC 4,4 µV 40 Hz do 1 kHz od 1,2 mV do 2 mV CMC 2,1 µV 1 kHz do 20 kHz od 1,2 mV do 2 mV CMC 2,3 µV 20 kHz do 50 kHz od 1,2 mV do 2 mV CMC 3,8 µV 50 kHz do 100 kHz od 1,2 mV do 2 mV CMC 13 µV 10 Hz do 100 Hz od 2 mV do 4 mV CMC 4,6 µV 100 Hz do 2 kHz od 2 mV do 4 mV CMC 2,5 µV 2 kHz do 10 kHz od 2 mV do 4 mV CMC 4,5 µV 10 kHz do 50 kHz od 2 mV do 4 mV CMC 6,3 µV 30 kHz do 100 kHz od 2 mV do 4 mV CMC 23 µV 10 Hz do 40 Hz od 4 mV do 10 mV CMC 5,4 µV 40 Hz do 100 Hz od 4 mV do 10 mV CMC 5,2 µV 100 Hz do 2 kHz od 4 mV do 10 mV CMC 3,1 µV 2 kHz do 10 kHz od 4 mV do 10 mV CMC 5,1 µV 10 kHz do 30 kHz od 4 mV do 10 mV CMC 12 µV 30 kHz do 100 kHz od 4 mV do 10 mV CMC 28 µV 50 kHz do 100 kHz od 4 mV do 10 mV CMC 35 µV 10 Hz do 40 Hz od 10 mV do 15 mV CMC 6,0 µV 40 Hz do 100 Hz od 10 mV do 15 mV CMC 5,7 µV 100 Hz do 2 kHz od 10 mV do 15 mV CMC 3,6 µV 2 kHz do 10 kHz od 10 mV do 15 mV CMC 5,6 µV 10 kHz do 30 kHz od 10 mV do 15 mV CMC 13 µV 30 kHz do 100 kHz od 10 mV do 15 mV CMC 31 µV 10 Hz do 40 Hz od 15 mV do 20 mV CMC 6,7 µV 40 Hz do 100 Hz od 15 mV do 20 mV CMC 6,3 µV 100 Hz do 2 kHz od 15 mV do 20 mV CMC 4,2 µV 2 kHz do 10 kHz od 15 mV do 20 mV CMC 6,2 µV 10 kHz do 30 kHz od 15 mV do 20 mV CMC 11 µV 30 kHz do 100 kHz od 15 mV do 20 mV CMC 23 µV 100 kHz do 300 kHz od 15 mV do 20 mV CMC 82 µV 300 kHz do 1 MHz od 15 mV do 20 mV CMC 0,19 mV 10 Hz do 40 Hz od 20 mV do 30 mV CMC 0,034 % 40 Hz do 100 Hz od 20 mV do 30 mV CMC 0,032 % 100 Hz do 2 kHz od 20 mV do 30 mV CMC 0,021 % 2 kHz do 10 kHz od 20 mV do 30 mV CMC 0,031 % 10 kHz do 30 kHz od 20 mV do 30 mV CMC 0,053 % 30 kHz do 100 kHz od 20 mV do 30 mV CMC 0,12 % 100 kHz do 300 kHz od 20 mV do 30 mV CMC 0,41 % 300 kHz do 1 MHz od 20 mV do 30 mV CMC 1,3 % 10 Hz do 40 Hz od 30 mV do 50 mV CMC 0,027 % 40 Hz do 100 Hz od 30 mV do 50 mV CMC 0,025 % 100 Hz do 2 kHz od 30 mV do 50 mV CMC 0,018 % 2 kHz do 10 kHz od 30 mV do 50 mV CMC 0,024 % 10 kHz do 30 kHz od 30 mV do 50 mV CMC 0,047 % 30 kHz do 100 kHz od 30 mV do 50 mV CMC 0,11 % 100 kHz do 300 kHz od 30 mV do 50 mV CMC 0,39 % 300 kHz do 1 MHz od 30 mV do 50 mV CMC 1,3 % 10 Hz do 40 Hz od 50 mV do 100 mV CMC 0,022 % 40 Hz do 100 Hz od 50 mV do 100 mV CMC 0,020 % 100 Hz do 2 kHz od 50 mV do 100 mV CMC 0,015 % 2 kHz do 10 kHz od 50 mV do 100 mV CMC 0,019 % 10 kHz do 30 kHz od 50 mV do 100 mV CMC 0,044 % 30 kHz do 100 kHz od 50 mV do 100 mV CMC 0,11 % 100 kHz do 300 kHz od 50 mV do 100 mV CMC 0,38 % 300 kHz do 1 MHz od 50 mV do 100 mV CMC 1,3 % 10 Hz do 40 Hz od 100 mV do 150 mV CMC 0,018 % 40 Hz do 100 Hz od 100 mV do 150 mV CMC 0,016 % 100 Hz do 2 kHz od 100 mV do 150 mV CMC 0,013 % 2 kHz do 10 kHz od 100 mV do 150 mV CMC 0,015 % 10 kHz do 30 kHz od 100 mV do 150 mV CMC 0,039 % 30 kHz do 100 kHz od 100 mV do 150 mV CMC 0,091 % 100 kHz do 300 kHz od 100 mV do 150 mV CMC 0,45 % 300 kHz do 1 MHz od 100 mV do 150 mV CMC 1,3 % 10 Hz do 40 Hz od 150 mV do 200 mV CMC 0,016 % 40 Hz do 100 Hz od 150 mV do 200 mV CMC 0,014 % 100 Hz do 2 kHz od 150 mV do 200 mV CMC 0,012 % 2 kHz do 10 kHz od 150 mV do 200 mV CMC 0,014 % 10 kHz do 30 kHz od 150 mV do 200 mV CMC 0,036 % 30 kHz do 100 kHz od 150 mV do 200 mV CMC 0,084 % 100 kHz do 300 kHz od 150 mV do 200 mV CMC 0,43 % 300 kHz do 1 MHz od 150 mV do 200 mV CMC 1,3 % 10 Hz do 40 Hz od 200 mV do 300 mV CMC 0,021 % 40 Hz do 100 Hz od 200 mV do 300 mV CMC 0,019 % 100 Hz do 2 kHz od 200 mV do 300 mV CMC 0,017 % 2 kHz do 10 kHz od 200 mV do 300 mV CMC 0,019 % 10 kHz do 30 kHz od 200 mV do 300 mV CMC 0,041 % 30 kHz do 100 kHz od 200 mV do 300 mV CMC 0,11 % 100 kHz do 300 kHz od 200 mV do 300 mV CMC 0,41 % 300 kHz do 1 MHz od 200 mV do 300 mV CMC 1,3 % 10 Hz do 40 Hz od 300 mV do 500 mV CMC 0,018 % 40 Hz do 100 Hz od 300 mV do 500 mV CMC 0,016 % 100 Hz do 2 kHz od 300 mV do 500 mV CMC 0,014 % 2 kHz do 10 kHz od 300 mV do 500 mV CMC 0,016 % 10 kHz do 30 kHz od 300 mV do 500 mV CMC 0,034 % 30 kHz do 100 kHz od 300 mV do 500 mV CMC 0,11 % 100 kHz do 300 kHz od 300 mV do 500 mV CMC 0,39 % 300 kHz do 1 MHz od 300 mV do 500 mV CMC 1,3 % 10 Hz do 40 Hz od 500 mV do 1 V CMC 0,015 % 40 Hz do 100 Hz od 500 mV do 1 V CMC 0,013 % 100 Hz do 2 kHz od 500 mV do 1 V CMC 0,011 % 2 kHz do 10 kHz od 500 mV do 1 V CMC 0,013 % 10 kHz do 30 kHz od 500 mV do 1 V CMC 0,029 % 30 kHz do 100 kHz od 500 mV do 1 V CMC 0,091 % 100 kHz do 300 kHz od 500 mV do 1 V CMC 0,38 % 300 kHz do 1 MHz od 500 mV do 1 V CMC 1,2 % 10 Hz do 40 Hz od 1 V do 1,5 V CMC 0,013 % 40 Hz do 100 Hz od 1 V do 1,5 V CMC 0,011 % 100 Hz do 2 kHz od 1 V do 1,5 V CMC 0,0086 % 2 kHz do 10 kHz od 1 V do 1,5 V CMC 0,011 % 10 kHz do 30 kHz od 1 V do 1,5 V CMC 0,025 % 30 kHz do 100 kHz od 1 V do 1,5 V CMC 0,071 % 100 kHz do 300 kHz od 1 V do 1,5 V CMC 0,45 % 300 kHz do 1 MHz od 1 V do 1,5 V CMC 1,3 % 10 Hz do 40 Hz od 1,5 V do 2 V CMC 0,012 % 40 Hz do 100 Hz od 1,5 V do 2 V CMC 0,0099 % 100 Hz do 2 kHz od 1,5 V do 2 V CMC 0,0079 % 2 kHz do 10 kHz od 1,5 V do 2 V CMC 0,010 % 10 kHz do 30 kHz od 1,5 V do 2 V CMC 0,024 % 30 kHz do 100 kHz od 1,5 V do 2 V CMC 0,065 % 100 kHz do 300 kHz od 1,5 V do 2 V CMC 0,43 % 300 kHz do 1 MHz od 1,5 V do 2 V CMC 1,3 % 10 Hz do 40 Hz od 2 V do 3 V CMC 0,021 % 40 Hz do 100 Hz od 2 V do 3 V CMC 0,019 % 100 Hz do 2 kHz od 2 V do 3 V CMC 0,017 % 2 kHz do 10 kHz od 2 V do 3 V CMC 0,019 % 10 kHz do 30 kHz od 2 V do 3 V CMC 0,041 % 30 kHz do 100 kHz od 2 V do 3 V CMC 0,11 % 100 kHz do 300 kHz od 2 V do 3 V CMC 0,41 % 300 kHz do 1 MHz od 2 V do 3 V CMC 1,3 % 10 Hz do 40 Hz od 3 V do 5 V CMC 0,018 % 40 Hz do 100 Hz od 3 V do 5 V CMC 0,016 % 100 Hz do 2 kHz od 3 V do 5 V CMC 0,014 % 2 kHz do 10 kHz od 3 V do 5 V CMC 0,016 % 10 kHz do 30 kHz od 3 V do 5 V CMC 0,034 % 30 kHz do 100 kHz od 3 V do 5 V CMC 0,11 % 100 kHz do 300 kHz od 3 V do 5 V CMC 0,39 % 300 kHz do 1 MHz od 3 V do 5 V CMC 1,3 % 10 Hz do 40 Hz od 5 V do 10 V CMC 0,015 % 40 Hz do 100 Hz od 5 V do 10 V CMC 0,013 % 100 Hz do 2 kHz od 5 V do 10 V CMC 0,011 % 2 kHz do 10 kHz od 5 V do 10 V CMC 0,013 % 10 kHz do 30 kHz od 5 V do 10 V CMC 0,029 % 30 kHz do 100 kHz od 5 V do 10 V CMC 0,091 % 100 kHz do 300 kHz od 5 V do 10 V CMC 0,38 % 300 kHz do 1 MHz od 5 V do 10 V CMC 1,2 % 10 Hz do 40 Hz od 10 V do 15 V CMC 0,013 % 40 Hz do 100 Hz od 10 V do 15 V CMC 0,011 % 100 Hz do 2 kHz od 10 V do 15 V CMC 0,0086 % 2 kHz do 10 kHz od 10 V do 15 V CMC 0,011 % 10 kHz do 30 kHz od 10 V do 15 V CMC 0,025 % 30 kHz do 100 kHz od 10 V do 15 V CMC 0,071 % 100 kHz do 300 kHz od 10 V do 15 V CMC 0,51 % 300 kHz do 1 MHz od 10 V do 15 V CMC 3,1 % 10 Hz do 40 Hz od 15 V do 20 V CMC 0,012 % 40 Hz do 100 Hz od 15 V do 20 V CMC 0,0099 % 100 Hz do 2 kHz od 15 V do 20 V CMC 0,0079 % 2 kHz do 10 kHz od 15 V do 20 V CMC 0,010 % 10 kHz do 30 kHz od 15 V do 20 V CMC 0,024 % 30 kHz do 100 kHz od 15 V do 20 V CMC 0,065 % 100 kHz do 300 kHz od 15 V do 20 V CMC 0,44 % 300 kHz do 1 MHz od 15 V do 20 V CMC 2,4 % 10 Hz do 40 Hz od 20 V do 30 V CMC 0,021 % 40 Hz do 100 Hz od 20 V do 30 V CMC 0,019 % 100 Hz do 2 kHz od 20 V do 30 V CMC 0,017 % 2 kHz do 10 kHz od 20 V do 30 V CMC 0,019 % 10 kHz do 30 kHz od 20 V do 30 V CMC 0,041 % 30 kHz do 100 kHz od 20 V do 30 V CMC 0,16 % 10 Hz do 40 Hz od 30 V do 50 V CMC 0,018 % 40 Hz do 100 Hz od 30 V do 50 V CMC 0,016 % 100 Hz do 2 kHz od 30 V do 50 V CMC 0,014 % 2 kHz do 10 kHz od 30 V do 50 V CMC 0,016 % 10 kHz do 30 kHz od 30 V do 50 V CMC 0,034 % 30 kHz do 100 kHz od 30 V do 50 V CMC 0,12 % 10 Hz do 40 Hz od 50 V do 100 V CMC 0,015 % 40 Hz do 100 Hz od 50 V do 100 V CMC 0,013 % 100 Hz do 2 kHz od 50 V do 100 V CMC 0,011 % 2 kHz do 10 kHz od 50 V do 100 V CMC 0,013 % 10 kHz do 30 kHz od 50 V do 100 V CMC 0,029 % 30 kHz do 100 kHz od 50 V do 100 V CMC 0,091 % 10 Hz do 40 Hz od 100 V do 150 V CMC 0,013 % 40 Hz do 100 Hz od 100 V do 150 V CMC 0,011 % 100 Hz do 2 kHz od 100 V do 150 V CMC 0,0086 % 2 kHz do 10 kHz od 100 V do 150 V CMC 0,011 % 10 kHz do 30 kHz od 100 V do 150 V CMC 0,025 % 30 kHz do 100 kHz od 100 V do 150 V CMC 0,071 % 10 Hz do 40 Hz od 150 V do 200 V CMC 0,012 % 40 Hz do 100 Hz od 150 V do 200 V CMC 0,0099 % 100 Hz do 2 kHz od 150 V do 200 V CMC 0,0079 % 2 kHz do 10 kHz od 150 V do 200 V CMC 0,010 % 10 kHz do 30 kHz od 150 V do 200 V CMC 0,024 % 30 kHz do 100 kHz od 150 V do 200 V CMC 0,065 % 40 Hz do 10 kHz od 200 V do 300 V CMC 0,020 % 10 kHz do 30 kHz od 200 V do 300 V CMC 0,041 % 30 kHz do 100 kHz od 200 V do 300 V CMC 0,11 % 40 Hz do 10 kHz od 300 V do 400 V CMC 0,017 % 10 kHz do 30 kHz od 300 V do 400 V CMC 0,034 % 30 kHz do 100 kHz od 300 V do 400 V CMC 0,077 % 40 Hz do 10 kHz od 400 V do 500 V CMC 0,016 % 10 kHz do 20 kHz od 400 V do 500 V CMC 0,035 % 20 kHz do 30 kHz od 400 V do 500 V CMC 0,039 % 30 kHz do 100 kHz od 400 V do 500 V CMC 0,063 % 40 Hz do 10 kHz od 500 V do 600 V CMC 0,017 % 10 kHz do 20 kHz od 500 V do 600 V CMC 0,040 % 20 kHz do 30 kHz od 500 V do 600 V CMC 0,049 % 30 kHz do 100 kHz od 500 V do 600 V CMC 0,065 % 40 Hz do 10 kHz od 600 V do 700 V CMC 0,019 % 10 kHz do 20 kHz od 600 V do 700 V CMC 0,049 % 20 kHz do 30 kHz od 600 V do 700 V CMC 0,065 % 30 kHz do 100 kHz od 600 V do 700 V CMC 0,077 % 40 Hz do 10 kHz od 700 V do 800 V CMC 0,023 % 10 kHz do 20 kHz od 700 V do 800 V CMC 0,061 % 20 kHz do 30 kHz od 700 V do 800 V CMC 0,086 % 30 kHz do 100 kHz od 700 V do 800 V CMC 0,095 % 40 Hz do 10 kHz od 800 V do 900 V CMC 0,027 % 10 kHz do 20 kHz od 800 V do 900 V CMC 0,076 % 20 kHz do 100 kHz od 800 V do 900 V CMC 0,12 % 40 Hz do 10 kHz od 900 V do 1000 V CMC 0,032 % 10 kHz do 20 kHz od 900 V do 1000 V CMC 0,094 % 20 kHz do 100 kHz od 900 V do 1000 V CMC 0,15 % 40 Hz do 10 kHz od 1000 V do 1050 V CMC 0,034 % 10 kHz do 20 kHz od 1000 V do 1050 V CMC 0,11 % 20 kHz do 100 kHz od 1000 V do 1050 V CMC 0,16 % Stridave napeti / Zdroje stridaveho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 10 Hz az 40 Hz 1,2 mV az 2 mV CMC 4,4 µV 40 Hz az 1 kHz 1,2 mV az 2 mV CMC 2,1 µV 1 kHz az 20 kHz 1,2 mV az 2 mV CMC 2,3 µV 20 kHz az 50 kHz 1,2 mV az 2 mV CMC 3,8 µV 50 kHz az 100 kHz 1,2 mV az 2 mV CMC 13 µV 10 Hz az 100 Hz 2 mV az 4 mV CMC 4,6 µV 100 Hz az 2 kHz 2 mV az 4 mV CMC 2,5 µV 2 kHz az 10 kHz 2 mV az 4 mV CMC 4,5 µV 10 kHz az 50 kHz 2 mV az 4 mV CMC 6,3 µV 30 kHz az 100 kHz 2 mV az 4 mV CMC 23 µV 10 Hz az 40 Hz 4 mV az 10 mV CMC 5,4 µV 40 Hz az 100 Hz 4 mV az 10 mV CMC 5,2 µV 100 Hz az 2 kHz 4 mV az 10 mV CMC 3,1 µV 2 kHz az 10 kHz 4 mV az 10 mV CMC 5,1 µV 10 kHz az 30 kHz 4 mV az 10 mV CMC 12 µV 30 kHz az 100 kHz 4 mV az 10 mV CMC 28 µV 50 kHz az 100 kHz 4 mV az 10 mV CMC 35 µV 10 Hz az 40 Hz 10 mV az 15 mV CMC 6,0 µV 40 Hz az 100 Hz 10 mV az 15 mV CMC 5,7 µV 100 Hz az 2 kHz 10 mV az 15 mV CMC 3,6 µV 2 kHz az 10 kHz 10 mV az 15 mV CMC 5,6 µV 10 kHz az 30 kHz 10 mV az 15 mV CMC 13 µV 30 kHz az 100 kHz 10 mV az 15 mV CMC 31 µV 10 Hz az 40 Hz 15 mV az 20 mV CMC 6,7 µV 40 Hz az 100 Hz 15 mV az 20 mV CMC 6,3 µV 100 Hz az 2 kHz 15 mV az 20 mV CMC 4,2 µV 2 kHz az 10 kHz 15 mV az 20 mV CMC 6,2 µV 10 kHz az 30 kHz 15 mV az 20 mV CMC 11 µV 30 kHz az 100 kHz 15 mV az 20 mV CMC 23 µV 100 kHz az 300 kHz 15 mV az 20 mV CMC 82 µV 300 kHz az 1 MHz 15 mV az 20 mV CMC 0,19 mV 10 Hz az 40 Hz 20 mV az 30 mV CMC 0,034 % 40 Hz az 100 Hz 20 mV az 30 mV CMC 0,032 % 100 Hz az 2 kHz 20 mV az 30 mV CMC 0,021 % 2 kHz az 10 kHz 20 mV az 30 mV CMC 0,031 % 10 kHz az 30 kHz 20 mV az 30 mV CMC 0,053 % 30 kHz az 100 kHz 20 mV az 30 mV CMC 0,12 % 100 kHz az 300 kHz 20 mV az 30 mV CMC 0,41 % 300 kHz az 1 MHz 20 mV az 30 mV CMC 1,3 % 10 Hz az 40 Hz 30 mV az 50 mV CMC 0,027 % 40 Hz az 100 Hz 30 mV az 50 mV CMC 0,025 % 100 Hz az 2 kHz 30 mV az 50 mV CMC 0,018 % 2 kHz az 10 kHz 30 mV az 50 mV CMC 0,024 % 10 kHz az 30 kHz 30 mV az 50 mV CMC 0,047 % 30 kHz az 100 kHz 30 mV az 50 mV CMC 0,11 % 100 kHz az 300 kHz 30 mV az 50 mV CMC 0,39 % 300 kHz az 1 MHz 30 mV az 50 mV CMC 1,3 % 10 Hz az 40 Hz 50 mV az 100 mV CMC 0,022 % 40 Hz az 100 Hz 50 mV az 100 mV CMC 0,020 % 100 Hz az 2 kHz 50 mV az 100 mV CMC 0,015 % 2 kHz az 10 kHz 50 mV az 100 mV CMC 0,019 % 10 kHz az 30 kHz 50 mV az 100 mV CMC 0,044 % 30 kHz az 100 kHz 50 mV az 100 mV CMC 0,11 % 100 kHz az 300 kHz 50 mV az 100 mV CMC 0,38 % 300 kHz az 1 MHz 50 mV az 100 mV CMC 1,3 % 10 Hz az 40 Hz 100 mV az 150 mV CMC 0,018 % 40 Hz az 100 Hz 100 mV az 150 mV CMC 0,016 % 100 Hz az 2 kHz 100 mV az 150 mV CMC 0,013 % 2 kHz az 10 kHz 100 mV az 150 mV CMC 0,015 % 10 kHz az 30 kHz 100 mV az 150 mV CMC 0,039 % 30 kHz az 100 kHz 100 mV az 150 mV CMC 0,091 % 100 kHz az 300 kHz 100 mV az 150 mV CMC 0,45 % 300 kHz az 1 MHz 100 mV az 150 mV CMC 1,3 % 10 Hz az 40 Hz 150 mV az 200 mV CMC 0,016 % 40 Hz az 100 Hz 150 mV az 200 mV CMC 0,014 % 100 Hz az 2 kHz 150 mV az 200 mV CMC 0,012 % 2 kHz az 10 kHz 150 mV az 200 mV CMC 0,014 % 10 kHz az 30 kHz 150 mV az 200 mV CMC 0,036 % 30 kHz az 100 kHz 150 mV az 200 mV CMC 0,084 % 100 kHz az 300 kHz 150 mV az 200 mV CMC 0,43 % 300 kHz az 1 MHz 150 mV az 200 mV CMC 1,3 % 10 Hz az 40 Hz 200 mV az 300 mV CMC 0,021 % 40 Hz az 100 Hz 200 mV az 300 mV CMC 0,019 % 100 Hz az 2 kHz 200 mV az 300 mV CMC 0,017 % 2 kHz az 10 kHz 200 mV az 300 mV CMC 0,019 % 10 kHz az 30 kHz 200 mV az 300 mV CMC 0,041 % 30 kHz az 100 kHz 200 mV az 300 mV CMC 0,11 % 100 kHz az 300 kHz 200 mV az 300 mV CMC 0,41 % 300 kHz az 1 MHz 200 mV az 300 mV CMC 1,3 % 10 Hz az 40 Hz 300 mV az 500 mV CMC 0,018 % 40 Hz az 100 Hz 300 mV az 500 mV CMC 0,016 % 100 Hz az 2 kHz 300 mV az 500 mV CMC 0,014 % 2 kHz az 10 kHz 300 mV az 500 mV CMC 0,016 % 10 kHz az 30 kHz 300 mV az 500 mV CMC 0,034 % 30 kHz az 100 kHz 300 mV az 500 mV CMC 0,11 % 100 kHz az 300 kHz 300 mV az 500 mV CMC 0,39 % 300 kHz az 1 MHz 300 mV az 500 mV CMC 1,3 % 10 Hz az 40 Hz 500 mV az 1 V CMC 0,015 % 40 Hz az 100 Hz 500 mV az 1 V CMC 0,013 % 100 Hz az 2 kHz 500 mV az 1 V CMC 0,011 % 2 kHz az 10 kHz 500 mV az 1 V CMC 0,013 % 10 kHz az 30 kHz 500 mV az 1 V CMC 0,029 % 30 kHz az 100 kHz 500 mV az 1 V CMC 0,091 % 100 kHz az 300 kHz 500 mV az 1 V CMC 0,38 % 300 kHz az 1 MHz 500 mV az 1 V CMC 1,2 % 10 Hz az 40 Hz 1 V az 1,5 V CMC 0,013 % 40 Hz az 100 Hz 1 V az 1,5 V CMC 0,011 % 100 Hz az 2 kHz 1 V az 1,5 V CMC 0,0086 % 2 kHz az 10 kHz 1 V az 1,5 V CMC 0,011 % 10 kHz az 30 kHz 1 V az 1,5 V CMC 0,025 % 30 kHz az 100 kHz 1 V az 1,5 V CMC 0,071 % 100 kHz az 300 kHz 1 V az 1,5 V CMC 0,45 % 300 kHz az 1 MHz 1 V az 1,5 V CMC 1,3 % 10 Hz az 40 Hz 1,5 V az 2 V CMC 0,012 % 40 Hz az 100 Hz 1,5 V az 2 V CMC 0,0099 % 100 Hz az 2 kHz 1,5 V az 2 V CMC 0,0079 % 2 kHz az 10 kHz 1,5 V az 2 V CMC 0,010 % 10 kHz az 30 kHz 1,5 V az 2 V CMC 0,024 % 30 kHz az 100 kHz 1,5 V az 2 V CMC 0,065 % 100 kHz az 300 kHz 1,5 V az 2 V CMC 0,43 % 300 kHz az 1 MHz 1,5 V az 2 V CMC 1,3 % 10 Hz az 40 Hz 2 V az 3 V CMC 0,021 % 40 Hz az 100 Hz 2 V az 3 V CMC 0,019 % 100 Hz az 2 kHz 2 V az 3 V CMC 0,017 % 2 kHz az 10 kHz 2 V az 3 V CMC 0,019 % 10 kHz az 30 kHz 2 V az 3 V CMC 0,041 % 30 kHz az 100 kHz 2 V az 3 V CMC 0,11 % 100 kHz az 300 kHz 2 V az 3 V CMC 0,41 % 300 kHz az 1 MHz 2 V az 3 V CMC 1,3 % 10 Hz az 40 Hz 3 V az 5 V CMC 0,018 % 40 Hz az 100 Hz 3 V az 5 V CMC 0,016 % 100 Hz az 2 kHz 3 V az 5 V CMC 0,014 % 2 kHz az 10 kHz 3 V az 5 V CMC 0,016 % 10 kHz az 30 kHz 3 V az 5 V CMC 0,034 % 30 kHz az 100 kHz 3 V az 5 V CMC 0,11 % 100 kHz az 300 kHz 3 V az 5 V CMC 0,39 % 300 kHz az 1 MHz 3 V az 5 V CMC 1,3 % 10 Hz az 40 Hz 5 V az 10 V CMC 0,015 % 40 Hz az 100 Hz 5 V az 10 V CMC 0,013 % 100 Hz az 2 kHz 5 V az 10 V CMC 0,011 % 2 kHz az 10 kHz 5 V az 10 V CMC 0,013 % 10 kHz az 30 kHz 5 V az 10 V CMC 0,029 % 30 kHz az 100 kHz 5 V az 10 V CMC 0,091 % 100 kHz az 300 kHz 5 V az 10 V CMC 0,38 % 300 kHz az 1 MHz 5 V az 10 V CMC 1,2 % 10 Hz az 40 Hz 10 V az 15 V CMC 0,013 % 40 Hz az 100 Hz 10 V az 15 V CMC 0,011 % 100 Hz az 2 kHz 10 V az 15 V CMC 0,0086 % 2 kHz az 10 kHz 10 V az 15 V CMC 0,011 % 10 kHz az 30 kHz 10 V az 15 V CMC 0,025 % 30 kHz az 100 kHz 10 V az 15 V CMC 0,071 % 100 kHz az 300 kHz 10 V az 15 V CMC 0,51 % 300 kHz az 1 MHz 10 V az 15 V CMC 3,1 % 10 Hz az 40 Hz 15 V az 20 V CMC 0,012 % 40 Hz az 100 Hz 15 V az 20 V CMC 0,0099 % 100 Hz az 2 kHz 15 V az 20 V CMC 0,0079 % 2 kHz az 10 kHz 15 V az 20 V CMC 0,010 % 10 kHz az 30 kHz 15 V az 20 V CMC 0,024 % 30 kHz az 100 kHz 15 V az 20 V CMC 0,065 % 100 kHz az 300 kHz 15 V az 20 V CMC 0,44 % 300 kHz az 1 MHz 15 V az 20 V CMC 2,4 % 10 Hz az 40 Hz 20 V az 30 V CMC 0,021 % 40 Hz az 100 Hz 20 V az 30 V CMC 0,019 % 100 Hz az 2 kHz 20 V az 30 V CMC 0,017 % 2 kHz az 10 kHz 20 V az 30 V CMC 0,019 % 10 kHz az 30 kHz 20 V az 30 V CMC 0,041 % 30 kHz az 100 kHz 20 V az 30 V CMC 0,16 % 10 Hz az 40 Hz 30 V az 50 V CMC 0,018 % 40 Hz az 100 Hz 30 V az 50 V CMC 0,016 % 100 Hz az 2 kHz 30 V az 50 V CMC 0,014 % 2 kHz az 10 kHz 30 V az 50 V CMC 0,016 % 10 kHz az 30 kHz 30 V az 50 V CMC 0,034 % 30 kHz az 100 kHz 30 V az 50 V CMC 0,12 % 10 Hz az 40 Hz 50 V az 100 V CMC 0,015 % 40 Hz az 100 Hz 50 V az 100 V CMC 0,013 % 100 Hz az 2 kHz 50 V az 100 V CMC 0,011 % 2 kHz az 10 kHz 50 V az 100 V CMC 0,013 % 10 kHz az 30 kHz 50 V az 100 V CMC 0,029 % 30 kHz az 100 kHz 50 V az 100 V CMC 0,091 % 10 Hz az 40 Hz 100 V az 150 V CMC 0,013 % 40 Hz az 100 Hz 100 V az 150 V CMC 0,011 % 100 Hz az 2 kHz 100 V az 150 V CMC 0,0086 % 2 kHz az 10 kHz 100 V az 150 V CMC 0,011 % 10 kHz az 30 kHz 100 V az 150 V CMC 0,025 % 30 kHz az 100 kHz 100 V az 150 V CMC 0,071 % 10 Hz az 40 Hz 150 V az 200 V CMC 0,012 % 40 Hz az 100 Hz 150 V az 200 V CMC 0,0099 % 100 Hz az 2 kHz 150 V az 200 V CMC 0,0079 % 2 kHz az 10 kHz 150 V az 200 V CMC 0,010 % 10 kHz az 30 kHz 150 V az 200 V CMC 0,024 % 30 kHz az 100 kHz 150 V az 200 V CMC 0,065 % 40 Hz az 10 kHz 200 V az 300 V CMC 0,020 % 10 kHz az 30 kHz 200 V az 300 V CMC 0,041 % 30 kHz az 100 kHz 200 V az 300 V CMC 0,11 % 40 Hz az 10 kHz 300 V az 400 V CMC 0,017 % 10 kHz az 30 kHz 300 V az 400 V CMC 0,034 % 30 kHz az 100 kHz 300 V az 400 V CMC 0,077 % 40 Hz az 10 kHz 400 V az 500 V CMC 0,016 % 10 kHz az 20 kHz 400 V az 500 V CMC 0,035 % 20 kHz az 30 kHz 400 V az 500 V CMC 0,039 % 30 kHz az 100 kHz 400 V az 500 V CMC 0,063 % 40 Hz az 10 kHz 500 V az 600 V CMC 0,017 % 10 kHz az 20 kHz 500 V az 600 V CMC 0,040 % 20 kHz az 30 kHz 500 V az 600 V CMC 0,049 % 30 kHz az 100 kHz 500 V az 600 V CMC 0,065 % 40 Hz az 10 kHz 600 V az 700 V CMC 0,019 % 10 kHz az 20 kHz 600 V az 700 V CMC 0,049 % 20 kHz az 30 kHz 600 V az 700 V CMC 0,065 % 30 kHz az 100 kHz 600 V az 700 V CMC 0,077 % 40 Hz az 10 kHz 700 V az 800 V CMC 0,023 % 10 kHz az 20 kHz 700 V az 800 V CMC 0,061 % 20 kHz az 30 kHz 700 V az 800 V CMC 0,086 % 30 kHz az 100 kHz 700 V az 800 V CMC 0,095 % 40 Hz az 10 kHz 800 V az 900 V CMC 0,027 % 10 kHz az 20 kHz 800 V az 900 V CMC 0,076 % 20 kHz az 100 kHz 800 V az 900 V CMC 0,12 % 40 Hz az 10 kHz 900 V az 1000 V CMC 0,032 % 10 kHz az 20 kHz 900 V az 1000 V CMC 0,094 % 20 kHz az 100 kHz 900 V az 1000 V CMC 0,15 % 40 Hz az 10 kHz 1000 V az 1050 V CMC 0,034 % 10 kHz az 20 kHz 1000 V az 1050 V CMC 0,11 % 20 kHz az 100 kHz 1000 V az 1050 V CMC 0,16 % TP2, TP21","search_en":"AC voltage / AC voltage sources Calibration – electrical quantities Direct measurement using a multimeter 10 Hz to 40 Hz 1,2 mV to 2 mV CMC 4,4 µV 40 Hz to 1 kHz 1,2 mV to 2 mV CMC 2,1 µV 1 kHz to 20 kHz 1,2 mV to 2 mV CMC 2,3 µV 20 kHz to 50 kHz 1,2 mV to 2 mV CMC 3,8 µV 50 kHz to 100 kHz 1,2 mV to 2 mV CMC 13 µV 10 Hz to 100 Hz 2 mV to 4 mV CMC 4,6 µV 100 Hz to 2 kHz 2 mV to 4 mV CMC 2,5 µV 2 kHz to 10 kHz 2 mV to 4 mV CMC 4,5 µV 10 kHz to 50 kHz 2 mV to 4 mV CMC 6,3 µV 30 kHz to 100 kHz 2 mV to 4 mV CMC 23 µV 10 Hz to 40 Hz 4 mV to 10 mV CMC 5,4 µV 40 Hz to 100 Hz 4 mV to 10 mV CMC 5,2 µV 100 Hz to 2 kHz 4 mV to 10 mV CMC 3,1 µV 2 kHz to 10 kHz 4 mV to 10 mV CMC 5,1 µV 10 kHz to 30 kHz 4 mV to 10 mV CMC 12 µV 30 kHz to 100 kHz 4 mV to 10 mV CMC 28 µV 50 kHz to 100 kHz 4 mV to 10 mV CMC 35 µV 10 Hz to 40 Hz 10 mV to 15 mV CMC 6,0 µV 40 Hz to 100 Hz 10 mV to 15 mV CMC 5,7 µV 100 Hz to 2 kHz 10 mV to 15 mV CMC 3,6 µV 2 kHz to 10 kHz 10 mV to 15 mV CMC 5,6 µV 10 kHz to 30 kHz 10 mV to 15 mV CMC 13 µV 30 kHz to 100 kHz 10 mV to 15 mV CMC 31 µV 10 Hz to 40 Hz 15 mV to 20 mV CMC 6,7 µV 40 Hz to 100 Hz 15 mV to 20 mV CMC 6,3 µV 100 Hz to 2 kHz 15 mV to 20 mV CMC 4,2 µV 2 kHz to 10 kHz 15 mV to 20 mV CMC 6,2 µV 10 kHz to 30 kHz 15 mV to 20 mV CMC 11 µV 30 kHz to 100 kHz 15 mV to 20 mV CMC 23 µV 100 kHz to 300 kHz 15 mV to 20 mV CMC 82 µV 300 kHz to 1 MHz 15 mV to 20 mV CMC 0,19 mV 10 Hz to 40 Hz 20 mV to 30 mV CMC 0,034 % 40 Hz to 100 Hz 20 mV to 30 mV CMC 0,032 % 100 Hz to 2 kHz 20 mV to 30 mV CMC 0,021 % 2 kHz to 10 kHz 20 mV to 30 mV CMC 0,031 % 10 kHz to 30 kHz 20 mV to 30 mV CMC 0,053 % 30 kHz to 100 kHz 20 mV to 30 mV CMC 0,12 % 100 kHz to 300 kHz 20 mV to 30 mV CMC 0,41 % 300 kHz to 1 MHz 20 mV to 30 mV CMC 1,3 % 10 Hz to 40 Hz 30 mV to 50 mV CMC 0,027 % 40 Hz to 100 Hz 30 mV to 50 mV CMC 0,025 % 100 Hz to 2 kHz 30 mV to 50 mV CMC 0,018 % 2 kHz to 10 kHz 30 mV to 50 mV CMC 0,024 % 10 kHz to 30 kHz 30 mV to 50 mV CMC 0,047 % 30 kHz to 100 kHz 30 mV to 50 mV CMC 0,11 % 100 kHz to 300 kHz 30 mV to 50 mV CMC 0,39 % 300 kHz to 1 MHz 30 mV to 50 mV CMC 1,3 % 10 Hz to 40 Hz 50 mV to 100 mV CMC 0,022 % 40 Hz to 100 Hz 50 mV to 100 mV CMC 0,020 % 100 Hz to 2 kHz 50 mV to 100 mV CMC 0,015 % 2 kHz to 10 kHz 50 mV to 100 mV CMC 0,019 % 10 kHz to 30 kHz 50 mV to 100 mV CMC 0,044 % 30 kHz to 100 kHz 50 mV to 100 mV CMC 0,11 % 100 kHz to 300 kHz 50 mV to 100 mV CMC 0,38 % 300 kHz to 1 MHz 50 mV to 100 mV CMC 1,3 % 10 Hz to 40 Hz 100 mV to 150 mV CMC 0,018 % 40 Hz to 100 Hz 100 mV to 150 mV CMC 0,016 % 100 Hz to 2 kHz 100 mV to 150 mV CMC 0,013 % 2 kHz to 10 kHz 100 mV to 150 mV CMC 0,015 % 10 kHz to 30 kHz 100 mV to 150 mV CMC 0,039 % 30 kHz to 100 kHz 100 mV to 150 mV CMC 0,091 % 100 kHz to 300 kHz 100 mV to 150 mV CMC 0,45 % 300 kHz to 1 MHz 100 mV to 150 mV CMC 1,3 % 10 Hz to 40 Hz 150 mV to 200 mV CMC 0,016 % 40 Hz to 100 Hz 150 mV to 200 mV CMC 0,014 % 100 Hz to 2 kHz 150 mV to 200 mV CMC 0,012 % 2 kHz to 10 kHz 150 mV to 200 mV CMC 0,014 % 10 kHz to 30 kHz 150 mV to 200 mV CMC 0,036 % 30 kHz to 100 kHz 150 mV to 200 mV CMC 0,084 % 100 kHz to 300 kHz 150 mV to 200 mV CMC 0,43 % 300 kHz to 1 MHz 150 mV to 200 mV CMC 1,3 % 10 Hz to 40 Hz 200 mV to 300 mV CMC 0,021 % 40 Hz to 100 Hz 200 mV to 300 mV CMC 0,019 % 100 Hz to 2 kHz 200 mV to 300 mV CMC 0,017 % 2 kHz to 10 kHz 200 mV to 300 mV CMC 0,019 % 10 kHz to 30 kHz 200 mV to 300 mV CMC 0,041 % 30 kHz to 100 kHz 200 mV to 300 mV CMC 0,11 % 100 kHz to 300 kHz 200 mV to 300 mV CMC 0,41 % 300 kHz to 1 MHz 200 mV to 300 mV CMC 1,3 % 10 Hz to 40 Hz 300 mV to 500 mV CMC 0,018 % 40 Hz to 100 Hz 300 mV to 500 mV CMC 0,016 % 100 Hz to 2 kHz 300 mV to 500 mV CMC 0,014 % 2 kHz to 10 kHz 300 mV to 500 mV CMC 0,016 % 10 kHz to 30 kHz 300 mV to 500 mV CMC 0,034 % 30 kHz to 100 kHz 300 mV to 500 mV CMC 0,11 % 100 kHz to 300 kHz 300 mV to 500 mV CMC 0,39 % 300 kHz to 1 MHz 300 mV to 500 mV CMC 1,3 % 10 Hz to 40 Hz 500 mV to 1 V CMC 0,015 % 40 Hz to 100 Hz 500 mV to 1 V CMC 0,013 % 100 Hz to 2 kHz 500 mV to 1 V CMC 0,011 % 2 kHz to 10 kHz 500 mV to 1 V CMC 0,013 % 10 kHz to 30 kHz 500 mV to 1 V CMC 0,029 % 30 kHz to 100 kHz 500 mV to 1 V CMC 0,091 % 100 kHz to 300 kHz 500 mV to 1 V CMC 0,38 % 300 kHz to 1 MHz 500 mV to 1 V CMC 1,2 % 10 Hz to 40 Hz 1 V to 1,5 V CMC 0,013 % 40 Hz to 100 Hz 1 V to 1,5 V CMC 0,011 % 100 Hz to 2 kHz 1 V to 1,5 V CMC 0,0086 % 2 kHz to 10 kHz 1 V to 1,5 V CMC 0,011 % 10 kHz to 30 kHz 1 V to 1,5 V CMC 0,025 % 30 kHz to 100 kHz 1 V to 1,5 V CMC 0,071 % 100 kHz to 300 kHz 1 V to 1,5 V CMC 0,45 % 300 kHz to 1 MHz 1 V to 1,5 V CMC 1,3 % 10 Hz to 40 Hz 1,5 V to 2 V CMC 0,012 % 40 Hz to 100 Hz 1,5 V to 2 V CMC 0,0099 % 100 Hz to 2 kHz 1,5 V to 2 V CMC 0,0079 % 2 kHz to 10 kHz 1,5 V to 2 V CMC 0,010 % 10 kHz to 30 kHz 1,5 V to 2 V CMC 0,024 % 30 kHz to 100 kHz 1,5 V to 2 V CMC 0,065 % 100 kHz to 300 kHz 1,5 V to 2 V CMC 0,43 % 300 kHz to 1 MHz 1,5 V to 2 V CMC 1,3 % 10 Hz to 40 Hz 2 V to 3 V CMC 0,021 % 40 Hz to 100 Hz 2 V to 3 V CMC 0,019 % 100 Hz to 2 kHz 2 V to 3 V CMC 0,017 % 2 kHz to 10 kHz 2 V to 3 V CMC 0,019 % 10 kHz to 30 kHz 2 V to 3 V CMC 0,041 % 30 kHz to 100 kHz 2 V to 3 V CMC 0,11 % 100 kHz to 300 kHz 2 V to 3 V CMC 0,41 % 300 kHz to 1 MHz 2 V to 3 V CMC 1,3 % 10 Hz to 40 Hz 3 V to 5 V CMC 0,018 % 40 Hz to 100 Hz 3 V to 5 V CMC 0,016 % 100 Hz to 2 kHz 3 V to 5 V CMC 0,014 % 2 kHz to 10 kHz 3 V to 5 V CMC 0,016 % 10 kHz to 30 kHz 3 V to 5 V CMC 0,034 % 30 kHz to 100 kHz 3 V to 5 V CMC 0,11 % 100 kHz to 300 kHz 3 V to 5 V CMC 0,39 % 300 kHz to 1 MHz 3 V to 5 V CMC 1,3 % 10 Hz to 40 Hz 5 V to 10 V CMC 0,015 % 40 Hz to 100 Hz 5 V to 10 V CMC 0,013 % 100 Hz to 2 kHz 5 V to 10 V CMC 0,011 % 2 kHz to 10 kHz 5 V to 10 V CMC 0,013 % 10 kHz to 30 kHz 5 V to 10 V CMC 0,029 % 30 kHz to 100 kHz 5 V to 10 V CMC 0,091 % 100 kHz to 300 kHz 5 V to 10 V CMC 0,38 % 300 kHz to 1 MHz 5 V to 10 V CMC 1,2 % 10 Hz to 40 Hz 10 V to 15 V CMC 0,013 % 40 Hz to 100 Hz 10 V to 15 V CMC 0,011 % 100 Hz to 2 kHz 10 V to 15 V CMC 0,0086 % 2 kHz to 10 kHz 10 V to 15 V CMC 0,011 % 10 kHz to 30 kHz 10 V to 15 V CMC 0,025 % 30 kHz to 100 kHz 10 V to 15 V CMC 0,071 % 100 kHz to 300 kHz 10 V to 15 V CMC 0,51 % 300 kHz to 1 MHz 10 V to 15 V CMC 3,1 % 10 Hz to 40 Hz 15 V to 20 V CMC 0,012 % 40 Hz to 100 Hz 15 V to 20 V CMC 0,0099 % 100 Hz to 2 kHz 15 V to 20 V CMC 0,0079 % 2 kHz to 10 kHz 15 V to 20 V CMC 0,010 % 10 kHz to 30 kHz 15 V to 20 V CMC 0,024 % 30 kHz to 100 kHz 15 V to 20 V CMC 0,065 % 100 kHz to 300 kHz 15 V to 20 V CMC 0,44 % 300 kHz to 1 MHz 15 V to 20 V CMC 2,4 % 10 Hz to 40 Hz 20 V to 30 V CMC 0,021 % 40 Hz to 100 Hz 20 V to 30 V CMC 0,019 % 100 Hz to 2 kHz 20 V to 30 V CMC 0,017 % 2 kHz to 10 kHz 20 V to 30 V CMC 0,019 % 10 kHz to 30 kHz 20 V to 30 V CMC 0,041 % 30 kHz to 100 kHz 20 V to 30 V CMC 0,16 % 10 Hz to 40 Hz 30 V to 50 V CMC 0,018 % 40 Hz to 100 Hz 30 V to 50 V CMC 0,016 % 100 Hz to 2 kHz 30 V to 50 V CMC 0,014 % 2 kHz to 10 kHz 30 V to 50 V CMC 0,016 % 10 kHz to 30 kHz 30 V to 50 V CMC 0,034 % 30 kHz to 100 kHz 30 V to 50 V CMC 0,12 % 10 Hz to 40 Hz 50 V to 100 V CMC 0,015 % 40 Hz to 100 Hz 50 V to 100 V CMC 0,013 % 100 Hz to 2 kHz 50 V to 100 V CMC 0,011 % 2 kHz to 10 kHz 50 V to 100 V CMC 0,013 % 10 kHz to 30 kHz 50 V to 100 V CMC 0,029 % 30 kHz to 100 kHz 50 V to 100 V CMC 0,091 % 10 Hz to 40 Hz 100 V to 150 V CMC 0,013 % 40 Hz to 100 Hz 100 V to 150 V CMC 0,011 % 100 Hz to 2 kHz 100 V to 150 V CMC 0,0086 % 2 kHz to 10 kHz 100 V to 150 V CMC 0,011 % 10 kHz to 30 kHz 100 V to 150 V CMC 0,025 % 30 kHz to 100 kHz 100 V to 150 V CMC 0,071 % 10 Hz to 40 Hz 150 V to 200 V CMC 0,012 % 40 Hz to 100 Hz 150 V to 200 V CMC 0,0099 % 100 Hz to 2 kHz 150 V to 200 V CMC 0,0079 % 2 kHz to 10 kHz 150 V to 200 V CMC 0,010 % 10 kHz to 30 kHz 150 V to 200 V CMC 0,024 % 30 kHz to 100 kHz 150 V to 200 V CMC 0,065 % 40 Hz to 10 kHz 200 V to 300 V CMC 0,020 % 10 kHz to 30 kHz 200 V to 300 V CMC 0,041 % 30 kHz to 100 kHz 200 V to 300 V CMC 0,11 % 40 Hz to 10 kHz 300 V to 400 V CMC 0,017 % 10 kHz to 30 kHz 300 V to 400 V CMC 0,034 % 30 kHz to 100 kHz 300 V to 400 V CMC 0,077 % 40 Hz to 10 kHz 400 V to 500 V CMC 0,016 % 10 kHz to 20 kHz 400 V to 500 V CMC 0,035 % 20 kHz to 30 kHz 400 V to 500 V CMC 0,039 % 30 kHz to 100 kHz 400 V to 500 V CMC 0,063 % 40 Hz to 10 kHz 500 V to 600 V CMC 0,017 % 10 kHz to 20 kHz 500 V to 600 V CMC 0,040 % 20 kHz to 30 kHz 500 V to 600 V CMC 0,049 % 30 kHz to 100 kHz 500 V to 600 V CMC 0,065 % 40 Hz to 10 kHz 600 V to 700 V CMC 0,019 % 10 kHz to 20 kHz 600 V to 700 V CMC 0,049 % 20 kHz to 30 kHz 600 V to 700 V CMC 0,065 % 30 kHz to 100 kHz 600 V to 700 V CMC 0,077 % 40 Hz to 10 kHz 700 V to 800 V CMC 0,023 % 10 kHz to 20 kHz 700 V to 800 V CMC 0,061 % 20 kHz to 30 kHz 700 V to 800 V CMC 0,086 % 30 kHz to 100 kHz 700 V to 800 V CMC 0,095 % 40 Hz to 10 kHz 800 V to 900 V CMC 0,027 % 10 kHz to 20 kHz 800 V to 900 V CMC 0,076 % 20 kHz to 100 kHz 800 V to 900 V CMC 0,12 % 40 Hz to 10 kHz 900 V to 1000 V CMC 0,032 % 10 kHz to 20 kHz 900 V to 1000 V CMC 0,094 % 20 kHz to 100 kHz 900 V to 1000 V CMC 0,15 % 40 Hz to 10 kHz 1000 V to 1050 V CMC 0,034 % 10 kHz to 20 kHz 1000 V to 1050 V CMC 0,11 % 20 kHz to 100 kHz 1000 V to 1050 V CMC 0,16 % TP2, TP21","search_zh":"交流电压 / 交流电压源 校准 – 电学量 用万用表直接测量 10 Hz 至 40 Hz 1,2 mV 至 2 mV CMC 4,4 µV 40 Hz 至 1 kHz 1,2 mV 至 2 mV CMC 2,1 µV 1 kHz 至 20 kHz 1,2 mV 至 2 mV CMC 2,3 µV 20 kHz 至 50 kHz 1,2 mV 至 2 mV CMC 3,8 µV 50 kHz 至 100 kHz 1,2 mV 至 2 mV CMC 13 µV 10 Hz 至 100 Hz 2 mV 至 4 mV CMC 4,6 µV 100 Hz 至 2 kHz 2 mV 至 4 mV CMC 2,5 µV 2 kHz 至 10 kHz 2 mV 至 4 mV CMC 4,5 µV 10 kHz 至 50 kHz 2 mV 至 4 mV CMC 6,3 µV 30 kHz 至 100 kHz 2 mV 至 4 mV CMC 23 µV 10 Hz 至 40 Hz 4 mV 至 10 mV CMC 5,4 µV 40 Hz 至 100 Hz 4 mV 至 10 mV CMC 5,2 µV 100 Hz 至 2 kHz 4 mV 至 10 mV CMC 3,1 µV 2 kHz 至 10 kHz 4 mV 至 10 mV CMC 5,1 µV 10 kHz 至 30 kHz 4 mV 至 10 mV CMC 12 µV 30 kHz 至 100 kHz 4 mV 至 10 mV CMC 28 µV 50 kHz 至 100 kHz 4 mV 至 10 mV CMC 35 µV 10 Hz 至 40 Hz 10 mV 至 15 mV CMC 6,0 µV 40 Hz 至 100 Hz 10 mV 至 15 mV CMC 5,7 µV 100 Hz 至 2 kHz 10 mV 至 15 mV CMC 3,6 µV 2 kHz 至 10 kHz 10 mV 至 15 mV CMC 5,6 µV 10 kHz 至 30 kHz 10 mV 至 15 mV CMC 13 µV 30 kHz 至 100 kHz 10 mV 至 15 mV CMC 31 µV 10 Hz 至 40 Hz 15 mV 至 20 mV CMC 6,7 µV 40 Hz 至 100 Hz 15 mV 至 20 mV CMC 6,3 µV 100 Hz 至 2 kHz 15 mV 至 20 mV CMC 4,2 µV 2 kHz 至 10 kHz 15 mV 至 20 mV CMC 6,2 µV 10 kHz 至 30 kHz 15 mV 至 20 mV CMC 11 µV 30 kHz 至 100 kHz 15 mV 至 20 mV CMC 23 µV 100 kHz 至 300 kHz 15 mV 至 20 mV CMC 82 µV 300 kHz 至 1 MHz 15 mV 至 20 mV CMC 0,19 mV 10 Hz 至 40 Hz 20 mV 至 30 mV CMC 0,034 % 40 Hz 至 100 Hz 20 mV 至 30 mV CMC 0,032 % 100 Hz 至 2 kHz 20 mV 至 30 mV CMC 0,021 % 2 kHz 至 10 kHz 20 mV 至 30 mV CMC 0,031 % 10 kHz 至 30 kHz 20 mV 至 30 mV CMC 0,053 % 30 kHz 至 100 kHz 20 mV 至 30 mV CMC 0,12 % 100 kHz 至 300 kHz 20 mV 至 30 mV CMC 0,41 % 300 kHz 至 1 MHz 20 mV 至 30 mV CMC 1,3 % 10 Hz 至 40 Hz 30 mV 至 50 mV CMC 0,027 % 40 Hz 至 100 Hz 30 mV 至 50 mV CMC 0,025 % 100 Hz 至 2 kHz 30 mV 至 50 mV CMC 0,018 % 2 kHz 至 10 kHz 30 mV 至 50 mV CMC 0,024 % 10 kHz 至 30 kHz 30 mV 至 50 mV CMC 0,047 % 30 kHz 至 100 kHz 30 mV 至 50 mV CMC 0,11 % 100 kHz 至 300 kHz 30 mV 至 50 mV CMC 0,39 % 300 kHz 至 1 MHz 30 mV 至 50 mV CMC 1,3 % 10 Hz 至 40 Hz 50 mV 至 100 mV CMC 0,022 % 40 Hz 至 100 Hz 50 mV 至 100 mV CMC 0,020 % 100 Hz 至 2 kHz 50 mV 至 100 mV CMC 0,015 % 2 kHz 至 10 kHz 50 mV 至 100 mV CMC 0,019 % 10 kHz 至 30 kHz 50 mV 至 100 mV CMC 0,044 % 30 kHz 至 100 kHz 50 mV 至 100 mV CMC 0,11 % 100 kHz 至 300 kHz 50 mV 至 100 mV CMC 0,38 % 300 kHz 至 1 MHz 50 mV 至 100 mV CMC 1,3 % 10 Hz 至 40 Hz 100 mV 至 150 mV CMC 0,018 % 40 Hz 至 100 Hz 100 mV 至 150 mV CMC 0,016 % 100 Hz 至 2 kHz 100 mV 至 150 mV CMC 0,013 % 2 kHz 至 10 kHz 100 mV 至 150 mV CMC 0,015 % 10 kHz 至 30 kHz 100 mV 至 150 mV CMC 0,039 % 30 kHz 至 100 kHz 100 mV 至 150 mV CMC 0,091 % 100 kHz 至 300 kHz 100 mV 至 150 mV CMC 0,45 % 300 kHz 至 1 MHz 100 mV 至 150 mV CMC 1,3 % 10 Hz 至 40 Hz 150 mV 至 200 mV CMC 0,016 % 40 Hz 至 100 Hz 150 mV 至 200 mV CMC 0,014 % 100 Hz 至 2 kHz 150 mV 至 200 mV CMC 0,012 % 2 kHz 至 10 kHz 150 mV 至 200 mV CMC 0,014 % 10 kHz 至 30 kHz 150 mV 至 200 mV CMC 0,036 % 30 kHz 至 100 kHz 150 mV 至 200 mV CMC 0,084 % 100 kHz 至 300 kHz 150 mV 至 200 mV CMC 0,43 % 300 kHz 至 1 MHz 150 mV 至 200 mV CMC 1,3 % 10 Hz 至 40 Hz 200 mV 至 300 mV CMC 0,021 % 40 Hz 至 100 Hz 200 mV 至 300 mV CMC 0,019 % 100 Hz 至 2 kHz 200 mV 至 300 mV CMC 0,017 % 2 kHz 至 10 kHz 200 mV 至 300 mV CMC 0,019 % 10 kHz 至 30 kHz 200 mV 至 300 mV CMC 0,041 % 30 kHz 至 100 kHz 200 mV 至 300 mV CMC 0,11 % 100 kHz 至 300 kHz 200 mV 至 300 mV CMC 0,41 % 300 kHz 至 1 MHz 200 mV 至 300 mV CMC 1,3 % 10 Hz 至 40 Hz 300 mV 至 500 mV CMC 0,018 % 40 Hz 至 100 Hz 300 mV 至 500 mV CMC 0,016 % 100 Hz 至 2 kHz 300 mV 至 500 mV CMC 0,014 % 2 kHz 至 10 kHz 300 mV 至 500 mV CMC 0,016 % 10 kHz 至 30 kHz 300 mV 至 500 mV CMC 0,034 % 30 kHz 至 100 kHz 300 mV 至 500 mV CMC 0,11 % 100 kHz 至 300 kHz 300 mV 至 500 mV CMC 0,39 % 300 kHz 至 1 MHz 300 mV 至 500 mV CMC 1,3 % 10 Hz 至 40 Hz 500 mV 至 1 V CMC 0,015 % 40 Hz 至 100 Hz 500 mV 至 1 V CMC 0,013 % 100 Hz 至 2 kHz 500 mV 至 1 V CMC 0,011 % 2 kHz 至 10 kHz 500 mV 至 1 V CMC 0,013 % 10 kHz 至 30 kHz 500 mV 至 1 V CMC 0,029 % 30 kHz 至 100 kHz 500 mV 至 1 V CMC 0,091 % 100 kHz 至 300 kHz 500 mV 至 1 V CMC 0,38 % 300 kHz 至 1 MHz 500 mV 至 1 V CMC 1,2 % 10 Hz 至 40 Hz 1 V 至 1,5 V CMC 0,013 % 40 Hz 至 100 Hz 1 V 至 1,5 V CMC 0,011 % 100 Hz 至 2 kHz 1 V 至 1,5 V CMC 0,0086 % 2 kHz 至 10 kHz 1 V 至 1,5 V CMC 0,011 % 10 kHz 至 30 kHz 1 V 至 1,5 V CMC 0,025 % 30 kHz 至 100 kHz 1 V 至 1,5 V CMC 0,071 % 100 kHz 至 300 kHz 1 V 至 1,5 V CMC 0,45 % 300 kHz 至 1 MHz 1 V 至 1,5 V CMC 1,3 % 10 Hz 至 40 Hz 1,5 V 至 2 V CMC 0,012 % 40 Hz 至 100 Hz 1,5 V 至 2 V CMC 0,0099 % 100 Hz 至 2 kHz 1,5 V 至 2 V CMC 0,0079 % 2 kHz 至 10 kHz 1,5 V 至 2 V CMC 0,010 % 10 kHz 至 30 kHz 1,5 V 至 2 V CMC 0,024 % 30 kHz 至 100 kHz 1,5 V 至 2 V CMC 0,065 % 100 kHz 至 300 kHz 1,5 V 至 2 V CMC 0,43 % 300 kHz 至 1 MHz 1,5 V 至 2 V CMC 1,3 % 10 Hz 至 40 Hz 2 V 至 3 V CMC 0,021 % 40 Hz 至 100 Hz 2 V 至 3 V CMC 0,019 % 100 Hz 至 2 kHz 2 V 至 3 V CMC 0,017 % 2 kHz 至 10 kHz 2 V 至 3 V CMC 0,019 % 10 kHz 至 30 kHz 2 V 至 3 V CMC 0,041 % 30 kHz 至 100 kHz 2 V 至 3 V CMC 0,11 % 100 kHz 至 300 kHz 2 V 至 3 V CMC 0,41 % 300 kHz 至 1 MHz 2 V 至 3 V CMC 1,3 % 10 Hz 至 40 Hz 3 V 至 5 V CMC 0,018 % 40 Hz 至 100 Hz 3 V 至 5 V CMC 0,016 % 100 Hz 至 2 kHz 3 V 至 5 V CMC 0,014 % 2 kHz 至 10 kHz 3 V 至 5 V CMC 0,016 % 10 kHz 至 30 kHz 3 V 至 5 V CMC 0,034 % 30 kHz 至 100 kHz 3 V 至 5 V CMC 0,11 % 100 kHz 至 300 kHz 3 V 至 5 V CMC 0,39 % 300 kHz 至 1 MHz 3 V 至 5 V CMC 1,3 % 10 Hz 至 40 Hz 5 V 至 10 V CMC 0,015 % 40 Hz 至 100 Hz 5 V 至 10 V CMC 0,013 % 100 Hz 至 2 kHz 5 V 至 10 V CMC 0,011 % 2 kHz 至 10 kHz 5 V 至 10 V CMC 0,013 % 10 kHz 至 30 kHz 5 V 至 10 V CMC 0,029 % 30 kHz 至 100 kHz 5 V 至 10 V CMC 0,091 % 100 kHz 至 300 kHz 5 V 至 10 V CMC 0,38 % 300 kHz 至 1 MHz 5 V 至 10 V CMC 1,2 % 10 Hz 至 40 Hz 10 V 至 15 V CMC 0,013 % 40 Hz 至 100 Hz 10 V 至 15 V CMC 0,011 % 100 Hz 至 2 kHz 10 V 至 15 V CMC 0,0086 % 2 kHz 至 10 kHz 10 V 至 15 V CMC 0,011 % 10 kHz 至 30 kHz 10 V 至 15 V CMC 0,025 % 30 kHz 至 100 kHz 10 V 至 15 V CMC 0,071 % 100 kHz 至 300 kHz 10 V 至 15 V CMC 0,51 % 300 kHz 至 1 MHz 10 V 至 15 V CMC 3,1 % 10 Hz 至 40 Hz 15 V 至 20 V CMC 0,012 % 40 Hz 至 100 Hz 15 V 至 20 V CMC 0,0099 % 100 Hz 至 2 kHz 15 V 至 20 V CMC 0,0079 % 2 kHz 至 10 kHz 15 V 至 20 V CMC 0,010 % 10 kHz 至 30 kHz 15 V 至 20 V CMC 0,024 % 30 kHz 至 100 kHz 15 V 至 20 V CMC 0,065 % 100 kHz 至 300 kHz 15 V 至 20 V CMC 0,44 % 300 kHz 至 1 MHz 15 V 至 20 V CMC 2,4 % 10 Hz 至 40 Hz 20 V 至 30 V CMC 0,021 % 40 Hz 至 100 Hz 20 V 至 30 V CMC 0,019 % 100 Hz 至 2 kHz 20 V 至 30 V CMC 0,017 % 2 kHz 至 10 kHz 20 V 至 30 V CMC 0,019 % 10 kHz 至 30 kHz 20 V 至 30 V CMC 0,041 % 30 kHz 至 100 kHz 20 V 至 30 V CMC 0,16 % 10 Hz 至 40 Hz 30 V 至 50 V CMC 0,018 % 40 Hz 至 100 Hz 30 V 至 50 V CMC 0,016 % 100 Hz 至 2 kHz 30 V 至 50 V CMC 0,014 % 2 kHz 至 10 kHz 30 V 至 50 V CMC 0,016 % 10 kHz 至 30 kHz 30 V 至 50 V CMC 0,034 % 30 kHz 至 100 kHz 30 V 至 50 V CMC 0,12 % 10 Hz 至 40 Hz 50 V 至 100 V CMC 0,015 % 40 Hz 至 100 Hz 50 V 至 100 V CMC 0,013 % 100 Hz 至 2 kHz 50 V 至 100 V CMC 0,011 % 2 kHz 至 10 kHz 50 V 至 100 V CMC 0,013 % 10 kHz 至 30 kHz 50 V 至 100 V CMC 0,029 % 30 kHz 至 100 kHz 50 V 至 100 V CMC 0,091 % 10 Hz 至 40 Hz 100 V 至 150 V CMC 0,013 % 40 Hz 至 100 Hz 100 V 至 150 V CMC 0,011 % 100 Hz 至 2 kHz 100 V 至 150 V CMC 0,0086 % 2 kHz 至 10 kHz 100 V 至 150 V CMC 0,011 % 10 kHz 至 30 kHz 100 V 至 150 V CMC 0,025 % 30 kHz 至 100 kHz 100 V 至 150 V CMC 0,071 % 10 Hz 至 40 Hz 150 V 至 200 V CMC 0,012 % 40 Hz 至 100 Hz 150 V 至 200 V CMC 0,0099 % 100 Hz 至 2 kHz 150 V 至 200 V CMC 0,0079 % 2 kHz 至 10 kHz 150 V 至 200 V CMC 0,010 % 10 kHz 至 30 kHz 150 V 至 200 V CMC 0,024 % 30 kHz 至 100 kHz 150 V 至 200 V CMC 0,065 % 40 Hz 至 10 kHz 200 V 至 300 V CMC 0,020 % 10 kHz 至 30 kHz 200 V 至 300 V CMC 0,041 % 30 kHz 至 100 kHz 200 V 至 300 V CMC 0,11 % 40 Hz 至 10 kHz 300 V 至 400 V CMC 0,017 % 10 kHz 至 30 kHz 300 V 至 400 V CMC 0,034 % 30 kHz 至 100 kHz 300 V 至 400 V CMC 0,077 % 40 Hz 至 10 kHz 400 V 至 500 V CMC 0,016 % 10 kHz 至 20 kHz 400 V 至 500 V CMC 0,035 % 20 kHz 至 30 kHz 400 V 至 500 V CMC 0,039 % 30 kHz 至 100 kHz 400 V 至 500 V CMC 0,063 % 40 Hz 至 10 kHz 500 V 至 600 V CMC 0,017 % 10 kHz 至 20 kHz 500 V 至 600 V CMC 0,040 % 20 kHz 至 30 kHz 500 V 至 600 V CMC 0,049 % 30 kHz 至 100 kHz 500 V 至 600 V CMC 0,065 % 40 Hz 至 10 kHz 600 V 至 700 V CMC 0,019 % 10 kHz 至 20 kHz 600 V 至 700 V CMC 0,049 % 20 kHz 至 30 kHz 600 V 至 700 V CMC 0,065 % 30 kHz 至 100 kHz 600 V 至 700 V CMC 0,077 % 40 Hz 至 10 kHz 700 V 至 800 V CMC 0,023 % 10 kHz 至 20 kHz 700 V 至 800 V CMC 0,061 % 20 kHz 至 30 kHz 700 V 至 800 V CMC 0,086 % 30 kHz 至 100 kHz 700 V 至 800 V CMC 0,095 % 40 Hz 至 10 kHz 800 V 至 900 V CMC 0,027 % 10 kHz 至 20 kHz 800 V 至 900 V CMC 0,076 % 20 kHz 至 100 kHz 800 V 至 900 V CMC 0,12 % 40 Hz 至 10 kHz 900 V 至 1000 V CMC 0,032 % 10 kHz 至 20 kHz 900 V 至 1000 V CMC 0,094 % 20 kHz 至 100 kHz 900 V 至 1000 V CMC 0,15 % 40 Hz 至 10 kHz 1000 V 至 1050 V CMC 0,034 % 10 kHz 至 20 kHz 1000 V 至 1050 V CMC 0,11 % 20 kHz 至 100 kHz 1000 V 至 1050 V CMC 0,16 % TP2, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"27729719cabec08c86f99844","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"2","test_object":"Napięcie przemienne / Mierniki napięcia stałego","test_object_en":"AC voltage / DC voltage meters","test_object_zh":"交流电压 / 直流电压测量仪器","test_object_cs":"Střídavé napětí / Měřidla stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 50 kHz","range":"od 0,22 mV do 0,5 mV","cmc":"4,9 µV"},{"name":"50 kHz do 100 kHz","range":"od 0,22 mV do 0,5 mV","cmc":"7,6 µV"},{"name":"10 Hz do 20 Hz","range":"od 0,5 mV do 1 mV","cmc":"5,5 µV"},{"name":"20 Hz do 40 Hz","range":"od 0,5 mV do 1 mV","cmc":"5,2 µV"},{"name":"40 Hz do 20 kHz","range":"od 0,5 mV do 1 mV","cmc":"5,1 µV"},{"name":"20 kHz do 50 kHz","range":"od 0,5 mV do 1 mV","cmc":"5,3 µV"},{"name":"50 kHz do 100 kHz","range":"od 0,5 mV do 1 mV","cmc":"8,5 µV"},{"name":"10 Hz do 20 Hz","range":"od 1 mV do 2,2 mV","cmc":"5,9 µV"},{"name":"20 Hz do 20 kHz","range":"od 1 mV do 2,2 mV","cmc":"5,2 µV"},{"name":"20 kHz do 50 kHz","range":"od 1 mV do 2,2 mV","cmc":"5,6 µV"},{"name":"50 kHz do 100 kHz","range":"od 1 mV do 2,2 mV","cmc":"9,1 µV"},{"name":"100 kHz do 300 kHz","range":"od 1 mV do 2,2 mV","cmc":"16 µV"},{"name":"300 kHz do 500 kHz","range":"od 1 mV do 2,2 mV","cmc":"30 µV"},{"name":"500 kHz do 1 MHz","range":"od 1 mV do 2,2 mV","cmc":"34 µV"},{"name":"10 Hz do 20 Hz","range":"od 2,2 mV do 3 mV","cmc":"6,8 µV"},{"name":"20 Hz do 40 Hz","range":"od 2,2 mV do 3 mV","cmc":"5,8 µV"},{"name":"40 Hz do 20 kHz","range":"od 2,2 mV do 3 mV","cmc":"5,5 µV"},{"name":"20 kHz do 50 kHz","range":"od 2,2 mV do 3 mV","cmc":"6,3 µV"},{"name":"50 kHz do 100 kHz","range":"od 2,2 mV do 3 mV","cmc":"9,7 µV"},{"name":"100 kHz do 300 kHz","range":"od 2,2 mV do 3 mV","cmc":"16 µV"},{"name":"300 kHz do 500 kHz","range":"od 2,2 mV do 3 mV","cmc":"31 µV"},{"name":"500 kHz do 1 MHz","range":"od 2,2 mV do 3 mV","cmc":"36 µV"},{"name":"10 Hz do 20 Hz","range":"od 3 mV do 5 mV","cmc":"8,0 µV"},{"name":"20 Hz do 40 Hz","range":"od 3 mV do 5 mV","cmc":"6,4 µV"},{"name":"40 Hz do 20 kHz","range":"od 3 mV do 5 mV","cmc":"5,9 µV"},{"name":"20 kHz do 50 kHz","range":"od 3 mV do 5 mV","cmc":"7,1 µV"},{"name":"50 kHz do 100 kHz","range":"od 3 mV do 5 mV","cmc":"12 µV"},{"name":"100 kHz do 300 kHz","range":"od 3 mV do 5 mV","cmc":"18 µV"},{"name":"300 kHz do 500 kHz","range":"od 3 mV do 5 mV","cmc":"35 µV"},{"name":"500 kHz do 1 MHz","range":"od 3 mV do 5 mV","cmc":"43 µV"},{"name":"10 Hz do 20 Hz","range":"od 5 mV do 10 mV","cmc":"12 µV"},{"name":"20 Hz do 40 Hz","range":"od 5 mV do 10 mV","cmc":"8,0 µV"},{"name":"40 Hz do 20 kHz","range":"od 5 mV do 10 mV","cmc":"7,1 µV"},{"name":"20 kHz do 50 kHz","range":"od 5 mV do 10 mV","cmc":"9,4 µV"},{"name":"50 kHz do 100 kHz","range":"od 5 mV do 10 mV","cmc":"17 µV"},{"name":"100 kHz do 300 kHz","range":"od 5 mV do 10 mV","cmc":"25 µV"},{"name":"300 kHz do 500 kHz","range":"od 5 mV do 10 mV","cmc":"44 µV"},{"name":"500 kHz do 1 MHz","range":"od 5 mV do 10 mV","cmc":"61 µV"},{"name":"10 Hz do 20 Hz","range":"od 10 mV do 15 mV","cmc":"14 µV"},{"name":"20 Hz do 40 Hz","range":"od 10 mV do 15 mV","cmc":"8,8 µV"},{"name":"40 Hz do 20 kHz","range":"od 10 mV do 15 mV","cmc":"7,3 µV"},{"name":"20 kHz do 50 kHz","range":"od 10 mV do 15 mV","cmc":"12 µV"},{"name":"50 kHz do 100 kHz","range":"od 10 mV do 15 mV","cmc":"21 µV"},{"name":"100 kHz do 300 kHz","range":"od 10 mV do 15 mV","cmc":"31 µV"},{"name":"300 kHz do 500 kHz","range":"od 10 mV do 15 mV","cmc":"54 µV"},{"name":"500 kHz do 1 MHz","range":"od 10 mV do 15 mV","cmc":"78 µV"},{"name":"10 Hz do 20 Hz","range":"od 15 mV do 22 mV","cmc":"18 µV"},{"name":"20 Hz do 40 Hz","range":"od 15 mV do 22 mV","cmc":"10 µV"},{"name":"40 Hz do 20 kHz","range":"od 15 mV do 22 mV","cmc":"7,7 µV"},{"name":"20 kHz do 50 kHz","range":"od 15 mV do 22 mV","cmc":"14 µV"},{"name":"50 kHz do 100 kHz","range":"od 15 mV do 22 mV","cmc":"27 µV"},{"name":"100 kHz do 300 kHz","range":"od 15 mV do 22 mV","cmc":"39 µV"},{"name":"300 kHz do 500 kHz","range":"od 15 mV do 22 mV","cmc":"67 µV"},{"name":"500 kHz do 1 MHz","range":"od 15 mV do 22 mV","cmc":"0,11 mV"},{"name":"10 Hz do 20 Hz","range":"od 22 mV do 30 mV","cmc":"0,12 %"},{"name":"20 Hz do 40 Hz","range":"od 22 mV do 30 mV","cmc":"0,059 %"},{"name":"40 Hz do 20 kHz","range":"od 22 mV do 30 mV","cmc":"0,048 %"},{"name":"20 kHz do 50 kHz","range":"od 22 mV do 30 mV","cmc":"0,072 %"},{"name":"50 kHz do 100 kHz","range":"od 22 mV do 30 mV","cmc":"0,21 %"},{"name":"100 kHz do 300 kHz","range":"od 22 mV do 30 mV","cmc":"0,24 %"},{"name":"300 kHz do 500 kHz","range":"od 22 mV do 30 mV","cmc":"0,35 %"},{"name":"500 kHz do 1 MHz","range":"od 22 mV do 30 mV","cmc":"0,72 %"},{"name":"10 Hz do 20 Hz","range":"od 30 mV do 50 mV","cmc":"0,099 %"},{"name":"20 Hz do 40 Hz","range":"od 30 mV do 50 mV","cmc":"0,049 %"},{"name":"40 Hz do 20 kHz","range":"od 30 mV do 50 mV","cmc":"0,039 %"},{"name":"20 kHz do 50 kHz","range":"od 30 mV do 50 mV","cmc":"0,062 %"},{"name":"50 kHz do 100 kHz","range":"od 30 mV do 50 mV","cmc":"0,18 %"},{"name":"100 kHz do 300 kHz","range":"od 30 mV do 50 mV","cmc":"0,21 %"},{"name":"300 kHz do 500 kHz","range":"od 30 mV do 50 mV","cmc":"0,31 %"},{"name":"500 kHz do 1 MHz","range":"od 30 mV do 50 mV","cmc":"0,62 %"},{"name":"10 Hz do 20 Hz","range":"od 50 mV do 100 mV","cmc":"0,082 %"},{"name":"20 Hz do 40 Hz","range":"od 50 mV do 100 mV","cmc":"0,039 %"},{"name":"40 Hz do 20 kHz","range":"od 50 mV do 100 mV","cmc":"0,029 %"},{"name":"20 kHz do 50 kHz","range":"od 50 mV do 100 mV","cmc":"0,052 %"},{"name":"50 kHz do 100 kHz","range":"od 50 mV do 100 mV","cmc":"0,15 %"},{"name":"100 kHz do 300 kHz","range":"od 50 mV do 100 mV","cmc":"0,18 %"},{"name":"300 kHz do 500 kHz","range":"od 50 mV do 100 mV","cmc":"0,27 %"},{"name":"500 kHz do 1 MHz","range":"od 50 mV do 100 mV","cmc":"0,51 %"},{"name":"10 Hz do 20 Hz","range":"od 100 mV do 150 mV","cmc":"0,069 %"},{"name":"20 Hz do 40 Hz","range":"od 100 mV do 150 mV","cmc":"0,031 %"},{"name":"40 Hz do 20 kHz","range":"od 100 mV do 150 mV","cmc":"0,021 %"},{"name":"20 kHz do 50 kHz","range":"od 100 mV do 150 mV","cmc":"0,045 %"},{"name":"50 kHz do 100 kHz","range":"od 100 mV do 150 mV","cmc":"0,12 %"},{"name":"100 kHz do 300 kHz","range":"od 100 mV do 150 mV","cmc":"0,15 %"},{"name":"300 kHz do 500 kHz","range":"od 100 mV do 150 mV","cmc":"0,23 %"},{"name":"500 kHz do 1 MHz","range":"od 100 mV do 150 mV","cmc":"0,44 %"},{"name":"10 Hz do 20 Hz","range":"od 150 mV do 220 mV","cmc":"0,065 %"},{"name":"20 Hz do 40 Hz","range":"od 150 mV do 220 mV","cmc":"0,028 %"},{"name":"40 Hz do 20 kHz","range":"od 150 mV do 220 mV","cmc":"0,017 %"},{"name":"20 kHz do 50 kHz","range":"od 150 mV do 220 mV","cmc":"0,039 %"},{"name":"50 kHz do 100 kHz","range":"od 150 mV do 220 mV","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 150 mV do 220 mV","cmc":"0,13 %"},{"name":"300 kHz do 500 kHz","range":"od 150 mV do 220 mV","cmc":"0,21 %"},{"name":"500 kHz do 1 MHz","range":"od 150 mV do 220 mV","cmc":"0,41 %"},{"name":"10 Hz do 20 Hz","range":"od 220 mV do 300 mV","cmc":"0,087 %"},{"name":"20 Hz do 40 Hz","range":"od 220 mV do 300 mV","cmc":"0,028 %"},{"name":"40 Hz do 20 kHz","range":"od 220 mV do 300 mV","cmc":"0,011 %"},{"name":"20 kHz do 50 kHz","range":"od 220 mV do 300 mV","cmc":"0,020 %"},{"name":"50 kHz do 100 kHz","range":"od 220 mV do 300 mV","cmc":"0,058 %"},{"name":"100 kHz do 300 kHz","range":"od 220 mV do 300 mV","cmc":"0,11 %"},{"name":"300 kHz do 500 kHz","range":"od 220 mV do 300 mV","cmc":"0,28 %"},{"name":"500 kHz do 1 MHz","range":"od 220 mV do 300 mV","cmc":"0,61 %"},{"name":"10 Hz do 20 Hz","range":"od 300 mV do 500 mV","cmc":"0,078 %"},{"name":"20 Hz do 40 Hz","range":"od 300 mV do 500 mV","cmc":"0,025 %"},{"name":"40 Hz do 20 kHz","range":"od 300 mV do 500 mV","cmc":"0,010 %"},{"name":"20 kHz do 50 kHz","range":"od 300 mV do 500 mV","cmc":"0,018 %"},{"name":"50 kHz do 100 kHz","range":"od 300 mV do 500 mV","cmc":"0,049 %"},{"name":"100 kHz do 300 kHz","range":"od 300 mV do 500 mV","cmc":"0,088 %"},{"name":"300 kHz do 500 kHz","range":"od 300 mV do 500 mV","cmc":"0,23 %"},{"name":"500 kHz do 1 MHz","range":"od 300 mV do 500 mV","cmc":"0,51 %"},{"name":"10 Hz do 20 Hz","range":"od 500 mV do 1 V","cmc":"0,067 %"},{"name":"20 Hz do 40 Hz","range":"od 500 mV do 1 V","cmc":"0,022 %"},{"name":"40 Hz do 20 kHz","range":"od 500 mV do 1 V","cmc":"0,0092 %"},{"name":"20 kHz do 50 kHz","range":"od 500 mV do 1 V","cmc":"0,016 %"},{"name":"50 kHz do 100 kHz","range":"od 500 mV do 1 V","cmc":"0,040 %"},{"name":"100 kHz do 300 kHz","range":"od 500 mV do 1 V","cmc":"0,071 %"},{"name":"300 kHz do 500 kHz","range":"od 500 mV do 1 V","cmc":"0,19 %"},{"name":"500 kHz do 1 MHz","range":"od 500 mV do 1 V","cmc":"0,40 %"},{"name":"10 Hz do 20 Hz","range":"od 1 V do 1,5 V","cmc":"0,059 %"},{"name":"20 Hz do 40 Hz","range":"od 1 V do 1,5 V","cmc":"0,019 %"},{"name":"40 Hz do 20 kHz","range":"od 1 V do 1,5 V","cmc":"0,0086 %"},{"name":"20 kHz do 50 kHz","range":"od 1 V do 1,5 V","cmc":"0,015 %"},{"name":"50 kHz do 100 kHz","range":"od 1 V do 1,5 V","cmc":"0,033 %"},{"name":"100 kHz do 300 kHz","range":"od 1 V do 1,5 V","cmc":"0,058 %"},{"name":"300 kHz do 500 kHz","range":"od 1 V do 1,5 V","cmc":"0,16 %"},{"name":"500 kHz do 1 MHz","range":"od 1 V do 1,5 V","cmc":"0,32 %"},{"name":"10 Hz do 20 Hz","range":"od 1,5 V do 2,2 V","cmc":"0,056 %"},{"name":"20 Hz do 40 Hz","range":"od 1,5 V do 2,2 V","cmc":"0,019 %"},{"name":"40 Hz do 20 kHz","range":"od 1,5 V do 2,2 V","cmc":"0,0084 %"},{"name":"20 kHz do 50 kHz","range":"od 1,5 V do 2,2 V","cmc":"0,014 %"},{"name":"50 kHz do 100 kHz","range":"od 1,5 V do 2,2 V","cmc":"0,030 %"},{"name":"100 kHz do 300 kHz","range":"od 1,5 V do 2,2 V","cmc":"0,053 %"},{"name":"300 kHz do 500 kHz","range":"od 1,5 V do 2,2 V","cmc":"0,15 %"},{"name":"500 kHz do 1 MHz","range":"od 1,5 V do 2,2 V","cmc":"0,29 %"},{"name":"10 Hz do 20 Hz","range":"od 2,2 V do 3 V","cmc":"0,087 %"},{"name":"20 Hz do 40 Hz","range":"od 2,2 V do 3 V","cmc":"0,028 %"},{"name":"40 Hz do 20 kHz","range":"od 2,2 V do 3 V","cmc":"0,011 %"},{"name":"20 kHz do 50 kHz","range":"od 2,2 V do 3 V","cmc":"0,020 %"},{"name":"50 kHz do 100 kHz","range":"od 2,2 V do 3 V","cmc":"0,042 %"},{"name":"100 kHz do 300 kHz","range":"od 2,2 V do 3 V","cmc":"0,12 %"},{"name":"300 kHz do 500 kHz","range":"od 2,2 V do 3 V","cmc":"0,33 %"},{"name":"500 kHz do 1 MHz","range":"od 2,2 V do 3 V","cmc":"0,67 %"},{"name":"10 Hz do 20 Hz","range":"od 3 V do 5 V","cmc":"0,078 %"},{"name":"20 Hz do 40 Hz","range":"od 3 V do 5 V","cmc":"0,025 %"},{"name":"40 Hz do 20 kHz","range":"od 3 V do 5 V","cmc":"0,099 %"},{"name":"20 kHz do 50 kHz","range":"od 3 V do 5 V","cmc":"0,018 %"},{"name":"50 kHz do 100 kHz","range":"od 3 V do 5 V","cmc":"0,030 %"},{"name":"100 kHz do 300 kHz","range":"od 3 V do 5 V","cmc":"0,11 %"},{"name":"300 kHz do 500 kHz","range":"od 3 V do 5 V","cmc":"0,28 %"},{"name":"500 kHz do 1 MHz","range":"od 3 V do 5 V","cmc":"0,56 %"},{"name":"10 Hz do 20 Hz","range":"od 5 V do 10 V","cmc":"0,067 %"},{"name":"20 Hz do 40 Hz","range":"od 5 V do 10 V","cmc":"0,022 %"},{"name":"40 Hz do 20 kHz","range":"od 5 V do 10 V","cmc":"0,0091 %"},{"name":"20 kHz do 50 kHz","range":"od 5 V do 10 V","cmc":"0,016 %"},{"name":"50 kHz do 100 kHz","range":"od 5 V do 10 V","cmc":"0,033 %"},{"name":"100 kHz do 300 kHz","range":"od 5 V do 10 V","cmc":"0,081 %"},{"name":"300 kHz do 500 kHz","range":"od 5 V do 10 V","cmc":"0,23 %"},{"name":"500 kHz do 1 MHz","range":"od 5 V do 10 V","cmc":"0,45 %"},{"name":"10 Hz do 20 Hz","range":"od 10 V do 15 V","cmc":"0,059 %"},{"name":"20 Hz do 40 Hz","range":"od 10 V do 15 V","cmc":"0,019 %"},{"name":"40 Hz do 20 kHz","range":"od 10 V do 15 V","cmc":"0,0086 %"},{"name":"20 kHz do 50 kHz","range":"od 10 V do 15 V","cmc":"0,014 %"},{"name":"50 kHz do 100 kHz","range":"od 10 V do 15 V","cmc":"0,029 %"},{"name":"100 kHz do 300 kHz","range":"od 10 V do 15 V","cmc":"0,066 %"},{"name":"300 kHz do 500 kHz","range":"od 10 V do 15 V","cmc":"0,19 %"},{"name":"500 kHz do 1 MHz","range":"od 10 V do 15 V","cmc":"0,37 %"},{"name":"10 Hz do 20 Hz","range":"od 15 V do 22 V","cmc":"0,056 %"},{"name":"20 Hz do 40 Hz","range":"od 15 V do 22 V","cmc":"0,019 %"},{"name":"40 Hz do 20 kHz","range":"od 15 V do 22 V","cmc":"0,087 %"},{"name":"20 kHz do 50 kHz","range":"od 15 V do 22 V","cmc":"0,014 %"},{"name":"50 kHz do 100 kHz","range":"od 15 V do 22 V","cmc":"0,029 %"},{"name":"100 kHz do 300 kHz","range":"od 15 V do 22 V","cmc":"0,061 %"},{"name":"300 kHz do 500 kHz","range":"od 15 V do 22 V","cmc":"0,18 %"},{"name":"500 kHz do 1 MHz","range":"od 15 V do 22 V","cmc":"0,34 %"},{"name":"10 Hz do 20 Hz","range":"od 22 V do 30 V","cmc":"0,087 %"},{"name":"20 Hz do 40 Hz","range":"od 22 V do 30 V","cmc":"0,028 %"},{"name":"40 Hz do 20 kHz","range":"od 22 V do 30 V","cmc":"0,013 %"},{"name":"20 kHz do 50 kHz","range":"od 22 V do 30 V","cmc":"0,039 %"},{"name":"50 kHz do 100 kHz","range":"od 22 V do 30 V","cmc":"0,087 %"},{"name":"10 Hz do 20 Hz","range":"od 30 V do 50 V","cmc":"0,078 %"},{"name":"20 Hz do 40 Hz","range":"od 30 V do 50 V","cmc":"0,025 %"},{"name":"40 Hz do 20 kHz","range":"od 30 V do 50 V","cmc":"0,012 %"},{"name":"20 kHz do 50 kHz","range":"od 30 V do 50 V","cmc":"0,034 %"},{"name":"50 kHz do 100 kHz","range":"od 30 V do 50 V","cmc":"0,078 %"},{"name":"10 Hz do 20 Hz","range":"od 50 V do 100 V","cmc":"0,067 %"},{"name":"20 Hz do 40 Hz","range":"od 50 V do 100 V","cmc":"0,022 %"},{"name":"40 Hz do 20 kHz","range":"od 50 V do 100 V","cmc":"0,011 %"},{"name":"20 kHz do 50 kHz","range":"od 50 V do 100 V","cmc":"0,030 %"},{"name":"50 kHz do 100 kHz","range":"od 50 V do 100 V","cmc":"0,067 %"},{"name":"10 Hz do 20 Hz","range":"od 100 V do 150 V","cmc":"0,059 %"},{"name":"20 Hz do 40 Hz","range":"od 100 V do 150 V","cmc":"0,019 %"},{"name":"40 Hz do 20 kHz","range":"od 100 V do 150 V","cmc":"0,010 %"},{"name":"20 kHz do 50 kHz","range":"od 100 V do 150 V","cmc":"0,026 %"},{"name":"50 kHz do 100 kHz","range":"od 100 V do 150 V","cmc":"0,059 %"},{"name":"10 Hz do 20 Hz","range":"od 150 V do 220 V","cmc":"0,057 %"},{"name":"20 Hz do 40 Hz","range":"od 150 V do 220 V","cmc":"0,019 %"},{"name":"40 Hz do 20 kHz","range":"od 150 V do 220 V","cmc":"0,011 %"},{"name":"20 kHz do 50 kHz","range":"od 150 V do 220 V","cmc":"0,027 %"},{"name":"50 kHz do 100 kHz","range":"od 150 V do 220 V","cmc":"0,065 %"},{"name":"10 Hz do 50 Hz","range":"od 220 V do 300 V","cmc":"0,030 %"},{"name":"50 Hz do 1 kHz","range":"od 220 V do 300 V","cmc":"0,012 %"},{"name":"1 kHz do 10 kHz","range":"od 220 V do 300 V","cmc":"0,026 %"},{"name":"10 kHz do 30 kHz","range":"od 220 V do 300 V","cmc":"0,042 %"},{"name":"10 Hz do 50 Hz","range":"od 300 V do 400 V","cmc":"0,030 %"},{"name":"50 Hz do 1 kHz","range":"od 300 V do 400 V","cmc":"0,012 %"},{"name":"1 kHz do 10 kHz","range":"od 300 V do 400 V","cmc":"0,026 %"},{"name":"10 kHz do 30 kHz","range":"od 300 V do 400 V","cmc":"0,042 %"},{"name":"10 Hz do 50 Hz","range":"od 400 V do 500 V","cmc":"0,028 %"},{"name":"50 Hz do 1 kHz","range":"od 400 V do 500 V","cmc":"0,012 %"},{"name":"1 kHz do 10 kHz","range":"od 400 V do 500 V","cmc":"0,025 %"},{"name":"10 kHz do 30 kHz","range":"od 400 V do 500 V","cmc":"0,045 %"},{"name":"10 Hz do 50 Hz","range":"od 500 V do 600 V","cmc":"0,027 %"},{"name":"50 Hz do 1 kHz","range":"od 500 V do 600 V","cmc":"0,011 %"},{"name":"1 kHz do 10 kHz","range":"od 500 V do 600 V","cmc":"0,023 %"},{"name":"10 kHz do 30 kHz","range":"od 500 V do 600 V","cmc":"0,053 %"},{"name":"10 Hz do 50 Hz","range":"od 600 V do 700 V","cmc":"0,028 %"},{"name":"50 Hz do 1 kHz","range":"od 600 V do 700 V","cmc":"0,012 %"},{"name":"1 kHz do 10 kHz","range":"od 600 V do 700 V","cmc":"0,025 %"},{"name":"10 kHz do 30 kHz","range":"od 600 V do 700 V","cmc":"0,068 %"},{"name":"10 Hz do 50 Hz","range":"od 700 V do 800 V","cmc":"0,030 %"},{"name":"50 Hz do 1 kHz","range":"od 700 V do 800 V","cmc":"0,011 %"},{"name":"1 kHz do 10 kHz","range":"od 700 V do 800 V","cmc":"0,028 %"},{"name":"10 kHz do 30 kHz","range":"od 700 V do 800 V","cmc":"0,089 %"},{"name":"10 Hz do 50 Hz","range":"od 800 V do 1050 V","cmc":"0,040 %"},{"name":"50 Hz do 1 kHz","range":"od 800 V do 1050 V","cmc":"0,010 %"},{"name":"1 kHz do 10 kHz","range":"od 800 V do 1050 V","cmc":"0,038 %"},{"name":"10 kHz do 30 kHz","range":"od 800 V do 1050 V","cmc":"0,17 %"}],"parameters_en":[{"name":"10 Hz to 50 kHz","range":"0,22 mV to 0,5 mV","cmc":"4,9 µV"},{"name":"50 kHz to 100 kHz","range":"0,22 mV to 0,5 mV","cmc":"7,6 µV"},{"name":"10 Hz to 20 Hz","range":"0,5 mV to 1 mV","cmc":"5,5 µV"},{"name":"20 Hz to 40 Hz","range":"0,5 mV to 1 mV","cmc":"5,2 µV"},{"name":"40 Hz to 20 kHz","range":"0,5 mV to 1 mV","cmc":"5,1 µV"},{"name":"20 kHz to 50 kHz","range":"0,5 mV to 1 mV","cmc":"5,3 µV"},{"name":"50 kHz to 100 kHz","range":"0,5 mV to 1 mV","cmc":"8,5 µV"},{"name":"10 Hz to 20 Hz","range":"1 mV to 2,2 mV","cmc":"5,9 µV"},{"name":"20 Hz to 20 kHz","range":"1 mV to 2,2 mV","cmc":"5,2 µV"},{"name":"20 kHz to 50 kHz","range":"1 mV to 2,2 mV","cmc":"5,6 µV"},{"name":"50 kHz to 100 kHz","range":"1 mV to 2,2 mV","cmc":"9,1 µV"},{"name":"100 kHz to 300 kHz","range":"1 mV to 2,2 mV","cmc":"16 µV"},{"name":"300 kHz to 500 kHz","range":"1 mV to 2,2 mV","cmc":"30 µV"},{"name":"500 kHz to 1 MHz","range":"1 mV to 2,2 mV","cmc":"34 µV"},{"name":"10 Hz to 20 Hz","range":"2,2 mV to 3 mV","cmc":"6,8 µV"},{"name":"20 Hz to 40 Hz","range":"2,2 mV to 3 mV","cmc":"5,8 µV"},{"name":"40 Hz to 20 kHz","range":"2,2 mV to 3 mV","cmc":"5,5 µV"},{"name":"20 kHz to 50 kHz","range":"2,2 mV to 3 mV","cmc":"6,3 µV"},{"name":"50 kHz to 100 kHz","range":"2,2 mV to 3 mV","cmc":"9,7 µV"},{"name":"100 kHz to 300 kHz","range":"2,2 mV to 3 mV","cmc":"16 µV"},{"name":"300 kHz to 500 kHz","range":"2,2 mV to 3 mV","cmc":"31 µV"},{"name":"500 kHz to 1 MHz","range":"2,2 mV to 3 mV","cmc":"36 µV"},{"name":"10 Hz to 20 Hz","range":"3 mV to 5 mV","cmc":"8,0 µV"},{"name":"20 Hz to 40 Hz","range":"3 mV to 5 mV","cmc":"6,4 µV"},{"name":"40 Hz to 20 kHz","range":"3 mV to 5 mV","cmc":"5,9 µV"},{"name":"20 kHz to 50 kHz","range":"3 mV to 5 mV","cmc":"7,1 µV"},{"name":"50 kHz to 100 kHz","range":"3 mV to 5 mV","cmc":"12 µV"},{"name":"100 kHz to 300 kHz","range":"3 mV to 5 mV","cmc":"18 µV"},{"name":"300 kHz to 500 kHz","range":"3 mV to 5 mV","cmc":"35 µV"},{"name":"500 kHz to 1 MHz","range":"3 mV to 5 mV","cmc":"43 µV"},{"name":"10 Hz to 20 Hz","range":"5 mV to 10 mV","cmc":"12 µV"},{"name":"20 Hz to 40 Hz","range":"5 mV to 10 mV","cmc":"8,0 µV"},{"name":"40 Hz to 20 kHz","range":"5 mV to 10 mV","cmc":"7,1 µV"},{"name":"20 kHz to 50 kHz","range":"5 mV to 10 mV","cmc":"9,4 µV"},{"name":"50 kHz to 100 kHz","range":"5 mV to 10 mV","cmc":"17 µV"},{"name":"100 kHz to 300 kHz","range":"5 mV to 10 mV","cmc":"25 µV"},{"name":"300 kHz to 500 kHz","range":"5 mV to 10 mV","cmc":"44 µV"},{"name":"500 kHz to 1 MHz","range":"5 mV to 10 mV","cmc":"61 µV"},{"name":"10 Hz to 20 Hz","range":"10 mV to 15 mV","cmc":"14 µV"},{"name":"20 Hz to 40 Hz","range":"10 mV to 15 mV","cmc":"8,8 µV"},{"name":"40 Hz to 20 kHz","range":"10 mV to 15 mV","cmc":"7,3 µV"},{"name":"20 kHz to 50 kHz","range":"10 mV to 15 mV","cmc":"12 µV"},{"name":"50 kHz to 100 kHz","range":"10 mV to 15 mV","cmc":"21 µV"},{"name":"100 kHz to 300 kHz","range":"10 mV to 15 mV","cmc":"31 µV"},{"name":"300 kHz to 500 kHz","range":"10 mV to 15 mV","cmc":"54 µV"},{"name":"500 kHz to 1 MHz","range":"10 mV to 15 mV","cmc":"78 µV"},{"name":"10 Hz to 20 Hz","range":"15 mV to 22 mV","cmc":"18 µV"},{"name":"20 Hz to 40 Hz","range":"15 mV to 22 mV","cmc":"10 µV"},{"name":"40 Hz to 20 kHz","range":"15 mV to 22 mV","cmc":"7,7 µV"},{"name":"20 kHz to 50 kHz","range":"15 mV to 22 mV","cmc":"14 µV"},{"name":"50 kHz to 100 kHz","range":"15 mV to 22 mV","cmc":"27 µV"},{"name":"100 kHz to 300 kHz","range":"15 mV to 22 mV","cmc":"39 µV"},{"name":"300 kHz to 500 kHz","range":"15 mV to 22 mV","cmc":"67 µV"},{"name":"500 kHz to 1 MHz","range":"15 mV to 22 mV","cmc":"0,11 mV"},{"name":"10 Hz to 20 Hz","range":"22 mV to 30 mV","cmc":"0,12 %"},{"name":"20 Hz to 40 Hz","range":"22 mV to 30 mV","cmc":"0,059 %"},{"name":"40 Hz to 20 kHz","range":"22 mV to 30 mV","cmc":"0,048 %"},{"name":"20 kHz to 50 kHz","range":"22 mV to 30 mV","cmc":"0,072 %"},{"name":"50 kHz to 100 kHz","range":"22 mV to 30 mV","cmc":"0,21 %"},{"name":"100 kHz to 300 kHz","range":"22 mV to 30 mV","cmc":"0,24 %"},{"name":"300 kHz to 500 kHz","range":"22 mV to 30 mV","cmc":"0,35 %"},{"name":"500 kHz to 1 MHz","range":"22 mV to 30 mV","cmc":"0,72 %"},{"name":"10 Hz to 20 Hz","range":"30 mV to 50 mV","cmc":"0,099 %"},{"name":"20 Hz to 40 Hz","range":"30 mV to 50 mV","cmc":"0,049 %"},{"name":"40 Hz to 20 kHz","range":"30 mV to 50 mV","cmc":"0,039 %"},{"name":"20 kHz to 50 kHz","range":"30 mV to 50 mV","cmc":"0,062 %"},{"name":"50 kHz to 100 kHz","range":"30 mV to 50 mV","cmc":"0,18 %"},{"name":"100 kHz to 300 kHz","range":"30 mV to 50 mV","cmc":"0,21 %"},{"name":"300 kHz to 500 kHz","range":"30 mV to 50 mV","cmc":"0,31 %"},{"name":"500 kHz to 1 MHz","range":"30 mV to 50 mV","cmc":"0,62 %"},{"name":"10 Hz to 20 Hz","range":"50 mV to 100 mV","cmc":"0,082 %"},{"name":"20 Hz to 40 Hz","range":"50 mV to 100 mV","cmc":"0,039 %"},{"name":"40 Hz to 20 kHz","range":"50 mV to 100 mV","cmc":"0,029 %"},{"name":"20 kHz to 50 kHz","range":"50 mV to 100 mV","cmc":"0,052 %"},{"name":"50 kHz to 100 kHz","range":"50 mV to 100 mV","cmc":"0,15 %"},{"name":"100 kHz to 300 kHz","range":"50 mV to 100 mV","cmc":"0,18 %"},{"name":"300 kHz to 500 kHz","range":"50 mV to 100 mV","cmc":"0,27 %"},{"name":"500 kHz to 1 MHz","range":"50 mV to 100 mV","cmc":"0,51 %"},{"name":"10 Hz to 20 Hz","range":"100 mV to 150 mV","cmc":"0,069 %"},{"name":"20 Hz to 40 Hz","range":"100 mV to 150 mV","cmc":"0,031 %"},{"name":"40 Hz to 20 kHz","range":"100 mV to 150 mV","cmc":"0,021 %"},{"name":"20 kHz to 50 kHz","range":"100 mV to 150 mV","cmc":"0,045 %"},{"name":"50 kHz to 100 kHz","range":"100 mV to 150 mV","cmc":"0,12 %"},{"name":"100 kHz to 300 kHz","range":"100 mV to 150 mV","cmc":"0,15 %"},{"name":"300 kHz to 500 kHz","range":"100 mV to 150 mV","cmc":"0,23 %"},{"name":"500 kHz to 1 MHz","range":"100 mV to 150 mV","cmc":"0,44 %"},{"name":"10 Hz to 20 Hz","range":"150 mV to 220 mV","cmc":"0,065 %"},{"name":"20 Hz to 40 Hz","range":"150 mV to 220 mV","cmc":"0,028 %"},{"name":"40 Hz to 20 kHz","range":"150 mV to 220 mV","cmc":"0,017 %"},{"name":"20 kHz to 50 kHz","range":"150 mV to 220 mV","cmc":"0,039 %"},{"name":"50 kHz to 100 kHz","range":"150 mV to 220 mV","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"150 mV to 220 mV","cmc":"0,13 %"},{"name":"300 kHz to 500 kHz","range":"150 mV to 220 mV","cmc":"0,21 %"},{"name":"500 kHz to 1 MHz","range":"150 mV to 220 mV","cmc":"0,41 %"},{"name":"10 Hz to 20 Hz","range":"220 mV to 300 mV","cmc":"0,087 %"},{"name":"20 Hz to 40 Hz","range":"220 mV to 300 mV","cmc":"0,028 %"},{"name":"40 Hz to 20 kHz","range":"220 mV to 300 mV","cmc":"0,011 %"},{"name":"20 kHz to 50 kHz","range":"220 mV to 300 mV","cmc":"0,020 %"},{"name":"50 kHz to 100 kHz","range":"220 mV to 300 mV","cmc":"0,058 %"},{"name":"100 kHz to 300 kHz","range":"220 mV to 300 mV","cmc":"0,11 %"},{"name":"300 kHz to 500 kHz","range":"220 mV to 300 mV","cmc":"0,28 %"},{"name":"500 kHz to 1 MHz","range":"220 mV to 300 mV","cmc":"0,61 %"},{"name":"10 Hz to 20 Hz","range":"300 mV to 500 mV","cmc":"0,078 %"},{"name":"20 Hz to 40 Hz","range":"300 mV to 500 mV","cmc":"0,025 %"},{"name":"40 Hz to 20 kHz","range":"300 mV to 500 mV","cmc":"0,010 %"},{"name":"20 kHz to 50 kHz","range":"300 mV to 500 mV","cmc":"0,018 %"},{"name":"50 kHz to 100 kHz","range":"300 mV to 500 mV","cmc":"0,049 %"},{"name":"100 kHz to 300 kHz","range":"300 mV to 500 mV","cmc":"0,088 %"},{"name":"300 kHz to 500 kHz","range":"300 mV to 500 mV","cmc":"0,23 %"},{"name":"500 kHz to 1 MHz","range":"300 mV to 500 mV","cmc":"0,51 %"},{"name":"10 Hz to 20 Hz","range":"500 mV to 1 V","cmc":"0,067 %"},{"name":"20 Hz to 40 Hz","range":"500 mV to 1 V","cmc":"0,022 %"},{"name":"40 Hz to 20 kHz","range":"500 mV to 1 V","cmc":"0,0092 %"},{"name":"20 kHz to 50 kHz","range":"500 mV to 1 V","cmc":"0,016 %"},{"name":"50 kHz to 100 kHz","range":"500 mV to 1 V","cmc":"0,040 %"},{"name":"100 kHz to 300 kHz","range":"500 mV to 1 V","cmc":"0,071 %"},{"name":"300 kHz to 500 kHz","range":"500 mV to 1 V","cmc":"0,19 %"},{"name":"500 kHz to 1 MHz","range":"500 mV to 1 V","cmc":"0,40 %"},{"name":"10 Hz to 20 Hz","range":"1 V to 1,5 V","cmc":"0,059 %"},{"name":"20 Hz to 40 Hz","range":"1 V to 1,5 V","cmc":"0,019 %"},{"name":"40 Hz to 20 kHz","range":"1 V to 1,5 V","cmc":"0,0086 %"},{"name":"20 kHz to 50 kHz","range":"1 V to 1,5 V","cmc":"0,015 %"},{"name":"50 kHz to 100 kHz","range":"1 V to 1,5 V","cmc":"0,033 %"},{"name":"100 kHz to 300 kHz","range":"1 V to 1,5 V","cmc":"0,058 %"},{"name":"300 kHz to 500 kHz","range":"1 V to 1,5 V","cmc":"0,16 %"},{"name":"500 kHz to 1 MHz","range":"1 V to 1,5 V","cmc":"0,32 %"},{"name":"10 Hz to 20 Hz","range":"1,5 V to 2,2 V","cmc":"0,056 %"},{"name":"20 Hz to 40 Hz","range":"1,5 V to 2,2 V","cmc":"0,019 %"},{"name":"40 Hz to 20 kHz","range":"1,5 V to 2,2 V","cmc":"0,0084 %"},{"name":"20 kHz to 50 kHz","range":"1,5 V to 2,2 V","cmc":"0,014 %"},{"name":"50 kHz to 100 kHz","range":"1,5 V to 2,2 V","cmc":"0,030 %"},{"name":"100 kHz to 300 kHz","range":"1,5 V to 2,2 V","cmc":"0,053 %"},{"name":"300 kHz to 500 kHz","range":"1,5 V to 2,2 V","cmc":"0,15 %"},{"name":"500 kHz to 1 MHz","range":"1,5 V to 2,2 V","cmc":"0,29 %"},{"name":"10 Hz to 20 Hz","range":"2,2 V to 3 V","cmc":"0,087 %"},{"name":"20 Hz to 40 Hz","range":"2,2 V to 3 V","cmc":"0,028 %"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 3 V","cmc":"0,011 %"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 3 V","cmc":"0,020 %"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 3 V","cmc":"0,042 %"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 3 V","cmc":"0,12 %"},{"name":"300 kHz to 500 kHz","range":"2,2 V to 3 V","cmc":"0,33 %"},{"name":"500 kHz to 1 MHz","range":"2,2 V to 3 V","cmc":"0,67 %"},{"name":"10 Hz to 20 Hz","range":"3 V to 5 V","cmc":"0,078 %"},{"name":"20 Hz to 40 Hz","range":"3 V to 5 V","cmc":"0,025 %"},{"name":"40 Hz to 20 kHz","range":"3 V to 5 V","cmc":"0,099 %"},{"name":"20 kHz to 50 kHz","range":"3 V to 5 V","cmc":"0,018 %"},{"name":"50 kHz to 100 kHz","range":"3 V to 5 V","cmc":"0,030 %"},{"name":"100 kHz to 300 kHz","range":"3 V to 5 V","cmc":"0,11 %"},{"name":"300 kHz to 500 kHz","range":"3 V to 5 V","cmc":"0,28 %"},{"name":"500 kHz to 1 MHz","range":"3 V to 5 V","cmc":"0,56 %"},{"name":"10 Hz to 20 Hz","range":"5 V to 10 V","cmc":"0,067 %"},{"name":"20 Hz to 40 Hz","range":"5 V to 10 V","cmc":"0,022 %"},{"name":"40 Hz to 20 kHz","range":"5 V to 10 V","cmc":"0,0091 %"},{"name":"20 kHz to 50 kHz","range":"5 V to 10 V","cmc":"0,016 %"},{"name":"50 kHz to 100 kHz","range":"5 V to 10 V","cmc":"0,033 %"},{"name":"100 kHz to 300 kHz","range":"5 V to 10 V","cmc":"0,081 %"},{"name":"300 kHz to 500 kHz","range":"5 V to 10 V","cmc":"0,23 %"},{"name":"500 kHz to 1 MHz","range":"5 V to 10 V","cmc":"0,45 %"},{"name":"10 Hz to 20 Hz","range":"10 V to 15 V","cmc":"0,059 %"},{"name":"20 Hz to 40 Hz","range":"10 V to 15 V","cmc":"0,019 %"},{"name":"40 Hz to 20 kHz","range":"10 V to 15 V","cmc":"0,0086 %"},{"name":"20 kHz to 50 kHz","range":"10 V to 15 V","cmc":"0,014 %"},{"name":"50 kHz to 100 kHz","range":"10 V to 15 V","cmc":"0,029 %"},{"name":"100 kHz to 300 kHz","range":"10 V to 15 V","cmc":"0,066 %"},{"name":"300 kHz to 500 kHz","range":"10 V to 15 V","cmc":"0,19 %"},{"name":"500 kHz to 1 MHz","range":"10 V to 15 V","cmc":"0,37 %"},{"name":"10 Hz to 20 Hz","range":"15 V to 22 V","cmc":"0,056 %"},{"name":"20 Hz to 40 Hz","range":"15 V to 22 V","cmc":"0,019 %"},{"name":"40 Hz to 20 kHz","range":"15 V to 22 V","cmc":"0,087 %"},{"name":"20 kHz to 50 kHz","range":"15 V to 22 V","cmc":"0,014 %"},{"name":"50 kHz to 100 kHz","range":"15 V to 22 V","cmc":"0,029 %"},{"name":"100 kHz to 300 kHz","range":"15 V to 22 V","cmc":"0,061 %"},{"name":"300 kHz to 500 kHz","range":"15 V to 22 V","cmc":"0,18 %"},{"name":"500 kHz to 1 MHz","range":"15 V to 22 V","cmc":"0,34 %"},{"name":"10 Hz to 20 Hz","range":"22 V to 30 V","cmc":"0,087 %"},{"name":"20 Hz to 40 Hz","range":"22 V to 30 V","cmc":"0,028 %"},{"name":"40 Hz to 20 kHz","range":"22 V to 30 V","cmc":"0,013 %"},{"name":"20 kHz to 50 kHz","range":"22 V to 30 V","cmc":"0,039 %"},{"name":"50 kHz to 100 kHz","range":"22 V to 30 V","cmc":"0,087 %"},{"name":"10 Hz to 20 Hz","range":"30 V to 50 V","cmc":"0,078 %"},{"name":"20 Hz to 40 Hz","range":"30 V to 50 V","cmc":"0,025 %"},{"name":"40 Hz to 20 kHz","range":"30 V to 50 V","cmc":"0,012 %"},{"name":"20 kHz to 50 kHz","range":"30 V to 50 V","cmc":"0,034 %"},{"name":"50 kHz to 100 kHz","range":"30 V to 50 V","cmc":"0,078 %"},{"name":"10 Hz to 20 Hz","range":"50 V to 100 V","cmc":"0,067 %"},{"name":"20 Hz to 40 Hz","range":"50 V to 100 V","cmc":"0,022 %"},{"name":"40 Hz to 20 kHz","range":"50 V to 100 V","cmc":"0,011 %"},{"name":"20 kHz to 50 kHz","range":"50 V to 100 V","cmc":"0,030 %"},{"name":"50 kHz to 100 kHz","range":"50 V to 100 V","cmc":"0,067 %"},{"name":"10 Hz to 20 Hz","range":"100 V to 150 V","cmc":"0,059 %"},{"name":"20 Hz to 40 Hz","range":"100 V to 150 V","cmc":"0,019 %"},{"name":"40 Hz to 20 kHz","range":"100 V to 150 V","cmc":"0,010 %"},{"name":"20 kHz to 50 kHz","range":"100 V to 150 V","cmc":"0,026 %"},{"name":"50 kHz to 100 kHz","range":"100 V to 150 V","cmc":"0,059 %"},{"name":"10 Hz to 20 Hz","range":"150 V to 220 V","cmc":"0,057 %"},{"name":"20 Hz to 40 Hz","range":"150 V to 220 V","cmc":"0,019 %"},{"name":"40 Hz to 20 kHz","range":"150 V to 220 V","cmc":"0,011 %"},{"name":"20 kHz to 50 kHz","range":"150 V to 220 V","cmc":"0,027 %"},{"name":"50 kHz to 100 kHz","range":"150 V to 220 V","cmc":"0,065 %"},{"name":"10 Hz to 50 Hz","range":"220 V to 300 V","cmc":"0,030 %"},{"name":"50 Hz to 1 kHz","range":"220 V to 300 V","cmc":"0,012 %"},{"name":"1 kHz to 10 kHz","range":"220 V to 300 V","cmc":"0,026 %"},{"name":"10 kHz to 30 kHz","range":"220 V to 300 V","cmc":"0,042 %"},{"name":"10 Hz to 50 Hz","range":"300 V to 400 V","cmc":"0,030 %"},{"name":"50 Hz to 1 kHz","range":"300 V to 400 V","cmc":"0,012 %"},{"name":"1 kHz to 10 kHz","range":"300 V to 400 V","cmc":"0,026 %"},{"name":"10 kHz to 30 kHz","range":"300 V to 400 V","cmc":"0,042 %"},{"name":"10 Hz to 50 Hz","range":"400 V to 500 V","cmc":"0,028 %"},{"name":"50 Hz to 1 kHz","range":"400 V to 500 V","cmc":"0,012 %"},{"name":"1 kHz to 10 kHz","range":"400 V to 500 V","cmc":"0,025 %"},{"name":"10 kHz to 30 kHz","range":"400 V to 500 V","cmc":"0,045 %"},{"name":"10 Hz to 50 Hz","range":"500 V to 600 V","cmc":"0,027 %"},{"name":"50 Hz to 1 kHz","range":"500 V to 600 V","cmc":"0,011 %"},{"name":"1 kHz to 10 kHz","range":"500 V to 600 V","cmc":"0,023 %"},{"name":"10 kHz to 30 kHz","range":"500 V to 600 V","cmc":"0,053 %"},{"name":"10 Hz to 50 Hz","range":"600 V to 700 V","cmc":"0,028 %"},{"name":"50 Hz to 1 kHz","range":"600 V to 700 V","cmc":"0,012 %"},{"name":"1 kHz to 10 kHz","range":"600 V to 700 V","cmc":"0,025 %"},{"name":"10 kHz to 30 kHz","range":"600 V to 700 V","cmc":"0,068 %"},{"name":"10 Hz to 50 Hz","range":"700 V to 800 V","cmc":"0,030 %"},{"name":"50 Hz to 1 kHz","range":"700 V to 800 V","cmc":"0,011 %"},{"name":"1 kHz to 10 kHz","range":"700 V to 800 V","cmc":"0,028 %"},{"name":"10 kHz to 30 kHz","range":"700 V to 800 V","cmc":"0,089 %"},{"name":"10 Hz to 50 Hz","range":"800 V to 1050 V","cmc":"0,040 %"},{"name":"50 Hz to 1 kHz","range":"800 V to 1050 V","cmc":"0,010 %"},{"name":"1 kHz to 10 kHz","range":"800 V to 1050 V","cmc":"0,038 %"},{"name":"10 kHz to 30 kHz","range":"800 V to 1050 V","cmc":"0,17 %"}],"parameters_zh":[{"name":"10 Hz 至 50 kHz","range":"0,22 mV 至 0,5 mV","cmc":"4,9 µV"},{"name":"50 kHz 至 100 kHz","range":"0,22 mV 至 0,5 mV","cmc":"7,6 µV"},{"name":"10 Hz 至 20 Hz","range":"0,5 mV 至 1 mV","cmc":"5,5 µV"},{"name":"20 Hz 至 40 Hz","range":"0,5 mV 至 1 mV","cmc":"5,2 µV"},{"name":"40 Hz 至 20 kHz","range":"0,5 mV 至 1 mV","cmc":"5,1 µV"},{"name":"20 kHz 至 50 kHz","range":"0,5 mV 至 1 mV","cmc":"5,3 µV"},{"name":"50 kHz 至 100 kHz","range":"0,5 mV 至 1 mV","cmc":"8,5 µV"},{"name":"10 Hz 至 20 Hz","range":"1 mV 至 2,2 mV","cmc":"5,9 µV"},{"name":"20 Hz 至 20 kHz","range":"1 mV 至 2,2 mV","cmc":"5,2 µV"},{"name":"20 kHz 至 50 kHz","range":"1 mV 至 2,2 mV","cmc":"5,6 µV"},{"name":"50 kHz 至 100 kHz","range":"1 mV 至 2,2 mV","cmc":"9,1 µV"},{"name":"100 kHz 至 300 kHz","range":"1 mV 至 2,2 mV","cmc":"16 µV"},{"name":"300 kHz 至 500 kHz","range":"1 mV 至 2,2 mV","cmc":"30 µV"},{"name":"500 kHz 至 1 MHz","range":"1 mV 至 2,2 mV","cmc":"34 µV"},{"name":"10 Hz 至 20 Hz","range":"2,2 mV 至 3 mV","cmc":"6,8 µV"},{"name":"20 Hz 至 40 Hz","range":"2,2 mV 至 3 mV","cmc":"5,8 µV"},{"name":"40 Hz 至 20 kHz","range":"2,2 mV 至 3 mV","cmc":"5,5 µV"},{"name":"20 kHz 至 50 kHz","range":"2,2 mV 至 3 mV","cmc":"6,3 µV"},{"name":"50 kHz 至 100 kHz","range":"2,2 mV 至 3 mV","cmc":"9,7 µV"},{"name":"100 kHz 至 300 kHz","range":"2,2 mV 至 3 mV","cmc":"16 µV"},{"name":"300 kHz 至 500 kHz","range":"2,2 mV 至 3 mV","cmc":"31 µV"},{"name":"500 kHz 至 1 MHz","range":"2,2 mV 至 3 mV","cmc":"36 µV"},{"name":"10 Hz 至 20 Hz","range":"3 mV 至 5 mV","cmc":"8,0 µV"},{"name":"20 Hz 至 40 Hz","range":"3 mV 至 5 mV","cmc":"6,4 µV"},{"name":"40 Hz 至 20 kHz","range":"3 mV 至 5 mV","cmc":"5,9 µV"},{"name":"20 kHz 至 50 kHz","range":"3 mV 至 5 mV","cmc":"7,1 µV"},{"name":"50 kHz 至 100 kHz","range":"3 mV 至 5 mV","cmc":"12 µV"},{"name":"100 kHz 至 300 kHz","range":"3 mV 至 5 mV","cmc":"18 µV"},{"name":"300 kHz 至 500 kHz","range":"3 mV 至 5 mV","cmc":"35 µV"},{"name":"500 kHz 至 1 MHz","range":"3 mV 至 5 mV","cmc":"43 µV"},{"name":"10 Hz 至 20 Hz","range":"5 mV 至 10 mV","cmc":"12 µV"},{"name":"20 Hz 至 40 Hz","range":"5 mV 至 10 mV","cmc":"8,0 µV"},{"name":"40 Hz 至 20 kHz","range":"5 mV 至 10 mV","cmc":"7,1 µV"},{"name":"20 kHz 至 50 kHz","range":"5 mV 至 10 mV","cmc":"9,4 µV"},{"name":"50 kHz 至 100 kHz","range":"5 mV 至 10 mV","cmc":"17 µV"},{"name":"100 kHz 至 300 kHz","range":"5 mV 至 10 mV","cmc":"25 µV"},{"name":"300 kHz 至 500 kHz","range":"5 mV 至 10 mV","cmc":"44 µV"},{"name":"500 kHz 至 1 MHz","range":"5 mV 至 10 mV","cmc":"61 µV"},{"name":"10 Hz 至 20 Hz","range":"10 mV 至 15 mV","cmc":"14 µV"},{"name":"20 Hz 至 40 Hz","range":"10 mV 至 15 mV","cmc":"8,8 µV"},{"name":"40 Hz 至 20 kHz","range":"10 mV 至 15 mV","cmc":"7,3 µV"},{"name":"20 kHz 至 50 kHz","range":"10 mV 至 15 mV","cmc":"12 µV"},{"name":"50 kHz 至 100 kHz","range":"10 mV 至 15 mV","cmc":"21 µV"},{"name":"100 kHz 至 300 kHz","range":"10 mV 至 15 mV","cmc":"31 µV"},{"name":"300 kHz 至 500 kHz","range":"10 mV 至 15 mV","cmc":"54 µV"},{"name":"500 kHz 至 1 MHz","range":"10 mV 至 15 mV","cmc":"78 µV"},{"name":"10 Hz 至 20 Hz","range":"15 mV 至 22 mV","cmc":"18 µV"},{"name":"20 Hz 至 40 Hz","range":"15 mV 至 22 mV","cmc":"10 µV"},{"name":"40 Hz 至 20 kHz","range":"15 mV 至 22 mV","cmc":"7,7 µV"},{"name":"20 kHz 至 50 kHz","range":"15 mV 至 22 mV","cmc":"14 µV"},{"name":"50 kHz 至 100 kHz","range":"15 mV 至 22 mV","cmc":"27 µV"},{"name":"100 kHz 至 300 kHz","range":"15 mV 至 22 mV","cmc":"39 µV"},{"name":"300 kHz 至 500 kHz","range":"15 mV 至 22 mV","cmc":"67 µV"},{"name":"500 kHz 至 1 MHz","range":"15 mV 至 22 mV","cmc":"0,11 mV"},{"name":"10 Hz 至 20 Hz","range":"22 mV 至 30 mV","cmc":"0,12 %"},{"name":"20 Hz 至 40 Hz","range":"22 mV 至 30 mV","cmc":"0,059 %"},{"name":"40 Hz 至 20 kHz","range":"22 mV 至 30 mV","cmc":"0,048 %"},{"name":"20 kHz 至 50 kHz","range":"22 mV 至 30 mV","cmc":"0,072 %"},{"name":"50 kHz 至 100 kHz","range":"22 mV 至 30 mV","cmc":"0,21 %"},{"name":"100 kHz 至 300 kHz","range":"22 mV 至 30 mV","cmc":"0,24 %"},{"name":"300 kHz 至 500 kHz","range":"22 mV 至 30 mV","cmc":"0,35 %"},{"name":"500 kHz 至 1 MHz","range":"22 mV 至 30 mV","cmc":"0,72 %"},{"name":"10 Hz 至 20 Hz","range":"30 mV 至 50 mV","cmc":"0,099 %"},{"name":"20 Hz 至 40 Hz","range":"30 mV 至 50 mV","cmc":"0,049 %"},{"name":"40 Hz 至 20 kHz","range":"30 mV 至 50 mV","cmc":"0,039 %"},{"name":"20 kHz 至 50 kHz","range":"30 mV 至 50 mV","cmc":"0,062 %"},{"name":"50 kHz 至 100 kHz","range":"30 mV 至 50 mV","cmc":"0,18 %"},{"name":"100 kHz 至 300 kHz","range":"30 mV 至 50 mV","cmc":"0,21 %"},{"name":"300 kHz 至 500 kHz","range":"30 mV 至 50 mV","cmc":"0,31 %"},{"name":"500 kHz 至 1 MHz","range":"30 mV 至 50 mV","cmc":"0,62 %"},{"name":"10 Hz 至 20 Hz","range":"50 mV 至 100 mV","cmc":"0,082 %"},{"name":"20 Hz 至 40 Hz","range":"50 mV 至 100 mV","cmc":"0,039 %"},{"name":"40 Hz 至 20 kHz","range":"50 mV 至 100 mV","cmc":"0,029 %"},{"name":"20 kHz 至 50 kHz","range":"50 mV 至 100 mV","cmc":"0,052 %"},{"name":"50 kHz 至 100 kHz","range":"50 mV 至 100 mV","cmc":"0,15 %"},{"name":"100 kHz 至 300 kHz","range":"50 mV 至 100 mV","cmc":"0,18 %"},{"name":"300 kHz 至 500 kHz","range":"50 mV 至 100 mV","cmc":"0,27 %"},{"name":"500 kHz 至 1 MHz","range":"50 mV 至 100 mV","cmc":"0,51 %"},{"name":"10 Hz 至 20 Hz","range":"100 mV 至 150 mV","cmc":"0,069 %"},{"name":"20 Hz 至 40 Hz","range":"100 mV 至 150 mV","cmc":"0,031 %"},{"name":"40 Hz 至 20 kHz","range":"100 mV 至 150 mV","cmc":"0,021 %"},{"name":"20 kHz 至 50 kHz","range":"100 mV 至 150 mV","cmc":"0,045 %"},{"name":"50 kHz 至 100 kHz","range":"100 mV 至 150 mV","cmc":"0,12 %"},{"name":"100 kHz 至 300 kHz","range":"100 mV 至 150 mV","cmc":"0,15 %"},{"name":"300 kHz 至 500 kHz","range":"100 mV 至 150 mV","cmc":"0,23 %"},{"name":"500 kHz 至 1 MHz","range":"100 mV 至 150 mV","cmc":"0,44 %"},{"name":"10 Hz 至 20 Hz","range":"150 mV 至 220 mV","cmc":"0,065 %"},{"name":"20 Hz 至 40 Hz","range":"150 mV 至 220 mV","cmc":"0,028 %"},{"name":"40 Hz 至 20 kHz","range":"150 mV 至 220 mV","cmc":"0,017 %"},{"name":"20 kHz 至 50 kHz","range":"150 mV 至 220 mV","cmc":"0,039 %"},{"name":"50 kHz 至 100 kHz","range":"150 mV 至 220 mV","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"150 mV 至 220 mV","cmc":"0,13 %"},{"name":"300 kHz 至 500 kHz","range":"150 mV 至 220 mV","cmc":"0,21 %"},{"name":"500 kHz 至 1 MHz","range":"150 mV 至 220 mV","cmc":"0,41 %"},{"name":"10 Hz 至 20 Hz","range":"220 mV 至 300 mV","cmc":"0,087 %"},{"name":"20 Hz 至 40 Hz","range":"220 mV 至 300 mV","cmc":"0,028 %"},{"name":"40 Hz 至 20 kHz","range":"220 mV 至 300 mV","cmc":"0,011 %"},{"name":"20 kHz 至 50 kHz","range":"220 mV 至 300 mV","cmc":"0,020 %"},{"name":"50 kHz 至 100 kHz","range":"220 mV 至 300 mV","cmc":"0,058 %"},{"name":"100 kHz 至 300 kHz","range":"220 mV 至 300 mV","cmc":"0,11 %"},{"name":"300 kHz 至 500 kHz","range":"220 mV 至 300 mV","cmc":"0,28 %"},{"name":"500 kHz 至 1 MHz","range":"220 mV 至 300 mV","cmc":"0,61 %"},{"name":"10 Hz 至 20 Hz","range":"300 mV 至 500 mV","cmc":"0,078 %"},{"name":"20 Hz 至 40 Hz","range":"300 mV 至 500 mV","cmc":"0,025 %"},{"name":"40 Hz 至 20 kHz","range":"300 mV 至 500 mV","cmc":"0,010 %"},{"name":"20 kHz 至 50 kHz","range":"300 mV 至 500 mV","cmc":"0,018 %"},{"name":"50 kHz 至 100 kHz","range":"300 mV 至 500 mV","cmc":"0,049 %"},{"name":"100 kHz 至 300 kHz","range":"300 mV 至 500 mV","cmc":"0,088 %"},{"name":"300 kHz 至 500 kHz","range":"300 mV 至 500 mV","cmc":"0,23 %"},{"name":"500 kHz 至 1 MHz","range":"300 mV 至 500 mV","cmc":"0,51 %"},{"name":"10 Hz 至 20 Hz","range":"500 mV 至 1 V","cmc":"0,067 %"},{"name":"20 Hz 至 40 Hz","range":"500 mV 至 1 V","cmc":"0,022 %"},{"name":"40 Hz 至 20 kHz","range":"500 mV 至 1 V","cmc":"0,0092 %"},{"name":"20 kHz 至 50 kHz","range":"500 mV 至 1 V","cmc":"0,016 %"},{"name":"50 kHz 至 100 kHz","range":"500 mV 至 1 V","cmc":"0,040 %"},{"name":"100 kHz 至 300 kHz","range":"500 mV 至 1 V","cmc":"0,071 %"},{"name":"300 kHz 至 500 kHz","range":"500 mV 至 1 V","cmc":"0,19 %"},{"name":"500 kHz 至 1 MHz","range":"500 mV 至 1 V","cmc":"0,40 %"},{"name":"10 Hz 至 20 Hz","range":"1 V 至 1,5 V","cmc":"0,059 %"},{"name":"20 Hz 至 40 Hz","range":"1 V 至 1,5 V","cmc":"0,019 %"},{"name":"40 Hz 至 20 kHz","range":"1 V 至 1,5 V","cmc":"0,0086 %"},{"name":"20 kHz 至 50 kHz","range":"1 V 至 1,5 V","cmc":"0,015 %"},{"name":"50 kHz 至 100 kHz","range":"1 V 至 1,5 V","cmc":"0,033 %"},{"name":"100 kHz 至 300 kHz","range":"1 V 至 1,5 V","cmc":"0,058 %"},{"name":"300 kHz 至 500 kHz","range":"1 V 至 1,5 V","cmc":"0,16 %"},{"name":"500 kHz 至 1 MHz","range":"1 V 至 1,5 V","cmc":"0,32 %"},{"name":"10 Hz 至 20 Hz","range":"1,5 V 至 2,2 V","cmc":"0,056 %"},{"name":"20 Hz 至 40 Hz","range":"1,5 V 至 2,2 V","cmc":"0,019 %"},{"name":"40 Hz 至 20 kHz","range":"1,5 V 至 2,2 V","cmc":"0,0084 %"},{"name":"20 kHz 至 50 kHz","range":"1,5 V 至 2,2 V","cmc":"0,014 %"},{"name":"50 kHz 至 100 kHz","range":"1,5 V 至 2,2 V","cmc":"0,030 %"},{"name":"100 kHz 至 300 kHz","range":"1,5 V 至 2,2 V","cmc":"0,053 %"},{"name":"300 kHz 至 500 kHz","range":"1,5 V 至 2,2 V","cmc":"0,15 %"},{"name":"500 kHz 至 1 MHz","range":"1,5 V 至 2,2 V","cmc":"0,29 %"},{"name":"10 Hz 至 20 Hz","range":"2,2 V 至 3 V","cmc":"0,087 %"},{"name":"20 Hz 至 40 Hz","range":"2,2 V 至 3 V","cmc":"0,028 %"},{"name":"40 Hz 至 20 kHz","range":"2,2 V 至 3 V","cmc":"0,011 %"},{"name":"20 kHz 至 50 kHz","range":"2,2 V 至 3 V","cmc":"0,020 %"},{"name":"50 kHz 至 100 kHz","range":"2,2 V 至 3 V","cmc":"0,042 %"},{"name":"100 kHz 至 300 kHz","range":"2,2 V 至 3 V","cmc":"0,12 %"},{"name":"300 kHz 至 500 kHz","range":"2,2 V 至 3 V","cmc":"0,33 %"},{"name":"500 kHz 至 1 MHz","range":"2,2 V 至 3 V","cmc":"0,67 %"},{"name":"10 Hz 至 20 Hz","range":"3 V 至 5 V","cmc":"0,078 %"},{"name":"20 Hz 至 40 Hz","range":"3 V 至 5 V","cmc":"0,025 %"},{"name":"40 Hz 至 20 kHz","range":"3 V 至 5 V","cmc":"0,099 %"},{"name":"20 kHz 至 50 kHz","range":"3 V 至 5 V","cmc":"0,018 %"},{"name":"50 kHz 至 100 kHz","range":"3 V 至 5 V","cmc":"0,030 %"},{"name":"100 kHz 至 300 kHz","range":"3 V 至 5 V","cmc":"0,11 %"},{"name":"300 kHz 至 500 kHz","range":"3 V 至 5 V","cmc":"0,28 %"},{"name":"500 kHz 至 1 MHz","range":"3 V 至 5 V","cmc":"0,56 %"},{"name":"10 Hz 至 20 Hz","range":"5 V 至 10 V","cmc":"0,067 %"},{"name":"20 Hz 至 40 Hz","range":"5 V 至 10 V","cmc":"0,022 %"},{"name":"40 Hz 至 20 kHz","range":"5 V 至 10 V","cmc":"0,0091 %"},{"name":"20 kHz 至 50 kHz","range":"5 V 至 10 V","cmc":"0,016 %"},{"name":"50 kHz 至 100 kHz","range":"5 V 至 10 V","cmc":"0,033 %"},{"name":"100 kHz 至 300 kHz","range":"5 V 至 10 V","cmc":"0,081 %"},{"name":"300 kHz 至 500 kHz","range":"5 V 至 10 V","cmc":"0,23 %"},{"name":"500 kHz 至 1 MHz","range":"5 V 至 10 V","cmc":"0,45 %"},{"name":"10 Hz 至 20 Hz","range":"10 V 至 15 V","cmc":"0,059 %"},{"name":"20 Hz 至 40 Hz","range":"10 V 至 15 V","cmc":"0,019 %"},{"name":"40 Hz 至 20 kHz","range":"10 V 至 15 V","cmc":"0,0086 %"},{"name":"20 kHz 至 50 kHz","range":"10 V 至 15 V","cmc":"0,014 %"},{"name":"50 kHz 至 100 kHz","range":"10 V 至 15 V","cmc":"0,029 %"},{"name":"100 kHz 至 300 kHz","range":"10 V 至 15 V","cmc":"0,066 %"},{"name":"300 kHz 至 500 kHz","range":"10 V 至 15 V","cmc":"0,19 %"},{"name":"500 kHz 至 1 MHz","range":"10 V 至 15 V","cmc":"0,37 %"},{"name":"10 Hz 至 20 Hz","range":"15 V 至 22 V","cmc":"0,056 %"},{"name":"20 Hz 至 40 Hz","range":"15 V 至 22 V","cmc":"0,019 %"},{"name":"40 Hz 至 20 kHz","range":"15 V 至 22 V","cmc":"0,087 %"},{"name":"20 kHz 至 50 kHz","range":"15 V 至 22 V","cmc":"0,014 %"},{"name":"50 kHz 至 100 kHz","range":"15 V 至 22 V","cmc":"0,029 %"},{"name":"100 kHz 至 300 kHz","range":"15 V 至 22 V","cmc":"0,061 %"},{"name":"300 kHz 至 500 kHz","range":"15 V 至 22 V","cmc":"0,18 %"},{"name":"500 kHz 至 1 MHz","range":"15 V 至 22 V","cmc":"0,34 %"},{"name":"10 Hz 至 20 Hz","range":"22 V 至 30 V","cmc":"0,087 %"},{"name":"20 Hz 至 40 Hz","range":"22 V 至 30 V","cmc":"0,028 %"},{"name":"40 Hz 至 20 kHz","range":"22 V 至 30 V","cmc":"0,013 %"},{"name":"20 kHz 至 50 kHz","range":"22 V 至 30 V","cmc":"0,039 %"},{"name":"50 kHz 至 100 kHz","range":"22 V 至 30 V","cmc":"0,087 %"},{"name":"10 Hz 至 20 Hz","range":"30 V 至 50 V","cmc":"0,078 %"},{"name":"20 Hz 至 40 Hz","range":"30 V 至 50 V","cmc":"0,025 %"},{"name":"40 Hz 至 20 kHz","range":"30 V 至 50 V","cmc":"0,012 %"},{"name":"20 kHz 至 50 kHz","range":"30 V 至 50 V","cmc":"0,034 %"},{"name":"50 kHz 至 100 kHz","range":"30 V 至 50 V","cmc":"0,078 %"},{"name":"10 Hz 至 20 Hz","range":"50 V 至 100 V","cmc":"0,067 %"},{"name":"20 Hz 至 40 Hz","range":"50 V 至 100 V","cmc":"0,022 %"},{"name":"40 Hz 至 20 kHz","range":"50 V 至 100 V","cmc":"0,011 %"},{"name":"20 kHz 至 50 kHz","range":"50 V 至 100 V","cmc":"0,030 %"},{"name":"50 kHz 至 100 kHz","range":"50 V 至 100 V","cmc":"0,067 %"},{"name":"10 Hz 至 20 Hz","range":"100 V 至 150 V","cmc":"0,059 %"},{"name":"20 Hz 至 40 Hz","range":"100 V 至 150 V","cmc":"0,019 %"},{"name":"40 Hz 至 20 kHz","range":"100 V 至 150 V","cmc":"0,010 %"},{"name":"20 kHz 至 50 kHz","range":"100 V 至 150 V","cmc":"0,026 %"},{"name":"50 kHz 至 100 kHz","range":"100 V 至 150 V","cmc":"0,059 %"},{"name":"10 Hz 至 20 Hz","range":"150 V 至 220 V","cmc":"0,057 %"},{"name":"20 Hz 至 40 Hz","range":"150 V 至 220 V","cmc":"0,019 %"},{"name":"40 Hz 至 20 kHz","range":"150 V 至 220 V","cmc":"0,011 %"},{"name":"20 kHz 至 50 kHz","range":"150 V 至 220 V","cmc":"0,027 %"},{"name":"50 kHz 至 100 kHz","range":"150 V 至 220 V","cmc":"0,065 %"},{"name":"10 Hz 至 50 Hz","range":"220 V 至 300 V","cmc":"0,030 %"},{"name":"50 Hz 至 1 kHz","range":"220 V 至 300 V","cmc":"0,012 %"},{"name":"1 kHz 至 10 kHz","range":"220 V 至 300 V","cmc":"0,026 %"},{"name":"10 kHz 至 30 kHz","range":"220 V 至 300 V","cmc":"0,042 %"},{"name":"10 Hz 至 50 Hz","range":"300 V 至 400 V","cmc":"0,030 %"},{"name":"50 Hz 至 1 kHz","range":"300 V 至 400 V","cmc":"0,012 %"},{"name":"1 kHz 至 10 kHz","range":"300 V 至 400 V","cmc":"0,026 %"},{"name":"10 kHz 至 30 kHz","range":"300 V 至 400 V","cmc":"0,042 %"},{"name":"10 Hz 至 50 Hz","range":"400 V 至 500 V","cmc":"0,028 %"},{"name":"50 Hz 至 1 kHz","range":"400 V 至 500 V","cmc":"0,012 %"},{"name":"1 kHz 至 10 kHz","range":"400 V 至 500 V","cmc":"0,025 %"},{"name":"10 kHz 至 30 kHz","range":"400 V 至 500 V","cmc":"0,045 %"},{"name":"10 Hz 至 50 Hz","range":"500 V 至 600 V","cmc":"0,027 %"},{"name":"50 Hz 至 1 kHz","range":"500 V 至 600 V","cmc":"0,011 %"},{"name":"1 kHz 至 10 kHz","range":"500 V 至 600 V","cmc":"0,023 %"},{"name":"10 kHz 至 30 kHz","range":"500 V 至 600 V","cmc":"0,053 %"},{"name":"10 Hz 至 50 Hz","range":"600 V 至 700 V","cmc":"0,028 %"},{"name":"50 Hz 至 1 kHz","range":"600 V 至 700 V","cmc":"0,012 %"},{"name":"1 kHz 至 10 kHz","range":"600 V 至 700 V","cmc":"0,025 %"},{"name":"10 kHz 至 30 kHz","range":"600 V 至 700 V","cmc":"0,068 %"},{"name":"10 Hz 至 50 Hz","range":"700 V 至 800 V","cmc":"0,030 %"},{"name":"50 Hz 至 1 kHz","range":"700 V 至 800 V","cmc":"0,011 %"},{"name":"1 kHz 至 10 kHz","range":"700 V 至 800 V","cmc":"0,028 %"},{"name":"10 kHz 至 30 kHz","range":"700 V 至 800 V","cmc":"0,089 %"},{"name":"10 Hz 至 50 Hz","range":"800 V 至 1050 V","cmc":"0,040 %"},{"name":"50 Hz 至 1 kHz","range":"800 V 至 1050 V","cmc":"0,010 %"},{"name":"1 kHz 至 10 kHz","range":"800 V 至 1050 V","cmc":"0,038 %"},{"name":"10 kHz 至 30 kHz","range":"800 V 至 1050 V","cmc":"0,17 %"}],"parameters_cs":[{"name":"10 Hz až 50 kHz","range":"0,22 mV až 0,5 mV","cmc":"4,9 µV"},{"name":"50 kHz až 100 kHz","range":"0,22 mV až 0,5 mV","cmc":"7,6 µV"},{"name":"10 Hz až 20 Hz","range":"0,5 mV až 1 mV","cmc":"5,5 µV"},{"name":"20 Hz až 40 Hz","range":"0,5 mV až 1 mV","cmc":"5,2 µV"},{"name":"40 Hz až 20 kHz","range":"0,5 mV až 1 mV","cmc":"5,1 µV"},{"name":"20 kHz až 50 kHz","range":"0,5 mV až 1 mV","cmc":"5,3 µV"},{"name":"50 kHz až 100 kHz","range":"0,5 mV až 1 mV","cmc":"8,5 µV"},{"name":"10 Hz až 20 Hz","range":"1 mV až 2,2 mV","cmc":"5,9 µV"},{"name":"20 Hz až 20 kHz","range":"1 mV až 2,2 mV","cmc":"5,2 µV"},{"name":"20 kHz až 50 kHz","range":"1 mV až 2,2 mV","cmc":"5,6 µV"},{"name":"50 kHz až 100 kHz","range":"1 mV až 2,2 mV","cmc":"9,1 µV"},{"name":"100 kHz až 300 kHz","range":"1 mV až 2,2 mV","cmc":"16 µV"},{"name":"300 kHz až 500 kHz","range":"1 mV až 2,2 mV","cmc":"30 µV"},{"name":"500 kHz až 1 MHz","range":"1 mV až 2,2 mV","cmc":"34 µV"},{"name":"10 Hz až 20 Hz","range":"2,2 mV až 3 mV","cmc":"6,8 µV"},{"name":"20 Hz až 40 Hz","range":"2,2 mV až 3 mV","cmc":"5,8 µV"},{"name":"40 Hz až 20 kHz","range":"2,2 mV až 3 mV","cmc":"5,5 µV"},{"name":"20 kHz až 50 kHz","range":"2,2 mV až 3 mV","cmc":"6,3 µV"},{"name":"50 kHz až 100 kHz","range":"2,2 mV až 3 mV","cmc":"9,7 µV"},{"name":"100 kHz až 300 kHz","range":"2,2 mV až 3 mV","cmc":"16 µV"},{"name":"300 kHz až 500 kHz","range":"2,2 mV až 3 mV","cmc":"31 µV"},{"name":"500 kHz až 1 MHz","range":"2,2 mV až 3 mV","cmc":"36 µV"},{"name":"10 Hz až 20 Hz","range":"3 mV až 5 mV","cmc":"8,0 µV"},{"name":"20 Hz až 40 Hz","range":"3 mV až 5 mV","cmc":"6,4 µV"},{"name":"40 Hz až 20 kHz","range":"3 mV až 5 mV","cmc":"5,9 µV"},{"name":"20 kHz až 50 kHz","range":"3 mV až 5 mV","cmc":"7,1 µV"},{"name":"50 kHz až 100 kHz","range":"3 mV až 5 mV","cmc":"12 µV"},{"name":"100 kHz až 300 kHz","range":"3 mV až 5 mV","cmc":"18 µV"},{"name":"300 kHz až 500 kHz","range":"3 mV až 5 mV","cmc":"35 µV"},{"name":"500 kHz až 1 MHz","range":"3 mV až 5 mV","cmc":"43 µV"},{"name":"10 Hz až 20 Hz","range":"5 mV až 10 mV","cmc":"12 µV"},{"name":"20 Hz až 40 Hz","range":"5 mV až 10 mV","cmc":"8,0 µV"},{"name":"40 Hz až 20 kHz","range":"5 mV až 10 mV","cmc":"7,1 µV"},{"name":"20 kHz až 50 kHz","range":"5 mV až 10 mV","cmc":"9,4 µV"},{"name":"50 kHz až 100 kHz","range":"5 mV až 10 mV","cmc":"17 µV"},{"name":"100 kHz až 300 kHz","range":"5 mV až 10 mV","cmc":"25 µV"},{"name":"300 kHz až 500 kHz","range":"5 mV až 10 mV","cmc":"44 µV"},{"name":"500 kHz až 1 MHz","range":"5 mV až 10 mV","cmc":"61 µV"},{"name":"10 Hz až 20 Hz","range":"10 mV až 15 mV","cmc":"14 µV"},{"name":"20 Hz až 40 Hz","range":"10 mV až 15 mV","cmc":"8,8 µV"},{"name":"40 Hz až 20 kHz","range":"10 mV až 15 mV","cmc":"7,3 µV"},{"name":"20 kHz až 50 kHz","range":"10 mV až 15 mV","cmc":"12 µV"},{"name":"50 kHz až 100 kHz","range":"10 mV až 15 mV","cmc":"21 µV"},{"name":"100 kHz až 300 kHz","range":"10 mV až 15 mV","cmc":"31 µV"},{"name":"300 kHz až 500 kHz","range":"10 mV až 15 mV","cmc":"54 µV"},{"name":"500 kHz až 1 MHz","range":"10 mV až 15 mV","cmc":"78 µV"},{"name":"10 Hz až 20 Hz","range":"15 mV až 22 mV","cmc":"18 µV"},{"name":"20 Hz až 40 Hz","range":"15 mV až 22 mV","cmc":"10 µV"},{"name":"40 Hz až 20 kHz","range":"15 mV až 22 mV","cmc":"7,7 µV"},{"name":"20 kHz až 50 kHz","range":"15 mV až 22 mV","cmc":"14 µV"},{"name":"50 kHz až 100 kHz","range":"15 mV až 22 mV","cmc":"27 µV"},{"name":"100 kHz až 300 kHz","range":"15 mV až 22 mV","cmc":"39 µV"},{"name":"300 kHz až 500 kHz","range":"15 mV až 22 mV","cmc":"67 µV"},{"name":"500 kHz až 1 MHz","range":"15 mV až 22 mV","cmc":"0,11 mV"},{"name":"10 Hz až 20 Hz","range":"22 mV až 30 mV","cmc":"0,12 %"},{"name":"20 Hz až 40 Hz","range":"22 mV až 30 mV","cmc":"0,059 %"},{"name":"40 Hz až 20 kHz","range":"22 mV až 30 mV","cmc":"0,048 %"},{"name":"20 kHz až 50 kHz","range":"22 mV až 30 mV","cmc":"0,072 %"},{"name":"50 kHz až 100 kHz","range":"22 mV až 30 mV","cmc":"0,21 %"},{"name":"100 kHz až 300 kHz","range":"22 mV až 30 mV","cmc":"0,24 %"},{"name":"300 kHz až 500 kHz","range":"22 mV až 30 mV","cmc":"0,35 %"},{"name":"500 kHz až 1 MHz","range":"22 mV až 30 mV","cmc":"0,72 %"},{"name":"10 Hz až 20 Hz","range":"30 mV až 50 mV","cmc":"0,099 %"},{"name":"20 Hz až 40 Hz","range":"30 mV až 50 mV","cmc":"0,049 %"},{"name":"40 Hz až 20 kHz","range":"30 mV až 50 mV","cmc":"0,039 %"},{"name":"20 kHz až 50 kHz","range":"30 mV až 50 mV","cmc":"0,062 %"},{"name":"50 kHz až 100 kHz","range":"30 mV až 50 mV","cmc":"0,18 %"},{"name":"100 kHz až 300 kHz","range":"30 mV až 50 mV","cmc":"0,21 %"},{"name":"300 kHz až 500 kHz","range":"30 mV až 50 mV","cmc":"0,31 %"},{"name":"500 kHz až 1 MHz","range":"30 mV až 50 mV","cmc":"0,62 %"},{"name":"10 Hz až 20 Hz","range":"50 mV až 100 mV","cmc":"0,082 %"},{"name":"20 Hz až 40 Hz","range":"50 mV až 100 mV","cmc":"0,039 %"},{"name":"40 Hz až 20 kHz","range":"50 mV až 100 mV","cmc":"0,029 %"},{"name":"20 kHz až 50 kHz","range":"50 mV až 100 mV","cmc":"0,052 %"},{"name":"50 kHz až 100 kHz","range":"50 mV až 100 mV","cmc":"0,15 %"},{"name":"100 kHz až 300 kHz","range":"50 mV až 100 mV","cmc":"0,18 %"},{"name":"300 kHz až 500 kHz","range":"50 mV až 100 mV","cmc":"0,27 %"},{"name":"500 kHz až 1 MHz","range":"50 mV až 100 mV","cmc":"0,51 %"},{"name":"10 Hz až 20 Hz","range":"100 mV až 150 mV","cmc":"0,069 %"},{"name":"20 Hz až 40 Hz","range":"100 mV až 150 mV","cmc":"0,031 %"},{"name":"40 Hz až 20 kHz","range":"100 mV až 150 mV","cmc":"0,021 %"},{"name":"20 kHz až 50 kHz","range":"100 mV až 150 mV","cmc":"0,045 %"},{"name":"50 kHz až 100 kHz","range":"100 mV až 150 mV","cmc":"0,12 %"},{"name":"100 kHz až 300 kHz","range":"100 mV až 150 mV","cmc":"0,15 %"},{"name":"300 kHz až 500 kHz","range":"100 mV až 150 mV","cmc":"0,23 %"},{"name":"500 kHz až 1 MHz","range":"100 mV až 150 mV","cmc":"0,44 %"},{"name":"10 Hz až 20 Hz","range":"150 mV až 220 mV","cmc":"0,065 %"},{"name":"20 Hz až 40 Hz","range":"150 mV až 220 mV","cmc":"0,028 %"},{"name":"40 Hz až 20 kHz","range":"150 mV až 220 mV","cmc":"0,017 %"},{"name":"20 kHz až 50 kHz","range":"150 mV až 220 mV","cmc":"0,039 %"},{"name":"50 kHz až 100 kHz","range":"150 mV až 220 mV","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"150 mV až 220 mV","cmc":"0,13 %"},{"name":"300 kHz až 500 kHz","range":"150 mV až 220 mV","cmc":"0,21 %"},{"name":"500 kHz až 1 MHz","range":"150 mV až 220 mV","cmc":"0,41 %"},{"name":"10 Hz až 20 Hz","range":"220 mV až 300 mV","cmc":"0,087 %"},{"name":"20 Hz až 40 Hz","range":"220 mV až 300 mV","cmc":"0,028 %"},{"name":"40 Hz až 20 kHz","range":"220 mV až 300 mV","cmc":"0,011 %"},{"name":"20 kHz až 50 kHz","range":"220 mV až 300 mV","cmc":"0,020 %"},{"name":"50 kHz až 100 kHz","range":"220 mV až 300 mV","cmc":"0,058 %"},{"name":"100 kHz až 300 kHz","range":"220 mV až 300 mV","cmc":"0,11 %"},{"name":"300 kHz až 500 kHz","range":"220 mV až 300 mV","cmc":"0,28 %"},{"name":"500 kHz až 1 MHz","range":"220 mV až 300 mV","cmc":"0,61 %"},{"name":"10 Hz až 20 Hz","range":"300 mV až 500 mV","cmc":"0,078 %"},{"name":"20 Hz až 40 Hz","range":"300 mV až 500 mV","cmc":"0,025 %"},{"name":"40 Hz až 20 kHz","range":"300 mV až 500 mV","cmc":"0,010 %"},{"name":"20 kHz až 50 kHz","range":"300 mV až 500 mV","cmc":"0,018 %"},{"name":"50 kHz až 100 kHz","range":"300 mV až 500 mV","cmc":"0,049 %"},{"name":"100 kHz až 300 kHz","range":"300 mV až 500 mV","cmc":"0,088 %"},{"name":"300 kHz až 500 kHz","range":"300 mV až 500 mV","cmc":"0,23 %"},{"name":"500 kHz až 1 MHz","range":"300 mV až 500 mV","cmc":"0,51 %"},{"name":"10 Hz až 20 Hz","range":"500 mV až 1 V","cmc":"0,067 %"},{"name":"20 Hz až 40 Hz","range":"500 mV až 1 V","cmc":"0,022 %"},{"name":"40 Hz až 20 kHz","range":"500 mV až 1 V","cmc":"0,0092 %"},{"name":"20 kHz až 50 kHz","range":"500 mV až 1 V","cmc":"0,016 %"},{"name":"50 kHz až 100 kHz","range":"500 mV až 1 V","cmc":"0,040 %"},{"name":"100 kHz až 300 kHz","range":"500 mV až 1 V","cmc":"0,071 %"},{"name":"300 kHz až 500 kHz","range":"500 mV až 1 V","cmc":"0,19 %"},{"name":"500 kHz až 1 MHz","range":"500 mV až 1 V","cmc":"0,40 %"},{"name":"10 Hz až 20 Hz","range":"1 V až 1,5 V","cmc":"0,059 %"},{"name":"20 Hz až 40 Hz","range":"1 V až 1,5 V","cmc":"0,019 %"},{"name":"40 Hz až 20 kHz","range":"1 V až 1,5 V","cmc":"0,0086 %"},{"name":"20 kHz až 50 kHz","range":"1 V až 1,5 V","cmc":"0,015 %"},{"name":"50 kHz až 100 kHz","range":"1 V až 1,5 V","cmc":"0,033 %"},{"name":"100 kHz až 300 kHz","range":"1 V až 1,5 V","cmc":"0,058 %"},{"name":"300 kHz až 500 kHz","range":"1 V až 1,5 V","cmc":"0,16 %"},{"name":"500 kHz až 1 MHz","range":"1 V až 1,5 V","cmc":"0,32 %"},{"name":"10 Hz až 20 Hz","range":"1,5 V až 2,2 V","cmc":"0,056 %"},{"name":"20 Hz až 40 Hz","range":"1,5 V až 2,2 V","cmc":"0,019 %"},{"name":"40 Hz až 20 kHz","range":"1,5 V až 2,2 V","cmc":"0,0084 %"},{"name":"20 kHz až 50 kHz","range":"1,5 V až 2,2 V","cmc":"0,014 %"},{"name":"50 kHz až 100 kHz","range":"1,5 V až 2,2 V","cmc":"0,030 %"},{"name":"100 kHz až 300 kHz","range":"1,5 V až 2,2 V","cmc":"0,053 %"},{"name":"300 kHz až 500 kHz","range":"1,5 V až 2,2 V","cmc":"0,15 %"},{"name":"500 kHz až 1 MHz","range":"1,5 V až 2,2 V","cmc":"0,29 %"},{"name":"10 Hz až 20 Hz","range":"2,2 V až 3 V","cmc":"0,087 %"},{"name":"20 Hz až 40 Hz","range":"2,2 V až 3 V","cmc":"0,028 %"},{"name":"40 Hz až 20 kHz","range":"2,2 V až 3 V","cmc":"0,011 %"},{"name":"20 kHz až 50 kHz","range":"2,2 V až 3 V","cmc":"0,020 %"},{"name":"50 kHz až 100 kHz","range":"2,2 V až 3 V","cmc":"0,042 %"},{"name":"100 kHz až 300 kHz","range":"2,2 V až 3 V","cmc":"0,12 %"},{"name":"300 kHz až 500 kHz","range":"2,2 V až 3 V","cmc":"0,33 %"},{"name":"500 kHz až 1 MHz","range":"2,2 V až 3 V","cmc":"0,67 %"},{"name":"10 Hz až 20 Hz","range":"3 V až 5 V","cmc":"0,078 %"},{"name":"20 Hz až 40 Hz","range":"3 V až 5 V","cmc":"0,025 %"},{"name":"40 Hz až 20 kHz","range":"3 V až 5 V","cmc":"0,099 %"},{"name":"20 kHz až 50 kHz","range":"3 V až 5 V","cmc":"0,018 %"},{"name":"50 kHz až 100 kHz","range":"3 V až 5 V","cmc":"0,030 %"},{"name":"100 kHz až 300 kHz","range":"3 V až 5 V","cmc":"0,11 %"},{"name":"300 kHz až 500 kHz","range":"3 V až 5 V","cmc":"0,28 %"},{"name":"500 kHz až 1 MHz","range":"3 V až 5 V","cmc":"0,56 %"},{"name":"10 Hz až 20 Hz","range":"5 V až 10 V","cmc":"0,067 %"},{"name":"20 Hz až 40 Hz","range":"5 V až 10 V","cmc":"0,022 %"},{"name":"40 Hz až 20 kHz","range":"5 V až 10 V","cmc":"0,0091 %"},{"name":"20 kHz až 50 kHz","range":"5 V až 10 V","cmc":"0,016 %"},{"name":"50 kHz až 100 kHz","range":"5 V až 10 V","cmc":"0,033 %"},{"name":"100 kHz až 300 kHz","range":"5 V až 10 V","cmc":"0,081 %"},{"name":"300 kHz až 500 kHz","range":"5 V až 10 V","cmc":"0,23 %"},{"name":"500 kHz až 1 MHz","range":"5 V až 10 V","cmc":"0,45 %"},{"name":"10 Hz až 20 Hz","range":"10 V až 15 V","cmc":"0,059 %"},{"name":"20 Hz až 40 Hz","range":"10 V až 15 V","cmc":"0,019 %"},{"name":"40 Hz až 20 kHz","range":"10 V až 15 V","cmc":"0,0086 %"},{"name":"20 kHz až 50 kHz","range":"10 V až 15 V","cmc":"0,014 %"},{"name":"50 kHz až 100 kHz","range":"10 V až 15 V","cmc":"0,029 %"},{"name":"100 kHz až 300 kHz","range":"10 V až 15 V","cmc":"0,066 %"},{"name":"300 kHz až 500 kHz","range":"10 V až 15 V","cmc":"0,19 %"},{"name":"500 kHz až 1 MHz","range":"10 V až 15 V","cmc":"0,37 %"},{"name":"10 Hz až 20 Hz","range":"15 V až 22 V","cmc":"0,056 %"},{"name":"20 Hz až 40 Hz","range":"15 V až 22 V","cmc":"0,019 %"},{"name":"40 Hz až 20 kHz","range":"15 V až 22 V","cmc":"0,087 %"},{"name":"20 kHz až 50 kHz","range":"15 V až 22 V","cmc":"0,014 %"},{"name":"50 kHz až 100 kHz","range":"15 V až 22 V","cmc":"0,029 %"},{"name":"100 kHz až 300 kHz","range":"15 V až 22 V","cmc":"0,061 %"},{"name":"300 kHz až 500 kHz","range":"15 V až 22 V","cmc":"0,18 %"},{"name":"500 kHz až 1 MHz","range":"15 V až 22 V","cmc":"0,34 %"},{"name":"10 Hz až 20 Hz","range":"22 V až 30 V","cmc":"0,087 %"},{"name":"20 Hz až 40 Hz","range":"22 V až 30 V","cmc":"0,028 %"},{"name":"40 Hz až 20 kHz","range":"22 V až 30 V","cmc":"0,013 %"},{"name":"20 kHz až 50 kHz","range":"22 V až 30 V","cmc":"0,039 %"},{"name":"50 kHz až 100 kHz","range":"22 V až 30 V","cmc":"0,087 %"},{"name":"10 Hz až 20 Hz","range":"30 V až 50 V","cmc":"0,078 %"},{"name":"20 Hz až 40 Hz","range":"30 V až 50 V","cmc":"0,025 %"},{"name":"40 Hz až 20 kHz","range":"30 V až 50 V","cmc":"0,012 %"},{"name":"20 kHz až 50 kHz","range":"30 V až 50 V","cmc":"0,034 %"},{"name":"50 kHz až 100 kHz","range":"30 V až 50 V","cmc":"0,078 %"},{"name":"10 Hz až 20 Hz","range":"50 V až 100 V","cmc":"0,067 %"},{"name":"20 Hz až 40 Hz","range":"50 V až 100 V","cmc":"0,022 %"},{"name":"40 Hz až 20 kHz","range":"50 V až 100 V","cmc":"0,011 %"},{"name":"20 kHz až 50 kHz","range":"50 V až 100 V","cmc":"0,030 %"},{"name":"50 kHz až 100 kHz","range":"50 V až 100 V","cmc":"0,067 %"},{"name":"10 Hz až 20 Hz","range":"100 V až 150 V","cmc":"0,059 %"},{"name":"20 Hz až 40 Hz","range":"100 V až 150 V","cmc":"0,019 %"},{"name":"40 Hz až 20 kHz","range":"100 V až 150 V","cmc":"0,010 %"},{"name":"20 kHz až 50 kHz","range":"100 V až 150 V","cmc":"0,026 %"},{"name":"50 kHz až 100 kHz","range":"100 V až 150 V","cmc":"0,059 %"},{"name":"10 Hz až 20 Hz","range":"150 V až 220 V","cmc":"0,057 %"},{"name":"20 Hz až 40 Hz","range":"150 V až 220 V","cmc":"0,019 %"},{"name":"40 Hz až 20 kHz","range":"150 V až 220 V","cmc":"0,011 %"},{"name":"20 kHz až 50 kHz","range":"150 V až 220 V","cmc":"0,027 %"},{"name":"50 kHz až 100 kHz","range":"150 V až 220 V","cmc":"0,065 %"},{"name":"10 Hz až 50 Hz","range":"220 V až 300 V","cmc":"0,030 %"},{"name":"50 Hz až 1 kHz","range":"220 V až 300 V","cmc":"0,012 %"},{"name":"1 kHz až 10 kHz","range":"220 V až 300 V","cmc":"0,026 %"},{"name":"10 kHz až 30 kHz","range":"220 V až 300 V","cmc":"0,042 %"},{"name":"10 Hz až 50 Hz","range":"300 V až 400 V","cmc":"0,030 %"},{"name":"50 Hz až 1 kHz","range":"300 V až 400 V","cmc":"0,012 %"},{"name":"1 kHz až 10 kHz","range":"300 V až 400 V","cmc":"0,026 %"},{"name":"10 kHz až 30 kHz","range":"300 V až 400 V","cmc":"0,042 %"},{"name":"10 Hz až 50 Hz","range":"400 V až 500 V","cmc":"0,028 %"},{"name":"50 Hz až 1 kHz","range":"400 V až 500 V","cmc":"0,012 %"},{"name":"1 kHz až 10 kHz","range":"400 V až 500 V","cmc":"0,025 %"},{"name":"10 kHz až 30 kHz","range":"400 V až 500 V","cmc":"0,045 %"},{"name":"10 Hz až 50 Hz","range":"500 V až 600 V","cmc":"0,027 %"},{"name":"50 Hz až 1 kHz","range":"500 V až 600 V","cmc":"0,011 %"},{"name":"1 kHz až 10 kHz","range":"500 V až 600 V","cmc":"0,023 %"},{"name":"10 kHz až 30 kHz","range":"500 V až 600 V","cmc":"0,053 %"},{"name":"10 Hz až 50 Hz","range":"600 V až 700 V","cmc":"0,028 %"},{"name":"50 Hz až 1 kHz","range":"600 V až 700 V","cmc":"0,012 %"},{"name":"1 kHz až 10 kHz","range":"600 V až 700 V","cmc":"0,025 %"},{"name":"10 kHz až 30 kHz","range":"600 V až 700 V","cmc":"0,068 %"},{"name":"10 Hz až 50 Hz","range":"700 V až 800 V","cmc":"0,030 %"},{"name":"50 Hz až 1 kHz","range":"700 V až 800 V","cmc":"0,011 %"},{"name":"1 kHz až 10 kHz","range":"700 V až 800 V","cmc":"0,028 %"},{"name":"10 kHz až 30 kHz","range":"700 V až 800 V","cmc":"0,089 %"},{"name":"10 Hz až 50 Hz","range":"800 V až 1050 V","cmc":"0,040 %"},{"name":"50 Hz až 1 kHz","range":"800 V až 1050 V","cmc":"0,010 %"},{"name":"1 kHz až 10 kHz","range":"800 V až 1050 V","cmc":"0,038 %"},{"name":"10 kHz až 30 kHz","range":"800 V až 1050 V","cmc":"0,17 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 50 kHz od 0,22 mV do 0,5 mV CMC 4,9 µV\n50 kHz do 100 kHz od 0,22 mV do 0,5 mV CMC 7,6 µV\n10 Hz do 20 Hz od 0,5 mV do 1 mV CMC 5,5 µV\n20 Hz do 40 Hz od 0,5 mV do 1 mV CMC 5,2 µV\n40 Hz do 20 kHz od 0,5 mV do 1 mV CMC 5,1 µV\n20 kHz do 50 kHz od 0,5 mV do 1 mV CMC 5,3 µV\n50 kHz do 100 kHz od 0,5 mV do 1 mV CMC 8,5 µV\n10 Hz do 20 Hz od 1 mV do 2,2 mV CMC 5,9 µV\n20 Hz do 20 kHz od 1 mV do 2,2 mV CMC 5,2 µV\n20 kHz do 50 kHz od 1 mV do 2,2 mV CMC 5,6 µV\n50 kHz do 100 kHz od 1 mV do 2,2 mV CMC 9,1 µV\n100 kHz do 300 kHz od 1 mV do 2,2 mV CMC 16 µV\n300 kHz do 500 kHz od 1 mV do 2,2 mV CMC 30 µV\n500 kHz do 1 MHz od 1 mV do 2,2 mV CMC 34 µV\n10 Hz do 20 Hz od 2,2 mV do 3 mV CMC 6,8 µV\n20 Hz do 40 Hz od 2,2 mV do 3 mV CMC 5,8 µV\n40 Hz do 20 kHz od 2,2 mV do 3 mV CMC 5,5 µV\n20 kHz do 50 kHz od 2,2 mV do 3 mV CMC 6,3 µV\n50 kHz do 100 kHz od 2,2 mV do 3 mV CMC 9,7 µV\n100 kHz do 300 kHz od 2,2 mV do 3 mV CMC 16 µV\n300 kHz do 500 kHz od 2,2 mV do 3 mV CMC 31 µV\n500 kHz do 1 MHz od 2,2 mV do 3 mV CMC 36 µV\n10 Hz do 20 Hz od 3 mV do 5 mV CMC 8,0 µV\n20 Hz do 40 Hz od 3 mV do 5 mV CMC 6,4 µV\n40 Hz do 20 kHz od 3 mV do 5 mV CMC 5,9 µV\n20 kHz do 50 kHz od 3 mV do 5 mV CMC 7,1 µV\n50 kHz do 100 kHz od 3 mV do 5 mV CMC 12 µV\n100 kHz do 300 kHz od 3 mV do 5 mV CMC 18 µV\n300 kHz do 500 kHz od 3 mV do 5 mV CMC 35 µV\n500 kHz do 1 MHz od 3 mV do 5 mV CMC 43 µV\n10 Hz do 20 Hz od 5 mV do 10 mV CMC 12 µV\n20 Hz do 40 Hz od 5 mV do 10 mV CMC 8,0 µV\n40 Hz do 20 kHz od 5 mV do 10 mV CMC 7,1 µV\n20 kHz do 50 kHz od 5 mV do 10 mV CMC 9,4 µV\n50 kHz do 100 kHz od 5 mV do 10 mV CMC 17 µV\n100 kHz do 300 kHz od 5 mV do 10 mV CMC 25 µV\n300 kHz do 500 kHz od 5 mV do 10 mV CMC 44 µV\n500 kHz do 1 MHz od 5 mV do 10 mV CMC 61 µV\n10 Hz do 20 Hz od 10 mV do 15 mV CMC 14 µV\n20 Hz do 40 Hz od 10 mV do 15 mV CMC 8,8 µV\n40 Hz do 20 kHz od 10 mV do 15 mV CMC 7,3 µV\n20 kHz do 50 kHz od 10 mV do 15 mV CMC 12 µV\n50 kHz do 100 kHz od 10 mV do 15 mV CMC 21 µV\n100 kHz do 300 kHz od 10 mV do 15 mV CMC 31 µV\n300 kHz do 500 kHz od 10 mV do 15 mV CMC 54 µV\n500 kHz do 1 MHz od 10 mV do 15 mV CMC 78 µV\n10 Hz do 20 Hz od 15 mV do 22 mV CMC 18 µV\n20 Hz do 40 Hz od 15 mV do 22 mV CMC 10 µV\n40 Hz do 20 kHz od 15 mV do 22 mV CMC 7,7 µV\n20 kHz do 50 kHz od 15 mV do 22 mV CMC 14 µV\n50 kHz do 100 kHz od 15 mV do 22 mV CMC 27 µV\n100 kHz do 300 kHz od 15 mV do 22 mV CMC 39 µV\n300 kHz do 500 kHz od 15 mV do 22 mV CMC 67 µV\n500 kHz do 1 MHz od 15 mV do 22 mV CMC 0,11 mV\n10 Hz do 20 Hz od 22 mV do 30 mV CMC 0,12 %\n20 Hz do 40 Hz od 22 mV do 30 mV CMC 0,059 %\n40 Hz do 20 kHz od 22 mV do 30 mV CMC 0,048 %\n20 kHz do 50 kHz od 22 mV do 30 mV CMC 0,072 %\n50 kHz do 100 kHz od 22 mV do 30 mV CMC 0,21 %\n100 kHz do 300 kHz od 22 mV do 30 mV CMC 0,24 %\n300 kHz do 500 kHz od 22 mV do 30 mV CMC 0,35 %\n500 kHz do 1 MHz od 22 mV do 30 mV CMC 0,72 %\n10 Hz do 20 Hz od 30 mV do 50 mV CMC 0,099 %\n20 Hz do 40 Hz od 30 mV do 50 mV CMC 0,049 %\n40 Hz do 20 kHz od 30 mV do 50 mV CMC 0,039 %\n20 kHz do 50 kHz od 30 mV do 50 mV CMC 0,062 %\n50 kHz do 100 kHz od 30 mV do 50 mV CMC 0,18 %\n100 kHz do 300 kHz od 30 mV do 50 mV CMC 0,21 %\n300 kHz do 500 kHz od 30 mV do 50 mV CMC 0,31 %\n500 kHz do 1 MHz od 30 mV do 50 mV CMC 0,62 %\n10 Hz do 20 Hz od 50 mV do 100 mV CMC 0,082 %\n20 Hz do 40 Hz od 50 mV do 100 mV CMC 0,039 %\n40 Hz do 20 kHz od 50 mV do 100 mV CMC 0,029 %\n20 kHz do 50 kHz od 50 mV do 100 mV CMC 0,052 %\n50 kHz do 100 kHz od 50 mV do 100 mV CMC 0,15 %\n100 kHz do 300 kHz od 50 mV do 100 mV CMC 0,18 %\n300 kHz do 500 kHz od 50 mV do 100 mV CMC 0,27 %\n500 kHz do 1 MHz od 50 mV do 100 mV CMC 0,51 %\n10 Hz do 20 Hz od 100 mV do 150 mV CMC 0,069 %\n20 Hz do 40 Hz od 100 mV do 150 mV CMC 0,031 %\n40 Hz do 20 kHz od 100 mV do 150 mV CMC 0,021 %\n20 kHz do 50 kHz od 100 mV do 150 mV CMC 0,045 %\n50 kHz do 100 kHz od 100 mV do 150 mV CMC 0,12 %\n100 kHz do 300 kHz od 100 mV do 150 mV CMC 0,15 %\n300 kHz do 500 kHz od 100 mV do 150 mV CMC 0,23 %\n500 kHz do 1 MHz od 100 mV do 150 mV CMC 0,44 %\n10 Hz do 20 Hz od 150 mV do 220 mV CMC 0,065 %\n20 Hz do 40 Hz od 150 mV do 220 mV CMC 0,028 %\n40 Hz do 20 kHz od 150 mV do 220 mV CMC 0,017 %\n20 kHz do 50 kHz od 150 mV do 220 mV CMC 0,039 %\n50 kHz do 100 kHz od 150 mV do 220 mV CMC 0,11 %\n100 kHz do 300 kHz od 150 mV do 220 mV CMC 0,13 %\n300 kHz do 500 kHz od 150 mV do 220 mV CMC 0,21 %\n500 kHz do 1 MHz od 150 mV do 220 mV CMC 0,41 %\n10 Hz do 20 Hz od 220 mV do 300 mV CMC 0,087 %\n20 Hz do 40 Hz od 220 mV do 300 mV CMC 0,028 %\n40 Hz do 20 kHz od 220 mV do 300 mV CMC 0,011 %\n20 kHz do 50 kHz od 220 mV do 300 mV CMC 0,020 %\n50 kHz do 100 kHz od 220 mV do 300 mV CMC 0,058 %\n100 kHz do 300 kHz od 220 mV do 300 mV CMC 0,11 %\n300 kHz do 500 kHz od 220 mV do 300 mV CMC 0,28 %\n500 kHz do 1 MHz od 220 mV do 300 mV CMC 0,61 %\n10 Hz do 20 Hz od 300 mV do 500 mV CMC 0,078 %\n20 Hz do 40 Hz od 300 mV do 500 mV CMC 0,025 %\n40 Hz do 20 kHz od 300 mV do 500 mV CMC 0,010 %\n20 kHz do 50 kHz od 300 mV do 500 mV CMC 0,018 %\n50 kHz do 100 kHz od 300 mV do 500 mV CMC 0,049 %\n100 kHz do 300 kHz od 300 mV do 500 mV CMC 0,088 %\n300 kHz do 500 kHz od 300 mV do 500 mV CMC 0,23 %\n500 kHz do 1 MHz od 300 mV do 500 mV CMC 0,51 %\n10 Hz do 20 Hz od 500 mV do 1 V CMC 0,067 %\n20 Hz do 40 Hz od 500 mV do 1 V CMC 0,022 %\n40 Hz do 20 kHz od 500 mV do 1 V CMC 0,0092 %\n20 kHz do 50 kHz od 500 mV do 1 V CMC 0,016 %\n50 kHz do 100 kHz od 500 mV do 1 V CMC 0,040 %\n100 kHz do 300 kHz od 500 mV do 1 V CMC 0,071 %\n300 kHz do 500 kHz od 500 mV do 1 V CMC 0,19 %\n500 kHz do 1 MHz od 500 mV do 1 V CMC 0,40 %\n10 Hz do 20 Hz od 1 V do 1,5 V CMC 0,059 %\n20 Hz do 40 Hz od 1 V do 1,5 V CMC 0,019 %\n40 Hz do 20 kHz od 1 V do 1,5 V CMC 0,0086 %\n20 kHz do 50 kHz od 1 V do 1,5 V CMC 0,015 %\n50 kHz do 100 kHz od 1 V do 1,5 V CMC 0,033 %\n100 kHz do 300 kHz od 1 V do 1,5 V CMC 0,058 %\n300 kHz do 500 kHz od 1 V do 1,5 V CMC 0,16 %\n500 kHz do 1 MHz od 1 V do 1,5 V CMC 0,32 %\n10 Hz do 20 Hz od 1,5 V do 2,2 V CMC 0,056 %\n20 Hz do 40 Hz od 1,5 V do 2,2 V CMC 0,019 %\n40 Hz do 20 kHz od 1,5 V do 2,2 V CMC 0,0084 %\n20 kHz do 50 kHz od 1,5 V do 2,2 V CMC 0,014 %\n50 kHz do 100 kHz od 1,5 V do 2,2 V CMC 0,030 %\n100 kHz do 300 kHz od 1,5 V do 2,2 V CMC 0,053 %\n300 kHz do 500 kHz od 1,5 V do 2,2 V CMC 0,15 %\n500 kHz do 1 MHz od 1,5 V do 2,2 V CMC 0,29 %\n10 Hz do 20 Hz od 2,2 V do 3 V CMC 0,087 %\n20 Hz do 40 Hz od 2,2 V do 3 V CMC 0,028 %\n40 Hz do 20 kHz od 2,2 V do 3 V CMC 0,011 %\n20 kHz do 50 kHz od 2,2 V do 3 V CMC 0,020 %\n50 kHz do 100 kHz od 2,2 V do 3 V CMC 0,042 %\n100 kHz do 300 kHz od 2,2 V do 3 V CMC 0,12 %\n300 kHz do 500 kHz od 2,2 V do 3 V CMC 0,33 %\n500 kHz do 1 MHz od 2,2 V do 3 V CMC 0,67 %\n10 Hz do 20 Hz od 3 V do 5 V CMC 0,078 %\n20 Hz do 40 Hz od 3 V do 5 V CMC 0,025 %\n40 Hz do 20 kHz od 3 V do 5 V CMC 0,099 %\n20 kHz do 50 kHz od 3 V do 5 V CMC 0,018 %\n50 kHz do 100 kHz od 3 V do 5 V CMC 0,030 %\n100 kHz do 300 kHz od 3 V do 5 V CMC 0,11 %\n300 kHz do 500 kHz od 3 V do 5 V CMC 0,28 %\n500 kHz do 1 MHz od 3 V do 5 V CMC 0,56 %\n10 Hz do 20 Hz od 5 V do 10 V CMC 0,067 %\n20 Hz do 40 Hz od 5 V do 10 V CMC 0,022 %\n40 Hz do 20 kHz od 5 V do 10 V CMC 0,0091 %\n20 kHz do 50 kHz od 5 V do 10 V CMC 0,016 %\n50 kHz do 100 kHz od 5 V do 10 V CMC 0,033 %\n100 kHz do 300 kHz od 5 V do 10 V CMC 0,081 %\n300 kHz do 500 kHz od 5 V do 10 V CMC 0,23 %\n500 kHz do 1 MHz od 5 V do 10 V CMC 0,45 %\n10 Hz do 20 Hz od 10 V do 15 V CMC 0,059 %\n20 Hz do 40 Hz od 10 V do 15 V CMC 0,019 %\n40 Hz do 20 kHz od 10 V do 15 V CMC 0,0086 %\n20 kHz do 50 kHz od 10 V do 15 V CMC 0,014 %\n50 kHz do 100 kHz od 10 V do 15 V CMC 0,029 %\n100 kHz do 300 kHz od 10 V do 15 V CMC 0,066 %\n300 kHz do 500 kHz od 10 V do 15 V CMC 0,19 %\n500 kHz do 1 MHz od 10 V do 15 V CMC 0,37 %\n10 Hz do 20 Hz od 15 V do 22 V CMC 0,056 %\n20 Hz do 40 Hz od 15 V do 22 V CMC 0,019 %\n40 Hz do 20 kHz od 15 V do 22 V CMC 0,087 %\n20 kHz do 50 kHz od 15 V do 22 V CMC 0,014 %\n50 kHz do 100 kHz od 15 V do 22 V CMC 0,029 %\n100 kHz do 300 kHz od 15 V do 22 V CMC 0,061 %\n300 kHz do 500 kHz od 15 V do 22 V CMC 0,18 %\n500 kHz do 1 MHz od 15 V do 22 V CMC 0,34 %\n10 Hz do 20 Hz od 22 V do 30 V CMC 0,087 %\n20 Hz do 40 Hz od 22 V do 30 V CMC 0,028 %\n40 Hz do 20 kHz od 22 V do 30 V CMC 0,013 %\n20 kHz do 50 kHz od 22 V do 30 V CMC 0,039 %\n50 kHz do 100 kHz od 22 V do 30 V CMC 0,087 %\n10 Hz do 20 Hz od 30 V do 50 V CMC 0,078 %\n20 Hz do 40 Hz od 30 V do 50 V CMC 0,025 %\n40 Hz do 20 kHz od 30 V do 50 V CMC 0,012 %\n20 kHz do 50 kHz od 30 V do 50 V CMC 0,034 %\n50 kHz do 100 kHz od 30 V do 50 V CMC 0,078 %\n10 Hz do 20 Hz od 50 V do 100 V CMC 0,067 %\n20 Hz do 40 Hz od 50 V do 100 V CMC 0,022 %\n40 Hz do 20 kHz od 50 V do 100 V CMC 0,011 %\n20 kHz do 50 kHz od 50 V do 100 V CMC 0,030 %\n50 kHz do 100 kHz od 50 V do 100 V CMC 0,067 %\n10 Hz do 20 Hz od 100 V do 150 V CMC 0,059 %\n20 Hz do 40 Hz od 100 V do 150 V CMC 0,019 %\n40 Hz do 20 kHz od 100 V do 150 V CMC 0,010 %\n20 kHz do 50 kHz od 100 V do 150 V CMC 0,026 %\n50 kHz do 100 kHz od 100 V do 150 V CMC 0,059 %\n10 Hz do 20 Hz od 150 V do 220 V CMC 0,057 %\n20 Hz do 40 Hz od 150 V do 220 V CMC 0,019 %\n40 Hz do 20 kHz od 150 V do 220 V CMC 0,011 %\n20 kHz do 50 kHz od 150 V do 220 V CMC 0,027 %\n50 kHz do 100 kHz od 150 V do 220 V CMC 0,065 %\n10 Hz do 50 Hz od 220 V do 300 V CMC 0,030 %\n50 Hz do 1 kHz od 220 V do 300 V CMC 0,012 %\n1 kHz do 10 kHz od 220 V do 300 V CMC 0,026 %\n10 kHz do 30 kHz od 220 V do 300 V CMC 0,042 %\n10 Hz do 50 Hz od 300 V do 400 V CMC 0,030 %\n50 Hz do 1 kHz od 300 V do 400 V CMC 0,012 %\n1 kHz do 10 kHz od 300 V do 400 V CMC 0,026 %\n10 kHz do 30 kHz od 300 V do 400 V CMC 0,042 %\n10 Hz do 50 Hz od 400 V do 500 V CMC 0,028 %\n50 Hz do 1 kHz od 400 V do 500 V CMC 0,012 %\n1 kHz do 10 kHz od 400 V do 500 V CMC 0,025 %\n10 kHz do 30 kHz od 400 V do 500 V CMC 0,045 %\n10 Hz do 50 Hz od 500 V do 600 V CMC 0,027 %\n50 Hz do 1 kHz od 500 V do 600 V CMC 0,011 %\n1 kHz do 10 kHz od 500 V do 600 V CMC 0,023 %\n10 kHz do 30 kHz od 500 V do 600 V CMC 0,053 %\n10 Hz do 50 Hz od 600 V do 700 V CMC 0,028 %\n50 Hz do 1 kHz od 600 V do 700 V CMC 0,012 %\n1 kHz do 10 kHz od 600 V do 700 V CMC 0,025 %\n10 kHz do 30 kHz od 600 V do 700 V CMC 0,068 %\n10 Hz do 50 Hz od 700 V do 800 V CMC 0,030 %\n50 Hz do 1 kHz od 700 V do 800 V CMC 0,011 %\n1 kHz do 10 kHz od 700 V do 800 V CMC 0,028 %\n10 kHz do 30 kHz od 700 V do 800 V CMC 0,089 %\n10 Hz do 50 Hz od 800 V do 1050 V CMC 0,040 %\n50 Hz do 1 kHz od 800 V do 1050 V CMC 0,010 %\n1 kHz do 10 kHz od 800 V do 1050 V CMC 0,038 %\n10 kHz do 30 kHz od 800 V do 1050 V CMC 0,17 %\nBezpośrednie generowanie kalibratorem","reference":"TP2, TP21","norm_bases":["TP2","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / Mierniki napięcia stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 10 Hz do 50 kHz od 0,22 mV do 0,5 mV CMC 4,9 µV 50 kHz do 100 kHz od 0,22 mV do 0,5 mV CMC 7,6 µV 10 Hz do 20 Hz od 0,5 mV do 1 mV CMC 5,5 µV 20 Hz do 40 Hz od 0,5 mV do 1 mV CMC 5,2 µV 40 Hz do 20 kHz od 0,5 mV do 1 mV CMC 5,1 µV 20 kHz do 50 kHz od 0,5 mV do 1 mV CMC 5,3 µV 50 kHz do 100 kHz od 0,5 mV do 1 mV CMC 8,5 µV 10 Hz do 20 Hz od 1 mV do 2,2 mV CMC 5,9 µV 20 Hz do 20 kHz od 1 mV do 2,2 mV CMC 5,2 µV 20 kHz do 50 kHz od 1 mV do 2,2 mV CMC 5,6 µV 50 kHz do 100 kHz od 1 mV do 2,2 mV CMC 9,1 µV 100 kHz do 300 kHz od 1 mV do 2,2 mV CMC 16 µV 300 kHz do 500 kHz od 1 mV do 2,2 mV CMC 30 µV 500 kHz do 1 MHz od 1 mV do 2,2 mV CMC 34 µV 10 Hz do 20 Hz od 2,2 mV do 3 mV CMC 6,8 µV 20 Hz do 40 Hz od 2,2 mV do 3 mV CMC 5,8 µV 40 Hz do 20 kHz od 2,2 mV do 3 mV CMC 5,5 µV 20 kHz do 50 kHz od 2,2 mV do 3 mV CMC 6,3 µV 50 kHz do 100 kHz od 2,2 mV do 3 mV CMC 9,7 µV 100 kHz do 300 kHz od 2,2 mV do 3 mV CMC 16 µV 300 kHz do 500 kHz od 2,2 mV do 3 mV CMC 31 µV 500 kHz do 1 MHz od 2,2 mV do 3 mV CMC 36 µV 10 Hz do 20 Hz od 3 mV do 5 mV CMC 8,0 µV 20 Hz do 40 Hz od 3 mV do 5 mV CMC 6,4 µV 40 Hz do 20 kHz od 3 mV do 5 mV CMC 5,9 µV 20 kHz do 50 kHz od 3 mV do 5 mV CMC 7,1 µV 50 kHz do 100 kHz od 3 mV do 5 mV CMC 12 µV 100 kHz do 300 kHz od 3 mV do 5 mV CMC 18 µV 300 kHz do 500 kHz od 3 mV do 5 mV CMC 35 µV 500 kHz do 1 MHz od 3 mV do 5 mV CMC 43 µV 10 Hz do 20 Hz od 5 mV do 10 mV CMC 12 µV 20 Hz do 40 Hz od 5 mV do 10 mV CMC 8,0 µV 40 Hz do 20 kHz od 5 mV do 10 mV CMC 7,1 µV 20 kHz do 50 kHz od 5 mV do 10 mV CMC 9,4 µV 50 kHz do 100 kHz od 5 mV do 10 mV CMC 17 µV 100 kHz do 300 kHz od 5 mV do 10 mV CMC 25 µV 300 kHz do 500 kHz od 5 mV do 10 mV CMC 44 µV 500 kHz do 1 MHz od 5 mV do 10 mV CMC 61 µV 10 Hz do 20 Hz od 10 mV do 15 mV CMC 14 µV 20 Hz do 40 Hz od 10 mV do 15 mV CMC 8,8 µV 40 Hz do 20 kHz od 10 mV do 15 mV CMC 7,3 µV 20 kHz do 50 kHz od 10 mV do 15 mV CMC 12 µV 50 kHz do 100 kHz od 10 mV do 15 mV CMC 21 µV 100 kHz do 300 kHz od 10 mV do 15 mV CMC 31 µV 300 kHz do 500 kHz od 10 mV do 15 mV CMC 54 µV 500 kHz do 1 MHz od 10 mV do 15 mV CMC 78 µV 10 Hz do 20 Hz od 15 mV do 22 mV CMC 18 µV 20 Hz do 40 Hz od 15 mV do 22 mV CMC 10 µV 40 Hz do 20 kHz od 15 mV do 22 mV CMC 7,7 µV 20 kHz do 50 kHz od 15 mV do 22 mV CMC 14 µV 50 kHz do 100 kHz od 15 mV do 22 mV CMC 27 µV 100 kHz do 300 kHz od 15 mV do 22 mV CMC 39 µV 300 kHz do 500 kHz od 15 mV do 22 mV CMC 67 µV 500 kHz do 1 MHz od 15 mV do 22 mV CMC 0,11 mV 10 Hz do 20 Hz od 22 mV do 30 mV CMC 0,12 % 20 Hz do 40 Hz od 22 mV do 30 mV CMC 0,059 % 40 Hz do 20 kHz od 22 mV do 30 mV CMC 0,048 % 20 kHz do 50 kHz od 22 mV do 30 mV CMC 0,072 % 50 kHz do 100 kHz od 22 mV do 30 mV CMC 0,21 % 100 kHz do 300 kHz od 22 mV do 30 mV CMC 0,24 % 300 kHz do 500 kHz od 22 mV do 30 mV CMC 0,35 % 500 kHz do 1 MHz od 22 mV do 30 mV CMC 0,72 % 10 Hz do 20 Hz od 30 mV do 50 mV CMC 0,099 % 20 Hz do 40 Hz od 30 mV do 50 mV CMC 0,049 % 40 Hz do 20 kHz od 30 mV do 50 mV CMC 0,039 % 20 kHz do 50 kHz od 30 mV do 50 mV CMC 0,062 % 50 kHz do 100 kHz od 30 mV do 50 mV CMC 0,18 % 100 kHz do 300 kHz od 30 mV do 50 mV CMC 0,21 % 300 kHz do 500 kHz od 30 mV do 50 mV CMC 0,31 % 500 kHz do 1 MHz od 30 mV do 50 mV CMC 0,62 % 10 Hz do 20 Hz od 50 mV do 100 mV CMC 0,082 % 20 Hz do 40 Hz od 50 mV do 100 mV CMC 0,039 % 40 Hz do 20 kHz od 50 mV do 100 mV CMC 0,029 % 20 kHz do 50 kHz od 50 mV do 100 mV CMC 0,052 % 50 kHz do 100 kHz od 50 mV do 100 mV CMC 0,15 % 100 kHz do 300 kHz od 50 mV do 100 mV CMC 0,18 % 300 kHz do 500 kHz od 50 mV do 100 mV CMC 0,27 % 500 kHz do 1 MHz od 50 mV do 100 mV CMC 0,51 % 10 Hz do 20 Hz od 100 mV do 150 mV CMC 0,069 % 20 Hz do 40 Hz od 100 mV do 150 mV CMC 0,031 % 40 Hz do 20 kHz od 100 mV do 150 mV CMC 0,021 % 20 kHz do 50 kHz od 100 mV do 150 mV CMC 0,045 % 50 kHz do 100 kHz od 100 mV do 150 mV CMC 0,12 % 100 kHz do 300 kHz od 100 mV do 150 mV CMC 0,15 % 300 kHz do 500 kHz od 100 mV do 150 mV CMC 0,23 % 500 kHz do 1 MHz od 100 mV do 150 mV CMC 0,44 % 10 Hz do 20 Hz od 150 mV do 220 mV CMC 0,065 % 20 Hz do 40 Hz od 150 mV do 220 mV CMC 0,028 % 40 Hz do 20 kHz od 150 mV do 220 mV CMC 0,017 % 20 kHz do 50 kHz od 150 mV do 220 mV CMC 0,039 % 50 kHz do 100 kHz od 150 mV do 220 mV CMC 0,11 % 100 kHz do 300 kHz od 150 mV do 220 mV CMC 0,13 % 300 kHz do 500 kHz od 150 mV do 220 mV CMC 0,21 % 500 kHz do 1 MHz od 150 mV do 220 mV CMC 0,41 % 10 Hz do 20 Hz od 220 mV do 300 mV CMC 0,087 % 20 Hz do 40 Hz od 220 mV do 300 mV CMC 0,028 % 40 Hz do 20 kHz od 220 mV do 300 mV CMC 0,011 % 20 kHz do 50 kHz od 220 mV do 300 mV CMC 0,020 % 50 kHz do 100 kHz od 220 mV do 300 mV CMC 0,058 % 100 kHz do 300 kHz od 220 mV do 300 mV CMC 0,11 % 300 kHz do 500 kHz od 220 mV do 300 mV CMC 0,28 % 500 kHz do 1 MHz od 220 mV do 300 mV CMC 0,61 % 10 Hz do 20 Hz od 300 mV do 500 mV CMC 0,078 % 20 Hz do 40 Hz od 300 mV do 500 mV CMC 0,025 % 40 Hz do 20 kHz od 300 mV do 500 mV CMC 0,010 % 20 kHz do 50 kHz od 300 mV do 500 mV CMC 0,018 % 50 kHz do 100 kHz od 300 mV do 500 mV CMC 0,049 % 100 kHz do 300 kHz od 300 mV do 500 mV CMC 0,088 % 300 kHz do 500 kHz od 300 mV do 500 mV CMC 0,23 % 500 kHz do 1 MHz od 300 mV do 500 mV CMC 0,51 % 10 Hz do 20 Hz od 500 mV do 1 V CMC 0,067 % 20 Hz do 40 Hz od 500 mV do 1 V CMC 0,022 % 40 Hz do 20 kHz od 500 mV do 1 V CMC 0,0092 % 20 kHz do 50 kHz od 500 mV do 1 V CMC 0,016 % 50 kHz do 100 kHz od 500 mV do 1 V CMC 0,040 % 100 kHz do 300 kHz od 500 mV do 1 V CMC 0,071 % 300 kHz do 500 kHz od 500 mV do 1 V CMC 0,19 % 500 kHz do 1 MHz od 500 mV do 1 V CMC 0,40 % 10 Hz do 20 Hz od 1 V do 1,5 V CMC 0,059 % 20 Hz do 40 Hz od 1 V do 1,5 V CMC 0,019 % 40 Hz do 20 kHz od 1 V do 1,5 V CMC 0,0086 % 20 kHz do 50 kHz od 1 V do 1,5 V CMC 0,015 % 50 kHz do 100 kHz od 1 V do 1,5 V CMC 0,033 % 100 kHz do 300 kHz od 1 V do 1,5 V CMC 0,058 % 300 kHz do 500 kHz od 1 V do 1,5 V CMC 0,16 % 500 kHz do 1 MHz od 1 V do 1,5 V CMC 0,32 % 10 Hz do 20 Hz od 1,5 V do 2,2 V CMC 0,056 % 20 Hz do 40 Hz od 1,5 V do 2,2 V CMC 0,019 % 40 Hz do 20 kHz od 1,5 V do 2,2 V CMC 0,0084 % 20 kHz do 50 kHz od 1,5 V do 2,2 V CMC 0,014 % 50 kHz do 100 kHz od 1,5 V do 2,2 V CMC 0,030 % 100 kHz do 300 kHz od 1,5 V do 2,2 V CMC 0,053 % 300 kHz do 500 kHz od 1,5 V do 2,2 V CMC 0,15 % 500 kHz do 1 MHz od 1,5 V do 2,2 V CMC 0,29 % 10 Hz do 20 Hz od 2,2 V do 3 V CMC 0,087 % 20 Hz do 40 Hz od 2,2 V do 3 V CMC 0,028 % 40 Hz do 20 kHz od 2,2 V do 3 V CMC 0,011 % 20 kHz do 50 kHz od 2,2 V do 3 V CMC 0,020 % 50 kHz do 100 kHz od 2,2 V do 3 V CMC 0,042 % 100 kHz do 300 kHz od 2,2 V do 3 V CMC 0,12 % 300 kHz do 500 kHz od 2,2 V do 3 V CMC 0,33 % 500 kHz do 1 MHz od 2,2 V do 3 V CMC 0,67 % 10 Hz do 20 Hz od 3 V do 5 V CMC 0,078 % 20 Hz do 40 Hz od 3 V do 5 V CMC 0,025 % 40 Hz do 20 kHz od 3 V do 5 V CMC 0,099 % 20 kHz do 50 kHz od 3 V do 5 V CMC 0,018 % 50 kHz do 100 kHz od 3 V do 5 V CMC 0,030 % 100 kHz do 300 kHz od 3 V do 5 V CMC 0,11 % 300 kHz do 500 kHz od 3 V do 5 V CMC 0,28 % 500 kHz do 1 MHz od 3 V do 5 V CMC 0,56 % 10 Hz do 20 Hz od 5 V do 10 V CMC 0,067 % 20 Hz do 40 Hz od 5 V do 10 V CMC 0,022 % 40 Hz do 20 kHz od 5 V do 10 V CMC 0,0091 % 20 kHz do 50 kHz od 5 V do 10 V CMC 0,016 % 50 kHz do 100 kHz od 5 V do 10 V CMC 0,033 % 100 kHz do 300 kHz od 5 V do 10 V CMC 0,081 % 300 kHz do 500 kHz od 5 V do 10 V CMC 0,23 % 500 kHz do 1 MHz od 5 V do 10 V CMC 0,45 % 10 Hz do 20 Hz od 10 V do 15 V CMC 0,059 % 20 Hz do 40 Hz od 10 V do 15 V CMC 0,019 % 40 Hz do 20 kHz od 10 V do 15 V CMC 0,0086 % 20 kHz do 50 kHz od 10 V do 15 V CMC 0,014 % 50 kHz do 100 kHz od 10 V do 15 V CMC 0,029 % 100 kHz do 300 kHz od 10 V do 15 V CMC 0,066 % 300 kHz do 500 kHz od 10 V do 15 V CMC 0,19 % 500 kHz do 1 MHz od 10 V do 15 V CMC 0,37 % 10 Hz do 20 Hz od 15 V do 22 V CMC 0,056 % 20 Hz do 40 Hz od 15 V do 22 V CMC 0,019 % 40 Hz do 20 kHz od 15 V do 22 V CMC 0,087 % 20 kHz do 50 kHz od 15 V do 22 V CMC 0,014 % 50 kHz do 100 kHz od 15 V do 22 V CMC 0,029 % 100 kHz do 300 kHz od 15 V do 22 V CMC 0,061 % 300 kHz do 500 kHz od 15 V do 22 V CMC 0,18 % 500 kHz do 1 MHz od 15 V do 22 V CMC 0,34 % 10 Hz do 20 Hz od 22 V do 30 V CMC 0,087 % 20 Hz do 40 Hz od 22 V do 30 V CMC 0,028 % 40 Hz do 20 kHz od 22 V do 30 V CMC 0,013 % 20 kHz do 50 kHz od 22 V do 30 V CMC 0,039 % 50 kHz do 100 kHz od 22 V do 30 V CMC 0,087 % 10 Hz do 20 Hz od 30 V do 50 V CMC 0,078 % 20 Hz do 40 Hz od 30 V do 50 V CMC 0,025 % 40 Hz do 20 kHz od 30 V do 50 V CMC 0,012 % 20 kHz do 50 kHz od 30 V do 50 V CMC 0,034 % 50 kHz do 100 kHz od 30 V do 50 V CMC 0,078 % 10 Hz do 20 Hz od 50 V do 100 V CMC 0,067 % 20 Hz do 40 Hz od 50 V do 100 V CMC 0,022 % 40 Hz do 20 kHz od 50 V do 100 V CMC 0,011 % 20 kHz do 50 kHz od 50 V do 100 V CMC 0,030 % 50 kHz do 100 kHz od 50 V do 100 V CMC 0,067 % 10 Hz do 20 Hz od 100 V do 150 V CMC 0,059 % 20 Hz do 40 Hz od 100 V do 150 V CMC 0,019 % 40 Hz do 20 kHz od 100 V do 150 V CMC 0,010 % 20 kHz do 50 kHz od 100 V do 150 V CMC 0,026 % 50 kHz do 100 kHz od 100 V do 150 V CMC 0,059 % 10 Hz do 20 Hz od 150 V do 220 V CMC 0,057 % 20 Hz do 40 Hz od 150 V do 220 V CMC 0,019 % 40 Hz do 20 kHz od 150 V do 220 V CMC 0,011 % 20 kHz do 50 kHz od 150 V do 220 V CMC 0,027 % 50 kHz do 100 kHz od 150 V do 220 V CMC 0,065 % 10 Hz do 50 Hz od 220 V do 300 V CMC 0,030 % 50 Hz do 1 kHz od 220 V do 300 V CMC 0,012 % 1 kHz do 10 kHz od 220 V do 300 V CMC 0,026 % 10 kHz do 30 kHz od 220 V do 300 V CMC 0,042 % 10 Hz do 50 Hz od 300 V do 400 V CMC 0,030 % 50 Hz do 1 kHz od 300 V do 400 V CMC 0,012 % 1 kHz do 10 kHz od 300 V do 400 V CMC 0,026 % 10 kHz do 30 kHz od 300 V do 400 V CMC 0,042 % 10 Hz do 50 Hz od 400 V do 500 V CMC 0,028 % 50 Hz do 1 kHz od 400 V do 500 V CMC 0,012 % 1 kHz do 10 kHz od 400 V do 500 V CMC 0,025 % 10 kHz do 30 kHz od 400 V do 500 V CMC 0,045 % 10 Hz do 50 Hz od 500 V do 600 V CMC 0,027 % 50 Hz do 1 kHz od 500 V do 600 V CMC 0,011 % 1 kHz do 10 kHz od 500 V do 600 V CMC 0,023 % 10 kHz do 30 kHz od 500 V do 600 V CMC 0,053 % 10 Hz do 50 Hz od 600 V do 700 V CMC 0,028 % 50 Hz do 1 kHz od 600 V do 700 V CMC 0,012 % 1 kHz do 10 kHz od 600 V do 700 V CMC 0,025 % 10 kHz do 30 kHz od 600 V do 700 V CMC 0,068 % 10 Hz do 50 Hz od 700 V do 800 V CMC 0,030 % 50 Hz do 1 kHz od 700 V do 800 V CMC 0,011 % 1 kHz do 10 kHz od 700 V do 800 V CMC 0,028 % 10 kHz do 30 kHz od 700 V do 800 V CMC 0,089 % 10 Hz do 50 Hz od 800 V do 1050 V CMC 0,040 % 50 Hz do 1 kHz od 800 V do 1050 V CMC 0,010 % 1 kHz do 10 kHz od 800 V do 1050 V CMC 0,038 % 10 kHz do 30 kHz od 800 V do 1050 V CMC 0,17 % Střídavé napětí / Měřidla stejnosměrného napětí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 10 Hz až 50 kHz 0,22 mV až 0,5 mV CMC 4,9 µV 50 kHz až 100 kHz 0,22 mV až 0,5 mV CMC 7,6 µV 10 Hz až 20 Hz 0,5 mV až 1 mV CMC 5,5 µV 20 Hz až 40 Hz 0,5 mV až 1 mV CMC 5,2 µV 40 Hz až 20 kHz 0,5 mV až 1 mV CMC 5,1 µV 20 kHz až 50 kHz 0,5 mV až 1 mV CMC 5,3 µV 50 kHz až 100 kHz 0,5 mV až 1 mV CMC 8,5 µV 10 Hz až 20 Hz 1 mV až 2,2 mV CMC 5,9 µV 20 Hz až 20 kHz 1 mV až 2,2 mV CMC 5,2 µV 20 kHz až 50 kHz 1 mV až 2,2 mV CMC 5,6 µV 50 kHz až 100 kHz 1 mV až 2,2 mV CMC 9,1 µV 100 kHz až 300 kHz 1 mV až 2,2 mV CMC 16 µV 300 kHz až 500 kHz 1 mV až 2,2 mV CMC 30 µV 500 kHz až 1 MHz 1 mV až 2,2 mV CMC 34 µV 10 Hz až 20 Hz 2,2 mV až 3 mV CMC 6,8 µV 20 Hz až 40 Hz 2,2 mV až 3 mV CMC 5,8 µV 40 Hz až 20 kHz 2,2 mV až 3 mV CMC 5,5 µV 20 kHz až 50 kHz 2,2 mV až 3 mV CMC 6,3 µV 50 kHz až 100 kHz 2,2 mV až 3 mV CMC 9,7 µV 100 kHz až 300 kHz 2,2 mV až 3 mV CMC 16 µV 300 kHz až 500 kHz 2,2 mV až 3 mV CMC 31 µV 500 kHz až 1 MHz 2,2 mV až 3 mV CMC 36 µV 10 Hz až 20 Hz 3 mV až 5 mV CMC 8,0 µV 20 Hz až 40 Hz 3 mV až 5 mV CMC 6,4 µV 40 Hz až 20 kHz 3 mV až 5 mV CMC 5,9 µV 20 kHz až 50 kHz 3 mV až 5 mV CMC 7,1 µV 50 kHz až 100 kHz 3 mV až 5 mV CMC 12 µV 100 kHz až 300 kHz 3 mV až 5 mV CMC 18 µV 300 kHz až 500 kHz 3 mV až 5 mV CMC 35 µV 500 kHz až 1 MHz 3 mV až 5 mV CMC 43 µV 10 Hz až 20 Hz 5 mV až 10 mV CMC 12 µV 20 Hz až 40 Hz 5 mV až 10 mV CMC 8,0 µV 40 Hz až 20 kHz 5 mV až 10 mV CMC 7,1 µV 20 kHz až 50 kHz 5 mV až 10 mV CMC 9,4 µV 50 kHz až 100 kHz 5 mV až 10 mV CMC 17 µV 100 kHz až 300 kHz 5 mV až 10 mV CMC 25 µV 300 kHz až 500 kHz 5 mV až 10 mV CMC 44 µV 500 kHz až 1 MHz 5 mV až 10 mV CMC 61 µV 10 Hz až 20 Hz 10 mV až 15 mV CMC 14 µV 20 Hz až 40 Hz 10 mV až 15 mV CMC 8,8 µV 40 Hz až 20 kHz 10 mV až 15 mV CMC 7,3 µV 20 kHz až 50 kHz 10 mV až 15 mV CMC 12 µV 50 kHz až 100 kHz 10 mV až 15 mV CMC 21 µV 100 kHz až 300 kHz 10 mV až 15 mV CMC 31 µV 300 kHz až 500 kHz 10 mV až 15 mV CMC 54 µV 500 kHz až 1 MHz 10 mV až 15 mV CMC 78 µV 10 Hz až 20 Hz 15 mV až 22 mV CMC 18 µV 20 Hz až 40 Hz 15 mV až 22 mV CMC 10 µV 40 Hz až 20 kHz 15 mV až 22 mV CMC 7,7 µV 20 kHz až 50 kHz 15 mV až 22 mV CMC 14 µV 50 kHz až 100 kHz 15 mV až 22 mV CMC 27 µV 100 kHz až 300 kHz 15 mV až 22 mV CMC 39 µV 300 kHz až 500 kHz 15 mV až 22 mV CMC 67 µV 500 kHz až 1 MHz 15 mV až 22 mV CMC 0,11 mV 10 Hz až 20 Hz 22 mV až 30 mV CMC 0,12 % 20 Hz až 40 Hz 22 mV až 30 mV CMC 0,059 % 40 Hz až 20 kHz 22 mV až 30 mV CMC 0,048 % 20 kHz až 50 kHz 22 mV až 30 mV CMC 0,072 % 50 kHz až 100 kHz 22 mV až 30 mV CMC 0,21 % 100 kHz až 300 kHz 22 mV až 30 mV CMC 0,24 % 300 kHz až 500 kHz 22 mV až 30 mV CMC 0,35 % 500 kHz až 1 MHz 22 mV až 30 mV CMC 0,72 % 10 Hz až 20 Hz 30 mV až 50 mV CMC 0,099 % 20 Hz až 40 Hz 30 mV až 50 mV CMC 0,049 % 40 Hz až 20 kHz 30 mV až 50 mV CMC 0,039 % 20 kHz až 50 kHz 30 mV až 50 mV CMC 0,062 % 50 kHz až 100 kHz 30 mV až 50 mV CMC 0,18 % 100 kHz až 300 kHz 30 mV až 50 mV CMC 0,21 % 300 kHz až 500 kHz 30 mV až 50 mV CMC 0,31 % 500 kHz až 1 MHz 30 mV až 50 mV CMC 0,62 % 10 Hz až 20 Hz 50 mV až 100 mV CMC 0,082 % 20 Hz až 40 Hz 50 mV až 100 mV CMC 0,039 % 40 Hz až 20 kHz 50 mV až 100 mV CMC 0,029 % 20 kHz až 50 kHz 50 mV až 100 mV CMC 0,052 % 50 kHz až 100 kHz 50 mV až 100 mV CMC 0,15 % 100 kHz až 300 kHz 50 mV až 100 mV CMC 0,18 % 300 kHz až 500 kHz 50 mV až 100 mV CMC 0,27 % 500 kHz až 1 MHz 50 mV až 100 mV CMC 0,51 % 10 Hz až 20 Hz 100 mV až 150 mV CMC 0,069 % 20 Hz až 40 Hz 100 mV až 150 mV CMC 0,031 % 40 Hz až 20 kHz 100 mV až 150 mV CMC 0,021 % 20 kHz až 50 kHz 100 mV až 150 mV CMC 0,045 % 50 kHz až 100 kHz 100 mV až 150 mV CMC 0,12 % 100 kHz až 300 kHz 100 mV až 150 mV CMC 0,15 % 300 kHz až 500 kHz 100 mV až 150 mV CMC 0,23 % 500 kHz až 1 MHz 100 mV až 150 mV CMC 0,44 % 10 Hz až 20 Hz 150 mV až 220 mV CMC 0,065 % 20 Hz až 40 Hz 150 mV až 220 mV CMC 0,028 % 40 Hz až 20 kHz 150 mV až 220 mV CMC 0,017 % 20 kHz až 50 kHz 150 mV až 220 mV CMC 0,039 % 50 kHz až 100 kHz 150 mV až 220 mV CMC 0,11 % 100 kHz až 300 kHz 150 mV až 220 mV CMC 0,13 % 300 kHz až 500 kHz 150 mV až 220 mV CMC 0,21 % 500 kHz až 1 MHz 150 mV až 220 mV CMC 0,41 % 10 Hz až 20 Hz 220 mV až 300 mV CMC 0,087 % 20 Hz až 40 Hz 220 mV až 300 mV CMC 0,028 % 40 Hz až 20 kHz 220 mV až 300 mV CMC 0,011 % 20 kHz až 50 kHz 220 mV až 300 mV CMC 0,020 % 50 kHz až 100 kHz 220 mV až 300 mV CMC 0,058 % 100 kHz až 300 kHz 220 mV až 300 mV CMC 0,11 % 300 kHz až 500 kHz 220 mV až 300 mV CMC 0,28 % 500 kHz až 1 MHz 220 mV až 300 mV CMC 0,61 % 10 Hz až 20 Hz 300 mV až 500 mV CMC 0,078 % 20 Hz až 40 Hz 300 mV až 500 mV CMC 0,025 % 40 Hz až 20 kHz 300 mV až 500 mV CMC 0,010 % 20 kHz až 50 kHz 300 mV až 500 mV CMC 0,018 % 50 kHz až 100 kHz 300 mV až 500 mV CMC 0,049 % 100 kHz až 300 kHz 300 mV až 500 mV CMC 0,088 % 300 kHz až 500 kHz 300 mV až 500 mV CMC 0,23 % 500 kHz až 1 MHz 300 mV až 500 mV CMC 0,51 % 10 Hz až 20 Hz 500 mV až 1 V CMC 0,067 % 20 Hz až 40 Hz 500 mV až 1 V CMC 0,022 % 40 Hz až 20 kHz 500 mV až 1 V CMC 0,0092 % 20 kHz až 50 kHz 500 mV až 1 V CMC 0,016 % 50 kHz až 100 kHz 500 mV až 1 V CMC 0,040 % 100 kHz až 300 kHz 500 mV až 1 V CMC 0,071 % 300 kHz až 500 kHz 500 mV až 1 V CMC 0,19 % 500 kHz až 1 MHz 500 mV až 1 V CMC 0,40 % 10 Hz až 20 Hz 1 V až 1,5 V CMC 0,059 % 20 Hz až 40 Hz 1 V až 1,5 V CMC 0,019 % 40 Hz až 20 kHz 1 V až 1,5 V CMC 0,0086 % 20 kHz až 50 kHz 1 V až 1,5 V CMC 0,015 % 50 kHz až 100 kHz 1 V až 1,5 V CMC 0,033 % 100 kHz až 300 kHz 1 V až 1,5 V CMC 0,058 % 300 kHz až 500 kHz 1 V až 1,5 V CMC 0,16 % 500 kHz až 1 MHz 1 V až 1,5 V CMC 0,32 % 10 Hz až 20 Hz 1,5 V až 2,2 V CMC 0,056 % 20 Hz až 40 Hz 1,5 V až 2,2 V CMC 0,019 % 40 Hz až 20 kHz 1,5 V až 2,2 V CMC 0,0084 % 20 kHz až 50 kHz 1,5 V až 2,2 V CMC 0,014 % 50 kHz až 100 kHz 1,5 V až 2,2 V CMC 0,030 % 100 kHz až 300 kHz 1,5 V až 2,2 V CMC 0,053 % 300 kHz až 500 kHz 1,5 V až 2,2 V CMC 0,15 % 500 kHz až 1 MHz 1,5 V až 2,2 V CMC 0,29 % 10 Hz až 20 Hz 2,2 V až 3 V CMC 0,087 % 20 Hz až 40 Hz 2,2 V až 3 V CMC 0,028 % 40 Hz až 20 kHz 2,2 V až 3 V CMC 0,011 % 20 kHz až 50 kHz 2,2 V až 3 V CMC 0,020 % 50 kHz až 100 kHz 2,2 V až 3 V CMC 0,042 % 100 kHz až 300 kHz 2,2 V až 3 V CMC 0,12 % 300 kHz až 500 kHz 2,2 V až 3 V CMC 0,33 % 500 kHz až 1 MHz 2,2 V až 3 V CMC 0,67 % 10 Hz až 20 Hz 3 V až 5 V CMC 0,078 % 20 Hz až 40 Hz 3 V až 5 V CMC 0,025 % 40 Hz až 20 kHz 3 V až 5 V CMC 0,099 % 20 kHz až 50 kHz 3 V až 5 V CMC 0,018 % 50 kHz až 100 kHz 3 V až 5 V CMC 0,030 % 100 kHz až 300 kHz 3 V až 5 V CMC 0,11 % 300 kHz až 500 kHz 3 V až 5 V CMC 0,28 % 500 kHz až 1 MHz 3 V až 5 V CMC 0,56 % 10 Hz až 20 Hz 5 V až 10 V CMC 0,067 % 20 Hz až 40 Hz 5 V až 10 V CMC 0,022 % 40 Hz až 20 kHz 5 V až 10 V CMC 0,0091 % 20 kHz až 50 kHz 5 V až 10 V CMC 0,016 % 50 kHz až 100 kHz 5 V až 10 V CMC 0,033 % 100 kHz až 300 kHz 5 V až 10 V CMC 0,081 % 300 kHz až 500 kHz 5 V až 10 V CMC 0,23 % 500 kHz až 1 MHz 5 V až 10 V CMC 0,45 % 10 Hz až 20 Hz 10 V až 15 V CMC 0,059 % 20 Hz až 40 Hz 10 V až 15 V CMC 0,019 % 40 Hz až 20 kHz 10 V až 15 V CMC 0,0086 % 20 kHz až 50 kHz 10 V až 15 V CMC 0,014 % 50 kHz až 100 kHz 10 V až 15 V CMC 0,029 % 100 kHz až 300 kHz 10 V až 15 V CMC 0,066 % 300 kHz až 500 kHz 10 V až 15 V CMC 0,19 % 500 kHz až 1 MHz 10 V až 15 V CMC 0,37 % 10 Hz až 20 Hz 15 V až 22 V CMC 0,056 % 20 Hz až 40 Hz 15 V až 22 V CMC 0,019 % 40 Hz až 20 kHz 15 V až 22 V CMC 0,087 % 20 kHz až 50 kHz 15 V až 22 V CMC 0,014 % 50 kHz až 100 kHz 15 V až 22 V CMC 0,029 % 100 kHz až 300 kHz 15 V až 22 V CMC 0,061 % 300 kHz až 500 kHz 15 V až 22 V CMC 0,18 % 500 kHz až 1 MHz 15 V až 22 V CMC 0,34 % 10 Hz až 20 Hz 22 V až 30 V CMC 0,087 % 20 Hz až 40 Hz 22 V až 30 V CMC 0,028 % 40 Hz až 20 kHz 22 V až 30 V CMC 0,013 % 20 kHz až 50 kHz 22 V až 30 V CMC 0,039 % 50 kHz až 100 kHz 22 V až 30 V CMC 0,087 % 10 Hz až 20 Hz 30 V až 50 V CMC 0,078 % 20 Hz až 40 Hz 30 V až 50 V CMC 0,025 % 40 Hz až 20 kHz 30 V až 50 V CMC 0,012 % 20 kHz až 50 kHz 30 V až 50 V CMC 0,034 % 50 kHz až 100 kHz 30 V až 50 V CMC 0,078 % 10 Hz až 20 Hz 50 V až 100 V CMC 0,067 % 20 Hz až 40 Hz 50 V až 100 V CMC 0,022 % 40 Hz až 20 kHz 50 V až 100 V CMC 0,011 % 20 kHz až 50 kHz 50 V až 100 V CMC 0,030 % 50 kHz až 100 kHz 50 V až 100 V CMC 0,067 % 10 Hz až 20 Hz 100 V až 150 V CMC 0,059 % 20 Hz až 40 Hz 100 V až 150 V CMC 0,019 % 40 Hz až 20 kHz 100 V až 150 V CMC 0,010 % 20 kHz až 50 kHz 100 V až 150 V CMC 0,026 % 50 kHz až 100 kHz 100 V až 150 V CMC 0,059 % 10 Hz až 20 Hz 150 V až 220 V CMC 0,057 % 20 Hz až 40 Hz 150 V až 220 V CMC 0,019 % 40 Hz až 20 kHz 150 V až 220 V CMC 0,011 % 20 kHz až 50 kHz 150 V až 220 V CMC 0,027 % 50 kHz až 100 kHz 150 V až 220 V CMC 0,065 % 10 Hz až 50 Hz 220 V až 300 V CMC 0,030 % 50 Hz až 1 kHz 220 V až 300 V CMC 0,012 % 1 kHz až 10 kHz 220 V až 300 V CMC 0,026 % 10 kHz až 30 kHz 220 V až 300 V CMC 0,042 % 10 Hz až 50 Hz 300 V až 400 V CMC 0,030 % 50 Hz až 1 kHz 300 V až 400 V CMC 0,012 % 1 kHz až 10 kHz 300 V až 400 V CMC 0,026 % 10 kHz až 30 kHz 300 V až 400 V CMC 0,042 % 10 Hz až 50 Hz 400 V až 500 V CMC 0,028 % 50 Hz až 1 kHz 400 V až 500 V CMC 0,012 % 1 kHz až 10 kHz 400 V až 500 V CMC 0,025 % 10 kHz až 30 kHz 400 V až 500 V CMC 0,045 % 10 Hz až 50 Hz 500 V až 600 V CMC 0,027 % 50 Hz až 1 kHz 500 V až 600 V CMC 0,011 % 1 kHz až 10 kHz 500 V až 600 V CMC 0,023 % 10 kHz až 30 kHz 500 V až 600 V CMC 0,053 % 10 Hz až 50 Hz 600 V až 700 V CMC 0,028 % 50 Hz až 1 kHz 600 V až 700 V CMC 0,012 % 1 kHz až 10 kHz 600 V až 700 V CMC 0,025 % 10 kHz až 30 kHz 600 V až 700 V CMC 0,068 % 10 Hz až 50 Hz 700 V až 800 V CMC 0,030 % 50 Hz až 1 kHz 700 V až 800 V CMC 0,011 % 1 kHz až 10 kHz 700 V až 800 V CMC 0,028 % 10 kHz až 30 kHz 700 V až 800 V CMC 0,089 % 10 Hz až 50 Hz 800 V až 1050 V CMC 0,040 % 50 Hz až 1 kHz 800 V až 1050 V CMC 0,010 % 1 kHz až 10 kHz 800 V až 1050 V CMC 0,038 % 10 kHz až 30 kHz 800 V až 1050 V CMC 0,17 % TP2, TP21 Napiecie przemienne / Mierniki napiecia stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 10 Hz do 50 kHz od 0,22 mV do 0,5 mV CMC 4,9 µV 50 kHz do 100 kHz od 0,22 mV do 0,5 mV CMC 7,6 µV 10 Hz do 20 Hz od 0,5 mV do 1 mV CMC 5,5 µV 20 Hz do 40 Hz od 0,5 mV do 1 mV CMC 5,2 µV 40 Hz do 20 kHz od 0,5 mV do 1 mV CMC 5,1 µV 20 kHz do 50 kHz od 0,5 mV do 1 mV CMC 5,3 µV 50 kHz do 100 kHz od 0,5 mV do 1 mV CMC 8,5 µV 10 Hz do 20 Hz od 1 mV do 2,2 mV CMC 5,9 µV 20 Hz do 20 kHz od 1 mV do 2,2 mV CMC 5,2 µV 20 kHz do 50 kHz od 1 mV do 2,2 mV CMC 5,6 µV 50 kHz do 100 kHz od 1 mV do 2,2 mV CMC 9,1 µV 100 kHz do 300 kHz od 1 mV do 2,2 mV CMC 16 µV 300 kHz do 500 kHz od 1 mV do 2,2 mV CMC 30 µV 500 kHz do 1 MHz od 1 mV do 2,2 mV CMC 34 µV 10 Hz do 20 Hz od 2,2 mV do 3 mV CMC 6,8 µV 20 Hz do 40 Hz od 2,2 mV do 3 mV CMC 5,8 µV 40 Hz do 20 kHz od 2,2 mV do 3 mV CMC 5,5 µV 20 kHz do 50 kHz od 2,2 mV do 3 mV CMC 6,3 µV 50 kHz do 100 kHz od 2,2 mV do 3 mV CMC 9,7 µV 100 kHz do 300 kHz od 2,2 mV do 3 mV CMC 16 µV 300 kHz do 500 kHz od 2,2 mV do 3 mV CMC 31 µV 500 kHz do 1 MHz od 2,2 mV do 3 mV CMC 36 µV 10 Hz do 20 Hz od 3 mV do 5 mV CMC 8,0 µV 20 Hz do 40 Hz od 3 mV do 5 mV CMC 6,4 µV 40 Hz do 20 kHz od 3 mV do 5 mV CMC 5,9 µV 20 kHz do 50 kHz od 3 mV do 5 mV CMC 7,1 µV 50 kHz do 100 kHz od 3 mV do 5 mV CMC 12 µV 100 kHz do 300 kHz od 3 mV do 5 mV CMC 18 µV 300 kHz do 500 kHz od 3 mV do 5 mV CMC 35 µV 500 kHz do 1 MHz od 3 mV do 5 mV CMC 43 µV 10 Hz do 20 Hz od 5 mV do 10 mV CMC 12 µV 20 Hz do 40 Hz od 5 mV do 10 mV CMC 8,0 µV 40 Hz do 20 kHz od 5 mV do 10 mV CMC 7,1 µV 20 kHz do 50 kHz od 5 mV do 10 mV CMC 9,4 µV 50 kHz do 100 kHz od 5 mV do 10 mV CMC 17 µV 100 kHz do 300 kHz od 5 mV do 10 mV CMC 25 µV 300 kHz do 500 kHz od 5 mV do 10 mV CMC 44 µV 500 kHz do 1 MHz od 5 mV do 10 mV CMC 61 µV 10 Hz do 20 Hz od 10 mV do 15 mV CMC 14 µV 20 Hz do 40 Hz od 10 mV do 15 mV CMC 8,8 µV 40 Hz do 20 kHz od 10 mV do 15 mV CMC 7,3 µV 20 kHz do 50 kHz od 10 mV do 15 mV CMC 12 µV 50 kHz do 100 kHz od 10 mV do 15 mV CMC 21 µV 100 kHz do 300 kHz od 10 mV do 15 mV CMC 31 µV 300 kHz do 500 kHz od 10 mV do 15 mV CMC 54 µV 500 kHz do 1 MHz od 10 mV do 15 mV CMC 78 µV 10 Hz do 20 Hz od 15 mV do 22 mV CMC 18 µV 20 Hz do 40 Hz od 15 mV do 22 mV CMC 10 µV 40 Hz do 20 kHz od 15 mV do 22 mV CMC 7,7 µV 20 kHz do 50 kHz od 15 mV do 22 mV CMC 14 µV 50 kHz do 100 kHz od 15 mV do 22 mV CMC 27 µV 100 kHz do 300 kHz od 15 mV do 22 mV CMC 39 µV 300 kHz do 500 kHz od 15 mV do 22 mV CMC 67 µV 500 kHz do 1 MHz od 15 mV do 22 mV CMC 0,11 mV 10 Hz do 20 Hz od 22 mV do 30 mV CMC 0,12 % 20 Hz do 40 Hz od 22 mV do 30 mV CMC 0,059 % 40 Hz do 20 kHz od 22 mV do 30 mV CMC 0,048 % 20 kHz do 50 kHz od 22 mV do 30 mV CMC 0,072 % 50 kHz do 100 kHz od 22 mV do 30 mV CMC 0,21 % 100 kHz do 300 kHz od 22 mV do 30 mV CMC 0,24 % 300 kHz do 500 kHz od 22 mV do 30 mV CMC 0,35 % 500 kHz do 1 MHz od 22 mV do 30 mV CMC 0,72 % 10 Hz do 20 Hz od 30 mV do 50 mV CMC 0,099 % 20 Hz do 40 Hz od 30 mV do 50 mV CMC 0,049 % 40 Hz do 20 kHz od 30 mV do 50 mV CMC 0,039 % 20 kHz do 50 kHz od 30 mV do 50 mV CMC 0,062 % 50 kHz do 100 kHz od 30 mV do 50 mV CMC 0,18 % 100 kHz do 300 kHz od 30 mV do 50 mV CMC 0,21 % 300 kHz do 500 kHz od 30 mV do 50 mV CMC 0,31 % 500 kHz do 1 MHz od 30 mV do 50 mV CMC 0,62 % 10 Hz do 20 Hz od 50 mV do 100 mV CMC 0,082 % 20 Hz do 40 Hz od 50 mV do 100 mV CMC 0,039 % 40 Hz do 20 kHz od 50 mV do 100 mV CMC 0,029 % 20 kHz do 50 kHz od 50 mV do 100 mV CMC 0,052 % 50 kHz do 100 kHz od 50 mV do 100 mV CMC 0,15 % 100 kHz do 300 kHz od 50 mV do 100 mV CMC 0,18 % 300 kHz do 500 kHz od 50 mV do 100 mV CMC 0,27 % 500 kHz do 1 MHz od 50 mV do 100 mV CMC 0,51 % 10 Hz do 20 Hz od 100 mV do 150 mV CMC 0,069 % 20 Hz do 40 Hz od 100 mV do 150 mV CMC 0,031 % 40 Hz do 20 kHz od 100 mV do 150 mV CMC 0,021 % 20 kHz do 50 kHz od 100 mV do 150 mV CMC 0,045 % 50 kHz do 100 kHz od 100 mV do 150 mV CMC 0,12 % 100 kHz do 300 kHz od 100 mV do 150 mV CMC 0,15 % 300 kHz do 500 kHz od 100 mV do 150 mV CMC 0,23 % 500 kHz do 1 MHz od 100 mV do 150 mV CMC 0,44 % 10 Hz do 20 Hz od 150 mV do 220 mV CMC 0,065 % 20 Hz do 40 Hz od 150 mV do 220 mV CMC 0,028 % 40 Hz do 20 kHz od 150 mV do 220 mV CMC 0,017 % 20 kHz do 50 kHz od 150 mV do 220 mV CMC 0,039 % 50 kHz do 100 kHz od 150 mV do 220 mV CMC 0,11 % 100 kHz do 300 kHz od 150 mV do 220 mV CMC 0,13 % 300 kHz do 500 kHz od 150 mV do 220 mV CMC 0,21 % 500 kHz do 1 MHz od 150 mV do 220 mV CMC 0,41 % 10 Hz do 20 Hz od 220 mV do 300 mV CMC 0,087 % 20 Hz do 40 Hz od 220 mV do 300 mV CMC 0,028 % 40 Hz do 20 kHz od 220 mV do 300 mV CMC 0,011 % 20 kHz do 50 kHz od 220 mV do 300 mV CMC 0,020 % 50 kHz do 100 kHz od 220 mV do 300 mV CMC 0,058 % 100 kHz do 300 kHz od 220 mV do 300 mV CMC 0,11 % 300 kHz do 500 kHz od 220 mV do 300 mV CMC 0,28 % 500 kHz do 1 MHz od 220 mV do 300 mV CMC 0,61 % 10 Hz do 20 Hz od 300 mV do 500 mV CMC 0,078 % 20 Hz do 40 Hz od 300 mV do 500 mV CMC 0,025 % 40 Hz do 20 kHz od 300 mV do 500 mV CMC 0,010 % 20 kHz do 50 kHz od 300 mV do 500 mV CMC 0,018 % 50 kHz do 100 kHz od 300 mV do 500 mV CMC 0,049 % 100 kHz do 300 kHz od 300 mV do 500 mV CMC 0,088 % 300 kHz do 500 kHz od 300 mV do 500 mV CMC 0,23 % 500 kHz do 1 MHz od 300 mV do 500 mV CMC 0,51 % 10 Hz do 20 Hz od 500 mV do 1 V CMC 0,067 % 20 Hz do 40 Hz od 500 mV do 1 V CMC 0,022 % 40 Hz do 20 kHz od 500 mV do 1 V CMC 0,0092 % 20 kHz do 50 kHz od 500 mV do 1 V CMC 0,016 % 50 kHz do 100 kHz od 500 mV do 1 V CMC 0,040 % 100 kHz do 300 kHz od 500 mV do 1 V CMC 0,071 % 300 kHz do 500 kHz od 500 mV do 1 V CMC 0,19 % 500 kHz do 1 MHz od 500 mV do 1 V CMC 0,40 % 10 Hz do 20 Hz od 1 V do 1,5 V CMC 0,059 % 20 Hz do 40 Hz od 1 V do 1,5 V CMC 0,019 % 40 Hz do 20 kHz od 1 V do 1,5 V CMC 0,0086 % 20 kHz do 50 kHz od 1 V do 1,5 V CMC 0,015 % 50 kHz do 100 kHz od 1 V do 1,5 V CMC 0,033 % 100 kHz do 300 kHz od 1 V do 1,5 V CMC 0,058 % 300 kHz do 500 kHz od 1 V do 1,5 V CMC 0,16 % 500 kHz do 1 MHz od 1 V do 1,5 V CMC 0,32 % 10 Hz do 20 Hz od 1,5 V do 2,2 V CMC 0,056 % 20 Hz do 40 Hz od 1,5 V do 2,2 V CMC 0,019 % 40 Hz do 20 kHz od 1,5 V do 2,2 V CMC 0,0084 % 20 kHz do 50 kHz od 1,5 V do 2,2 V CMC 0,014 % 50 kHz do 100 kHz od 1,5 V do 2,2 V CMC 0,030 % 100 kHz do 300 kHz od 1,5 V do 2,2 V CMC 0,053 % 300 kHz do 500 kHz od 1,5 V do 2,2 V CMC 0,15 % 500 kHz do 1 MHz od 1,5 V do 2,2 V CMC 0,29 % 10 Hz do 20 Hz od 2,2 V do 3 V CMC 0,087 % 20 Hz do 40 Hz od 2,2 V do 3 V CMC 0,028 % 40 Hz do 20 kHz od 2,2 V do 3 V CMC 0,011 % 20 kHz do 50 kHz od 2,2 V do 3 V CMC 0,020 % 50 kHz do 100 kHz od 2,2 V do 3 V CMC 0,042 % 100 kHz do 300 kHz od 2,2 V do 3 V CMC 0,12 % 300 kHz do 500 kHz od 2,2 V do 3 V CMC 0,33 % 500 kHz do 1 MHz od 2,2 V do 3 V CMC 0,67 % 10 Hz do 20 Hz od 3 V do 5 V CMC 0,078 % 20 Hz do 40 Hz od 3 V do 5 V CMC 0,025 % 40 Hz do 20 kHz od 3 V do 5 V CMC 0,099 % 20 kHz do 50 kHz od 3 V do 5 V CMC 0,018 % 50 kHz do 100 kHz od 3 V do 5 V CMC 0,030 % 100 kHz do 300 kHz od 3 V do 5 V CMC 0,11 % 300 kHz do 500 kHz od 3 V do 5 V CMC 0,28 % 500 kHz do 1 MHz od 3 V do 5 V CMC 0,56 % 10 Hz do 20 Hz od 5 V do 10 V CMC 0,067 % 20 Hz do 40 Hz od 5 V do 10 V CMC 0,022 % 40 Hz do 20 kHz od 5 V do 10 V CMC 0,0091 % 20 kHz do 50 kHz od 5 V do 10 V CMC 0,016 % 50 kHz do 100 kHz od 5 V do 10 V CMC 0,033 % 100 kHz do 300 kHz od 5 V do 10 V CMC 0,081 % 300 kHz do 500 kHz od 5 V do 10 V CMC 0,23 % 500 kHz do 1 MHz od 5 V do 10 V CMC 0,45 % 10 Hz do 20 Hz od 10 V do 15 V CMC 0,059 % 20 Hz do 40 Hz od 10 V do 15 V CMC 0,019 % 40 Hz do 20 kHz od 10 V do 15 V CMC 0,0086 % 20 kHz do 50 kHz od 10 V do 15 V CMC 0,014 % 50 kHz do 100 kHz od 10 V do 15 V CMC 0,029 % 100 kHz do 300 kHz od 10 V do 15 V CMC 0,066 % 300 kHz do 500 kHz od 10 V do 15 V CMC 0,19 % 500 kHz do 1 MHz od 10 V do 15 V CMC 0,37 % 10 Hz do 20 Hz od 15 V do 22 V CMC 0,056 % 20 Hz do 40 Hz od 15 V do 22 V CMC 0,019 % 40 Hz do 20 kHz od 15 V do 22 V CMC 0,087 % 20 kHz do 50 kHz od 15 V do 22 V CMC 0,014 % 50 kHz do 100 kHz od 15 V do 22 V CMC 0,029 % 100 kHz do 300 kHz od 15 V do 22 V CMC 0,061 % 300 kHz do 500 kHz od 15 V do 22 V CMC 0,18 % 500 kHz do 1 MHz od 15 V do 22 V CMC 0,34 % 10 Hz do 20 Hz od 22 V do 30 V CMC 0,087 % 20 Hz do 40 Hz od 22 V do 30 V CMC 0,028 % 40 Hz do 20 kHz od 22 V do 30 V CMC 0,013 % 20 kHz do 50 kHz od 22 V do 30 V CMC 0,039 % 50 kHz do 100 kHz od 22 V do 30 V CMC 0,087 % 10 Hz do 20 Hz od 30 V do 50 V CMC 0,078 % 20 Hz do 40 Hz od 30 V do 50 V CMC 0,025 % 40 Hz do 20 kHz od 30 V do 50 V CMC 0,012 % 20 kHz do 50 kHz od 30 V do 50 V CMC 0,034 % 50 kHz do 100 kHz od 30 V do 50 V CMC 0,078 % 10 Hz do 20 Hz od 50 V do 100 V CMC 0,067 % 20 Hz do 40 Hz od 50 V do 100 V CMC 0,022 % 40 Hz do 20 kHz od 50 V do 100 V CMC 0,011 % 20 kHz do 50 kHz od 50 V do 100 V CMC 0,030 % 50 kHz do 100 kHz od 50 V do 100 V CMC 0,067 % 10 Hz do 20 Hz od 100 V do 150 V CMC 0,059 % 20 Hz do 40 Hz od 100 V do 150 V CMC 0,019 % 40 Hz do 20 kHz od 100 V do 150 V CMC 0,010 % 20 kHz do 50 kHz od 100 V do 150 V CMC 0,026 % 50 kHz do 100 kHz od 100 V do 150 V CMC 0,059 % 10 Hz do 20 Hz od 150 V do 220 V CMC 0,057 % 20 Hz do 40 Hz od 150 V do 220 V CMC 0,019 % 40 Hz do 20 kHz od 150 V do 220 V CMC 0,011 % 20 kHz do 50 kHz od 150 V do 220 V CMC 0,027 % 50 kHz do 100 kHz od 150 V do 220 V CMC 0,065 % 10 Hz do 50 Hz od 220 V do 300 V CMC 0,030 % 50 Hz do 1 kHz od 220 V do 300 V CMC 0,012 % 1 kHz do 10 kHz od 220 V do 300 V CMC 0,026 % 10 kHz do 30 kHz od 220 V do 300 V CMC 0,042 % 10 Hz do 50 Hz od 300 V do 400 V CMC 0,030 % 50 Hz do 1 kHz od 300 V do 400 V CMC 0,012 % 1 kHz do 10 kHz od 300 V do 400 V CMC 0,026 % 10 kHz do 30 kHz od 300 V do 400 V CMC 0,042 % 10 Hz do 50 Hz od 400 V do 500 V CMC 0,028 % 50 Hz do 1 kHz od 400 V do 500 V CMC 0,012 % 1 kHz do 10 kHz od 400 V do 500 V CMC 0,025 % 10 kHz do 30 kHz od 400 V do 500 V CMC 0,045 % 10 Hz do 50 Hz od 500 V do 600 V CMC 0,027 % 50 Hz do 1 kHz od 500 V do 600 V CMC 0,011 % 1 kHz do 10 kHz od 500 V do 600 V CMC 0,023 % 10 kHz do 30 kHz od 500 V do 600 V CMC 0,053 % 10 Hz do 50 Hz od 600 V do 700 V CMC 0,028 % 50 Hz do 1 kHz od 600 V do 700 V CMC 0,012 % 1 kHz do 10 kHz od 600 V do 700 V CMC 0,025 % 10 kHz do 30 kHz od 600 V do 700 V CMC 0,068 % 10 Hz do 50 Hz od 700 V do 800 V CMC 0,030 % 50 Hz do 1 kHz od 700 V do 800 V CMC 0,011 % 1 kHz do 10 kHz od 700 V do 800 V CMC 0,028 % 10 kHz do 30 kHz od 700 V do 800 V CMC 0,089 % 10 Hz do 50 Hz od 800 V do 1050 V CMC 0,040 % 50 Hz do 1 kHz od 800 V do 1050 V CMC 0,010 % 1 kHz do 10 kHz od 800 V do 1050 V CMC 0,038 % 10 kHz do 30 kHz od 800 V do 1050 V CMC 0,17 % Stridave napeti / Meridla stejnosmerneho napeti Kalibrace – elektricke veliciny Prime generovani kalibratorem 10 Hz az 50 kHz 0,22 mV az 0,5 mV CMC 4,9 µV 50 kHz az 100 kHz 0,22 mV az 0,5 mV CMC 7,6 µV 10 Hz az 20 Hz 0,5 mV az 1 mV CMC 5,5 µV 20 Hz az 40 Hz 0,5 mV az 1 mV CMC 5,2 µV 40 Hz az 20 kHz 0,5 mV az 1 mV CMC 5,1 µV 20 kHz az 50 kHz 0,5 mV az 1 mV CMC 5,3 µV 50 kHz az 100 kHz 0,5 mV az 1 mV CMC 8,5 µV 10 Hz az 20 Hz 1 mV az 2,2 mV CMC 5,9 µV 20 Hz az 20 kHz 1 mV az 2,2 mV CMC 5,2 µV 20 kHz az 50 kHz 1 mV az 2,2 mV CMC 5,6 µV 50 kHz az 100 kHz 1 mV az 2,2 mV CMC 9,1 µV 100 kHz az 300 kHz 1 mV az 2,2 mV CMC 16 µV 300 kHz az 500 kHz 1 mV az 2,2 mV CMC 30 µV 500 kHz az 1 MHz 1 mV az 2,2 mV CMC 34 µV 10 Hz az 20 Hz 2,2 mV az 3 mV CMC 6,8 µV 20 Hz az 40 Hz 2,2 mV az 3 mV CMC 5,8 µV 40 Hz az 20 kHz 2,2 mV az 3 mV CMC 5,5 µV 20 kHz az 50 kHz 2,2 mV az 3 mV CMC 6,3 µV 50 kHz az 100 kHz 2,2 mV az 3 mV CMC 9,7 µV 100 kHz az 300 kHz 2,2 mV az 3 mV CMC 16 µV 300 kHz az 500 kHz 2,2 mV az 3 mV CMC 31 µV 500 kHz az 1 MHz 2,2 mV az 3 mV CMC 36 µV 10 Hz az 20 Hz 3 mV az 5 mV CMC 8,0 µV 20 Hz az 40 Hz 3 mV az 5 mV CMC 6,4 µV 40 Hz az 20 kHz 3 mV az 5 mV CMC 5,9 µV 20 kHz az 50 kHz 3 mV az 5 mV CMC 7,1 µV 50 kHz az 100 kHz 3 mV az 5 mV CMC 12 µV 100 kHz az 300 kHz 3 mV az 5 mV CMC 18 µV 300 kHz az 500 kHz 3 mV az 5 mV CMC 35 µV 500 kHz az 1 MHz 3 mV az 5 mV CMC 43 µV 10 Hz az 20 Hz 5 mV az 10 mV CMC 12 µV 20 Hz az 40 Hz 5 mV az 10 mV CMC 8,0 µV 40 Hz az 20 kHz 5 mV az 10 mV CMC 7,1 µV 20 kHz az 50 kHz 5 mV az 10 mV CMC 9,4 µV 50 kHz az 100 kHz 5 mV az 10 mV CMC 17 µV 100 kHz az 300 kHz 5 mV az 10 mV CMC 25 µV 300 kHz az 500 kHz 5 mV az 10 mV CMC 44 µV 500 kHz az 1 MHz 5 mV az 10 mV CMC 61 µV 10 Hz az 20 Hz 10 mV az 15 mV CMC 14 µV 20 Hz az 40 Hz 10 mV az 15 mV CMC 8,8 µV 40 Hz az 20 kHz 10 mV az 15 mV CMC 7,3 µV 20 kHz az 50 kHz 10 mV az 15 mV CMC 12 µV 50 kHz az 100 kHz 10 mV az 15 mV CMC 21 µV 100 kHz az 300 kHz 10 mV az 15 mV CMC 31 µV 300 kHz az 500 kHz 10 mV az 15 mV CMC 54 µV 500 kHz az 1 MHz 10 mV az 15 mV CMC 78 µV 10 Hz az 20 Hz 15 mV az 22 mV CMC 18 µV 20 Hz az 40 Hz 15 mV az 22 mV CMC 10 µV 40 Hz az 20 kHz 15 mV az 22 mV CMC 7,7 µV 20 kHz az 50 kHz 15 mV az 22 mV CMC 14 µV 50 kHz az 100 kHz 15 mV az 22 mV CMC 27 µV 100 kHz az 300 kHz 15 mV az 22 mV CMC 39 µV 300 kHz az 500 kHz 15 mV az 22 mV CMC 67 µV 500 kHz az 1 MHz 15 mV az 22 mV CMC 0,11 mV 10 Hz az 20 Hz 22 mV az 30 mV CMC 0,12 % 20 Hz az 40 Hz 22 mV az 30 mV CMC 0,059 % 40 Hz az 20 kHz 22 mV az 30 mV CMC 0,048 % 20 kHz az 50 kHz 22 mV az 30 mV CMC 0,072 % 50 kHz az 100 kHz 22 mV az 30 mV CMC 0,21 % 100 kHz az 300 kHz 22 mV az 30 mV CMC 0,24 % 300 kHz az 500 kHz 22 mV az 30 mV CMC 0,35 % 500 kHz az 1 MHz 22 mV az 30 mV CMC 0,72 % 10 Hz az 20 Hz 30 mV az 50 mV CMC 0,099 % 20 Hz az 40 Hz 30 mV az 50 mV CMC 0,049 % 40 Hz az 20 kHz 30 mV az 50 mV CMC 0,039 % 20 kHz az 50 kHz 30 mV az 50 mV CMC 0,062 % 50 kHz az 100 kHz 30 mV az 50 mV CMC 0,18 % 100 kHz az 300 kHz 30 mV az 50 mV CMC 0,21 % 300 kHz az 500 kHz 30 mV az 50 mV CMC 0,31 % 500 kHz az 1 MHz 30 mV az 50 mV CMC 0,62 % 10 Hz az 20 Hz 50 mV az 100 mV CMC 0,082 % 20 Hz az 40 Hz 50 mV az 100 mV CMC 0,039 % 40 Hz az 20 kHz 50 mV az 100 mV CMC 0,029 % 20 kHz az 50 kHz 50 mV az 100 mV CMC 0,052 % 50 kHz az 100 kHz 50 mV az 100 mV CMC 0,15 % 100 kHz az 300 kHz 50 mV az 100 mV CMC 0,18 % 300 kHz az 500 kHz 50 mV az 100 mV CMC 0,27 % 500 kHz az 1 MHz 50 mV az 100 mV CMC 0,51 % 10 Hz az 20 Hz 100 mV az 150 mV CMC 0,069 % 20 Hz az 40 Hz 100 mV az 150 mV CMC 0,031 % 40 Hz az 20 kHz 100 mV az 150 mV CMC 0,021 % 20 kHz az 50 kHz 100 mV az 150 mV CMC 0,045 % 50 kHz az 100 kHz 100 mV az 150 mV CMC 0,12 % 100 kHz az 300 kHz 100 mV az 150 mV CMC 0,15 % 300 kHz az 500 kHz 100 mV az 150 mV CMC 0,23 % 500 kHz az 1 MHz 100 mV az 150 mV CMC 0,44 % 10 Hz az 20 Hz 150 mV az 220 mV CMC 0,065 % 20 Hz az 40 Hz 150 mV az 220 mV CMC 0,028 % 40 Hz az 20 kHz 150 mV az 220 mV CMC 0,017 % 20 kHz az 50 kHz 150 mV az 220 mV CMC 0,039 % 50 kHz az 100 kHz 150 mV az 220 mV CMC 0,11 % 100 kHz az 300 kHz 150 mV az 220 mV CMC 0,13 % 300 kHz az 500 kHz 150 mV az 220 mV CMC 0,21 % 500 kHz az 1 MHz 150 mV az 220 mV CMC 0,41 % 10 Hz az 20 Hz 220 mV az 300 mV CMC 0,087 % 20 Hz az 40 Hz 220 mV az 300 mV CMC 0,028 % 40 Hz az 20 kHz 220 mV az 300 mV CMC 0,011 % 20 kHz az 50 kHz 220 mV az 300 mV CMC 0,020 % 50 kHz az 100 kHz 220 mV az 300 mV CMC 0,058 % 100 kHz az 300 kHz 220 mV az 300 mV CMC 0,11 % 300 kHz az 500 kHz 220 mV az 300 mV CMC 0,28 % 500 kHz az 1 MHz 220 mV az 300 mV CMC 0,61 % 10 Hz az 20 Hz 300 mV az 500 mV CMC 0,078 % 20 Hz az 40 Hz 300 mV az 500 mV CMC 0,025 % 40 Hz az 20 kHz 300 mV az 500 mV CMC 0,010 % 20 kHz az 50 kHz 300 mV az 500 mV CMC 0,018 % 50 kHz az 100 kHz 300 mV az 500 mV CMC 0,049 % 100 kHz az 300 kHz 300 mV az 500 mV CMC 0,088 % 300 kHz az 500 kHz 300 mV az 500 mV CMC 0,23 % 500 kHz az 1 MHz 300 mV az 500 mV CMC 0,51 % 10 Hz az 20 Hz 500 mV az 1 V CMC 0,067 % 20 Hz az 40 Hz 500 mV az 1 V CMC 0,022 % 40 Hz az 20 kHz 500 mV az 1 V CMC 0,0092 % 20 kHz az 50 kHz 500 mV az 1 V CMC 0,016 % 50 kHz az 100 kHz 500 mV az 1 V CMC 0,040 % 100 kHz az 300 kHz 500 mV az 1 V CMC 0,071 % 300 kHz az 500 kHz 500 mV az 1 V CMC 0,19 % 500 kHz az 1 MHz 500 mV az 1 V CMC 0,40 % 10 Hz az 20 Hz 1 V az 1,5 V CMC 0,059 % 20 Hz az 40 Hz 1 V az 1,5 V CMC 0,019 % 40 Hz az 20 kHz 1 V az 1,5 V CMC 0,0086 % 20 kHz az 50 kHz 1 V az 1,5 V CMC 0,015 % 50 kHz az 100 kHz 1 V az 1,5 V CMC 0,033 % 100 kHz az 300 kHz 1 V az 1,5 V CMC 0,058 % 300 kHz az 500 kHz 1 V az 1,5 V CMC 0,16 % 500 kHz az 1 MHz 1 V az 1,5 V CMC 0,32 % 10 Hz az 20 Hz 1,5 V az 2,2 V CMC 0,056 % 20 Hz az 40 Hz 1,5 V az 2,2 V CMC 0,019 % 40 Hz az 20 kHz 1,5 V az 2,2 V CMC 0,0084 % 20 kHz az 50 kHz 1,5 V az 2,2 V CMC 0,014 % 50 kHz az 100 kHz 1,5 V az 2,2 V CMC 0,030 % 100 kHz az 300 kHz 1,5 V az 2,2 V CMC 0,053 % 300 kHz az 500 kHz 1,5 V az 2,2 V CMC 0,15 % 500 kHz az 1 MHz 1,5 V az 2,2 V CMC 0,29 % 10 Hz az 20 Hz 2,2 V az 3 V CMC 0,087 % 20 Hz az 40 Hz 2,2 V az 3 V CMC 0,028 % 40 Hz az 20 kHz 2,2 V az 3 V CMC 0,011 % 20 kHz az 50 kHz 2,2 V az 3 V CMC 0,020 % 50 kHz az 100 kHz 2,2 V az 3 V CMC 0,042 % 100 kHz az 300 kHz 2,2 V az 3 V CMC 0,12 % 300 kHz az 500 kHz 2,2 V az 3 V CMC 0,33 % 500 kHz az 1 MHz 2,2 V az 3 V CMC 0,67 % 10 Hz az 20 Hz 3 V az 5 V CMC 0,078 % 20 Hz az 40 Hz 3 V az 5 V CMC 0,025 % 40 Hz az 20 kHz 3 V az 5 V CMC 0,099 % 20 kHz az 50 kHz 3 V az 5 V CMC 0,018 % 50 kHz az 100 kHz 3 V az 5 V CMC 0,030 % 100 kHz az 300 kHz 3 V az 5 V CMC 0,11 % 300 kHz az 500 kHz 3 V az 5 V CMC 0,28 % 500 kHz az 1 MHz 3 V az 5 V CMC 0,56 % 10 Hz az 20 Hz 5 V az 10 V CMC 0,067 % 20 Hz az 40 Hz 5 V az 10 V CMC 0,022 % 40 Hz az 20 kHz 5 V az 10 V CMC 0,0091 % 20 kHz az 50 kHz 5 V az 10 V CMC 0,016 % 50 kHz az 100 kHz 5 V az 10 V CMC 0,033 % 100 kHz az 300 kHz 5 V az 10 V CMC 0,081 % 300 kHz az 500 kHz 5 V az 10 V CMC 0,23 % 500 kHz az 1 MHz 5 V az 10 V CMC 0,45 % 10 Hz az 20 Hz 10 V az 15 V CMC 0,059 % 20 Hz az 40 Hz 10 V az 15 V CMC 0,019 % 40 Hz az 20 kHz 10 V az 15 V CMC 0,0086 % 20 kHz az 50 kHz 10 V az 15 V CMC 0,014 % 50 kHz az 100 kHz 10 V az 15 V CMC 0,029 % 100 kHz az 300 kHz 10 V az 15 V CMC 0,066 % 300 kHz az 500 kHz 10 V az 15 V CMC 0,19 % 500 kHz az 1 MHz 10 V az 15 V CMC 0,37 % 10 Hz az 20 Hz 15 V az 22 V CMC 0,056 % 20 Hz az 40 Hz 15 V az 22 V CMC 0,019 % 40 Hz az 20 kHz 15 V az 22 V CMC 0,087 % 20 kHz az 50 kHz 15 V az 22 V CMC 0,014 % 50 kHz az 100 kHz 15 V az 22 V CMC 0,029 % 100 kHz az 300 kHz 15 V az 22 V CMC 0,061 % 300 kHz az 500 kHz 15 V az 22 V CMC 0,18 % 500 kHz az 1 MHz 15 V az 22 V CMC 0,34 % 10 Hz az 20 Hz 22 V az 30 V CMC 0,087 % 20 Hz az 40 Hz 22 V az 30 V CMC 0,028 % 40 Hz az 20 kHz 22 V az 30 V CMC 0,013 % 20 kHz az 50 kHz 22 V az 30 V CMC 0,039 % 50 kHz az 100 kHz 22 V az 30 V CMC 0,087 % 10 Hz az 20 Hz 30 V az 50 V CMC 0,078 % 20 Hz az 40 Hz 30 V az 50 V CMC 0,025 % 40 Hz az 20 kHz 30 V az 50 V CMC 0,012 % 20 kHz az 50 kHz 30 V az 50 V CMC 0,034 % 50 kHz az 100 kHz 30 V az 50 V CMC 0,078 % 10 Hz az 20 Hz 50 V az 100 V CMC 0,067 % 20 Hz az 40 Hz 50 V az 100 V CMC 0,022 % 40 Hz az 20 kHz 50 V az 100 V CMC 0,011 % 20 kHz az 50 kHz 50 V az 100 V CMC 0,030 % 50 kHz az 100 kHz 50 V az 100 V CMC 0,067 % 10 Hz az 20 Hz 100 V az 150 V CMC 0,059 % 20 Hz az 40 Hz 100 V az 150 V CMC 0,019 % 40 Hz az 20 kHz 100 V az 150 V CMC 0,010 % 20 kHz az 50 kHz 100 V az 150 V CMC 0,026 % 50 kHz az 100 kHz 100 V az 150 V CMC 0,059 % 10 Hz az 20 Hz 150 V az 220 V CMC 0,057 % 20 Hz az 40 Hz 150 V az 220 V CMC 0,019 % 40 Hz az 20 kHz 150 V az 220 V CMC 0,011 % 20 kHz az 50 kHz 150 V az 220 V CMC 0,027 % 50 kHz az 100 kHz 150 V az 220 V CMC 0,065 % 10 Hz az 50 Hz 220 V az 300 V CMC 0,030 % 50 Hz az 1 kHz 220 V az 300 V CMC 0,012 % 1 kHz az 10 kHz 220 V az 300 V CMC 0,026 % 10 kHz az 30 kHz 220 V az 300 V CMC 0,042 % 10 Hz az 50 Hz 300 V az 400 V CMC 0,030 % 50 Hz az 1 kHz 300 V az 400 V CMC 0,012 % 1 kHz az 10 kHz 300 V az 400 V CMC 0,026 % 10 kHz az 30 kHz 300 V az 400 V CMC 0,042 % 10 Hz az 50 Hz 400 V az 500 V CMC 0,028 % 50 Hz az 1 kHz 400 V az 500 V CMC 0,012 % 1 kHz az 10 kHz 400 V az 500 V CMC 0,025 % 10 kHz az 30 kHz 400 V az 500 V CMC 0,045 % 10 Hz az 50 Hz 500 V az 600 V CMC 0,027 % 50 Hz az 1 kHz 500 V az 600 V CMC 0,011 % 1 kHz az 10 kHz 500 V az 600 V CMC 0,023 % 10 kHz az 30 kHz 500 V az 600 V CMC 0,053 % 10 Hz az 50 Hz 600 V az 700 V CMC 0,028 % 50 Hz az 1 kHz 600 V az 700 V CMC 0,012 % 1 kHz az 10 kHz 600 V az 700 V CMC 0,025 % 10 kHz az 30 kHz 600 V az 700 V CMC 0,068 % 10 Hz az 50 Hz 700 V az 800 V CMC 0,030 % 50 Hz az 1 kHz 700 V az 800 V CMC 0,011 % 1 kHz az 10 kHz 700 V az 800 V CMC 0,028 % 10 kHz az 30 kHz 700 V az 800 V CMC 0,089 % 10 Hz az 50 Hz 800 V az 1050 V CMC 0,040 % 50 Hz az 1 kHz 800 V az 1050 V CMC 0,010 % 1 kHz az 10 kHz 800 V az 1050 V CMC 0,038 % 10 kHz az 30 kHz 800 V az 1050 V CMC 0,17 % TP2, TP21","search_en":"AC voltage / DC voltage meters Calibration – electrical quantities Direct generation with a calibrator 10 Hz to 50 kHz 0,22 mV to 0,5 mV CMC 4,9 µV 50 kHz to 100 kHz 0,22 mV to 0,5 mV CMC 7,6 µV 10 Hz to 20 Hz 0,5 mV to 1 mV CMC 5,5 µV 20 Hz to 40 Hz 0,5 mV to 1 mV CMC 5,2 µV 40 Hz to 20 kHz 0,5 mV to 1 mV CMC 5,1 µV 20 kHz to 50 kHz 0,5 mV to 1 mV CMC 5,3 µV 50 kHz to 100 kHz 0,5 mV to 1 mV CMC 8,5 µV 10 Hz to 20 Hz 1 mV to 2,2 mV CMC 5,9 µV 20 Hz to 20 kHz 1 mV to 2,2 mV CMC 5,2 µV 20 kHz to 50 kHz 1 mV to 2,2 mV CMC 5,6 µV 50 kHz to 100 kHz 1 mV to 2,2 mV CMC 9,1 µV 100 kHz to 300 kHz 1 mV to 2,2 mV CMC 16 µV 300 kHz to 500 kHz 1 mV to 2,2 mV CMC 30 µV 500 kHz to 1 MHz 1 mV to 2,2 mV CMC 34 µV 10 Hz to 20 Hz 2,2 mV to 3 mV CMC 6,8 µV 20 Hz to 40 Hz 2,2 mV to 3 mV CMC 5,8 µV 40 Hz to 20 kHz 2,2 mV to 3 mV CMC 5,5 µV 20 kHz to 50 kHz 2,2 mV to 3 mV CMC 6,3 µV 50 kHz to 100 kHz 2,2 mV to 3 mV CMC 9,7 µV 100 kHz to 300 kHz 2,2 mV to 3 mV CMC 16 µV 300 kHz to 500 kHz 2,2 mV to 3 mV CMC 31 µV 500 kHz to 1 MHz 2,2 mV to 3 mV CMC 36 µV 10 Hz to 20 Hz 3 mV to 5 mV CMC 8,0 µV 20 Hz to 40 Hz 3 mV to 5 mV CMC 6,4 µV 40 Hz to 20 kHz 3 mV to 5 mV CMC 5,9 µV 20 kHz to 50 kHz 3 mV to 5 mV CMC 7,1 µV 50 kHz to 100 kHz 3 mV to 5 mV CMC 12 µV 100 kHz to 300 kHz 3 mV to 5 mV CMC 18 µV 300 kHz to 500 kHz 3 mV to 5 mV CMC 35 µV 500 kHz to 1 MHz 3 mV to 5 mV CMC 43 µV 10 Hz to 20 Hz 5 mV to 10 mV CMC 12 µV 20 Hz to 40 Hz 5 mV to 10 mV CMC 8,0 µV 40 Hz to 20 kHz 5 mV to 10 mV CMC 7,1 µV 20 kHz to 50 kHz 5 mV to 10 mV CMC 9,4 µV 50 kHz to 100 kHz 5 mV to 10 mV CMC 17 µV 100 kHz to 300 kHz 5 mV to 10 mV CMC 25 µV 300 kHz to 500 kHz 5 mV to 10 mV CMC 44 µV 500 kHz to 1 MHz 5 mV to 10 mV CMC 61 µV 10 Hz to 20 Hz 10 mV to 15 mV CMC 14 µV 20 Hz to 40 Hz 10 mV to 15 mV CMC 8,8 µV 40 Hz to 20 kHz 10 mV to 15 mV CMC 7,3 µV 20 kHz to 50 kHz 10 mV to 15 mV CMC 12 µV 50 kHz to 100 kHz 10 mV to 15 mV CMC 21 µV 100 kHz to 300 kHz 10 mV to 15 mV CMC 31 µV 300 kHz to 500 kHz 10 mV to 15 mV CMC 54 µV 500 kHz to 1 MHz 10 mV to 15 mV CMC 78 µV 10 Hz to 20 Hz 15 mV to 22 mV CMC 18 µV 20 Hz to 40 Hz 15 mV to 22 mV CMC 10 µV 40 Hz to 20 kHz 15 mV to 22 mV CMC 7,7 µV 20 kHz to 50 kHz 15 mV to 22 mV CMC 14 µV 50 kHz to 100 kHz 15 mV to 22 mV CMC 27 µV 100 kHz to 300 kHz 15 mV to 22 mV CMC 39 µV 300 kHz to 500 kHz 15 mV to 22 mV CMC 67 µV 500 kHz to 1 MHz 15 mV to 22 mV CMC 0,11 mV 10 Hz to 20 Hz 22 mV to 30 mV CMC 0,12 % 20 Hz to 40 Hz 22 mV to 30 mV CMC 0,059 % 40 Hz to 20 kHz 22 mV to 30 mV CMC 0,048 % 20 kHz to 50 kHz 22 mV to 30 mV CMC 0,072 % 50 kHz to 100 kHz 22 mV to 30 mV CMC 0,21 % 100 kHz to 300 kHz 22 mV to 30 mV CMC 0,24 % 300 kHz to 500 kHz 22 mV to 30 mV CMC 0,35 % 500 kHz to 1 MHz 22 mV to 30 mV CMC 0,72 % 10 Hz to 20 Hz 30 mV to 50 mV CMC 0,099 % 20 Hz to 40 Hz 30 mV to 50 mV CMC 0,049 % 40 Hz to 20 kHz 30 mV to 50 mV CMC 0,039 % 20 kHz to 50 kHz 30 mV to 50 mV CMC 0,062 % 50 kHz to 100 kHz 30 mV to 50 mV CMC 0,18 % 100 kHz to 300 kHz 30 mV to 50 mV CMC 0,21 % 300 kHz to 500 kHz 30 mV to 50 mV CMC 0,31 % 500 kHz to 1 MHz 30 mV to 50 mV CMC 0,62 % 10 Hz to 20 Hz 50 mV to 100 mV CMC 0,082 % 20 Hz to 40 Hz 50 mV to 100 mV CMC 0,039 % 40 Hz to 20 kHz 50 mV to 100 mV CMC 0,029 % 20 kHz to 50 kHz 50 mV to 100 mV CMC 0,052 % 50 kHz to 100 kHz 50 mV to 100 mV CMC 0,15 % 100 kHz to 300 kHz 50 mV to 100 mV CMC 0,18 % 300 kHz to 500 kHz 50 mV to 100 mV CMC 0,27 % 500 kHz to 1 MHz 50 mV to 100 mV CMC 0,51 % 10 Hz to 20 Hz 100 mV to 150 mV CMC 0,069 % 20 Hz to 40 Hz 100 mV to 150 mV CMC 0,031 % 40 Hz to 20 kHz 100 mV to 150 mV CMC 0,021 % 20 kHz to 50 kHz 100 mV to 150 mV CMC 0,045 % 50 kHz to 100 kHz 100 mV to 150 mV CMC 0,12 % 100 kHz to 300 kHz 100 mV to 150 mV CMC 0,15 % 300 kHz to 500 kHz 100 mV to 150 mV CMC 0,23 % 500 kHz to 1 MHz 100 mV to 150 mV CMC 0,44 % 10 Hz to 20 Hz 150 mV to 220 mV CMC 0,065 % 20 Hz to 40 Hz 150 mV to 220 mV CMC 0,028 % 40 Hz to 20 kHz 150 mV to 220 mV CMC 0,017 % 20 kHz to 50 kHz 150 mV to 220 mV CMC 0,039 % 50 kHz to 100 kHz 150 mV to 220 mV CMC 0,11 % 100 kHz to 300 kHz 150 mV to 220 mV CMC 0,13 % 300 kHz to 500 kHz 150 mV to 220 mV CMC 0,21 % 500 kHz to 1 MHz 150 mV to 220 mV CMC 0,41 % 10 Hz to 20 Hz 220 mV to 300 mV CMC 0,087 % 20 Hz to 40 Hz 220 mV to 300 mV CMC 0,028 % 40 Hz to 20 kHz 220 mV to 300 mV CMC 0,011 % 20 kHz to 50 kHz 220 mV to 300 mV CMC 0,020 % 50 kHz to 100 kHz 220 mV to 300 mV CMC 0,058 % 100 kHz to 300 kHz 220 mV to 300 mV CMC 0,11 % 300 kHz to 500 kHz 220 mV to 300 mV CMC 0,28 % 500 kHz to 1 MHz 220 mV to 300 mV CMC 0,61 % 10 Hz to 20 Hz 300 mV to 500 mV CMC 0,078 % 20 Hz to 40 Hz 300 mV to 500 mV CMC 0,025 % 40 Hz to 20 kHz 300 mV to 500 mV CMC 0,010 % 20 kHz to 50 kHz 300 mV to 500 mV CMC 0,018 % 50 kHz to 100 kHz 300 mV to 500 mV CMC 0,049 % 100 kHz to 300 kHz 300 mV to 500 mV CMC 0,088 % 300 kHz to 500 kHz 300 mV to 500 mV CMC 0,23 % 500 kHz to 1 MHz 300 mV to 500 mV CMC 0,51 % 10 Hz to 20 Hz 500 mV to 1 V CMC 0,067 % 20 Hz to 40 Hz 500 mV to 1 V CMC 0,022 % 40 Hz to 20 kHz 500 mV to 1 V CMC 0,0092 % 20 kHz to 50 kHz 500 mV to 1 V CMC 0,016 % 50 kHz to 100 kHz 500 mV to 1 V CMC 0,040 % 100 kHz to 300 kHz 500 mV to 1 V CMC 0,071 % 300 kHz to 500 kHz 500 mV to 1 V CMC 0,19 % 500 kHz to 1 MHz 500 mV to 1 V CMC 0,40 % 10 Hz to 20 Hz 1 V to 1,5 V CMC 0,059 % 20 Hz to 40 Hz 1 V to 1,5 V CMC 0,019 % 40 Hz to 20 kHz 1 V to 1,5 V CMC 0,0086 % 20 kHz to 50 kHz 1 V to 1,5 V CMC 0,015 % 50 kHz to 100 kHz 1 V to 1,5 V CMC 0,033 % 100 kHz to 300 kHz 1 V to 1,5 V CMC 0,058 % 300 kHz to 500 kHz 1 V to 1,5 V CMC 0,16 % 500 kHz to 1 MHz 1 V to 1,5 V CMC 0,32 % 10 Hz to 20 Hz 1,5 V to 2,2 V CMC 0,056 % 20 Hz to 40 Hz 1,5 V to 2,2 V CMC 0,019 % 40 Hz to 20 kHz 1,5 V to 2,2 V CMC 0,0084 % 20 kHz to 50 kHz 1,5 V to 2,2 V CMC 0,014 % 50 kHz to 100 kHz 1,5 V to 2,2 V CMC 0,030 % 100 kHz to 300 kHz 1,5 V to 2,2 V CMC 0,053 % 300 kHz to 500 kHz 1,5 V to 2,2 V CMC 0,15 % 500 kHz to 1 MHz 1,5 V to 2,2 V CMC 0,29 % 10 Hz to 20 Hz 2,2 V to 3 V CMC 0,087 % 20 Hz to 40 Hz 2,2 V to 3 V CMC 0,028 % 40 Hz to 20 kHz 2,2 V to 3 V CMC 0,011 % 20 kHz to 50 kHz 2,2 V to 3 V CMC 0,020 % 50 kHz to 100 kHz 2,2 V to 3 V CMC 0,042 % 100 kHz to 300 kHz 2,2 V to 3 V CMC 0,12 % 300 kHz to 500 kHz 2,2 V to 3 V CMC 0,33 % 500 kHz to 1 MHz 2,2 V to 3 V CMC 0,67 % 10 Hz to 20 Hz 3 V to 5 V CMC 0,078 % 20 Hz to 40 Hz 3 V to 5 V CMC 0,025 % 40 Hz to 20 kHz 3 V to 5 V CMC 0,099 % 20 kHz to 50 kHz 3 V to 5 V CMC 0,018 % 50 kHz to 100 kHz 3 V to 5 V CMC 0,030 % 100 kHz to 300 kHz 3 V to 5 V CMC 0,11 % 300 kHz to 500 kHz 3 V to 5 V CMC 0,28 % 500 kHz to 1 MHz 3 V to 5 V CMC 0,56 % 10 Hz to 20 Hz 5 V to 10 V CMC 0,067 % 20 Hz to 40 Hz 5 V to 10 V CMC 0,022 % 40 Hz to 20 kHz 5 V to 10 V CMC 0,0091 % 20 kHz to 50 kHz 5 V to 10 V CMC 0,016 % 50 kHz to 100 kHz 5 V to 10 V CMC 0,033 % 100 kHz to 300 kHz 5 V to 10 V CMC 0,081 % 300 kHz to 500 kHz 5 V to 10 V CMC 0,23 % 500 kHz to 1 MHz 5 V to 10 V CMC 0,45 % 10 Hz to 20 Hz 10 V to 15 V CMC 0,059 % 20 Hz to 40 Hz 10 V to 15 V CMC 0,019 % 40 Hz to 20 kHz 10 V to 15 V CMC 0,0086 % 20 kHz to 50 kHz 10 V to 15 V CMC 0,014 % 50 kHz to 100 kHz 10 V to 15 V CMC 0,029 % 100 kHz to 300 kHz 10 V to 15 V CMC 0,066 % 300 kHz to 500 kHz 10 V to 15 V CMC 0,19 % 500 kHz to 1 MHz 10 V to 15 V CMC 0,37 % 10 Hz to 20 Hz 15 V to 22 V CMC 0,056 % 20 Hz to 40 Hz 15 V to 22 V CMC 0,019 % 40 Hz to 20 kHz 15 V to 22 V CMC 0,087 % 20 kHz to 50 kHz 15 V to 22 V CMC 0,014 % 50 kHz to 100 kHz 15 V to 22 V CMC 0,029 % 100 kHz to 300 kHz 15 V to 22 V CMC 0,061 % 300 kHz to 500 kHz 15 V to 22 V CMC 0,18 % 500 kHz to 1 MHz 15 V to 22 V CMC 0,34 % 10 Hz to 20 Hz 22 V to 30 V CMC 0,087 % 20 Hz to 40 Hz 22 V to 30 V CMC 0,028 % 40 Hz to 20 kHz 22 V to 30 V CMC 0,013 % 20 kHz to 50 kHz 22 V to 30 V CMC 0,039 % 50 kHz to 100 kHz 22 V to 30 V CMC 0,087 % 10 Hz to 20 Hz 30 V to 50 V CMC 0,078 % 20 Hz to 40 Hz 30 V to 50 V CMC 0,025 % 40 Hz to 20 kHz 30 V to 50 V CMC 0,012 % 20 kHz to 50 kHz 30 V to 50 V CMC 0,034 % 50 kHz to 100 kHz 30 V to 50 V CMC 0,078 % 10 Hz to 20 Hz 50 V to 100 V CMC 0,067 % 20 Hz to 40 Hz 50 V to 100 V CMC 0,022 % 40 Hz to 20 kHz 50 V to 100 V CMC 0,011 % 20 kHz to 50 kHz 50 V to 100 V CMC 0,030 % 50 kHz to 100 kHz 50 V to 100 V CMC 0,067 % 10 Hz to 20 Hz 100 V to 150 V CMC 0,059 % 20 Hz to 40 Hz 100 V to 150 V CMC 0,019 % 40 Hz to 20 kHz 100 V to 150 V CMC 0,010 % 20 kHz to 50 kHz 100 V to 150 V CMC 0,026 % 50 kHz to 100 kHz 100 V to 150 V CMC 0,059 % 10 Hz to 20 Hz 150 V to 220 V CMC 0,057 % 20 Hz to 40 Hz 150 V to 220 V CMC 0,019 % 40 Hz to 20 kHz 150 V to 220 V CMC 0,011 % 20 kHz to 50 kHz 150 V to 220 V CMC 0,027 % 50 kHz to 100 kHz 150 V to 220 V CMC 0,065 % 10 Hz to 50 Hz 220 V to 300 V CMC 0,030 % 50 Hz to 1 kHz 220 V to 300 V CMC 0,012 % 1 kHz to 10 kHz 220 V to 300 V CMC 0,026 % 10 kHz to 30 kHz 220 V to 300 V CMC 0,042 % 10 Hz to 50 Hz 300 V to 400 V CMC 0,030 % 50 Hz to 1 kHz 300 V to 400 V CMC 0,012 % 1 kHz to 10 kHz 300 V to 400 V CMC 0,026 % 10 kHz to 30 kHz 300 V to 400 V CMC 0,042 % 10 Hz to 50 Hz 400 V to 500 V CMC 0,028 % 50 Hz to 1 kHz 400 V to 500 V CMC 0,012 % 1 kHz to 10 kHz 400 V to 500 V CMC 0,025 % 10 kHz to 30 kHz 400 V to 500 V CMC 0,045 % 10 Hz to 50 Hz 500 V to 600 V CMC 0,027 % 50 Hz to 1 kHz 500 V to 600 V CMC 0,011 % 1 kHz to 10 kHz 500 V to 600 V CMC 0,023 % 10 kHz to 30 kHz 500 V to 600 V CMC 0,053 % 10 Hz to 50 Hz 600 V to 700 V CMC 0,028 % 50 Hz to 1 kHz 600 V to 700 V CMC 0,012 % 1 kHz to 10 kHz 600 V to 700 V CMC 0,025 % 10 kHz to 30 kHz 600 V to 700 V CMC 0,068 % 10 Hz to 50 Hz 700 V to 800 V CMC 0,030 % 50 Hz to 1 kHz 700 V to 800 V CMC 0,011 % 1 kHz to 10 kHz 700 V to 800 V CMC 0,028 % 10 kHz to 30 kHz 700 V to 800 V CMC 0,089 % 10 Hz to 50 Hz 800 V to 1050 V CMC 0,040 % 50 Hz to 1 kHz 800 V to 1050 V CMC 0,010 % 1 kHz to 10 kHz 800 V to 1050 V CMC 0,038 % 10 kHz to 30 kHz 800 V to 1050 V CMC 0,17 % TP2, TP21","search_zh":"交流电压 / 直流电压测量仪器 校准 – 电学量 用校准器直接产生 10 Hz 至 50 kHz 0,22 mV 至 0,5 mV CMC 4,9 µV 50 kHz 至 100 kHz 0,22 mV 至 0,5 mV CMC 7,6 µV 10 Hz 至 20 Hz 0,5 mV 至 1 mV CMC 5,5 µV 20 Hz 至 40 Hz 0,5 mV 至 1 mV CMC 5,2 µV 40 Hz 至 20 kHz 0,5 mV 至 1 mV CMC 5,1 µV 20 kHz 至 50 kHz 0,5 mV 至 1 mV CMC 5,3 µV 50 kHz 至 100 kHz 0,5 mV 至 1 mV CMC 8,5 µV 10 Hz 至 20 Hz 1 mV 至 2,2 mV CMC 5,9 µV 20 Hz 至 20 kHz 1 mV 至 2,2 mV CMC 5,2 µV 20 kHz 至 50 kHz 1 mV 至 2,2 mV CMC 5,6 µV 50 kHz 至 100 kHz 1 mV 至 2,2 mV CMC 9,1 µV 100 kHz 至 300 kHz 1 mV 至 2,2 mV CMC 16 µV 300 kHz 至 500 kHz 1 mV 至 2,2 mV CMC 30 µV 500 kHz 至 1 MHz 1 mV 至 2,2 mV CMC 34 µV 10 Hz 至 20 Hz 2,2 mV 至 3 mV CMC 6,8 µV 20 Hz 至 40 Hz 2,2 mV 至 3 mV CMC 5,8 µV 40 Hz 至 20 kHz 2,2 mV 至 3 mV CMC 5,5 µV 20 kHz 至 50 kHz 2,2 mV 至 3 mV CMC 6,3 µV 50 kHz 至 100 kHz 2,2 mV 至 3 mV CMC 9,7 µV 100 kHz 至 300 kHz 2,2 mV 至 3 mV CMC 16 µV 300 kHz 至 500 kHz 2,2 mV 至 3 mV CMC 31 µV 500 kHz 至 1 MHz 2,2 mV 至 3 mV CMC 36 µV 10 Hz 至 20 Hz 3 mV 至 5 mV CMC 8,0 µV 20 Hz 至 40 Hz 3 mV 至 5 mV CMC 6,4 µV 40 Hz 至 20 kHz 3 mV 至 5 mV CMC 5,9 µV 20 kHz 至 50 kHz 3 mV 至 5 mV CMC 7,1 µV 50 kHz 至 100 kHz 3 mV 至 5 mV CMC 12 µV 100 kHz 至 300 kHz 3 mV 至 5 mV CMC 18 µV 300 kHz 至 500 kHz 3 mV 至 5 mV CMC 35 µV 500 kHz 至 1 MHz 3 mV 至 5 mV CMC 43 µV 10 Hz 至 20 Hz 5 mV 至 10 mV CMC 12 µV 20 Hz 至 40 Hz 5 mV 至 10 mV CMC 8,0 µV 40 Hz 至 20 kHz 5 mV 至 10 mV CMC 7,1 µV 20 kHz 至 50 kHz 5 mV 至 10 mV CMC 9,4 µV 50 kHz 至 100 kHz 5 mV 至 10 mV CMC 17 µV 100 kHz 至 300 kHz 5 mV 至 10 mV CMC 25 µV 300 kHz 至 500 kHz 5 mV 至 10 mV CMC 44 µV 500 kHz 至 1 MHz 5 mV 至 10 mV CMC 61 µV 10 Hz 至 20 Hz 10 mV 至 15 mV CMC 14 µV 20 Hz 至 40 Hz 10 mV 至 15 mV CMC 8,8 µV 40 Hz 至 20 kHz 10 mV 至 15 mV CMC 7,3 µV 20 kHz 至 50 kHz 10 mV 至 15 mV CMC 12 µV 50 kHz 至 100 kHz 10 mV 至 15 mV CMC 21 µV 100 kHz 至 300 kHz 10 mV 至 15 mV CMC 31 µV 300 kHz 至 500 kHz 10 mV 至 15 mV CMC 54 µV 500 kHz 至 1 MHz 10 mV 至 15 mV CMC 78 µV 10 Hz 至 20 Hz 15 mV 至 22 mV CMC 18 µV 20 Hz 至 40 Hz 15 mV 至 22 mV CMC 10 µV 40 Hz 至 20 kHz 15 mV 至 22 mV CMC 7,7 µV 20 kHz 至 50 kHz 15 mV 至 22 mV CMC 14 µV 50 kHz 至 100 kHz 15 mV 至 22 mV CMC 27 µV 100 kHz 至 300 kHz 15 mV 至 22 mV CMC 39 µV 300 kHz 至 500 kHz 15 mV 至 22 mV CMC 67 µV 500 kHz 至 1 MHz 15 mV 至 22 mV CMC 0,11 mV 10 Hz 至 20 Hz 22 mV 至 30 mV CMC 0,12 % 20 Hz 至 40 Hz 22 mV 至 30 mV CMC 0,059 % 40 Hz 至 20 kHz 22 mV 至 30 mV CMC 0,048 % 20 kHz 至 50 kHz 22 mV 至 30 mV CMC 0,072 % 50 kHz 至 100 kHz 22 mV 至 30 mV CMC 0,21 % 100 kHz 至 300 kHz 22 mV 至 30 mV CMC 0,24 % 300 kHz 至 500 kHz 22 mV 至 30 mV CMC 0,35 % 500 kHz 至 1 MHz 22 mV 至 30 mV CMC 0,72 % 10 Hz 至 20 Hz 30 mV 至 50 mV CMC 0,099 % 20 Hz 至 40 Hz 30 mV 至 50 mV CMC 0,049 % 40 Hz 至 20 kHz 30 mV 至 50 mV CMC 0,039 % 20 kHz 至 50 kHz 30 mV 至 50 mV CMC 0,062 % 50 kHz 至 100 kHz 30 mV 至 50 mV CMC 0,18 % 100 kHz 至 300 kHz 30 mV 至 50 mV CMC 0,21 % 300 kHz 至 500 kHz 30 mV 至 50 mV CMC 0,31 % 500 kHz 至 1 MHz 30 mV 至 50 mV CMC 0,62 % 10 Hz 至 20 Hz 50 mV 至 100 mV CMC 0,082 % 20 Hz 至 40 Hz 50 mV 至 100 mV CMC 0,039 % 40 Hz 至 20 kHz 50 mV 至 100 mV CMC 0,029 % 20 kHz 至 50 kHz 50 mV 至 100 mV CMC 0,052 % 50 kHz 至 100 kHz 50 mV 至 100 mV CMC 0,15 % 100 kHz 至 300 kHz 50 mV 至 100 mV CMC 0,18 % 300 kHz 至 500 kHz 50 mV 至 100 mV CMC 0,27 % 500 kHz 至 1 MHz 50 mV 至 100 mV CMC 0,51 % 10 Hz 至 20 Hz 100 mV 至 150 mV CMC 0,069 % 20 Hz 至 40 Hz 100 mV 至 150 mV CMC 0,031 % 40 Hz 至 20 kHz 100 mV 至 150 mV CMC 0,021 % 20 kHz 至 50 kHz 100 mV 至 150 mV CMC 0,045 % 50 kHz 至 100 kHz 100 mV 至 150 mV CMC 0,12 % 100 kHz 至 300 kHz 100 mV 至 150 mV CMC 0,15 % 300 kHz 至 500 kHz 100 mV 至 150 mV CMC 0,23 % 500 kHz 至 1 MHz 100 mV 至 150 mV CMC 0,44 % 10 Hz 至 20 Hz 150 mV 至 220 mV CMC 0,065 % 20 Hz 至 40 Hz 150 mV 至 220 mV CMC 0,028 % 40 Hz 至 20 kHz 150 mV 至 220 mV CMC 0,017 % 20 kHz 至 50 kHz 150 mV 至 220 mV CMC 0,039 % 50 kHz 至 100 kHz 150 mV 至 220 mV CMC 0,11 % 100 kHz 至 300 kHz 150 mV 至 220 mV CMC 0,13 % 300 kHz 至 500 kHz 150 mV 至 220 mV CMC 0,21 % 500 kHz 至 1 MHz 150 mV 至 220 mV CMC 0,41 % 10 Hz 至 20 Hz 220 mV 至 300 mV CMC 0,087 % 20 Hz 至 40 Hz 220 mV 至 300 mV CMC 0,028 % 40 Hz 至 20 kHz 220 mV 至 300 mV CMC 0,011 % 20 kHz 至 50 kHz 220 mV 至 300 mV CMC 0,020 % 50 kHz 至 100 kHz 220 mV 至 300 mV CMC 0,058 % 100 kHz 至 300 kHz 220 mV 至 300 mV CMC 0,11 % 300 kHz 至 500 kHz 220 mV 至 300 mV CMC 0,28 % 500 kHz 至 1 MHz 220 mV 至 300 mV CMC 0,61 % 10 Hz 至 20 Hz 300 mV 至 500 mV CMC 0,078 % 20 Hz 至 40 Hz 300 mV 至 500 mV CMC 0,025 % 40 Hz 至 20 kHz 300 mV 至 500 mV CMC 0,010 % 20 kHz 至 50 kHz 300 mV 至 500 mV CMC 0,018 % 50 kHz 至 100 kHz 300 mV 至 500 mV CMC 0,049 % 100 kHz 至 300 kHz 300 mV 至 500 mV CMC 0,088 % 300 kHz 至 500 kHz 300 mV 至 500 mV CMC 0,23 % 500 kHz 至 1 MHz 300 mV 至 500 mV CMC 0,51 % 10 Hz 至 20 Hz 500 mV 至 1 V CMC 0,067 % 20 Hz 至 40 Hz 500 mV 至 1 V CMC 0,022 % 40 Hz 至 20 kHz 500 mV 至 1 V CMC 0,0092 % 20 kHz 至 50 kHz 500 mV 至 1 V CMC 0,016 % 50 kHz 至 100 kHz 500 mV 至 1 V CMC 0,040 % 100 kHz 至 300 kHz 500 mV 至 1 V CMC 0,071 % 300 kHz 至 500 kHz 500 mV 至 1 V CMC 0,19 % 500 kHz 至 1 MHz 500 mV 至 1 V CMC 0,40 % 10 Hz 至 20 Hz 1 V 至 1,5 V CMC 0,059 % 20 Hz 至 40 Hz 1 V 至 1,5 V CMC 0,019 % 40 Hz 至 20 kHz 1 V 至 1,5 V CMC 0,0086 % 20 kHz 至 50 kHz 1 V 至 1,5 V CMC 0,015 % 50 kHz 至 100 kHz 1 V 至 1,5 V CMC 0,033 % 100 kHz 至 300 kHz 1 V 至 1,5 V CMC 0,058 % 300 kHz 至 500 kHz 1 V 至 1,5 V CMC 0,16 % 500 kHz 至 1 MHz 1 V 至 1,5 V CMC 0,32 % 10 Hz 至 20 Hz 1,5 V 至 2,2 V CMC 0,056 % 20 Hz 至 40 Hz 1,5 V 至 2,2 V CMC 0,019 % 40 Hz 至 20 kHz 1,5 V 至 2,2 V CMC 0,0084 % 20 kHz 至 50 kHz 1,5 V 至 2,2 V CMC 0,014 % 50 kHz 至 100 kHz 1,5 V 至 2,2 V CMC 0,030 % 100 kHz 至 300 kHz 1,5 V 至 2,2 V CMC 0,053 % 300 kHz 至 500 kHz 1,5 V 至 2,2 V CMC 0,15 % 500 kHz 至 1 MHz 1,5 V 至 2,2 V CMC 0,29 % 10 Hz 至 20 Hz 2,2 V 至 3 V CMC 0,087 % 20 Hz 至 40 Hz 2,2 V 至 3 V CMC 0,028 % 40 Hz 至 20 kHz 2,2 V 至 3 V CMC 0,011 % 20 kHz 至 50 kHz 2,2 V 至 3 V CMC 0,020 % 50 kHz 至 100 kHz 2,2 V 至 3 V CMC 0,042 % 100 kHz 至 300 kHz 2,2 V 至 3 V CMC 0,12 % 300 kHz 至 500 kHz 2,2 V 至 3 V CMC 0,33 % 500 kHz 至 1 MHz 2,2 V 至 3 V CMC 0,67 % 10 Hz 至 20 Hz 3 V 至 5 V CMC 0,078 % 20 Hz 至 40 Hz 3 V 至 5 V CMC 0,025 % 40 Hz 至 20 kHz 3 V 至 5 V CMC 0,099 % 20 kHz 至 50 kHz 3 V 至 5 V CMC 0,018 % 50 kHz 至 100 kHz 3 V 至 5 V CMC 0,030 % 100 kHz 至 300 kHz 3 V 至 5 V CMC 0,11 % 300 kHz 至 500 kHz 3 V 至 5 V CMC 0,28 % 500 kHz 至 1 MHz 3 V 至 5 V CMC 0,56 % 10 Hz 至 20 Hz 5 V 至 10 V CMC 0,067 % 20 Hz 至 40 Hz 5 V 至 10 V CMC 0,022 % 40 Hz 至 20 kHz 5 V 至 10 V CMC 0,0091 % 20 kHz 至 50 kHz 5 V 至 10 V CMC 0,016 % 50 kHz 至 100 kHz 5 V 至 10 V CMC 0,033 % 100 kHz 至 300 kHz 5 V 至 10 V CMC 0,081 % 300 kHz 至 500 kHz 5 V 至 10 V CMC 0,23 % 500 kHz 至 1 MHz 5 V 至 10 V CMC 0,45 % 10 Hz 至 20 Hz 10 V 至 15 V CMC 0,059 % 20 Hz 至 40 Hz 10 V 至 15 V CMC 0,019 % 40 Hz 至 20 kHz 10 V 至 15 V CMC 0,0086 % 20 kHz 至 50 kHz 10 V 至 15 V CMC 0,014 % 50 kHz 至 100 kHz 10 V 至 15 V CMC 0,029 % 100 kHz 至 300 kHz 10 V 至 15 V CMC 0,066 % 300 kHz 至 500 kHz 10 V 至 15 V CMC 0,19 % 500 kHz 至 1 MHz 10 V 至 15 V CMC 0,37 % 10 Hz 至 20 Hz 15 V 至 22 V CMC 0,056 % 20 Hz 至 40 Hz 15 V 至 22 V CMC 0,019 % 40 Hz 至 20 kHz 15 V 至 22 V CMC 0,087 % 20 kHz 至 50 kHz 15 V 至 22 V CMC 0,014 % 50 kHz 至 100 kHz 15 V 至 22 V CMC 0,029 % 100 kHz 至 300 kHz 15 V 至 22 V CMC 0,061 % 300 kHz 至 500 kHz 15 V 至 22 V CMC 0,18 % 500 kHz 至 1 MHz 15 V 至 22 V CMC 0,34 % 10 Hz 至 20 Hz 22 V 至 30 V CMC 0,087 % 20 Hz 至 40 Hz 22 V 至 30 V CMC 0,028 % 40 Hz 至 20 kHz 22 V 至 30 V CMC 0,013 % 20 kHz 至 50 kHz 22 V 至 30 V CMC 0,039 % 50 kHz 至 100 kHz 22 V 至 30 V CMC 0,087 % 10 Hz 至 20 Hz 30 V 至 50 V CMC 0,078 % 20 Hz 至 40 Hz 30 V 至 50 V CMC 0,025 % 40 Hz 至 20 kHz 30 V 至 50 V CMC 0,012 % 20 kHz 至 50 kHz 30 V 至 50 V CMC 0,034 % 50 kHz 至 100 kHz 30 V 至 50 V CMC 0,078 % 10 Hz 至 20 Hz 50 V 至 100 V CMC 0,067 % 20 Hz 至 40 Hz 50 V 至 100 V CMC 0,022 % 40 Hz 至 20 kHz 50 V 至 100 V CMC 0,011 % 20 kHz 至 50 kHz 50 V 至 100 V CMC 0,030 % 50 kHz 至 100 kHz 50 V 至 100 V CMC 0,067 % 10 Hz 至 20 Hz 100 V 至 150 V CMC 0,059 % 20 Hz 至 40 Hz 100 V 至 150 V CMC 0,019 % 40 Hz 至 20 kHz 100 V 至 150 V CMC 0,010 % 20 kHz 至 50 kHz 100 V 至 150 V CMC 0,026 % 50 kHz 至 100 kHz 100 V 至 150 V CMC 0,059 % 10 Hz 至 20 Hz 150 V 至 220 V CMC 0,057 % 20 Hz 至 40 Hz 150 V 至 220 V CMC 0,019 % 40 Hz 至 20 kHz 150 V 至 220 V CMC 0,011 % 20 kHz 至 50 kHz 150 V 至 220 V CMC 0,027 % 50 kHz 至 100 kHz 150 V 至 220 V CMC 0,065 % 10 Hz 至 50 Hz 220 V 至 300 V CMC 0,030 % 50 Hz 至 1 kHz 220 V 至 300 V CMC 0,012 % 1 kHz 至 10 kHz 220 V 至 300 V CMC 0,026 % 10 kHz 至 30 kHz 220 V 至 300 V CMC 0,042 % 10 Hz 至 50 Hz 300 V 至 400 V CMC 0,030 % 50 Hz 至 1 kHz 300 V 至 400 V CMC 0,012 % 1 kHz 至 10 kHz 300 V 至 400 V CMC 0,026 % 10 kHz 至 30 kHz 300 V 至 400 V CMC 0,042 % 10 Hz 至 50 Hz 400 V 至 500 V CMC 0,028 % 50 Hz 至 1 kHz 400 V 至 500 V CMC 0,012 % 1 kHz 至 10 kHz 400 V 至 500 V CMC 0,025 % 10 kHz 至 30 kHz 400 V 至 500 V CMC 0,045 % 10 Hz 至 50 Hz 500 V 至 600 V CMC 0,027 % 50 Hz 至 1 kHz 500 V 至 600 V CMC 0,011 % 1 kHz 至 10 kHz 500 V 至 600 V CMC 0,023 % 10 kHz 至 30 kHz 500 V 至 600 V CMC 0,053 % 10 Hz 至 50 Hz 600 V 至 700 V CMC 0,028 % 50 Hz 至 1 kHz 600 V 至 700 V CMC 0,012 % 1 kHz 至 10 kHz 600 V 至 700 V CMC 0,025 % 10 kHz 至 30 kHz 600 V 至 700 V CMC 0,068 % 10 Hz 至 50 Hz 700 V 至 800 V CMC 0,030 % 50 Hz 至 1 kHz 700 V 至 800 V CMC 0,011 % 1 kHz 至 10 kHz 700 V 至 800 V CMC 0,028 % 10 kHz 至 30 kHz 700 V 至 800 V CMC 0,089 % 10 Hz 至 50 Hz 800 V 至 1050 V CMC 0,040 % 50 Hz 至 1 kHz 800 V 至 1050 V CMC 0,010 % 1 kHz 至 10 kHz 800 V 至 1050 V CMC 0,038 % 10 kHz 至 30 kHz 800 V 至 1050 V CMC 0,17 % TP2, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a53dce6141db599002de2e5","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / Źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / Zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 nA do 1 µA","cmc":"0,42 nA"},{"name":"","range":"od 1 µA do 5 µA","cmc":"0,47 nA"},{"name":"","range":"od 5 µA do 10 µA","cmc":"0,53 nA"},{"name":"","range":"od 10 µA do 15 µA","cmc":"0,59 nA"},{"name":"","range":"od 15 µA do 20 µA","cmc":"0,65 nA"},{"name":"","range":"od 20 µA do 30 µA","cmc":"0,0033 %"},{"name":"","range":"od 30 µA do 50 µA","cmc":"0,0026 %"},{"name":"","range":"od 50 µA do 60 µA","cmc":"0,0021 %"},{"name":"","range":"od 60 µA do 90 µA","cmc":"0,0019 %"},{"name":"","range":"od 90 µA do 140 µA","cmc":"0,0017 %"},{"name":"","range":"od 140 µA do 200 µA","cmc":"0,0015 %"},{"name":"","range":"od 200 µA do 250 µA","cmc":"0,0033 %"},{"name":"","range":"od 250 µA do 300 µA","cmc":"0,0029 %"},{"name":"","range":"od 300 µA do 400 µA","cmc":"0,0026 %"},{"name":"","range":"od 400 µA do 500 µA","cmc":"0,0023 %"},{"name":"","range":"od 500 µA do 600 µA","cmc":"0,0021 %"},{"name":"","range":"od 600 µA do 900 µA","cmc":"0,0019 %"},{"name":"","range":"od 900 µA do 1,1 mA","cmc":"0,0017 %"},{"name":"","range":"od 1,1 mA do 2 mA","cmc":"0,0016 %"},{"name":"","range":"od 2 mA do 2,5 mA","cmc":"0,0034 %"},{"name":"","range":"od 2,5 mA do 3 mA","cmc":"0,0030 %"},{"name":"","range":"od 3 mA do 4 mA","cmc":"0,0027 %"},{"name":"","range":"od 4 mA do 5 mA","cmc":"0,0024 %"},{"name":"","range":"od 5 mA do 6 mA","cmc":"0,0022 %"},{"name":"","range":"od 6 mA do 9 mA","cmc":"0,0020 %"},{"name":"","range":"od 9 mA do 11 mA","cmc":"0,0018 %"},{"name":"","range":"od 11 mA do 20 mA","cmc":"0,0017 %"},{"name":"","range":"od 20 mA do 25 mA","cmc":"0,0077 %"},{"name":"","range":"od 25 mA do 30 mA","cmc":"0,0069 %"},{"name":"","range":"od 30 mA do 40 mA","cmc":"0,0064 %"},{"name":"","range":"od 40 mA do 50 mA","cmc":"0,0057 %"},{"name":"","range":"od 50 mA do 60 mA","cmc":"0,0053 %"},{"name":"","range":"od 60 mA do 70 mA","cmc":"0,0050 %"},{"name":"","range":"od 70 mA do 90 mA","cmc":"0,0048 %"},{"name":"","range":"od 90 mA do 100 mA","cmc":"0,0046 %"},{"name":"","range":"od 100 mA do 130 mA","cmc":"0,0045 %"},{"name":"","range":"od 130 mA do 190 mA","cmc":"0,0043 %"},{"name":"","range":"od 190 mA do 200 mA","cmc":"0,0041 %"},{"name":"","range":"od 200 mA do 250 mA","cmc":"0,026 %"},{"name":"","range":"od 250 mA do 300 mA","cmc":"0,024 %"},{"name":"","range":"od 300 mA do 400 mA","cmc":"0,023 %"},{"name":"","range":"od 400 mA do 600 mA","cmc":"0,022 %"},{"name":"","range":"od 600 mA do 900 mA","cmc":"0,020 %"},{"name":"","range":"od 900 mA do 1,7 A","cmc":"0,019 %"},{"name":"","range":"od 1,7 A do 2 A","cmc":"0,018 %"},{"name":"","range":"od 2 A do 60 A","cmc":"0,020 %"},{"name":"","range":"od 60 A do 200 A","cmc":"0,040 %"},{"name":"","range":"od 200 A do 300 A","cmc":"0,2 %"},{"name":"","range":"od 300 A do 600 A","cmc":"0,3 %"}],"parameters_en":[{"name":"","range":"0 nA to 1 µA","cmc":"0,42 nA"},{"name":"","range":"1 µA to 5 µA","cmc":"0,47 nA"},{"name":"","range":"5 µA to 10 µA","cmc":"0,53 nA"},{"name":"","range":"10 µA to 15 µA","cmc":"0,59 nA"},{"name":"","range":"15 µA to 20 µA","cmc":"0,65 nA"},{"name":"","range":"20 µA to 30 µA","cmc":"0,0033 %"},{"name":"","range":"30 µA to 50 µA","cmc":"0,0026 %"},{"name":"","range":"50 µA to 60 µA","cmc":"0,0021 %"},{"name":"","range":"60 µA to 90 µA","cmc":"0,0019 %"},{"name":"","range":"90 µA to 140 µA","cmc":"0,0017 %"},{"name":"","range":"140 µA to 200 µA","cmc":"0,0015 %"},{"name":"","range":"200 µA to 250 µA","cmc":"0,0033 %"},{"name":"","range":"250 µA to 300 µA","cmc":"0,0029 %"},{"name":"","range":"300 µA to 400 µA","cmc":"0,0026 %"},{"name":"","range":"400 µA to 500 µA","cmc":"0,0023 %"},{"name":"","range":"500 µA to 600 µA","cmc":"0,0021 %"},{"name":"","range":"600 µA to 900 µA","cmc":"0,0019 %"},{"name":"","range":"900 µA to 1,1 mA","cmc":"0,0017 %"},{"name":"","range":"1,1 mA to 2 mA","cmc":"0,0016 %"},{"name":"","range":"2 mA to 2,5 mA","cmc":"0,0034 %"},{"name":"","range":"2,5 mA to 3 mA","cmc":"0,0030 %"},{"name":"","range":"3 mA to 4 mA","cmc":"0,0027 %"},{"name":"","range":"4 mA to 5 mA","cmc":"0,0024 %"},{"name":"","range":"5 mA to 6 mA","cmc":"0,0022 %"},{"name":"","range":"6 mA to 9 mA","cmc":"0,0020 %"},{"name":"","range":"9 mA to 11 mA","cmc":"0,0018 %"},{"name":"","range":"11 mA to 20 mA","cmc":"0,0017 %"},{"name":"","range":"20 mA to 25 mA","cmc":"0,0077 %"},{"name":"","range":"25 mA to 30 mA","cmc":"0,0069 %"},{"name":"","range":"30 mA to 40 mA","cmc":"0,0064 %"},{"name":"","range":"40 mA to 50 mA","cmc":"0,0057 %"},{"name":"","range":"50 mA to 60 mA","cmc":"0,0053 %"},{"name":"","range":"60 mA to 70 mA","cmc":"0,0050 %"},{"name":"","range":"70 mA to 90 mA","cmc":"0,0048 %"},{"name":"","range":"90 mA to 100 mA","cmc":"0,0046 %"},{"name":"","range":"100 mA to 130 mA","cmc":"0,0045 %"},{"name":"","range":"130 mA to 190 mA","cmc":"0,0043 %"},{"name":"","range":"190 mA to 200 mA","cmc":"0,0041 %"},{"name":"","range":"200 mA to 250 mA","cmc":"0,026 %"},{"name":"","range":"250 mA to 300 mA","cmc":"0,024 %"},{"name":"","range":"300 mA to 400 mA","cmc":"0,023 %"},{"name":"","range":"400 mA to 600 mA","cmc":"0,022 %"},{"name":"","range":"600 mA to 900 mA","cmc":"0,020 %"},{"name":"","range":"900 mA to 1,7 A","cmc":"0,019 %"},{"name":"","range":"1,7 A to 2 A","cmc":"0,018 %"},{"name":"","range":"2 A to 60 A","cmc":"0,020 %"},{"name":"","range":"60 A to 200 A","cmc":"0,040 %"},{"name":"","range":"200 A to 300 A","cmc":"0,2 %"},{"name":"","range":"300 A to 600 A","cmc":"0,3 %"}],"parameters_zh":[{"name":"","range":"0 nA 至 1 µA","cmc":"0,42 nA"},{"name":"","range":"1 µA 至 5 µA","cmc":"0,47 nA"},{"name":"","range":"5 µA 至 10 µA","cmc":"0,53 nA"},{"name":"","range":"10 µA 至 15 µA","cmc":"0,59 nA"},{"name":"","range":"15 µA 至 20 µA","cmc":"0,65 nA"},{"name":"","range":"20 µA 至 30 µA","cmc":"0,0033 %"},{"name":"","range":"30 µA 至 50 µA","cmc":"0,0026 %"},{"name":"","range":"50 µA 至 60 µA","cmc":"0,0021 %"},{"name":"","range":"60 µA 至 90 µA","cmc":"0,0019 %"},{"name":"","range":"90 µA 至 140 µA","cmc":"0,0017 %"},{"name":"","range":"140 µA 至 200 µA","cmc":"0,0015 %"},{"name":"","range":"200 µA 至 250 µA","cmc":"0,0033 %"},{"name":"","range":"250 µA 至 300 µA","cmc":"0,0029 %"},{"name":"","range":"300 µA 至 400 µA","cmc":"0,0026 %"},{"name":"","range":"400 µA 至 500 µA","cmc":"0,0023 %"},{"name":"","range":"500 µA 至 600 µA","cmc":"0,0021 %"},{"name":"","range":"600 µA 至 900 µA","cmc":"0,0019 %"},{"name":"","range":"900 µA 至 1,1 mA","cmc":"0,0017 %"},{"name":"","range":"1,1 mA 至 2 mA","cmc":"0,0016 %"},{"name":"","range":"2 mA 至 2,5 mA","cmc":"0,0034 %"},{"name":"","range":"2,5 mA 至 3 mA","cmc":"0,0030 %"},{"name":"","range":"3 mA 至 4 mA","cmc":"0,0027 %"},{"name":"","range":"4 mA 至 5 mA","cmc":"0,0024 %"},{"name":"","range":"5 mA 至 6 mA","cmc":"0,0022 %"},{"name":"","range":"6 mA 至 9 mA","cmc":"0,0020 %"},{"name":"","range":"9 mA 至 11 mA","cmc":"0,0018 %"},{"name":"","range":"11 mA 至 20 mA","cmc":"0,0017 %"},{"name":"","range":"20 mA 至 25 mA","cmc":"0,0077 %"},{"name":"","range":"25 mA 至 30 mA","cmc":"0,0069 %"},{"name":"","range":"30 mA 至 40 mA","cmc":"0,0064 %"},{"name":"","range":"40 mA 至 50 mA","cmc":"0,0057 %"},{"name":"","range":"50 mA 至 60 mA","cmc":"0,0053 %"},{"name":"","range":"60 mA 至 70 mA","cmc":"0,0050 %"},{"name":"","range":"70 mA 至 90 mA","cmc":"0,0048 %"},{"name":"","range":"90 mA 至 100 mA","cmc":"0,0046 %"},{"name":"","range":"100 mA 至 130 mA","cmc":"0,0045 %"},{"name":"","range":"130 mA 至 190 mA","cmc":"0,0043 %"},{"name":"","range":"190 mA 至 200 mA","cmc":"0,0041 %"},{"name":"","range":"200 mA 至 250 mA","cmc":"0,026 %"},{"name":"","range":"250 mA 至 300 mA","cmc":"0,024 %"},{"name":"","range":"300 mA 至 400 mA","cmc":"0,023 %"},{"name":"","range":"400 mA 至 600 mA","cmc":"0,022 %"},{"name":"","range":"600 mA 至 900 mA","cmc":"0,020 %"},{"name":"","range":"900 mA 至 1,7 A","cmc":"0,019 %"},{"name":"","range":"1,7 A 至 2 A","cmc":"0,018 %"},{"name":"","range":"2 A 至 60 A","cmc":"0,020 %"},{"name":"","range":"60 A 至 200 A","cmc":"0,040 %"},{"name":"","range":"200 A 至 300 A","cmc":"0,2 %"},{"name":"","range":"300 A 至 600 A","cmc":"0,3 %"}],"parameters_cs":[{"name":"","range":"0 nA až 1 µA","cmc":"0,42 nA"},{"name":"","range":"1 µA až 5 µA","cmc":"0,47 nA"},{"name":"","range":"5 µA až 10 µA","cmc":"0,53 nA"},{"name":"","range":"10 µA až 15 µA","cmc":"0,59 nA"},{"name":"","range":"15 µA až 20 µA","cmc":"0,65 nA"},{"name":"","range":"20 µA až 30 µA","cmc":"0,0033 %"},{"name":"","range":"30 µA až 50 µA","cmc":"0,0026 %"},{"name":"","range":"50 µA až 60 µA","cmc":"0,0021 %"},{"name":"","range":"60 µA až 90 µA","cmc":"0,0019 %"},{"name":"","range":"90 µA až 140 µA","cmc":"0,0017 %"},{"name":"","range":"140 µA až 200 µA","cmc":"0,0015 %"},{"name":"","range":"200 µA až 250 µA","cmc":"0,0033 %"},{"name":"","range":"250 µA až 300 µA","cmc":"0,0029 %"},{"name":"","range":"300 µA až 400 µA","cmc":"0,0026 %"},{"name":"","range":"400 µA až 500 µA","cmc":"0,0023 %"},{"name":"","range":"500 µA až 600 µA","cmc":"0,0021 %"},{"name":"","range":"600 µA až 900 µA","cmc":"0,0019 %"},{"name":"","range":"900 µA až 1,1 mA","cmc":"0,0017 %"},{"name":"","range":"1,1 mA až 2 mA","cmc":"0,0016 %"},{"name":"","range":"2 mA až 2,5 mA","cmc":"0,0034 %"},{"name":"","range":"2,5 mA až 3 mA","cmc":"0,0030 %"},{"name":"","range":"3 mA až 4 mA","cmc":"0,0027 %"},{"name":"","range":"4 mA až 5 mA","cmc":"0,0024 %"},{"name":"","range":"5 mA až 6 mA","cmc":"0,0022 %"},{"name":"","range":"6 mA až 9 mA","cmc":"0,0020 %"},{"name":"","range":"9 mA až 11 mA","cmc":"0,0018 %"},{"name":"","range":"11 mA až 20 mA","cmc":"0,0017 %"},{"name":"","range":"20 mA až 25 mA","cmc":"0,0077 %"},{"name":"","range":"25 mA až 30 mA","cmc":"0,0069 %"},{"name":"","range":"30 mA až 40 mA","cmc":"0,0064 %"},{"name":"","range":"40 mA až 50 mA","cmc":"0,0057 %"},{"name":"","range":"50 mA až 60 mA","cmc":"0,0053 %"},{"name":"","range":"60 mA až 70 mA","cmc":"0,0050 %"},{"name":"","range":"70 mA až 90 mA","cmc":"0,0048 %"},{"name":"","range":"90 mA až 100 mA","cmc":"0,0046 %"},{"name":"","range":"100 mA až 130 mA","cmc":"0,0045 %"},{"name":"","range":"130 mA až 190 mA","cmc":"0,0043 %"},{"name":"","range":"190 mA až 200 mA","cmc":"0,0041 %"},{"name":"","range":"200 mA až 250 mA","cmc":"0,026 %"},{"name":"","range":"250 mA až 300 mA","cmc":"0,024 %"},{"name":"","range":"300 mA až 400 mA","cmc":"0,023 %"},{"name":"","range":"400 mA až 600 mA","cmc":"0,022 %"},{"name":"","range":"600 mA až 900 mA","cmc":"0,020 %"},{"name":"","range":"900 mA až 1,7 A","cmc":"0,019 %"},{"name":"","range":"1,7 A až 2 A","cmc":"0,018 %"},{"name":"","range":"2 A až 60 A","cmc":"0,020 %"},{"name":"","range":"60 A až 200 A","cmc":"0,040 %"},{"name":"","range":"200 A až 300 A","cmc":"0,2 %"},{"name":"","range":"300 A až 600 A","cmc":"0,3 %"}],"technique":"Pomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego","technique_en":"Direct measurement with a multimeter or indirect measurement with a current shunt","technique_zh":"用万用表直接测量或借助电流分流器间接测量","technique_cs":"Přímé měření multimetrem nebo nepřímé měření pomocí proudového bočníku","techniques":["Pomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego"],"techniques_en":["Direct measurement with a multimeter or indirect measurement with a current shunt"],"techniques_zh":["用万用表直接测量或借助电流分流器间接测量"],"techniques_cs":["Přímé měření multimetrem nebo nepřímé měření pomocí proudového bočníku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 nA do 1 µA CMC 0,42 nA\nod 1 µA do 5 µA CMC 0,47 nA\nod 5 µA do 10 µA CMC 0,53 nA\nod 10 µA do 15 µA CMC 0,59 nA\nod 15 µA do 20 µA CMC 0,65 nA\nod 20 µA do 30 µA CMC 0,0033 %\nod 30 µA do 50 µA CMC 0,0026 %\nod 50 µA do 60 µA CMC 0,0021 %\nod 60 µA do 90 µA CMC 0,0019 %\nod 90 µA do 140 µA CMC 0,0017 %\nod 140 µA do 200 µA CMC 0,0015 %\nod 200 µA do 250 µA CMC 0,0033 %\nod 250 µA do 300 µA CMC 0,0029 %\nod 300 µA do 400 µA CMC 0,0026 %\nod 400 µA do 500 µA CMC 0,0023 %\nod 500 µA do 600 µA CMC 0,0021 %\nod 600 µA do 900 µA CMC 0,0019 %\nod 900 µA do 1,1 mA CMC 0,0017 %\nod 1,1 mA do 2 mA CMC 0,0016 %\nod 2 mA do 2,5 mA CMC 0,0034 %\nod 2,5 mA do 3 mA CMC 0,0030 %\nod 3 mA do 4 mA CMC 0,0027 %\nod 4 mA do 5 mA CMC 0,0024 %\nod 5 mA do 6 mA CMC 0,0022 %\nod 6 mA do 9 mA CMC 0,0020 %\nod 9 mA do 11 mA CMC 0,0018 %\nod 11 mA do 20 mA CMC 0,0017 %\nod 20 mA do 25 mA CMC 0,0077 %\nod 25 mA do 30 mA CMC 0,0069 %\nod 30 mA do 40 mA CMC 0,0064 %\nod 40 mA do 50 mA CMC 0,0057 %\nod 50 mA do 60 mA CMC 0,0053 %\nod 60 mA do 70 mA CMC 0,0050 %\nod 70 mA do 90 mA CMC 0,0048 %\nod 90 mA do 100 mA CMC 0,0046 %\nod 100 mA do 130 mA CMC 0,0045 %\nod 130 mA do 190 mA CMC 0,0043 %\nod 190 mA do 200 mA CMC 0,0041 %\nod 200 mA do 250 mA CMC 0,026 %\nod 250 mA do 300 mA CMC 0,024 %\nod 300 mA do 400 mA CMC 0,023 %\nod 400 mA do 600 mA CMC 0,022 %\nod 600 mA do 900 mA CMC 0,020 %\nod 900 mA do 1,7 A CMC 0,019 %\nod 1,7 A do 2 A CMC 0,018 %\nod 2 A do 60 A CMC 0,020 %\nod 60 A do 200 A CMC 0,040 %\nod 200 A do 300 A CMC 0,2 %\nod 300 A do 600 A CMC 0,3 %\nPomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego","reference":"TP3, TP21","norm_bases":["TP3","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego od 0 nA do 1 µA CMC 0,42 nA od 1 µA do 5 µA CMC 0,47 nA od 5 µA do 10 µA CMC 0,53 nA od 10 µA do 15 µA CMC 0,59 nA od 15 µA do 20 µA CMC 0,65 nA od 20 µA do 30 µA CMC 0,0033 % od 30 µA do 50 µA CMC 0,0026 % od 50 µA do 60 µA CMC 0,0021 % od 60 µA do 90 µA CMC 0,0019 % od 90 µA do 140 µA CMC 0,0017 % od 140 µA do 200 µA CMC 0,0015 % od 200 µA do 250 µA CMC 0,0033 % od 250 µA do 300 µA CMC 0,0029 % od 300 µA do 400 µA CMC 0,0026 % od 400 µA do 500 µA CMC 0,0023 % od 500 µA do 600 µA CMC 0,0021 % od 600 µA do 900 µA CMC 0,0019 % od 900 µA do 1,1 mA CMC 0,0017 % od 1,1 mA do 2 mA CMC 0,0016 % od 2 mA do 2,5 mA CMC 0,0034 % od 2,5 mA do 3 mA CMC 0,0030 % od 3 mA do 4 mA CMC 0,0027 % od 4 mA do 5 mA CMC 0,0024 % od 5 mA do 6 mA CMC 0,0022 % od 6 mA do 9 mA CMC 0,0020 % od 9 mA do 11 mA CMC 0,0018 % od 11 mA do 20 mA CMC 0,0017 % od 20 mA do 25 mA CMC 0,0077 % od 25 mA do 30 mA CMC 0,0069 % od 30 mA do 40 mA CMC 0,0064 % od 40 mA do 50 mA CMC 0,0057 % od 50 mA do 60 mA CMC 0,0053 % od 60 mA do 70 mA CMC 0,0050 % od 70 mA do 90 mA CMC 0,0048 % od 90 mA do 100 mA CMC 0,0046 % od 100 mA do 130 mA CMC 0,0045 % od 130 mA do 190 mA CMC 0,0043 % od 190 mA do 200 mA CMC 0,0041 % od 200 mA do 250 mA CMC 0,026 % od 250 mA do 300 mA CMC 0,024 % od 300 mA do 400 mA CMC 0,023 % od 400 mA do 600 mA CMC 0,022 % od 600 mA do 900 mA CMC 0,020 % od 900 mA do 1,7 A CMC 0,019 % od 1,7 A do 2 A CMC 0,018 % od 2 A do 60 A CMC 0,020 % od 60 A do 200 A CMC 0,040 % od 200 A do 300 A CMC 0,2 % od 300 A do 600 A CMC 0,3 % Stejnosměrný proud / Zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření multimetrem nebo nepřímé měření pomocí proudového bočníku 0 nA až 1 µA CMC 0,42 nA 1 µA až 5 µA CMC 0,47 nA 5 µA až 10 µA CMC 0,53 nA 10 µA až 15 µA CMC 0,59 nA 15 µA až 20 µA CMC 0,65 nA 20 µA až 30 µA CMC 0,0033 % 30 µA až 50 µA CMC 0,0026 % 50 µA až 60 µA CMC 0,0021 % 60 µA až 90 µA CMC 0,0019 % 90 µA až 140 µA CMC 0,0017 % 140 µA až 200 µA CMC 0,0015 % 200 µA až 250 µA CMC 0,0033 % 250 µA až 300 µA CMC 0,0029 % 300 µA až 400 µA CMC 0,0026 % 400 µA až 500 µA CMC 0,0023 % 500 µA až 600 µA CMC 0,0021 % 600 µA až 900 µA CMC 0,0019 % 900 µA až 1,1 mA CMC 0,0017 % 1,1 mA až 2 mA CMC 0,0016 % 2 mA až 2,5 mA CMC 0,0034 % 2,5 mA až 3 mA CMC 0,0030 % 3 mA až 4 mA CMC 0,0027 % 4 mA až 5 mA CMC 0,0024 % 5 mA až 6 mA CMC 0,0022 % 6 mA až 9 mA CMC 0,0020 % 9 mA až 11 mA CMC 0,0018 % 11 mA až 20 mA CMC 0,0017 % 20 mA až 25 mA CMC 0,0077 % 25 mA až 30 mA CMC 0,0069 % 30 mA až 40 mA CMC 0,0064 % 40 mA až 50 mA CMC 0,0057 % 50 mA až 60 mA CMC 0,0053 % 60 mA až 70 mA CMC 0,0050 % 70 mA až 90 mA CMC 0,0048 % 90 mA až 100 mA CMC 0,0046 % 100 mA až 130 mA CMC 0,0045 % 130 mA až 190 mA CMC 0,0043 % 190 mA až 200 mA CMC 0,0041 % 200 mA až 250 mA CMC 0,026 % 250 mA až 300 mA CMC 0,024 % 300 mA až 400 mA CMC 0,023 % 400 mA až 600 mA CMC 0,022 % 600 mA až 900 mA CMC 0,020 % 900 mA až 1,7 A CMC 0,019 % 1,7 A až 2 A CMC 0,018 % 2 A až 60 A CMC 0,020 % 60 A až 200 A CMC 0,040 % 200 A až 300 A CMC 0,2 % 300 A až 600 A CMC 0,3 % TP3, TP21 Prad staly / Zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem lub pomiar posredni za pomoca bocznika pradowego od 0 nA do 1 µA CMC 0,42 nA od 1 µA do 5 µA CMC 0,47 nA od 5 µA do 10 µA CMC 0,53 nA od 10 µA do 15 µA CMC 0,59 nA od 15 µA do 20 µA CMC 0,65 nA od 20 µA do 30 µA CMC 0,0033 % od 30 µA do 50 µA CMC 0,0026 % od 50 µA do 60 µA CMC 0,0021 % od 60 µA do 90 µA CMC 0,0019 % od 90 µA do 140 µA CMC 0,0017 % od 140 µA do 200 µA CMC 0,0015 % od 200 µA do 250 µA CMC 0,0033 % od 250 µA do 300 µA CMC 0,0029 % od 300 µA do 400 µA CMC 0,0026 % od 400 µA do 500 µA CMC 0,0023 % od 500 µA do 600 µA CMC 0,0021 % od 600 µA do 900 µA CMC 0,0019 % od 900 µA do 1,1 mA CMC 0,0017 % od 1,1 mA do 2 mA CMC 0,0016 % od 2 mA do 2,5 mA CMC 0,0034 % od 2,5 mA do 3 mA CMC 0,0030 % od 3 mA do 4 mA CMC 0,0027 % od 4 mA do 5 mA CMC 0,0024 % od 5 mA do 6 mA CMC 0,0022 % od 6 mA do 9 mA CMC 0,0020 % od 9 mA do 11 mA CMC 0,0018 % od 11 mA do 20 mA CMC 0,0017 % od 20 mA do 25 mA CMC 0,0077 % od 25 mA do 30 mA CMC 0,0069 % od 30 mA do 40 mA CMC 0,0064 % od 40 mA do 50 mA CMC 0,0057 % od 50 mA do 60 mA CMC 0,0053 % od 60 mA do 70 mA CMC 0,0050 % od 70 mA do 90 mA CMC 0,0048 % od 90 mA do 100 mA CMC 0,0046 % od 100 mA do 130 mA CMC 0,0045 % od 130 mA do 190 mA CMC 0,0043 % od 190 mA do 200 mA CMC 0,0041 % od 200 mA do 250 mA CMC 0,026 % od 250 mA do 300 mA CMC 0,024 % od 300 mA do 400 mA CMC 0,023 % od 400 mA do 600 mA CMC 0,022 % od 600 mA do 900 mA CMC 0,020 % od 900 mA do 1,7 A CMC 0,019 % od 1,7 A do 2 A CMC 0,018 % od 2 A do 60 A CMC 0,020 % od 60 A do 200 A CMC 0,040 % od 200 A do 300 A CMC 0,2 % od 300 A do 600 A CMC 0,3 % Stejnosmerny proud / Zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem nebo neprime mereni pomoci proudoveho bocniku 0 nA az 1 µA CMC 0,42 nA 1 µA az 5 µA CMC 0,47 nA 5 µA az 10 µA CMC 0,53 nA 10 µA az 15 µA CMC 0,59 nA 15 µA az 20 µA CMC 0,65 nA 20 µA az 30 µA CMC 0,0033 % 30 µA az 50 µA CMC 0,0026 % 50 µA az 60 µA CMC 0,0021 % 60 µA az 90 µA CMC 0,0019 % 90 µA az 140 µA CMC 0,0017 % 140 µA az 200 µA CMC 0,0015 % 200 µA az 250 µA CMC 0,0033 % 250 µA az 300 µA CMC 0,0029 % 300 µA az 400 µA CMC 0,0026 % 400 µA az 500 µA CMC 0,0023 % 500 µA az 600 µA CMC 0,0021 % 600 µA az 900 µA CMC 0,0019 % 900 µA az 1,1 mA CMC 0,0017 % 1,1 mA az 2 mA CMC 0,0016 % 2 mA az 2,5 mA CMC 0,0034 % 2,5 mA az 3 mA CMC 0,0030 % 3 mA az 4 mA CMC 0,0027 % 4 mA az 5 mA CMC 0,0024 % 5 mA az 6 mA CMC 0,0022 % 6 mA az 9 mA CMC 0,0020 % 9 mA az 11 mA CMC 0,0018 % 11 mA az 20 mA CMC 0,0017 % 20 mA az 25 mA CMC 0,0077 % 25 mA az 30 mA CMC 0,0069 % 30 mA az 40 mA CMC 0,0064 % 40 mA az 50 mA CMC 0,0057 % 50 mA az 60 mA CMC 0,0053 % 60 mA az 70 mA CMC 0,0050 % 70 mA az 90 mA CMC 0,0048 % 90 mA az 100 mA CMC 0,0046 % 100 mA az 130 mA CMC 0,0045 % 130 mA az 190 mA CMC 0,0043 % 190 mA az 200 mA CMC 0,0041 % 200 mA az 250 mA CMC 0,026 % 250 mA az 300 mA CMC 0,024 % 300 mA az 400 mA CMC 0,023 % 400 mA az 600 mA CMC 0,022 % 600 mA az 900 mA CMC 0,020 % 900 mA az 1,7 A CMC 0,019 % 1,7 A az 2 A CMC 0,018 % 2 A az 60 A CMC 0,020 % 60 A az 200 A CMC 0,040 % 200 A az 300 A CMC 0,2 % 300 A az 600 A CMC 0,3 % TP3, TP21","search_en":"DC current / DC current sources Calibration – electrical quantities Direct measurement with a multimeter or indirect measurement with a current shunt 0 nA to 1 µA CMC 0,42 nA 1 µA to 5 µA CMC 0,47 nA 5 µA to 10 µA CMC 0,53 nA 10 µA to 15 µA CMC 0,59 nA 15 µA to 20 µA CMC 0,65 nA 20 µA to 30 µA CMC 0,0033 % 30 µA to 50 µA CMC 0,0026 % 50 µA to 60 µA CMC 0,0021 % 60 µA to 90 µA CMC 0,0019 % 90 µA to 140 µA CMC 0,0017 % 140 µA to 200 µA CMC 0,0015 % 200 µA to 250 µA CMC 0,0033 % 250 µA to 300 µA CMC 0,0029 % 300 µA to 400 µA CMC 0,0026 % 400 µA to 500 µA CMC 0,0023 % 500 µA to 600 µA CMC 0,0021 % 600 µA to 900 µA CMC 0,0019 % 900 µA to 1,1 mA CMC 0,0017 % 1,1 mA to 2 mA CMC 0,0016 % 2 mA to 2,5 mA CMC 0,0034 % 2,5 mA to 3 mA CMC 0,0030 % 3 mA to 4 mA CMC 0,0027 % 4 mA to 5 mA CMC 0,0024 % 5 mA to 6 mA CMC 0,0022 % 6 mA to 9 mA CMC 0,0020 % 9 mA to 11 mA CMC 0,0018 % 11 mA to 20 mA CMC 0,0017 % 20 mA to 25 mA CMC 0,0077 % 25 mA to 30 mA CMC 0,0069 % 30 mA to 40 mA CMC 0,0064 % 40 mA to 50 mA CMC 0,0057 % 50 mA to 60 mA CMC 0,0053 % 60 mA to 70 mA CMC 0,0050 % 70 mA to 90 mA CMC 0,0048 % 90 mA to 100 mA CMC 0,0046 % 100 mA to 130 mA CMC 0,0045 % 130 mA to 190 mA CMC 0,0043 % 190 mA to 200 mA CMC 0,0041 % 200 mA to 250 mA CMC 0,026 % 250 mA to 300 mA CMC 0,024 % 300 mA to 400 mA CMC 0,023 % 400 mA to 600 mA CMC 0,022 % 600 mA to 900 mA CMC 0,020 % 900 mA to 1,7 A CMC 0,019 % 1,7 A to 2 A CMC 0,018 % 2 A to 60 A CMC 0,020 % 60 A to 200 A CMC 0,040 % 200 A to 300 A CMC 0,2 % 300 A to 600 A CMC 0,3 % TP3, TP21","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用万用表直接测量或借助电流分流器间接测量 0 nA 至 1 µA CMC 0,42 nA 1 µA 至 5 µA CMC 0,47 nA 5 µA 至 10 µA CMC 0,53 nA 10 µA 至 15 µA CMC 0,59 nA 15 µA 至 20 µA CMC 0,65 nA 20 µA 至 30 µA CMC 0,0033 % 30 µA 至 50 µA CMC 0,0026 % 50 µA 至 60 µA CMC 0,0021 % 60 µA 至 90 µA CMC 0,0019 % 90 µA 至 140 µA CMC 0,0017 % 140 µA 至 200 µA CMC 0,0015 % 200 µA 至 250 µA CMC 0,0033 % 250 µA 至 300 µA CMC 0,0029 % 300 µA 至 400 µA CMC 0,0026 % 400 µA 至 500 µA CMC 0,0023 % 500 µA 至 600 µA CMC 0,0021 % 600 µA 至 900 µA CMC 0,0019 % 900 µA 至 1,1 mA CMC 0,0017 % 1,1 mA 至 2 mA CMC 0,0016 % 2 mA 至 2,5 mA CMC 0,0034 % 2,5 mA 至 3 mA CMC 0,0030 % 3 mA 至 4 mA CMC 0,0027 % 4 mA 至 5 mA CMC 0,0024 % 5 mA 至 6 mA CMC 0,0022 % 6 mA 至 9 mA CMC 0,0020 % 9 mA 至 11 mA CMC 0,0018 % 11 mA 至 20 mA CMC 0,0017 % 20 mA 至 25 mA CMC 0,0077 % 25 mA 至 30 mA CMC 0,0069 % 30 mA 至 40 mA CMC 0,0064 % 40 mA 至 50 mA CMC 0,0057 % 50 mA 至 60 mA CMC 0,0053 % 60 mA 至 70 mA CMC 0,0050 % 70 mA 至 90 mA CMC 0,0048 % 90 mA 至 100 mA CMC 0,0046 % 100 mA 至 130 mA CMC 0,0045 % 130 mA 至 190 mA CMC 0,0043 % 190 mA 至 200 mA CMC 0,0041 % 200 mA 至 250 mA CMC 0,026 % 250 mA 至 300 mA CMC 0,024 % 300 mA 至 400 mA CMC 0,023 % 400 mA 至 600 mA CMC 0,022 % 600 mA 至 900 mA CMC 0,020 % 900 mA 至 1,7 A CMC 0,019 % 1,7 A 至 2 A CMC 0,018 % 2 A 至 60 A CMC 0,020 % 60 A 至 200 A CMC 0,040 % 200 A 至 300 A CMC 0,2 % 300 A 至 600 A CMC 0,3 % TP3, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"409f91c4b51771a49dafe7b2","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / Mierniki prądu stałego","test_object_en":"DC current / DC current meters","test_object_zh":"直流电流 / 直流电流测量仪器","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 20 µA","cmc":"10 nA"},{"name":"","range":"od 20 µA do 30 µA","cmc":"0,046 %"},{"name":"","range":"od 30 µA do 40 µA","cmc":"0,032 %"},{"name":"","range":"od 40 µA do 50 µA","cmc":"0,026 %"},{"name":"","range":"od 50 µA do 60 µA","cmc":"0,022 %"},{"name":"","range":"od 60 µA do 70 µA","cmc":"0,019 %"},{"name":"","range":"od 70 µA do 95 µA","cmc":"0,017 %"},{"name":"","range":"od 95 µA do 120 µA","cmc":"0,014 %"},{"name":"","range":"od 120 µA do 170 µA","cmc":"0,012 %"},{"name":"","range":"od 170 µA do 200 µA","cmc":"0,0099 %"},{"name":"","range":"od 200 µA do 220 µA","cmc":"0,0092 %"},{"name":"","range":"od 220 µA do 300 µA","cmc":"0,0088 %"},{"name":"","range":"od 300 µA do 400 µA","cmc":"0,0078 %"},{"name":"","range":"od 400 µA do 500 µA","cmc":"0,0071 %"},{"name":"","range":"od 500 µA do 600 µA","cmc":"0,0067 %"},{"name":"","range":"od 600 µA do 700 µA","cmc":"0,0065 %"},{"name":"","range":"od 700 µA do 800 µA","cmc":"0,0063 %"},{"name":"","range":"od 800 µA do 1 mA","cmc":"0,0061 %"},{"name":"","range":"od 1 mA do 1,3 mA","cmc":"0,0059 %"},{"name":"","range":"od 1,3 mA do 1,9 mA","cmc":"0,0057 %"},{"name":"","range":"od 1,9 mA do 2,2 mA","cmc":"0,0055 %"},{"name":"","range":"od 2,2 mA do 3 mA","cmc":"0,0088 %"},{"name":"","range":"od 3 mA do 4 mA","cmc":"0,0078 %"},{"name":"","range":"od 4 mA do 5 mA","cmc":"0,0071 %"},{"name":"","range":"od 5 mA do 6 mA","cmc":"0,0067 %"},{"name":"","range":"od 6 mA do 7 mA","cmc":"0,0065 %"},{"name":"","range":"od 7 mA do 8 mA","cmc":"0,0063 %"},{"name":"","range":"od 8 mA do 10 mA","cmc":"0,0061 %"},{"name":"","range":"od 10 mA do 13 mA","cmc":"0,0059 %"},{"name":"","range":"od 13 mA do 19 mA","cmc":"0,0057 %"},{"name":"","range":"od 19 mA do 22 mA","cmc":"0,0055 %"},{"name":"","range":"od 22 mA do 30 mA","cmc":"0,0098 %"},{"name":"","range":"od 30 mA do 40 mA","cmc":"0,0088 %"},{"name":"","range":"od 40 mA do 50 mA","cmc":"0,0082 %"},{"name":"","range":"od 50 mA do 60 mA","cmc":"0,0077 %"},{"name":"","range":"od 60 mA do 70 mA","cmc":"0,0075 %"},{"name":"","range":"od 70 mA do 80 mA","cmc":"0,0073 %"},{"name":"","range":"od 80 mA do 180 mA","cmc":"0,0072 %"},{"name":"","range":"od 180 mA do 220 mA","cmc":"0,0075 %"},{"name":"","range":"od 220 mA do 300 mA","cmc":"0,020 %"},{"name":"","range":"od 300 mA do 400 mA","cmc":"0,017 %"},{"name":"","range":"od 400 mA do 600 mA","cmc":"0,015 %"},{"name":"","range":"od 600 mA do 900 mA","cmc":"0,013 %"},{"name":"","range":"od 900 mA do 1 A","cmc":"0,011 %"},{"name":"","range":"od 1 A do 1,4 A","cmc":"0,012 %"},{"name":"","range":"od 1,4 A do 1,8 A","cmc":"0,013 %"},{"name":"","range":"od 1,8 A do 2 A","cmc":"0,014 %"},{"name":"","range":"od 2 A do 2,2 A","cmc":"0,015 %"},{"name":"","range":"od 2,2 A do 3 A","cmc":"0,044 %"},{"name":"","range":"od 3 A do 4 A","cmc":"0,041 %"},{"name":"","range":"od 4 A do 5 A","cmc":"0,038 %"},{"name":"","range":"od 5 A do 6 A","cmc":"0,037 %"},{"name":"","range":"od 6 A do 7 A","cmc":"0,036 %"},{"name":"","range":"od 7 A do 8 A","cmc":"0,035 %"},{"name":"","range":"od 8 A do 11 A","cmc":"0,034 %"},{"name":"","range":"od 11 A do 20,2 A","cmc":"0,033 %"},{"name":"","range":"od 20,2 A do 23 A","cmc":"0,043 %"},{"name":"","range":"od 23 A do 30 A","cmc":"0,042 %"},{"name":"","range":"od 30 A do 45 A","cmc":"0,083 %"},{"name":"","range":"od 45 A do 60 A","cmc":"0,067 %"},{"name":"","range":"od 60 A do 90 A","cmc":"0,058 %"}],"parameters_en":[{"name":"","range":"0 µA to 20 µA","cmc":"10 nA"},{"name":"","range":"20 µA to 30 µA","cmc":"0,046 %"},{"name":"","range":"30 µA to 40 µA","cmc":"0,032 %"},{"name":"","range":"40 µA to 50 µA","cmc":"0,026 %"},{"name":"","range":"50 µA to 60 µA","cmc":"0,022 %"},{"name":"","range":"60 µA to 70 µA","cmc":"0,019 %"},{"name":"","range":"70 µA to 95 µA","cmc":"0,017 %"},{"name":"","range":"95 µA to 120 µA","cmc":"0,014 %"},{"name":"","range":"120 µA to 170 µA","cmc":"0,012 %"},{"name":"","range":"170 µA to 200 µA","cmc":"0,0099 %"},{"name":"","range":"200 µA to 220 µA","cmc":"0,0092 %"},{"name":"","range":"220 µA to 300 µA","cmc":"0,0088 %"},{"name":"","range":"300 µA to 400 µA","cmc":"0,0078 %"},{"name":"","range":"400 µA to 500 µA","cmc":"0,0071 %"},{"name":"","range":"500 µA to 600 µA","cmc":"0,0067 %"},{"name":"","range":"600 µA to 700 µA","cmc":"0,0065 %"},{"name":"","range":"700 µA to 800 µA","cmc":"0,0063 %"},{"name":"","range":"800 µA to 1 mA","cmc":"0,0061 %"},{"name":"","range":"1 mA to 1,3 mA","cmc":"0,0059 %"},{"name":"","range":"1,3 mA to 1,9 mA","cmc":"0,0057 %"},{"name":"","range":"1,9 mA to 2,2 mA","cmc":"0,0055 %"},{"name":"","range":"2,2 mA to 3 mA","cmc":"0,0088 %"},{"name":"","range":"3 mA to 4 mA","cmc":"0,0078 %"},{"name":"","range":"4 mA to 5 mA","cmc":"0,0071 %"},{"name":"","range":"5 mA to 6 mA","cmc":"0,0067 %"},{"name":"","range":"6 mA to 7 mA","cmc":"0,0065 %"},{"name":"","range":"7 mA to 8 mA","cmc":"0,0063 %"},{"name":"","range":"8 mA to 10 mA","cmc":"0,0061 %"},{"name":"","range":"10 mA to 13 mA","cmc":"0,0059 %"},{"name":"","range":"13 mA to 19 mA","cmc":"0,0057 %"},{"name":"","range":"19 mA to 22 mA","cmc":"0,0055 %"},{"name":"","range":"22 mA to 30 mA","cmc":"0,0098 %"},{"name":"","range":"30 mA to 40 mA","cmc":"0,0088 %"},{"name":"","range":"40 mA to 50 mA","cmc":"0,0082 %"},{"name":"","range":"50 mA to 60 mA","cmc":"0,0077 %"},{"name":"","range":"60 mA to 70 mA","cmc":"0,0075 %"},{"name":"","range":"70 mA to 80 mA","cmc":"0,0073 %"},{"name":"","range":"80 mA to 180 mA","cmc":"0,0072 %"},{"name":"","range":"180 mA to 220 mA","cmc":"0,0075 %"},{"name":"","range":"220 mA to 300 mA","cmc":"0,020 %"},{"name":"","range":"300 mA to 400 mA","cmc":"0,017 %"},{"name":"","range":"400 mA to 600 mA","cmc":"0,015 %"},{"name":"","range":"600 mA to 900 mA","cmc":"0,013 %"},{"name":"","range":"900 mA to 1 A","cmc":"0,011 %"},{"name":"","range":"1 A to 1,4 A","cmc":"0,012 %"},{"name":"","range":"1,4 A to 1,8 A","cmc":"0,013 %"},{"name":"","range":"1,8 A to 2 A","cmc":"0,014 %"},{"name":"","range":"2 A to 2,2 A","cmc":"0,015 %"},{"name":"","range":"2,2 A to 3 A","cmc":"0,044 %"},{"name":"","range":"3 A to 4 A","cmc":"0,041 %"},{"name":"","range":"4 A to 5 A","cmc":"0,038 %"},{"name":"","range":"5 A to 6 A","cmc":"0,037 %"},{"name":"","range":"6 A to 7 A","cmc":"0,036 %"},{"name":"","range":"7 A to 8 A","cmc":"0,035 %"},{"name":"","range":"8 A to 11 A","cmc":"0,034 %"},{"name":"","range":"11 A to 20,2 A","cmc":"0,033 %"},{"name":"","range":"20,2 A to 23 A","cmc":"0,043 %"},{"name":"","range":"23 A to 30 A","cmc":"0,042 %"},{"name":"","range":"30 A to 45 A","cmc":"0,083 %"},{"name":"","range":"45 A to 60 A","cmc":"0,067 %"},{"name":"","range":"60 A to 90 A","cmc":"0,058 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 20 µA","cmc":"10 nA"},{"name":"","range":"20 µA 至 30 µA","cmc":"0,046 %"},{"name":"","range":"30 µA 至 40 µA","cmc":"0,032 %"},{"name":"","range":"40 µA 至 50 µA","cmc":"0,026 %"},{"name":"","range":"50 µA 至 60 µA","cmc":"0,022 %"},{"name":"","range":"60 µA 至 70 µA","cmc":"0,019 %"},{"name":"","range":"70 µA 至 95 µA","cmc":"0,017 %"},{"name":"","range":"95 µA 至 120 µA","cmc":"0,014 %"},{"name":"","range":"120 µA 至 170 µA","cmc":"0,012 %"},{"name":"","range":"170 µA 至 200 µA","cmc":"0,0099 %"},{"name":"","range":"200 µA 至 220 µA","cmc":"0,0092 %"},{"name":"","range":"220 µA 至 300 µA","cmc":"0,0088 %"},{"name":"","range":"300 µA 至 400 µA","cmc":"0,0078 %"},{"name":"","range":"400 µA 至 500 µA","cmc":"0,0071 %"},{"name":"","range":"500 µA 至 600 µA","cmc":"0,0067 %"},{"name":"","range":"600 µA 至 700 µA","cmc":"0,0065 %"},{"name":"","range":"700 µA 至 800 µA","cmc":"0,0063 %"},{"name":"","range":"800 µA 至 1 mA","cmc":"0,0061 %"},{"name":"","range":"1 mA 至 1,3 mA","cmc":"0,0059 %"},{"name":"","range":"1,3 mA 至 1,9 mA","cmc":"0,0057 %"},{"name":"","range":"1,9 mA 至 2,2 mA","cmc":"0,0055 %"},{"name":"","range":"2,2 mA 至 3 mA","cmc":"0,0088 %"},{"name":"","range":"3 mA 至 4 mA","cmc":"0,0078 %"},{"name":"","range":"4 mA 至 5 mA","cmc":"0,0071 %"},{"name":"","range":"5 mA 至 6 mA","cmc":"0,0067 %"},{"name":"","range":"6 mA 至 7 mA","cmc":"0,0065 %"},{"name":"","range":"7 mA 至 8 mA","cmc":"0,0063 %"},{"name":"","range":"8 mA 至 10 mA","cmc":"0,0061 %"},{"name":"","range":"10 mA 至 13 mA","cmc":"0,0059 %"},{"name":"","range":"13 mA 至 19 mA","cmc":"0,0057 %"},{"name":"","range":"19 mA 至 22 mA","cmc":"0,0055 %"},{"name":"","range":"22 mA 至 30 mA","cmc":"0,0098 %"},{"name":"","range":"30 mA 至 40 mA","cmc":"0,0088 %"},{"name":"","range":"40 mA 至 50 mA","cmc":"0,0082 %"},{"name":"","range":"50 mA 至 60 mA","cmc":"0,0077 %"},{"name":"","range":"60 mA 至 70 mA","cmc":"0,0075 %"},{"name":"","range":"70 mA 至 80 mA","cmc":"0,0073 %"},{"name":"","range":"80 mA 至 180 mA","cmc":"0,0072 %"},{"name":"","range":"180 mA 至 220 mA","cmc":"0,0075 %"},{"name":"","range":"220 mA 至 300 mA","cmc":"0,020 %"},{"name":"","range":"300 mA 至 400 mA","cmc":"0,017 %"},{"name":"","range":"400 mA 至 600 mA","cmc":"0,015 %"},{"name":"","range":"600 mA 至 900 mA","cmc":"0,013 %"},{"name":"","range":"900 mA 至 1 A","cmc":"0,011 %"},{"name":"","range":"1 A 至 1,4 A","cmc":"0,012 %"},{"name":"","range":"1,4 A 至 1,8 A","cmc":"0,013 %"},{"name":"","range":"1,8 A 至 2 A","cmc":"0,014 %"},{"name":"","range":"2 A 至 2,2 A","cmc":"0,015 %"},{"name":"","range":"2,2 A 至 3 A","cmc":"0,044 %"},{"name":"","range":"3 A 至 4 A","cmc":"0,041 %"},{"name":"","range":"4 A 至 5 A","cmc":"0,038 %"},{"name":"","range":"5 A 至 6 A","cmc":"0,037 %"},{"name":"","range":"6 A 至 7 A","cmc":"0,036 %"},{"name":"","range":"7 A 至 8 A","cmc":"0,035 %"},{"name":"","range":"8 A 至 11 A","cmc":"0,034 %"},{"name":"","range":"11 A 至 20,2 A","cmc":"0,033 %"},{"name":"","range":"20,2 A 至 23 A","cmc":"0,043 %"},{"name":"","range":"23 A 至 30 A","cmc":"0,042 %"},{"name":"","range":"30 A 至 45 A","cmc":"0,083 %"},{"name":"","range":"45 A 至 60 A","cmc":"0,067 %"},{"name":"","range":"60 A 至 90 A","cmc":"0,058 %"}],"parameters_cs":[{"name":"","range":"0 µA až 20 µA","cmc":"10 nA"},{"name":"","range":"20 µA až 30 µA","cmc":"0,046 %"},{"name":"","range":"30 µA až 40 µA","cmc":"0,032 %"},{"name":"","range":"40 µA až 50 µA","cmc":"0,026 %"},{"name":"","range":"50 µA až 60 µA","cmc":"0,022 %"},{"name":"","range":"60 µA až 70 µA","cmc":"0,019 %"},{"name":"","range":"70 µA až 95 µA","cmc":"0,017 %"},{"name":"","range":"95 µA až 120 µA","cmc":"0,014 %"},{"name":"","range":"120 µA až 170 µA","cmc":"0,012 %"},{"name":"","range":"170 µA až 200 µA","cmc":"0,0099 %"},{"name":"","range":"200 µA až 220 µA","cmc":"0,0092 %"},{"name":"","range":"220 µA až 300 µA","cmc":"0,0088 %"},{"name":"","range":"300 µA až 400 µA","cmc":"0,0078 %"},{"name":"","range":"400 µA až 500 µA","cmc":"0,0071 %"},{"name":"","range":"500 µA až 600 µA","cmc":"0,0067 %"},{"name":"","range":"600 µA až 700 µA","cmc":"0,0065 %"},{"name":"","range":"700 µA až 800 µA","cmc":"0,0063 %"},{"name":"","range":"800 µA až 1 mA","cmc":"0,0061 %"},{"name":"","range":"1 mA až 1,3 mA","cmc":"0,0059 %"},{"name":"","range":"1,3 mA až 1,9 mA","cmc":"0,0057 %"},{"name":"","range":"1,9 mA až 2,2 mA","cmc":"0,0055 %"},{"name":"","range":"2,2 mA až 3 mA","cmc":"0,0088 %"},{"name":"","range":"3 mA až 4 mA","cmc":"0,0078 %"},{"name":"","range":"4 mA až 5 mA","cmc":"0,0071 %"},{"name":"","range":"5 mA až 6 mA","cmc":"0,0067 %"},{"name":"","range":"6 mA až 7 mA","cmc":"0,0065 %"},{"name":"","range":"7 mA až 8 mA","cmc":"0,0063 %"},{"name":"","range":"8 mA až 10 mA","cmc":"0,0061 %"},{"name":"","range":"10 mA až 13 mA","cmc":"0,0059 %"},{"name":"","range":"13 mA až 19 mA","cmc":"0,0057 %"},{"name":"","range":"19 mA až 22 mA","cmc":"0,0055 %"},{"name":"","range":"22 mA až 30 mA","cmc":"0,0098 %"},{"name":"","range":"30 mA až 40 mA","cmc":"0,0088 %"},{"name":"","range":"40 mA až 50 mA","cmc":"0,0082 %"},{"name":"","range":"50 mA až 60 mA","cmc":"0,0077 %"},{"name":"","range":"60 mA až 70 mA","cmc":"0,0075 %"},{"name":"","range":"70 mA až 80 mA","cmc":"0,0073 %"},{"name":"","range":"80 mA až 180 mA","cmc":"0,0072 %"},{"name":"","range":"180 mA až 220 mA","cmc":"0,0075 %"},{"name":"","range":"220 mA až 300 mA","cmc":"0,020 %"},{"name":"","range":"300 mA až 400 mA","cmc":"0,017 %"},{"name":"","range":"400 mA až 600 mA","cmc":"0,015 %"},{"name":"","range":"600 mA až 900 mA","cmc":"0,013 %"},{"name":"","range":"900 mA až 1 A","cmc":"0,011 %"},{"name":"","range":"1 A až 1,4 A","cmc":"0,012 %"},{"name":"","range":"1,4 A až 1,8 A","cmc":"0,013 %"},{"name":"","range":"1,8 A až 2 A","cmc":"0,014 %"},{"name":"","range":"2 A až 2,2 A","cmc":"0,015 %"},{"name":"","range":"2,2 A až 3 A","cmc":"0,044 %"},{"name":"","range":"3 A až 4 A","cmc":"0,041 %"},{"name":"","range":"4 A až 5 A","cmc":"0,038 %"},{"name":"","range":"5 A až 6 A","cmc":"0,037 %"},{"name":"","range":"6 A až 7 A","cmc":"0,036 %"},{"name":"","range":"7 A až 8 A","cmc":"0,035 %"},{"name":"","range":"8 A až 11 A","cmc":"0,034 %"},{"name":"","range":"11 A až 20,2 A","cmc":"0,033 %"},{"name":"","range":"20,2 A až 23 A","cmc":"0,043 %"},{"name":"","range":"23 A až 30 A","cmc":"0,042 %"},{"name":"","range":"30 A až 45 A","cmc":"0,083 %"},{"name":"","range":"45 A až 60 A","cmc":"0,067 %"},{"name":"","range":"60 A až 90 A","cmc":"0,058 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 20 µA CMC 10 nA\nod 20 µA do 30 µA CMC 0,046 %\nod 30 µA do 40 µA CMC 0,032 %\nod 40 µA do 50 µA CMC 0,026 %\nod 50 µA do 60 µA CMC 0,022 %\nod 60 µA do 70 µA CMC 0,019 %\nod 70 µA do 95 µA CMC 0,017 %\nod 95 µA do 120 µA CMC 0,014 %\nod 120 µA do 170 µA CMC 0,012 %\nod 170 µA do 200 µA CMC 0,0099 %\nod 200 µA do 220 µA CMC 0,0092 %\nod 220 µA do 300 µA CMC 0,0088 %\nod 300 µA do 400 µA CMC 0,0078 %\nod 400 µA do 500 µA CMC 0,0071 %\nod 500 µA do 600 µA CMC 0,0067 %\nod 600 µA do 700 µA CMC 0,0065 %\nod 700 µA do 800 µA CMC 0,0063 %\nod 800 µA do 1 mA CMC 0,0061 %\nod 1 mA do 1,3 mA CMC 0,0059 %\nod 1,3 mA do 1,9 mA CMC 0,0057 %\nod 1,9 mA do 2,2 mA CMC 0,0055 %\nod 2,2 mA do 3 mA CMC 0,0088 %\nod 3 mA do 4 mA CMC 0,0078 %\nod 4 mA do 5 mA CMC 0,0071 %\nod 5 mA do 6 mA CMC 0,0067 %\nod 6 mA do 7 mA CMC 0,0065 %\nod 7 mA do 8 mA CMC 0,0063 %\nod 8 mA do 10 mA CMC 0,0061 %\nod 10 mA do 13 mA CMC 0,0059 %\nod 13 mA do 19 mA CMC 0,0057 %\nod 19 mA do 22 mA CMC 0,0055 %\nod 22 mA do 30 mA CMC 0,0098 %\nod 30 mA do 40 mA CMC 0,0088 %\nod 40 mA do 50 mA CMC 0,0082 %\nod 50 mA do 60 mA CMC 0,0077 %\nod 60 mA do 70 mA CMC 0,0075 %\nod 70 mA do 80 mA CMC 0,0073 %\nod 80 mA do 180 mA CMC 0,0072 %\nod 180 mA do 220 mA CMC 0,0075 %\nod 220 mA do 300 mA CMC 0,020 %\nod 300 mA do 400 mA CMC 0,017 %\nod 400 mA do 600 mA CMC 0,015 %\nod 600 mA do 900 mA CMC 0,013 %\nod 900 mA do 1 A CMC 0,011 %\nod 1 A do 1,4 A CMC 0,012 %\nod 1,4 A do 1,8 A CMC 0,013 %\nod 1,8 A do 2 A CMC 0,014 %\nod 2 A do 2,2 A CMC 0,015 %\nod 2,2 A do 3 A CMC 0,044 %\nod 3 A do 4 A CMC 0,041 %\nod 4 A do 5 A CMC 0,038 %\nod 5 A do 6 A CMC 0,037 %\nod 6 A do 7 A CMC 0,036 %\nod 7 A do 8 A CMC 0,035 %\nod 8 A do 11 A CMC 0,034 %\nod 11 A do 20,2 A CMC 0,033 %\nod 20,2 A do 23 A CMC 0,043 %\nod 23 A do 30 A CMC 0,042 %\nod 30 A do 45 A CMC 0,083 %\nod 45 A do 60 A CMC 0,067 %\nod 60 A do 90 A CMC 0,058 %\nBezpośrednie generowanie kalibratorem","reference":"TP3, TP21","norm_bases":["TP3","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Mierniki prądu stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 µA do 20 µA CMC 10 nA od 20 µA do 30 µA CMC 0,046 % od 30 µA do 40 µA CMC 0,032 % od 40 µA do 50 µA CMC 0,026 % od 50 µA do 60 µA CMC 0,022 % od 60 µA do 70 µA CMC 0,019 % od 70 µA do 95 µA CMC 0,017 % od 95 µA do 120 µA CMC 0,014 % od 120 µA do 170 µA CMC 0,012 % od 170 µA do 200 µA CMC 0,0099 % od 200 µA do 220 µA CMC 0,0092 % od 220 µA do 300 µA CMC 0,0088 % od 300 µA do 400 µA CMC 0,0078 % od 400 µA do 500 µA CMC 0,0071 % od 500 µA do 600 µA CMC 0,0067 % od 600 µA do 700 µA CMC 0,0065 % od 700 µA do 800 µA CMC 0,0063 % od 800 µA do 1 mA CMC 0,0061 % od 1 mA do 1,3 mA CMC 0,0059 % od 1,3 mA do 1,9 mA CMC 0,0057 % od 1,9 mA do 2,2 mA CMC 0,0055 % od 2,2 mA do 3 mA CMC 0,0088 % od 3 mA do 4 mA CMC 0,0078 % od 4 mA do 5 mA CMC 0,0071 % od 5 mA do 6 mA CMC 0,0067 % od 6 mA do 7 mA CMC 0,0065 % od 7 mA do 8 mA CMC 0,0063 % od 8 mA do 10 mA CMC 0,0061 % od 10 mA do 13 mA CMC 0,0059 % od 13 mA do 19 mA CMC 0,0057 % od 19 mA do 22 mA CMC 0,0055 % od 22 mA do 30 mA CMC 0,0098 % od 30 mA do 40 mA CMC 0,0088 % od 40 mA do 50 mA CMC 0,0082 % od 50 mA do 60 mA CMC 0,0077 % od 60 mA do 70 mA CMC 0,0075 % od 70 mA do 80 mA CMC 0,0073 % od 80 mA do 180 mA CMC 0,0072 % od 180 mA do 220 mA CMC 0,0075 % od 220 mA do 300 mA CMC 0,020 % od 300 mA do 400 mA CMC 0,017 % od 400 mA do 600 mA CMC 0,015 % od 600 mA do 900 mA CMC 0,013 % od 900 mA do 1 A CMC 0,011 % od 1 A do 1,4 A CMC 0,012 % od 1,4 A do 1,8 A CMC 0,013 % od 1,8 A do 2 A CMC 0,014 % od 2 A do 2,2 A CMC 0,015 % od 2,2 A do 3 A CMC 0,044 % od 3 A do 4 A CMC 0,041 % od 4 A do 5 A CMC 0,038 % od 5 A do 6 A CMC 0,037 % od 6 A do 7 A CMC 0,036 % od 7 A do 8 A CMC 0,035 % od 8 A do 11 A CMC 0,034 % od 11 A do 20,2 A CMC 0,033 % od 20,2 A do 23 A CMC 0,043 % od 23 A do 30 A CMC 0,042 % od 30 A do 45 A CMC 0,083 % od 45 A do 60 A CMC 0,067 % od 60 A do 90 A CMC 0,058 % Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 µA až 20 µA CMC 10 nA 20 µA až 30 µA CMC 0,046 % 30 µA až 40 µA CMC 0,032 % 40 µA až 50 µA CMC 0,026 % 50 µA až 60 µA CMC 0,022 % 60 µA až 70 µA CMC 0,019 % 70 µA až 95 µA CMC 0,017 % 95 µA až 120 µA CMC 0,014 % 120 µA až 170 µA CMC 0,012 % 170 µA až 200 µA CMC 0,0099 % 200 µA až 220 µA CMC 0,0092 % 220 µA až 300 µA CMC 0,0088 % 300 µA až 400 µA CMC 0,0078 % 400 µA až 500 µA CMC 0,0071 % 500 µA až 600 µA CMC 0,0067 % 600 µA až 700 µA CMC 0,0065 % 700 µA až 800 µA CMC 0,0063 % 800 µA až 1 mA CMC 0,0061 % 1 mA až 1,3 mA CMC 0,0059 % 1,3 mA až 1,9 mA CMC 0,0057 % 1,9 mA až 2,2 mA CMC 0,0055 % 2,2 mA až 3 mA CMC 0,0088 % 3 mA až 4 mA CMC 0,0078 % 4 mA až 5 mA CMC 0,0071 % 5 mA až 6 mA CMC 0,0067 % 6 mA až 7 mA CMC 0,0065 % 7 mA až 8 mA CMC 0,0063 % 8 mA až 10 mA CMC 0,0061 % 10 mA až 13 mA CMC 0,0059 % 13 mA až 19 mA CMC 0,0057 % 19 mA až 22 mA CMC 0,0055 % 22 mA až 30 mA CMC 0,0098 % 30 mA až 40 mA CMC 0,0088 % 40 mA až 50 mA CMC 0,0082 % 50 mA až 60 mA CMC 0,0077 % 60 mA až 70 mA CMC 0,0075 % 70 mA až 80 mA CMC 0,0073 % 80 mA až 180 mA CMC 0,0072 % 180 mA až 220 mA CMC 0,0075 % 220 mA až 300 mA CMC 0,020 % 300 mA až 400 mA CMC 0,017 % 400 mA až 600 mA CMC 0,015 % 600 mA až 900 mA CMC 0,013 % 900 mA až 1 A CMC 0,011 % 1 A až 1,4 A CMC 0,012 % 1,4 A až 1,8 A CMC 0,013 % 1,8 A až 2 A CMC 0,014 % 2 A až 2,2 A CMC 0,015 % 2,2 A až 3 A CMC 0,044 % 3 A až 4 A CMC 0,041 % 4 A až 5 A CMC 0,038 % 5 A až 6 A CMC 0,037 % 6 A až 7 A CMC 0,036 % 7 A až 8 A CMC 0,035 % 8 A až 11 A CMC 0,034 % 11 A až 20,2 A CMC 0,033 % 20,2 A až 23 A CMC 0,043 % 23 A až 30 A CMC 0,042 % 30 A až 45 A CMC 0,083 % 45 A až 60 A CMC 0,067 % 60 A až 90 A CMC 0,058 % TP3, TP21 Prad staly / Mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 µA do 20 µA CMC 10 nA od 20 µA do 30 µA CMC 0,046 % od 30 µA do 40 µA CMC 0,032 % od 40 µA do 50 µA CMC 0,026 % od 50 µA do 60 µA CMC 0,022 % od 60 µA do 70 µA CMC 0,019 % od 70 µA do 95 µA CMC 0,017 % od 95 µA do 120 µA CMC 0,014 % od 120 µA do 170 µA CMC 0,012 % od 170 µA do 200 µA CMC 0,0099 % od 200 µA do 220 µA CMC 0,0092 % od 220 µA do 300 µA CMC 0,0088 % od 300 µA do 400 µA CMC 0,0078 % od 400 µA do 500 µA CMC 0,0071 % od 500 µA do 600 µA CMC 0,0067 % od 600 µA do 700 µA CMC 0,0065 % od 700 µA do 800 µA CMC 0,0063 % od 800 µA do 1 mA CMC 0,0061 % od 1 mA do 1,3 mA CMC 0,0059 % od 1,3 mA do 1,9 mA CMC 0,0057 % od 1,9 mA do 2,2 mA CMC 0,0055 % od 2,2 mA do 3 mA CMC 0,0088 % od 3 mA do 4 mA CMC 0,0078 % od 4 mA do 5 mA CMC 0,0071 % od 5 mA do 6 mA CMC 0,0067 % od 6 mA do 7 mA CMC 0,0065 % od 7 mA do 8 mA CMC 0,0063 % od 8 mA do 10 mA CMC 0,0061 % od 10 mA do 13 mA CMC 0,0059 % od 13 mA do 19 mA CMC 0,0057 % od 19 mA do 22 mA CMC 0,0055 % od 22 mA do 30 mA CMC 0,0098 % od 30 mA do 40 mA CMC 0,0088 % od 40 mA do 50 mA CMC 0,0082 % od 50 mA do 60 mA CMC 0,0077 % od 60 mA do 70 mA CMC 0,0075 % od 70 mA do 80 mA CMC 0,0073 % od 80 mA do 180 mA CMC 0,0072 % od 180 mA do 220 mA CMC 0,0075 % od 220 mA do 300 mA CMC 0,020 % od 300 mA do 400 mA CMC 0,017 % od 400 mA do 600 mA CMC 0,015 % od 600 mA do 900 mA CMC 0,013 % od 900 mA do 1 A CMC 0,011 % od 1 A do 1,4 A CMC 0,012 % od 1,4 A do 1,8 A CMC 0,013 % od 1,8 A do 2 A CMC 0,014 % od 2 A do 2,2 A CMC 0,015 % od 2,2 A do 3 A CMC 0,044 % od 3 A do 4 A CMC 0,041 % od 4 A do 5 A CMC 0,038 % od 5 A do 6 A CMC 0,037 % od 6 A do 7 A CMC 0,036 % od 7 A do 8 A CMC 0,035 % od 8 A do 11 A CMC 0,034 % od 11 A do 20,2 A CMC 0,033 % od 20,2 A do 23 A CMC 0,043 % od 23 A do 30 A CMC 0,042 % od 30 A do 45 A CMC 0,083 % od 45 A do 60 A CMC 0,067 % od 60 A do 90 A CMC 0,058 % Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 µA az 20 µA CMC 10 nA 20 µA az 30 µA CMC 0,046 % 30 µA az 40 µA CMC 0,032 % 40 µA az 50 µA CMC 0,026 % 50 µA az 60 µA CMC 0,022 % 60 µA az 70 µA CMC 0,019 % 70 µA az 95 µA CMC 0,017 % 95 µA az 120 µA CMC 0,014 % 120 µA az 170 µA CMC 0,012 % 170 µA az 200 µA CMC 0,0099 % 200 µA az 220 µA CMC 0,0092 % 220 µA az 300 µA CMC 0,0088 % 300 µA az 400 µA CMC 0,0078 % 400 µA az 500 µA CMC 0,0071 % 500 µA az 600 µA CMC 0,0067 % 600 µA az 700 µA CMC 0,0065 % 700 µA az 800 µA CMC 0,0063 % 800 µA az 1 mA CMC 0,0061 % 1 mA az 1,3 mA CMC 0,0059 % 1,3 mA az 1,9 mA CMC 0,0057 % 1,9 mA az 2,2 mA CMC 0,0055 % 2,2 mA az 3 mA CMC 0,0088 % 3 mA az 4 mA CMC 0,0078 % 4 mA az 5 mA CMC 0,0071 % 5 mA az 6 mA CMC 0,0067 % 6 mA az 7 mA CMC 0,0065 % 7 mA az 8 mA CMC 0,0063 % 8 mA az 10 mA CMC 0,0061 % 10 mA az 13 mA CMC 0,0059 % 13 mA az 19 mA CMC 0,0057 % 19 mA az 22 mA CMC 0,0055 % 22 mA az 30 mA CMC 0,0098 % 30 mA az 40 mA CMC 0,0088 % 40 mA az 50 mA CMC 0,0082 % 50 mA az 60 mA CMC 0,0077 % 60 mA az 70 mA CMC 0,0075 % 70 mA az 80 mA CMC 0,0073 % 80 mA az 180 mA CMC 0,0072 % 180 mA az 220 mA CMC 0,0075 % 220 mA az 300 mA CMC 0,020 % 300 mA az 400 mA CMC 0,017 % 400 mA az 600 mA CMC 0,015 % 600 mA az 900 mA CMC 0,013 % 900 mA az 1 A CMC 0,011 % 1 A az 1,4 A CMC 0,012 % 1,4 A az 1,8 A CMC 0,013 % 1,8 A az 2 A CMC 0,014 % 2 A az 2,2 A CMC 0,015 % 2,2 A az 3 A CMC 0,044 % 3 A az 4 A CMC 0,041 % 4 A az 5 A CMC 0,038 % 5 A az 6 A CMC 0,037 % 6 A az 7 A CMC 0,036 % 7 A az 8 A CMC 0,035 % 8 A az 11 A CMC 0,034 % 11 A az 20,2 A CMC 0,033 % 20,2 A az 23 A CMC 0,043 % 23 A az 30 A CMC 0,042 % 30 A az 45 A CMC 0,083 % 45 A az 60 A CMC 0,067 % 60 A az 90 A CMC 0,058 % TP3, TP21","search_en":"DC current / DC current meters Calibration – electrical quantities Direct generation with a calibrator 0 µA to 20 µA CMC 10 nA 20 µA to 30 µA CMC 0,046 % 30 µA to 40 µA CMC 0,032 % 40 µA to 50 µA CMC 0,026 % 50 µA to 60 µA CMC 0,022 % 60 µA to 70 µA CMC 0,019 % 70 µA to 95 µA CMC 0,017 % 95 µA to 120 µA CMC 0,014 % 120 µA to 170 µA CMC 0,012 % 170 µA to 200 µA CMC 0,0099 % 200 µA to 220 µA CMC 0,0092 % 220 µA to 300 µA CMC 0,0088 % 300 µA to 400 µA CMC 0,0078 % 400 µA to 500 µA CMC 0,0071 % 500 µA to 600 µA CMC 0,0067 % 600 µA to 700 µA CMC 0,0065 % 700 µA to 800 µA CMC 0,0063 % 800 µA to 1 mA CMC 0,0061 % 1 mA to 1,3 mA CMC 0,0059 % 1,3 mA to 1,9 mA CMC 0,0057 % 1,9 mA to 2,2 mA CMC 0,0055 % 2,2 mA to 3 mA CMC 0,0088 % 3 mA to 4 mA CMC 0,0078 % 4 mA to 5 mA CMC 0,0071 % 5 mA to 6 mA CMC 0,0067 % 6 mA to 7 mA CMC 0,0065 % 7 mA to 8 mA CMC 0,0063 % 8 mA to 10 mA CMC 0,0061 % 10 mA to 13 mA CMC 0,0059 % 13 mA to 19 mA CMC 0,0057 % 19 mA to 22 mA CMC 0,0055 % 22 mA to 30 mA CMC 0,0098 % 30 mA to 40 mA CMC 0,0088 % 40 mA to 50 mA CMC 0,0082 % 50 mA to 60 mA CMC 0,0077 % 60 mA to 70 mA CMC 0,0075 % 70 mA to 80 mA CMC 0,0073 % 80 mA to 180 mA CMC 0,0072 % 180 mA to 220 mA CMC 0,0075 % 220 mA to 300 mA CMC 0,020 % 300 mA to 400 mA CMC 0,017 % 400 mA to 600 mA CMC 0,015 % 600 mA to 900 mA CMC 0,013 % 900 mA to 1 A CMC 0,011 % 1 A to 1,4 A CMC 0,012 % 1,4 A to 1,8 A CMC 0,013 % 1,8 A to 2 A CMC 0,014 % 2 A to 2,2 A CMC 0,015 % 2,2 A to 3 A CMC 0,044 % 3 A to 4 A CMC 0,041 % 4 A to 5 A CMC 0,038 % 5 A to 6 A CMC 0,037 % 6 A to 7 A CMC 0,036 % 7 A to 8 A CMC 0,035 % 8 A to 11 A CMC 0,034 % 11 A to 20,2 A CMC 0,033 % 20,2 A to 23 A CMC 0,043 % 23 A to 30 A CMC 0,042 % 30 A to 45 A CMC 0,083 % 45 A to 60 A CMC 0,067 % 60 A to 90 A CMC 0,058 % TP3, TP21","search_zh":"直流电流 / 直流电流测量仪器 校准 – 电学量 用校准器直接产生 0 µA 至 20 µA CMC 10 nA 20 µA 至 30 µA CMC 0,046 % 30 µA 至 40 µA CMC 0,032 % 40 µA 至 50 µA CMC 0,026 % 50 µA 至 60 µA CMC 0,022 % 60 µA 至 70 µA CMC 0,019 % 70 µA 至 95 µA CMC 0,017 % 95 µA 至 120 µA CMC 0,014 % 120 µA 至 170 µA CMC 0,012 % 170 µA 至 200 µA CMC 0,0099 % 200 µA 至 220 µA CMC 0,0092 % 220 µA 至 300 µA CMC 0,0088 % 300 µA 至 400 µA CMC 0,0078 % 400 µA 至 500 µA CMC 0,0071 % 500 µA 至 600 µA CMC 0,0067 % 600 µA 至 700 µA CMC 0,0065 % 700 µA 至 800 µA CMC 0,0063 % 800 µA 至 1 mA CMC 0,0061 % 1 mA 至 1,3 mA CMC 0,0059 % 1,3 mA 至 1,9 mA CMC 0,0057 % 1,9 mA 至 2,2 mA CMC 0,0055 % 2,2 mA 至 3 mA CMC 0,0088 % 3 mA 至 4 mA CMC 0,0078 % 4 mA 至 5 mA CMC 0,0071 % 5 mA 至 6 mA CMC 0,0067 % 6 mA 至 7 mA CMC 0,0065 % 7 mA 至 8 mA CMC 0,0063 % 8 mA 至 10 mA CMC 0,0061 % 10 mA 至 13 mA CMC 0,0059 % 13 mA 至 19 mA CMC 0,0057 % 19 mA 至 22 mA CMC 0,0055 % 22 mA 至 30 mA CMC 0,0098 % 30 mA 至 40 mA CMC 0,0088 % 40 mA 至 50 mA CMC 0,0082 % 50 mA 至 60 mA CMC 0,0077 % 60 mA 至 70 mA CMC 0,0075 % 70 mA 至 80 mA CMC 0,0073 % 80 mA 至 180 mA CMC 0,0072 % 180 mA 至 220 mA CMC 0,0075 % 220 mA 至 300 mA CMC 0,020 % 300 mA 至 400 mA CMC 0,017 % 400 mA 至 600 mA CMC 0,015 % 600 mA 至 900 mA CMC 0,013 % 900 mA 至 1 A CMC 0,011 % 1 A 至 1,4 A CMC 0,012 % 1,4 A 至 1,8 A CMC 0,013 % 1,8 A 至 2 A CMC 0,014 % 2 A 至 2,2 A CMC 0,015 % 2,2 A 至 3 A CMC 0,044 % 3 A 至 4 A CMC 0,041 % 4 A 至 5 A CMC 0,038 % 5 A 至 6 A CMC 0,037 % 6 A 至 7 A CMC 0,036 % 7 A 至 8 A CMC 0,035 % 8 A 至 11 A CMC 0,034 % 11 A 至 20,2 A CMC 0,033 % 20,2 A 至 23 A CMC 0,043 % 23 A 至 30 A CMC 0,042 % 30 A 至 45 A CMC 0,083 % 45 A 至 60 A CMC 0,067 % 60 A 至 90 A CMC 0,058 % TP3, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a0e6d6b773aa096578298370","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"3","test_object":"Prąd stały / Mierniki prądu stałego","test_object_en":"DC current / DC current meters","test_object_zh":"直流电流 / 直流电流测量仪器","test_object_cs":"Stejnosměrný proud / Měřidla stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 90 A do 2250 A","cmc":"0,40 %"}],"parameters_en":[{"name":"","range":"90 A to 2250 A","cmc":"0,40 %"}],"parameters_zh":[{"name":"","range":"90 A 至 2250 A","cmc":"0,40 %"}],"parameters_cs":[{"name":"","range":"90 A až 2250 A","cmc":"0,40 %"}],"technique":"Pośrednie generowanie kalibratorem z cewką prądową","technique_en":"Indirect generation with a calibrator with a current coil","technique_zh":"用带电流线圈的校准器间接产生","technique_cs":"Nepřímé generování kalibrátorem s proudovou cívkou","techniques":["Pośrednie generowanie kalibratorem z cewką prądową"],"techniques_en":["Indirect generation with a calibrator with a current coil"],"techniques_zh":["用带电流线圈的校准器间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 90 A do 2250 A CMC 0,40 %\nPośrednie generowanie kalibratorem z cewką prądową","reference":"TP3, TP21","norm_bases":["TP3","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / Mierniki prądu stałego Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z cewką prądową od 90 A do 2250 A CMC 0,40 % Stejnosměrný proud / Měřidla stejnosměrného proudu Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem s proudovou cívkou 90 A až 2250 A CMC 0,40 % TP3, TP21 Prad staly / Mierniki pradu stalego Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z cewka pradowa od 90 A do 2250 A CMC 0,40 % Stejnosmerny proud / Meridla stejnosmerneho proudu Kalibrace – elektricke veliciny Neprime generovani kalibratorem s proudovou civkou 90 A az 2250 A CMC 0,40 % TP3, TP21","search_en":"DC current / DC current meters Calibration – electrical quantities Indirect generation with a calibrator with a current coil 90 A to 2250 A CMC 0,40 % TP3, TP21","search_zh":"直流电流 / 直流电流测量仪器 校准 – 电学量 用带电流线圈的校准器间接产生 90 A 至 2250 A CMC 0,40 % TP3, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd44e7a68db8cf3c418a271d","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / Źródła prądu przemiennego","test_object_en":"AC current / AC current sources","test_object_zh":"交流电流 / 交流电流源","test_object_cs":"Střídavý proud / Zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 10 kHz","range":"od 10 µA do 20 µA","cmc":"30 nA"},{"name":"10 Hz do 10 kHz","range":"od 20 µA do 30 µA","cmc":"0,15 %"},{"name":"10 Hz do 10 kHz","range":"od 30 µA do 40 µA","cmc":"0,12 %"},{"name":"10 Hz do 10 kHz","range":"od 40 µA do 50 µA","cmc":"0,098 %"},{"name":"10 Hz do 10 kHz","range":"od 50 µA do 60 µA","cmc":"0,088 %"},{"name":"10 Hz do 10 kHz","range":"od 60 µA do 70 µA","cmc":"0,081 %"},{"name":"10 Hz do 10 kHz","range":"od 70 µA do 80 µA","cmc":"0,077 %"},{"name":"10 Hz do 10 kHz","range":"od 80 µA do 90 mA","cmc":"0,073 %"},{"name":"10 Hz do 10 kHz","range":"od 90 µA do 100 µA","cmc":"0,070 %"},{"name":"10 Hz do 10 kHz","range":"od 100 µA do 110 µA","cmc":"0,068 %"},{"name":"10 Hz do 10 kHz","range":"od 110 µA do 130 µA","cmc":"0,066 %"},{"name":"10 Hz do 10 kHz","range":"od 130 µA do 150 µA","cmc":"0,063 %"},{"name":"10 Hz do 10 kHz","range":"od 150 µA do 180 µA","cmc":"0,061 %"},{"name":"10 Hz do 10 kHz","range":"od 180 µA do 200 µA","cmc":"0,059 %"},{"name":"10 Hz do 10 kHz","range":"od 200 µA do 250 µA","cmc":"0,13 %"},{"name":"10 Hz do 10 kHz","range":"od 250 µA do 300 µA","cmc":"0,11 %"},{"name":"10 Hz do 10 kHz","range":"od 300 µA do 400 µA","cmc":"0,095 %"},{"name":"10 Hz do 10 kHz","range":"od 400 µA do 500 µA","cmc":"0,079 %"},{"name":"10 Hz do 10 kHz","range":"od 500 µA do 600 µA","cmc":"0,069 %"},{"name":"10 Hz do 10 kHz","range":"od 600 µA do 700 µA","cmc":"0,062 %"},{"name":"10 Hz do 10 kHz","range":"od 700 µA do 800 µA","cmc":"0,057 %"},{"name":"10 Hz do 10 kHz","range":"od 800 µA do 900 µA","cmc":"0,054 %"},{"name":"10 Hz do 10 kHz","range":"od 900 µA do 1 mA","cmc":"0,051 %"},{"name":"10 Hz do 10 kHz","range":"od 1 mA do 1,1 mA","cmc":"0,049 %"},{"name":"10 Hz do 10 kHz","range":"od 1,1 mA do 1,2 mA","cmc":"0,047 %"},{"name":"10 Hz do 10 kHz","range":"od 1,2 mA do 1,4 mA","cmc":"0,045 %"},{"name":"10 Hz do 10 kHz","range":"od 1,4 mA do 1,6 mA","cmc":"0,043 %"},{"name":"10 Hz do 10 kHz","range":"od 1,6 mA do 1,9 mA","cmc":"0,041 %"},{"name":"10 Hz do 10 kHz","range":"od 1,9 mA do 2 mA","cmc":"0,039 %"},{"name":"10 Hz do 10 kHz","range":"od 2 mA do 2,5 mA","cmc":"0,13 %"},{"name":"10 Hz do 10 kHz","range":"od 2,5 mA do 3 mA","cmc":"0,11 %"},{"name":"10 Hz do 10 kHz","range":"od 3 mA do 4 mA","cmc":"0,095 %"},{"name":"10 Hz do 10 kHz","range":"od 4 mA do 5 mA","cmc":"0,079 %"},{"name":"10 Hz do 10 kHz","range":"od 5 mA do 6 mA","cmc":"0,069 %"},{"name":"10 Hz do 10 kHz","range":"od 6 mA do 7 mA","cmc":"0,062 %"},{"name":"10 Hz do 10 kHz","range":"od 7 mA do 8 mA","cmc":"0,057 %"},{"name":"10 Hz do 10 kHz","range":"od 8 mA do 9 mA","cmc":"0,054 %"},{"name":"10 Hz do 10 kHz","range":"od 9 mA do 10 mA","cmc":"0,051 %"},{"name":"10 Hz do 10 kHz","range":"od 10 mA do 11 mA","cmc":"0,049 %"},{"name":"10 Hz do 10 kHz","range":"od 11 mA do 12 mA","cmc":"0,047 %"},{"name":"10 Hz do 10 kHz","range":"od 12 mA do 14 mA","cmc":"0,045 %"},{"name":"10 Hz do 10 kHz","range":"od 14 mA do 16 mA","cmc":"0,043 %"},{"name":"10 Hz do 10 kHz","range":"od 16 mA do 19 mA","cmc":"0,041 %"},{"name":"10 Hz do 10 kHz","range":"od 19 mA do 20 mA","cmc":"0,039 %"},{"name":"10 Hz do 10 kHz","range":"od 20 mA do 25 mA","cmc":"0,13 %"},{"name":"10 Hz do 10 kHz","range":"od 25 mA do 30 mA","cmc":"0,11 %"},{"name":"10 Hz do 10 kHz","range":"od 30 mA do 40 mA","cmc":"0,092 %"},{"name":"10 Hz do 10 kHz","range":"od 40 mA do 50 mA","cmc":"0,076 %"},{"name":"10 Hz do 10 kHz","range":"od 50 mA do 60 mA","cmc":"0,066 %"},{"name":"10 Hz do 10 kHz","range":"od 60 mA do 70 mA","cmc":"0,059 %"},{"name":"10 Hz do 10 kHz","range":"od 70 mA do 80 mA","cmc":"0,054 %"},{"name":"10 Hz do 10 kHz","range":"od 80 mA do 90 mA","cmc":"0,051 %"},{"name":"10 Hz do 10 kHz","range":"od 90 mA do 100 mA","cmc":"0,048 %"},{"name":"10 Hz do 10 kHz","range":"od 100 mA do 110 mA","cmc":"0,046 %"},{"name":"10 Hz do 10 kHz","range":"od 110 mA do 120 mA","cmc":"0,044 %"},{"name":"10 Hz do 10 kHz","range":"od 120 mA do 140 mA","cmc":"0,042 %"},{"name":"10 Hz do 10 kHz","range":"od 140 mA do 160 mA","cmc":"0,040 %"},{"name":"10 Hz do 10 kHz","range":"od 160 mA do 190 mA","cmc":"0,038 %"},{"name":"10 Hz do 10 kHz","range":"od 190 mA do 200 mA","cmc":"0,036 %"},{"name":"10 Hz do 2 kHz","range":"od 200 mA do 250 mA","cmc":"0,17 %"},{"name":"2 kHz do 10 kHz","range":"od 200 mA do 250 mA","cmc":"0,18 %"},{"name":"10 Hz do 2 kHz","range":"od 250 mA do 300 mA","cmc":"0,15 %"},{"name":"2 kHz do 10 kHz","range":"od 250 mA do 300 mA","cmc":"0,16 %"},{"name":"10 Hz do 2 kHz","range":"od 300 mA do 400 mA","cmc":"0,13 %"},{"name":"2 kHz do 10 kHz","range":"od 300 mA do 400 mA","cmc":"0,14 %"},{"name":"10 Hz do 2 kHz","range":"od 400 mA do 500 mA","cmc":"0,12 %"},{"name":"2 kHz do 10 kHz","range":"od 400 mA do 500 mA","cmc":"0,13 %"},{"name":"10 Hz do 2 kHz","range":"od 500 mA do 600 mA","cmc":"0,11 %"},{"name":"2 kHz do 10 kHz","range":"od 500 mA do 600 mA","cmc":"0,12 %"},{"name":"10 Hz do 2 kHz","range":"od 600 mA do 700 mA","cmc":"0,094 %"},{"name":"2 kHz do 10 kHz","range":"od 600 mA do 700 mA","cmc":"0,11 %"},{"name":"10 Hz do 2 kHz","range":"od 700 mA do 800 mA","cmc":"0,089 %"},{"name":"2 kHz do 10 kHz","range":"od 700 mA do 800 mA","cmc":"0,099 %"},{"name":"10 Hz do 2 kHz","range":"od 800 mA do 900 mA","cmc":"0,086 %"},{"name":"2 kHz do 10 kHz","range":"od 800 mA do 900 mA","cmc":"0,096 %"},{"name":"10 Hz do 2 kHz","range":"od 900 mA do 1 A","cmc":"0,083 %"},{"name":"2 kHz do 10 kHz","range":"od 900 mA do 1 A","cmc":"0,093 %"},{"name":"10 Hz do 2 kHz","range":"od 1 A do 1,1 A","cmc":"0,081 %"},{"name":"2 kHz do 10 kHz","range":"od 1 A do 1,1 A","cmc":"0,091 %"},{"name":"10 Hz do 2 kHz","range":"od 1,1 A do 1,2 A","cmc":"0,079 %"},{"name":"2 kHz do 10 kHz","range":"od 1,1 A do 1,2 A","cmc":"0,089 %"},{"name":"10 Hz do 2 kHz","range":"od 1,2 A do 1,3 A","cmc":"0,077 %"},{"name":"2 kHz do 10 kHz","range":"od 1,2 A do 1,3 A","cmc":"0,087 %"},{"name":"10 Hz do 2 kHz","range":"od 1,3 A do 1,4 A","cmc":"0,076 %"},{"name":"2 kHz do 10 kHz","range":"od 1,3 A do 1,4 A","cmc":"0,087 %"},{"name":"10 Hz do 2 kHz","range":"od 1,4 A do 1,5 A","cmc":"0,076 %"},{"name":"2 kHz do 10 kHz","range":"od 1,4 A do 1,5 A","cmc":"0,085 %"},{"name":"10 Hz do 2 kHz","range":"od 1,5 A do 1,6 A","cmc":"0,074 %"},{"name":"2 kHz do 10 kHz","range":"od 1,5 A do 1,6 A","cmc":"0,085 %"},{"name":"10 Hz do 2 kHz","range":"od 1,6 A do 1,7 A","cmc":"0,074 %"},{"name":"2 kHz do 10 kHz","range":"od 1,6 A do 1,7 A","cmc":"0,083 %"},{"name":"10 Hz do 2 kHz","range":"od 1,7 A do 2 A","cmc":"0,072 %"},{"name":"2 kHz do 10 kHz","range":"od 1,7 A do 2 A","cmc":"0,083 %"},{"name":"10 Hz do 2 kHz","range":"od 2 A do 2,5 A","cmc":"0,19 %"},{"name":"2 kHz do 10 kHz","range":"od 2 A do 2,5 A","cmc":"0,36 %"},{"name":"10 Hz do 2 kHz","range":"od 2,5 A do 3 A","cmc":"0,16 %"},{"name":"2 kHz do 10 kHz","range":"od 2,5 A do 3 A","cmc":"0,34 %"},{"name":"10 Hz do 2 kHz","range":"od 3 A do 4 A","cmc":"0,15 %"},{"name":"2 kHz do 10 kHz","range":"od 3 A do 4 A","cmc":"0,32 %"},{"name":"10 Hz do 2 kHz","range":"od 4 A do 5 A","cmc":"0,14 %"},{"name":"2 kHz do 10 kHz","range":"od 4 A do 5 A","cmc":"0,31 %"},{"name":"10 Hz do 2 kHz","range":"od 5 A do 6 A","cmc":"0,13 %"},{"name":"2 kHz do 10 kHz","range":"od 5 A do 6 A","cmc":"0,30 %"},{"name":"10 Hz do 2 kHz","range":"od 6 A do 7 A","cmc":"0,12 %"},{"name":"2 kHz do 10 kHz","range":"od 6 A do 7 A","cmc":"0,29 %"},{"name":"10 Hz do 2 kHz","range":"od 7 A do 11 A","cmc":"0,11 %"},{"name":"2 kHz do 10 kHz","range":"od 7 A do 11 A","cmc":"0,28 %"},{"name":"10 Hz do 2 kHz","range":"od 11 A do 20 A","cmc":"0,10 %"},{"name":"2 kHz do 10 kHz","range":"od 11 A do 20 A","cmc":"0,27 %"},{"name":"50 Hz","range":"od 200 mA do 250 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"od 250 mA do 300 mA","cmc":"0,057 %"},{"name":"50 Hz","range":"od 300 mA do 400 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"od 400 mA do 500 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"od 500 mA do 600 mA","cmc":"0,056 %"},{"name":"50 Hz","range":"od 600 mA do 800 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"od 800 mA do 1 A","cmc":"0,067 %"},{"name":"50 Hz","range":"od 1 A do 1,3 A","cmc":"0,056 %"},{"name":"50 Hz","range":"od 1,3 A do 2 A","cmc":"0,079 %"},{"name":"50 Hz","range":"od 2 A do 2,6 A","cmc":"0,056 %"},{"name":"50 Hz","range":"od 2,6 A do 5 A","cmc":"0,070 %"},{"name":"50 Hz","range":"od 5 A do 5,2 A","cmc":"0,048 %"},{"name":"50 Hz","range":"od 5,2 A do 9 A","cmc":"0,070 %"},{"name":"50 Hz","range":"od 9 A do 10 A","cmc":"0,050 %"},{"name":"50 Hz","range":"od 10 A do 1200 A","cmc":"0,04 %"}],"parameters_en":[{"name":"10 Hz to 10 kHz","range":"10 µA to 20 µA","cmc":"30 nA"},{"name":"10 Hz to 10 kHz","range":"20 µA to 30 µA","cmc":"0,15 %"},{"name":"10 Hz to 10 kHz","range":"30 µA to 40 µA","cmc":"0,12 %"},{"name":"10 Hz to 10 kHz","range":"40 µA to 50 µA","cmc":"0,098 %"},{"name":"10 Hz to 10 kHz","range":"50 µA to 60 µA","cmc":"0,088 %"},{"name":"10 Hz to 10 kHz","range":"60 µA to 70 µA","cmc":"0,081 %"},{"name":"10 Hz to 10 kHz","range":"70 µA to 80 µA","cmc":"0,077 %"},{"name":"10 Hz to 10 kHz","range":"80 µA to 90 mA","cmc":"0,073 %"},{"name":"10 Hz to 10 kHz","range":"90 µA to 100 µA","cmc":"0,070 %"},{"name":"10 Hz to 10 kHz","range":"100 µA to 110 µA","cmc":"0,068 %"},{"name":"10 Hz to 10 kHz","range":"110 µA to 130 µA","cmc":"0,066 %"},{"name":"10 Hz to 10 kHz","range":"130 µA to 150 µA","cmc":"0,063 %"},{"name":"10 Hz to 10 kHz","range":"150 µA to 180 µA","cmc":"0,061 %"},{"name":"10 Hz to 10 kHz","range":"180 µA to 200 µA","cmc":"0,059 %"},{"name":"10 Hz to 10 kHz","range":"200 µA to 250 µA","cmc":"0,13 %"},{"name":"10 Hz to 10 kHz","range":"250 µA to 300 µA","cmc":"0,11 %"},{"name":"10 Hz to 10 kHz","range":"300 µA to 400 µA","cmc":"0,095 %"},{"name":"10 Hz to 10 kHz","range":"400 µA to 500 µA","cmc":"0,079 %"},{"name":"10 Hz to 10 kHz","range":"500 µA to 600 µA","cmc":"0,069 %"},{"name":"10 Hz to 10 kHz","range":"600 µA to 700 µA","cmc":"0,062 %"},{"name":"10 Hz to 10 kHz","range":"700 µA to 800 µA","cmc":"0,057 %"},{"name":"10 Hz to 10 kHz","range":"800 µA to 900 µA","cmc":"0,054 %"},{"name":"10 Hz to 10 kHz","range":"900 µA to 1 mA","cmc":"0,051 %"},{"name":"10 Hz to 10 kHz","range":"1 mA to 1,1 mA","cmc":"0,049 %"},{"name":"10 Hz to 10 kHz","range":"1,1 mA to 1,2 mA","cmc":"0,047 %"},{"name":"10 Hz to 10 kHz","range":"1,2 mA to 1,4 mA","cmc":"0,045 %"},{"name":"10 Hz to 10 kHz","range":"1,4 mA to 1,6 mA","cmc":"0,043 %"},{"name":"10 Hz to 10 kHz","range":"1,6 mA to 1,9 mA","cmc":"0,041 %"},{"name":"10 Hz to 10 kHz","range":"1,9 mA to 2 mA","cmc":"0,039 %"},{"name":"10 Hz to 10 kHz","range":"2 mA to 2,5 mA","cmc":"0,13 %"},{"name":"10 Hz to 10 kHz","range":"2,5 mA to 3 mA","cmc":"0,11 %"},{"name":"10 Hz to 10 kHz","range":"3 mA to 4 mA","cmc":"0,095 %"},{"name":"10 Hz to 10 kHz","range":"4 mA to 5 mA","cmc":"0,079 %"},{"name":"10 Hz to 10 kHz","range":"5 mA to 6 mA","cmc":"0,069 %"},{"name":"10 Hz to 10 kHz","range":"6 mA to 7 mA","cmc":"0,062 %"},{"name":"10 Hz to 10 kHz","range":"7 mA to 8 mA","cmc":"0,057 %"},{"name":"10 Hz to 10 kHz","range":"8 mA to 9 mA","cmc":"0,054 %"},{"name":"10 Hz to 10 kHz","range":"9 mA to 10 mA","cmc":"0,051 %"},{"name":"10 Hz to 10 kHz","range":"10 mA to 11 mA","cmc":"0,049 %"},{"name":"10 Hz to 10 kHz","range":"11 mA to 12 mA","cmc":"0,047 %"},{"name":"10 Hz to 10 kHz","range":"12 mA to 14 mA","cmc":"0,045 %"},{"name":"10 Hz to 10 kHz","range":"14 mA to 16 mA","cmc":"0,043 %"},{"name":"10 Hz to 10 kHz","range":"16 mA to 19 mA","cmc":"0,041 %"},{"name":"10 Hz to 10 kHz","range":"19 mA to 20 mA","cmc":"0,039 %"},{"name":"10 Hz to 10 kHz","range":"20 mA to 25 mA","cmc":"0,13 %"},{"name":"10 Hz to 10 kHz","range":"25 mA to 30 mA","cmc":"0,11 %"},{"name":"10 Hz to 10 kHz","range":"30 mA to 40 mA","cmc":"0,092 %"},{"name":"10 Hz to 10 kHz","range":"40 mA to 50 mA","cmc":"0,076 %"},{"name":"10 Hz to 10 kHz","range":"50 mA to 60 mA","cmc":"0,066 %"},{"name":"10 Hz to 10 kHz","range":"60 mA to 70 mA","cmc":"0,059 %"},{"name":"10 Hz to 10 kHz","range":"70 mA to 80 mA","cmc":"0,054 %"},{"name":"10 Hz to 10 kHz","range":"80 mA to 90 mA","cmc":"0,051 %"},{"name":"10 Hz to 10 kHz","range":"90 mA to 100 mA","cmc":"0,048 %"},{"name":"10 Hz to 10 kHz","range":"100 mA to 110 mA","cmc":"0,046 %"},{"name":"10 Hz to 10 kHz","range":"110 mA to 120 mA","cmc":"0,044 %"},{"name":"10 Hz to 10 kHz","range":"120 mA to 140 mA","cmc":"0,042 %"},{"name":"10 Hz to 10 kHz","range":"140 mA to 160 mA","cmc":"0,040 %"},{"name":"10 Hz to 10 kHz","range":"160 mA to 190 mA","cmc":"0,038 %"},{"name":"10 Hz to 10 kHz","range":"190 mA to 200 mA","cmc":"0,036 %"},{"name":"10 Hz to 2 kHz","range":"200 mA to 250 mA","cmc":"0,17 %"},{"name":"2 kHz to 10 kHz","range":"200 mA to 250 mA","cmc":"0,18 %"},{"name":"10 Hz to 2 kHz","range":"250 mA to 300 mA","cmc":"0,15 %"},{"name":"2 kHz to 10 kHz","range":"250 mA to 300 mA","cmc":"0,16 %"},{"name":"10 Hz to 2 kHz","range":"300 mA to 400 mA","cmc":"0,13 %"},{"name":"2 kHz to 10 kHz","range":"300 mA to 400 mA","cmc":"0,14 %"},{"name":"10 Hz to 2 kHz","range":"400 mA to 500 mA","cmc":"0,12 %"},{"name":"2 kHz to 10 kHz","range":"400 mA to 500 mA","cmc":"0,13 %"},{"name":"10 Hz to 2 kHz","range":"500 mA to 600 mA","cmc":"0,11 %"},{"name":"2 kHz to 10 kHz","range":"500 mA to 600 mA","cmc":"0,12 %"},{"name":"10 Hz to 2 kHz","range":"600 mA to 700 mA","cmc":"0,094 %"},{"name":"2 kHz to 10 kHz","range":"600 mA to 700 mA","cmc":"0,11 %"},{"name":"10 Hz to 2 kHz","range":"700 mA to 800 mA","cmc":"0,089 %"},{"name":"2 kHz to 10 kHz","range":"700 mA to 800 mA","cmc":"0,099 %"},{"name":"10 Hz to 2 kHz","range":"800 mA to 900 mA","cmc":"0,086 %"},{"name":"2 kHz to 10 kHz","range":"800 mA to 900 mA","cmc":"0,096 %"},{"name":"10 Hz to 2 kHz","range":"900 mA to 1 A","cmc":"0,083 %"},{"name":"2 kHz to 10 kHz","range":"900 mA to 1 A","cmc":"0,093 %"},{"name":"10 Hz to 2 kHz","range":"1 A to 1,1 A","cmc":"0,081 %"},{"name":"2 kHz to 10 kHz","range":"1 A to 1,1 A","cmc":"0,091 %"},{"name":"10 Hz to 2 kHz","range":"1,1 A to 1,2 A","cmc":"0,079 %"},{"name":"2 kHz to 10 kHz","range":"1,1 A to 1,2 A","cmc":"0,089 %"},{"name":"10 Hz to 2 kHz","range":"1,2 A to 1,3 A","cmc":"0,077 %"},{"name":"2 kHz to 10 kHz","range":"1,2 A to 1,3 A","cmc":"0,087 %"},{"name":"10 Hz to 2 kHz","range":"1,3 A to 1,4 A","cmc":"0,076 %"},{"name":"2 kHz to 10 kHz","range":"1,3 A to 1,4 A","cmc":"0,087 %"},{"name":"10 Hz to 2 kHz","range":"1,4 A to 1,5 A","cmc":"0,076 %"},{"name":"2 kHz to 10 kHz","range":"1,4 A to 1,5 A","cmc":"0,085 %"},{"name":"10 Hz to 2 kHz","range":"1,5 A to 1,6 A","cmc":"0,074 %"},{"name":"2 kHz to 10 kHz","range":"1,5 A to 1,6 A","cmc":"0,085 %"},{"name":"10 Hz to 2 kHz","range":"1,6 A to 1,7 A","cmc":"0,074 %"},{"name":"2 kHz to 10 kHz","range":"1,6 A to 1,7 A","cmc":"0,083 %"},{"name":"10 Hz to 2 kHz","range":"1,7 A to 2 A","cmc":"0,072 %"},{"name":"2 kHz to 10 kHz","range":"1,7 A to 2 A","cmc":"0,083 %"},{"name":"10 Hz to 2 kHz","range":"2 A to 2,5 A","cmc":"0,19 %"},{"name":"2 kHz to 10 kHz","range":"2 A to 2,5 A","cmc":"0,36 %"},{"name":"10 Hz to 2 kHz","range":"2,5 A to 3 A","cmc":"0,16 %"},{"name":"2 kHz to 10 kHz","range":"2,5 A to 3 A","cmc":"0,34 %"},{"name":"10 Hz to 2 kHz","range":"3 A to 4 A","cmc":"0,15 %"},{"name":"2 kHz to 10 kHz","range":"3 A to 4 A","cmc":"0,32 %"},{"name":"10 Hz to 2 kHz","range":"4 A to 5 A","cmc":"0,14 %"},{"name":"2 kHz to 10 kHz","range":"4 A to 5 A","cmc":"0,31 %"},{"name":"10 Hz to 2 kHz","range":"5 A to 6 A","cmc":"0,13 %"},{"name":"2 kHz to 10 kHz","range":"5 A to 6 A","cmc":"0,30 %"},{"name":"10 Hz to 2 kHz","range":"6 A to 7 A","cmc":"0,12 %"},{"name":"2 kHz to 10 kHz","range":"6 A to 7 A","cmc":"0,29 %"},{"name":"10 Hz to 2 kHz","range":"7 A to 11 A","cmc":"0,11 %"},{"name":"2 kHz to 10 kHz","range":"7 A to 11 A","cmc":"0,28 %"},{"name":"10 Hz to 2 kHz","range":"11 A to 20 A","cmc":"0,10 %"},{"name":"2 kHz to 10 kHz","range":"11 A to 20 A","cmc":"0,27 %"},{"name":"50 Hz","range":"200 mA to 250 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"250 mA to 300 mA","cmc":"0,057 %"},{"name":"50 Hz","range":"300 mA to 400 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"400 mA to 500 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"500 mA to 600 mA","cmc":"0,056 %"},{"name":"50 Hz","range":"600 mA to 800 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"800 mA to 1 A","cmc":"0,067 %"},{"name":"50 Hz","range":"1 A to 1,3 A","cmc":"0,056 %"},{"name":"50 Hz","range":"1,3 A to 2 A","cmc":"0,079 %"},{"name":"50 Hz","range":"2 A to 2,6 A","cmc":"0,056 %"},{"name":"50 Hz","range":"2,6 A to 5 A","cmc":"0,070 %"},{"name":"50 Hz","range":"5 A to 5,2 A","cmc":"0,048 %"},{"name":"50 Hz","range":"5,2 A to 9 A","cmc":"0,070 %"},{"name":"50 Hz","range":"9 A to 10 A","cmc":"0,050 %"},{"name":"50 Hz","range":"10 A to 1200 A","cmc":"0,04 %"}],"parameters_zh":[{"name":"10 Hz 至 10 kHz","range":"10 µA 至 20 µA","cmc":"30 nA"},{"name":"10 Hz 至 10 kHz","range":"20 µA 至 30 µA","cmc":"0,15 %"},{"name":"10 Hz 至 10 kHz","range":"30 µA 至 40 µA","cmc":"0,12 %"},{"name":"10 Hz 至 10 kHz","range":"40 µA 至 50 µA","cmc":"0,098 %"},{"name":"10 Hz 至 10 kHz","range":"50 µA 至 60 µA","cmc":"0,088 %"},{"name":"10 Hz 至 10 kHz","range":"60 µA 至 70 µA","cmc":"0,081 %"},{"name":"10 Hz 至 10 kHz","range":"70 µA 至 80 µA","cmc":"0,077 %"},{"name":"10 Hz 至 10 kHz","range":"80 µA 至 90 mA","cmc":"0,073 %"},{"name":"10 Hz 至 10 kHz","range":"90 µA 至 100 µA","cmc":"0,070 %"},{"name":"10 Hz 至 10 kHz","range":"100 µA 至 110 µA","cmc":"0,068 %"},{"name":"10 Hz 至 10 kHz","range":"110 µA 至 130 µA","cmc":"0,066 %"},{"name":"10 Hz 至 10 kHz","range":"130 µA 至 150 µA","cmc":"0,063 %"},{"name":"10 Hz 至 10 kHz","range":"150 µA 至 180 µA","cmc":"0,061 %"},{"name":"10 Hz 至 10 kHz","range":"180 µA 至 200 µA","cmc":"0,059 %"},{"name":"10 Hz 至 10 kHz","range":"200 µA 至 250 µA","cmc":"0,13 %"},{"name":"10 Hz 至 10 kHz","range":"250 µA 至 300 µA","cmc":"0,11 %"},{"name":"10 Hz 至 10 kHz","range":"300 µA 至 400 µA","cmc":"0,095 %"},{"name":"10 Hz 至 10 kHz","range":"400 µA 至 500 µA","cmc":"0,079 %"},{"name":"10 Hz 至 10 kHz","range":"500 µA 至 600 µA","cmc":"0,069 %"},{"name":"10 Hz 至 10 kHz","range":"600 µA 至 700 µA","cmc":"0,062 %"},{"name":"10 Hz 至 10 kHz","range":"700 µA 至 800 µA","cmc":"0,057 %"},{"name":"10 Hz 至 10 kHz","range":"800 µA 至 900 µA","cmc":"0,054 %"},{"name":"10 Hz 至 10 kHz","range":"900 µA 至 1 mA","cmc":"0,051 %"},{"name":"10 Hz 至 10 kHz","range":"1 mA 至 1,1 mA","cmc":"0,049 %"},{"name":"10 Hz 至 10 kHz","range":"1,1 mA 至 1,2 mA","cmc":"0,047 %"},{"name":"10 Hz 至 10 kHz","range":"1,2 mA 至 1,4 mA","cmc":"0,045 %"},{"name":"10 Hz 至 10 kHz","range":"1,4 mA 至 1,6 mA","cmc":"0,043 %"},{"name":"10 Hz 至 10 kHz","range":"1,6 mA 至 1,9 mA","cmc":"0,041 %"},{"name":"10 Hz 至 10 kHz","range":"1,9 mA 至 2 mA","cmc":"0,039 %"},{"name":"10 Hz 至 10 kHz","range":"2 mA 至 2,5 mA","cmc":"0,13 %"},{"name":"10 Hz 至 10 kHz","range":"2,5 mA 至 3 mA","cmc":"0,11 %"},{"name":"10 Hz 至 10 kHz","range":"3 mA 至 4 mA","cmc":"0,095 %"},{"name":"10 Hz 至 10 kHz","range":"4 mA 至 5 mA","cmc":"0,079 %"},{"name":"10 Hz 至 10 kHz","range":"5 mA 至 6 mA","cmc":"0,069 %"},{"name":"10 Hz 至 10 kHz","range":"6 mA 至 7 mA","cmc":"0,062 %"},{"name":"10 Hz 至 10 kHz","range":"7 mA 至 8 mA","cmc":"0,057 %"},{"name":"10 Hz 至 10 kHz","range":"8 mA 至 9 mA","cmc":"0,054 %"},{"name":"10 Hz 至 10 kHz","range":"9 mA 至 10 mA","cmc":"0,051 %"},{"name":"10 Hz 至 10 kHz","range":"10 mA 至 11 mA","cmc":"0,049 %"},{"name":"10 Hz 至 10 kHz","range":"11 mA 至 12 mA","cmc":"0,047 %"},{"name":"10 Hz 至 10 kHz","range":"12 mA 至 14 mA","cmc":"0,045 %"},{"name":"10 Hz 至 10 kHz","range":"14 mA 至 16 mA","cmc":"0,043 %"},{"name":"10 Hz 至 10 kHz","range":"16 mA 至 19 mA","cmc":"0,041 %"},{"name":"10 Hz 至 10 kHz","range":"19 mA 至 20 mA","cmc":"0,039 %"},{"name":"10 Hz 至 10 kHz","range":"20 mA 至 25 mA","cmc":"0,13 %"},{"name":"10 Hz 至 10 kHz","range":"25 mA 至 30 mA","cmc":"0,11 %"},{"name":"10 Hz 至 10 kHz","range":"30 mA 至 40 mA","cmc":"0,092 %"},{"name":"10 Hz 至 10 kHz","range":"40 mA 至 50 mA","cmc":"0,076 %"},{"name":"10 Hz 至 10 kHz","range":"50 mA 至 60 mA","cmc":"0,066 %"},{"name":"10 Hz 至 10 kHz","range":"60 mA 至 70 mA","cmc":"0,059 %"},{"name":"10 Hz 至 10 kHz","range":"70 mA 至 80 mA","cmc":"0,054 %"},{"name":"10 Hz 至 10 kHz","range":"80 mA 至 90 mA","cmc":"0,051 %"},{"name":"10 Hz 至 10 kHz","range":"90 mA 至 100 mA","cmc":"0,048 %"},{"name":"10 Hz 至 10 kHz","range":"100 mA 至 110 mA","cmc":"0,046 %"},{"name":"10 Hz 至 10 kHz","range":"110 mA 至 120 mA","cmc":"0,044 %"},{"name":"10 Hz 至 10 kHz","range":"120 mA 至 140 mA","cmc":"0,042 %"},{"name":"10 Hz 至 10 kHz","range":"140 mA 至 160 mA","cmc":"0,040 %"},{"name":"10 Hz 至 10 kHz","range":"160 mA 至 190 mA","cmc":"0,038 %"},{"name":"10 Hz 至 10 kHz","range":"190 mA 至 200 mA","cmc":"0,036 %"},{"name":"10 Hz 至 2 kHz","range":"200 mA 至 250 mA","cmc":"0,17 %"},{"name":"2 kHz 至 10 kHz","range":"200 mA 至 250 mA","cmc":"0,18 %"},{"name":"10 Hz 至 2 kHz","range":"250 mA 至 300 mA","cmc":"0,15 %"},{"name":"2 kHz 至 10 kHz","range":"250 mA 至 300 mA","cmc":"0,16 %"},{"name":"10 Hz 至 2 kHz","range":"300 mA 至 400 mA","cmc":"0,13 %"},{"name":"2 kHz 至 10 kHz","range":"300 mA 至 400 mA","cmc":"0,14 %"},{"name":"10 Hz 至 2 kHz","range":"400 mA 至 500 mA","cmc":"0,12 %"},{"name":"2 kHz 至 10 kHz","range":"400 mA 至 500 mA","cmc":"0,13 %"},{"name":"10 Hz 至 2 kHz","range":"500 mA 至 600 mA","cmc":"0,11 %"},{"name":"2 kHz 至 10 kHz","range":"500 mA 至 600 mA","cmc":"0,12 %"},{"name":"10 Hz 至 2 kHz","range":"600 mA 至 700 mA","cmc":"0,094 %"},{"name":"2 kHz 至 10 kHz","range":"600 mA 至 700 mA","cmc":"0,11 %"},{"name":"10 Hz 至 2 kHz","range":"700 mA 至 800 mA","cmc":"0,089 %"},{"name":"2 kHz 至 10 kHz","range":"700 mA 至 800 mA","cmc":"0,099 %"},{"name":"10 Hz 至 2 kHz","range":"800 mA 至 900 mA","cmc":"0,086 %"},{"name":"2 kHz 至 10 kHz","range":"800 mA 至 900 mA","cmc":"0,096 %"},{"name":"10 Hz 至 2 kHz","range":"900 mA 至 1 A","cmc":"0,083 %"},{"name":"2 kHz 至 10 kHz","range":"900 mA 至 1 A","cmc":"0,093 %"},{"name":"10 Hz 至 2 kHz","range":"1 A 至 1,1 A","cmc":"0,081 %"},{"name":"2 kHz 至 10 kHz","range":"1 A 至 1,1 A","cmc":"0,091 %"},{"name":"10 Hz 至 2 kHz","range":"1,1 A 至 1,2 A","cmc":"0,079 %"},{"name":"2 kHz 至 10 kHz","range":"1,1 A 至 1,2 A","cmc":"0,089 %"},{"name":"10 Hz 至 2 kHz","range":"1,2 A 至 1,3 A","cmc":"0,077 %"},{"name":"2 kHz 至 10 kHz","range":"1,2 A 至 1,3 A","cmc":"0,087 %"},{"name":"10 Hz 至 2 kHz","range":"1,3 A 至 1,4 A","cmc":"0,076 %"},{"name":"2 kHz 至 10 kHz","range":"1,3 A 至 1,4 A","cmc":"0,087 %"},{"name":"10 Hz 至 2 kHz","range":"1,4 A 至 1,5 A","cmc":"0,076 %"},{"name":"2 kHz 至 10 kHz","range":"1,4 A 至 1,5 A","cmc":"0,085 %"},{"name":"10 Hz 至 2 kHz","range":"1,5 A 至 1,6 A","cmc":"0,074 %"},{"name":"2 kHz 至 10 kHz","range":"1,5 A 至 1,6 A","cmc":"0,085 %"},{"name":"10 Hz 至 2 kHz","range":"1,6 A 至 1,7 A","cmc":"0,074 %"},{"name":"2 kHz 至 10 kHz","range":"1,6 A 至 1,7 A","cmc":"0,083 %"},{"name":"10 Hz 至 2 kHz","range":"1,7 A 至 2 A","cmc":"0,072 %"},{"name":"2 kHz 至 10 kHz","range":"1,7 A 至 2 A","cmc":"0,083 %"},{"name":"10 Hz 至 2 kHz","range":"2 A 至 2,5 A","cmc":"0,19 %"},{"name":"2 kHz 至 10 kHz","range":"2 A 至 2,5 A","cmc":"0,36 %"},{"name":"10 Hz 至 2 kHz","range":"2,5 A 至 3 A","cmc":"0,16 %"},{"name":"2 kHz 至 10 kHz","range":"2,5 A 至 3 A","cmc":"0,34 %"},{"name":"10 Hz 至 2 kHz","range":"3 A 至 4 A","cmc":"0,15 %"},{"name":"2 kHz 至 10 kHz","range":"3 A 至 4 A","cmc":"0,32 %"},{"name":"10 Hz 至 2 kHz","range":"4 A 至 5 A","cmc":"0,14 %"},{"name":"2 kHz 至 10 kHz","range":"4 A 至 5 A","cmc":"0,31 %"},{"name":"10 Hz 至 2 kHz","range":"5 A 至 6 A","cmc":"0,13 %"},{"name":"2 kHz 至 10 kHz","range":"5 A 至 6 A","cmc":"0,30 %"},{"name":"10 Hz 至 2 kHz","range":"6 A 至 7 A","cmc":"0,12 %"},{"name":"2 kHz 至 10 kHz","range":"6 A 至 7 A","cmc":"0,29 %"},{"name":"10 Hz 至 2 kHz","range":"7 A 至 11 A","cmc":"0,11 %"},{"name":"2 kHz 至 10 kHz","range":"7 A 至 11 A","cmc":"0,28 %"},{"name":"10 Hz 至 2 kHz","range":"11 A 至 20 A","cmc":"0,10 %"},{"name":"2 kHz 至 10 kHz","range":"11 A 至 20 A","cmc":"0,27 %"},{"name":"50 Hz","range":"200 mA 至 250 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"250 mA 至 300 mA","cmc":"0,057 %"},{"name":"50 Hz","range":"300 mA 至 400 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"400 mA 至 500 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"500 mA 至 600 mA","cmc":"0,056 %"},{"name":"50 Hz","range":"600 mA 至 800 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"800 mA 至 1 A","cmc":"0,067 %"},{"name":"50 Hz","range":"1 A 至 1,3 A","cmc":"0,056 %"},{"name":"50 Hz","range":"1,3 A 至 2 A","cmc":"0,079 %"},{"name":"50 Hz","range":"2 A 至 2,6 A","cmc":"0,056 %"},{"name":"50 Hz","range":"2,6 A 至 5 A","cmc":"0,070 %"},{"name":"50 Hz","range":"5 A 至 5,2 A","cmc":"0,048 %"},{"name":"50 Hz","range":"5,2 A 至 9 A","cmc":"0,070 %"},{"name":"50 Hz","range":"9 A 至 10 A","cmc":"0,050 %"},{"name":"50 Hz","range":"10 A 至 1200 A","cmc":"0,04 %"}],"parameters_cs":[{"name":"10 Hz až 10 kHz","range":"10 µA až 20 µA","cmc":"30 nA"},{"name":"10 Hz až 10 kHz","range":"20 µA až 30 µA","cmc":"0,15 %"},{"name":"10 Hz až 10 kHz","range":"30 µA až 40 µA","cmc":"0,12 %"},{"name":"10 Hz až 10 kHz","range":"40 µA až 50 µA","cmc":"0,098 %"},{"name":"10 Hz až 10 kHz","range":"50 µA až 60 µA","cmc":"0,088 %"},{"name":"10 Hz až 10 kHz","range":"60 µA až 70 µA","cmc":"0,081 %"},{"name":"10 Hz až 10 kHz","range":"70 µA až 80 µA","cmc":"0,077 %"},{"name":"10 Hz až 10 kHz","range":"80 µA až 90 mA","cmc":"0,073 %"},{"name":"10 Hz až 10 kHz","range":"90 µA až 100 µA","cmc":"0,070 %"},{"name":"10 Hz až 10 kHz","range":"100 µA až 110 µA","cmc":"0,068 %"},{"name":"10 Hz až 10 kHz","range":"110 µA až 130 µA","cmc":"0,066 %"},{"name":"10 Hz až 10 kHz","range":"130 µA až 150 µA","cmc":"0,063 %"},{"name":"10 Hz až 10 kHz","range":"150 µA až 180 µA","cmc":"0,061 %"},{"name":"10 Hz až 10 kHz","range":"180 µA až 200 µA","cmc":"0,059 %"},{"name":"10 Hz až 10 kHz","range":"200 µA až 250 µA","cmc":"0,13 %"},{"name":"10 Hz až 10 kHz","range":"250 µA až 300 µA","cmc":"0,11 %"},{"name":"10 Hz až 10 kHz","range":"300 µA až 400 µA","cmc":"0,095 %"},{"name":"10 Hz až 10 kHz","range":"400 µA až 500 µA","cmc":"0,079 %"},{"name":"10 Hz až 10 kHz","range":"500 µA až 600 µA","cmc":"0,069 %"},{"name":"10 Hz až 10 kHz","range":"600 µA až 700 µA","cmc":"0,062 %"},{"name":"10 Hz až 10 kHz","range":"700 µA až 800 µA","cmc":"0,057 %"},{"name":"10 Hz až 10 kHz","range":"800 µA až 900 µA","cmc":"0,054 %"},{"name":"10 Hz až 10 kHz","range":"900 µA až 1 mA","cmc":"0,051 %"},{"name":"10 Hz až 10 kHz","range":"1 mA až 1,1 mA","cmc":"0,049 %"},{"name":"10 Hz až 10 kHz","range":"1,1 mA až 1,2 mA","cmc":"0,047 %"},{"name":"10 Hz až 10 kHz","range":"1,2 mA až 1,4 mA","cmc":"0,045 %"},{"name":"10 Hz až 10 kHz","range":"1,4 mA až 1,6 mA","cmc":"0,043 %"},{"name":"10 Hz až 10 kHz","range":"1,6 mA až 1,9 mA","cmc":"0,041 %"},{"name":"10 Hz až 10 kHz","range":"1,9 mA až 2 mA","cmc":"0,039 %"},{"name":"10 Hz až 10 kHz","range":"2 mA až 2,5 mA","cmc":"0,13 %"},{"name":"10 Hz až 10 kHz","range":"2,5 mA až 3 mA","cmc":"0,11 %"},{"name":"10 Hz až 10 kHz","range":"3 mA až 4 mA","cmc":"0,095 %"},{"name":"10 Hz až 10 kHz","range":"4 mA až 5 mA","cmc":"0,079 %"},{"name":"10 Hz až 10 kHz","range":"5 mA až 6 mA","cmc":"0,069 %"},{"name":"10 Hz až 10 kHz","range":"6 mA až 7 mA","cmc":"0,062 %"},{"name":"10 Hz až 10 kHz","range":"7 mA až 8 mA","cmc":"0,057 %"},{"name":"10 Hz až 10 kHz","range":"8 mA až 9 mA","cmc":"0,054 %"},{"name":"10 Hz až 10 kHz","range":"9 mA až 10 mA","cmc":"0,051 %"},{"name":"10 Hz až 10 kHz","range":"10 mA až 11 mA","cmc":"0,049 %"},{"name":"10 Hz až 10 kHz","range":"11 mA až 12 mA","cmc":"0,047 %"},{"name":"10 Hz až 10 kHz","range":"12 mA až 14 mA","cmc":"0,045 %"},{"name":"10 Hz až 10 kHz","range":"14 mA až 16 mA","cmc":"0,043 %"},{"name":"10 Hz až 10 kHz","range":"16 mA až 19 mA","cmc":"0,041 %"},{"name":"10 Hz až 10 kHz","range":"19 mA až 20 mA","cmc":"0,039 %"},{"name":"10 Hz až 10 kHz","range":"20 mA až 25 mA","cmc":"0,13 %"},{"name":"10 Hz až 10 kHz","range":"25 mA až 30 mA","cmc":"0,11 %"},{"name":"10 Hz až 10 kHz","range":"30 mA až 40 mA","cmc":"0,092 %"},{"name":"10 Hz až 10 kHz","range":"40 mA až 50 mA","cmc":"0,076 %"},{"name":"10 Hz až 10 kHz","range":"50 mA až 60 mA","cmc":"0,066 %"},{"name":"10 Hz až 10 kHz","range":"60 mA až 70 mA","cmc":"0,059 %"},{"name":"10 Hz až 10 kHz","range":"70 mA až 80 mA","cmc":"0,054 %"},{"name":"10 Hz až 10 kHz","range":"80 mA až 90 mA","cmc":"0,051 %"},{"name":"10 Hz až 10 kHz","range":"90 mA až 100 mA","cmc":"0,048 %"},{"name":"10 Hz až 10 kHz","range":"100 mA až 110 mA","cmc":"0,046 %"},{"name":"10 Hz až 10 kHz","range":"110 mA až 120 mA","cmc":"0,044 %"},{"name":"10 Hz až 10 kHz","range":"120 mA až 140 mA","cmc":"0,042 %"},{"name":"10 Hz až 10 kHz","range":"140 mA až 160 mA","cmc":"0,040 %"},{"name":"10 Hz až 10 kHz","range":"160 mA až 190 mA","cmc":"0,038 %"},{"name":"10 Hz až 10 kHz","range":"190 mA až 200 mA","cmc":"0,036 %"},{"name":"10 Hz až 2 kHz","range":"200 mA až 250 mA","cmc":"0,17 %"},{"name":"2 kHz až 10 kHz","range":"200 mA až 250 mA","cmc":"0,18 %"},{"name":"10 Hz až 2 kHz","range":"250 mA až 300 mA","cmc":"0,15 %"},{"name":"2 kHz až 10 kHz","range":"250 mA až 300 mA","cmc":"0,16 %"},{"name":"10 Hz až 2 kHz","range":"300 mA až 400 mA","cmc":"0,13 %"},{"name":"2 kHz až 10 kHz","range":"300 mA až 400 mA","cmc":"0,14 %"},{"name":"10 Hz až 2 kHz","range":"400 mA až 500 mA","cmc":"0,12 %"},{"name":"2 kHz až 10 kHz","range":"400 mA až 500 mA","cmc":"0,13 %"},{"name":"10 Hz až 2 kHz","range":"500 mA až 600 mA","cmc":"0,11 %"},{"name":"2 kHz až 10 kHz","range":"500 mA až 600 mA","cmc":"0,12 %"},{"name":"10 Hz až 2 kHz","range":"600 mA až 700 mA","cmc":"0,094 %"},{"name":"2 kHz až 10 kHz","range":"600 mA až 700 mA","cmc":"0,11 %"},{"name":"10 Hz až 2 kHz","range":"700 mA až 800 mA","cmc":"0,089 %"},{"name":"2 kHz až 10 kHz","range":"700 mA až 800 mA","cmc":"0,099 %"},{"name":"10 Hz až 2 kHz","range":"800 mA až 900 mA","cmc":"0,086 %"},{"name":"2 kHz až 10 kHz","range":"800 mA až 900 mA","cmc":"0,096 %"},{"name":"10 Hz až 2 kHz","range":"900 mA až 1 A","cmc":"0,083 %"},{"name":"2 kHz až 10 kHz","range":"900 mA až 1 A","cmc":"0,093 %"},{"name":"10 Hz až 2 kHz","range":"1 A až 1,1 A","cmc":"0,081 %"},{"name":"2 kHz až 10 kHz","range":"1 A až 1,1 A","cmc":"0,091 %"},{"name":"10 Hz až 2 kHz","range":"1,1 A až 1,2 A","cmc":"0,079 %"},{"name":"2 kHz až 10 kHz","range":"1,1 A až 1,2 A","cmc":"0,089 %"},{"name":"10 Hz až 2 kHz","range":"1,2 A až 1,3 A","cmc":"0,077 %"},{"name":"2 kHz až 10 kHz","range":"1,2 A až 1,3 A","cmc":"0,087 %"},{"name":"10 Hz až 2 kHz","range":"1,3 A až 1,4 A","cmc":"0,076 %"},{"name":"2 kHz až 10 kHz","range":"1,3 A až 1,4 A","cmc":"0,087 %"},{"name":"10 Hz až 2 kHz","range":"1,4 A až 1,5 A","cmc":"0,076 %"},{"name":"2 kHz až 10 kHz","range":"1,4 A až 1,5 A","cmc":"0,085 %"},{"name":"10 Hz až 2 kHz","range":"1,5 A až 1,6 A","cmc":"0,074 %"},{"name":"2 kHz až 10 kHz","range":"1,5 A až 1,6 A","cmc":"0,085 %"},{"name":"10 Hz až 2 kHz","range":"1,6 A až 1,7 A","cmc":"0,074 %"},{"name":"2 kHz až 10 kHz","range":"1,6 A až 1,7 A","cmc":"0,083 %"},{"name":"10 Hz až 2 kHz","range":"1,7 A až 2 A","cmc":"0,072 %"},{"name":"2 kHz až 10 kHz","range":"1,7 A až 2 A","cmc":"0,083 %"},{"name":"10 Hz až 2 kHz","range":"2 A až 2,5 A","cmc":"0,19 %"},{"name":"2 kHz až 10 kHz","range":"2 A až 2,5 A","cmc":"0,36 %"},{"name":"10 Hz až 2 kHz","range":"2,5 A až 3 A","cmc":"0,16 %"},{"name":"2 kHz až 10 kHz","range":"2,5 A až 3 A","cmc":"0,34 %"},{"name":"10 Hz až 2 kHz","range":"3 A až 4 A","cmc":"0,15 %"},{"name":"2 kHz až 10 kHz","range":"3 A až 4 A","cmc":"0,32 %"},{"name":"10 Hz až 2 kHz","range":"4 A až 5 A","cmc":"0,14 %"},{"name":"2 kHz až 10 kHz","range":"4 A až 5 A","cmc":"0,31 %"},{"name":"10 Hz až 2 kHz","range":"5 A až 6 A","cmc":"0,13 %"},{"name":"2 kHz až 10 kHz","range":"5 A až 6 A","cmc":"0,30 %"},{"name":"10 Hz až 2 kHz","range":"6 A až 7 A","cmc":"0,12 %"},{"name":"2 kHz až 10 kHz","range":"6 A až 7 A","cmc":"0,29 %"},{"name":"10 Hz až 2 kHz","range":"7 A až 11 A","cmc":"0,11 %"},{"name":"2 kHz až 10 kHz","range":"7 A až 11 A","cmc":"0,28 %"},{"name":"10 Hz až 2 kHz","range":"11 A až 20 A","cmc":"0,10 %"},{"name":"2 kHz až 10 kHz","range":"11 A až 20 A","cmc":"0,27 %"},{"name":"50 Hz","range":"200 mA až 250 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"250 mA až 300 mA","cmc":"0,057 %"},{"name":"50 Hz","range":"300 mA až 400 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"400 mA až 500 mA","cmc":"0,067 %"},{"name":"50 Hz","range":"500 mA až 600 mA","cmc":"0,056 %"},{"name":"50 Hz","range":"600 mA až 800 mA","cmc":"0,084 %"},{"name":"50 Hz","range":"800 mA až 1 A","cmc":"0,067 %"},{"name":"50 Hz","range":"1 A až 1,3 A","cmc":"0,056 %"},{"name":"50 Hz","range":"1,3 A až 2 A","cmc":"0,079 %"},{"name":"50 Hz","range":"2 A až 2,6 A","cmc":"0,056 %"},{"name":"50 Hz","range":"2,6 A až 5 A","cmc":"0,070 %"},{"name":"50 Hz","range":"5 A až 5,2 A","cmc":"0,048 %"},{"name":"50 Hz","range":"5,2 A až 9 A","cmc":"0,070 %"},{"name":"50 Hz","range":"9 A až 10 A","cmc":"0,050 %"},{"name":"50 Hz","range":"10 A až 1200 A","cmc":"0,04 %"}],"technique":"Pomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego, przekładnika prądowego","technique_en":"Direct measurement with a multimeter or indirect measurement with a current shunt, current transformer","technique_zh":"用万用表直接测量或借助电流分流器、电流互感器间接测量","technique_cs":"Přímé měření multimetrem nebo nepřímé měření pomocí proudového bočníku, proudového transformátoru","techniques":["Pomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego, przekładnika prądowego"],"techniques_en":["Direct measurement with a multimeter or indirect measurement with a current shunt, current transformer"],"techniques_zh":["用万用表直接测量或借助电流分流器、电流互感器间接测量"],"techniques_cs":["Přímé měření multimetrem nebo nepřímé měření pomocí proudového bočníku, proudového transformátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 10 kHz od 10 µA do 20 µA CMC 30 nA\n10 Hz do 10 kHz od 20 µA do 30 µA CMC 0,15 %\n10 Hz do 10 kHz od 30 µA do 40 µA CMC 0,12 %\n10 Hz do 10 kHz od 40 µA do 50 µA CMC 0,098 %\n10 Hz do 10 kHz od 50 µA do 60 µA CMC 0,088 %\n10 Hz do 10 kHz od 60 µA do 70 µA CMC 0,081 %\n10 Hz do 10 kHz od 70 µA do 80 µA CMC 0,077 %\n10 Hz do 10 kHz od 80 µA do 90 mA CMC 0,073 %\n10 Hz do 10 kHz od 90 µA do 100 µA CMC 0,070 %\n10 Hz do 10 kHz od 100 µA do 110 µA CMC 0,068 %\n10 Hz do 10 kHz od 110 µA do 130 µA CMC 0,066 %\n10 Hz do 10 kHz od 130 µA do 150 µA CMC 0,063 %\n10 Hz do 10 kHz od 150 µA do 180 µA CMC 0,061 %\n10 Hz do 10 kHz od 180 µA do 200 µA CMC 0,059 %\n10 Hz do 10 kHz od 200 µA do 250 µA CMC 0,13 %\n10 Hz do 10 kHz od 250 µA do 300 µA CMC 0,11 %\n10 Hz do 10 kHz od 300 µA do 400 µA CMC 0,095 %\n10 Hz do 10 kHz od 400 µA do 500 µA CMC 0,079 %\n10 Hz do 10 kHz od 500 µA do 600 µA CMC 0,069 %\n10 Hz do 10 kHz od 600 µA do 700 µA CMC 0,062 %\n10 Hz do 10 kHz od 700 µA do 800 µA CMC 0,057 %\n10 Hz do 10 kHz od 800 µA do 900 µA CMC 0,054 %\n10 Hz do 10 kHz od 900 µA do 1 mA CMC 0,051 %\n10 Hz do 10 kHz od 1 mA do 1,1 mA CMC 0,049 %\n10 Hz do 10 kHz od 1,1 mA do 1,2 mA CMC 0,047 %\n10 Hz do 10 kHz od 1,2 mA do 1,4 mA CMC 0,045 %\n10 Hz do 10 kHz od 1,4 mA do 1,6 mA CMC 0,043 %\n10 Hz do 10 kHz od 1,6 mA do 1,9 mA CMC 0,041 %\n10 Hz do 10 kHz od 1,9 mA do 2 mA CMC 0,039 %\n10 Hz do 10 kHz od 2 mA do 2,5 mA CMC 0,13 %\n10 Hz do 10 kHz od 2,5 mA do 3 mA CMC 0,11 %\n10 Hz do 10 kHz od 3 mA do 4 mA CMC 0,095 %\n10 Hz do 10 kHz od 4 mA do 5 mA CMC 0,079 %\n10 Hz do 10 kHz od 5 mA do 6 mA CMC 0,069 %\n10 Hz do 10 kHz od 6 mA do 7 mA CMC 0,062 %\n10 Hz do 10 kHz od 7 mA do 8 mA CMC 0,057 %\n10 Hz do 10 kHz od 8 mA do 9 mA CMC 0,054 %\n10 Hz do 10 kHz od 9 mA do 10 mA CMC 0,051 %\n10 Hz do 10 kHz od 10 mA do 11 mA CMC 0,049 %\n10 Hz do 10 kHz od 11 mA do 12 mA CMC 0,047 %\n10 Hz do 10 kHz od 12 mA do 14 mA CMC 0,045 %\n10 Hz do 10 kHz od 14 mA do 16 mA CMC 0,043 %\n10 Hz do 10 kHz od 16 mA do 19 mA CMC 0,041 %\n10 Hz do 10 kHz od 19 mA do 20 mA CMC 0,039 %\n10 Hz do 10 kHz od 20 mA do 25 mA CMC 0,13 %\n10 Hz do 10 kHz od 25 mA do 30 mA CMC 0,11 %\n10 Hz do 10 kHz od 30 mA do 40 mA CMC 0,092 %\n10 Hz do 10 kHz od 40 mA do 50 mA CMC 0,076 %\n10 Hz do 10 kHz od 50 mA do 60 mA CMC 0,066 %\n10 Hz do 10 kHz od 60 mA do 70 mA CMC 0,059 %\n10 Hz do 10 kHz od 70 mA do 80 mA CMC 0,054 %\n10 Hz do 10 kHz od 80 mA do 90 mA CMC 0,051 %\n10 Hz do 10 kHz od 90 mA do 100 mA CMC 0,048 %\n10 Hz do 10 kHz od 100 mA do 110 mA CMC 0,046 %\n10 Hz do 10 kHz od 110 mA do 120 mA CMC 0,044 %\n10 Hz do 10 kHz od 120 mA do 140 mA CMC 0,042 %\n10 Hz do 10 kHz od 140 mA do 160 mA CMC 0,040 %\n10 Hz do 10 kHz od 160 mA do 190 mA CMC 0,038 %\n10 Hz do 10 kHz od 190 mA do 200 mA CMC 0,036 %\n10 Hz do 2 kHz od 200 mA do 250 mA CMC 0,17 %\n2 kHz do 10 kHz od 200 mA do 250 mA CMC 0,18 %\n10 Hz do 2 kHz od 250 mA do 300 mA CMC 0,15 %\n2 kHz do 10 kHz od 250 mA do 300 mA CMC 0,16 %\n10 Hz do 2 kHz od 300 mA do 400 mA CMC 0,13 %\n2 kHz do 10 kHz od 300 mA do 400 mA CMC 0,14 %\n10 Hz do 2 kHz od 400 mA do 500 mA CMC 0,12 %\n2 kHz do 10 kHz od 400 mA do 500 mA CMC 0,13 %\n10 Hz do 2 kHz od 500 mA do 600 mA CMC 0,11 %\n2 kHz do 10 kHz od 500 mA do 600 mA CMC 0,12 %\n10 Hz do 2 kHz od 600 mA do 700 mA CMC 0,094 %\n2 kHz do 10 kHz od 600 mA do 700 mA CMC 0,11 %\n10 Hz do 2 kHz od 700 mA do 800 mA CMC 0,089 %\n2 kHz do 10 kHz od 700 mA do 800 mA CMC 0,099 %\n10 Hz do 2 kHz od 800 mA do 900 mA CMC 0,086 %\n2 kHz do 10 kHz od 800 mA do 900 mA CMC 0,096 %\n10 Hz do 2 kHz od 900 mA do 1 A CMC 0,083 %\n2 kHz do 10 kHz od 900 mA do 1 A CMC 0,093 %\n10 Hz do 2 kHz od 1 A do 1,1 A CMC 0,081 %\n2 kHz do 10 kHz od 1 A do 1,1 A CMC 0,091 %\n10 Hz do 2 kHz od 1,1 A do 1,2 A CMC 0,079 %\n2 kHz do 10 kHz od 1,1 A do 1,2 A CMC 0,089 %\n10 Hz do 2 kHz od 1,2 A do 1,3 A CMC 0,077 %\n2 kHz do 10 kHz od 1,2 A do 1,3 A CMC 0,087 %\n10 Hz do 2 kHz od 1,3 A do 1,4 A CMC 0,076 %\n2 kHz do 10 kHz od 1,3 A do 1,4 A CMC 0,087 %\n10 Hz do 2 kHz od 1,4 A do 1,5 A CMC 0,076 %\n2 kHz do 10 kHz od 1,4 A do 1,5 A CMC 0,085 %\n10 Hz do 2 kHz od 1,5 A do 1,6 A CMC 0,074 %\n2 kHz do 10 kHz od 1,5 A do 1,6 A CMC 0,085 %\n10 Hz do 2 kHz od 1,6 A do 1,7 A CMC 0,074 %\n2 kHz do 10 kHz od 1,6 A do 1,7 A CMC 0,083 %\n10 Hz do 2 kHz od 1,7 A do 2 A CMC 0,072 %\n2 kHz do 10 kHz od 1,7 A do 2 A CMC 0,083 %\n10 Hz do 2 kHz od 2 A do 2,5 A CMC 0,19 %\n2 kHz do 10 kHz od 2 A do 2,5 A CMC 0,36 %\n10 Hz do 2 kHz od 2,5 A do 3 A CMC 0,16 %\n2 kHz do 10 kHz od 2,5 A do 3 A CMC 0,34 %\n10 Hz do 2 kHz od 3 A do 4 A CMC 0,15 %\n2 kHz do 10 kHz od 3 A do 4 A CMC 0,32 %\n10 Hz do 2 kHz od 4 A do 5 A CMC 0,14 %\n2 kHz do 10 kHz od 4 A do 5 A CMC 0,31 %\n10 Hz do 2 kHz od 5 A do 6 A CMC 0,13 %\n2 kHz do 10 kHz od 5 A do 6 A CMC 0,30 %\n10 Hz do 2 kHz od 6 A do 7 A CMC 0,12 %\n2 kHz do 10 kHz od 6 A do 7 A CMC 0,29 %\n10 Hz do 2 kHz od 7 A do 11 A CMC 0,11 %\n2 kHz do 10 kHz od 7 A do 11 A CMC 0,28 %\n10 Hz do 2 kHz od 11 A do 20 A CMC 0,10 %\n2 kHz do 10 kHz od 11 A do 20 A CMC 0,27 %\n50 Hz od 200 mA do 250 mA CMC 0,067 %\n50 Hz od 250 mA do 300 mA CMC 0,057 %\n50 Hz od 300 mA do 400 mA CMC 0,084 %\n50 Hz od 400 mA do 500 mA CMC 0,067 %\n50 Hz od 500 mA do 600 mA CMC 0,056 %\n50 Hz od 600 mA do 800 mA CMC 0,084 %\n50 Hz od 800 mA do 1 A CMC 0,067 %\n50 Hz od 1 A do 1,3 A CMC 0,056 %\n50 Hz od 1,3 A do 2 A CMC 0,079 %\n50 Hz od 2 A do 2,6 A CMC 0,056 %\n50 Hz od 2,6 A do 5 A CMC 0,070 %\n50 Hz od 5 A do 5,2 A CMC 0,048 %\n50 Hz od 5,2 A do 9 A CMC 0,070 %\n50 Hz od 9 A do 10 A CMC 0,050 %\n50 Hz od 10 A do 1200 A CMC 0,04 %\nPomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego, przekładnika prądowego","reference":"TP4, TP21","norm_bases":["TP4","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / Źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem lub pomiar pośredni za pomocą bocznika prądowego, przekładnika prądowego 10 Hz do 10 kHz od 10 µA do 20 µA CMC 30 nA 10 Hz do 10 kHz od 20 µA do 30 µA CMC 0,15 % 10 Hz do 10 kHz od 30 µA do 40 µA CMC 0,12 % 10 Hz do 10 kHz od 40 µA do 50 µA CMC 0,098 % 10 Hz do 10 kHz od 50 µA do 60 µA CMC 0,088 % 10 Hz do 10 kHz od 60 µA do 70 µA CMC 0,081 % 10 Hz do 10 kHz od 70 µA do 80 µA CMC 0,077 % 10 Hz do 10 kHz od 80 µA do 90 mA CMC 0,073 % 10 Hz do 10 kHz od 90 µA do 100 µA CMC 0,070 % 10 Hz do 10 kHz od 100 µA do 110 µA CMC 0,068 % 10 Hz do 10 kHz od 110 µA do 130 µA CMC 0,066 % 10 Hz do 10 kHz od 130 µA do 150 µA CMC 0,063 % 10 Hz do 10 kHz od 150 µA do 180 µA CMC 0,061 % 10 Hz do 10 kHz od 180 µA do 200 µA CMC 0,059 % 10 Hz do 10 kHz od 200 µA do 250 µA CMC 0,13 % 10 Hz do 10 kHz od 250 µA do 300 µA CMC 0,11 % 10 Hz do 10 kHz od 300 µA do 400 µA CMC 0,095 % 10 Hz do 10 kHz od 400 µA do 500 µA CMC 0,079 % 10 Hz do 10 kHz od 500 µA do 600 µA CMC 0,069 % 10 Hz do 10 kHz od 600 µA do 700 µA CMC 0,062 % 10 Hz do 10 kHz od 700 µA do 800 µA CMC 0,057 % 10 Hz do 10 kHz od 800 µA do 900 µA CMC 0,054 % 10 Hz do 10 kHz od 900 µA do 1 mA CMC 0,051 % 10 Hz do 10 kHz od 1 mA do 1,1 mA CMC 0,049 % 10 Hz do 10 kHz od 1,1 mA do 1,2 mA CMC 0,047 % 10 Hz do 10 kHz od 1,2 mA do 1,4 mA CMC 0,045 % 10 Hz do 10 kHz od 1,4 mA do 1,6 mA CMC 0,043 % 10 Hz do 10 kHz od 1,6 mA do 1,9 mA CMC 0,041 % 10 Hz do 10 kHz od 1,9 mA do 2 mA CMC 0,039 % 10 Hz do 10 kHz od 2 mA do 2,5 mA CMC 0,13 % 10 Hz do 10 kHz od 2,5 mA do 3 mA CMC 0,11 % 10 Hz do 10 kHz od 3 mA do 4 mA CMC 0,095 % 10 Hz do 10 kHz od 4 mA do 5 mA CMC 0,079 % 10 Hz do 10 kHz od 5 mA do 6 mA CMC 0,069 % 10 Hz do 10 kHz od 6 mA do 7 mA CMC 0,062 % 10 Hz do 10 kHz od 7 mA do 8 mA CMC 0,057 % 10 Hz do 10 kHz od 8 mA do 9 mA CMC 0,054 % 10 Hz do 10 kHz od 9 mA do 10 mA CMC 0,051 % 10 Hz do 10 kHz od 10 mA do 11 mA CMC 0,049 % 10 Hz do 10 kHz od 11 mA do 12 mA CMC 0,047 % 10 Hz do 10 kHz od 12 mA do 14 mA CMC 0,045 % 10 Hz do 10 kHz od 14 mA do 16 mA CMC 0,043 % 10 Hz do 10 kHz od 16 mA do 19 mA CMC 0,041 % 10 Hz do 10 kHz od 19 mA do 20 mA CMC 0,039 % 10 Hz do 10 kHz od 20 mA do 25 mA CMC 0,13 % 10 Hz do 10 kHz od 25 mA do 30 mA CMC 0,11 % 10 Hz do 10 kHz od 30 mA do 40 mA CMC 0,092 % 10 Hz do 10 kHz od 40 mA do 50 mA CMC 0,076 % 10 Hz do 10 kHz od 50 mA do 60 mA CMC 0,066 % 10 Hz do 10 kHz od 60 mA do 70 mA CMC 0,059 % 10 Hz do 10 kHz od 70 mA do 80 mA CMC 0,054 % 10 Hz do 10 kHz od 80 mA do 90 mA CMC 0,051 % 10 Hz do 10 kHz od 90 mA do 100 mA CMC 0,048 % 10 Hz do 10 kHz od 100 mA do 110 mA CMC 0,046 % 10 Hz do 10 kHz od 110 mA do 120 mA CMC 0,044 % 10 Hz do 10 kHz od 120 mA do 140 mA CMC 0,042 % 10 Hz do 10 kHz od 140 mA do 160 mA CMC 0,040 % 10 Hz do 10 kHz od 160 mA do 190 mA CMC 0,038 % 10 Hz do 10 kHz od 190 mA do 200 mA CMC 0,036 % 10 Hz do 2 kHz od 200 mA do 250 mA CMC 0,17 % 2 kHz do 10 kHz od 200 mA do 250 mA CMC 0,18 % 10 Hz do 2 kHz od 250 mA do 300 mA CMC 0,15 % 2 kHz do 10 kHz od 250 mA do 300 mA CMC 0,16 % 10 Hz do 2 kHz od 300 mA do 400 mA CMC 0,13 % 2 kHz do 10 kHz od 300 mA do 400 mA CMC 0,14 % 10 Hz do 2 kHz od 400 mA do 500 mA CMC 0,12 % 2 kHz do 10 kHz od 400 mA do 500 mA CMC 0,13 % 10 Hz do 2 kHz od 500 mA do 600 mA CMC 0,11 % 2 kHz do 10 kHz od 500 mA do 600 mA CMC 0,12 % 10 Hz do 2 kHz od 600 mA do 700 mA CMC 0,094 % 2 kHz do 10 kHz od 600 mA do 700 mA CMC 0,11 % 10 Hz do 2 kHz od 700 mA do 800 mA CMC 0,089 % 2 kHz do 10 kHz od 700 mA do 800 mA CMC 0,099 % 10 Hz do 2 kHz od 800 mA do 900 mA CMC 0,086 % 2 kHz do 10 kHz od 800 mA do 900 mA CMC 0,096 % 10 Hz do 2 kHz od 900 mA do 1 A CMC 0,083 % 2 kHz do 10 kHz od 900 mA do 1 A CMC 0,093 % 10 Hz do 2 kHz od 1 A do 1,1 A CMC 0,081 % 2 kHz do 10 kHz od 1 A do 1,1 A CMC 0,091 % 10 Hz do 2 kHz od 1,1 A do 1,2 A CMC 0,079 % 2 kHz do 10 kHz od 1,1 A do 1,2 A CMC 0,089 % 10 Hz do 2 kHz od 1,2 A do 1,3 A CMC 0,077 % 2 kHz do 10 kHz od 1,2 A do 1,3 A CMC 0,087 % 10 Hz do 2 kHz od 1,3 A do 1,4 A CMC 0,076 % 2 kHz do 10 kHz od 1,3 A do 1,4 A CMC 0,087 % 10 Hz do 2 kHz od 1,4 A do 1,5 A CMC 0,076 % 2 kHz do 10 kHz od 1,4 A do 1,5 A CMC 0,085 % 10 Hz do 2 kHz od 1,5 A do 1,6 A CMC 0,074 % 2 kHz do 10 kHz od 1,5 A do 1,6 A CMC 0,085 % 10 Hz do 2 kHz od 1,6 A do 1,7 A CMC 0,074 % 2 kHz do 10 kHz od 1,6 A do 1,7 A CMC 0,083 % 10 Hz do 2 kHz od 1,7 A do 2 A CMC 0,072 % 2 kHz do 10 kHz od 1,7 A do 2 A CMC 0,083 % 10 Hz do 2 kHz od 2 A do 2,5 A CMC 0,19 % 2 kHz do 10 kHz od 2 A do 2,5 A CMC 0,36 % 10 Hz do 2 kHz od 2,5 A do 3 A CMC 0,16 % 2 kHz do 10 kHz od 2,5 A do 3 A CMC 0,34 % 10 Hz do 2 kHz od 3 A do 4 A CMC 0,15 % 2 kHz do 10 kHz od 3 A do 4 A CMC 0,32 % 10 Hz do 2 kHz od 4 A do 5 A CMC 0,14 % 2 kHz do 10 kHz od 4 A do 5 A CMC 0,31 % 10 Hz do 2 kHz od 5 A do 6 A CMC 0,13 % 2 kHz do 10 kHz od 5 A do 6 A CMC 0,30 % 10 Hz do 2 kHz od 6 A do 7 A CMC 0,12 % 2 kHz do 10 kHz od 6 A do 7 A CMC 0,29 % 10 Hz do 2 kHz od 7 A do 11 A CMC 0,11 % 2 kHz do 10 kHz od 7 A do 11 A CMC 0,28 % 10 Hz do 2 kHz od 11 A do 20 A CMC 0,10 % 2 kHz do 10 kHz od 11 A do 20 A CMC 0,27 % 50 Hz od 200 mA do 250 mA CMC 0,067 % 50 Hz od 250 mA do 300 mA CMC 0,057 % 50 Hz od 300 mA do 400 mA CMC 0,084 % 50 Hz od 400 mA do 500 mA CMC 0,067 % 50 Hz od 500 mA do 600 mA CMC 0,056 % 50 Hz od 600 mA do 800 mA CMC 0,084 % 50 Hz od 800 mA do 1 A CMC 0,067 % 50 Hz od 1 A do 1,3 A CMC 0,056 % 50 Hz od 1,3 A do 2 A CMC 0,079 % 50 Hz od 2 A do 2,6 A CMC 0,056 % 50 Hz od 2,6 A do 5 A CMC 0,070 % 50 Hz od 5 A do 5,2 A CMC 0,048 % 50 Hz od 5,2 A do 9 A CMC 0,070 % 50 Hz od 9 A do 10 A CMC 0,050 % 50 Hz od 10 A do 1200 A CMC 0,04 % Střídavý proud / Zdroje střídavého proudu Kalibrace – elektrické veličiny Přímé měření multimetrem nebo nepřímé měření pomocí proudového bočníku, proudového transformátoru 10 Hz až 10 kHz 10 µA až 20 µA CMC 30 nA 10 Hz až 10 kHz 20 µA až 30 µA CMC 0,15 % 10 Hz až 10 kHz 30 µA až 40 µA CMC 0,12 % 10 Hz až 10 kHz 40 µA až 50 µA CMC 0,098 % 10 Hz až 10 kHz 50 µA až 60 µA CMC 0,088 % 10 Hz až 10 kHz 60 µA až 70 µA CMC 0,081 % 10 Hz až 10 kHz 70 µA až 80 µA CMC 0,077 % 10 Hz až 10 kHz 80 µA až 90 mA CMC 0,073 % 10 Hz až 10 kHz 90 µA až 100 µA CMC 0,070 % 10 Hz až 10 kHz 100 µA až 110 µA CMC 0,068 % 10 Hz až 10 kHz 110 µA až 130 µA CMC 0,066 % 10 Hz až 10 kHz 130 µA až 150 µA CMC 0,063 % 10 Hz až 10 kHz 150 µA až 180 µA CMC 0,061 % 10 Hz až 10 kHz 180 µA až 200 µA CMC 0,059 % 10 Hz až 10 kHz 200 µA až 250 µA CMC 0,13 % 10 Hz až 10 kHz 250 µA až 300 µA CMC 0,11 % 10 Hz až 10 kHz 300 µA až 400 µA CMC 0,095 % 10 Hz až 10 kHz 400 µA až 500 µA CMC 0,079 % 10 Hz až 10 kHz 500 µA až 600 µA CMC 0,069 % 10 Hz až 10 kHz 600 µA až 700 µA CMC 0,062 % 10 Hz až 10 kHz 700 µA až 800 µA CMC 0,057 % 10 Hz až 10 kHz 800 µA až 900 µA CMC 0,054 % 10 Hz až 10 kHz 900 µA až 1 mA CMC 0,051 % 10 Hz až 10 kHz 1 mA až 1,1 mA CMC 0,049 % 10 Hz až 10 kHz 1,1 mA až 1,2 mA CMC 0,047 % 10 Hz až 10 kHz 1,2 mA až 1,4 mA CMC 0,045 % 10 Hz až 10 kHz 1,4 mA až 1,6 mA CMC 0,043 % 10 Hz až 10 kHz 1,6 mA až 1,9 mA CMC 0,041 % 10 Hz až 10 kHz 1,9 mA až 2 mA CMC 0,039 % 10 Hz až 10 kHz 2 mA až 2,5 mA CMC 0,13 % 10 Hz až 10 kHz 2,5 mA až 3 mA CMC 0,11 % 10 Hz až 10 kHz 3 mA až 4 mA CMC 0,095 % 10 Hz až 10 kHz 4 mA až 5 mA CMC 0,079 % 10 Hz až 10 kHz 5 mA až 6 mA CMC 0,069 % 10 Hz až 10 kHz 6 mA až 7 mA CMC 0,062 % 10 Hz až 10 kHz 7 mA až 8 mA CMC 0,057 % 10 Hz až 10 kHz 8 mA až 9 mA CMC 0,054 % 10 Hz až 10 kHz 9 mA až 10 mA CMC 0,051 % 10 Hz až 10 kHz 10 mA až 11 mA CMC 0,049 % 10 Hz až 10 kHz 11 mA až 12 mA CMC 0,047 % 10 Hz až 10 kHz 12 mA až 14 mA CMC 0,045 % 10 Hz až 10 kHz 14 mA až 16 mA CMC 0,043 % 10 Hz až 10 kHz 16 mA až 19 mA CMC 0,041 % 10 Hz až 10 kHz 19 mA až 20 mA CMC 0,039 % 10 Hz až 10 kHz 20 mA až 25 mA CMC 0,13 % 10 Hz až 10 kHz 25 mA až 30 mA CMC 0,11 % 10 Hz až 10 kHz 30 mA až 40 mA CMC 0,092 % 10 Hz až 10 kHz 40 mA až 50 mA CMC 0,076 % 10 Hz až 10 kHz 50 mA až 60 mA CMC 0,066 % 10 Hz až 10 kHz 60 mA až 70 mA CMC 0,059 % 10 Hz až 10 kHz 70 mA až 80 mA CMC 0,054 % 10 Hz až 10 kHz 80 mA až 90 mA CMC 0,051 % 10 Hz až 10 kHz 90 mA až 100 mA CMC 0,048 % 10 Hz až 10 kHz 100 mA až 110 mA CMC 0,046 % 10 Hz až 10 kHz 110 mA až 120 mA CMC 0,044 % 10 Hz až 10 kHz 120 mA až 140 mA CMC 0,042 % 10 Hz až 10 kHz 140 mA až 160 mA CMC 0,040 % 10 Hz až 10 kHz 160 mA až 190 mA CMC 0,038 % 10 Hz až 10 kHz 190 mA až 200 mA CMC 0,036 % 10 Hz až 2 kHz 200 mA až 250 mA CMC 0,17 % 2 kHz až 10 kHz 200 mA až 250 mA CMC 0,18 % 10 Hz až 2 kHz 250 mA až 300 mA CMC 0,15 % 2 kHz až 10 kHz 250 mA až 300 mA CMC 0,16 % 10 Hz až 2 kHz 300 mA až 400 mA CMC 0,13 % 2 kHz až 10 kHz 300 mA až 400 mA CMC 0,14 % 10 Hz až 2 kHz 400 mA až 500 mA CMC 0,12 % 2 kHz až 10 kHz 400 mA až 500 mA CMC 0,13 % 10 Hz až 2 kHz 500 mA až 600 mA CMC 0,11 % 2 kHz až 10 kHz 500 mA až 600 mA CMC 0,12 % 10 Hz až 2 kHz 600 mA až 700 mA CMC 0,094 % 2 kHz až 10 kHz 600 mA až 700 mA CMC 0,11 % 10 Hz až 2 kHz 700 mA až 800 mA CMC 0,089 % 2 kHz až 10 kHz 700 mA až 800 mA CMC 0,099 % 10 Hz až 2 kHz 800 mA až 900 mA CMC 0,086 % 2 kHz až 10 kHz 800 mA až 900 mA CMC 0,096 % 10 Hz až 2 kHz 900 mA až 1 A CMC 0,083 % 2 kHz až 10 kHz 900 mA až 1 A CMC 0,093 % 10 Hz až 2 kHz 1 A až 1,1 A CMC 0,081 % 2 kHz až 10 kHz 1 A až 1,1 A CMC 0,091 % 10 Hz až 2 kHz 1,1 A až 1,2 A CMC 0,079 % 2 kHz až 10 kHz 1,1 A až 1,2 A CMC 0,089 % 10 Hz až 2 kHz 1,2 A až 1,3 A CMC 0,077 % 2 kHz až 10 kHz 1,2 A až 1,3 A CMC 0,087 % 10 Hz až 2 kHz 1,3 A až 1,4 A CMC 0,076 % 2 kHz až 10 kHz 1,3 A až 1,4 A CMC 0,087 % 10 Hz až 2 kHz 1,4 A až 1,5 A CMC 0,076 % 2 kHz až 10 kHz 1,4 A až 1,5 A CMC 0,085 % 10 Hz až 2 kHz 1,5 A až 1,6 A CMC 0,074 % 2 kHz až 10 kHz 1,5 A až 1,6 A CMC 0,085 % 10 Hz až 2 kHz 1,6 A až 1,7 A CMC 0,074 % 2 kHz až 10 kHz 1,6 A až 1,7 A CMC 0,083 % 10 Hz až 2 kHz 1,7 A až 2 A CMC 0,072 % 2 kHz až 10 kHz 1,7 A až 2 A CMC 0,083 % 10 Hz až 2 kHz 2 A až 2,5 A CMC 0,19 % 2 kHz až 10 kHz 2 A až 2,5 A CMC 0,36 % 10 Hz až 2 kHz 2,5 A až 3 A CMC 0,16 % 2 kHz až 10 kHz 2,5 A až 3 A CMC 0,34 % 10 Hz až 2 kHz 3 A až 4 A CMC 0,15 % 2 kHz až 10 kHz 3 A až 4 A CMC 0,32 % 10 Hz až 2 kHz 4 A až 5 A CMC 0,14 % 2 kHz až 10 kHz 4 A až 5 A CMC 0,31 % 10 Hz až 2 kHz 5 A až 6 A CMC 0,13 % 2 kHz až 10 kHz 5 A až 6 A CMC 0,30 % 10 Hz až 2 kHz 6 A až 7 A CMC 0,12 % 2 kHz až 10 kHz 6 A až 7 A CMC 0,29 % 10 Hz až 2 kHz 7 A až 11 A CMC 0,11 % 2 kHz až 10 kHz 7 A až 11 A CMC 0,28 % 10 Hz až 2 kHz 11 A až 20 A CMC 0,10 % 2 kHz až 10 kHz 11 A až 20 A CMC 0,27 % 50 Hz 200 mA až 250 mA CMC 0,067 % 50 Hz 250 mA až 300 mA CMC 0,057 % 50 Hz 300 mA až 400 mA CMC 0,084 % 50 Hz 400 mA až 500 mA CMC 0,067 % 50 Hz 500 mA až 600 mA CMC 0,056 % 50 Hz 600 mA až 800 mA CMC 0,084 % 50 Hz 800 mA až 1 A CMC 0,067 % 50 Hz 1 A až 1,3 A CMC 0,056 % 50 Hz 1,3 A až 2 A CMC 0,079 % 50 Hz 2 A až 2,6 A CMC 0,056 % 50 Hz 2,6 A až 5 A CMC 0,070 % 50 Hz 5 A až 5,2 A CMC 0,048 % 50 Hz 5,2 A až 9 A CMC 0,070 % 50 Hz 9 A až 10 A CMC 0,050 % 50 Hz 10 A až 1200 A CMC 0,04 % TP4, TP21 Prad przemienny / Zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem lub pomiar posredni za pomoca bocznika pradowego, przekladnika pradowego 10 Hz do 10 kHz od 10 µA do 20 µA CMC 30 nA 10 Hz do 10 kHz od 20 µA do 30 µA CMC 0,15 % 10 Hz do 10 kHz od 30 µA do 40 µA CMC 0,12 % 10 Hz do 10 kHz od 40 µA do 50 µA CMC 0,098 % 10 Hz do 10 kHz od 50 µA do 60 µA CMC 0,088 % 10 Hz do 10 kHz od 60 µA do 70 µA CMC 0,081 % 10 Hz do 10 kHz od 70 µA do 80 µA CMC 0,077 % 10 Hz do 10 kHz od 80 µA do 90 mA CMC 0,073 % 10 Hz do 10 kHz od 90 µA do 100 µA CMC 0,070 % 10 Hz do 10 kHz od 100 µA do 110 µA CMC 0,068 % 10 Hz do 10 kHz od 110 µA do 130 µA CMC 0,066 % 10 Hz do 10 kHz od 130 µA do 150 µA CMC 0,063 % 10 Hz do 10 kHz od 150 µA do 180 µA CMC 0,061 % 10 Hz do 10 kHz od 180 µA do 200 µA CMC 0,059 % 10 Hz do 10 kHz od 200 µA do 250 µA CMC 0,13 % 10 Hz do 10 kHz od 250 µA do 300 µA CMC 0,11 % 10 Hz do 10 kHz od 300 µA do 400 µA CMC 0,095 % 10 Hz do 10 kHz od 400 µA do 500 µA CMC 0,079 % 10 Hz do 10 kHz od 500 µA do 600 µA CMC 0,069 % 10 Hz do 10 kHz od 600 µA do 700 µA CMC 0,062 % 10 Hz do 10 kHz od 700 µA do 800 µA CMC 0,057 % 10 Hz do 10 kHz od 800 µA do 900 µA CMC 0,054 % 10 Hz do 10 kHz od 900 µA do 1 mA CMC 0,051 % 10 Hz do 10 kHz od 1 mA do 1,1 mA CMC 0,049 % 10 Hz do 10 kHz od 1,1 mA do 1,2 mA CMC 0,047 % 10 Hz do 10 kHz od 1,2 mA do 1,4 mA CMC 0,045 % 10 Hz do 10 kHz od 1,4 mA do 1,6 mA CMC 0,043 % 10 Hz do 10 kHz od 1,6 mA do 1,9 mA CMC 0,041 % 10 Hz do 10 kHz od 1,9 mA do 2 mA CMC 0,039 % 10 Hz do 10 kHz od 2 mA do 2,5 mA CMC 0,13 % 10 Hz do 10 kHz od 2,5 mA do 3 mA CMC 0,11 % 10 Hz do 10 kHz od 3 mA do 4 mA CMC 0,095 % 10 Hz do 10 kHz od 4 mA do 5 mA CMC 0,079 % 10 Hz do 10 kHz od 5 mA do 6 mA CMC 0,069 % 10 Hz do 10 kHz od 6 mA do 7 mA CMC 0,062 % 10 Hz do 10 kHz od 7 mA do 8 mA CMC 0,057 % 10 Hz do 10 kHz od 8 mA do 9 mA CMC 0,054 % 10 Hz do 10 kHz od 9 mA do 10 mA CMC 0,051 % 10 Hz do 10 kHz od 10 mA do 11 mA CMC 0,049 % 10 Hz do 10 kHz od 11 mA do 12 mA CMC 0,047 % 10 Hz do 10 kHz od 12 mA do 14 mA CMC 0,045 % 10 Hz do 10 kHz od 14 mA do 16 mA CMC 0,043 % 10 Hz do 10 kHz od 16 mA do 19 mA CMC 0,041 % 10 Hz do 10 kHz od 19 mA do 20 mA CMC 0,039 % 10 Hz do 10 kHz od 20 mA do 25 mA CMC 0,13 % 10 Hz do 10 kHz od 25 mA do 30 mA CMC 0,11 % 10 Hz do 10 kHz od 30 mA do 40 mA CMC 0,092 % 10 Hz do 10 kHz od 40 mA do 50 mA CMC 0,076 % 10 Hz do 10 kHz od 50 mA do 60 mA CMC 0,066 % 10 Hz do 10 kHz od 60 mA do 70 mA CMC 0,059 % 10 Hz do 10 kHz od 70 mA do 80 mA CMC 0,054 % 10 Hz do 10 kHz od 80 mA do 90 mA CMC 0,051 % 10 Hz do 10 kHz od 90 mA do 100 mA CMC 0,048 % 10 Hz do 10 kHz od 100 mA do 110 mA CMC 0,046 % 10 Hz do 10 kHz od 110 mA do 120 mA CMC 0,044 % 10 Hz do 10 kHz od 120 mA do 140 mA CMC 0,042 % 10 Hz do 10 kHz od 140 mA do 160 mA CMC 0,040 % 10 Hz do 10 kHz od 160 mA do 190 mA CMC 0,038 % 10 Hz do 10 kHz od 190 mA do 200 mA CMC 0,036 % 10 Hz do 2 kHz od 200 mA do 250 mA CMC 0,17 % 2 kHz do 10 kHz od 200 mA do 250 mA CMC 0,18 % 10 Hz do 2 kHz od 250 mA do 300 mA CMC 0,15 % 2 kHz do 10 kHz od 250 mA do 300 mA CMC 0,16 % 10 Hz do 2 kHz od 300 mA do 400 mA CMC 0,13 % 2 kHz do 10 kHz od 300 mA do 400 mA CMC 0,14 % 10 Hz do 2 kHz od 400 mA do 500 mA CMC 0,12 % 2 kHz do 10 kHz od 400 mA do 500 mA CMC 0,13 % 10 Hz do 2 kHz od 500 mA do 600 mA CMC 0,11 % 2 kHz do 10 kHz od 500 mA do 600 mA CMC 0,12 % 10 Hz do 2 kHz od 600 mA do 700 mA CMC 0,094 % 2 kHz do 10 kHz od 600 mA do 700 mA CMC 0,11 % 10 Hz do 2 kHz od 700 mA do 800 mA CMC 0,089 % 2 kHz do 10 kHz od 700 mA do 800 mA CMC 0,099 % 10 Hz do 2 kHz od 800 mA do 900 mA CMC 0,086 % 2 kHz do 10 kHz od 800 mA do 900 mA CMC 0,096 % 10 Hz do 2 kHz od 900 mA do 1 A CMC 0,083 % 2 kHz do 10 kHz od 900 mA do 1 A CMC 0,093 % 10 Hz do 2 kHz od 1 A do 1,1 A CMC 0,081 % 2 kHz do 10 kHz od 1 A do 1,1 A CMC 0,091 % 10 Hz do 2 kHz od 1,1 A do 1,2 A CMC 0,079 % 2 kHz do 10 kHz od 1,1 A do 1,2 A CMC 0,089 % 10 Hz do 2 kHz od 1,2 A do 1,3 A CMC 0,077 % 2 kHz do 10 kHz od 1,2 A do 1,3 A CMC 0,087 % 10 Hz do 2 kHz od 1,3 A do 1,4 A CMC 0,076 % 2 kHz do 10 kHz od 1,3 A do 1,4 A CMC 0,087 % 10 Hz do 2 kHz od 1,4 A do 1,5 A CMC 0,076 % 2 kHz do 10 kHz od 1,4 A do 1,5 A CMC 0,085 % 10 Hz do 2 kHz od 1,5 A do 1,6 A CMC 0,074 % 2 kHz do 10 kHz od 1,5 A do 1,6 A CMC 0,085 % 10 Hz do 2 kHz od 1,6 A do 1,7 A CMC 0,074 % 2 kHz do 10 kHz od 1,6 A do 1,7 A CMC 0,083 % 10 Hz do 2 kHz od 1,7 A do 2 A CMC 0,072 % 2 kHz do 10 kHz od 1,7 A do 2 A CMC 0,083 % 10 Hz do 2 kHz od 2 A do 2,5 A CMC 0,19 % 2 kHz do 10 kHz od 2 A do 2,5 A CMC 0,36 % 10 Hz do 2 kHz od 2,5 A do 3 A CMC 0,16 % 2 kHz do 10 kHz od 2,5 A do 3 A CMC 0,34 % 10 Hz do 2 kHz od 3 A do 4 A CMC 0,15 % 2 kHz do 10 kHz od 3 A do 4 A CMC 0,32 % 10 Hz do 2 kHz od 4 A do 5 A CMC 0,14 % 2 kHz do 10 kHz od 4 A do 5 A CMC 0,31 % 10 Hz do 2 kHz od 5 A do 6 A CMC 0,13 % 2 kHz do 10 kHz od 5 A do 6 A CMC 0,30 % 10 Hz do 2 kHz od 6 A do 7 A CMC 0,12 % 2 kHz do 10 kHz od 6 A do 7 A CMC 0,29 % 10 Hz do 2 kHz od 7 A do 11 A CMC 0,11 % 2 kHz do 10 kHz od 7 A do 11 A CMC 0,28 % 10 Hz do 2 kHz od 11 A do 20 A CMC 0,10 % 2 kHz do 10 kHz od 11 A do 20 A CMC 0,27 % 50 Hz od 200 mA do 250 mA CMC 0,067 % 50 Hz od 250 mA do 300 mA CMC 0,057 % 50 Hz od 300 mA do 400 mA CMC 0,084 % 50 Hz od 400 mA do 500 mA CMC 0,067 % 50 Hz od 500 mA do 600 mA CMC 0,056 % 50 Hz od 600 mA do 800 mA CMC 0,084 % 50 Hz od 800 mA do 1 A CMC 0,067 % 50 Hz od 1 A do 1,3 A CMC 0,056 % 50 Hz od 1,3 A do 2 A CMC 0,079 % 50 Hz od 2 A do 2,6 A CMC 0,056 % 50 Hz od 2,6 A do 5 A CMC 0,070 % 50 Hz od 5 A do 5,2 A CMC 0,048 % 50 Hz od 5,2 A do 9 A CMC 0,070 % 50 Hz od 9 A do 10 A CMC 0,050 % 50 Hz od 10 A do 1200 A CMC 0,04 % Stridavy proud / Zdroje stridaveho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem nebo neprime mereni pomoci proudoveho bocniku, proudoveho transformatoru 10 Hz az 10 kHz 10 µA az 20 µA CMC 30 nA 10 Hz az 10 kHz 20 µA az 30 µA CMC 0,15 % 10 Hz az 10 kHz 30 µA az 40 µA CMC 0,12 % 10 Hz az 10 kHz 40 µA az 50 µA CMC 0,098 % 10 Hz az 10 kHz 50 µA az 60 µA CMC 0,088 % 10 Hz az 10 kHz 60 µA az 70 µA CMC 0,081 % 10 Hz az 10 kHz 70 µA az 80 µA CMC 0,077 % 10 Hz az 10 kHz 80 µA az 90 mA CMC 0,073 % 10 Hz az 10 kHz 90 µA az 100 µA CMC 0,070 % 10 Hz az 10 kHz 100 µA az 110 µA CMC 0,068 % 10 Hz az 10 kHz 110 µA az 130 µA CMC 0,066 % 10 Hz az 10 kHz 130 µA az 150 µA CMC 0,063 % 10 Hz az 10 kHz 150 µA az 180 µA CMC 0,061 % 10 Hz az 10 kHz 180 µA az 200 µA CMC 0,059 % 10 Hz az 10 kHz 200 µA az 250 µA CMC 0,13 % 10 Hz az 10 kHz 250 µA az 300 µA CMC 0,11 % 10 Hz az 10 kHz 300 µA az 400 µA CMC 0,095 % 10 Hz az 10 kHz 400 µA az 500 µA CMC 0,079 % 10 Hz az 10 kHz 500 µA az 600 µA CMC 0,069 % 10 Hz az 10 kHz 600 µA az 700 µA CMC 0,062 % 10 Hz az 10 kHz 700 µA az 800 µA CMC 0,057 % 10 Hz az 10 kHz 800 µA az 900 µA CMC 0,054 % 10 Hz az 10 kHz 900 µA az 1 mA CMC 0,051 % 10 Hz az 10 kHz 1 mA az 1,1 mA CMC 0,049 % 10 Hz az 10 kHz 1,1 mA az 1,2 mA CMC 0,047 % 10 Hz az 10 kHz 1,2 mA az 1,4 mA CMC 0,045 % 10 Hz az 10 kHz 1,4 mA az 1,6 mA CMC 0,043 % 10 Hz az 10 kHz 1,6 mA az 1,9 mA CMC 0,041 % 10 Hz az 10 kHz 1,9 mA az 2 mA CMC 0,039 % 10 Hz az 10 kHz 2 mA az 2,5 mA CMC 0,13 % 10 Hz az 10 kHz 2,5 mA az 3 mA CMC 0,11 % 10 Hz az 10 kHz 3 mA az 4 mA CMC 0,095 % 10 Hz az 10 kHz 4 mA az 5 mA CMC 0,079 % 10 Hz az 10 kHz 5 mA az 6 mA CMC 0,069 % 10 Hz az 10 kHz 6 mA az 7 mA CMC 0,062 % 10 Hz az 10 kHz 7 mA az 8 mA CMC 0,057 % 10 Hz az 10 kHz 8 mA az 9 mA CMC 0,054 % 10 Hz az 10 kHz 9 mA az 10 mA CMC 0,051 % 10 Hz az 10 kHz 10 mA az 11 mA CMC 0,049 % 10 Hz az 10 kHz 11 mA az 12 mA CMC 0,047 % 10 Hz az 10 kHz 12 mA az 14 mA CMC 0,045 % 10 Hz az 10 kHz 14 mA az 16 mA CMC 0,043 % 10 Hz az 10 kHz 16 mA az 19 mA CMC 0,041 % 10 Hz az 10 kHz 19 mA az 20 mA CMC 0,039 % 10 Hz az 10 kHz 20 mA az 25 mA CMC 0,13 % 10 Hz az 10 kHz 25 mA az 30 mA CMC 0,11 % 10 Hz az 10 kHz 30 mA az 40 mA CMC 0,092 % 10 Hz az 10 kHz 40 mA az 50 mA CMC 0,076 % 10 Hz az 10 kHz 50 mA az 60 mA CMC 0,066 % 10 Hz az 10 kHz 60 mA az 70 mA CMC 0,059 % 10 Hz az 10 kHz 70 mA az 80 mA CMC 0,054 % 10 Hz az 10 kHz 80 mA az 90 mA CMC 0,051 % 10 Hz az 10 kHz 90 mA az 100 mA CMC 0,048 % 10 Hz az 10 kHz 100 mA az 110 mA CMC 0,046 % 10 Hz az 10 kHz 110 mA az 120 mA CMC 0,044 % 10 Hz az 10 kHz 120 mA az 140 mA CMC 0,042 % 10 Hz az 10 kHz 140 mA az 160 mA CMC 0,040 % 10 Hz az 10 kHz 160 mA az 190 mA CMC 0,038 % 10 Hz az 10 kHz 190 mA az 200 mA CMC 0,036 % 10 Hz az 2 kHz 200 mA az 250 mA CMC 0,17 % 2 kHz az 10 kHz 200 mA az 250 mA CMC 0,18 % 10 Hz az 2 kHz 250 mA az 300 mA CMC 0,15 % 2 kHz az 10 kHz 250 mA az 300 mA CMC 0,16 % 10 Hz az 2 kHz 300 mA az 400 mA CMC 0,13 % 2 kHz az 10 kHz 300 mA az 400 mA CMC 0,14 % 10 Hz az 2 kHz 400 mA az 500 mA CMC 0,12 % 2 kHz az 10 kHz 400 mA az 500 mA CMC 0,13 % 10 Hz az 2 kHz 500 mA az 600 mA CMC 0,11 % 2 kHz az 10 kHz 500 mA az 600 mA CMC 0,12 % 10 Hz az 2 kHz 600 mA az 700 mA CMC 0,094 % 2 kHz az 10 kHz 600 mA az 700 mA CMC 0,11 % 10 Hz az 2 kHz 700 mA az 800 mA CMC 0,089 % 2 kHz az 10 kHz 700 mA az 800 mA CMC 0,099 % 10 Hz az 2 kHz 800 mA az 900 mA CMC 0,086 % 2 kHz az 10 kHz 800 mA az 900 mA CMC 0,096 % 10 Hz az 2 kHz 900 mA az 1 A CMC 0,083 % 2 kHz az 10 kHz 900 mA az 1 A CMC 0,093 % 10 Hz az 2 kHz 1 A az 1,1 A CMC 0,081 % 2 kHz az 10 kHz 1 A az 1,1 A CMC 0,091 % 10 Hz az 2 kHz 1,1 A az 1,2 A CMC 0,079 % 2 kHz az 10 kHz 1,1 A az 1,2 A CMC 0,089 % 10 Hz az 2 kHz 1,2 A az 1,3 A CMC 0,077 % 2 kHz az 10 kHz 1,2 A az 1,3 A CMC 0,087 % 10 Hz az 2 kHz 1,3 A az 1,4 A CMC 0,076 % 2 kHz az 10 kHz 1,3 A az 1,4 A CMC 0,087 % 10 Hz az 2 kHz 1,4 A az 1,5 A CMC 0,076 % 2 kHz az 10 kHz 1,4 A az 1,5 A CMC 0,085 % 10 Hz az 2 kHz 1,5 A az 1,6 A CMC 0,074 % 2 kHz az 10 kHz 1,5 A az 1,6 A CMC 0,085 % 10 Hz az 2 kHz 1,6 A az 1,7 A CMC 0,074 % 2 kHz az 10 kHz 1,6 A az 1,7 A CMC 0,083 % 10 Hz az 2 kHz 1,7 A az 2 A CMC 0,072 % 2 kHz az 10 kHz 1,7 A az 2 A CMC 0,083 % 10 Hz az 2 kHz 2 A az 2,5 A CMC 0,19 % 2 kHz az 10 kHz 2 A az 2,5 A CMC 0,36 % 10 Hz az 2 kHz 2,5 A az 3 A CMC 0,16 % 2 kHz az 10 kHz 2,5 A az 3 A CMC 0,34 % 10 Hz az 2 kHz 3 A az 4 A CMC 0,15 % 2 kHz az 10 kHz 3 A az 4 A CMC 0,32 % 10 Hz az 2 kHz 4 A az 5 A CMC 0,14 % 2 kHz az 10 kHz 4 A az 5 A CMC 0,31 % 10 Hz az 2 kHz 5 A az 6 A CMC 0,13 % 2 kHz az 10 kHz 5 A az 6 A CMC 0,30 % 10 Hz az 2 kHz 6 A az 7 A CMC 0,12 % 2 kHz az 10 kHz 6 A az 7 A CMC 0,29 % 10 Hz az 2 kHz 7 A az 11 A CMC 0,11 % 2 kHz az 10 kHz 7 A az 11 A CMC 0,28 % 10 Hz az 2 kHz 11 A az 20 A CMC 0,10 % 2 kHz az 10 kHz 11 A az 20 A CMC 0,27 % 50 Hz 200 mA az 250 mA CMC 0,067 % 50 Hz 250 mA az 300 mA CMC 0,057 % 50 Hz 300 mA az 400 mA CMC 0,084 % 50 Hz 400 mA az 500 mA CMC 0,067 % 50 Hz 500 mA az 600 mA CMC 0,056 % 50 Hz 600 mA az 800 mA CMC 0,084 % 50 Hz 800 mA az 1 A CMC 0,067 % 50 Hz 1 A az 1,3 A CMC 0,056 % 50 Hz 1,3 A az 2 A CMC 0,079 % 50 Hz 2 A az 2,6 A CMC 0,056 % 50 Hz 2,6 A az 5 A CMC 0,070 % 50 Hz 5 A az 5,2 A CMC 0,048 % 50 Hz 5,2 A az 9 A CMC 0,070 % 50 Hz 9 A az 10 A CMC 0,050 % 50 Hz 10 A az 1200 A CMC 0,04 % TP4, TP21","search_en":"AC current / AC current sources Calibration – electrical quantities Direct measurement with a multimeter or indirect measurement with a current shunt, current transformer 10 Hz to 10 kHz 10 µA to 20 µA CMC 30 nA 10 Hz to 10 kHz 20 µA to 30 µA CMC 0,15 % 10 Hz to 10 kHz 30 µA to 40 µA CMC 0,12 % 10 Hz to 10 kHz 40 µA to 50 µA CMC 0,098 % 10 Hz to 10 kHz 50 µA to 60 µA CMC 0,088 % 10 Hz to 10 kHz 60 µA to 70 µA CMC 0,081 % 10 Hz to 10 kHz 70 µA to 80 µA CMC 0,077 % 10 Hz to 10 kHz 80 µA to 90 mA CMC 0,073 % 10 Hz to 10 kHz 90 µA to 100 µA CMC 0,070 % 10 Hz to 10 kHz 100 µA to 110 µA CMC 0,068 % 10 Hz to 10 kHz 110 µA to 130 µA CMC 0,066 % 10 Hz to 10 kHz 130 µA to 150 µA CMC 0,063 % 10 Hz to 10 kHz 150 µA to 180 µA CMC 0,061 % 10 Hz to 10 kHz 180 µA to 200 µA CMC 0,059 % 10 Hz to 10 kHz 200 µA to 250 µA CMC 0,13 % 10 Hz to 10 kHz 250 µA to 300 µA CMC 0,11 % 10 Hz to 10 kHz 300 µA to 400 µA CMC 0,095 % 10 Hz to 10 kHz 400 µA to 500 µA CMC 0,079 % 10 Hz to 10 kHz 500 µA to 600 µA CMC 0,069 % 10 Hz to 10 kHz 600 µA to 700 µA CMC 0,062 % 10 Hz to 10 kHz 700 µA to 800 µA CMC 0,057 % 10 Hz to 10 kHz 800 µA to 900 µA CMC 0,054 % 10 Hz to 10 kHz 900 µA to 1 mA CMC 0,051 % 10 Hz to 10 kHz 1 mA to 1,1 mA CMC 0,049 % 10 Hz to 10 kHz 1,1 mA to 1,2 mA CMC 0,047 % 10 Hz to 10 kHz 1,2 mA to 1,4 mA CMC 0,045 % 10 Hz to 10 kHz 1,4 mA to 1,6 mA CMC 0,043 % 10 Hz to 10 kHz 1,6 mA to 1,9 mA CMC 0,041 % 10 Hz to 10 kHz 1,9 mA to 2 mA CMC 0,039 % 10 Hz to 10 kHz 2 mA to 2,5 mA CMC 0,13 % 10 Hz to 10 kHz 2,5 mA to 3 mA CMC 0,11 % 10 Hz to 10 kHz 3 mA to 4 mA CMC 0,095 % 10 Hz to 10 kHz 4 mA to 5 mA CMC 0,079 % 10 Hz to 10 kHz 5 mA to 6 mA CMC 0,069 % 10 Hz to 10 kHz 6 mA to 7 mA CMC 0,062 % 10 Hz to 10 kHz 7 mA to 8 mA CMC 0,057 % 10 Hz to 10 kHz 8 mA to 9 mA CMC 0,054 % 10 Hz to 10 kHz 9 mA to 10 mA CMC 0,051 % 10 Hz to 10 kHz 10 mA to 11 mA CMC 0,049 % 10 Hz to 10 kHz 11 mA to 12 mA CMC 0,047 % 10 Hz to 10 kHz 12 mA to 14 mA CMC 0,045 % 10 Hz to 10 kHz 14 mA to 16 mA CMC 0,043 % 10 Hz to 10 kHz 16 mA to 19 mA CMC 0,041 % 10 Hz to 10 kHz 19 mA to 20 mA CMC 0,039 % 10 Hz to 10 kHz 20 mA to 25 mA CMC 0,13 % 10 Hz to 10 kHz 25 mA to 30 mA CMC 0,11 % 10 Hz to 10 kHz 30 mA to 40 mA CMC 0,092 % 10 Hz to 10 kHz 40 mA to 50 mA CMC 0,076 % 10 Hz to 10 kHz 50 mA to 60 mA CMC 0,066 % 10 Hz to 10 kHz 60 mA to 70 mA CMC 0,059 % 10 Hz to 10 kHz 70 mA to 80 mA CMC 0,054 % 10 Hz to 10 kHz 80 mA to 90 mA CMC 0,051 % 10 Hz to 10 kHz 90 mA to 100 mA CMC 0,048 % 10 Hz to 10 kHz 100 mA to 110 mA CMC 0,046 % 10 Hz to 10 kHz 110 mA to 120 mA CMC 0,044 % 10 Hz to 10 kHz 120 mA to 140 mA CMC 0,042 % 10 Hz to 10 kHz 140 mA to 160 mA CMC 0,040 % 10 Hz to 10 kHz 160 mA to 190 mA CMC 0,038 % 10 Hz to 10 kHz 190 mA to 200 mA CMC 0,036 % 10 Hz to 2 kHz 200 mA to 250 mA CMC 0,17 % 2 kHz to 10 kHz 200 mA to 250 mA CMC 0,18 % 10 Hz to 2 kHz 250 mA to 300 mA CMC 0,15 % 2 kHz to 10 kHz 250 mA to 300 mA CMC 0,16 % 10 Hz to 2 kHz 300 mA to 400 mA CMC 0,13 % 2 kHz to 10 kHz 300 mA to 400 mA CMC 0,14 % 10 Hz to 2 kHz 400 mA to 500 mA CMC 0,12 % 2 kHz to 10 kHz 400 mA to 500 mA CMC 0,13 % 10 Hz to 2 kHz 500 mA to 600 mA CMC 0,11 % 2 kHz to 10 kHz 500 mA to 600 mA CMC 0,12 % 10 Hz to 2 kHz 600 mA to 700 mA CMC 0,094 % 2 kHz to 10 kHz 600 mA to 700 mA CMC 0,11 % 10 Hz to 2 kHz 700 mA to 800 mA CMC 0,089 % 2 kHz to 10 kHz 700 mA to 800 mA CMC 0,099 % 10 Hz to 2 kHz 800 mA to 900 mA CMC 0,086 % 2 kHz to 10 kHz 800 mA to 900 mA CMC 0,096 % 10 Hz to 2 kHz 900 mA to 1 A CMC 0,083 % 2 kHz to 10 kHz 900 mA to 1 A CMC 0,093 % 10 Hz to 2 kHz 1 A to 1,1 A CMC 0,081 % 2 kHz to 10 kHz 1 A to 1,1 A CMC 0,091 % 10 Hz to 2 kHz 1,1 A to 1,2 A CMC 0,079 % 2 kHz to 10 kHz 1,1 A to 1,2 A CMC 0,089 % 10 Hz to 2 kHz 1,2 A to 1,3 A CMC 0,077 % 2 kHz to 10 kHz 1,2 A to 1,3 A CMC 0,087 % 10 Hz to 2 kHz 1,3 A to 1,4 A CMC 0,076 % 2 kHz to 10 kHz 1,3 A to 1,4 A CMC 0,087 % 10 Hz to 2 kHz 1,4 A to 1,5 A CMC 0,076 % 2 kHz to 10 kHz 1,4 A to 1,5 A CMC 0,085 % 10 Hz to 2 kHz 1,5 A to 1,6 A CMC 0,074 % 2 kHz to 10 kHz 1,5 A to 1,6 A CMC 0,085 % 10 Hz to 2 kHz 1,6 A to 1,7 A CMC 0,074 % 2 kHz to 10 kHz 1,6 A to 1,7 A CMC 0,083 % 10 Hz to 2 kHz 1,7 A to 2 A CMC 0,072 % 2 kHz to 10 kHz 1,7 A to 2 A CMC 0,083 % 10 Hz to 2 kHz 2 A to 2,5 A CMC 0,19 % 2 kHz to 10 kHz 2 A to 2,5 A CMC 0,36 % 10 Hz to 2 kHz 2,5 A to 3 A CMC 0,16 % 2 kHz to 10 kHz 2,5 A to 3 A CMC 0,34 % 10 Hz to 2 kHz 3 A to 4 A CMC 0,15 % 2 kHz to 10 kHz 3 A to 4 A CMC 0,32 % 10 Hz to 2 kHz 4 A to 5 A CMC 0,14 % 2 kHz to 10 kHz 4 A to 5 A CMC 0,31 % 10 Hz to 2 kHz 5 A to 6 A CMC 0,13 % 2 kHz to 10 kHz 5 A to 6 A CMC 0,30 % 10 Hz to 2 kHz 6 A to 7 A CMC 0,12 % 2 kHz to 10 kHz 6 A to 7 A CMC 0,29 % 10 Hz to 2 kHz 7 A to 11 A CMC 0,11 % 2 kHz to 10 kHz 7 A to 11 A CMC 0,28 % 10 Hz to 2 kHz 11 A to 20 A CMC 0,10 % 2 kHz to 10 kHz 11 A to 20 A CMC 0,27 % 50 Hz 200 mA to 250 mA CMC 0,067 % 50 Hz 250 mA to 300 mA CMC 0,057 % 50 Hz 300 mA to 400 mA CMC 0,084 % 50 Hz 400 mA to 500 mA CMC 0,067 % 50 Hz 500 mA to 600 mA CMC 0,056 % 50 Hz 600 mA to 800 mA CMC 0,084 % 50 Hz 800 mA to 1 A CMC 0,067 % 50 Hz 1 A to 1,3 A CMC 0,056 % 50 Hz 1,3 A to 2 A CMC 0,079 % 50 Hz 2 A to 2,6 A CMC 0,056 % 50 Hz 2,6 A to 5 A CMC 0,070 % 50 Hz 5 A to 5,2 A CMC 0,048 % 50 Hz 5,2 A to 9 A CMC 0,070 % 50 Hz 9 A to 10 A CMC 0,050 % 50 Hz 10 A to 1200 A CMC 0,04 % TP4, TP21","search_zh":"交流电流 / 交流电流源 校准 – 电学量 用万用表直接测量或借助电流分流器、电流互感器间接测量 10 Hz 至 10 kHz 10 µA 至 20 µA CMC 30 nA 10 Hz 至 10 kHz 20 µA 至 30 µA CMC 0,15 % 10 Hz 至 10 kHz 30 µA 至 40 µA CMC 0,12 % 10 Hz 至 10 kHz 40 µA 至 50 µA CMC 0,098 % 10 Hz 至 10 kHz 50 µA 至 60 µA CMC 0,088 % 10 Hz 至 10 kHz 60 µA 至 70 µA CMC 0,081 % 10 Hz 至 10 kHz 70 µA 至 80 µA CMC 0,077 % 10 Hz 至 10 kHz 80 µA 至 90 mA CMC 0,073 % 10 Hz 至 10 kHz 90 µA 至 100 µA CMC 0,070 % 10 Hz 至 10 kHz 100 µA 至 110 µA CMC 0,068 % 10 Hz 至 10 kHz 110 µA 至 130 µA CMC 0,066 % 10 Hz 至 10 kHz 130 µA 至 150 µA CMC 0,063 % 10 Hz 至 10 kHz 150 µA 至 180 µA CMC 0,061 % 10 Hz 至 10 kHz 180 µA 至 200 µA CMC 0,059 % 10 Hz 至 10 kHz 200 µA 至 250 µA CMC 0,13 % 10 Hz 至 10 kHz 250 µA 至 300 µA CMC 0,11 % 10 Hz 至 10 kHz 300 µA 至 400 µA CMC 0,095 % 10 Hz 至 10 kHz 400 µA 至 500 µA CMC 0,079 % 10 Hz 至 10 kHz 500 µA 至 600 µA CMC 0,069 % 10 Hz 至 10 kHz 600 µA 至 700 µA CMC 0,062 % 10 Hz 至 10 kHz 700 µA 至 800 µA CMC 0,057 % 10 Hz 至 10 kHz 800 µA 至 900 µA CMC 0,054 % 10 Hz 至 10 kHz 900 µA 至 1 mA CMC 0,051 % 10 Hz 至 10 kHz 1 mA 至 1,1 mA CMC 0,049 % 10 Hz 至 10 kHz 1,1 mA 至 1,2 mA CMC 0,047 % 10 Hz 至 10 kHz 1,2 mA 至 1,4 mA CMC 0,045 % 10 Hz 至 10 kHz 1,4 mA 至 1,6 mA CMC 0,043 % 10 Hz 至 10 kHz 1,6 mA 至 1,9 mA CMC 0,041 % 10 Hz 至 10 kHz 1,9 mA 至 2 mA CMC 0,039 % 10 Hz 至 10 kHz 2 mA 至 2,5 mA CMC 0,13 % 10 Hz 至 10 kHz 2,5 mA 至 3 mA CMC 0,11 % 10 Hz 至 10 kHz 3 mA 至 4 mA CMC 0,095 % 10 Hz 至 10 kHz 4 mA 至 5 mA CMC 0,079 % 10 Hz 至 10 kHz 5 mA 至 6 mA CMC 0,069 % 10 Hz 至 10 kHz 6 mA 至 7 mA CMC 0,062 % 10 Hz 至 10 kHz 7 mA 至 8 mA CMC 0,057 % 10 Hz 至 10 kHz 8 mA 至 9 mA CMC 0,054 % 10 Hz 至 10 kHz 9 mA 至 10 mA CMC 0,051 % 10 Hz 至 10 kHz 10 mA 至 11 mA CMC 0,049 % 10 Hz 至 10 kHz 11 mA 至 12 mA CMC 0,047 % 10 Hz 至 10 kHz 12 mA 至 14 mA CMC 0,045 % 10 Hz 至 10 kHz 14 mA 至 16 mA CMC 0,043 % 10 Hz 至 10 kHz 16 mA 至 19 mA CMC 0,041 % 10 Hz 至 10 kHz 19 mA 至 20 mA CMC 0,039 % 10 Hz 至 10 kHz 20 mA 至 25 mA CMC 0,13 % 10 Hz 至 10 kHz 25 mA 至 30 mA CMC 0,11 % 10 Hz 至 10 kHz 30 mA 至 40 mA CMC 0,092 % 10 Hz 至 10 kHz 40 mA 至 50 mA CMC 0,076 % 10 Hz 至 10 kHz 50 mA 至 60 mA CMC 0,066 % 10 Hz 至 10 kHz 60 mA 至 70 mA CMC 0,059 % 10 Hz 至 10 kHz 70 mA 至 80 mA CMC 0,054 % 10 Hz 至 10 kHz 80 mA 至 90 mA CMC 0,051 % 10 Hz 至 10 kHz 90 mA 至 100 mA CMC 0,048 % 10 Hz 至 10 kHz 100 mA 至 110 mA CMC 0,046 % 10 Hz 至 10 kHz 110 mA 至 120 mA CMC 0,044 % 10 Hz 至 10 kHz 120 mA 至 140 mA CMC 0,042 % 10 Hz 至 10 kHz 140 mA 至 160 mA CMC 0,040 % 10 Hz 至 10 kHz 160 mA 至 190 mA CMC 0,038 % 10 Hz 至 10 kHz 190 mA 至 200 mA CMC 0,036 % 10 Hz 至 2 kHz 200 mA 至 250 mA CMC 0,17 % 2 kHz 至 10 kHz 200 mA 至 250 mA CMC 0,18 % 10 Hz 至 2 kHz 250 mA 至 300 mA CMC 0,15 % 2 kHz 至 10 kHz 250 mA 至 300 mA CMC 0,16 % 10 Hz 至 2 kHz 300 mA 至 400 mA CMC 0,13 % 2 kHz 至 10 kHz 300 mA 至 400 mA CMC 0,14 % 10 Hz 至 2 kHz 400 mA 至 500 mA CMC 0,12 % 2 kHz 至 10 kHz 400 mA 至 500 mA CMC 0,13 % 10 Hz 至 2 kHz 500 mA 至 600 mA CMC 0,11 % 2 kHz 至 10 kHz 500 mA 至 600 mA CMC 0,12 % 10 Hz 至 2 kHz 600 mA 至 700 mA CMC 0,094 % 2 kHz 至 10 kHz 600 mA 至 700 mA CMC 0,11 % 10 Hz 至 2 kHz 700 mA 至 800 mA CMC 0,089 % 2 kHz 至 10 kHz 700 mA 至 800 mA CMC 0,099 % 10 Hz 至 2 kHz 800 mA 至 900 mA CMC 0,086 % 2 kHz 至 10 kHz 800 mA 至 900 mA CMC 0,096 % 10 Hz 至 2 kHz 900 mA 至 1 A CMC 0,083 % 2 kHz 至 10 kHz 900 mA 至 1 A CMC 0,093 % 10 Hz 至 2 kHz 1 A 至 1,1 A CMC 0,081 % 2 kHz 至 10 kHz 1 A 至 1,1 A CMC 0,091 % 10 Hz 至 2 kHz 1,1 A 至 1,2 A CMC 0,079 % 2 kHz 至 10 kHz 1,1 A 至 1,2 A CMC 0,089 % 10 Hz 至 2 kHz 1,2 A 至 1,3 A CMC 0,077 % 2 kHz 至 10 kHz 1,2 A 至 1,3 A CMC 0,087 % 10 Hz 至 2 kHz 1,3 A 至 1,4 A CMC 0,076 % 2 kHz 至 10 kHz 1,3 A 至 1,4 A CMC 0,087 % 10 Hz 至 2 kHz 1,4 A 至 1,5 A CMC 0,076 % 2 kHz 至 10 kHz 1,4 A 至 1,5 A CMC 0,085 % 10 Hz 至 2 kHz 1,5 A 至 1,6 A CMC 0,074 % 2 kHz 至 10 kHz 1,5 A 至 1,6 A CMC 0,085 % 10 Hz 至 2 kHz 1,6 A 至 1,7 A CMC 0,074 % 2 kHz 至 10 kHz 1,6 A 至 1,7 A CMC 0,083 % 10 Hz 至 2 kHz 1,7 A 至 2 A CMC 0,072 % 2 kHz 至 10 kHz 1,7 A 至 2 A CMC 0,083 % 10 Hz 至 2 kHz 2 A 至 2,5 A CMC 0,19 % 2 kHz 至 10 kHz 2 A 至 2,5 A CMC 0,36 % 10 Hz 至 2 kHz 2,5 A 至 3 A CMC 0,16 % 2 kHz 至 10 kHz 2,5 A 至 3 A CMC 0,34 % 10 Hz 至 2 kHz 3 A 至 4 A CMC 0,15 % 2 kHz 至 10 kHz 3 A 至 4 A CMC 0,32 % 10 Hz 至 2 kHz 4 A 至 5 A CMC 0,14 % 2 kHz 至 10 kHz 4 A 至 5 A CMC 0,31 % 10 Hz 至 2 kHz 5 A 至 6 A CMC 0,13 % 2 kHz 至 10 kHz 5 A 至 6 A CMC 0,30 % 10 Hz 至 2 kHz 6 A 至 7 A CMC 0,12 % 2 kHz 至 10 kHz 6 A 至 7 A CMC 0,29 % 10 Hz 至 2 kHz 7 A 至 11 A CMC 0,11 % 2 kHz 至 10 kHz 7 A 至 11 A CMC 0,28 % 10 Hz 至 2 kHz 11 A 至 20 A CMC 0,10 % 2 kHz 至 10 kHz 11 A 至 20 A CMC 0,27 % 50 Hz 200 mA 至 250 mA CMC 0,067 % 50 Hz 250 mA 至 300 mA CMC 0,057 % 50 Hz 300 mA 至 400 mA CMC 0,084 % 50 Hz 400 mA 至 500 mA CMC 0,067 % 50 Hz 500 mA 至 600 mA CMC 0,056 % 50 Hz 600 mA 至 800 mA CMC 0,084 % 50 Hz 800 mA 至 1 A CMC 0,067 % 50 Hz 1 A 至 1,3 A CMC 0,056 % 50 Hz 1,3 A 至 2 A CMC 0,079 % 50 Hz 2 A 至 2,6 A CMC 0,056 % 50 Hz 2,6 A 至 5 A CMC 0,070 % 50 Hz 5 A 至 5,2 A CMC 0,048 % 50 Hz 5,2 A 至 9 A CMC 0,070 % 50 Hz 9 A 至 10 A CMC 0,050 % 50 Hz 10 A 至 1200 A CMC 0,04 % TP4, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"01dec37d549a6d29e676d42d","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / Mierniki prądu przemiennego","test_object_en":"AC current / AC current meters","test_object_zh":"交流电流 / 交流电流测量仪器","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 20 Hz","range":"od 10 µA do 20 µA","cmc":"40 nA"},{"name":"20 Hz do 40 Hz","range":"od 10 µA do 20 µA","cmc":"28 nA"},{"name":"40 Hz do 1 kHz","range":"od 10 µA do 20 µA","cmc":"18 nA"},{"name":"1 kHz do 5 kHz","range":"od 10 µA do 20 µA","cmc":"47 nA"},{"name":"5 kHz do 10 kHz","range":"od 10 µA do 20 µA","cmc":"97 nA"},{"name":"10 Hz do 20 Hz","range":"od 20 µA do 30 µA","cmc":"0,20 %"},{"name":"20 Hz do 40 Hz","range":"od 20 µA do 30 µA","cmc":"0,14 %"},{"name":"40 Hz do 1 kHz","range":"od 20 µA do 30 µA","cmc":"0,095 %"},{"name":"1 kHz do 5 kHz","range":"od 20 µA do 30 µA","cmc":"0,26 %"},{"name":"5 kHz do 10 kHz","range":"od 20 µA do 30 µA","cmc":"0,57 %"},{"name":"10 Hz do 20 Hz","range":"od 30 µA do 40 µA","cmc":"0,16 %"},{"name":"20 Hz do 40 Hz","range":"od 30 µA do 40 µA","cmc":"0,11 %"},{"name":"40 Hz do 1 kHz","range":"od 30 µA do 40 µA","cmc":"0,069 %"},{"name":"1 kHz do 5 kHz","range":"od 30 µA do 40 µA","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 30 µA do 40 µA","cmc":"0,43 %"},{"name":"10 Hz do 20 Hz","range":"od 40 µA do 50 µA","cmc":"0,14 %"},{"name":"20 Hz do 40 Hz","range":"od 40 µA do 50 µA","cmc":"0,086 %"},{"name":"40 Hz do 1 kHz","range":"od 40 µA do 50 µA","cmc":"0,055 %"},{"name":"1 kHz do 5 kHz","range":"od 40 µA do 50 µA","cmc":"0,17 %"},{"name":"5 kHz do 10 kHz","range":"od 40 µA do 50 µA","cmc":"0,37 %"},{"name":"10 Hz do 20 Hz","range":"od 50 µA do 60 µA","cmc":"0,13 %"},{"name":"20 Hz do 40 Hz","range":"od 50 µA do 60 µA","cmc":"0,076 %"},{"name":"40 Hz do 1 kHz","range":"od 50 µA do 60 µA","cmc":"0,048 %"},{"name":"1 kHz do 5 kHz","range":"od 50 µA do 60 µA","cmc":"0,15 %"},{"name":"5 kHz do 10 kHz","range":"od 50 µA do 60 µA","cmc":"0,33 %"},{"name":"10 Hz do 20 Hz","range":"od 60 µA do 80 µA","cmc":"0,12 %"},{"name":"20 Hz do 40 Hz","range":"od 60 µA do 80 µA","cmc":"0,070 %"},{"name":"40 Hz do 1 kHz","range":"od 60 µA do 80 µA","cmc":"0,042 %"},{"name":"1 kHz do 5 kHz","range":"od 60 µA do 80 µA","cmc":"0,13 %"},{"name":"5 kHz do 10 kHz","range":"od 60 µA do 80 µA","cmc":"0,30 %"},{"name":"10 Hz do 20 Hz","range":"od 80 µA do 100 µA","cmc":"0,099 %"},{"name":"20 Hz do 40 Hz","range":"od 80 µA do 100 µA","cmc":"0,061 %"},{"name":"40 Hz do 1 kHz","range":"od 80 µA do 100 µA","cmc":"0,036 %"},{"name":"1 kHz do 5 kHz","range":"od 80 µA do 100 µA","cmc":"0,12 %"},{"name":"5 kHz do 10 kHz","range":"od 80 µA do 100 µA","cmc":"0,27 %"},{"name":"10 Hz do 20 Hz","range":"od 100 µA do 130 µA","cmc":"0,096 %"},{"name":"20 Hz do 40 Hz","range":"od 100 µA do 130 µA","cmc":"0,056 %"},{"name":"40 Hz do 1 kHz","range":"od 100 µA do 130 µA","cmc":"0,032 %"},{"name":"1 kHz do 5 kHz","range":"od 100 µA do 130 µA","cmc":"0,11 %"},{"name":"5 kHz do 10 kHz","range":"od 100 µA do 130 µA","cmc":"0,25 %"},{"name":"10 Hz do 20 Hz","range":"od 130 µA do 180 µA","cmc":"0,090 %"},{"name":"20 Hz do 40 Hz","range":"od 130 µA do 180 µA","cmc":"0,052 %"},{"name":"40 Hz do 1 kHz","range":"od 130 µA do 180 µA","cmc":"0,029 %"},{"name":"1 kHz do 5 kHz","range":"od 130 µA do 180 µA","cmc":"0,092 %"},{"name":"5 kHz do 10 kHz","range":"od 130 µA do 180 µA","cmc":"0,23 %"},{"name":"10 Hz do 20 Hz","range":"od 180 µA do 220 µA","cmc":"0,085 %"},{"name":"20 Hz do 40 Hz","range":"od 180 µA do 220 µA","cmc":"0,048 %"},{"name":"40 Hz do 1 kHz","range":"od 180 µA do 220 µA","cmc":"0,025 %"},{"name":"1 kHz do 5 kHz","range":"od 180 µA do 220 µA","cmc":"0,084 %"},{"name":"5 kHz do 10 kHz","range":"od 180 µA do 220 µA","cmc":"0,21 %"},{"name":"10 Hz do 20 Hz","range":"od 220 µA do 300 µA","cmc":"0,089 %"},{"name":"20 Hz do 40 Hz","range":"od 220 µA do 300 µA","cmc":"0,052 %"},{"name":"40 Hz do 1 kHz","range":"od 220 µA do 300 µA","cmc":"0,032 %"},{"name":"1 kHz do 5 kHz","range":"od 220 µA do 300 µA","cmc":"0,25 %"},{"name":"5 kHz do 10 kHz","range":"od 220 µA do 300 µA","cmc":"0,53 %"},{"name":"10 Hz do 20 Hz","range":"od 300 µA do 400 µA","cmc":"0,084 %"},{"name":"20 Hz do 40 Hz","range":"od 300 µA do 400 µA","cmc":"0,048 %"},{"name":"40 Hz do 1 kHz","range":"od 300 µA do 400 µA","cmc":"0,028 %"},{"name":"1 kHz do 5 kHz","range":"od 300 µA do 400 µA","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 300 µA do 400 µA","cmc":"0,43 %"},{"name":"10 Hz do 20 Hz","range":"od 400 µA do 500 µA","cmc":"0,081 %"},{"name":"20 Hz do 40 Hz","range":"od 400 µA do 500 µA","cmc":"0,045 %"},{"name":"40 Hz do 1 kHz","range":"od 400 µA do 500 µA","cmc":"0,025 %"},{"name":"1 kHz do 5 kHz","range":"od 400 µA do 500 µA","cmc":"0,17 %"},{"name":"5 kHz do 10 kHz","range":"od 400 µA do 500 µA","cmc":"0,37 %"},{"name":"10 Hz do 20 Hz","range":"od 500 µA do 600 µA","cmc":"0,079 %"},{"name":"20 Hz do 40 Hz","range":"od 500 µA do 600 µA","cmc":"0,044 %"},{"name":"40 Hz do 1 kHz","range":"od 500 µA do 600 µA","cmc":"0,023 %"},{"name":"1 kHz do 5 kHz","range":"od 500 µA do 600 µA","cmc":"0,15 %"},{"name":"5 kHz do 10 kHz","range":"od 500 µA do 600 µA","cmc":"0,33 %"},{"name":"10 Hz do 20 Hz","range":"od 600 µA do 800 µA","cmc":"0,078 %"},{"name":"20 Hz do 40 Hz","range":"od 600 µA do 800 µA","cmc":"0,043 %"},{"name":"40 Hz do 1 kHz","range":"od 600 µA do 800 µA","cmc":"0,022 %"},{"name":"1 kHz do 5 kHz","range":"od 600 µA do 800 µA","cmc":"0,13 %"},{"name":"5 kHz do 10 kHz","range":"od 600 µA do 800 µA","cmc":"0,30 %"},{"name":"10 Hz do 20 Hz","range":"od 800 µA do 1 mA","cmc":"0,076 %"},{"name":"20 Hz do 40 Hz","range":"od 800 µA do 1 mA","cmc":"0,041 %"},{"name":"40 Hz do 1 kHz","range":"od 800 µA do 1 mA","cmc":"0,021 %"},{"name":"1 kHz do 5 kHz","range":"od 800 µA do 1 mA","cmc":"0,12 %"},{"name":"5 kHz do 10 kHz","range":"od 800 µA do 1 mA","cmc":"0,27 %"},{"name":"10 Hz do 20 Hz","range":"od 1 mA do 1,3 mA","cmc":"0,075 %"},{"name":"20 Hz do 40 Hz","range":"od 1 mA do 1,3 mA","cmc":"0,040 %"},{"name":"40 Hz do 1 kHz","range":"od 1 mA do 1,3 mA","cmc":"0,020 %"},{"name":"1 kHz do 5 kHz","range":"od 1 mA do 1,3 mA","cmc":"0,11 %"},{"name":"5 kHz do 10 kHz","range":"od 1 mA do 1,3 mA","cmc":"0,25 %"},{"name":"10 Hz do 20 Hz","range":"od 1,3 mA do 1,8 mA","cmc":"0,074 %"},{"name":"20 Hz do 40 Hz","range":"od 1,3 mA do 1,8 mA","cmc":"0,039 %"},{"name":"40 Hz do 1 kHz","range":"od 1,3 mA do 1,8 mA","cmc":"0,019 %"},{"name":"1 kHz do 5 kHz","range":"od 1,3 mA do 1,8 mA","cmc":"0,092 %"},{"name":"5 kHz do 10 kHz","range":"od 1,3 mA do 1,8 mA","cmc":"0,23 %"},{"name":"10 Hz do 20 Hz","range":"od 1,8 mA do 2,2 mA","cmc":"0,073 %"},{"name":"20 Hz do 40 Hz","range":"od 1,8 mA do 2,2 mA","cmc":"0,074 %"},{"name":"40 Hz do 1 kHz","range":"od 1,8 mA do 2,2 mA","cmc":"0,019 %"},{"name":"1 kHz do 5 kHz","range":"od 1,8 mA do 2,2 mA","cmc":"0,084 %"},{"name":"5 kHz do 10 kHz","range":"od 1,8 mA do 2,2 mA","cmc":"0,21 %"},{"name":"10 Hz do 20 Hz","range":"od 2,2 mA do 3 mA","cmc":"0,089 %"},{"name":"20 Hz do 40 Hz","range":"od 2,2 mA do 3 mA","cmc":"0,052 %"},{"name":"40 Hz do 1 kHz","range":"od 2,2 mA do 3 mA","cmc":"0,032 %"},{"name":"1 kHz do 5 kHz","range":"od 2,2 mA do 3 mA","cmc":"0,25 %"},{"name":"5 kHz do 10 kHz","range":"od 2,2 mA do 3 mA","cmc":"0,53 %"},{"name":"10 Hz do 20 Hz","range":"od 3 mA do 4 mA","cmc":"0,084 %"},{"name":"20 Hz do 40 Hz","range":"od 3 mA do 4 mA","cmc":"0,048 %"},{"name":"40 Hz do 1 kHz","range":"od 3 mA do 4 mA","cmc":"0,028 %"},{"name":"1 kHz do 5 kHz","range":"od 3 mA do 4 mA","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 3 mA do 4 mA","cmc":"0,43 %"},{"name":"10 Hz do 20 Hz","range":"od 4 mA do 5 mA","cmc":"0,081 %"},{"name":"20 Hz do 40 Hz","range":"od 4 mA do 5 mA","cmc":"0,045 %"},{"name":"40 Hz do 1 kHz","range":"od 4 mA do 5 mA","cmc":"0,025 %"},{"name":"1 kHz do 5 kHz","range":"od 4 mA do 5 mA","cmc":"0,17 %"},{"name":"5 kHz do 10 kHz","range":"od 4 mA do 5 mA","cmc":"0,37 %"},{"name":"10 Hz do 20 Hz","range":"od 5 mA do 6 mA","cmc":"0,079 %"},{"name":"20 Hz do 40 Hz","range":"od 5 mA do 6 mA","cmc":"0,043 %"},{"name":"40 Hz do 1 kHz","range":"od 5 mA do 6 mA","cmc":"0,023 %"},{"name":"1 kHz do 5 kHz","range":"od 5 mA do 6 mA","cmc":"0,15 %"},{"name":"5 kHz do 10 kHz","range":"od 5 mA do 6 mA","cmc":"0,33 %"},{"name":"10 Hz do 20 Hz","range":"od 6 mA do 8 mA","cmc":"0,078 %"},{"name":"20 Hz do 40 Hz","range":"od 6 mA do 8 mA","cmc":"0,042 %"},{"name":"40 Hz do 1 kHz","range":"od 6 mA do 8 mA","cmc":"0,022 %"},{"name":"1 kHz do 5 kHz","range":"od 6 mA do 8 mA","cmc":"0,13 %"},{"name":"5 kHz do 10 kHz","range":"od 6 mA do 8 mA","cmc":"0,30 %"},{"name":"10 Hz do 20 Hz","range":"od 8 mA do 10 mA","cmc":"0,076 %"},{"name":"20 Hz do 40 Hz","range":"od 8 mA do 10 mA","cmc":"0,041 %"},{"name":"40 Hz do 1 kHz","range":"od 8 mA do 10 mA","cmc":"0,021 %"},{"name":"1 kHz do 5 kHz","range":"od 8 mA do 10 mA","cmc":"0,12 %"},{"name":"5 kHz do 10 kHz","range":"od 8 mA do 10 mA","cmc":"0,27 %"},{"name":"10 Hz do 20 Hz","range":"od 10 mA do 13 mA","cmc":"0,075 %"},{"name":"20 Hz do 40 Hz","range":"od 10 mA do 13 mA","cmc":"0,040 %"},{"name":"40 Hz do 1 kHz","range":"od 10 mA do 13 mA","cmc":"0,020 %"},{"name":"1 kHz do 5 kHz","range":"od 10 mA do 13 mA","cmc":"0,11 %"},{"name":"5 kHz do 10 kHz","range":"od 10 mA do 13 mA","cmc":"0,25 %"},{"name":"10 Hz do 20 Hz","range":"od 13 mA do 18 mA","cmc":"0,074 %"},{"name":"20 Hz do 40 Hz","range":"od 13 mA do 18 mA","cmc":"0,039 %"},{"name":"40 Hz do 1 kHz","range":"od 13 mA do 18 mA","cmc":"0,019 %"},{"name":"1 kHz do 5 kHz","range":"od 13 mA do 18 mA","cmc":"0,092 %"},{"name":"5 kHz do 10 kHz","range":"od 13 mA do 18 mA","cmc":"0,23 %"},{"name":"10 Hz do 20 Hz","range":"od 18 mA do 22 mA","cmc":"0,073 %"},{"name":"20 Hz do 40 Hz","range":"od 18 mA do 22 mA","cmc":"0,039 %"},{"name":"40 Hz do 1 kHz","range":"od 18 mA do 22 mA","cmc":"0,019 %"},{"name":"1 kHz do 5 kHz","range":"od 18 mA do 22 mA","cmc":"0,084 %"},{"name":"5 kHz do 10 kHz","range":"od 18 mA do 22 mA","cmc":"0,21 %"},{"name":"10 Hz do 20 Hz","range":"od 22 mA do 30 mA","cmc":"0,089 %"},{"name":"20 Hz do 40 Hz","range":"od 22 mA do 30 mA","cmc":"0,052 %"},{"name":"40 Hz do 1 kHz","range":"od 22 mA do 30 mA","cmc":"0,032 %"},{"name":"1 kHz do 5 kHz","range":"od 22 mA do 30 mA","cmc":"0,25 %"},{"name":"5 kHz do 10 kHz","range":"od 22 mA do 30 mA","cmc":"0,53 %"},{"name":"10 Hz do 20 Hz","range":"od 30 mA do 40 mA","cmc":"0,084 %"},{"name":"20 Hz do 40 Hz","range":"od 30 mA do 40 mA","cmc":"0,048 %"},{"name":"40 Hz do 1 kHz","range":"od 30 mA do 40 mA","cmc":"0,028 %"},{"name":"1 kHz do 5 kHz","range":"od 30 mA do 40 mA","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 30 mA do 40 mA","cmc":"0,43 %"},{"name":"10 Hz do 20 Hz","range":"od 40 mA do 50 mA","cmc":"0,081 %"},{"name":"20 Hz do 40 Hz","range":"od 40 mA do 50 mA","cmc":"0,045 %"},{"name":"40 Hz do 1 kHz","range":"od 40 mA do 50 mA","cmc":"0,025 %"},{"name":"1 kHz do 5 kHz","range":"od 40 mA do 50 mA","cmc":"0,17 %"},{"name":"5 kHz do 10 kHz","range":"od 40 mA do 50 mA","cmc":"0,37 %"},{"name":"10 Hz do 20 Hz","range":"od 50 mA do 60 mA","cmc":"0,079 %"},{"name":"20 Hz do 40 Hz","range":"od 50 mA do 60 mA","cmc":"0,043 %"},{"name":"40 Hz do 1 kHz","range":"od 50 mA do 60 mA","cmc":"0,023 %"},{"name":"1 kHz do 5 kHz","range":"od 50 mA do 60 mA","cmc":"0,15 %"},{"name":"5 kHz do 10 kHz","range":"od 50 mA do 60 mA","cmc":"0,33 %"},{"name":"10 Hz do 20 Hz","range":"od 60 mA do 80 mA","cmc":"0,078 %"},{"name":"20 Hz do 40 Hz","range":"od 60 mA do 80 mA","cmc":"0,042 %"},{"name":"40 Hz do 1 kHz","range":"od 60 mA do 80 mA","cmc":"0,022 %"},{"name":"1 kHz do 5 kHz","range":"od 60 mA do 80 mA","cmc":"0,13 %"},{"name":"5 kHz do 10 kHz","range":"od 60 mA do 80 mA","cmc":"0,30 %"},{"name":"10 Hz do 20 Hz","range":"od 80 mA do 100 mA","cmc":"0,076 %"},{"name":"20 Hz do 40 Hz","range":"od 80 mA do 100 mA","cmc":"0,041 %"},{"name":"40 Hz do 1 kHz","range":"od 80 mA do 100 mA","cmc":"0,021 %"},{"name":"1 kHz do 5 kHz","range":"od 80 mA do 100 mA","cmc":"0,12 %"},{"name":"5 kHz do 10 kHz","range":"od 80 mA do 100 mA","cmc":"0,27 %"},{"name":"10 Hz do 20 Hz","range":"od 100 mA do 130 mA","cmc":"0,075 %"},{"name":"20 Hz do 40 Hz","range":"od 100 mA do 130 mA","cmc":"0,040 %"},{"name":"40 Hz do 1 kHz","range":"od 100 mA do 130 mA","cmc":"0,020 %"},{"name":"1 kHz do 5 kHz","range":"od 100 mA do 130 mA","cmc":"0,11 %"},{"name":"5 kHz do 10 kHz","range":"od 100 mA do 130 mA","cmc":"0,25 %"},{"name":"10 Hz do 20 Hz","range":"od 130 mA do 180 mA","cmc":"0,074 %"},{"name":"20 Hz do 40 Hz","range":"od 130 mA do 180 mA","cmc":"0,039 %"},{"name":"40 Hz do 1 kHz","range":"od 130 mA do 180 mA","cmc":"0,019 %"},{"name":"1 kHz do 5 kHz","range":"od 130 mA do 180 mA","cmc":"0,092 %"},{"name":"5 kHz do 10 kHz","range":"od 130 mA do 180 mA","cmc":"0,24 %"},{"name":"10 Hz do 20 Hz","range":"od 180 mA do 220 mA","cmc":"0,073 %"},{"name":"20 Hz do 40 Hz","range":"od 180 mA do 220 mA","cmc":"0,038 %"},{"name":"40 Hz do 1 kHz","range":"od 180 mA do 220 mA","cmc":"0,019 %"},{"name":"1 kHz do 5 kHz","range":"od 180 mA do 220 mA","cmc":"0,084 %"},{"name":"5 kHz do 10 kHz","range":"od 180 mA do 220 mA","cmc":"0,21 %"},{"name":"20 Hz do 1 kHz","range":"od 220 mA do 300 mA","cmc":"0,082 %"},{"name":"1 kHz do 5 kHz","range":"od 220 mA do 300 mA","cmc":"0,12 %"},{"name":"5 kHz do 10 kHz","range":"od 220 mA do 300 mA","cmc":"0,93 %"},{"name":"20 Hz do 1 kHz","range":"od 300 mA do 400 mA","cmc":"0,078 %"},{"name":"1 kHz do 5 kHz","range":"od 300 mA do 400 mA","cmc":"0,11 %"},{"name":"5 kHz do 10 kHz","range":"od 300 mA do 400 mA","cmc":"0,91 %"},{"name":"20 Hz do 1 kHz","range":"od 400 mA do 500 mA","cmc":"0,075 %"},{"name":"1 kHz do 5 kHz","range":"od 400 mA do 500 mA","cmc":"0,098 %"},{"name":"5 kHz do 10 kHz","range":"od 400 mA do 500 mA","cmc":"0,90 %"},{"name":"20 Hz do 1 kHz","range":"od 500 mA do 600 mA","cmc":"0,074 %"},{"name":"1 kHz do 5 kHz","range":"od 500 mA do 600 mA","cmc":"0,094 %"},{"name":"5 kHz do 10 kHz","range":"od 500 mA do 600 mA","cmc":"0,89 %"},{"name":"20 Hz do 1 kHz","range":"od 600 mA do 1 A","cmc":"0,072 %"},{"name":"1 kHz do 5 kHz","range":"od 600 mA do 1 A","cmc":"0,092 %"},{"name":"5 kHz do 10 kHz","range":"od 600 mA do 1 A","cmc":"0,89 %"},{"name":"20 Hz do 1 kHz","range":"od 1 A do 2,2 A","cmc":"0,070 %"},{"name":"1 kHz do 5 kHz","range":"od 1 A do 2,2 A","cmc":"0,086 %"},{"name":"5 kHz do 10 kHz","range":"od 1 A do 2,2 A","cmc":"0,88 %"},{"name":"10 Hz do 1 kHz","range":"od 2,2 A do 3 A","cmc":"0,16 %"},{"name":"1 kHz do 5 kHz","range":"od 2,2 A do 3 A","cmc":"0,22 %"},{"name":"5 kHz do 10 kHz","range":"od 2,2 A do 3 A","cmc":"0,60 %"},{"name":"10 Hz do 1 kHz","range":"od 3 A do 5 A","cmc":"0,14 %"},{"name":"1 kHz do 5 kHz","range":"od 3 A do 5 A","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 3 A do 5 A","cmc":"0,51 %"},{"name":"10 Hz do 1 kHz","range":"od 5 A do 11 A","cmc":"0,13 %"},{"name":"1 kHz do 5 kHz","range":"od 5 A do 11 A","cmc":"0,18 %"},{"name":"5 kHz do 10 kHz","range":"od 5 A do 11 A","cmc":"0,42 %"},{"name":"30 Hz do 45 Hz","range":"od 11 A do 15 A","cmc":"0,23 %"},{"name":"45 Hz do 100 Hz","range":"od 11 A do 15 A","cmc":"0,12 %"},{"name":"100 Hz do 1 kHz","range":"od 11 A do 15 A","cmc":"0,52 %"},{"name":"30 Hz do 45 Hz","range":"od 15 A do 25 A","cmc":"0,22 %"},{"name":"45 Hz do 100 Hz","range":"od 15 A do 25 A","cmc":"0,12 %"},{"name":"100 Hz do 1 kHz","range":"od 15 A do 25 A","cmc":"0,51 %"},{"name":"30 Hz do 45 Hz","range":"od 25 A do 30 A","cmc":"0,21 %"},{"name":"45 Hz do 100 Hz","range":"od 25 A do 30 A","cmc":"0,11 %"},{"name":"100 Hz do 1 kHz","range":"od 25 A do 30 A","cmc":"0,49 %"},{"name":"50 Hz","range":"od 2,2 A do 3 A","cmc":"0,12 %"},{"name":"50 Hz","range":"od 3 A do 4 A","cmc":"0,095 %"},{"name":"50 Hz","range":"od 4 A do 5 A","cmc":"0,084 %"},{"name":"50 Hz","range":"od 5 A do 6 A","cmc":"0,077 %"},{"name":"50 Hz","range":"od 6 A do 7 A","cmc":"0,073 %"},{"name":"50 Hz","range":"od 7 A do 8 A","cmc":"0,070 %"},{"name":"50 Hz","range":"od 8 A do 10 A","cmc":"0,067 %"},{"name":"50 Hz","range":"od 10 A do 11 A","cmc":"0,064 %"},{"name":"50 Hz","range":"od 11 A do 15 A","cmc":"0,10 %"},{"name":"50 Hz","range":"od 15 A do 20 A","cmc":"0,081 %"},{"name":"50 Hz","range":"od 20 A do 90 A","cmc":"0,090 %"}],"parameters_en":[{"name":"10 Hz to 20 Hz","range":"10 µA to 20 µA","cmc":"40 nA"},{"name":"20 Hz to 40 Hz","range":"10 µA to 20 µA","cmc":"28 nA"},{"name":"40 Hz to 1 kHz","range":"10 µA to 20 µA","cmc":"18 nA"},{"name":"1 kHz to 5 kHz","range":"10 µA to 20 µA","cmc":"47 nA"},{"name":"5 kHz to 10 kHz","range":"10 µA to 20 µA","cmc":"97 nA"},{"name":"10 Hz to 20 Hz","range":"20 µA to 30 µA","cmc":"0,20 %"},{"name":"20 Hz to 40 Hz","range":"20 µA to 30 µA","cmc":"0,14 %"},{"name":"40 Hz to 1 kHz","range":"20 µA to 30 µA","cmc":"0,095 %"},{"name":"1 kHz to 5 kHz","range":"20 µA to 30 µA","cmc":"0,26 %"},{"name":"5 kHz to 10 kHz","range":"20 µA to 30 µA","cmc":"0,57 %"},{"name":"10 Hz to 20 Hz","range":"30 µA to 40 µA","cmc":"0,16 %"},{"name":"20 Hz to 40 Hz","range":"30 µA to 40 µA","cmc":"0,11 %"},{"name":"40 Hz to 1 kHz","range":"30 µA to 40 µA","cmc":"0,069 %"},{"name":"1 kHz to 5 kHz","range":"30 µA to 40 µA","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"30 µA to 40 µA","cmc":"0,43 %"},{"name":"10 Hz to 20 Hz","range":"40 µA to 50 µA","cmc":"0,14 %"},{"name":"20 Hz to 40 Hz","range":"40 µA to 50 µA","cmc":"0,086 %"},{"name":"40 Hz to 1 kHz","range":"40 µA to 50 µA","cmc":"0,055 %"},{"name":"1 kHz to 5 kHz","range":"40 µA to 50 µA","cmc":"0,17 %"},{"name":"5 kHz to 10 kHz","range":"40 µA to 50 µA","cmc":"0,37 %"},{"name":"10 Hz to 20 Hz","range":"50 µA to 60 µA","cmc":"0,13 %"},{"name":"20 Hz to 40 Hz","range":"50 µA to 60 µA","cmc":"0,076 %"},{"name":"40 Hz to 1 kHz","range":"50 µA to 60 µA","cmc":"0,048 %"},{"name":"1 kHz to 5 kHz","range":"50 µA to 60 µA","cmc":"0,15 %"},{"name":"5 kHz to 10 kHz","range":"50 µA to 60 µA","cmc":"0,33 %"},{"name":"10 Hz to 20 Hz","range":"60 µA to 80 µA","cmc":"0,12 %"},{"name":"20 Hz to 40 Hz","range":"60 µA to 80 µA","cmc":"0,070 %"},{"name":"40 Hz to 1 kHz","range":"60 µA to 80 µA","cmc":"0,042 %"},{"name":"1 kHz to 5 kHz","range":"60 µA to 80 µA","cmc":"0,13 %"},{"name":"5 kHz to 10 kHz","range":"60 µA to 80 µA","cmc":"0,30 %"},{"name":"10 Hz to 20 Hz","range":"80 µA to 100 µA","cmc":"0,099 %"},{"name":"20 Hz to 40 Hz","range":"80 µA to 100 µA","cmc":"0,061 %"},{"name":"40 Hz to 1 kHz","range":"80 µA to 100 µA","cmc":"0,036 %"},{"name":"1 kHz to 5 kHz","range":"80 µA to 100 µA","cmc":"0,12 %"},{"name":"5 kHz to 10 kHz","range":"80 µA to 100 µA","cmc":"0,27 %"},{"name":"10 Hz to 20 Hz","range":"100 µA to 130 µA","cmc":"0,096 %"},{"name":"20 Hz to 40 Hz","range":"100 µA to 130 µA","cmc":"0,056 %"},{"name":"40 Hz to 1 kHz","range":"100 µA to 130 µA","cmc":"0,032 %"},{"name":"1 kHz to 5 kHz","range":"100 µA to 130 µA","cmc":"0,11 %"},{"name":"5 kHz to 10 kHz","range":"100 µA to 130 µA","cmc":"0,25 %"},{"name":"10 Hz to 20 Hz","range":"130 µA to 180 µA","cmc":"0,090 %"},{"name":"20 Hz to 40 Hz","range":"130 µA to 180 µA","cmc":"0,052 %"},{"name":"40 Hz to 1 kHz","range":"130 µA to 180 µA","cmc":"0,029 %"},{"name":"1 kHz to 5 kHz","range":"130 µA to 180 µA","cmc":"0,092 %"},{"name":"5 kHz to 10 kHz","range":"130 µA to 180 µA","cmc":"0,23 %"},{"name":"10 Hz to 20 Hz","range":"180 µA to 220 µA","cmc":"0,085 %"},{"name":"20 Hz to 40 Hz","range":"180 µA to 220 µA","cmc":"0,048 %"},{"name":"40 Hz to 1 kHz","range":"180 µA to 220 µA","cmc":"0,025 %"},{"name":"1 kHz to 5 kHz","range":"180 µA to 220 µA","cmc":"0,084 %"},{"name":"5 kHz to 10 kHz","range":"180 µA to 220 µA","cmc":"0,21 %"},{"name":"10 Hz to 20 Hz","range":"220 µA to 300 µA","cmc":"0,089 %"},{"name":"20 Hz to 40 Hz","range":"220 µA to 300 µA","cmc":"0,052 %"},{"name":"40 Hz to 1 kHz","range":"220 µA to 300 µA","cmc":"0,032 %"},{"name":"1 kHz to 5 kHz","range":"220 µA to 300 µA","cmc":"0,25 %"},{"name":"5 kHz to 10 kHz","range":"220 µA to 300 µA","cmc":"0,53 %"},{"name":"10 Hz to 20 Hz","range":"300 µA to 400 µA","cmc":"0,084 %"},{"name":"20 Hz to 40 Hz","range":"300 µA to 400 µA","cmc":"0,048 %"},{"name":"40 Hz to 1 kHz","range":"300 µA to 400 µA","cmc":"0,028 %"},{"name":"1 kHz to 5 kHz","range":"300 µA to 400 µA","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"300 µA to 400 µA","cmc":"0,43 %"},{"name":"10 Hz to 20 Hz","range":"400 µA to 500 µA","cmc":"0,081 %"},{"name":"20 Hz to 40 Hz","range":"400 µA to 500 µA","cmc":"0,045 %"},{"name":"40 Hz to 1 kHz","range":"400 µA to 500 µA","cmc":"0,025 %"},{"name":"1 kHz to 5 kHz","range":"400 µA to 500 µA","cmc":"0,17 %"},{"name":"5 kHz to 10 kHz","range":"400 µA to 500 µA","cmc":"0,37 %"},{"name":"10 Hz to 20 Hz","range":"500 µA to 600 µA","cmc":"0,079 %"},{"name":"20 Hz to 40 Hz","range":"500 µA to 600 µA","cmc":"0,044 %"},{"name":"40 Hz to 1 kHz","range":"500 µA to 600 µA","cmc":"0,023 %"},{"name":"1 kHz to 5 kHz","range":"500 µA to 600 µA","cmc":"0,15 %"},{"name":"5 kHz to 10 kHz","range":"500 µA to 600 µA","cmc":"0,33 %"},{"name":"10 Hz to 20 Hz","range":"600 µA to 800 µA","cmc":"0,078 %"},{"name":"20 Hz to 40 Hz","range":"600 µA to 800 µA","cmc":"0,043 %"},{"name":"40 Hz to 1 kHz","range":"600 µA to 800 µA","cmc":"0,022 %"},{"name":"1 kHz to 5 kHz","range":"600 µA to 800 µA","cmc":"0,13 %"},{"name":"5 kHz to 10 kHz","range":"600 µA to 800 µA","cmc":"0,30 %"},{"name":"10 Hz to 20 Hz","range":"800 µA to 1 mA","cmc":"0,076 %"},{"name":"20 Hz to 40 Hz","range":"800 µA to 1 mA","cmc":"0,041 %"},{"name":"40 Hz to 1 kHz","range":"800 µA to 1 mA","cmc":"0,021 %"},{"name":"1 kHz to 5 kHz","range":"800 µA to 1 mA","cmc":"0,12 %"},{"name":"5 kHz to 10 kHz","range":"800 µA to 1 mA","cmc":"0,27 %"},{"name":"10 Hz to 20 Hz","range":"1 mA to 1,3 mA","cmc":"0,075 %"},{"name":"20 Hz to 40 Hz","range":"1 mA to 1,3 mA","cmc":"0,040 %"},{"name":"40 Hz to 1 kHz","range":"1 mA to 1,3 mA","cmc":"0,020 %"},{"name":"1 kHz to 5 kHz","range":"1 mA to 1,3 mA","cmc":"0,11 %"},{"name":"5 kHz to 10 kHz","range":"1 mA to 1,3 mA","cmc":"0,25 %"},{"name":"10 Hz to 20 Hz","range":"1,3 mA to 1,8 mA","cmc":"0,074 %"},{"name":"20 Hz to 40 Hz","range":"1,3 mA to 1,8 mA","cmc":"0,039 %"},{"name":"40 Hz to 1 kHz","range":"1,3 mA to 1,8 mA","cmc":"0,019 %"},{"name":"1 kHz to 5 kHz","range":"1,3 mA to 1,8 mA","cmc":"0,092 %"},{"name":"5 kHz to 10 kHz","range":"1,3 mA to 1,8 mA","cmc":"0,23 %"},{"name":"10 Hz to 20 Hz","range":"1,8 mA to 2,2 mA","cmc":"0,073 %"},{"name":"20 Hz to 40 Hz","range":"1,8 mA to 2,2 mA","cmc":"0,074 %"},{"name":"40 Hz to 1 kHz","range":"1,8 mA to 2,2 mA","cmc":"0,019 %"},{"name":"1 kHz to 5 kHz","range":"1,8 mA to 2,2 mA","cmc":"0,084 %"},{"name":"5 kHz to 10 kHz","range":"1,8 mA to 2,2 mA","cmc":"0,21 %"},{"name":"10 Hz to 20 Hz","range":"2,2 mA to 3 mA","cmc":"0,089 %"},{"name":"20 Hz to 40 Hz","range":"2,2 mA to 3 mA","cmc":"0,052 %"},{"name":"40 Hz to 1 kHz","range":"2,2 mA to 3 mA","cmc":"0,032 %"},{"name":"1 kHz to 5 kHz","range":"2,2 mA to 3 mA","cmc":"0,25 %"},{"name":"5 kHz to 10 kHz","range":"2,2 mA to 3 mA","cmc":"0,53 %"},{"name":"10 Hz to 20 Hz","range":"3 mA to 4 mA","cmc":"0,084 %"},{"name":"20 Hz to 40 Hz","range":"3 mA to 4 mA","cmc":"0,048 %"},{"name":"40 Hz to 1 kHz","range":"3 mA to 4 mA","cmc":"0,028 %"},{"name":"1 kHz to 5 kHz","range":"3 mA to 4 mA","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"3 mA to 4 mA","cmc":"0,43 %"},{"name":"10 Hz to 20 Hz","range":"4 mA to 5 mA","cmc":"0,081 %"},{"name":"20 Hz to 40 Hz","range":"4 mA to 5 mA","cmc":"0,045 %"},{"name":"40 Hz to 1 kHz","range":"4 mA to 5 mA","cmc":"0,025 %"},{"name":"1 kHz to 5 kHz","range":"4 mA to 5 mA","cmc":"0,17 %"},{"name":"5 kHz to 10 kHz","range":"4 mA to 5 mA","cmc":"0,37 %"},{"name":"10 Hz to 20 Hz","range":"5 mA to 6 mA","cmc":"0,079 %"},{"name":"20 Hz to 40 Hz","range":"5 mA to 6 mA","cmc":"0,043 %"},{"name":"40 Hz to 1 kHz","range":"5 mA to 6 mA","cmc":"0,023 %"},{"name":"1 kHz to 5 kHz","range":"5 mA to 6 mA","cmc":"0,15 %"},{"name":"5 kHz to 10 kHz","range":"5 mA to 6 mA","cmc":"0,33 %"},{"name":"10 Hz to 20 Hz","range":"6 mA to 8 mA","cmc":"0,078 %"},{"name":"20 Hz to 40 Hz","range":"6 mA to 8 mA","cmc":"0,042 %"},{"name":"40 Hz to 1 kHz","range":"6 mA to 8 mA","cmc":"0,022 %"},{"name":"1 kHz to 5 kHz","range":"6 mA to 8 mA","cmc":"0,13 %"},{"name":"5 kHz to 10 kHz","range":"6 mA to 8 mA","cmc":"0,30 %"},{"name":"10 Hz to 20 Hz","range":"8 mA to 10 mA","cmc":"0,076 %"},{"name":"20 Hz to 40 Hz","range":"8 mA to 10 mA","cmc":"0,041 %"},{"name":"40 Hz to 1 kHz","range":"8 mA to 10 mA","cmc":"0,021 %"},{"name":"1 kHz to 5 kHz","range":"8 mA to 10 mA","cmc":"0,12 %"},{"name":"5 kHz to 10 kHz","range":"8 mA to 10 mA","cmc":"0,27 %"},{"name":"10 Hz to 20 Hz","range":"10 mA to 13 mA","cmc":"0,075 %"},{"name":"20 Hz to 40 Hz","range":"10 mA to 13 mA","cmc":"0,040 %"},{"name":"40 Hz to 1 kHz","range":"10 mA to 13 mA","cmc":"0,020 %"},{"name":"1 kHz to 5 kHz","range":"10 mA to 13 mA","cmc":"0,11 %"},{"name":"5 kHz to 10 kHz","range":"10 mA to 13 mA","cmc":"0,25 %"},{"name":"10 Hz to 20 Hz","range":"13 mA to 18 mA","cmc":"0,074 %"},{"name":"20 Hz to 40 Hz","range":"13 mA to 18 mA","cmc":"0,039 %"},{"name":"40 Hz to 1 kHz","range":"13 mA to 18 mA","cmc":"0,019 %"},{"name":"1 kHz to 5 kHz","range":"13 mA to 18 mA","cmc":"0,092 %"},{"name":"5 kHz to 10 kHz","range":"13 mA to 18 mA","cmc":"0,23 %"},{"name":"10 Hz to 20 Hz","range":"18 mA to 22 mA","cmc":"0,073 %"},{"name":"20 Hz to 40 Hz","range":"18 mA to 22 mA","cmc":"0,039 %"},{"name":"40 Hz to 1 kHz","range":"18 mA to 22 mA","cmc":"0,019 %"},{"name":"1 kHz to 5 kHz","range":"18 mA to 22 mA","cmc":"0,084 %"},{"name":"5 kHz to 10 kHz","range":"18 mA to 22 mA","cmc":"0,21 %"},{"name":"10 Hz to 20 Hz","range":"22 mA to 30 mA","cmc":"0,089 %"},{"name":"20 Hz to 40 Hz","range":"22 mA to 30 mA","cmc":"0,052 %"},{"name":"40 Hz to 1 kHz","range":"22 mA to 30 mA","cmc":"0,032 %"},{"name":"1 kHz to 5 kHz","range":"22 mA to 30 mA","cmc":"0,25 %"},{"name":"5 kHz to 10 kHz","range":"22 mA to 30 mA","cmc":"0,53 %"},{"name":"10 Hz to 20 Hz","range":"30 mA to 40 mA","cmc":"0,084 %"},{"name":"20 Hz to 40 Hz","range":"30 mA to 40 mA","cmc":"0,048 %"},{"name":"40 Hz to 1 kHz","range":"30 mA to 40 mA","cmc":"0,028 %"},{"name":"1 kHz to 5 kHz","range":"30 mA to 40 mA","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"30 mA to 40 mA","cmc":"0,43 %"},{"name":"10 Hz to 20 Hz","range":"40 mA to 50 mA","cmc":"0,081 %"},{"name":"20 Hz to 40 Hz","range":"40 mA to 50 mA","cmc":"0,045 %"},{"name":"40 Hz to 1 kHz","range":"40 mA to 50 mA","cmc":"0,025 %"},{"name":"1 kHz to 5 kHz","range":"40 mA to 50 mA","cmc":"0,17 %"},{"name":"5 kHz to 10 kHz","range":"40 mA to 50 mA","cmc":"0,37 %"},{"name":"10 Hz to 20 Hz","range":"50 mA to 60 mA","cmc":"0,079 %"},{"name":"20 Hz to 40 Hz","range":"50 mA to 60 mA","cmc":"0,043 %"},{"name":"40 Hz to 1 kHz","range":"50 mA to 60 mA","cmc":"0,023 %"},{"name":"1 kHz to 5 kHz","range":"50 mA to 60 mA","cmc":"0,15 %"},{"name":"5 kHz to 10 kHz","range":"50 mA to 60 mA","cmc":"0,33 %"},{"name":"10 Hz to 20 Hz","range":"60 mA to 80 mA","cmc":"0,078 %"},{"name":"20 Hz to 40 Hz","range":"60 mA to 80 mA","cmc":"0,042 %"},{"name":"40 Hz to 1 kHz","range":"60 mA to 80 mA","cmc":"0,022 %"},{"name":"1 kHz to 5 kHz","range":"60 mA to 80 mA","cmc":"0,13 %"},{"name":"5 kHz to 10 kHz","range":"60 mA to 80 mA","cmc":"0,30 %"},{"name":"10 Hz to 20 Hz","range":"80 mA to 100 mA","cmc":"0,076 %"},{"name":"20 Hz to 40 Hz","range":"80 mA to 100 mA","cmc":"0,041 %"},{"name":"40 Hz to 1 kHz","range":"80 mA to 100 mA","cmc":"0,021 %"},{"name":"1 kHz to 5 kHz","range":"80 mA to 100 mA","cmc":"0,12 %"},{"name":"5 kHz to 10 kHz","range":"80 mA to 100 mA","cmc":"0,27 %"},{"name":"10 Hz to 20 Hz","range":"100 mA to 130 mA","cmc":"0,075 %"},{"name":"20 Hz to 40 Hz","range":"100 mA to 130 mA","cmc":"0,040 %"},{"name":"40 Hz to 1 kHz","range":"100 mA to 130 mA","cmc":"0,020 %"},{"name":"1 kHz to 5 kHz","range":"100 mA to 130 mA","cmc":"0,11 %"},{"name":"5 kHz to 10 kHz","range":"100 mA to 130 mA","cmc":"0,25 %"},{"name":"10 Hz to 20 Hz","range":"130 mA to 180 mA","cmc":"0,074 %"},{"name":"20 Hz to 40 Hz","range":"130 mA to 180 mA","cmc":"0,039 %"},{"name":"40 Hz to 1 kHz","range":"130 mA to 180 mA","cmc":"0,019 %"},{"name":"1 kHz to 5 kHz","range":"130 mA to 180 mA","cmc":"0,092 %"},{"name":"5 kHz to 10 kHz","range":"130 mA to 180 mA","cmc":"0,24 %"},{"name":"10 Hz to 20 Hz","range":"180 mA to 220 mA","cmc":"0,073 %"},{"name":"20 Hz to 40 Hz","range":"180 mA to 220 mA","cmc":"0,038 %"},{"name":"40 Hz to 1 kHz","range":"180 mA to 220 mA","cmc":"0,019 %"},{"name":"1 kHz to 5 kHz","range":"180 mA to 220 mA","cmc":"0,084 %"},{"name":"5 kHz to 10 kHz","range":"180 mA to 220 mA","cmc":"0,21 %"},{"name":"20 Hz to 1 kHz","range":"220 mA to 300 mA","cmc":"0,082 %"},{"name":"1 kHz to 5 kHz","range":"220 mA to 300 mA","cmc":"0,12 %"},{"name":"5 kHz to 10 kHz","range":"220 mA to 300 mA","cmc":"0,93 %"},{"name":"20 Hz to 1 kHz","range":"300 mA to 400 mA","cmc":"0,078 %"},{"name":"1 kHz to 5 kHz","range":"300 mA to 400 mA","cmc":"0,11 %"},{"name":"5 kHz to 10 kHz","range":"300 mA to 400 mA","cmc":"0,91 %"},{"name":"20 Hz to 1 kHz","range":"400 mA to 500 mA","cmc":"0,075 %"},{"name":"1 kHz to 5 kHz","range":"400 mA to 500 mA","cmc":"0,098 %"},{"name":"5 kHz to 10 kHz","range":"400 mA to 500 mA","cmc":"0,90 %"},{"name":"20 Hz to 1 kHz","range":"500 mA to 600 mA","cmc":"0,074 %"},{"name":"1 kHz to 5 kHz","range":"500 mA to 600 mA","cmc":"0,094 %"},{"name":"5 kHz to 10 kHz","range":"500 mA to 600 mA","cmc":"0,89 %"},{"name":"20 Hz to 1 kHz","range":"600 mA to 1 A","cmc":"0,072 %"},{"name":"1 kHz to 5 kHz","range":"600 mA to 1 A","cmc":"0,092 %"},{"name":"5 kHz to 10 kHz","range":"600 mA to 1 A","cmc":"0,89 %"},{"name":"20 Hz to 1 kHz","range":"1 A to 2,2 A","cmc":"0,070 %"},{"name":"1 kHz to 5 kHz","range":"1 A to 2,2 A","cmc":"0,086 %"},{"name":"5 kHz to 10 kHz","range":"1 A to 2,2 A","cmc":"0,88 %"},{"name":"10 Hz to 1 kHz","range":"2,2 A to 3 A","cmc":"0,16 %"},{"name":"1 kHz to 5 kHz","range":"2,2 A to 3 A","cmc":"0,22 %"},{"name":"5 kHz to 10 kHz","range":"2,2 A to 3 A","cmc":"0,60 %"},{"name":"10 Hz to 1 kHz","range":"3 A to 5 A","cmc":"0,14 %"},{"name":"1 kHz to 5 kHz","range":"3 A to 5 A","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"3 A to 5 A","cmc":"0,51 %"},{"name":"10 Hz to 1 kHz","range":"5 A to 11 A","cmc":"0,13 %"},{"name":"1 kHz to 5 kHz","range":"5 A to 11 A","cmc":"0,18 %"},{"name":"5 kHz to 10 kHz","range":"5 A to 11 A","cmc":"0,42 %"},{"name":"30 Hz to 45 Hz","range":"11 A to 15 A","cmc":"0,23 %"},{"name":"45 Hz to 100 Hz","range":"11 A to 15 A","cmc":"0,12 %"},{"name":"100 Hz to 1 kHz","range":"11 A to 15 A","cmc":"0,52 %"},{"name":"30 Hz to 45 Hz","range":"15 A to 25 A","cmc":"0,22 %"},{"name":"45 Hz to 100 Hz","range":"15 A to 25 A","cmc":"0,12 %"},{"name":"100 Hz to 1 kHz","range":"15 A to 25 A","cmc":"0,51 %"},{"name":"30 Hz to 45 Hz","range":"25 A to 30 A","cmc":"0,21 %"},{"name":"45 Hz to 100 Hz","range":"25 A to 30 A","cmc":"0,11 %"},{"name":"100 Hz to 1 kHz","range":"25 A to 30 A","cmc":"0,49 %"},{"name":"50 Hz","range":"2,2 A to 3 A","cmc":"0,12 %"},{"name":"50 Hz","range":"3 A to 4 A","cmc":"0,095 %"},{"name":"50 Hz","range":"4 A to 5 A","cmc":"0,084 %"},{"name":"50 Hz","range":"5 A to 6 A","cmc":"0,077 %"},{"name":"50 Hz","range":"6 A to 7 A","cmc":"0,073 %"},{"name":"50 Hz","range":"7 A to 8 A","cmc":"0,070 %"},{"name":"50 Hz","range":"8 A to 10 A","cmc":"0,067 %"},{"name":"50 Hz","range":"10 A to 11 A","cmc":"0,064 %"},{"name":"50 Hz","range":"11 A to 15 A","cmc":"0,10 %"},{"name":"50 Hz","range":"15 A to 20 A","cmc":"0,081 %"},{"name":"50 Hz","range":"20 A to 90 A","cmc":"0,090 %"}],"parameters_zh":[{"name":"10 Hz 至 20 Hz","range":"10 µA 至 20 µA","cmc":"40 nA"},{"name":"20 Hz 至 40 Hz","range":"10 µA 至 20 µA","cmc":"28 nA"},{"name":"40 Hz 至 1 kHz","range":"10 µA 至 20 µA","cmc":"18 nA"},{"name":"1 kHz 至 5 kHz","range":"10 µA 至 20 µA","cmc":"47 nA"},{"name":"5 kHz 至 10 kHz","range":"10 µA 至 20 µA","cmc":"97 nA"},{"name":"10 Hz 至 20 Hz","range":"20 µA 至 30 µA","cmc":"0,20 %"},{"name":"20 Hz 至 40 Hz","range":"20 µA 至 30 µA","cmc":"0,14 %"},{"name":"40 Hz 至 1 kHz","range":"20 µA 至 30 µA","cmc":"0,095 %"},{"name":"1 kHz 至 5 kHz","range":"20 µA 至 30 µA","cmc":"0,26 %"},{"name":"5 kHz 至 10 kHz","range":"20 µA 至 30 µA","cmc":"0,57 %"},{"name":"10 Hz 至 20 Hz","range":"30 µA 至 40 µA","cmc":"0,16 %"},{"name":"20 Hz 至 40 Hz","range":"30 µA 至 40 µA","cmc":"0,11 %"},{"name":"40 Hz 至 1 kHz","range":"30 µA 至 40 µA","cmc":"0,069 %"},{"name":"1 kHz 至 5 kHz","range":"30 µA 至 40 µA","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"30 µA 至 40 µA","cmc":"0,43 %"},{"name":"10 Hz 至 20 Hz","range":"40 µA 至 50 µA","cmc":"0,14 %"},{"name":"20 Hz 至 40 Hz","range":"40 µA 至 50 µA","cmc":"0,086 %"},{"name":"40 Hz 至 1 kHz","range":"40 µA 至 50 µA","cmc":"0,055 %"},{"name":"1 kHz 至 5 kHz","range":"40 µA 至 50 µA","cmc":"0,17 %"},{"name":"5 kHz 至 10 kHz","range":"40 µA 至 50 µA","cmc":"0,37 %"},{"name":"10 Hz 至 20 Hz","range":"50 µA 至 60 µA","cmc":"0,13 %"},{"name":"20 Hz 至 40 Hz","range":"50 µA 至 60 µA","cmc":"0,076 %"},{"name":"40 Hz 至 1 kHz","range":"50 µA 至 60 µA","cmc":"0,048 %"},{"name":"1 kHz 至 5 kHz","range":"50 µA 至 60 µA","cmc":"0,15 %"},{"name":"5 kHz 至 10 kHz","range":"50 µA 至 60 µA","cmc":"0,33 %"},{"name":"10 Hz 至 20 Hz","range":"60 µA 至 80 µA","cmc":"0,12 %"},{"name":"20 Hz 至 40 Hz","range":"60 µA 至 80 µA","cmc":"0,070 %"},{"name":"40 Hz 至 1 kHz","range":"60 µA 至 80 µA","cmc":"0,042 %"},{"name":"1 kHz 至 5 kHz","range":"60 µA 至 80 µA","cmc":"0,13 %"},{"name":"5 kHz 至 10 kHz","range":"60 µA 至 80 µA","cmc":"0,30 %"},{"name":"10 Hz 至 20 Hz","range":"80 µA 至 100 µA","cmc":"0,099 %"},{"name":"20 Hz 至 40 Hz","range":"80 µA 至 100 µA","cmc":"0,061 %"},{"name":"40 Hz 至 1 kHz","range":"80 µA 至 100 µA","cmc":"0,036 %"},{"name":"1 kHz 至 5 kHz","range":"80 µA 至 100 µA","cmc":"0,12 %"},{"name":"5 kHz 至 10 kHz","range":"80 µA 至 100 µA","cmc":"0,27 %"},{"name":"10 Hz 至 20 Hz","range":"100 µA 至 130 µA","cmc":"0,096 %"},{"name":"20 Hz 至 40 Hz","range":"100 µA 至 130 µA","cmc":"0,056 %"},{"name":"40 Hz 至 1 kHz","range":"100 µA 至 130 µA","cmc":"0,032 %"},{"name":"1 kHz 至 5 kHz","range":"100 µA 至 130 µA","cmc":"0,11 %"},{"name":"5 kHz 至 10 kHz","range":"100 µA 至 130 µA","cmc":"0,25 %"},{"name":"10 Hz 至 20 Hz","range":"130 µA 至 180 µA","cmc":"0,090 %"},{"name":"20 Hz 至 40 Hz","range":"130 µA 至 180 µA","cmc":"0,052 %"},{"name":"40 Hz 至 1 kHz","range":"130 µA 至 180 µA","cmc":"0,029 %"},{"name":"1 kHz 至 5 kHz","range":"130 µA 至 180 µA","cmc":"0,092 %"},{"name":"5 kHz 至 10 kHz","range":"130 µA 至 180 µA","cmc":"0,23 %"},{"name":"10 Hz 至 20 Hz","range":"180 µA 至 220 µA","cmc":"0,085 %"},{"name":"20 Hz 至 40 Hz","range":"180 µA 至 220 µA","cmc":"0,048 %"},{"name":"40 Hz 至 1 kHz","range":"180 µA 至 220 µA","cmc":"0,025 %"},{"name":"1 kHz 至 5 kHz","range":"180 µA 至 220 µA","cmc":"0,084 %"},{"name":"5 kHz 至 10 kHz","range":"180 µA 至 220 µA","cmc":"0,21 %"},{"name":"10 Hz 至 20 Hz","range":"220 µA 至 300 µA","cmc":"0,089 %"},{"name":"20 Hz 至 40 Hz","range":"220 µA 至 300 µA","cmc":"0,052 %"},{"name":"40 Hz 至 1 kHz","range":"220 µA 至 300 µA","cmc":"0,032 %"},{"name":"1 kHz 至 5 kHz","range":"220 µA 至 300 µA","cmc":"0,25 %"},{"name":"5 kHz 至 10 kHz","range":"220 µA 至 300 µA","cmc":"0,53 %"},{"name":"10 Hz 至 20 Hz","range":"300 µA 至 400 µA","cmc":"0,084 %"},{"name":"20 Hz 至 40 Hz","range":"300 µA 至 400 µA","cmc":"0,048 %"},{"name":"40 Hz 至 1 kHz","range":"300 µA 至 400 µA","cmc":"0,028 %"},{"name":"1 kHz 至 5 kHz","range":"300 µA 至 400 µA","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"300 µA 至 400 µA","cmc":"0,43 %"},{"name":"10 Hz 至 20 Hz","range":"400 µA 至 500 µA","cmc":"0,081 %"},{"name":"20 Hz 至 40 Hz","range":"400 µA 至 500 µA","cmc":"0,045 %"},{"name":"40 Hz 至 1 kHz","range":"400 µA 至 500 µA","cmc":"0,025 %"},{"name":"1 kHz 至 5 kHz","range":"400 µA 至 500 µA","cmc":"0,17 %"},{"name":"5 kHz 至 10 kHz","range":"400 µA 至 500 µA","cmc":"0,37 %"},{"name":"10 Hz 至 20 Hz","range":"500 µA 至 600 µA","cmc":"0,079 %"},{"name":"20 Hz 至 40 Hz","range":"500 µA 至 600 µA","cmc":"0,044 %"},{"name":"40 Hz 至 1 kHz","range":"500 µA 至 600 µA","cmc":"0,023 %"},{"name":"1 kHz 至 5 kHz","range":"500 µA 至 600 µA","cmc":"0,15 %"},{"name":"5 kHz 至 10 kHz","range":"500 µA 至 600 µA","cmc":"0,33 %"},{"name":"10 Hz 至 20 Hz","range":"600 µA 至 800 µA","cmc":"0,078 %"},{"name":"20 Hz 至 40 Hz","range":"600 µA 至 800 µA","cmc":"0,043 %"},{"name":"40 Hz 至 1 kHz","range":"600 µA 至 800 µA","cmc":"0,022 %"},{"name":"1 kHz 至 5 kHz","range":"600 µA 至 800 µA","cmc":"0,13 %"},{"name":"5 kHz 至 10 kHz","range":"600 µA 至 800 µA","cmc":"0,30 %"},{"name":"10 Hz 至 20 Hz","range":"800 µA 至 1 mA","cmc":"0,076 %"},{"name":"20 Hz 至 40 Hz","range":"800 µA 至 1 mA","cmc":"0,041 %"},{"name":"40 Hz 至 1 kHz","range":"800 µA 至 1 mA","cmc":"0,021 %"},{"name":"1 kHz 至 5 kHz","range":"800 µA 至 1 mA","cmc":"0,12 %"},{"name":"5 kHz 至 10 kHz","range":"800 µA 至 1 mA","cmc":"0,27 %"},{"name":"10 Hz 至 20 Hz","range":"1 mA 至 1,3 mA","cmc":"0,075 %"},{"name":"20 Hz 至 40 Hz","range":"1 mA 至 1,3 mA","cmc":"0,040 %"},{"name":"40 Hz 至 1 kHz","range":"1 mA 至 1,3 mA","cmc":"0,020 %"},{"name":"1 kHz 至 5 kHz","range":"1 mA 至 1,3 mA","cmc":"0,11 %"},{"name":"5 kHz 至 10 kHz","range":"1 mA 至 1,3 mA","cmc":"0,25 %"},{"name":"10 Hz 至 20 Hz","range":"1,3 mA 至 1,8 mA","cmc":"0,074 %"},{"name":"20 Hz 至 40 Hz","range":"1,3 mA 至 1,8 mA","cmc":"0,039 %"},{"name":"40 Hz 至 1 kHz","range":"1,3 mA 至 1,8 mA","cmc":"0,019 %"},{"name":"1 kHz 至 5 kHz","range":"1,3 mA 至 1,8 mA","cmc":"0,092 %"},{"name":"5 kHz 至 10 kHz","range":"1,3 mA 至 1,8 mA","cmc":"0,23 %"},{"name":"10 Hz 至 20 Hz","range":"1,8 mA 至 2,2 mA","cmc":"0,073 %"},{"name":"20 Hz 至 40 Hz","range":"1,8 mA 至 2,2 mA","cmc":"0,074 %"},{"name":"40 Hz 至 1 kHz","range":"1,8 mA 至 2,2 mA","cmc":"0,019 %"},{"name":"1 kHz 至 5 kHz","range":"1,8 mA 至 2,2 mA","cmc":"0,084 %"},{"name":"5 kHz 至 10 kHz","range":"1,8 mA 至 2,2 mA","cmc":"0,21 %"},{"name":"10 Hz 至 20 Hz","range":"2,2 mA 至 3 mA","cmc":"0,089 %"},{"name":"20 Hz 至 40 Hz","range":"2,2 mA 至 3 mA","cmc":"0,052 %"},{"name":"40 Hz 至 1 kHz","range":"2,2 mA 至 3 mA","cmc":"0,032 %"},{"name":"1 kHz 至 5 kHz","range":"2,2 mA 至 3 mA","cmc":"0,25 %"},{"name":"5 kHz 至 10 kHz","range":"2,2 mA 至 3 mA","cmc":"0,53 %"},{"name":"10 Hz 至 20 Hz","range":"3 mA 至 4 mA","cmc":"0,084 %"},{"name":"20 Hz 至 40 Hz","range":"3 mA 至 4 mA","cmc":"0,048 %"},{"name":"40 Hz 至 1 kHz","range":"3 mA 至 4 mA","cmc":"0,028 %"},{"name":"1 kHz 至 5 kHz","range":"3 mA 至 4 mA","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"3 mA 至 4 mA","cmc":"0,43 %"},{"name":"10 Hz 至 20 Hz","range":"4 mA 至 5 mA","cmc":"0,081 %"},{"name":"20 Hz 至 40 Hz","range":"4 mA 至 5 mA","cmc":"0,045 %"},{"name":"40 Hz 至 1 kHz","range":"4 mA 至 5 mA","cmc":"0,025 %"},{"name":"1 kHz 至 5 kHz","range":"4 mA 至 5 mA","cmc":"0,17 %"},{"name":"5 kHz 至 10 kHz","range":"4 mA 至 5 mA","cmc":"0,37 %"},{"name":"10 Hz 至 20 Hz","range":"5 mA 至 6 mA","cmc":"0,079 %"},{"name":"20 Hz 至 40 Hz","range":"5 mA 至 6 mA","cmc":"0,043 %"},{"name":"40 Hz 至 1 kHz","range":"5 mA 至 6 mA","cmc":"0,023 %"},{"name":"1 kHz 至 5 kHz","range":"5 mA 至 6 mA","cmc":"0,15 %"},{"name":"5 kHz 至 10 kHz","range":"5 mA 至 6 mA","cmc":"0,33 %"},{"name":"10 Hz 至 20 Hz","range":"6 mA 至 8 mA","cmc":"0,078 %"},{"name":"20 Hz 至 40 Hz","range":"6 mA 至 8 mA","cmc":"0,042 %"},{"name":"40 Hz 至 1 kHz","range":"6 mA 至 8 mA","cmc":"0,022 %"},{"name":"1 kHz 至 5 kHz","range":"6 mA 至 8 mA","cmc":"0,13 %"},{"name":"5 kHz 至 10 kHz","range":"6 mA 至 8 mA","cmc":"0,30 %"},{"name":"10 Hz 至 20 Hz","range":"8 mA 至 10 mA","cmc":"0,076 %"},{"name":"20 Hz 至 40 Hz","range":"8 mA 至 10 mA","cmc":"0,041 %"},{"name":"40 Hz 至 1 kHz","range":"8 mA 至 10 mA","cmc":"0,021 %"},{"name":"1 kHz 至 5 kHz","range":"8 mA 至 10 mA","cmc":"0,12 %"},{"name":"5 kHz 至 10 kHz","range":"8 mA 至 10 mA","cmc":"0,27 %"},{"name":"10 Hz 至 20 Hz","range":"10 mA 至 13 mA","cmc":"0,075 %"},{"name":"20 Hz 至 40 Hz","range":"10 mA 至 13 mA","cmc":"0,040 %"},{"name":"40 Hz 至 1 kHz","range":"10 mA 至 13 mA","cmc":"0,020 %"},{"name":"1 kHz 至 5 kHz","range":"10 mA 至 13 mA","cmc":"0,11 %"},{"name":"5 kHz 至 10 kHz","range":"10 mA 至 13 mA","cmc":"0,25 %"},{"name":"10 Hz 至 20 Hz","range":"13 mA 至 18 mA","cmc":"0,074 %"},{"name":"20 Hz 至 40 Hz","range":"13 mA 至 18 mA","cmc":"0,039 %"},{"name":"40 Hz 至 1 kHz","range":"13 mA 至 18 mA","cmc":"0,019 %"},{"name":"1 kHz 至 5 kHz","range":"13 mA 至 18 mA","cmc":"0,092 %"},{"name":"5 kHz 至 10 kHz","range":"13 mA 至 18 mA","cmc":"0,23 %"},{"name":"10 Hz 至 20 Hz","range":"18 mA 至 22 mA","cmc":"0,073 %"},{"name":"20 Hz 至 40 Hz","range":"18 mA 至 22 mA","cmc":"0,039 %"},{"name":"40 Hz 至 1 kHz","range":"18 mA 至 22 mA","cmc":"0,019 %"},{"name":"1 kHz 至 5 kHz","range":"18 mA 至 22 mA","cmc":"0,084 %"},{"name":"5 kHz 至 10 kHz","range":"18 mA 至 22 mA","cmc":"0,21 %"},{"name":"10 Hz 至 20 Hz","range":"22 mA 至 30 mA","cmc":"0,089 %"},{"name":"20 Hz 至 40 Hz","range":"22 mA 至 30 mA","cmc":"0,052 %"},{"name":"40 Hz 至 1 kHz","range":"22 mA 至 30 mA","cmc":"0,032 %"},{"name":"1 kHz 至 5 kHz","range":"22 mA 至 30 mA","cmc":"0,25 %"},{"name":"5 kHz 至 10 kHz","range":"22 mA 至 30 mA","cmc":"0,53 %"},{"name":"10 Hz 至 20 Hz","range":"30 mA 至 40 mA","cmc":"0,084 %"},{"name":"20 Hz 至 40 Hz","range":"30 mA 至 40 mA","cmc":"0,048 %"},{"name":"40 Hz 至 1 kHz","range":"30 mA 至 40 mA","cmc":"0,028 %"},{"name":"1 kHz 至 5 kHz","range":"30 mA 至 40 mA","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"30 mA 至 40 mA","cmc":"0,43 %"},{"name":"10 Hz 至 20 Hz","range":"40 mA 至 50 mA","cmc":"0,081 %"},{"name":"20 Hz 至 40 Hz","range":"40 mA 至 50 mA","cmc":"0,045 %"},{"name":"40 Hz 至 1 kHz","range":"40 mA 至 50 mA","cmc":"0,025 %"},{"name":"1 kHz 至 5 kHz","range":"40 mA 至 50 mA","cmc":"0,17 %"},{"name":"5 kHz 至 10 kHz","range":"40 mA 至 50 mA","cmc":"0,37 %"},{"name":"10 Hz 至 20 Hz","range":"50 mA 至 60 mA","cmc":"0,079 %"},{"name":"20 Hz 至 40 Hz","range":"50 mA 至 60 mA","cmc":"0,043 %"},{"name":"40 Hz 至 1 kHz","range":"50 mA 至 60 mA","cmc":"0,023 %"},{"name":"1 kHz 至 5 kHz","range":"50 mA 至 60 mA","cmc":"0,15 %"},{"name":"5 kHz 至 10 kHz","range":"50 mA 至 60 mA","cmc":"0,33 %"},{"name":"10 Hz 至 20 Hz","range":"60 mA 至 80 mA","cmc":"0,078 %"},{"name":"20 Hz 至 40 Hz","range":"60 mA 至 80 mA","cmc":"0,042 %"},{"name":"40 Hz 至 1 kHz","range":"60 mA 至 80 mA","cmc":"0,022 %"},{"name":"1 kHz 至 5 kHz","range":"60 mA 至 80 mA","cmc":"0,13 %"},{"name":"5 kHz 至 10 kHz","range":"60 mA 至 80 mA","cmc":"0,30 %"},{"name":"10 Hz 至 20 Hz","range":"80 mA 至 100 mA","cmc":"0,076 %"},{"name":"20 Hz 至 40 Hz","range":"80 mA 至 100 mA","cmc":"0,041 %"},{"name":"40 Hz 至 1 kHz","range":"80 mA 至 100 mA","cmc":"0,021 %"},{"name":"1 kHz 至 5 kHz","range":"80 mA 至 100 mA","cmc":"0,12 %"},{"name":"5 kHz 至 10 kHz","range":"80 mA 至 100 mA","cmc":"0,27 %"},{"name":"10 Hz 至 20 Hz","range":"100 mA 至 130 mA","cmc":"0,075 %"},{"name":"20 Hz 至 40 Hz","range":"100 mA 至 130 mA","cmc":"0,040 %"},{"name":"40 Hz 至 1 kHz","range":"100 mA 至 130 mA","cmc":"0,020 %"},{"name":"1 kHz 至 5 kHz","range":"100 mA 至 130 mA","cmc":"0,11 %"},{"name":"5 kHz 至 10 kHz","range":"100 mA 至 130 mA","cmc":"0,25 %"},{"name":"10 Hz 至 20 Hz","range":"130 mA 至 180 mA","cmc":"0,074 %"},{"name":"20 Hz 至 40 Hz","range":"130 mA 至 180 mA","cmc":"0,039 %"},{"name":"40 Hz 至 1 kHz","range":"130 mA 至 180 mA","cmc":"0,019 %"},{"name":"1 kHz 至 5 kHz","range":"130 mA 至 180 mA","cmc":"0,092 %"},{"name":"5 kHz 至 10 kHz","range":"130 mA 至 180 mA","cmc":"0,24 %"},{"name":"10 Hz 至 20 Hz","range":"180 mA 至 220 mA","cmc":"0,073 %"},{"name":"20 Hz 至 40 Hz","range":"180 mA 至 220 mA","cmc":"0,038 %"},{"name":"40 Hz 至 1 kHz","range":"180 mA 至 220 mA","cmc":"0,019 %"},{"name":"1 kHz 至 5 kHz","range":"180 mA 至 220 mA","cmc":"0,084 %"},{"name":"5 kHz 至 10 kHz","range":"180 mA 至 220 mA","cmc":"0,21 %"},{"name":"20 Hz 至 1 kHz","range":"220 mA 至 300 mA","cmc":"0,082 %"},{"name":"1 kHz 至 5 kHz","range":"220 mA 至 300 mA","cmc":"0,12 %"},{"name":"5 kHz 至 10 kHz","range":"220 mA 至 300 mA","cmc":"0,93 %"},{"name":"20 Hz 至 1 kHz","range":"300 mA 至 400 mA","cmc":"0,078 %"},{"name":"1 kHz 至 5 kHz","range":"300 mA 至 400 mA","cmc":"0,11 %"},{"name":"5 kHz 至 10 kHz","range":"300 mA 至 400 mA","cmc":"0,91 %"},{"name":"20 Hz 至 1 kHz","range":"400 mA 至 500 mA","cmc":"0,075 %"},{"name":"1 kHz 至 5 kHz","range":"400 mA 至 500 mA","cmc":"0,098 %"},{"name":"5 kHz 至 10 kHz","range":"400 mA 至 500 mA","cmc":"0,90 %"},{"name":"20 Hz 至 1 kHz","range":"500 mA 至 600 mA","cmc":"0,074 %"},{"name":"1 kHz 至 5 kHz","range":"500 mA 至 600 mA","cmc":"0,094 %"},{"name":"5 kHz 至 10 kHz","range":"500 mA 至 600 mA","cmc":"0,89 %"},{"name":"20 Hz 至 1 kHz","range":"600 mA 至 1 A","cmc":"0,072 %"},{"name":"1 kHz 至 5 kHz","range":"600 mA 至 1 A","cmc":"0,092 %"},{"name":"5 kHz 至 10 kHz","range":"600 mA 至 1 A","cmc":"0,89 %"},{"name":"20 Hz 至 1 kHz","range":"1 A 至 2,2 A","cmc":"0,070 %"},{"name":"1 kHz 至 5 kHz","range":"1 A 至 2,2 A","cmc":"0,086 %"},{"name":"5 kHz 至 10 kHz","range":"1 A 至 2,2 A","cmc":"0,88 %"},{"name":"10 Hz 至 1 kHz","range":"2,2 A 至 3 A","cmc":"0,16 %"},{"name":"1 kHz 至 5 kHz","range":"2,2 A 至 3 A","cmc":"0,22 %"},{"name":"5 kHz 至 10 kHz","range":"2,2 A 至 3 A","cmc":"0,60 %"},{"name":"10 Hz 至 1 kHz","range":"3 A 至 5 A","cmc":"0,14 %"},{"name":"1 kHz 至 5 kHz","range":"3 A 至 5 A","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"3 A 至 5 A","cmc":"0,51 %"},{"name":"10 Hz 至 1 kHz","range":"5 A 至 11 A","cmc":"0,13 %"},{"name":"1 kHz 至 5 kHz","range":"5 A 至 11 A","cmc":"0,18 %"},{"name":"5 kHz 至 10 kHz","range":"5 A 至 11 A","cmc":"0,42 %"},{"name":"30 Hz 至 45 Hz","range":"11 A 至 15 A","cmc":"0,23 %"},{"name":"45 Hz 至 100 Hz","range":"11 A 至 15 A","cmc":"0,12 %"},{"name":"100 Hz 至 1 kHz","range":"11 A 至 15 A","cmc":"0,52 %"},{"name":"30 Hz 至 45 Hz","range":"15 A 至 25 A","cmc":"0,22 %"},{"name":"45 Hz 至 100 Hz","range":"15 A 至 25 A","cmc":"0,12 %"},{"name":"100 Hz 至 1 kHz","range":"15 A 至 25 A","cmc":"0,51 %"},{"name":"30 Hz 至 45 Hz","range":"25 A 至 30 A","cmc":"0,21 %"},{"name":"45 Hz 至 100 Hz","range":"25 A 至 30 A","cmc":"0,11 %"},{"name":"100 Hz 至 1 kHz","range":"25 A 至 30 A","cmc":"0,49 %"},{"name":"50 Hz","range":"2,2 A 至 3 A","cmc":"0,12 %"},{"name":"50 Hz","range":"3 A 至 4 A","cmc":"0,095 %"},{"name":"50 Hz","range":"4 A 至 5 A","cmc":"0,084 %"},{"name":"50 Hz","range":"5 A 至 6 A","cmc":"0,077 %"},{"name":"50 Hz","range":"6 A 至 7 A","cmc":"0,073 %"},{"name":"50 Hz","range":"7 A 至 8 A","cmc":"0,070 %"},{"name":"50 Hz","range":"8 A 至 10 A","cmc":"0,067 %"},{"name":"50 Hz","range":"10 A 至 11 A","cmc":"0,064 %"},{"name":"50 Hz","range":"11 A 至 15 A","cmc":"0,10 %"},{"name":"50 Hz","range":"15 A 至 20 A","cmc":"0,081 %"},{"name":"50 Hz","range":"20 A 至 90 A","cmc":"0,090 %"}],"parameters_cs":[{"name":"10 Hz až 20 Hz","range":"10 µA až 20 µA","cmc":"40 nA"},{"name":"20 Hz až 40 Hz","range":"10 µA až 20 µA","cmc":"28 nA"},{"name":"40 Hz až 1 kHz","range":"10 µA až 20 µA","cmc":"18 nA"},{"name":"1 kHz až 5 kHz","range":"10 µA až 20 µA","cmc":"47 nA"},{"name":"5 kHz až 10 kHz","range":"10 µA až 20 µA","cmc":"97 nA"},{"name":"10 Hz až 20 Hz","range":"20 µA až 30 µA","cmc":"0,20 %"},{"name":"20 Hz až 40 Hz","range":"20 µA až 30 µA","cmc":"0,14 %"},{"name":"40 Hz až 1 kHz","range":"20 µA až 30 µA","cmc":"0,095 %"},{"name":"1 kHz až 5 kHz","range":"20 µA až 30 µA","cmc":"0,26 %"},{"name":"5 kHz až 10 kHz","range":"20 µA až 30 µA","cmc":"0,57 %"},{"name":"10 Hz až 20 Hz","range":"30 µA až 40 µA","cmc":"0,16 %"},{"name":"20 Hz až 40 Hz","range":"30 µA až 40 µA","cmc":"0,11 %"},{"name":"40 Hz až 1 kHz","range":"30 µA až 40 µA","cmc":"0,069 %"},{"name":"1 kHz až 5 kHz","range":"30 µA až 40 µA","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"30 µA až 40 µA","cmc":"0,43 %"},{"name":"10 Hz až 20 Hz","range":"40 µA až 50 µA","cmc":"0,14 %"},{"name":"20 Hz až 40 Hz","range":"40 µA až 50 µA","cmc":"0,086 %"},{"name":"40 Hz až 1 kHz","range":"40 µA až 50 µA","cmc":"0,055 %"},{"name":"1 kHz až 5 kHz","range":"40 µA až 50 µA","cmc":"0,17 %"},{"name":"5 kHz až 10 kHz","range":"40 µA až 50 µA","cmc":"0,37 %"},{"name":"10 Hz až 20 Hz","range":"50 µA až 60 µA","cmc":"0,13 %"},{"name":"20 Hz až 40 Hz","range":"50 µA až 60 µA","cmc":"0,076 %"},{"name":"40 Hz až 1 kHz","range":"50 µA až 60 µA","cmc":"0,048 %"},{"name":"1 kHz až 5 kHz","range":"50 µA až 60 µA","cmc":"0,15 %"},{"name":"5 kHz až 10 kHz","range":"50 µA až 60 µA","cmc":"0,33 %"},{"name":"10 Hz až 20 Hz","range":"60 µA až 80 µA","cmc":"0,12 %"},{"name":"20 Hz až 40 Hz","range":"60 µA až 80 µA","cmc":"0,070 %"},{"name":"40 Hz až 1 kHz","range":"60 µA až 80 µA","cmc":"0,042 %"},{"name":"1 kHz až 5 kHz","range":"60 µA až 80 µA","cmc":"0,13 %"},{"name":"5 kHz až 10 kHz","range":"60 µA až 80 µA","cmc":"0,30 %"},{"name":"10 Hz až 20 Hz","range":"80 µA až 100 µA","cmc":"0,099 %"},{"name":"20 Hz až 40 Hz","range":"80 µA až 100 µA","cmc":"0,061 %"},{"name":"40 Hz až 1 kHz","range":"80 µA až 100 µA","cmc":"0,036 %"},{"name":"1 kHz až 5 kHz","range":"80 µA až 100 µA","cmc":"0,12 %"},{"name":"5 kHz až 10 kHz","range":"80 µA až 100 µA","cmc":"0,27 %"},{"name":"10 Hz až 20 Hz","range":"100 µA až 130 µA","cmc":"0,096 %"},{"name":"20 Hz až 40 Hz","range":"100 µA až 130 µA","cmc":"0,056 %"},{"name":"40 Hz až 1 kHz","range":"100 µA až 130 µA","cmc":"0,032 %"},{"name":"1 kHz až 5 kHz","range":"100 µA až 130 µA","cmc":"0,11 %"},{"name":"5 kHz až 10 kHz","range":"100 µA až 130 µA","cmc":"0,25 %"},{"name":"10 Hz až 20 Hz","range":"130 µA až 180 µA","cmc":"0,090 %"},{"name":"20 Hz až 40 Hz","range":"130 µA až 180 µA","cmc":"0,052 %"},{"name":"40 Hz až 1 kHz","range":"130 µA až 180 µA","cmc":"0,029 %"},{"name":"1 kHz až 5 kHz","range":"130 µA až 180 µA","cmc":"0,092 %"},{"name":"5 kHz až 10 kHz","range":"130 µA až 180 µA","cmc":"0,23 %"},{"name":"10 Hz až 20 Hz","range":"180 µA až 220 µA","cmc":"0,085 %"},{"name":"20 Hz až 40 Hz","range":"180 µA až 220 µA","cmc":"0,048 %"},{"name":"40 Hz až 1 kHz","range":"180 µA až 220 µA","cmc":"0,025 %"},{"name":"1 kHz až 5 kHz","range":"180 µA až 220 µA","cmc":"0,084 %"},{"name":"5 kHz až 10 kHz","range":"180 µA až 220 µA","cmc":"0,21 %"},{"name":"10 Hz až 20 Hz","range":"220 µA až 300 µA","cmc":"0,089 %"},{"name":"20 Hz až 40 Hz","range":"220 µA až 300 µA","cmc":"0,052 %"},{"name":"40 Hz až 1 kHz","range":"220 µA až 300 µA","cmc":"0,032 %"},{"name":"1 kHz až 5 kHz","range":"220 µA až 300 µA","cmc":"0,25 %"},{"name":"5 kHz až 10 kHz","range":"220 µA až 300 µA","cmc":"0,53 %"},{"name":"10 Hz až 20 Hz","range":"300 µA až 400 µA","cmc":"0,084 %"},{"name":"20 Hz až 40 Hz","range":"300 µA až 400 µA","cmc":"0,048 %"},{"name":"40 Hz až 1 kHz","range":"300 µA až 400 µA","cmc":"0,028 %"},{"name":"1 kHz až 5 kHz","range":"300 µA až 400 µA","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"300 µA až 400 µA","cmc":"0,43 %"},{"name":"10 Hz až 20 Hz","range":"400 µA až 500 µA","cmc":"0,081 %"},{"name":"20 Hz až 40 Hz","range":"400 µA až 500 µA","cmc":"0,045 %"},{"name":"40 Hz až 1 kHz","range":"400 µA až 500 µA","cmc":"0,025 %"},{"name":"1 kHz až 5 kHz","range":"400 µA až 500 µA","cmc":"0,17 %"},{"name":"5 kHz až 10 kHz","range":"400 µA až 500 µA","cmc":"0,37 %"},{"name":"10 Hz až 20 Hz","range":"500 µA až 600 µA","cmc":"0,079 %"},{"name":"20 Hz až 40 Hz","range":"500 µA až 600 µA","cmc":"0,044 %"},{"name":"40 Hz až 1 kHz","range":"500 µA až 600 µA","cmc":"0,023 %"},{"name":"1 kHz až 5 kHz","range":"500 µA až 600 µA","cmc":"0,15 %"},{"name":"5 kHz až 10 kHz","range":"500 µA až 600 µA","cmc":"0,33 %"},{"name":"10 Hz až 20 Hz","range":"600 µA až 800 µA","cmc":"0,078 %"},{"name":"20 Hz až 40 Hz","range":"600 µA až 800 µA","cmc":"0,043 %"},{"name":"40 Hz až 1 kHz","range":"600 µA až 800 µA","cmc":"0,022 %"},{"name":"1 kHz až 5 kHz","range":"600 µA až 800 µA","cmc":"0,13 %"},{"name":"5 kHz až 10 kHz","range":"600 µA až 800 µA","cmc":"0,30 %"},{"name":"10 Hz až 20 Hz","range":"800 µA až 1 mA","cmc":"0,076 %"},{"name":"20 Hz až 40 Hz","range":"800 µA až 1 mA","cmc":"0,041 %"},{"name":"40 Hz až 1 kHz","range":"800 µA až 1 mA","cmc":"0,021 %"},{"name":"1 kHz až 5 kHz","range":"800 µA až 1 mA","cmc":"0,12 %"},{"name":"5 kHz až 10 kHz","range":"800 µA až 1 mA","cmc":"0,27 %"},{"name":"10 Hz až 20 Hz","range":"1 mA až 1,3 mA","cmc":"0,075 %"},{"name":"20 Hz až 40 Hz","range":"1 mA až 1,3 mA","cmc":"0,040 %"},{"name":"40 Hz až 1 kHz","range":"1 mA až 1,3 mA","cmc":"0,020 %"},{"name":"1 kHz až 5 kHz","range":"1 mA až 1,3 mA","cmc":"0,11 %"},{"name":"5 kHz až 10 kHz","range":"1 mA až 1,3 mA","cmc":"0,25 %"},{"name":"10 Hz až 20 Hz","range":"1,3 mA až 1,8 mA","cmc":"0,074 %"},{"name":"20 Hz až 40 Hz","range":"1,3 mA až 1,8 mA","cmc":"0,039 %"},{"name":"40 Hz až 1 kHz","range":"1,3 mA až 1,8 mA","cmc":"0,019 %"},{"name":"1 kHz až 5 kHz","range":"1,3 mA až 1,8 mA","cmc":"0,092 %"},{"name":"5 kHz až 10 kHz","range":"1,3 mA až 1,8 mA","cmc":"0,23 %"},{"name":"10 Hz až 20 Hz","range":"1,8 mA až 2,2 mA","cmc":"0,073 %"},{"name":"20 Hz až 40 Hz","range":"1,8 mA až 2,2 mA","cmc":"0,074 %"},{"name":"40 Hz až 1 kHz","range":"1,8 mA až 2,2 mA","cmc":"0,019 %"},{"name":"1 kHz až 5 kHz","range":"1,8 mA až 2,2 mA","cmc":"0,084 %"},{"name":"5 kHz až 10 kHz","range":"1,8 mA až 2,2 mA","cmc":"0,21 %"},{"name":"10 Hz až 20 Hz","range":"2,2 mA až 3 mA","cmc":"0,089 %"},{"name":"20 Hz až 40 Hz","range":"2,2 mA až 3 mA","cmc":"0,052 %"},{"name":"40 Hz až 1 kHz","range":"2,2 mA až 3 mA","cmc":"0,032 %"},{"name":"1 kHz až 5 kHz","range":"2,2 mA až 3 mA","cmc":"0,25 %"},{"name":"5 kHz až 10 kHz","range":"2,2 mA až 3 mA","cmc":"0,53 %"},{"name":"10 Hz až 20 Hz","range":"3 mA až 4 mA","cmc":"0,084 %"},{"name":"20 Hz až 40 Hz","range":"3 mA až 4 mA","cmc":"0,048 %"},{"name":"40 Hz až 1 kHz","range":"3 mA až 4 mA","cmc":"0,028 %"},{"name":"1 kHz až 5 kHz","range":"3 mA až 4 mA","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"3 mA až 4 mA","cmc":"0,43 %"},{"name":"10 Hz až 20 Hz","range":"4 mA až 5 mA","cmc":"0,081 %"},{"name":"20 Hz až 40 Hz","range":"4 mA až 5 mA","cmc":"0,045 %"},{"name":"40 Hz až 1 kHz","range":"4 mA až 5 mA","cmc":"0,025 %"},{"name":"1 kHz až 5 kHz","range":"4 mA až 5 mA","cmc":"0,17 %"},{"name":"5 kHz až 10 kHz","range":"4 mA až 5 mA","cmc":"0,37 %"},{"name":"10 Hz až 20 Hz","range":"5 mA až 6 mA","cmc":"0,079 %"},{"name":"20 Hz až 40 Hz","range":"5 mA až 6 mA","cmc":"0,043 %"},{"name":"40 Hz až 1 kHz","range":"5 mA až 6 mA","cmc":"0,023 %"},{"name":"1 kHz až 5 kHz","range":"5 mA až 6 mA","cmc":"0,15 %"},{"name":"5 kHz až 10 kHz","range":"5 mA až 6 mA","cmc":"0,33 %"},{"name":"10 Hz až 20 Hz","range":"6 mA až 8 mA","cmc":"0,078 %"},{"name":"20 Hz až 40 Hz","range":"6 mA až 8 mA","cmc":"0,042 %"},{"name":"40 Hz až 1 kHz","range":"6 mA až 8 mA","cmc":"0,022 %"},{"name":"1 kHz až 5 kHz","range":"6 mA až 8 mA","cmc":"0,13 %"},{"name":"5 kHz až 10 kHz","range":"6 mA až 8 mA","cmc":"0,30 %"},{"name":"10 Hz až 20 Hz","range":"8 mA až 10 mA","cmc":"0,076 %"},{"name":"20 Hz až 40 Hz","range":"8 mA až 10 mA","cmc":"0,041 %"},{"name":"40 Hz až 1 kHz","range":"8 mA až 10 mA","cmc":"0,021 %"},{"name":"1 kHz až 5 kHz","range":"8 mA až 10 mA","cmc":"0,12 %"},{"name":"5 kHz až 10 kHz","range":"8 mA až 10 mA","cmc":"0,27 %"},{"name":"10 Hz až 20 Hz","range":"10 mA až 13 mA","cmc":"0,075 %"},{"name":"20 Hz až 40 Hz","range":"10 mA až 13 mA","cmc":"0,040 %"},{"name":"40 Hz až 1 kHz","range":"10 mA až 13 mA","cmc":"0,020 %"},{"name":"1 kHz až 5 kHz","range":"10 mA až 13 mA","cmc":"0,11 %"},{"name":"5 kHz až 10 kHz","range":"10 mA až 13 mA","cmc":"0,25 %"},{"name":"10 Hz až 20 Hz","range":"13 mA až 18 mA","cmc":"0,074 %"},{"name":"20 Hz až 40 Hz","range":"13 mA až 18 mA","cmc":"0,039 %"},{"name":"40 Hz až 1 kHz","range":"13 mA až 18 mA","cmc":"0,019 %"},{"name":"1 kHz až 5 kHz","range":"13 mA až 18 mA","cmc":"0,092 %"},{"name":"5 kHz až 10 kHz","range":"13 mA až 18 mA","cmc":"0,23 %"},{"name":"10 Hz až 20 Hz","range":"18 mA až 22 mA","cmc":"0,073 %"},{"name":"20 Hz až 40 Hz","range":"18 mA až 22 mA","cmc":"0,039 %"},{"name":"40 Hz až 1 kHz","range":"18 mA až 22 mA","cmc":"0,019 %"},{"name":"1 kHz až 5 kHz","range":"18 mA až 22 mA","cmc":"0,084 %"},{"name":"5 kHz až 10 kHz","range":"18 mA až 22 mA","cmc":"0,21 %"},{"name":"10 Hz až 20 Hz","range":"22 mA až 30 mA","cmc":"0,089 %"},{"name":"20 Hz až 40 Hz","range":"22 mA až 30 mA","cmc":"0,052 %"},{"name":"40 Hz až 1 kHz","range":"22 mA až 30 mA","cmc":"0,032 %"},{"name":"1 kHz až 5 kHz","range":"22 mA až 30 mA","cmc":"0,25 %"},{"name":"5 kHz až 10 kHz","range":"22 mA až 30 mA","cmc":"0,53 %"},{"name":"10 Hz až 20 Hz","range":"30 mA až 40 mA","cmc":"0,084 %"},{"name":"20 Hz až 40 Hz","range":"30 mA až 40 mA","cmc":"0,048 %"},{"name":"40 Hz až 1 kHz","range":"30 mA až 40 mA","cmc":"0,028 %"},{"name":"1 kHz až 5 kHz","range":"30 mA až 40 mA","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"30 mA až 40 mA","cmc":"0,43 %"},{"name":"10 Hz až 20 Hz","range":"40 mA až 50 mA","cmc":"0,081 %"},{"name":"20 Hz až 40 Hz","range":"40 mA až 50 mA","cmc":"0,045 %"},{"name":"40 Hz až 1 kHz","range":"40 mA až 50 mA","cmc":"0,025 %"},{"name":"1 kHz až 5 kHz","range":"40 mA až 50 mA","cmc":"0,17 %"},{"name":"5 kHz až 10 kHz","range":"40 mA až 50 mA","cmc":"0,37 %"},{"name":"10 Hz až 20 Hz","range":"50 mA až 60 mA","cmc":"0,079 %"},{"name":"20 Hz až 40 Hz","range":"50 mA až 60 mA","cmc":"0,043 %"},{"name":"40 Hz až 1 kHz","range":"50 mA až 60 mA","cmc":"0,023 %"},{"name":"1 kHz až 5 kHz","range":"50 mA až 60 mA","cmc":"0,15 %"},{"name":"5 kHz až 10 kHz","range":"50 mA až 60 mA","cmc":"0,33 %"},{"name":"10 Hz až 20 Hz","range":"60 mA až 80 mA","cmc":"0,078 %"},{"name":"20 Hz až 40 Hz","range":"60 mA až 80 mA","cmc":"0,042 %"},{"name":"40 Hz až 1 kHz","range":"60 mA až 80 mA","cmc":"0,022 %"},{"name":"1 kHz až 5 kHz","range":"60 mA až 80 mA","cmc":"0,13 %"},{"name":"5 kHz až 10 kHz","range":"60 mA až 80 mA","cmc":"0,30 %"},{"name":"10 Hz až 20 Hz","range":"80 mA až 100 mA","cmc":"0,076 %"},{"name":"20 Hz až 40 Hz","range":"80 mA až 100 mA","cmc":"0,041 %"},{"name":"40 Hz až 1 kHz","range":"80 mA až 100 mA","cmc":"0,021 %"},{"name":"1 kHz až 5 kHz","range":"80 mA až 100 mA","cmc":"0,12 %"},{"name":"5 kHz až 10 kHz","range":"80 mA až 100 mA","cmc":"0,27 %"},{"name":"10 Hz až 20 Hz","range":"100 mA až 130 mA","cmc":"0,075 %"},{"name":"20 Hz až 40 Hz","range":"100 mA až 130 mA","cmc":"0,040 %"},{"name":"40 Hz až 1 kHz","range":"100 mA až 130 mA","cmc":"0,020 %"},{"name":"1 kHz až 5 kHz","range":"100 mA až 130 mA","cmc":"0,11 %"},{"name":"5 kHz až 10 kHz","range":"100 mA až 130 mA","cmc":"0,25 %"},{"name":"10 Hz až 20 Hz","range":"130 mA až 180 mA","cmc":"0,074 %"},{"name":"20 Hz až 40 Hz","range":"130 mA až 180 mA","cmc":"0,039 %"},{"name":"40 Hz až 1 kHz","range":"130 mA až 180 mA","cmc":"0,019 %"},{"name":"1 kHz až 5 kHz","range":"130 mA až 180 mA","cmc":"0,092 %"},{"name":"5 kHz až 10 kHz","range":"130 mA až 180 mA","cmc":"0,24 %"},{"name":"10 Hz až 20 Hz","range":"180 mA až 220 mA","cmc":"0,073 %"},{"name":"20 Hz až 40 Hz","range":"180 mA až 220 mA","cmc":"0,038 %"},{"name":"40 Hz až 1 kHz","range":"180 mA až 220 mA","cmc":"0,019 %"},{"name":"1 kHz až 5 kHz","range":"180 mA až 220 mA","cmc":"0,084 %"},{"name":"5 kHz až 10 kHz","range":"180 mA až 220 mA","cmc":"0,21 %"},{"name":"20 Hz až 1 kHz","range":"220 mA až 300 mA","cmc":"0,082 %"},{"name":"1 kHz až 5 kHz","range":"220 mA až 300 mA","cmc":"0,12 %"},{"name":"5 kHz až 10 kHz","range":"220 mA až 300 mA","cmc":"0,93 %"},{"name":"20 Hz až 1 kHz","range":"300 mA až 400 mA","cmc":"0,078 %"},{"name":"1 kHz až 5 kHz","range":"300 mA až 400 mA","cmc":"0,11 %"},{"name":"5 kHz až 10 kHz","range":"300 mA až 400 mA","cmc":"0,91 %"},{"name":"20 Hz až 1 kHz","range":"400 mA až 500 mA","cmc":"0,075 %"},{"name":"1 kHz až 5 kHz","range":"400 mA až 500 mA","cmc":"0,098 %"},{"name":"5 kHz až 10 kHz","range":"400 mA až 500 mA","cmc":"0,90 %"},{"name":"20 Hz až 1 kHz","range":"500 mA až 600 mA","cmc":"0,074 %"},{"name":"1 kHz až 5 kHz","range":"500 mA až 600 mA","cmc":"0,094 %"},{"name":"5 kHz až 10 kHz","range":"500 mA až 600 mA","cmc":"0,89 %"},{"name":"20 Hz až 1 kHz","range":"600 mA až 1 A","cmc":"0,072 %"},{"name":"1 kHz až 5 kHz","range":"600 mA až 1 A","cmc":"0,092 %"},{"name":"5 kHz až 10 kHz","range":"600 mA až 1 A","cmc":"0,89 %"},{"name":"20 Hz až 1 kHz","range":"1 A až 2,2 A","cmc":"0,070 %"},{"name":"1 kHz až 5 kHz","range":"1 A až 2,2 A","cmc":"0,086 %"},{"name":"5 kHz až 10 kHz","range":"1 A až 2,2 A","cmc":"0,88 %"},{"name":"10 Hz až 1 kHz","range":"2,2 A až 3 A","cmc":"0,16 %"},{"name":"1 kHz až 5 kHz","range":"2,2 A až 3 A","cmc":"0,22 %"},{"name":"5 kHz až 10 kHz","range":"2,2 A až 3 A","cmc":"0,60 %"},{"name":"10 Hz až 1 kHz","range":"3 A až 5 A","cmc":"0,14 %"},{"name":"1 kHz až 5 kHz","range":"3 A až 5 A","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"3 A až 5 A","cmc":"0,51 %"},{"name":"10 Hz až 1 kHz","range":"5 A až 11 A","cmc":"0,13 %"},{"name":"1 kHz až 5 kHz","range":"5 A až 11 A","cmc":"0,18 %"},{"name":"5 kHz až 10 kHz","range":"5 A až 11 A","cmc":"0,42 %"},{"name":"30 Hz až 45 Hz","range":"11 A až 15 A","cmc":"0,23 %"},{"name":"45 Hz až 100 Hz","range":"11 A až 15 A","cmc":"0,12 %"},{"name":"100 Hz až 1 kHz","range":"11 A až 15 A","cmc":"0,52 %"},{"name":"30 Hz až 45 Hz","range":"15 A až 25 A","cmc":"0,22 %"},{"name":"45 Hz až 100 Hz","range":"15 A až 25 A","cmc":"0,12 %"},{"name":"100 Hz až 1 kHz","range":"15 A až 25 A","cmc":"0,51 %"},{"name":"30 Hz až 45 Hz","range":"25 A až 30 A","cmc":"0,21 %"},{"name":"45 Hz až 100 Hz","range":"25 A až 30 A","cmc":"0,11 %"},{"name":"100 Hz až 1 kHz","range":"25 A až 30 A","cmc":"0,49 %"},{"name":"50 Hz","range":"2,2 A až 3 A","cmc":"0,12 %"},{"name":"50 Hz","range":"3 A až 4 A","cmc":"0,095 %"},{"name":"50 Hz","range":"4 A až 5 A","cmc":"0,084 %"},{"name":"50 Hz","range":"5 A až 6 A","cmc":"0,077 %"},{"name":"50 Hz","range":"6 A až 7 A","cmc":"0,073 %"},{"name":"50 Hz","range":"7 A až 8 A","cmc":"0,070 %"},{"name":"50 Hz","range":"8 A až 10 A","cmc":"0,067 %"},{"name":"50 Hz","range":"10 A až 11 A","cmc":"0,064 %"},{"name":"50 Hz","range":"11 A až 15 A","cmc":"0,10 %"},{"name":"50 Hz","range":"15 A až 20 A","cmc":"0,081 %"},{"name":"50 Hz","range":"20 A až 90 A","cmc":"0,090 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 20 Hz od 10 µA do 20 µA CMC 40 nA\n20 Hz do 40 Hz od 10 µA do 20 µA CMC 28 nA\n40 Hz do 1 kHz od 10 µA do 20 µA CMC 18 nA\n1 kHz do 5 kHz od 10 µA do 20 µA CMC 47 nA\n5 kHz do 10 kHz od 10 µA do 20 µA CMC 97 nA\n10 Hz do 20 Hz od 20 µA do 30 µA CMC 0,20 %\n20 Hz do 40 Hz od 20 µA do 30 µA CMC 0,14 %\n40 Hz do 1 kHz od 20 µA do 30 µA CMC 0,095 %\n1 kHz do 5 kHz od 20 µA do 30 µA CMC 0,26 %\n5 kHz do 10 kHz od 20 µA do 30 µA CMC 0,57 %\n10 Hz do 20 Hz od 30 µA do 40 µA CMC 0,16 %\n20 Hz do 40 Hz od 30 µA do 40 µA CMC 0,11 %\n40 Hz do 1 kHz od 30 µA do 40 µA CMC 0,069 %\n1 kHz do 5 kHz od 30 µA do 40 µA CMC 0,20 %\n5 kHz do 10 kHz od 30 µA do 40 µA CMC 0,43 %\n10 Hz do 20 Hz od 40 µA do 50 µA CMC 0,14 %\n20 Hz do 40 Hz od 40 µA do 50 µA CMC 0,086 %\n40 Hz do 1 kHz od 40 µA do 50 µA CMC 0,055 %\n1 kHz do 5 kHz od 40 µA do 50 µA CMC 0,17 %\n5 kHz do 10 kHz od 40 µA do 50 µA CMC 0,37 %\n10 Hz do 20 Hz od 50 µA do 60 µA CMC 0,13 %\n20 Hz do 40 Hz od 50 µA do 60 µA CMC 0,076 %\n40 Hz do 1 kHz od 50 µA do 60 µA CMC 0,048 %\n1 kHz do 5 kHz od 50 µA do 60 µA CMC 0,15 %\n5 kHz do 10 kHz od 50 µA do 60 µA CMC 0,33 %\n10 Hz do 20 Hz od 60 µA do 80 µA CMC 0,12 %\n20 Hz do 40 Hz od 60 µA do 80 µA CMC 0,070 %\n40 Hz do 1 kHz od 60 µA do 80 µA CMC 0,042 %\n1 kHz do 5 kHz od 60 µA do 80 µA CMC 0,13 %\n5 kHz do 10 kHz od 60 µA do 80 µA CMC 0,30 %\n10 Hz do 20 Hz od 80 µA do 100 µA CMC 0,099 %\n20 Hz do 40 Hz od 80 µA do 100 µA CMC 0,061 %\n40 Hz do 1 kHz od 80 µA do 100 µA CMC 0,036 %\n1 kHz do 5 kHz od 80 µA do 100 µA CMC 0,12 %\n5 kHz do 10 kHz od 80 µA do 100 µA CMC 0,27 %\n10 Hz do 20 Hz od 100 µA do 130 µA CMC 0,096 %\n20 Hz do 40 Hz od 100 µA do 130 µA CMC 0,056 %\n40 Hz do 1 kHz od 100 µA do 130 µA CMC 0,032 %\n1 kHz do 5 kHz od 100 µA do 130 µA CMC 0,11 %\n5 kHz do 10 kHz od 100 µA do 130 µA CMC 0,25 %\n10 Hz do 20 Hz od 130 µA do 180 µA CMC 0,090 %\n20 Hz do 40 Hz od 130 µA do 180 µA CMC 0,052 %\n40 Hz do 1 kHz od 130 µA do 180 µA CMC 0,029 %\n1 kHz do 5 kHz od 130 µA do 180 µA CMC 0,092 %\n5 kHz do 10 kHz od 130 µA do 180 µA CMC 0,23 %\n10 Hz do 20 Hz od 180 µA do 220 µA CMC 0,085 %\n20 Hz do 40 Hz od 180 µA do 220 µA CMC 0,048 %\n40 Hz do 1 kHz od 180 µA do 220 µA CMC 0,025 %\n1 kHz do 5 kHz od 180 µA do 220 µA CMC 0,084 %\n5 kHz do 10 kHz od 180 µA do 220 µA CMC 0,21 %\n10 Hz do 20 Hz od 220 µA do 300 µA CMC 0,089 %\n20 Hz do 40 Hz od 220 µA do 300 µA CMC 0,052 %\n40 Hz do 1 kHz od 220 µA do 300 µA CMC 0,032 %\n1 kHz do 5 kHz od 220 µA do 300 µA CMC 0,25 %\n5 kHz do 10 kHz od 220 µA do 300 µA CMC 0,53 %\n10 Hz do 20 Hz od 300 µA do 400 µA CMC 0,084 %\n20 Hz do 40 Hz od 300 µA do 400 µA CMC 0,048 %\n40 Hz do 1 kHz od 300 µA do 400 µA CMC 0,028 %\n1 kHz do 5 kHz od 300 µA do 400 µA CMC 0,20 %\n5 kHz do 10 kHz od 300 µA do 400 µA CMC 0,43 %\n10 Hz do 20 Hz od 400 µA do 500 µA CMC 0,081 %\n20 Hz do 40 Hz od 400 µA do 500 µA CMC 0,045 %\n40 Hz do 1 kHz od 400 µA do 500 µA CMC 0,025 %\n1 kHz do 5 kHz od 400 µA do 500 µA CMC 0,17 %\n5 kHz do 10 kHz od 400 µA do 500 µA CMC 0,37 %\n10 Hz do 20 Hz od 500 µA do 600 µA CMC 0,079 %\n20 Hz do 40 Hz od 500 µA do 600 µA CMC 0,044 %\n40 Hz do 1 kHz od 500 µA do 600 µA CMC 0,023 %\n1 kHz do 5 kHz od 500 µA do 600 µA CMC 0,15 %\n5 kHz do 10 kHz od 500 µA do 600 µA CMC 0,33 %\n10 Hz do 20 Hz od 600 µA do 800 µA CMC 0,078 %\n20 Hz do 40 Hz od 600 µA do 800 µA CMC 0,043 %\n40 Hz do 1 kHz od 600 µA do 800 µA CMC 0,022 %\n1 kHz do 5 kHz od 600 µA do 800 µA CMC 0,13 %\n5 kHz do 10 kHz od 600 µA do 800 µA CMC 0,30 %\n10 Hz do 20 Hz od 800 µA do 1 mA CMC 0,076 %\n20 Hz do 40 Hz od 800 µA do 1 mA CMC 0,041 %\n40 Hz do 1 kHz od 800 µA do 1 mA CMC 0,021 %\n1 kHz do 5 kHz od 800 µA do 1 mA CMC 0,12 %\n5 kHz do 10 kHz od 800 µA do 1 mA CMC 0,27 %\n10 Hz do 20 Hz od 1 mA do 1,3 mA CMC 0,075 %\n20 Hz do 40 Hz od 1 mA do 1,3 mA CMC 0,040 %\n40 Hz do 1 kHz od 1 mA do 1,3 mA CMC 0,020 %\n1 kHz do 5 kHz od 1 mA do 1,3 mA CMC 0,11 %\n5 kHz do 10 kHz od 1 mA do 1,3 mA CMC 0,25 %\n10 Hz do 20 Hz od 1,3 mA do 1,8 mA CMC 0,074 %\n20 Hz do 40 Hz od 1,3 mA do 1,8 mA CMC 0,039 %\n40 Hz do 1 kHz od 1,3 mA do 1,8 mA CMC 0,019 %\n1 kHz do 5 kHz od 1,3 mA do 1,8 mA CMC 0,092 %\n5 kHz do 10 kHz od 1,3 mA do 1,8 mA CMC 0,23 %\n10 Hz do 20 Hz od 1,8 mA do 2,2 mA CMC 0,073 %\n20 Hz do 40 Hz od 1,8 mA do 2,2 mA CMC 0,074 %\n40 Hz do 1 kHz od 1,8 mA do 2,2 mA CMC 0,019 %\n1 kHz do 5 kHz od 1,8 mA do 2,2 mA CMC 0,084 %\n5 kHz do 10 kHz od 1,8 mA do 2,2 mA CMC 0,21 %\n10 Hz do 20 Hz od 2,2 mA do 3 mA CMC 0,089 %\n20 Hz do 40 Hz od 2,2 mA do 3 mA CMC 0,052 %\n40 Hz do 1 kHz od 2,2 mA do 3 mA CMC 0,032 %\n1 kHz do 5 kHz od 2,2 mA do 3 mA CMC 0,25 %\n5 kHz do 10 kHz od 2,2 mA do 3 mA CMC 0,53 %\n10 Hz do 20 Hz od 3 mA do 4 mA CMC 0,084 %\n20 Hz do 40 Hz od 3 mA do 4 mA CMC 0,048 %\n40 Hz do 1 kHz od 3 mA do 4 mA CMC 0,028 %\n1 kHz do 5 kHz od 3 mA do 4 mA CMC 0,20 %\n5 kHz do 10 kHz od 3 mA do 4 mA CMC 0,43 %\n10 Hz do 20 Hz od 4 mA do 5 mA CMC 0,081 %\n20 Hz do 40 Hz od 4 mA do 5 mA CMC 0,045 %\n40 Hz do 1 kHz od 4 mA do 5 mA CMC 0,025 %\n1 kHz do 5 kHz od 4 mA do 5 mA CMC 0,17 %\n5 kHz do 10 kHz od 4 mA do 5 mA CMC 0,37 %\n10 Hz do 20 Hz od 5 mA do 6 mA CMC 0,079 %\n20 Hz do 40 Hz od 5 mA do 6 mA CMC 0,043 %\n40 Hz do 1 kHz od 5 mA do 6 mA CMC 0,023 %\n1 kHz do 5 kHz od 5 mA do 6 mA CMC 0,15 %\n5 kHz do 10 kHz od 5 mA do 6 mA CMC 0,33 %\n10 Hz do 20 Hz od 6 mA do 8 mA CMC 0,078 %\n20 Hz do 40 Hz od 6 mA do 8 mA CMC 0,042 %\n40 Hz do 1 kHz od 6 mA do 8 mA CMC 0,022 %\n1 kHz do 5 kHz od 6 mA do 8 mA CMC 0,13 %\n5 kHz do 10 kHz od 6 mA do 8 mA CMC 0,30 %\n10 Hz do 20 Hz od 8 mA do 10 mA CMC 0,076 %\n20 Hz do 40 Hz od 8 mA do 10 mA CMC 0,041 %\n40 Hz do 1 kHz od 8 mA do 10 mA CMC 0,021 %\n1 kHz do 5 kHz od 8 mA do 10 mA CMC 0,12 %\n5 kHz do 10 kHz od 8 mA do 10 mA CMC 0,27 %\n10 Hz do 20 Hz od 10 mA do 13 mA CMC 0,075 %\n20 Hz do 40 Hz od 10 mA do 13 mA CMC 0,040 %\n40 Hz do 1 kHz od 10 mA do 13 mA CMC 0,020 %\n1 kHz do 5 kHz od 10 mA do 13 mA CMC 0,11 %\n5 kHz do 10 kHz od 10 mA do 13 mA CMC 0,25 %\n10 Hz do 20 Hz od 13 mA do 18 mA CMC 0,074 %\n20 Hz do 40 Hz od 13 mA do 18 mA CMC 0,039 %\n40 Hz do 1 kHz od 13 mA do 18 mA CMC 0,019 %\n1 kHz do 5 kHz od 13 mA do 18 mA CMC 0,092 %\n5 kHz do 10 kHz od 13 mA do 18 mA CMC 0,23 %\n10 Hz do 20 Hz od 18 mA do 22 mA CMC 0,073 %\n20 Hz do 40 Hz od 18 mA do 22 mA CMC 0,039 %\n40 Hz do 1 kHz od 18 mA do 22 mA CMC 0,019 %\n1 kHz do 5 kHz od 18 mA do 22 mA CMC 0,084 %\n5 kHz do 10 kHz od 18 mA do 22 mA CMC 0,21 %\n10 Hz do 20 Hz od 22 mA do 30 mA CMC 0,089 %\n20 Hz do 40 Hz od 22 mA do 30 mA CMC 0,052 %\n40 Hz do 1 kHz od 22 mA do 30 mA CMC 0,032 %\n1 kHz do 5 kHz od 22 mA do 30 mA CMC 0,25 %\n5 kHz do 10 kHz od 22 mA do 30 mA CMC 0,53 %\n10 Hz do 20 Hz od 30 mA do 40 mA CMC 0,084 %\n20 Hz do 40 Hz od 30 mA do 40 mA CMC 0,048 %\n40 Hz do 1 kHz od 30 mA do 40 mA CMC 0,028 %\n1 kHz do 5 kHz od 30 mA do 40 mA CMC 0,20 %\n5 kHz do 10 kHz od 30 mA do 40 mA CMC 0,43 %\n10 Hz do 20 Hz od 40 mA do 50 mA CMC 0,081 %\n20 Hz do 40 Hz od 40 mA do 50 mA CMC 0,045 %\n40 Hz do 1 kHz od 40 mA do 50 mA CMC 0,025 %\n1 kHz do 5 kHz od 40 mA do 50 mA CMC 0,17 %\n5 kHz do 10 kHz od 40 mA do 50 mA CMC 0,37 %\n10 Hz do 20 Hz od 50 mA do 60 mA CMC 0,079 %\n20 Hz do 40 Hz od 50 mA do 60 mA CMC 0,043 %\n40 Hz do 1 kHz od 50 mA do 60 mA CMC 0,023 %\n1 kHz do 5 kHz od 50 mA do 60 mA CMC 0,15 %\n5 kHz do 10 kHz od 50 mA do 60 mA CMC 0,33 %\n10 Hz do 20 Hz od 60 mA do 80 mA CMC 0,078 %\n20 Hz do 40 Hz od 60 mA do 80 mA CMC 0,042 %\n40 Hz do 1 kHz od 60 mA do 80 mA CMC 0,022 %\n1 kHz do 5 kHz od 60 mA do 80 mA CMC 0,13 %\n5 kHz do 10 kHz od 60 mA do 80 mA CMC 0,30 %\n10 Hz do 20 Hz od 80 mA do 100 mA CMC 0,076 %\n20 Hz do 40 Hz od 80 mA do 100 mA CMC 0,041 %\n40 Hz do 1 kHz od 80 mA do 100 mA CMC 0,021 %\n1 kHz do 5 kHz od 80 mA do 100 mA CMC 0,12 %\n5 kHz do 10 kHz od 80 mA do 100 mA CMC 0,27 %\n10 Hz do 20 Hz od 100 mA do 130 mA CMC 0,075 %\n20 Hz do 40 Hz od 100 mA do 130 mA CMC 0,040 %\n40 Hz do 1 kHz od 100 mA do 130 mA CMC 0,020 %\n1 kHz do 5 kHz od 100 mA do 130 mA CMC 0,11 %\n5 kHz do 10 kHz od 100 mA do 130 mA CMC 0,25 %\n10 Hz do 20 Hz od 130 mA do 180 mA CMC 0,074 %\n20 Hz do 40 Hz od 130 mA do 180 mA CMC 0,039 %\n40 Hz do 1 kHz od 130 mA do 180 mA CMC 0,019 %\n1 kHz do 5 kHz od 130 mA do 180 mA CMC 0,092 %\n5 kHz do 10 kHz od 130 mA do 180 mA CMC 0,24 %\n10 Hz do 20 Hz od 180 mA do 220 mA CMC 0,073 %\n20 Hz do 40 Hz od 180 mA do 220 mA CMC 0,038 %\n40 Hz do 1 kHz od 180 mA do 220 mA CMC 0,019 %\n1 kHz do 5 kHz od 180 mA do 220 mA CMC 0,084 %\n5 kHz do 10 kHz od 180 mA do 220 mA CMC 0,21 %\n20 Hz do 1 kHz od 220 mA do 300 mA CMC 0,082 %\n1 kHz do 5 kHz od 220 mA do 300 mA CMC 0,12 %\n5 kHz do 10 kHz od 220 mA do 300 mA CMC 0,93 %\n20 Hz do 1 kHz od 300 mA do 400 mA CMC 0,078 %\n1 kHz do 5 kHz od 300 mA do 400 mA CMC 0,11 %\n5 kHz do 10 kHz od 300 mA do 400 mA CMC 0,91 %\n20 Hz do 1 kHz od 400 mA do 500 mA CMC 0,075 %\n1 kHz do 5 kHz od 400 mA do 500 mA CMC 0,098 %\n5 kHz do 10 kHz od 400 mA do 500 mA CMC 0,90 %\n20 Hz do 1 kHz od 500 mA do 600 mA CMC 0,074 %\n1 kHz do 5 kHz od 500 mA do 600 mA CMC 0,094 %\n5 kHz do 10 kHz od 500 mA do 600 mA CMC 0,89 %\n20 Hz do 1 kHz od 600 mA do 1 A CMC 0,072 %\n1 kHz do 5 kHz od 600 mA do 1 A CMC 0,092 %\n5 kHz do 10 kHz od 600 mA do 1 A CMC 0,89 %\n20 Hz do 1 kHz od 1 A do 2,2 A CMC 0,070 %\n1 kHz do 5 kHz od 1 A do 2,2 A CMC 0,086 %\n5 kHz do 10 kHz od 1 A do 2,2 A CMC 0,88 %\n10 Hz do 1 kHz od 2,2 A do 3 A CMC 0,16 %\n1 kHz do 5 kHz od 2,2 A do 3 A CMC 0,22 %\n5 kHz do 10 kHz od 2,2 A do 3 A CMC 0,60 %\n10 Hz do 1 kHz od 3 A do 5 A CMC 0,14 %\n1 kHz do 5 kHz od 3 A do 5 A CMC 0,20 %\n5 kHz do 10 kHz od 3 A do 5 A CMC 0,51 %\n10 Hz do 1 kHz od 5 A do 11 A CMC 0,13 %\n1 kHz do 5 kHz od 5 A do 11 A CMC 0,18 %\n5 kHz do 10 kHz od 5 A do 11 A CMC 0,42 %\n30 Hz do 45 Hz od 11 A do 15 A CMC 0,23 %\n45 Hz do 100 Hz od 11 A do 15 A CMC 0,12 %\n100 Hz do 1 kHz od 11 A do 15 A CMC 0,52 %\n30 Hz do 45 Hz od 15 A do 25 A CMC 0,22 %\n45 Hz do 100 Hz od 15 A do 25 A CMC 0,12 %\n100 Hz do 1 kHz od 15 A do 25 A CMC 0,51 %\n30 Hz do 45 Hz od 25 A do 30 A CMC 0,21 %\n45 Hz do 100 Hz od 25 A do 30 A CMC 0,11 %\n100 Hz do 1 kHz od 25 A do 30 A CMC 0,49 %\n50 Hz od 2,2 A do 3 A CMC 0,12 %\n50 Hz od 3 A do 4 A CMC 0,095 %\n50 Hz od 4 A do 5 A CMC 0,084 %\n50 Hz od 5 A do 6 A CMC 0,077 %\n50 Hz od 6 A do 7 A CMC 0,073 %\n50 Hz od 7 A do 8 A CMC 0,070 %\n50 Hz od 8 A do 10 A CMC 0,067 %\n50 Hz od 10 A do 11 A CMC 0,064 %\n50 Hz od 11 A do 15 A CMC 0,10 %\n50 Hz od 15 A do 20 A CMC 0,081 %\n50 Hz od 20 A do 90 A CMC 0,090 %\nBezpośrednie generowanie kalibratorem","reference":"TP4, TP21","norm_bases":["TP4","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / Mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 10 Hz do 20 Hz od 10 µA do 20 µA CMC 40 nA 20 Hz do 40 Hz od 10 µA do 20 µA CMC 28 nA 40 Hz do 1 kHz od 10 µA do 20 µA CMC 18 nA 1 kHz do 5 kHz od 10 µA do 20 µA CMC 47 nA 5 kHz do 10 kHz od 10 µA do 20 µA CMC 97 nA 10 Hz do 20 Hz od 20 µA do 30 µA CMC 0,20 % 20 Hz do 40 Hz od 20 µA do 30 µA CMC 0,14 % 40 Hz do 1 kHz od 20 µA do 30 µA CMC 0,095 % 1 kHz do 5 kHz od 20 µA do 30 µA CMC 0,26 % 5 kHz do 10 kHz od 20 µA do 30 µA CMC 0,57 % 10 Hz do 20 Hz od 30 µA do 40 µA CMC 0,16 % 20 Hz do 40 Hz od 30 µA do 40 µA CMC 0,11 % 40 Hz do 1 kHz od 30 µA do 40 µA CMC 0,069 % 1 kHz do 5 kHz od 30 µA do 40 µA CMC 0,20 % 5 kHz do 10 kHz od 30 µA do 40 µA CMC 0,43 % 10 Hz do 20 Hz od 40 µA do 50 µA CMC 0,14 % 20 Hz do 40 Hz od 40 µA do 50 µA CMC 0,086 % 40 Hz do 1 kHz od 40 µA do 50 µA CMC 0,055 % 1 kHz do 5 kHz od 40 µA do 50 µA CMC 0,17 % 5 kHz do 10 kHz od 40 µA do 50 µA CMC 0,37 % 10 Hz do 20 Hz od 50 µA do 60 µA CMC 0,13 % 20 Hz do 40 Hz od 50 µA do 60 µA CMC 0,076 % 40 Hz do 1 kHz od 50 µA do 60 µA CMC 0,048 % 1 kHz do 5 kHz od 50 µA do 60 µA CMC 0,15 % 5 kHz do 10 kHz od 50 µA do 60 µA CMC 0,33 % 10 Hz do 20 Hz od 60 µA do 80 µA CMC 0,12 % 20 Hz do 40 Hz od 60 µA do 80 µA CMC 0,070 % 40 Hz do 1 kHz od 60 µA do 80 µA CMC 0,042 % 1 kHz do 5 kHz od 60 µA do 80 µA CMC 0,13 % 5 kHz do 10 kHz od 60 µA do 80 µA CMC 0,30 % 10 Hz do 20 Hz od 80 µA do 100 µA CMC 0,099 % 20 Hz do 40 Hz od 80 µA do 100 µA CMC 0,061 % 40 Hz do 1 kHz od 80 µA do 100 µA CMC 0,036 % 1 kHz do 5 kHz od 80 µA do 100 µA CMC 0,12 % 5 kHz do 10 kHz od 80 µA do 100 µA CMC 0,27 % 10 Hz do 20 Hz od 100 µA do 130 µA CMC 0,096 % 20 Hz do 40 Hz od 100 µA do 130 µA CMC 0,056 % 40 Hz do 1 kHz od 100 µA do 130 µA CMC 0,032 % 1 kHz do 5 kHz od 100 µA do 130 µA CMC 0,11 % 5 kHz do 10 kHz od 100 µA do 130 µA CMC 0,25 % 10 Hz do 20 Hz od 130 µA do 180 µA CMC 0,090 % 20 Hz do 40 Hz od 130 µA do 180 µA CMC 0,052 % 40 Hz do 1 kHz od 130 µA do 180 µA CMC 0,029 % 1 kHz do 5 kHz od 130 µA do 180 µA CMC 0,092 % 5 kHz do 10 kHz od 130 µA do 180 µA CMC 0,23 % 10 Hz do 20 Hz od 180 µA do 220 µA CMC 0,085 % 20 Hz do 40 Hz od 180 µA do 220 µA CMC 0,048 % 40 Hz do 1 kHz od 180 µA do 220 µA CMC 0,025 % 1 kHz do 5 kHz od 180 µA do 220 µA CMC 0,084 % 5 kHz do 10 kHz od 180 µA do 220 µA CMC 0,21 % 10 Hz do 20 Hz od 220 µA do 300 µA CMC 0,089 % 20 Hz do 40 Hz od 220 µA do 300 µA CMC 0,052 % 40 Hz do 1 kHz od 220 µA do 300 µA CMC 0,032 % 1 kHz do 5 kHz od 220 µA do 300 µA CMC 0,25 % 5 kHz do 10 kHz od 220 µA do 300 µA CMC 0,53 % 10 Hz do 20 Hz od 300 µA do 400 µA CMC 0,084 % 20 Hz do 40 Hz od 300 µA do 400 µA CMC 0,048 % 40 Hz do 1 kHz od 300 µA do 400 µA CMC 0,028 % 1 kHz do 5 kHz od 300 µA do 400 µA CMC 0,20 % 5 kHz do 10 kHz od 300 µA do 400 µA CMC 0,43 % 10 Hz do 20 Hz od 400 µA do 500 µA CMC 0,081 % 20 Hz do 40 Hz od 400 µA do 500 µA CMC 0,045 % 40 Hz do 1 kHz od 400 µA do 500 µA CMC 0,025 % 1 kHz do 5 kHz od 400 µA do 500 µA CMC 0,17 % 5 kHz do 10 kHz od 400 µA do 500 µA CMC 0,37 % 10 Hz do 20 Hz od 500 µA do 600 µA CMC 0,079 % 20 Hz do 40 Hz od 500 µA do 600 µA CMC 0,044 % 40 Hz do 1 kHz od 500 µA do 600 µA CMC 0,023 % 1 kHz do 5 kHz od 500 µA do 600 µA CMC 0,15 % 5 kHz do 10 kHz od 500 µA do 600 µA CMC 0,33 % 10 Hz do 20 Hz od 600 µA do 800 µA CMC 0,078 % 20 Hz do 40 Hz od 600 µA do 800 µA CMC 0,043 % 40 Hz do 1 kHz od 600 µA do 800 µA CMC 0,022 % 1 kHz do 5 kHz od 600 µA do 800 µA CMC 0,13 % 5 kHz do 10 kHz od 600 µA do 800 µA CMC 0,30 % 10 Hz do 20 Hz od 800 µA do 1 mA CMC 0,076 % 20 Hz do 40 Hz od 800 µA do 1 mA CMC 0,041 % 40 Hz do 1 kHz od 800 µA do 1 mA CMC 0,021 % 1 kHz do 5 kHz od 800 µA do 1 mA CMC 0,12 % 5 kHz do 10 kHz od 800 µA do 1 mA CMC 0,27 % 10 Hz do 20 Hz od 1 mA do 1,3 mA CMC 0,075 % 20 Hz do 40 Hz od 1 mA do 1,3 mA CMC 0,040 % 40 Hz do 1 kHz od 1 mA do 1,3 mA CMC 0,020 % 1 kHz do 5 kHz od 1 mA do 1,3 mA CMC 0,11 % 5 kHz do 10 kHz od 1 mA do 1,3 mA CMC 0,25 % 10 Hz do 20 Hz od 1,3 mA do 1,8 mA CMC 0,074 % 20 Hz do 40 Hz od 1,3 mA do 1,8 mA CMC 0,039 % 40 Hz do 1 kHz od 1,3 mA do 1,8 mA CMC 0,019 % 1 kHz do 5 kHz od 1,3 mA do 1,8 mA CMC 0,092 % 5 kHz do 10 kHz od 1,3 mA do 1,8 mA CMC 0,23 % 10 Hz do 20 Hz od 1,8 mA do 2,2 mA CMC 0,073 % 20 Hz do 40 Hz od 1,8 mA do 2,2 mA CMC 0,074 % 40 Hz do 1 kHz od 1,8 mA do 2,2 mA CMC 0,019 % 1 kHz do 5 kHz od 1,8 mA do 2,2 mA CMC 0,084 % 5 kHz do 10 kHz od 1,8 mA do 2,2 mA CMC 0,21 % 10 Hz do 20 Hz od 2,2 mA do 3 mA CMC 0,089 % 20 Hz do 40 Hz od 2,2 mA do 3 mA CMC 0,052 % 40 Hz do 1 kHz od 2,2 mA do 3 mA CMC 0,032 % 1 kHz do 5 kHz od 2,2 mA do 3 mA CMC 0,25 % 5 kHz do 10 kHz od 2,2 mA do 3 mA CMC 0,53 % 10 Hz do 20 Hz od 3 mA do 4 mA CMC 0,084 % 20 Hz do 40 Hz od 3 mA do 4 mA CMC 0,048 % 40 Hz do 1 kHz od 3 mA do 4 mA CMC 0,028 % 1 kHz do 5 kHz od 3 mA do 4 mA CMC 0,20 % 5 kHz do 10 kHz od 3 mA do 4 mA CMC 0,43 % 10 Hz do 20 Hz od 4 mA do 5 mA CMC 0,081 % 20 Hz do 40 Hz od 4 mA do 5 mA CMC 0,045 % 40 Hz do 1 kHz od 4 mA do 5 mA CMC 0,025 % 1 kHz do 5 kHz od 4 mA do 5 mA CMC 0,17 % 5 kHz do 10 kHz od 4 mA do 5 mA CMC 0,37 % 10 Hz do 20 Hz od 5 mA do 6 mA CMC 0,079 % 20 Hz do 40 Hz od 5 mA do 6 mA CMC 0,043 % 40 Hz do 1 kHz od 5 mA do 6 mA CMC 0,023 % 1 kHz do 5 kHz od 5 mA do 6 mA CMC 0,15 % 5 kHz do 10 kHz od 5 mA do 6 mA CMC 0,33 % 10 Hz do 20 Hz od 6 mA do 8 mA CMC 0,078 % 20 Hz do 40 Hz od 6 mA do 8 mA CMC 0,042 % 40 Hz do 1 kHz od 6 mA do 8 mA CMC 0,022 % 1 kHz do 5 kHz od 6 mA do 8 mA CMC 0,13 % 5 kHz do 10 kHz od 6 mA do 8 mA CMC 0,30 % 10 Hz do 20 Hz od 8 mA do 10 mA CMC 0,076 % 20 Hz do 40 Hz od 8 mA do 10 mA CMC 0,041 % 40 Hz do 1 kHz od 8 mA do 10 mA CMC 0,021 % 1 kHz do 5 kHz od 8 mA do 10 mA CMC 0,12 % 5 kHz do 10 kHz od 8 mA do 10 mA CMC 0,27 % 10 Hz do 20 Hz od 10 mA do 13 mA CMC 0,075 % 20 Hz do 40 Hz od 10 mA do 13 mA CMC 0,040 % 40 Hz do 1 kHz od 10 mA do 13 mA CMC 0,020 % 1 kHz do 5 kHz od 10 mA do 13 mA CMC 0,11 % 5 kHz do 10 kHz od 10 mA do 13 mA CMC 0,25 % 10 Hz do 20 Hz od 13 mA do 18 mA CMC 0,074 % 20 Hz do 40 Hz od 13 mA do 18 mA CMC 0,039 % 40 Hz do 1 kHz od 13 mA do 18 mA CMC 0,019 % 1 kHz do 5 kHz od 13 mA do 18 mA CMC 0,092 % 5 kHz do 10 kHz od 13 mA do 18 mA CMC 0,23 % 10 Hz do 20 Hz od 18 mA do 22 mA CMC 0,073 % 20 Hz do 40 Hz od 18 mA do 22 mA CMC 0,039 % 40 Hz do 1 kHz od 18 mA do 22 mA CMC 0,019 % 1 kHz do 5 kHz od 18 mA do 22 mA CMC 0,084 % 5 kHz do 10 kHz od 18 mA do 22 mA CMC 0,21 % 10 Hz do 20 Hz od 22 mA do 30 mA CMC 0,089 % 20 Hz do 40 Hz od 22 mA do 30 mA CMC 0,052 % 40 Hz do 1 kHz od 22 mA do 30 mA CMC 0,032 % 1 kHz do 5 kHz od 22 mA do 30 mA CMC 0,25 % 5 kHz do 10 kHz od 22 mA do 30 mA CMC 0,53 % 10 Hz do 20 Hz od 30 mA do 40 mA CMC 0,084 % 20 Hz do 40 Hz od 30 mA do 40 mA CMC 0,048 % 40 Hz do 1 kHz od 30 mA do 40 mA CMC 0,028 % 1 kHz do 5 kHz od 30 mA do 40 mA CMC 0,20 % 5 kHz do 10 kHz od 30 mA do 40 mA CMC 0,43 % 10 Hz do 20 Hz od 40 mA do 50 mA CMC 0,081 % 20 Hz do 40 Hz od 40 mA do 50 mA CMC 0,045 % 40 Hz do 1 kHz od 40 mA do 50 mA CMC 0,025 % 1 kHz do 5 kHz od 40 mA do 50 mA CMC 0,17 % 5 kHz do 10 kHz od 40 mA do 50 mA CMC 0,37 % 10 Hz do 20 Hz od 50 mA do 60 mA CMC 0,079 % 20 Hz do 40 Hz od 50 mA do 60 mA CMC 0,043 % 40 Hz do 1 kHz od 50 mA do 60 mA CMC 0,023 % 1 kHz do 5 kHz od 50 mA do 60 mA CMC 0,15 % 5 kHz do 10 kHz od 50 mA do 60 mA CMC 0,33 % 10 Hz do 20 Hz od 60 mA do 80 mA CMC 0,078 % 20 Hz do 40 Hz od 60 mA do 80 mA CMC 0,042 % 40 Hz do 1 kHz od 60 mA do 80 mA CMC 0,022 % 1 kHz do 5 kHz od 60 mA do 80 mA CMC 0,13 % 5 kHz do 10 kHz od 60 mA do 80 mA CMC 0,30 % 10 Hz do 20 Hz od 80 mA do 100 mA CMC 0,076 % 20 Hz do 40 Hz od 80 mA do 100 mA CMC 0,041 % 40 Hz do 1 kHz od 80 mA do 100 mA CMC 0,021 % 1 kHz do 5 kHz od 80 mA do 100 mA CMC 0,12 % 5 kHz do 10 kHz od 80 mA do 100 mA CMC 0,27 % 10 Hz do 20 Hz od 100 mA do 130 mA CMC 0,075 % 20 Hz do 40 Hz od 100 mA do 130 mA CMC 0,040 % 40 Hz do 1 kHz od 100 mA do 130 mA CMC 0,020 % 1 kHz do 5 kHz od 100 mA do 130 mA CMC 0,11 % 5 kHz do 10 kHz od 100 mA do 130 mA CMC 0,25 % 10 Hz do 20 Hz od 130 mA do 180 mA CMC 0,074 % 20 Hz do 40 Hz od 130 mA do 180 mA CMC 0,039 % 40 Hz do 1 kHz od 130 mA do 180 mA CMC 0,019 % 1 kHz do 5 kHz od 130 mA do 180 mA CMC 0,092 % 5 kHz do 10 kHz od 130 mA do 180 mA CMC 0,24 % 10 Hz do 20 Hz od 180 mA do 220 mA CMC 0,073 % 20 Hz do 40 Hz od 180 mA do 220 mA CMC 0,038 % 40 Hz do 1 kHz od 180 mA do 220 mA CMC 0,019 % 1 kHz do 5 kHz od 180 mA do 220 mA CMC 0,084 % 5 kHz do 10 kHz od 180 mA do 220 mA CMC 0,21 % 20 Hz do 1 kHz od 220 mA do 300 mA CMC 0,082 % 1 kHz do 5 kHz od 220 mA do 300 mA CMC 0,12 % 5 kHz do 10 kHz od 220 mA do 300 mA CMC 0,93 % 20 Hz do 1 kHz od 300 mA do 400 mA CMC 0,078 % 1 kHz do 5 kHz od 300 mA do 400 mA CMC 0,11 % 5 kHz do 10 kHz od 300 mA do 400 mA CMC 0,91 % 20 Hz do 1 kHz od 400 mA do 500 mA CMC 0,075 % 1 kHz do 5 kHz od 400 mA do 500 mA CMC 0,098 % 5 kHz do 10 kHz od 400 mA do 500 mA CMC 0,90 % 20 Hz do 1 kHz od 500 mA do 600 mA CMC 0,074 % 1 kHz do 5 kHz od 500 mA do 600 mA CMC 0,094 % 5 kHz do 10 kHz od 500 mA do 600 mA CMC 0,89 % 20 Hz do 1 kHz od 600 mA do 1 A CMC 0,072 % 1 kHz do 5 kHz od 600 mA do 1 A CMC 0,092 % 5 kHz do 10 kHz od 600 mA do 1 A CMC 0,89 % 20 Hz do 1 kHz od 1 A do 2,2 A CMC 0,070 % 1 kHz do 5 kHz od 1 A do 2,2 A CMC 0,086 % 5 kHz do 10 kHz od 1 A do 2,2 A CMC 0,88 % 10 Hz do 1 kHz od 2,2 A do 3 A CMC 0,16 % 1 kHz do 5 kHz od 2,2 A do 3 A CMC 0,22 % 5 kHz do 10 kHz od 2,2 A do 3 A CMC 0,60 % 10 Hz do 1 kHz od 3 A do 5 A CMC 0,14 % 1 kHz do 5 kHz od 3 A do 5 A CMC 0,20 % 5 kHz do 10 kHz od 3 A do 5 A CMC 0,51 % 10 Hz do 1 kHz od 5 A do 11 A CMC 0,13 % 1 kHz do 5 kHz od 5 A do 11 A CMC 0,18 % 5 kHz do 10 kHz od 5 A do 11 A CMC 0,42 % 30 Hz do 45 Hz od 11 A do 15 A CMC 0,23 % 45 Hz do 100 Hz od 11 A do 15 A CMC 0,12 % 100 Hz do 1 kHz od 11 A do 15 A CMC 0,52 % 30 Hz do 45 Hz od 15 A do 25 A CMC 0,22 % 45 Hz do 100 Hz od 15 A do 25 A CMC 0,12 % 100 Hz do 1 kHz od 15 A do 25 A CMC 0,51 % 30 Hz do 45 Hz od 25 A do 30 A CMC 0,21 % 45 Hz do 100 Hz od 25 A do 30 A CMC 0,11 % 100 Hz do 1 kHz od 25 A do 30 A CMC 0,49 % 50 Hz od 2,2 A do 3 A CMC 0,12 % 50 Hz od 3 A do 4 A CMC 0,095 % 50 Hz od 4 A do 5 A CMC 0,084 % 50 Hz od 5 A do 6 A CMC 0,077 % 50 Hz od 6 A do 7 A CMC 0,073 % 50 Hz od 7 A do 8 A CMC 0,070 % 50 Hz od 8 A do 10 A CMC 0,067 % 50 Hz od 10 A do 11 A CMC 0,064 % 50 Hz od 11 A do 15 A CMC 0,10 % 50 Hz od 15 A do 20 A CMC 0,081 % 50 Hz od 20 A do 90 A CMC 0,090 % Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 10 Hz až 20 Hz 10 µA až 20 µA CMC 40 nA 20 Hz až 40 Hz 10 µA až 20 µA CMC 28 nA 40 Hz až 1 kHz 10 µA až 20 µA CMC 18 nA 1 kHz až 5 kHz 10 µA až 20 µA CMC 47 nA 5 kHz až 10 kHz 10 µA až 20 µA CMC 97 nA 10 Hz až 20 Hz 20 µA až 30 µA CMC 0,20 % 20 Hz až 40 Hz 20 µA až 30 µA CMC 0,14 % 40 Hz až 1 kHz 20 µA až 30 µA CMC 0,095 % 1 kHz až 5 kHz 20 µA až 30 µA CMC 0,26 % 5 kHz až 10 kHz 20 µA až 30 µA CMC 0,57 % 10 Hz až 20 Hz 30 µA až 40 µA CMC 0,16 % 20 Hz až 40 Hz 30 µA až 40 µA CMC 0,11 % 40 Hz až 1 kHz 30 µA až 40 µA CMC 0,069 % 1 kHz až 5 kHz 30 µA až 40 µA CMC 0,20 % 5 kHz až 10 kHz 30 µA až 40 µA CMC 0,43 % 10 Hz až 20 Hz 40 µA až 50 µA CMC 0,14 % 20 Hz až 40 Hz 40 µA až 50 µA CMC 0,086 % 40 Hz až 1 kHz 40 µA až 50 µA CMC 0,055 % 1 kHz až 5 kHz 40 µA až 50 µA CMC 0,17 % 5 kHz až 10 kHz 40 µA až 50 µA CMC 0,37 % 10 Hz až 20 Hz 50 µA až 60 µA CMC 0,13 % 20 Hz až 40 Hz 50 µA až 60 µA CMC 0,076 % 40 Hz až 1 kHz 50 µA až 60 µA CMC 0,048 % 1 kHz až 5 kHz 50 µA až 60 µA CMC 0,15 % 5 kHz až 10 kHz 50 µA až 60 µA CMC 0,33 % 10 Hz až 20 Hz 60 µA až 80 µA CMC 0,12 % 20 Hz až 40 Hz 60 µA až 80 µA CMC 0,070 % 40 Hz až 1 kHz 60 µA až 80 µA CMC 0,042 % 1 kHz až 5 kHz 60 µA až 80 µA CMC 0,13 % 5 kHz až 10 kHz 60 µA až 80 µA CMC 0,30 % 10 Hz až 20 Hz 80 µA až 100 µA CMC 0,099 % 20 Hz až 40 Hz 80 µA až 100 µA CMC 0,061 % 40 Hz až 1 kHz 80 µA až 100 µA CMC 0,036 % 1 kHz až 5 kHz 80 µA až 100 µA CMC 0,12 % 5 kHz až 10 kHz 80 µA až 100 µA CMC 0,27 % 10 Hz až 20 Hz 100 µA až 130 µA CMC 0,096 % 20 Hz až 40 Hz 100 µA až 130 µA CMC 0,056 % 40 Hz až 1 kHz 100 µA až 130 µA CMC 0,032 % 1 kHz až 5 kHz 100 µA až 130 µA CMC 0,11 % 5 kHz až 10 kHz 100 µA až 130 µA CMC 0,25 % 10 Hz až 20 Hz 130 µA až 180 µA CMC 0,090 % 20 Hz až 40 Hz 130 µA až 180 µA CMC 0,052 % 40 Hz až 1 kHz 130 µA až 180 µA CMC 0,029 % 1 kHz až 5 kHz 130 µA až 180 µA CMC 0,092 % 5 kHz až 10 kHz 130 µA až 180 µA CMC 0,23 % 10 Hz až 20 Hz 180 µA až 220 µA CMC 0,085 % 20 Hz až 40 Hz 180 µA až 220 µA CMC 0,048 % 40 Hz až 1 kHz 180 µA až 220 µA CMC 0,025 % 1 kHz až 5 kHz 180 µA až 220 µA CMC 0,084 % 5 kHz až 10 kHz 180 µA až 220 µA CMC 0,21 % 10 Hz až 20 Hz 220 µA až 300 µA CMC 0,089 % 20 Hz až 40 Hz 220 µA až 300 µA CMC 0,052 % 40 Hz až 1 kHz 220 µA až 300 µA CMC 0,032 % 1 kHz až 5 kHz 220 µA až 300 µA CMC 0,25 % 5 kHz až 10 kHz 220 µA až 300 µA CMC 0,53 % 10 Hz až 20 Hz 300 µA až 400 µA CMC 0,084 % 20 Hz až 40 Hz 300 µA až 400 µA CMC 0,048 % 40 Hz až 1 kHz 300 µA až 400 µA CMC 0,028 % 1 kHz až 5 kHz 300 µA až 400 µA CMC 0,20 % 5 kHz až 10 kHz 300 µA až 400 µA CMC 0,43 % 10 Hz až 20 Hz 400 µA až 500 µA CMC 0,081 % 20 Hz až 40 Hz 400 µA až 500 µA CMC 0,045 % 40 Hz až 1 kHz 400 µA až 500 µA CMC 0,025 % 1 kHz až 5 kHz 400 µA až 500 µA CMC 0,17 % 5 kHz až 10 kHz 400 µA až 500 µA CMC 0,37 % 10 Hz až 20 Hz 500 µA až 600 µA CMC 0,079 % 20 Hz až 40 Hz 500 µA až 600 µA CMC 0,044 % 40 Hz až 1 kHz 500 µA až 600 µA CMC 0,023 % 1 kHz až 5 kHz 500 µA až 600 µA CMC 0,15 % 5 kHz až 10 kHz 500 µA až 600 µA CMC 0,33 % 10 Hz až 20 Hz 600 µA až 800 µA CMC 0,078 % 20 Hz až 40 Hz 600 µA až 800 µA CMC 0,043 % 40 Hz až 1 kHz 600 µA až 800 µA CMC 0,022 % 1 kHz až 5 kHz 600 µA až 800 µA CMC 0,13 % 5 kHz až 10 kHz 600 µA až 800 µA CMC 0,30 % 10 Hz až 20 Hz 800 µA až 1 mA CMC 0,076 % 20 Hz až 40 Hz 800 µA až 1 mA CMC 0,041 % 40 Hz až 1 kHz 800 µA až 1 mA CMC 0,021 % 1 kHz až 5 kHz 800 µA až 1 mA CMC 0,12 % 5 kHz až 10 kHz 800 µA až 1 mA CMC 0,27 % 10 Hz až 20 Hz 1 mA až 1,3 mA CMC 0,075 % 20 Hz až 40 Hz 1 mA až 1,3 mA CMC 0,040 % 40 Hz až 1 kHz 1 mA až 1,3 mA CMC 0,020 % 1 kHz až 5 kHz 1 mA až 1,3 mA CMC 0,11 % 5 kHz až 10 kHz 1 mA až 1,3 mA CMC 0,25 % 10 Hz až 20 Hz 1,3 mA až 1,8 mA CMC 0,074 % 20 Hz až 40 Hz 1,3 mA až 1,8 mA CMC 0,039 % 40 Hz až 1 kHz 1,3 mA až 1,8 mA CMC 0,019 % 1 kHz až 5 kHz 1,3 mA až 1,8 mA CMC 0,092 % 5 kHz až 10 kHz 1,3 mA až 1,8 mA CMC 0,23 % 10 Hz až 20 Hz 1,8 mA až 2,2 mA CMC 0,073 % 20 Hz až 40 Hz 1,8 mA až 2,2 mA CMC 0,074 % 40 Hz až 1 kHz 1,8 mA až 2,2 mA CMC 0,019 % 1 kHz až 5 kHz 1,8 mA až 2,2 mA CMC 0,084 % 5 kHz až 10 kHz 1,8 mA až 2,2 mA CMC 0,21 % 10 Hz až 20 Hz 2,2 mA až 3 mA CMC 0,089 % 20 Hz až 40 Hz 2,2 mA až 3 mA CMC 0,052 % 40 Hz až 1 kHz 2,2 mA až 3 mA CMC 0,032 % 1 kHz až 5 kHz 2,2 mA až 3 mA CMC 0,25 % 5 kHz až 10 kHz 2,2 mA až 3 mA CMC 0,53 % 10 Hz až 20 Hz 3 mA až 4 mA CMC 0,084 % 20 Hz až 40 Hz 3 mA až 4 mA CMC 0,048 % 40 Hz až 1 kHz 3 mA až 4 mA CMC 0,028 % 1 kHz až 5 kHz 3 mA až 4 mA CMC 0,20 % 5 kHz až 10 kHz 3 mA až 4 mA CMC 0,43 % 10 Hz až 20 Hz 4 mA až 5 mA CMC 0,081 % 20 Hz až 40 Hz 4 mA až 5 mA CMC 0,045 % 40 Hz až 1 kHz 4 mA až 5 mA CMC 0,025 % 1 kHz až 5 kHz 4 mA až 5 mA CMC 0,17 % 5 kHz až 10 kHz 4 mA až 5 mA CMC 0,37 % 10 Hz až 20 Hz 5 mA až 6 mA CMC 0,079 % 20 Hz až 40 Hz 5 mA až 6 mA CMC 0,043 % 40 Hz až 1 kHz 5 mA až 6 mA CMC 0,023 % 1 kHz až 5 kHz 5 mA až 6 mA CMC 0,15 % 5 kHz až 10 kHz 5 mA až 6 mA CMC 0,33 % 10 Hz až 20 Hz 6 mA až 8 mA CMC 0,078 % 20 Hz až 40 Hz 6 mA až 8 mA CMC 0,042 % 40 Hz až 1 kHz 6 mA až 8 mA CMC 0,022 % 1 kHz až 5 kHz 6 mA až 8 mA CMC 0,13 % 5 kHz až 10 kHz 6 mA až 8 mA CMC 0,30 % 10 Hz až 20 Hz 8 mA až 10 mA CMC 0,076 % 20 Hz až 40 Hz 8 mA až 10 mA CMC 0,041 % 40 Hz až 1 kHz 8 mA až 10 mA CMC 0,021 % 1 kHz až 5 kHz 8 mA až 10 mA CMC 0,12 % 5 kHz až 10 kHz 8 mA až 10 mA CMC 0,27 % 10 Hz až 20 Hz 10 mA až 13 mA CMC 0,075 % 20 Hz až 40 Hz 10 mA až 13 mA CMC 0,040 % 40 Hz až 1 kHz 10 mA až 13 mA CMC 0,020 % 1 kHz až 5 kHz 10 mA až 13 mA CMC 0,11 % 5 kHz až 10 kHz 10 mA až 13 mA CMC 0,25 % 10 Hz až 20 Hz 13 mA až 18 mA CMC 0,074 % 20 Hz až 40 Hz 13 mA až 18 mA CMC 0,039 % 40 Hz až 1 kHz 13 mA až 18 mA CMC 0,019 % 1 kHz až 5 kHz 13 mA až 18 mA CMC 0,092 % 5 kHz až 10 kHz 13 mA až 18 mA CMC 0,23 % 10 Hz až 20 Hz 18 mA až 22 mA CMC 0,073 % 20 Hz až 40 Hz 18 mA až 22 mA CMC 0,039 % 40 Hz až 1 kHz 18 mA až 22 mA CMC 0,019 % 1 kHz až 5 kHz 18 mA až 22 mA CMC 0,084 % 5 kHz až 10 kHz 18 mA až 22 mA CMC 0,21 % 10 Hz až 20 Hz 22 mA až 30 mA CMC 0,089 % 20 Hz až 40 Hz 22 mA až 30 mA CMC 0,052 % 40 Hz až 1 kHz 22 mA až 30 mA CMC 0,032 % 1 kHz až 5 kHz 22 mA až 30 mA CMC 0,25 % 5 kHz až 10 kHz 22 mA až 30 mA CMC 0,53 % 10 Hz až 20 Hz 30 mA až 40 mA CMC 0,084 % 20 Hz až 40 Hz 30 mA až 40 mA CMC 0,048 % 40 Hz až 1 kHz 30 mA až 40 mA CMC 0,028 % 1 kHz až 5 kHz 30 mA až 40 mA CMC 0,20 % 5 kHz až 10 kHz 30 mA až 40 mA CMC 0,43 % 10 Hz až 20 Hz 40 mA až 50 mA CMC 0,081 % 20 Hz až 40 Hz 40 mA až 50 mA CMC 0,045 % 40 Hz až 1 kHz 40 mA až 50 mA CMC 0,025 % 1 kHz až 5 kHz 40 mA až 50 mA CMC 0,17 % 5 kHz až 10 kHz 40 mA až 50 mA CMC 0,37 % 10 Hz až 20 Hz 50 mA až 60 mA CMC 0,079 % 20 Hz až 40 Hz 50 mA až 60 mA CMC 0,043 % 40 Hz až 1 kHz 50 mA až 60 mA CMC 0,023 % 1 kHz až 5 kHz 50 mA až 60 mA CMC 0,15 % 5 kHz až 10 kHz 50 mA až 60 mA CMC 0,33 % 10 Hz až 20 Hz 60 mA až 80 mA CMC 0,078 % 20 Hz až 40 Hz 60 mA až 80 mA CMC 0,042 % 40 Hz až 1 kHz 60 mA až 80 mA CMC 0,022 % 1 kHz až 5 kHz 60 mA až 80 mA CMC 0,13 % 5 kHz až 10 kHz 60 mA až 80 mA CMC 0,30 % 10 Hz až 20 Hz 80 mA až 100 mA CMC 0,076 % 20 Hz až 40 Hz 80 mA až 100 mA CMC 0,041 % 40 Hz až 1 kHz 80 mA až 100 mA CMC 0,021 % 1 kHz až 5 kHz 80 mA až 100 mA CMC 0,12 % 5 kHz až 10 kHz 80 mA až 100 mA CMC 0,27 % 10 Hz až 20 Hz 100 mA až 130 mA CMC 0,075 % 20 Hz až 40 Hz 100 mA až 130 mA CMC 0,040 % 40 Hz až 1 kHz 100 mA až 130 mA CMC 0,020 % 1 kHz až 5 kHz 100 mA až 130 mA CMC 0,11 % 5 kHz až 10 kHz 100 mA až 130 mA CMC 0,25 % 10 Hz až 20 Hz 130 mA až 180 mA CMC 0,074 % 20 Hz až 40 Hz 130 mA až 180 mA CMC 0,039 % 40 Hz až 1 kHz 130 mA až 180 mA CMC 0,019 % 1 kHz až 5 kHz 130 mA až 180 mA CMC 0,092 % 5 kHz až 10 kHz 130 mA až 180 mA CMC 0,24 % 10 Hz až 20 Hz 180 mA až 220 mA CMC 0,073 % 20 Hz až 40 Hz 180 mA až 220 mA CMC 0,038 % 40 Hz až 1 kHz 180 mA až 220 mA CMC 0,019 % 1 kHz až 5 kHz 180 mA až 220 mA CMC 0,084 % 5 kHz až 10 kHz 180 mA až 220 mA CMC 0,21 % 20 Hz až 1 kHz 220 mA až 300 mA CMC 0,082 % 1 kHz až 5 kHz 220 mA až 300 mA CMC 0,12 % 5 kHz až 10 kHz 220 mA až 300 mA CMC 0,93 % 20 Hz až 1 kHz 300 mA až 400 mA CMC 0,078 % 1 kHz až 5 kHz 300 mA až 400 mA CMC 0,11 % 5 kHz až 10 kHz 300 mA až 400 mA CMC 0,91 % 20 Hz až 1 kHz 400 mA až 500 mA CMC 0,075 % 1 kHz až 5 kHz 400 mA až 500 mA CMC 0,098 % 5 kHz až 10 kHz 400 mA až 500 mA CMC 0,90 % 20 Hz až 1 kHz 500 mA až 600 mA CMC 0,074 % 1 kHz až 5 kHz 500 mA až 600 mA CMC 0,094 % 5 kHz až 10 kHz 500 mA až 600 mA CMC 0,89 % 20 Hz až 1 kHz 600 mA až 1 A CMC 0,072 % 1 kHz až 5 kHz 600 mA až 1 A CMC 0,092 % 5 kHz až 10 kHz 600 mA až 1 A CMC 0,89 % 20 Hz až 1 kHz 1 A až 2,2 A CMC 0,070 % 1 kHz až 5 kHz 1 A až 2,2 A CMC 0,086 % 5 kHz až 10 kHz 1 A až 2,2 A CMC 0,88 % 10 Hz až 1 kHz 2,2 A až 3 A CMC 0,16 % 1 kHz až 5 kHz 2,2 A až 3 A CMC 0,22 % 5 kHz až 10 kHz 2,2 A až 3 A CMC 0,60 % 10 Hz až 1 kHz 3 A až 5 A CMC 0,14 % 1 kHz až 5 kHz 3 A až 5 A CMC 0,20 % 5 kHz až 10 kHz 3 A až 5 A CMC 0,51 % 10 Hz až 1 kHz 5 A až 11 A CMC 0,13 % 1 kHz až 5 kHz 5 A až 11 A CMC 0,18 % 5 kHz až 10 kHz 5 A až 11 A CMC 0,42 % 30 Hz až 45 Hz 11 A až 15 A CMC 0,23 % 45 Hz až 100 Hz 11 A až 15 A CMC 0,12 % 100 Hz až 1 kHz 11 A až 15 A CMC 0,52 % 30 Hz až 45 Hz 15 A až 25 A CMC 0,22 % 45 Hz až 100 Hz 15 A až 25 A CMC 0,12 % 100 Hz až 1 kHz 15 A až 25 A CMC 0,51 % 30 Hz až 45 Hz 25 A až 30 A CMC 0,21 % 45 Hz až 100 Hz 25 A až 30 A CMC 0,11 % 100 Hz až 1 kHz 25 A až 30 A CMC 0,49 % 50 Hz 2,2 A až 3 A CMC 0,12 % 50 Hz 3 A až 4 A CMC 0,095 % 50 Hz 4 A až 5 A CMC 0,084 % 50 Hz 5 A až 6 A CMC 0,077 % 50 Hz 6 A až 7 A CMC 0,073 % 50 Hz 7 A až 8 A CMC 0,070 % 50 Hz 8 A až 10 A CMC 0,067 % 50 Hz 10 A až 11 A CMC 0,064 % 50 Hz 11 A až 15 A CMC 0,10 % 50 Hz 15 A až 20 A CMC 0,081 % 50 Hz 20 A až 90 A CMC 0,090 % TP4, TP21 Prad przemienny / Mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 10 Hz do 20 Hz od 10 µA do 20 µA CMC 40 nA 20 Hz do 40 Hz od 10 µA do 20 µA CMC 28 nA 40 Hz do 1 kHz od 10 µA do 20 µA CMC 18 nA 1 kHz do 5 kHz od 10 µA do 20 µA CMC 47 nA 5 kHz do 10 kHz od 10 µA do 20 µA CMC 97 nA 10 Hz do 20 Hz od 20 µA do 30 µA CMC 0,20 % 20 Hz do 40 Hz od 20 µA do 30 µA CMC 0,14 % 40 Hz do 1 kHz od 20 µA do 30 µA CMC 0,095 % 1 kHz do 5 kHz od 20 µA do 30 µA CMC 0,26 % 5 kHz do 10 kHz od 20 µA do 30 µA CMC 0,57 % 10 Hz do 20 Hz od 30 µA do 40 µA CMC 0,16 % 20 Hz do 40 Hz od 30 µA do 40 µA CMC 0,11 % 40 Hz do 1 kHz od 30 µA do 40 µA CMC 0,069 % 1 kHz do 5 kHz od 30 µA do 40 µA CMC 0,20 % 5 kHz do 10 kHz od 30 µA do 40 µA CMC 0,43 % 10 Hz do 20 Hz od 40 µA do 50 µA CMC 0,14 % 20 Hz do 40 Hz od 40 µA do 50 µA CMC 0,086 % 40 Hz do 1 kHz od 40 µA do 50 µA CMC 0,055 % 1 kHz do 5 kHz od 40 µA do 50 µA CMC 0,17 % 5 kHz do 10 kHz od 40 µA do 50 µA CMC 0,37 % 10 Hz do 20 Hz od 50 µA do 60 µA CMC 0,13 % 20 Hz do 40 Hz od 50 µA do 60 µA CMC 0,076 % 40 Hz do 1 kHz od 50 µA do 60 µA CMC 0,048 % 1 kHz do 5 kHz od 50 µA do 60 µA CMC 0,15 % 5 kHz do 10 kHz od 50 µA do 60 µA CMC 0,33 % 10 Hz do 20 Hz od 60 µA do 80 µA CMC 0,12 % 20 Hz do 40 Hz od 60 µA do 80 µA CMC 0,070 % 40 Hz do 1 kHz od 60 µA do 80 µA CMC 0,042 % 1 kHz do 5 kHz od 60 µA do 80 µA CMC 0,13 % 5 kHz do 10 kHz od 60 µA do 80 µA CMC 0,30 % 10 Hz do 20 Hz od 80 µA do 100 µA CMC 0,099 % 20 Hz do 40 Hz od 80 µA do 100 µA CMC 0,061 % 40 Hz do 1 kHz od 80 µA do 100 µA CMC 0,036 % 1 kHz do 5 kHz od 80 µA do 100 µA CMC 0,12 % 5 kHz do 10 kHz od 80 µA do 100 µA CMC 0,27 % 10 Hz do 20 Hz od 100 µA do 130 µA CMC 0,096 % 20 Hz do 40 Hz od 100 µA do 130 µA CMC 0,056 % 40 Hz do 1 kHz od 100 µA do 130 µA CMC 0,032 % 1 kHz do 5 kHz od 100 µA do 130 µA CMC 0,11 % 5 kHz do 10 kHz od 100 µA do 130 µA CMC 0,25 % 10 Hz do 20 Hz od 130 µA do 180 µA CMC 0,090 % 20 Hz do 40 Hz od 130 µA do 180 µA CMC 0,052 % 40 Hz do 1 kHz od 130 µA do 180 µA CMC 0,029 % 1 kHz do 5 kHz od 130 µA do 180 µA CMC 0,092 % 5 kHz do 10 kHz od 130 µA do 180 µA CMC 0,23 % 10 Hz do 20 Hz od 180 µA do 220 µA CMC 0,085 % 20 Hz do 40 Hz od 180 µA do 220 µA CMC 0,048 % 40 Hz do 1 kHz od 180 µA do 220 µA CMC 0,025 % 1 kHz do 5 kHz od 180 µA do 220 µA CMC 0,084 % 5 kHz do 10 kHz od 180 µA do 220 µA CMC 0,21 % 10 Hz do 20 Hz od 220 µA do 300 µA CMC 0,089 % 20 Hz do 40 Hz od 220 µA do 300 µA CMC 0,052 % 40 Hz do 1 kHz od 220 µA do 300 µA CMC 0,032 % 1 kHz do 5 kHz od 220 µA do 300 µA CMC 0,25 % 5 kHz do 10 kHz od 220 µA do 300 µA CMC 0,53 % 10 Hz do 20 Hz od 300 µA do 400 µA CMC 0,084 % 20 Hz do 40 Hz od 300 µA do 400 µA CMC 0,048 % 40 Hz do 1 kHz od 300 µA do 400 µA CMC 0,028 % 1 kHz do 5 kHz od 300 µA do 400 µA CMC 0,20 % 5 kHz do 10 kHz od 300 µA do 400 µA CMC 0,43 % 10 Hz do 20 Hz od 400 µA do 500 µA CMC 0,081 % 20 Hz do 40 Hz od 400 µA do 500 µA CMC 0,045 % 40 Hz do 1 kHz od 400 µA do 500 µA CMC 0,025 % 1 kHz do 5 kHz od 400 µA do 500 µA CMC 0,17 % 5 kHz do 10 kHz od 400 µA do 500 µA CMC 0,37 % 10 Hz do 20 Hz od 500 µA do 600 µA CMC 0,079 % 20 Hz do 40 Hz od 500 µA do 600 µA CMC 0,044 % 40 Hz do 1 kHz od 500 µA do 600 µA CMC 0,023 % 1 kHz do 5 kHz od 500 µA do 600 µA CMC 0,15 % 5 kHz do 10 kHz od 500 µA do 600 µA CMC 0,33 % 10 Hz do 20 Hz od 600 µA do 800 µA CMC 0,078 % 20 Hz do 40 Hz od 600 µA do 800 µA CMC 0,043 % 40 Hz do 1 kHz od 600 µA do 800 µA CMC 0,022 % 1 kHz do 5 kHz od 600 µA do 800 µA CMC 0,13 % 5 kHz do 10 kHz od 600 µA do 800 µA CMC 0,30 % 10 Hz do 20 Hz od 800 µA do 1 mA CMC 0,076 % 20 Hz do 40 Hz od 800 µA do 1 mA CMC 0,041 % 40 Hz do 1 kHz od 800 µA do 1 mA CMC 0,021 % 1 kHz do 5 kHz od 800 µA do 1 mA CMC 0,12 % 5 kHz do 10 kHz od 800 µA do 1 mA CMC 0,27 % 10 Hz do 20 Hz od 1 mA do 1,3 mA CMC 0,075 % 20 Hz do 40 Hz od 1 mA do 1,3 mA CMC 0,040 % 40 Hz do 1 kHz od 1 mA do 1,3 mA CMC 0,020 % 1 kHz do 5 kHz od 1 mA do 1,3 mA CMC 0,11 % 5 kHz do 10 kHz od 1 mA do 1,3 mA CMC 0,25 % 10 Hz do 20 Hz od 1,3 mA do 1,8 mA CMC 0,074 % 20 Hz do 40 Hz od 1,3 mA do 1,8 mA CMC 0,039 % 40 Hz do 1 kHz od 1,3 mA do 1,8 mA CMC 0,019 % 1 kHz do 5 kHz od 1,3 mA do 1,8 mA CMC 0,092 % 5 kHz do 10 kHz od 1,3 mA do 1,8 mA CMC 0,23 % 10 Hz do 20 Hz od 1,8 mA do 2,2 mA CMC 0,073 % 20 Hz do 40 Hz od 1,8 mA do 2,2 mA CMC 0,074 % 40 Hz do 1 kHz od 1,8 mA do 2,2 mA CMC 0,019 % 1 kHz do 5 kHz od 1,8 mA do 2,2 mA CMC 0,084 % 5 kHz do 10 kHz od 1,8 mA do 2,2 mA CMC 0,21 % 10 Hz do 20 Hz od 2,2 mA do 3 mA CMC 0,089 % 20 Hz do 40 Hz od 2,2 mA do 3 mA CMC 0,052 % 40 Hz do 1 kHz od 2,2 mA do 3 mA CMC 0,032 % 1 kHz do 5 kHz od 2,2 mA do 3 mA CMC 0,25 % 5 kHz do 10 kHz od 2,2 mA do 3 mA CMC 0,53 % 10 Hz do 20 Hz od 3 mA do 4 mA CMC 0,084 % 20 Hz do 40 Hz od 3 mA do 4 mA CMC 0,048 % 40 Hz do 1 kHz od 3 mA do 4 mA CMC 0,028 % 1 kHz do 5 kHz od 3 mA do 4 mA CMC 0,20 % 5 kHz do 10 kHz od 3 mA do 4 mA CMC 0,43 % 10 Hz do 20 Hz od 4 mA do 5 mA CMC 0,081 % 20 Hz do 40 Hz od 4 mA do 5 mA CMC 0,045 % 40 Hz do 1 kHz od 4 mA do 5 mA CMC 0,025 % 1 kHz do 5 kHz od 4 mA do 5 mA CMC 0,17 % 5 kHz do 10 kHz od 4 mA do 5 mA CMC 0,37 % 10 Hz do 20 Hz od 5 mA do 6 mA CMC 0,079 % 20 Hz do 40 Hz od 5 mA do 6 mA CMC 0,043 % 40 Hz do 1 kHz od 5 mA do 6 mA CMC 0,023 % 1 kHz do 5 kHz od 5 mA do 6 mA CMC 0,15 % 5 kHz do 10 kHz od 5 mA do 6 mA CMC 0,33 % 10 Hz do 20 Hz od 6 mA do 8 mA CMC 0,078 % 20 Hz do 40 Hz od 6 mA do 8 mA CMC 0,042 % 40 Hz do 1 kHz od 6 mA do 8 mA CMC 0,022 % 1 kHz do 5 kHz od 6 mA do 8 mA CMC 0,13 % 5 kHz do 10 kHz od 6 mA do 8 mA CMC 0,30 % 10 Hz do 20 Hz od 8 mA do 10 mA CMC 0,076 % 20 Hz do 40 Hz od 8 mA do 10 mA CMC 0,041 % 40 Hz do 1 kHz od 8 mA do 10 mA CMC 0,021 % 1 kHz do 5 kHz od 8 mA do 10 mA CMC 0,12 % 5 kHz do 10 kHz od 8 mA do 10 mA CMC 0,27 % 10 Hz do 20 Hz od 10 mA do 13 mA CMC 0,075 % 20 Hz do 40 Hz od 10 mA do 13 mA CMC 0,040 % 40 Hz do 1 kHz od 10 mA do 13 mA CMC 0,020 % 1 kHz do 5 kHz od 10 mA do 13 mA CMC 0,11 % 5 kHz do 10 kHz od 10 mA do 13 mA CMC 0,25 % 10 Hz do 20 Hz od 13 mA do 18 mA CMC 0,074 % 20 Hz do 40 Hz od 13 mA do 18 mA CMC 0,039 % 40 Hz do 1 kHz od 13 mA do 18 mA CMC 0,019 % 1 kHz do 5 kHz od 13 mA do 18 mA CMC 0,092 % 5 kHz do 10 kHz od 13 mA do 18 mA CMC 0,23 % 10 Hz do 20 Hz od 18 mA do 22 mA CMC 0,073 % 20 Hz do 40 Hz od 18 mA do 22 mA CMC 0,039 % 40 Hz do 1 kHz od 18 mA do 22 mA CMC 0,019 % 1 kHz do 5 kHz od 18 mA do 22 mA CMC 0,084 % 5 kHz do 10 kHz od 18 mA do 22 mA CMC 0,21 % 10 Hz do 20 Hz od 22 mA do 30 mA CMC 0,089 % 20 Hz do 40 Hz od 22 mA do 30 mA CMC 0,052 % 40 Hz do 1 kHz od 22 mA do 30 mA CMC 0,032 % 1 kHz do 5 kHz od 22 mA do 30 mA CMC 0,25 % 5 kHz do 10 kHz od 22 mA do 30 mA CMC 0,53 % 10 Hz do 20 Hz od 30 mA do 40 mA CMC 0,084 % 20 Hz do 40 Hz od 30 mA do 40 mA CMC 0,048 % 40 Hz do 1 kHz od 30 mA do 40 mA CMC 0,028 % 1 kHz do 5 kHz od 30 mA do 40 mA CMC 0,20 % 5 kHz do 10 kHz od 30 mA do 40 mA CMC 0,43 % 10 Hz do 20 Hz od 40 mA do 50 mA CMC 0,081 % 20 Hz do 40 Hz od 40 mA do 50 mA CMC 0,045 % 40 Hz do 1 kHz od 40 mA do 50 mA CMC 0,025 % 1 kHz do 5 kHz od 40 mA do 50 mA CMC 0,17 % 5 kHz do 10 kHz od 40 mA do 50 mA CMC 0,37 % 10 Hz do 20 Hz od 50 mA do 60 mA CMC 0,079 % 20 Hz do 40 Hz od 50 mA do 60 mA CMC 0,043 % 40 Hz do 1 kHz od 50 mA do 60 mA CMC 0,023 % 1 kHz do 5 kHz od 50 mA do 60 mA CMC 0,15 % 5 kHz do 10 kHz od 50 mA do 60 mA CMC 0,33 % 10 Hz do 20 Hz od 60 mA do 80 mA CMC 0,078 % 20 Hz do 40 Hz od 60 mA do 80 mA CMC 0,042 % 40 Hz do 1 kHz od 60 mA do 80 mA CMC 0,022 % 1 kHz do 5 kHz od 60 mA do 80 mA CMC 0,13 % 5 kHz do 10 kHz od 60 mA do 80 mA CMC 0,30 % 10 Hz do 20 Hz od 80 mA do 100 mA CMC 0,076 % 20 Hz do 40 Hz od 80 mA do 100 mA CMC 0,041 % 40 Hz do 1 kHz od 80 mA do 100 mA CMC 0,021 % 1 kHz do 5 kHz od 80 mA do 100 mA CMC 0,12 % 5 kHz do 10 kHz od 80 mA do 100 mA CMC 0,27 % 10 Hz do 20 Hz od 100 mA do 130 mA CMC 0,075 % 20 Hz do 40 Hz od 100 mA do 130 mA CMC 0,040 % 40 Hz do 1 kHz od 100 mA do 130 mA CMC 0,020 % 1 kHz do 5 kHz od 100 mA do 130 mA CMC 0,11 % 5 kHz do 10 kHz od 100 mA do 130 mA CMC 0,25 % 10 Hz do 20 Hz od 130 mA do 180 mA CMC 0,074 % 20 Hz do 40 Hz od 130 mA do 180 mA CMC 0,039 % 40 Hz do 1 kHz od 130 mA do 180 mA CMC 0,019 % 1 kHz do 5 kHz od 130 mA do 180 mA CMC 0,092 % 5 kHz do 10 kHz od 130 mA do 180 mA CMC 0,24 % 10 Hz do 20 Hz od 180 mA do 220 mA CMC 0,073 % 20 Hz do 40 Hz od 180 mA do 220 mA CMC 0,038 % 40 Hz do 1 kHz od 180 mA do 220 mA CMC 0,019 % 1 kHz do 5 kHz od 180 mA do 220 mA CMC 0,084 % 5 kHz do 10 kHz od 180 mA do 220 mA CMC 0,21 % 20 Hz do 1 kHz od 220 mA do 300 mA CMC 0,082 % 1 kHz do 5 kHz od 220 mA do 300 mA CMC 0,12 % 5 kHz do 10 kHz od 220 mA do 300 mA CMC 0,93 % 20 Hz do 1 kHz od 300 mA do 400 mA CMC 0,078 % 1 kHz do 5 kHz od 300 mA do 400 mA CMC 0,11 % 5 kHz do 10 kHz od 300 mA do 400 mA CMC 0,91 % 20 Hz do 1 kHz od 400 mA do 500 mA CMC 0,075 % 1 kHz do 5 kHz od 400 mA do 500 mA CMC 0,098 % 5 kHz do 10 kHz od 400 mA do 500 mA CMC 0,90 % 20 Hz do 1 kHz od 500 mA do 600 mA CMC 0,074 % 1 kHz do 5 kHz od 500 mA do 600 mA CMC 0,094 % 5 kHz do 10 kHz od 500 mA do 600 mA CMC 0,89 % 20 Hz do 1 kHz od 600 mA do 1 A CMC 0,072 % 1 kHz do 5 kHz od 600 mA do 1 A CMC 0,092 % 5 kHz do 10 kHz od 600 mA do 1 A CMC 0,89 % 20 Hz do 1 kHz od 1 A do 2,2 A CMC 0,070 % 1 kHz do 5 kHz od 1 A do 2,2 A CMC 0,086 % 5 kHz do 10 kHz od 1 A do 2,2 A CMC 0,88 % 10 Hz do 1 kHz od 2,2 A do 3 A CMC 0,16 % 1 kHz do 5 kHz od 2,2 A do 3 A CMC 0,22 % 5 kHz do 10 kHz od 2,2 A do 3 A CMC 0,60 % 10 Hz do 1 kHz od 3 A do 5 A CMC 0,14 % 1 kHz do 5 kHz od 3 A do 5 A CMC 0,20 % 5 kHz do 10 kHz od 3 A do 5 A CMC 0,51 % 10 Hz do 1 kHz od 5 A do 11 A CMC 0,13 % 1 kHz do 5 kHz od 5 A do 11 A CMC 0,18 % 5 kHz do 10 kHz od 5 A do 11 A CMC 0,42 % 30 Hz do 45 Hz od 11 A do 15 A CMC 0,23 % 45 Hz do 100 Hz od 11 A do 15 A CMC 0,12 % 100 Hz do 1 kHz od 11 A do 15 A CMC 0,52 % 30 Hz do 45 Hz od 15 A do 25 A CMC 0,22 % 45 Hz do 100 Hz od 15 A do 25 A CMC 0,12 % 100 Hz do 1 kHz od 15 A do 25 A CMC 0,51 % 30 Hz do 45 Hz od 25 A do 30 A CMC 0,21 % 45 Hz do 100 Hz od 25 A do 30 A CMC 0,11 % 100 Hz do 1 kHz od 25 A do 30 A CMC 0,49 % 50 Hz od 2,2 A do 3 A CMC 0,12 % 50 Hz od 3 A do 4 A CMC 0,095 % 50 Hz od 4 A do 5 A CMC 0,084 % 50 Hz od 5 A do 6 A CMC 0,077 % 50 Hz od 6 A do 7 A CMC 0,073 % 50 Hz od 7 A do 8 A CMC 0,070 % 50 Hz od 8 A do 10 A CMC 0,067 % 50 Hz od 10 A do 11 A CMC 0,064 % 50 Hz od 11 A do 15 A CMC 0,10 % 50 Hz od 15 A do 20 A CMC 0,081 % 50 Hz od 20 A do 90 A CMC 0,090 % Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Prime generovani kalibratorem 10 Hz az 20 Hz 10 µA az 20 µA CMC 40 nA 20 Hz az 40 Hz 10 µA az 20 µA CMC 28 nA 40 Hz az 1 kHz 10 µA az 20 µA CMC 18 nA 1 kHz az 5 kHz 10 µA az 20 µA CMC 47 nA 5 kHz az 10 kHz 10 µA az 20 µA CMC 97 nA 10 Hz az 20 Hz 20 µA az 30 µA CMC 0,20 % 20 Hz az 40 Hz 20 µA az 30 µA CMC 0,14 % 40 Hz az 1 kHz 20 µA az 30 µA CMC 0,095 % 1 kHz az 5 kHz 20 µA az 30 µA CMC 0,26 % 5 kHz az 10 kHz 20 µA az 30 µA CMC 0,57 % 10 Hz az 20 Hz 30 µA az 40 µA CMC 0,16 % 20 Hz az 40 Hz 30 µA az 40 µA CMC 0,11 % 40 Hz az 1 kHz 30 µA az 40 µA CMC 0,069 % 1 kHz az 5 kHz 30 µA az 40 µA CMC 0,20 % 5 kHz az 10 kHz 30 µA az 40 µA CMC 0,43 % 10 Hz az 20 Hz 40 µA az 50 µA CMC 0,14 % 20 Hz az 40 Hz 40 µA az 50 µA CMC 0,086 % 40 Hz az 1 kHz 40 µA az 50 µA CMC 0,055 % 1 kHz az 5 kHz 40 µA az 50 µA CMC 0,17 % 5 kHz az 10 kHz 40 µA az 50 µA CMC 0,37 % 10 Hz az 20 Hz 50 µA az 60 µA CMC 0,13 % 20 Hz az 40 Hz 50 µA az 60 µA CMC 0,076 % 40 Hz az 1 kHz 50 µA az 60 µA CMC 0,048 % 1 kHz az 5 kHz 50 µA az 60 µA CMC 0,15 % 5 kHz az 10 kHz 50 µA az 60 µA CMC 0,33 % 10 Hz az 20 Hz 60 µA az 80 µA CMC 0,12 % 20 Hz az 40 Hz 60 µA az 80 µA CMC 0,070 % 40 Hz az 1 kHz 60 µA az 80 µA CMC 0,042 % 1 kHz az 5 kHz 60 µA az 80 µA CMC 0,13 % 5 kHz az 10 kHz 60 µA az 80 µA CMC 0,30 % 10 Hz az 20 Hz 80 µA az 100 µA CMC 0,099 % 20 Hz az 40 Hz 80 µA az 100 µA CMC 0,061 % 40 Hz az 1 kHz 80 µA az 100 µA CMC 0,036 % 1 kHz az 5 kHz 80 µA az 100 µA CMC 0,12 % 5 kHz az 10 kHz 80 µA az 100 µA CMC 0,27 % 10 Hz az 20 Hz 100 µA az 130 µA CMC 0,096 % 20 Hz az 40 Hz 100 µA az 130 µA CMC 0,056 % 40 Hz az 1 kHz 100 µA az 130 µA CMC 0,032 % 1 kHz az 5 kHz 100 µA az 130 µA CMC 0,11 % 5 kHz az 10 kHz 100 µA az 130 µA CMC 0,25 % 10 Hz az 20 Hz 130 µA az 180 µA CMC 0,090 % 20 Hz az 40 Hz 130 µA az 180 µA CMC 0,052 % 40 Hz az 1 kHz 130 µA az 180 µA CMC 0,029 % 1 kHz az 5 kHz 130 µA az 180 µA CMC 0,092 % 5 kHz az 10 kHz 130 µA az 180 µA CMC 0,23 % 10 Hz az 20 Hz 180 µA az 220 µA CMC 0,085 % 20 Hz az 40 Hz 180 µA az 220 µA CMC 0,048 % 40 Hz az 1 kHz 180 µA az 220 µA CMC 0,025 % 1 kHz az 5 kHz 180 µA az 220 µA CMC 0,084 % 5 kHz az 10 kHz 180 µA az 220 µA CMC 0,21 % 10 Hz az 20 Hz 220 µA az 300 µA CMC 0,089 % 20 Hz az 40 Hz 220 µA az 300 µA CMC 0,052 % 40 Hz az 1 kHz 220 µA az 300 µA CMC 0,032 % 1 kHz az 5 kHz 220 µA az 300 µA CMC 0,25 % 5 kHz az 10 kHz 220 µA az 300 µA CMC 0,53 % 10 Hz az 20 Hz 300 µA az 400 µA CMC 0,084 % 20 Hz az 40 Hz 300 µA az 400 µA CMC 0,048 % 40 Hz az 1 kHz 300 µA az 400 µA CMC 0,028 % 1 kHz az 5 kHz 300 µA az 400 µA CMC 0,20 % 5 kHz az 10 kHz 300 µA az 400 µA CMC 0,43 % 10 Hz az 20 Hz 400 µA az 500 µA CMC 0,081 % 20 Hz az 40 Hz 400 µA az 500 µA CMC 0,045 % 40 Hz az 1 kHz 400 µA az 500 µA CMC 0,025 % 1 kHz az 5 kHz 400 µA az 500 µA CMC 0,17 % 5 kHz az 10 kHz 400 µA az 500 µA CMC 0,37 % 10 Hz az 20 Hz 500 µA az 600 µA CMC 0,079 % 20 Hz az 40 Hz 500 µA az 600 µA CMC 0,044 % 40 Hz az 1 kHz 500 µA az 600 µA CMC 0,023 % 1 kHz az 5 kHz 500 µA az 600 µA CMC 0,15 % 5 kHz az 10 kHz 500 µA az 600 µA CMC 0,33 % 10 Hz az 20 Hz 600 µA az 800 µA CMC 0,078 % 20 Hz az 40 Hz 600 µA az 800 µA CMC 0,043 % 40 Hz az 1 kHz 600 µA az 800 µA CMC 0,022 % 1 kHz az 5 kHz 600 µA az 800 µA CMC 0,13 % 5 kHz az 10 kHz 600 µA az 800 µA CMC 0,30 % 10 Hz az 20 Hz 800 µA az 1 mA CMC 0,076 % 20 Hz az 40 Hz 800 µA az 1 mA CMC 0,041 % 40 Hz az 1 kHz 800 µA az 1 mA CMC 0,021 % 1 kHz az 5 kHz 800 µA az 1 mA CMC 0,12 % 5 kHz az 10 kHz 800 µA az 1 mA CMC 0,27 % 10 Hz az 20 Hz 1 mA az 1,3 mA CMC 0,075 % 20 Hz az 40 Hz 1 mA az 1,3 mA CMC 0,040 % 40 Hz az 1 kHz 1 mA az 1,3 mA CMC 0,020 % 1 kHz az 5 kHz 1 mA az 1,3 mA CMC 0,11 % 5 kHz az 10 kHz 1 mA az 1,3 mA CMC 0,25 % 10 Hz az 20 Hz 1,3 mA az 1,8 mA CMC 0,074 % 20 Hz az 40 Hz 1,3 mA az 1,8 mA CMC 0,039 % 40 Hz az 1 kHz 1,3 mA az 1,8 mA CMC 0,019 % 1 kHz az 5 kHz 1,3 mA az 1,8 mA CMC 0,092 % 5 kHz az 10 kHz 1,3 mA az 1,8 mA CMC 0,23 % 10 Hz az 20 Hz 1,8 mA az 2,2 mA CMC 0,073 % 20 Hz az 40 Hz 1,8 mA az 2,2 mA CMC 0,074 % 40 Hz az 1 kHz 1,8 mA az 2,2 mA CMC 0,019 % 1 kHz az 5 kHz 1,8 mA az 2,2 mA CMC 0,084 % 5 kHz az 10 kHz 1,8 mA az 2,2 mA CMC 0,21 % 10 Hz az 20 Hz 2,2 mA az 3 mA CMC 0,089 % 20 Hz az 40 Hz 2,2 mA az 3 mA CMC 0,052 % 40 Hz az 1 kHz 2,2 mA az 3 mA CMC 0,032 % 1 kHz az 5 kHz 2,2 mA az 3 mA CMC 0,25 % 5 kHz az 10 kHz 2,2 mA az 3 mA CMC 0,53 % 10 Hz az 20 Hz 3 mA az 4 mA CMC 0,084 % 20 Hz az 40 Hz 3 mA az 4 mA CMC 0,048 % 40 Hz az 1 kHz 3 mA az 4 mA CMC 0,028 % 1 kHz az 5 kHz 3 mA az 4 mA CMC 0,20 % 5 kHz az 10 kHz 3 mA az 4 mA CMC 0,43 % 10 Hz az 20 Hz 4 mA az 5 mA CMC 0,081 % 20 Hz az 40 Hz 4 mA az 5 mA CMC 0,045 % 40 Hz az 1 kHz 4 mA az 5 mA CMC 0,025 % 1 kHz az 5 kHz 4 mA az 5 mA CMC 0,17 % 5 kHz az 10 kHz 4 mA az 5 mA CMC 0,37 % 10 Hz az 20 Hz 5 mA az 6 mA CMC 0,079 % 20 Hz az 40 Hz 5 mA az 6 mA CMC 0,043 % 40 Hz az 1 kHz 5 mA az 6 mA CMC 0,023 % 1 kHz az 5 kHz 5 mA az 6 mA CMC 0,15 % 5 kHz az 10 kHz 5 mA az 6 mA CMC 0,33 % 10 Hz az 20 Hz 6 mA az 8 mA CMC 0,078 % 20 Hz az 40 Hz 6 mA az 8 mA CMC 0,042 % 40 Hz az 1 kHz 6 mA az 8 mA CMC 0,022 % 1 kHz az 5 kHz 6 mA az 8 mA CMC 0,13 % 5 kHz az 10 kHz 6 mA az 8 mA CMC 0,30 % 10 Hz az 20 Hz 8 mA az 10 mA CMC 0,076 % 20 Hz az 40 Hz 8 mA az 10 mA CMC 0,041 % 40 Hz az 1 kHz 8 mA az 10 mA CMC 0,021 % 1 kHz az 5 kHz 8 mA az 10 mA CMC 0,12 % 5 kHz az 10 kHz 8 mA az 10 mA CMC 0,27 % 10 Hz az 20 Hz 10 mA az 13 mA CMC 0,075 % 20 Hz az 40 Hz 10 mA az 13 mA CMC 0,040 % 40 Hz az 1 kHz 10 mA az 13 mA CMC 0,020 % 1 kHz az 5 kHz 10 mA az 13 mA CMC 0,11 % 5 kHz az 10 kHz 10 mA az 13 mA CMC 0,25 % 10 Hz az 20 Hz 13 mA az 18 mA CMC 0,074 % 20 Hz az 40 Hz 13 mA az 18 mA CMC 0,039 % 40 Hz az 1 kHz 13 mA az 18 mA CMC 0,019 % 1 kHz az 5 kHz 13 mA az 18 mA CMC 0,092 % 5 kHz az 10 kHz 13 mA az 18 mA CMC 0,23 % 10 Hz az 20 Hz 18 mA az 22 mA CMC 0,073 % 20 Hz az 40 Hz 18 mA az 22 mA CMC 0,039 % 40 Hz az 1 kHz 18 mA az 22 mA CMC 0,019 % 1 kHz az 5 kHz 18 mA az 22 mA CMC 0,084 % 5 kHz az 10 kHz 18 mA az 22 mA CMC 0,21 % 10 Hz az 20 Hz 22 mA az 30 mA CMC 0,089 % 20 Hz az 40 Hz 22 mA az 30 mA CMC 0,052 % 40 Hz az 1 kHz 22 mA az 30 mA CMC 0,032 % 1 kHz az 5 kHz 22 mA az 30 mA CMC 0,25 % 5 kHz az 10 kHz 22 mA az 30 mA CMC 0,53 % 10 Hz az 20 Hz 30 mA az 40 mA CMC 0,084 % 20 Hz az 40 Hz 30 mA az 40 mA CMC 0,048 % 40 Hz az 1 kHz 30 mA az 40 mA CMC 0,028 % 1 kHz az 5 kHz 30 mA az 40 mA CMC 0,20 % 5 kHz az 10 kHz 30 mA az 40 mA CMC 0,43 % 10 Hz az 20 Hz 40 mA az 50 mA CMC 0,081 % 20 Hz az 40 Hz 40 mA az 50 mA CMC 0,045 % 40 Hz az 1 kHz 40 mA az 50 mA CMC 0,025 % 1 kHz az 5 kHz 40 mA az 50 mA CMC 0,17 % 5 kHz az 10 kHz 40 mA az 50 mA CMC 0,37 % 10 Hz az 20 Hz 50 mA az 60 mA CMC 0,079 % 20 Hz az 40 Hz 50 mA az 60 mA CMC 0,043 % 40 Hz az 1 kHz 50 mA az 60 mA CMC 0,023 % 1 kHz az 5 kHz 50 mA az 60 mA CMC 0,15 % 5 kHz az 10 kHz 50 mA az 60 mA CMC 0,33 % 10 Hz az 20 Hz 60 mA az 80 mA CMC 0,078 % 20 Hz az 40 Hz 60 mA az 80 mA CMC 0,042 % 40 Hz az 1 kHz 60 mA az 80 mA CMC 0,022 % 1 kHz az 5 kHz 60 mA az 80 mA CMC 0,13 % 5 kHz az 10 kHz 60 mA az 80 mA CMC 0,30 % 10 Hz az 20 Hz 80 mA az 100 mA CMC 0,076 % 20 Hz az 40 Hz 80 mA az 100 mA CMC 0,041 % 40 Hz az 1 kHz 80 mA az 100 mA CMC 0,021 % 1 kHz az 5 kHz 80 mA az 100 mA CMC 0,12 % 5 kHz az 10 kHz 80 mA az 100 mA CMC 0,27 % 10 Hz az 20 Hz 100 mA az 130 mA CMC 0,075 % 20 Hz az 40 Hz 100 mA az 130 mA CMC 0,040 % 40 Hz az 1 kHz 100 mA az 130 mA CMC 0,020 % 1 kHz az 5 kHz 100 mA az 130 mA CMC 0,11 % 5 kHz az 10 kHz 100 mA az 130 mA CMC 0,25 % 10 Hz az 20 Hz 130 mA az 180 mA CMC 0,074 % 20 Hz az 40 Hz 130 mA az 180 mA CMC 0,039 % 40 Hz az 1 kHz 130 mA az 180 mA CMC 0,019 % 1 kHz az 5 kHz 130 mA az 180 mA CMC 0,092 % 5 kHz az 10 kHz 130 mA az 180 mA CMC 0,24 % 10 Hz az 20 Hz 180 mA az 220 mA CMC 0,073 % 20 Hz az 40 Hz 180 mA az 220 mA CMC 0,038 % 40 Hz az 1 kHz 180 mA az 220 mA CMC 0,019 % 1 kHz az 5 kHz 180 mA az 220 mA CMC 0,084 % 5 kHz az 10 kHz 180 mA az 220 mA CMC 0,21 % 20 Hz az 1 kHz 220 mA az 300 mA CMC 0,082 % 1 kHz az 5 kHz 220 mA az 300 mA CMC 0,12 % 5 kHz az 10 kHz 220 mA az 300 mA CMC 0,93 % 20 Hz az 1 kHz 300 mA az 400 mA CMC 0,078 % 1 kHz az 5 kHz 300 mA az 400 mA CMC 0,11 % 5 kHz az 10 kHz 300 mA az 400 mA CMC 0,91 % 20 Hz az 1 kHz 400 mA az 500 mA CMC 0,075 % 1 kHz az 5 kHz 400 mA az 500 mA CMC 0,098 % 5 kHz az 10 kHz 400 mA az 500 mA CMC 0,90 % 20 Hz az 1 kHz 500 mA az 600 mA CMC 0,074 % 1 kHz az 5 kHz 500 mA az 600 mA CMC 0,094 % 5 kHz az 10 kHz 500 mA az 600 mA CMC 0,89 % 20 Hz az 1 kHz 600 mA az 1 A CMC 0,072 % 1 kHz az 5 kHz 600 mA az 1 A CMC 0,092 % 5 kHz az 10 kHz 600 mA az 1 A CMC 0,89 % 20 Hz az 1 kHz 1 A az 2,2 A CMC 0,070 % 1 kHz az 5 kHz 1 A az 2,2 A CMC 0,086 % 5 kHz az 10 kHz 1 A az 2,2 A CMC 0,88 % 10 Hz az 1 kHz 2,2 A az 3 A CMC 0,16 % 1 kHz az 5 kHz 2,2 A az 3 A CMC 0,22 % 5 kHz az 10 kHz 2,2 A az 3 A CMC 0,60 % 10 Hz az 1 kHz 3 A az 5 A CMC 0,14 % 1 kHz az 5 kHz 3 A az 5 A CMC 0,20 % 5 kHz az 10 kHz 3 A az 5 A CMC 0,51 % 10 Hz az 1 kHz 5 A az 11 A CMC 0,13 % 1 kHz az 5 kHz 5 A az 11 A CMC 0,18 % 5 kHz az 10 kHz 5 A az 11 A CMC 0,42 % 30 Hz az 45 Hz 11 A az 15 A CMC 0,23 % 45 Hz az 100 Hz 11 A az 15 A CMC 0,12 % 100 Hz az 1 kHz 11 A az 15 A CMC 0,52 % 30 Hz az 45 Hz 15 A az 25 A CMC 0,22 % 45 Hz az 100 Hz 15 A az 25 A CMC 0,12 % 100 Hz az 1 kHz 15 A az 25 A CMC 0,51 % 30 Hz az 45 Hz 25 A az 30 A CMC 0,21 % 45 Hz az 100 Hz 25 A az 30 A CMC 0,11 % 100 Hz az 1 kHz 25 A az 30 A CMC 0,49 % 50 Hz 2,2 A az 3 A CMC 0,12 % 50 Hz 3 A az 4 A CMC 0,095 % 50 Hz 4 A az 5 A CMC 0,084 % 50 Hz 5 A az 6 A CMC 0,077 % 50 Hz 6 A az 7 A CMC 0,073 % 50 Hz 7 A az 8 A CMC 0,070 % 50 Hz 8 A az 10 A CMC 0,067 % 50 Hz 10 A az 11 A CMC 0,064 % 50 Hz 11 A az 15 A CMC 0,10 % 50 Hz 15 A az 20 A CMC 0,081 % 50 Hz 20 A az 90 A CMC 0,090 % TP4, TP21","search_en":"AC current / AC current meters Calibration – electrical quantities Direct generation with a calibrator 10 Hz to 20 Hz 10 µA to 20 µA CMC 40 nA 20 Hz to 40 Hz 10 µA to 20 µA CMC 28 nA 40 Hz to 1 kHz 10 µA to 20 µA CMC 18 nA 1 kHz to 5 kHz 10 µA to 20 µA CMC 47 nA 5 kHz to 10 kHz 10 µA to 20 µA CMC 97 nA 10 Hz to 20 Hz 20 µA to 30 µA CMC 0,20 % 20 Hz to 40 Hz 20 µA to 30 µA CMC 0,14 % 40 Hz to 1 kHz 20 µA to 30 µA CMC 0,095 % 1 kHz to 5 kHz 20 µA to 30 µA CMC 0,26 % 5 kHz to 10 kHz 20 µA to 30 µA CMC 0,57 % 10 Hz to 20 Hz 30 µA to 40 µA CMC 0,16 % 20 Hz to 40 Hz 30 µA to 40 µA CMC 0,11 % 40 Hz to 1 kHz 30 µA to 40 µA CMC 0,069 % 1 kHz to 5 kHz 30 µA to 40 µA CMC 0,20 % 5 kHz to 10 kHz 30 µA to 40 µA CMC 0,43 % 10 Hz to 20 Hz 40 µA to 50 µA CMC 0,14 % 20 Hz to 40 Hz 40 µA to 50 µA CMC 0,086 % 40 Hz to 1 kHz 40 µA to 50 µA CMC 0,055 % 1 kHz to 5 kHz 40 µA to 50 µA CMC 0,17 % 5 kHz to 10 kHz 40 µA to 50 µA CMC 0,37 % 10 Hz to 20 Hz 50 µA to 60 µA CMC 0,13 % 20 Hz to 40 Hz 50 µA to 60 µA CMC 0,076 % 40 Hz to 1 kHz 50 µA to 60 µA CMC 0,048 % 1 kHz to 5 kHz 50 µA to 60 µA CMC 0,15 % 5 kHz to 10 kHz 50 µA to 60 µA CMC 0,33 % 10 Hz to 20 Hz 60 µA to 80 µA CMC 0,12 % 20 Hz to 40 Hz 60 µA to 80 µA CMC 0,070 % 40 Hz to 1 kHz 60 µA to 80 µA CMC 0,042 % 1 kHz to 5 kHz 60 µA to 80 µA CMC 0,13 % 5 kHz to 10 kHz 60 µA to 80 µA CMC 0,30 % 10 Hz to 20 Hz 80 µA to 100 µA CMC 0,099 % 20 Hz to 40 Hz 80 µA to 100 µA CMC 0,061 % 40 Hz to 1 kHz 80 µA to 100 µA CMC 0,036 % 1 kHz to 5 kHz 80 µA to 100 µA CMC 0,12 % 5 kHz to 10 kHz 80 µA to 100 µA CMC 0,27 % 10 Hz to 20 Hz 100 µA to 130 µA CMC 0,096 % 20 Hz to 40 Hz 100 µA to 130 µA CMC 0,056 % 40 Hz to 1 kHz 100 µA to 130 µA CMC 0,032 % 1 kHz to 5 kHz 100 µA to 130 µA CMC 0,11 % 5 kHz to 10 kHz 100 µA to 130 µA CMC 0,25 % 10 Hz to 20 Hz 130 µA to 180 µA CMC 0,090 % 20 Hz to 40 Hz 130 µA to 180 µA CMC 0,052 % 40 Hz to 1 kHz 130 µA to 180 µA CMC 0,029 % 1 kHz to 5 kHz 130 µA to 180 µA CMC 0,092 % 5 kHz to 10 kHz 130 µA to 180 µA CMC 0,23 % 10 Hz to 20 Hz 180 µA to 220 µA CMC 0,085 % 20 Hz to 40 Hz 180 µA to 220 µA CMC 0,048 % 40 Hz to 1 kHz 180 µA to 220 µA CMC 0,025 % 1 kHz to 5 kHz 180 µA to 220 µA CMC 0,084 % 5 kHz to 10 kHz 180 µA to 220 µA CMC 0,21 % 10 Hz to 20 Hz 220 µA to 300 µA CMC 0,089 % 20 Hz to 40 Hz 220 µA to 300 µA CMC 0,052 % 40 Hz to 1 kHz 220 µA to 300 µA CMC 0,032 % 1 kHz to 5 kHz 220 µA to 300 µA CMC 0,25 % 5 kHz to 10 kHz 220 µA to 300 µA CMC 0,53 % 10 Hz to 20 Hz 300 µA to 400 µA CMC 0,084 % 20 Hz to 40 Hz 300 µA to 400 µA CMC 0,048 % 40 Hz to 1 kHz 300 µA to 400 µA CMC 0,028 % 1 kHz to 5 kHz 300 µA to 400 µA CMC 0,20 % 5 kHz to 10 kHz 300 µA to 400 µA CMC 0,43 % 10 Hz to 20 Hz 400 µA to 500 µA CMC 0,081 % 20 Hz to 40 Hz 400 µA to 500 µA CMC 0,045 % 40 Hz to 1 kHz 400 µA to 500 µA CMC 0,025 % 1 kHz to 5 kHz 400 µA to 500 µA CMC 0,17 % 5 kHz to 10 kHz 400 µA to 500 µA CMC 0,37 % 10 Hz to 20 Hz 500 µA to 600 µA CMC 0,079 % 20 Hz to 40 Hz 500 µA to 600 µA CMC 0,044 % 40 Hz to 1 kHz 500 µA to 600 µA CMC 0,023 % 1 kHz to 5 kHz 500 µA to 600 µA CMC 0,15 % 5 kHz to 10 kHz 500 µA to 600 µA CMC 0,33 % 10 Hz to 20 Hz 600 µA to 800 µA CMC 0,078 % 20 Hz to 40 Hz 600 µA to 800 µA CMC 0,043 % 40 Hz to 1 kHz 600 µA to 800 µA CMC 0,022 % 1 kHz to 5 kHz 600 µA to 800 µA CMC 0,13 % 5 kHz to 10 kHz 600 µA to 800 µA CMC 0,30 % 10 Hz to 20 Hz 800 µA to 1 mA CMC 0,076 % 20 Hz to 40 Hz 800 µA to 1 mA CMC 0,041 % 40 Hz to 1 kHz 800 µA to 1 mA CMC 0,021 % 1 kHz to 5 kHz 800 µA to 1 mA CMC 0,12 % 5 kHz to 10 kHz 800 µA to 1 mA CMC 0,27 % 10 Hz to 20 Hz 1 mA to 1,3 mA CMC 0,075 % 20 Hz to 40 Hz 1 mA to 1,3 mA CMC 0,040 % 40 Hz to 1 kHz 1 mA to 1,3 mA CMC 0,020 % 1 kHz to 5 kHz 1 mA to 1,3 mA CMC 0,11 % 5 kHz to 10 kHz 1 mA to 1,3 mA CMC 0,25 % 10 Hz to 20 Hz 1,3 mA to 1,8 mA CMC 0,074 % 20 Hz to 40 Hz 1,3 mA to 1,8 mA CMC 0,039 % 40 Hz to 1 kHz 1,3 mA to 1,8 mA CMC 0,019 % 1 kHz to 5 kHz 1,3 mA to 1,8 mA CMC 0,092 % 5 kHz to 10 kHz 1,3 mA to 1,8 mA CMC 0,23 % 10 Hz to 20 Hz 1,8 mA to 2,2 mA CMC 0,073 % 20 Hz to 40 Hz 1,8 mA to 2,2 mA CMC 0,074 % 40 Hz to 1 kHz 1,8 mA to 2,2 mA CMC 0,019 % 1 kHz to 5 kHz 1,8 mA to 2,2 mA CMC 0,084 % 5 kHz to 10 kHz 1,8 mA to 2,2 mA CMC 0,21 % 10 Hz to 20 Hz 2,2 mA to 3 mA CMC 0,089 % 20 Hz to 40 Hz 2,2 mA to 3 mA CMC 0,052 % 40 Hz to 1 kHz 2,2 mA to 3 mA CMC 0,032 % 1 kHz to 5 kHz 2,2 mA to 3 mA CMC 0,25 % 5 kHz to 10 kHz 2,2 mA to 3 mA CMC 0,53 % 10 Hz to 20 Hz 3 mA to 4 mA CMC 0,084 % 20 Hz to 40 Hz 3 mA to 4 mA CMC 0,048 % 40 Hz to 1 kHz 3 mA to 4 mA CMC 0,028 % 1 kHz to 5 kHz 3 mA to 4 mA CMC 0,20 % 5 kHz to 10 kHz 3 mA to 4 mA CMC 0,43 % 10 Hz to 20 Hz 4 mA to 5 mA CMC 0,081 % 20 Hz to 40 Hz 4 mA to 5 mA CMC 0,045 % 40 Hz to 1 kHz 4 mA to 5 mA CMC 0,025 % 1 kHz to 5 kHz 4 mA to 5 mA CMC 0,17 % 5 kHz to 10 kHz 4 mA to 5 mA CMC 0,37 % 10 Hz to 20 Hz 5 mA to 6 mA CMC 0,079 % 20 Hz to 40 Hz 5 mA to 6 mA CMC 0,043 % 40 Hz to 1 kHz 5 mA to 6 mA CMC 0,023 % 1 kHz to 5 kHz 5 mA to 6 mA CMC 0,15 % 5 kHz to 10 kHz 5 mA to 6 mA CMC 0,33 % 10 Hz to 20 Hz 6 mA to 8 mA CMC 0,078 % 20 Hz to 40 Hz 6 mA to 8 mA CMC 0,042 % 40 Hz to 1 kHz 6 mA to 8 mA CMC 0,022 % 1 kHz to 5 kHz 6 mA to 8 mA CMC 0,13 % 5 kHz to 10 kHz 6 mA to 8 mA CMC 0,30 % 10 Hz to 20 Hz 8 mA to 10 mA CMC 0,076 % 20 Hz to 40 Hz 8 mA to 10 mA CMC 0,041 % 40 Hz to 1 kHz 8 mA to 10 mA CMC 0,021 % 1 kHz to 5 kHz 8 mA to 10 mA CMC 0,12 % 5 kHz to 10 kHz 8 mA to 10 mA CMC 0,27 % 10 Hz to 20 Hz 10 mA to 13 mA CMC 0,075 % 20 Hz to 40 Hz 10 mA to 13 mA CMC 0,040 % 40 Hz to 1 kHz 10 mA to 13 mA CMC 0,020 % 1 kHz to 5 kHz 10 mA to 13 mA CMC 0,11 % 5 kHz to 10 kHz 10 mA to 13 mA CMC 0,25 % 10 Hz to 20 Hz 13 mA to 18 mA CMC 0,074 % 20 Hz to 40 Hz 13 mA to 18 mA CMC 0,039 % 40 Hz to 1 kHz 13 mA to 18 mA CMC 0,019 % 1 kHz to 5 kHz 13 mA to 18 mA CMC 0,092 % 5 kHz to 10 kHz 13 mA to 18 mA CMC 0,23 % 10 Hz to 20 Hz 18 mA to 22 mA CMC 0,073 % 20 Hz to 40 Hz 18 mA to 22 mA CMC 0,039 % 40 Hz to 1 kHz 18 mA to 22 mA CMC 0,019 % 1 kHz to 5 kHz 18 mA to 22 mA CMC 0,084 % 5 kHz to 10 kHz 18 mA to 22 mA CMC 0,21 % 10 Hz to 20 Hz 22 mA to 30 mA CMC 0,089 % 20 Hz to 40 Hz 22 mA to 30 mA CMC 0,052 % 40 Hz to 1 kHz 22 mA to 30 mA CMC 0,032 % 1 kHz to 5 kHz 22 mA to 30 mA CMC 0,25 % 5 kHz to 10 kHz 22 mA to 30 mA CMC 0,53 % 10 Hz to 20 Hz 30 mA to 40 mA CMC 0,084 % 20 Hz to 40 Hz 30 mA to 40 mA CMC 0,048 % 40 Hz to 1 kHz 30 mA to 40 mA CMC 0,028 % 1 kHz to 5 kHz 30 mA to 40 mA CMC 0,20 % 5 kHz to 10 kHz 30 mA to 40 mA CMC 0,43 % 10 Hz to 20 Hz 40 mA to 50 mA CMC 0,081 % 20 Hz to 40 Hz 40 mA to 50 mA CMC 0,045 % 40 Hz to 1 kHz 40 mA to 50 mA CMC 0,025 % 1 kHz to 5 kHz 40 mA to 50 mA CMC 0,17 % 5 kHz to 10 kHz 40 mA to 50 mA CMC 0,37 % 10 Hz to 20 Hz 50 mA to 60 mA CMC 0,079 % 20 Hz to 40 Hz 50 mA to 60 mA CMC 0,043 % 40 Hz to 1 kHz 50 mA to 60 mA CMC 0,023 % 1 kHz to 5 kHz 50 mA to 60 mA CMC 0,15 % 5 kHz to 10 kHz 50 mA to 60 mA CMC 0,33 % 10 Hz to 20 Hz 60 mA to 80 mA CMC 0,078 % 20 Hz to 40 Hz 60 mA to 80 mA CMC 0,042 % 40 Hz to 1 kHz 60 mA to 80 mA CMC 0,022 % 1 kHz to 5 kHz 60 mA to 80 mA CMC 0,13 % 5 kHz to 10 kHz 60 mA to 80 mA CMC 0,30 % 10 Hz to 20 Hz 80 mA to 100 mA CMC 0,076 % 20 Hz to 40 Hz 80 mA to 100 mA CMC 0,041 % 40 Hz to 1 kHz 80 mA to 100 mA CMC 0,021 % 1 kHz to 5 kHz 80 mA to 100 mA CMC 0,12 % 5 kHz to 10 kHz 80 mA to 100 mA CMC 0,27 % 10 Hz to 20 Hz 100 mA to 130 mA CMC 0,075 % 20 Hz to 40 Hz 100 mA to 130 mA CMC 0,040 % 40 Hz to 1 kHz 100 mA to 130 mA CMC 0,020 % 1 kHz to 5 kHz 100 mA to 130 mA CMC 0,11 % 5 kHz to 10 kHz 100 mA to 130 mA CMC 0,25 % 10 Hz to 20 Hz 130 mA to 180 mA CMC 0,074 % 20 Hz to 40 Hz 130 mA to 180 mA CMC 0,039 % 40 Hz to 1 kHz 130 mA to 180 mA CMC 0,019 % 1 kHz to 5 kHz 130 mA to 180 mA CMC 0,092 % 5 kHz to 10 kHz 130 mA to 180 mA CMC 0,24 % 10 Hz to 20 Hz 180 mA to 220 mA CMC 0,073 % 20 Hz to 40 Hz 180 mA to 220 mA CMC 0,038 % 40 Hz to 1 kHz 180 mA to 220 mA CMC 0,019 % 1 kHz to 5 kHz 180 mA to 220 mA CMC 0,084 % 5 kHz to 10 kHz 180 mA to 220 mA CMC 0,21 % 20 Hz to 1 kHz 220 mA to 300 mA CMC 0,082 % 1 kHz to 5 kHz 220 mA to 300 mA CMC 0,12 % 5 kHz to 10 kHz 220 mA to 300 mA CMC 0,93 % 20 Hz to 1 kHz 300 mA to 400 mA CMC 0,078 % 1 kHz to 5 kHz 300 mA to 400 mA CMC 0,11 % 5 kHz to 10 kHz 300 mA to 400 mA CMC 0,91 % 20 Hz to 1 kHz 400 mA to 500 mA CMC 0,075 % 1 kHz to 5 kHz 400 mA to 500 mA CMC 0,098 % 5 kHz to 10 kHz 400 mA to 500 mA CMC 0,90 % 20 Hz to 1 kHz 500 mA to 600 mA CMC 0,074 % 1 kHz to 5 kHz 500 mA to 600 mA CMC 0,094 % 5 kHz to 10 kHz 500 mA to 600 mA CMC 0,89 % 20 Hz to 1 kHz 600 mA to 1 A CMC 0,072 % 1 kHz to 5 kHz 600 mA to 1 A CMC 0,092 % 5 kHz to 10 kHz 600 mA to 1 A CMC 0,89 % 20 Hz to 1 kHz 1 A to 2,2 A CMC 0,070 % 1 kHz to 5 kHz 1 A to 2,2 A CMC 0,086 % 5 kHz to 10 kHz 1 A to 2,2 A CMC 0,88 % 10 Hz to 1 kHz 2,2 A to 3 A CMC 0,16 % 1 kHz to 5 kHz 2,2 A to 3 A CMC 0,22 % 5 kHz to 10 kHz 2,2 A to 3 A CMC 0,60 % 10 Hz to 1 kHz 3 A to 5 A CMC 0,14 % 1 kHz to 5 kHz 3 A to 5 A CMC 0,20 % 5 kHz to 10 kHz 3 A to 5 A CMC 0,51 % 10 Hz to 1 kHz 5 A to 11 A CMC 0,13 % 1 kHz to 5 kHz 5 A to 11 A CMC 0,18 % 5 kHz to 10 kHz 5 A to 11 A CMC 0,42 % 30 Hz to 45 Hz 11 A to 15 A CMC 0,23 % 45 Hz to 100 Hz 11 A to 15 A CMC 0,12 % 100 Hz to 1 kHz 11 A to 15 A CMC 0,52 % 30 Hz to 45 Hz 15 A to 25 A CMC 0,22 % 45 Hz to 100 Hz 15 A to 25 A CMC 0,12 % 100 Hz to 1 kHz 15 A to 25 A CMC 0,51 % 30 Hz to 45 Hz 25 A to 30 A CMC 0,21 % 45 Hz to 100 Hz 25 A to 30 A CMC 0,11 % 100 Hz to 1 kHz 25 A to 30 A CMC 0,49 % 50 Hz 2,2 A to 3 A CMC 0,12 % 50 Hz 3 A to 4 A CMC 0,095 % 50 Hz 4 A to 5 A CMC 0,084 % 50 Hz 5 A to 6 A CMC 0,077 % 50 Hz 6 A to 7 A CMC 0,073 % 50 Hz 7 A to 8 A CMC 0,070 % 50 Hz 8 A to 10 A CMC 0,067 % 50 Hz 10 A to 11 A CMC 0,064 % 50 Hz 11 A to 15 A CMC 0,10 % 50 Hz 15 A to 20 A CMC 0,081 % 50 Hz 20 A to 90 A CMC 0,090 % TP4, TP21","search_zh":"交流电流 / 交流电流测量仪器 校准 – 电学量 用校准器直接产生 10 Hz 至 20 Hz 10 µA 至 20 µA CMC 40 nA 20 Hz 至 40 Hz 10 µA 至 20 µA CMC 28 nA 40 Hz 至 1 kHz 10 µA 至 20 µA CMC 18 nA 1 kHz 至 5 kHz 10 µA 至 20 µA CMC 47 nA 5 kHz 至 10 kHz 10 µA 至 20 µA CMC 97 nA 10 Hz 至 20 Hz 20 µA 至 30 µA CMC 0,20 % 20 Hz 至 40 Hz 20 µA 至 30 µA CMC 0,14 % 40 Hz 至 1 kHz 20 µA 至 30 µA CMC 0,095 % 1 kHz 至 5 kHz 20 µA 至 30 µA CMC 0,26 % 5 kHz 至 10 kHz 20 µA 至 30 µA CMC 0,57 % 10 Hz 至 20 Hz 30 µA 至 40 µA CMC 0,16 % 20 Hz 至 40 Hz 30 µA 至 40 µA CMC 0,11 % 40 Hz 至 1 kHz 30 µA 至 40 µA CMC 0,069 % 1 kHz 至 5 kHz 30 µA 至 40 µA CMC 0,20 % 5 kHz 至 10 kHz 30 µA 至 40 µA CMC 0,43 % 10 Hz 至 20 Hz 40 µA 至 50 µA CMC 0,14 % 20 Hz 至 40 Hz 40 µA 至 50 µA CMC 0,086 % 40 Hz 至 1 kHz 40 µA 至 50 µA CMC 0,055 % 1 kHz 至 5 kHz 40 µA 至 50 µA CMC 0,17 % 5 kHz 至 10 kHz 40 µA 至 50 µA CMC 0,37 % 10 Hz 至 20 Hz 50 µA 至 60 µA CMC 0,13 % 20 Hz 至 40 Hz 50 µA 至 60 µA CMC 0,076 % 40 Hz 至 1 kHz 50 µA 至 60 µA CMC 0,048 % 1 kHz 至 5 kHz 50 µA 至 60 µA CMC 0,15 % 5 kHz 至 10 kHz 50 µA 至 60 µA CMC 0,33 % 10 Hz 至 20 Hz 60 µA 至 80 µA CMC 0,12 % 20 Hz 至 40 Hz 60 µA 至 80 µA CMC 0,070 % 40 Hz 至 1 kHz 60 µA 至 80 µA CMC 0,042 % 1 kHz 至 5 kHz 60 µA 至 80 µA CMC 0,13 % 5 kHz 至 10 kHz 60 µA 至 80 µA CMC 0,30 % 10 Hz 至 20 Hz 80 µA 至 100 µA CMC 0,099 % 20 Hz 至 40 Hz 80 µA 至 100 µA CMC 0,061 % 40 Hz 至 1 kHz 80 µA 至 100 µA CMC 0,036 % 1 kHz 至 5 kHz 80 µA 至 100 µA CMC 0,12 % 5 kHz 至 10 kHz 80 µA 至 100 µA CMC 0,27 % 10 Hz 至 20 Hz 100 µA 至 130 µA CMC 0,096 % 20 Hz 至 40 Hz 100 µA 至 130 µA CMC 0,056 % 40 Hz 至 1 kHz 100 µA 至 130 µA CMC 0,032 % 1 kHz 至 5 kHz 100 µA 至 130 µA CMC 0,11 % 5 kHz 至 10 kHz 100 µA 至 130 µA CMC 0,25 % 10 Hz 至 20 Hz 130 µA 至 180 µA CMC 0,090 % 20 Hz 至 40 Hz 130 µA 至 180 µA CMC 0,052 % 40 Hz 至 1 kHz 130 µA 至 180 µA CMC 0,029 % 1 kHz 至 5 kHz 130 µA 至 180 µA CMC 0,092 % 5 kHz 至 10 kHz 130 µA 至 180 µA CMC 0,23 % 10 Hz 至 20 Hz 180 µA 至 220 µA CMC 0,085 % 20 Hz 至 40 Hz 180 µA 至 220 µA CMC 0,048 % 40 Hz 至 1 kHz 180 µA 至 220 µA CMC 0,025 % 1 kHz 至 5 kHz 180 µA 至 220 µA CMC 0,084 % 5 kHz 至 10 kHz 180 µA 至 220 µA CMC 0,21 % 10 Hz 至 20 Hz 220 µA 至 300 µA CMC 0,089 % 20 Hz 至 40 Hz 220 µA 至 300 µA CMC 0,052 % 40 Hz 至 1 kHz 220 µA 至 300 µA CMC 0,032 % 1 kHz 至 5 kHz 220 µA 至 300 µA CMC 0,25 % 5 kHz 至 10 kHz 220 µA 至 300 µA CMC 0,53 % 10 Hz 至 20 Hz 300 µA 至 400 µA CMC 0,084 % 20 Hz 至 40 Hz 300 µA 至 400 µA CMC 0,048 % 40 Hz 至 1 kHz 300 µA 至 400 µA CMC 0,028 % 1 kHz 至 5 kHz 300 µA 至 400 µA CMC 0,20 % 5 kHz 至 10 kHz 300 µA 至 400 µA CMC 0,43 % 10 Hz 至 20 Hz 400 µA 至 500 µA CMC 0,081 % 20 Hz 至 40 Hz 400 µA 至 500 µA CMC 0,045 % 40 Hz 至 1 kHz 400 µA 至 500 µA CMC 0,025 % 1 kHz 至 5 kHz 400 µA 至 500 µA CMC 0,17 % 5 kHz 至 10 kHz 400 µA 至 500 µA CMC 0,37 % 10 Hz 至 20 Hz 500 µA 至 600 µA CMC 0,079 % 20 Hz 至 40 Hz 500 µA 至 600 µA CMC 0,044 % 40 Hz 至 1 kHz 500 µA 至 600 µA CMC 0,023 % 1 kHz 至 5 kHz 500 µA 至 600 µA CMC 0,15 % 5 kHz 至 10 kHz 500 µA 至 600 µA CMC 0,33 % 10 Hz 至 20 Hz 600 µA 至 800 µA CMC 0,078 % 20 Hz 至 40 Hz 600 µA 至 800 µA CMC 0,043 % 40 Hz 至 1 kHz 600 µA 至 800 µA CMC 0,022 % 1 kHz 至 5 kHz 600 µA 至 800 µA CMC 0,13 % 5 kHz 至 10 kHz 600 µA 至 800 µA CMC 0,30 % 10 Hz 至 20 Hz 800 µA 至 1 mA CMC 0,076 % 20 Hz 至 40 Hz 800 µA 至 1 mA CMC 0,041 % 40 Hz 至 1 kHz 800 µA 至 1 mA CMC 0,021 % 1 kHz 至 5 kHz 800 µA 至 1 mA CMC 0,12 % 5 kHz 至 10 kHz 800 µA 至 1 mA CMC 0,27 % 10 Hz 至 20 Hz 1 mA 至 1,3 mA CMC 0,075 % 20 Hz 至 40 Hz 1 mA 至 1,3 mA CMC 0,040 % 40 Hz 至 1 kHz 1 mA 至 1,3 mA CMC 0,020 % 1 kHz 至 5 kHz 1 mA 至 1,3 mA CMC 0,11 % 5 kHz 至 10 kHz 1 mA 至 1,3 mA CMC 0,25 % 10 Hz 至 20 Hz 1,3 mA 至 1,8 mA CMC 0,074 % 20 Hz 至 40 Hz 1,3 mA 至 1,8 mA CMC 0,039 % 40 Hz 至 1 kHz 1,3 mA 至 1,8 mA CMC 0,019 % 1 kHz 至 5 kHz 1,3 mA 至 1,8 mA CMC 0,092 % 5 kHz 至 10 kHz 1,3 mA 至 1,8 mA CMC 0,23 % 10 Hz 至 20 Hz 1,8 mA 至 2,2 mA CMC 0,073 % 20 Hz 至 40 Hz 1,8 mA 至 2,2 mA CMC 0,074 % 40 Hz 至 1 kHz 1,8 mA 至 2,2 mA CMC 0,019 % 1 kHz 至 5 kHz 1,8 mA 至 2,2 mA CMC 0,084 % 5 kHz 至 10 kHz 1,8 mA 至 2,2 mA CMC 0,21 % 10 Hz 至 20 Hz 2,2 mA 至 3 mA CMC 0,089 % 20 Hz 至 40 Hz 2,2 mA 至 3 mA CMC 0,052 % 40 Hz 至 1 kHz 2,2 mA 至 3 mA CMC 0,032 % 1 kHz 至 5 kHz 2,2 mA 至 3 mA CMC 0,25 % 5 kHz 至 10 kHz 2,2 mA 至 3 mA CMC 0,53 % 10 Hz 至 20 Hz 3 mA 至 4 mA CMC 0,084 % 20 Hz 至 40 Hz 3 mA 至 4 mA CMC 0,048 % 40 Hz 至 1 kHz 3 mA 至 4 mA CMC 0,028 % 1 kHz 至 5 kHz 3 mA 至 4 mA CMC 0,20 % 5 kHz 至 10 kHz 3 mA 至 4 mA CMC 0,43 % 10 Hz 至 20 Hz 4 mA 至 5 mA CMC 0,081 % 20 Hz 至 40 Hz 4 mA 至 5 mA CMC 0,045 % 40 Hz 至 1 kHz 4 mA 至 5 mA CMC 0,025 % 1 kHz 至 5 kHz 4 mA 至 5 mA CMC 0,17 % 5 kHz 至 10 kHz 4 mA 至 5 mA CMC 0,37 % 10 Hz 至 20 Hz 5 mA 至 6 mA CMC 0,079 % 20 Hz 至 40 Hz 5 mA 至 6 mA CMC 0,043 % 40 Hz 至 1 kHz 5 mA 至 6 mA CMC 0,023 % 1 kHz 至 5 kHz 5 mA 至 6 mA CMC 0,15 % 5 kHz 至 10 kHz 5 mA 至 6 mA CMC 0,33 % 10 Hz 至 20 Hz 6 mA 至 8 mA CMC 0,078 % 20 Hz 至 40 Hz 6 mA 至 8 mA CMC 0,042 % 40 Hz 至 1 kHz 6 mA 至 8 mA CMC 0,022 % 1 kHz 至 5 kHz 6 mA 至 8 mA CMC 0,13 % 5 kHz 至 10 kHz 6 mA 至 8 mA CMC 0,30 % 10 Hz 至 20 Hz 8 mA 至 10 mA CMC 0,076 % 20 Hz 至 40 Hz 8 mA 至 10 mA CMC 0,041 % 40 Hz 至 1 kHz 8 mA 至 10 mA CMC 0,021 % 1 kHz 至 5 kHz 8 mA 至 10 mA CMC 0,12 % 5 kHz 至 10 kHz 8 mA 至 10 mA CMC 0,27 % 10 Hz 至 20 Hz 10 mA 至 13 mA CMC 0,075 % 20 Hz 至 40 Hz 10 mA 至 13 mA CMC 0,040 % 40 Hz 至 1 kHz 10 mA 至 13 mA CMC 0,020 % 1 kHz 至 5 kHz 10 mA 至 13 mA CMC 0,11 % 5 kHz 至 10 kHz 10 mA 至 13 mA CMC 0,25 % 10 Hz 至 20 Hz 13 mA 至 18 mA CMC 0,074 % 20 Hz 至 40 Hz 13 mA 至 18 mA CMC 0,039 % 40 Hz 至 1 kHz 13 mA 至 18 mA CMC 0,019 % 1 kHz 至 5 kHz 13 mA 至 18 mA CMC 0,092 % 5 kHz 至 10 kHz 13 mA 至 18 mA CMC 0,23 % 10 Hz 至 20 Hz 18 mA 至 22 mA CMC 0,073 % 20 Hz 至 40 Hz 18 mA 至 22 mA CMC 0,039 % 40 Hz 至 1 kHz 18 mA 至 22 mA CMC 0,019 % 1 kHz 至 5 kHz 18 mA 至 22 mA CMC 0,084 % 5 kHz 至 10 kHz 18 mA 至 22 mA CMC 0,21 % 10 Hz 至 20 Hz 22 mA 至 30 mA CMC 0,089 % 20 Hz 至 40 Hz 22 mA 至 30 mA CMC 0,052 % 40 Hz 至 1 kHz 22 mA 至 30 mA CMC 0,032 % 1 kHz 至 5 kHz 22 mA 至 30 mA CMC 0,25 % 5 kHz 至 10 kHz 22 mA 至 30 mA CMC 0,53 % 10 Hz 至 20 Hz 30 mA 至 40 mA CMC 0,084 % 20 Hz 至 40 Hz 30 mA 至 40 mA CMC 0,048 % 40 Hz 至 1 kHz 30 mA 至 40 mA CMC 0,028 % 1 kHz 至 5 kHz 30 mA 至 40 mA CMC 0,20 % 5 kHz 至 10 kHz 30 mA 至 40 mA CMC 0,43 % 10 Hz 至 20 Hz 40 mA 至 50 mA CMC 0,081 % 20 Hz 至 40 Hz 40 mA 至 50 mA CMC 0,045 % 40 Hz 至 1 kHz 40 mA 至 50 mA CMC 0,025 % 1 kHz 至 5 kHz 40 mA 至 50 mA CMC 0,17 % 5 kHz 至 10 kHz 40 mA 至 50 mA CMC 0,37 % 10 Hz 至 20 Hz 50 mA 至 60 mA CMC 0,079 % 20 Hz 至 40 Hz 50 mA 至 60 mA CMC 0,043 % 40 Hz 至 1 kHz 50 mA 至 60 mA CMC 0,023 % 1 kHz 至 5 kHz 50 mA 至 60 mA CMC 0,15 % 5 kHz 至 10 kHz 50 mA 至 60 mA CMC 0,33 % 10 Hz 至 20 Hz 60 mA 至 80 mA CMC 0,078 % 20 Hz 至 40 Hz 60 mA 至 80 mA CMC 0,042 % 40 Hz 至 1 kHz 60 mA 至 80 mA CMC 0,022 % 1 kHz 至 5 kHz 60 mA 至 80 mA CMC 0,13 % 5 kHz 至 10 kHz 60 mA 至 80 mA CMC 0,30 % 10 Hz 至 20 Hz 80 mA 至 100 mA CMC 0,076 % 20 Hz 至 40 Hz 80 mA 至 100 mA CMC 0,041 % 40 Hz 至 1 kHz 80 mA 至 100 mA CMC 0,021 % 1 kHz 至 5 kHz 80 mA 至 100 mA CMC 0,12 % 5 kHz 至 10 kHz 80 mA 至 100 mA CMC 0,27 % 10 Hz 至 20 Hz 100 mA 至 130 mA CMC 0,075 % 20 Hz 至 40 Hz 100 mA 至 130 mA CMC 0,040 % 40 Hz 至 1 kHz 100 mA 至 130 mA CMC 0,020 % 1 kHz 至 5 kHz 100 mA 至 130 mA CMC 0,11 % 5 kHz 至 10 kHz 100 mA 至 130 mA CMC 0,25 % 10 Hz 至 20 Hz 130 mA 至 180 mA CMC 0,074 % 20 Hz 至 40 Hz 130 mA 至 180 mA CMC 0,039 % 40 Hz 至 1 kHz 130 mA 至 180 mA CMC 0,019 % 1 kHz 至 5 kHz 130 mA 至 180 mA CMC 0,092 % 5 kHz 至 10 kHz 130 mA 至 180 mA CMC 0,24 % 10 Hz 至 20 Hz 180 mA 至 220 mA CMC 0,073 % 20 Hz 至 40 Hz 180 mA 至 220 mA CMC 0,038 % 40 Hz 至 1 kHz 180 mA 至 220 mA CMC 0,019 % 1 kHz 至 5 kHz 180 mA 至 220 mA CMC 0,084 % 5 kHz 至 10 kHz 180 mA 至 220 mA CMC 0,21 % 20 Hz 至 1 kHz 220 mA 至 300 mA CMC 0,082 % 1 kHz 至 5 kHz 220 mA 至 300 mA CMC 0,12 % 5 kHz 至 10 kHz 220 mA 至 300 mA CMC 0,93 % 20 Hz 至 1 kHz 300 mA 至 400 mA CMC 0,078 % 1 kHz 至 5 kHz 300 mA 至 400 mA CMC 0,11 % 5 kHz 至 10 kHz 300 mA 至 400 mA CMC 0,91 % 20 Hz 至 1 kHz 400 mA 至 500 mA CMC 0,075 % 1 kHz 至 5 kHz 400 mA 至 500 mA CMC 0,098 % 5 kHz 至 10 kHz 400 mA 至 500 mA CMC 0,90 % 20 Hz 至 1 kHz 500 mA 至 600 mA CMC 0,074 % 1 kHz 至 5 kHz 500 mA 至 600 mA CMC 0,094 % 5 kHz 至 10 kHz 500 mA 至 600 mA CMC 0,89 % 20 Hz 至 1 kHz 600 mA 至 1 A CMC 0,072 % 1 kHz 至 5 kHz 600 mA 至 1 A CMC 0,092 % 5 kHz 至 10 kHz 600 mA 至 1 A CMC 0,89 % 20 Hz 至 1 kHz 1 A 至 2,2 A CMC 0,070 % 1 kHz 至 5 kHz 1 A 至 2,2 A CMC 0,086 % 5 kHz 至 10 kHz 1 A 至 2,2 A CMC 0,88 % 10 Hz 至 1 kHz 2,2 A 至 3 A CMC 0,16 % 1 kHz 至 5 kHz 2,2 A 至 3 A CMC 0,22 % 5 kHz 至 10 kHz 2,2 A 至 3 A CMC 0,60 % 10 Hz 至 1 kHz 3 A 至 5 A CMC 0,14 % 1 kHz 至 5 kHz 3 A 至 5 A CMC 0,20 % 5 kHz 至 10 kHz 3 A 至 5 A CMC 0,51 % 10 Hz 至 1 kHz 5 A 至 11 A CMC 0,13 % 1 kHz 至 5 kHz 5 A 至 11 A CMC 0,18 % 5 kHz 至 10 kHz 5 A 至 11 A CMC 0,42 % 30 Hz 至 45 Hz 11 A 至 15 A CMC 0,23 % 45 Hz 至 100 Hz 11 A 至 15 A CMC 0,12 % 100 Hz 至 1 kHz 11 A 至 15 A CMC 0,52 % 30 Hz 至 45 Hz 15 A 至 25 A CMC 0,22 % 45 Hz 至 100 Hz 15 A 至 25 A CMC 0,12 % 100 Hz 至 1 kHz 15 A 至 25 A CMC 0,51 % 30 Hz 至 45 Hz 25 A 至 30 A CMC 0,21 % 45 Hz 至 100 Hz 25 A 至 30 A CMC 0,11 % 100 Hz 至 1 kHz 25 A 至 30 A CMC 0,49 % 50 Hz 2,2 A 至 3 A CMC 0,12 % 50 Hz 3 A 至 4 A CMC 0,095 % 50 Hz 4 A 至 5 A CMC 0,084 % 50 Hz 5 A 至 6 A CMC 0,077 % 50 Hz 6 A 至 7 A CMC 0,073 % 50 Hz 7 A 至 8 A CMC 0,070 % 50 Hz 8 A 至 10 A CMC 0,067 % 50 Hz 10 A 至 11 A CMC 0,064 % 50 Hz 11 A 至 15 A CMC 0,10 % 50 Hz 15 A 至 20 A CMC 0,081 % 50 Hz 20 A 至 90 A CMC 0,090 % TP4, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc4ab8da57d19939ca1c8c7b","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / Mierniki prądu przemiennego","test_object_en":"AC current / AC current meters","test_object_zh":"交流电流 / 交流电流测量仪器","test_object_cs":"Střídavý proud / Měřidla střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 90 A do 2250 A","cmc":"0,50 %"}],"parameters_en":[{"name":"50 Hz","range":"90 A to 2250 A","cmc":"0,50 %"}],"parameters_zh":[{"name":"50 Hz","range":"90 A 至 2250 A","cmc":"0,50 %"}],"parameters_cs":[{"name":"50 Hz","range":"90 A až 2250 A","cmc":"0,50 %"}],"technique":"Pośrednie generowanie kalibratorem z cewką prądową","technique_en":"Indirect generation with a calibrator with a current coil","technique_zh":"用带电流线圈的校准器间接产生","technique_cs":"Nepřímé generování kalibrátorem s proudovou cívkou","techniques":["Pośrednie generowanie kalibratorem z cewką prądową"],"techniques_en":["Indirect generation with a calibrator with a current coil"],"techniques_zh":["用带电流线圈的校准器间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 90 A do 2250 A CMC 0,50 %\nPośrednie generowanie kalibratorem z cewką prądową","reference":"TP4, TP21","norm_bases":["TP4","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / Mierniki prądu przemiennego Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z cewką prądową 50 Hz od 90 A do 2250 A CMC 0,50 % Střídavý proud / Měřidla střídavého proudu Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem s proudovou cívkou 50 Hz 90 A až 2250 A CMC 0,50 % TP4, TP21 Prad przemienny / Mierniki pradu przemiennego Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z cewka pradowa 50 Hz od 90 A do 2250 A CMC 0,50 % Stridavy proud / Meridla stridaveho proudu Kalibrace – elektricke veliciny Neprime generovani kalibratorem s proudovou civkou 50 Hz 90 A az 2250 A CMC 0,50 % TP4, TP21","search_en":"AC current / AC current meters Calibration – electrical quantities Indirect generation with a calibrator with a current coil 50 Hz 90 A to 2250 A CMC 0,50 % TP4, TP21","search_zh":"交流电流 / 交流电流测量仪器 校准 – 电学量 用带电流线圈的校准器间接产生 50 Hz 90 A 至 2250 A CMC 0,50 % TP4, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed9d37a1b85b06c64ca33a1b","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / Wzorce rezystancji przy prądzie stałym","test_object_en":"DC resistance / DC resistance standards","test_object_zh":"直流电阻 / 直流电阻标准器","test_object_cs":"Stejnosměrný odpor / Etalony stejnosměrného elektrického odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 0,1 Ω","cmc":"6 µΩ"},{"name":"","range":"od 0,1 Ω do 0,5 Ω","cmc":"12 µΩ"},{"name":"","range":"od 0,5 Ω do 1 Ω","cmc":"20 µΩ"},{"name":"","range":"od 1 Ω do 2 Ω","cmc":"0,0020 %"},{"name":"","range":"od 2 Ω do 3 Ω","cmc":"0,0017 %"},{"name":"","range":"od 3 Ω do 5 Ω","cmc":"0,0014 %"},{"name":"","range":"od 5 Ω do 15 Ω","cmc":"0,0012 %"},{"name":"","range":"od 15 Ω do 19 Ω","cmc":"0,0010 %"},{"name":"","range":"od 19 Ω do 20 Ω","cmc":"0,00098 %"},{"name":"","range":"od 20 Ω do 25 Ω","cmc":"0,0011 %"},{"name":"","range":"od 25 Ω do 30 Ω","cmc":"0,00096 %"},{"name":"","range":"od 30 Ω do 50 Ω","cmc":"0,00092 %"},{"name":"","range":"od 50 Ω do 100 Ω","cmc":"0,00086 %"},{"name":"","range":"od 100 Ω do 190 Ω","cmc":"0,00081 %"},{"name":"","range":"od 190 Ω do 200 Ω","cmc":"0,00078 %"},{"name":"","range":"od 200 Ω do 250 Ω","cmc":"0,0011 %"},{"name":"","range":"od 250 Ω do 300 Ω","cmc":"0,00096 %"},{"name":"","range":"od 300 Ω do 500 Ω","cmc":"0,00092 %"},{"name":"","range":"od 500 Ω do 1 kΩ","cmc":"0,00086 %"},{"name":"","range":"od 1 kΩ do 1,9 kΩ","cmc":"0,00081 %"},{"name":"","range":"od 1,9 kΩ do 2 kΩ","cmc":"0,00078 %"},{"name":"","range":"od 2 kΩ do 2,5 kΩ","cmc":"0,0011 %"},{"name":"","range":"od 2,5 kΩ do 3 kΩ","cmc":"0,00096 %"},{"name":"","range":"od 3 kΩ do 5 kΩ","cmc":"0,00092 %"},{"name":"","range":"od 5 kΩ do 10 kΩ","cmc":"0,00086 %"},{"name":"","range":"od 10 kΩ do 19 kΩ","cmc":"0,00081 %"},{"name":"","range":"od 19 kΩ do 20 kΩ","cmc":"0,00078 %"},{"name":"","range":"od 20 kΩ do 25 kΩ","cmc":"0,0011 %"},{"name":"","range":"od 25 kΩ do 30 kΩ","cmc":"0,00096 %"},{"name":"","range":"od 30 kΩ do 50 kΩ","cmc":"0,00092 %"},{"name":"","range":"od 50 kΩ do 100 kΩ","cmc":"0,00086 %"},{"name":"","range":"od 100 kΩ do 190 kΩ","cmc":"0,00081 %"},{"name":"","range":"od 190 kΩ do 200 kΩ","cmc":"0,00078 %"},{"name":"","range":"od 200 kΩ do 300 kΩ","cmc":"0,0014 %"},{"name":"","range":"od 300 kΩ do 1 MΩ","cmc":"0,0012 %"},{"name":"","range":"od 1 MΩ do 1,9 MΩ","cmc":"0,00096 %"},{"name":"","range":"od 1,9 MΩ do 2 MΩ","cmc":"0,00091 %"},{"name":"","range":"od 2 MΩ do 5 MΩ","cmc":"0,0021 %"},{"name":"","range":"od 5 MΩ do 19 MΩ","cmc":"0,0018 %"},{"name":"","range":"od 19 MΩ do 20 MΩ","cmc":"0,0016 %"},{"name":"","range":"od 20 MΩ do 30 MΩ","cmc":"0,012 %"},{"name":"","range":"od 30 MΩ do 50 MΩ","cmc":"0,0094 %"},{"name":"","range":"od 50 MΩ do 100 MΩ","cmc":"0,0081 %"},{"name":"","range":"od 100 MΩ do 190 MΩ","cmc":"0,0071 %"},{"name":"","range":"od 190 MΩ do 200 MΩ","cmc":"0,0066 %"},{"name":"","range":"od 200 MΩ do 250 MΩ","cmc":"0,066 %"},{"name":"","range":"od 250 MΩ do 300 MΩ","cmc":"0,056 %"},{"name":"","range":"od 300 MΩ do 400 MΩ","cmc":"0,049 %"},{"name":"","range":"od 400 MΩ do 500 MΩ","cmc":"0,041 %"},{"name":"","range":"od 500 MΩ do 700 MΩ","cmc":"0,036 %"},{"name":"","range":"od 700 MΩ do 1 GΩ","cmc":"0,030 %"},{"name":"","range":"od 1 GΩ do 1,9 GΩ","cmc":"0,026 %"},{"name":"","range":"od 1,9 GΩ do 2 GΩ","cmc":"0,021 %"},{"name":"","range":"od 2 GΩ do 2,5 GΩ","cmc":"0,56 %"},{"name":"","range":"od 2,5 GΩ do 3 GΩ","cmc":"0,46 %"},{"name":"","range":"od 3 GΩ do 4 GΩ","cmc":"0,39 %"},{"name":"","range":"od 4 GΩ do 5 GΩ","cmc":"0,31 %"},{"name":"","range":"od 5 GΩ do 6 GΩ","cmc":"0,26 %"},{"name":"","range":"od 6 GΩ do 7 GΩ","cmc":"0,23 %"},{"name":"","range":"od 7 GΩ do 10 GΩ","cmc":"0,20 %"},{"name":"","range":"od 10 GΩ do 15 GΩ","cmc":"0,16 %"},{"name":"","range":"od 15 GΩ do 19 GΩ","cmc":"0,13 %"},{"name":"","range":"od 19 GΩ do 20 GΩ","cmc":"0,11 %"}],"parameters_en":[{"name":"","range":"0 Ω to 0,1 Ω","cmc":"6 µΩ"},{"name":"","range":"0,1 Ω to 0,5 Ω","cmc":"12 µΩ"},{"name":"","range":"0,5 Ω to 1 Ω","cmc":"20 µΩ"},{"name":"","range":"1 Ω to 2 Ω","cmc":"0,0020 %"},{"name":"","range":"2 Ω to 3 Ω","cmc":"0,0017 %"},{"name":"","range":"3 Ω to 5 Ω","cmc":"0,0014 %"},{"name":"","range":"5 Ω to 15 Ω","cmc":"0,0012 %"},{"name":"","range":"15 Ω to 19 Ω","cmc":"0,0010 %"},{"name":"","range":"19 Ω to 20 Ω","cmc":"0,00098 %"},{"name":"","range":"20 Ω to 25 Ω","cmc":"0,0011 %"},{"name":"","range":"25 Ω to 30 Ω","cmc":"0,00096 %"},{"name":"","range":"30 Ω to 50 Ω","cmc":"0,00092 %"},{"name":"","range":"50 Ω to 100 Ω","cmc":"0,00086 %"},{"name":"","range":"100 Ω to 190 Ω","cmc":"0,00081 %"},{"name":"","range":"190 Ω to 200 Ω","cmc":"0,00078 %"},{"name":"","range":"200 Ω to 250 Ω","cmc":"0,0011 %"},{"name":"","range":"250 Ω to 300 Ω","cmc":"0,00096 %"},{"name":"","range":"300 Ω to 500 Ω","cmc":"0,00092 %"},{"name":"","range":"500 Ω to 1 kΩ","cmc":"0,00086 %"},{"name":"","range":"1 kΩ to 1,9 kΩ","cmc":"0,00081 %"},{"name":"","range":"1,9 kΩ to 2 kΩ","cmc":"0,00078 %"},{"name":"","range":"2 kΩ to 2,5 kΩ","cmc":"0,0011 %"},{"name":"","range":"2,5 kΩ to 3 kΩ","cmc":"0,00096 %"},{"name":"","range":"3 kΩ to 5 kΩ","cmc":"0,00092 %"},{"name":"","range":"5 kΩ to 10 kΩ","cmc":"0,00086 %"},{"name":"","range":"10 kΩ to 19 kΩ","cmc":"0,00081 %"},{"name":"","range":"19 kΩ to 20 kΩ","cmc":"0,00078 %"},{"name":"","range":"20 kΩ to 25 kΩ","cmc":"0,0011 %"},{"name":"","range":"25 kΩ to 30 kΩ","cmc":"0,00096 %"},{"name":"","range":"30 kΩ to 50 kΩ","cmc":"0,00092 %"},{"name":"","range":"50 kΩ to 100 kΩ","cmc":"0,00086 %"},{"name":"","range":"100 kΩ to 190 kΩ","cmc":"0,00081 %"},{"name":"","range":"190 kΩ to 200 kΩ","cmc":"0,00078 %"},{"name":"","range":"200 kΩ to 300 kΩ","cmc":"0,0014 %"},{"name":"","range":"300 kΩ to 1 MΩ","cmc":"0,0012 %"},{"name":"","range":"1 MΩ to 1,9 MΩ","cmc":"0,00096 %"},{"name":"","range":"1,9 MΩ to 2 MΩ","cmc":"0,00091 %"},{"name":"","range":"2 MΩ to 5 MΩ","cmc":"0,0021 %"},{"name":"","range":"5 MΩ to 19 MΩ","cmc":"0,0018 %"},{"name":"","range":"19 MΩ to 20 MΩ","cmc":"0,0016 %"},{"name":"","range":"20 MΩ to 30 MΩ","cmc":"0,012 %"},{"name":"","range":"30 MΩ to 50 MΩ","cmc":"0,0094 %"},{"name":"","range":"50 MΩ to 100 MΩ","cmc":"0,0081 %"},{"name":"","range":"100 MΩ to 190 MΩ","cmc":"0,0071 %"},{"name":"","range":"190 MΩ to 200 MΩ","cmc":"0,0066 %"},{"name":"","range":"200 MΩ to 250 MΩ","cmc":"0,066 %"},{"name":"","range":"250 MΩ to 300 MΩ","cmc":"0,056 %"},{"name":"","range":"300 MΩ to 400 MΩ","cmc":"0,049 %"},{"name":"","range":"400 MΩ to 500 MΩ","cmc":"0,041 %"},{"name":"","range":"500 MΩ to 700 MΩ","cmc":"0,036 %"},{"name":"","range":"700 MΩ to 1 GΩ","cmc":"0,030 %"},{"name":"","range":"1 GΩ to 1,9 GΩ","cmc":"0,026 %"},{"name":"","range":"1,9 GΩ to 2 GΩ","cmc":"0,021 %"},{"name":"","range":"2 GΩ to 2,5 GΩ","cmc":"0,56 %"},{"name":"","range":"2,5 GΩ to 3 GΩ","cmc":"0,46 %"},{"name":"","range":"3 GΩ to 4 GΩ","cmc":"0,39 %"},{"name":"","range":"4 GΩ to 5 GΩ","cmc":"0,31 %"},{"name":"","range":"5 GΩ to 6 GΩ","cmc":"0,26 %"},{"name":"","range":"6 GΩ to 7 GΩ","cmc":"0,23 %"},{"name":"","range":"7 GΩ to 10 GΩ","cmc":"0,20 %"},{"name":"","range":"10 GΩ to 15 GΩ","cmc":"0,16 %"},{"name":"","range":"15 GΩ to 19 GΩ","cmc":"0,13 %"},{"name":"","range":"19 GΩ to 20 GΩ","cmc":"0,11 %"}],"parameters_zh":[{"name":"","range":"0 Ω 至 0,1 Ω","cmc":"6 µΩ"},{"name":"","range":"0,1 Ω 至 0,5 Ω","cmc":"12 µΩ"},{"name":"","range":"0,5 Ω 至 1 Ω","cmc":"20 µΩ"},{"name":"","range":"1 Ω 至 2 Ω","cmc":"0,0020 %"},{"name":"","range":"2 Ω 至 3 Ω","cmc":"0,0017 %"},{"name":"","range":"3 Ω 至 5 Ω","cmc":"0,0014 %"},{"name":"","range":"5 Ω 至 15 Ω","cmc":"0,0012 %"},{"name":"","range":"15 Ω 至 19 Ω","cmc":"0,0010 %"},{"name":"","range":"19 Ω 至 20 Ω","cmc":"0,00098 %"},{"name":"","range":"20 Ω 至 25 Ω","cmc":"0,0011 %"},{"name":"","range":"25 Ω 至 30 Ω","cmc":"0,00096 %"},{"name":"","range":"30 Ω 至 50 Ω","cmc":"0,00092 %"},{"name":"","range":"50 Ω 至 100 Ω","cmc":"0,00086 %"},{"name":"","range":"100 Ω 至 190 Ω","cmc":"0,00081 %"},{"name":"","range":"190 Ω 至 200 Ω","cmc":"0,00078 %"},{"name":"","range":"200 Ω 至 250 Ω","cmc":"0,0011 %"},{"name":"","range":"250 Ω 至 300 Ω","cmc":"0,00096 %"},{"name":"","range":"300 Ω 至 500 Ω","cmc":"0,00092 %"},{"name":"","range":"500 Ω 至 1 kΩ","cmc":"0,00086 %"},{"name":"","range":"1 kΩ 至 1,9 kΩ","cmc":"0,00081 %"},{"name":"","range":"1,9 kΩ 至 2 kΩ","cmc":"0,00078 %"},{"name":"","range":"2 kΩ 至 2,5 kΩ","cmc":"0,0011 %"},{"name":"","range":"2,5 kΩ 至 3 kΩ","cmc":"0,00096 %"},{"name":"","range":"3 kΩ 至 5 kΩ","cmc":"0,00092 %"},{"name":"","range":"5 kΩ 至 10 kΩ","cmc":"0,00086 %"},{"name":"","range":"10 kΩ 至 19 kΩ","cmc":"0,00081 %"},{"name":"","range":"19 kΩ 至 20 kΩ","cmc":"0,00078 %"},{"name":"","range":"20 kΩ 至 25 kΩ","cmc":"0,0011 %"},{"name":"","range":"25 kΩ 至 30 kΩ","cmc":"0,00096 %"},{"name":"","range":"30 kΩ 至 50 kΩ","cmc":"0,00092 %"},{"name":"","range":"50 kΩ 至 100 kΩ","cmc":"0,00086 %"},{"name":"","range":"100 kΩ 至 190 kΩ","cmc":"0,00081 %"},{"name":"","range":"190 kΩ 至 200 kΩ","cmc":"0,00078 %"},{"name":"","range":"200 kΩ 至 300 kΩ","cmc":"0,0014 %"},{"name":"","range":"300 kΩ 至 1 MΩ","cmc":"0,0012 %"},{"name":"","range":"1 MΩ 至 1,9 MΩ","cmc":"0,00096 %"},{"name":"","range":"1,9 MΩ 至 2 MΩ","cmc":"0,00091 %"},{"name":"","range":"2 MΩ 至 5 MΩ","cmc":"0,0021 %"},{"name":"","range":"5 MΩ 至 19 MΩ","cmc":"0,0018 %"},{"name":"","range":"19 MΩ 至 20 MΩ","cmc":"0,0016 %"},{"name":"","range":"20 MΩ 至 30 MΩ","cmc":"0,012 %"},{"name":"","range":"30 MΩ 至 50 MΩ","cmc":"0,0094 %"},{"name":"","range":"50 MΩ 至 100 MΩ","cmc":"0,0081 %"},{"name":"","range":"100 MΩ 至 190 MΩ","cmc":"0,0071 %"},{"name":"","range":"190 MΩ 至 200 MΩ","cmc":"0,0066 %"},{"name":"","range":"200 MΩ 至 250 MΩ","cmc":"0,066 %"},{"name":"","range":"250 MΩ 至 300 MΩ","cmc":"0,056 %"},{"name":"","range":"300 MΩ 至 400 MΩ","cmc":"0,049 %"},{"name":"","range":"400 MΩ 至 500 MΩ","cmc":"0,041 %"},{"name":"","range":"500 MΩ 至 700 MΩ","cmc":"0,036 %"},{"name":"","range":"700 MΩ 至 1 GΩ","cmc":"0,030 %"},{"name":"","range":"1 GΩ 至 1,9 GΩ","cmc":"0,026 %"},{"name":"","range":"1,9 GΩ 至 2 GΩ","cmc":"0,021 %"},{"name":"","range":"2 GΩ 至 2,5 GΩ","cmc":"0,56 %"},{"name":"","range":"2,5 GΩ 至 3 GΩ","cmc":"0,46 %"},{"name":"","range":"3 GΩ 至 4 GΩ","cmc":"0,39 %"},{"name":"","range":"4 GΩ 至 5 GΩ","cmc":"0,31 %"},{"name":"","range":"5 GΩ 至 6 GΩ","cmc":"0,26 %"},{"name":"","range":"6 GΩ 至 7 GΩ","cmc":"0,23 %"},{"name":"","range":"7 GΩ 至 10 GΩ","cmc":"0,20 %"},{"name":"","range":"10 GΩ 至 15 GΩ","cmc":"0,16 %"},{"name":"","range":"15 GΩ 至 19 GΩ","cmc":"0,13 %"},{"name":"","range":"19 GΩ 至 20 GΩ","cmc":"0,11 %"}],"parameters_cs":[{"name":"","range":"0 Ω až 0,1 Ω","cmc":"6 µΩ"},{"name":"","range":"0,1 Ω až 0,5 Ω","cmc":"12 µΩ"},{"name":"","range":"0,5 Ω až 1 Ω","cmc":"20 µΩ"},{"name":"","range":"1 Ω až 2 Ω","cmc":"0,0020 %"},{"name":"","range":"2 Ω až 3 Ω","cmc":"0,0017 %"},{"name":"","range":"3 Ω až 5 Ω","cmc":"0,0014 %"},{"name":"","range":"5 Ω až 15 Ω","cmc":"0,0012 %"},{"name":"","range":"15 Ω až 19 Ω","cmc":"0,0010 %"},{"name":"","range":"19 Ω až 20 Ω","cmc":"0,00098 %"},{"name":"","range":"20 Ω až 25 Ω","cmc":"0,0011 %"},{"name":"","range":"25 Ω až 30 Ω","cmc":"0,00096 %"},{"name":"","range":"30 Ω až 50 Ω","cmc":"0,00092 %"},{"name":"","range":"50 Ω až 100 Ω","cmc":"0,00086 %"},{"name":"","range":"100 Ω až 190 Ω","cmc":"0,00081 %"},{"name":"","range":"190 Ω až 200 Ω","cmc":"0,00078 %"},{"name":"","range":"200 Ω až 250 Ω","cmc":"0,0011 %"},{"name":"","range":"250 Ω až 300 Ω","cmc":"0,00096 %"},{"name":"","range":"300 Ω až 500 Ω","cmc":"0,00092 %"},{"name":"","range":"500 Ω až 1 kΩ","cmc":"0,00086 %"},{"name":"","range":"1 kΩ až 1,9 kΩ","cmc":"0,00081 %"},{"name":"","range":"1,9 kΩ až 2 kΩ","cmc":"0,00078 %"},{"name":"","range":"2 kΩ až 2,5 kΩ","cmc":"0,0011 %"},{"name":"","range":"2,5 kΩ až 3 kΩ","cmc":"0,00096 %"},{"name":"","range":"3 kΩ až 5 kΩ","cmc":"0,00092 %"},{"name":"","range":"5 kΩ až 10 kΩ","cmc":"0,00086 %"},{"name":"","range":"10 kΩ až 19 kΩ","cmc":"0,00081 %"},{"name":"","range":"19 kΩ až 20 kΩ","cmc":"0,00078 %"},{"name":"","range":"20 kΩ až 25 kΩ","cmc":"0,0011 %"},{"name":"","range":"25 kΩ až 30 kΩ","cmc":"0,00096 %"},{"name":"","range":"30 kΩ až 50 kΩ","cmc":"0,00092 %"},{"name":"","range":"50 kΩ až 100 kΩ","cmc":"0,00086 %"},{"name":"","range":"100 kΩ až 190 kΩ","cmc":"0,00081 %"},{"name":"","range":"190 kΩ až 200 kΩ","cmc":"0,00078 %"},{"name":"","range":"200 kΩ až 300 kΩ","cmc":"0,0014 %"},{"name":"","range":"300 kΩ až 1 MΩ","cmc":"0,0012 %"},{"name":"","range":"1 MΩ až 1,9 MΩ","cmc":"0,00096 %"},{"name":"","range":"1,9 MΩ až 2 MΩ","cmc":"0,00091 %"},{"name":"","range":"2 MΩ až 5 MΩ","cmc":"0,0021 %"},{"name":"","range":"5 MΩ až 19 MΩ","cmc":"0,0018 %"},{"name":"","range":"19 MΩ až 20 MΩ","cmc":"0,0016 %"},{"name":"","range":"20 MΩ až 30 MΩ","cmc":"0,012 %"},{"name":"","range":"30 MΩ až 50 MΩ","cmc":"0,0094 %"},{"name":"","range":"50 MΩ až 100 MΩ","cmc":"0,0081 %"},{"name":"","range":"100 MΩ až 190 MΩ","cmc":"0,0071 %"},{"name":"","range":"190 MΩ až 200 MΩ","cmc":"0,0066 %"},{"name":"","range":"200 MΩ až 250 MΩ","cmc":"0,066 %"},{"name":"","range":"250 MΩ až 300 MΩ","cmc":"0,056 %"},{"name":"","range":"300 MΩ až 400 MΩ","cmc":"0,049 %"},{"name":"","range":"400 MΩ až 500 MΩ","cmc":"0,041 %"},{"name":"","range":"500 MΩ až 700 MΩ","cmc":"0,036 %"},{"name":"","range":"700 MΩ až 1 GΩ","cmc":"0,030 %"},{"name":"","range":"1 GΩ až 1,9 GΩ","cmc":"0,026 %"},{"name":"","range":"1,9 GΩ až 2 GΩ","cmc":"0,021 %"},{"name":"","range":"2 GΩ až 2,5 GΩ","cmc":"0,56 %"},{"name":"","range":"2,5 GΩ až 3 GΩ","cmc":"0,46 %"},{"name":"","range":"3 GΩ až 4 GΩ","cmc":"0,39 %"},{"name":"","range":"4 GΩ až 5 GΩ","cmc":"0,31 %"},{"name":"","range":"5 GΩ až 6 GΩ","cmc":"0,26 %"},{"name":"","range":"6 GΩ až 7 GΩ","cmc":"0,23 %"},{"name":"","range":"7 GΩ až 10 GΩ","cmc":"0,20 %"},{"name":"","range":"10 GΩ až 15 GΩ","cmc":"0,16 %"},{"name":"","range":"15 GΩ až 19 GΩ","cmc":"0,13 %"},{"name":"","range":"19 GΩ až 20 GΩ","cmc":"0,11 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 0,1 Ω CMC 6 µΩ\nod 0,1 Ω do 0,5 Ω CMC 12 µΩ\nod 0,5 Ω do 1 Ω CMC 20 µΩ\nod 1 Ω do 2 Ω CMC 0,0020 %\nod 2 Ω do 3 Ω CMC 0,0017 %\nod 3 Ω do 5 Ω CMC 0,0014 %\nod 5 Ω do 15 Ω CMC 0,0012 %\nod 15 Ω do 19 Ω CMC 0,0010 %\nod 19 Ω do 20 Ω CMC 0,00098 %\nod 20 Ω do 25 Ω CMC 0,0011 %\nod 25 Ω do 30 Ω CMC 0,00096 %\nod 30 Ω do 50 Ω CMC 0,00092 %\nod 50 Ω do 100 Ω CMC 0,00086 %\nod 100 Ω do 190 Ω CMC 0,00081 %\nod 190 Ω do 200 Ω CMC 0,00078 %\nod 200 Ω do 250 Ω CMC 0,0011 %\nod 250 Ω do 300 Ω CMC 0,00096 %\nod 300 Ω do 500 Ω CMC 0,00092 %\nod 500 Ω do 1 kΩ CMC 0,00086 %\nod 1 kΩ do 1,9 kΩ CMC 0,00081 %\nod 1,9 kΩ do 2 kΩ CMC 0,00078 %\nod 2 kΩ do 2,5 kΩ CMC 0,0011 %\nod 2,5 kΩ do 3 kΩ CMC 0,00096 %\nod 3 kΩ do 5 kΩ CMC 0,00092 %\nod 5 kΩ do 10 kΩ CMC 0,00086 %\nod 10 kΩ do 19 kΩ CMC 0,00081 %\nod 19 kΩ do 20 kΩ CMC 0,00078 %\nod 20 kΩ do 25 kΩ CMC 0,0011 %\nod 25 kΩ do 30 kΩ CMC 0,00096 %\nod 30 kΩ do 50 kΩ CMC 0,00092 %\nod 50 kΩ do 100 kΩ CMC 0,00086 %\nod 100 kΩ do 190 kΩ CMC 0,00081 %\nod 190 kΩ do 200 kΩ CMC 0,00078 %\nod 200 kΩ do 300 kΩ CMC 0,0014 %\nod 300 kΩ do 1 MΩ CMC 0,0012 %\nod 1 MΩ do 1,9 MΩ CMC 0,00096 %\nod 1,9 MΩ do 2 MΩ CMC 0,00091 %\nod 2 MΩ do 5 MΩ CMC 0,0021 %\nod 5 MΩ do 19 MΩ CMC 0,0018 %\nod 19 MΩ do 20 MΩ CMC 0,0016 %\nod 20 MΩ do 30 MΩ CMC 0,012 %\nod 30 MΩ do 50 MΩ CMC 0,0094 %\nod 50 MΩ do 100 MΩ CMC 0,0081 %\nod 100 MΩ do 190 MΩ CMC 0,0071 %\nod 190 MΩ do 200 MΩ CMC 0,0066 %\nod 200 MΩ do 250 MΩ CMC 0,066 %\nod 250 MΩ do 300 MΩ CMC 0,056 %\nod 300 MΩ do 400 MΩ CMC 0,049 %\nod 400 MΩ do 500 MΩ CMC 0,041 %\nod 500 MΩ do 700 MΩ CMC 0,036 %\nod 700 MΩ do 1 GΩ CMC 0,030 %\nod 1 GΩ do 1,9 GΩ CMC 0,026 %\nod 1,9 GΩ do 2 GΩ CMC 0,021 %\nod 2 GΩ do 2,5 GΩ CMC 0,56 %\nod 2,5 GΩ do 3 GΩ CMC 0,46 %\nod 3 GΩ do 4 GΩ CMC 0,39 %\nod 4 GΩ do 5 GΩ CMC 0,31 %\nod 5 GΩ do 6 GΩ CMC 0,26 %\nod 6 GΩ do 7 GΩ CMC 0,23 %\nod 7 GΩ do 10 GΩ CMC 0,20 %\nod 10 GΩ do 15 GΩ CMC 0,16 %\nod 15 GΩ do 19 GΩ CMC 0,13 %\nod 19 GΩ do 20 GΩ CMC 0,11 %\nPomiar bezpośredni multimetrem","reference":"TP5, TP21","norm_bases":["TP5","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / Wzorce rezystancji przy prądzie stałym Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 Ω do 0,1 Ω CMC 6 µΩ od 0,1 Ω do 0,5 Ω CMC 12 µΩ od 0,5 Ω do 1 Ω CMC 20 µΩ od 1 Ω do 2 Ω CMC 0,0020 % od 2 Ω do 3 Ω CMC 0,0017 % od 3 Ω do 5 Ω CMC 0,0014 % od 5 Ω do 15 Ω CMC 0,0012 % od 15 Ω do 19 Ω CMC 0,0010 % od 19 Ω do 20 Ω CMC 0,00098 % od 20 Ω do 25 Ω CMC 0,0011 % od 25 Ω do 30 Ω CMC 0,00096 % od 30 Ω do 50 Ω CMC 0,00092 % od 50 Ω do 100 Ω CMC 0,00086 % od 100 Ω do 190 Ω CMC 0,00081 % od 190 Ω do 200 Ω CMC 0,00078 % od 200 Ω do 250 Ω CMC 0,0011 % od 250 Ω do 300 Ω CMC 0,00096 % od 300 Ω do 500 Ω CMC 0,00092 % od 500 Ω do 1 kΩ CMC 0,00086 % od 1 kΩ do 1,9 kΩ CMC 0,00081 % od 1,9 kΩ do 2 kΩ CMC 0,00078 % od 2 kΩ do 2,5 kΩ CMC 0,0011 % od 2,5 kΩ do 3 kΩ CMC 0,00096 % od 3 kΩ do 5 kΩ CMC 0,00092 % od 5 kΩ do 10 kΩ CMC 0,00086 % od 10 kΩ do 19 kΩ CMC 0,00081 % od 19 kΩ do 20 kΩ CMC 0,00078 % od 20 kΩ do 25 kΩ CMC 0,0011 % od 25 kΩ do 30 kΩ CMC 0,00096 % od 30 kΩ do 50 kΩ CMC 0,00092 % od 50 kΩ do 100 kΩ CMC 0,00086 % od 100 kΩ do 190 kΩ CMC 0,00081 % od 190 kΩ do 200 kΩ CMC 0,00078 % od 200 kΩ do 300 kΩ CMC 0,0014 % od 300 kΩ do 1 MΩ CMC 0,0012 % od 1 MΩ do 1,9 MΩ CMC 0,00096 % od 1,9 MΩ do 2 MΩ CMC 0,00091 % od 2 MΩ do 5 MΩ CMC 0,0021 % od 5 MΩ do 19 MΩ CMC 0,0018 % od 19 MΩ do 20 MΩ CMC 0,0016 % od 20 MΩ do 30 MΩ CMC 0,012 % od 30 MΩ do 50 MΩ CMC 0,0094 % od 50 MΩ do 100 MΩ CMC 0,0081 % od 100 MΩ do 190 MΩ CMC 0,0071 % od 190 MΩ do 200 MΩ CMC 0,0066 % od 200 MΩ do 250 MΩ CMC 0,066 % od 250 MΩ do 300 MΩ CMC 0,056 % od 300 MΩ do 400 MΩ CMC 0,049 % od 400 MΩ do 500 MΩ CMC 0,041 % od 500 MΩ do 700 MΩ CMC 0,036 % od 700 MΩ do 1 GΩ CMC 0,030 % od 1 GΩ do 1,9 GΩ CMC 0,026 % od 1,9 GΩ do 2 GΩ CMC 0,021 % od 2 GΩ do 2,5 GΩ CMC 0,56 % od 2,5 GΩ do 3 GΩ CMC 0,46 % od 3 GΩ do 4 GΩ CMC 0,39 % od 4 GΩ do 5 GΩ CMC 0,31 % od 5 GΩ do 6 GΩ CMC 0,26 % od 6 GΩ do 7 GΩ CMC 0,23 % od 7 GΩ do 10 GΩ CMC 0,20 % od 10 GΩ do 15 GΩ CMC 0,16 % od 15 GΩ do 19 GΩ CMC 0,13 % od 19 GΩ do 20 GΩ CMC 0,11 % Stejnosměrný odpor / Etalony stejnosměrného elektrického odporu Kalibrace – elektrické veličiny Přímé měření multimetrem 0 Ω až 0,1 Ω CMC 6 µΩ 0,1 Ω až 0,5 Ω CMC 12 µΩ 0,5 Ω až 1 Ω CMC 20 µΩ 1 Ω až 2 Ω CMC 0,0020 % 2 Ω až 3 Ω CMC 0,0017 % 3 Ω až 5 Ω CMC 0,0014 % 5 Ω až 15 Ω CMC 0,0012 % 15 Ω až 19 Ω CMC 0,0010 % 19 Ω až 20 Ω CMC 0,00098 % 20 Ω až 25 Ω CMC 0,0011 % 25 Ω až 30 Ω CMC 0,00096 % 30 Ω až 50 Ω CMC 0,00092 % 50 Ω až 100 Ω CMC 0,00086 % 100 Ω až 190 Ω CMC 0,00081 % 190 Ω až 200 Ω CMC 0,00078 % 200 Ω až 250 Ω CMC 0,0011 % 250 Ω až 300 Ω CMC 0,00096 % 300 Ω až 500 Ω CMC 0,00092 % 500 Ω až 1 kΩ CMC 0,00086 % 1 kΩ až 1,9 kΩ CMC 0,00081 % 1,9 kΩ až 2 kΩ CMC 0,00078 % 2 kΩ až 2,5 kΩ CMC 0,0011 % 2,5 kΩ až 3 kΩ CMC 0,00096 % 3 kΩ až 5 kΩ CMC 0,00092 % 5 kΩ až 10 kΩ CMC 0,00086 % 10 kΩ až 19 kΩ CMC 0,00081 % 19 kΩ až 20 kΩ CMC 0,00078 % 20 kΩ až 25 kΩ CMC 0,0011 % 25 kΩ až 30 kΩ CMC 0,00096 % 30 kΩ až 50 kΩ CMC 0,00092 % 50 kΩ až 100 kΩ CMC 0,00086 % 100 kΩ až 190 kΩ CMC 0,00081 % 190 kΩ až 200 kΩ CMC 0,00078 % 200 kΩ až 300 kΩ CMC 0,0014 % 300 kΩ až 1 MΩ CMC 0,0012 % 1 MΩ až 1,9 MΩ CMC 0,00096 % 1,9 MΩ až 2 MΩ CMC 0,00091 % 2 MΩ až 5 MΩ CMC 0,0021 % 5 MΩ až 19 MΩ CMC 0,0018 % 19 MΩ až 20 MΩ CMC 0,0016 % 20 MΩ až 30 MΩ CMC 0,012 % 30 MΩ až 50 MΩ CMC 0,0094 % 50 MΩ až 100 MΩ CMC 0,0081 % 100 MΩ až 190 MΩ CMC 0,0071 % 190 MΩ až 200 MΩ CMC 0,0066 % 200 MΩ až 250 MΩ CMC 0,066 % 250 MΩ až 300 MΩ CMC 0,056 % 300 MΩ až 400 MΩ CMC 0,049 % 400 MΩ až 500 MΩ CMC 0,041 % 500 MΩ až 700 MΩ CMC 0,036 % 700 MΩ až 1 GΩ CMC 0,030 % 1 GΩ až 1,9 GΩ CMC 0,026 % 1,9 GΩ až 2 GΩ CMC 0,021 % 2 GΩ až 2,5 GΩ CMC 0,56 % 2,5 GΩ až 3 GΩ CMC 0,46 % 3 GΩ až 4 GΩ CMC 0,39 % 4 GΩ až 5 GΩ CMC 0,31 % 5 GΩ až 6 GΩ CMC 0,26 % 6 GΩ až 7 GΩ CMC 0,23 % 7 GΩ až 10 GΩ CMC 0,20 % 10 GΩ až 15 GΩ CMC 0,16 % 15 GΩ až 19 GΩ CMC 0,13 % 19 GΩ až 20 GΩ CMC 0,11 % TP5, TP21 Rezystancja przy pradzie stalym / Wzorce rezystancji przy pradzie stalym Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 Ω do 0,1 Ω CMC 6 µΩ od 0,1 Ω do 0,5 Ω CMC 12 µΩ od 0,5 Ω do 1 Ω CMC 20 µΩ od 1 Ω do 2 Ω CMC 0,0020 % od 2 Ω do 3 Ω CMC 0,0017 % od 3 Ω do 5 Ω CMC 0,0014 % od 5 Ω do 15 Ω CMC 0,0012 % od 15 Ω do 19 Ω CMC 0,0010 % od 19 Ω do 20 Ω CMC 0,00098 % od 20 Ω do 25 Ω CMC 0,0011 % od 25 Ω do 30 Ω CMC 0,00096 % od 30 Ω do 50 Ω CMC 0,00092 % od 50 Ω do 100 Ω CMC 0,00086 % od 100 Ω do 190 Ω CMC 0,00081 % od 190 Ω do 200 Ω CMC 0,00078 % od 200 Ω do 250 Ω CMC 0,0011 % od 250 Ω do 300 Ω CMC 0,00096 % od 300 Ω do 500 Ω CMC 0,00092 % od 500 Ω do 1 kΩ CMC 0,00086 % od 1 kΩ do 1,9 kΩ CMC 0,00081 % od 1,9 kΩ do 2 kΩ CMC 0,00078 % od 2 kΩ do 2,5 kΩ CMC 0,0011 % od 2,5 kΩ do 3 kΩ CMC 0,00096 % od 3 kΩ do 5 kΩ CMC 0,00092 % od 5 kΩ do 10 kΩ CMC 0,00086 % od 10 kΩ do 19 kΩ CMC 0,00081 % od 19 kΩ do 20 kΩ CMC 0,00078 % od 20 kΩ do 25 kΩ CMC 0,0011 % od 25 kΩ do 30 kΩ CMC 0,00096 % od 30 kΩ do 50 kΩ CMC 0,00092 % od 50 kΩ do 100 kΩ CMC 0,00086 % od 100 kΩ do 190 kΩ CMC 0,00081 % od 190 kΩ do 200 kΩ CMC 0,00078 % od 200 kΩ do 300 kΩ CMC 0,0014 % od 300 kΩ do 1 MΩ CMC 0,0012 % od 1 MΩ do 1,9 MΩ CMC 0,00096 % od 1,9 MΩ do 2 MΩ CMC 0,00091 % od 2 MΩ do 5 MΩ CMC 0,0021 % od 5 MΩ do 19 MΩ CMC 0,0018 % od 19 MΩ do 20 MΩ CMC 0,0016 % od 20 MΩ do 30 MΩ CMC 0,012 % od 30 MΩ do 50 MΩ CMC 0,0094 % od 50 MΩ do 100 MΩ CMC 0,0081 % od 100 MΩ do 190 MΩ CMC 0,0071 % od 190 MΩ do 200 MΩ CMC 0,0066 % od 200 MΩ do 250 MΩ CMC 0,066 % od 250 MΩ do 300 MΩ CMC 0,056 % od 300 MΩ do 400 MΩ CMC 0,049 % od 400 MΩ do 500 MΩ CMC 0,041 % od 500 MΩ do 700 MΩ CMC 0,036 % od 700 MΩ do 1 GΩ CMC 0,030 % od 1 GΩ do 1,9 GΩ CMC 0,026 % od 1,9 GΩ do 2 GΩ CMC 0,021 % od 2 GΩ do 2,5 GΩ CMC 0,56 % od 2,5 GΩ do 3 GΩ CMC 0,46 % od 3 GΩ do 4 GΩ CMC 0,39 % od 4 GΩ do 5 GΩ CMC 0,31 % od 5 GΩ do 6 GΩ CMC 0,26 % od 6 GΩ do 7 GΩ CMC 0,23 % od 7 GΩ do 10 GΩ CMC 0,20 % od 10 GΩ do 15 GΩ CMC 0,16 % od 15 GΩ do 19 GΩ CMC 0,13 % od 19 GΩ do 20 GΩ CMC 0,11 % Stejnosmerny odpor / Etalony stejnosmerneho elektrickeho odporu Kalibrace – elektricke veliciny Prime mereni multimetrem 0 Ω az 0,1 Ω CMC 6 µΩ 0,1 Ω az 0,5 Ω CMC 12 µΩ 0,5 Ω az 1 Ω CMC 20 µΩ 1 Ω az 2 Ω CMC 0,0020 % 2 Ω az 3 Ω CMC 0,0017 % 3 Ω az 5 Ω CMC 0,0014 % 5 Ω az 15 Ω CMC 0,0012 % 15 Ω az 19 Ω CMC 0,0010 % 19 Ω az 20 Ω CMC 0,00098 % 20 Ω az 25 Ω CMC 0,0011 % 25 Ω az 30 Ω CMC 0,00096 % 30 Ω az 50 Ω CMC 0,00092 % 50 Ω az 100 Ω CMC 0,00086 % 100 Ω az 190 Ω CMC 0,00081 % 190 Ω az 200 Ω CMC 0,00078 % 200 Ω az 250 Ω CMC 0,0011 % 250 Ω az 300 Ω CMC 0,00096 % 300 Ω az 500 Ω CMC 0,00092 % 500 Ω az 1 kΩ CMC 0,00086 % 1 kΩ az 1,9 kΩ CMC 0,00081 % 1,9 kΩ az 2 kΩ CMC 0,00078 % 2 kΩ az 2,5 kΩ CMC 0,0011 % 2,5 kΩ az 3 kΩ CMC 0,00096 % 3 kΩ az 5 kΩ CMC 0,00092 % 5 kΩ az 10 kΩ CMC 0,00086 % 10 kΩ az 19 kΩ CMC 0,00081 % 19 kΩ az 20 kΩ CMC 0,00078 % 20 kΩ az 25 kΩ CMC 0,0011 % 25 kΩ az 30 kΩ CMC 0,00096 % 30 kΩ az 50 kΩ CMC 0,00092 % 50 kΩ az 100 kΩ CMC 0,00086 % 100 kΩ az 190 kΩ CMC 0,00081 % 190 kΩ az 200 kΩ CMC 0,00078 % 200 kΩ az 300 kΩ CMC 0,0014 % 300 kΩ az 1 MΩ CMC 0,0012 % 1 MΩ az 1,9 MΩ CMC 0,00096 % 1,9 MΩ az 2 MΩ CMC 0,00091 % 2 MΩ az 5 MΩ CMC 0,0021 % 5 MΩ az 19 MΩ CMC 0,0018 % 19 MΩ az 20 MΩ CMC 0,0016 % 20 MΩ az 30 MΩ CMC 0,012 % 30 MΩ az 50 MΩ CMC 0,0094 % 50 MΩ az 100 MΩ CMC 0,0081 % 100 MΩ az 190 MΩ CMC 0,0071 % 190 MΩ az 200 MΩ CMC 0,0066 % 200 MΩ az 250 MΩ CMC 0,066 % 250 MΩ az 300 MΩ CMC 0,056 % 300 MΩ az 400 MΩ CMC 0,049 % 400 MΩ az 500 MΩ CMC 0,041 % 500 MΩ az 700 MΩ CMC 0,036 % 700 MΩ az 1 GΩ CMC 0,030 % 1 GΩ az 1,9 GΩ CMC 0,026 % 1,9 GΩ az 2 GΩ CMC 0,021 % 2 GΩ az 2,5 GΩ CMC 0,56 % 2,5 GΩ az 3 GΩ CMC 0,46 % 3 GΩ az 4 GΩ CMC 0,39 % 4 GΩ az 5 GΩ CMC 0,31 % 5 GΩ az 6 GΩ CMC 0,26 % 6 GΩ az 7 GΩ CMC 0,23 % 7 GΩ az 10 GΩ CMC 0,20 % 10 GΩ az 15 GΩ CMC 0,16 % 15 GΩ az 19 GΩ CMC 0,13 % 19 GΩ az 20 GΩ CMC 0,11 % TP5, TP21","search_en":"DC resistance / DC resistance standards Calibration – electrical quantities Direct measurement using a multimeter 0 Ω to 0,1 Ω CMC 6 µΩ 0,1 Ω to 0,5 Ω CMC 12 µΩ 0,5 Ω to 1 Ω CMC 20 µΩ 1 Ω to 2 Ω CMC 0,0020 % 2 Ω to 3 Ω CMC 0,0017 % 3 Ω to 5 Ω CMC 0,0014 % 5 Ω to 15 Ω CMC 0,0012 % 15 Ω to 19 Ω CMC 0,0010 % 19 Ω to 20 Ω CMC 0,00098 % 20 Ω to 25 Ω CMC 0,0011 % 25 Ω to 30 Ω CMC 0,00096 % 30 Ω to 50 Ω CMC 0,00092 % 50 Ω to 100 Ω CMC 0,00086 % 100 Ω to 190 Ω CMC 0,00081 % 190 Ω to 200 Ω CMC 0,00078 % 200 Ω to 250 Ω CMC 0,0011 % 250 Ω to 300 Ω CMC 0,00096 % 300 Ω to 500 Ω CMC 0,00092 % 500 Ω to 1 kΩ CMC 0,00086 % 1 kΩ to 1,9 kΩ CMC 0,00081 % 1,9 kΩ to 2 kΩ CMC 0,00078 % 2 kΩ to 2,5 kΩ CMC 0,0011 % 2,5 kΩ to 3 kΩ CMC 0,00096 % 3 kΩ to 5 kΩ CMC 0,00092 % 5 kΩ to 10 kΩ CMC 0,00086 % 10 kΩ to 19 kΩ CMC 0,00081 % 19 kΩ to 20 kΩ CMC 0,00078 % 20 kΩ to 25 kΩ CMC 0,0011 % 25 kΩ to 30 kΩ CMC 0,00096 % 30 kΩ to 50 kΩ CMC 0,00092 % 50 kΩ to 100 kΩ CMC 0,00086 % 100 kΩ to 190 kΩ CMC 0,00081 % 190 kΩ to 200 kΩ CMC 0,00078 % 200 kΩ to 300 kΩ CMC 0,0014 % 300 kΩ to 1 MΩ CMC 0,0012 % 1 MΩ to 1,9 MΩ CMC 0,00096 % 1,9 MΩ to 2 MΩ CMC 0,00091 % 2 MΩ to 5 MΩ CMC 0,0021 % 5 MΩ to 19 MΩ CMC 0,0018 % 19 MΩ to 20 MΩ CMC 0,0016 % 20 MΩ to 30 MΩ CMC 0,012 % 30 MΩ to 50 MΩ CMC 0,0094 % 50 MΩ to 100 MΩ CMC 0,0081 % 100 MΩ to 190 MΩ CMC 0,0071 % 190 MΩ to 200 MΩ CMC 0,0066 % 200 MΩ to 250 MΩ CMC 0,066 % 250 MΩ to 300 MΩ CMC 0,056 % 300 MΩ to 400 MΩ CMC 0,049 % 400 MΩ to 500 MΩ CMC 0,041 % 500 MΩ to 700 MΩ CMC 0,036 % 700 MΩ to 1 GΩ CMC 0,030 % 1 GΩ to 1,9 GΩ CMC 0,026 % 1,9 GΩ to 2 GΩ CMC 0,021 % 2 GΩ to 2,5 GΩ CMC 0,56 % 2,5 GΩ to 3 GΩ CMC 0,46 % 3 GΩ to 4 GΩ CMC 0,39 % 4 GΩ to 5 GΩ CMC 0,31 % 5 GΩ to 6 GΩ CMC 0,26 % 6 GΩ to 7 GΩ CMC 0,23 % 7 GΩ to 10 GΩ CMC 0,20 % 10 GΩ to 15 GΩ CMC 0,16 % 15 GΩ to 19 GΩ CMC 0,13 % 19 GΩ to 20 GΩ CMC 0,11 % TP5, TP21","search_zh":"直流电阻 / 直流电阻标准器 校准 – 电学量 用万用表直接测量 0 Ω 至 0,1 Ω CMC 6 µΩ 0,1 Ω 至 0,5 Ω CMC 12 µΩ 0,5 Ω 至 1 Ω CMC 20 µΩ 1 Ω 至 2 Ω CMC 0,0020 % 2 Ω 至 3 Ω CMC 0,0017 % 3 Ω 至 5 Ω CMC 0,0014 % 5 Ω 至 15 Ω CMC 0,0012 % 15 Ω 至 19 Ω CMC 0,0010 % 19 Ω 至 20 Ω CMC 0,00098 % 20 Ω 至 25 Ω CMC 0,0011 % 25 Ω 至 30 Ω CMC 0,00096 % 30 Ω 至 50 Ω CMC 0,00092 % 50 Ω 至 100 Ω CMC 0,00086 % 100 Ω 至 190 Ω CMC 0,00081 % 190 Ω 至 200 Ω CMC 0,00078 % 200 Ω 至 250 Ω CMC 0,0011 % 250 Ω 至 300 Ω CMC 0,00096 % 300 Ω 至 500 Ω CMC 0,00092 % 500 Ω 至 1 kΩ CMC 0,00086 % 1 kΩ 至 1,9 kΩ CMC 0,00081 % 1,9 kΩ 至 2 kΩ CMC 0,00078 % 2 kΩ 至 2,5 kΩ CMC 0,0011 % 2,5 kΩ 至 3 kΩ CMC 0,00096 % 3 kΩ 至 5 kΩ CMC 0,00092 % 5 kΩ 至 10 kΩ CMC 0,00086 % 10 kΩ 至 19 kΩ CMC 0,00081 % 19 kΩ 至 20 kΩ CMC 0,00078 % 20 kΩ 至 25 kΩ CMC 0,0011 % 25 kΩ 至 30 kΩ CMC 0,00096 % 30 kΩ 至 50 kΩ CMC 0,00092 % 50 kΩ 至 100 kΩ CMC 0,00086 % 100 kΩ 至 190 kΩ CMC 0,00081 % 190 kΩ 至 200 kΩ CMC 0,00078 % 200 kΩ 至 300 kΩ CMC 0,0014 % 300 kΩ 至 1 MΩ CMC 0,0012 % 1 MΩ 至 1,9 MΩ CMC 0,00096 % 1,9 MΩ 至 2 MΩ CMC 0,00091 % 2 MΩ 至 5 MΩ CMC 0,0021 % 5 MΩ 至 19 MΩ CMC 0,0018 % 19 MΩ 至 20 MΩ CMC 0,0016 % 20 MΩ 至 30 MΩ CMC 0,012 % 30 MΩ 至 50 MΩ CMC 0,0094 % 50 MΩ 至 100 MΩ CMC 0,0081 % 100 MΩ 至 190 MΩ CMC 0,0071 % 190 MΩ 至 200 MΩ CMC 0,0066 % 200 MΩ 至 250 MΩ CMC 0,066 % 250 MΩ 至 300 MΩ CMC 0,056 % 300 MΩ 至 400 MΩ CMC 0,049 % 400 MΩ 至 500 MΩ CMC 0,041 % 500 MΩ 至 700 MΩ CMC 0,036 % 700 MΩ 至 1 GΩ CMC 0,030 % 1 GΩ 至 1,9 GΩ CMC 0,026 % 1,9 GΩ 至 2 GΩ CMC 0,021 % 2 GΩ 至 2,5 GΩ CMC 0,56 % 2,5 GΩ 至 3 GΩ CMC 0,46 % 3 GΩ 至 4 GΩ CMC 0,39 % 4 GΩ 至 5 GΩ CMC 0,31 % 5 GΩ 至 6 GΩ CMC 0,26 % 6 GΩ 至 7 GΩ CMC 0,23 % 7 GΩ 至 10 GΩ CMC 0,20 % 10 GΩ 至 15 GΩ CMC 0,16 % 15 GΩ 至 19 GΩ CMC 0,13 % 19 GΩ 至 20 GΩ CMC 0,11 % TP5, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c969de93e5775db54668676b","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja przy prądzie stałym / Mierniki rezystancji przy prądzie stałym","test_object_en":"DC resistance / DC resistance meters","test_object_zh":"直流电阻 / 直流电阻测量仪器","test_object_cs":"Stejnosměrný odpor / Měřidla stejnosměrného elektrického odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0,1 mΩ","cmc":"0,005 %"},{"name":"","range":"1 mΩ","cmc":"0,005 %"},{"name":"","range":"10 mΩ","cmc":"0,002 %"},{"name":"","range":"100 mΩ","cmc":"0,001 %"},{"name":"","range":"1 Ω","cmc":"0,0005 %"},{"name":"","range":"1,9 Ω","cmc":"0,02 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"19 Ω","cmc":"0,004 %"},{"name":"","range":"100 Ω","cmc":"0,0007 %"},{"name":"","range":"190 Ω","cmc":"0,003 %"},{"name":"","range":"1 kΩ","cmc":"0,0004 %"},{"name":"","range":"1,9 kΩ","cmc":"0,002 %"},{"name":"","range":"10 kΩ","cmc":"0,0004 %"},{"name":"","range":"19 kΩ","cmc":"0,002 %"},{"name":"","range":"100 kΩ","cmc":"0,0006 %"},{"name":"","range":"190 kΩ","cmc":"0,003 %"},{"name":"","range":"1 MΩ","cmc":"0,004 %"},{"name":"","range":"1,9 MΩ","cmc":"0,004 %"},{"name":"","range":"10 MΩ","cmc":"0,006 %"},{"name":"","range":"19 MΩ","cmc":"0,008 %"},{"name":"","range":"100 MΩ","cmc":"0,006 %"},{"name":"","range":"1 GΩ","cmc":"0,014 %"},{"name":"","range":"10 GΩ","cmc":"0,23 %"},{"name":"","range":"100 GΩ","cmc":"0,80 %"},{"name":"","range":"200 GΩ","cmc":"1,0 %"},{"name":"","range":"od 0 Ω do 1 Ω","cmc":"1,5 mΩ"},{"name":"","range":"od 1 Ω do 5 Ω","cmc":"0,13 %"},{"name":"","range":"od 5 Ω do 10 Ω","cmc":"0,021 %"},{"name":"","range":"od 10 Ω do 11 Ω","cmc":"0,026 %"},{"name":"","range":"od 11 Ω do 20 Ω","cmc":"0,030 %"},{"name":"","range":"od 20 Ω do 33 Ω","cmc":"0,023 %"},{"name":"","range":"od 33 Ω do 330 Ω","cmc":"0,016 %"},{"name":"","range":"od 330 Ω do 1,1 kΩ","cmc":"0,012 %"},{"name":"","range":"od 1,1 kΩ do 3,3 kΩ","cmc":"0,013 %"},{"name":"","range":"od 3,3 kΩ do 11 kΩ","cmc":"0,012 %"},{"name":"","range":"od 11 kΩ do 33 kΩ","cmc":"0,013 %"},{"name":"","range":"od 33 kΩ do 110 kΩ","cmc":"0,014 %"},{"name":"","range":"od 110 kΩ do 330 kΩ","cmc":"0,016 %"},{"name":"","range":"od 330 kΩ do 1,1 MΩ","cmc":"0,019 %"},{"name":"","range":"od 1,1 MΩ do 3,3 MΩ","cmc":"0,021 %"},{"name":"","range":"od 3,3 MΩ do 11 MΩ","cmc":"0,072 %"},{"name":"","range":"od 11 MΩ do 33 MΩ","cmc":"0,15 %"},{"name":"","range":"od 33 MΩ do 110 MΩ","cmc":"0,59 %"},{"name":"","range":"od 110 MΩ do 330 MΩ","cmc":"0,69 %"},{"name":"","range":"od 330 MΩ do 1,1 GΩ","cmc":"2,0 %"}],"parameters_en":[{"name":"","range":"0,1 mΩ","cmc":"0,005 %"},{"name":"","range":"1 mΩ","cmc":"0,005 %"},{"name":"","range":"10 mΩ","cmc":"0,002 %"},{"name":"","range":"100 mΩ","cmc":"0,001 %"},{"name":"","range":"1 Ω","cmc":"0,0005 %"},{"name":"","range":"1,9 Ω","cmc":"0,02 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"19 Ω","cmc":"0,004 %"},{"name":"","range":"100 Ω","cmc":"0,0007 %"},{"name":"","range":"190 Ω","cmc":"0,003 %"},{"name":"","range":"1 kΩ","cmc":"0,0004 %"},{"name":"","range":"1,9 kΩ","cmc":"0,002 %"},{"name":"","range":"10 kΩ","cmc":"0,0004 %"},{"name":"","range":"19 kΩ","cmc":"0,002 %"},{"name":"","range":"100 kΩ","cmc":"0,0006 %"},{"name":"","range":"190 kΩ","cmc":"0,003 %"},{"name":"","range":"1 MΩ","cmc":"0,004 %"},{"name":"","range":"1,9 MΩ","cmc":"0,004 %"},{"name":"","range":"10 MΩ","cmc":"0,006 %"},{"name":"","range":"19 MΩ","cmc":"0,008 %"},{"name":"","range":"100 MΩ","cmc":"0,006 %"},{"name":"","range":"1 GΩ","cmc":"0,014 %"},{"name":"","range":"10 GΩ","cmc":"0,23 %"},{"name":"","range":"100 GΩ","cmc":"0,80 %"},{"name":"","range":"200 GΩ","cmc":"1,0 %"},{"name":"","range":"0 Ω to 1 Ω","cmc":"1,5 mΩ"},{"name":"","range":"1 Ω to 5 Ω","cmc":"0,13 %"},{"name":"","range":"5 Ω to 10 Ω","cmc":"0,021 %"},{"name":"","range":"10 Ω to 11 Ω","cmc":"0,026 %"},{"name":"","range":"11 Ω to 20 Ω","cmc":"0,030 %"},{"name":"","range":"20 Ω to 33 Ω","cmc":"0,023 %"},{"name":"","range":"33 Ω to 330 Ω","cmc":"0,016 %"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"0,012 %"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"0,013 %"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"0,012 %"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"0,013 %"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"0,014 %"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"0,016 %"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"0,019 %"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"0,021 %"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,072 %"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,15 %"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,59 %"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"0,69 %"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"2,0 %"}],"parameters_zh":[{"name":"","range":"0,1 mΩ","cmc":"0,005 %"},{"name":"","range":"1 mΩ","cmc":"0,005 %"},{"name":"","range":"10 mΩ","cmc":"0,002 %"},{"name":"","range":"100 mΩ","cmc":"0,001 %"},{"name":"","range":"1 Ω","cmc":"0,0005 %"},{"name":"","range":"1,9 Ω","cmc":"0,02 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"19 Ω","cmc":"0,004 %"},{"name":"","range":"100 Ω","cmc":"0,0007 %"},{"name":"","range":"190 Ω","cmc":"0,003 %"},{"name":"","range":"1 kΩ","cmc":"0,0004 %"},{"name":"","range":"1,9 kΩ","cmc":"0,002 %"},{"name":"","range":"10 kΩ","cmc":"0,0004 %"},{"name":"","range":"19 kΩ","cmc":"0,002 %"},{"name":"","range":"100 kΩ","cmc":"0,0006 %"},{"name":"","range":"190 kΩ","cmc":"0,003 %"},{"name":"","range":"1 MΩ","cmc":"0,004 %"},{"name":"","range":"1,9 MΩ","cmc":"0,004 %"},{"name":"","range":"10 MΩ","cmc":"0,006 %"},{"name":"","range":"19 MΩ","cmc":"0,008 %"},{"name":"","range":"100 MΩ","cmc":"0,006 %"},{"name":"","range":"1 GΩ","cmc":"0,014 %"},{"name":"","range":"10 GΩ","cmc":"0,23 %"},{"name":"","range":"100 GΩ","cmc":"0,80 %"},{"name":"","range":"200 GΩ","cmc":"1,0 %"},{"name":"","range":"0 Ω 至 1 Ω","cmc":"1,5 mΩ"},{"name":"","range":"1 Ω 至 5 Ω","cmc":"0,13 %"},{"name":"","range":"5 Ω 至 10 Ω","cmc":"0,021 %"},{"name":"","range":"10 Ω 至 11 Ω","cmc":"0,026 %"},{"name":"","range":"11 Ω 至 20 Ω","cmc":"0,030 %"},{"name":"","range":"20 Ω 至 33 Ω","cmc":"0,023 %"},{"name":"","range":"33 Ω 至 330 Ω","cmc":"0,016 %"},{"name":"","range":"330 Ω 至 1,1 kΩ","cmc":"0,012 %"},{"name":"","range":"1,1 kΩ 至 3,3 kΩ","cmc":"0,013 %"},{"name":"","range":"3,3 kΩ 至 11 kΩ","cmc":"0,012 %"},{"name":"","range":"11 kΩ 至 33 kΩ","cmc":"0,013 %"},{"name":"","range":"33 kΩ 至 110 kΩ","cmc":"0,014 %"},{"name":"","range":"110 kΩ 至 330 kΩ","cmc":"0,016 %"},{"name":"","range":"330 kΩ 至 1,1 MΩ","cmc":"0,019 %"},{"name":"","range":"1,1 MΩ 至 3,3 MΩ","cmc":"0,021 %"},{"name":"","range":"3,3 MΩ 至 11 MΩ","cmc":"0,072 %"},{"name":"","range":"11 MΩ 至 33 MΩ","cmc":"0,15 %"},{"name":"","range":"33 MΩ 至 110 MΩ","cmc":"0,59 %"},{"name":"","range":"110 MΩ 至 330 MΩ","cmc":"0,69 %"},{"name":"","range":"330 MΩ 至 1,1 GΩ","cmc":"2,0 %"}],"parameters_cs":[{"name":"","range":"0,1 mΩ","cmc":"0,005 %"},{"name":"","range":"1 mΩ","cmc":"0,005 %"},{"name":"","range":"10 mΩ","cmc":"0,002 %"},{"name":"","range":"100 mΩ","cmc":"0,001 %"},{"name":"","range":"1 Ω","cmc":"0,0005 %"},{"name":"","range":"1,9 Ω","cmc":"0,02 %"},{"name":"","range":"10 Ω","cmc":"0,0005 %"},{"name":"","range":"19 Ω","cmc":"0,004 %"},{"name":"","range":"100 Ω","cmc":"0,0007 %"},{"name":"","range":"190 Ω","cmc":"0,003 %"},{"name":"","range":"1 kΩ","cmc":"0,0004 %"},{"name":"","range":"1,9 kΩ","cmc":"0,002 %"},{"name":"","range":"10 kΩ","cmc":"0,0004 %"},{"name":"","range":"19 kΩ","cmc":"0,002 %"},{"name":"","range":"100 kΩ","cmc":"0,0006 %"},{"name":"","range":"190 kΩ","cmc":"0,003 %"},{"name":"","range":"1 MΩ","cmc":"0,004 %"},{"name":"","range":"1,9 MΩ","cmc":"0,004 %"},{"name":"","range":"10 MΩ","cmc":"0,006 %"},{"name":"","range":"19 MΩ","cmc":"0,008 %"},{"name":"","range":"100 MΩ","cmc":"0,006 %"},{"name":"","range":"1 GΩ","cmc":"0,014 %"},{"name":"","range":"10 GΩ","cmc":"0,23 %"},{"name":"","range":"100 GΩ","cmc":"0,80 %"},{"name":"","range":"200 GΩ","cmc":"1,0 %"},{"name":"","range":"0 Ω až 1 Ω","cmc":"1,5 mΩ"},{"name":"","range":"1 Ω až 5 Ω","cmc":"0,13 %"},{"name":"","range":"5 Ω až 10 Ω","cmc":"0,021 %"},{"name":"","range":"10 Ω až 11 Ω","cmc":"0,026 %"},{"name":"","range":"11 Ω až 20 Ω","cmc":"0,030 %"},{"name":"","range":"20 Ω až 33 Ω","cmc":"0,023 %"},{"name":"","range":"33 Ω až 330 Ω","cmc":"0,016 %"},{"name":"","range":"330 Ω až 1,1 kΩ","cmc":"0,012 %"},{"name":"","range":"1,1 kΩ až 3,3 kΩ","cmc":"0,013 %"},{"name":"","range":"3,3 kΩ až 11 kΩ","cmc":"0,012 %"},{"name":"","range":"11 kΩ až 33 kΩ","cmc":"0,013 %"},{"name":"","range":"33 kΩ až 110 kΩ","cmc":"0,014 %"},{"name":"","range":"110 kΩ až 330 kΩ","cmc":"0,016 %"},{"name":"","range":"330 kΩ až 1,1 MΩ","cmc":"0,019 %"},{"name":"","range":"1,1 MΩ až 3,3 MΩ","cmc":"0,021 %"},{"name":"","range":"3,3 MΩ až 11 MΩ","cmc":"0,072 %"},{"name":"","range":"11 MΩ až 33 MΩ","cmc":"0,15 %"},{"name":"","range":"33 MΩ až 110 MΩ","cmc":"0,59 %"},{"name":"","range":"110 MΩ až 330 MΩ","cmc":"0,69 %"},{"name":"","range":"330 MΩ až 1,1 GΩ","cmc":"2,0 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 mΩ CMC 0,005 %\n1 mΩ CMC 0,005 %\n10 mΩ CMC 0,002 %\n100 mΩ CMC 0,001 %\n1 Ω CMC 0,0005 %\n1,9 Ω CMC 0,02 %\n10 Ω CMC 0,0005 %\n19 Ω CMC 0,004 %\n100 Ω CMC 0,0007 %\n190 Ω CMC 0,003 %\n1 kΩ CMC 0,0004 %\n1,9 kΩ CMC 0,002 %\n10 kΩ CMC 0,0004 %\n19 kΩ CMC 0,002 %\n100 kΩ CMC 0,0006 %\n190 kΩ CMC 0,003 %\n1 MΩ CMC 0,004 %\n1,9 MΩ CMC 0,004 %\n10 MΩ CMC 0,006 %\n19 MΩ CMC 0,008 %\n100 MΩ CMC 0,006 %\n1 GΩ CMC 0,014 %\n10 GΩ CMC 0,23 %\n100 GΩ CMC 0,80 %\n200 GΩ CMC 1,0 %\nod 0 Ω do 1 Ω CMC 1,5 mΩ\nod 1 Ω do 5 Ω CMC 0,13 %\nod 5 Ω do 10 Ω CMC 0,021 %\nod 10 Ω do 11 Ω CMC 0,026 %\nod 11 Ω do 20 Ω CMC 0,030 %\nod 20 Ω do 33 Ω CMC 0,023 %\nod 33 Ω do 330 Ω CMC 0,016 %\nod 330 Ω do 1,1 kΩ CMC 0,012 %\nod 1,1 kΩ do 3,3 kΩ CMC 0,013 %\nod 3,3 kΩ do 11 kΩ CMC 0,012 %\nod 11 kΩ do 33 kΩ CMC 0,013 %\nod 33 kΩ do 110 kΩ CMC 0,014 %\nod 110 kΩ do 330 kΩ CMC 0,016 %\nod 330 kΩ do 1,1 MΩ CMC 0,019 %\nod 1,1 MΩ do 3,3 MΩ CMC 0,021 %\nod 3,3 MΩ do 11 MΩ CMC 0,072 %\nod 11 MΩ do 33 MΩ CMC 0,15 %\nod 33 MΩ do 110 MΩ CMC 0,59 %\nod 110 MΩ do 330 MΩ CMC 0,69 %\nod 330 MΩ do 1,1 GΩ CMC 2,0 %\nBezpośrednie generowanie kalibratorem","reference":"TP5, TP21","norm_bases":["TP5","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / Mierniki rezystancji przy prądzie stałym Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 0,1 mΩ CMC 0,005 % 1 mΩ CMC 0,005 % 10 mΩ CMC 0,002 % 100 mΩ CMC 0,001 % 1 Ω CMC 0,0005 % 1,9 Ω CMC 0,02 % 10 Ω CMC 0,0005 % 19 Ω CMC 0,004 % 100 Ω CMC 0,0007 % 190 Ω CMC 0,003 % 1 kΩ CMC 0,0004 % 1,9 kΩ CMC 0,002 % 10 kΩ CMC 0,0004 % 19 kΩ CMC 0,002 % 100 kΩ CMC 0,0006 % 190 kΩ CMC 0,003 % 1 MΩ CMC 0,004 % 1,9 MΩ CMC 0,004 % 10 MΩ CMC 0,006 % 19 MΩ CMC 0,008 % 100 MΩ CMC 0,006 % 1 GΩ CMC 0,014 % 10 GΩ CMC 0,23 % 100 GΩ CMC 0,80 % 200 GΩ CMC 1,0 % od 0 Ω do 1 Ω CMC 1,5 mΩ od 1 Ω do 5 Ω CMC 0,13 % od 5 Ω do 10 Ω CMC 0,021 % od 10 Ω do 11 Ω CMC 0,026 % od 11 Ω do 20 Ω CMC 0,030 % od 20 Ω do 33 Ω CMC 0,023 % od 33 Ω do 330 Ω CMC 0,016 % od 330 Ω do 1,1 kΩ CMC 0,012 % od 1,1 kΩ do 3,3 kΩ CMC 0,013 % od 3,3 kΩ do 11 kΩ CMC 0,012 % od 11 kΩ do 33 kΩ CMC 0,013 % od 33 kΩ do 110 kΩ CMC 0,014 % od 110 kΩ do 330 kΩ CMC 0,016 % od 330 kΩ do 1,1 MΩ CMC 0,019 % od 1,1 MΩ do 3,3 MΩ CMC 0,021 % od 3,3 MΩ do 11 MΩ CMC 0,072 % od 11 MΩ do 33 MΩ CMC 0,15 % od 33 MΩ do 110 MΩ CMC 0,59 % od 110 MΩ do 330 MΩ CMC 0,69 % od 330 MΩ do 1,1 GΩ CMC 2,0 % Stejnosměrný odpor / Měřidla stejnosměrného elektrického odporu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0,1 mΩ CMC 0,005 % 1 mΩ CMC 0,005 % 10 mΩ CMC 0,002 % 100 mΩ CMC 0,001 % 1 Ω CMC 0,0005 % 1,9 Ω CMC 0,02 % 10 Ω CMC 0,0005 % 19 Ω CMC 0,004 % 100 Ω CMC 0,0007 % 190 Ω CMC 0,003 % 1 kΩ CMC 0,0004 % 1,9 kΩ CMC 0,002 % 10 kΩ CMC 0,0004 % 19 kΩ CMC 0,002 % 100 kΩ CMC 0,0006 % 190 kΩ CMC 0,003 % 1 MΩ CMC 0,004 % 1,9 MΩ CMC 0,004 % 10 MΩ CMC 0,006 % 19 MΩ CMC 0,008 % 100 MΩ CMC 0,006 % 1 GΩ CMC 0,014 % 10 GΩ CMC 0,23 % 100 GΩ CMC 0,80 % 200 GΩ CMC 1,0 % 0 Ω až 1 Ω CMC 1,5 mΩ 1 Ω až 5 Ω CMC 0,13 % 5 Ω až 10 Ω CMC 0,021 % 10 Ω až 11 Ω CMC 0,026 % 11 Ω až 20 Ω CMC 0,030 % 20 Ω až 33 Ω CMC 0,023 % 33 Ω až 330 Ω CMC 0,016 % 330 Ω až 1,1 kΩ CMC 0,012 % 1,1 kΩ až 3,3 kΩ CMC 0,013 % 3,3 kΩ až 11 kΩ CMC 0,012 % 11 kΩ až 33 kΩ CMC 0,013 % 33 kΩ až 110 kΩ CMC 0,014 % 110 kΩ až 330 kΩ CMC 0,016 % 330 kΩ až 1,1 MΩ CMC 0,019 % 1,1 MΩ až 3,3 MΩ CMC 0,021 % 3,3 MΩ až 11 MΩ CMC 0,072 % 11 MΩ až 33 MΩ CMC 0,15 % 33 MΩ až 110 MΩ CMC 0,59 % 110 MΩ až 330 MΩ CMC 0,69 % 330 MΩ až 1,1 GΩ CMC 2,0 % TP5, TP21 Rezystancja przy pradzie stalym / Mierniki rezystancji przy pradzie stalym Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 0,1 mΩ CMC 0,005 % 1 mΩ CMC 0,005 % 10 mΩ CMC 0,002 % 100 mΩ CMC 0,001 % 1 Ω CMC 0,0005 % 1,9 Ω CMC 0,02 % 10 Ω CMC 0,0005 % 19 Ω CMC 0,004 % 100 Ω CMC 0,0007 % 190 Ω CMC 0,003 % 1 kΩ CMC 0,0004 % 1,9 kΩ CMC 0,002 % 10 kΩ CMC 0,0004 % 19 kΩ CMC 0,002 % 100 kΩ CMC 0,0006 % 190 kΩ CMC 0,003 % 1 MΩ CMC 0,004 % 1,9 MΩ CMC 0,004 % 10 MΩ CMC 0,006 % 19 MΩ CMC 0,008 % 100 MΩ CMC 0,006 % 1 GΩ CMC 0,014 % 10 GΩ CMC 0,23 % 100 GΩ CMC 0,80 % 200 GΩ CMC 1,0 % od 0 Ω do 1 Ω CMC 1,5 mΩ od 1 Ω do 5 Ω CMC 0,13 % od 5 Ω do 10 Ω CMC 0,021 % od 10 Ω do 11 Ω CMC 0,026 % od 11 Ω do 20 Ω CMC 0,030 % od 20 Ω do 33 Ω CMC 0,023 % od 33 Ω do 330 Ω CMC 0,016 % od 330 Ω do 1,1 kΩ CMC 0,012 % od 1,1 kΩ do 3,3 kΩ CMC 0,013 % od 3,3 kΩ do 11 kΩ CMC 0,012 % od 11 kΩ do 33 kΩ CMC 0,013 % od 33 kΩ do 110 kΩ CMC 0,014 % od 110 kΩ do 330 kΩ CMC 0,016 % od 330 kΩ do 1,1 MΩ CMC 0,019 % od 1,1 MΩ do 3,3 MΩ CMC 0,021 % od 3,3 MΩ do 11 MΩ CMC 0,072 % od 11 MΩ do 33 MΩ CMC 0,15 % od 33 MΩ do 110 MΩ CMC 0,59 % od 110 MΩ do 330 MΩ CMC 0,69 % od 330 MΩ do 1,1 GΩ CMC 2,0 % Stejnosmerny odpor / Meridla stejnosmerneho elektrickeho odporu Kalibrace – elektricke veliciny Prime generovani kalibratorem 0,1 mΩ CMC 0,005 % 1 mΩ CMC 0,005 % 10 mΩ CMC 0,002 % 100 mΩ CMC 0,001 % 1 Ω CMC 0,0005 % 1,9 Ω CMC 0,02 % 10 Ω CMC 0,0005 % 19 Ω CMC 0,004 % 100 Ω CMC 0,0007 % 190 Ω CMC 0,003 % 1 kΩ CMC 0,0004 % 1,9 kΩ CMC 0,002 % 10 kΩ CMC 0,0004 % 19 kΩ CMC 0,002 % 100 kΩ CMC 0,0006 % 190 kΩ CMC 0,003 % 1 MΩ CMC 0,004 % 1,9 MΩ CMC 0,004 % 10 MΩ CMC 0,006 % 19 MΩ CMC 0,008 % 100 MΩ CMC 0,006 % 1 GΩ CMC 0,014 % 10 GΩ CMC 0,23 % 100 GΩ CMC 0,80 % 200 GΩ CMC 1,0 % 0 Ω az 1 Ω CMC 1,5 mΩ 1 Ω az 5 Ω CMC 0,13 % 5 Ω az 10 Ω CMC 0,021 % 10 Ω az 11 Ω CMC 0,026 % 11 Ω az 20 Ω CMC 0,030 % 20 Ω az 33 Ω CMC 0,023 % 33 Ω az 330 Ω CMC 0,016 % 330 Ω az 1,1 kΩ CMC 0,012 % 1,1 kΩ az 3,3 kΩ CMC 0,013 % 3,3 kΩ az 11 kΩ CMC 0,012 % 11 kΩ az 33 kΩ CMC 0,013 % 33 kΩ az 110 kΩ CMC 0,014 % 110 kΩ az 330 kΩ CMC 0,016 % 330 kΩ az 1,1 MΩ CMC 0,019 % 1,1 MΩ az 3,3 MΩ CMC 0,021 % 3,3 MΩ az 11 MΩ CMC 0,072 % 11 MΩ az 33 MΩ CMC 0,15 % 33 MΩ az 110 MΩ CMC 0,59 % 110 MΩ az 330 MΩ CMC 0,69 % 330 MΩ az 1,1 GΩ CMC 2,0 % TP5, TP21","search_en":"DC resistance / DC resistance meters Calibration – electrical quantities Direct generation with a calibrator 0,1 mΩ CMC 0,005 % 1 mΩ CMC 0,005 % 10 mΩ CMC 0,002 % 100 mΩ CMC 0,001 % 1 Ω CMC 0,0005 % 1,9 Ω CMC 0,02 % 10 Ω CMC 0,0005 % 19 Ω CMC 0,004 % 100 Ω CMC 0,0007 % 190 Ω CMC 0,003 % 1 kΩ CMC 0,0004 % 1,9 kΩ CMC 0,002 % 10 kΩ CMC 0,0004 % 19 kΩ CMC 0,002 % 100 kΩ CMC 0,0006 % 190 kΩ CMC 0,003 % 1 MΩ CMC 0,004 % 1,9 MΩ CMC 0,004 % 10 MΩ CMC 0,006 % 19 MΩ CMC 0,008 % 100 MΩ CMC 0,006 % 1 GΩ CMC 0,014 % 10 GΩ CMC 0,23 % 100 GΩ CMC 0,80 % 200 GΩ CMC 1,0 % 0 Ω to 1 Ω CMC 1,5 mΩ 1 Ω to 5 Ω CMC 0,13 % 5 Ω to 10 Ω CMC 0,021 % 10 Ω to 11 Ω CMC 0,026 % 11 Ω to 20 Ω CMC 0,030 % 20 Ω to 33 Ω CMC 0,023 % 33 Ω to 330 Ω CMC 0,016 % 330 Ω to 1,1 kΩ CMC 0,012 % 1,1 kΩ to 3,3 kΩ CMC 0,013 % 3,3 kΩ to 11 kΩ CMC 0,012 % 11 kΩ to 33 kΩ CMC 0,013 % 33 kΩ to 110 kΩ CMC 0,014 % 110 kΩ to 330 kΩ CMC 0,016 % 330 kΩ to 1,1 MΩ CMC 0,019 % 1,1 MΩ to 3,3 MΩ CMC 0,021 % 3,3 MΩ to 11 MΩ CMC 0,072 % 11 MΩ to 33 MΩ CMC 0,15 % 33 MΩ to 110 MΩ CMC 0,59 % 110 MΩ to 330 MΩ CMC 0,69 % 330 MΩ to 1,1 GΩ CMC 2,0 % TP5, TP21","search_zh":"直流电阻 / 直流电阻测量仪器 校准 – 电学量 用校准器直接产生 0,1 mΩ CMC 0,005 % 1 mΩ CMC 0,005 % 10 mΩ CMC 0,002 % 100 mΩ CMC 0,001 % 1 Ω CMC 0,0005 % 1,9 Ω CMC 0,02 % 10 Ω CMC 0,0005 % 19 Ω CMC 0,004 % 100 Ω CMC 0,0007 % 190 Ω CMC 0,003 % 1 kΩ CMC 0,0004 % 1,9 kΩ CMC 0,002 % 10 kΩ CMC 0,0004 % 19 kΩ CMC 0,002 % 100 kΩ CMC 0,0006 % 190 kΩ CMC 0,003 % 1 MΩ CMC 0,004 % 1,9 MΩ CMC 0,004 % 10 MΩ CMC 0,006 % 19 MΩ CMC 0,008 % 100 MΩ CMC 0,006 % 1 GΩ CMC 0,014 % 10 GΩ CMC 0,23 % 100 GΩ CMC 0,80 % 200 GΩ CMC 1,0 % 0 Ω 至 1 Ω CMC 1,5 mΩ 1 Ω 至 5 Ω CMC 0,13 % 5 Ω 至 10 Ω CMC 0,021 % 10 Ω 至 11 Ω CMC 0,026 % 11 Ω 至 20 Ω CMC 0,030 % 20 Ω 至 33 Ω CMC 0,023 % 33 Ω 至 330 Ω CMC 0,016 % 330 Ω 至 1,1 kΩ CMC 0,012 % 1,1 kΩ 至 3,3 kΩ CMC 0,013 % 3,3 kΩ 至 11 kΩ CMC 0,012 % 11 kΩ 至 33 kΩ CMC 0,013 % 33 kΩ 至 110 kΩ CMC 0,014 % 110 kΩ 至 330 kΩ CMC 0,016 % 330 kΩ 至 1,1 MΩ CMC 0,019 % 1,1 MΩ 至 3,3 MΩ CMC 0,021 % 3,3 MΩ 至 11 MΩ CMC 0,072 % 11 MΩ 至 33 MΩ CMC 0,15 % 33 MΩ 至 110 MΩ CMC 0,59 % 110 MΩ 至 330 MΩ CMC 0,69 % 330 MΩ 至 1,1 GΩ CMC 2,0 % TP5, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b750c2593ca358e3b6029ba","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja przy prądzie przemiennym / Wzorce rezystancji przy prądzie przemiennym dla częstotliwości od 20 Hz do 1 MHz","test_object_en":"AC resistance / AC resistance standards for frequencies from 20 Hz to 1 MHz","test_object_zh":"交流电阻 / 频率 20 Hz 至 1 MHz 的交流电阻标准器","test_object_cs":"Střídavý odpor / Etalony střídavého odporu pro kmitočty 20 Hz až 1 MHz","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 Hz do 100 kHz","range":"od 50 mΩ do 0,1 Ω","cmc":"3,1 %"},{"name":"100 kHz do 300 kHz","range":"od 50 mΩ do 0,1 Ω","cmc":"5,3 %"},{"name":"20 Hz do 50 Hz","range":"od 0,1 Ω do 0,2 Ω","cmc":"4,9 %"},{"name":"50 Hz do 100 Hz","range":"od 0,1 Ω do 0,2 Ω","cmc":"3,5 %"},{"name":"100 Hz do 100 kHz","range":"od 0,1 Ω do 0,2 Ω","cmc":"1,6 %"},{"name":"100 kHz do 300 kHz","range":"od 0,1 Ω do 0,2 Ω","cmc":"2,7 %"},{"name":"300 kHz do 1 MHz","range":"od 0,1 Ω do 0,2 Ω","cmc":"3,9 %"},{"name":"20 Hz do 50 Hz","range":"od 0,2 Ω do 0,5 Ω","cmc":"2,6 %"},{"name":"50 Hz do 100 Hz","range":"od 0,2 Ω do 0,5 Ω","cmc":"1,9 %"},{"name":"100 Hz do 100 kHz","range":"od 0,2 Ω do 0,5 Ω","cmc":"0,85 %"},{"name":"100 kHz do 300 kHz","range":"od 0,2 Ω do 0,5 Ω","cmc":"1,5 %"},{"name":"300 kHz do 1 MHz","range":"od 0,2 Ω do 0,5 Ω","cmc":"2,1 %"},{"name":"20 Hz do 50 Hz","range":"od 0,5 Ω do 1 Ω","cmc":"1,3 %"},{"name":"50 Hz do 100 Hz","range":"od 0,5 Ω do 1 Ω","cmc":"0,83 %"},{"name":"100 Hz do 100 kHz","range":"od 0,5 Ω do 1 Ω","cmc":"0,44 %"},{"name":"100 kHz do 300 kHz","range":"od 0,5 Ω do 1 Ω","cmc":"0,67 %"},{"name":"300 kHz do 1 MHz","range":"od 0,5 Ω do 1 Ω","cmc":"0,90 %"},{"name":"20 Hz do 50 Hz","range":"od 1 Ω do 5 Ω","cmc":"0,78 %"},{"name":"50 Hz do 100 Hz","range":"od 1 Ω do 5 Ω","cmc":"0,49 %"},{"name":"100 Hz do 100 kHz","range":"od 1 Ω do 5 Ω","cmc":"0,30 %"},{"name":"100 kHz do 300 kHz","range":"od 1 Ω do 5 Ω","cmc":"0,41 %"},{"name":"300 kHz do 1 MHz","range":"od 1 Ω do 5 Ω","cmc":"0,53 %"},{"name":"20 Hz do 50 Hz","range":"od 5 Ω do 10 Ω","cmc":"0,42 %"},{"name":"50 Hz do 100 Hz","range":"od 5 Ω do 10 Ω","cmc":"0,23 %"},{"name":"100 Hz do 100 kHz","range":"od 5 Ω do 10 Ω","cmc":"0,19 %"},{"name":"100 kHz do 300 kHz","range":"od 5 Ω do 10 Ω","cmc":"0,21 %"},{"name":"300 kHz do 1 MHz","range":"od 5 Ω do 10 Ω","cmc":"0,23 %"},{"name":"20 Hz do 50 Hz","range":"od 10 Ω do 15 Ω","cmc":"0,38 %"},{"name":"50 Hz do 100 Hz","range":"od 10 Ω do 15 Ω","cmc":"0,20 %"},{"name":"100 Hz do 100 kHz","range":"od 10 Ω do 15 Ω","cmc":"0,18 %"},{"name":"100 kHz do 1 MHz","range":"od 10 Ω do 15 Ω","cmc":"0,20 %"},{"name":"20 Hz do 50 Hz","range":"od 15 Ω do 50 Ω","cmc":"0,36 %"},{"name":"50 Hz do 100 Hz","range":"od 15 Ω do 50 Ω","cmc":"0,18 %"},{"name":"100 Hz do 1 MHz","range":"od 15 Ω do 50 Ω","cmc":"0,13 %"},{"name":"20 Hz do 50 Hz","range":"od 50 Ω do 2 kΩ","cmc":"0,34 %"},{"name":"50 Hz do 100 Hz","range":"od 50 Ω do 2 kΩ","cmc":"0,17 %"},{"name":"100 Hz do 1 MHz","range":"od 50 Ω do 2 kΩ","cmc":"0,12 %"},{"name":"20 Hz do 50 Hz","range":"od 2 kΩ do 4 kΩ","cmc":"0,33 %"},{"name":"50 Hz do 100 Hz","range":"od 2 kΩ do 4 kΩ","cmc":"0,16 %"},{"name":"100 Hz do 300 kHz","range":"od 2 kΩ do 4 kΩ","cmc":"0,11 %"},{"name":"300 kHz do 1 MHz","range":"od 2 kΩ do 4 kΩ","cmc":"0,17 %"},{"name":"20 Hz do 50 Hz","range":"od 4 kΩ do 20 kΩ","cmc":"0,34 %"},{"name":"50 Hz do 100 Hz","range":"od 4 kΩ do 20 kΩ","cmc":"0,16 %"},{"name":"100 Hz do 100 kHz","range":"od 4 kΩ do 20 kΩ","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 4 kΩ do 20 kΩ","cmc":"0,17 %"},{"name":"300 kHz do 1 MHz","range":"od 4 kΩ do 20 kΩ","cmc":"0,19 %"},{"name":"20 Hz do 50 Hz","range":"od 20 kΩ do 100 kΩ","cmc":"0,37 %"},{"name":"50 Hz do 100 Hz","range":"od 20 kΩ do 100 kΩ","cmc":"0,19 %"},{"name":"100 Hz do 30 kHz","range":"od 20 kΩ do 100 kΩ","cmc":"0,13 %"},{"name":"30 kHz do 100 kHz","range":"od 20 kΩ do 100 kΩ","cmc":"0,17 %"},{"name":"100 kHz do 300 kHz","range":"od 20 kΩ do 100 kΩ","cmc":"0,20 %"},{"name":"300 kHz do 1 MHz","range":"od 20 kΩ do 100 kΩ","cmc":"0,28 %"},{"name":"20 Hz do 50 Hz","range":"od 100 kΩ do 320 kΩ","cmc":"0,46 %"},{"name":"50 Hz do 100 Hz","range":"od 100 kΩ do 320 kΩ","cmc":"0,26 %"},{"name":"100 Hz do 30 kHz","range":"od 100 kΩ do 320 kΩ","cmc":"0,15 %"},{"name":"30 kHz do 100 kHz","range":"od 100 kΩ do 320 kΩ","cmc":"0,20 %"},{"name":"100 kHz do 300 kHz","range":"od 100 kΩ do 320 kΩ","cmc":"0,28 %"},{"name":"300 kHz do 1 MHz","range":"od 100 kΩ do 320 kΩ","cmc":"0,55 %"},{"name":"20 Hz do 50 Hz","range":"od 320 kΩ do 400 kΩ","cmc":"0,49 %"},{"name":"50 Hz do 100 Hz","range":"od 320 kΩ do 400 kΩ","cmc":"0,28 %"},{"name":"100 Hz do 100 kHz","range":"od 320 kΩ do 400 kΩ","cmc":"0,21 %"},{"name":"100 kHz do 300 kHz","range":"od 320 kΩ do 400 kΩ","cmc":"0,31 %"},{"name":"300 kHz do 1 MHz","range":"od 320 kΩ do 400 kΩ","cmc":"0,65 %"},{"name":"20 Hz do 50 Hz","range":"od 400 kΩ do 500 kΩ","cmc":"0,53 %"},{"name":"50 Hz do 100 Hz","range":"od 400 kΩ do 500 kΩ","cmc":"0,31 %"},{"name":"100 Hz do 100 kHz","range":"od 400 kΩ do 500 kΩ","cmc":"0,22 %"},{"name":"100 kHz do 300 kHz","range":"od 400 kΩ do 500 kΩ","cmc":"0,34 %"},{"name":"300 kHz do 1 MHz","range":"od 400 kΩ do 500 kΩ","cmc":"0,77 %"},{"name":"20 Hz do 50 Hz","range":"od 500 kΩ do 700 kΩ","cmc":"0,61 %"},{"name":"50 Hz do 100 Hz","range":"od 500 kΩ do 700 kΩ","cmc":"0,37 %"},{"name":"100 Hz do 100 kHz","range":"od 500 kΩ do 700 kΩ","cmc":"0,25 %"},{"name":"100 kHz do 300 kHz","range":"od 500 kΩ do 700 kΩ","cmc":"0,42 %"},{"name":"300 kHz do 1 MHz","range":"od 500 kΩ do 700 kΩ","cmc":"1,1 %"},{"name":"20 Hz do 50 Hz","range":"od 700 kΩ do 900 kΩ","cmc":"0,69 %"},{"name":"50 Hz do 100 Hz","range":"od 700 kΩ do 900 kΩ","cmc":"0,43 %"},{"name":"100 Hz do 100 kHz","range":"od 700 kΩ do 900 kΩ","cmc":"0,27 %"},{"name":"100 kHz do 300 kHz","range":"od 700 kΩ do 900 kΩ","cmc":"0,49 %"},{"name":"300 kHz do 1 MHz","range":"od 700 kΩ do 900 kΩ","cmc":"1,3 %"},{"name":"20 Hz do 50 Hz","range":"od 900 kΩ do 1 MΩ","cmc":"0,73 %"},{"name":"50 Hz do 100 Hz","range":"od 900 kΩ do 1 MΩ","cmc":"0,46 %"},{"name":"100 Hz do 100 kHz","range":"od 900 kΩ do 1 MΩ","cmc":"0,28 %"},{"name":"100 kHz do 300 kHz","range":"od 900 kΩ do 1 MΩ","cmc":"0,53 %"},{"name":"300 kHz do 1 MHz","range":"od 900 kΩ do 1 MΩ","cmc":"1,4 %"},{"name":"20 Hz do 50 Hz","range":"od 1 MΩ do 2 MΩ","cmc":"1,2 %"},{"name":"50 Hz do 100 Hz","range":"od 1 MΩ do 2 MΩ","cmc":"0,75 %"},{"name":"100 Hz do 100 kHz","range":"od 1 MΩ do 2 MΩ","cmc":"0,41 %"},{"name":"100 kHz do 300 kHz","range":"od 1 MΩ do 2 MΩ","cmc":"0,90 %"},{"name":"300 kHz do 1 MHz","range":"od 1 MΩ do 2 MΩ","cmc":"2,7 %"},{"name":"20 Hz do 50 Hz","range":"od 2 MΩ do 4 MΩ","cmc":"2,0 %"},{"name":"50 Hz do 100 Hz","range":"od 2 MΩ do 4 MΩ","cmc":"1,4 %"},{"name":"100 Hz do 100 kHz","range":"od 2 MΩ do 4 MΩ","cmc":"0,65 %"},{"name":"100 kHz do 300 kHz","range":"od 2 MΩ do 4 MΩ","cmc":"1,7 %"},{"name":"300 kHz do 1 MHz","range":"od 2 MΩ do 4 MΩ","cmc":"5,1 %"},{"name":"20 Hz do 50 Hz","range":"od 4 MΩ do 6 MΩ","cmc":"2,8 %"},{"name":"50 Hz do 100 Hz","range":"od 4 MΩ do 6 MΩ","cmc":"2,0 %"},{"name":"100 Hz do 100 kHz","range":"od 4 MΩ do 6 MΩ","cmc":"0,90 %"},{"name":"100 kHz do 300 kHz","range":"od 4 MΩ do 6 MΩ","cmc":"2,4 %"},{"name":"300 kHz do 1 MHz","range":"od 4 MΩ do 6 MΩ","cmc":"7,6 %"},{"name":"20 Hz do 50 Hz","range":"od 6 MΩ do 8 MΩ","cmc":"3,6 %"},{"name":"50 Hz do 100 Hz","range":"od 6 MΩ do 8 MΩ","cmc":"2,6 %"},{"name":"100 Hz do 100 kHz","range":"od 6 MΩ do 8 MΩ","cmc":"1,2 %"},{"name":"100 kHz do 300 kHz","range":"od 6 MΩ do 8 MΩ","cmc":"3,2 %"},{"name":"20 Hz do 50 Hz","range":"od 8 MΩ do 10 MΩ","cmc":"4,4 %"},{"name":"50 Hz do 100 Hz","range":"od 8 MΩ do 10 MΩ","cmc":"3,2 %"},{"name":"100 Hz do 100 kHz","range":"od 8 MΩ do 10 MΩ","cmc":"1,4 %"},{"name":"100 kHz do 300 kHz","range":"od 8 MΩ do 10 MΩ","cmc":"3,9 %"},{"name":"20 Hz do 50 Hz","range":"od 10 MΩ do 15 MΩ","cmc":"6,4 %"},{"name":"50 Hz do 100 Hz","range":"od 10 MΩ do 15 MΩ","cmc":"4,8 %"},{"name":"100 Hz do 100 kHz","range":"od 10 MΩ do 15 MΩ","cmc":"2,2 %"},{"name":"100 kHz do 300 kHz","range":"od 10 MΩ do 15 MΩ","cmc":"5,8 %"},{"name":"20 Hz do 50 Hz","range":"od 15 MΩ do 20 MΩ","cmc":"8,4 %"},{"name":"50 Hz do 100 Hz","range":"od 15 MΩ do 20 MΩ","cmc":"6,3 %"},{"name":"100 Hz do 100 kHz","range":"od 15 MΩ do 20 MΩ","cmc":"2,8 %"},{"name":"100 kHz do 300 kHz","range":"od 15 MΩ do 20 MΩ","cmc":"7,6 %"},{"name":"100 Hz do 1 kHz","range":"od 20 MΩ do 25 MΩ","cmc":"3,5 %"},{"name":"1 kHz do 100 kHz","range":"od 20 MΩ do 25 MΩ","cmc":"3,3 %"},{"name":"100 Hz do 1 kHz","range":"od 25 MΩ do 30 MΩ","cmc":"4,1 %"},{"name":"1 kHz do 100 kHz","range":"od 25 MΩ do 30 MΩ","cmc":"3,9 %"}],"parameters_en":[{"name":"100 Hz to 100 kHz","range":"50 mΩ to 0,1 Ω","cmc":"3,1 %"},{"name":"100 kHz to 300 kHz","range":"50 mΩ to 0,1 Ω","cmc":"5,3 %"},{"name":"20 Hz to 50 Hz","range":"0,1 Ω to 0,2 Ω","cmc":"4,9 %"},{"name":"50 Hz to 100 Hz","range":"0,1 Ω to 0,2 Ω","cmc":"3,5 %"},{"name":"100 Hz to 100 kHz","range":"0,1 Ω to 0,2 Ω","cmc":"1,6 %"},{"name":"100 kHz to 300 kHz","range":"0,1 Ω to 0,2 Ω","cmc":"2,7 %"},{"name":"300 kHz to 1 MHz","range":"0,1 Ω to 0,2 Ω","cmc":"3,9 %"},{"name":"20 Hz to 50 Hz","range":"0,2 Ω to 0,5 Ω","cmc":"2,6 %"},{"name":"50 Hz to 100 Hz","range":"0,2 Ω to 0,5 Ω","cmc":"1,9 %"},{"name":"100 Hz to 100 kHz","range":"0,2 Ω to 0,5 Ω","cmc":"0,85 %"},{"name":"100 kHz to 300 kHz","range":"0,2 Ω to 0,5 Ω","cmc":"1,5 %"},{"name":"300 kHz to 1 MHz","range":"0,2 Ω to 0,5 Ω","cmc":"2,1 %"},{"name":"20 Hz to 50 Hz","range":"0,5 Ω to 1 Ω","cmc":"1,3 %"},{"name":"50 Hz to 100 Hz","range":"0,5 Ω to 1 Ω","cmc":"0,83 %"},{"name":"100 Hz to 100 kHz","range":"0,5 Ω to 1 Ω","cmc":"0,44 %"},{"name":"100 kHz to 300 kHz","range":"0,5 Ω to 1 Ω","cmc":"0,67 %"},{"name":"300 kHz to 1 MHz","range":"0,5 Ω to 1 Ω","cmc":"0,90 %"},{"name":"20 Hz to 50 Hz","range":"1 Ω to 5 Ω","cmc":"0,78 %"},{"name":"50 Hz to 100 Hz","range":"1 Ω to 5 Ω","cmc":"0,49 %"},{"name":"100 Hz to 100 kHz","range":"1 Ω to 5 Ω","cmc":"0,30 %"},{"name":"100 kHz to 300 kHz","range":"1 Ω to 5 Ω","cmc":"0,41 %"},{"name":"300 kHz to 1 MHz","range":"1 Ω to 5 Ω","cmc":"0,53 %"},{"name":"20 Hz to 50 Hz","range":"5 Ω to 10 Ω","cmc":"0,42 %"},{"name":"50 Hz to 100 Hz","range":"5 Ω to 10 Ω","cmc":"0,23 %"},{"name":"100 Hz to 100 kHz","range":"5 Ω to 10 Ω","cmc":"0,19 %"},{"name":"100 kHz to 300 kHz","range":"5 Ω to 10 Ω","cmc":"0,21 %"},{"name":"300 kHz to 1 MHz","range":"5 Ω to 10 Ω","cmc":"0,23 %"},{"name":"20 Hz to 50 Hz","range":"10 Ω to 15 Ω","cmc":"0,38 %"},{"name":"50 Hz to 100 Hz","range":"10 Ω to 15 Ω","cmc":"0,20 %"},{"name":"100 Hz to 100 kHz","range":"10 Ω to 15 Ω","cmc":"0,18 %"},{"name":"100 kHz to 1 MHz","range":"10 Ω to 15 Ω","cmc":"0,20 %"},{"name":"20 Hz to 50 Hz","range":"15 Ω to 50 Ω","cmc":"0,36 %"},{"name":"50 Hz to 100 Hz","range":"15 Ω to 50 Ω","cmc":"0,18 %"},{"name":"100 Hz to 1 MHz","range":"15 Ω to 50 Ω","cmc":"0,13 %"},{"name":"20 Hz to 50 Hz","range":"50 Ω to 2 kΩ","cmc":"0,34 %"},{"name":"50 Hz to 100 Hz","range":"50 Ω to 2 kΩ","cmc":"0,17 %"},{"name":"100 Hz to 1 MHz","range":"50 Ω to 2 kΩ","cmc":"0,12 %"},{"name":"20 Hz to 50 Hz","range":"2 kΩ to 4 kΩ","cmc":"0,33 %"},{"name":"50 Hz to 100 Hz","range":"2 kΩ to 4 kΩ","cmc":"0,16 %"},{"name":"100 Hz to 300 kHz","range":"2 kΩ to 4 kΩ","cmc":"0,11 %"},{"name":"300 kHz to 1 MHz","range":"2 kΩ to 4 kΩ","cmc":"0,17 %"},{"name":"20 Hz to 50 Hz","range":"4 kΩ to 20 kΩ","cmc":"0,34 %"},{"name":"50 Hz to 100 Hz","range":"4 kΩ to 20 kΩ","cmc":"0,16 %"},{"name":"100 Hz to 100 kHz","range":"4 kΩ to 20 kΩ","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"4 kΩ to 20 kΩ","cmc":"0,17 %"},{"name":"300 kHz to 1 MHz","range":"4 kΩ to 20 kΩ","cmc":"0,19 %"},{"name":"20 Hz to 50 Hz","range":"20 kΩ to 100 kΩ","cmc":"0,37 %"},{"name":"50 Hz to 100 Hz","range":"20 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"100 Hz to 30 kHz","range":"20 kΩ to 100 kΩ","cmc":"0,13 %"},{"name":"30 kHz to 100 kHz","range":"20 kΩ to 100 kΩ","cmc":"0,17 %"},{"name":"100 kHz to 300 kHz","range":"20 kΩ to 100 kΩ","cmc":"0,20 %"},{"name":"300 kHz to 1 MHz","range":"20 kΩ to 100 kΩ","cmc":"0,28 %"},{"name":"20 Hz to 50 Hz","range":"100 kΩ to 320 kΩ","cmc":"0,46 %"},{"name":"50 Hz to 100 Hz","range":"100 kΩ to 320 kΩ","cmc":"0,26 %"},{"name":"100 Hz to 30 kHz","range":"100 kΩ to 320 kΩ","cmc":"0,15 %"},{"name":"30 kHz to 100 kHz","range":"100 kΩ to 320 kΩ","cmc":"0,20 %"},{"name":"100 kHz to 300 kHz","range":"100 kΩ to 320 kΩ","cmc":"0,28 %"},{"name":"300 kHz to 1 MHz","range":"100 kΩ to 320 kΩ","cmc":"0,55 %"},{"name":"20 Hz to 50 Hz","range":"320 kΩ to 400 kΩ","cmc":"0,49 %"},{"name":"50 Hz to 100 Hz","range":"320 kΩ to 400 kΩ","cmc":"0,28 %"},{"name":"100 Hz to 100 kHz","range":"320 kΩ to 400 kΩ","cmc":"0,21 %"},{"name":"100 kHz to 300 kHz","range":"320 kΩ to 400 kΩ","cmc":"0,31 %"},{"name":"300 kHz to 1 MHz","range":"320 kΩ to 400 kΩ","cmc":"0,65 %"},{"name":"20 Hz to 50 Hz","range":"400 kΩ to 500 kΩ","cmc":"0,53 %"},{"name":"50 Hz to 100 Hz","range":"400 kΩ to 500 kΩ","cmc":"0,31 %"},{"name":"100 Hz to 100 kHz","range":"400 kΩ to 500 kΩ","cmc":"0,22 %"},{"name":"100 kHz to 300 kHz","range":"400 kΩ to 500 kΩ","cmc":"0,34 %"},{"name":"300 kHz to 1 MHz","range":"400 kΩ to 500 kΩ","cmc":"0,77 %"},{"name":"20 Hz to 50 Hz","range":"500 kΩ to 700 kΩ","cmc":"0,61 %"},{"name":"50 Hz to 100 Hz","range":"500 kΩ to 700 kΩ","cmc":"0,37 %"},{"name":"100 Hz to 100 kHz","range":"500 kΩ to 700 kΩ","cmc":"0,25 %"},{"name":"100 kHz to 300 kHz","range":"500 kΩ to 700 kΩ","cmc":"0,42 %"},{"name":"300 kHz to 1 MHz","range":"500 kΩ to 700 kΩ","cmc":"1,1 %"},{"name":"20 Hz to 50 Hz","range":"700 kΩ to 900 kΩ","cmc":"0,69 %"},{"name":"50 Hz to 100 Hz","range":"700 kΩ to 900 kΩ","cmc":"0,43 %"},{"name":"100 Hz to 100 kHz","range":"700 kΩ to 900 kΩ","cmc":"0,27 %"},{"name":"100 kHz to 300 kHz","range":"700 kΩ to 900 kΩ","cmc":"0,49 %"},{"name":"300 kHz to 1 MHz","range":"700 kΩ to 900 kΩ","cmc":"1,3 %"},{"name":"20 Hz to 50 Hz","range":"900 kΩ to 1 MΩ","cmc":"0,73 %"},{"name":"50 Hz to 100 Hz","range":"900 kΩ to 1 MΩ","cmc":"0,46 %"},{"name":"100 Hz to 100 kHz","range":"900 kΩ to 1 MΩ","cmc":"0,28 %"},{"name":"100 kHz to 300 kHz","range":"900 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"300 kHz to 1 MHz","range":"900 kΩ to 1 MΩ","cmc":"1,4 %"},{"name":"20 Hz to 50 Hz","range":"1 MΩ to 2 MΩ","cmc":"1,2 %"},{"name":"50 Hz to 100 Hz","range":"1 MΩ to 2 MΩ","cmc":"0,75 %"},{"name":"100 Hz to 100 kHz","range":"1 MΩ to 2 MΩ","cmc":"0,41 %"},{"name":"100 kHz to 300 kHz","range":"1 MΩ to 2 MΩ","cmc":"0,90 %"},{"name":"300 kHz to 1 MHz","range":"1 MΩ to 2 MΩ","cmc":"2,7 %"},{"name":"20 Hz to 50 Hz","range":"2 MΩ to 4 MΩ","cmc":"2,0 %"},{"name":"50 Hz to 100 Hz","range":"2 MΩ to 4 MΩ","cmc":"1,4 %"},{"name":"100 Hz to 100 kHz","range":"2 MΩ to 4 MΩ","cmc":"0,65 %"},{"name":"100 kHz to 300 kHz","range":"2 MΩ to 4 MΩ","cmc":"1,7 %"},{"name":"300 kHz to 1 MHz","range":"2 MΩ to 4 MΩ","cmc":"5,1 %"},{"name":"20 Hz to 50 Hz","range":"4 MΩ to 6 MΩ","cmc":"2,8 %"},{"name":"50 Hz to 100 Hz","range":"4 MΩ to 6 MΩ","cmc":"2,0 %"},{"name":"100 Hz to 100 kHz","range":"4 MΩ to 6 MΩ","cmc":"0,90 %"},{"name":"100 kHz to 300 kHz","range":"4 MΩ to 6 MΩ","cmc":"2,4 %"},{"name":"300 kHz to 1 MHz","range":"4 MΩ to 6 MΩ","cmc":"7,6 %"},{"name":"20 Hz to 50 Hz","range":"6 MΩ to 8 MΩ","cmc":"3,6 %"},{"name":"50 Hz to 100 Hz","range":"6 MΩ to 8 MΩ","cmc":"2,6 %"},{"name":"100 Hz to 100 kHz","range":"6 MΩ to 8 MΩ","cmc":"1,2 %"},{"name":"100 kHz to 300 kHz","range":"6 MΩ to 8 MΩ","cmc":"3,2 %"},{"name":"20 Hz to 50 Hz","range":"8 MΩ to 10 MΩ","cmc":"4,4 %"},{"name":"50 Hz to 100 Hz","range":"8 MΩ to 10 MΩ","cmc":"3,2 %"},{"name":"100 Hz to 100 kHz","range":"8 MΩ to 10 MΩ","cmc":"1,4 %"},{"name":"100 kHz to 300 kHz","range":"8 MΩ to 10 MΩ","cmc":"3,9 %"},{"name":"20 Hz to 50 Hz","range":"10 MΩ to 15 MΩ","cmc":"6,4 %"},{"name":"50 Hz to 100 Hz","range":"10 MΩ to 15 MΩ","cmc":"4,8 %"},{"name":"100 Hz to 100 kHz","range":"10 MΩ to 15 MΩ","cmc":"2,2 %"},{"name":"100 kHz to 300 kHz","range":"10 MΩ to 15 MΩ","cmc":"5,8 %"},{"name":"20 Hz to 50 Hz","range":"15 MΩ to 20 MΩ","cmc":"8,4 %"},{"name":"50 Hz to 100 Hz","range":"15 MΩ to 20 MΩ","cmc":"6,3 %"},{"name":"100 Hz to 100 kHz","range":"15 MΩ to 20 MΩ","cmc":"2,8 %"},{"name":"100 kHz to 300 kHz","range":"15 MΩ to 20 MΩ","cmc":"7,6 %"},{"name":"100 Hz to 1 kHz","range":"20 MΩ to 25 MΩ","cmc":"3,5 %"},{"name":"1 kHz to 100 kHz","range":"20 MΩ to 25 MΩ","cmc":"3,3 %"},{"name":"100 Hz to 1 kHz","range":"25 MΩ to 30 MΩ","cmc":"4,1 %"},{"name":"1 kHz to 100 kHz","range":"25 MΩ to 30 MΩ","cmc":"3,9 %"}],"parameters_zh":[{"name":"100 Hz 至 100 kHz","range":"50 mΩ 至 0,1 Ω","cmc":"3,1 %"},{"name":"100 kHz 至 300 kHz","range":"50 mΩ 至 0,1 Ω","cmc":"5,3 %"},{"name":"20 Hz 至 50 Hz","range":"0,1 Ω 至 0,2 Ω","cmc":"4,9 %"},{"name":"50 Hz 至 100 Hz","range":"0,1 Ω 至 0,2 Ω","cmc":"3,5 %"},{"name":"100 Hz 至 100 kHz","range":"0,1 Ω 至 0,2 Ω","cmc":"1,6 %"},{"name":"100 kHz 至 300 kHz","range":"0,1 Ω 至 0,2 Ω","cmc":"2,7 %"},{"name":"300 kHz 至 1 MHz","range":"0,1 Ω 至 0,2 Ω","cmc":"3,9 %"},{"name":"20 Hz 至 50 Hz","range":"0,2 Ω 至 0,5 Ω","cmc":"2,6 %"},{"name":"50 Hz 至 100 Hz","range":"0,2 Ω 至 0,5 Ω","cmc":"1,9 %"},{"name":"100 Hz 至 100 kHz","range":"0,2 Ω 至 0,5 Ω","cmc":"0,85 %"},{"name":"100 kHz 至 300 kHz","range":"0,2 Ω 至 0,5 Ω","cmc":"1,5 %"},{"name":"300 kHz 至 1 MHz","range":"0,2 Ω 至 0,5 Ω","cmc":"2,1 %"},{"name":"20 Hz 至 50 Hz","range":"0,5 Ω 至 1 Ω","cmc":"1,3 %"},{"name":"50 Hz 至 100 Hz","range":"0,5 Ω 至 1 Ω","cmc":"0,83 %"},{"name":"100 Hz 至 100 kHz","range":"0,5 Ω 至 1 Ω","cmc":"0,44 %"},{"name":"100 kHz 至 300 kHz","range":"0,5 Ω 至 1 Ω","cmc":"0,67 %"},{"name":"300 kHz 至 1 MHz","range":"0,5 Ω 至 1 Ω","cmc":"0,90 %"},{"name":"20 Hz 至 50 Hz","range":"1 Ω 至 5 Ω","cmc":"0,78 %"},{"name":"50 Hz 至 100 Hz","range":"1 Ω 至 5 Ω","cmc":"0,49 %"},{"name":"100 Hz 至 100 kHz","range":"1 Ω 至 5 Ω","cmc":"0,30 %"},{"name":"100 kHz 至 300 kHz","range":"1 Ω 至 5 Ω","cmc":"0,41 %"},{"name":"300 kHz 至 1 MHz","range":"1 Ω 至 5 Ω","cmc":"0,53 %"},{"name":"20 Hz 至 50 Hz","range":"5 Ω 至 10 Ω","cmc":"0,42 %"},{"name":"50 Hz 至 100 Hz","range":"5 Ω 至 10 Ω","cmc":"0,23 %"},{"name":"100 Hz 至 100 kHz","range":"5 Ω 至 10 Ω","cmc":"0,19 %"},{"name":"100 kHz 至 300 kHz","range":"5 Ω 至 10 Ω","cmc":"0,21 %"},{"name":"300 kHz 至 1 MHz","range":"5 Ω 至 10 Ω","cmc":"0,23 %"},{"name":"20 Hz 至 50 Hz","range":"10 Ω 至 15 Ω","cmc":"0,38 %"},{"name":"50 Hz 至 100 Hz","range":"10 Ω 至 15 Ω","cmc":"0,20 %"},{"name":"100 Hz 至 100 kHz","range":"10 Ω 至 15 Ω","cmc":"0,18 %"},{"name":"100 kHz 至 1 MHz","range":"10 Ω 至 15 Ω","cmc":"0,20 %"},{"name":"20 Hz 至 50 Hz","range":"15 Ω 至 50 Ω","cmc":"0,36 %"},{"name":"50 Hz 至 100 Hz","range":"15 Ω 至 50 Ω","cmc":"0,18 %"},{"name":"100 Hz 至 1 MHz","range":"15 Ω 至 50 Ω","cmc":"0,13 %"},{"name":"20 Hz 至 50 Hz","range":"50 Ω 至 2 kΩ","cmc":"0,34 %"},{"name":"50 Hz 至 100 Hz","range":"50 Ω 至 2 kΩ","cmc":"0,17 %"},{"name":"100 Hz 至 1 MHz","range":"50 Ω 至 2 kΩ","cmc":"0,12 %"},{"name":"20 Hz 至 50 Hz","range":"2 kΩ 至 4 kΩ","cmc":"0,33 %"},{"name":"50 Hz 至 100 Hz","range":"2 kΩ 至 4 kΩ","cmc":"0,16 %"},{"name":"100 Hz 至 300 kHz","range":"2 kΩ 至 4 kΩ","cmc":"0,11 %"},{"name":"300 kHz 至 1 MHz","range":"2 kΩ 至 4 kΩ","cmc":"0,17 %"},{"name":"20 Hz 至 50 Hz","range":"4 kΩ 至 20 kΩ","cmc":"0,34 %"},{"name":"50 Hz 至 100 Hz","range":"4 kΩ 至 20 kΩ","cmc":"0,16 %"},{"name":"100 Hz 至 100 kHz","range":"4 kΩ 至 20 kΩ","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"4 kΩ 至 20 kΩ","cmc":"0,17 %"},{"name":"300 kHz 至 1 MHz","range":"4 kΩ 至 20 kΩ","cmc":"0,19 %"},{"name":"20 Hz 至 50 Hz","range":"20 kΩ 至 100 kΩ","cmc":"0,37 %"},{"name":"50 Hz 至 100 Hz","range":"20 kΩ 至 100 kΩ","cmc":"0,19 %"},{"name":"100 Hz 至 30 kHz","range":"20 kΩ 至 100 kΩ","cmc":"0,13 %"},{"name":"30 kHz 至 100 kHz","range":"20 kΩ 至 100 kΩ","cmc":"0,17 %"},{"name":"100 kHz 至 300 kHz","range":"20 kΩ 至 100 kΩ","cmc":"0,20 %"},{"name":"300 kHz 至 1 MHz","range":"20 kΩ 至 100 kΩ","cmc":"0,28 %"},{"name":"20 Hz 至 50 Hz","range":"100 kΩ 至 320 kΩ","cmc":"0,46 %"},{"name":"50 Hz 至 100 Hz","range":"100 kΩ 至 320 kΩ","cmc":"0,26 %"},{"name":"100 Hz 至 30 kHz","range":"100 kΩ 至 320 kΩ","cmc":"0,15 %"},{"name":"30 kHz 至 100 kHz","range":"100 kΩ 至 320 kΩ","cmc":"0,20 %"},{"name":"100 kHz 至 300 kHz","range":"100 kΩ 至 320 kΩ","cmc":"0,28 %"},{"name":"300 kHz 至 1 MHz","range":"100 kΩ 至 320 kΩ","cmc":"0,55 %"},{"name":"20 Hz 至 50 Hz","range":"320 kΩ 至 400 kΩ","cmc":"0,49 %"},{"name":"50 Hz 至 100 Hz","range":"320 kΩ 至 400 kΩ","cmc":"0,28 %"},{"name":"100 Hz 至 100 kHz","range":"320 kΩ 至 400 kΩ","cmc":"0,21 %"},{"name":"100 kHz 至 300 kHz","range":"320 kΩ 至 400 kΩ","cmc":"0,31 %"},{"name":"300 kHz 至 1 MHz","range":"320 kΩ 至 400 kΩ","cmc":"0,65 %"},{"name":"20 Hz 至 50 Hz","range":"400 kΩ 至 500 kΩ","cmc":"0,53 %"},{"name":"50 Hz 至 100 Hz","range":"400 kΩ 至 500 kΩ","cmc":"0,31 %"},{"name":"100 Hz 至 100 kHz","range":"400 kΩ 至 500 kΩ","cmc":"0,22 %"},{"name":"100 kHz 至 300 kHz","range":"400 kΩ 至 500 kΩ","cmc":"0,34 %"},{"name":"300 kHz 至 1 MHz","range":"400 kΩ 至 500 kΩ","cmc":"0,77 %"},{"name":"20 Hz 至 50 Hz","range":"500 kΩ 至 700 kΩ","cmc":"0,61 %"},{"name":"50 Hz 至 100 Hz","range":"500 kΩ 至 700 kΩ","cmc":"0,37 %"},{"name":"100 Hz 至 100 kHz","range":"500 kΩ 至 700 kΩ","cmc":"0,25 %"},{"name":"100 kHz 至 300 kHz","range":"500 kΩ 至 700 kΩ","cmc":"0,42 %"},{"name":"300 kHz 至 1 MHz","range":"500 kΩ 至 700 kΩ","cmc":"1,1 %"},{"name":"20 Hz 至 50 Hz","range":"700 kΩ 至 900 kΩ","cmc":"0,69 %"},{"name":"50 Hz 至 100 Hz","range":"700 kΩ 至 900 kΩ","cmc":"0,43 %"},{"name":"100 Hz 至 100 kHz","range":"700 kΩ 至 900 kΩ","cmc":"0,27 %"},{"name":"100 kHz 至 300 kHz","range":"700 kΩ 至 900 kΩ","cmc":"0,49 %"},{"name":"300 kHz 至 1 MHz","range":"700 kΩ 至 900 kΩ","cmc":"1,3 %"},{"name":"20 Hz 至 50 Hz","range":"900 kΩ 至 1 MΩ","cmc":"0,73 %"},{"name":"50 Hz 至 100 Hz","range":"900 kΩ 至 1 MΩ","cmc":"0,46 %"},{"name":"100 Hz 至 100 kHz","range":"900 kΩ 至 1 MΩ","cmc":"0,28 %"},{"name":"100 kHz 至 300 kHz","range":"900 kΩ 至 1 MΩ","cmc":"0,53 %"},{"name":"300 kHz 至 1 MHz","range":"900 kΩ 至 1 MΩ","cmc":"1,4 %"},{"name":"20 Hz 至 50 Hz","range":"1 MΩ 至 2 MΩ","cmc":"1,2 %"},{"name":"50 Hz 至 100 Hz","range":"1 MΩ 至 2 MΩ","cmc":"0,75 %"},{"name":"100 Hz 至 100 kHz","range":"1 MΩ 至 2 MΩ","cmc":"0,41 %"},{"name":"100 kHz 至 300 kHz","range":"1 MΩ 至 2 MΩ","cmc":"0,90 %"},{"name":"300 kHz 至 1 MHz","range":"1 MΩ 至 2 MΩ","cmc":"2,7 %"},{"name":"20 Hz 至 50 Hz","range":"2 MΩ 至 4 MΩ","cmc":"2,0 %"},{"name":"50 Hz 至 100 Hz","range":"2 MΩ 至 4 MΩ","cmc":"1,4 %"},{"name":"100 Hz 至 100 kHz","range":"2 MΩ 至 4 MΩ","cmc":"0,65 %"},{"name":"100 kHz 至 300 kHz","range":"2 MΩ 至 4 MΩ","cmc":"1,7 %"},{"name":"300 kHz 至 1 MHz","range":"2 MΩ 至 4 MΩ","cmc":"5,1 %"},{"name":"20 Hz 至 50 Hz","range":"4 MΩ 至 6 MΩ","cmc":"2,8 %"},{"name":"50 Hz 至 100 Hz","range":"4 MΩ 至 6 MΩ","cmc":"2,0 %"},{"name":"100 Hz 至 100 kHz","range":"4 MΩ 至 6 MΩ","cmc":"0,90 %"},{"name":"100 kHz 至 300 kHz","range":"4 MΩ 至 6 MΩ","cmc":"2,4 %"},{"name":"300 kHz 至 1 MHz","range":"4 MΩ 至 6 MΩ","cmc":"7,6 %"},{"name":"20 Hz 至 50 Hz","range":"6 MΩ 至 8 MΩ","cmc":"3,6 %"},{"name":"50 Hz 至 100 Hz","range":"6 MΩ 至 8 MΩ","cmc":"2,6 %"},{"name":"100 Hz 至 100 kHz","range":"6 MΩ 至 8 MΩ","cmc":"1,2 %"},{"name":"100 kHz 至 300 kHz","range":"6 MΩ 至 8 MΩ","cmc":"3,2 %"},{"name":"20 Hz 至 50 Hz","range":"8 MΩ 至 10 MΩ","cmc":"4,4 %"},{"name":"50 Hz 至 100 Hz","range":"8 MΩ 至 10 MΩ","cmc":"3,2 %"},{"name":"100 Hz 至 100 kHz","range":"8 MΩ 至 10 MΩ","cmc":"1,4 %"},{"name":"100 kHz 至 300 kHz","range":"8 MΩ 至 10 MΩ","cmc":"3,9 %"},{"name":"20 Hz 至 50 Hz","range":"10 MΩ 至 15 MΩ","cmc":"6,4 %"},{"name":"50 Hz 至 100 Hz","range":"10 MΩ 至 15 MΩ","cmc":"4,8 %"},{"name":"100 Hz 至 100 kHz","range":"10 MΩ 至 15 MΩ","cmc":"2,2 %"},{"name":"100 kHz 至 300 kHz","range":"10 MΩ 至 15 MΩ","cmc":"5,8 %"},{"name":"20 Hz 至 50 Hz","range":"15 MΩ 至 20 MΩ","cmc":"8,4 %"},{"name":"50 Hz 至 100 Hz","range":"15 MΩ 至 20 MΩ","cmc":"6,3 %"},{"name":"100 Hz 至 100 kHz","range":"15 MΩ 至 20 MΩ","cmc":"2,8 %"},{"name":"100 kHz 至 300 kHz","range":"15 MΩ 至 20 MΩ","cmc":"7,6 %"},{"name":"100 Hz 至 1 kHz","range":"20 MΩ 至 25 MΩ","cmc":"3,5 %"},{"name":"1 kHz 至 100 kHz","range":"20 MΩ 至 25 MΩ","cmc":"3,3 %"},{"name":"100 Hz 至 1 kHz","range":"25 MΩ 至 30 MΩ","cmc":"4,1 %"},{"name":"1 kHz 至 100 kHz","range":"25 MΩ 至 30 MΩ","cmc":"3,9 %"}],"parameters_cs":[{"name":"100 Hz až 100 kHz","range":"50 mΩ až 0,1 Ω","cmc":"3,1 %"},{"name":"100 kHz až 300 kHz","range":"50 mΩ až 0,1 Ω","cmc":"5,3 %"},{"name":"20 Hz až 50 Hz","range":"0,1 Ω až 0,2 Ω","cmc":"4,9 %"},{"name":"50 Hz až 100 Hz","range":"0,1 Ω až 0,2 Ω","cmc":"3,5 %"},{"name":"100 Hz až 100 kHz","range":"0,1 Ω až 0,2 Ω","cmc":"1,6 %"},{"name":"100 kHz až 300 kHz","range":"0,1 Ω až 0,2 Ω","cmc":"2,7 %"},{"name":"300 kHz až 1 MHz","range":"0,1 Ω až 0,2 Ω","cmc":"3,9 %"},{"name":"20 Hz až 50 Hz","range":"0,2 Ω až 0,5 Ω","cmc":"2,6 %"},{"name":"50 Hz až 100 Hz","range":"0,2 Ω až 0,5 Ω","cmc":"1,9 %"},{"name":"100 Hz až 100 kHz","range":"0,2 Ω až 0,5 Ω","cmc":"0,85 %"},{"name":"100 kHz až 300 kHz","range":"0,2 Ω až 0,5 Ω","cmc":"1,5 %"},{"name":"300 kHz až 1 MHz","range":"0,2 Ω až 0,5 Ω","cmc":"2,1 %"},{"name":"20 Hz až 50 Hz","range":"0,5 Ω až 1 Ω","cmc":"1,3 %"},{"name":"50 Hz až 100 Hz","range":"0,5 Ω až 1 Ω","cmc":"0,83 %"},{"name":"100 Hz až 100 kHz","range":"0,5 Ω až 1 Ω","cmc":"0,44 %"},{"name":"100 kHz až 300 kHz","range":"0,5 Ω až 1 Ω","cmc":"0,67 %"},{"name":"300 kHz až 1 MHz","range":"0,5 Ω až 1 Ω","cmc":"0,90 %"},{"name":"20 Hz až 50 Hz","range":"1 Ω až 5 Ω","cmc":"0,78 %"},{"name":"50 Hz až 100 Hz","range":"1 Ω až 5 Ω","cmc":"0,49 %"},{"name":"100 Hz až 100 kHz","range":"1 Ω až 5 Ω","cmc":"0,30 %"},{"name":"100 kHz až 300 kHz","range":"1 Ω až 5 Ω","cmc":"0,41 %"},{"name":"300 kHz až 1 MHz","range":"1 Ω až 5 Ω","cmc":"0,53 %"},{"name":"20 Hz až 50 Hz","range":"5 Ω až 10 Ω","cmc":"0,42 %"},{"name":"50 Hz až 100 Hz","range":"5 Ω až 10 Ω","cmc":"0,23 %"},{"name":"100 Hz až 100 kHz","range":"5 Ω až 10 Ω","cmc":"0,19 %"},{"name":"100 kHz až 300 kHz","range":"5 Ω až 10 Ω","cmc":"0,21 %"},{"name":"300 kHz až 1 MHz","range":"5 Ω až 10 Ω","cmc":"0,23 %"},{"name":"20 Hz až 50 Hz","range":"10 Ω až 15 Ω","cmc":"0,38 %"},{"name":"50 Hz až 100 Hz","range":"10 Ω až 15 Ω","cmc":"0,20 %"},{"name":"100 Hz až 100 kHz","range":"10 Ω až 15 Ω","cmc":"0,18 %"},{"name":"100 kHz až 1 MHz","range":"10 Ω až 15 Ω","cmc":"0,20 %"},{"name":"20 Hz až 50 Hz","range":"15 Ω až 50 Ω","cmc":"0,36 %"},{"name":"50 Hz až 100 Hz","range":"15 Ω až 50 Ω","cmc":"0,18 %"},{"name":"100 Hz až 1 MHz","range":"15 Ω až 50 Ω","cmc":"0,13 %"},{"name":"20 Hz až 50 Hz","range":"50 Ω až 2 kΩ","cmc":"0,34 %"},{"name":"50 Hz až 100 Hz","range":"50 Ω až 2 kΩ","cmc":"0,17 %"},{"name":"100 Hz až 1 MHz","range":"50 Ω až 2 kΩ","cmc":"0,12 %"},{"name":"20 Hz až 50 Hz","range":"2 kΩ až 4 kΩ","cmc":"0,33 %"},{"name":"50 Hz až 100 Hz","range":"2 kΩ až 4 kΩ","cmc":"0,16 %"},{"name":"100 Hz až 300 kHz","range":"2 kΩ až 4 kΩ","cmc":"0,11 %"},{"name":"300 kHz až 1 MHz","range":"2 kΩ až 4 kΩ","cmc":"0,17 %"},{"name":"20 Hz až 50 Hz","range":"4 kΩ až 20 kΩ","cmc":"0,34 %"},{"name":"50 Hz až 100 Hz","range":"4 kΩ až 20 kΩ","cmc":"0,16 %"},{"name":"100 Hz až 100 kHz","range":"4 kΩ až 20 kΩ","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"4 kΩ až 20 kΩ","cmc":"0,17 %"},{"name":"300 kHz až 1 MHz","range":"4 kΩ až 20 kΩ","cmc":"0,19 %"},{"name":"20 Hz až 50 Hz","range":"20 kΩ až 100 kΩ","cmc":"0,37 %"},{"name":"50 Hz až 100 Hz","range":"20 kΩ až 100 kΩ","cmc":"0,19 %"},{"name":"100 Hz až 30 kHz","range":"20 kΩ až 100 kΩ","cmc":"0,13 %"},{"name":"30 kHz až 100 kHz","range":"20 kΩ až 100 kΩ","cmc":"0,17 %"},{"name":"100 kHz až 300 kHz","range":"20 kΩ až 100 kΩ","cmc":"0,20 %"},{"name":"300 kHz až 1 MHz","range":"20 kΩ až 100 kΩ","cmc":"0,28 %"},{"name":"20 Hz až 50 Hz","range":"100 kΩ až 320 kΩ","cmc":"0,46 %"},{"name":"50 Hz až 100 Hz","range":"100 kΩ až 320 kΩ","cmc":"0,26 %"},{"name":"100 Hz až 30 kHz","range":"100 kΩ až 320 kΩ","cmc":"0,15 %"},{"name":"30 kHz až 100 kHz","range":"100 kΩ až 320 kΩ","cmc":"0,20 %"},{"name":"100 kHz až 300 kHz","range":"100 kΩ až 320 kΩ","cmc":"0,28 %"},{"name":"300 kHz až 1 MHz","range":"100 kΩ až 320 kΩ","cmc":"0,55 %"},{"name":"20 Hz až 50 Hz","range":"320 kΩ až 400 kΩ","cmc":"0,49 %"},{"name":"50 Hz až 100 Hz","range":"320 kΩ až 400 kΩ","cmc":"0,28 %"},{"name":"100 Hz až 100 kHz","range":"320 kΩ až 400 kΩ","cmc":"0,21 %"},{"name":"100 kHz až 300 kHz","range":"320 kΩ až 400 kΩ","cmc":"0,31 %"},{"name":"300 kHz až 1 MHz","range":"320 kΩ až 400 kΩ","cmc":"0,65 %"},{"name":"20 Hz až 50 Hz","range":"400 kΩ až 500 kΩ","cmc":"0,53 %"},{"name":"50 Hz až 100 Hz","range":"400 kΩ až 500 kΩ","cmc":"0,31 %"},{"name":"100 Hz až 100 kHz","range":"400 kΩ až 500 kΩ","cmc":"0,22 %"},{"name":"100 kHz až 300 kHz","range":"400 kΩ až 500 kΩ","cmc":"0,34 %"},{"name":"300 kHz až 1 MHz","range":"400 kΩ až 500 kΩ","cmc":"0,77 %"},{"name":"20 Hz až 50 Hz","range":"500 kΩ až 700 kΩ","cmc":"0,61 %"},{"name":"50 Hz až 100 Hz","range":"500 kΩ až 700 kΩ","cmc":"0,37 %"},{"name":"100 Hz až 100 kHz","range":"500 kΩ až 700 kΩ","cmc":"0,25 %"},{"name":"100 kHz až 300 kHz","range":"500 kΩ až 700 kΩ","cmc":"0,42 %"},{"name":"300 kHz až 1 MHz","range":"500 kΩ až 700 kΩ","cmc":"1,1 %"},{"name":"20 Hz až 50 Hz","range":"700 kΩ až 900 kΩ","cmc":"0,69 %"},{"name":"50 Hz až 100 Hz","range":"700 kΩ až 900 kΩ","cmc":"0,43 %"},{"name":"100 Hz až 100 kHz","range":"700 kΩ až 900 kΩ","cmc":"0,27 %"},{"name":"100 kHz až 300 kHz","range":"700 kΩ až 900 kΩ","cmc":"0,49 %"},{"name":"300 kHz až 1 MHz","range":"700 kΩ až 900 kΩ","cmc":"1,3 %"},{"name":"20 Hz až 50 Hz","range":"900 kΩ až 1 MΩ","cmc":"0,73 %"},{"name":"50 Hz až 100 Hz","range":"900 kΩ až 1 MΩ","cmc":"0,46 %"},{"name":"100 Hz až 100 kHz","range":"900 kΩ až 1 MΩ","cmc":"0,28 %"},{"name":"100 kHz až 300 kHz","range":"900 kΩ až 1 MΩ","cmc":"0,53 %"},{"name":"300 kHz až 1 MHz","range":"900 kΩ až 1 MΩ","cmc":"1,4 %"},{"name":"20 Hz až 50 Hz","range":"1 MΩ až 2 MΩ","cmc":"1,2 %"},{"name":"50 Hz až 100 Hz","range":"1 MΩ až 2 MΩ","cmc":"0,75 %"},{"name":"100 Hz až 100 kHz","range":"1 MΩ až 2 MΩ","cmc":"0,41 %"},{"name":"100 kHz až 300 kHz","range":"1 MΩ až 2 MΩ","cmc":"0,90 %"},{"name":"300 kHz až 1 MHz","range":"1 MΩ až 2 MΩ","cmc":"2,7 %"},{"name":"20 Hz až 50 Hz","range":"2 MΩ až 4 MΩ","cmc":"2,0 %"},{"name":"50 Hz až 100 Hz","range":"2 MΩ až 4 MΩ","cmc":"1,4 %"},{"name":"100 Hz až 100 kHz","range":"2 MΩ až 4 MΩ","cmc":"0,65 %"},{"name":"100 kHz až 300 kHz","range":"2 MΩ až 4 MΩ","cmc":"1,7 %"},{"name":"300 kHz až 1 MHz","range":"2 MΩ až 4 MΩ","cmc":"5,1 %"},{"name":"20 Hz až 50 Hz","range":"4 MΩ až 6 MΩ","cmc":"2,8 %"},{"name":"50 Hz až 100 Hz","range":"4 MΩ až 6 MΩ","cmc":"2,0 %"},{"name":"100 Hz až 100 kHz","range":"4 MΩ až 6 MΩ","cmc":"0,90 %"},{"name":"100 kHz až 300 kHz","range":"4 MΩ až 6 MΩ","cmc":"2,4 %"},{"name":"300 kHz až 1 MHz","range":"4 MΩ až 6 MΩ","cmc":"7,6 %"},{"name":"20 Hz až 50 Hz","range":"6 MΩ až 8 MΩ","cmc":"3,6 %"},{"name":"50 Hz až 100 Hz","range":"6 MΩ až 8 MΩ","cmc":"2,6 %"},{"name":"100 Hz až 100 kHz","range":"6 MΩ až 8 MΩ","cmc":"1,2 %"},{"name":"100 kHz až 300 kHz","range":"6 MΩ až 8 MΩ","cmc":"3,2 %"},{"name":"20 Hz až 50 Hz","range":"8 MΩ až 10 MΩ","cmc":"4,4 %"},{"name":"50 Hz až 100 Hz","range":"8 MΩ až 10 MΩ","cmc":"3,2 %"},{"name":"100 Hz až 100 kHz","range":"8 MΩ až 10 MΩ","cmc":"1,4 %"},{"name":"100 kHz až 300 kHz","range":"8 MΩ až 10 MΩ","cmc":"3,9 %"},{"name":"20 Hz až 50 Hz","range":"10 MΩ až 15 MΩ","cmc":"6,4 %"},{"name":"50 Hz až 100 Hz","range":"10 MΩ až 15 MΩ","cmc":"4,8 %"},{"name":"100 Hz až 100 kHz","range":"10 MΩ až 15 MΩ","cmc":"2,2 %"},{"name":"100 kHz až 300 kHz","range":"10 MΩ až 15 MΩ","cmc":"5,8 %"},{"name":"20 Hz až 50 Hz","range":"15 MΩ až 20 MΩ","cmc":"8,4 %"},{"name":"50 Hz až 100 Hz","range":"15 MΩ až 20 MΩ","cmc":"6,3 %"},{"name":"100 Hz až 100 kHz","range":"15 MΩ až 20 MΩ","cmc":"2,8 %"},{"name":"100 kHz až 300 kHz","range":"15 MΩ až 20 MΩ","cmc":"7,6 %"},{"name":"100 Hz až 1 kHz","range":"20 MΩ až 25 MΩ","cmc":"3,5 %"},{"name":"1 kHz až 100 kHz","range":"20 MΩ až 25 MΩ","cmc":"3,3 %"},{"name":"100 Hz až 1 kHz","range":"25 MΩ až 30 MΩ","cmc":"4,1 %"},{"name":"1 kHz až 100 kHz","range":"25 MΩ až 30 MΩ","cmc":"3,9 %"}],"technique":"Pomiar bezpośredni miernikiem LCR","technique_en":"Direct measurement by a LCR meter","technique_zh":"用 LCR 表直接测量","technique_cs":"Přímé měření LCR měřidlem","techniques":["Pomiar bezpośredni miernikiem LCR"],"techniques_en":["Direct measurement by a LCR meter"],"techniques_zh":["用 LCR 表直接测量"],"techniques_cs":["Přímé měření LCR měřidlem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n100 Hz do 100 kHz od 50 mΩ do 0,1 Ω CMC 3,1 %\n100 kHz do 300 kHz od 50 mΩ do 0,1 Ω CMC 5,3 %\n20 Hz do 50 Hz od 0,1 Ω do 0,2 Ω CMC 4,9 %\n50 Hz do 100 Hz od 0,1 Ω do 0,2 Ω CMC 3,5 %\n100 Hz do 100 kHz od 0,1 Ω do 0,2 Ω CMC 1,6 %\n100 kHz do 300 kHz od 0,1 Ω do 0,2 Ω CMC 2,7 %\n300 kHz do 1 MHz od 0,1 Ω do 0,2 Ω CMC 3,9 %\n20 Hz do 50 Hz od 0,2 Ω do 0,5 Ω CMC 2,6 %\n50 Hz do 100 Hz od 0,2 Ω do 0,5 Ω CMC 1,9 %\n100 Hz do 100 kHz od 0,2 Ω do 0,5 Ω CMC 0,85 %\n100 kHz do 300 kHz od 0,2 Ω do 0,5 Ω CMC 1,5 %\n300 kHz do 1 MHz od 0,2 Ω do 0,5 Ω CMC 2,1 %\n20 Hz do 50 Hz od 0,5 Ω do 1 Ω CMC 1,3 %\n50 Hz do 100 Hz od 0,5 Ω do 1 Ω CMC 0,83 %\n100 Hz do 100 kHz od 0,5 Ω do 1 Ω CMC 0,44 %\n100 kHz do 300 kHz od 0,5 Ω do 1 Ω CMC 0,67 %\n300 kHz do 1 MHz od 0,5 Ω do 1 Ω CMC 0,90 %\n20 Hz do 50 Hz od 1 Ω do 5 Ω CMC 0,78 %\n50 Hz do 100 Hz od 1 Ω do 5 Ω CMC 0,49 %\n100 Hz do 100 kHz od 1 Ω do 5 Ω CMC 0,30 %\n100 kHz do 300 kHz od 1 Ω do 5 Ω CMC 0,41 %\n300 kHz do 1 MHz od 1 Ω do 5 Ω CMC 0,53 %\n20 Hz do 50 Hz od 5 Ω do 10 Ω CMC 0,42 %\n50 Hz do 100 Hz od 5 Ω do 10 Ω CMC 0,23 %\n100 Hz do 100 kHz od 5 Ω do 10 Ω CMC 0,19 %\n100 kHz do 300 kHz od 5 Ω do 10 Ω CMC 0,21 %\n300 kHz do 1 MHz od 5 Ω do 10 Ω CMC 0,23 %\n20 Hz do 50 Hz od 10 Ω do 15 Ω CMC 0,38 %\n50 Hz do 100 Hz od 10 Ω do 15 Ω CMC 0,20 %\n100 Hz do 100 kHz od 10 Ω do 15 Ω CMC 0,18 %\n100 kHz do 1 MHz od 10 Ω do 15 Ω CMC 0,20 %\n20 Hz do 50 Hz od 15 Ω do 50 Ω CMC 0,36 %\n50 Hz do 100 Hz od 15 Ω do 50 Ω CMC 0,18 %\n100 Hz do 1 MHz od 15 Ω do 50 Ω CMC 0,13 %\n20 Hz do 50 Hz od 50 Ω do 2 kΩ CMC 0,34 %\n50 Hz do 100 Hz od 50 Ω do 2 kΩ CMC 0,17 %\n100 Hz do 1 MHz od 50 Ω do 2 kΩ CMC 0,12 %\n20 Hz do 50 Hz od 2 kΩ do 4 kΩ CMC 0,33 %\n50 Hz do 100 Hz od 2 kΩ do 4 kΩ CMC 0,16 %\n100 Hz do 300 kHz od 2 kΩ do 4 kΩ CMC 0,11 %\n300 kHz do 1 MHz od 2 kΩ do 4 kΩ CMC 0,17 %\n20 Hz do 50 Hz od 4 kΩ do 20 kΩ CMC 0,34 %\n50 Hz do 100 Hz od 4 kΩ do 20 kΩ CMC 0,16 %\n100 Hz do 100 kHz od 4 kΩ do 20 kΩ CMC 0,11 %\n100 kHz do 300 kHz od 4 kΩ do 20 kΩ CMC 0,17 %\n300 kHz do 1 MHz od 4 kΩ do 20 kΩ CMC 0,19 %\n20 Hz do 50 Hz od 20 kΩ do 100 kΩ CMC 0,37 %\n50 Hz do 100 Hz od 20 kΩ do 100 kΩ CMC 0,19 %\n100 Hz do 30 kHz od 20 kΩ do 100 kΩ CMC 0,13 %\n30 kHz do 100 kHz od 20 kΩ do 100 kΩ CMC 0,17 %\n100 kHz do 300 kHz od 20 kΩ do 100 kΩ CMC 0,20 %\n300 kHz do 1 MHz od 20 kΩ do 100 kΩ CMC 0,28 %\n20 Hz do 50 Hz od 100 kΩ do 320 kΩ CMC 0,46 %\n50 Hz do 100 Hz od 100 kΩ do 320 kΩ CMC 0,26 %\n100 Hz do 30 kHz od 100 kΩ do 320 kΩ CMC 0,15 %\n30 kHz do 100 kHz od 100 kΩ do 320 kΩ CMC 0,20 %\n100 kHz do 300 kHz od 100 kΩ do 320 kΩ CMC 0,28 %\n300 kHz do 1 MHz od 100 kΩ do 320 kΩ CMC 0,55 %\n20 Hz do 50 Hz od 320 kΩ do 400 kΩ CMC 0,49 %\n50 Hz do 100 Hz od 320 kΩ do 400 kΩ CMC 0,28 %\n100 Hz do 100 kHz od 320 kΩ do 400 kΩ CMC 0,21 %\n100 kHz do 300 kHz od 320 kΩ do 400 kΩ CMC 0,31 %\n300 kHz do 1 MHz od 320 kΩ do 400 kΩ CMC 0,65 %\n20 Hz do 50 Hz od 400 kΩ do 500 kΩ CMC 0,53 %\n50 Hz do 100 Hz od 400 kΩ do 500 kΩ CMC 0,31 %\n100 Hz do 100 kHz od 400 kΩ do 500 kΩ CMC 0,22 %\n100 kHz do 300 kHz od 400 kΩ do 500 kΩ CMC 0,34 %\n300 kHz do 1 MHz od 400 kΩ do 500 kΩ CMC 0,77 %\n20 Hz do 50 Hz od 500 kΩ do 700 kΩ CMC 0,61 %\n50 Hz do 100 Hz od 500 kΩ do 700 kΩ CMC 0,37 %\n100 Hz do 100 kHz od 500 kΩ do 700 kΩ CMC 0,25 %\n100 kHz do 300 kHz od 500 kΩ do 700 kΩ CMC 0,42 %\n300 kHz do 1 MHz od 500 kΩ do 700 kΩ CMC 1,1 %\n20 Hz do 50 Hz od 700 kΩ do 900 kΩ CMC 0,69 %\n50 Hz do 100 Hz od 700 kΩ do 900 kΩ CMC 0,43 %\n100 Hz do 100 kHz od 700 kΩ do 900 kΩ CMC 0,27 %\n100 kHz do 300 kHz od 700 kΩ do 900 kΩ CMC 0,49 %\n300 kHz do 1 MHz od 700 kΩ do 900 kΩ CMC 1,3 %\n20 Hz do 50 Hz od 900 kΩ do 1 MΩ CMC 0,73 %\n50 Hz do 100 Hz od 900 kΩ do 1 MΩ CMC 0,46 %\n100 Hz do 100 kHz od 900 kΩ do 1 MΩ CMC 0,28 %\n100 kHz do 300 kHz od 900 kΩ do 1 MΩ CMC 0,53 %\n300 kHz do 1 MHz od 900 kΩ do 1 MΩ CMC 1,4 %\n20 Hz do 50 Hz od 1 MΩ do 2 MΩ CMC 1,2 %\n50 Hz do 100 Hz od 1 MΩ do 2 MΩ CMC 0,75 %\n100 Hz do 100 kHz od 1 MΩ do 2 MΩ CMC 0,41 %\n100 kHz do 300 kHz od 1 MΩ do 2 MΩ CMC 0,90 %\n300 kHz do 1 MHz od 1 MΩ do 2 MΩ CMC 2,7 %\n20 Hz do 50 Hz od 2 MΩ do 4 MΩ CMC 2,0 %\n50 Hz do 100 Hz od 2 MΩ do 4 MΩ CMC 1,4 %\n100 Hz do 100 kHz od 2 MΩ do 4 MΩ CMC 0,65 %\n100 kHz do 300 kHz od 2 MΩ do 4 MΩ CMC 1,7 %\n300 kHz do 1 MHz od 2 MΩ do 4 MΩ CMC 5,1 %\n20 Hz do 50 Hz od 4 MΩ do 6 MΩ CMC 2,8 %\n50 Hz do 100 Hz od 4 MΩ do 6 MΩ CMC 2,0 %\n100 Hz do 100 kHz od 4 MΩ do 6 MΩ CMC 0,90 %\n100 kHz do 300 kHz od 4 MΩ do 6 MΩ CMC 2,4 %\n300 kHz do 1 MHz od 4 MΩ do 6 MΩ CMC 7,6 %\n20 Hz do 50 Hz od 6 MΩ do 8 MΩ CMC 3,6 %\n50 Hz do 100 Hz od 6 MΩ do 8 MΩ CMC 2,6 %\n100 Hz do 100 kHz od 6 MΩ do 8 MΩ CMC 1,2 %\n100 kHz do 300 kHz od 6 MΩ do 8 MΩ CMC 3,2 %\n20 Hz do 50 Hz od 8 MΩ do 10 MΩ CMC 4,4 %\n50 Hz do 100 Hz od 8 MΩ do 10 MΩ CMC 3,2 %\n100 Hz do 100 kHz od 8 MΩ do 10 MΩ CMC 1,4 %\n100 kHz do 300 kHz od 8 MΩ do 10 MΩ CMC 3,9 %\n20 Hz do 50 Hz od 10 MΩ do 15 MΩ CMC 6,4 %\n50 Hz do 100 Hz od 10 MΩ do 15 MΩ CMC 4,8 %\n100 Hz do 100 kHz od 10 MΩ do 15 MΩ CMC 2,2 %\n100 kHz do 300 kHz od 10 MΩ do 15 MΩ CMC 5,8 %\n20 Hz do 50 Hz od 15 MΩ do 20 MΩ CMC 8,4 %\n50 Hz do 100 Hz od 15 MΩ do 20 MΩ CMC 6,3 %\n100 Hz do 100 kHz od 15 MΩ do 20 MΩ CMC 2,8 %\n100 kHz do 300 kHz od 15 MΩ do 20 MΩ CMC 7,6 %\n100 Hz do 1 kHz od 20 MΩ do 25 MΩ CMC 3,5 %\n1 kHz do 100 kHz od 20 MΩ do 25 MΩ CMC 3,3 %\n100 Hz do 1 kHz od 25 MΩ do 30 MΩ CMC 4,1 %\n1 kHz do 100 kHz od 25 MΩ do 30 MΩ CMC 3,9 %\nPomiar bezpośredni miernikiem LCR","reference":"TP6, TP24","norm_bases":["TP6","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie przemiennym / Wzorce rezystancji przy prądzie przemiennym dla częstotliwości od 20 Hz do 1 MHz Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem LCR 100 Hz do 100 kHz od 50 mΩ do 0,1 Ω CMC 3,1 % 100 kHz do 300 kHz od 50 mΩ do 0,1 Ω CMC 5,3 % 20 Hz do 50 Hz od 0,1 Ω do 0,2 Ω CMC 4,9 % 50 Hz do 100 Hz od 0,1 Ω do 0,2 Ω CMC 3,5 % 100 Hz do 100 kHz od 0,1 Ω do 0,2 Ω CMC 1,6 % 100 kHz do 300 kHz od 0,1 Ω do 0,2 Ω CMC 2,7 % 300 kHz do 1 MHz od 0,1 Ω do 0,2 Ω CMC 3,9 % 20 Hz do 50 Hz od 0,2 Ω do 0,5 Ω CMC 2,6 % 50 Hz do 100 Hz od 0,2 Ω do 0,5 Ω CMC 1,9 % 100 Hz do 100 kHz od 0,2 Ω do 0,5 Ω CMC 0,85 % 100 kHz do 300 kHz od 0,2 Ω do 0,5 Ω CMC 1,5 % 300 kHz do 1 MHz od 0,2 Ω do 0,5 Ω CMC 2,1 % 20 Hz do 50 Hz od 0,5 Ω do 1 Ω CMC 1,3 % 50 Hz do 100 Hz od 0,5 Ω do 1 Ω CMC 0,83 % 100 Hz do 100 kHz od 0,5 Ω do 1 Ω CMC 0,44 % 100 kHz do 300 kHz od 0,5 Ω do 1 Ω CMC 0,67 % 300 kHz do 1 MHz od 0,5 Ω do 1 Ω CMC 0,90 % 20 Hz do 50 Hz od 1 Ω do 5 Ω CMC 0,78 % 50 Hz do 100 Hz od 1 Ω do 5 Ω CMC 0,49 % 100 Hz do 100 kHz od 1 Ω do 5 Ω CMC 0,30 % 100 kHz do 300 kHz od 1 Ω do 5 Ω CMC 0,41 % 300 kHz do 1 MHz od 1 Ω do 5 Ω CMC 0,53 % 20 Hz do 50 Hz od 5 Ω do 10 Ω CMC 0,42 % 50 Hz do 100 Hz od 5 Ω do 10 Ω CMC 0,23 % 100 Hz do 100 kHz od 5 Ω do 10 Ω CMC 0,19 % 100 kHz do 300 kHz od 5 Ω do 10 Ω CMC 0,21 % 300 kHz do 1 MHz od 5 Ω do 10 Ω CMC 0,23 % 20 Hz do 50 Hz od 10 Ω do 15 Ω CMC 0,38 % 50 Hz do 100 Hz od 10 Ω do 15 Ω CMC 0,20 % 100 Hz do 100 kHz od 10 Ω do 15 Ω CMC 0,18 % 100 kHz do 1 MHz od 10 Ω do 15 Ω CMC 0,20 % 20 Hz do 50 Hz od 15 Ω do 50 Ω CMC 0,36 % 50 Hz do 100 Hz od 15 Ω do 50 Ω CMC 0,18 % 100 Hz do 1 MHz od 15 Ω do 50 Ω CMC 0,13 % 20 Hz do 50 Hz od 50 Ω do 2 kΩ CMC 0,34 % 50 Hz do 100 Hz od 50 Ω do 2 kΩ CMC 0,17 % 100 Hz do 1 MHz od 50 Ω do 2 kΩ CMC 0,12 % 20 Hz do 50 Hz od 2 kΩ do 4 kΩ CMC 0,33 % 50 Hz do 100 Hz od 2 kΩ do 4 kΩ CMC 0,16 % 100 Hz do 300 kHz od 2 kΩ do 4 kΩ CMC 0,11 % 300 kHz do 1 MHz od 2 kΩ do 4 kΩ CMC 0,17 % 20 Hz do 50 Hz od 4 kΩ do 20 kΩ CMC 0,34 % 50 Hz do 100 Hz od 4 kΩ do 20 kΩ CMC 0,16 % 100 Hz do 100 kHz od 4 kΩ do 20 kΩ CMC 0,11 % 100 kHz do 300 kHz od 4 kΩ do 20 kΩ CMC 0,17 % 300 kHz do 1 MHz od 4 kΩ do 20 kΩ CMC 0,19 % 20 Hz do 50 Hz od 20 kΩ do 100 kΩ CMC 0,37 % 50 Hz do 100 Hz od 20 kΩ do 100 kΩ CMC 0,19 % 100 Hz do 30 kHz od 20 kΩ do 100 kΩ CMC 0,13 % 30 kHz do 100 kHz od 20 kΩ do 100 kΩ CMC 0,17 % 100 kHz do 300 kHz od 20 kΩ do 100 kΩ CMC 0,20 % 300 kHz do 1 MHz od 20 kΩ do 100 kΩ CMC 0,28 % 20 Hz do 50 Hz od 100 kΩ do 320 kΩ CMC 0,46 % 50 Hz do 100 Hz od 100 kΩ do 320 kΩ CMC 0,26 % 100 Hz do 30 kHz od 100 kΩ do 320 kΩ CMC 0,15 % 30 kHz do 100 kHz od 100 kΩ do 320 kΩ CMC 0,20 % 100 kHz do 300 kHz od 100 kΩ do 320 kΩ CMC 0,28 % 300 kHz do 1 MHz od 100 kΩ do 320 kΩ CMC 0,55 % 20 Hz do 50 Hz od 320 kΩ do 400 kΩ CMC 0,49 % 50 Hz do 100 Hz od 320 kΩ do 400 kΩ CMC 0,28 % 100 Hz do 100 kHz od 320 kΩ do 400 kΩ CMC 0,21 % 100 kHz do 300 kHz od 320 kΩ do 400 kΩ CMC 0,31 % 300 kHz do 1 MHz od 320 kΩ do 400 kΩ CMC 0,65 % 20 Hz do 50 Hz od 400 kΩ do 500 kΩ CMC 0,53 % 50 Hz do 100 Hz od 400 kΩ do 500 kΩ CMC 0,31 % 100 Hz do 100 kHz od 400 kΩ do 500 kΩ CMC 0,22 % 100 kHz do 300 kHz od 400 kΩ do 500 kΩ CMC 0,34 % 300 kHz do 1 MHz od 400 kΩ do 500 kΩ CMC 0,77 % 20 Hz do 50 Hz od 500 kΩ do 700 kΩ CMC 0,61 % 50 Hz do 100 Hz od 500 kΩ do 700 kΩ CMC 0,37 % 100 Hz do 100 kHz od 500 kΩ do 700 kΩ CMC 0,25 % 100 kHz do 300 kHz od 500 kΩ do 700 kΩ CMC 0,42 % 300 kHz do 1 MHz od 500 kΩ do 700 kΩ CMC 1,1 % 20 Hz do 50 Hz od 700 kΩ do 900 kΩ CMC 0,69 % 50 Hz do 100 Hz od 700 kΩ do 900 kΩ CMC 0,43 % 100 Hz do 100 kHz od 700 kΩ do 900 kΩ CMC 0,27 % 100 kHz do 300 kHz od 700 kΩ do 900 kΩ CMC 0,49 % 300 kHz do 1 MHz od 700 kΩ do 900 kΩ CMC 1,3 % 20 Hz do 50 Hz od 900 kΩ do 1 MΩ CMC 0,73 % 50 Hz do 100 Hz od 900 kΩ do 1 MΩ CMC 0,46 % 100 Hz do 100 kHz od 900 kΩ do 1 MΩ CMC 0,28 % 100 kHz do 300 kHz od 900 kΩ do 1 MΩ CMC 0,53 % 300 kHz do 1 MHz od 900 kΩ do 1 MΩ CMC 1,4 % 20 Hz do 50 Hz od 1 MΩ do 2 MΩ CMC 1,2 % 50 Hz do 100 Hz od 1 MΩ do 2 MΩ CMC 0,75 % 100 Hz do 100 kHz od 1 MΩ do 2 MΩ CMC 0,41 % 100 kHz do 300 kHz od 1 MΩ do 2 MΩ CMC 0,90 % 300 kHz do 1 MHz od 1 MΩ do 2 MΩ CMC 2,7 % 20 Hz do 50 Hz od 2 MΩ do 4 MΩ CMC 2,0 % 50 Hz do 100 Hz od 2 MΩ do 4 MΩ CMC 1,4 % 100 Hz do 100 kHz od 2 MΩ do 4 MΩ CMC 0,65 % 100 kHz do 300 kHz od 2 MΩ do 4 MΩ CMC 1,7 % 300 kHz do 1 MHz od 2 MΩ do 4 MΩ CMC 5,1 % 20 Hz do 50 Hz od 4 MΩ do 6 MΩ CMC 2,8 % 50 Hz do 100 Hz od 4 MΩ do 6 MΩ CMC 2,0 % 100 Hz do 100 kHz od 4 MΩ do 6 MΩ CMC 0,90 % 100 kHz do 300 kHz od 4 MΩ do 6 MΩ CMC 2,4 % 300 kHz do 1 MHz od 4 MΩ do 6 MΩ CMC 7,6 % 20 Hz do 50 Hz od 6 MΩ do 8 MΩ CMC 3,6 % 50 Hz do 100 Hz od 6 MΩ do 8 MΩ CMC 2,6 % 100 Hz do 100 kHz od 6 MΩ do 8 MΩ CMC 1,2 % 100 kHz do 300 kHz od 6 MΩ do 8 MΩ CMC 3,2 % 20 Hz do 50 Hz od 8 MΩ do 10 MΩ CMC 4,4 % 50 Hz do 100 Hz od 8 MΩ do 10 MΩ CMC 3,2 % 100 Hz do 100 kHz od 8 MΩ do 10 MΩ CMC 1,4 % 100 kHz do 300 kHz od 8 MΩ do 10 MΩ CMC 3,9 % 20 Hz do 50 Hz od 10 MΩ do 15 MΩ CMC 6,4 % 50 Hz do 100 Hz od 10 MΩ do 15 MΩ CMC 4,8 % 100 Hz do 100 kHz od 10 MΩ do 15 MΩ CMC 2,2 % 100 kHz do 300 kHz od 10 MΩ do 15 MΩ CMC 5,8 % 20 Hz do 50 Hz od 15 MΩ do 20 MΩ CMC 8,4 % 50 Hz do 100 Hz od 15 MΩ do 20 MΩ CMC 6,3 % 100 Hz do 100 kHz od 15 MΩ do 20 MΩ CMC 2,8 % 100 kHz do 300 kHz od 15 MΩ do 20 MΩ CMC 7,6 % 100 Hz do 1 kHz od 20 MΩ do 25 MΩ CMC 3,5 % 1 kHz do 100 kHz od 20 MΩ do 25 MΩ CMC 3,3 % 100 Hz do 1 kHz od 25 MΩ do 30 MΩ CMC 4,1 % 1 kHz do 100 kHz od 25 MΩ do 30 MΩ CMC 3,9 % Střídavý odpor / Etalony střídavého odporu pro kmitočty 20 Hz až 1 MHz Kalibrace – elektrické veličiny Přímé měření LCR měřidlem 100 Hz až 100 kHz 50 mΩ až 0,1 Ω CMC 3,1 % 100 kHz až 300 kHz 50 mΩ až 0,1 Ω CMC 5,3 % 20 Hz až 50 Hz 0,1 Ω až 0,2 Ω CMC 4,9 % 50 Hz až 100 Hz 0,1 Ω až 0,2 Ω CMC 3,5 % 100 Hz až 100 kHz 0,1 Ω až 0,2 Ω CMC 1,6 % 100 kHz až 300 kHz 0,1 Ω až 0,2 Ω CMC 2,7 % 300 kHz až 1 MHz 0,1 Ω až 0,2 Ω CMC 3,9 % 20 Hz až 50 Hz 0,2 Ω až 0,5 Ω CMC 2,6 % 50 Hz až 100 Hz 0,2 Ω až 0,5 Ω CMC 1,9 % 100 Hz až 100 kHz 0,2 Ω až 0,5 Ω CMC 0,85 % 100 kHz až 300 kHz 0,2 Ω až 0,5 Ω CMC 1,5 % 300 kHz až 1 MHz 0,2 Ω až 0,5 Ω CMC 2,1 % 20 Hz až 50 Hz 0,5 Ω až 1 Ω CMC 1,3 % 50 Hz až 100 Hz 0,5 Ω až 1 Ω CMC 0,83 % 100 Hz až 100 kHz 0,5 Ω až 1 Ω CMC 0,44 % 100 kHz až 300 kHz 0,5 Ω až 1 Ω CMC 0,67 % 300 kHz až 1 MHz 0,5 Ω až 1 Ω CMC 0,90 % 20 Hz až 50 Hz 1 Ω až 5 Ω CMC 0,78 % 50 Hz až 100 Hz 1 Ω až 5 Ω CMC 0,49 % 100 Hz až 100 kHz 1 Ω až 5 Ω CMC 0,30 % 100 kHz až 300 kHz 1 Ω až 5 Ω CMC 0,41 % 300 kHz až 1 MHz 1 Ω až 5 Ω CMC 0,53 % 20 Hz až 50 Hz 5 Ω až 10 Ω CMC 0,42 % 50 Hz až 100 Hz 5 Ω až 10 Ω CMC 0,23 % 100 Hz až 100 kHz 5 Ω až 10 Ω CMC 0,19 % 100 kHz až 300 kHz 5 Ω až 10 Ω CMC 0,21 % 300 kHz až 1 MHz 5 Ω až 10 Ω CMC 0,23 % 20 Hz až 50 Hz 10 Ω až 15 Ω CMC 0,38 % 50 Hz až 100 Hz 10 Ω až 15 Ω CMC 0,20 % 100 Hz až 100 kHz 10 Ω až 15 Ω CMC 0,18 % 100 kHz až 1 MHz 10 Ω až 15 Ω CMC 0,20 % 20 Hz až 50 Hz 15 Ω až 50 Ω CMC 0,36 % 50 Hz až 100 Hz 15 Ω až 50 Ω CMC 0,18 % 100 Hz až 1 MHz 15 Ω až 50 Ω CMC 0,13 % 20 Hz až 50 Hz 50 Ω až 2 kΩ CMC 0,34 % 50 Hz až 100 Hz 50 Ω až 2 kΩ CMC 0,17 % 100 Hz až 1 MHz 50 Ω až 2 kΩ CMC 0,12 % 20 Hz až 50 Hz 2 kΩ až 4 kΩ CMC 0,33 % 50 Hz až 100 Hz 2 kΩ až 4 kΩ CMC 0,16 % 100 Hz až 300 kHz 2 kΩ až 4 kΩ CMC 0,11 % 300 kHz až 1 MHz 2 kΩ až 4 kΩ CMC 0,17 % 20 Hz až 50 Hz 4 kΩ až 20 kΩ CMC 0,34 % 50 Hz až 100 Hz 4 kΩ až 20 kΩ CMC 0,16 % 100 Hz až 100 kHz 4 kΩ až 20 kΩ CMC 0,11 % 100 kHz až 300 kHz 4 kΩ až 20 kΩ CMC 0,17 % 300 kHz až 1 MHz 4 kΩ až 20 kΩ CMC 0,19 % 20 Hz až 50 Hz 20 kΩ až 100 kΩ CMC 0,37 % 50 Hz až 100 Hz 20 kΩ až 100 kΩ CMC 0,19 % 100 Hz až 30 kHz 20 kΩ až 100 kΩ CMC 0,13 % 30 kHz až 100 kHz 20 kΩ až 100 kΩ CMC 0,17 % 100 kHz až 300 kHz 20 kΩ až 100 kΩ CMC 0,20 % 300 kHz až 1 MHz 20 kΩ až 100 kΩ CMC 0,28 % 20 Hz až 50 Hz 100 kΩ až 320 kΩ CMC 0,46 % 50 Hz až 100 Hz 100 kΩ až 320 kΩ CMC 0,26 % 100 Hz až 30 kHz 100 kΩ až 320 kΩ CMC 0,15 % 30 kHz až 100 kHz 100 kΩ až 320 kΩ CMC 0,20 % 100 kHz až 300 kHz 100 kΩ až 320 kΩ CMC 0,28 % 300 kHz až 1 MHz 100 kΩ až 320 kΩ CMC 0,55 % 20 Hz až 50 Hz 320 kΩ až 400 kΩ CMC 0,49 % 50 Hz až 100 Hz 320 kΩ až 400 kΩ CMC 0,28 % 100 Hz až 100 kHz 320 kΩ až 400 kΩ CMC 0,21 % 100 kHz až 300 kHz 320 kΩ až 400 kΩ CMC 0,31 % 300 kHz až 1 MHz 320 kΩ až 400 kΩ CMC 0,65 % 20 Hz až 50 Hz 400 kΩ až 500 kΩ CMC 0,53 % 50 Hz až 100 Hz 400 kΩ až 500 kΩ CMC 0,31 % 100 Hz až 100 kHz 400 kΩ až 500 kΩ CMC 0,22 % 100 kHz až 300 kHz 400 kΩ až 500 kΩ CMC 0,34 % 300 kHz až 1 MHz 400 kΩ až 500 kΩ CMC 0,77 % 20 Hz až 50 Hz 500 kΩ až 700 kΩ CMC 0,61 % 50 Hz až 100 Hz 500 kΩ až 700 kΩ CMC 0,37 % 100 Hz až 100 kHz 500 kΩ až 700 kΩ CMC 0,25 % 100 kHz až 300 kHz 500 kΩ až 700 kΩ CMC 0,42 % 300 kHz až 1 MHz 500 kΩ až 700 kΩ CMC 1,1 % 20 Hz až 50 Hz 700 kΩ až 900 kΩ CMC 0,69 % 50 Hz až 100 Hz 700 kΩ až 900 kΩ CMC 0,43 % 100 Hz až 100 kHz 700 kΩ až 900 kΩ CMC 0,27 % 100 kHz až 300 kHz 700 kΩ až 900 kΩ CMC 0,49 % 300 kHz až 1 MHz 700 kΩ až 900 kΩ CMC 1,3 % 20 Hz až 50 Hz 900 kΩ až 1 MΩ CMC 0,73 % 50 Hz až 100 Hz 900 kΩ až 1 MΩ CMC 0,46 % 100 Hz až 100 kHz 900 kΩ až 1 MΩ CMC 0,28 % 100 kHz až 300 kHz 900 kΩ až 1 MΩ CMC 0,53 % 300 kHz až 1 MHz 900 kΩ až 1 MΩ CMC 1,4 % 20 Hz až 50 Hz 1 MΩ až 2 MΩ CMC 1,2 % 50 Hz až 100 Hz 1 MΩ až 2 MΩ CMC 0,75 % 100 Hz až 100 kHz 1 MΩ až 2 MΩ CMC 0,41 % 100 kHz až 300 kHz 1 MΩ až 2 MΩ CMC 0,90 % 300 kHz až 1 MHz 1 MΩ až 2 MΩ CMC 2,7 % 20 Hz až 50 Hz 2 MΩ až 4 MΩ CMC 2,0 % 50 Hz až 100 Hz 2 MΩ až 4 MΩ CMC 1,4 % 100 Hz až 100 kHz 2 MΩ až 4 MΩ CMC 0,65 % 100 kHz až 300 kHz 2 MΩ až 4 MΩ CMC 1,7 % 300 kHz až 1 MHz 2 MΩ až 4 MΩ CMC 5,1 % 20 Hz až 50 Hz 4 MΩ až 6 MΩ CMC 2,8 % 50 Hz až 100 Hz 4 MΩ až 6 MΩ CMC 2,0 % 100 Hz až 100 kHz 4 MΩ až 6 MΩ CMC 0,90 % 100 kHz až 300 kHz 4 MΩ až 6 MΩ CMC 2,4 % 300 kHz až 1 MHz 4 MΩ až 6 MΩ CMC 7,6 % 20 Hz až 50 Hz 6 MΩ až 8 MΩ CMC 3,6 % 50 Hz až 100 Hz 6 MΩ až 8 MΩ CMC 2,6 % 100 Hz až 100 kHz 6 MΩ až 8 MΩ CMC 1,2 % 100 kHz až 300 kHz 6 MΩ až 8 MΩ CMC 3,2 % 20 Hz až 50 Hz 8 MΩ až 10 MΩ CMC 4,4 % 50 Hz až 100 Hz 8 MΩ až 10 MΩ CMC 3,2 % 100 Hz až 100 kHz 8 MΩ až 10 MΩ CMC 1,4 % 100 kHz až 300 kHz 8 MΩ až 10 MΩ CMC 3,9 % 20 Hz až 50 Hz 10 MΩ až 15 MΩ CMC 6,4 % 50 Hz až 100 Hz 10 MΩ až 15 MΩ CMC 4,8 % 100 Hz až 100 kHz 10 MΩ až 15 MΩ CMC 2,2 % 100 kHz až 300 kHz 10 MΩ až 15 MΩ CMC 5,8 % 20 Hz až 50 Hz 15 MΩ až 20 MΩ CMC 8,4 % 50 Hz až 100 Hz 15 MΩ až 20 MΩ CMC 6,3 % 100 Hz až 100 kHz 15 MΩ až 20 MΩ CMC 2,8 % 100 kHz až 300 kHz 15 MΩ až 20 MΩ CMC 7,6 % 100 Hz až 1 kHz 20 MΩ až 25 MΩ CMC 3,5 % 1 kHz až 100 kHz 20 MΩ až 25 MΩ CMC 3,3 % 100 Hz až 1 kHz 25 MΩ až 30 MΩ CMC 4,1 % 1 kHz až 100 kHz 25 MΩ až 30 MΩ CMC 3,9 % TP6, TP24 Rezystancja przy pradzie przemiennym / Wzorce rezystancji przy pradzie przemiennym dla czestotliwosci od 20 Hz do 1 MHz Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem LCR 100 Hz do 100 kHz od 50 mΩ do 0,1 Ω CMC 3,1 % 100 kHz do 300 kHz od 50 mΩ do 0,1 Ω CMC 5,3 % 20 Hz do 50 Hz od 0,1 Ω do 0,2 Ω CMC 4,9 % 50 Hz do 100 Hz od 0,1 Ω do 0,2 Ω CMC 3,5 % 100 Hz do 100 kHz od 0,1 Ω do 0,2 Ω CMC 1,6 % 100 kHz do 300 kHz od 0,1 Ω do 0,2 Ω CMC 2,7 % 300 kHz do 1 MHz od 0,1 Ω do 0,2 Ω CMC 3,9 % 20 Hz do 50 Hz od 0,2 Ω do 0,5 Ω CMC 2,6 % 50 Hz do 100 Hz od 0,2 Ω do 0,5 Ω CMC 1,9 % 100 Hz do 100 kHz od 0,2 Ω do 0,5 Ω CMC 0,85 % 100 kHz do 300 kHz od 0,2 Ω do 0,5 Ω CMC 1,5 % 300 kHz do 1 MHz od 0,2 Ω do 0,5 Ω CMC 2,1 % 20 Hz do 50 Hz od 0,5 Ω do 1 Ω CMC 1,3 % 50 Hz do 100 Hz od 0,5 Ω do 1 Ω CMC 0,83 % 100 Hz do 100 kHz od 0,5 Ω do 1 Ω CMC 0,44 % 100 kHz do 300 kHz od 0,5 Ω do 1 Ω CMC 0,67 % 300 kHz do 1 MHz od 0,5 Ω do 1 Ω CMC 0,90 % 20 Hz do 50 Hz od 1 Ω do 5 Ω CMC 0,78 % 50 Hz do 100 Hz od 1 Ω do 5 Ω CMC 0,49 % 100 Hz do 100 kHz od 1 Ω do 5 Ω CMC 0,30 % 100 kHz do 300 kHz od 1 Ω do 5 Ω CMC 0,41 % 300 kHz do 1 MHz od 1 Ω do 5 Ω CMC 0,53 % 20 Hz do 50 Hz od 5 Ω do 10 Ω CMC 0,42 % 50 Hz do 100 Hz od 5 Ω do 10 Ω CMC 0,23 % 100 Hz do 100 kHz od 5 Ω do 10 Ω CMC 0,19 % 100 kHz do 300 kHz od 5 Ω do 10 Ω CMC 0,21 % 300 kHz do 1 MHz od 5 Ω do 10 Ω CMC 0,23 % 20 Hz do 50 Hz od 10 Ω do 15 Ω CMC 0,38 % 50 Hz do 100 Hz od 10 Ω do 15 Ω CMC 0,20 % 100 Hz do 100 kHz od 10 Ω do 15 Ω CMC 0,18 % 100 kHz do 1 MHz od 10 Ω do 15 Ω CMC 0,20 % 20 Hz do 50 Hz od 15 Ω do 50 Ω CMC 0,36 % 50 Hz do 100 Hz od 15 Ω do 50 Ω CMC 0,18 % 100 Hz do 1 MHz od 15 Ω do 50 Ω CMC 0,13 % 20 Hz do 50 Hz od 50 Ω do 2 kΩ CMC 0,34 % 50 Hz do 100 Hz od 50 Ω do 2 kΩ CMC 0,17 % 100 Hz do 1 MHz od 50 Ω do 2 kΩ CMC 0,12 % 20 Hz do 50 Hz od 2 kΩ do 4 kΩ CMC 0,33 % 50 Hz do 100 Hz od 2 kΩ do 4 kΩ CMC 0,16 % 100 Hz do 300 kHz od 2 kΩ do 4 kΩ CMC 0,11 % 300 kHz do 1 MHz od 2 kΩ do 4 kΩ CMC 0,17 % 20 Hz do 50 Hz od 4 kΩ do 20 kΩ CMC 0,34 % 50 Hz do 100 Hz od 4 kΩ do 20 kΩ CMC 0,16 % 100 Hz do 100 kHz od 4 kΩ do 20 kΩ CMC 0,11 % 100 kHz do 300 kHz od 4 kΩ do 20 kΩ CMC 0,17 % 300 kHz do 1 MHz od 4 kΩ do 20 kΩ CMC 0,19 % 20 Hz do 50 Hz od 20 kΩ do 100 kΩ CMC 0,37 % 50 Hz do 100 Hz od 20 kΩ do 100 kΩ CMC 0,19 % 100 Hz do 30 kHz od 20 kΩ do 100 kΩ CMC 0,13 % 30 kHz do 100 kHz od 20 kΩ do 100 kΩ CMC 0,17 % 100 kHz do 300 kHz od 20 kΩ do 100 kΩ CMC 0,20 % 300 kHz do 1 MHz od 20 kΩ do 100 kΩ CMC 0,28 % 20 Hz do 50 Hz od 100 kΩ do 320 kΩ CMC 0,46 % 50 Hz do 100 Hz od 100 kΩ do 320 kΩ CMC 0,26 % 100 Hz do 30 kHz od 100 kΩ do 320 kΩ CMC 0,15 % 30 kHz do 100 kHz od 100 kΩ do 320 kΩ CMC 0,20 % 100 kHz do 300 kHz od 100 kΩ do 320 kΩ CMC 0,28 % 300 kHz do 1 MHz od 100 kΩ do 320 kΩ CMC 0,55 % 20 Hz do 50 Hz od 320 kΩ do 400 kΩ CMC 0,49 % 50 Hz do 100 Hz od 320 kΩ do 400 kΩ CMC 0,28 % 100 Hz do 100 kHz od 320 kΩ do 400 kΩ CMC 0,21 % 100 kHz do 300 kHz od 320 kΩ do 400 kΩ CMC 0,31 % 300 kHz do 1 MHz od 320 kΩ do 400 kΩ CMC 0,65 % 20 Hz do 50 Hz od 400 kΩ do 500 kΩ CMC 0,53 % 50 Hz do 100 Hz od 400 kΩ do 500 kΩ CMC 0,31 % 100 Hz do 100 kHz od 400 kΩ do 500 kΩ CMC 0,22 % 100 kHz do 300 kHz od 400 kΩ do 500 kΩ CMC 0,34 % 300 kHz do 1 MHz od 400 kΩ do 500 kΩ CMC 0,77 % 20 Hz do 50 Hz od 500 kΩ do 700 kΩ CMC 0,61 % 50 Hz do 100 Hz od 500 kΩ do 700 kΩ CMC 0,37 % 100 Hz do 100 kHz od 500 kΩ do 700 kΩ CMC 0,25 % 100 kHz do 300 kHz od 500 kΩ do 700 kΩ CMC 0,42 % 300 kHz do 1 MHz od 500 kΩ do 700 kΩ CMC 1,1 % 20 Hz do 50 Hz od 700 kΩ do 900 kΩ CMC 0,69 % 50 Hz do 100 Hz od 700 kΩ do 900 kΩ CMC 0,43 % 100 Hz do 100 kHz od 700 kΩ do 900 kΩ CMC 0,27 % 100 kHz do 300 kHz od 700 kΩ do 900 kΩ CMC 0,49 % 300 kHz do 1 MHz od 700 kΩ do 900 kΩ CMC 1,3 % 20 Hz do 50 Hz od 900 kΩ do 1 MΩ CMC 0,73 % 50 Hz do 100 Hz od 900 kΩ do 1 MΩ CMC 0,46 % 100 Hz do 100 kHz od 900 kΩ do 1 MΩ CMC 0,28 % 100 kHz do 300 kHz od 900 kΩ do 1 MΩ CMC 0,53 % 300 kHz do 1 MHz od 900 kΩ do 1 MΩ CMC 1,4 % 20 Hz do 50 Hz od 1 MΩ do 2 MΩ CMC 1,2 % 50 Hz do 100 Hz od 1 MΩ do 2 MΩ CMC 0,75 % 100 Hz do 100 kHz od 1 MΩ do 2 MΩ CMC 0,41 % 100 kHz do 300 kHz od 1 MΩ do 2 MΩ CMC 0,90 % 300 kHz do 1 MHz od 1 MΩ do 2 MΩ CMC 2,7 % 20 Hz do 50 Hz od 2 MΩ do 4 MΩ CMC 2,0 % 50 Hz do 100 Hz od 2 MΩ do 4 MΩ CMC 1,4 % 100 Hz do 100 kHz od 2 MΩ do 4 MΩ CMC 0,65 % 100 kHz do 300 kHz od 2 MΩ do 4 MΩ CMC 1,7 % 300 kHz do 1 MHz od 2 MΩ do 4 MΩ CMC 5,1 % 20 Hz do 50 Hz od 4 MΩ do 6 MΩ CMC 2,8 % 50 Hz do 100 Hz od 4 MΩ do 6 MΩ CMC 2,0 % 100 Hz do 100 kHz od 4 MΩ do 6 MΩ CMC 0,90 % 100 kHz do 300 kHz od 4 MΩ do 6 MΩ CMC 2,4 % 300 kHz do 1 MHz od 4 MΩ do 6 MΩ CMC 7,6 % 20 Hz do 50 Hz od 6 MΩ do 8 MΩ CMC 3,6 % 50 Hz do 100 Hz od 6 MΩ do 8 MΩ CMC 2,6 % 100 Hz do 100 kHz od 6 MΩ do 8 MΩ CMC 1,2 % 100 kHz do 300 kHz od 6 MΩ do 8 MΩ CMC 3,2 % 20 Hz do 50 Hz od 8 MΩ do 10 MΩ CMC 4,4 % 50 Hz do 100 Hz od 8 MΩ do 10 MΩ CMC 3,2 % 100 Hz do 100 kHz od 8 MΩ do 10 MΩ CMC 1,4 % 100 kHz do 300 kHz od 8 MΩ do 10 MΩ CMC 3,9 % 20 Hz do 50 Hz od 10 MΩ do 15 MΩ CMC 6,4 % 50 Hz do 100 Hz od 10 MΩ do 15 MΩ CMC 4,8 % 100 Hz do 100 kHz od 10 MΩ do 15 MΩ CMC 2,2 % 100 kHz do 300 kHz od 10 MΩ do 15 MΩ CMC 5,8 % 20 Hz do 50 Hz od 15 MΩ do 20 MΩ CMC 8,4 % 50 Hz do 100 Hz od 15 MΩ do 20 MΩ CMC 6,3 % 100 Hz do 100 kHz od 15 MΩ do 20 MΩ CMC 2,8 % 100 kHz do 300 kHz od 15 MΩ do 20 MΩ CMC 7,6 % 100 Hz do 1 kHz od 20 MΩ do 25 MΩ CMC 3,5 % 1 kHz do 100 kHz od 20 MΩ do 25 MΩ CMC 3,3 % 100 Hz do 1 kHz od 25 MΩ do 30 MΩ CMC 4,1 % 1 kHz do 100 kHz od 25 MΩ do 30 MΩ CMC 3,9 % Stridavy odpor / Etalony stridaveho odporu pro kmitocty 20 Hz az 1 MHz Kalibrace – elektricke veliciny Prime mereni LCR meridlem 100 Hz az 100 kHz 50 mΩ az 0,1 Ω CMC 3,1 % 100 kHz az 300 kHz 50 mΩ az 0,1 Ω CMC 5,3 % 20 Hz az 50 Hz 0,1 Ω az 0,2 Ω CMC 4,9 % 50 Hz az 100 Hz 0,1 Ω az 0,2 Ω CMC 3,5 % 100 Hz az 100 kHz 0,1 Ω az 0,2 Ω CMC 1,6 % 100 kHz az 300 kHz 0,1 Ω az 0,2 Ω CMC 2,7 % 300 kHz az 1 MHz 0,1 Ω az 0,2 Ω CMC 3,9 % 20 Hz az 50 Hz 0,2 Ω az 0,5 Ω CMC 2,6 % 50 Hz az 100 Hz 0,2 Ω az 0,5 Ω CMC 1,9 % 100 Hz az 100 kHz 0,2 Ω az 0,5 Ω CMC 0,85 % 100 kHz az 300 kHz 0,2 Ω az 0,5 Ω CMC 1,5 % 300 kHz az 1 MHz 0,2 Ω az 0,5 Ω CMC 2,1 % 20 Hz az 50 Hz 0,5 Ω az 1 Ω CMC 1,3 % 50 Hz az 100 Hz 0,5 Ω az 1 Ω CMC 0,83 % 100 Hz az 100 kHz 0,5 Ω az 1 Ω CMC 0,44 % 100 kHz az 300 kHz 0,5 Ω az 1 Ω CMC 0,67 % 300 kHz az 1 MHz 0,5 Ω az 1 Ω CMC 0,90 % 20 Hz az 50 Hz 1 Ω az 5 Ω CMC 0,78 % 50 Hz az 100 Hz 1 Ω az 5 Ω CMC 0,49 % 100 Hz az 100 kHz 1 Ω az 5 Ω CMC 0,30 % 100 kHz az 300 kHz 1 Ω az 5 Ω CMC 0,41 % 300 kHz az 1 MHz 1 Ω az 5 Ω CMC 0,53 % 20 Hz az 50 Hz 5 Ω az 10 Ω CMC 0,42 % 50 Hz az 100 Hz 5 Ω az 10 Ω CMC 0,23 % 100 Hz az 100 kHz 5 Ω az 10 Ω CMC 0,19 % 100 kHz az 300 kHz 5 Ω az 10 Ω CMC 0,21 % 300 kHz az 1 MHz 5 Ω az 10 Ω CMC 0,23 % 20 Hz az 50 Hz 10 Ω az 15 Ω CMC 0,38 % 50 Hz az 100 Hz 10 Ω az 15 Ω CMC 0,20 % 100 Hz az 100 kHz 10 Ω az 15 Ω CMC 0,18 % 100 kHz az 1 MHz 10 Ω az 15 Ω CMC 0,20 % 20 Hz az 50 Hz 15 Ω az 50 Ω CMC 0,36 % 50 Hz az 100 Hz 15 Ω az 50 Ω CMC 0,18 % 100 Hz az 1 MHz 15 Ω az 50 Ω CMC 0,13 % 20 Hz az 50 Hz 50 Ω az 2 kΩ CMC 0,34 % 50 Hz az 100 Hz 50 Ω az 2 kΩ CMC 0,17 % 100 Hz az 1 MHz 50 Ω az 2 kΩ CMC 0,12 % 20 Hz az 50 Hz 2 kΩ az 4 kΩ CMC 0,33 % 50 Hz az 100 Hz 2 kΩ az 4 kΩ CMC 0,16 % 100 Hz az 300 kHz 2 kΩ az 4 kΩ CMC 0,11 % 300 kHz az 1 MHz 2 kΩ az 4 kΩ CMC 0,17 % 20 Hz az 50 Hz 4 kΩ az 20 kΩ CMC 0,34 % 50 Hz az 100 Hz 4 kΩ az 20 kΩ CMC 0,16 % 100 Hz az 100 kHz 4 kΩ az 20 kΩ CMC 0,11 % 100 kHz az 300 kHz 4 kΩ az 20 kΩ CMC 0,17 % 300 kHz az 1 MHz 4 kΩ az 20 kΩ CMC 0,19 % 20 Hz az 50 Hz 20 kΩ az 100 kΩ CMC 0,37 % 50 Hz az 100 Hz 20 kΩ az 100 kΩ CMC 0,19 % 100 Hz az 30 kHz 20 kΩ az 100 kΩ CMC 0,13 % 30 kHz az 100 kHz 20 kΩ az 100 kΩ CMC 0,17 % 100 kHz az 300 kHz 20 kΩ az 100 kΩ CMC 0,20 % 300 kHz az 1 MHz 20 kΩ az 100 kΩ CMC 0,28 % 20 Hz az 50 Hz 100 kΩ az 320 kΩ CMC 0,46 % 50 Hz az 100 Hz 100 kΩ az 320 kΩ CMC 0,26 % 100 Hz az 30 kHz 100 kΩ az 320 kΩ CMC 0,15 % 30 kHz az 100 kHz 100 kΩ az 320 kΩ CMC 0,20 % 100 kHz az 300 kHz 100 kΩ az 320 kΩ CMC 0,28 % 300 kHz az 1 MHz 100 kΩ az 320 kΩ CMC 0,55 % 20 Hz az 50 Hz 320 kΩ az 400 kΩ CMC 0,49 % 50 Hz az 100 Hz 320 kΩ az 400 kΩ CMC 0,28 % 100 Hz az 100 kHz 320 kΩ az 400 kΩ CMC 0,21 % 100 kHz az 300 kHz 320 kΩ az 400 kΩ CMC 0,31 % 300 kHz az 1 MHz 320 kΩ az 400 kΩ CMC 0,65 % 20 Hz az 50 Hz 400 kΩ az 500 kΩ CMC 0,53 % 50 Hz az 100 Hz 400 kΩ az 500 kΩ CMC 0,31 % 100 Hz az 100 kHz 400 kΩ az 500 kΩ CMC 0,22 % 100 kHz az 300 kHz 400 kΩ az 500 kΩ CMC 0,34 % 300 kHz az 1 MHz 400 kΩ az 500 kΩ CMC 0,77 % 20 Hz az 50 Hz 500 kΩ az 700 kΩ CMC 0,61 % 50 Hz az 100 Hz 500 kΩ az 700 kΩ CMC 0,37 % 100 Hz az 100 kHz 500 kΩ az 700 kΩ CMC 0,25 % 100 kHz az 300 kHz 500 kΩ az 700 kΩ CMC 0,42 % 300 kHz az 1 MHz 500 kΩ az 700 kΩ CMC 1,1 % 20 Hz az 50 Hz 700 kΩ az 900 kΩ CMC 0,69 % 50 Hz az 100 Hz 700 kΩ az 900 kΩ CMC 0,43 % 100 Hz az 100 kHz 700 kΩ az 900 kΩ CMC 0,27 % 100 kHz az 300 kHz 700 kΩ az 900 kΩ CMC 0,49 % 300 kHz az 1 MHz 700 kΩ az 900 kΩ CMC 1,3 % 20 Hz az 50 Hz 900 kΩ az 1 MΩ CMC 0,73 % 50 Hz az 100 Hz 900 kΩ az 1 MΩ CMC 0,46 % 100 Hz az 100 kHz 900 kΩ az 1 MΩ CMC 0,28 % 100 kHz az 300 kHz 900 kΩ az 1 MΩ CMC 0,53 % 300 kHz az 1 MHz 900 kΩ az 1 MΩ CMC 1,4 % 20 Hz az 50 Hz 1 MΩ az 2 MΩ CMC 1,2 % 50 Hz az 100 Hz 1 MΩ az 2 MΩ CMC 0,75 % 100 Hz az 100 kHz 1 MΩ az 2 MΩ CMC 0,41 % 100 kHz az 300 kHz 1 MΩ az 2 MΩ CMC 0,90 % 300 kHz az 1 MHz 1 MΩ az 2 MΩ CMC 2,7 % 20 Hz az 50 Hz 2 MΩ az 4 MΩ CMC 2,0 % 50 Hz az 100 Hz 2 MΩ az 4 MΩ CMC 1,4 % 100 Hz az 100 kHz 2 MΩ az 4 MΩ CMC 0,65 % 100 kHz az 300 kHz 2 MΩ az 4 MΩ CMC 1,7 % 300 kHz az 1 MHz 2 MΩ az 4 MΩ CMC 5,1 % 20 Hz az 50 Hz 4 MΩ az 6 MΩ CMC 2,8 % 50 Hz az 100 Hz 4 MΩ az 6 MΩ CMC 2,0 % 100 Hz az 100 kHz 4 MΩ az 6 MΩ CMC 0,90 % 100 kHz az 300 kHz 4 MΩ az 6 MΩ CMC 2,4 % 300 kHz az 1 MHz 4 MΩ az 6 MΩ CMC 7,6 % 20 Hz az 50 Hz 6 MΩ az 8 MΩ CMC 3,6 % 50 Hz az 100 Hz 6 MΩ az 8 MΩ CMC 2,6 % 100 Hz az 100 kHz 6 MΩ az 8 MΩ CMC 1,2 % 100 kHz az 300 kHz 6 MΩ az 8 MΩ CMC 3,2 % 20 Hz az 50 Hz 8 MΩ az 10 MΩ CMC 4,4 % 50 Hz az 100 Hz 8 MΩ az 10 MΩ CMC 3,2 % 100 Hz az 100 kHz 8 MΩ az 10 MΩ CMC 1,4 % 100 kHz az 300 kHz 8 MΩ az 10 MΩ CMC 3,9 % 20 Hz az 50 Hz 10 MΩ az 15 MΩ CMC 6,4 % 50 Hz az 100 Hz 10 MΩ az 15 MΩ CMC 4,8 % 100 Hz az 100 kHz 10 MΩ az 15 MΩ CMC 2,2 % 100 kHz az 300 kHz 10 MΩ az 15 MΩ CMC 5,8 % 20 Hz az 50 Hz 15 MΩ az 20 MΩ CMC 8,4 % 50 Hz az 100 Hz 15 MΩ az 20 MΩ CMC 6,3 % 100 Hz az 100 kHz 15 MΩ az 20 MΩ CMC 2,8 % 100 kHz az 300 kHz 15 MΩ az 20 MΩ CMC 7,6 % 100 Hz az 1 kHz 20 MΩ az 25 MΩ CMC 3,5 % 1 kHz az 100 kHz 20 MΩ az 25 MΩ CMC 3,3 % 100 Hz az 1 kHz 25 MΩ az 30 MΩ CMC 4,1 % 1 kHz az 100 kHz 25 MΩ az 30 MΩ CMC 3,9 % TP6, TP24","search_en":"AC resistance / AC resistance standards for frequencies from 20 Hz to 1 MHz Calibration – electrical quantities Direct measurement by a LCR meter 100 Hz to 100 kHz 50 mΩ to 0,1 Ω CMC 3,1 % 100 kHz to 300 kHz 50 mΩ to 0,1 Ω CMC 5,3 % 20 Hz to 50 Hz 0,1 Ω to 0,2 Ω CMC 4,9 % 50 Hz to 100 Hz 0,1 Ω to 0,2 Ω CMC 3,5 % 100 Hz to 100 kHz 0,1 Ω to 0,2 Ω CMC 1,6 % 100 kHz to 300 kHz 0,1 Ω to 0,2 Ω CMC 2,7 % 300 kHz to 1 MHz 0,1 Ω to 0,2 Ω CMC 3,9 % 20 Hz to 50 Hz 0,2 Ω to 0,5 Ω CMC 2,6 % 50 Hz to 100 Hz 0,2 Ω to 0,5 Ω CMC 1,9 % 100 Hz to 100 kHz 0,2 Ω to 0,5 Ω CMC 0,85 % 100 kHz to 300 kHz 0,2 Ω to 0,5 Ω CMC 1,5 % 300 kHz to 1 MHz 0,2 Ω to 0,5 Ω CMC 2,1 % 20 Hz to 50 Hz 0,5 Ω to 1 Ω CMC 1,3 % 50 Hz to 100 Hz 0,5 Ω to 1 Ω CMC 0,83 % 100 Hz to 100 kHz 0,5 Ω to 1 Ω CMC 0,44 % 100 kHz to 300 kHz 0,5 Ω to 1 Ω CMC 0,67 % 300 kHz to 1 MHz 0,5 Ω to 1 Ω CMC 0,90 % 20 Hz to 50 Hz 1 Ω to 5 Ω CMC 0,78 % 50 Hz to 100 Hz 1 Ω to 5 Ω CMC 0,49 % 100 Hz to 100 kHz 1 Ω to 5 Ω CMC 0,30 % 100 kHz to 300 kHz 1 Ω to 5 Ω CMC 0,41 % 300 kHz to 1 MHz 1 Ω to 5 Ω CMC 0,53 % 20 Hz to 50 Hz 5 Ω to 10 Ω CMC 0,42 % 50 Hz to 100 Hz 5 Ω to 10 Ω CMC 0,23 % 100 Hz to 100 kHz 5 Ω to 10 Ω CMC 0,19 % 100 kHz to 300 kHz 5 Ω to 10 Ω CMC 0,21 % 300 kHz to 1 MHz 5 Ω to 10 Ω CMC 0,23 % 20 Hz to 50 Hz 10 Ω to 15 Ω CMC 0,38 % 50 Hz to 100 Hz 10 Ω to 15 Ω CMC 0,20 % 100 Hz to 100 kHz 10 Ω to 15 Ω CMC 0,18 % 100 kHz to 1 MHz 10 Ω to 15 Ω CMC 0,20 % 20 Hz to 50 Hz 15 Ω to 50 Ω CMC 0,36 % 50 Hz to 100 Hz 15 Ω to 50 Ω CMC 0,18 % 100 Hz to 1 MHz 15 Ω to 50 Ω CMC 0,13 % 20 Hz to 50 Hz 50 Ω to 2 kΩ CMC 0,34 % 50 Hz to 100 Hz 50 Ω to 2 kΩ CMC 0,17 % 100 Hz to 1 MHz 50 Ω to 2 kΩ CMC 0,12 % 20 Hz to 50 Hz 2 kΩ to 4 kΩ CMC 0,33 % 50 Hz to 100 Hz 2 kΩ to 4 kΩ CMC 0,16 % 100 Hz to 300 kHz 2 kΩ to 4 kΩ CMC 0,11 % 300 kHz to 1 MHz 2 kΩ to 4 kΩ CMC 0,17 % 20 Hz to 50 Hz 4 kΩ to 20 kΩ CMC 0,34 % 50 Hz to 100 Hz 4 kΩ to 20 kΩ CMC 0,16 % 100 Hz to 100 kHz 4 kΩ to 20 kΩ CMC 0,11 % 100 kHz to 300 kHz 4 kΩ to 20 kΩ CMC 0,17 % 300 kHz to 1 MHz 4 kΩ to 20 kΩ CMC 0,19 % 20 Hz to 50 Hz 20 kΩ to 100 kΩ CMC 0,37 % 50 Hz to 100 Hz 20 kΩ to 100 kΩ CMC 0,19 % 100 Hz to 30 kHz 20 kΩ to 100 kΩ CMC 0,13 % 30 kHz to 100 kHz 20 kΩ to 100 kΩ CMC 0,17 % 100 kHz to 300 kHz 20 kΩ to 100 kΩ CMC 0,20 % 300 kHz to 1 MHz 20 kΩ to 100 kΩ CMC 0,28 % 20 Hz to 50 Hz 100 kΩ to 320 kΩ CMC 0,46 % 50 Hz to 100 Hz 100 kΩ to 320 kΩ CMC 0,26 % 100 Hz to 30 kHz 100 kΩ to 320 kΩ CMC 0,15 % 30 kHz to 100 kHz 100 kΩ to 320 kΩ CMC 0,20 % 100 kHz to 300 kHz 100 kΩ to 320 kΩ CMC 0,28 % 300 kHz to 1 MHz 100 kΩ to 320 kΩ CMC 0,55 % 20 Hz to 50 Hz 320 kΩ to 400 kΩ CMC 0,49 % 50 Hz to 100 Hz 320 kΩ to 400 kΩ CMC 0,28 % 100 Hz to 100 kHz 320 kΩ to 400 kΩ CMC 0,21 % 100 kHz to 300 kHz 320 kΩ to 400 kΩ CMC 0,31 % 300 kHz to 1 MHz 320 kΩ to 400 kΩ CMC 0,65 % 20 Hz to 50 Hz 400 kΩ to 500 kΩ CMC 0,53 % 50 Hz to 100 Hz 400 kΩ to 500 kΩ CMC 0,31 % 100 Hz to 100 kHz 400 kΩ to 500 kΩ CMC 0,22 % 100 kHz to 300 kHz 400 kΩ to 500 kΩ CMC 0,34 % 300 kHz to 1 MHz 400 kΩ to 500 kΩ CMC 0,77 % 20 Hz to 50 Hz 500 kΩ to 700 kΩ CMC 0,61 % 50 Hz to 100 Hz 500 kΩ to 700 kΩ CMC 0,37 % 100 Hz to 100 kHz 500 kΩ to 700 kΩ CMC 0,25 % 100 kHz to 300 kHz 500 kΩ to 700 kΩ CMC 0,42 % 300 kHz to 1 MHz 500 kΩ to 700 kΩ CMC 1,1 % 20 Hz to 50 Hz 700 kΩ to 900 kΩ CMC 0,69 % 50 Hz to 100 Hz 700 kΩ to 900 kΩ CMC 0,43 % 100 Hz to 100 kHz 700 kΩ to 900 kΩ CMC 0,27 % 100 kHz to 300 kHz 700 kΩ to 900 kΩ CMC 0,49 % 300 kHz to 1 MHz 700 kΩ to 900 kΩ CMC 1,3 % 20 Hz to 50 Hz 900 kΩ to 1 MΩ CMC 0,73 % 50 Hz to 100 Hz 900 kΩ to 1 MΩ CMC 0,46 % 100 Hz to 100 kHz 900 kΩ to 1 MΩ CMC 0,28 % 100 kHz to 300 kHz 900 kΩ to 1 MΩ CMC 0,53 % 300 kHz to 1 MHz 900 kΩ to 1 MΩ CMC 1,4 % 20 Hz to 50 Hz 1 MΩ to 2 MΩ CMC 1,2 % 50 Hz to 100 Hz 1 MΩ to 2 MΩ CMC 0,75 % 100 Hz to 100 kHz 1 MΩ to 2 MΩ CMC 0,41 % 100 kHz to 300 kHz 1 MΩ to 2 MΩ CMC 0,90 % 300 kHz to 1 MHz 1 MΩ to 2 MΩ CMC 2,7 % 20 Hz to 50 Hz 2 MΩ to 4 MΩ CMC 2,0 % 50 Hz to 100 Hz 2 MΩ to 4 MΩ CMC 1,4 % 100 Hz to 100 kHz 2 MΩ to 4 MΩ CMC 0,65 % 100 kHz to 300 kHz 2 MΩ to 4 MΩ CMC 1,7 % 300 kHz to 1 MHz 2 MΩ to 4 MΩ CMC 5,1 % 20 Hz to 50 Hz 4 MΩ to 6 MΩ CMC 2,8 % 50 Hz to 100 Hz 4 MΩ to 6 MΩ CMC 2,0 % 100 Hz to 100 kHz 4 MΩ to 6 MΩ CMC 0,90 % 100 kHz to 300 kHz 4 MΩ to 6 MΩ CMC 2,4 % 300 kHz to 1 MHz 4 MΩ to 6 MΩ CMC 7,6 % 20 Hz to 50 Hz 6 MΩ to 8 MΩ CMC 3,6 % 50 Hz to 100 Hz 6 MΩ to 8 MΩ CMC 2,6 % 100 Hz to 100 kHz 6 MΩ to 8 MΩ CMC 1,2 % 100 kHz to 300 kHz 6 MΩ to 8 MΩ CMC 3,2 % 20 Hz to 50 Hz 8 MΩ to 10 MΩ CMC 4,4 % 50 Hz to 100 Hz 8 MΩ to 10 MΩ CMC 3,2 % 100 Hz to 100 kHz 8 MΩ to 10 MΩ CMC 1,4 % 100 kHz to 300 kHz 8 MΩ to 10 MΩ CMC 3,9 % 20 Hz to 50 Hz 10 MΩ to 15 MΩ CMC 6,4 % 50 Hz to 100 Hz 10 MΩ to 15 MΩ CMC 4,8 % 100 Hz to 100 kHz 10 MΩ to 15 MΩ CMC 2,2 % 100 kHz to 300 kHz 10 MΩ to 15 MΩ CMC 5,8 % 20 Hz to 50 Hz 15 MΩ to 20 MΩ CMC 8,4 % 50 Hz to 100 Hz 15 MΩ to 20 MΩ CMC 6,3 % 100 Hz to 100 kHz 15 MΩ to 20 MΩ CMC 2,8 % 100 kHz to 300 kHz 15 MΩ to 20 MΩ CMC 7,6 % 100 Hz to 1 kHz 20 MΩ to 25 MΩ CMC 3,5 % 1 kHz to 100 kHz 20 MΩ to 25 MΩ CMC 3,3 % 100 Hz to 1 kHz 25 MΩ to 30 MΩ CMC 4,1 % 1 kHz to 100 kHz 25 MΩ to 30 MΩ CMC 3,9 % TP6, TP24","search_zh":"交流电阻 / 频率 20 Hz 至 1 MHz 的交流电阻标准器 校准 – 电学量 用 LCR 表直接测量 100 Hz 至 100 kHz 50 mΩ 至 0,1 Ω CMC 3,1 % 100 kHz 至 300 kHz 50 mΩ 至 0,1 Ω CMC 5,3 % 20 Hz 至 50 Hz 0,1 Ω 至 0,2 Ω CMC 4,9 % 50 Hz 至 100 Hz 0,1 Ω 至 0,2 Ω CMC 3,5 % 100 Hz 至 100 kHz 0,1 Ω 至 0,2 Ω CMC 1,6 % 100 kHz 至 300 kHz 0,1 Ω 至 0,2 Ω CMC 2,7 % 300 kHz 至 1 MHz 0,1 Ω 至 0,2 Ω CMC 3,9 % 20 Hz 至 50 Hz 0,2 Ω 至 0,5 Ω CMC 2,6 % 50 Hz 至 100 Hz 0,2 Ω 至 0,5 Ω CMC 1,9 % 100 Hz 至 100 kHz 0,2 Ω 至 0,5 Ω CMC 0,85 % 100 kHz 至 300 kHz 0,2 Ω 至 0,5 Ω CMC 1,5 % 300 kHz 至 1 MHz 0,2 Ω 至 0,5 Ω CMC 2,1 % 20 Hz 至 50 Hz 0,5 Ω 至 1 Ω CMC 1,3 % 50 Hz 至 100 Hz 0,5 Ω 至 1 Ω CMC 0,83 % 100 Hz 至 100 kHz 0,5 Ω 至 1 Ω CMC 0,44 % 100 kHz 至 300 kHz 0,5 Ω 至 1 Ω CMC 0,67 % 300 kHz 至 1 MHz 0,5 Ω 至 1 Ω CMC 0,90 % 20 Hz 至 50 Hz 1 Ω 至 5 Ω CMC 0,78 % 50 Hz 至 100 Hz 1 Ω 至 5 Ω CMC 0,49 % 100 Hz 至 100 kHz 1 Ω 至 5 Ω CMC 0,30 % 100 kHz 至 300 kHz 1 Ω 至 5 Ω CMC 0,41 % 300 kHz 至 1 MHz 1 Ω 至 5 Ω CMC 0,53 % 20 Hz 至 50 Hz 5 Ω 至 10 Ω CMC 0,42 % 50 Hz 至 100 Hz 5 Ω 至 10 Ω CMC 0,23 % 100 Hz 至 100 kHz 5 Ω 至 10 Ω CMC 0,19 % 100 kHz 至 300 kHz 5 Ω 至 10 Ω CMC 0,21 % 300 kHz 至 1 MHz 5 Ω 至 10 Ω CMC 0,23 % 20 Hz 至 50 Hz 10 Ω 至 15 Ω CMC 0,38 % 50 Hz 至 100 Hz 10 Ω 至 15 Ω CMC 0,20 % 100 Hz 至 100 kHz 10 Ω 至 15 Ω CMC 0,18 % 100 kHz 至 1 MHz 10 Ω 至 15 Ω CMC 0,20 % 20 Hz 至 50 Hz 15 Ω 至 50 Ω CMC 0,36 % 50 Hz 至 100 Hz 15 Ω 至 50 Ω CMC 0,18 % 100 Hz 至 1 MHz 15 Ω 至 50 Ω CMC 0,13 % 20 Hz 至 50 Hz 50 Ω 至 2 kΩ CMC 0,34 % 50 Hz 至 100 Hz 50 Ω 至 2 kΩ CMC 0,17 % 100 Hz 至 1 MHz 50 Ω 至 2 kΩ CMC 0,12 % 20 Hz 至 50 Hz 2 kΩ 至 4 kΩ CMC 0,33 % 50 Hz 至 100 Hz 2 kΩ 至 4 kΩ CMC 0,16 % 100 Hz 至 300 kHz 2 kΩ 至 4 kΩ CMC 0,11 % 300 kHz 至 1 MHz 2 kΩ 至 4 kΩ CMC 0,17 % 20 Hz 至 50 Hz 4 kΩ 至 20 kΩ CMC 0,34 % 50 Hz 至 100 Hz 4 kΩ 至 20 kΩ CMC 0,16 % 100 Hz 至 100 kHz 4 kΩ 至 20 kΩ CMC 0,11 % 100 kHz 至 300 kHz 4 kΩ 至 20 kΩ CMC 0,17 % 300 kHz 至 1 MHz 4 kΩ 至 20 kΩ CMC 0,19 % 20 Hz 至 50 Hz 20 kΩ 至 100 kΩ CMC 0,37 % 50 Hz 至 100 Hz 20 kΩ 至 100 kΩ CMC 0,19 % 100 Hz 至 30 kHz 20 kΩ 至 100 kΩ CMC 0,13 % 30 kHz 至 100 kHz 20 kΩ 至 100 kΩ CMC 0,17 % 100 kHz 至 300 kHz 20 kΩ 至 100 kΩ CMC 0,20 % 300 kHz 至 1 MHz 20 kΩ 至 100 kΩ CMC 0,28 % 20 Hz 至 50 Hz 100 kΩ 至 320 kΩ CMC 0,46 % 50 Hz 至 100 Hz 100 kΩ 至 320 kΩ CMC 0,26 % 100 Hz 至 30 kHz 100 kΩ 至 320 kΩ CMC 0,15 % 30 kHz 至 100 kHz 100 kΩ 至 320 kΩ CMC 0,20 % 100 kHz 至 300 kHz 100 kΩ 至 320 kΩ CMC 0,28 % 300 kHz 至 1 MHz 100 kΩ 至 320 kΩ CMC 0,55 % 20 Hz 至 50 Hz 320 kΩ 至 400 kΩ CMC 0,49 % 50 Hz 至 100 Hz 320 kΩ 至 400 kΩ CMC 0,28 % 100 Hz 至 100 kHz 320 kΩ 至 400 kΩ CMC 0,21 % 100 kHz 至 300 kHz 320 kΩ 至 400 kΩ CMC 0,31 % 300 kHz 至 1 MHz 320 kΩ 至 400 kΩ CMC 0,65 % 20 Hz 至 50 Hz 400 kΩ 至 500 kΩ CMC 0,53 % 50 Hz 至 100 Hz 400 kΩ 至 500 kΩ CMC 0,31 % 100 Hz 至 100 kHz 400 kΩ 至 500 kΩ CMC 0,22 % 100 kHz 至 300 kHz 400 kΩ 至 500 kΩ CMC 0,34 % 300 kHz 至 1 MHz 400 kΩ 至 500 kΩ CMC 0,77 % 20 Hz 至 50 Hz 500 kΩ 至 700 kΩ CMC 0,61 % 50 Hz 至 100 Hz 500 kΩ 至 700 kΩ CMC 0,37 % 100 Hz 至 100 kHz 500 kΩ 至 700 kΩ CMC 0,25 % 100 kHz 至 300 kHz 500 kΩ 至 700 kΩ CMC 0,42 % 300 kHz 至 1 MHz 500 kΩ 至 700 kΩ CMC 1,1 % 20 Hz 至 50 Hz 700 kΩ 至 900 kΩ CMC 0,69 % 50 Hz 至 100 Hz 700 kΩ 至 900 kΩ CMC 0,43 % 100 Hz 至 100 kHz 700 kΩ 至 900 kΩ CMC 0,27 % 100 kHz 至 300 kHz 700 kΩ 至 900 kΩ CMC 0,49 % 300 kHz 至 1 MHz 700 kΩ 至 900 kΩ CMC 1,3 % 20 Hz 至 50 Hz 900 kΩ 至 1 MΩ CMC 0,73 % 50 Hz 至 100 Hz 900 kΩ 至 1 MΩ CMC 0,46 % 100 Hz 至 100 kHz 900 kΩ 至 1 MΩ CMC 0,28 % 100 kHz 至 300 kHz 900 kΩ 至 1 MΩ CMC 0,53 % 300 kHz 至 1 MHz 900 kΩ 至 1 MΩ CMC 1,4 % 20 Hz 至 50 Hz 1 MΩ 至 2 MΩ CMC 1,2 % 50 Hz 至 100 Hz 1 MΩ 至 2 MΩ CMC 0,75 % 100 Hz 至 100 kHz 1 MΩ 至 2 MΩ CMC 0,41 % 100 kHz 至 300 kHz 1 MΩ 至 2 MΩ CMC 0,90 % 300 kHz 至 1 MHz 1 MΩ 至 2 MΩ CMC 2,7 % 20 Hz 至 50 Hz 2 MΩ 至 4 MΩ CMC 2,0 % 50 Hz 至 100 Hz 2 MΩ 至 4 MΩ CMC 1,4 % 100 Hz 至 100 kHz 2 MΩ 至 4 MΩ CMC 0,65 % 100 kHz 至 300 kHz 2 MΩ 至 4 MΩ CMC 1,7 % 300 kHz 至 1 MHz 2 MΩ 至 4 MΩ CMC 5,1 % 20 Hz 至 50 Hz 4 MΩ 至 6 MΩ CMC 2,8 % 50 Hz 至 100 Hz 4 MΩ 至 6 MΩ CMC 2,0 % 100 Hz 至 100 kHz 4 MΩ 至 6 MΩ CMC 0,90 % 100 kHz 至 300 kHz 4 MΩ 至 6 MΩ CMC 2,4 % 300 kHz 至 1 MHz 4 MΩ 至 6 MΩ CMC 7,6 % 20 Hz 至 50 Hz 6 MΩ 至 8 MΩ CMC 3,6 % 50 Hz 至 100 Hz 6 MΩ 至 8 MΩ CMC 2,6 % 100 Hz 至 100 kHz 6 MΩ 至 8 MΩ CMC 1,2 % 100 kHz 至 300 kHz 6 MΩ 至 8 MΩ CMC 3,2 % 20 Hz 至 50 Hz 8 MΩ 至 10 MΩ CMC 4,4 % 50 Hz 至 100 Hz 8 MΩ 至 10 MΩ CMC 3,2 % 100 Hz 至 100 kHz 8 MΩ 至 10 MΩ CMC 1,4 % 100 kHz 至 300 kHz 8 MΩ 至 10 MΩ CMC 3,9 % 20 Hz 至 50 Hz 10 MΩ 至 15 MΩ CMC 6,4 % 50 Hz 至 100 Hz 10 MΩ 至 15 MΩ CMC 4,8 % 100 Hz 至 100 kHz 10 MΩ 至 15 MΩ CMC 2,2 % 100 kHz 至 300 kHz 10 MΩ 至 15 MΩ CMC 5,8 % 20 Hz 至 50 Hz 15 MΩ 至 20 MΩ CMC 8,4 % 50 Hz 至 100 Hz 15 MΩ 至 20 MΩ CMC 6,3 % 100 Hz 至 100 kHz 15 MΩ 至 20 MΩ CMC 2,8 % 100 kHz 至 300 kHz 15 MΩ 至 20 MΩ CMC 7,6 % 100 Hz 至 1 kHz 20 MΩ 至 25 MΩ CMC 3,5 % 1 kHz 至 100 kHz 20 MΩ 至 25 MΩ CMC 3,3 % 100 Hz 至 1 kHz 25 MΩ 至 30 MΩ CMC 4,1 % 1 kHz 至 100 kHz 25 MΩ 至 30 MΩ CMC 3,9 % TP6, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bec6d2d45b684ee5bff815a8","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja przy prądzie przemiennym / Wzorce rezystancji przy prądzie przemiennym dla częstotliwości od 1 MHz do 8 MHz","test_object_en":"AC resistance / AC resistance standards for frequencies from 1 MHz to 8 MHz","test_object_zh":"交流电阻 / 频率 1 MHz 至 8 MHz 的交流电阻标准器","test_object_cs":"Střídavý odpor / Etalony střídavého odporu pro kmitočty 1 MHz až 8 MHz","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 MHz do 2 MHz","range":"od 0,5 Ω do 0,6 Ω","cmc":"8,7 %"},{"name":"1 MHz do 2 MHz","range":"od 0,6 Ω do 0,7 Ω","cmc":"7,3 %"},{"name":"2 MHz do 3 MHz","range":"od 0,6 Ω do 0,7 Ω","cmc":"8,7 %"},{"name":"1 MHz do 2 MHz","range":"od 0,7 Ω do 0,8 Ω","cmc":"6,2 %"},{"name":"2 MHz do 3 MHz","range":"od 0,7 Ω do 0,8 Ω","cmc":"7,5 %"},{"name":"3 MHz do 4 MHz","range":"od 0,7 Ω do 0,8 Ω","cmc":"8,7 %"},{"name":"1 MHz do 2 MHz","range":"od 0,8 Ω do 0,9 Ω","cmc":"5,5 %"},{"name":"2 MHz do 3 MHz","range":"od 0,8 Ω do 0,9 Ω","cmc":"6,5 %"},{"name":"3 MHz do 4 MHz","range":"od 0,8 Ω do 0,9 Ω","cmc":"7,6 %"},{"name":"4 MHz do 5 MHz","range":"od 0,8 Ω do 0,9 Ω","cmc":"8,7 %"},{"name":"1 MHz do 2 MHz","range":"od 0,9 Ω do 1 Ω","cmc":"4,9 %"},{"name":"2 MHz do 3 MHz","range":"od 0,9 Ω do 1 Ω","cmc":"5,8 %"},{"name":"3 MHz do 4 MHz","range":"od 0,9 Ω do 1 Ω","cmc":"6,8 %"},{"name":"4 MHz do 5 MHz","range":"od 0,9 Ω do 1 Ω","cmc":"7,8 %"},{"name":"1 MHz do 2 MHz","range":"od 3 Ω do 4 Ω","cmc":"8,0 %"},{"name":"2 MHz do 3 MHz","range":"od 3 Ω do 4 Ω","cmc":"9,6 %"},{"name":"1 MHz do 2 MHz","range":"od 4 Ω do 5 Ω","cmc":"6,2 %"},{"name":"2 MHz do 3 MHz","range":"od 4 Ω do 5 Ω","cmc":"7,4 %"},{"name":"3 MHz do 4 MHz","range":"od 4 Ω do 5 Ω","cmc":"8,6 %"},{"name":"4 MHz do 5 MHz","range":"od 4 Ω do 5 Ω","cmc":"9,9 %"},{"name":"1 MHz do 2 MHz","range":"od 5 Ω do 6 Ω","cmc":"5,1 %"},{"name":"2 MHz do 3 MHz","range":"od 5 Ω do 6 Ω","cmc":"6,1 %"},{"name":"3 MHz do 4 MHz","range":"od 5 Ω do 6 Ω","cmc":"7,1 %"},{"name":"4 MHz do 5 MHz","range":"od 5 Ω do 6 Ω","cmc":"8,1 %"},{"name":"1 MHz do 2 MHz","range":"od 6 Ω do 7 Ω","cmc":"4,4 %"},{"name":"2 MHz do 3 MHz","range":"od 6 Ω do 7 Ω","cmc":"5,2 %"},{"name":"3 MHz do 4 MHz","range":"od 6 Ω do 7 Ω","cmc":"6,1 %"},{"name":"4 MHz do 5 MHz","range":"od 6 Ω do 7 Ω","cmc":"7,0 %"},{"name":"1 MHz do 2 MHz","range":"od 7 Ω do 8 Ω","cmc":"3,9 %"},{"name":"2 MHz do 3 MHz","range":"od 7 Ω do 8 Ω","cmc":"4,6 %"},{"name":"3 MHz do 4 MHz","range":"od 7 Ω do 8 Ω","cmc":"5,4 %"},{"name":"4 MHz do 5 MHz","range":"od 7 Ω do 8 Ω","cmc":"6,2 %"},{"name":"5 MHz do 6 MHz","range":"od 7 Ω do 8 Ω","cmc":"9,2 %"},{"name":"1 MHz do 2 MHz","range":"od 8 Ω do 9 Ω","cmc":"3,5 %"},{"name":"2 MHz do 3 MHz","range":"od 8 Ω do 9 Ω","cmc":"4,2 %"},{"name":"3 MHz do 4 MHz","range":"od 8 Ω do 9 Ω","cmc":"4,8 %"},{"name":"4 MHz do 5 MHz","range":"od 8 Ω do 9 Ω","cmc":"5,5 %"},{"name":"5 MHz do 6 MHz","range":"od 8 Ω do 9 Ω","cmc":"8,3 %"},{"name":"6 MHz do 7 MHz","range":"od 8 Ω do 9 Ω","cmc":"9,6 %"},{"name":"1 MHz do 2 MHz","range":"od 9 Ω do 10 Ω","cmc":"3,2 %"},{"name":"2 MHz do 3 MHz","range":"od 9 Ω do 10 Ω","cmc":"3,8 %"},{"name":"3 MHz do 4 MHz","range":"od 9 Ω do 10 Ω","cmc":"4,4 %"},{"name":"4 MHz do 5 MHz","range":"od 9 Ω do 10 Ω","cmc":"5,5 %"},{"name":"5 MHz do 6 MHz","range":"od 9 Ω do 10 Ω","cmc":"7,6 %"},{"name":"6 MHz do 7 MHz","range":"od 9 Ω do 10 Ω","cmc":"8,8 %"},{"name":"1 MHz do 2 MHz","range":"od 10 Ω do 20 Ω","cmc":"4,8 %"},{"name":"2 MHz do 3 MHz","range":"od 10 Ω do 20 Ω","cmc":"5,8 %"},{"name":"3 MHz do 4 MHz","range":"od 10 Ω do 20 Ω","cmc":"6,7 %"},{"name":"4 MHz do 5 MHz","range":"od 10 Ω do 20 Ω","cmc":"7,7 %"},{"name":"1 MHz do 2 MHz","range":"od 20 Ω do 30 Ω","cmc":"3,4 %"},{"name":"2 MHz do 3 MHz","range":"od 20 Ω do 30 Ω","cmc":"4,0 %"},{"name":"3 MHz do 4 MHz","range":"od 20 Ω do 30 Ω","cmc":"4,7 %"},{"name":"4 MHz do 5 MHz","range":"od 20 Ω do 30 Ω","cmc":"5,4 %"},{"name":"5 MHz do 6 MHz","range":"od 20 Ω do 30 Ω","cmc":"8,0 %"},{"name":"6 MHz do 7 MHz","range":"od 20 Ω do 30 Ω","cmc":"9,3 %"},{"name":"1 MHz do 2 MHz","range":"od 30 Ω do 50 Ω","cmc":"2,9 %"},{"name":"2 MHz do 3 MHz","range":"od 30 Ω do 50 Ω","cmc":"3,5 %"},{"name":"3 MHz do 4 MHz","range":"od 30 Ω do 50 Ω","cmc":"4,0 %"},{"name":"4 MHz do 5 MHz","range":"od 30 Ω do 50 Ω","cmc":"4,6 %"},{"name":"5 MHz do 6 MHz","range":"od 30 Ω do 50 Ω","cmc":"6,9 %"},{"name":"6 MHz do 7 MHz","range":"od 30 Ω do 50 Ω","cmc":"8,0 %"},{"name":"7 MHz do 8 MHz","range":"od 30 Ω do 50 Ω","cmc":"9,1 %"},{"name":"1 MHz do 2 MHz","range":"od 50 Ω do 100 Ω","cmc":"2,5 %"},{"name":"2 MHz do 3 MHz","range":"od 50 Ω do 100 Ω","cmc":"3,0 %"},{"name":"3 MHz do 4 MHz","range":"od 50 Ω do 100 Ω","cmc":"3,5 %"},{"name":"4 MHz do 5 MHz","range":"od 50 Ω do 100 Ω","cmc":"4,0 %"},{"name":"5 MHz do 6 MHz","range":"od 50 Ω do 100 Ω","cmc":"5,9 %"},{"name":"6 MHz do 7 MHz","range":"od 50 Ω do 100 Ω","cmc":"6,9 %"},{"name":"7 MHz do 8 MHz","range":"od 50 Ω do 100 Ω","cmc":"7,9 %"},{"name":"1 MHz do 2 MHz","range":"od 100 Ω do 300 Ω","cmc":"2,8 %"},{"name":"2 MHz do 3 MHz","range":"od 100 Ω do 300 Ω","cmc":"3,3 %"},{"name":"3 MHz do 4 MHz","range":"od 100 Ω do 300 Ω","cmc":"3,9 %"},{"name":"4 MHz do 5 MHz","range":"od 100 Ω do 300 Ω","cmc":"4,4 %"},{"name":"5 MHz do 6 MHz","range":"od 100 Ω do 300 Ω","cmc":"6,8 %"},{"name":"6 MHz do 7 MHz","range":"od 100 Ω do 300 Ω","cmc":"7,7 %"},{"name":"7 MHz do 8 MHz","range":"od 100 Ω do 300 Ω","cmc":"8,8 %"},{"name":"1 MHz do 2 MHz","range":"od 300 Ω do 500 Ω","cmc":"3,4 %"},{"name":"2 MHz do 3 MHz","range":"od 300 Ω do 500 Ω","cmc":"4,0 %"},{"name":"3 MHz do 4 MHz","range":"od 300 Ω do 500 Ω","cmc":"4,7 %"},{"name":"4 MHz do 5 MHz","range":"od 300 Ω do 500 Ω","cmc":"5,4 %"},{"name":"5 MHz do 6 MHz","range":"od 300 Ω do 500 Ω","cmc":"8,0 %"},{"name":"6 MHz do 7 MHz","range":"od 300 Ω do 500 Ω","cmc":"9,3 %"},{"name":"1 MHz do 2 MHz","range":"od 500 Ω do 700 Ω","cmc":"3,9 %"},{"name":"2 MHz do 3 MHz","range":"od 500 Ω do 700 Ω","cmc":"4,6 %"},{"name":"3 MHz do 4 MHz","range":"od 500 Ω do 700 Ω","cmc":"5,5 %"},{"name":"4 MHz do 5 MHz","range":"od 500 Ω do 700 Ω","cmc":"6,3 %"},{"name":"5 MHz do 6 MHz","range":"od 500 Ω do 700 Ω","cmc":"9,4 %"},{"name":"1 MHz do 2 MHz","range":"od 700 Ω do 1 kΩ","cmc":"4,8 %"},{"name":"2 MHz do 3 MHz","range":"od 700 Ω do 1 kΩ","cmc":"5,7 %"},{"name":"3 MHz do 4 MHz","range":"od 700 Ω do 1 kΩ","cmc":"6,7 %"},{"name":"4 MHz do 5 MHz","range":"od 700 Ω do 1 kΩ","cmc":"7,6 %"},{"name":"1 MHz do 2 MHz","range":"od 1 kΩ do 2 kΩ","cmc":"3,7 %"},{"name":"2 MHz do 3 MHz","range":"od 1 kΩ do 2 kΩ","cmc":"4,4 %"},{"name":"3 MHz do 4 MHz","range":"od 1 kΩ do 2 kΩ","cmc":"5,1 %"},{"name":"4 MHz do 5 MHz","range":"od 1 kΩ do 2 kΩ","cmc":"5,8 %"},{"name":"5 MHz do 6 MHz","range":"od 1 kΩ do 2 kΩ","cmc":"8,7 %"},{"name":"1 MHz do 2 MHz","range":"od 2 kΩ do 3 kΩ","cmc":"4,4 %"},{"name":"2 MHz do 3 MHz","range":"od 2 kΩ do 3 kΩ","cmc":"5,2 %"},{"name":"3 MHz do 4 MHz","range":"od 2 kΩ do 3 kΩ","cmc":"6,1 %"},{"name":"4 MHz do 5 MHz","range":"od 2 kΩ do 3 kΩ","cmc":"7,0 %"},{"name":"1 MHz do 2 MHz","range":"od 3 kΩ do 4 kΩ","cmc":"5,1 %"},{"name":"2 MHz do 3 MHz","range":"od 3 kΩ do 4 kΩ","cmc":"6,1 %"},{"name":"3 MHz do 4 MHz","range":"od 3 kΩ do 4 kΩ","cmc":"7,1 %"},{"name":"4 MHz do 5 MHz","range":"od 3 kΩ do 4 kΩ","cmc":"8,1 %"},{"name":"1 MHz do 2 MHz","range":"od 4 kΩ do 5 kΩ","cmc":"5,8 %"},{"name":"2 MHz do 3 MHz","range":"od 4 kΩ do 5 kΩ","cmc":"7,0 %"},{"name":"3 MHz do 4 MHz","range":"od 4 kΩ do 5 kΩ","cmc":"8,1 %"},{"name":"4 MHz do 5 MHz","range":"od 4 kΩ do 5 kΩ","cmc":"9,3 %"},{"name":"1 MHz do 2 MHz","range":"od 5 kΩ do 7 kΩ","cmc":"7,3 %"},{"name":"2 MHz do 3 MHz","range":"od 5 kΩ do 7 kΩ","cmc":"8,7 %"},{"name":"1 MHz do 2 MHz","range":"od 7 kΩ do 9 kΩ","cmc":"8,7 %"},{"name":"1 MHz do 2 MHz","range":"od 9 kΩ do 10 kΩ","cmc":"9,4 %"}],"parameters_en":[{"name":"1 MHz to 2 MHz","range":"0,5 Ω to 0,6 Ω","cmc":"8,7 %"},{"name":"1 MHz to 2 MHz","range":"0,6 Ω to 0,7 Ω","cmc":"7,3 %"},{"name":"2 MHz to 3 MHz","range":"0,6 Ω to 0,7 Ω","cmc":"8,7 %"},{"name":"1 MHz to 2 MHz","range":"0,7 Ω to 0,8 Ω","cmc":"6,2 %"},{"name":"2 MHz to 3 MHz","range":"0,7 Ω to 0,8 Ω","cmc":"7,5 %"},{"name":"3 MHz to 4 MHz","range":"0,7 Ω to 0,8 Ω","cmc":"8,7 %"},{"name":"1 MHz to 2 MHz","range":"0,8 Ω to 0,9 Ω","cmc":"5,5 %"},{"name":"2 MHz to 3 MHz","range":"0,8 Ω to 0,9 Ω","cmc":"6,5 %"},{"name":"3 MHz to 4 MHz","range":"0,8 Ω to 0,9 Ω","cmc":"7,6 %"},{"name":"4 MHz to 5 MHz","range":"0,8 Ω to 0,9 Ω","cmc":"8,7 %"},{"name":"1 MHz to 2 MHz","range":"0,9 Ω to 1 Ω","cmc":"4,9 %"},{"name":"2 MHz to 3 MHz","range":"0,9 Ω to 1 Ω","cmc":"5,8 %"},{"name":"3 MHz to 4 MHz","range":"0,9 Ω to 1 Ω","cmc":"6,8 %"},{"name":"4 MHz to 5 MHz","range":"0,9 Ω to 1 Ω","cmc":"7,8 %"},{"name":"1 MHz to 2 MHz","range":"3 Ω to 4 Ω","cmc":"8,0 %"},{"name":"2 MHz to 3 MHz","range":"3 Ω to 4 Ω","cmc":"9,6 %"},{"name":"1 MHz to 2 MHz","range":"4 Ω to 5 Ω","cmc":"6,2 %"},{"name":"2 MHz to 3 MHz","range":"4 Ω to 5 Ω","cmc":"7,4 %"},{"name":"3 MHz to 4 MHz","range":"4 Ω to 5 Ω","cmc":"8,6 %"},{"name":"4 MHz to 5 MHz","range":"4 Ω to 5 Ω","cmc":"9,9 %"},{"name":"1 MHz to 2 MHz","range":"5 Ω to 6 Ω","cmc":"5,1 %"},{"name":"2 MHz to 3 MHz","range":"5 Ω to 6 Ω","cmc":"6,1 %"},{"name":"3 MHz to 4 MHz","range":"5 Ω to 6 Ω","cmc":"7,1 %"},{"name":"4 MHz to 5 MHz","range":"5 Ω to 6 Ω","cmc":"8,1 %"},{"name":"1 MHz to 2 MHz","range":"6 Ω to 7 Ω","cmc":"4,4 %"},{"name":"2 MHz to 3 MHz","range":"6 Ω to 7 Ω","cmc":"5,2 %"},{"name":"3 MHz to 4 MHz","range":"6 Ω to 7 Ω","cmc":"6,1 %"},{"name":"4 MHz to 5 MHz","range":"6 Ω to 7 Ω","cmc":"7,0 %"},{"name":"1 MHz to 2 MHz","range":"7 Ω to 8 Ω","cmc":"3,9 %"},{"name":"2 MHz to 3 MHz","range":"7 Ω to 8 Ω","cmc":"4,6 %"},{"name":"3 MHz to 4 MHz","range":"7 Ω to 8 Ω","cmc":"5,4 %"},{"name":"4 MHz to 5 MHz","range":"7 Ω to 8 Ω","cmc":"6,2 %"},{"name":"5 MHz to 6 MHz","range":"7 Ω to 8 Ω","cmc":"9,2 %"},{"name":"1 MHz to 2 MHz","range":"8 Ω to 9 Ω","cmc":"3,5 %"},{"name":"2 MHz to 3 MHz","range":"8 Ω to 9 Ω","cmc":"4,2 %"},{"name":"3 MHz to 4 MHz","range":"8 Ω to 9 Ω","cmc":"4,8 %"},{"name":"4 MHz to 5 MHz","range":"8 Ω to 9 Ω","cmc":"5,5 %"},{"name":"5 MHz to 6 MHz","range":"8 Ω to 9 Ω","cmc":"8,3 %"},{"name":"6 MHz to 7 MHz","range":"8 Ω to 9 Ω","cmc":"9,6 %"},{"name":"1 MHz to 2 MHz","range":"9 Ω to 10 Ω","cmc":"3,2 %"},{"name":"2 MHz to 3 MHz","range":"9 Ω to 10 Ω","cmc":"3,8 %"},{"name":"3 MHz to 4 MHz","range":"9 Ω to 10 Ω","cmc":"4,4 %"},{"name":"4 MHz to 5 MHz","range":"9 Ω to 10 Ω","cmc":"5,5 %"},{"name":"5 MHz to 6 MHz","range":"9 Ω to 10 Ω","cmc":"7,6 %"},{"name":"6 MHz to 7 MHz","range":"9 Ω to 10 Ω","cmc":"8,8 %"},{"name":"1 MHz to 2 MHz","range":"10 Ω to 20 Ω","cmc":"4,8 %"},{"name":"2 MHz to 3 MHz","range":"10 Ω to 20 Ω","cmc":"5,8 %"},{"name":"3 MHz to 4 MHz","range":"10 Ω to 20 Ω","cmc":"6,7 %"},{"name":"4 MHz to 5 MHz","range":"10 Ω to 20 Ω","cmc":"7,7 %"},{"name":"1 MHz to 2 MHz","range":"20 Ω to 30 Ω","cmc":"3,4 %"},{"name":"2 MHz to 3 MHz","range":"20 Ω to 30 Ω","cmc":"4,0 %"},{"name":"3 MHz to 4 MHz","range":"20 Ω to 30 Ω","cmc":"4,7 %"},{"name":"4 MHz to 5 MHz","range":"20 Ω to 30 Ω","cmc":"5,4 %"},{"name":"5 MHz to 6 MHz","range":"20 Ω to 30 Ω","cmc":"8,0 %"},{"name":"6 MHz to 7 MHz","range":"20 Ω to 30 Ω","cmc":"9,3 %"},{"name":"1 MHz to 2 MHz","range":"30 Ω to 50 Ω","cmc":"2,9 %"},{"name":"2 MHz to 3 MHz","range":"30 Ω to 50 Ω","cmc":"3,5 %"},{"name":"3 MHz to 4 MHz","range":"30 Ω to 50 Ω","cmc":"4,0 %"},{"name":"4 MHz to 5 MHz","range":"30 Ω to 50 Ω","cmc":"4,6 %"},{"name":"5 MHz to 6 MHz","range":"30 Ω to 50 Ω","cmc":"6,9 %"},{"name":"6 MHz to 7 MHz","range":"30 Ω to 50 Ω","cmc":"8,0 %"},{"name":"7 MHz to 8 MHz","range":"30 Ω to 50 Ω","cmc":"9,1 %"},{"name":"1 MHz to 2 MHz","range":"50 Ω to 100 Ω","cmc":"2,5 %"},{"name":"2 MHz to 3 MHz","range":"50 Ω to 100 Ω","cmc":"3,0 %"},{"name":"3 MHz to 4 MHz","range":"50 Ω to 100 Ω","cmc":"3,5 %"},{"name":"4 MHz to 5 MHz","range":"50 Ω to 100 Ω","cmc":"4,0 %"},{"name":"5 MHz to 6 MHz","range":"50 Ω to 100 Ω","cmc":"5,9 %"},{"name":"6 MHz to 7 MHz","range":"50 Ω to 100 Ω","cmc":"6,9 %"},{"name":"7 MHz to 8 MHz","range":"50 Ω to 100 Ω","cmc":"7,9 %"},{"name":"1 MHz to 2 MHz","range":"100 Ω to 300 Ω","cmc":"2,8 %"},{"name":"2 MHz to 3 MHz","range":"100 Ω to 300 Ω","cmc":"3,3 %"},{"name":"3 MHz to 4 MHz","range":"100 Ω to 300 Ω","cmc":"3,9 %"},{"name":"4 MHz to 5 MHz","range":"100 Ω to 300 Ω","cmc":"4,4 %"},{"name":"5 MHz to 6 MHz","range":"100 Ω to 300 Ω","cmc":"6,8 %"},{"name":"6 MHz to 7 MHz","range":"100 Ω to 300 Ω","cmc":"7,7 %"},{"name":"7 MHz to 8 MHz","range":"100 Ω to 300 Ω","cmc":"8,8 %"},{"name":"1 MHz to 2 MHz","range":"300 Ω to 500 Ω","cmc":"3,4 %"},{"name":"2 MHz to 3 MHz","range":"300 Ω to 500 Ω","cmc":"4,0 %"},{"name":"3 MHz to 4 MHz","range":"300 Ω to 500 Ω","cmc":"4,7 %"},{"name":"4 MHz to 5 MHz","range":"300 Ω to 500 Ω","cmc":"5,4 %"},{"name":"5 MHz to 6 MHz","range":"300 Ω to 500 Ω","cmc":"8,0 %"},{"name":"6 MHz to 7 MHz","range":"300 Ω to 500 Ω","cmc":"9,3 %"},{"name":"1 MHz to 2 MHz","range":"500 Ω to 700 Ω","cmc":"3,9 %"},{"name":"2 MHz to 3 MHz","range":"500 Ω to 700 Ω","cmc":"4,6 %"},{"name":"3 MHz to 4 MHz","range":"500 Ω to 700 Ω","cmc":"5,5 %"},{"name":"4 MHz to 5 MHz","range":"500 Ω to 700 Ω","cmc":"6,3 %"},{"name":"5 MHz to 6 MHz","range":"500 Ω to 700 Ω","cmc":"9,4 %"},{"name":"1 MHz to 2 MHz","range":"700 Ω to 1 kΩ","cmc":"4,8 %"},{"name":"2 MHz to 3 MHz","range":"700 Ω to 1 kΩ","cmc":"5,7 %"},{"name":"3 MHz to 4 MHz","range":"700 Ω to 1 kΩ","cmc":"6,7 %"},{"name":"4 MHz to 5 MHz","range":"700 Ω to 1 kΩ","cmc":"7,6 %"},{"name":"1 MHz to 2 MHz","range":"1 kΩ to 2 kΩ","cmc":"3,7 %"},{"name":"2 MHz to 3 MHz","range":"1 kΩ to 2 kΩ","cmc":"4,4 %"},{"name":"3 MHz to 4 MHz","range":"1 kΩ to 2 kΩ","cmc":"5,1 %"},{"name":"4 MHz to 5 MHz","range":"1 kΩ to 2 kΩ","cmc":"5,8 %"},{"name":"5 MHz to 6 MHz","range":"1 kΩ to 2 kΩ","cmc":"8,7 %"},{"name":"1 MHz to 2 MHz","range":"2 kΩ to 3 kΩ","cmc":"4,4 %"},{"name":"2 MHz to 3 MHz","range":"2 kΩ to 3 kΩ","cmc":"5,2 %"},{"name":"3 MHz to 4 MHz","range":"2 kΩ to 3 kΩ","cmc":"6,1 %"},{"name":"4 MHz to 5 MHz","range":"2 kΩ to 3 kΩ","cmc":"7,0 %"},{"name":"1 MHz to 2 MHz","range":"3 kΩ to 4 kΩ","cmc":"5,1 %"},{"name":"2 MHz to 3 MHz","range":"3 kΩ to 4 kΩ","cmc":"6,1 %"},{"name":"3 MHz to 4 MHz","range":"3 kΩ to 4 kΩ","cmc":"7,1 %"},{"name":"4 MHz to 5 MHz","range":"3 kΩ to 4 kΩ","cmc":"8,1 %"},{"name":"1 MHz to 2 MHz","range":"4 kΩ to 5 kΩ","cmc":"5,8 %"},{"name":"2 MHz to 3 MHz","range":"4 kΩ to 5 kΩ","cmc":"7,0 %"},{"name":"3 MHz to 4 MHz","range":"4 kΩ to 5 kΩ","cmc":"8,1 %"},{"name":"4 MHz to 5 MHz","range":"4 kΩ to 5 kΩ","cmc":"9,3 %"},{"name":"1 MHz to 2 MHz","range":"5 kΩ to 7 kΩ","cmc":"7,3 %"},{"name":"2 MHz to 3 MHz","range":"5 kΩ to 7 kΩ","cmc":"8,7 %"},{"name":"1 MHz to 2 MHz","range":"7 kΩ to 9 kΩ","cmc":"8,7 %"},{"name":"1 MHz to 2 MHz","range":"9 kΩ to 10 kΩ","cmc":"9,4 %"}],"parameters_zh":[{"name":"1 MHz 至 2 MHz","range":"0,5 Ω 至 0,6 Ω","cmc":"8,7 %"},{"name":"1 MHz 至 2 MHz","range":"0,6 Ω 至 0,7 Ω","cmc":"7,3 %"},{"name":"2 MHz 至 3 MHz","range":"0,6 Ω 至 0,7 Ω","cmc":"8,7 %"},{"name":"1 MHz 至 2 MHz","range":"0,7 Ω 至 0,8 Ω","cmc":"6,2 %"},{"name":"2 MHz 至 3 MHz","range":"0,7 Ω 至 0,8 Ω","cmc":"7,5 %"},{"name":"3 MHz 至 4 MHz","range":"0,7 Ω 至 0,8 Ω","cmc":"8,7 %"},{"name":"1 MHz 至 2 MHz","range":"0,8 Ω 至 0,9 Ω","cmc":"5,5 %"},{"name":"2 MHz 至 3 MHz","range":"0,8 Ω 至 0,9 Ω","cmc":"6,5 %"},{"name":"3 MHz 至 4 MHz","range":"0,8 Ω 至 0,9 Ω","cmc":"7,6 %"},{"name":"4 MHz 至 5 MHz","range":"0,8 Ω 至 0,9 Ω","cmc":"8,7 %"},{"name":"1 MHz 至 2 MHz","range":"0,9 Ω 至 1 Ω","cmc":"4,9 %"},{"name":"2 MHz 至 3 MHz","range":"0,9 Ω 至 1 Ω","cmc":"5,8 %"},{"name":"3 MHz 至 4 MHz","range":"0,9 Ω 至 1 Ω","cmc":"6,8 %"},{"name":"4 MHz 至 5 MHz","range":"0,9 Ω 至 1 Ω","cmc":"7,8 %"},{"name":"1 MHz 至 2 MHz","range":"3 Ω 至 4 Ω","cmc":"8,0 %"},{"name":"2 MHz 至 3 MHz","range":"3 Ω 至 4 Ω","cmc":"9,6 %"},{"name":"1 MHz 至 2 MHz","range":"4 Ω 至 5 Ω","cmc":"6,2 %"},{"name":"2 MHz 至 3 MHz","range":"4 Ω 至 5 Ω","cmc":"7,4 %"},{"name":"3 MHz 至 4 MHz","range":"4 Ω 至 5 Ω","cmc":"8,6 %"},{"name":"4 MHz 至 5 MHz","range":"4 Ω 至 5 Ω","cmc":"9,9 %"},{"name":"1 MHz 至 2 MHz","range":"5 Ω 至 6 Ω","cmc":"5,1 %"},{"name":"2 MHz 至 3 MHz","range":"5 Ω 至 6 Ω","cmc":"6,1 %"},{"name":"3 MHz 至 4 MHz","range":"5 Ω 至 6 Ω","cmc":"7,1 %"},{"name":"4 MHz 至 5 MHz","range":"5 Ω 至 6 Ω","cmc":"8,1 %"},{"name":"1 MHz 至 2 MHz","range":"6 Ω 至 7 Ω","cmc":"4,4 %"},{"name":"2 MHz 至 3 MHz","range":"6 Ω 至 7 Ω","cmc":"5,2 %"},{"name":"3 MHz 至 4 MHz","range":"6 Ω 至 7 Ω","cmc":"6,1 %"},{"name":"4 MHz 至 5 MHz","range":"6 Ω 至 7 Ω","cmc":"7,0 %"},{"name":"1 MHz 至 2 MHz","range":"7 Ω 至 8 Ω","cmc":"3,9 %"},{"name":"2 MHz 至 3 MHz","range":"7 Ω 至 8 Ω","cmc":"4,6 %"},{"name":"3 MHz 至 4 MHz","range":"7 Ω 至 8 Ω","cmc":"5,4 %"},{"name":"4 MHz 至 5 MHz","range":"7 Ω 至 8 Ω","cmc":"6,2 %"},{"name":"5 MHz 至 6 MHz","range":"7 Ω 至 8 Ω","cmc":"9,2 %"},{"name":"1 MHz 至 2 MHz","range":"8 Ω 至 9 Ω","cmc":"3,5 %"},{"name":"2 MHz 至 3 MHz","range":"8 Ω 至 9 Ω","cmc":"4,2 %"},{"name":"3 MHz 至 4 MHz","range":"8 Ω 至 9 Ω","cmc":"4,8 %"},{"name":"4 MHz 至 5 MHz","range":"8 Ω 至 9 Ω","cmc":"5,5 %"},{"name":"5 MHz 至 6 MHz","range":"8 Ω 至 9 Ω","cmc":"8,3 %"},{"name":"6 MHz 至 7 MHz","range":"8 Ω 至 9 Ω","cmc":"9,6 %"},{"name":"1 MHz 至 2 MHz","range":"9 Ω 至 10 Ω","cmc":"3,2 %"},{"name":"2 MHz 至 3 MHz","range":"9 Ω 至 10 Ω","cmc":"3,8 %"},{"name":"3 MHz 至 4 MHz","range":"9 Ω 至 10 Ω","cmc":"4,4 %"},{"name":"4 MHz 至 5 MHz","range":"9 Ω 至 10 Ω","cmc":"5,5 %"},{"name":"5 MHz 至 6 MHz","range":"9 Ω 至 10 Ω","cmc":"7,6 %"},{"name":"6 MHz 至 7 MHz","range":"9 Ω 至 10 Ω","cmc":"8,8 %"},{"name":"1 MHz 至 2 MHz","range":"10 Ω 至 20 Ω","cmc":"4,8 %"},{"name":"2 MHz 至 3 MHz","range":"10 Ω 至 20 Ω","cmc":"5,8 %"},{"name":"3 MHz 至 4 MHz","range":"10 Ω 至 20 Ω","cmc":"6,7 %"},{"name":"4 MHz 至 5 MHz","range":"10 Ω 至 20 Ω","cmc":"7,7 %"},{"name":"1 MHz 至 2 MHz","range":"20 Ω 至 30 Ω","cmc":"3,4 %"},{"name":"2 MHz 至 3 MHz","range":"20 Ω 至 30 Ω","cmc":"4,0 %"},{"name":"3 MHz 至 4 MHz","range":"20 Ω 至 30 Ω","cmc":"4,7 %"},{"name":"4 MHz 至 5 MHz","range":"20 Ω 至 30 Ω","cmc":"5,4 %"},{"name":"5 MHz 至 6 MHz","range":"20 Ω 至 30 Ω","cmc":"8,0 %"},{"name":"6 MHz 至 7 MHz","range":"20 Ω 至 30 Ω","cmc":"9,3 %"},{"name":"1 MHz 至 2 MHz","range":"30 Ω 至 50 Ω","cmc":"2,9 %"},{"name":"2 MHz 至 3 MHz","range":"30 Ω 至 50 Ω","cmc":"3,5 %"},{"name":"3 MHz 至 4 MHz","range":"30 Ω 至 50 Ω","cmc":"4,0 %"},{"name":"4 MHz 至 5 MHz","range":"30 Ω 至 50 Ω","cmc":"4,6 %"},{"name":"5 MHz 至 6 MHz","range":"30 Ω 至 50 Ω","cmc":"6,9 %"},{"name":"6 MHz 至 7 MHz","range":"30 Ω 至 50 Ω","cmc":"8,0 %"},{"name":"7 MHz 至 8 MHz","range":"30 Ω 至 50 Ω","cmc":"9,1 %"},{"name":"1 MHz 至 2 MHz","range":"50 Ω 至 100 Ω","cmc":"2,5 %"},{"name":"2 MHz 至 3 MHz","range":"50 Ω 至 100 Ω","cmc":"3,0 %"},{"name":"3 MHz 至 4 MHz","range":"50 Ω 至 100 Ω","cmc":"3,5 %"},{"name":"4 MHz 至 5 MHz","range":"50 Ω 至 100 Ω","cmc":"4,0 %"},{"name":"5 MHz 至 6 MHz","range":"50 Ω 至 100 Ω","cmc":"5,9 %"},{"name":"6 MHz 至 7 MHz","range":"50 Ω 至 100 Ω","cmc":"6,9 %"},{"name":"7 MHz 至 8 MHz","range":"50 Ω 至 100 Ω","cmc":"7,9 %"},{"name":"1 MHz 至 2 MHz","range":"100 Ω 至 300 Ω","cmc":"2,8 %"},{"name":"2 MHz 至 3 MHz","range":"100 Ω 至 300 Ω","cmc":"3,3 %"},{"name":"3 MHz 至 4 MHz","range":"100 Ω 至 300 Ω","cmc":"3,9 %"},{"name":"4 MHz 至 5 MHz","range":"100 Ω 至 300 Ω","cmc":"4,4 %"},{"name":"5 MHz 至 6 MHz","range":"100 Ω 至 300 Ω","cmc":"6,8 %"},{"name":"6 MHz 至 7 MHz","range":"100 Ω 至 300 Ω","cmc":"7,7 %"},{"name":"7 MHz 至 8 MHz","range":"100 Ω 至 300 Ω","cmc":"8,8 %"},{"name":"1 MHz 至 2 MHz","range":"300 Ω 至 500 Ω","cmc":"3,4 %"},{"name":"2 MHz 至 3 MHz","range":"300 Ω 至 500 Ω","cmc":"4,0 %"},{"name":"3 MHz 至 4 MHz","range":"300 Ω 至 500 Ω","cmc":"4,7 %"},{"name":"4 MHz 至 5 MHz","range":"300 Ω 至 500 Ω","cmc":"5,4 %"},{"name":"5 MHz 至 6 MHz","range":"300 Ω 至 500 Ω","cmc":"8,0 %"},{"name":"6 MHz 至 7 MHz","range":"300 Ω 至 500 Ω","cmc":"9,3 %"},{"name":"1 MHz 至 2 MHz","range":"500 Ω 至 700 Ω","cmc":"3,9 %"},{"name":"2 MHz 至 3 MHz","range":"500 Ω 至 700 Ω","cmc":"4,6 %"},{"name":"3 MHz 至 4 MHz","range":"500 Ω 至 700 Ω","cmc":"5,5 %"},{"name":"4 MHz 至 5 MHz","range":"500 Ω 至 700 Ω","cmc":"6,3 %"},{"name":"5 MHz 至 6 MHz","range":"500 Ω 至 700 Ω","cmc":"9,4 %"},{"name":"1 MHz 至 2 MHz","range":"700 Ω 至 1 kΩ","cmc":"4,8 %"},{"name":"2 MHz 至 3 MHz","range":"700 Ω 至 1 kΩ","cmc":"5,7 %"},{"name":"3 MHz 至 4 MHz","range":"700 Ω 至 1 kΩ","cmc":"6,7 %"},{"name":"4 MHz 至 5 MHz","range":"700 Ω 至 1 kΩ","cmc":"7,6 %"},{"name":"1 MHz 至 2 MHz","range":"1 kΩ 至 2 kΩ","cmc":"3,7 %"},{"name":"2 MHz 至 3 MHz","range":"1 kΩ 至 2 kΩ","cmc":"4,4 %"},{"name":"3 MHz 至 4 MHz","range":"1 kΩ 至 2 kΩ","cmc":"5,1 %"},{"name":"4 MHz 至 5 MHz","range":"1 kΩ 至 2 kΩ","cmc":"5,8 %"},{"name":"5 MHz 至 6 MHz","range":"1 kΩ 至 2 kΩ","cmc":"8,7 %"},{"name":"1 MHz 至 2 MHz","range":"2 kΩ 至 3 kΩ","cmc":"4,4 %"},{"name":"2 MHz 至 3 MHz","range":"2 kΩ 至 3 kΩ","cmc":"5,2 %"},{"name":"3 MHz 至 4 MHz","range":"2 kΩ 至 3 kΩ","cmc":"6,1 %"},{"name":"4 MHz 至 5 MHz","range":"2 kΩ 至 3 kΩ","cmc":"7,0 %"},{"name":"1 MHz 至 2 MHz","range":"3 kΩ 至 4 kΩ","cmc":"5,1 %"},{"name":"2 MHz 至 3 MHz","range":"3 kΩ 至 4 kΩ","cmc":"6,1 %"},{"name":"3 MHz 至 4 MHz","range":"3 kΩ 至 4 kΩ","cmc":"7,1 %"},{"name":"4 MHz 至 5 MHz","range":"3 kΩ 至 4 kΩ","cmc":"8,1 %"},{"name":"1 MHz 至 2 MHz","range":"4 kΩ 至 5 kΩ","cmc":"5,8 %"},{"name":"2 MHz 至 3 MHz","range":"4 kΩ 至 5 kΩ","cmc":"7,0 %"},{"name":"3 MHz 至 4 MHz","range":"4 kΩ 至 5 kΩ","cmc":"8,1 %"},{"name":"4 MHz 至 5 MHz","range":"4 kΩ 至 5 kΩ","cmc":"9,3 %"},{"name":"1 MHz 至 2 MHz","range":"5 kΩ 至 7 kΩ","cmc":"7,3 %"},{"name":"2 MHz 至 3 MHz","range":"5 kΩ 至 7 kΩ","cmc":"8,7 %"},{"name":"1 MHz 至 2 MHz","range":"7 kΩ 至 9 kΩ","cmc":"8,7 %"},{"name":"1 MHz 至 2 MHz","range":"9 kΩ 至 10 kΩ","cmc":"9,4 %"}],"parameters_cs":[{"name":"1 MHz až 2 MHz","range":"0,5 Ω až 0,6 Ω","cmc":"8,7 %"},{"name":"1 MHz až 2 MHz","range":"0,6 Ω až 0,7 Ω","cmc":"7,3 %"},{"name":"2 MHz až 3 MHz","range":"0,6 Ω až 0,7 Ω","cmc":"8,7 %"},{"name":"1 MHz až 2 MHz","range":"0,7 Ω až 0,8 Ω","cmc":"6,2 %"},{"name":"2 MHz až 3 MHz","range":"0,7 Ω až 0,8 Ω","cmc":"7,5 %"},{"name":"3 MHz až 4 MHz","range":"0,7 Ω až 0,8 Ω","cmc":"8,7 %"},{"name":"1 MHz až 2 MHz","range":"0,8 Ω až 0,9 Ω","cmc":"5,5 %"},{"name":"2 MHz až 3 MHz","range":"0,8 Ω až 0,9 Ω","cmc":"6,5 %"},{"name":"3 MHz až 4 MHz","range":"0,8 Ω až 0,9 Ω","cmc":"7,6 %"},{"name":"4 MHz až 5 MHz","range":"0,8 Ω až 0,9 Ω","cmc":"8,7 %"},{"name":"1 MHz až 2 MHz","range":"0,9 Ω až 1 Ω","cmc":"4,9 %"},{"name":"2 MHz až 3 MHz","range":"0,9 Ω až 1 Ω","cmc":"5,8 %"},{"name":"3 MHz až 4 MHz","range":"0,9 Ω až 1 Ω","cmc":"6,8 %"},{"name":"4 MHz až 5 MHz","range":"0,9 Ω až 1 Ω","cmc":"7,8 %"},{"name":"1 MHz až 2 MHz","range":"3 Ω až 4 Ω","cmc":"8,0 %"},{"name":"2 MHz až 3 MHz","range":"3 Ω až 4 Ω","cmc":"9,6 %"},{"name":"1 MHz až 2 MHz","range":"4 Ω až 5 Ω","cmc":"6,2 %"},{"name":"2 MHz až 3 MHz","range":"4 Ω až 5 Ω","cmc":"7,4 %"},{"name":"3 MHz až 4 MHz","range":"4 Ω až 5 Ω","cmc":"8,6 %"},{"name":"4 MHz až 5 MHz","range":"4 Ω až 5 Ω","cmc":"9,9 %"},{"name":"1 MHz až 2 MHz","range":"5 Ω až 6 Ω","cmc":"5,1 %"},{"name":"2 MHz až 3 MHz","range":"5 Ω až 6 Ω","cmc":"6,1 %"},{"name":"3 MHz až 4 MHz","range":"5 Ω až 6 Ω","cmc":"7,1 %"},{"name":"4 MHz až 5 MHz","range":"5 Ω až 6 Ω","cmc":"8,1 %"},{"name":"1 MHz až 2 MHz","range":"6 Ω až 7 Ω","cmc":"4,4 %"},{"name":"2 MHz až 3 MHz","range":"6 Ω až 7 Ω","cmc":"5,2 %"},{"name":"3 MHz až 4 MHz","range":"6 Ω až 7 Ω","cmc":"6,1 %"},{"name":"4 MHz až 5 MHz","range":"6 Ω až 7 Ω","cmc":"7,0 %"},{"name":"1 MHz až 2 MHz","range":"7 Ω až 8 Ω","cmc":"3,9 %"},{"name":"2 MHz až 3 MHz","range":"7 Ω až 8 Ω","cmc":"4,6 %"},{"name":"3 MHz až 4 MHz","range":"7 Ω až 8 Ω","cmc":"5,4 %"},{"name":"4 MHz až 5 MHz","range":"7 Ω až 8 Ω","cmc":"6,2 %"},{"name":"5 MHz až 6 MHz","range":"7 Ω až 8 Ω","cmc":"9,2 %"},{"name":"1 MHz až 2 MHz","range":"8 Ω až 9 Ω","cmc":"3,5 %"},{"name":"2 MHz až 3 MHz","range":"8 Ω až 9 Ω","cmc":"4,2 %"},{"name":"3 MHz až 4 MHz","range":"8 Ω až 9 Ω","cmc":"4,8 %"},{"name":"4 MHz až 5 MHz","range":"8 Ω až 9 Ω","cmc":"5,5 %"},{"name":"5 MHz až 6 MHz","range":"8 Ω až 9 Ω","cmc":"8,3 %"},{"name":"6 MHz až 7 MHz","range":"8 Ω až 9 Ω","cmc":"9,6 %"},{"name":"1 MHz až 2 MHz","range":"9 Ω až 10 Ω","cmc":"3,2 %"},{"name":"2 MHz až 3 MHz","range":"9 Ω až 10 Ω","cmc":"3,8 %"},{"name":"3 MHz až 4 MHz","range":"9 Ω až 10 Ω","cmc":"4,4 %"},{"name":"4 MHz až 5 MHz","range":"9 Ω až 10 Ω","cmc":"5,5 %"},{"name":"5 MHz až 6 MHz","range":"9 Ω až 10 Ω","cmc":"7,6 %"},{"name":"6 MHz až 7 MHz","range":"9 Ω až 10 Ω","cmc":"8,8 %"},{"name":"1 MHz až 2 MHz","range":"10 Ω až 20 Ω","cmc":"4,8 %"},{"name":"2 MHz až 3 MHz","range":"10 Ω až 20 Ω","cmc":"5,8 %"},{"name":"3 MHz až 4 MHz","range":"10 Ω až 20 Ω","cmc":"6,7 %"},{"name":"4 MHz až 5 MHz","range":"10 Ω až 20 Ω","cmc":"7,7 %"},{"name":"1 MHz až 2 MHz","range":"20 Ω až 30 Ω","cmc":"3,4 %"},{"name":"2 MHz až 3 MHz","range":"20 Ω až 30 Ω","cmc":"4,0 %"},{"name":"3 MHz až 4 MHz","range":"20 Ω až 30 Ω","cmc":"4,7 %"},{"name":"4 MHz až 5 MHz","range":"20 Ω až 30 Ω","cmc":"5,4 %"},{"name":"5 MHz až 6 MHz","range":"20 Ω až 30 Ω","cmc":"8,0 %"},{"name":"6 MHz až 7 MHz","range":"20 Ω až 30 Ω","cmc":"9,3 %"},{"name":"1 MHz až 2 MHz","range":"30 Ω až 50 Ω","cmc":"2,9 %"},{"name":"2 MHz až 3 MHz","range":"30 Ω až 50 Ω","cmc":"3,5 %"},{"name":"3 MHz až 4 MHz","range":"30 Ω až 50 Ω","cmc":"4,0 %"},{"name":"4 MHz až 5 MHz","range":"30 Ω až 50 Ω","cmc":"4,6 %"},{"name":"5 MHz až 6 MHz","range":"30 Ω až 50 Ω","cmc":"6,9 %"},{"name":"6 MHz až 7 MHz","range":"30 Ω až 50 Ω","cmc":"8,0 %"},{"name":"7 MHz až 8 MHz","range":"30 Ω až 50 Ω","cmc":"9,1 %"},{"name":"1 MHz až 2 MHz","range":"50 Ω až 100 Ω","cmc":"2,5 %"},{"name":"2 MHz až 3 MHz","range":"50 Ω až 100 Ω","cmc":"3,0 %"},{"name":"3 MHz až 4 MHz","range":"50 Ω až 100 Ω","cmc":"3,5 %"},{"name":"4 MHz až 5 MHz","range":"50 Ω až 100 Ω","cmc":"4,0 %"},{"name":"5 MHz až 6 MHz","range":"50 Ω až 100 Ω","cmc":"5,9 %"},{"name":"6 MHz až 7 MHz","range":"50 Ω až 100 Ω","cmc":"6,9 %"},{"name":"7 MHz až 8 MHz","range":"50 Ω až 100 Ω","cmc":"7,9 %"},{"name":"1 MHz až 2 MHz","range":"100 Ω až 300 Ω","cmc":"2,8 %"},{"name":"2 MHz až 3 MHz","range":"100 Ω až 300 Ω","cmc":"3,3 %"},{"name":"3 MHz až 4 MHz","range":"100 Ω až 300 Ω","cmc":"3,9 %"},{"name":"4 MHz až 5 MHz","range":"100 Ω až 300 Ω","cmc":"4,4 %"},{"name":"5 MHz až 6 MHz","range":"100 Ω až 300 Ω","cmc":"6,8 %"},{"name":"6 MHz až 7 MHz","range":"100 Ω až 300 Ω","cmc":"7,7 %"},{"name":"7 MHz až 8 MHz","range":"100 Ω až 300 Ω","cmc":"8,8 %"},{"name":"1 MHz až 2 MHz","range":"300 Ω až 500 Ω","cmc":"3,4 %"},{"name":"2 MHz až 3 MHz","range":"300 Ω až 500 Ω","cmc":"4,0 %"},{"name":"3 MHz až 4 MHz","range":"300 Ω až 500 Ω","cmc":"4,7 %"},{"name":"4 MHz až 5 MHz","range":"300 Ω až 500 Ω","cmc":"5,4 %"},{"name":"5 MHz až 6 MHz","range":"300 Ω až 500 Ω","cmc":"8,0 %"},{"name":"6 MHz až 7 MHz","range":"300 Ω až 500 Ω","cmc":"9,3 %"},{"name":"1 MHz až 2 MHz","range":"500 Ω až 700 Ω","cmc":"3,9 %"},{"name":"2 MHz až 3 MHz","range":"500 Ω až 700 Ω","cmc":"4,6 %"},{"name":"3 MHz až 4 MHz","range":"500 Ω až 700 Ω","cmc":"5,5 %"},{"name":"4 MHz až 5 MHz","range":"500 Ω až 700 Ω","cmc":"6,3 %"},{"name":"5 MHz až 6 MHz","range":"500 Ω až 700 Ω","cmc":"9,4 %"},{"name":"1 MHz až 2 MHz","range":"700 Ω až 1 kΩ","cmc":"4,8 %"},{"name":"2 MHz až 3 MHz","range":"700 Ω až 1 kΩ","cmc":"5,7 %"},{"name":"3 MHz až 4 MHz","range":"700 Ω až 1 kΩ","cmc":"6,7 %"},{"name":"4 MHz až 5 MHz","range":"700 Ω až 1 kΩ","cmc":"7,6 %"},{"name":"1 MHz až 2 MHz","range":"1 kΩ až 2 kΩ","cmc":"3,7 %"},{"name":"2 MHz až 3 MHz","range":"1 kΩ až 2 kΩ","cmc":"4,4 %"},{"name":"3 MHz až 4 MHz","range":"1 kΩ až 2 kΩ","cmc":"5,1 %"},{"name":"4 MHz až 5 MHz","range":"1 kΩ až 2 kΩ","cmc":"5,8 %"},{"name":"5 MHz až 6 MHz","range":"1 kΩ až 2 kΩ","cmc":"8,7 %"},{"name":"1 MHz až 2 MHz","range":"2 kΩ až 3 kΩ","cmc":"4,4 %"},{"name":"2 MHz až 3 MHz","range":"2 kΩ až 3 kΩ","cmc":"5,2 %"},{"name":"3 MHz až 4 MHz","range":"2 kΩ až 3 kΩ","cmc":"6,1 %"},{"name":"4 MHz až 5 MHz","range":"2 kΩ až 3 kΩ","cmc":"7,0 %"},{"name":"1 MHz až 2 MHz","range":"3 kΩ až 4 kΩ","cmc":"5,1 %"},{"name":"2 MHz až 3 MHz","range":"3 kΩ až 4 kΩ","cmc":"6,1 %"},{"name":"3 MHz až 4 MHz","range":"3 kΩ až 4 kΩ","cmc":"7,1 %"},{"name":"4 MHz až 5 MHz","range":"3 kΩ až 4 kΩ","cmc":"8,1 %"},{"name":"1 MHz až 2 MHz","range":"4 kΩ až 5 kΩ","cmc":"5,8 %"},{"name":"2 MHz až 3 MHz","range":"4 kΩ až 5 kΩ","cmc":"7,0 %"},{"name":"3 MHz až 4 MHz","range":"4 kΩ až 5 kΩ","cmc":"8,1 %"},{"name":"4 MHz až 5 MHz","range":"4 kΩ až 5 kΩ","cmc":"9,3 %"},{"name":"1 MHz až 2 MHz","range":"5 kΩ až 7 kΩ","cmc":"7,3 %"},{"name":"2 MHz až 3 MHz","range":"5 kΩ až 7 kΩ","cmc":"8,7 %"},{"name":"1 MHz až 2 MHz","range":"7 kΩ až 9 kΩ","cmc":"8,7 %"},{"name":"1 MHz až 2 MHz","range":"9 kΩ až 10 kΩ","cmc":"9,4 %"}],"technique":"Pomiar bezpośredni miernikiem LCR","technique_en":"Direct measurement by a LCR meter","technique_zh":"用 LCR 表直接测量","technique_cs":"Přímé měření LCR měřidlem","techniques":["Pomiar bezpośredni miernikiem LCR"],"techniques_en":["Direct measurement by a LCR meter"],"techniques_zh":["用 LCR 表直接测量"],"techniques_cs":["Přímé měření LCR měřidlem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 MHz do 2 MHz od 0,5 Ω do 0,6 Ω CMC 8,7 %\n1 MHz do 2 MHz od 0,6 Ω do 0,7 Ω CMC 7,3 %\n2 MHz do 3 MHz od 0,6 Ω do 0,7 Ω CMC 8,7 %\n1 MHz do 2 MHz od 0,7 Ω do 0,8 Ω CMC 6,2 %\n2 MHz do 3 MHz od 0,7 Ω do 0,8 Ω CMC 7,5 %\n3 MHz do 4 MHz od 0,7 Ω do 0,8 Ω CMC 8,7 %\n1 MHz do 2 MHz od 0,8 Ω do 0,9 Ω CMC 5,5 %\n2 MHz do 3 MHz od 0,8 Ω do 0,9 Ω CMC 6,5 %\n3 MHz do 4 MHz od 0,8 Ω do 0,9 Ω CMC 7,6 %\n4 MHz do 5 MHz od 0,8 Ω do 0,9 Ω CMC 8,7 %\n1 MHz do 2 MHz od 0,9 Ω do 1 Ω CMC 4,9 %\n2 MHz do 3 MHz od 0,9 Ω do 1 Ω CMC 5,8 %\n3 MHz do 4 MHz od 0,9 Ω do 1 Ω CMC 6,8 %\n4 MHz do 5 MHz od 0,9 Ω do 1 Ω CMC 7,8 %\n1 MHz do 2 MHz od 3 Ω do 4 Ω CMC 8,0 %\n2 MHz do 3 MHz od 3 Ω do 4 Ω CMC 9,6 %\n1 MHz do 2 MHz od 4 Ω do 5 Ω CMC 6,2 %\n2 MHz do 3 MHz od 4 Ω do 5 Ω CMC 7,4 %\n3 MHz do 4 MHz od 4 Ω do 5 Ω CMC 8,6 %\n4 MHz do 5 MHz od 4 Ω do 5 Ω CMC 9,9 %\n1 MHz do 2 MHz od 5 Ω do 6 Ω CMC 5,1 %\n2 MHz do 3 MHz od 5 Ω do 6 Ω CMC 6,1 %\n3 MHz do 4 MHz od 5 Ω do 6 Ω CMC 7,1 %\n4 MHz do 5 MHz od 5 Ω do 6 Ω CMC 8,1 %\n1 MHz do 2 MHz od 6 Ω do 7 Ω CMC 4,4 %\n2 MHz do 3 MHz od 6 Ω do 7 Ω CMC 5,2 %\n3 MHz do 4 MHz od 6 Ω do 7 Ω CMC 6,1 %\n4 MHz do 5 MHz od 6 Ω do 7 Ω CMC 7,0 %\n1 MHz do 2 MHz od 7 Ω do 8 Ω CMC 3,9 %\n2 MHz do 3 MHz od 7 Ω do 8 Ω CMC 4,6 %\n3 MHz do 4 MHz od 7 Ω do 8 Ω CMC 5,4 %\n4 MHz do 5 MHz od 7 Ω do 8 Ω CMC 6,2 %\n5 MHz do 6 MHz od 7 Ω do 8 Ω CMC 9,2 %\n1 MHz do 2 MHz od 8 Ω do 9 Ω CMC 3,5 %\n2 MHz do 3 MHz od 8 Ω do 9 Ω CMC 4,2 %\n3 MHz do 4 MHz od 8 Ω do 9 Ω CMC 4,8 %\n4 MHz do 5 MHz od 8 Ω do 9 Ω CMC 5,5 %\n5 MHz do 6 MHz od 8 Ω do 9 Ω CMC 8,3 %\n6 MHz do 7 MHz od 8 Ω do 9 Ω CMC 9,6 %\n1 MHz do 2 MHz od 9 Ω do 10 Ω CMC 3,2 %\n2 MHz do 3 MHz od 9 Ω do 10 Ω CMC 3,8 %\n3 MHz do 4 MHz od 9 Ω do 10 Ω CMC 4,4 %\n4 MHz do 5 MHz od 9 Ω do 10 Ω CMC 5,5 %\n5 MHz do 6 MHz od 9 Ω do 10 Ω CMC 7,6 %\n6 MHz do 7 MHz od 9 Ω do 10 Ω CMC 8,8 %\n1 MHz do 2 MHz od 10 Ω do 20 Ω CMC 4,8 %\n2 MHz do 3 MHz od 10 Ω do 20 Ω CMC 5,8 %\n3 MHz do 4 MHz od 10 Ω do 20 Ω CMC 6,7 %\n4 MHz do 5 MHz od 10 Ω do 20 Ω CMC 7,7 %\n1 MHz do 2 MHz od 20 Ω do 30 Ω CMC 3,4 %\n2 MHz do 3 MHz od 20 Ω do 30 Ω CMC 4,0 %\n3 MHz do 4 MHz od 20 Ω do 30 Ω CMC 4,7 %\n4 MHz do 5 MHz od 20 Ω do 30 Ω CMC 5,4 %\n5 MHz do 6 MHz od 20 Ω do 30 Ω CMC 8,0 %\n6 MHz do 7 MHz od 20 Ω do 30 Ω CMC 9,3 %\n1 MHz do 2 MHz od 30 Ω do 50 Ω CMC 2,9 %\n2 MHz do 3 MHz od 30 Ω do 50 Ω CMC 3,5 %\n3 MHz do 4 MHz od 30 Ω do 50 Ω CMC 4,0 %\n4 MHz do 5 MHz od 30 Ω do 50 Ω CMC 4,6 %\n5 MHz do 6 MHz od 30 Ω do 50 Ω CMC 6,9 %\n6 MHz do 7 MHz od 30 Ω do 50 Ω CMC 8,0 %\n7 MHz do 8 MHz od 30 Ω do 50 Ω CMC 9,1 %\n1 MHz do 2 MHz od 50 Ω do 100 Ω CMC 2,5 %\n2 MHz do 3 MHz od 50 Ω do 100 Ω CMC 3,0 %\n3 MHz do 4 MHz od 50 Ω do 100 Ω CMC 3,5 %\n4 MHz do 5 MHz od 50 Ω do 100 Ω CMC 4,0 %\n5 MHz do 6 MHz od 50 Ω do 100 Ω CMC 5,9 %\n6 MHz do 7 MHz od 50 Ω do 100 Ω CMC 6,9 %\n7 MHz do 8 MHz od 50 Ω do 100 Ω CMC 7,9 %\n1 MHz do 2 MHz od 100 Ω do 300 Ω CMC 2,8 %\n2 MHz do 3 MHz od 100 Ω do 300 Ω CMC 3,3 %\n3 MHz do 4 MHz od 100 Ω do 300 Ω CMC 3,9 %\n4 MHz do 5 MHz od 100 Ω do 300 Ω CMC 4,4 %\n5 MHz do 6 MHz od 100 Ω do 300 Ω CMC 6,8 %\n6 MHz do 7 MHz od 100 Ω do 300 Ω CMC 7,7 %\n7 MHz do 8 MHz od 100 Ω do 300 Ω CMC 8,8 %\n1 MHz do 2 MHz od 300 Ω do 500 Ω CMC 3,4 %\n2 MHz do 3 MHz od 300 Ω do 500 Ω CMC 4,0 %\n3 MHz do 4 MHz od 300 Ω do 500 Ω CMC 4,7 %\n4 MHz do 5 MHz od 300 Ω do 500 Ω CMC 5,4 %\n5 MHz do 6 MHz od 300 Ω do 500 Ω CMC 8,0 %\n6 MHz do 7 MHz od 300 Ω do 500 Ω CMC 9,3 %\n1 MHz do 2 MHz od 500 Ω do 700 Ω CMC 3,9 %\n2 MHz do 3 MHz od 500 Ω do 700 Ω CMC 4,6 %\n3 MHz do 4 MHz od 500 Ω do 700 Ω CMC 5,5 %\n4 MHz do 5 MHz od 500 Ω do 700 Ω CMC 6,3 %\n5 MHz do 6 MHz od 500 Ω do 700 Ω CMC 9,4 %\n1 MHz do 2 MHz od 700 Ω do 1 kΩ CMC 4,8 %\n2 MHz do 3 MHz od 700 Ω do 1 kΩ CMC 5,7 %\n3 MHz do 4 MHz od 700 Ω do 1 kΩ CMC 6,7 %\n4 MHz do 5 MHz od 700 Ω do 1 kΩ CMC 7,6 %\n1 MHz do 2 MHz od 1 kΩ do 2 kΩ CMC 3,7 %\n2 MHz do 3 MHz od 1 kΩ do 2 kΩ CMC 4,4 %\n3 MHz do 4 MHz od 1 kΩ do 2 kΩ CMC 5,1 %\n4 MHz do 5 MHz od 1 kΩ do 2 kΩ CMC 5,8 %\n5 MHz do 6 MHz od 1 kΩ do 2 kΩ CMC 8,7 %\n1 MHz do 2 MHz od 2 kΩ do 3 kΩ CMC 4,4 %\n2 MHz do 3 MHz od 2 kΩ do 3 kΩ CMC 5,2 %\n3 MHz do 4 MHz od 2 kΩ do 3 kΩ CMC 6,1 %\n4 MHz do 5 MHz od 2 kΩ do 3 kΩ CMC 7,0 %\n1 MHz do 2 MHz od 3 kΩ do 4 kΩ CMC 5,1 %\n2 MHz do 3 MHz od 3 kΩ do 4 kΩ CMC 6,1 %\n3 MHz do 4 MHz od 3 kΩ do 4 kΩ CMC 7,1 %\n4 MHz do 5 MHz od 3 kΩ do 4 kΩ CMC 8,1 %\n1 MHz do 2 MHz od 4 kΩ do 5 kΩ CMC 5,8 %\n2 MHz do 3 MHz od 4 kΩ do 5 kΩ CMC 7,0 %\n3 MHz do 4 MHz od 4 kΩ do 5 kΩ CMC 8,1 %\n4 MHz do 5 MHz od 4 kΩ do 5 kΩ CMC 9,3 %\n1 MHz do 2 MHz od 5 kΩ do 7 kΩ CMC 7,3 %\n2 MHz do 3 MHz od 5 kΩ do 7 kΩ CMC 8,7 %\n1 MHz do 2 MHz od 7 kΩ do 9 kΩ CMC 8,7 %\n1 MHz do 2 MHz od 9 kΩ do 10 kΩ CMC 9,4 %\nPomiar bezpośredni miernikiem LCR","reference":"TP6, TP24","norm_bases":["TP6","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie przemiennym / Wzorce rezystancji przy prądzie przemiennym dla częstotliwości od 1 MHz do 8 MHz Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem LCR 1 MHz do 2 MHz od 0,5 Ω do 0,6 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,6 Ω do 0,7 Ω CMC 7,3 % 2 MHz do 3 MHz od 0,6 Ω do 0,7 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,7 Ω do 0,8 Ω CMC 6,2 % 2 MHz do 3 MHz od 0,7 Ω do 0,8 Ω CMC 7,5 % 3 MHz do 4 MHz od 0,7 Ω do 0,8 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,8 Ω do 0,9 Ω CMC 5,5 % 2 MHz do 3 MHz od 0,8 Ω do 0,9 Ω CMC 6,5 % 3 MHz do 4 MHz od 0,8 Ω do 0,9 Ω CMC 7,6 % 4 MHz do 5 MHz od 0,8 Ω do 0,9 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,9 Ω do 1 Ω CMC 4,9 % 2 MHz do 3 MHz od 0,9 Ω do 1 Ω CMC 5,8 % 3 MHz do 4 MHz od 0,9 Ω do 1 Ω CMC 6,8 % 4 MHz do 5 MHz od 0,9 Ω do 1 Ω CMC 7,8 % 1 MHz do 2 MHz od 3 Ω do 4 Ω CMC 8,0 % 2 MHz do 3 MHz od 3 Ω do 4 Ω CMC 9,6 % 1 MHz do 2 MHz od 4 Ω do 5 Ω CMC 6,2 % 2 MHz do 3 MHz od 4 Ω do 5 Ω CMC 7,4 % 3 MHz do 4 MHz od 4 Ω do 5 Ω CMC 8,6 % 4 MHz do 5 MHz od 4 Ω do 5 Ω CMC 9,9 % 1 MHz do 2 MHz od 5 Ω do 6 Ω CMC 5,1 % 2 MHz do 3 MHz od 5 Ω do 6 Ω CMC 6,1 % 3 MHz do 4 MHz od 5 Ω do 6 Ω CMC 7,1 % 4 MHz do 5 MHz od 5 Ω do 6 Ω CMC 8,1 % 1 MHz do 2 MHz od 6 Ω do 7 Ω CMC 4,4 % 2 MHz do 3 MHz od 6 Ω do 7 Ω CMC 5,2 % 3 MHz do 4 MHz od 6 Ω do 7 Ω CMC 6,1 % 4 MHz do 5 MHz od 6 Ω do 7 Ω CMC 7,0 % 1 MHz do 2 MHz od 7 Ω do 8 Ω CMC 3,9 % 2 MHz do 3 MHz od 7 Ω do 8 Ω CMC 4,6 % 3 MHz do 4 MHz od 7 Ω do 8 Ω CMC 5,4 % 4 MHz do 5 MHz od 7 Ω do 8 Ω CMC 6,2 % 5 MHz do 6 MHz od 7 Ω do 8 Ω CMC 9,2 % 1 MHz do 2 MHz od 8 Ω do 9 Ω CMC 3,5 % 2 MHz do 3 MHz od 8 Ω do 9 Ω CMC 4,2 % 3 MHz do 4 MHz od 8 Ω do 9 Ω CMC 4,8 % 4 MHz do 5 MHz od 8 Ω do 9 Ω CMC 5,5 % 5 MHz do 6 MHz od 8 Ω do 9 Ω CMC 8,3 % 6 MHz do 7 MHz od 8 Ω do 9 Ω CMC 9,6 % 1 MHz do 2 MHz od 9 Ω do 10 Ω CMC 3,2 % 2 MHz do 3 MHz od 9 Ω do 10 Ω CMC 3,8 % 3 MHz do 4 MHz od 9 Ω do 10 Ω CMC 4,4 % 4 MHz do 5 MHz od 9 Ω do 10 Ω CMC 5,5 % 5 MHz do 6 MHz od 9 Ω do 10 Ω CMC 7,6 % 6 MHz do 7 MHz od 9 Ω do 10 Ω CMC 8,8 % 1 MHz do 2 MHz od 10 Ω do 20 Ω CMC 4,8 % 2 MHz do 3 MHz od 10 Ω do 20 Ω CMC 5,8 % 3 MHz do 4 MHz od 10 Ω do 20 Ω CMC 6,7 % 4 MHz do 5 MHz od 10 Ω do 20 Ω CMC 7,7 % 1 MHz do 2 MHz od 20 Ω do 30 Ω CMC 3,4 % 2 MHz do 3 MHz od 20 Ω do 30 Ω CMC 4,0 % 3 MHz do 4 MHz od 20 Ω do 30 Ω CMC 4,7 % 4 MHz do 5 MHz od 20 Ω do 30 Ω CMC 5,4 % 5 MHz do 6 MHz od 20 Ω do 30 Ω CMC 8,0 % 6 MHz do 7 MHz od 20 Ω do 30 Ω CMC 9,3 % 1 MHz do 2 MHz od 30 Ω do 50 Ω CMC 2,9 % 2 MHz do 3 MHz od 30 Ω do 50 Ω CMC 3,5 % 3 MHz do 4 MHz od 30 Ω do 50 Ω CMC 4,0 % 4 MHz do 5 MHz od 30 Ω do 50 Ω CMC 4,6 % 5 MHz do 6 MHz od 30 Ω do 50 Ω CMC 6,9 % 6 MHz do 7 MHz od 30 Ω do 50 Ω CMC 8,0 % 7 MHz do 8 MHz od 30 Ω do 50 Ω CMC 9,1 % 1 MHz do 2 MHz od 50 Ω do 100 Ω CMC 2,5 % 2 MHz do 3 MHz od 50 Ω do 100 Ω CMC 3,0 % 3 MHz do 4 MHz od 50 Ω do 100 Ω CMC 3,5 % 4 MHz do 5 MHz od 50 Ω do 100 Ω CMC 4,0 % 5 MHz do 6 MHz od 50 Ω do 100 Ω CMC 5,9 % 6 MHz do 7 MHz od 50 Ω do 100 Ω CMC 6,9 % 7 MHz do 8 MHz od 50 Ω do 100 Ω CMC 7,9 % 1 MHz do 2 MHz od 100 Ω do 300 Ω CMC 2,8 % 2 MHz do 3 MHz od 100 Ω do 300 Ω CMC 3,3 % 3 MHz do 4 MHz od 100 Ω do 300 Ω CMC 3,9 % 4 MHz do 5 MHz od 100 Ω do 300 Ω CMC 4,4 % 5 MHz do 6 MHz od 100 Ω do 300 Ω CMC 6,8 % 6 MHz do 7 MHz od 100 Ω do 300 Ω CMC 7,7 % 7 MHz do 8 MHz od 100 Ω do 300 Ω CMC 8,8 % 1 MHz do 2 MHz od 300 Ω do 500 Ω CMC 3,4 % 2 MHz do 3 MHz od 300 Ω do 500 Ω CMC 4,0 % 3 MHz do 4 MHz od 300 Ω do 500 Ω CMC 4,7 % 4 MHz do 5 MHz od 300 Ω do 500 Ω CMC 5,4 % 5 MHz do 6 MHz od 300 Ω do 500 Ω CMC 8,0 % 6 MHz do 7 MHz od 300 Ω do 500 Ω CMC 9,3 % 1 MHz do 2 MHz od 500 Ω do 700 Ω CMC 3,9 % 2 MHz do 3 MHz od 500 Ω do 700 Ω CMC 4,6 % 3 MHz do 4 MHz od 500 Ω do 700 Ω CMC 5,5 % 4 MHz do 5 MHz od 500 Ω do 700 Ω CMC 6,3 % 5 MHz do 6 MHz od 500 Ω do 700 Ω CMC 9,4 % 1 MHz do 2 MHz od 700 Ω do 1 kΩ CMC 4,8 % 2 MHz do 3 MHz od 700 Ω do 1 kΩ CMC 5,7 % 3 MHz do 4 MHz od 700 Ω do 1 kΩ CMC 6,7 % 4 MHz do 5 MHz od 700 Ω do 1 kΩ CMC 7,6 % 1 MHz do 2 MHz od 1 kΩ do 2 kΩ CMC 3,7 % 2 MHz do 3 MHz od 1 kΩ do 2 kΩ CMC 4,4 % 3 MHz do 4 MHz od 1 kΩ do 2 kΩ CMC 5,1 % 4 MHz do 5 MHz od 1 kΩ do 2 kΩ CMC 5,8 % 5 MHz do 6 MHz od 1 kΩ do 2 kΩ CMC 8,7 % 1 MHz do 2 MHz od 2 kΩ do 3 kΩ CMC 4,4 % 2 MHz do 3 MHz od 2 kΩ do 3 kΩ CMC 5,2 % 3 MHz do 4 MHz od 2 kΩ do 3 kΩ CMC 6,1 % 4 MHz do 5 MHz od 2 kΩ do 3 kΩ CMC 7,0 % 1 MHz do 2 MHz od 3 kΩ do 4 kΩ CMC 5,1 % 2 MHz do 3 MHz od 3 kΩ do 4 kΩ CMC 6,1 % 3 MHz do 4 MHz od 3 kΩ do 4 kΩ CMC 7,1 % 4 MHz do 5 MHz od 3 kΩ do 4 kΩ CMC 8,1 % 1 MHz do 2 MHz od 4 kΩ do 5 kΩ CMC 5,8 % 2 MHz do 3 MHz od 4 kΩ do 5 kΩ CMC 7,0 % 3 MHz do 4 MHz od 4 kΩ do 5 kΩ CMC 8,1 % 4 MHz do 5 MHz od 4 kΩ do 5 kΩ CMC 9,3 % 1 MHz do 2 MHz od 5 kΩ do 7 kΩ CMC 7,3 % 2 MHz do 3 MHz od 5 kΩ do 7 kΩ CMC 8,7 % 1 MHz do 2 MHz od 7 kΩ do 9 kΩ CMC 8,7 % 1 MHz do 2 MHz od 9 kΩ do 10 kΩ CMC 9,4 % Střídavý odpor / Etalony střídavého odporu pro kmitočty 1 MHz až 8 MHz Kalibrace – elektrické veličiny Přímé měření LCR měřidlem 1 MHz až 2 MHz 0,5 Ω až 0,6 Ω CMC 8,7 % 1 MHz až 2 MHz 0,6 Ω až 0,7 Ω CMC 7,3 % 2 MHz až 3 MHz 0,6 Ω až 0,7 Ω CMC 8,7 % 1 MHz až 2 MHz 0,7 Ω až 0,8 Ω CMC 6,2 % 2 MHz až 3 MHz 0,7 Ω až 0,8 Ω CMC 7,5 % 3 MHz až 4 MHz 0,7 Ω až 0,8 Ω CMC 8,7 % 1 MHz až 2 MHz 0,8 Ω až 0,9 Ω CMC 5,5 % 2 MHz až 3 MHz 0,8 Ω až 0,9 Ω CMC 6,5 % 3 MHz až 4 MHz 0,8 Ω až 0,9 Ω CMC 7,6 % 4 MHz až 5 MHz 0,8 Ω až 0,9 Ω CMC 8,7 % 1 MHz až 2 MHz 0,9 Ω až 1 Ω CMC 4,9 % 2 MHz až 3 MHz 0,9 Ω až 1 Ω CMC 5,8 % 3 MHz až 4 MHz 0,9 Ω až 1 Ω CMC 6,8 % 4 MHz až 5 MHz 0,9 Ω až 1 Ω CMC 7,8 % 1 MHz až 2 MHz 3 Ω až 4 Ω CMC 8,0 % 2 MHz až 3 MHz 3 Ω až 4 Ω CMC 9,6 % 1 MHz až 2 MHz 4 Ω až 5 Ω CMC 6,2 % 2 MHz až 3 MHz 4 Ω až 5 Ω CMC 7,4 % 3 MHz až 4 MHz 4 Ω až 5 Ω CMC 8,6 % 4 MHz až 5 MHz 4 Ω až 5 Ω CMC 9,9 % 1 MHz až 2 MHz 5 Ω až 6 Ω CMC 5,1 % 2 MHz až 3 MHz 5 Ω až 6 Ω CMC 6,1 % 3 MHz až 4 MHz 5 Ω až 6 Ω CMC 7,1 % 4 MHz až 5 MHz 5 Ω až 6 Ω CMC 8,1 % 1 MHz až 2 MHz 6 Ω až 7 Ω CMC 4,4 % 2 MHz až 3 MHz 6 Ω až 7 Ω CMC 5,2 % 3 MHz až 4 MHz 6 Ω až 7 Ω CMC 6,1 % 4 MHz až 5 MHz 6 Ω až 7 Ω CMC 7,0 % 1 MHz až 2 MHz 7 Ω až 8 Ω CMC 3,9 % 2 MHz až 3 MHz 7 Ω až 8 Ω CMC 4,6 % 3 MHz až 4 MHz 7 Ω až 8 Ω CMC 5,4 % 4 MHz až 5 MHz 7 Ω až 8 Ω CMC 6,2 % 5 MHz až 6 MHz 7 Ω až 8 Ω CMC 9,2 % 1 MHz až 2 MHz 8 Ω až 9 Ω CMC 3,5 % 2 MHz až 3 MHz 8 Ω až 9 Ω CMC 4,2 % 3 MHz až 4 MHz 8 Ω až 9 Ω CMC 4,8 % 4 MHz až 5 MHz 8 Ω až 9 Ω CMC 5,5 % 5 MHz až 6 MHz 8 Ω až 9 Ω CMC 8,3 % 6 MHz až 7 MHz 8 Ω až 9 Ω CMC 9,6 % 1 MHz až 2 MHz 9 Ω až 10 Ω CMC 3,2 % 2 MHz až 3 MHz 9 Ω až 10 Ω CMC 3,8 % 3 MHz až 4 MHz 9 Ω až 10 Ω CMC 4,4 % 4 MHz až 5 MHz 9 Ω až 10 Ω CMC 5,5 % 5 MHz až 6 MHz 9 Ω až 10 Ω CMC 7,6 % 6 MHz až 7 MHz 9 Ω až 10 Ω CMC 8,8 % 1 MHz až 2 MHz 10 Ω až 20 Ω CMC 4,8 % 2 MHz až 3 MHz 10 Ω až 20 Ω CMC 5,8 % 3 MHz až 4 MHz 10 Ω až 20 Ω CMC 6,7 % 4 MHz až 5 MHz 10 Ω až 20 Ω CMC 7,7 % 1 MHz až 2 MHz 20 Ω až 30 Ω CMC 3,4 % 2 MHz až 3 MHz 20 Ω až 30 Ω CMC 4,0 % 3 MHz až 4 MHz 20 Ω až 30 Ω CMC 4,7 % 4 MHz až 5 MHz 20 Ω až 30 Ω CMC 5,4 % 5 MHz až 6 MHz 20 Ω až 30 Ω CMC 8,0 % 6 MHz až 7 MHz 20 Ω až 30 Ω CMC 9,3 % 1 MHz až 2 MHz 30 Ω až 50 Ω CMC 2,9 % 2 MHz až 3 MHz 30 Ω až 50 Ω CMC 3,5 % 3 MHz až 4 MHz 30 Ω až 50 Ω CMC 4,0 % 4 MHz až 5 MHz 30 Ω až 50 Ω CMC 4,6 % 5 MHz až 6 MHz 30 Ω až 50 Ω CMC 6,9 % 6 MHz až 7 MHz 30 Ω až 50 Ω CMC 8,0 % 7 MHz až 8 MHz 30 Ω až 50 Ω CMC 9,1 % 1 MHz až 2 MHz 50 Ω až 100 Ω CMC 2,5 % 2 MHz až 3 MHz 50 Ω až 100 Ω CMC 3,0 % 3 MHz až 4 MHz 50 Ω až 100 Ω CMC 3,5 % 4 MHz až 5 MHz 50 Ω až 100 Ω CMC 4,0 % 5 MHz až 6 MHz 50 Ω až 100 Ω CMC 5,9 % 6 MHz až 7 MHz 50 Ω až 100 Ω CMC 6,9 % 7 MHz až 8 MHz 50 Ω až 100 Ω CMC 7,9 % 1 MHz až 2 MHz 100 Ω až 300 Ω CMC 2,8 % 2 MHz až 3 MHz 100 Ω až 300 Ω CMC 3,3 % 3 MHz až 4 MHz 100 Ω až 300 Ω CMC 3,9 % 4 MHz až 5 MHz 100 Ω až 300 Ω CMC 4,4 % 5 MHz až 6 MHz 100 Ω až 300 Ω CMC 6,8 % 6 MHz až 7 MHz 100 Ω až 300 Ω CMC 7,7 % 7 MHz až 8 MHz 100 Ω až 300 Ω CMC 8,8 % 1 MHz až 2 MHz 300 Ω až 500 Ω CMC 3,4 % 2 MHz až 3 MHz 300 Ω až 500 Ω CMC 4,0 % 3 MHz až 4 MHz 300 Ω až 500 Ω CMC 4,7 % 4 MHz až 5 MHz 300 Ω až 500 Ω CMC 5,4 % 5 MHz až 6 MHz 300 Ω až 500 Ω CMC 8,0 % 6 MHz až 7 MHz 300 Ω až 500 Ω CMC 9,3 % 1 MHz až 2 MHz 500 Ω až 700 Ω CMC 3,9 % 2 MHz až 3 MHz 500 Ω až 700 Ω CMC 4,6 % 3 MHz až 4 MHz 500 Ω až 700 Ω CMC 5,5 % 4 MHz až 5 MHz 500 Ω až 700 Ω CMC 6,3 % 5 MHz až 6 MHz 500 Ω až 700 Ω CMC 9,4 % 1 MHz až 2 MHz 700 Ω až 1 kΩ CMC 4,8 % 2 MHz až 3 MHz 700 Ω až 1 kΩ CMC 5,7 % 3 MHz až 4 MHz 700 Ω až 1 kΩ CMC 6,7 % 4 MHz až 5 MHz 700 Ω až 1 kΩ CMC 7,6 % 1 MHz až 2 MHz 1 kΩ až 2 kΩ CMC 3,7 % 2 MHz až 3 MHz 1 kΩ až 2 kΩ CMC 4,4 % 3 MHz až 4 MHz 1 kΩ až 2 kΩ CMC 5,1 % 4 MHz až 5 MHz 1 kΩ až 2 kΩ CMC 5,8 % 5 MHz až 6 MHz 1 kΩ až 2 kΩ CMC 8,7 % 1 MHz až 2 MHz 2 kΩ až 3 kΩ CMC 4,4 % 2 MHz až 3 MHz 2 kΩ až 3 kΩ CMC 5,2 % 3 MHz až 4 MHz 2 kΩ až 3 kΩ CMC 6,1 % 4 MHz až 5 MHz 2 kΩ až 3 kΩ CMC 7,0 % 1 MHz až 2 MHz 3 kΩ až 4 kΩ CMC 5,1 % 2 MHz až 3 MHz 3 kΩ až 4 kΩ CMC 6,1 % 3 MHz až 4 MHz 3 kΩ až 4 kΩ CMC 7,1 % 4 MHz až 5 MHz 3 kΩ až 4 kΩ CMC 8,1 % 1 MHz až 2 MHz 4 kΩ až 5 kΩ CMC 5,8 % 2 MHz až 3 MHz 4 kΩ až 5 kΩ CMC 7,0 % 3 MHz až 4 MHz 4 kΩ až 5 kΩ CMC 8,1 % 4 MHz až 5 MHz 4 kΩ až 5 kΩ CMC 9,3 % 1 MHz až 2 MHz 5 kΩ až 7 kΩ CMC 7,3 % 2 MHz až 3 MHz 5 kΩ až 7 kΩ CMC 8,7 % 1 MHz až 2 MHz 7 kΩ až 9 kΩ CMC 8,7 % 1 MHz až 2 MHz 9 kΩ až 10 kΩ CMC 9,4 % TP6, TP24 Rezystancja przy pradzie przemiennym / Wzorce rezystancji przy pradzie przemiennym dla czestotliwosci od 1 MHz do 8 MHz Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem LCR 1 MHz do 2 MHz od 0,5 Ω do 0,6 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,6 Ω do 0,7 Ω CMC 7,3 % 2 MHz do 3 MHz od 0,6 Ω do 0,7 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,7 Ω do 0,8 Ω CMC 6,2 % 2 MHz do 3 MHz od 0,7 Ω do 0,8 Ω CMC 7,5 % 3 MHz do 4 MHz od 0,7 Ω do 0,8 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,8 Ω do 0,9 Ω CMC 5,5 % 2 MHz do 3 MHz od 0,8 Ω do 0,9 Ω CMC 6,5 % 3 MHz do 4 MHz od 0,8 Ω do 0,9 Ω CMC 7,6 % 4 MHz do 5 MHz od 0,8 Ω do 0,9 Ω CMC 8,7 % 1 MHz do 2 MHz od 0,9 Ω do 1 Ω CMC 4,9 % 2 MHz do 3 MHz od 0,9 Ω do 1 Ω CMC 5,8 % 3 MHz do 4 MHz od 0,9 Ω do 1 Ω CMC 6,8 % 4 MHz do 5 MHz od 0,9 Ω do 1 Ω CMC 7,8 % 1 MHz do 2 MHz od 3 Ω do 4 Ω CMC 8,0 % 2 MHz do 3 MHz od 3 Ω do 4 Ω CMC 9,6 % 1 MHz do 2 MHz od 4 Ω do 5 Ω CMC 6,2 % 2 MHz do 3 MHz od 4 Ω do 5 Ω CMC 7,4 % 3 MHz do 4 MHz od 4 Ω do 5 Ω CMC 8,6 % 4 MHz do 5 MHz od 4 Ω do 5 Ω CMC 9,9 % 1 MHz do 2 MHz od 5 Ω do 6 Ω CMC 5,1 % 2 MHz do 3 MHz od 5 Ω do 6 Ω CMC 6,1 % 3 MHz do 4 MHz od 5 Ω do 6 Ω CMC 7,1 % 4 MHz do 5 MHz od 5 Ω do 6 Ω CMC 8,1 % 1 MHz do 2 MHz od 6 Ω do 7 Ω CMC 4,4 % 2 MHz do 3 MHz od 6 Ω do 7 Ω CMC 5,2 % 3 MHz do 4 MHz od 6 Ω do 7 Ω CMC 6,1 % 4 MHz do 5 MHz od 6 Ω do 7 Ω CMC 7,0 % 1 MHz do 2 MHz od 7 Ω do 8 Ω CMC 3,9 % 2 MHz do 3 MHz od 7 Ω do 8 Ω CMC 4,6 % 3 MHz do 4 MHz od 7 Ω do 8 Ω CMC 5,4 % 4 MHz do 5 MHz od 7 Ω do 8 Ω CMC 6,2 % 5 MHz do 6 MHz od 7 Ω do 8 Ω CMC 9,2 % 1 MHz do 2 MHz od 8 Ω do 9 Ω CMC 3,5 % 2 MHz do 3 MHz od 8 Ω do 9 Ω CMC 4,2 % 3 MHz do 4 MHz od 8 Ω do 9 Ω CMC 4,8 % 4 MHz do 5 MHz od 8 Ω do 9 Ω CMC 5,5 % 5 MHz do 6 MHz od 8 Ω do 9 Ω CMC 8,3 % 6 MHz do 7 MHz od 8 Ω do 9 Ω CMC 9,6 % 1 MHz do 2 MHz od 9 Ω do 10 Ω CMC 3,2 % 2 MHz do 3 MHz od 9 Ω do 10 Ω CMC 3,8 % 3 MHz do 4 MHz od 9 Ω do 10 Ω CMC 4,4 % 4 MHz do 5 MHz od 9 Ω do 10 Ω CMC 5,5 % 5 MHz do 6 MHz od 9 Ω do 10 Ω CMC 7,6 % 6 MHz do 7 MHz od 9 Ω do 10 Ω CMC 8,8 % 1 MHz do 2 MHz od 10 Ω do 20 Ω CMC 4,8 % 2 MHz do 3 MHz od 10 Ω do 20 Ω CMC 5,8 % 3 MHz do 4 MHz od 10 Ω do 20 Ω CMC 6,7 % 4 MHz do 5 MHz od 10 Ω do 20 Ω CMC 7,7 % 1 MHz do 2 MHz od 20 Ω do 30 Ω CMC 3,4 % 2 MHz do 3 MHz od 20 Ω do 30 Ω CMC 4,0 % 3 MHz do 4 MHz od 20 Ω do 30 Ω CMC 4,7 % 4 MHz do 5 MHz od 20 Ω do 30 Ω CMC 5,4 % 5 MHz do 6 MHz od 20 Ω do 30 Ω CMC 8,0 % 6 MHz do 7 MHz od 20 Ω do 30 Ω CMC 9,3 % 1 MHz do 2 MHz od 30 Ω do 50 Ω CMC 2,9 % 2 MHz do 3 MHz od 30 Ω do 50 Ω CMC 3,5 % 3 MHz do 4 MHz od 30 Ω do 50 Ω CMC 4,0 % 4 MHz do 5 MHz od 30 Ω do 50 Ω CMC 4,6 % 5 MHz do 6 MHz od 30 Ω do 50 Ω CMC 6,9 % 6 MHz do 7 MHz od 30 Ω do 50 Ω CMC 8,0 % 7 MHz do 8 MHz od 30 Ω do 50 Ω CMC 9,1 % 1 MHz do 2 MHz od 50 Ω do 100 Ω CMC 2,5 % 2 MHz do 3 MHz od 50 Ω do 100 Ω CMC 3,0 % 3 MHz do 4 MHz od 50 Ω do 100 Ω CMC 3,5 % 4 MHz do 5 MHz od 50 Ω do 100 Ω CMC 4,0 % 5 MHz do 6 MHz od 50 Ω do 100 Ω CMC 5,9 % 6 MHz do 7 MHz od 50 Ω do 100 Ω CMC 6,9 % 7 MHz do 8 MHz od 50 Ω do 100 Ω CMC 7,9 % 1 MHz do 2 MHz od 100 Ω do 300 Ω CMC 2,8 % 2 MHz do 3 MHz od 100 Ω do 300 Ω CMC 3,3 % 3 MHz do 4 MHz od 100 Ω do 300 Ω CMC 3,9 % 4 MHz do 5 MHz od 100 Ω do 300 Ω CMC 4,4 % 5 MHz do 6 MHz od 100 Ω do 300 Ω CMC 6,8 % 6 MHz do 7 MHz od 100 Ω do 300 Ω CMC 7,7 % 7 MHz do 8 MHz od 100 Ω do 300 Ω CMC 8,8 % 1 MHz do 2 MHz od 300 Ω do 500 Ω CMC 3,4 % 2 MHz do 3 MHz od 300 Ω do 500 Ω CMC 4,0 % 3 MHz do 4 MHz od 300 Ω do 500 Ω CMC 4,7 % 4 MHz do 5 MHz od 300 Ω do 500 Ω CMC 5,4 % 5 MHz do 6 MHz od 300 Ω do 500 Ω CMC 8,0 % 6 MHz do 7 MHz od 300 Ω do 500 Ω CMC 9,3 % 1 MHz do 2 MHz od 500 Ω do 700 Ω CMC 3,9 % 2 MHz do 3 MHz od 500 Ω do 700 Ω CMC 4,6 % 3 MHz do 4 MHz od 500 Ω do 700 Ω CMC 5,5 % 4 MHz do 5 MHz od 500 Ω do 700 Ω CMC 6,3 % 5 MHz do 6 MHz od 500 Ω do 700 Ω CMC 9,4 % 1 MHz do 2 MHz od 700 Ω do 1 kΩ CMC 4,8 % 2 MHz do 3 MHz od 700 Ω do 1 kΩ CMC 5,7 % 3 MHz do 4 MHz od 700 Ω do 1 kΩ CMC 6,7 % 4 MHz do 5 MHz od 700 Ω do 1 kΩ CMC 7,6 % 1 MHz do 2 MHz od 1 kΩ do 2 kΩ CMC 3,7 % 2 MHz do 3 MHz od 1 kΩ do 2 kΩ CMC 4,4 % 3 MHz do 4 MHz od 1 kΩ do 2 kΩ CMC 5,1 % 4 MHz do 5 MHz od 1 kΩ do 2 kΩ CMC 5,8 % 5 MHz do 6 MHz od 1 kΩ do 2 kΩ CMC 8,7 % 1 MHz do 2 MHz od 2 kΩ do 3 kΩ CMC 4,4 % 2 MHz do 3 MHz od 2 kΩ do 3 kΩ CMC 5,2 % 3 MHz do 4 MHz od 2 kΩ do 3 kΩ CMC 6,1 % 4 MHz do 5 MHz od 2 kΩ do 3 kΩ CMC 7,0 % 1 MHz do 2 MHz od 3 kΩ do 4 kΩ CMC 5,1 % 2 MHz do 3 MHz od 3 kΩ do 4 kΩ CMC 6,1 % 3 MHz do 4 MHz od 3 kΩ do 4 kΩ CMC 7,1 % 4 MHz do 5 MHz od 3 kΩ do 4 kΩ CMC 8,1 % 1 MHz do 2 MHz od 4 kΩ do 5 kΩ CMC 5,8 % 2 MHz do 3 MHz od 4 kΩ do 5 kΩ CMC 7,0 % 3 MHz do 4 MHz od 4 kΩ do 5 kΩ CMC 8,1 % 4 MHz do 5 MHz od 4 kΩ do 5 kΩ CMC 9,3 % 1 MHz do 2 MHz od 5 kΩ do 7 kΩ CMC 7,3 % 2 MHz do 3 MHz od 5 kΩ do 7 kΩ CMC 8,7 % 1 MHz do 2 MHz od 7 kΩ do 9 kΩ CMC 8,7 % 1 MHz do 2 MHz od 9 kΩ do 10 kΩ CMC 9,4 % Stridavy odpor / Etalony stridaveho odporu pro kmitocty 1 MHz az 8 MHz Kalibrace – elektricke veliciny Prime mereni LCR meridlem 1 MHz az 2 MHz 0,5 Ω az 0,6 Ω CMC 8,7 % 1 MHz az 2 MHz 0,6 Ω az 0,7 Ω CMC 7,3 % 2 MHz az 3 MHz 0,6 Ω az 0,7 Ω CMC 8,7 % 1 MHz az 2 MHz 0,7 Ω az 0,8 Ω CMC 6,2 % 2 MHz az 3 MHz 0,7 Ω az 0,8 Ω CMC 7,5 % 3 MHz az 4 MHz 0,7 Ω az 0,8 Ω CMC 8,7 % 1 MHz az 2 MHz 0,8 Ω az 0,9 Ω CMC 5,5 % 2 MHz az 3 MHz 0,8 Ω az 0,9 Ω CMC 6,5 % 3 MHz az 4 MHz 0,8 Ω az 0,9 Ω CMC 7,6 % 4 MHz az 5 MHz 0,8 Ω az 0,9 Ω CMC 8,7 % 1 MHz az 2 MHz 0,9 Ω az 1 Ω CMC 4,9 % 2 MHz az 3 MHz 0,9 Ω az 1 Ω CMC 5,8 % 3 MHz az 4 MHz 0,9 Ω az 1 Ω CMC 6,8 % 4 MHz az 5 MHz 0,9 Ω az 1 Ω CMC 7,8 % 1 MHz az 2 MHz 3 Ω az 4 Ω CMC 8,0 % 2 MHz az 3 MHz 3 Ω az 4 Ω CMC 9,6 % 1 MHz az 2 MHz 4 Ω az 5 Ω CMC 6,2 % 2 MHz az 3 MHz 4 Ω az 5 Ω CMC 7,4 % 3 MHz az 4 MHz 4 Ω az 5 Ω CMC 8,6 % 4 MHz az 5 MHz 4 Ω az 5 Ω CMC 9,9 % 1 MHz az 2 MHz 5 Ω az 6 Ω CMC 5,1 % 2 MHz az 3 MHz 5 Ω az 6 Ω CMC 6,1 % 3 MHz az 4 MHz 5 Ω az 6 Ω CMC 7,1 % 4 MHz az 5 MHz 5 Ω az 6 Ω CMC 8,1 % 1 MHz az 2 MHz 6 Ω az 7 Ω CMC 4,4 % 2 MHz az 3 MHz 6 Ω az 7 Ω CMC 5,2 % 3 MHz az 4 MHz 6 Ω az 7 Ω CMC 6,1 % 4 MHz az 5 MHz 6 Ω az 7 Ω CMC 7,0 % 1 MHz az 2 MHz 7 Ω az 8 Ω CMC 3,9 % 2 MHz az 3 MHz 7 Ω az 8 Ω CMC 4,6 % 3 MHz az 4 MHz 7 Ω az 8 Ω CMC 5,4 % 4 MHz az 5 MHz 7 Ω az 8 Ω CMC 6,2 % 5 MHz az 6 MHz 7 Ω az 8 Ω CMC 9,2 % 1 MHz az 2 MHz 8 Ω az 9 Ω CMC 3,5 % 2 MHz az 3 MHz 8 Ω az 9 Ω CMC 4,2 % 3 MHz az 4 MHz 8 Ω az 9 Ω CMC 4,8 % 4 MHz az 5 MHz 8 Ω az 9 Ω CMC 5,5 % 5 MHz az 6 MHz 8 Ω az 9 Ω CMC 8,3 % 6 MHz az 7 MHz 8 Ω az 9 Ω CMC 9,6 % 1 MHz az 2 MHz 9 Ω az 10 Ω CMC 3,2 % 2 MHz az 3 MHz 9 Ω az 10 Ω CMC 3,8 % 3 MHz az 4 MHz 9 Ω az 10 Ω CMC 4,4 % 4 MHz az 5 MHz 9 Ω az 10 Ω CMC 5,5 % 5 MHz az 6 MHz 9 Ω az 10 Ω CMC 7,6 % 6 MHz az 7 MHz 9 Ω az 10 Ω CMC 8,8 % 1 MHz az 2 MHz 10 Ω az 20 Ω CMC 4,8 % 2 MHz az 3 MHz 10 Ω az 20 Ω CMC 5,8 % 3 MHz az 4 MHz 10 Ω az 20 Ω CMC 6,7 % 4 MHz az 5 MHz 10 Ω az 20 Ω CMC 7,7 % 1 MHz az 2 MHz 20 Ω az 30 Ω CMC 3,4 % 2 MHz az 3 MHz 20 Ω az 30 Ω CMC 4,0 % 3 MHz az 4 MHz 20 Ω az 30 Ω CMC 4,7 % 4 MHz az 5 MHz 20 Ω az 30 Ω CMC 5,4 % 5 MHz az 6 MHz 20 Ω az 30 Ω CMC 8,0 % 6 MHz az 7 MHz 20 Ω az 30 Ω CMC 9,3 % 1 MHz az 2 MHz 30 Ω az 50 Ω CMC 2,9 % 2 MHz az 3 MHz 30 Ω az 50 Ω CMC 3,5 % 3 MHz az 4 MHz 30 Ω az 50 Ω CMC 4,0 % 4 MHz az 5 MHz 30 Ω az 50 Ω CMC 4,6 % 5 MHz az 6 MHz 30 Ω az 50 Ω CMC 6,9 % 6 MHz az 7 MHz 30 Ω az 50 Ω CMC 8,0 % 7 MHz az 8 MHz 30 Ω az 50 Ω CMC 9,1 % 1 MHz az 2 MHz 50 Ω az 100 Ω CMC 2,5 % 2 MHz az 3 MHz 50 Ω az 100 Ω CMC 3,0 % 3 MHz az 4 MHz 50 Ω az 100 Ω CMC 3,5 % 4 MHz az 5 MHz 50 Ω az 100 Ω CMC 4,0 % 5 MHz az 6 MHz 50 Ω az 100 Ω CMC 5,9 % 6 MHz az 7 MHz 50 Ω az 100 Ω CMC 6,9 % 7 MHz az 8 MHz 50 Ω az 100 Ω CMC 7,9 % 1 MHz az 2 MHz 100 Ω az 300 Ω CMC 2,8 % 2 MHz az 3 MHz 100 Ω az 300 Ω CMC 3,3 % 3 MHz az 4 MHz 100 Ω az 300 Ω CMC 3,9 % 4 MHz az 5 MHz 100 Ω az 300 Ω CMC 4,4 % 5 MHz az 6 MHz 100 Ω az 300 Ω CMC 6,8 % 6 MHz az 7 MHz 100 Ω az 300 Ω CMC 7,7 % 7 MHz az 8 MHz 100 Ω az 300 Ω CMC 8,8 % 1 MHz az 2 MHz 300 Ω az 500 Ω CMC 3,4 % 2 MHz az 3 MHz 300 Ω az 500 Ω CMC 4,0 % 3 MHz az 4 MHz 300 Ω az 500 Ω CMC 4,7 % 4 MHz az 5 MHz 300 Ω az 500 Ω CMC 5,4 % 5 MHz az 6 MHz 300 Ω az 500 Ω CMC 8,0 % 6 MHz az 7 MHz 300 Ω az 500 Ω CMC 9,3 % 1 MHz az 2 MHz 500 Ω az 700 Ω CMC 3,9 % 2 MHz az 3 MHz 500 Ω az 700 Ω CMC 4,6 % 3 MHz az 4 MHz 500 Ω az 700 Ω CMC 5,5 % 4 MHz az 5 MHz 500 Ω az 700 Ω CMC 6,3 % 5 MHz az 6 MHz 500 Ω az 700 Ω CMC 9,4 % 1 MHz az 2 MHz 700 Ω az 1 kΩ CMC 4,8 % 2 MHz az 3 MHz 700 Ω az 1 kΩ CMC 5,7 % 3 MHz az 4 MHz 700 Ω az 1 kΩ CMC 6,7 % 4 MHz az 5 MHz 700 Ω az 1 kΩ CMC 7,6 % 1 MHz az 2 MHz 1 kΩ az 2 kΩ CMC 3,7 % 2 MHz az 3 MHz 1 kΩ az 2 kΩ CMC 4,4 % 3 MHz az 4 MHz 1 kΩ az 2 kΩ CMC 5,1 % 4 MHz az 5 MHz 1 kΩ az 2 kΩ CMC 5,8 % 5 MHz az 6 MHz 1 kΩ az 2 kΩ CMC 8,7 % 1 MHz az 2 MHz 2 kΩ az 3 kΩ CMC 4,4 % 2 MHz az 3 MHz 2 kΩ az 3 kΩ CMC 5,2 % 3 MHz az 4 MHz 2 kΩ az 3 kΩ CMC 6,1 % 4 MHz az 5 MHz 2 kΩ az 3 kΩ CMC 7,0 % 1 MHz az 2 MHz 3 kΩ az 4 kΩ CMC 5,1 % 2 MHz az 3 MHz 3 kΩ az 4 kΩ CMC 6,1 % 3 MHz az 4 MHz 3 kΩ az 4 kΩ CMC 7,1 % 4 MHz az 5 MHz 3 kΩ az 4 kΩ CMC 8,1 % 1 MHz az 2 MHz 4 kΩ az 5 kΩ CMC 5,8 % 2 MHz az 3 MHz 4 kΩ az 5 kΩ CMC 7,0 % 3 MHz az 4 MHz 4 kΩ az 5 kΩ CMC 8,1 % 4 MHz az 5 MHz 4 kΩ az 5 kΩ CMC 9,3 % 1 MHz az 2 MHz 5 kΩ az 7 kΩ CMC 7,3 % 2 MHz az 3 MHz 5 kΩ az 7 kΩ CMC 8,7 % 1 MHz az 2 MHz 7 kΩ az 9 kΩ CMC 8,7 % 1 MHz az 2 MHz 9 kΩ az 10 kΩ CMC 9,4 % TP6, TP24","search_en":"AC resistance / AC resistance standards for frequencies from 1 MHz to 8 MHz Calibration – electrical quantities Direct measurement by a LCR meter 1 MHz to 2 MHz 0,5 Ω to 0,6 Ω CMC 8,7 % 1 MHz to 2 MHz 0,6 Ω to 0,7 Ω CMC 7,3 % 2 MHz to 3 MHz 0,6 Ω to 0,7 Ω CMC 8,7 % 1 MHz to 2 MHz 0,7 Ω to 0,8 Ω CMC 6,2 % 2 MHz to 3 MHz 0,7 Ω to 0,8 Ω CMC 7,5 % 3 MHz to 4 MHz 0,7 Ω to 0,8 Ω CMC 8,7 % 1 MHz to 2 MHz 0,8 Ω to 0,9 Ω CMC 5,5 % 2 MHz to 3 MHz 0,8 Ω to 0,9 Ω CMC 6,5 % 3 MHz to 4 MHz 0,8 Ω to 0,9 Ω CMC 7,6 % 4 MHz to 5 MHz 0,8 Ω to 0,9 Ω CMC 8,7 % 1 MHz to 2 MHz 0,9 Ω to 1 Ω CMC 4,9 % 2 MHz to 3 MHz 0,9 Ω to 1 Ω CMC 5,8 % 3 MHz to 4 MHz 0,9 Ω to 1 Ω CMC 6,8 % 4 MHz to 5 MHz 0,9 Ω to 1 Ω CMC 7,8 % 1 MHz to 2 MHz 3 Ω to 4 Ω CMC 8,0 % 2 MHz to 3 MHz 3 Ω to 4 Ω CMC 9,6 % 1 MHz to 2 MHz 4 Ω to 5 Ω CMC 6,2 % 2 MHz to 3 MHz 4 Ω to 5 Ω CMC 7,4 % 3 MHz to 4 MHz 4 Ω to 5 Ω CMC 8,6 % 4 MHz to 5 MHz 4 Ω to 5 Ω CMC 9,9 % 1 MHz to 2 MHz 5 Ω to 6 Ω CMC 5,1 % 2 MHz to 3 MHz 5 Ω to 6 Ω CMC 6,1 % 3 MHz to 4 MHz 5 Ω to 6 Ω CMC 7,1 % 4 MHz to 5 MHz 5 Ω to 6 Ω CMC 8,1 % 1 MHz to 2 MHz 6 Ω to 7 Ω CMC 4,4 % 2 MHz to 3 MHz 6 Ω to 7 Ω CMC 5,2 % 3 MHz to 4 MHz 6 Ω to 7 Ω CMC 6,1 % 4 MHz to 5 MHz 6 Ω to 7 Ω CMC 7,0 % 1 MHz to 2 MHz 7 Ω to 8 Ω CMC 3,9 % 2 MHz to 3 MHz 7 Ω to 8 Ω CMC 4,6 % 3 MHz to 4 MHz 7 Ω to 8 Ω CMC 5,4 % 4 MHz to 5 MHz 7 Ω to 8 Ω CMC 6,2 % 5 MHz to 6 MHz 7 Ω to 8 Ω CMC 9,2 % 1 MHz to 2 MHz 8 Ω to 9 Ω CMC 3,5 % 2 MHz to 3 MHz 8 Ω to 9 Ω CMC 4,2 % 3 MHz to 4 MHz 8 Ω to 9 Ω CMC 4,8 % 4 MHz to 5 MHz 8 Ω to 9 Ω CMC 5,5 % 5 MHz to 6 MHz 8 Ω to 9 Ω CMC 8,3 % 6 MHz to 7 MHz 8 Ω to 9 Ω CMC 9,6 % 1 MHz to 2 MHz 9 Ω to 10 Ω CMC 3,2 % 2 MHz to 3 MHz 9 Ω to 10 Ω CMC 3,8 % 3 MHz to 4 MHz 9 Ω to 10 Ω CMC 4,4 % 4 MHz to 5 MHz 9 Ω to 10 Ω CMC 5,5 % 5 MHz to 6 MHz 9 Ω to 10 Ω CMC 7,6 % 6 MHz to 7 MHz 9 Ω to 10 Ω CMC 8,8 % 1 MHz to 2 MHz 10 Ω to 20 Ω CMC 4,8 % 2 MHz to 3 MHz 10 Ω to 20 Ω CMC 5,8 % 3 MHz to 4 MHz 10 Ω to 20 Ω CMC 6,7 % 4 MHz to 5 MHz 10 Ω to 20 Ω CMC 7,7 % 1 MHz to 2 MHz 20 Ω to 30 Ω CMC 3,4 % 2 MHz to 3 MHz 20 Ω to 30 Ω CMC 4,0 % 3 MHz to 4 MHz 20 Ω to 30 Ω CMC 4,7 % 4 MHz to 5 MHz 20 Ω to 30 Ω CMC 5,4 % 5 MHz to 6 MHz 20 Ω to 30 Ω CMC 8,0 % 6 MHz to 7 MHz 20 Ω to 30 Ω CMC 9,3 % 1 MHz to 2 MHz 30 Ω to 50 Ω CMC 2,9 % 2 MHz to 3 MHz 30 Ω to 50 Ω CMC 3,5 % 3 MHz to 4 MHz 30 Ω to 50 Ω CMC 4,0 % 4 MHz to 5 MHz 30 Ω to 50 Ω CMC 4,6 % 5 MHz to 6 MHz 30 Ω to 50 Ω CMC 6,9 % 6 MHz to 7 MHz 30 Ω to 50 Ω CMC 8,0 % 7 MHz to 8 MHz 30 Ω to 50 Ω CMC 9,1 % 1 MHz to 2 MHz 50 Ω to 100 Ω CMC 2,5 % 2 MHz to 3 MHz 50 Ω to 100 Ω CMC 3,0 % 3 MHz to 4 MHz 50 Ω to 100 Ω CMC 3,5 % 4 MHz to 5 MHz 50 Ω to 100 Ω CMC 4,0 % 5 MHz to 6 MHz 50 Ω to 100 Ω CMC 5,9 % 6 MHz to 7 MHz 50 Ω to 100 Ω CMC 6,9 % 7 MHz to 8 MHz 50 Ω to 100 Ω CMC 7,9 % 1 MHz to 2 MHz 100 Ω to 300 Ω CMC 2,8 % 2 MHz to 3 MHz 100 Ω to 300 Ω CMC 3,3 % 3 MHz to 4 MHz 100 Ω to 300 Ω CMC 3,9 % 4 MHz to 5 MHz 100 Ω to 300 Ω CMC 4,4 % 5 MHz to 6 MHz 100 Ω to 300 Ω CMC 6,8 % 6 MHz to 7 MHz 100 Ω to 300 Ω CMC 7,7 % 7 MHz to 8 MHz 100 Ω to 300 Ω CMC 8,8 % 1 MHz to 2 MHz 300 Ω to 500 Ω CMC 3,4 % 2 MHz to 3 MHz 300 Ω to 500 Ω CMC 4,0 % 3 MHz to 4 MHz 300 Ω to 500 Ω CMC 4,7 % 4 MHz to 5 MHz 300 Ω to 500 Ω CMC 5,4 % 5 MHz to 6 MHz 300 Ω to 500 Ω CMC 8,0 % 6 MHz to 7 MHz 300 Ω to 500 Ω CMC 9,3 % 1 MHz to 2 MHz 500 Ω to 700 Ω CMC 3,9 % 2 MHz to 3 MHz 500 Ω to 700 Ω CMC 4,6 % 3 MHz to 4 MHz 500 Ω to 700 Ω CMC 5,5 % 4 MHz to 5 MHz 500 Ω to 700 Ω CMC 6,3 % 5 MHz to 6 MHz 500 Ω to 700 Ω CMC 9,4 % 1 MHz to 2 MHz 700 Ω to 1 kΩ CMC 4,8 % 2 MHz to 3 MHz 700 Ω to 1 kΩ CMC 5,7 % 3 MHz to 4 MHz 700 Ω to 1 kΩ CMC 6,7 % 4 MHz to 5 MHz 700 Ω to 1 kΩ CMC 7,6 % 1 MHz to 2 MHz 1 kΩ to 2 kΩ CMC 3,7 % 2 MHz to 3 MHz 1 kΩ to 2 kΩ CMC 4,4 % 3 MHz to 4 MHz 1 kΩ to 2 kΩ CMC 5,1 % 4 MHz to 5 MHz 1 kΩ to 2 kΩ CMC 5,8 % 5 MHz to 6 MHz 1 kΩ to 2 kΩ CMC 8,7 % 1 MHz to 2 MHz 2 kΩ to 3 kΩ CMC 4,4 % 2 MHz to 3 MHz 2 kΩ to 3 kΩ CMC 5,2 % 3 MHz to 4 MHz 2 kΩ to 3 kΩ CMC 6,1 % 4 MHz to 5 MHz 2 kΩ to 3 kΩ CMC 7,0 % 1 MHz to 2 MHz 3 kΩ to 4 kΩ CMC 5,1 % 2 MHz to 3 MHz 3 kΩ to 4 kΩ CMC 6,1 % 3 MHz to 4 MHz 3 kΩ to 4 kΩ CMC 7,1 % 4 MHz to 5 MHz 3 kΩ to 4 kΩ CMC 8,1 % 1 MHz to 2 MHz 4 kΩ to 5 kΩ CMC 5,8 % 2 MHz to 3 MHz 4 kΩ to 5 kΩ CMC 7,0 % 3 MHz to 4 MHz 4 kΩ to 5 kΩ CMC 8,1 % 4 MHz to 5 MHz 4 kΩ to 5 kΩ CMC 9,3 % 1 MHz to 2 MHz 5 kΩ to 7 kΩ CMC 7,3 % 2 MHz to 3 MHz 5 kΩ to 7 kΩ CMC 8,7 % 1 MHz to 2 MHz 7 kΩ to 9 kΩ CMC 8,7 % 1 MHz to 2 MHz 9 kΩ to 10 kΩ CMC 9,4 % TP6, TP24","search_zh":"交流电阻 / 频率 1 MHz 至 8 MHz 的交流电阻标准器 校准 – 电学量 用 LCR 表直接测量 1 MHz 至 2 MHz 0,5 Ω 至 0,6 Ω CMC 8,7 % 1 MHz 至 2 MHz 0,6 Ω 至 0,7 Ω CMC 7,3 % 2 MHz 至 3 MHz 0,6 Ω 至 0,7 Ω CMC 8,7 % 1 MHz 至 2 MHz 0,7 Ω 至 0,8 Ω CMC 6,2 % 2 MHz 至 3 MHz 0,7 Ω 至 0,8 Ω CMC 7,5 % 3 MHz 至 4 MHz 0,7 Ω 至 0,8 Ω CMC 8,7 % 1 MHz 至 2 MHz 0,8 Ω 至 0,9 Ω CMC 5,5 % 2 MHz 至 3 MHz 0,8 Ω 至 0,9 Ω CMC 6,5 % 3 MHz 至 4 MHz 0,8 Ω 至 0,9 Ω CMC 7,6 % 4 MHz 至 5 MHz 0,8 Ω 至 0,9 Ω CMC 8,7 % 1 MHz 至 2 MHz 0,9 Ω 至 1 Ω CMC 4,9 % 2 MHz 至 3 MHz 0,9 Ω 至 1 Ω CMC 5,8 % 3 MHz 至 4 MHz 0,9 Ω 至 1 Ω CMC 6,8 % 4 MHz 至 5 MHz 0,9 Ω 至 1 Ω CMC 7,8 % 1 MHz 至 2 MHz 3 Ω 至 4 Ω CMC 8,0 % 2 MHz 至 3 MHz 3 Ω 至 4 Ω CMC 9,6 % 1 MHz 至 2 MHz 4 Ω 至 5 Ω CMC 6,2 % 2 MHz 至 3 MHz 4 Ω 至 5 Ω CMC 7,4 % 3 MHz 至 4 MHz 4 Ω 至 5 Ω CMC 8,6 % 4 MHz 至 5 MHz 4 Ω 至 5 Ω CMC 9,9 % 1 MHz 至 2 MHz 5 Ω 至 6 Ω CMC 5,1 % 2 MHz 至 3 MHz 5 Ω 至 6 Ω CMC 6,1 % 3 MHz 至 4 MHz 5 Ω 至 6 Ω CMC 7,1 % 4 MHz 至 5 MHz 5 Ω 至 6 Ω CMC 8,1 % 1 MHz 至 2 MHz 6 Ω 至 7 Ω CMC 4,4 % 2 MHz 至 3 MHz 6 Ω 至 7 Ω CMC 5,2 % 3 MHz 至 4 MHz 6 Ω 至 7 Ω CMC 6,1 % 4 MHz 至 5 MHz 6 Ω 至 7 Ω CMC 7,0 % 1 MHz 至 2 MHz 7 Ω 至 8 Ω CMC 3,9 % 2 MHz 至 3 MHz 7 Ω 至 8 Ω CMC 4,6 % 3 MHz 至 4 MHz 7 Ω 至 8 Ω CMC 5,4 % 4 MHz 至 5 MHz 7 Ω 至 8 Ω CMC 6,2 % 5 MHz 至 6 MHz 7 Ω 至 8 Ω CMC 9,2 % 1 MHz 至 2 MHz 8 Ω 至 9 Ω CMC 3,5 % 2 MHz 至 3 MHz 8 Ω 至 9 Ω CMC 4,2 % 3 MHz 至 4 MHz 8 Ω 至 9 Ω CMC 4,8 % 4 MHz 至 5 MHz 8 Ω 至 9 Ω CMC 5,5 % 5 MHz 至 6 MHz 8 Ω 至 9 Ω CMC 8,3 % 6 MHz 至 7 MHz 8 Ω 至 9 Ω CMC 9,6 % 1 MHz 至 2 MHz 9 Ω 至 10 Ω CMC 3,2 % 2 MHz 至 3 MHz 9 Ω 至 10 Ω CMC 3,8 % 3 MHz 至 4 MHz 9 Ω 至 10 Ω CMC 4,4 % 4 MHz 至 5 MHz 9 Ω 至 10 Ω CMC 5,5 % 5 MHz 至 6 MHz 9 Ω 至 10 Ω CMC 7,6 % 6 MHz 至 7 MHz 9 Ω 至 10 Ω CMC 8,8 % 1 MHz 至 2 MHz 10 Ω 至 20 Ω CMC 4,8 % 2 MHz 至 3 MHz 10 Ω 至 20 Ω CMC 5,8 % 3 MHz 至 4 MHz 10 Ω 至 20 Ω CMC 6,7 % 4 MHz 至 5 MHz 10 Ω 至 20 Ω CMC 7,7 % 1 MHz 至 2 MHz 20 Ω 至 30 Ω CMC 3,4 % 2 MHz 至 3 MHz 20 Ω 至 30 Ω CMC 4,0 % 3 MHz 至 4 MHz 20 Ω 至 30 Ω CMC 4,7 % 4 MHz 至 5 MHz 20 Ω 至 30 Ω CMC 5,4 % 5 MHz 至 6 MHz 20 Ω 至 30 Ω CMC 8,0 % 6 MHz 至 7 MHz 20 Ω 至 30 Ω CMC 9,3 % 1 MHz 至 2 MHz 30 Ω 至 50 Ω CMC 2,9 % 2 MHz 至 3 MHz 30 Ω 至 50 Ω CMC 3,5 % 3 MHz 至 4 MHz 30 Ω 至 50 Ω CMC 4,0 % 4 MHz 至 5 MHz 30 Ω 至 50 Ω CMC 4,6 % 5 MHz 至 6 MHz 30 Ω 至 50 Ω CMC 6,9 % 6 MHz 至 7 MHz 30 Ω 至 50 Ω CMC 8,0 % 7 MHz 至 8 MHz 30 Ω 至 50 Ω CMC 9,1 % 1 MHz 至 2 MHz 50 Ω 至 100 Ω CMC 2,5 % 2 MHz 至 3 MHz 50 Ω 至 100 Ω CMC 3,0 % 3 MHz 至 4 MHz 50 Ω 至 100 Ω CMC 3,5 % 4 MHz 至 5 MHz 50 Ω 至 100 Ω CMC 4,0 % 5 MHz 至 6 MHz 50 Ω 至 100 Ω CMC 5,9 % 6 MHz 至 7 MHz 50 Ω 至 100 Ω CMC 6,9 % 7 MHz 至 8 MHz 50 Ω 至 100 Ω CMC 7,9 % 1 MHz 至 2 MHz 100 Ω 至 300 Ω CMC 2,8 % 2 MHz 至 3 MHz 100 Ω 至 300 Ω CMC 3,3 % 3 MHz 至 4 MHz 100 Ω 至 300 Ω CMC 3,9 % 4 MHz 至 5 MHz 100 Ω 至 300 Ω CMC 4,4 % 5 MHz 至 6 MHz 100 Ω 至 300 Ω CMC 6,8 % 6 MHz 至 7 MHz 100 Ω 至 300 Ω CMC 7,7 % 7 MHz 至 8 MHz 100 Ω 至 300 Ω CMC 8,8 % 1 MHz 至 2 MHz 300 Ω 至 500 Ω CMC 3,4 % 2 MHz 至 3 MHz 300 Ω 至 500 Ω CMC 4,0 % 3 MHz 至 4 MHz 300 Ω 至 500 Ω CMC 4,7 % 4 MHz 至 5 MHz 300 Ω 至 500 Ω CMC 5,4 % 5 MHz 至 6 MHz 300 Ω 至 500 Ω CMC 8,0 % 6 MHz 至 7 MHz 300 Ω 至 500 Ω CMC 9,3 % 1 MHz 至 2 MHz 500 Ω 至 700 Ω CMC 3,9 % 2 MHz 至 3 MHz 500 Ω 至 700 Ω CMC 4,6 % 3 MHz 至 4 MHz 500 Ω 至 700 Ω CMC 5,5 % 4 MHz 至 5 MHz 500 Ω 至 700 Ω CMC 6,3 % 5 MHz 至 6 MHz 500 Ω 至 700 Ω CMC 9,4 % 1 MHz 至 2 MHz 700 Ω 至 1 kΩ CMC 4,8 % 2 MHz 至 3 MHz 700 Ω 至 1 kΩ CMC 5,7 % 3 MHz 至 4 MHz 700 Ω 至 1 kΩ CMC 6,7 % 4 MHz 至 5 MHz 700 Ω 至 1 kΩ CMC 7,6 % 1 MHz 至 2 MHz 1 kΩ 至 2 kΩ CMC 3,7 % 2 MHz 至 3 MHz 1 kΩ 至 2 kΩ CMC 4,4 % 3 MHz 至 4 MHz 1 kΩ 至 2 kΩ CMC 5,1 % 4 MHz 至 5 MHz 1 kΩ 至 2 kΩ CMC 5,8 % 5 MHz 至 6 MHz 1 kΩ 至 2 kΩ CMC 8,7 % 1 MHz 至 2 MHz 2 kΩ 至 3 kΩ CMC 4,4 % 2 MHz 至 3 MHz 2 kΩ 至 3 kΩ CMC 5,2 % 3 MHz 至 4 MHz 2 kΩ 至 3 kΩ CMC 6,1 % 4 MHz 至 5 MHz 2 kΩ 至 3 kΩ CMC 7,0 % 1 MHz 至 2 MHz 3 kΩ 至 4 kΩ CMC 5,1 % 2 MHz 至 3 MHz 3 kΩ 至 4 kΩ CMC 6,1 % 3 MHz 至 4 MHz 3 kΩ 至 4 kΩ CMC 7,1 % 4 MHz 至 5 MHz 3 kΩ 至 4 kΩ CMC 8,1 % 1 MHz 至 2 MHz 4 kΩ 至 5 kΩ CMC 5,8 % 2 MHz 至 3 MHz 4 kΩ 至 5 kΩ CMC 7,0 % 3 MHz 至 4 MHz 4 kΩ 至 5 kΩ CMC 8,1 % 4 MHz 至 5 MHz 4 kΩ 至 5 kΩ CMC 9,3 % 1 MHz 至 2 MHz 5 kΩ 至 7 kΩ CMC 7,3 % 2 MHz 至 3 MHz 5 kΩ 至 7 kΩ CMC 8,7 % 1 MHz 至 2 MHz 7 kΩ 至 9 kΩ CMC 8,7 % 1 MHz 至 2 MHz 9 kΩ 至 10 kΩ CMC 9,4 % TP6, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"718674d25f7eead0efc4d43b","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"6","test_object":"Rezystancja przy prądzie przemiennym / Mierniki rezystancji przy prądzie przemiennym","test_object_en":"AC resistance / AC resistance meters","test_object_zh":"交流电阻 / 交流电阻测量仪器","test_object_cs":"Střídavý odpor / Měřidla střídavého odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 10 kHz","range":"0,1 Ω","cmc":"0,14 %"},{"name":"10 kHz do 100 kHz","range":"0,1 Ω","cmc":"0,18 %"},{"name":"100 kHz do 300 kHz","range":"0,1 Ω","cmc":"0,34 %"},{"name":"300 kHz do 500 kHz","range":"0,1 Ω","cmc":"0,47 %"},{"name":"500 kHz do 1 MHz","range":"0,1 Ω","cmc":"0,54 %"},{"name":"10 Hz do 10 kHz","range":"1 Ω","cmc":"0,038 %"},{"name":"10 kHz do 100 kHz","range":"1 Ω","cmc":"0,065 %"},{"name":"100 kHz do 300 kHz","range":"1 Ω","cmc":"0,074 %"},{"name":"300 kHz do 500 kHz","range":"1 Ω","cmc":"0,076 %"},{"name":"500 kHz do 1 MHz","range":"1 Ω","cmc":"0,098 %"},{"name":"1 MHz do 5 MHz","range":"1 Ω","cmc":"0,24 %"},{"name":"5 MHz do 10 MHz","range":"1 Ω","cmc":"0,47 %"},{"name":"10 Hz do 10 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"10 kHz do 100 kHz","range":"10 Ω","cmc":"0,055 %"},{"name":"100 kHz do 300 kHz","range":"10 Ω","cmc":"0,050 %"},{"name":"300 kHz do 500 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"500 kHz do 1 MHz","range":"10 Ω","cmc":"0,063 %"},{"name":"1 MHz do 5 MHz","range":"10 Ω","cmc":"0,21 %"},{"name":"5 MHz do 10 MHz","range":"10 Ω","cmc":"0,38 %"},{"name":"10 Hz do 10 kHz","range":"100 Ω","cmc":"0,005 %"},{"name":"10 kHz do 300 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"300 kHz do 1 MHz","range":"100 Ω","cmc":"0,022 %"},{"name":"1 MHz do 5 MHz","range":"100 Ω","cmc":"0,20 %"},{"name":"5 MHz do 10 MHz","range":"100 Ω","cmc":"0,21 %"},{"name":"10 Hz do 10 kHz","range":"1 kΩ","cmc":"0,005 %"},{"name":"10 kHz do 1 MHz","range":"1 kΩ","cmc":"0,025 %"},{"name":"1 MHz do 5 MHz","range":"1 kΩ","cmc":"0,21 %"},{"name":"5 MHz do 10 MHz","range":"1 kΩ","cmc":"0,22 %"},{"name":"10 Hz do 1 MHz","range":"10 kΩ","cmc":"0,025 %"},{"name":"10 Hz do 10 kHz","range":"100 kΩ","cmc":"0,010 %"},{"name":"10 kHz do 500 kHz","range":"100 kΩ","cmc":"0,11 %"},{"name":"500 kHz do 1 MHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"10 Hz do 1 kHz","range":"1 MΩ","cmc":"0,010 %"},{"name":"1 kHz do 1 MHz","range":"1 MΩ","cmc":"0,11 %"},{"name":"10 Hz do 10 kHz","range":"10 MΩ","cmc":"0,016 %"},{"name":"10 kHz do 100 kHz","range":"10 MΩ","cmc":"0,38 %"},{"name":"100 kHz do 300 kHz","range":"10 MΩ","cmc":"0,52 %"},{"name":"300 kHz do 1 MHz","range":"10 MΩ","cmc":"0,58 %"}],"parameters_en":[{"name":"10 Hz to 10 kHz","range":"0,1 Ω","cmc":"0,14 %"},{"name":"10 kHz to 100 kHz","range":"0,1 Ω","cmc":"0,18 %"},{"name":"100 kHz to 300 kHz","range":"0,1 Ω","cmc":"0,34 %"},{"name":"300 kHz to 500 kHz","range":"0,1 Ω","cmc":"0,47 %"},{"name":"500 kHz to 1 MHz","range":"0,1 Ω","cmc":"0,54 %"},{"name":"10 Hz to 10 kHz","range":"1 Ω","cmc":"0,038 %"},{"name":"10 kHz to 100 kHz","range":"1 Ω","cmc":"0,065 %"},{"name":"100 kHz to 300 kHz","range":"1 Ω","cmc":"0,074 %"},{"name":"300 kHz to 500 kHz","range":"1 Ω","cmc":"0,076 %"},{"name":"500 kHz to 1 MHz","range":"1 Ω","cmc":"0,098 %"},{"name":"1 MHz to 5 MHz","range":"1 Ω","cmc":"0,24 %"},{"name":"5 MHz to 10 MHz","range":"1 Ω","cmc":"0,47 %"},{"name":"10 Hz to 10 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"10 kHz to 100 kHz","range":"10 Ω","cmc":"0,055 %"},{"name":"100 kHz to 300 kHz","range":"10 Ω","cmc":"0,050 %"},{"name":"300 kHz to 500 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"500 kHz to 1 MHz","range":"10 Ω","cmc":"0,063 %"},{"name":"1 MHz to 5 MHz","range":"10 Ω","cmc":"0,21 %"},{"name":"5 MHz to 10 MHz","range":"10 Ω","cmc":"0,38 %"},{"name":"10 Hz to 10 kHz","range":"100 Ω","cmc":"0,005 %"},{"name":"10 kHz to 300 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"300 kHz to 1 MHz","range":"100 Ω","cmc":"0,022 %"},{"name":"1 MHz to 5 MHz","range":"100 Ω","cmc":"0,20 %"},{"name":"5 MHz to 10 MHz","range":"100 Ω","cmc":"0,21 %"},{"name":"10 Hz to 10 kHz","range":"1 kΩ","cmc":"0,005 %"},{"name":"10 kHz to 1 MHz","range":"1 kΩ","cmc":"0,025 %"},{"name":"1 MHz to 5 MHz","range":"1 kΩ","cmc":"0,21 %"},{"name":"5 MHz to 10 MHz","range":"1 kΩ","cmc":"0,22 %"},{"name":"10 Hz to 1 MHz","range":"10 kΩ","cmc":"0,025 %"},{"name":"10 Hz to 10 kHz","range":"100 kΩ","cmc":"0,010 %"},{"name":"10 kHz to 500 kHz","range":"100 kΩ","cmc":"0,11 %"},{"name":"500 kHz to 1 MHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"10 Hz to 1 kHz","range":"1 MΩ","cmc":"0,010 %"},{"name":"1 kHz to 1 MHz","range":"1 MΩ","cmc":"0,11 %"},{"name":"10 Hz to 10 kHz","range":"10 MΩ","cmc":"0,016 %"},{"name":"10 kHz to 100 kHz","range":"10 MΩ","cmc":"0,38 %"},{"name":"100 kHz to 300 kHz","range":"10 MΩ","cmc":"0,52 %"},{"name":"300 kHz to 1 MHz","range":"10 MΩ","cmc":"0,58 %"}],"parameters_zh":[{"name":"10 Hz 至 10 kHz","range":"0,1 Ω","cmc":"0,14 %"},{"name":"10 kHz 至 100 kHz","range":"0,1 Ω","cmc":"0,18 %"},{"name":"100 kHz 至 300 kHz","range":"0,1 Ω","cmc":"0,34 %"},{"name":"300 kHz 至 500 kHz","range":"0,1 Ω","cmc":"0,47 %"},{"name":"500 kHz 至 1 MHz","range":"0,1 Ω","cmc":"0,54 %"},{"name":"10 Hz 至 10 kHz","range":"1 Ω","cmc":"0,038 %"},{"name":"10 kHz 至 100 kHz","range":"1 Ω","cmc":"0,065 %"},{"name":"100 kHz 至 300 kHz","range":"1 Ω","cmc":"0,074 %"},{"name":"300 kHz 至 500 kHz","range":"1 Ω","cmc":"0,076 %"},{"name":"500 kHz 至 1 MHz","range":"1 Ω","cmc":"0,098 %"},{"name":"1 MHz 至 5 MHz","range":"1 Ω","cmc":"0,24 %"},{"name":"5 MHz 至 10 MHz","range":"1 Ω","cmc":"0,47 %"},{"name":"10 Hz 至 10 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"10 kHz 至 100 kHz","range":"10 Ω","cmc":"0,055 %"},{"name":"100 kHz 至 300 kHz","range":"10 Ω","cmc":"0,050 %"},{"name":"300 kHz 至 500 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"500 kHz 至 1 MHz","range":"10 Ω","cmc":"0,063 %"},{"name":"1 MHz 至 5 MHz","range":"10 Ω","cmc":"0,21 %"},{"name":"5 MHz 至 10 MHz","range":"10 Ω","cmc":"0,38 %"},{"name":"10 Hz 至 10 kHz","range":"100 Ω","cmc":"0,005 %"},{"name":"10 kHz 至 300 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"300 kHz 至 1 MHz","range":"100 Ω","cmc":"0,022 %"},{"name":"1 MHz 至 5 MHz","range":"100 Ω","cmc":"0,20 %"},{"name":"5 MHz 至 10 MHz","range":"100 Ω","cmc":"0,21 %"},{"name":"10 Hz 至 10 kHz","range":"1 kΩ","cmc":"0,005 %"},{"name":"10 kHz 至 1 MHz","range":"1 kΩ","cmc":"0,025 %"},{"name":"1 MHz 至 5 MHz","range":"1 kΩ","cmc":"0,21 %"},{"name":"5 MHz 至 10 MHz","range":"1 kΩ","cmc":"0,22 %"},{"name":"10 Hz 至 1 MHz","range":"10 kΩ","cmc":"0,025 %"},{"name":"10 Hz 至 10 kHz","range":"100 kΩ","cmc":"0,010 %"},{"name":"10 kHz 至 500 kHz","range":"100 kΩ","cmc":"0,11 %"},{"name":"500 kHz 至 1 MHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"10 Hz 至 1 kHz","range":"1 MΩ","cmc":"0,010 %"},{"name":"1 kHz 至 1 MHz","range":"1 MΩ","cmc":"0,11 %"},{"name":"10 Hz 至 10 kHz","range":"10 MΩ","cmc":"0,016 %"},{"name":"10 kHz 至 100 kHz","range":"10 MΩ","cmc":"0,38 %"},{"name":"100 kHz 至 300 kHz","range":"10 MΩ","cmc":"0,52 %"},{"name":"300 kHz 至 1 MHz","range":"10 MΩ","cmc":"0,58 %"}],"parameters_cs":[{"name":"10 Hz až 10 kHz","range":"0,1 Ω","cmc":"0,14 %"},{"name":"10 kHz až 100 kHz","range":"0,1 Ω","cmc":"0,18 %"},{"name":"100 kHz až 300 kHz","range":"0,1 Ω","cmc":"0,34 %"},{"name":"300 kHz až 500 kHz","range":"0,1 Ω","cmc":"0,47 %"},{"name":"500 kHz až 1 MHz","range":"0,1 Ω","cmc":"0,54 %"},{"name":"10 Hz až 10 kHz","range":"1 Ω","cmc":"0,038 %"},{"name":"10 kHz až 100 kHz","range":"1 Ω","cmc":"0,065 %"},{"name":"100 kHz až 300 kHz","range":"1 Ω","cmc":"0,074 %"},{"name":"300 kHz až 500 kHz","range":"1 Ω","cmc":"0,076 %"},{"name":"500 kHz až 1 MHz","range":"1 Ω","cmc":"0,098 %"},{"name":"1 MHz až 5 MHz","range":"1 Ω","cmc":"0,24 %"},{"name":"5 MHz až 10 MHz","range":"1 Ω","cmc":"0,47 %"},{"name":"10 Hz až 10 kHz","range":"10 Ω","cmc":"0,043 %"},{"name":"10 kHz až 100 kHz","range":"10 Ω","cmc":"0,055 %"},{"name":"100 kHz až 300 kHz","range":"10 Ω","cmc":"0,050 %"},{"name":"300 kHz až 500 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"500 kHz až 1 MHz","range":"10 Ω","cmc":"0,063 %"},{"name":"1 MHz až 5 MHz","range":"10 Ω","cmc":"0,21 %"},{"name":"5 MHz až 10 MHz","range":"10 Ω","cmc":"0,38 %"},{"name":"10 Hz až 10 kHz","range":"100 Ω","cmc":"0,005 %"},{"name":"10 kHz až 300 kHz","range":"100 Ω","cmc":"0,021 %"},{"name":"300 kHz až 1 MHz","range":"100 Ω","cmc":"0,022 %"},{"name":"1 MHz až 5 MHz","range":"100 Ω","cmc":"0,20 %"},{"name":"5 MHz až 10 MHz","range":"100 Ω","cmc":"0,21 %"},{"name":"10 Hz až 10 kHz","range":"1 kΩ","cmc":"0,005 %"},{"name":"10 kHz až 1 MHz","range":"1 kΩ","cmc":"0,025 %"},{"name":"1 MHz až 5 MHz","range":"1 kΩ","cmc":"0,21 %"},{"name":"5 MHz až 10 MHz","range":"1 kΩ","cmc":"0,22 %"},{"name":"10 Hz až 1 MHz","range":"10 kΩ","cmc":"0,025 %"},{"name":"10 Hz až 10 kHz","range":"100 kΩ","cmc":"0,010 %"},{"name":"10 kHz až 500 kHz","range":"100 kΩ","cmc":"0,11 %"},{"name":"500 kHz až 1 MHz","range":"100 kΩ","cmc":"0,12 %"},{"name":"10 Hz až 1 kHz","range":"1 MΩ","cmc":"0,010 %"},{"name":"1 kHz až 1 MHz","range":"1 MΩ","cmc":"0,11 %"},{"name":"10 Hz až 10 kHz","range":"10 MΩ","cmc":"0,016 %"},{"name":"10 kHz až 100 kHz","range":"10 MΩ","cmc":"0,38 %"},{"name":"100 kHz až 300 kHz","range":"10 MΩ","cmc":"0,52 %"},{"name":"300 kHz až 1 MHz","range":"10 MΩ","cmc":"0,58 %"}],"technique":"Pomiar bezpośredni wzorca rezystancji, składowa rzeczywista impedancji","technique_en":"Direct measurement of a resistance standard, real impedance","technique_zh":"直接测量电阻标准器，阻抗实部","technique_cs":"Přímé měření etalonu odporu, reálná složka impedance","techniques":["Pomiar bezpośredni wzorca rezystancji, składowa rzeczywista impedancji"],"techniques_en":["Direct measurement of a resistance standard, real impedance"],"techniques_zh":["直接测量电阻标准器，阻抗实部"],"techniques_cs":["Přímé měření etalonu odporu, reálná složka impedance"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 10 kHz 0,1 Ω CMC 0,14 %\n10 kHz do 100 kHz 0,1 Ω CMC 0,18 %\n100 kHz do 300 kHz 0,1 Ω CMC 0,34 %\n300 kHz do 500 kHz 0,1 Ω CMC 0,47 %\n500 kHz do 1 MHz 0,1 Ω CMC 0,54 %\n10 Hz do 10 kHz 1 Ω CMC 0,038 %\n10 kHz do 100 kHz 1 Ω CMC 0,065 %\n100 kHz do 300 kHz 1 Ω CMC 0,074 %\n300 kHz do 500 kHz 1 Ω CMC 0,076 %\n500 kHz do 1 MHz 1 Ω CMC 0,098 %\n1 MHz do 5 MHz 1 Ω CMC 0,24 %\n5 MHz do 10 MHz 1 Ω CMC 0,47 %\n10 Hz do 10 kHz 10 Ω CMC 0,043 %\n10 kHz do 100 kHz 10 Ω CMC 0,055 %\n100 kHz do 300 kHz 10 Ω CMC 0,050 %\n300 kHz do 500 kHz 10 Ω CMC 0,045 %\n500 kHz do 1 MHz 10 Ω CMC 0,063 %\n1 MHz do 5 MHz 10 Ω CMC 0,21 %\n5 MHz do 10 MHz 10 Ω CMC 0,38 %\n10 Hz do 10 kHz 100 Ω CMC 0,005 %\n10 kHz do 300 kHz 100 Ω CMC 0,021 %\n300 kHz do 1 MHz 100 Ω CMC 0,022 %\n1 MHz do 5 MHz 100 Ω CMC 0,20 %\n5 MHz do 10 MHz 100 Ω CMC 0,21 %\n10 Hz do 10 kHz 1 kΩ CMC 0,005 %\n10 kHz do 1 MHz 1 kΩ CMC 0,025 %\n1 MHz do 5 MHz 1 kΩ CMC 0,21 %\n5 MHz do 10 MHz 1 kΩ CMC 0,22 %\n10 Hz do 1 MHz 10 kΩ CMC 0,025 %\n10 Hz do 10 kHz 100 kΩ CMC 0,010 %\n10 kHz do 500 kHz 100 kΩ CMC 0,11 %\n500 kHz do 1 MHz 100 kΩ CMC 0,12 %\n10 Hz do 1 kHz 1 MΩ CMC 0,010 %\n1 kHz do 1 MHz 1 MΩ CMC 0,11 %\n10 Hz do 10 kHz 10 MΩ CMC 0,016 %\n10 kHz do 100 kHz 10 MΩ CMC 0,38 %\n100 kHz do 300 kHz 10 MΩ CMC 0,52 %\n300 kHz do 1 MHz 10 MΩ CMC 0,58 %\nPomiar bezpośredni wzorca rezystancji, składowa rzeczywista impedancji","reference":"TP6, TP24","norm_bases":["TP6","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie przemiennym / Mierniki rezystancji przy prądzie przemiennym Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorca rezystancji, składowa rzeczywista impedancji 10 Hz do 10 kHz 0,1 Ω CMC 0,14 % 10 kHz do 100 kHz 0,1 Ω CMC 0,18 % 100 kHz do 300 kHz 0,1 Ω CMC 0,34 % 300 kHz do 500 kHz 0,1 Ω CMC 0,47 % 500 kHz do 1 MHz 0,1 Ω CMC 0,54 % 10 Hz do 10 kHz 1 Ω CMC 0,038 % 10 kHz do 100 kHz 1 Ω CMC 0,065 % 100 kHz do 300 kHz 1 Ω CMC 0,074 % 300 kHz do 500 kHz 1 Ω CMC 0,076 % 500 kHz do 1 MHz 1 Ω CMC 0,098 % 1 MHz do 5 MHz 1 Ω CMC 0,24 % 5 MHz do 10 MHz 1 Ω CMC 0,47 % 10 Hz do 10 kHz 10 Ω CMC 0,043 % 10 kHz do 100 kHz 10 Ω CMC 0,055 % 100 kHz do 300 kHz 10 Ω CMC 0,050 % 300 kHz do 500 kHz 10 Ω CMC 0,045 % 500 kHz do 1 MHz 10 Ω CMC 0,063 % 1 MHz do 5 MHz 10 Ω CMC 0,21 % 5 MHz do 10 MHz 10 Ω CMC 0,38 % 10 Hz do 10 kHz 100 Ω CMC 0,005 % 10 kHz do 300 kHz 100 Ω CMC 0,021 % 300 kHz do 1 MHz 100 Ω CMC 0,022 % 1 MHz do 5 MHz 100 Ω CMC 0,20 % 5 MHz do 10 MHz 100 Ω CMC 0,21 % 10 Hz do 10 kHz 1 kΩ CMC 0,005 % 10 kHz do 1 MHz 1 kΩ CMC 0,025 % 1 MHz do 5 MHz 1 kΩ CMC 0,21 % 5 MHz do 10 MHz 1 kΩ CMC 0,22 % 10 Hz do 1 MHz 10 kΩ CMC 0,025 % 10 Hz do 10 kHz 100 kΩ CMC 0,010 % 10 kHz do 500 kHz 100 kΩ CMC 0,11 % 500 kHz do 1 MHz 100 kΩ CMC 0,12 % 10 Hz do 1 kHz 1 MΩ CMC 0,010 % 1 kHz do 1 MHz 1 MΩ CMC 0,11 % 10 Hz do 10 kHz 10 MΩ CMC 0,016 % 10 kHz do 100 kHz 10 MΩ CMC 0,38 % 100 kHz do 300 kHz 10 MΩ CMC 0,52 % 300 kHz do 1 MHz 10 MΩ CMC 0,58 % Střídavý odpor / Měřidla střídavého odporu Kalibrace – elektrické veličiny Přímé měření etalonu odporu, reálná složka impedance 10 Hz až 10 kHz 0,1 Ω CMC 0,14 % 10 kHz až 100 kHz 0,1 Ω CMC 0,18 % 100 kHz až 300 kHz 0,1 Ω CMC 0,34 % 300 kHz až 500 kHz 0,1 Ω CMC 0,47 % 500 kHz až 1 MHz 0,1 Ω CMC 0,54 % 10 Hz až 10 kHz 1 Ω CMC 0,038 % 10 kHz až 100 kHz 1 Ω CMC 0,065 % 100 kHz až 300 kHz 1 Ω CMC 0,074 % 300 kHz až 500 kHz 1 Ω CMC 0,076 % 500 kHz až 1 MHz 1 Ω CMC 0,098 % 1 MHz až 5 MHz 1 Ω CMC 0,24 % 5 MHz až 10 MHz 1 Ω CMC 0,47 % 10 Hz až 10 kHz 10 Ω CMC 0,043 % 10 kHz až 100 kHz 10 Ω CMC 0,055 % 100 kHz až 300 kHz 10 Ω CMC 0,050 % 300 kHz až 500 kHz 10 Ω CMC 0,045 % 500 kHz až 1 MHz 10 Ω CMC 0,063 % 1 MHz až 5 MHz 10 Ω CMC 0,21 % 5 MHz až 10 MHz 10 Ω CMC 0,38 % 10 Hz až 10 kHz 100 Ω CMC 0,005 % 10 kHz až 300 kHz 100 Ω CMC 0,021 % 300 kHz až 1 MHz 100 Ω CMC 0,022 % 1 MHz až 5 MHz 100 Ω CMC 0,20 % 5 MHz až 10 MHz 100 Ω CMC 0,21 % 10 Hz až 10 kHz 1 kΩ CMC 0,005 % 10 kHz až 1 MHz 1 kΩ CMC 0,025 % 1 MHz až 5 MHz 1 kΩ CMC 0,21 % 5 MHz až 10 MHz 1 kΩ CMC 0,22 % 10 Hz až 1 MHz 10 kΩ CMC 0,025 % 10 Hz až 10 kHz 100 kΩ CMC 0,010 % 10 kHz až 500 kHz 100 kΩ CMC 0,11 % 500 kHz až 1 MHz 100 kΩ CMC 0,12 % 10 Hz až 1 kHz 1 MΩ CMC 0,010 % 1 kHz až 1 MHz 1 MΩ CMC 0,11 % 10 Hz až 10 kHz 10 MΩ CMC 0,016 % 10 kHz až 100 kHz 10 MΩ CMC 0,38 % 100 kHz až 300 kHz 10 MΩ CMC 0,52 % 300 kHz až 1 MHz 10 MΩ CMC 0,58 % TP6, TP24 Rezystancja przy pradzie przemiennym / Mierniki rezystancji przy pradzie przemiennym Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorca rezystancji, skladowa rzeczywista impedancji 10 Hz do 10 kHz 0,1 Ω CMC 0,14 % 10 kHz do 100 kHz 0,1 Ω CMC 0,18 % 100 kHz do 300 kHz 0,1 Ω CMC 0,34 % 300 kHz do 500 kHz 0,1 Ω CMC 0,47 % 500 kHz do 1 MHz 0,1 Ω CMC 0,54 % 10 Hz do 10 kHz 1 Ω CMC 0,038 % 10 kHz do 100 kHz 1 Ω CMC 0,065 % 100 kHz do 300 kHz 1 Ω CMC 0,074 % 300 kHz do 500 kHz 1 Ω CMC 0,076 % 500 kHz do 1 MHz 1 Ω CMC 0,098 % 1 MHz do 5 MHz 1 Ω CMC 0,24 % 5 MHz do 10 MHz 1 Ω CMC 0,47 % 10 Hz do 10 kHz 10 Ω CMC 0,043 % 10 kHz do 100 kHz 10 Ω CMC 0,055 % 100 kHz do 300 kHz 10 Ω CMC 0,050 % 300 kHz do 500 kHz 10 Ω CMC 0,045 % 500 kHz do 1 MHz 10 Ω CMC 0,063 % 1 MHz do 5 MHz 10 Ω CMC 0,21 % 5 MHz do 10 MHz 10 Ω CMC 0,38 % 10 Hz do 10 kHz 100 Ω CMC 0,005 % 10 kHz do 300 kHz 100 Ω CMC 0,021 % 300 kHz do 1 MHz 100 Ω CMC 0,022 % 1 MHz do 5 MHz 100 Ω CMC 0,20 % 5 MHz do 10 MHz 100 Ω CMC 0,21 % 10 Hz do 10 kHz 1 kΩ CMC 0,005 % 10 kHz do 1 MHz 1 kΩ CMC 0,025 % 1 MHz do 5 MHz 1 kΩ CMC 0,21 % 5 MHz do 10 MHz 1 kΩ CMC 0,22 % 10 Hz do 1 MHz 10 kΩ CMC 0,025 % 10 Hz do 10 kHz 100 kΩ CMC 0,010 % 10 kHz do 500 kHz 100 kΩ CMC 0,11 % 500 kHz do 1 MHz 100 kΩ CMC 0,12 % 10 Hz do 1 kHz 1 MΩ CMC 0,010 % 1 kHz do 1 MHz 1 MΩ CMC 0,11 % 10 Hz do 10 kHz 10 MΩ CMC 0,016 % 10 kHz do 100 kHz 10 MΩ CMC 0,38 % 100 kHz do 300 kHz 10 MΩ CMC 0,52 % 300 kHz do 1 MHz 10 MΩ CMC 0,58 % Stridavy odpor / Meridla stridaveho odporu Kalibrace – elektricke veliciny Prime mereni etalonu odporu, realna slozka impedance 10 Hz az 10 kHz 0,1 Ω CMC 0,14 % 10 kHz az 100 kHz 0,1 Ω CMC 0,18 % 100 kHz az 300 kHz 0,1 Ω CMC 0,34 % 300 kHz az 500 kHz 0,1 Ω CMC 0,47 % 500 kHz az 1 MHz 0,1 Ω CMC 0,54 % 10 Hz az 10 kHz 1 Ω CMC 0,038 % 10 kHz az 100 kHz 1 Ω CMC 0,065 % 100 kHz az 300 kHz 1 Ω CMC 0,074 % 300 kHz az 500 kHz 1 Ω CMC 0,076 % 500 kHz az 1 MHz 1 Ω CMC 0,098 % 1 MHz az 5 MHz 1 Ω CMC 0,24 % 5 MHz az 10 MHz 1 Ω CMC 0,47 % 10 Hz az 10 kHz 10 Ω CMC 0,043 % 10 kHz az 100 kHz 10 Ω CMC 0,055 % 100 kHz az 300 kHz 10 Ω CMC 0,050 % 300 kHz az 500 kHz 10 Ω CMC 0,045 % 500 kHz az 1 MHz 10 Ω CMC 0,063 % 1 MHz az 5 MHz 10 Ω CMC 0,21 % 5 MHz az 10 MHz 10 Ω CMC 0,38 % 10 Hz az 10 kHz 100 Ω CMC 0,005 % 10 kHz az 300 kHz 100 Ω CMC 0,021 % 300 kHz az 1 MHz 100 Ω CMC 0,022 % 1 MHz az 5 MHz 100 Ω CMC 0,20 % 5 MHz az 10 MHz 100 Ω CMC 0,21 % 10 Hz az 10 kHz 1 kΩ CMC 0,005 % 10 kHz az 1 MHz 1 kΩ CMC 0,025 % 1 MHz az 5 MHz 1 kΩ CMC 0,21 % 5 MHz az 10 MHz 1 kΩ CMC 0,22 % 10 Hz az 1 MHz 10 kΩ CMC 0,025 % 10 Hz az 10 kHz 100 kΩ CMC 0,010 % 10 kHz az 500 kHz 100 kΩ CMC 0,11 % 500 kHz az 1 MHz 100 kΩ CMC 0,12 % 10 Hz az 1 kHz 1 MΩ CMC 0,010 % 1 kHz az 1 MHz 1 MΩ CMC 0,11 % 10 Hz az 10 kHz 10 MΩ CMC 0,016 % 10 kHz az 100 kHz 10 MΩ CMC 0,38 % 100 kHz az 300 kHz 10 MΩ CMC 0,52 % 300 kHz az 1 MHz 10 MΩ CMC 0,58 % TP6, TP24","search_en":"AC resistance / AC resistance meters Calibration – electrical quantities Direct measurement of a resistance standard, real impedance 10 Hz to 10 kHz 0,1 Ω CMC 0,14 % 10 kHz to 100 kHz 0,1 Ω CMC 0,18 % 100 kHz to 300 kHz 0,1 Ω CMC 0,34 % 300 kHz to 500 kHz 0,1 Ω CMC 0,47 % 500 kHz to 1 MHz 0,1 Ω CMC 0,54 % 10 Hz to 10 kHz 1 Ω CMC 0,038 % 10 kHz to 100 kHz 1 Ω CMC 0,065 % 100 kHz to 300 kHz 1 Ω CMC 0,074 % 300 kHz to 500 kHz 1 Ω CMC 0,076 % 500 kHz to 1 MHz 1 Ω CMC 0,098 % 1 MHz to 5 MHz 1 Ω CMC 0,24 % 5 MHz to 10 MHz 1 Ω CMC 0,47 % 10 Hz to 10 kHz 10 Ω CMC 0,043 % 10 kHz to 100 kHz 10 Ω CMC 0,055 % 100 kHz to 300 kHz 10 Ω CMC 0,050 % 300 kHz to 500 kHz 10 Ω CMC 0,045 % 500 kHz to 1 MHz 10 Ω CMC 0,063 % 1 MHz to 5 MHz 10 Ω CMC 0,21 % 5 MHz to 10 MHz 10 Ω CMC 0,38 % 10 Hz to 10 kHz 100 Ω CMC 0,005 % 10 kHz to 300 kHz 100 Ω CMC 0,021 % 300 kHz to 1 MHz 100 Ω CMC 0,022 % 1 MHz to 5 MHz 100 Ω CMC 0,20 % 5 MHz to 10 MHz 100 Ω CMC 0,21 % 10 Hz to 10 kHz 1 kΩ CMC 0,005 % 10 kHz to 1 MHz 1 kΩ CMC 0,025 % 1 MHz to 5 MHz 1 kΩ CMC 0,21 % 5 MHz to 10 MHz 1 kΩ CMC 0,22 % 10 Hz to 1 MHz 10 kΩ CMC 0,025 % 10 Hz to 10 kHz 100 kΩ CMC 0,010 % 10 kHz to 500 kHz 100 kΩ CMC 0,11 % 500 kHz to 1 MHz 100 kΩ CMC 0,12 % 10 Hz to 1 kHz 1 MΩ CMC 0,010 % 1 kHz to 1 MHz 1 MΩ CMC 0,11 % 10 Hz to 10 kHz 10 MΩ CMC 0,016 % 10 kHz to 100 kHz 10 MΩ CMC 0,38 % 100 kHz to 300 kHz 10 MΩ CMC 0,52 % 300 kHz to 1 MHz 10 MΩ CMC 0,58 % TP6, TP24","search_zh":"交流电阻 / 交流电阻测量仪器 校准 – 电学量 直接测量电阻标准器，阻抗实部 10 Hz 至 10 kHz 0,1 Ω CMC 0,14 % 10 kHz 至 100 kHz 0,1 Ω CMC 0,18 % 100 kHz 至 300 kHz 0,1 Ω CMC 0,34 % 300 kHz 至 500 kHz 0,1 Ω CMC 0,47 % 500 kHz 至 1 MHz 0,1 Ω CMC 0,54 % 10 Hz 至 10 kHz 1 Ω CMC 0,038 % 10 kHz 至 100 kHz 1 Ω CMC 0,065 % 100 kHz 至 300 kHz 1 Ω CMC 0,074 % 300 kHz 至 500 kHz 1 Ω CMC 0,076 % 500 kHz 至 1 MHz 1 Ω CMC 0,098 % 1 MHz 至 5 MHz 1 Ω CMC 0,24 % 5 MHz 至 10 MHz 1 Ω CMC 0,47 % 10 Hz 至 10 kHz 10 Ω CMC 0,043 % 10 kHz 至 100 kHz 10 Ω CMC 0,055 % 100 kHz 至 300 kHz 10 Ω CMC 0,050 % 300 kHz 至 500 kHz 10 Ω CMC 0,045 % 500 kHz 至 1 MHz 10 Ω CMC 0,063 % 1 MHz 至 5 MHz 10 Ω CMC 0,21 % 5 MHz 至 10 MHz 10 Ω CMC 0,38 % 10 Hz 至 10 kHz 100 Ω CMC 0,005 % 10 kHz 至 300 kHz 100 Ω CMC 0,021 % 300 kHz 至 1 MHz 100 Ω CMC 0,022 % 1 MHz 至 5 MHz 100 Ω CMC 0,20 % 5 MHz 至 10 MHz 100 Ω CMC 0,21 % 10 Hz 至 10 kHz 1 kΩ CMC 0,005 % 10 kHz 至 1 MHz 1 kΩ CMC 0,025 % 1 MHz 至 5 MHz 1 kΩ CMC 0,21 % 5 MHz 至 10 MHz 1 kΩ CMC 0,22 % 10 Hz 至 1 MHz 10 kΩ CMC 0,025 % 10 Hz 至 10 kHz 100 kΩ CMC 0,010 % 10 kHz 至 500 kHz 100 kΩ CMC 0,11 % 500 kHz 至 1 MHz 100 kΩ CMC 0,12 % 10 Hz 至 1 kHz 1 MΩ CMC 0,010 % 1 kHz 至 1 MHz 1 MΩ CMC 0,11 % 10 Hz 至 10 kHz 10 MΩ CMC 0,016 % 10 kHz 至 100 kHz 10 MΩ CMC 0,38 % 100 kHz 至 300 kHz 10 MΩ CMC 0,52 % 300 kHz 至 1 MHz 10 MΩ CMC 0,58 % TP6, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15ab0a8abff3bfbfe1254b4c","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"7","test_object":"Pojemność / Wzorce pojemności","test_object_en":"Capacity / Capacity standards","test_object_zh":"电容 / 电容标准器","test_object_cs":"Kapacita / Etalony kapacity","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 kHz do 15 kHz","range":"od 1 pF do 5 pF","cmc":"2,2 %"},{"name":"15 kHz do 20 kHz","range":"od 1 pF do 5 pF","cmc":"1,5 %"},{"name":"20 kHz do 25 kHz","range":"od 1 pF do 5 pF","cmc":"1,2 %"},{"name":"25 kHz do 30 kHz","range":"od 1 pF do 5 pF","cmc":"0,94 %"},{"name":"30 kHz do 40 kHz","range":"od 1 pF do 5 pF","cmc":"0,81 %"},{"name":"40 kHz do 50 kHz","range":"od 1 pF do 5 pF","cmc":"0,65 %"},{"name":"50 kHz do 60 kHz","range":"od 1 pF do 5 pF","cmc":"0,55 %"},{"name":"60 kHz do 70 kHz","range":"od 1 pF do 5 pF","cmc":"0,49 %"},{"name":"70 kHz do 80 kHz","range":"od 1 pF do 5 pF","cmc":"0,44 %"},{"name":"80 kHz do 100 kHz","range":"od 1 pF do 5 pF","cmc":"0,40 %"},{"name":"100 kHz do 110 kHz","range":"od 1 pF do 5 pF","cmc":"0,75 %"},{"name":"110 kHz do 120 kHz","range":"od 1 pF do 5 pF","cmc":"0,69 %"},{"name":"120 kHz do 130 kHz","range":"od 1 pF do 5 pF","cmc":"0,65 %"},{"name":"130 kHz do 140 kHz","range":"od 1 pF do 5 pF","cmc":"0,61 %"},{"name":"140 kHz do 150 kHz","range":"od 1 pF do 5 pF","cmc":"0,58 %"},{"name":"150 kHz do 170 kHz","range":"od 1 pF do 5 pF","cmc":"0,55 %"},{"name":"170 kHz do 200 kHz","range":"od 1 pF do 5 pF","cmc":"0,50 %"},{"name":"200 kHz do 250 kHz","range":"od 1 pF do 5 pF","cmc":"0,45 %"},{"name":"250 kHz do 300 kHz","range":"od 1 pF do 5 pF","cmc":"0,39 %"},{"name":"300 kHz do 350 kHz","range":"od 1 pF do 5 pF","cmc":"0,81 %"},{"name":"350 kHz do 400 kHz","range":"od 1 pF do 5 pF","cmc":"0,72 %"},{"name":"400 kHz do 450 kHz","range":"od 1 pF do 5 pF","cmc":"0,65 %"},{"name":"450 kHz do 500 kHz","range":"od 1 pF do 5 pF","cmc":"0,59 %"},{"name":"500 kHz do 600 kHz","range":"od 1 pF do 5 pF","cmc":"0,55 %"},{"name":"600 kHz do 700 kHz","range":"od 1 pF do 5 pF","cmc":"0,49 %"},{"name":"700 kHz do 800 kHz","range":"od 1 pF do 5 pF","cmc":"0,44 %"},{"name":"800 kHz do 1 MHz","range":"od 1 pF do 5 pF","cmc":"0,40 %"},{"name":"1 kHz do 2 kHz","range":"od 5 pF do 10 pF","cmc":"4,1 %"},{"name":"2 kHz do 3 kHz","range":"od 5 pF do 10 pF","cmc":"2,2 %"},{"name":"3 kHz do 4 kHz","range":"od 5 pF do 10 pF","cmc":"1,5 %"},{"name":"4 kHz do 5 kHz","range":"od 5 pF do 10 pF","cmc":"1,2 %"},{"name":"5 kHz do 6 kHz","range":"od 5 pF do 10 pF","cmc":"0,94 %"},{"name":"6 kHz do 7 kHz","range":"od 5 pF do 10 pF","cmc":"0,81 %"},{"name":"7 kHz do 8 kHz","range":"od 5 pF do 10 pF","cmc":"0,72 %"},{"name":"8 kHz do 9 kHz","range":"od 5 pF do 10 pF","cmc":"0,65 %"},{"name":"9 kHz do 10 kHz","range":"od 5 pF do 10 pF","cmc":"0,59 %"},{"name":"10 kHz do 15 kHz","range":"od 5 pF do 10 pF","cmc":"0,55 %"},{"name":"15 kHz do 20 kHz","range":"od 5 pF do 10 pF","cmc":"0,42 %"},{"name":"20 kHz do 25 kHz","range":"od 5 pF do 10 pF","cmc":"0,36 %"},{"name":"25 kHz do 30 kHz","range":"od 5 pF do 10 pF","cmc":"0,32 %"},{"name":"30 kHz do 1 MHz","range":"od 5 pF do 10 pF","cmc":"0,29 %"},{"name":"500 Hz do 600 Hz","range":"od 10 pF do 50 pF","cmc":"4,3 %"},{"name":"600 Hz do 700 Hz","range":"od 10 pF do 50 pF","cmc":"3,7 %"},{"name":"700 Hz do 800 Hz","range":"od 10 pF do 50 pF","cmc":"3,2 %"},{"name":"800 Hz do 900 Hz","range":"od 10 pF do 50 pF","cmc":"2,8 %"},{"name":"900 Hz do 1 kHz","range":"od 10 pF do 50 pF","cmc":"2,6 %"},{"name":"1 kHz do 2 kHz","range":"od 10 pF do 50 pF","cmc":"2,2 %"},{"name":"2 kHz do 3 kHz","range":"od 10 pF do 50 pF","cmc":"1,2 %"},{"name":"3 kHz do 4 kHz","range":"od 10 pF do 50 pF","cmc":"0,81 %"},{"name":"4 kHz do 5 kHz","range":"od 10 pF do 50 pF","cmc":"0,65 %"},{"name":"5 kHz do 6 kHz","range":"od 10 pF do 50 pF","cmc":"0,55 %"},{"name":"6 kHz do 7 kHz","range":"od 10 pF do 50 pF","cmc":"0,49 %"},{"name":"7 kHz do 8 kHz","range":"od 10 pF do 50 pF","cmc":"0,44 %"},{"name":"8 kHz do 9 kHz","range":"od 10 pF do 50 pF","cmc":"0,40 %"},{"name":"9 kHz do 10 kHz","range":"od 10 pF do 50 pF","cmc":"0,38 %"},{"name":"10 kHz do 15 kHz","range":"od 10 pF do 50 pF","cmc":"0,36 %"},{"name":"15 kHz do 20 kHz","range":"od 10 pF do 50 pF","cmc":"0,29 %"},{"name":"20 kHz do 1 MHz","range":"od 10 pF do 50 pF","cmc":"0,26 %"},{"name":"100 Hz do 200 Hz","range":"od 50 pF do 100 pF","cmc":"4,3 %"},{"name":"200 Hz do 300 Hz","range":"od 50 pF do 100 pF","cmc":"2,3 %"},{"name":"300 Hz do 400 Hz","range":"od 50 pF do 100 pF","cmc":"1,7 %"},{"name":"400 Hz do 500 Hz","range":"od 50 pF do 100 pF","cmc":"1,4 %"},{"name":"500 Hz do 600 Hz","range":"od 50 pF do 100 pF","cmc":"1,2 %"},{"name":"600 Hz do 700 Hz","range":"od 50 pF do 100 pF","cmc":"0,99 %"},{"name":"700 Hz do 800 Hz","range":"od 50 pF do 100 pF","cmc":"0,89 %"},{"name":"800 Hz do 900 Hz","range":"od 50 pF do 100 pF","cmc":"0,82 %"},{"name":"900 Hz do 1 kHz","range":"od 50 pF do 100 pF","cmc":"0,77 %"},{"name":"1 kHz do 2 kHz","range":"od 50 pF do 100 pF","cmc":"0,55 %"},{"name":"2 kHz do 3 kHz","range":"od 50 pF do 100 pF","cmc":"0,36 %"},{"name":"3 kHz do 4 kHz","range":"od 50 pF do 100 pF","cmc":"0,29 %"},{"name":"4 kHz do 5 kHz","range":"od 50 pF do 100 pF","cmc":"0,26 %"},{"name":"5 kHz do 1 MHz","range":"od 50 pF do 100 pF","cmc":"0,24 %"},{"name":"50 Hz do 60 Hz","range":"od 100 pF do 500 pF","cmc":"9,9 %"},{"name":"60 Hz do 70 Hz","range":"od 100 pF do 500 pF","cmc":"7,9 %"},{"name":"70 Hz do 80 Hz","range":"od 100 pF do 500 pF","cmc":"6,5 %"},{"name":"80 Hz do 90 Hz","range":"od 100 pF do 500 pF","cmc":"5,6 %"},{"name":"90 Hz do 100 Hz","range":"od 100 pF do 500 pF","cmc":"4,9 %"},{"name":"100 Hz do 160 Hz","range":"od 100 pF do 500 pF","cmc":"2,3 %"},{"name":"160 Hz do 200 Hz","range":"od 100 pF do 500 pF","cmc":"1,4 %"},{"name":"200 Hz do 300 Hz","range":"od 100 pF do 500 pF","cmc":"1,2 %"},{"name":"300 Hz do 400 Hz","range":"od 100 pF do 500 pF","cmc":"0,81 %"},{"name":"400 Hz do 500 Hz","range":"od 100 pF do 500 pF","cmc":"0,65 %"},{"name":"500 Hz do 600 Hz","range":"od 100 pF do 500 pF","cmc":"0,55 %"},{"name":"600 Hz do 700 Hz","range":"od 100 pF do 500 pF","cmc":"0,49 %"},{"name":"700 Hz do 800 Hz","range":"od 100 pF do 500 pF","cmc":"0,44 %"},{"name":"800 Hz do 900 Hz","range":"od 100 pF do 500 pF","cmc":"0,40 %"},{"name":"900 Hz do 1 kHz","range":"od 100 pF do 500 pF","cmc":"0,38 %"},{"name":"1 kHz do 2 kHz","range":"od 100 pF do 500 pF","cmc":"0,36 %"},{"name":"2 kHz do 3 kHz","range":"od 100 pF do 500 pF","cmc":"0,26 %"},{"name":"3 kHz do 4 kHz","range":"od 100 pF do 500 pF","cmc":"0,23 %"},{"name":"4 kHz do 5 kHz","range":"od 100 pF do 500 pF","cmc":"0,21 %"},{"name":"5 kHz do 1 MHz","range":"od 100 pF do 500 pF","cmc":"0,17 %"},{"name":"50 Hz do 60 Hz","range":"od 500 pF do 1 nF","cmc":"2,3 %"},{"name":"60 Hz do 70 Hz","range":"od 500 pF do 1 nF","cmc":"1,9 %"},{"name":"70 Hz do 80 Hz","range":"od 500 pF do 1 nF","cmc":"1,6 %"},{"name":"80 Hz do 100 Hz","range":"od 500 pF do 1 nF","cmc":"1,4 %"},{"name":"100 Hz do 160 Hz","range":"od 500 pF do 1 nF","cmc":"0,72 %"},{"name":"160 Hz do 200 Hz","range":"od 500 pF do 1 nF","cmc":"0,40 %"},{"name":"200 Hz do 300 Hz","range":"od 500 pF do 1 nF","cmc":"0,36 %"},{"name":"300 Hz do 400 Hz","range":"od 500 pF do 1 nF","cmc":"0,29 %"},{"name":"400 Hz do 500 Hz","range":"od 500 pF do 1 nF","cmc":"0,26 %"},{"name":"500 Hz do 700 Hz","range":"od 500 pF do 1 nF","cmc":"0,24 %"},{"name":"700 Hz do 1 kHz","range":"od 500 pF do 1 nF","cmc":"0,22 %"},{"name":"1 kHz do 2 kHz","range":"od 500 pF do 1 nF","cmc":"0,36 %"},{"name":"2 kHz do 3 kHz","range":"od 500 pF do 1 nF","cmc":"0,26 %"},{"name":"3 kHz do 4 kHz","range":"od 500 pF do 1 nF","cmc":"0,23 %"},{"name":"4 kHz do 5 kHz","range":"od 500 pF do 1 nF","cmc":"0,21 %"},{"name":"5 kHz do 1 MHz","range":"od 500 pF do 1 nF","cmc":"0,17 %"},{"name":"20 Hz do 30 Hz","range":"od 1 nF do 5 nF","cmc":"3,6 %"},{"name":"30 Hz do 40 Hz","range":"od 1 nF do 5 nF","cmc":"2,2 %"},{"name":"40 Hz do 50 Hz","range":"od 1 nF do 5 nF","cmc":"1,6 %"},{"name":"50 Hz do 60 Hz","range":"od 1 nF do 5 nF","cmc":"1,2 %"},{"name":"60 Hz do 70 Hz","range":"od 1 nF do 5 nF","cmc":"0,91 %"},{"name":"70 Hz do 80 Hz","range":"od 1 nF do 5 nF","cmc":"0,77 %"},{"name":"80 Hz do 90 Hz","range":"od 1 nF do 5 nF","cmc":"0,68 %"},{"name":"90 Hz do 100 Hz","range":"od 1 nF do 5 nF","cmc":"0,61 %"},{"name":"100 Hz do 200 Hz","range":"od 1 nF do 5 nF","cmc":"0,36 %"},{"name":"200 Hz do 300 Hz","range":"od 1 nF do 5 nF","cmc":"0,26 %"},{"name":"300 Hz do 500 Hz","range":"od 1 nF do 5 nF","cmc":"0,23 %"},{"name":"500 Hz do 1 MHz","range":"od 1 nF do 5 nF","cmc":"0,15 %"},{"name":"20 Hz do 30 Hz","range":"od 5 nF do 10 nF","cmc":"0,97 %"},{"name":"30 Hz do 40 Hz","range":"od 5 nF do 10 nF","cmc":"0,70 %"},{"name":"40 Hz do 50 Hz","range":"od 5 nF do 10 nF","cmc":"0,58 %"},{"name":"50 Hz do 60 Hz","range":"od 5 nF do 10 nF","cmc":"0,35 %"},{"name":"60 Hz do 70 Hz","range":"od 5 nF do 10 nF","cmc":"0,31 %"},{"name":"70 Hz do 100 Hz","range":"od 5 nF do 10 nF","cmc":"0,28 %"},{"name":"100 Hz do 400 Hz","range":"od 5 nF do 10 nF","cmc":"0,20 %"},{"name":"400 Hz do 500 Hz","range":"od 5 nF do 10 nF","cmc":"0,17 %"},{"name":"500 Hz do 1 MHz","range":"od 5 nF do 10 nF","cmc":"0,13 %"},{"name":"20 Hz do 30 Hz","range":"od 10 nF do 50 nF","cmc":"0,65 %"},{"name":"30 Hz do 40 Hz","range":"od 10 nF do 50 nF","cmc":"0,52 %"},{"name":"40 Hz do 50 Hz","range":"od 10 nF do 50 nF","cmc":"0,46 %"},{"name":"50 Hz do 70 Hz","range":"od 10 nF do 50 nF","cmc":"0,26 %"},{"name":"70 Hz do 100 Hz","range":"od 10 nF do 50 nF","cmc":"0,22 %"},{"name":"100 Hz do 103 kHz","range":"od 10 nF do 50 nF","cmc":"0,13 %"},{"name":"103 kHz do 150 kHz","range":"od 10 nF do 50 nF","cmc":"0,19 %"},{"name":"150 kHz do 300 kHz","range":"od 10 nF do 50 nF","cmc":"0,21 %"},{"name":"300 kHz do 500 kHz","range":"od 10 nF do 50 nF","cmc":"0,28 %"},{"name":"500 kHz do 1 MHz","range":"od 10 nF do 50 nF","cmc":"0,39 %"},{"name":"20 Hz do 40 Hz","range":"od 50 nF do 100 nF","cmc":"0,40 %"},{"name":"40 Hz do 50 Hz","range":"od 50 nF do 100 nF","cmc":"0,36 %"},{"name":"50 Hz do 70 Hz","range":"od 50 nF do 100 nF","cmc":"0,26 %"},{"name":"70 Hz do 100 Hz","range":"od 50 nF do 100 nF","cmc":"0,22 %"},{"name":"100 Hz do 103 kHz","range":"od 50 nF do 100 nF","cmc":"0,13 %"},{"name":"103 kHz do 150 kHz","range":"od 50 nF do 100 nF","cmc":"0,19 %"},{"name":"150 kHz do 300 kHz","range":"od 50 nF do 100 nF","cmc":"0,21 %"},{"name":"300 kHz do 500 kHz","range":"od 50 nF do 100 nF","cmc":"0,28 %"},{"name":"500 kHz do 1 MHz","range":"od 50 nF do 100 nF","cmc":"0,39 %"},{"name":"20 Hz do 50 Hz","range":"od 100 nF do 500 nF","cmc":"0,36 %"},{"name":"50 Hz do 100 Hz","range":"od 100 nF do 500 nF","cmc":"0,18 %"},{"name":"100 Hz do 10 kHz","range":"od 100 nF do 500 nF","cmc":"0,12 %"},{"name":"10 kHz do 70 kHz","range":"od 100 nF do 500 nF","cmc":"0,22 %"},{"name":"70 kHz do 100 kHz","range":"od 100 nF do 500 nF","cmc":"0,25 %"},{"name":"100 kHz do 140 kHz","range":"od 100 nF do 500 nF","cmc":"0,27 %"},{"name":"140 kHz do 230 kHz","range":"od 100 nF do 500 nF","cmc":"0,34 %"},{"name":"230 kHz do 280 kHz","range":"od 100 nF do 500 nF","cmc":"0,38 %"},{"name":"280 kHz do 300 kHz","range":"od 100 nF do 500 nF","cmc":"0,40 %"},{"name":"300 kHz do 350 kHz","range":"od 100 nF do 500 nF","cmc":"0,56 %"},{"name":"350 kHz do 400 kHz","range":"od 100 nF do 500 nF","cmc":"0,62 %"},{"name":"400 kHz do 450 kHz","range":"od 100 nF do 500 nF","cmc":"0,68 %"},{"name":"450 kHz do 500 kHz","range":"od 100 nF do 500 nF","cmc":"0,74 %"},{"name":"500 kHz do 600 kHz","range":"od 100 nF do 500 nF","cmc":"0,86 %"},{"name":"600 kHz do 700 kHz","range":"od 100 nF do 500 nF","cmc":"0,97 %"},{"name":"700 kHz do 800 kHz","range":"od 100 nF do 500 nF","cmc":"1,1 %"},{"name":"800 kHz do 1 MHz","range":"od 100 nF do 500 nF","cmc":"1,4 %"},{"name":"20 Hz do 50 Hz","range":"od 500 nF do 1 µF","cmc":"0,36 %"},{"name":"50 Hz do 100 Hz","range":"od 500 nF do 1 µF","cmc":"0,18 %"},{"name":"100 Hz do 10 kHz","range":"od 500 nF do 1 µF","cmc":"0,12 %"},{"name":"10 kHz do 70 kHz","range":"od 500 nF do 1 µF","cmc":"0,22 %"},{"name":"70 kHz do 100 kHz","range":"od 500 nF do 1 µF","cmc":"0,25 %"},{"name":"100 kHz do 120 kHz","range":"od 500 nF do 1 µF","cmc":"0,35 %"},{"name":"120 kHz do 150 kHz","range":"od 500 nF do 1 µF","cmc":"0,40 %"},{"name":"150 kHz do 180 kHz","range":"od 500 nF do 1 µF","cmc":"0,45 %"},{"name":"180 kHz do 220 kHz","range":"od 500 nF do 1 µF","cmc":"0,51 %"},{"name":"220 kHz do 250 kHz","range":"od 500 nF do 1 µF","cmc":"0,56 %"},{"name":"250 kHz do 300 kHz","range":"od 500 nF do 1 µF","cmc":"0,64 %"},{"name":"300 kHz do 350 kHz","range":"od 500 nF do 1 µF","cmc":"0,97 %"},{"name":"350 kHz do 400 kHz","range":"od 500 nF do 1 µF","cmc":"1,1 %"},{"name":"400 kHz do 500 kHz","range":"od 500 nF do 1 µF","cmc":"1,4 %"},{"name":"500 kHz do 600 kHz","range":"od 500 nF do 1 µF","cmc":"1,6 %"},{"name":"600 kHz do 700 kHz","range":"od 500 nF do 1 µF","cmc":"1,8 %"},{"name":"700 kHz do 1 MHz","range":"od 500 nF do 1 µF","cmc":"2,5 %"},{"name":"20 Hz do 50 Hz","range":"od 1 µF do 5 µF","cmc":"0,34 %"},{"name":"50 Hz do 5 kHz","range":"od 1 µF do 5 µF","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 1 µF do 5 µF","cmc":"0,25 %"},{"name":"10 kHz do 15 kHz","range":"od 1 µF do 5 µF","cmc":"0,29 %"},{"name":"15 kHz do 20 kHz","range":"od 1 µF do 5 µF","cmc":"0,33 %"},{"name":"20 kHz do 25 kHz","range":"od 1 µF do 5 µF","cmc":"0,38 %"},{"name":"25 kHz do 30 kHz","range":"od 1 µF do 5 µF","cmc":"0,42 %"},{"name":"30 kHz do 40 kHz","range":"od 1 µF do 5 µF","cmc":"0,33 %"},{"name":"40 kHz do 50 kHz","range":"od 1 µF do 5 µF","cmc":"0,38 %"},{"name":"50 kHz do 60 kHz","range":"od 1 µF do 5 µF","cmc":"0,42 %"},{"name":"60 kHz do 70 kHz","range":"od 1 µF do 5 µF","cmc":"0,46 %"},{"name":"70 kHz do 80 kHz","range":"od 1 µF do 5 µF","cmc":"0,51 %"},{"name":"80 kHz do 90 kHz","range":"od 1 µF do 5 µF","cmc":"0,55 %"},{"name":"90 kHz do 100 kHz","range":"od 1 µF do 5 µF","cmc":"0,59 %"},{"name":"100 kHz do 110 kHz","range":"od 1 µF do 5 µF","cmc":"1,1 %"},{"name":"110 kHz do 140 kHz","range":"od 1 µF do 5 µF","cmc":"1,3 %"},{"name":"140 kHz do 160 kHz","range":"od 1 µF do 5 µF","cmc":"1,5 %"},{"name":"160 kHz do 190 kHz","range":"od 1 µF do 5 µF","cmc":"1,7 %"},{"name":"190 kHz do 210 kHz","range":"od 1 µF do 5 µF","cmc":"1,9 %"},{"name":"210 kHz do 250 kHz","range":"od 1 µF do 5 µF","cmc":"2,2 %"},{"name":"250 kHz do 300 kHz","range":"od 1 µF do 5 µF","cmc":"2,6 %"},{"name":"300 kHz do 350 kHz","range":"od 1 µF do 5 µF","cmc":"4,3 %"},{"name":"350 kHz do 400 kHz","range":"od 1 µF do 5 µF","cmc":"4,9 %"},{"name":"400 kHz do 450 kHz","range":"od 1 µF do 5 µF","cmc":"5,4 %"},{"name":"450 kHz do 500 kHz","range":"od 1 µF do 5 µF","cmc":"6,0 %"},{"name":"20 Hz do 50 Hz","range":"od 5 µF do 10 µF","cmc":"0,34 %"},{"name":"50 Hz do 5 kHz","range":"od 5 µF do 10 µF","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 5 µF do 10 µF","cmc":"0,25 %"},{"name":"10 kHz do 15 kHz","range":"od 5 µF do 10 µF","cmc":"0,29 %"},{"name":"15 kHz do 20 kHz","range":"od 5 µF do 10 µF","cmc":"0,33 %"},{"name":"20 kHz do 25 kHz","range":"od 5 µF do 10 µF","cmc":"0,38 %"},{"name":"25 kHz do 30 kHz","range":"od 5 µF do 10 µF","cmc":"0,42 %"},{"name":"30 kHz do 40 kHz","range":"od 5 µF do 10 µF","cmc":"0,51 %"},{"name":"40 kHz do 50 kHz","range":"od 5 µF do 10 µF","cmc":"0,59 %"},{"name":"50 kHz do 60 kHz","range":"od 5 µF do 10 µF","cmc":"0,68 %"},{"name":"60 kHz do 70 kHz","range":"od 5 µF do 10 µF","cmc":"0,77 %"},{"name":"70 kHz do 80 kHz","range":"od 5 µF do 10 µF","cmc":"0,85 %"},{"name":"80 kHz do 90 kHz","range":"od 5 µF do 10 µF","cmc":"0,94 %"},{"name":"90 kHz do 100 kHz","range":"od 5 µF do 10 µF","cmc":"1,1 %"},{"name":"100 kHz do 110 kHz","range":"od 5 µF do 10 µF","cmc":"2,0 %"},{"name":"110 kHz do 140 kHz","range":"od 5 µF do 10 µF","cmc":"2,4 %"},{"name":"140 kHz do 160 kHz","range":"od 5 µF do 10 µF","cmc":"2,8 %"},{"name":"160 kHz do 190 kHz","range":"od 5 µF do 10 µF","cmc":"3,2 %"},{"name":"190 kHz do 210 kHz","range":"od 5 µF do 10 µF","cmc":"3,6 %"},{"name":"210 kHz do 250 kHz","range":"od 5 µF do 10 µF","cmc":"4,2 %"},{"name":"250 kHz do 300 kHz","range":"od 5 µF do 10 µF","cmc":"5,0 %"},{"name":"20 Hz do 50 Hz","range":"od 10 µF do 20 µF","cmc":"0,34 %"},{"name":"50 Hz do 500 Hz","range":"od 10 µF do 20 µF","cmc":"0,20 %"},{"name":"500 Hz do 700 Hz","range":"od 10 µF do 20 µF","cmc":"0,22 %"},{"name":"700 Hz do 1 kHz","range":"od 10 µF do 20 µF","cmc":"0,25 %"},{"name":"1 kHz do 2 kHz","range":"od 10 µF do 20 µF","cmc":"0,33 %"},{"name":"2 kHz do 3 kHz","range":"od 10 µF do 20 µF","cmc":"0,42 %"},{"name":"3 kHz do 4 kHz","range":"od 10 µF do 20 µF","cmc":"0,51 %"},{"name":"4 kHz do 5 kHz","range":"od 10 µF do 20 µF","cmc":"0,59 %"},{"name":"5 kHz do 6 kHz","range":"od 10 µF do 20 µF","cmc":"0,68 %"},{"name":"6 kHz do 7 kHz","range":"od 10 µF do 20 µF","cmc":"0,77 %"},{"name":"7 kHz do 8 kHz","range":"od 10 µF do 20 µF","cmc":"0,85 %"},{"name":"8 kHz do 9 kHz","range":"od 10 µF do 20 µF","cmc":"0,94 %"},{"name":"9 kHz do 10 kHz","range":"od 10 µF do 20 µF","cmc":"1,1 %"},{"name":"10 kHz do 15 kHz","range":"od 10 µF do 20 µF","cmc":"1,5 %"},{"name":"15 kHz do 20 kHz","range":"od 10 µF do 20 µF","cmc":"1,9 %"},{"name":"20 kHz do 25 kHz","range":"od 10 µF do 20 µF","cmc":"2,4 %"},{"name":"25 kHz do 30 kHz","range":"od 10 µF do 20 µF","cmc":"2,8 %"},{"name":"30 kHz do 40 kHz","range":"od 10 µF do 20 µF","cmc":"1,9 %"},{"name":"40 kHz do 50 kHz","range":"od 10 µF do 20 µF","cmc":"2,4 %"},{"name":"50 kHz do 60 kHz","range":"od 10 µF do 20 µF","cmc":"2,8 %"},{"name":"60 kHz do 70 kHz","range":"od 10 µF do 20 µF","cmc":"3,2 %"},{"name":"70 kHz do 80 kHz","range":"od 10 µF do 20 µF","cmc":"3,7 %"},{"name":"80 kHz do 90 kHz","range":"od 10 µF do 20 µF","cmc":"4,1 %"},{"name":"90 kHz do 100 kHz","range":"od 10 µF do 20 µF","cmc":"4,6 %"},{"name":"20 Hz do 50 Hz","range":"od 20 µF do 50 µF","cmc":"0,34 %"},{"name":"50 Hz do 500 Hz","range":"od 20 µF do 50 µF","cmc":"0,20 %"},{"name":"500 Hz do 700 Hz","range":"od 20 µF do 50 µF","cmc":"0,22 %"},{"name":"700 Hz do 1 kHz","range":"od 20 µF do 50 µF","cmc":"0,25 %"},{"name":"1 kHz do 2 kHz","range":"od 20 µF do 50 µF","cmc":"0,33 %"},{"name":"2 kHz do 3 kHz","range":"od 20 µF do 50 µF","cmc":"0,42 %"},{"name":"3 kHz do 4 kHz","range":"od 20 µF do 50 µF","cmc":"0,51 %"},{"name":"4 kHz do 5 kHz","range":"od 20 µF do 50 µF","cmc":"0,59 %"},{"name":"5 kHz do 6 kHz","range":"od 20 µF do 50 µF","cmc":"0,68 %"},{"name":"6 kHz do 7 kHz","range":"od 20 µF do 50 µF","cmc":"0,77 %"},{"name":"7 kHz do 8 kHz","range":"od 20 µF do 50 µF","cmc":"0,85 %"},{"name":"8 kHz do 9 kHz","range":"od 20 µF do 50 µF","cmc":"0,94 %"},{"name":"9 kHz do 10 kHz","range":"od 20 µF do 50 µF","cmc":"1,1 %"},{"name":"10 kHz do 15 kHz","range":"od 20 µF do 50 µF","cmc":"1,5 %"},{"name":"15 kHz do 20 kHz","range":"od 20 µF do 50 µF","cmc":"1,9 %"},{"name":"20 kHz do 25 kHz","range":"od 20 µF do 50 µF","cmc":"2,4 %"},{"name":"25 kHz do 30 kHz","range":"od 20 µF do 50 µF","cmc":"2,8 %"},{"name":"30 kHz do 40 kHz","range":"od 20 µF do 50 µF","cmc":"1,9 %"},{"name":"40 kHz do 50 kHz","range":"od 20 µF do 50 µF","cmc":"2,4 %"},{"name":"20 Hz do 50 Hz","range":"od 50 µF do 100 µF","cmc":"0,34 %"},{"name":"50 Hz do 500 Hz","range":"od 50 µF do 100 µF","cmc":"0,20 %"},{"name":"500 Hz do 700 Hz","range":"od 50 µF do 100 µF","cmc":"0,22 %"},{"name":"700 Hz do 1 kHz","range":"od 50 µF do 100 µF","cmc":"0,25 %"},{"name":"1 kHz do 2 kHz","range":"od 50 µF do 100 µF","cmc":"0,33 %"},{"name":"2 kHz do 3 kHz","range":"od 50 µF do 100 µF","cmc":"0,42 %"},{"name":"3 kHz do 4 kHz","range":"od 50 µF do 100 µF","cmc":"0,51 %"},{"name":"4 kHz do 5 kHz","range":"od 50 µF do 100 µF","cmc":"0,59 %"},{"name":"5 kHz do 6 kHz","range":"od 50 µF do 100 µF","cmc":"0,68 %"},{"name":"6 kHz do 7 kHz","range":"od 50 µF do 100 µF","cmc":"0,77 %"},{"name":"7 kHz do 8 kHz","range":"od 50 µF do 100 µF","cmc":"0,85 %"},{"name":"8 kHz do 9 kHz","range":"od 50 µF do 100 µF","cmc":"0,94 %"},{"name":"9 kHz do 10 kHz","range":"od 50 µF do 100 µF","cmc":"1,1 %"},{"name":"10 kHz do 15 kHz","range":"od 50 µF do 100 µF","cmc":"1,5 %"},{"name":"15 kHz do 20 kHz","range":"od 50 µF do 100 µF","cmc":"1,9 %"},{"name":"20 Hz do 50 Hz","range":"od 100 µF do 500 µF","cmc":"0,44 %"},{"name":"50 Hz do 70 Hz","range":"od 100 µF do 500 µF","cmc":"0,29 %"},{"name":"70 Hz do 200 Hz","range":"od 100 µF do 500 µF","cmc":"0,33 %"},{"name":"200 Hz do 300 Hz","range":"od 100 µF do 500 µF","cmc":"0,42 %"},{"name":"300 Hz do 400 Hz","range":"od 100 µF do 500 µF","cmc":"0,51 %"},{"name":"400 Hz do 500 Hz","range":"od 100 µF do 500 µF","cmc":"0,59 %"},{"name":"500 Hz do 600 Hz","range":"od 100 µF do 500 µF","cmc":"0,68 %"},{"name":"600 Hz do 700 Hz","range":"od 100 µF do 500 µF","cmc":"0,77 %"},{"name":"700 Hz do 800 Hz","range":"od 100 µF do 500 µF","cmc":"0,85 %"},{"name":"800 Hz do 900 Hz","range":"od 100 µF do 500 µF","cmc":"0,94 %"},{"name":"900 Hz do 2 kHz","range":"od 100 µF do 500 µF","cmc":"1,1 %"},{"name":"2 kHz do 3 kHz","range":"od 100 µF do 500 µF","cmc":"1,5 %"},{"name":"3 kHz do 4 kHz","range":"od 100 µF do 500 µF","cmc":"1,9 %"},{"name":"4 kHz do 5 kHz","range":"od 100 µF do 500 µF","cmc":"2,4 %"},{"name":"20 Hz do 50 Hz","range":"od 500 µF do 1 mF","cmc":"0,44 %"},{"name":"50 Hz do 70 Hz","range":"od 500 µF do 1 mF","cmc":"0,29 %"},{"name":"70 Hz do 200 Hz","range":"od 500 µF do 1 mF","cmc":"0,33 %"},{"name":"200 Hz do 300 Hz","range":"od 500 µF do 1 mF","cmc":"0,42 %"},{"name":"300 Hz do 400 Hz","range":"od 500 µF do 1 mF","cmc":"0,51 %"},{"name":"400 Hz do 500 Hz","range":"od 500 µF do 1 mF","cmc":"0,59 %"},{"name":"500 Hz do 600 Hz","range":"od 500 µF do 1 mF","cmc":"0,68 %"},{"name":"600 Hz do 700 Hz","range":"od 500 µF do 1 mF","cmc":"0,77 %"},{"name":"700 Hz do 800 Hz","range":"od 500 µF do 1 mF","cmc":"0,85 %"},{"name":"800 Hz do 900 Hz","range":"od 500 µF do 1 mF","cmc":"0,94 %"},{"name":"900 Hz do 1 kHz","range":"od 500 µF do 1 mF","cmc":"1,1 %"},{"name":"1 kHz do 2 kHz","range":"od 500 µF do 1 mF","cmc":"1,9 %"},{"name":"20 Hz do 30 Hz","range":"od 1 mF do 5 mF","cmc":"0,70 %"},{"name":"30 Hz do 40 Hz","range":"od 1 mF do 5 mF","cmc":"0,78 %"},{"name":"40 Hz do 80 Hz","range":"od 1 mF do 5 mF","cmc":"0,89 %"},{"name":"80 Hz do 90 Hz","range":"od 1 mF do 5 mF","cmc":"0,96 %"},{"name":"90 Hz do 160 Hz","range":"od 1 mF do 5 mF","cmc":"1,1 %"},{"name":"160 Hz do 300 Hz","range":"od 1 mF do 5 mF","cmc":"1,7 %"},{"name":"300 Hz do 400 Hz","range":"od 1 mF do 5 mF","cmc":"2,1 %"},{"name":"400 Hz do 500 Hz","range":"od 1 mF do 5 mF","cmc":"2,6 %"},{"name":"500 Hz do 600 Hz","range":"od 1 mF do 5 mF","cmc":"3,0 %"},{"name":"600 Hz do 700 Hz","range":"od 1 mF do 5 mF","cmc":"3,4 %"},{"name":"700 Hz do 800 Hz","range":"od 1 mF do 5 mF","cmc":"3,9 %"},{"name":"800 Hz do 900 Hz","range":"od 1 mF do 5 mF","cmc":"4,3 %"},{"name":"900 Hz do 1 kHz","range":"od 1 mF do 5 mF","cmc":"4,7 %"},{"name":"50 Hz do 60 Hz","range":"od 5 mF do 10 mF","cmc":"1,4 %"},{"name":"60 Hz do 160 Hz","range":"od 5 mF do 10 mF","cmc":"1,9 %"},{"name":"160 Hz do 220 Hz","range":"od 5 mF do 10 mF","cmc":"2,3 %"},{"name":"220 Hz do 300 Hz","range":"od 5 mF do 10 mF","cmc":"3,0 %"}],"parameters_en":[{"name":"10 kHz to 15 kHz","range":"1 pF to 5 pF","cmc":"2,2 %"},{"name":"15 kHz to 20 kHz","range":"1 pF to 5 pF","cmc":"1,5 %"},{"name":"20 kHz to 25 kHz","range":"1 pF to 5 pF","cmc":"1,2 %"},{"name":"25 kHz to 30 kHz","range":"1 pF to 5 pF","cmc":"0,94 %"},{"name":"30 kHz to 40 kHz","range":"1 pF to 5 pF","cmc":"0,81 %"},{"name":"40 kHz to 50 kHz","range":"1 pF to 5 pF","cmc":"0,65 %"},{"name":"50 kHz to 60 kHz","range":"1 pF to 5 pF","cmc":"0,55 %"},{"name":"60 kHz to 70 kHz","range":"1 pF to 5 pF","cmc":"0,49 %"},{"name":"70 kHz to 80 kHz","range":"1 pF to 5 pF","cmc":"0,44 %"},{"name":"80 kHz to 100 kHz","range":"1 pF to 5 pF","cmc":"0,40 %"},{"name":"100 kHz to 110 kHz","range":"1 pF to 5 pF","cmc":"0,75 %"},{"name":"110 kHz to 120 kHz","range":"1 pF to 5 pF","cmc":"0,69 %"},{"name":"120 kHz to 130 kHz","range":"1 pF to 5 pF","cmc":"0,65 %"},{"name":"130 kHz to 140 kHz","range":"1 pF to 5 pF","cmc":"0,61 %"},{"name":"140 kHz to 150 kHz","range":"1 pF to 5 pF","cmc":"0,58 %"},{"name":"150 kHz to 170 kHz","range":"1 pF to 5 pF","cmc":"0,55 %"},{"name":"170 kHz to 200 kHz","range":"1 pF to 5 pF","cmc":"0,50 %"},{"name":"200 kHz to 250 kHz","range":"1 pF to 5 pF","cmc":"0,45 %"},{"name":"250 kHz to 300 kHz","range":"1 pF to 5 pF","cmc":"0,39 %"},{"name":"300 kHz to 350 kHz","range":"1 pF to 5 pF","cmc":"0,81 %"},{"name":"350 kHz to 400 kHz","range":"1 pF to 5 pF","cmc":"0,72 %"},{"name":"400 kHz to 450 kHz","range":"1 pF to 5 pF","cmc":"0,65 %"},{"name":"450 kHz to 500 kHz","range":"1 pF to 5 pF","cmc":"0,59 %"},{"name":"500 kHz to 600 kHz","range":"1 pF to 5 pF","cmc":"0,55 %"},{"name":"600 kHz to 700 kHz","range":"1 pF to 5 pF","cmc":"0,49 %"},{"name":"700 kHz to 800 kHz","range":"1 pF to 5 pF","cmc":"0,44 %"},{"name":"800 kHz to 1 MHz","range":"1 pF to 5 pF","cmc":"0,40 %"},{"name":"1 kHz to 2 kHz","range":"5 pF to 10 pF","cmc":"4,1 %"},{"name":"2 kHz to 3 kHz","range":"5 pF to 10 pF","cmc":"2,2 %"},{"name":"3 kHz to 4 kHz","range":"5 pF to 10 pF","cmc":"1,5 %"},{"name":"4 kHz to 5 kHz","range":"5 pF to 10 pF","cmc":"1,2 %"},{"name":"5 kHz to 6 kHz","range":"5 pF to 10 pF","cmc":"0,94 %"},{"name":"6 kHz to 7 kHz","range":"5 pF to 10 pF","cmc":"0,81 %"},{"name":"7 kHz to 8 kHz","range":"5 pF to 10 pF","cmc":"0,72 %"},{"name":"8 kHz to 9 kHz","range":"5 pF to 10 pF","cmc":"0,65 %"},{"name":"9 kHz to 10 kHz","range":"5 pF to 10 pF","cmc":"0,59 %"},{"name":"10 kHz to 15 kHz","range":"5 pF to 10 pF","cmc":"0,55 %"},{"name":"15 kHz to 20 kHz","range":"5 pF to 10 pF","cmc":"0,42 %"},{"name":"20 kHz to 25 kHz","range":"5 pF to 10 pF","cmc":"0,36 %"},{"name":"25 kHz to 30 kHz","range":"5 pF to 10 pF","cmc":"0,32 %"},{"name":"30 kHz to 1 MHz","range":"5 pF to 10 pF","cmc":"0,29 %"},{"name":"500 Hz to 600 Hz","range":"10 pF to 50 pF","cmc":"4,3 %"},{"name":"600 Hz to 700 Hz","range":"10 pF to 50 pF","cmc":"3,7 %"},{"name":"700 Hz to 800 Hz","range":"10 pF to 50 pF","cmc":"3,2 %"},{"name":"800 Hz to 900 Hz","range":"10 pF to 50 pF","cmc":"2,8 %"},{"name":"900 Hz to 1 kHz","range":"10 pF to 50 pF","cmc":"2,6 %"},{"name":"1 kHz to 2 kHz","range":"10 pF to 50 pF","cmc":"2,2 %"},{"name":"2 kHz to 3 kHz","range":"10 pF to 50 pF","cmc":"1,2 %"},{"name":"3 kHz to 4 kHz","range":"10 pF to 50 pF","cmc":"0,81 %"},{"name":"4 kHz to 5 kHz","range":"10 pF to 50 pF","cmc":"0,65 %"},{"name":"5 kHz to 6 kHz","range":"10 pF to 50 pF","cmc":"0,55 %"},{"name":"6 kHz to 7 kHz","range":"10 pF to 50 pF","cmc":"0,49 %"},{"name":"7 kHz to 8 kHz","range":"10 pF to 50 pF","cmc":"0,44 %"},{"name":"8 kHz to 9 kHz","range":"10 pF to 50 pF","cmc":"0,40 %"},{"name":"9 kHz to 10 kHz","range":"10 pF to 50 pF","cmc":"0,38 %"},{"name":"10 kHz to 15 kHz","range":"10 pF to 50 pF","cmc":"0,36 %"},{"name":"15 kHz to 20 kHz","range":"10 pF to 50 pF","cmc":"0,29 %"},{"name":"20 kHz to 1 MHz","range":"10 pF to 50 pF","cmc":"0,26 %"},{"name":"100 Hz to 200 Hz","range":"50 pF to 100 pF","cmc":"4,3 %"},{"name":"200 Hz to 300 Hz","range":"50 pF to 100 pF","cmc":"2,3 %"},{"name":"300 Hz to 400 Hz","range":"50 pF to 100 pF","cmc":"1,7 %"},{"name":"400 Hz to 500 Hz","range":"50 pF to 100 pF","cmc":"1,4 %"},{"name":"500 Hz to 600 Hz","range":"50 pF to 100 pF","cmc":"1,2 %"},{"name":"600 Hz to 700 Hz","range":"50 pF to 100 pF","cmc":"0,99 %"},{"name":"700 Hz to 800 Hz","range":"50 pF to 100 pF","cmc":"0,89 %"},{"name":"800 Hz to 900 Hz","range":"50 pF to 100 pF","cmc":"0,82 %"},{"name":"900 Hz to 1 kHz","range":"50 pF to 100 pF","cmc":"0,77 %"},{"name":"1 kHz to 2 kHz","range":"50 pF to 100 pF","cmc":"0,55 %"},{"name":"2 kHz to 3 kHz","range":"50 pF to 100 pF","cmc":"0,36 %"},{"name":"3 kHz to 4 kHz","range":"50 pF to 100 pF","cmc":"0,29 %"},{"name":"4 kHz to 5 kHz","range":"50 pF to 100 pF","cmc":"0,26 %"},{"name":"5 kHz to 1 MHz","range":"50 pF to 100 pF","cmc":"0,24 %"},{"name":"50 Hz to 60 Hz","range":"100 pF to 500 pF","cmc":"9,9 %"},{"name":"60 Hz to 70 Hz","range":"100 pF to 500 pF","cmc":"7,9 %"},{"name":"70 Hz to 80 Hz","range":"100 pF to 500 pF","cmc":"6,5 %"},{"name":"80 Hz to 90 Hz","range":"100 pF to 500 pF","cmc":"5,6 %"},{"name":"90 Hz to 100 Hz","range":"100 pF to 500 pF","cmc":"4,9 %"},{"name":"100 Hz to 160 Hz","range":"100 pF to 500 pF","cmc":"2,3 %"},{"name":"160 Hz to 200 Hz","range":"100 pF to 500 pF","cmc":"1,4 %"},{"name":"200 Hz to 300 Hz","range":"100 pF to 500 pF","cmc":"1,2 %"},{"name":"300 Hz to 400 Hz","range":"100 pF to 500 pF","cmc":"0,81 %"},{"name":"400 Hz to 500 Hz","range":"100 pF to 500 pF","cmc":"0,65 %"},{"name":"500 Hz to 600 Hz","range":"100 pF to 500 pF","cmc":"0,55 %"},{"name":"600 Hz to 700 Hz","range":"100 pF to 500 pF","cmc":"0,49 %"},{"name":"700 Hz to 800 Hz","range":"100 pF to 500 pF","cmc":"0,44 %"},{"name":"800 Hz to 900 Hz","range":"100 pF to 500 pF","cmc":"0,40 %"},{"name":"900 Hz to 1 kHz","range":"100 pF to 500 pF","cmc":"0,38 %"},{"name":"1 kHz to 2 kHz","range":"100 pF to 500 pF","cmc":"0,36 %"},{"name":"2 kHz to 3 kHz","range":"100 pF to 500 pF","cmc":"0,26 %"},{"name":"3 kHz to 4 kHz","range":"100 pF to 500 pF","cmc":"0,23 %"},{"name":"4 kHz to 5 kHz","range":"100 pF to 500 pF","cmc":"0,21 %"},{"name":"5 kHz to 1 MHz","range":"100 pF to 500 pF","cmc":"0,17 %"},{"name":"50 Hz to 60 Hz","range":"500 pF to 1 nF","cmc":"2,3 %"},{"name":"60 Hz to 70 Hz","range":"500 pF to 1 nF","cmc":"1,9 %"},{"name":"70 Hz to 80 Hz","range":"500 pF to 1 nF","cmc":"1,6 %"},{"name":"80 Hz to 100 Hz","range":"500 pF to 1 nF","cmc":"1,4 %"},{"name":"100 Hz to 160 Hz","range":"500 pF to 1 nF","cmc":"0,72 %"},{"name":"160 Hz to 200 Hz","range":"500 pF to 1 nF","cmc":"0,40 %"},{"name":"200 Hz to 300 Hz","range":"500 pF to 1 nF","cmc":"0,36 %"},{"name":"300 Hz to 400 Hz","range":"500 pF to 1 nF","cmc":"0,29 %"},{"name":"400 Hz to 500 Hz","range":"500 pF to 1 nF","cmc":"0,26 %"},{"name":"500 Hz to 700 Hz","range":"500 pF to 1 nF","cmc":"0,24 %"},{"name":"700 Hz to 1 kHz","range":"500 pF to 1 nF","cmc":"0,22 %"},{"name":"1 kHz to 2 kHz","range":"500 pF to 1 nF","cmc":"0,36 %"},{"name":"2 kHz to 3 kHz","range":"500 pF to 1 nF","cmc":"0,26 %"},{"name":"3 kHz to 4 kHz","range":"500 pF to 1 nF","cmc":"0,23 %"},{"name":"4 kHz to 5 kHz","range":"500 pF to 1 nF","cmc":"0,21 %"},{"name":"5 kHz to 1 MHz","range":"500 pF to 1 nF","cmc":"0,17 %"},{"name":"20 Hz to 30 Hz","range":"1 nF to 5 nF","cmc":"3,6 %"},{"name":"30 Hz to 40 Hz","range":"1 nF to 5 nF","cmc":"2,2 %"},{"name":"40 Hz to 50 Hz","range":"1 nF to 5 nF","cmc":"1,6 %"},{"name":"50 Hz to 60 Hz","range":"1 nF to 5 nF","cmc":"1,2 %"},{"name":"60 Hz to 70 Hz","range":"1 nF to 5 nF","cmc":"0,91 %"},{"name":"70 Hz to 80 Hz","range":"1 nF to 5 nF","cmc":"0,77 %"},{"name":"80 Hz to 90 Hz","range":"1 nF to 5 nF","cmc":"0,68 %"},{"name":"90 Hz to 100 Hz","range":"1 nF to 5 nF","cmc":"0,61 %"},{"name":"100 Hz to 200 Hz","range":"1 nF to 5 nF","cmc":"0,36 %"},{"name":"200 Hz to 300 Hz","range":"1 nF to 5 nF","cmc":"0,26 %"},{"name":"300 Hz to 500 Hz","range":"1 nF to 5 nF","cmc":"0,23 %"},{"name":"500 Hz to 1 MHz","range":"1 nF to 5 nF","cmc":"0,15 %"},{"name":"20 Hz to 30 Hz","range":"5 nF to 10 nF","cmc":"0,97 %"},{"name":"30 Hz to 40 Hz","range":"5 nF to 10 nF","cmc":"0,70 %"},{"name":"40 Hz to 50 Hz","range":"5 nF to 10 nF","cmc":"0,58 %"},{"name":"50 Hz to 60 Hz","range":"5 nF to 10 nF","cmc":"0,35 %"},{"name":"60 Hz to 70 Hz","range":"5 nF to 10 nF","cmc":"0,31 %"},{"name":"70 Hz to 100 Hz","range":"5 nF to 10 nF","cmc":"0,28 %"},{"name":"100 Hz to 400 Hz","range":"5 nF to 10 nF","cmc":"0,20 %"},{"name":"400 Hz to 500 Hz","range":"5 nF to 10 nF","cmc":"0,17 %"},{"name":"500 Hz to 1 MHz","range":"5 nF to 10 nF","cmc":"0,13 %"},{"name":"20 Hz to 30 Hz","range":"10 nF to 50 nF","cmc":"0,65 %"},{"name":"30 Hz to 40 Hz","range":"10 nF to 50 nF","cmc":"0,52 %"},{"name":"40 Hz to 50 Hz","range":"10 nF to 50 nF","cmc":"0,46 %"},{"name":"50 Hz to 70 Hz","range":"10 nF to 50 nF","cmc":"0,26 %"},{"name":"70 Hz to 100 Hz","range":"10 nF to 50 nF","cmc":"0,22 %"},{"name":"100 Hz to 103 kHz","range":"10 nF to 50 nF","cmc":"0,13 %"},{"name":"103 kHz to 150 kHz","range":"10 nF to 50 nF","cmc":"0,19 %"},{"name":"150 kHz to 300 kHz","range":"10 nF to 50 nF","cmc":"0,21 %"},{"name":"300 kHz to 500 kHz","range":"10 nF to 50 nF","cmc":"0,28 %"},{"name":"500 kHz to 1 MHz","range":"10 nF to 50 nF","cmc":"0,39 %"},{"name":"20 Hz to 40 Hz","range":"50 nF to 100 nF","cmc":"0,40 %"},{"name":"40 Hz to 50 Hz","range":"50 nF to 100 nF","cmc":"0,36 %"},{"name":"50 Hz to 70 Hz","range":"50 nF to 100 nF","cmc":"0,26 %"},{"name":"70 Hz to 100 Hz","range":"50 nF to 100 nF","cmc":"0,22 %"},{"name":"100 Hz to 103 kHz","range":"50 nF to 100 nF","cmc":"0,13 %"},{"name":"103 kHz to 150 kHz","range":"50 nF to 100 nF","cmc":"0,19 %"},{"name":"150 kHz to 300 kHz","range":"50 nF to 100 nF","cmc":"0,21 %"},{"name":"300 kHz to 500 kHz","range":"50 nF to 100 nF","cmc":"0,28 %"},{"name":"500 kHz to 1 MHz","range":"50 nF to 100 nF","cmc":"0,39 %"},{"name":"20 Hz to 50 Hz","range":"100 nF to 500 nF","cmc":"0,36 %"},{"name":"50 Hz to 100 Hz","range":"100 nF to 500 nF","cmc":"0,18 %"},{"name":"100 Hz to 10 kHz","range":"100 nF to 500 nF","cmc":"0,12 %"},{"name":"10 kHz to 70 kHz","range":"100 nF to 500 nF","cmc":"0,22 %"},{"name":"70 kHz to 100 kHz","range":"100 nF to 500 nF","cmc":"0,25 %"},{"name":"100 kHz to 140 kHz","range":"100 nF to 500 nF","cmc":"0,27 %"},{"name":"140 kHz to 230 kHz","range":"100 nF to 500 nF","cmc":"0,34 %"},{"name":"230 kHz to 280 kHz","range":"100 nF to 500 nF","cmc":"0,38 %"},{"name":"280 kHz to 300 kHz","range":"100 nF to 500 nF","cmc":"0,40 %"},{"name":"300 kHz to 350 kHz","range":"100 nF to 500 nF","cmc":"0,56 %"},{"name":"350 kHz to 400 kHz","range":"100 nF to 500 nF","cmc":"0,62 %"},{"name":"400 kHz to 450 kHz","range":"100 nF to 500 nF","cmc":"0,68 %"},{"name":"450 kHz to 500 kHz","range":"100 nF to 500 nF","cmc":"0,74 %"},{"name":"500 kHz to 600 kHz","range":"100 nF to 500 nF","cmc":"0,86 %"},{"name":"600 kHz to 700 kHz","range":"100 nF to 500 nF","cmc":"0,97 %"},{"name":"700 kHz to 800 kHz","range":"100 nF to 500 nF","cmc":"1,1 %"},{"name":"800 kHz to 1 MHz","range":"100 nF to 500 nF","cmc":"1,4 %"},{"name":"20 Hz to 50 Hz","range":"500 nF to 1 µF","cmc":"0,36 %"},{"name":"50 Hz to 100 Hz","range":"500 nF to 1 µF","cmc":"0,18 %"},{"name":"100 Hz to 10 kHz","range":"500 nF to 1 µF","cmc":"0,12 %"},{"name":"10 kHz to 70 kHz","range":"500 nF to 1 µF","cmc":"0,22 %"},{"name":"70 kHz to 100 kHz","range":"500 nF to 1 µF","cmc":"0,25 %"},{"name":"100 kHz to 120 kHz","range":"500 nF to 1 µF","cmc":"0,35 %"},{"name":"120 kHz to 150 kHz","range":"500 nF to 1 µF","cmc":"0,40 %"},{"name":"150 kHz to 180 kHz","range":"500 nF to 1 µF","cmc":"0,45 %"},{"name":"180 kHz to 220 kHz","range":"500 nF to 1 µF","cmc":"0,51 %"},{"name":"220 kHz to 250 kHz","range":"500 nF to 1 µF","cmc":"0,56 %"},{"name":"250 kHz to 300 kHz","range":"500 nF to 1 µF","cmc":"0,64 %"},{"name":"300 kHz to 350 kHz","range":"500 nF to 1 µF","cmc":"0,97 %"},{"name":"350 kHz to 400 kHz","range":"500 nF to 1 µF","cmc":"1,1 %"},{"name":"400 kHz to 500 kHz","range":"500 nF to 1 µF","cmc":"1,4 %"},{"name":"500 kHz to 600 kHz","range":"500 nF to 1 µF","cmc":"1,6 %"},{"name":"600 kHz to 700 kHz","range":"500 nF to 1 µF","cmc":"1,8 %"},{"name":"700 kHz to 1 MHz","range":"500 nF to 1 µF","cmc":"2,5 %"},{"name":"20 Hz to 50 Hz","range":"1 µF to 5 µF","cmc":"0,34 %"},{"name":"50 Hz to 5 kHz","range":"1 µF to 5 µF","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"1 µF to 5 µF","cmc":"0,25 %"},{"name":"10 kHz to 15 kHz","range":"1 µF to 5 µF","cmc":"0,29 %"},{"name":"15 kHz to 20 kHz","range":"1 µF to 5 µF","cmc":"0,33 %"},{"name":"20 kHz to 25 kHz","range":"1 µF to 5 µF","cmc":"0,38 %"},{"name":"25 kHz to 30 kHz","range":"1 µF to 5 µF","cmc":"0,42 %"},{"name":"30 kHz to 40 kHz","range":"1 µF to 5 µF","cmc":"0,33 %"},{"name":"40 kHz to 50 kHz","range":"1 µF to 5 µF","cmc":"0,38 %"},{"name":"50 kHz to 60 kHz","range":"1 µF to 5 µF","cmc":"0,42 %"},{"name":"60 kHz to 70 kHz","range":"1 µF to 5 µF","cmc":"0,46 %"},{"name":"70 kHz to 80 kHz","range":"1 µF to 5 µF","cmc":"0,51 %"},{"name":"80 kHz to 90 kHz","range":"1 µF to 5 µF","cmc":"0,55 %"},{"name":"90 kHz to 100 kHz","range":"1 µF to 5 µF","cmc":"0,59 %"},{"name":"100 kHz to 110 kHz","range":"1 µF to 5 µF","cmc":"1,1 %"},{"name":"110 kHz to 140 kHz","range":"1 µF to 5 µF","cmc":"1,3 %"},{"name":"140 kHz to 160 kHz","range":"1 µF to 5 µF","cmc":"1,5 %"},{"name":"160 kHz to 190 kHz","range":"1 µF to 5 µF","cmc":"1,7 %"},{"name":"190 kHz to 210 kHz","range":"1 µF to 5 µF","cmc":"1,9 %"},{"name":"210 kHz to 250 kHz","range":"1 µF to 5 µF","cmc":"2,2 %"},{"name":"250 kHz to 300 kHz","range":"1 µF to 5 µF","cmc":"2,6 %"},{"name":"300 kHz to 350 kHz","range":"1 µF to 5 µF","cmc":"4,3 %"},{"name":"350 kHz to 400 kHz","range":"1 µF to 5 µF","cmc":"4,9 %"},{"name":"400 kHz to 450 kHz","range":"1 µF to 5 µF","cmc":"5,4 %"},{"name":"450 kHz to 500 kHz","range":"1 µF to 5 µF","cmc":"6,0 %"},{"name":"20 Hz to 50 Hz","range":"5 µF to 10 µF","cmc":"0,34 %"},{"name":"50 Hz to 5 kHz","range":"5 µF to 10 µF","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"5 µF to 10 µF","cmc":"0,25 %"},{"name":"10 kHz to 15 kHz","range":"5 µF to 10 µF","cmc":"0,29 %"},{"name":"15 kHz to 20 kHz","range":"5 µF to 10 µF","cmc":"0,33 %"},{"name":"20 kHz to 25 kHz","range":"5 µF to 10 µF","cmc":"0,38 %"},{"name":"25 kHz to 30 kHz","range":"5 µF to 10 µF","cmc":"0,42 %"},{"name":"30 kHz to 40 kHz","range":"5 µF to 10 µF","cmc":"0,51 %"},{"name":"40 kHz to 50 kHz","range":"5 µF to 10 µF","cmc":"0,59 %"},{"name":"50 kHz to 60 kHz","range":"5 µF to 10 µF","cmc":"0,68 %"},{"name":"60 kHz to 70 kHz","range":"5 µF to 10 µF","cmc":"0,77 %"},{"name":"70 kHz to 80 kHz","range":"5 µF to 10 µF","cmc":"0,85 %"},{"name":"80 kHz to 90 kHz","range":"5 µF to 10 µF","cmc":"0,94 %"},{"name":"90 kHz to 100 kHz","range":"5 µF to 10 µF","cmc":"1,1 %"},{"name":"100 kHz to 110 kHz","range":"5 µF to 10 µF","cmc":"2,0 %"},{"name":"110 kHz to 140 kHz","range":"5 µF to 10 µF","cmc":"2,4 %"},{"name":"140 kHz to 160 kHz","range":"5 µF to 10 µF","cmc":"2,8 %"},{"name":"160 kHz to 190 kHz","range":"5 µF to 10 µF","cmc":"3,2 %"},{"name":"190 kHz to 210 kHz","range":"5 µF to 10 µF","cmc":"3,6 %"},{"name":"210 kHz to 250 kHz","range":"5 µF to 10 µF","cmc":"4,2 %"},{"name":"250 kHz to 300 kHz","range":"5 µF to 10 µF","cmc":"5,0 %"},{"name":"20 Hz to 50 Hz","range":"10 µF to 20 µF","cmc":"0,34 %"},{"name":"50 Hz to 500 Hz","range":"10 µF to 20 µF","cmc":"0,20 %"},{"name":"500 Hz to 700 Hz","range":"10 µF to 20 µF","cmc":"0,22 %"},{"name":"700 Hz to 1 kHz","range":"10 µF to 20 µF","cmc":"0,25 %"},{"name":"1 kHz to 2 kHz","range":"10 µF to 20 µF","cmc":"0,33 %"},{"name":"2 kHz to 3 kHz","range":"10 µF to 20 µF","cmc":"0,42 %"},{"name":"3 kHz to 4 kHz","range":"10 µF to 20 µF","cmc":"0,51 %"},{"name":"4 kHz to 5 kHz","range":"10 µF to 20 µF","cmc":"0,59 %"},{"name":"5 kHz to 6 kHz","range":"10 µF to 20 µF","cmc":"0,68 %"},{"name":"6 kHz to 7 kHz","range":"10 µF to 20 µF","cmc":"0,77 %"},{"name":"7 kHz to 8 kHz","range":"10 µF to 20 µF","cmc":"0,85 %"},{"name":"8 kHz to 9 kHz","range":"10 µF to 20 µF","cmc":"0,94 %"},{"name":"9 kHz to 10 kHz","range":"10 µF to 20 µF","cmc":"1,1 %"},{"name":"10 kHz to 15 kHz","range":"10 µF to 20 µF","cmc":"1,5 %"},{"name":"15 kHz to 20 kHz","range":"10 µF to 20 µF","cmc":"1,9 %"},{"name":"20 kHz to 25 kHz","range":"10 µF to 20 µF","cmc":"2,4 %"},{"name":"25 kHz to 30 kHz","range":"10 µF to 20 µF","cmc":"2,8 %"},{"name":"30 kHz to 40 kHz","range":"10 µF to 20 µF","cmc":"1,9 %"},{"name":"40 kHz to 50 kHz","range":"10 µF to 20 µF","cmc":"2,4 %"},{"name":"50 kHz to 60 kHz","range":"10 µF to 20 µF","cmc":"2,8 %"},{"name":"60 kHz to 70 kHz","range":"10 µF to 20 µF","cmc":"3,2 %"},{"name":"70 kHz to 80 kHz","range":"10 µF to 20 µF","cmc":"3,7 %"},{"name":"80 kHz to 90 kHz","range":"10 µF to 20 µF","cmc":"4,1 %"},{"name":"90 kHz to 100 kHz","range":"10 µF to 20 µF","cmc":"4,6 %"},{"name":"20 Hz to 50 Hz","range":"20 µF to 50 µF","cmc":"0,34 %"},{"name":"50 Hz to 500 Hz","range":"20 µF to 50 µF","cmc":"0,20 %"},{"name":"500 Hz to 700 Hz","range":"20 µF to 50 µF","cmc":"0,22 %"},{"name":"700 Hz to 1 kHz","range":"20 µF to 50 µF","cmc":"0,25 %"},{"name":"1 kHz to 2 kHz","range":"20 µF to 50 µF","cmc":"0,33 %"},{"name":"2 kHz to 3 kHz","range":"20 µF to 50 µF","cmc":"0,42 %"},{"name":"3 kHz to 4 kHz","range":"20 µF to 50 µF","cmc":"0,51 %"},{"name":"4 kHz to 5 kHz","range":"20 µF to 50 µF","cmc":"0,59 %"},{"name":"5 kHz to 6 kHz","range":"20 µF to 50 µF","cmc":"0,68 %"},{"name":"6 kHz to 7 kHz","range":"20 µF to 50 µF","cmc":"0,77 %"},{"name":"7 kHz to 8 kHz","range":"20 µF to 50 µF","cmc":"0,85 %"},{"name":"8 kHz to 9 kHz","range":"20 µF to 50 µF","cmc":"0,94 %"},{"name":"9 kHz to 10 kHz","range":"20 µF to 50 µF","cmc":"1,1 %"},{"name":"10 kHz to 15 kHz","range":"20 µF to 50 µF","cmc":"1,5 %"},{"name":"15 kHz to 20 kHz","range":"20 µF to 50 µF","cmc":"1,9 %"},{"name":"20 kHz to 25 kHz","range":"20 µF to 50 µF","cmc":"2,4 %"},{"name":"25 kHz to 30 kHz","range":"20 µF to 50 µF","cmc":"2,8 %"},{"name":"30 kHz to 40 kHz","range":"20 µF to 50 µF","cmc":"1,9 %"},{"name":"40 kHz to 50 kHz","range":"20 µF to 50 µF","cmc":"2,4 %"},{"name":"20 Hz to 50 Hz","range":"50 µF to 100 µF","cmc":"0,34 %"},{"name":"50 Hz to 500 Hz","range":"50 µF to 100 µF","cmc":"0,20 %"},{"name":"500 Hz to 700 Hz","range":"50 µF to 100 µF","cmc":"0,22 %"},{"name":"700 Hz to 1 kHz","range":"50 µF to 100 µF","cmc":"0,25 %"},{"name":"1 kHz to 2 kHz","range":"50 µF to 100 µF","cmc":"0,33 %"},{"name":"2 kHz to 3 kHz","range":"50 µF to 100 µF","cmc":"0,42 %"},{"name":"3 kHz to 4 kHz","range":"50 µF to 100 µF","cmc":"0,51 %"},{"name":"4 kHz to 5 kHz","range":"50 µF to 100 µF","cmc":"0,59 %"},{"name":"5 kHz to 6 kHz","range":"50 µF to 100 µF","cmc":"0,68 %"},{"name":"6 kHz to 7 kHz","range":"50 µF to 100 µF","cmc":"0,77 %"},{"name":"7 kHz to 8 kHz","range":"50 µF to 100 µF","cmc":"0,85 %"},{"name":"8 kHz to 9 kHz","range":"50 µF to 100 µF","cmc":"0,94 %"},{"name":"9 kHz to 10 kHz","range":"50 µF to 100 µF","cmc":"1,1 %"},{"name":"10 kHz to 15 kHz","range":"50 µF to 100 µF","cmc":"1,5 %"},{"name":"15 kHz to 20 kHz","range":"50 µF to 100 µF","cmc":"1,9 %"},{"name":"20 Hz to 50 Hz","range":"100 µF to 500 µF","cmc":"0,44 %"},{"name":"50 Hz to 70 Hz","range":"100 µF to 500 µF","cmc":"0,29 %"},{"name":"70 Hz to 200 Hz","range":"100 µF to 500 µF","cmc":"0,33 %"},{"name":"200 Hz to 300 Hz","range":"100 µF to 500 µF","cmc":"0,42 %"},{"name":"300 Hz to 400 Hz","range":"100 µF to 500 µF","cmc":"0,51 %"},{"name":"400 Hz to 500 Hz","range":"100 µF to 500 µF","cmc":"0,59 %"},{"name":"500 Hz to 600 Hz","range":"100 µF to 500 µF","cmc":"0,68 %"},{"name":"600 Hz to 700 Hz","range":"100 µF to 500 µF","cmc":"0,77 %"},{"name":"700 Hz to 800 Hz","range":"100 µF to 500 µF","cmc":"0,85 %"},{"name":"800 Hz to 900 Hz","range":"100 µF to 500 µF","cmc":"0,94 %"},{"name":"900 Hz to 2 kHz","range":"100 µF to 500 µF","cmc":"1,1 %"},{"name":"2 kHz to 3 kHz","range":"100 µF to 500 µF","cmc":"1,5 %"},{"name":"3 kHz to 4 kHz","range":"100 µF to 500 µF","cmc":"1,9 %"},{"name":"4 kHz to 5 kHz","range":"100 µF to 500 µF","cmc":"2,4 %"},{"name":"20 Hz to 50 Hz","range":"500 µF to 1 mF","cmc":"0,44 %"},{"name":"50 Hz to 70 Hz","range":"500 µF to 1 mF","cmc":"0,29 %"},{"name":"70 Hz to 200 Hz","range":"500 µF to 1 mF","cmc":"0,33 %"},{"name":"200 Hz to 300 Hz","range":"500 µF to 1 mF","cmc":"0,42 %"},{"name":"300 Hz to 400 Hz","range":"500 µF to 1 mF","cmc":"0,51 %"},{"name":"400 Hz to 500 Hz","range":"500 µF to 1 mF","cmc":"0,59 %"},{"name":"500 Hz to 600 Hz","range":"500 µF to 1 mF","cmc":"0,68 %"},{"name":"600 Hz to 700 Hz","range":"500 µF to 1 mF","cmc":"0,77 %"},{"name":"700 Hz to 800 Hz","range":"500 µF to 1 mF","cmc":"0,85 %"},{"name":"800 Hz to 900 Hz","range":"500 µF to 1 mF","cmc":"0,94 %"},{"name":"900 Hz to 1 kHz","range":"500 µF to 1 mF","cmc":"1,1 %"},{"name":"1 kHz to 2 kHz","range":"500 µF to 1 mF","cmc":"1,9 %"},{"name":"20 Hz to 30 Hz","range":"1 mF to 5 mF","cmc":"0,70 %"},{"name":"30 Hz to 40 Hz","range":"1 mF to 5 mF","cmc":"0,78 %"},{"name":"40 Hz to 80 Hz","range":"1 mF to 5 mF","cmc":"0,89 %"},{"name":"80 Hz to 90 Hz","range":"1 mF to 5 mF","cmc":"0,96 %"},{"name":"90 Hz to 160 Hz","range":"1 mF to 5 mF","cmc":"1,1 %"},{"name":"160 Hz to 300 Hz","range":"1 mF to 5 mF","cmc":"1,7 %"},{"name":"300 Hz to 400 Hz","range":"1 mF to 5 mF","cmc":"2,1 %"},{"name":"400 Hz to 500 Hz","range":"1 mF to 5 mF","cmc":"2,6 %"},{"name":"500 Hz to 600 Hz","range":"1 mF to 5 mF","cmc":"3,0 %"},{"name":"600 Hz to 700 Hz","range":"1 mF to 5 mF","cmc":"3,4 %"},{"name":"700 Hz to 800 Hz","range":"1 mF to 5 mF","cmc":"3,9 %"},{"name":"800 Hz to 900 Hz","range":"1 mF to 5 mF","cmc":"4,3 %"},{"name":"900 Hz to 1 kHz","range":"1 mF to 5 mF","cmc":"4,7 %"},{"name":"50 Hz to 60 Hz","range":"5 mF to 10 mF","cmc":"1,4 %"},{"name":"60 Hz to 160 Hz","range":"5 mF to 10 mF","cmc":"1,9 %"},{"name":"160 Hz to 220 Hz","range":"5 mF to 10 mF","cmc":"2,3 %"},{"name":"220 Hz to 300 Hz","range":"5 mF to 10 mF","cmc":"3,0 %"}],"parameters_zh":[{"name":"10 kHz 至 15 kHz","range":"1 pF 至 5 pF","cmc":"2,2 %"},{"name":"15 kHz 至 20 kHz","range":"1 pF 至 5 pF","cmc":"1,5 %"},{"name":"20 kHz 至 25 kHz","range":"1 pF 至 5 pF","cmc":"1,2 %"},{"name":"25 kHz 至 30 kHz","range":"1 pF 至 5 pF","cmc":"0,94 %"},{"name":"30 kHz 至 40 kHz","range":"1 pF 至 5 pF","cmc":"0,81 %"},{"name":"40 kHz 至 50 kHz","range":"1 pF 至 5 pF","cmc":"0,65 %"},{"name":"50 kHz 至 60 kHz","range":"1 pF 至 5 pF","cmc":"0,55 %"},{"name":"60 kHz 至 70 kHz","range":"1 pF 至 5 pF","cmc":"0,49 %"},{"name":"70 kHz 至 80 kHz","range":"1 pF 至 5 pF","cmc":"0,44 %"},{"name":"80 kHz 至 100 kHz","range":"1 pF 至 5 pF","cmc":"0,40 %"},{"name":"100 kHz 至 110 kHz","range":"1 pF 至 5 pF","cmc":"0,75 %"},{"name":"110 kHz 至 120 kHz","range":"1 pF 至 5 pF","cmc":"0,69 %"},{"name":"120 kHz 至 130 kHz","range":"1 pF 至 5 pF","cmc":"0,65 %"},{"name":"130 kHz 至 140 kHz","range":"1 pF 至 5 pF","cmc":"0,61 %"},{"name":"140 kHz 至 150 kHz","range":"1 pF 至 5 pF","cmc":"0,58 %"},{"name":"150 kHz 至 170 kHz","range":"1 pF 至 5 pF","cmc":"0,55 %"},{"name":"170 kHz 至 200 kHz","range":"1 pF 至 5 pF","cmc":"0,50 %"},{"name":"200 kHz 至 250 kHz","range":"1 pF 至 5 pF","cmc":"0,45 %"},{"name":"250 kHz 至 300 kHz","range":"1 pF 至 5 pF","cmc":"0,39 %"},{"name":"300 kHz 至 350 kHz","range":"1 pF 至 5 pF","cmc":"0,81 %"},{"name":"350 kHz 至 400 kHz","range":"1 pF 至 5 pF","cmc":"0,72 %"},{"name":"400 kHz 至 450 kHz","range":"1 pF 至 5 pF","cmc":"0,65 %"},{"name":"450 kHz 至 500 kHz","range":"1 pF 至 5 pF","cmc":"0,59 %"},{"name":"500 kHz 至 600 kHz","range":"1 pF 至 5 pF","cmc":"0,55 %"},{"name":"600 kHz 至 700 kHz","range":"1 pF 至 5 pF","cmc":"0,49 %"},{"name":"700 kHz 至 800 kHz","range":"1 pF 至 5 pF","cmc":"0,44 %"},{"name":"800 kHz 至 1 MHz","range":"1 pF 至 5 pF","cmc":"0,40 %"},{"name":"1 kHz 至 2 kHz","range":"5 pF 至 10 pF","cmc":"4,1 %"},{"name":"2 kHz 至 3 kHz","range":"5 pF 至 10 pF","cmc":"2,2 %"},{"name":"3 kHz 至 4 kHz","range":"5 pF 至 10 pF","cmc":"1,5 %"},{"name":"4 kHz 至 5 kHz","range":"5 pF 至 10 pF","cmc":"1,2 %"},{"name":"5 kHz 至 6 kHz","range":"5 pF 至 10 pF","cmc":"0,94 %"},{"name":"6 kHz 至 7 kHz","range":"5 pF 至 10 pF","cmc":"0,81 %"},{"name":"7 kHz 至 8 kHz","range":"5 pF 至 10 pF","cmc":"0,72 %"},{"name":"8 kHz 至 9 kHz","range":"5 pF 至 10 pF","cmc":"0,65 %"},{"name":"9 kHz 至 10 kHz","range":"5 pF 至 10 pF","cmc":"0,59 %"},{"name":"10 kHz 至 15 kHz","range":"5 pF 至 10 pF","cmc":"0,55 %"},{"name":"15 kHz 至 20 kHz","range":"5 pF 至 10 pF","cmc":"0,42 %"},{"name":"20 kHz 至 25 kHz","range":"5 pF 至 10 pF","cmc":"0,36 %"},{"name":"25 kHz 至 30 kHz","range":"5 pF 至 10 pF","cmc":"0,32 %"},{"name":"30 kHz 至 1 MHz","range":"5 pF 至 10 pF","cmc":"0,29 %"},{"name":"500 Hz 至 600 Hz","range":"10 pF 至 50 pF","cmc":"4,3 %"},{"name":"600 Hz 至 700 Hz","range":"10 pF 至 50 pF","cmc":"3,7 %"},{"name":"700 Hz 至 800 Hz","range":"10 pF 至 50 pF","cmc":"3,2 %"},{"name":"800 Hz 至 900 Hz","range":"10 pF 至 50 pF","cmc":"2,8 %"},{"name":"900 Hz 至 1 kHz","range":"10 pF 至 50 pF","cmc":"2,6 %"},{"name":"1 kHz 至 2 kHz","range":"10 pF 至 50 pF","cmc":"2,2 %"},{"name":"2 kHz 至 3 kHz","range":"10 pF 至 50 pF","cmc":"1,2 %"},{"name":"3 kHz 至 4 kHz","range":"10 pF 至 50 pF","cmc":"0,81 %"},{"name":"4 kHz 至 5 kHz","range":"10 pF 至 50 pF","cmc":"0,65 %"},{"name":"5 kHz 至 6 kHz","range":"10 pF 至 50 pF","cmc":"0,55 %"},{"name":"6 kHz 至 7 kHz","range":"10 pF 至 50 pF","cmc":"0,49 %"},{"name":"7 kHz 至 8 kHz","range":"10 pF 至 50 pF","cmc":"0,44 %"},{"name":"8 kHz 至 9 kHz","range":"10 pF 至 50 pF","cmc":"0,40 %"},{"name":"9 kHz 至 10 kHz","range":"10 pF 至 50 pF","cmc":"0,38 %"},{"name":"10 kHz 至 15 kHz","range":"10 pF 至 50 pF","cmc":"0,36 %"},{"name":"15 kHz 至 20 kHz","range":"10 pF 至 50 pF","cmc":"0,29 %"},{"name":"20 kHz 至 1 MHz","range":"10 pF 至 50 pF","cmc":"0,26 %"},{"name":"100 Hz 至 200 Hz","range":"50 pF 至 100 pF","cmc":"4,3 %"},{"name":"200 Hz 至 300 Hz","range":"50 pF 至 100 pF","cmc":"2,3 %"},{"name":"300 Hz 至 400 Hz","range":"50 pF 至 100 pF","cmc":"1,7 %"},{"name":"400 Hz 至 500 Hz","range":"50 pF 至 100 pF","cmc":"1,4 %"},{"name":"500 Hz 至 600 Hz","range":"50 pF 至 100 pF","cmc":"1,2 %"},{"name":"600 Hz 至 700 Hz","range":"50 pF 至 100 pF","cmc":"0,99 %"},{"name":"700 Hz 至 800 Hz","range":"50 pF 至 100 pF","cmc":"0,89 %"},{"name":"800 Hz 至 900 Hz","range":"50 pF 至 100 pF","cmc":"0,82 %"},{"name":"900 Hz 至 1 kHz","range":"50 pF 至 100 pF","cmc":"0,77 %"},{"name":"1 kHz 至 2 kHz","range":"50 pF 至 100 pF","cmc":"0,55 %"},{"name":"2 kHz 至 3 kHz","range":"50 pF 至 100 pF","cmc":"0,36 %"},{"name":"3 kHz 至 4 kHz","range":"50 pF 至 100 pF","cmc":"0,29 %"},{"name":"4 kHz 至 5 kHz","range":"50 pF 至 100 pF","cmc":"0,26 %"},{"name":"5 kHz 至 1 MHz","range":"50 pF 至 100 pF","cmc":"0,24 %"},{"name":"50 Hz 至 60 Hz","range":"100 pF 至 500 pF","cmc":"9,9 %"},{"name":"60 Hz 至 70 Hz","range":"100 pF 至 500 pF","cmc":"7,9 %"},{"name":"70 Hz 至 80 Hz","range":"100 pF 至 500 pF","cmc":"6,5 %"},{"name":"80 Hz 至 90 Hz","range":"100 pF 至 500 pF","cmc":"5,6 %"},{"name":"90 Hz 至 100 Hz","range":"100 pF 至 500 pF","cmc":"4,9 %"},{"name":"100 Hz 至 160 Hz","range":"100 pF 至 500 pF","cmc":"2,3 %"},{"name":"160 Hz 至 200 Hz","range":"100 pF 至 500 pF","cmc":"1,4 %"},{"name":"200 Hz 至 300 Hz","range":"100 pF 至 500 pF","cmc":"1,2 %"},{"name":"300 Hz 至 400 Hz","range":"100 pF 至 500 pF","cmc":"0,81 %"},{"name":"400 Hz 至 500 Hz","range":"100 pF 至 500 pF","cmc":"0,65 %"},{"name":"500 Hz 至 600 Hz","range":"100 pF 至 500 pF","cmc":"0,55 %"},{"name":"600 Hz 至 700 Hz","range":"100 pF 至 500 pF","cmc":"0,49 %"},{"name":"700 Hz 至 800 Hz","range":"100 pF 至 500 pF","cmc":"0,44 %"},{"name":"800 Hz 至 900 Hz","range":"100 pF 至 500 pF","cmc":"0,40 %"},{"name":"900 Hz 至 1 kHz","range":"100 pF 至 500 pF","cmc":"0,38 %"},{"name":"1 kHz 至 2 kHz","range":"100 pF 至 500 pF","cmc":"0,36 %"},{"name":"2 kHz 至 3 kHz","range":"100 pF 至 500 pF","cmc":"0,26 %"},{"name":"3 kHz 至 4 kHz","range":"100 pF 至 500 pF","cmc":"0,23 %"},{"name":"4 kHz 至 5 kHz","range":"100 pF 至 500 pF","cmc":"0,21 %"},{"name":"5 kHz 至 1 MHz","range":"100 pF 至 500 pF","cmc":"0,17 %"},{"name":"50 Hz 至 60 Hz","range":"500 pF 至 1 nF","cmc":"2,3 %"},{"name":"60 Hz 至 70 Hz","range":"500 pF 至 1 nF","cmc":"1,9 %"},{"name":"70 Hz 至 80 Hz","range":"500 pF 至 1 nF","cmc":"1,6 %"},{"name":"80 Hz 至 100 Hz","range":"500 pF 至 1 nF","cmc":"1,4 %"},{"name":"100 Hz 至 160 Hz","range":"500 pF 至 1 nF","cmc":"0,72 %"},{"name":"160 Hz 至 200 Hz","range":"500 pF 至 1 nF","cmc":"0,40 %"},{"name":"200 Hz 至 300 Hz","range":"500 pF 至 1 nF","cmc":"0,36 %"},{"name":"300 Hz 至 400 Hz","range":"500 pF 至 1 nF","cmc":"0,29 %"},{"name":"400 Hz 至 500 Hz","range":"500 pF 至 1 nF","cmc":"0,26 %"},{"name":"500 Hz 至 700 Hz","range":"500 pF 至 1 nF","cmc":"0,24 %"},{"name":"700 Hz 至 1 kHz","range":"500 pF 至 1 nF","cmc":"0,22 %"},{"name":"1 kHz 至 2 kHz","range":"500 pF 至 1 nF","cmc":"0,36 %"},{"name":"2 kHz 至 3 kHz","range":"500 pF 至 1 nF","cmc":"0,26 %"},{"name":"3 kHz 至 4 kHz","range":"500 pF 至 1 nF","cmc":"0,23 %"},{"name":"4 kHz 至 5 kHz","range":"500 pF 至 1 nF","cmc":"0,21 %"},{"name":"5 kHz 至 1 MHz","range":"500 pF 至 1 nF","cmc":"0,17 %"},{"name":"20 Hz 至 30 Hz","range":"1 nF 至 5 nF","cmc":"3,6 %"},{"name":"30 Hz 至 40 Hz","range":"1 nF 至 5 nF","cmc":"2,2 %"},{"name":"40 Hz 至 50 Hz","range":"1 nF 至 5 nF","cmc":"1,6 %"},{"name":"50 Hz 至 60 Hz","range":"1 nF 至 5 nF","cmc":"1,2 %"},{"name":"60 Hz 至 70 Hz","range":"1 nF 至 5 nF","cmc":"0,91 %"},{"name":"70 Hz 至 80 Hz","range":"1 nF 至 5 nF","cmc":"0,77 %"},{"name":"80 Hz 至 90 Hz","range":"1 nF 至 5 nF","cmc":"0,68 %"},{"name":"90 Hz 至 100 Hz","range":"1 nF 至 5 nF","cmc":"0,61 %"},{"name":"100 Hz 至 200 Hz","range":"1 nF 至 5 nF","cmc":"0,36 %"},{"name":"200 Hz 至 300 Hz","range":"1 nF 至 5 nF","cmc":"0,26 %"},{"name":"300 Hz 至 500 Hz","range":"1 nF 至 5 nF","cmc":"0,23 %"},{"name":"500 Hz 至 1 MHz","range":"1 nF 至 5 nF","cmc":"0,15 %"},{"name":"20 Hz 至 30 Hz","range":"5 nF 至 10 nF","cmc":"0,97 %"},{"name":"30 Hz 至 40 Hz","range":"5 nF 至 10 nF","cmc":"0,70 %"},{"name":"40 Hz 至 50 Hz","range":"5 nF 至 10 nF","cmc":"0,58 %"},{"name":"50 Hz 至 60 Hz","range":"5 nF 至 10 nF","cmc":"0,35 %"},{"name":"60 Hz 至 70 Hz","range":"5 nF 至 10 nF","cmc":"0,31 %"},{"name":"70 Hz 至 100 Hz","range":"5 nF 至 10 nF","cmc":"0,28 %"},{"name":"100 Hz 至 400 Hz","range":"5 nF 至 10 nF","cmc":"0,20 %"},{"name":"400 Hz 至 500 Hz","range":"5 nF 至 10 nF","cmc":"0,17 %"},{"name":"500 Hz 至 1 MHz","range":"5 nF 至 10 nF","cmc":"0,13 %"},{"name":"20 Hz 至 30 Hz","range":"10 nF 至 50 nF","cmc":"0,65 %"},{"name":"30 Hz 至 40 Hz","range":"10 nF 至 50 nF","cmc":"0,52 %"},{"name":"40 Hz 至 50 Hz","range":"10 nF 至 50 nF","cmc":"0,46 %"},{"name":"50 Hz 至 70 Hz","range":"10 nF 至 50 nF","cmc":"0,26 %"},{"name":"70 Hz 至 100 Hz","range":"10 nF 至 50 nF","cmc":"0,22 %"},{"name":"100 Hz 至 103 kHz","range":"10 nF 至 50 nF","cmc":"0,13 %"},{"name":"103 kHz 至 150 kHz","range":"10 nF 至 50 nF","cmc":"0,19 %"},{"name":"150 kHz 至 300 kHz","range":"10 nF 至 50 nF","cmc":"0,21 %"},{"name":"300 kHz 至 500 kHz","range":"10 nF 至 50 nF","cmc":"0,28 %"},{"name":"500 kHz 至 1 MHz","range":"10 nF 至 50 nF","cmc":"0,39 %"},{"name":"20 Hz 至 40 Hz","range":"50 nF 至 100 nF","cmc":"0,40 %"},{"name":"40 Hz 至 50 Hz","range":"50 nF 至 100 nF","cmc":"0,36 %"},{"name":"50 Hz 至 70 Hz","range":"50 nF 至 100 nF","cmc":"0,26 %"},{"name":"70 Hz 至 100 Hz","range":"50 nF 至 100 nF","cmc":"0,22 %"},{"name":"100 Hz 至 103 kHz","range":"50 nF 至 100 nF","cmc":"0,13 %"},{"name":"103 kHz 至 150 kHz","range":"50 nF 至 100 nF","cmc":"0,19 %"},{"name":"150 kHz 至 300 kHz","range":"50 nF 至 100 nF","cmc":"0,21 %"},{"name":"300 kHz 至 500 kHz","range":"50 nF 至 100 nF","cmc":"0,28 %"},{"name":"500 kHz 至 1 MHz","range":"50 nF 至 100 nF","cmc":"0,39 %"},{"name":"20 Hz 至 50 Hz","range":"100 nF 至 500 nF","cmc":"0,36 %"},{"name":"50 Hz 至 100 Hz","range":"100 nF 至 500 nF","cmc":"0,18 %"},{"name":"100 Hz 至 10 kHz","range":"100 nF 至 500 nF","cmc":"0,12 %"},{"name":"10 kHz 至 70 kHz","range":"100 nF 至 500 nF","cmc":"0,22 %"},{"name":"70 kHz 至 100 kHz","range":"100 nF 至 500 nF","cmc":"0,25 %"},{"name":"100 kHz 至 140 kHz","range":"100 nF 至 500 nF","cmc":"0,27 %"},{"name":"140 kHz 至 230 kHz","range":"100 nF 至 500 nF","cmc":"0,34 %"},{"name":"230 kHz 至 280 kHz","range":"100 nF 至 500 nF","cmc":"0,38 %"},{"name":"280 kHz 至 300 kHz","range":"100 nF 至 500 nF","cmc":"0,40 %"},{"name":"300 kHz 至 350 kHz","range":"100 nF 至 500 nF","cmc":"0,56 %"},{"name":"350 kHz 至 400 kHz","range":"100 nF 至 500 nF","cmc":"0,62 %"},{"name":"400 kHz 至 450 kHz","range":"100 nF 至 500 nF","cmc":"0,68 %"},{"name":"450 kHz 至 500 kHz","range":"100 nF 至 500 nF","cmc":"0,74 %"},{"name":"500 kHz 至 600 kHz","range":"100 nF 至 500 nF","cmc":"0,86 %"},{"name":"600 kHz 至 700 kHz","range":"100 nF 至 500 nF","cmc":"0,97 %"},{"name":"700 kHz 至 800 kHz","range":"100 nF 至 500 nF","cmc":"1,1 %"},{"name":"800 kHz 至 1 MHz","range":"100 nF 至 500 nF","cmc":"1,4 %"},{"name":"20 Hz 至 50 Hz","range":"500 nF 至 1 µF","cmc":"0,36 %"},{"name":"50 Hz 至 100 Hz","range":"500 nF 至 1 µF","cmc":"0,18 %"},{"name":"100 Hz 至 10 kHz","range":"500 nF 至 1 µF","cmc":"0,12 %"},{"name":"10 kHz 至 70 kHz","range":"500 nF 至 1 µF","cmc":"0,22 %"},{"name":"70 kHz 至 100 kHz","range":"500 nF 至 1 µF","cmc":"0,25 %"},{"name":"100 kHz 至 120 kHz","range":"500 nF 至 1 µF","cmc":"0,35 %"},{"name":"120 kHz 至 150 kHz","range":"500 nF 至 1 µF","cmc":"0,40 %"},{"name":"150 kHz 至 180 kHz","range":"500 nF 至 1 µF","cmc":"0,45 %"},{"name":"180 kHz 至 220 kHz","range":"500 nF 至 1 µF","cmc":"0,51 %"},{"name":"220 kHz 至 250 kHz","range":"500 nF 至 1 µF","cmc":"0,56 %"},{"name":"250 kHz 至 300 kHz","range":"500 nF 至 1 µF","cmc":"0,64 %"},{"name":"300 kHz 至 350 kHz","range":"500 nF 至 1 µF","cmc":"0,97 %"},{"name":"350 kHz 至 400 kHz","range":"500 nF 至 1 µF","cmc":"1,1 %"},{"name":"400 kHz 至 500 kHz","range":"500 nF 至 1 µF","cmc":"1,4 %"},{"name":"500 kHz 至 600 kHz","range":"500 nF 至 1 µF","cmc":"1,6 %"},{"name":"600 kHz 至 700 kHz","range":"500 nF 至 1 µF","cmc":"1,8 %"},{"name":"700 kHz 至 1 MHz","range":"500 nF 至 1 µF","cmc":"2,5 %"},{"name":"20 Hz 至 50 Hz","range":"1 µF 至 5 µF","cmc":"0,34 %"},{"name":"50 Hz 至 5 kHz","range":"1 µF 至 5 µF","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"1 µF 至 5 µF","cmc":"0,25 %"},{"name":"10 kHz 至 15 kHz","range":"1 µF 至 5 µF","cmc":"0,29 %"},{"name":"15 kHz 至 20 kHz","range":"1 µF 至 5 µF","cmc":"0,33 %"},{"name":"20 kHz 至 25 kHz","range":"1 µF 至 5 µF","cmc":"0,38 %"},{"name":"25 kHz 至 30 kHz","range":"1 µF 至 5 µF","cmc":"0,42 %"},{"name":"30 kHz 至 40 kHz","range":"1 µF 至 5 µF","cmc":"0,33 %"},{"name":"40 kHz 至 50 kHz","range":"1 µF 至 5 µF","cmc":"0,38 %"},{"name":"50 kHz 至 60 kHz","range":"1 µF 至 5 µF","cmc":"0,42 %"},{"name":"60 kHz 至 70 kHz","range":"1 µF 至 5 µF","cmc":"0,46 %"},{"name":"70 kHz 至 80 kHz","range":"1 µF 至 5 µF","cmc":"0,51 %"},{"name":"80 kHz 至 90 kHz","range":"1 µF 至 5 µF","cmc":"0,55 %"},{"name":"90 kHz 至 100 kHz","range":"1 µF 至 5 µF","cmc":"0,59 %"},{"name":"100 kHz 至 110 kHz","range":"1 µF 至 5 µF","cmc":"1,1 %"},{"name":"110 kHz 至 140 kHz","range":"1 µF 至 5 µF","cmc":"1,3 %"},{"name":"140 kHz 至 160 kHz","range":"1 µF 至 5 µF","cmc":"1,5 %"},{"name":"160 kHz 至 190 kHz","range":"1 µF 至 5 µF","cmc":"1,7 %"},{"name":"190 kHz 至 210 kHz","range":"1 µF 至 5 µF","cmc":"1,9 %"},{"name":"210 kHz 至 250 kHz","range":"1 µF 至 5 µF","cmc":"2,2 %"},{"name":"250 kHz 至 300 kHz","range":"1 µF 至 5 µF","cmc":"2,6 %"},{"name":"300 kHz 至 350 kHz","range":"1 µF 至 5 µF","cmc":"4,3 %"},{"name":"350 kHz 至 400 kHz","range":"1 µF 至 5 µF","cmc":"4,9 %"},{"name":"400 kHz 至 450 kHz","range":"1 µF 至 5 µF","cmc":"5,4 %"},{"name":"450 kHz 至 500 kHz","range":"1 µF 至 5 µF","cmc":"6,0 %"},{"name":"20 Hz 至 50 Hz","range":"5 µF 至 10 µF","cmc":"0,34 %"},{"name":"50 Hz 至 5 kHz","range":"5 µF 至 10 µF","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"5 µF 至 10 µF","cmc":"0,25 %"},{"name":"10 kHz 至 15 kHz","range":"5 µF 至 10 µF","cmc":"0,29 %"},{"name":"15 kHz 至 20 kHz","range":"5 µF 至 10 µF","cmc":"0,33 %"},{"name":"20 kHz 至 25 kHz","range":"5 µF 至 10 µF","cmc":"0,38 %"},{"name":"25 kHz 至 30 kHz","range":"5 µF 至 10 µF","cmc":"0,42 %"},{"name":"30 kHz 至 40 kHz","range":"5 µF 至 10 µF","cmc":"0,51 %"},{"name":"40 kHz 至 50 kHz","range":"5 µF 至 10 µF","cmc":"0,59 %"},{"name":"50 kHz 至 60 kHz","range":"5 µF 至 10 µF","cmc":"0,68 %"},{"name":"60 kHz 至 70 kHz","range":"5 µF 至 10 µF","cmc":"0,77 %"},{"name":"70 kHz 至 80 kHz","range":"5 µF 至 10 µF","cmc":"0,85 %"},{"name":"80 kHz 至 90 kHz","range":"5 µF 至 10 µF","cmc":"0,94 %"},{"name":"90 kHz 至 100 kHz","range":"5 µF 至 10 µF","cmc":"1,1 %"},{"name":"100 kHz 至 110 kHz","range":"5 µF 至 10 µF","cmc":"2,0 %"},{"name":"110 kHz 至 140 kHz","range":"5 µF 至 10 µF","cmc":"2,4 %"},{"name":"140 kHz 至 160 kHz","range":"5 µF 至 10 µF","cmc":"2,8 %"},{"name":"160 kHz 至 190 kHz","range":"5 µF 至 10 µF","cmc":"3,2 %"},{"name":"190 kHz 至 210 kHz","range":"5 µF 至 10 µF","cmc":"3,6 %"},{"name":"210 kHz 至 250 kHz","range":"5 µF 至 10 µF","cmc":"4,2 %"},{"name":"250 kHz 至 300 kHz","range":"5 µF 至 10 µF","cmc":"5,0 %"},{"name":"20 Hz 至 50 Hz","range":"10 µF 至 20 µF","cmc":"0,34 %"},{"name":"50 Hz 至 500 Hz","range":"10 µF 至 20 µF","cmc":"0,20 %"},{"name":"500 Hz 至 700 Hz","range":"10 µF 至 20 µF","cmc":"0,22 %"},{"name":"700 Hz 至 1 kHz","range":"10 µF 至 20 µF","cmc":"0,25 %"},{"name":"1 kHz 至 2 kHz","range":"10 µF 至 20 µF","cmc":"0,33 %"},{"name":"2 kHz 至 3 kHz","range":"10 µF 至 20 µF","cmc":"0,42 %"},{"name":"3 kHz 至 4 kHz","range":"10 µF 至 20 µF","cmc":"0,51 %"},{"name":"4 kHz 至 5 kHz","range":"10 µF 至 20 µF","cmc":"0,59 %"},{"name":"5 kHz 至 6 kHz","range":"10 µF 至 20 µF","cmc":"0,68 %"},{"name":"6 kHz 至 7 kHz","range":"10 µF 至 20 µF","cmc":"0,77 %"},{"name":"7 kHz 至 8 kHz","range":"10 µF 至 20 µF","cmc":"0,85 %"},{"name":"8 kHz 至 9 kHz","range":"10 µF 至 20 µF","cmc":"0,94 %"},{"name":"9 kHz 至 10 kHz","range":"10 µF 至 20 µF","cmc":"1,1 %"},{"name":"10 kHz 至 15 kHz","range":"10 µF 至 20 µF","cmc":"1,5 %"},{"name":"15 kHz 至 20 kHz","range":"10 µF 至 20 µF","cmc":"1,9 %"},{"name":"20 kHz 至 25 kHz","range":"10 µF 至 20 µF","cmc":"2,4 %"},{"name":"25 kHz 至 30 kHz","range":"10 µF 至 20 µF","cmc":"2,8 %"},{"name":"30 kHz 至 40 kHz","range":"10 µF 至 20 µF","cmc":"1,9 %"},{"name":"40 kHz 至 50 kHz","range":"10 µF 至 20 µF","cmc":"2,4 %"},{"name":"50 kHz 至 60 kHz","range":"10 µF 至 20 µF","cmc":"2,8 %"},{"name":"60 kHz 至 70 kHz","range":"10 µF 至 20 µF","cmc":"3,2 %"},{"name":"70 kHz 至 80 kHz","range":"10 µF 至 20 µF","cmc":"3,7 %"},{"name":"80 kHz 至 90 kHz","range":"10 µF 至 20 µF","cmc":"4,1 %"},{"name":"90 kHz 至 100 kHz","range":"10 µF 至 20 µF","cmc":"4,6 %"},{"name":"20 Hz 至 50 Hz","range":"20 µF 至 50 µF","cmc":"0,34 %"},{"name":"50 Hz 至 500 Hz","range":"20 µF 至 50 µF","cmc":"0,20 %"},{"name":"500 Hz 至 700 Hz","range":"20 µF 至 50 µF","cmc":"0,22 %"},{"name":"700 Hz 至 1 kHz","range":"20 µF 至 50 µF","cmc":"0,25 %"},{"name":"1 kHz 至 2 kHz","range":"20 µF 至 50 µF","cmc":"0,33 %"},{"name":"2 kHz 至 3 kHz","range":"20 µF 至 50 µF","cmc":"0,42 %"},{"name":"3 kHz 至 4 kHz","range":"20 µF 至 50 µF","cmc":"0,51 %"},{"name":"4 kHz 至 5 kHz","range":"20 µF 至 50 µF","cmc":"0,59 %"},{"name":"5 kHz 至 6 kHz","range":"20 µF 至 50 µF","cmc":"0,68 %"},{"name":"6 kHz 至 7 kHz","range":"20 µF 至 50 µF","cmc":"0,77 %"},{"name":"7 kHz 至 8 kHz","range":"20 µF 至 50 µF","cmc":"0,85 %"},{"name":"8 kHz 至 9 kHz","range":"20 µF 至 50 µF","cmc":"0,94 %"},{"name":"9 kHz 至 10 kHz","range":"20 µF 至 50 µF","cmc":"1,1 %"},{"name":"10 kHz 至 15 kHz","range":"20 µF 至 50 µF","cmc":"1,5 %"},{"name":"15 kHz 至 20 kHz","range":"20 µF 至 50 µF","cmc":"1,9 %"},{"name":"20 kHz 至 25 kHz","range":"20 µF 至 50 µF","cmc":"2,4 %"},{"name":"25 kHz 至 30 kHz","range":"20 µF 至 50 µF","cmc":"2,8 %"},{"name":"30 kHz 至 40 kHz","range":"20 µF 至 50 µF","cmc":"1,9 %"},{"name":"40 kHz 至 50 kHz","range":"20 µF 至 50 µF","cmc":"2,4 %"},{"name":"20 Hz 至 50 Hz","range":"50 µF 至 100 µF","cmc":"0,34 %"},{"name":"50 Hz 至 500 Hz","range":"50 µF 至 100 µF","cmc":"0,20 %"},{"name":"500 Hz 至 700 Hz","range":"50 µF 至 100 µF","cmc":"0,22 %"},{"name":"700 Hz 至 1 kHz","range":"50 µF 至 100 µF","cmc":"0,25 %"},{"name":"1 kHz 至 2 kHz","range":"50 µF 至 100 µF","cmc":"0,33 %"},{"name":"2 kHz 至 3 kHz","range":"50 µF 至 100 µF","cmc":"0,42 %"},{"name":"3 kHz 至 4 kHz","range":"50 µF 至 100 µF","cmc":"0,51 %"},{"name":"4 kHz 至 5 kHz","range":"50 µF 至 100 µF","cmc":"0,59 %"},{"name":"5 kHz 至 6 kHz","range":"50 µF 至 100 µF","cmc":"0,68 %"},{"name":"6 kHz 至 7 kHz","range":"50 µF 至 100 µF","cmc":"0,77 %"},{"name":"7 kHz 至 8 kHz","range":"50 µF 至 100 µF","cmc":"0,85 %"},{"name":"8 kHz 至 9 kHz","range":"50 µF 至 100 µF","cmc":"0,94 %"},{"name":"9 kHz 至 10 kHz","range":"50 µF 至 100 µF","cmc":"1,1 %"},{"name":"10 kHz 至 15 kHz","range":"50 µF 至 100 µF","cmc":"1,5 %"},{"name":"15 kHz 至 20 kHz","range":"50 µF 至 100 µF","cmc":"1,9 %"},{"name":"20 Hz 至 50 Hz","range":"100 µF 至 500 µF","cmc":"0,44 %"},{"name":"50 Hz 至 70 Hz","range":"100 µF 至 500 µF","cmc":"0,29 %"},{"name":"70 Hz 至 200 Hz","range":"100 µF 至 500 µF","cmc":"0,33 %"},{"name":"200 Hz 至 300 Hz","range":"100 µF 至 500 µF","cmc":"0,42 %"},{"name":"300 Hz 至 400 Hz","range":"100 µF 至 500 µF","cmc":"0,51 %"},{"name":"400 Hz 至 500 Hz","range":"100 µF 至 500 µF","cmc":"0,59 %"},{"name":"500 Hz 至 600 Hz","range":"100 µF 至 500 µF","cmc":"0,68 %"},{"name":"600 Hz 至 700 Hz","range":"100 µF 至 500 µF","cmc":"0,77 %"},{"name":"700 Hz 至 800 Hz","range":"100 µF 至 500 µF","cmc":"0,85 %"},{"name":"800 Hz 至 900 Hz","range":"100 µF 至 500 µF","cmc":"0,94 %"},{"name":"900 Hz 至 2 kHz","range":"100 µF 至 500 µF","cmc":"1,1 %"},{"name":"2 kHz 至 3 kHz","range":"100 µF 至 500 µF","cmc":"1,5 %"},{"name":"3 kHz 至 4 kHz","range":"100 µF 至 500 µF","cmc":"1,9 %"},{"name":"4 kHz 至 5 kHz","range":"100 µF 至 500 µF","cmc":"2,4 %"},{"name":"20 Hz 至 50 Hz","range":"500 µF 至 1 mF","cmc":"0,44 %"},{"name":"50 Hz 至 70 Hz","range":"500 µF 至 1 mF","cmc":"0,29 %"},{"name":"70 Hz 至 200 Hz","range":"500 µF 至 1 mF","cmc":"0,33 %"},{"name":"200 Hz 至 300 Hz","range":"500 µF 至 1 mF","cmc":"0,42 %"},{"name":"300 Hz 至 400 Hz","range":"500 µF 至 1 mF","cmc":"0,51 %"},{"name":"400 Hz 至 500 Hz","range":"500 µF 至 1 mF","cmc":"0,59 %"},{"name":"500 Hz 至 600 Hz","range":"500 µF 至 1 mF","cmc":"0,68 %"},{"name":"600 Hz 至 700 Hz","range":"500 µF 至 1 mF","cmc":"0,77 %"},{"name":"700 Hz 至 800 Hz","range":"500 µF 至 1 mF","cmc":"0,85 %"},{"name":"800 Hz 至 900 Hz","range":"500 µF 至 1 mF","cmc":"0,94 %"},{"name":"900 Hz 至 1 kHz","range":"500 µF 至 1 mF","cmc":"1,1 %"},{"name":"1 kHz 至 2 kHz","range":"500 µF 至 1 mF","cmc":"1,9 %"},{"name":"20 Hz 至 30 Hz","range":"1 mF 至 5 mF","cmc":"0,70 %"},{"name":"30 Hz 至 40 Hz","range":"1 mF 至 5 mF","cmc":"0,78 %"},{"name":"40 Hz 至 80 Hz","range":"1 mF 至 5 mF","cmc":"0,89 %"},{"name":"80 Hz 至 90 Hz","range":"1 mF 至 5 mF","cmc":"0,96 %"},{"name":"90 Hz 至 160 Hz","range":"1 mF 至 5 mF","cmc":"1,1 %"},{"name":"160 Hz 至 300 Hz","range":"1 mF 至 5 mF","cmc":"1,7 %"},{"name":"300 Hz 至 400 Hz","range":"1 mF 至 5 mF","cmc":"2,1 %"},{"name":"400 Hz 至 500 Hz","range":"1 mF 至 5 mF","cmc":"2,6 %"},{"name":"500 Hz 至 600 Hz","range":"1 mF 至 5 mF","cmc":"3,0 %"},{"name":"600 Hz 至 700 Hz","range":"1 mF 至 5 mF","cmc":"3,4 %"},{"name":"700 Hz 至 800 Hz","range":"1 mF 至 5 mF","cmc":"3,9 %"},{"name":"800 Hz 至 900 Hz","range":"1 mF 至 5 mF","cmc":"4,3 %"},{"name":"900 Hz 至 1 kHz","range":"1 mF 至 5 mF","cmc":"4,7 %"},{"name":"50 Hz 至 60 Hz","range":"5 mF 至 10 mF","cmc":"1,4 %"},{"name":"60 Hz 至 160 Hz","range":"5 mF 至 10 mF","cmc":"1,9 %"},{"name":"160 Hz 至 220 Hz","range":"5 mF 至 10 mF","cmc":"2,3 %"},{"name":"220 Hz 至 300 Hz","range":"5 mF 至 10 mF","cmc":"3,0 %"}],"parameters_cs":[{"name":"10 kHz až 15 kHz","range":"1 pF až 5 pF","cmc":"2,2 %"},{"name":"15 kHz až 20 kHz","range":"1 pF až 5 pF","cmc":"1,5 %"},{"name":"20 kHz až 25 kHz","range":"1 pF až 5 pF","cmc":"1,2 %"},{"name":"25 kHz až 30 kHz","range":"1 pF až 5 pF","cmc":"0,94 %"},{"name":"30 kHz až 40 kHz","range":"1 pF až 5 pF","cmc":"0,81 %"},{"name":"40 kHz až 50 kHz","range":"1 pF až 5 pF","cmc":"0,65 %"},{"name":"50 kHz až 60 kHz","range":"1 pF až 5 pF","cmc":"0,55 %"},{"name":"60 kHz až 70 kHz","range":"1 pF až 5 pF","cmc":"0,49 %"},{"name":"70 kHz až 80 kHz","range":"1 pF až 5 pF","cmc":"0,44 %"},{"name":"80 kHz až 100 kHz","range":"1 pF až 5 pF","cmc":"0,40 %"},{"name":"100 kHz až 110 kHz","range":"1 pF až 5 pF","cmc":"0,75 %"},{"name":"110 kHz až 120 kHz","range":"1 pF až 5 pF","cmc":"0,69 %"},{"name":"120 kHz až 130 kHz","range":"1 pF až 5 pF","cmc":"0,65 %"},{"name":"130 kHz až 140 kHz","range":"1 pF až 5 pF","cmc":"0,61 %"},{"name":"140 kHz až 150 kHz","range":"1 pF až 5 pF","cmc":"0,58 %"},{"name":"150 kHz až 170 kHz","range":"1 pF až 5 pF","cmc":"0,55 %"},{"name":"170 kHz až 200 kHz","range":"1 pF až 5 pF","cmc":"0,50 %"},{"name":"200 kHz až 250 kHz","range":"1 pF až 5 pF","cmc":"0,45 %"},{"name":"250 kHz až 300 kHz","range":"1 pF až 5 pF","cmc":"0,39 %"},{"name":"300 kHz až 350 kHz","range":"1 pF až 5 pF","cmc":"0,81 %"},{"name":"350 kHz až 400 kHz","range":"1 pF až 5 pF","cmc":"0,72 %"},{"name":"400 kHz až 450 kHz","range":"1 pF až 5 pF","cmc":"0,65 %"},{"name":"450 kHz až 500 kHz","range":"1 pF až 5 pF","cmc":"0,59 %"},{"name":"500 kHz až 600 kHz","range":"1 pF až 5 pF","cmc":"0,55 %"},{"name":"600 kHz až 700 kHz","range":"1 pF až 5 pF","cmc":"0,49 %"},{"name":"700 kHz až 800 kHz","range":"1 pF až 5 pF","cmc":"0,44 %"},{"name":"800 kHz až 1 MHz","range":"1 pF až 5 pF","cmc":"0,40 %"},{"name":"1 kHz až 2 kHz","range":"5 pF až 10 pF","cmc":"4,1 %"},{"name":"2 kHz až 3 kHz","range":"5 pF až 10 pF","cmc":"2,2 %"},{"name":"3 kHz až 4 kHz","range":"5 pF až 10 pF","cmc":"1,5 %"},{"name":"4 kHz až 5 kHz","range":"5 pF až 10 pF","cmc":"1,2 %"},{"name":"5 kHz až 6 kHz","range":"5 pF až 10 pF","cmc":"0,94 %"},{"name":"6 kHz až 7 kHz","range":"5 pF až 10 pF","cmc":"0,81 %"},{"name":"7 kHz až 8 kHz","range":"5 pF až 10 pF","cmc":"0,72 %"},{"name":"8 kHz až 9 kHz","range":"5 pF až 10 pF","cmc":"0,65 %"},{"name":"9 kHz až 10 kHz","range":"5 pF až 10 pF","cmc":"0,59 %"},{"name":"10 kHz až 15 kHz","range":"5 pF až 10 pF","cmc":"0,55 %"},{"name":"15 kHz až 20 kHz","range":"5 pF až 10 pF","cmc":"0,42 %"},{"name":"20 kHz až 25 kHz","range":"5 pF až 10 pF","cmc":"0,36 %"},{"name":"25 kHz až 30 kHz","range":"5 pF až 10 pF","cmc":"0,32 %"},{"name":"30 kHz až 1 MHz","range":"5 pF až 10 pF","cmc":"0,29 %"},{"name":"500 Hz až 600 Hz","range":"10 pF až 50 pF","cmc":"4,3 %"},{"name":"600 Hz až 700 Hz","range":"10 pF až 50 pF","cmc":"3,7 %"},{"name":"700 Hz až 800 Hz","range":"10 pF až 50 pF","cmc":"3,2 %"},{"name":"800 Hz až 900 Hz","range":"10 pF až 50 pF","cmc":"2,8 %"},{"name":"900 Hz až 1 kHz","range":"10 pF až 50 pF","cmc":"2,6 %"},{"name":"1 kHz až 2 kHz","range":"10 pF až 50 pF","cmc":"2,2 %"},{"name":"2 kHz až 3 kHz","range":"10 pF až 50 pF","cmc":"1,2 %"},{"name":"3 kHz až 4 kHz","range":"10 pF až 50 pF","cmc":"0,81 %"},{"name":"4 kHz až 5 kHz","range":"10 pF až 50 pF","cmc":"0,65 %"},{"name":"5 kHz až 6 kHz","range":"10 pF až 50 pF","cmc":"0,55 %"},{"name":"6 kHz až 7 kHz","range":"10 pF až 50 pF","cmc":"0,49 %"},{"name":"7 kHz až 8 kHz","range":"10 pF až 50 pF","cmc":"0,44 %"},{"name":"8 kHz až 9 kHz","range":"10 pF až 50 pF","cmc":"0,40 %"},{"name":"9 kHz až 10 kHz","range":"10 pF až 50 pF","cmc":"0,38 %"},{"name":"10 kHz až 15 kHz","range":"10 pF až 50 pF","cmc":"0,36 %"},{"name":"15 kHz až 20 kHz","range":"10 pF až 50 pF","cmc":"0,29 %"},{"name":"20 kHz až 1 MHz","range":"10 pF až 50 pF","cmc":"0,26 %"},{"name":"100 Hz až 200 Hz","range":"50 pF až 100 pF","cmc":"4,3 %"},{"name":"200 Hz až 300 Hz","range":"50 pF až 100 pF","cmc":"2,3 %"},{"name":"300 Hz až 400 Hz","range":"50 pF až 100 pF","cmc":"1,7 %"},{"name":"400 Hz až 500 Hz","range":"50 pF až 100 pF","cmc":"1,4 %"},{"name":"500 Hz až 600 Hz","range":"50 pF až 100 pF","cmc":"1,2 %"},{"name":"600 Hz až 700 Hz","range":"50 pF až 100 pF","cmc":"0,99 %"},{"name":"700 Hz až 800 Hz","range":"50 pF až 100 pF","cmc":"0,89 %"},{"name":"800 Hz až 900 Hz","range":"50 pF až 100 pF","cmc":"0,82 %"},{"name":"900 Hz až 1 kHz","range":"50 pF až 100 pF","cmc":"0,77 %"},{"name":"1 kHz až 2 kHz","range":"50 pF až 100 pF","cmc":"0,55 %"},{"name":"2 kHz až 3 kHz","range":"50 pF až 100 pF","cmc":"0,36 %"},{"name":"3 kHz až 4 kHz","range":"50 pF až 100 pF","cmc":"0,29 %"},{"name":"4 kHz až 5 kHz","range":"50 pF až 100 pF","cmc":"0,26 %"},{"name":"5 kHz až 1 MHz","range":"50 pF až 100 pF","cmc":"0,24 %"},{"name":"50 Hz až 60 Hz","range":"100 pF až 500 pF","cmc":"9,9 %"},{"name":"60 Hz až 70 Hz","range":"100 pF až 500 pF","cmc":"7,9 %"},{"name":"70 Hz až 80 Hz","range":"100 pF až 500 pF","cmc":"6,5 %"},{"name":"80 Hz až 90 Hz","range":"100 pF až 500 pF","cmc":"5,6 %"},{"name":"90 Hz až 100 Hz","range":"100 pF až 500 pF","cmc":"4,9 %"},{"name":"100 Hz až 160 Hz","range":"100 pF až 500 pF","cmc":"2,3 %"},{"name":"160 Hz až 200 Hz","range":"100 pF až 500 pF","cmc":"1,4 %"},{"name":"200 Hz až 300 Hz","range":"100 pF až 500 pF","cmc":"1,2 %"},{"name":"300 Hz až 400 Hz","range":"100 pF až 500 pF","cmc":"0,81 %"},{"name":"400 Hz až 500 Hz","range":"100 pF až 500 pF","cmc":"0,65 %"},{"name":"500 Hz až 600 Hz","range":"100 pF až 500 pF","cmc":"0,55 %"},{"name":"600 Hz až 700 Hz","range":"100 pF až 500 pF","cmc":"0,49 %"},{"name":"700 Hz až 800 Hz","range":"100 pF až 500 pF","cmc":"0,44 %"},{"name":"800 Hz až 900 Hz","range":"100 pF až 500 pF","cmc":"0,40 %"},{"name":"900 Hz až 1 kHz","range":"100 pF až 500 pF","cmc":"0,38 %"},{"name":"1 kHz až 2 kHz","range":"100 pF až 500 pF","cmc":"0,36 %"},{"name":"2 kHz až 3 kHz","range":"100 pF až 500 pF","cmc":"0,26 %"},{"name":"3 kHz až 4 kHz","range":"100 pF až 500 pF","cmc":"0,23 %"},{"name":"4 kHz až 5 kHz","range":"100 pF až 500 pF","cmc":"0,21 %"},{"name":"5 kHz až 1 MHz","range":"100 pF až 500 pF","cmc":"0,17 %"},{"name":"50 Hz až 60 Hz","range":"500 pF až 1 nF","cmc":"2,3 %"},{"name":"60 Hz až 70 Hz","range":"500 pF až 1 nF","cmc":"1,9 %"},{"name":"70 Hz až 80 Hz","range":"500 pF až 1 nF","cmc":"1,6 %"},{"name":"80 Hz až 100 Hz","range":"500 pF až 1 nF","cmc":"1,4 %"},{"name":"100 Hz až 160 Hz","range":"500 pF až 1 nF","cmc":"0,72 %"},{"name":"160 Hz až 200 Hz","range":"500 pF až 1 nF","cmc":"0,40 %"},{"name":"200 Hz až 300 Hz","range":"500 pF až 1 nF","cmc":"0,36 %"},{"name":"300 Hz až 400 Hz","range":"500 pF až 1 nF","cmc":"0,29 %"},{"name":"400 Hz až 500 Hz","range":"500 pF až 1 nF","cmc":"0,26 %"},{"name":"500 Hz až 700 Hz","range":"500 pF až 1 nF","cmc":"0,24 %"},{"name":"700 Hz až 1 kHz","range":"500 pF až 1 nF","cmc":"0,22 %"},{"name":"1 kHz až 2 kHz","range":"500 pF až 1 nF","cmc":"0,36 %"},{"name":"2 kHz až 3 kHz","range":"500 pF až 1 nF","cmc":"0,26 %"},{"name":"3 kHz až 4 kHz","range":"500 pF až 1 nF","cmc":"0,23 %"},{"name":"4 kHz až 5 kHz","range":"500 pF až 1 nF","cmc":"0,21 %"},{"name":"5 kHz až 1 MHz","range":"500 pF až 1 nF","cmc":"0,17 %"},{"name":"20 Hz až 30 Hz","range":"1 nF až 5 nF","cmc":"3,6 %"},{"name":"30 Hz až 40 Hz","range":"1 nF až 5 nF","cmc":"2,2 %"},{"name":"40 Hz až 50 Hz","range":"1 nF až 5 nF","cmc":"1,6 %"},{"name":"50 Hz až 60 Hz","range":"1 nF až 5 nF","cmc":"1,2 %"},{"name":"60 Hz až 70 Hz","range":"1 nF až 5 nF","cmc":"0,91 %"},{"name":"70 Hz až 80 Hz","range":"1 nF až 5 nF","cmc":"0,77 %"},{"name":"80 Hz až 90 Hz","range":"1 nF až 5 nF","cmc":"0,68 %"},{"name":"90 Hz až 100 Hz","range":"1 nF až 5 nF","cmc":"0,61 %"},{"name":"100 Hz až 200 Hz","range":"1 nF až 5 nF","cmc":"0,36 %"},{"name":"200 Hz až 300 Hz","range":"1 nF až 5 nF","cmc":"0,26 %"},{"name":"300 Hz až 500 Hz","range":"1 nF až 5 nF","cmc":"0,23 %"},{"name":"500 Hz až 1 MHz","range":"1 nF až 5 nF","cmc":"0,15 %"},{"name":"20 Hz až 30 Hz","range":"5 nF až 10 nF","cmc":"0,97 %"},{"name":"30 Hz až 40 Hz","range":"5 nF až 10 nF","cmc":"0,70 %"},{"name":"40 Hz až 50 Hz","range":"5 nF až 10 nF","cmc":"0,58 %"},{"name":"50 Hz až 60 Hz","range":"5 nF až 10 nF","cmc":"0,35 %"},{"name":"60 Hz až 70 Hz","range":"5 nF až 10 nF","cmc":"0,31 %"},{"name":"70 Hz až 100 Hz","range":"5 nF až 10 nF","cmc":"0,28 %"},{"name":"100 Hz až 400 Hz","range":"5 nF až 10 nF","cmc":"0,20 %"},{"name":"400 Hz až 500 Hz","range":"5 nF až 10 nF","cmc":"0,17 %"},{"name":"500 Hz až 1 MHz","range":"5 nF až 10 nF","cmc":"0,13 %"},{"name":"20 Hz až 30 Hz","range":"10 nF až 50 nF","cmc":"0,65 %"},{"name":"30 Hz až 40 Hz","range":"10 nF až 50 nF","cmc":"0,52 %"},{"name":"40 Hz až 50 Hz","range":"10 nF až 50 nF","cmc":"0,46 %"},{"name":"50 Hz až 70 Hz","range":"10 nF až 50 nF","cmc":"0,26 %"},{"name":"70 Hz až 100 Hz","range":"10 nF až 50 nF","cmc":"0,22 %"},{"name":"100 Hz až 103 kHz","range":"10 nF až 50 nF","cmc":"0,13 %"},{"name":"103 kHz až 150 kHz","range":"10 nF až 50 nF","cmc":"0,19 %"},{"name":"150 kHz až 300 kHz","range":"10 nF až 50 nF","cmc":"0,21 %"},{"name":"300 kHz až 500 kHz","range":"10 nF až 50 nF","cmc":"0,28 %"},{"name":"500 kHz až 1 MHz","range":"10 nF až 50 nF","cmc":"0,39 %"},{"name":"20 Hz až 40 Hz","range":"50 nF až 100 nF","cmc":"0,40 %"},{"name":"40 Hz až 50 Hz","range":"50 nF až 100 nF","cmc":"0,36 %"},{"name":"50 Hz až 70 Hz","range":"50 nF až 100 nF","cmc":"0,26 %"},{"name":"70 Hz až 100 Hz","range":"50 nF až 100 nF","cmc":"0,22 %"},{"name":"100 Hz až 103 kHz","range":"50 nF až 100 nF","cmc":"0,13 %"},{"name":"103 kHz až 150 kHz","range":"50 nF až 100 nF","cmc":"0,19 %"},{"name":"150 kHz až 300 kHz","range":"50 nF až 100 nF","cmc":"0,21 %"},{"name":"300 kHz až 500 kHz","range":"50 nF až 100 nF","cmc":"0,28 %"},{"name":"500 kHz až 1 MHz","range":"50 nF až 100 nF","cmc":"0,39 %"},{"name":"20 Hz až 50 Hz","range":"100 nF až 500 nF","cmc":"0,36 %"},{"name":"50 Hz až 100 Hz","range":"100 nF až 500 nF","cmc":"0,18 %"},{"name":"100 Hz až 10 kHz","range":"100 nF až 500 nF","cmc":"0,12 %"},{"name":"10 kHz až 70 kHz","range":"100 nF až 500 nF","cmc":"0,22 %"},{"name":"70 kHz až 100 kHz","range":"100 nF až 500 nF","cmc":"0,25 %"},{"name":"100 kHz až 140 kHz","range":"100 nF až 500 nF","cmc":"0,27 %"},{"name":"140 kHz až 230 kHz","range":"100 nF až 500 nF","cmc":"0,34 %"},{"name":"230 kHz až 280 kHz","range":"100 nF až 500 nF","cmc":"0,38 %"},{"name":"280 kHz až 300 kHz","range":"100 nF až 500 nF","cmc":"0,40 %"},{"name":"300 kHz až 350 kHz","range":"100 nF až 500 nF","cmc":"0,56 %"},{"name":"350 kHz až 400 kHz","range":"100 nF až 500 nF","cmc":"0,62 %"},{"name":"400 kHz až 450 kHz","range":"100 nF až 500 nF","cmc":"0,68 %"},{"name":"450 kHz až 500 kHz","range":"100 nF až 500 nF","cmc":"0,74 %"},{"name":"500 kHz až 600 kHz","range":"100 nF až 500 nF","cmc":"0,86 %"},{"name":"600 kHz až 700 kHz","range":"100 nF až 500 nF","cmc":"0,97 %"},{"name":"700 kHz až 800 kHz","range":"100 nF až 500 nF","cmc":"1,1 %"},{"name":"800 kHz až 1 MHz","range":"100 nF až 500 nF","cmc":"1,4 %"},{"name":"20 Hz až 50 Hz","range":"500 nF až 1 µF","cmc":"0,36 %"},{"name":"50 Hz až 100 Hz","range":"500 nF až 1 µF","cmc":"0,18 %"},{"name":"100 Hz až 10 kHz","range":"500 nF až 1 µF","cmc":"0,12 %"},{"name":"10 kHz až 70 kHz","range":"500 nF až 1 µF","cmc":"0,22 %"},{"name":"70 kHz až 100 kHz","range":"500 nF až 1 µF","cmc":"0,25 %"},{"name":"100 kHz až 120 kHz","range":"500 nF až 1 µF","cmc":"0,35 %"},{"name":"120 kHz až 150 kHz","range":"500 nF až 1 µF","cmc":"0,40 %"},{"name":"150 kHz až 180 kHz","range":"500 nF až 1 µF","cmc":"0,45 %"},{"name":"180 kHz až 220 kHz","range":"500 nF až 1 µF","cmc":"0,51 %"},{"name":"220 kHz až 250 kHz","range":"500 nF až 1 µF","cmc":"0,56 %"},{"name":"250 kHz až 300 kHz","range":"500 nF až 1 µF","cmc":"0,64 %"},{"name":"300 kHz až 350 kHz","range":"500 nF až 1 µF","cmc":"0,97 %"},{"name":"350 kHz až 400 kHz","range":"500 nF až 1 µF","cmc":"1,1 %"},{"name":"400 kHz až 500 kHz","range":"500 nF až 1 µF","cmc":"1,4 %"},{"name":"500 kHz až 600 kHz","range":"500 nF až 1 µF","cmc":"1,6 %"},{"name":"600 kHz až 700 kHz","range":"500 nF až 1 µF","cmc":"1,8 %"},{"name":"700 kHz až 1 MHz","range":"500 nF až 1 µF","cmc":"2,5 %"},{"name":"20 Hz až 50 Hz","range":"1 µF až 5 µF","cmc":"0,34 %"},{"name":"50 Hz až 5 kHz","range":"1 µF až 5 µF","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"1 µF až 5 µF","cmc":"0,25 %"},{"name":"10 kHz až 15 kHz","range":"1 µF až 5 µF","cmc":"0,29 %"},{"name":"15 kHz až 20 kHz","range":"1 µF až 5 µF","cmc":"0,33 %"},{"name":"20 kHz až 25 kHz","range":"1 µF až 5 µF","cmc":"0,38 %"},{"name":"25 kHz až 30 kHz","range":"1 µF až 5 µF","cmc":"0,42 %"},{"name":"30 kHz až 40 kHz","range":"1 µF až 5 µF","cmc":"0,33 %"},{"name":"40 kHz až 50 kHz","range":"1 µF až 5 µF","cmc":"0,38 %"},{"name":"50 kHz až 60 kHz","range":"1 µF až 5 µF","cmc":"0,42 %"},{"name":"60 kHz až 70 kHz","range":"1 µF až 5 µF","cmc":"0,46 %"},{"name":"70 kHz až 80 kHz","range":"1 µF až 5 µF","cmc":"0,51 %"},{"name":"80 kHz až 90 kHz","range":"1 µF až 5 µF","cmc":"0,55 %"},{"name":"90 kHz až 100 kHz","range":"1 µF až 5 µF","cmc":"0,59 %"},{"name":"100 kHz až 110 kHz","range":"1 µF až 5 µF","cmc":"1,1 %"},{"name":"110 kHz až 140 kHz","range":"1 µF až 5 µF","cmc":"1,3 %"},{"name":"140 kHz až 160 kHz","range":"1 µF až 5 µF","cmc":"1,5 %"},{"name":"160 kHz až 190 kHz","range":"1 µF až 5 µF","cmc":"1,7 %"},{"name":"190 kHz až 210 kHz","range":"1 µF až 5 µF","cmc":"1,9 %"},{"name":"210 kHz až 250 kHz","range":"1 µF až 5 µF","cmc":"2,2 %"},{"name":"250 kHz až 300 kHz","range":"1 µF až 5 µF","cmc":"2,6 %"},{"name":"300 kHz až 350 kHz","range":"1 µF až 5 µF","cmc":"4,3 %"},{"name":"350 kHz až 400 kHz","range":"1 µF až 5 µF","cmc":"4,9 %"},{"name":"400 kHz až 450 kHz","range":"1 µF až 5 µF","cmc":"5,4 %"},{"name":"450 kHz až 500 kHz","range":"1 µF až 5 µF","cmc":"6,0 %"},{"name":"20 Hz až 50 Hz","range":"5 µF až 10 µF","cmc":"0,34 %"},{"name":"50 Hz až 5 kHz","range":"5 µF až 10 µF","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"5 µF až 10 µF","cmc":"0,25 %"},{"name":"10 kHz až 15 kHz","range":"5 µF až 10 µF","cmc":"0,29 %"},{"name":"15 kHz až 20 kHz","range":"5 µF až 10 µF","cmc":"0,33 %"},{"name":"20 kHz až 25 kHz","range":"5 µF až 10 µF","cmc":"0,38 %"},{"name":"25 kHz až 30 kHz","range":"5 µF až 10 µF","cmc":"0,42 %"},{"name":"30 kHz až 40 kHz","range":"5 µF až 10 µF","cmc":"0,51 %"},{"name":"40 kHz až 50 kHz","range":"5 µF až 10 µF","cmc":"0,59 %"},{"name":"50 kHz až 60 kHz","range":"5 µF až 10 µF","cmc":"0,68 %"},{"name":"60 kHz až 70 kHz","range":"5 µF až 10 µF","cmc":"0,77 %"},{"name":"70 kHz až 80 kHz","range":"5 µF až 10 µF","cmc":"0,85 %"},{"name":"80 kHz až 90 kHz","range":"5 µF až 10 µF","cmc":"0,94 %"},{"name":"90 kHz až 100 kHz","range":"5 µF až 10 µF","cmc":"1,1 %"},{"name":"100 kHz až 110 kHz","range":"5 µF až 10 µF","cmc":"2,0 %"},{"name":"110 kHz až 140 kHz","range":"5 µF až 10 µF","cmc":"2,4 %"},{"name":"140 kHz až 160 kHz","range":"5 µF až 10 µF","cmc":"2,8 %"},{"name":"160 kHz až 190 kHz","range":"5 µF až 10 µF","cmc":"3,2 %"},{"name":"190 kHz až 210 kHz","range":"5 µF až 10 µF","cmc":"3,6 %"},{"name":"210 kHz až 250 kHz","range":"5 µF až 10 µF","cmc":"4,2 %"},{"name":"250 kHz až 300 kHz","range":"5 µF až 10 µF","cmc":"5,0 %"},{"name":"20 Hz až 50 Hz","range":"10 µF až 20 µF","cmc":"0,34 %"},{"name":"50 Hz až 500 Hz","range":"10 µF až 20 µF","cmc":"0,20 %"},{"name":"500 Hz až 700 Hz","range":"10 µF až 20 µF","cmc":"0,22 %"},{"name":"700 Hz až 1 kHz","range":"10 µF až 20 µF","cmc":"0,25 %"},{"name":"1 kHz až 2 kHz","range":"10 µF až 20 µF","cmc":"0,33 %"},{"name":"2 kHz až 3 kHz","range":"10 µF až 20 µF","cmc":"0,42 %"},{"name":"3 kHz až 4 kHz","range":"10 µF až 20 µF","cmc":"0,51 %"},{"name":"4 kHz až 5 kHz","range":"10 µF až 20 µF","cmc":"0,59 %"},{"name":"5 kHz až 6 kHz","range":"10 µF až 20 µF","cmc":"0,68 %"},{"name":"6 kHz až 7 kHz","range":"10 µF až 20 µF","cmc":"0,77 %"},{"name":"7 kHz až 8 kHz","range":"10 µF až 20 µF","cmc":"0,85 %"},{"name":"8 kHz až 9 kHz","range":"10 µF až 20 µF","cmc":"0,94 %"},{"name":"9 kHz až 10 kHz","range":"10 µF až 20 µF","cmc":"1,1 %"},{"name":"10 kHz až 15 kHz","range":"10 µF až 20 µF","cmc":"1,5 %"},{"name":"15 kHz až 20 kHz","range":"10 µF až 20 µF","cmc":"1,9 %"},{"name":"20 kHz až 25 kHz","range":"10 µF až 20 µF","cmc":"2,4 %"},{"name":"25 kHz až 30 kHz","range":"10 µF až 20 µF","cmc":"2,8 %"},{"name":"30 kHz až 40 kHz","range":"10 µF až 20 µF","cmc":"1,9 %"},{"name":"40 kHz až 50 kHz","range":"10 µF až 20 µF","cmc":"2,4 %"},{"name":"50 kHz až 60 kHz","range":"10 µF až 20 µF","cmc":"2,8 %"},{"name":"60 kHz až 70 kHz","range":"10 µF až 20 µF","cmc":"3,2 %"},{"name":"70 kHz až 80 kHz","range":"10 µF až 20 µF","cmc":"3,7 %"},{"name":"80 kHz až 90 kHz","range":"10 µF až 20 µF","cmc":"4,1 %"},{"name":"90 kHz až 100 kHz","range":"10 µF až 20 µF","cmc":"4,6 %"},{"name":"20 Hz až 50 Hz","range":"20 µF až 50 µF","cmc":"0,34 %"},{"name":"50 Hz až 500 Hz","range":"20 µF až 50 µF","cmc":"0,20 %"},{"name":"500 Hz až 700 Hz","range":"20 µF až 50 µF","cmc":"0,22 %"},{"name":"700 Hz až 1 kHz","range":"20 µF až 50 µF","cmc":"0,25 %"},{"name":"1 kHz až 2 kHz","range":"20 µF až 50 µF","cmc":"0,33 %"},{"name":"2 kHz až 3 kHz","range":"20 µF až 50 µF","cmc":"0,42 %"},{"name":"3 kHz až 4 kHz","range":"20 µF až 50 µF","cmc":"0,51 %"},{"name":"4 kHz až 5 kHz","range":"20 µF až 50 µF","cmc":"0,59 %"},{"name":"5 kHz až 6 kHz","range":"20 µF až 50 µF","cmc":"0,68 %"},{"name":"6 kHz až 7 kHz","range":"20 µF až 50 µF","cmc":"0,77 %"},{"name":"7 kHz až 8 kHz","range":"20 µF až 50 µF","cmc":"0,85 %"},{"name":"8 kHz až 9 kHz","range":"20 µF až 50 µF","cmc":"0,94 %"},{"name":"9 kHz až 10 kHz","range":"20 µF až 50 µF","cmc":"1,1 %"},{"name":"10 kHz až 15 kHz","range":"20 µF až 50 µF","cmc":"1,5 %"},{"name":"15 kHz až 20 kHz","range":"20 µF až 50 µF","cmc":"1,9 %"},{"name":"20 kHz až 25 kHz","range":"20 µF až 50 µF","cmc":"2,4 %"},{"name":"25 kHz až 30 kHz","range":"20 µF až 50 µF","cmc":"2,8 %"},{"name":"30 kHz až 40 kHz","range":"20 µF až 50 µF","cmc":"1,9 %"},{"name":"40 kHz až 50 kHz","range":"20 µF až 50 µF","cmc":"2,4 %"},{"name":"20 Hz až 50 Hz","range":"50 µF až 100 µF","cmc":"0,34 %"},{"name":"50 Hz až 500 Hz","range":"50 µF až 100 µF","cmc":"0,20 %"},{"name":"500 Hz až 700 Hz","range":"50 µF až 100 µF","cmc":"0,22 %"},{"name":"700 Hz až 1 kHz","range":"50 µF až 100 µF","cmc":"0,25 %"},{"name":"1 kHz až 2 kHz","range":"50 µF až 100 µF","cmc":"0,33 %"},{"name":"2 kHz až 3 kHz","range":"50 µF až 100 µF","cmc":"0,42 %"},{"name":"3 kHz až 4 kHz","range":"50 µF až 100 µF","cmc":"0,51 %"},{"name":"4 kHz až 5 kHz","range":"50 µF až 100 µF","cmc":"0,59 %"},{"name":"5 kHz až 6 kHz","range":"50 µF až 100 µF","cmc":"0,68 %"},{"name":"6 kHz až 7 kHz","range":"50 µF až 100 µF","cmc":"0,77 %"},{"name":"7 kHz až 8 kHz","range":"50 µF až 100 µF","cmc":"0,85 %"},{"name":"8 kHz až 9 kHz","range":"50 µF až 100 µF","cmc":"0,94 %"},{"name":"9 kHz až 10 kHz","range":"50 µF až 100 µF","cmc":"1,1 %"},{"name":"10 kHz až 15 kHz","range":"50 µF až 100 µF","cmc":"1,5 %"},{"name":"15 kHz až 20 kHz","range":"50 µF až 100 µF","cmc":"1,9 %"},{"name":"20 Hz až 50 Hz","range":"100 µF až 500 µF","cmc":"0,44 %"},{"name":"50 Hz až 70 Hz","range":"100 µF až 500 µF","cmc":"0,29 %"},{"name":"70 Hz až 200 Hz","range":"100 µF až 500 µF","cmc":"0,33 %"},{"name":"200 Hz až 300 Hz","range":"100 µF až 500 µF","cmc":"0,42 %"},{"name":"300 Hz až 400 Hz","range":"100 µF až 500 µF","cmc":"0,51 %"},{"name":"400 Hz až 500 Hz","range":"100 µF až 500 µF","cmc":"0,59 %"},{"name":"500 Hz až 600 Hz","range":"100 µF až 500 µF","cmc":"0,68 %"},{"name":"600 Hz až 700 Hz","range":"100 µF až 500 µF","cmc":"0,77 %"},{"name":"700 Hz až 800 Hz","range":"100 µF až 500 µF","cmc":"0,85 %"},{"name":"800 Hz až 900 Hz","range":"100 µF až 500 µF","cmc":"0,94 %"},{"name":"900 Hz až 2 kHz","range":"100 µF až 500 µF","cmc":"1,1 %"},{"name":"2 kHz až 3 kHz","range":"100 µF až 500 µF","cmc":"1,5 %"},{"name":"3 kHz až 4 kHz","range":"100 µF až 500 µF","cmc":"1,9 %"},{"name":"4 kHz až 5 kHz","range":"100 µF až 500 µF","cmc":"2,4 %"},{"name":"20 Hz až 50 Hz","range":"500 µF až 1 mF","cmc":"0,44 %"},{"name":"50 Hz až 70 Hz","range":"500 µF až 1 mF","cmc":"0,29 %"},{"name":"70 Hz až 200 Hz","range":"500 µF až 1 mF","cmc":"0,33 %"},{"name":"200 Hz až 300 Hz","range":"500 µF až 1 mF","cmc":"0,42 %"},{"name":"300 Hz až 400 Hz","range":"500 µF až 1 mF","cmc":"0,51 %"},{"name":"400 Hz až 500 Hz","range":"500 µF až 1 mF","cmc":"0,59 %"},{"name":"500 Hz až 600 Hz","range":"500 µF až 1 mF","cmc":"0,68 %"},{"name":"600 Hz až 700 Hz","range":"500 µF až 1 mF","cmc":"0,77 %"},{"name":"700 Hz až 800 Hz","range":"500 µF až 1 mF","cmc":"0,85 %"},{"name":"800 Hz až 900 Hz","range":"500 µF až 1 mF","cmc":"0,94 %"},{"name":"900 Hz až 1 kHz","range":"500 µF až 1 mF","cmc":"1,1 %"},{"name":"1 kHz až 2 kHz","range":"500 µF až 1 mF","cmc":"1,9 %"},{"name":"20 Hz až 30 Hz","range":"1 mF až 5 mF","cmc":"0,70 %"},{"name":"30 Hz až 40 Hz","range":"1 mF až 5 mF","cmc":"0,78 %"},{"name":"40 Hz až 80 Hz","range":"1 mF až 5 mF","cmc":"0,89 %"},{"name":"80 Hz až 90 Hz","range":"1 mF až 5 mF","cmc":"0,96 %"},{"name":"90 Hz až 160 Hz","range":"1 mF až 5 mF","cmc":"1,1 %"},{"name":"160 Hz až 300 Hz","range":"1 mF až 5 mF","cmc":"1,7 %"},{"name":"300 Hz až 400 Hz","range":"1 mF až 5 mF","cmc":"2,1 %"},{"name":"400 Hz až 500 Hz","range":"1 mF až 5 mF","cmc":"2,6 %"},{"name":"500 Hz až 600 Hz","range":"1 mF až 5 mF","cmc":"3,0 %"},{"name":"600 Hz až 700 Hz","range":"1 mF až 5 mF","cmc":"3,4 %"},{"name":"700 Hz až 800 Hz","range":"1 mF až 5 mF","cmc":"3,9 %"},{"name":"800 Hz až 900 Hz","range":"1 mF až 5 mF","cmc":"4,3 %"},{"name":"900 Hz až 1 kHz","range":"1 mF až 5 mF","cmc":"4,7 %"},{"name":"50 Hz až 60 Hz","range":"5 mF až 10 mF","cmc":"1,4 %"},{"name":"60 Hz až 160 Hz","range":"5 mF až 10 mF","cmc":"1,9 %"},{"name":"160 Hz až 220 Hz","range":"5 mF až 10 mF","cmc":"2,3 %"},{"name":"220 Hz až 300 Hz","range":"5 mF až 10 mF","cmc":"3,0 %"}],"technique":"Pomiar bezpośredni miernikiem RLC","technique_en":"Direct measurement by a RLC meter","technique_zh":"用 RLC 表直接测量","technique_cs":"Přímé měření RLC měřidlem","techniques":["Pomiar bezpośredni miernikiem RLC"],"techniques_en":["Direct measurement by a RLC meter"],"techniques_zh":["用 RLC 表直接测量"],"techniques_cs":["Přímé měření RLC měřidlem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 kHz do 15 kHz od 1 pF do 5 pF CMC 2,2 %\n15 kHz do 20 kHz od 1 pF do 5 pF CMC 1,5 %\n20 kHz do 25 kHz od 1 pF do 5 pF CMC 1,2 %\n25 kHz do 30 kHz od 1 pF do 5 pF CMC 0,94 %\n30 kHz do 40 kHz od 1 pF do 5 pF CMC 0,81 %\n40 kHz do 50 kHz od 1 pF do 5 pF CMC 0,65 %\n50 kHz do 60 kHz od 1 pF do 5 pF CMC 0,55 %\n60 kHz do 70 kHz od 1 pF do 5 pF CMC 0,49 %\n70 kHz do 80 kHz od 1 pF do 5 pF CMC 0,44 %\n80 kHz do 100 kHz od 1 pF do 5 pF CMC 0,40 %\n100 kHz do 110 kHz od 1 pF do 5 pF CMC 0,75 %\n110 kHz do 120 kHz od 1 pF do 5 pF CMC 0,69 %\n120 kHz do 130 kHz od 1 pF do 5 pF CMC 0,65 %\n130 kHz do 140 kHz od 1 pF do 5 pF CMC 0,61 %\n140 kHz do 150 kHz od 1 pF do 5 pF CMC 0,58 %\n150 kHz do 170 kHz od 1 pF do 5 pF CMC 0,55 %\n170 kHz do 200 kHz od 1 pF do 5 pF CMC 0,50 %\n200 kHz do 250 kHz od 1 pF do 5 pF CMC 0,45 %\n250 kHz do 300 kHz od 1 pF do 5 pF CMC 0,39 %\n300 kHz do 350 kHz od 1 pF do 5 pF CMC 0,81 %\n350 kHz do 400 kHz od 1 pF do 5 pF CMC 0,72 %\n400 kHz do 450 kHz od 1 pF do 5 pF CMC 0,65 %\n450 kHz do 500 kHz od 1 pF do 5 pF CMC 0,59 %\n500 kHz do 600 kHz od 1 pF do 5 pF CMC 0,55 %\n600 kHz do 700 kHz od 1 pF do 5 pF CMC 0,49 %\n700 kHz do 800 kHz od 1 pF do 5 pF CMC 0,44 %\n800 kHz do 1 MHz od 1 pF do 5 pF CMC 0,40 %\n1 kHz do 2 kHz od 5 pF do 10 pF CMC 4,1 %\n2 kHz do 3 kHz od 5 pF do 10 pF CMC 2,2 %\n3 kHz do 4 kHz od 5 pF do 10 pF CMC 1,5 %\n4 kHz do 5 kHz od 5 pF do 10 pF CMC 1,2 %\n5 kHz do 6 kHz od 5 pF do 10 pF CMC 0,94 %\n6 kHz do 7 kHz od 5 pF do 10 pF CMC 0,81 %\n7 kHz do 8 kHz od 5 pF do 10 pF CMC 0,72 %\n8 kHz do 9 kHz od 5 pF do 10 pF CMC 0,65 %\n9 kHz do 10 kHz od 5 pF do 10 pF CMC 0,59 %\n10 kHz do 15 kHz od 5 pF do 10 pF CMC 0,55 %\n15 kHz do 20 kHz od 5 pF do 10 pF CMC 0,42 %\n20 kHz do 25 kHz od 5 pF do 10 pF CMC 0,36 %\n25 kHz do 30 kHz od 5 pF do 10 pF CMC 0,32 %\n30 kHz do 1 MHz od 5 pF do 10 pF CMC 0,29 %\n500 Hz do 600 Hz od 10 pF do 50 pF CMC 4,3 %\n600 Hz do 700 Hz od 10 pF do 50 pF CMC 3,7 %\n700 Hz do 800 Hz od 10 pF do 50 pF CMC 3,2 %\n800 Hz do 900 Hz od 10 pF do 50 pF CMC 2,8 %\n900 Hz do 1 kHz od 10 pF do 50 pF CMC 2,6 %\n1 kHz do 2 kHz od 10 pF do 50 pF CMC 2,2 %\n2 kHz do 3 kHz od 10 pF do 50 pF CMC 1,2 %\n3 kHz do 4 kHz od 10 pF do 50 pF CMC 0,81 %\n4 kHz do 5 kHz od 10 pF do 50 pF CMC 0,65 %\n5 kHz do 6 kHz od 10 pF do 50 pF CMC 0,55 %\n6 kHz do 7 kHz od 10 pF do 50 pF CMC 0,49 %\n7 kHz do 8 kHz od 10 pF do 50 pF CMC 0,44 %\n8 kHz do 9 kHz od 10 pF do 50 pF CMC 0,40 %\n9 kHz do 10 kHz od 10 pF do 50 pF CMC 0,38 %\n10 kHz do 15 kHz od 10 pF do 50 pF CMC 0,36 %\n15 kHz do 20 kHz od 10 pF do 50 pF CMC 0,29 %\n20 kHz do 1 MHz od 10 pF do 50 pF CMC 0,26 %\n100 Hz do 200 Hz od 50 pF do 100 pF CMC 4,3 %\n200 Hz do 300 Hz od 50 pF do 100 pF CMC 2,3 %\n300 Hz do 400 Hz od 50 pF do 100 pF CMC 1,7 %\n400 Hz do 500 Hz od 50 pF do 100 pF CMC 1,4 %\n500 Hz do 600 Hz od 50 pF do 100 pF CMC 1,2 %\n600 Hz do 700 Hz od 50 pF do 100 pF CMC 0,99 %\n700 Hz do 800 Hz od 50 pF do 100 pF CMC 0,89 %\n800 Hz do 900 Hz od 50 pF do 100 pF CMC 0,82 %\n900 Hz do 1 kHz od 50 pF do 100 pF CMC 0,77 %\n1 kHz do 2 kHz od 50 pF do 100 pF CMC 0,55 %\n2 kHz do 3 kHz od 50 pF do 100 pF CMC 0,36 %\n3 kHz do 4 kHz od 50 pF do 100 pF CMC 0,29 %\n4 kHz do 5 kHz od 50 pF do 100 pF CMC 0,26 %\n5 kHz do 1 MHz od 50 pF do 100 pF CMC 0,24 %\n50 Hz do 60 Hz od 100 pF do 500 pF CMC 9,9 %\n60 Hz do 70 Hz od 100 pF do 500 pF CMC 7,9 %\n70 Hz do 80 Hz od 100 pF do 500 pF CMC 6,5 %\n80 Hz do 90 Hz od 100 pF do 500 pF CMC 5,6 %\n90 Hz do 100 Hz od 100 pF do 500 pF CMC 4,9 %\n100 Hz do 160 Hz od 100 pF do 500 pF CMC 2,3 %\n160 Hz do 200 Hz od 100 pF do 500 pF CMC 1,4 %\n200 Hz do 300 Hz od 100 pF do 500 pF CMC 1,2 %\n300 Hz do 400 Hz od 100 pF do 500 pF CMC 0,81 %\n400 Hz do 500 Hz od 100 pF do 500 pF CMC 0,65 %\n500 Hz do 600 Hz od 100 pF do 500 pF CMC 0,55 %\n600 Hz do 700 Hz od 100 pF do 500 pF CMC 0,49 %\n700 Hz do 800 Hz od 100 pF do 500 pF CMC 0,44 %\n800 Hz do 900 Hz od 100 pF do 500 pF CMC 0,40 %\n900 Hz do 1 kHz od 100 pF do 500 pF CMC 0,38 %\n1 kHz do 2 kHz od 100 pF do 500 pF CMC 0,36 %\n2 kHz do 3 kHz od 100 pF do 500 pF CMC 0,26 %\n3 kHz do 4 kHz od 100 pF do 500 pF CMC 0,23 %\n4 kHz do 5 kHz od 100 pF do 500 pF CMC 0,21 %\n5 kHz do 1 MHz od 100 pF do 500 pF CMC 0,17 %\n50 Hz do 60 Hz od 500 pF do 1 nF CMC 2,3 %\n60 Hz do 70 Hz od 500 pF do 1 nF CMC 1,9 %\n70 Hz do 80 Hz od 500 pF do 1 nF CMC 1,6 %\n80 Hz do 100 Hz od 500 pF do 1 nF CMC 1,4 %\n100 Hz do 160 Hz od 500 pF do 1 nF CMC 0,72 %\n160 Hz do 200 Hz od 500 pF do 1 nF CMC 0,40 %\n200 Hz do 300 Hz od 500 pF do 1 nF CMC 0,36 %\n300 Hz do 400 Hz od 500 pF do 1 nF CMC 0,29 %\n400 Hz do 500 Hz od 500 pF do 1 nF CMC 0,26 %\n500 Hz do 700 Hz od 500 pF do 1 nF CMC 0,24 %\n700 Hz do 1 kHz od 500 pF do 1 nF CMC 0,22 %\n1 kHz do 2 kHz od 500 pF do 1 nF CMC 0,36 %\n2 kHz do 3 kHz od 500 pF do 1 nF CMC 0,26 %\n3 kHz do 4 kHz od 500 pF do 1 nF CMC 0,23 %\n4 kHz do 5 kHz od 500 pF do 1 nF CMC 0,21 %\n5 kHz do 1 MHz od 500 pF do 1 nF CMC 0,17 %\n20 Hz do 30 Hz od 1 nF do 5 nF CMC 3,6 %\n30 Hz do 40 Hz od 1 nF do 5 nF CMC 2,2 %\n40 Hz do 50 Hz od 1 nF do 5 nF CMC 1,6 %\n50 Hz do 60 Hz od 1 nF do 5 nF CMC 1,2 %\n60 Hz do 70 Hz od 1 nF do 5 nF CMC 0,91 %\n70 Hz do 80 Hz od 1 nF do 5 nF CMC 0,77 %\n80 Hz do 90 Hz od 1 nF do 5 nF CMC 0,68 %\n90 Hz do 100 Hz od 1 nF do 5 nF CMC 0,61 %\n100 Hz do 200 Hz od 1 nF do 5 nF CMC 0,36 %\n200 Hz do 300 Hz od 1 nF do 5 nF CMC 0,26 %\n300 Hz do 500 Hz od 1 nF do 5 nF CMC 0,23 %\n500 Hz do 1 MHz od 1 nF do 5 nF CMC 0,15 %\n20 Hz do 30 Hz od 5 nF do 10 nF CMC 0,97 %\n30 Hz do 40 Hz od 5 nF do 10 nF CMC 0,70 %\n40 Hz do 50 Hz od 5 nF do 10 nF CMC 0,58 %\n50 Hz do 60 Hz od 5 nF do 10 nF CMC 0,35 %\n60 Hz do 70 Hz od 5 nF do 10 nF CMC 0,31 %\n70 Hz do 100 Hz od 5 nF do 10 nF CMC 0,28 %\n100 Hz do 400 Hz od 5 nF do 10 nF CMC 0,20 %\n400 Hz do 500 Hz od 5 nF do 10 nF CMC 0,17 %\n500 Hz do 1 MHz od 5 nF do 10 nF CMC 0,13 %\n20 Hz do 30 Hz od 10 nF do 50 nF CMC 0,65 %\n30 Hz do 40 Hz od 10 nF do 50 nF CMC 0,52 %\n40 Hz do 50 Hz od 10 nF do 50 nF CMC 0,46 %\n50 Hz do 70 Hz od 10 nF do 50 nF CMC 0,26 %\n70 Hz do 100 Hz od 10 nF do 50 nF CMC 0,22 %\n100 Hz do 103 kHz od 10 nF do 50 nF CMC 0,13 %\n103 kHz do 150 kHz od 10 nF do 50 nF CMC 0,19 %\n150 kHz do 300 kHz od 10 nF do 50 nF CMC 0,21 %\n300 kHz do 500 kHz od 10 nF do 50 nF CMC 0,28 %\n500 kHz do 1 MHz od 10 nF do 50 nF CMC 0,39 %\n20 Hz do 40 Hz od 50 nF do 100 nF CMC 0,40 %\n40 Hz do 50 Hz od 50 nF do 100 nF CMC 0,36 %\n50 Hz do 70 Hz od 50 nF do 100 nF CMC 0,26 %\n70 Hz do 100 Hz od 50 nF do 100 nF CMC 0,22 %\n100 Hz do 103 kHz od 50 nF do 100 nF CMC 0,13 %\n103 kHz do 150 kHz od 50 nF do 100 nF CMC 0,19 %\n150 kHz do 300 kHz od 50 nF do 100 nF CMC 0,21 %\n300 kHz do 500 kHz od 50 nF do 100 nF CMC 0,28 %\n500 kHz do 1 MHz od 50 nF do 100 nF CMC 0,39 %\n20 Hz do 50 Hz od 100 nF do 500 nF CMC 0,36 %\n50 Hz do 100 Hz od 100 nF do 500 nF CMC 0,18 %\n100 Hz do 10 kHz od 100 nF do 500 nF CMC 0,12 %\n10 kHz do 70 kHz od 100 nF do 500 nF CMC 0,22 %\n70 kHz do 100 kHz od 100 nF do 500 nF CMC 0,25 %\n100 kHz do 140 kHz od 100 nF do 500 nF CMC 0,27 %\n140 kHz do 230 kHz od 100 nF do 500 nF CMC 0,34 %\n230 kHz do 280 kHz od 100 nF do 500 nF CMC 0,38 %\n280 kHz do 300 kHz od 100 nF do 500 nF CMC 0,40 %\n300 kHz do 350 kHz od 100 nF do 500 nF CMC 0,56 %\n350 kHz do 400 kHz od 100 nF do 500 nF CMC 0,62 %\n400 kHz do 450 kHz od 100 nF do 500 nF CMC 0,68 %\n450 kHz do 500 kHz od 100 nF do 500 nF CMC 0,74 %\n500 kHz do 600 kHz od 100 nF do 500 nF CMC 0,86 %\n600 kHz do 700 kHz od 100 nF do 500 nF CMC 0,97 %\n700 kHz do 800 kHz od 100 nF do 500 nF CMC 1,1 %\n800 kHz do 1 MHz od 100 nF do 500 nF CMC 1,4 %\n20 Hz do 50 Hz od 500 nF do 1 µF CMC 0,36 %\n50 Hz do 100 Hz od 500 nF do 1 µF CMC 0,18 %\n100 Hz do 10 kHz od 500 nF do 1 µF CMC 0,12 %\n10 kHz do 70 kHz od 500 nF do 1 µF CMC 0,22 %\n70 kHz do 100 kHz od 500 nF do 1 µF CMC 0,25 %\n100 kHz do 120 kHz od 500 nF do 1 µF CMC 0,35 %\n120 kHz do 150 kHz od 500 nF do 1 µF CMC 0,40 %\n150 kHz do 180 kHz od 500 nF do 1 µF CMC 0,45 %\n180 kHz do 220 kHz od 500 nF do 1 µF CMC 0,51 %\n220 kHz do 250 kHz od 500 nF do 1 µF CMC 0,56 %\n250 kHz do 300 kHz od 500 nF do 1 µF CMC 0,64 %\n300 kHz do 350 kHz od 500 nF do 1 µF CMC 0,97 %\n350 kHz do 400 kHz od 500 nF do 1 µF CMC 1,1 %\n400 kHz do 500 kHz od 500 nF do 1 µF CMC 1,4 %\n500 kHz do 600 kHz od 500 nF do 1 µF CMC 1,6 %\n600 kHz do 700 kHz od 500 nF do 1 µF CMC 1,8 %\n700 kHz do 1 MHz od 500 nF do 1 µF CMC 2,5 %\n20 Hz do 50 Hz od 1 µF do 5 µF CMC 0,34 %\n50 Hz do 5 kHz od 1 µF do 5 µF CMC 0,20 %\n5 kHz do 10 kHz od 1 µF do 5 µF CMC 0,25 %\n10 kHz do 15 kHz od 1 µF do 5 µF CMC 0,29 %\n15 kHz do 20 kHz od 1 µF do 5 µF CMC 0,33 %\n20 kHz do 25 kHz od 1 µF do 5 µF CMC 0,38 %\n25 kHz do 30 kHz od 1 µF do 5 µF CMC 0,42 %\n30 kHz do 40 kHz od 1 µF do 5 µF CMC 0,33 %\n40 kHz do 50 kHz od 1 µF do 5 µF CMC 0,38 %\n50 kHz do 60 kHz od 1 µF do 5 µF CMC 0,42 %\n60 kHz do 70 kHz od 1 µF do 5 µF CMC 0,46 %\n70 kHz do 80 kHz od 1 µF do 5 µF CMC 0,51 %\n80 kHz do 90 kHz od 1 µF do 5 µF CMC 0,55 %\n90 kHz do 100 kHz od 1 µF do 5 µF CMC 0,59 %\n100 kHz do 110 kHz od 1 µF do 5 µF CMC 1,1 %\n110 kHz do 140 kHz od 1 µF do 5 µF CMC 1,3 %\n140 kHz do 160 kHz od 1 µF do 5 µF CMC 1,5 %\n160 kHz do 190 kHz od 1 µF do 5 µF CMC 1,7 %\n190 kHz do 210 kHz od 1 µF do 5 µF CMC 1,9 %\n210 kHz do 250 kHz od 1 µF do 5 µF CMC 2,2 %\n250 kHz do 300 kHz od 1 µF do 5 µF CMC 2,6 %\n300 kHz do 350 kHz od 1 µF do 5 µF CMC 4,3 %\n350 kHz do 400 kHz od 1 µF do 5 µF CMC 4,9 %\n400 kHz do 450 kHz od 1 µF do 5 µF CMC 5,4 %\n450 kHz do 500 kHz od 1 µF do 5 µF CMC 6,0 %\n20 Hz do 50 Hz od 5 µF do 10 µF CMC 0,34 %\n50 Hz do 5 kHz od 5 µF do 10 µF CMC 0,20 %\n5 kHz do 10 kHz od 5 µF do 10 µF CMC 0,25 %\n10 kHz do 15 kHz od 5 µF do 10 µF CMC 0,29 %\n15 kHz do 20 kHz od 5 µF do 10 µF CMC 0,33 %\n20 kHz do 25 kHz od 5 µF do 10 µF CMC 0,38 %\n25 kHz do 30 kHz od 5 µF do 10 µF CMC 0,42 %\n30 kHz do 40 kHz od 5 µF do 10 µF CMC 0,51 %\n40 kHz do 50 kHz od 5 µF do 10 µF CMC 0,59 %\n50 kHz do 60 kHz od 5 µF do 10 µF CMC 0,68 %\n60 kHz do 70 kHz od 5 µF do 10 µF CMC 0,77 %\n70 kHz do 80 kHz od 5 µF do 10 µF CMC 0,85 %\n80 kHz do 90 kHz od 5 µF do 10 µF CMC 0,94 %\n90 kHz do 100 kHz od 5 µF do 10 µF CMC 1,1 %\n100 kHz do 110 kHz od 5 µF do 10 µF CMC 2,0 %\n110 kHz do 140 kHz od 5 µF do 10 µF CMC 2,4 %\n140 kHz do 160 kHz od 5 µF do 10 µF CMC 2,8 %\n160 kHz do 190 kHz od 5 µF do 10 µF CMC 3,2 %\n190 kHz do 210 kHz od 5 µF do 10 µF CMC 3,6 %\n210 kHz do 250 kHz od 5 µF do 10 µF CMC 4,2 %\n250 kHz do 300 kHz od 5 µF do 10 µF CMC 5,0 %\n20 Hz do 50 Hz od 10 µF do 20 µF CMC 0,34 %\n50 Hz do 500 Hz od 10 µF do 20 µF CMC 0,20 %\n500 Hz do 700 Hz od 10 µF do 20 µF CMC 0,22 %\n700 Hz do 1 kHz od 10 µF do 20 µF CMC 0,25 %\n1 kHz do 2 kHz od 10 µF do 20 µF CMC 0,33 %\n2 kHz do 3 kHz od 10 µF do 20 µF CMC 0,42 %\n3 kHz do 4 kHz od 10 µF do 20 µF CMC 0,51 %\n4 kHz do 5 kHz od 10 µF do 20 µF CMC 0,59 %\n5 kHz do 6 kHz od 10 µF do 20 µF CMC 0,68 %\n6 kHz do 7 kHz od 10 µF do 20 µF CMC 0,77 %\n7 kHz do 8 kHz od 10 µF do 20 µF CMC 0,85 %\n8 kHz do 9 kHz od 10 µF do 20 µF CMC 0,94 %\n9 kHz do 10 kHz od 10 µF do 20 µF CMC 1,1 %\n10 kHz do 15 kHz od 10 µF do 20 µF CMC 1,5 %\n15 kHz do 20 kHz od 10 µF do 20 µF CMC 1,9 %\n20 kHz do 25 kHz od 10 µF do 20 µF CMC 2,4 %\n25 kHz do 30 kHz od 10 µF do 20 µF CMC 2,8 %\n30 kHz do 40 kHz od 10 µF do 20 µF CMC 1,9 %\n40 kHz do 50 kHz od 10 µF do 20 µF CMC 2,4 %\n50 kHz do 60 kHz od 10 µF do 20 µF CMC 2,8 %\n60 kHz do 70 kHz od 10 µF do 20 µF CMC 3,2 %\n70 kHz do 80 kHz od 10 µF do 20 µF CMC 3,7 %\n80 kHz do 90 kHz od 10 µF do 20 µF CMC 4,1 %\n90 kHz do 100 kHz od 10 µF do 20 µF CMC 4,6 %\n20 Hz do 50 Hz od 20 µF do 50 µF CMC 0,34 %\n50 Hz do 500 Hz od 20 µF do 50 µF CMC 0,20 %\n500 Hz do 700 Hz od 20 µF do 50 µF CMC 0,22 %\n700 Hz do 1 kHz od 20 µF do 50 µF CMC 0,25 %\n1 kHz do 2 kHz od 20 µF do 50 µF CMC 0,33 %\n2 kHz do 3 kHz od 20 µF do 50 µF CMC 0,42 %\n3 kHz do 4 kHz od 20 µF do 50 µF CMC 0,51 %\n4 kHz do 5 kHz od 20 µF do 50 µF CMC 0,59 %\n5 kHz do 6 kHz od 20 µF do 50 µF CMC 0,68 %\n6 kHz do 7 kHz od 20 µF do 50 µF CMC 0,77 %\n7 kHz do 8 kHz od 20 µF do 50 µF CMC 0,85 %\n8 kHz do 9 kHz od 20 µF do 50 µF CMC 0,94 %\n9 kHz do 10 kHz od 20 µF do 50 µF CMC 1,1 %\n10 kHz do 15 kHz od 20 µF do 50 µF CMC 1,5 %\n15 kHz do 20 kHz od 20 µF do 50 µF CMC 1,9 %\n20 kHz do 25 kHz od 20 µF do 50 µF CMC 2,4 %\n25 kHz do 30 kHz od 20 µF do 50 µF CMC 2,8 %\n30 kHz do 40 kHz od 20 µF do 50 µF CMC 1,9 %\n40 kHz do 50 kHz od 20 µF do 50 µF CMC 2,4 %\n20 Hz do 50 Hz od 50 µF do 100 µF CMC 0,34 %\n50 Hz do 500 Hz od 50 µF do 100 µF CMC 0,20 %\n500 Hz do 700 Hz od 50 µF do 100 µF CMC 0,22 %\n700 Hz do 1 kHz od 50 µF do 100 µF CMC 0,25 %\n1 kHz do 2 kHz od 50 µF do 100 µF CMC 0,33 %\n2 kHz do 3 kHz od 50 µF do 100 µF CMC 0,42 %\n3 kHz do 4 kHz od 50 µF do 100 µF CMC 0,51 %\n4 kHz do 5 kHz od 50 µF do 100 µF CMC 0,59 %\n5 kHz do 6 kHz od 50 µF do 100 µF CMC 0,68 %\n6 kHz do 7 kHz od 50 µF do 100 µF CMC 0,77 %\n7 kHz do 8 kHz od 50 µF do 100 µF CMC 0,85 %\n8 kHz do 9 kHz od 50 µF do 100 µF CMC 0,94 %\n9 kHz do 10 kHz od 50 µF do 100 µF CMC 1,1 %\n10 kHz do 15 kHz od 50 µF do 100 µF CMC 1,5 %\n15 kHz do 20 kHz od 50 µF do 100 µF CMC 1,9 %\n20 Hz do 50 Hz od 100 µF do 500 µF CMC 0,44 %\n50 Hz do 70 Hz od 100 µF do 500 µF CMC 0,29 %\n70 Hz do 200 Hz od 100 µF do 500 µF CMC 0,33 %\n200 Hz do 300 Hz od 100 µF do 500 µF CMC 0,42 %\n300 Hz do 400 Hz od 100 µF do 500 µF CMC 0,51 %\n400 Hz do 500 Hz od 100 µF do 500 µF CMC 0,59 %\n500 Hz do 600 Hz od 100 µF do 500 µF CMC 0,68 %\n600 Hz do 700 Hz od 100 µF do 500 µF CMC 0,77 %\n700 Hz do 800 Hz od 100 µF do 500 µF CMC 0,85 %\n800 Hz do 900 Hz od 100 µF do 500 µF CMC 0,94 %\n900 Hz do 2 kHz od 100 µF do 500 µF CMC 1,1 %\n2 kHz do 3 kHz od 100 µF do 500 µF CMC 1,5 %\n3 kHz do 4 kHz od 100 µF do 500 µF CMC 1,9 %\n4 kHz do 5 kHz od 100 µF do 500 µF CMC 2,4 %\n20 Hz do 50 Hz od 500 µF do 1 mF CMC 0,44 %\n50 Hz do 70 Hz od 500 µF do 1 mF CMC 0,29 %\n70 Hz do 200 Hz od 500 µF do 1 mF CMC 0,33 %\n200 Hz do 300 Hz od 500 µF do 1 mF CMC 0,42 %\n300 Hz do 400 Hz od 500 µF do 1 mF CMC 0,51 %\n400 Hz do 500 Hz od 500 µF do 1 mF CMC 0,59 %\n500 Hz do 600 Hz od 500 µF do 1 mF CMC 0,68 %\n600 Hz do 700 Hz od 500 µF do 1 mF CMC 0,77 %\n700 Hz do 800 Hz od 500 µF do 1 mF CMC 0,85 %\n800 Hz do 900 Hz od 500 µF do 1 mF CMC 0,94 %\n900 Hz do 1 kHz od 500 µF do 1 mF CMC 1,1 %\n1 kHz do 2 kHz od 500 µF do 1 mF CMC 1,9 %\n20 Hz do 30 Hz od 1 mF do 5 mF CMC 0,70 %\n30 Hz do 40 Hz od 1 mF do 5 mF CMC 0,78 %\n40 Hz do 80 Hz od 1 mF do 5 mF CMC 0,89 %\n80 Hz do 90 Hz od 1 mF do 5 mF CMC 0,96 %\n90 Hz do 160 Hz od 1 mF do 5 mF CMC 1,1 %\n160 Hz do 300 Hz od 1 mF do 5 mF CMC 1,7 %\n300 Hz do 400 Hz od 1 mF do 5 mF CMC 2,1 %\n400 Hz do 500 Hz od 1 mF do 5 mF CMC 2,6 %\n500 Hz do 600 Hz od 1 mF do 5 mF CMC 3,0 %\n600 Hz do 700 Hz od 1 mF do 5 mF CMC 3,4 %\n700 Hz do 800 Hz od 1 mF do 5 mF CMC 3,9 %\n800 Hz do 900 Hz od 1 mF do 5 mF CMC 4,3 %\n900 Hz do 1 kHz od 1 mF do 5 mF CMC 4,7 %\n50 Hz do 60 Hz od 5 mF do 10 mF CMC 1,4 %\n60 Hz do 160 Hz od 5 mF do 10 mF CMC 1,9 %\n160 Hz do 220 Hz od 5 mF do 10 mF CMC 2,3 %\n220 Hz do 300 Hz od 5 mF do 10 mF CMC 3,0 %\nPomiar bezpośredni miernikiem RLC","reference":"TP7, TP24","norm_bases":["TP7","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / Wzorce pojemności Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem RLC 10 kHz do 15 kHz od 1 pF do 5 pF CMC 2,2 % 15 kHz do 20 kHz od 1 pF do 5 pF CMC 1,5 % 20 kHz do 25 kHz od 1 pF do 5 pF CMC 1,2 % 25 kHz do 30 kHz od 1 pF do 5 pF CMC 0,94 % 30 kHz do 40 kHz od 1 pF do 5 pF CMC 0,81 % 40 kHz do 50 kHz od 1 pF do 5 pF CMC 0,65 % 50 kHz do 60 kHz od 1 pF do 5 pF CMC 0,55 % 60 kHz do 70 kHz od 1 pF do 5 pF CMC 0,49 % 70 kHz do 80 kHz od 1 pF do 5 pF CMC 0,44 % 80 kHz do 100 kHz od 1 pF do 5 pF CMC 0,40 % 100 kHz do 110 kHz od 1 pF do 5 pF CMC 0,75 % 110 kHz do 120 kHz od 1 pF do 5 pF CMC 0,69 % 120 kHz do 130 kHz od 1 pF do 5 pF CMC 0,65 % 130 kHz do 140 kHz od 1 pF do 5 pF CMC 0,61 % 140 kHz do 150 kHz od 1 pF do 5 pF CMC 0,58 % 150 kHz do 170 kHz od 1 pF do 5 pF CMC 0,55 % 170 kHz do 200 kHz od 1 pF do 5 pF CMC 0,50 % 200 kHz do 250 kHz od 1 pF do 5 pF CMC 0,45 % 250 kHz do 300 kHz od 1 pF do 5 pF CMC 0,39 % 300 kHz do 350 kHz od 1 pF do 5 pF CMC 0,81 % 350 kHz do 400 kHz od 1 pF do 5 pF CMC 0,72 % 400 kHz do 450 kHz od 1 pF do 5 pF CMC 0,65 % 450 kHz do 500 kHz od 1 pF do 5 pF CMC 0,59 % 500 kHz do 600 kHz od 1 pF do 5 pF CMC 0,55 % 600 kHz do 700 kHz od 1 pF do 5 pF CMC 0,49 % 700 kHz do 800 kHz od 1 pF do 5 pF CMC 0,44 % 800 kHz do 1 MHz od 1 pF do 5 pF CMC 0,40 % 1 kHz do 2 kHz od 5 pF do 10 pF CMC 4,1 % 2 kHz do 3 kHz od 5 pF do 10 pF CMC 2,2 % 3 kHz do 4 kHz od 5 pF do 10 pF CMC 1,5 % 4 kHz do 5 kHz od 5 pF do 10 pF CMC 1,2 % 5 kHz do 6 kHz od 5 pF do 10 pF CMC 0,94 % 6 kHz do 7 kHz od 5 pF do 10 pF CMC 0,81 % 7 kHz do 8 kHz od 5 pF do 10 pF CMC 0,72 % 8 kHz do 9 kHz od 5 pF do 10 pF CMC 0,65 % 9 kHz do 10 kHz od 5 pF do 10 pF CMC 0,59 % 10 kHz do 15 kHz od 5 pF do 10 pF CMC 0,55 % 15 kHz do 20 kHz od 5 pF do 10 pF CMC 0,42 % 20 kHz do 25 kHz od 5 pF do 10 pF CMC 0,36 % 25 kHz do 30 kHz od 5 pF do 10 pF CMC 0,32 % 30 kHz do 1 MHz od 5 pF do 10 pF CMC 0,29 % 500 Hz do 600 Hz od 10 pF do 50 pF CMC 4,3 % 600 Hz do 700 Hz od 10 pF do 50 pF CMC 3,7 % 700 Hz do 800 Hz od 10 pF do 50 pF CMC 3,2 % 800 Hz do 900 Hz od 10 pF do 50 pF CMC 2,8 % 900 Hz do 1 kHz od 10 pF do 50 pF CMC 2,6 % 1 kHz do 2 kHz od 10 pF do 50 pF CMC 2,2 % 2 kHz do 3 kHz od 10 pF do 50 pF CMC 1,2 % 3 kHz do 4 kHz od 10 pF do 50 pF CMC 0,81 % 4 kHz do 5 kHz od 10 pF do 50 pF CMC 0,65 % 5 kHz do 6 kHz od 10 pF do 50 pF CMC 0,55 % 6 kHz do 7 kHz od 10 pF do 50 pF CMC 0,49 % 7 kHz do 8 kHz od 10 pF do 50 pF CMC 0,44 % 8 kHz do 9 kHz od 10 pF do 50 pF CMC 0,40 % 9 kHz do 10 kHz od 10 pF do 50 pF CMC 0,38 % 10 kHz do 15 kHz od 10 pF do 50 pF CMC 0,36 % 15 kHz do 20 kHz od 10 pF do 50 pF CMC 0,29 % 20 kHz do 1 MHz od 10 pF do 50 pF CMC 0,26 % 100 Hz do 200 Hz od 50 pF do 100 pF CMC 4,3 % 200 Hz do 300 Hz od 50 pF do 100 pF CMC 2,3 % 300 Hz do 400 Hz od 50 pF do 100 pF CMC 1,7 % 400 Hz do 500 Hz od 50 pF do 100 pF CMC 1,4 % 500 Hz do 600 Hz od 50 pF do 100 pF CMC 1,2 % 600 Hz do 700 Hz od 50 pF do 100 pF CMC 0,99 % 700 Hz do 800 Hz od 50 pF do 100 pF CMC 0,89 % 800 Hz do 900 Hz od 50 pF do 100 pF CMC 0,82 % 900 Hz do 1 kHz od 50 pF do 100 pF CMC 0,77 % 1 kHz do 2 kHz od 50 pF do 100 pF CMC 0,55 % 2 kHz do 3 kHz od 50 pF do 100 pF CMC 0,36 % 3 kHz do 4 kHz od 50 pF do 100 pF CMC 0,29 % 4 kHz do 5 kHz od 50 pF do 100 pF CMC 0,26 % 5 kHz do 1 MHz od 50 pF do 100 pF CMC 0,24 % 50 Hz do 60 Hz od 100 pF do 500 pF CMC 9,9 % 60 Hz do 70 Hz od 100 pF do 500 pF CMC 7,9 % 70 Hz do 80 Hz od 100 pF do 500 pF CMC 6,5 % 80 Hz do 90 Hz od 100 pF do 500 pF CMC 5,6 % 90 Hz do 100 Hz od 100 pF do 500 pF CMC 4,9 % 100 Hz do 160 Hz od 100 pF do 500 pF CMC 2,3 % 160 Hz do 200 Hz od 100 pF do 500 pF CMC 1,4 % 200 Hz do 300 Hz od 100 pF do 500 pF CMC 1,2 % 300 Hz do 400 Hz od 100 pF do 500 pF CMC 0,81 % 400 Hz do 500 Hz od 100 pF do 500 pF CMC 0,65 % 500 Hz do 600 Hz od 100 pF do 500 pF CMC 0,55 % 600 Hz do 700 Hz od 100 pF do 500 pF CMC 0,49 % 700 Hz do 800 Hz od 100 pF do 500 pF CMC 0,44 % 800 Hz do 900 Hz od 100 pF do 500 pF CMC 0,40 % 900 Hz do 1 kHz od 100 pF do 500 pF CMC 0,38 % 1 kHz do 2 kHz od 100 pF do 500 pF CMC 0,36 % 2 kHz do 3 kHz od 100 pF do 500 pF CMC 0,26 % 3 kHz do 4 kHz od 100 pF do 500 pF CMC 0,23 % 4 kHz do 5 kHz od 100 pF do 500 pF CMC 0,21 % 5 kHz do 1 MHz od 100 pF do 500 pF CMC 0,17 % 50 Hz do 60 Hz od 500 pF do 1 nF CMC 2,3 % 60 Hz do 70 Hz od 500 pF do 1 nF CMC 1,9 % 70 Hz do 80 Hz od 500 pF do 1 nF CMC 1,6 % 80 Hz do 100 Hz od 500 pF do 1 nF CMC 1,4 % 100 Hz do 160 Hz od 500 pF do 1 nF CMC 0,72 % 160 Hz do 200 Hz od 500 pF do 1 nF CMC 0,40 % 200 Hz do 300 Hz od 500 pF do 1 nF CMC 0,36 % 300 Hz do 400 Hz od 500 pF do 1 nF CMC 0,29 % 400 Hz do 500 Hz od 500 pF do 1 nF CMC 0,26 % 500 Hz do 700 Hz od 500 pF do 1 nF CMC 0,24 % 700 Hz do 1 kHz od 500 pF do 1 nF CMC 0,22 % 1 kHz do 2 kHz od 500 pF do 1 nF CMC 0,36 % 2 kHz do 3 kHz od 500 pF do 1 nF CMC 0,26 % 3 kHz do 4 kHz od 500 pF do 1 nF CMC 0,23 % 4 kHz do 5 kHz od 500 pF do 1 nF CMC 0,21 % 5 kHz do 1 MHz od 500 pF do 1 nF CMC 0,17 % 20 Hz do 30 Hz od 1 nF do 5 nF CMC 3,6 % 30 Hz do 40 Hz od 1 nF do 5 nF CMC 2,2 % 40 Hz do 50 Hz od 1 nF do 5 nF CMC 1,6 % 50 Hz do 60 Hz od 1 nF do 5 nF CMC 1,2 % 60 Hz do 70 Hz od 1 nF do 5 nF CMC 0,91 % 70 Hz do 80 Hz od 1 nF do 5 nF CMC 0,77 % 80 Hz do 90 Hz od 1 nF do 5 nF CMC 0,68 % 90 Hz do 100 Hz od 1 nF do 5 nF CMC 0,61 % 100 Hz do 200 Hz od 1 nF do 5 nF CMC 0,36 % 200 Hz do 300 Hz od 1 nF do 5 nF CMC 0,26 % 300 Hz do 500 Hz od 1 nF do 5 nF CMC 0,23 % 500 Hz do 1 MHz od 1 nF do 5 nF CMC 0,15 % 20 Hz do 30 Hz od 5 nF do 10 nF CMC 0,97 % 30 Hz do 40 Hz od 5 nF do 10 nF CMC 0,70 % 40 Hz do 50 Hz od 5 nF do 10 nF CMC 0,58 % 50 Hz do 60 Hz od 5 nF do 10 nF CMC 0,35 % 60 Hz do 70 Hz od 5 nF do 10 nF CMC 0,31 % 70 Hz do 100 Hz od 5 nF do 10 nF CMC 0,28 % 100 Hz do 400 Hz od 5 nF do 10 nF CMC 0,20 % 400 Hz do 500 Hz od 5 nF do 10 nF CMC 0,17 % 500 Hz do 1 MHz od 5 nF do 10 nF CMC 0,13 % 20 Hz do 30 Hz od 10 nF do 50 nF CMC 0,65 % 30 Hz do 40 Hz od 10 nF do 50 nF CMC 0,52 % 40 Hz do 50 Hz od 10 nF do 50 nF CMC 0,46 % 50 Hz do 70 Hz od 10 nF do 50 nF CMC 0,26 % 70 Hz do 100 Hz od 10 nF do 50 nF CMC 0,22 % 100 Hz do 103 kHz od 10 nF do 50 nF CMC 0,13 % 103 kHz do 150 kHz od 10 nF do 50 nF CMC 0,19 % 150 kHz do 300 kHz od 10 nF do 50 nF CMC 0,21 % 300 kHz do 500 kHz od 10 nF do 50 nF CMC 0,28 % 500 kHz do 1 MHz od 10 nF do 50 nF CMC 0,39 % 20 Hz do 40 Hz od 50 nF do 100 nF CMC 0,40 % 40 Hz do 50 Hz od 50 nF do 100 nF CMC 0,36 % 50 Hz do 70 Hz od 50 nF do 100 nF CMC 0,26 % 70 Hz do 100 Hz od 50 nF do 100 nF CMC 0,22 % 100 Hz do 103 kHz od 50 nF do 100 nF CMC 0,13 % 103 kHz do 150 kHz od 50 nF do 100 nF CMC 0,19 % 150 kHz do 300 kHz od 50 nF do 100 nF CMC 0,21 % 300 kHz do 500 kHz od 50 nF do 100 nF CMC 0,28 % 500 kHz do 1 MHz od 50 nF do 100 nF CMC 0,39 % 20 Hz do 50 Hz od 100 nF do 500 nF CMC 0,36 % 50 Hz do 100 Hz od 100 nF do 500 nF CMC 0,18 % 100 Hz do 10 kHz od 100 nF do 500 nF CMC 0,12 % 10 kHz do 70 kHz od 100 nF do 500 nF CMC 0,22 % 70 kHz do 100 kHz od 100 nF do 500 nF CMC 0,25 % 100 kHz do 140 kHz od 100 nF do 500 nF CMC 0,27 % 140 kHz do 230 kHz od 100 nF do 500 nF CMC 0,34 % 230 kHz do 280 kHz od 100 nF do 500 nF CMC 0,38 % 280 kHz do 300 kHz od 100 nF do 500 nF CMC 0,40 % 300 kHz do 350 kHz od 100 nF do 500 nF CMC 0,56 % 350 kHz do 400 kHz od 100 nF do 500 nF CMC 0,62 % 400 kHz do 450 kHz od 100 nF do 500 nF CMC 0,68 % 450 kHz do 500 kHz od 100 nF do 500 nF CMC 0,74 % 500 kHz do 600 kHz od 100 nF do 500 nF CMC 0,86 % 600 kHz do 700 kHz od 100 nF do 500 nF CMC 0,97 % 700 kHz do 800 kHz od 100 nF do 500 nF CMC 1,1 % 800 kHz do 1 MHz od 100 nF do 500 nF CMC 1,4 % 20 Hz do 50 Hz od 500 nF do 1 µF CMC 0,36 % 50 Hz do 100 Hz od 500 nF do 1 µF CMC 0,18 % 100 Hz do 10 kHz od 500 nF do 1 µF CMC 0,12 % 10 kHz do 70 kHz od 500 nF do 1 µF CMC 0,22 % 70 kHz do 100 kHz od 500 nF do 1 µF CMC 0,25 % 100 kHz do 120 kHz od 500 nF do 1 µF CMC 0,35 % 120 kHz do 150 kHz od 500 nF do 1 µF CMC 0,40 % 150 kHz do 180 kHz od 500 nF do 1 µF CMC 0,45 % 180 kHz do 220 kHz od 500 nF do 1 µF CMC 0,51 % 220 kHz do 250 kHz od 500 nF do 1 µF CMC 0,56 % 250 kHz do 300 kHz od 500 nF do 1 µF CMC 0,64 % 300 kHz do 350 kHz od 500 nF do 1 µF CMC 0,97 % 350 kHz do 400 kHz od 500 nF do 1 µF CMC 1,1 % 400 kHz do 500 kHz od 500 nF do 1 µF CMC 1,4 % 500 kHz do 600 kHz od 500 nF do 1 µF CMC 1,6 % 600 kHz do 700 kHz od 500 nF do 1 µF CMC 1,8 % 700 kHz do 1 MHz od 500 nF do 1 µF CMC 2,5 % 20 Hz do 50 Hz od 1 µF do 5 µF CMC 0,34 % 50 Hz do 5 kHz od 1 µF do 5 µF CMC 0,20 % 5 kHz do 10 kHz od 1 µF do 5 µF CMC 0,25 % 10 kHz do 15 kHz od 1 µF do 5 µF CMC 0,29 % 15 kHz do 20 kHz od 1 µF do 5 µF CMC 0,33 % 20 kHz do 25 kHz od 1 µF do 5 µF CMC 0,38 % 25 kHz do 30 kHz od 1 µF do 5 µF CMC 0,42 % 30 kHz do 40 kHz od 1 µF do 5 µF CMC 0,33 % 40 kHz do 50 kHz od 1 µF do 5 µF CMC 0,38 % 50 kHz do 60 kHz od 1 µF do 5 µF CMC 0,42 % 60 kHz do 70 kHz od 1 µF do 5 µF CMC 0,46 % 70 kHz do 80 kHz od 1 µF do 5 µF CMC 0,51 % 80 kHz do 90 kHz od 1 µF do 5 µF CMC 0,55 % 90 kHz do 100 kHz od 1 µF do 5 µF CMC 0,59 % 100 kHz do 110 kHz od 1 µF do 5 µF CMC 1,1 % 110 kHz do 140 kHz od 1 µF do 5 µF CMC 1,3 % 140 kHz do 160 kHz od 1 µF do 5 µF CMC 1,5 % 160 kHz do 190 kHz od 1 µF do 5 µF CMC 1,7 % 190 kHz do 210 kHz od 1 µF do 5 µF CMC 1,9 % 210 kHz do 250 kHz od 1 µF do 5 µF CMC 2,2 % 250 kHz do 300 kHz od 1 µF do 5 µF CMC 2,6 % 300 kHz do 350 kHz od 1 µF do 5 µF CMC 4,3 % 350 kHz do 400 kHz od 1 µF do 5 µF CMC 4,9 % 400 kHz do 450 kHz od 1 µF do 5 µF CMC 5,4 % 450 kHz do 500 kHz od 1 µF do 5 µF CMC 6,0 % 20 Hz do 50 Hz od 5 µF do 10 µF CMC 0,34 % 50 Hz do 5 kHz od 5 µF do 10 µF CMC 0,20 % 5 kHz do 10 kHz od 5 µF do 10 µF CMC 0,25 % 10 kHz do 15 kHz od 5 µF do 10 µF CMC 0,29 % 15 kHz do 20 kHz od 5 µF do 10 µF CMC 0,33 % 20 kHz do 25 kHz od 5 µF do 10 µF CMC 0,38 % 25 kHz do 30 kHz od 5 µF do 10 µF CMC 0,42 % 30 kHz do 40 kHz od 5 µF do 10 µF CMC 0,51 % 40 kHz do 50 kHz od 5 µF do 10 µF CMC 0,59 % 50 kHz do 60 kHz od 5 µF do 10 µF CMC 0,68 % 60 kHz do 70 kHz od 5 µF do 10 µF CMC 0,77 % 70 kHz do 80 kHz od 5 µF do 10 µF CMC 0,85 % 80 kHz do 90 kHz od 5 µF do 10 µF CMC 0,94 % 90 kHz do 100 kHz od 5 µF do 10 µF CMC 1,1 % 100 kHz do 110 kHz od 5 µF do 10 µF CMC 2,0 % 110 kHz do 140 kHz od 5 µF do 10 µF CMC 2,4 % 140 kHz do 160 kHz od 5 µF do 10 µF CMC 2,8 % 160 kHz do 190 kHz od 5 µF do 10 µF CMC 3,2 % 190 kHz do 210 kHz od 5 µF do 10 µF CMC 3,6 % 210 kHz do 250 kHz od 5 µF do 10 µF CMC 4,2 % 250 kHz do 300 kHz od 5 µF do 10 µF CMC 5,0 % 20 Hz do 50 Hz od 10 µF do 20 µF CMC 0,34 % 50 Hz do 500 Hz od 10 µF do 20 µF CMC 0,20 % 500 Hz do 700 Hz od 10 µF do 20 µF CMC 0,22 % 700 Hz do 1 kHz od 10 µF do 20 µF CMC 0,25 % 1 kHz do 2 kHz od 10 µF do 20 µF CMC 0,33 % 2 kHz do 3 kHz od 10 µF do 20 µF CMC 0,42 % 3 kHz do 4 kHz od 10 µF do 20 µF CMC 0,51 % 4 kHz do 5 kHz od 10 µF do 20 µF CMC 0,59 % 5 kHz do 6 kHz od 10 µF do 20 µF CMC 0,68 % 6 kHz do 7 kHz od 10 µF do 20 µF CMC 0,77 % 7 kHz do 8 kHz od 10 µF do 20 µF CMC 0,85 % 8 kHz do 9 kHz od 10 µF do 20 µF CMC 0,94 % 9 kHz do 10 kHz od 10 µF do 20 µF CMC 1,1 % 10 kHz do 15 kHz od 10 µF do 20 µF CMC 1,5 % 15 kHz do 20 kHz od 10 µF do 20 µF CMC 1,9 % 20 kHz do 25 kHz od 10 µF do 20 µF CMC 2,4 % 25 kHz do 30 kHz od 10 µF do 20 µF CMC 2,8 % 30 kHz do 40 kHz od 10 µF do 20 µF CMC 1,9 % 40 kHz do 50 kHz od 10 µF do 20 µF CMC 2,4 % 50 kHz do 60 kHz od 10 µF do 20 µF CMC 2,8 % 60 kHz do 70 kHz od 10 µF do 20 µF CMC 3,2 % 70 kHz do 80 kHz od 10 µF do 20 µF CMC 3,7 % 80 kHz do 90 kHz od 10 µF do 20 µF CMC 4,1 % 90 kHz do 100 kHz od 10 µF do 20 µF CMC 4,6 % 20 Hz do 50 Hz od 20 µF do 50 µF CMC 0,34 % 50 Hz do 500 Hz od 20 µF do 50 µF CMC 0,20 % 500 Hz do 700 Hz od 20 µF do 50 µF CMC 0,22 % 700 Hz do 1 kHz od 20 µF do 50 µF CMC 0,25 % 1 kHz do 2 kHz od 20 µF do 50 µF CMC 0,33 % 2 kHz do 3 kHz od 20 µF do 50 µF CMC 0,42 % 3 kHz do 4 kHz od 20 µF do 50 µF CMC 0,51 % 4 kHz do 5 kHz od 20 µF do 50 µF CMC 0,59 % 5 kHz do 6 kHz od 20 µF do 50 µF CMC 0,68 % 6 kHz do 7 kHz od 20 µF do 50 µF CMC 0,77 % 7 kHz do 8 kHz od 20 µF do 50 µF CMC 0,85 % 8 kHz do 9 kHz od 20 µF do 50 µF CMC 0,94 % 9 kHz do 10 kHz od 20 µF do 50 µF CMC 1,1 % 10 kHz do 15 kHz od 20 µF do 50 µF CMC 1,5 % 15 kHz do 20 kHz od 20 µF do 50 µF CMC 1,9 % 20 kHz do 25 kHz od 20 µF do 50 µF CMC 2,4 % 25 kHz do 30 kHz od 20 µF do 50 µF CMC 2,8 % 30 kHz do 40 kHz od 20 µF do 50 µF CMC 1,9 % 40 kHz do 50 kHz od 20 µF do 50 µF CMC 2,4 % 20 Hz do 50 Hz od 50 µF do 100 µF CMC 0,34 % 50 Hz do 500 Hz od 50 µF do 100 µF CMC 0,20 % 500 Hz do 700 Hz od 50 µF do 100 µF CMC 0,22 % 700 Hz do 1 kHz od 50 µF do 100 µF CMC 0,25 % 1 kHz do 2 kHz od 50 µF do 100 µF CMC 0,33 % 2 kHz do 3 kHz od 50 µF do 100 µF CMC 0,42 % 3 kHz do 4 kHz od 50 µF do 100 µF CMC 0,51 % 4 kHz do 5 kHz od 50 µF do 100 µF CMC 0,59 % 5 kHz do 6 kHz od 50 µF do 100 µF CMC 0,68 % 6 kHz do 7 kHz od 50 µF do 100 µF CMC 0,77 % 7 kHz do 8 kHz od 50 µF do 100 µF CMC 0,85 % 8 kHz do 9 kHz od 50 µF do 100 µF CMC 0,94 % 9 kHz do 10 kHz od 50 µF do 100 µF CMC 1,1 % 10 kHz do 15 kHz od 50 µF do 100 µF CMC 1,5 % 15 kHz do 20 kHz od 50 µF do 100 µF CMC 1,9 % 20 Hz do 50 Hz od 100 µF do 500 µF CMC 0,44 % 50 Hz do 70 Hz od 100 µF do 500 µF CMC 0,29 % 70 Hz do 200 Hz od 100 µF do 500 µF CMC 0,33 % 200 Hz do 300 Hz od 100 µF do 500 µF CMC 0,42 % 300 Hz do 400 Hz od 100 µF do 500 µF CMC 0,51 % 400 Hz do 500 Hz od 100 µF do 500 µF CMC 0,59 % 500 Hz do 600 Hz od 100 µF do 500 µF CMC 0,68 % 600 Hz do 700 Hz od 100 µF do 500 µF CMC 0,77 % 700 Hz do 800 Hz od 100 µF do 500 µF CMC 0,85 % 800 Hz do 900 Hz od 100 µF do 500 µF CMC 0,94 % 900 Hz do 2 kHz od 100 µF do 500 µF CMC 1,1 % 2 kHz do 3 kHz od 100 µF do 500 µF CMC 1,5 % 3 kHz do 4 kHz od 100 µF do 500 µF CMC 1,9 % 4 kHz do 5 kHz od 100 µF do 500 µF CMC 2,4 % 20 Hz do 50 Hz od 500 µF do 1 mF CMC 0,44 % 50 Hz do 70 Hz od 500 µF do 1 mF CMC 0,29 % 70 Hz do 200 Hz od 500 µF do 1 mF CMC 0,33 % 200 Hz do 300 Hz od 500 µF do 1 mF CMC 0,42 % 300 Hz do 400 Hz od 500 µF do 1 mF CMC 0,51 % 400 Hz do 500 Hz od 500 µF do 1 mF CMC 0,59 % 500 Hz do 600 Hz od 500 µF do 1 mF CMC 0,68 % 600 Hz do 700 Hz od 500 µF do 1 mF CMC 0,77 % 700 Hz do 800 Hz od 500 µF do 1 mF CMC 0,85 % 800 Hz do 900 Hz od 500 µF do 1 mF CMC 0,94 % 900 Hz do 1 kHz od 500 µF do 1 mF CMC 1,1 % 1 kHz do 2 kHz od 500 µF do 1 mF CMC 1,9 % 20 Hz do 30 Hz od 1 mF do 5 mF CMC 0,70 % 30 Hz do 40 Hz od 1 mF do 5 mF CMC 0,78 % 40 Hz do 80 Hz od 1 mF do 5 mF CMC 0,89 % 80 Hz do 90 Hz od 1 mF do 5 mF CMC 0,96 % 90 Hz do 160 Hz od 1 mF do 5 mF CMC 1,1 % 160 Hz do 300 Hz od 1 mF do 5 mF CMC 1,7 % 300 Hz do 400 Hz od 1 mF do 5 mF CMC 2,1 % 400 Hz do 500 Hz od 1 mF do 5 mF CMC 2,6 % 500 Hz do 600 Hz od 1 mF do 5 mF CMC 3,0 % 600 Hz do 700 Hz od 1 mF do 5 mF CMC 3,4 % 700 Hz do 800 Hz od 1 mF do 5 mF CMC 3,9 % 800 Hz do 900 Hz od 1 mF do 5 mF CMC 4,3 % 900 Hz do 1 kHz od 1 mF do 5 mF CMC 4,7 % 50 Hz do 60 Hz od 5 mF do 10 mF CMC 1,4 % 60 Hz do 160 Hz od 5 mF do 10 mF CMC 1,9 % 160 Hz do 220 Hz od 5 mF do 10 mF CMC 2,3 % 220 Hz do 300 Hz od 5 mF do 10 mF CMC 3,0 % Kapacita / Etalony kapacity Kalibrace – elektrické veličiny Přímé měření RLC měřidlem 10 kHz až 15 kHz 1 pF až 5 pF CMC 2,2 % 15 kHz až 20 kHz 1 pF až 5 pF CMC 1,5 % 20 kHz až 25 kHz 1 pF až 5 pF CMC 1,2 % 25 kHz až 30 kHz 1 pF až 5 pF CMC 0,94 % 30 kHz až 40 kHz 1 pF až 5 pF CMC 0,81 % 40 kHz až 50 kHz 1 pF až 5 pF CMC 0,65 % 50 kHz až 60 kHz 1 pF až 5 pF CMC 0,55 % 60 kHz až 70 kHz 1 pF až 5 pF CMC 0,49 % 70 kHz až 80 kHz 1 pF až 5 pF CMC 0,44 % 80 kHz až 100 kHz 1 pF až 5 pF CMC 0,40 % 100 kHz až 110 kHz 1 pF až 5 pF CMC 0,75 % 110 kHz až 120 kHz 1 pF až 5 pF CMC 0,69 % 120 kHz až 130 kHz 1 pF až 5 pF CMC 0,65 % 130 kHz až 140 kHz 1 pF až 5 pF CMC 0,61 % 140 kHz až 150 kHz 1 pF až 5 pF CMC 0,58 % 150 kHz až 170 kHz 1 pF až 5 pF CMC 0,55 % 170 kHz až 200 kHz 1 pF až 5 pF CMC 0,50 % 200 kHz až 250 kHz 1 pF až 5 pF CMC 0,45 % 250 kHz až 300 kHz 1 pF až 5 pF CMC 0,39 % 300 kHz až 350 kHz 1 pF až 5 pF CMC 0,81 % 350 kHz až 400 kHz 1 pF až 5 pF CMC 0,72 % 400 kHz až 450 kHz 1 pF až 5 pF CMC 0,65 % 450 kHz až 500 kHz 1 pF až 5 pF CMC 0,59 % 500 kHz až 600 kHz 1 pF až 5 pF CMC 0,55 % 600 kHz až 700 kHz 1 pF až 5 pF CMC 0,49 % 700 kHz až 800 kHz 1 pF až 5 pF CMC 0,44 % 800 kHz až 1 MHz 1 pF až 5 pF CMC 0,40 % 1 kHz až 2 kHz 5 pF až 10 pF CMC 4,1 % 2 kHz až 3 kHz 5 pF až 10 pF CMC 2,2 % 3 kHz až 4 kHz 5 pF až 10 pF CMC 1,5 % 4 kHz až 5 kHz 5 pF až 10 pF CMC 1,2 % 5 kHz až 6 kHz 5 pF až 10 pF CMC 0,94 % 6 kHz až 7 kHz 5 pF až 10 pF CMC 0,81 % 7 kHz až 8 kHz 5 pF až 10 pF CMC 0,72 % 8 kHz až 9 kHz 5 pF až 10 pF CMC 0,65 % 9 kHz až 10 kHz 5 pF až 10 pF CMC 0,59 % 10 kHz až 15 kHz 5 pF až 10 pF CMC 0,55 % 15 kHz až 20 kHz 5 pF až 10 pF CMC 0,42 % 20 kHz až 25 kHz 5 pF až 10 pF CMC 0,36 % 25 kHz až 30 kHz 5 pF až 10 pF CMC 0,32 % 30 kHz až 1 MHz 5 pF až 10 pF CMC 0,29 % 500 Hz až 600 Hz 10 pF až 50 pF CMC 4,3 % 600 Hz až 700 Hz 10 pF až 50 pF CMC 3,7 % 700 Hz až 800 Hz 10 pF až 50 pF CMC 3,2 % 800 Hz až 900 Hz 10 pF až 50 pF CMC 2,8 % 900 Hz až 1 kHz 10 pF až 50 pF CMC 2,6 % 1 kHz až 2 kHz 10 pF až 50 pF CMC 2,2 % 2 kHz až 3 kHz 10 pF až 50 pF CMC 1,2 % 3 kHz až 4 kHz 10 pF až 50 pF CMC 0,81 % 4 kHz až 5 kHz 10 pF až 50 pF CMC 0,65 % 5 kHz až 6 kHz 10 pF až 50 pF CMC 0,55 % 6 kHz až 7 kHz 10 pF až 50 pF CMC 0,49 % 7 kHz až 8 kHz 10 pF až 50 pF CMC 0,44 % 8 kHz až 9 kHz 10 pF až 50 pF CMC 0,40 % 9 kHz až 10 kHz 10 pF až 50 pF CMC 0,38 % 10 kHz až 15 kHz 10 pF až 50 pF CMC 0,36 % 15 kHz až 20 kHz 10 pF až 50 pF CMC 0,29 % 20 kHz až 1 MHz 10 pF až 50 pF CMC 0,26 % 100 Hz až 200 Hz 50 pF až 100 pF CMC 4,3 % 200 Hz až 300 Hz 50 pF až 100 pF CMC 2,3 % 300 Hz až 400 Hz 50 pF až 100 pF CMC 1,7 % 400 Hz až 500 Hz 50 pF až 100 pF CMC 1,4 % 500 Hz až 600 Hz 50 pF až 100 pF CMC 1,2 % 600 Hz až 700 Hz 50 pF až 100 pF CMC 0,99 % 700 Hz až 800 Hz 50 pF až 100 pF CMC 0,89 % 800 Hz až 900 Hz 50 pF až 100 pF CMC 0,82 % 900 Hz až 1 kHz 50 pF až 100 pF CMC 0,77 % 1 kHz až 2 kHz 50 pF až 100 pF CMC 0,55 % 2 kHz až 3 kHz 50 pF až 100 pF CMC 0,36 % 3 kHz až 4 kHz 50 pF až 100 pF CMC 0,29 % 4 kHz až 5 kHz 50 pF až 100 pF CMC 0,26 % 5 kHz až 1 MHz 50 pF až 100 pF CMC 0,24 % 50 Hz až 60 Hz 100 pF až 500 pF CMC 9,9 % 60 Hz až 70 Hz 100 pF až 500 pF CMC 7,9 % 70 Hz až 80 Hz 100 pF až 500 pF CMC 6,5 % 80 Hz až 90 Hz 100 pF až 500 pF CMC 5,6 % 90 Hz až 100 Hz 100 pF až 500 pF CMC 4,9 % 100 Hz až 160 Hz 100 pF až 500 pF CMC 2,3 % 160 Hz až 200 Hz 100 pF až 500 pF CMC 1,4 % 200 Hz až 300 Hz 100 pF až 500 pF CMC 1,2 % 300 Hz až 400 Hz 100 pF až 500 pF CMC 0,81 % 400 Hz až 500 Hz 100 pF až 500 pF CMC 0,65 % 500 Hz až 600 Hz 100 pF až 500 pF CMC 0,55 % 600 Hz až 700 Hz 100 pF až 500 pF CMC 0,49 % 700 Hz až 800 Hz 100 pF až 500 pF CMC 0,44 % 800 Hz až 900 Hz 100 pF až 500 pF CMC 0,40 % 900 Hz až 1 kHz 100 pF až 500 pF CMC 0,38 % 1 kHz až 2 kHz 100 pF až 500 pF CMC 0,36 % 2 kHz až 3 kHz 100 pF až 500 pF CMC 0,26 % 3 kHz až 4 kHz 100 pF až 500 pF CMC 0,23 % 4 kHz až 5 kHz 100 pF až 500 pF CMC 0,21 % 5 kHz až 1 MHz 100 pF až 500 pF CMC 0,17 % 50 Hz až 60 Hz 500 pF až 1 nF CMC 2,3 % 60 Hz až 70 Hz 500 pF až 1 nF CMC 1,9 % 70 Hz až 80 Hz 500 pF až 1 nF CMC 1,6 % 80 Hz až 100 Hz 500 pF až 1 nF CMC 1,4 % 100 Hz až 160 Hz 500 pF až 1 nF CMC 0,72 % 160 Hz až 200 Hz 500 pF až 1 nF CMC 0,40 % 200 Hz až 300 Hz 500 pF až 1 nF CMC 0,36 % 300 Hz až 400 Hz 500 pF až 1 nF CMC 0,29 % 400 Hz až 500 Hz 500 pF až 1 nF CMC 0,26 % 500 Hz až 700 Hz 500 pF až 1 nF CMC 0,24 % 700 Hz až 1 kHz 500 pF až 1 nF CMC 0,22 % 1 kHz až 2 kHz 500 pF až 1 nF CMC 0,36 % 2 kHz až 3 kHz 500 pF až 1 nF CMC 0,26 % 3 kHz až 4 kHz 500 pF až 1 nF CMC 0,23 % 4 kHz až 5 kHz 500 pF až 1 nF CMC 0,21 % 5 kHz až 1 MHz 500 pF až 1 nF CMC 0,17 % 20 Hz až 30 Hz 1 nF až 5 nF CMC 3,6 % 30 Hz až 40 Hz 1 nF až 5 nF CMC 2,2 % 40 Hz až 50 Hz 1 nF až 5 nF CMC 1,6 % 50 Hz až 60 Hz 1 nF až 5 nF CMC 1,2 % 60 Hz až 70 Hz 1 nF až 5 nF CMC 0,91 % 70 Hz až 80 Hz 1 nF až 5 nF CMC 0,77 % 80 Hz až 90 Hz 1 nF až 5 nF CMC 0,68 % 90 Hz až 100 Hz 1 nF až 5 nF CMC 0,61 % 100 Hz až 200 Hz 1 nF až 5 nF CMC 0,36 % 200 Hz až 300 Hz 1 nF až 5 nF CMC 0,26 % 300 Hz až 500 Hz 1 nF až 5 nF CMC 0,23 % 500 Hz až 1 MHz 1 nF až 5 nF CMC 0,15 % 20 Hz až 30 Hz 5 nF až 10 nF CMC 0,97 % 30 Hz až 40 Hz 5 nF až 10 nF CMC 0,70 % 40 Hz až 50 Hz 5 nF až 10 nF CMC 0,58 % 50 Hz až 60 Hz 5 nF až 10 nF CMC 0,35 % 60 Hz až 70 Hz 5 nF až 10 nF CMC 0,31 % 70 Hz až 100 Hz 5 nF až 10 nF CMC 0,28 % 100 Hz až 400 Hz 5 nF až 10 nF CMC 0,20 % 400 Hz až 500 Hz 5 nF až 10 nF CMC 0,17 % 500 Hz až 1 MHz 5 nF až 10 nF CMC 0,13 % 20 Hz až 30 Hz 10 nF až 50 nF CMC 0,65 % 30 Hz až 40 Hz 10 nF až 50 nF CMC 0,52 % 40 Hz až 50 Hz 10 nF až 50 nF CMC 0,46 % 50 Hz až 70 Hz 10 nF až 50 nF CMC 0,26 % 70 Hz až 100 Hz 10 nF až 50 nF CMC 0,22 % 100 Hz až 103 kHz 10 nF až 50 nF CMC 0,13 % 103 kHz až 150 kHz 10 nF až 50 nF CMC 0,19 % 150 kHz až 300 kHz 10 nF až 50 nF CMC 0,21 % 300 kHz až 500 kHz 10 nF až 50 nF CMC 0,28 % 500 kHz až 1 MHz 10 nF až 50 nF CMC 0,39 % 20 Hz až 40 Hz 50 nF až 100 nF CMC 0,40 % 40 Hz až 50 Hz 50 nF až 100 nF CMC 0,36 % 50 Hz až 70 Hz 50 nF až 100 nF CMC 0,26 % 70 Hz až 100 Hz 50 nF až 100 nF CMC 0,22 % 100 Hz až 103 kHz 50 nF až 100 nF CMC 0,13 % 103 kHz až 150 kHz 50 nF až 100 nF CMC 0,19 % 150 kHz až 300 kHz 50 nF až 100 nF CMC 0,21 % 300 kHz až 500 kHz 50 nF až 100 nF CMC 0,28 % 500 kHz až 1 MHz 50 nF až 100 nF CMC 0,39 % 20 Hz až 50 Hz 100 nF až 500 nF CMC 0,36 % 50 Hz až 100 Hz 100 nF až 500 nF CMC 0,18 % 100 Hz až 10 kHz 100 nF až 500 nF CMC 0,12 % 10 kHz až 70 kHz 100 nF až 500 nF CMC 0,22 % 70 kHz až 100 kHz 100 nF až 500 nF CMC 0,25 % 100 kHz až 140 kHz 100 nF až 500 nF CMC 0,27 % 140 kHz až 230 kHz 100 nF až 500 nF CMC 0,34 % 230 kHz až 280 kHz 100 nF až 500 nF CMC 0,38 % 280 kHz až 300 kHz 100 nF až 500 nF CMC 0,40 % 300 kHz až 350 kHz 100 nF až 500 nF CMC 0,56 % 350 kHz až 400 kHz 100 nF až 500 nF CMC 0,62 % 400 kHz až 450 kHz 100 nF až 500 nF CMC 0,68 % 450 kHz až 500 kHz 100 nF až 500 nF CMC 0,74 % 500 kHz až 600 kHz 100 nF až 500 nF CMC 0,86 % 600 kHz až 700 kHz 100 nF až 500 nF CMC 0,97 % 700 kHz až 800 kHz 100 nF až 500 nF CMC 1,1 % 800 kHz až 1 MHz 100 nF až 500 nF CMC 1,4 % 20 Hz až 50 Hz 500 nF až 1 µF CMC 0,36 % 50 Hz až 100 Hz 500 nF až 1 µF CMC 0,18 % 100 Hz až 10 kHz 500 nF až 1 µF CMC 0,12 % 10 kHz až 70 kHz 500 nF až 1 µF CMC 0,22 % 70 kHz až 100 kHz 500 nF až 1 µF CMC 0,25 % 100 kHz až 120 kHz 500 nF až 1 µF CMC 0,35 % 120 kHz až 150 kHz 500 nF až 1 µF CMC 0,40 % 150 kHz až 180 kHz 500 nF až 1 µF CMC 0,45 % 180 kHz až 220 kHz 500 nF až 1 µF CMC 0,51 % 220 kHz až 250 kHz 500 nF až 1 µF CMC 0,56 % 250 kHz až 300 kHz 500 nF až 1 µF CMC 0,64 % 300 kHz až 350 kHz 500 nF až 1 µF CMC 0,97 % 350 kHz až 400 kHz 500 nF až 1 µF CMC 1,1 % 400 kHz až 500 kHz 500 nF až 1 µF CMC 1,4 % 500 kHz až 600 kHz 500 nF až 1 µF CMC 1,6 % 600 kHz až 700 kHz 500 nF až 1 µF CMC 1,8 % 700 kHz až 1 MHz 500 nF až 1 µF CMC 2,5 % 20 Hz až 50 Hz 1 µF až 5 µF CMC 0,34 % 50 Hz až 5 kHz 1 µF až 5 µF CMC 0,20 % 5 kHz až 10 kHz 1 µF až 5 µF CMC 0,25 % 10 kHz až 15 kHz 1 µF až 5 µF CMC 0,29 % 15 kHz až 20 kHz 1 µF až 5 µF CMC 0,33 % 20 kHz až 25 kHz 1 µF až 5 µF CMC 0,38 % 25 kHz až 30 kHz 1 µF až 5 µF CMC 0,42 % 30 kHz až 40 kHz 1 µF až 5 µF CMC 0,33 % 40 kHz až 50 kHz 1 µF až 5 µF CMC 0,38 % 50 kHz až 60 kHz 1 µF až 5 µF CMC 0,42 % 60 kHz až 70 kHz 1 µF až 5 µF CMC 0,46 % 70 kHz až 80 kHz 1 µF až 5 µF CMC 0,51 % 80 kHz až 90 kHz 1 µF až 5 µF CMC 0,55 % 90 kHz až 100 kHz 1 µF až 5 µF CMC 0,59 % 100 kHz až 110 kHz 1 µF až 5 µF CMC 1,1 % 110 kHz až 140 kHz 1 µF až 5 µF CMC 1,3 % 140 kHz až 160 kHz 1 µF až 5 µF CMC 1,5 % 160 kHz až 190 kHz 1 µF až 5 µF CMC 1,7 % 190 kHz až 210 kHz 1 µF až 5 µF CMC 1,9 % 210 kHz až 250 kHz 1 µF až 5 µF CMC 2,2 % 250 kHz až 300 kHz 1 µF až 5 µF CMC 2,6 % 300 kHz až 350 kHz 1 µF až 5 µF CMC 4,3 % 350 kHz až 400 kHz 1 µF až 5 µF CMC 4,9 % 400 kHz až 450 kHz 1 µF až 5 µF CMC 5,4 % 450 kHz až 500 kHz 1 µF až 5 µF CMC 6,0 % 20 Hz až 50 Hz 5 µF až 10 µF CMC 0,34 % 50 Hz až 5 kHz 5 µF až 10 µF CMC 0,20 % 5 kHz až 10 kHz 5 µF až 10 µF CMC 0,25 % 10 kHz až 15 kHz 5 µF až 10 µF CMC 0,29 % 15 kHz až 20 kHz 5 µF až 10 µF CMC 0,33 % 20 kHz až 25 kHz 5 µF až 10 µF CMC 0,38 % 25 kHz až 30 kHz 5 µF až 10 µF CMC 0,42 % 30 kHz až 40 kHz 5 µF až 10 µF CMC 0,51 % 40 kHz až 50 kHz 5 µF až 10 µF CMC 0,59 % 50 kHz až 60 kHz 5 µF až 10 µF CMC 0,68 % 60 kHz až 70 kHz 5 µF až 10 µF CMC 0,77 % 70 kHz až 80 kHz 5 µF až 10 µF CMC 0,85 % 80 kHz až 90 kHz 5 µF až 10 µF CMC 0,94 % 90 kHz až 100 kHz 5 µF až 10 µF CMC 1,1 % 100 kHz až 110 kHz 5 µF až 10 µF CMC 2,0 % 110 kHz až 140 kHz 5 µF až 10 µF CMC 2,4 % 140 kHz až 160 kHz 5 µF až 10 µF CMC 2,8 % 160 kHz až 190 kHz 5 µF až 10 µF CMC 3,2 % 190 kHz až 210 kHz 5 µF až 10 µF CMC 3,6 % 210 kHz až 250 kHz 5 µF až 10 µF CMC 4,2 % 250 kHz až 300 kHz 5 µF až 10 µF CMC 5,0 % 20 Hz až 50 Hz 10 µF až 20 µF CMC 0,34 % 50 Hz až 500 Hz 10 µF až 20 µF CMC 0,20 % 500 Hz až 700 Hz 10 µF až 20 µF CMC 0,22 % 700 Hz až 1 kHz 10 µF až 20 µF CMC 0,25 % 1 kHz až 2 kHz 10 µF až 20 µF CMC 0,33 % 2 kHz až 3 kHz 10 µF až 20 µF CMC 0,42 % 3 kHz až 4 kHz 10 µF až 20 µF CMC 0,51 % 4 kHz až 5 kHz 10 µF až 20 µF CMC 0,59 % 5 kHz až 6 kHz 10 µF až 20 µF CMC 0,68 % 6 kHz až 7 kHz 10 µF až 20 µF CMC 0,77 % 7 kHz až 8 kHz 10 µF až 20 µF CMC 0,85 % 8 kHz až 9 kHz 10 µF až 20 µF CMC 0,94 % 9 kHz až 10 kHz 10 µF až 20 µF CMC 1,1 % 10 kHz až 15 kHz 10 µF až 20 µF CMC 1,5 % 15 kHz až 20 kHz 10 µF až 20 µF CMC 1,9 % 20 kHz až 25 kHz 10 µF až 20 µF CMC 2,4 % 25 kHz až 30 kHz 10 µF až 20 µF CMC 2,8 % 30 kHz až 40 kHz 10 µF až 20 µF CMC 1,9 % 40 kHz až 50 kHz 10 µF až 20 µF CMC 2,4 % 50 kHz až 60 kHz 10 µF až 20 µF CMC 2,8 % 60 kHz až 70 kHz 10 µF až 20 µF CMC 3,2 % 70 kHz až 80 kHz 10 µF až 20 µF CMC 3,7 % 80 kHz až 90 kHz 10 µF až 20 µF CMC 4,1 % 90 kHz až 100 kHz 10 µF až 20 µF CMC 4,6 % 20 Hz až 50 Hz 20 µF až 50 µF CMC 0,34 % 50 Hz až 500 Hz 20 µF až 50 µF CMC 0,20 % 500 Hz až 700 Hz 20 µF až 50 µF CMC 0,22 % 700 Hz až 1 kHz 20 µF až 50 µF CMC 0,25 % 1 kHz až 2 kHz 20 µF až 50 µF CMC 0,33 % 2 kHz až 3 kHz 20 µF až 50 µF CMC 0,42 % 3 kHz až 4 kHz 20 µF až 50 µF CMC 0,51 % 4 kHz až 5 kHz 20 µF až 50 µF CMC 0,59 % 5 kHz až 6 kHz 20 µF až 50 µF CMC 0,68 % 6 kHz až 7 kHz 20 µF až 50 µF CMC 0,77 % 7 kHz až 8 kHz 20 µF až 50 µF CMC 0,85 % 8 kHz až 9 kHz 20 µF až 50 µF CMC 0,94 % 9 kHz až 10 kHz 20 µF až 50 µF CMC 1,1 % 10 kHz až 15 kHz 20 µF až 50 µF CMC 1,5 % 15 kHz až 20 kHz 20 µF až 50 µF CMC 1,9 % 20 kHz až 25 kHz 20 µF až 50 µF CMC 2,4 % 25 kHz až 30 kHz 20 µF až 50 µF CMC 2,8 % 30 kHz až 40 kHz 20 µF až 50 µF CMC 1,9 % 40 kHz až 50 kHz 20 µF až 50 µF CMC 2,4 % 20 Hz až 50 Hz 50 µF až 100 µF CMC 0,34 % 50 Hz až 500 Hz 50 µF až 100 µF CMC 0,20 % 500 Hz až 700 Hz 50 µF až 100 µF CMC 0,22 % 700 Hz až 1 kHz 50 µF až 100 µF CMC 0,25 % 1 kHz až 2 kHz 50 µF až 100 µF CMC 0,33 % 2 kHz až 3 kHz 50 µF až 100 µF CMC 0,42 % 3 kHz až 4 kHz 50 µF až 100 µF CMC 0,51 % 4 kHz až 5 kHz 50 µF až 100 µF CMC 0,59 % 5 kHz až 6 kHz 50 µF až 100 µF CMC 0,68 % 6 kHz až 7 kHz 50 µF až 100 µF CMC 0,77 % 7 kHz až 8 kHz 50 µF až 100 µF CMC 0,85 % 8 kHz až 9 kHz 50 µF až 100 µF CMC 0,94 % 9 kHz až 10 kHz 50 µF až 100 µF CMC 1,1 % 10 kHz až 15 kHz 50 µF až 100 µF CMC 1,5 % 15 kHz až 20 kHz 50 µF až 100 µF CMC 1,9 % 20 Hz až 50 Hz 100 µF až 500 µF CMC 0,44 % 50 Hz až 70 Hz 100 µF až 500 µF CMC 0,29 % 70 Hz až 200 Hz 100 µF až 500 µF CMC 0,33 % 200 Hz až 300 Hz 100 µF až 500 µF CMC 0,42 % 300 Hz až 400 Hz 100 µF až 500 µF CMC 0,51 % 400 Hz až 500 Hz 100 µF až 500 µF CMC 0,59 % 500 Hz až 600 Hz 100 µF až 500 µF CMC 0,68 % 600 Hz až 700 Hz 100 µF až 500 µF CMC 0,77 % 700 Hz až 800 Hz 100 µF až 500 µF CMC 0,85 % 800 Hz až 900 Hz 100 µF až 500 µF CMC 0,94 % 900 Hz až 2 kHz 100 µF až 500 µF CMC 1,1 % 2 kHz až 3 kHz 100 µF až 500 µF CMC 1,5 % 3 kHz až 4 kHz 100 µF až 500 µF CMC 1,9 % 4 kHz až 5 kHz 100 µF až 500 µF CMC 2,4 % 20 Hz až 50 Hz 500 µF až 1 mF CMC 0,44 % 50 Hz až 70 Hz 500 µF až 1 mF CMC 0,29 % 70 Hz až 200 Hz 500 µF až 1 mF CMC 0,33 % 200 Hz až 300 Hz 500 µF až 1 mF CMC 0,42 % 300 Hz až 400 Hz 500 µF až 1 mF CMC 0,51 % 400 Hz až 500 Hz 500 µF až 1 mF CMC 0,59 % 500 Hz až 600 Hz 500 µF až 1 mF CMC 0,68 % 600 Hz až 700 Hz 500 µF až 1 mF CMC 0,77 % 700 Hz až 800 Hz 500 µF až 1 mF CMC 0,85 % 800 Hz až 900 Hz 500 µF až 1 mF CMC 0,94 % 900 Hz až 1 kHz 500 µF až 1 mF CMC 1,1 % 1 kHz až 2 kHz 500 µF až 1 mF CMC 1,9 % 20 Hz až 30 Hz 1 mF až 5 mF CMC 0,70 % 30 Hz až 40 Hz 1 mF až 5 mF CMC 0,78 % 40 Hz až 80 Hz 1 mF až 5 mF CMC 0,89 % 80 Hz až 90 Hz 1 mF až 5 mF CMC 0,96 % 90 Hz až 160 Hz 1 mF až 5 mF CMC 1,1 % 160 Hz až 300 Hz 1 mF až 5 mF CMC 1,7 % 300 Hz až 400 Hz 1 mF až 5 mF CMC 2,1 % 400 Hz až 500 Hz 1 mF až 5 mF CMC 2,6 % 500 Hz až 600 Hz 1 mF až 5 mF CMC 3,0 % 600 Hz až 700 Hz 1 mF až 5 mF CMC 3,4 % 700 Hz až 800 Hz 1 mF až 5 mF CMC 3,9 % 800 Hz až 900 Hz 1 mF až 5 mF CMC 4,3 % 900 Hz až 1 kHz 1 mF až 5 mF CMC 4,7 % 50 Hz až 60 Hz 5 mF až 10 mF CMC 1,4 % 60 Hz až 160 Hz 5 mF až 10 mF CMC 1,9 % 160 Hz až 220 Hz 5 mF až 10 mF CMC 2,3 % 220 Hz až 300 Hz 5 mF až 10 mF CMC 3,0 % TP7, TP24 Pojemnosc / Wzorce pojemnosci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem RLC 10 kHz do 15 kHz od 1 pF do 5 pF CMC 2,2 % 15 kHz do 20 kHz od 1 pF do 5 pF CMC 1,5 % 20 kHz do 25 kHz od 1 pF do 5 pF CMC 1,2 % 25 kHz do 30 kHz od 1 pF do 5 pF CMC 0,94 % 30 kHz do 40 kHz od 1 pF do 5 pF CMC 0,81 % 40 kHz do 50 kHz od 1 pF do 5 pF CMC 0,65 % 50 kHz do 60 kHz od 1 pF do 5 pF CMC 0,55 % 60 kHz do 70 kHz od 1 pF do 5 pF CMC 0,49 % 70 kHz do 80 kHz od 1 pF do 5 pF CMC 0,44 % 80 kHz do 100 kHz od 1 pF do 5 pF CMC 0,40 % 100 kHz do 110 kHz od 1 pF do 5 pF CMC 0,75 % 110 kHz do 120 kHz od 1 pF do 5 pF CMC 0,69 % 120 kHz do 130 kHz od 1 pF do 5 pF CMC 0,65 % 130 kHz do 140 kHz od 1 pF do 5 pF CMC 0,61 % 140 kHz do 150 kHz od 1 pF do 5 pF CMC 0,58 % 150 kHz do 170 kHz od 1 pF do 5 pF CMC 0,55 % 170 kHz do 200 kHz od 1 pF do 5 pF CMC 0,50 % 200 kHz do 250 kHz od 1 pF do 5 pF CMC 0,45 % 250 kHz do 300 kHz od 1 pF do 5 pF CMC 0,39 % 300 kHz do 350 kHz od 1 pF do 5 pF CMC 0,81 % 350 kHz do 400 kHz od 1 pF do 5 pF CMC 0,72 % 400 kHz do 450 kHz od 1 pF do 5 pF CMC 0,65 % 450 kHz do 500 kHz od 1 pF do 5 pF CMC 0,59 % 500 kHz do 600 kHz od 1 pF do 5 pF CMC 0,55 % 600 kHz do 700 kHz od 1 pF do 5 pF CMC 0,49 % 700 kHz do 800 kHz od 1 pF do 5 pF CMC 0,44 % 800 kHz do 1 MHz od 1 pF do 5 pF CMC 0,40 % 1 kHz do 2 kHz od 5 pF do 10 pF CMC 4,1 % 2 kHz do 3 kHz od 5 pF do 10 pF CMC 2,2 % 3 kHz do 4 kHz od 5 pF do 10 pF CMC 1,5 % 4 kHz do 5 kHz od 5 pF do 10 pF CMC 1,2 % 5 kHz do 6 kHz od 5 pF do 10 pF CMC 0,94 % 6 kHz do 7 kHz od 5 pF do 10 pF CMC 0,81 % 7 kHz do 8 kHz od 5 pF do 10 pF CMC 0,72 % 8 kHz do 9 kHz od 5 pF do 10 pF CMC 0,65 % 9 kHz do 10 kHz od 5 pF do 10 pF CMC 0,59 % 10 kHz do 15 kHz od 5 pF do 10 pF CMC 0,55 % 15 kHz do 20 kHz od 5 pF do 10 pF CMC 0,42 % 20 kHz do 25 kHz od 5 pF do 10 pF CMC 0,36 % 25 kHz do 30 kHz od 5 pF do 10 pF CMC 0,32 % 30 kHz do 1 MHz od 5 pF do 10 pF CMC 0,29 % 500 Hz do 600 Hz od 10 pF do 50 pF CMC 4,3 % 600 Hz do 700 Hz od 10 pF do 50 pF CMC 3,7 % 700 Hz do 800 Hz od 10 pF do 50 pF CMC 3,2 % 800 Hz do 900 Hz od 10 pF do 50 pF CMC 2,8 % 900 Hz do 1 kHz od 10 pF do 50 pF CMC 2,6 % 1 kHz do 2 kHz od 10 pF do 50 pF CMC 2,2 % 2 kHz do 3 kHz od 10 pF do 50 pF CMC 1,2 % 3 kHz do 4 kHz od 10 pF do 50 pF CMC 0,81 % 4 kHz do 5 kHz od 10 pF do 50 pF CMC 0,65 % 5 kHz do 6 kHz od 10 pF do 50 pF CMC 0,55 % 6 kHz do 7 kHz od 10 pF do 50 pF CMC 0,49 % 7 kHz do 8 kHz od 10 pF do 50 pF CMC 0,44 % 8 kHz do 9 kHz od 10 pF do 50 pF CMC 0,40 % 9 kHz do 10 kHz od 10 pF do 50 pF CMC 0,38 % 10 kHz do 15 kHz od 10 pF do 50 pF CMC 0,36 % 15 kHz do 20 kHz od 10 pF do 50 pF CMC 0,29 % 20 kHz do 1 MHz od 10 pF do 50 pF CMC 0,26 % 100 Hz do 200 Hz od 50 pF do 100 pF CMC 4,3 % 200 Hz do 300 Hz od 50 pF do 100 pF CMC 2,3 % 300 Hz do 400 Hz od 50 pF do 100 pF CMC 1,7 % 400 Hz do 500 Hz od 50 pF do 100 pF CMC 1,4 % 500 Hz do 600 Hz od 50 pF do 100 pF CMC 1,2 % 600 Hz do 700 Hz od 50 pF do 100 pF CMC 0,99 % 700 Hz do 800 Hz od 50 pF do 100 pF CMC 0,89 % 800 Hz do 900 Hz od 50 pF do 100 pF CMC 0,82 % 900 Hz do 1 kHz od 50 pF do 100 pF CMC 0,77 % 1 kHz do 2 kHz od 50 pF do 100 pF CMC 0,55 % 2 kHz do 3 kHz od 50 pF do 100 pF CMC 0,36 % 3 kHz do 4 kHz od 50 pF do 100 pF CMC 0,29 % 4 kHz do 5 kHz od 50 pF do 100 pF CMC 0,26 % 5 kHz do 1 MHz od 50 pF do 100 pF CMC 0,24 % 50 Hz do 60 Hz od 100 pF do 500 pF CMC 9,9 % 60 Hz do 70 Hz od 100 pF do 500 pF CMC 7,9 % 70 Hz do 80 Hz od 100 pF do 500 pF CMC 6,5 % 80 Hz do 90 Hz od 100 pF do 500 pF CMC 5,6 % 90 Hz do 100 Hz od 100 pF do 500 pF CMC 4,9 % 100 Hz do 160 Hz od 100 pF do 500 pF CMC 2,3 % 160 Hz do 200 Hz od 100 pF do 500 pF CMC 1,4 % 200 Hz do 300 Hz od 100 pF do 500 pF CMC 1,2 % 300 Hz do 400 Hz od 100 pF do 500 pF CMC 0,81 % 400 Hz do 500 Hz od 100 pF do 500 pF CMC 0,65 % 500 Hz do 600 Hz od 100 pF do 500 pF CMC 0,55 % 600 Hz do 700 Hz od 100 pF do 500 pF CMC 0,49 % 700 Hz do 800 Hz od 100 pF do 500 pF CMC 0,44 % 800 Hz do 900 Hz od 100 pF do 500 pF CMC 0,40 % 900 Hz do 1 kHz od 100 pF do 500 pF CMC 0,38 % 1 kHz do 2 kHz od 100 pF do 500 pF CMC 0,36 % 2 kHz do 3 kHz od 100 pF do 500 pF CMC 0,26 % 3 kHz do 4 kHz od 100 pF do 500 pF CMC 0,23 % 4 kHz do 5 kHz od 100 pF do 500 pF CMC 0,21 % 5 kHz do 1 MHz od 100 pF do 500 pF CMC 0,17 % 50 Hz do 60 Hz od 500 pF do 1 nF CMC 2,3 % 60 Hz do 70 Hz od 500 pF do 1 nF CMC 1,9 % 70 Hz do 80 Hz od 500 pF do 1 nF CMC 1,6 % 80 Hz do 100 Hz od 500 pF do 1 nF CMC 1,4 % 100 Hz do 160 Hz od 500 pF do 1 nF CMC 0,72 % 160 Hz do 200 Hz od 500 pF do 1 nF CMC 0,40 % 200 Hz do 300 Hz od 500 pF do 1 nF CMC 0,36 % 300 Hz do 400 Hz od 500 pF do 1 nF CMC 0,29 % 400 Hz do 500 Hz od 500 pF do 1 nF CMC 0,26 % 500 Hz do 700 Hz od 500 pF do 1 nF CMC 0,24 % 700 Hz do 1 kHz od 500 pF do 1 nF CMC 0,22 % 1 kHz do 2 kHz od 500 pF do 1 nF CMC 0,36 % 2 kHz do 3 kHz od 500 pF do 1 nF CMC 0,26 % 3 kHz do 4 kHz od 500 pF do 1 nF CMC 0,23 % 4 kHz do 5 kHz od 500 pF do 1 nF CMC 0,21 % 5 kHz do 1 MHz od 500 pF do 1 nF CMC 0,17 % 20 Hz do 30 Hz od 1 nF do 5 nF CMC 3,6 % 30 Hz do 40 Hz od 1 nF do 5 nF CMC 2,2 % 40 Hz do 50 Hz od 1 nF do 5 nF CMC 1,6 % 50 Hz do 60 Hz od 1 nF do 5 nF CMC 1,2 % 60 Hz do 70 Hz od 1 nF do 5 nF CMC 0,91 % 70 Hz do 80 Hz od 1 nF do 5 nF CMC 0,77 % 80 Hz do 90 Hz od 1 nF do 5 nF CMC 0,68 % 90 Hz do 100 Hz od 1 nF do 5 nF CMC 0,61 % 100 Hz do 200 Hz od 1 nF do 5 nF CMC 0,36 % 200 Hz do 300 Hz od 1 nF do 5 nF CMC 0,26 % 300 Hz do 500 Hz od 1 nF do 5 nF CMC 0,23 % 500 Hz do 1 MHz od 1 nF do 5 nF CMC 0,15 % 20 Hz do 30 Hz od 5 nF do 10 nF CMC 0,97 % 30 Hz do 40 Hz od 5 nF do 10 nF CMC 0,70 % 40 Hz do 50 Hz od 5 nF do 10 nF CMC 0,58 % 50 Hz do 60 Hz od 5 nF do 10 nF CMC 0,35 % 60 Hz do 70 Hz od 5 nF do 10 nF CMC 0,31 % 70 Hz do 100 Hz od 5 nF do 10 nF CMC 0,28 % 100 Hz do 400 Hz od 5 nF do 10 nF CMC 0,20 % 400 Hz do 500 Hz od 5 nF do 10 nF CMC 0,17 % 500 Hz do 1 MHz od 5 nF do 10 nF CMC 0,13 % 20 Hz do 30 Hz od 10 nF do 50 nF CMC 0,65 % 30 Hz do 40 Hz od 10 nF do 50 nF CMC 0,52 % 40 Hz do 50 Hz od 10 nF do 50 nF CMC 0,46 % 50 Hz do 70 Hz od 10 nF do 50 nF CMC 0,26 % 70 Hz do 100 Hz od 10 nF do 50 nF CMC 0,22 % 100 Hz do 103 kHz od 10 nF do 50 nF CMC 0,13 % 103 kHz do 150 kHz od 10 nF do 50 nF CMC 0,19 % 150 kHz do 300 kHz od 10 nF do 50 nF CMC 0,21 % 300 kHz do 500 kHz od 10 nF do 50 nF CMC 0,28 % 500 kHz do 1 MHz od 10 nF do 50 nF CMC 0,39 % 20 Hz do 40 Hz od 50 nF do 100 nF CMC 0,40 % 40 Hz do 50 Hz od 50 nF do 100 nF CMC 0,36 % 50 Hz do 70 Hz od 50 nF do 100 nF CMC 0,26 % 70 Hz do 100 Hz od 50 nF do 100 nF CMC 0,22 % 100 Hz do 103 kHz od 50 nF do 100 nF CMC 0,13 % 103 kHz do 150 kHz od 50 nF do 100 nF CMC 0,19 % 150 kHz do 300 kHz od 50 nF do 100 nF CMC 0,21 % 300 kHz do 500 kHz od 50 nF do 100 nF CMC 0,28 % 500 kHz do 1 MHz od 50 nF do 100 nF CMC 0,39 % 20 Hz do 50 Hz od 100 nF do 500 nF CMC 0,36 % 50 Hz do 100 Hz od 100 nF do 500 nF CMC 0,18 % 100 Hz do 10 kHz od 100 nF do 500 nF CMC 0,12 % 10 kHz do 70 kHz od 100 nF do 500 nF CMC 0,22 % 70 kHz do 100 kHz od 100 nF do 500 nF CMC 0,25 % 100 kHz do 140 kHz od 100 nF do 500 nF CMC 0,27 % 140 kHz do 230 kHz od 100 nF do 500 nF CMC 0,34 % 230 kHz do 280 kHz od 100 nF do 500 nF CMC 0,38 % 280 kHz do 300 kHz od 100 nF do 500 nF CMC 0,40 % 300 kHz do 350 kHz od 100 nF do 500 nF CMC 0,56 % 350 kHz do 400 kHz od 100 nF do 500 nF CMC 0,62 % 400 kHz do 450 kHz od 100 nF do 500 nF CMC 0,68 % 450 kHz do 500 kHz od 100 nF do 500 nF CMC 0,74 % 500 kHz do 600 kHz od 100 nF do 500 nF CMC 0,86 % 600 kHz do 700 kHz od 100 nF do 500 nF CMC 0,97 % 700 kHz do 800 kHz od 100 nF do 500 nF CMC 1,1 % 800 kHz do 1 MHz od 100 nF do 500 nF CMC 1,4 % 20 Hz do 50 Hz od 500 nF do 1 µF CMC 0,36 % 50 Hz do 100 Hz od 500 nF do 1 µF CMC 0,18 % 100 Hz do 10 kHz od 500 nF do 1 µF CMC 0,12 % 10 kHz do 70 kHz od 500 nF do 1 µF CMC 0,22 % 70 kHz do 100 kHz od 500 nF do 1 µF CMC 0,25 % 100 kHz do 120 kHz od 500 nF do 1 µF CMC 0,35 % 120 kHz do 150 kHz od 500 nF do 1 µF CMC 0,40 % 150 kHz do 180 kHz od 500 nF do 1 µF CMC 0,45 % 180 kHz do 220 kHz od 500 nF do 1 µF CMC 0,51 % 220 kHz do 250 kHz od 500 nF do 1 µF CMC 0,56 % 250 kHz do 300 kHz od 500 nF do 1 µF CMC 0,64 % 300 kHz do 350 kHz od 500 nF do 1 µF CMC 0,97 % 350 kHz do 400 kHz od 500 nF do 1 µF CMC 1,1 % 400 kHz do 500 kHz od 500 nF do 1 µF CMC 1,4 % 500 kHz do 600 kHz od 500 nF do 1 µF CMC 1,6 % 600 kHz do 700 kHz od 500 nF do 1 µF CMC 1,8 % 700 kHz do 1 MHz od 500 nF do 1 µF CMC 2,5 % 20 Hz do 50 Hz od 1 µF do 5 µF CMC 0,34 % 50 Hz do 5 kHz od 1 µF do 5 µF CMC 0,20 % 5 kHz do 10 kHz od 1 µF do 5 µF CMC 0,25 % 10 kHz do 15 kHz od 1 µF do 5 µF CMC 0,29 % 15 kHz do 20 kHz od 1 µF do 5 µF CMC 0,33 % 20 kHz do 25 kHz od 1 µF do 5 µF CMC 0,38 % 25 kHz do 30 kHz od 1 µF do 5 µF CMC 0,42 % 30 kHz do 40 kHz od 1 µF do 5 µF CMC 0,33 % 40 kHz do 50 kHz od 1 µF do 5 µF CMC 0,38 % 50 kHz do 60 kHz od 1 µF do 5 µF CMC 0,42 % 60 kHz do 70 kHz od 1 µF do 5 µF CMC 0,46 % 70 kHz do 80 kHz od 1 µF do 5 µF CMC 0,51 % 80 kHz do 90 kHz od 1 µF do 5 µF CMC 0,55 % 90 kHz do 100 kHz od 1 µF do 5 µF CMC 0,59 % 100 kHz do 110 kHz od 1 µF do 5 µF CMC 1,1 % 110 kHz do 140 kHz od 1 µF do 5 µF CMC 1,3 % 140 kHz do 160 kHz od 1 µF do 5 µF CMC 1,5 % 160 kHz do 190 kHz od 1 µF do 5 µF CMC 1,7 % 190 kHz do 210 kHz od 1 µF do 5 µF CMC 1,9 % 210 kHz do 250 kHz od 1 µF do 5 µF CMC 2,2 % 250 kHz do 300 kHz od 1 µF do 5 µF CMC 2,6 % 300 kHz do 350 kHz od 1 µF do 5 µF CMC 4,3 % 350 kHz do 400 kHz od 1 µF do 5 µF CMC 4,9 % 400 kHz do 450 kHz od 1 µF do 5 µF CMC 5,4 % 450 kHz do 500 kHz od 1 µF do 5 µF CMC 6,0 % 20 Hz do 50 Hz od 5 µF do 10 µF CMC 0,34 % 50 Hz do 5 kHz od 5 µF do 10 µF CMC 0,20 % 5 kHz do 10 kHz od 5 µF do 10 µF CMC 0,25 % 10 kHz do 15 kHz od 5 µF do 10 µF CMC 0,29 % 15 kHz do 20 kHz od 5 µF do 10 µF CMC 0,33 % 20 kHz do 25 kHz od 5 µF do 10 µF CMC 0,38 % 25 kHz do 30 kHz od 5 µF do 10 µF CMC 0,42 % 30 kHz do 40 kHz od 5 µF do 10 µF CMC 0,51 % 40 kHz do 50 kHz od 5 µF do 10 µF CMC 0,59 % 50 kHz do 60 kHz od 5 µF do 10 µF CMC 0,68 % 60 kHz do 70 kHz od 5 µF do 10 µF CMC 0,77 % 70 kHz do 80 kHz od 5 µF do 10 µF CMC 0,85 % 80 kHz do 90 kHz od 5 µF do 10 µF CMC 0,94 % 90 kHz do 100 kHz od 5 µF do 10 µF CMC 1,1 % 100 kHz do 110 kHz od 5 µF do 10 µF CMC 2,0 % 110 kHz do 140 kHz od 5 µF do 10 µF CMC 2,4 % 140 kHz do 160 kHz od 5 µF do 10 µF CMC 2,8 % 160 kHz do 190 kHz od 5 µF do 10 µF CMC 3,2 % 190 kHz do 210 kHz od 5 µF do 10 µF CMC 3,6 % 210 kHz do 250 kHz od 5 µF do 10 µF CMC 4,2 % 250 kHz do 300 kHz od 5 µF do 10 µF CMC 5,0 % 20 Hz do 50 Hz od 10 µF do 20 µF CMC 0,34 % 50 Hz do 500 Hz od 10 µF do 20 µF CMC 0,20 % 500 Hz do 700 Hz od 10 µF do 20 µF CMC 0,22 % 700 Hz do 1 kHz od 10 µF do 20 µF CMC 0,25 % 1 kHz do 2 kHz od 10 µF do 20 µF CMC 0,33 % 2 kHz do 3 kHz od 10 µF do 20 µF CMC 0,42 % 3 kHz do 4 kHz od 10 µF do 20 µF CMC 0,51 % 4 kHz do 5 kHz od 10 µF do 20 µF CMC 0,59 % 5 kHz do 6 kHz od 10 µF do 20 µF CMC 0,68 % 6 kHz do 7 kHz od 10 µF do 20 µF CMC 0,77 % 7 kHz do 8 kHz od 10 µF do 20 µF CMC 0,85 % 8 kHz do 9 kHz od 10 µF do 20 µF CMC 0,94 % 9 kHz do 10 kHz od 10 µF do 20 µF CMC 1,1 % 10 kHz do 15 kHz od 10 µF do 20 µF CMC 1,5 % 15 kHz do 20 kHz od 10 µF do 20 µF CMC 1,9 % 20 kHz do 25 kHz od 10 µF do 20 µF CMC 2,4 % 25 kHz do 30 kHz od 10 µF do 20 µF CMC 2,8 % 30 kHz do 40 kHz od 10 µF do 20 µF CMC 1,9 % 40 kHz do 50 kHz od 10 µF do 20 µF CMC 2,4 % 50 kHz do 60 kHz od 10 µF do 20 µF CMC 2,8 % 60 kHz do 70 kHz od 10 µF do 20 µF CMC 3,2 % 70 kHz do 80 kHz od 10 µF do 20 µF CMC 3,7 % 80 kHz do 90 kHz od 10 µF do 20 µF CMC 4,1 % 90 kHz do 100 kHz od 10 µF do 20 µF CMC 4,6 % 20 Hz do 50 Hz od 20 µF do 50 µF CMC 0,34 % 50 Hz do 500 Hz od 20 µF do 50 µF CMC 0,20 % 500 Hz do 700 Hz od 20 µF do 50 µF CMC 0,22 % 700 Hz do 1 kHz od 20 µF do 50 µF CMC 0,25 % 1 kHz do 2 kHz od 20 µF do 50 µF CMC 0,33 % 2 kHz do 3 kHz od 20 µF do 50 µF CMC 0,42 % 3 kHz do 4 kHz od 20 µF do 50 µF CMC 0,51 % 4 kHz do 5 kHz od 20 µF do 50 µF CMC 0,59 % 5 kHz do 6 kHz od 20 µF do 50 µF CMC 0,68 % 6 kHz do 7 kHz od 20 µF do 50 µF CMC 0,77 % 7 kHz do 8 kHz od 20 µF do 50 µF CMC 0,85 % 8 kHz do 9 kHz od 20 µF do 50 µF CMC 0,94 % 9 kHz do 10 kHz od 20 µF do 50 µF CMC 1,1 % 10 kHz do 15 kHz od 20 µF do 50 µF CMC 1,5 % 15 kHz do 20 kHz od 20 µF do 50 µF CMC 1,9 % 20 kHz do 25 kHz od 20 µF do 50 µF CMC 2,4 % 25 kHz do 30 kHz od 20 µF do 50 µF CMC 2,8 % 30 kHz do 40 kHz od 20 µF do 50 µF CMC 1,9 % 40 kHz do 50 kHz od 20 µF do 50 µF CMC 2,4 % 20 Hz do 50 Hz od 50 µF do 100 µF CMC 0,34 % 50 Hz do 500 Hz od 50 µF do 100 µF CMC 0,20 % 500 Hz do 700 Hz od 50 µF do 100 µF CMC 0,22 % 700 Hz do 1 kHz od 50 µF do 100 µF CMC 0,25 % 1 kHz do 2 kHz od 50 µF do 100 µF CMC 0,33 % 2 kHz do 3 kHz od 50 µF do 100 µF CMC 0,42 % 3 kHz do 4 kHz od 50 µF do 100 µF CMC 0,51 % 4 kHz do 5 kHz od 50 µF do 100 µF CMC 0,59 % 5 kHz do 6 kHz od 50 µF do 100 µF CMC 0,68 % 6 kHz do 7 kHz od 50 µF do 100 µF CMC 0,77 % 7 kHz do 8 kHz od 50 µF do 100 µF CMC 0,85 % 8 kHz do 9 kHz od 50 µF do 100 µF CMC 0,94 % 9 kHz do 10 kHz od 50 µF do 100 µF CMC 1,1 % 10 kHz do 15 kHz od 50 µF do 100 µF CMC 1,5 % 15 kHz do 20 kHz od 50 µF do 100 µF CMC 1,9 % 20 Hz do 50 Hz od 100 µF do 500 µF CMC 0,44 % 50 Hz do 70 Hz od 100 µF do 500 µF CMC 0,29 % 70 Hz do 200 Hz od 100 µF do 500 µF CMC 0,33 % 200 Hz do 300 Hz od 100 µF do 500 µF CMC 0,42 % 300 Hz do 400 Hz od 100 µF do 500 µF CMC 0,51 % 400 Hz do 500 Hz od 100 µF do 500 µF CMC 0,59 % 500 Hz do 600 Hz od 100 µF do 500 µF CMC 0,68 % 600 Hz do 700 Hz od 100 µF do 500 µF CMC 0,77 % 700 Hz do 800 Hz od 100 µF do 500 µF CMC 0,85 % 800 Hz do 900 Hz od 100 µF do 500 µF CMC 0,94 % 900 Hz do 2 kHz od 100 µF do 500 µF CMC 1,1 % 2 kHz do 3 kHz od 100 µF do 500 µF CMC 1,5 % 3 kHz do 4 kHz od 100 µF do 500 µF CMC 1,9 % 4 kHz do 5 kHz od 100 µF do 500 µF CMC 2,4 % 20 Hz do 50 Hz od 500 µF do 1 mF CMC 0,44 % 50 Hz do 70 Hz od 500 µF do 1 mF CMC 0,29 % 70 Hz do 200 Hz od 500 µF do 1 mF CMC 0,33 % 200 Hz do 300 Hz od 500 µF do 1 mF CMC 0,42 % 300 Hz do 400 Hz od 500 µF do 1 mF CMC 0,51 % 400 Hz do 500 Hz od 500 µF do 1 mF CMC 0,59 % 500 Hz do 600 Hz od 500 µF do 1 mF CMC 0,68 % 600 Hz do 700 Hz od 500 µF do 1 mF CMC 0,77 % 700 Hz do 800 Hz od 500 µF do 1 mF CMC 0,85 % 800 Hz do 900 Hz od 500 µF do 1 mF CMC 0,94 % 900 Hz do 1 kHz od 500 µF do 1 mF CMC 1,1 % 1 kHz do 2 kHz od 500 µF do 1 mF CMC 1,9 % 20 Hz do 30 Hz od 1 mF do 5 mF CMC 0,70 % 30 Hz do 40 Hz od 1 mF do 5 mF CMC 0,78 % 40 Hz do 80 Hz od 1 mF do 5 mF CMC 0,89 % 80 Hz do 90 Hz od 1 mF do 5 mF CMC 0,96 % 90 Hz do 160 Hz od 1 mF do 5 mF CMC 1,1 % 160 Hz do 300 Hz od 1 mF do 5 mF CMC 1,7 % 300 Hz do 400 Hz od 1 mF do 5 mF CMC 2,1 % 400 Hz do 500 Hz od 1 mF do 5 mF CMC 2,6 % 500 Hz do 600 Hz od 1 mF do 5 mF CMC 3,0 % 600 Hz do 700 Hz od 1 mF do 5 mF CMC 3,4 % 700 Hz do 800 Hz od 1 mF do 5 mF CMC 3,9 % 800 Hz do 900 Hz od 1 mF do 5 mF CMC 4,3 % 900 Hz do 1 kHz od 1 mF do 5 mF CMC 4,7 % 50 Hz do 60 Hz od 5 mF do 10 mF CMC 1,4 % 60 Hz do 160 Hz od 5 mF do 10 mF CMC 1,9 % 160 Hz do 220 Hz od 5 mF do 10 mF CMC 2,3 % 220 Hz do 300 Hz od 5 mF do 10 mF CMC 3,0 % Kapacita / Etalony kapacity Kalibrace – elektricke veliciny Prime mereni RLC meridlem 10 kHz az 15 kHz 1 pF az 5 pF CMC 2,2 % 15 kHz az 20 kHz 1 pF az 5 pF CMC 1,5 % 20 kHz az 25 kHz 1 pF az 5 pF CMC 1,2 % 25 kHz az 30 kHz 1 pF az 5 pF CMC 0,94 % 30 kHz az 40 kHz 1 pF az 5 pF CMC 0,81 % 40 kHz az 50 kHz 1 pF az 5 pF CMC 0,65 % 50 kHz az 60 kHz 1 pF az 5 pF CMC 0,55 % 60 kHz az 70 kHz 1 pF az 5 pF CMC 0,49 % 70 kHz az 80 kHz 1 pF az 5 pF CMC 0,44 % 80 kHz az 100 kHz 1 pF az 5 pF CMC 0,40 % 100 kHz az 110 kHz 1 pF az 5 pF CMC 0,75 % 110 kHz az 120 kHz 1 pF az 5 pF CMC 0,69 % 120 kHz az 130 kHz 1 pF az 5 pF CMC 0,65 % 130 kHz az 140 kHz 1 pF az 5 pF CMC 0,61 % 140 kHz az 150 kHz 1 pF az 5 pF CMC 0,58 % 150 kHz az 170 kHz 1 pF az 5 pF CMC 0,55 % 170 kHz az 200 kHz 1 pF az 5 pF CMC 0,50 % 200 kHz az 250 kHz 1 pF az 5 pF CMC 0,45 % 250 kHz az 300 kHz 1 pF az 5 pF CMC 0,39 % 300 kHz az 350 kHz 1 pF az 5 pF CMC 0,81 % 350 kHz az 400 kHz 1 pF az 5 pF CMC 0,72 % 400 kHz az 450 kHz 1 pF az 5 pF CMC 0,65 % 450 kHz az 500 kHz 1 pF az 5 pF CMC 0,59 % 500 kHz az 600 kHz 1 pF az 5 pF CMC 0,55 % 600 kHz az 700 kHz 1 pF az 5 pF CMC 0,49 % 700 kHz az 800 kHz 1 pF az 5 pF CMC 0,44 % 800 kHz az 1 MHz 1 pF az 5 pF CMC 0,40 % 1 kHz az 2 kHz 5 pF az 10 pF CMC 4,1 % 2 kHz az 3 kHz 5 pF az 10 pF CMC 2,2 % 3 kHz az 4 kHz 5 pF az 10 pF CMC 1,5 % 4 kHz az 5 kHz 5 pF az 10 pF CMC 1,2 % 5 kHz az 6 kHz 5 pF az 10 pF CMC 0,94 % 6 kHz az 7 kHz 5 pF az 10 pF CMC 0,81 % 7 kHz az 8 kHz 5 pF az 10 pF CMC 0,72 % 8 kHz az 9 kHz 5 pF az 10 pF CMC 0,65 % 9 kHz az 10 kHz 5 pF az 10 pF CMC 0,59 % 10 kHz az 15 kHz 5 pF az 10 pF CMC 0,55 % 15 kHz az 20 kHz 5 pF az 10 pF CMC 0,42 % 20 kHz az 25 kHz 5 pF az 10 pF CMC 0,36 % 25 kHz az 30 kHz 5 pF az 10 pF CMC 0,32 % 30 kHz az 1 MHz 5 pF az 10 pF CMC 0,29 % 500 Hz az 600 Hz 10 pF az 50 pF CMC 4,3 % 600 Hz az 700 Hz 10 pF az 50 pF CMC 3,7 % 700 Hz az 800 Hz 10 pF az 50 pF CMC 3,2 % 800 Hz az 900 Hz 10 pF az 50 pF CMC 2,8 % 900 Hz az 1 kHz 10 pF az 50 pF CMC 2,6 % 1 kHz az 2 kHz 10 pF az 50 pF CMC 2,2 % 2 kHz az 3 kHz 10 pF az 50 pF CMC 1,2 % 3 kHz az 4 kHz 10 pF az 50 pF CMC 0,81 % 4 kHz az 5 kHz 10 pF az 50 pF CMC 0,65 % 5 kHz az 6 kHz 10 pF az 50 pF CMC 0,55 % 6 kHz az 7 kHz 10 pF az 50 pF CMC 0,49 % 7 kHz az 8 kHz 10 pF az 50 pF CMC 0,44 % 8 kHz az 9 kHz 10 pF az 50 pF CMC 0,40 % 9 kHz az 10 kHz 10 pF az 50 pF CMC 0,38 % 10 kHz az 15 kHz 10 pF az 50 pF CMC 0,36 % 15 kHz az 20 kHz 10 pF az 50 pF CMC 0,29 % 20 kHz az 1 MHz 10 pF az 50 pF CMC 0,26 % 100 Hz az 200 Hz 50 pF az 100 pF CMC 4,3 % 200 Hz az 300 Hz 50 pF az 100 pF CMC 2,3 % 300 Hz az 400 Hz 50 pF az 100 pF CMC 1,7 % 400 Hz az 500 Hz 50 pF az 100 pF CMC 1,4 % 500 Hz az 600 Hz 50 pF az 100 pF CMC 1,2 % 600 Hz az 700 Hz 50 pF az 100 pF CMC 0,99 % 700 Hz az 800 Hz 50 pF az 100 pF CMC 0,89 % 800 Hz az 900 Hz 50 pF az 100 pF CMC 0,82 % 900 Hz az 1 kHz 50 pF az 100 pF CMC 0,77 % 1 kHz az 2 kHz 50 pF az 100 pF CMC 0,55 % 2 kHz az 3 kHz 50 pF az 100 pF CMC 0,36 % 3 kHz az 4 kHz 50 pF az 100 pF CMC 0,29 % 4 kHz az 5 kHz 50 pF az 100 pF CMC 0,26 % 5 kHz az 1 MHz 50 pF az 100 pF CMC 0,24 % 50 Hz az 60 Hz 100 pF az 500 pF CMC 9,9 % 60 Hz az 70 Hz 100 pF az 500 pF CMC 7,9 % 70 Hz az 80 Hz 100 pF az 500 pF CMC 6,5 % 80 Hz az 90 Hz 100 pF az 500 pF CMC 5,6 % 90 Hz az 100 Hz 100 pF az 500 pF CMC 4,9 % 100 Hz az 160 Hz 100 pF az 500 pF CMC 2,3 % 160 Hz az 200 Hz 100 pF az 500 pF CMC 1,4 % 200 Hz az 300 Hz 100 pF az 500 pF CMC 1,2 % 300 Hz az 400 Hz 100 pF az 500 pF CMC 0,81 % 400 Hz az 500 Hz 100 pF az 500 pF CMC 0,65 % 500 Hz az 600 Hz 100 pF az 500 pF CMC 0,55 % 600 Hz az 700 Hz 100 pF az 500 pF CMC 0,49 % 700 Hz az 800 Hz 100 pF az 500 pF CMC 0,44 % 800 Hz az 900 Hz 100 pF az 500 pF CMC 0,40 % 900 Hz az 1 kHz 100 pF az 500 pF CMC 0,38 % 1 kHz az 2 kHz 100 pF az 500 pF CMC 0,36 % 2 kHz az 3 kHz 100 pF az 500 pF CMC 0,26 % 3 kHz az 4 kHz 100 pF az 500 pF CMC 0,23 % 4 kHz az 5 kHz 100 pF az 500 pF CMC 0,21 % 5 kHz az 1 MHz 100 pF az 500 pF CMC 0,17 % 50 Hz az 60 Hz 500 pF az 1 nF CMC 2,3 % 60 Hz az 70 Hz 500 pF az 1 nF CMC 1,9 % 70 Hz az 80 Hz 500 pF az 1 nF CMC 1,6 % 80 Hz az 100 Hz 500 pF az 1 nF CMC 1,4 % 100 Hz az 160 Hz 500 pF az 1 nF CMC 0,72 % 160 Hz az 200 Hz 500 pF az 1 nF CMC 0,40 % 200 Hz az 300 Hz 500 pF az 1 nF CMC 0,36 % 300 Hz az 400 Hz 500 pF az 1 nF CMC 0,29 % 400 Hz az 500 Hz 500 pF az 1 nF CMC 0,26 % 500 Hz az 700 Hz 500 pF az 1 nF CMC 0,24 % 700 Hz az 1 kHz 500 pF az 1 nF CMC 0,22 % 1 kHz az 2 kHz 500 pF az 1 nF CMC 0,36 % 2 kHz az 3 kHz 500 pF az 1 nF CMC 0,26 % 3 kHz az 4 kHz 500 pF az 1 nF CMC 0,23 % 4 kHz az 5 kHz 500 pF az 1 nF CMC 0,21 % 5 kHz az 1 MHz 500 pF az 1 nF CMC 0,17 % 20 Hz az 30 Hz 1 nF az 5 nF CMC 3,6 % 30 Hz az 40 Hz 1 nF az 5 nF CMC 2,2 % 40 Hz az 50 Hz 1 nF az 5 nF CMC 1,6 % 50 Hz az 60 Hz 1 nF az 5 nF CMC 1,2 % 60 Hz az 70 Hz 1 nF az 5 nF CMC 0,91 % 70 Hz az 80 Hz 1 nF az 5 nF CMC 0,77 % 80 Hz az 90 Hz 1 nF az 5 nF CMC 0,68 % 90 Hz az 100 Hz 1 nF az 5 nF CMC 0,61 % 100 Hz az 200 Hz 1 nF az 5 nF CMC 0,36 % 200 Hz az 300 Hz 1 nF az 5 nF CMC 0,26 % 300 Hz az 500 Hz 1 nF az 5 nF CMC 0,23 % 500 Hz az 1 MHz 1 nF az 5 nF CMC 0,15 % 20 Hz az 30 Hz 5 nF az 10 nF CMC 0,97 % 30 Hz az 40 Hz 5 nF az 10 nF CMC 0,70 % 40 Hz az 50 Hz 5 nF az 10 nF CMC 0,58 % 50 Hz az 60 Hz 5 nF az 10 nF CMC 0,35 % 60 Hz az 70 Hz 5 nF az 10 nF CMC 0,31 % 70 Hz az 100 Hz 5 nF az 10 nF CMC 0,28 % 100 Hz az 400 Hz 5 nF az 10 nF CMC 0,20 % 400 Hz az 500 Hz 5 nF az 10 nF CMC 0,17 % 500 Hz az 1 MHz 5 nF az 10 nF CMC 0,13 % 20 Hz az 30 Hz 10 nF az 50 nF CMC 0,65 % 30 Hz az 40 Hz 10 nF az 50 nF CMC 0,52 % 40 Hz az 50 Hz 10 nF az 50 nF CMC 0,46 % 50 Hz az 70 Hz 10 nF az 50 nF CMC 0,26 % 70 Hz az 100 Hz 10 nF az 50 nF CMC 0,22 % 100 Hz az 103 kHz 10 nF az 50 nF CMC 0,13 % 103 kHz az 150 kHz 10 nF az 50 nF CMC 0,19 % 150 kHz az 300 kHz 10 nF az 50 nF CMC 0,21 % 300 kHz az 500 kHz 10 nF az 50 nF CMC 0,28 % 500 kHz az 1 MHz 10 nF az 50 nF CMC 0,39 % 20 Hz az 40 Hz 50 nF az 100 nF CMC 0,40 % 40 Hz az 50 Hz 50 nF az 100 nF CMC 0,36 % 50 Hz az 70 Hz 50 nF az 100 nF CMC 0,26 % 70 Hz az 100 Hz 50 nF az 100 nF CMC 0,22 % 100 Hz az 103 kHz 50 nF az 100 nF CMC 0,13 % 103 kHz az 150 kHz 50 nF az 100 nF CMC 0,19 % 150 kHz az 300 kHz 50 nF az 100 nF CMC 0,21 % 300 kHz az 500 kHz 50 nF az 100 nF CMC 0,28 % 500 kHz az 1 MHz 50 nF az 100 nF CMC 0,39 % 20 Hz az 50 Hz 100 nF az 500 nF CMC 0,36 % 50 Hz az 100 Hz 100 nF az 500 nF CMC 0,18 % 100 Hz az 10 kHz 100 nF az 500 nF CMC 0,12 % 10 kHz az 70 kHz 100 nF az 500 nF CMC 0,22 % 70 kHz az 100 kHz 100 nF az 500 nF CMC 0,25 % 100 kHz az 140 kHz 100 nF az 500 nF CMC 0,27 % 140 kHz az 230 kHz 100 nF az 500 nF CMC 0,34 % 230 kHz az 280 kHz 100 nF az 500 nF CMC 0,38 % 280 kHz az 300 kHz 100 nF az 500 nF CMC 0,40 % 300 kHz az 350 kHz 100 nF az 500 nF CMC 0,56 % 350 kHz az 400 kHz 100 nF az 500 nF CMC 0,62 % 400 kHz az 450 kHz 100 nF az 500 nF CMC 0,68 % 450 kHz az 500 kHz 100 nF az 500 nF CMC 0,74 % 500 kHz az 600 kHz 100 nF az 500 nF CMC 0,86 % 600 kHz az 700 kHz 100 nF az 500 nF CMC 0,97 % 700 kHz az 800 kHz 100 nF az 500 nF CMC 1,1 % 800 kHz az 1 MHz 100 nF az 500 nF CMC 1,4 % 20 Hz az 50 Hz 500 nF az 1 µF CMC 0,36 % 50 Hz az 100 Hz 500 nF az 1 µF CMC 0,18 % 100 Hz az 10 kHz 500 nF az 1 µF CMC 0,12 % 10 kHz az 70 kHz 500 nF az 1 µF CMC 0,22 % 70 kHz az 100 kHz 500 nF az 1 µF CMC 0,25 % 100 kHz az 120 kHz 500 nF az 1 µF CMC 0,35 % 120 kHz az 150 kHz 500 nF az 1 µF CMC 0,40 % 150 kHz az 180 kHz 500 nF az 1 µF CMC 0,45 % 180 kHz az 220 kHz 500 nF az 1 µF CMC 0,51 % 220 kHz az 250 kHz 500 nF az 1 µF CMC 0,56 % 250 kHz az 300 kHz 500 nF az 1 µF CMC 0,64 % 300 kHz az 350 kHz 500 nF az 1 µF CMC 0,97 % 350 kHz az 400 kHz 500 nF az 1 µF CMC 1,1 % 400 kHz az 500 kHz 500 nF az 1 µF CMC 1,4 % 500 kHz az 600 kHz 500 nF az 1 µF CMC 1,6 % 600 kHz az 700 kHz 500 nF az 1 µF CMC 1,8 % 700 kHz az 1 MHz 500 nF az 1 µF CMC 2,5 % 20 Hz az 50 Hz 1 µF az 5 µF CMC 0,34 % 50 Hz az 5 kHz 1 µF az 5 µF CMC 0,20 % 5 kHz az 10 kHz 1 µF az 5 µF CMC 0,25 % 10 kHz az 15 kHz 1 µF az 5 µF CMC 0,29 % 15 kHz az 20 kHz 1 µF az 5 µF CMC 0,33 % 20 kHz az 25 kHz 1 µF az 5 µF CMC 0,38 % 25 kHz az 30 kHz 1 µF az 5 µF CMC 0,42 % 30 kHz az 40 kHz 1 µF az 5 µF CMC 0,33 % 40 kHz az 50 kHz 1 µF az 5 µF CMC 0,38 % 50 kHz az 60 kHz 1 µF az 5 µF CMC 0,42 % 60 kHz az 70 kHz 1 µF az 5 µF CMC 0,46 % 70 kHz az 80 kHz 1 µF az 5 µF CMC 0,51 % 80 kHz az 90 kHz 1 µF az 5 µF CMC 0,55 % 90 kHz az 100 kHz 1 µF az 5 µF CMC 0,59 % 100 kHz az 110 kHz 1 µF az 5 µF CMC 1,1 % 110 kHz az 140 kHz 1 µF az 5 µF CMC 1,3 % 140 kHz az 160 kHz 1 µF az 5 µF CMC 1,5 % 160 kHz az 190 kHz 1 µF az 5 µF CMC 1,7 % 190 kHz az 210 kHz 1 µF az 5 µF CMC 1,9 % 210 kHz az 250 kHz 1 µF az 5 µF CMC 2,2 % 250 kHz az 300 kHz 1 µF az 5 µF CMC 2,6 % 300 kHz az 350 kHz 1 µF az 5 µF CMC 4,3 % 350 kHz az 400 kHz 1 µF az 5 µF CMC 4,9 % 400 kHz az 450 kHz 1 µF az 5 µF CMC 5,4 % 450 kHz az 500 kHz 1 µF az 5 µF CMC 6,0 % 20 Hz az 50 Hz 5 µF az 10 µF CMC 0,34 % 50 Hz az 5 kHz 5 µF az 10 µF CMC 0,20 % 5 kHz az 10 kHz 5 µF az 10 µF CMC 0,25 % 10 kHz az 15 kHz 5 µF az 10 µF CMC 0,29 % 15 kHz az 20 kHz 5 µF az 10 µF CMC 0,33 % 20 kHz az 25 kHz 5 µF az 10 µF CMC 0,38 % 25 kHz az 30 kHz 5 µF az 10 µF CMC 0,42 % 30 kHz az 40 kHz 5 µF az 10 µF CMC 0,51 % 40 kHz az 50 kHz 5 µF az 10 µF CMC 0,59 % 50 kHz az 60 kHz 5 µF az 10 µF CMC 0,68 % 60 kHz az 70 kHz 5 µF az 10 µF CMC 0,77 % 70 kHz az 80 kHz 5 µF az 10 µF CMC 0,85 % 80 kHz az 90 kHz 5 µF az 10 µF CMC 0,94 % 90 kHz az 100 kHz 5 µF az 10 µF CMC 1,1 % 100 kHz az 110 kHz 5 µF az 10 µF CMC 2,0 % 110 kHz az 140 kHz 5 µF az 10 µF CMC 2,4 % 140 kHz az 160 kHz 5 µF az 10 µF CMC 2,8 % 160 kHz az 190 kHz 5 µF az 10 µF CMC 3,2 % 190 kHz az 210 kHz 5 µF az 10 µF CMC 3,6 % 210 kHz az 250 kHz 5 µF az 10 µF CMC 4,2 % 250 kHz az 300 kHz 5 µF az 10 µF CMC 5,0 % 20 Hz az 50 Hz 10 µF az 20 µF CMC 0,34 % 50 Hz az 500 Hz 10 µF az 20 µF CMC 0,20 % 500 Hz az 700 Hz 10 µF az 20 µF CMC 0,22 % 700 Hz az 1 kHz 10 µF az 20 µF CMC 0,25 % 1 kHz az 2 kHz 10 µF az 20 µF CMC 0,33 % 2 kHz az 3 kHz 10 µF az 20 µF CMC 0,42 % 3 kHz az 4 kHz 10 µF az 20 µF CMC 0,51 % 4 kHz az 5 kHz 10 µF az 20 µF CMC 0,59 % 5 kHz az 6 kHz 10 µF az 20 µF CMC 0,68 % 6 kHz az 7 kHz 10 µF az 20 µF CMC 0,77 % 7 kHz az 8 kHz 10 µF az 20 µF CMC 0,85 % 8 kHz az 9 kHz 10 µF az 20 µF CMC 0,94 % 9 kHz az 10 kHz 10 µF az 20 µF CMC 1,1 % 10 kHz az 15 kHz 10 µF az 20 µF CMC 1,5 % 15 kHz az 20 kHz 10 µF az 20 µF CMC 1,9 % 20 kHz az 25 kHz 10 µF az 20 µF CMC 2,4 % 25 kHz az 30 kHz 10 µF az 20 µF CMC 2,8 % 30 kHz az 40 kHz 10 µF az 20 µF CMC 1,9 % 40 kHz az 50 kHz 10 µF az 20 µF CMC 2,4 % 50 kHz az 60 kHz 10 µF az 20 µF CMC 2,8 % 60 kHz az 70 kHz 10 µF az 20 µF CMC 3,2 % 70 kHz az 80 kHz 10 µF az 20 µF CMC 3,7 % 80 kHz az 90 kHz 10 µF az 20 µF CMC 4,1 % 90 kHz az 100 kHz 10 µF az 20 µF CMC 4,6 % 20 Hz az 50 Hz 20 µF az 50 µF CMC 0,34 % 50 Hz az 500 Hz 20 µF az 50 µF CMC 0,20 % 500 Hz az 700 Hz 20 µF az 50 µF CMC 0,22 % 700 Hz az 1 kHz 20 µF az 50 µF CMC 0,25 % 1 kHz az 2 kHz 20 µF az 50 µF CMC 0,33 % 2 kHz az 3 kHz 20 µF az 50 µF CMC 0,42 % 3 kHz az 4 kHz 20 µF az 50 µF CMC 0,51 % 4 kHz az 5 kHz 20 µF az 50 µF CMC 0,59 % 5 kHz az 6 kHz 20 µF az 50 µF CMC 0,68 % 6 kHz az 7 kHz 20 µF az 50 µF CMC 0,77 % 7 kHz az 8 kHz 20 µF az 50 µF CMC 0,85 % 8 kHz az 9 kHz 20 µF az 50 µF CMC 0,94 % 9 kHz az 10 kHz 20 µF az 50 µF CMC 1,1 % 10 kHz az 15 kHz 20 µF az 50 µF CMC 1,5 % 15 kHz az 20 kHz 20 µF az 50 µF CMC 1,9 % 20 kHz az 25 kHz 20 µF az 50 µF CMC 2,4 % 25 kHz az 30 kHz 20 µF az 50 µF CMC 2,8 % 30 kHz az 40 kHz 20 µF az 50 µF CMC 1,9 % 40 kHz az 50 kHz 20 µF az 50 µF CMC 2,4 % 20 Hz az 50 Hz 50 µF az 100 µF CMC 0,34 % 50 Hz az 500 Hz 50 µF az 100 µF CMC 0,20 % 500 Hz az 700 Hz 50 µF az 100 µF CMC 0,22 % 700 Hz az 1 kHz 50 µF az 100 µF CMC 0,25 % 1 kHz az 2 kHz 50 µF az 100 µF CMC 0,33 % 2 kHz az 3 kHz 50 µF az 100 µF CMC 0,42 % 3 kHz az 4 kHz 50 µF az 100 µF CMC 0,51 % 4 kHz az 5 kHz 50 µF az 100 µF CMC 0,59 % 5 kHz az 6 kHz 50 µF az 100 µF CMC 0,68 % 6 kHz az 7 kHz 50 µF az 100 µF CMC 0,77 % 7 kHz az 8 kHz 50 µF az 100 µF CMC 0,85 % 8 kHz az 9 kHz 50 µF az 100 µF CMC 0,94 % 9 kHz az 10 kHz 50 µF az 100 µF CMC 1,1 % 10 kHz az 15 kHz 50 µF az 100 µF CMC 1,5 % 15 kHz az 20 kHz 50 µF az 100 µF CMC 1,9 % 20 Hz az 50 Hz 100 µF az 500 µF CMC 0,44 % 50 Hz az 70 Hz 100 µF az 500 µF CMC 0,29 % 70 Hz az 200 Hz 100 µF az 500 µF CMC 0,33 % 200 Hz az 300 Hz 100 µF az 500 µF CMC 0,42 % 300 Hz az 400 Hz 100 µF az 500 µF CMC 0,51 % 400 Hz az 500 Hz 100 µF az 500 µF CMC 0,59 % 500 Hz az 600 Hz 100 µF az 500 µF CMC 0,68 % 600 Hz az 700 Hz 100 µF az 500 µF CMC 0,77 % 700 Hz az 800 Hz 100 µF az 500 µF CMC 0,85 % 800 Hz az 900 Hz 100 µF az 500 µF CMC 0,94 % 900 Hz az 2 kHz 100 µF az 500 µF CMC 1,1 % 2 kHz az 3 kHz 100 µF az 500 µF CMC 1,5 % 3 kHz az 4 kHz 100 µF az 500 µF CMC 1,9 % 4 kHz az 5 kHz 100 µF az 500 µF CMC 2,4 % 20 Hz az 50 Hz 500 µF az 1 mF CMC 0,44 % 50 Hz az 70 Hz 500 µF az 1 mF CMC 0,29 % 70 Hz az 200 Hz 500 µF az 1 mF CMC 0,33 % 200 Hz az 300 Hz 500 µF az 1 mF CMC 0,42 % 300 Hz az 400 Hz 500 µF az 1 mF CMC 0,51 % 400 Hz az 500 Hz 500 µF az 1 mF CMC 0,59 % 500 Hz az 600 Hz 500 µF az 1 mF CMC 0,68 % 600 Hz az 700 Hz 500 µF az 1 mF CMC 0,77 % 700 Hz az 800 Hz 500 µF az 1 mF CMC 0,85 % 800 Hz az 900 Hz 500 µF az 1 mF CMC 0,94 % 900 Hz az 1 kHz 500 µF az 1 mF CMC 1,1 % 1 kHz az 2 kHz 500 µF az 1 mF CMC 1,9 % 20 Hz az 30 Hz 1 mF az 5 mF CMC 0,70 % 30 Hz az 40 Hz 1 mF az 5 mF CMC 0,78 % 40 Hz az 80 Hz 1 mF az 5 mF CMC 0,89 % 80 Hz az 90 Hz 1 mF az 5 mF CMC 0,96 % 90 Hz az 160 Hz 1 mF az 5 mF CMC 1,1 % 160 Hz az 300 Hz 1 mF az 5 mF CMC 1,7 % 300 Hz az 400 Hz 1 mF az 5 mF CMC 2,1 % 400 Hz az 500 Hz 1 mF az 5 mF CMC 2,6 % 500 Hz az 600 Hz 1 mF az 5 mF CMC 3,0 % 600 Hz az 700 Hz 1 mF az 5 mF CMC 3,4 % 700 Hz az 800 Hz 1 mF az 5 mF CMC 3,9 % 800 Hz az 900 Hz 1 mF az 5 mF CMC 4,3 % 900 Hz az 1 kHz 1 mF az 5 mF CMC 4,7 % 50 Hz az 60 Hz 5 mF az 10 mF CMC 1,4 % 60 Hz az 160 Hz 5 mF az 10 mF CMC 1,9 % 160 Hz az 220 Hz 5 mF az 10 mF CMC 2,3 % 220 Hz az 300 Hz 5 mF az 10 mF CMC 3,0 % TP7, TP24","search_en":"Capacity / Capacity standards Calibration – electrical quantities Direct measurement by a RLC meter 10 kHz to 15 kHz 1 pF to 5 pF CMC 2,2 % 15 kHz to 20 kHz 1 pF to 5 pF CMC 1,5 % 20 kHz to 25 kHz 1 pF to 5 pF CMC 1,2 % 25 kHz to 30 kHz 1 pF to 5 pF CMC 0,94 % 30 kHz to 40 kHz 1 pF to 5 pF CMC 0,81 % 40 kHz to 50 kHz 1 pF to 5 pF CMC 0,65 % 50 kHz to 60 kHz 1 pF to 5 pF CMC 0,55 % 60 kHz to 70 kHz 1 pF to 5 pF CMC 0,49 % 70 kHz to 80 kHz 1 pF to 5 pF CMC 0,44 % 80 kHz to 100 kHz 1 pF to 5 pF CMC 0,40 % 100 kHz to 110 kHz 1 pF to 5 pF CMC 0,75 % 110 kHz to 120 kHz 1 pF to 5 pF CMC 0,69 % 120 kHz to 130 kHz 1 pF to 5 pF CMC 0,65 % 130 kHz to 140 kHz 1 pF to 5 pF CMC 0,61 % 140 kHz to 150 kHz 1 pF to 5 pF CMC 0,58 % 150 kHz to 170 kHz 1 pF to 5 pF CMC 0,55 % 170 kHz to 200 kHz 1 pF to 5 pF CMC 0,50 % 200 kHz to 250 kHz 1 pF to 5 pF CMC 0,45 % 250 kHz to 300 kHz 1 pF to 5 pF CMC 0,39 % 300 kHz to 350 kHz 1 pF to 5 pF CMC 0,81 % 350 kHz to 400 kHz 1 pF to 5 pF CMC 0,72 % 400 kHz to 450 kHz 1 pF to 5 pF CMC 0,65 % 450 kHz to 500 kHz 1 pF to 5 pF CMC 0,59 % 500 kHz to 600 kHz 1 pF to 5 pF CMC 0,55 % 600 kHz to 700 kHz 1 pF to 5 pF CMC 0,49 % 700 kHz to 800 kHz 1 pF to 5 pF CMC 0,44 % 800 kHz to 1 MHz 1 pF to 5 pF CMC 0,40 % 1 kHz to 2 kHz 5 pF to 10 pF CMC 4,1 % 2 kHz to 3 kHz 5 pF to 10 pF CMC 2,2 % 3 kHz to 4 kHz 5 pF to 10 pF CMC 1,5 % 4 kHz to 5 kHz 5 pF to 10 pF CMC 1,2 % 5 kHz to 6 kHz 5 pF to 10 pF CMC 0,94 % 6 kHz to 7 kHz 5 pF to 10 pF CMC 0,81 % 7 kHz to 8 kHz 5 pF to 10 pF CMC 0,72 % 8 kHz to 9 kHz 5 pF to 10 pF CMC 0,65 % 9 kHz to 10 kHz 5 pF to 10 pF CMC 0,59 % 10 kHz to 15 kHz 5 pF to 10 pF CMC 0,55 % 15 kHz to 20 kHz 5 pF to 10 pF CMC 0,42 % 20 kHz to 25 kHz 5 pF to 10 pF CMC 0,36 % 25 kHz to 30 kHz 5 pF to 10 pF CMC 0,32 % 30 kHz to 1 MHz 5 pF to 10 pF CMC 0,29 % 500 Hz to 600 Hz 10 pF to 50 pF CMC 4,3 % 600 Hz to 700 Hz 10 pF to 50 pF CMC 3,7 % 700 Hz to 800 Hz 10 pF to 50 pF CMC 3,2 % 800 Hz to 900 Hz 10 pF to 50 pF CMC 2,8 % 900 Hz to 1 kHz 10 pF to 50 pF CMC 2,6 % 1 kHz to 2 kHz 10 pF to 50 pF CMC 2,2 % 2 kHz to 3 kHz 10 pF to 50 pF CMC 1,2 % 3 kHz to 4 kHz 10 pF to 50 pF CMC 0,81 % 4 kHz to 5 kHz 10 pF to 50 pF CMC 0,65 % 5 kHz to 6 kHz 10 pF to 50 pF CMC 0,55 % 6 kHz to 7 kHz 10 pF to 50 pF CMC 0,49 % 7 kHz to 8 kHz 10 pF to 50 pF CMC 0,44 % 8 kHz to 9 kHz 10 pF to 50 pF CMC 0,40 % 9 kHz to 10 kHz 10 pF to 50 pF CMC 0,38 % 10 kHz to 15 kHz 10 pF to 50 pF CMC 0,36 % 15 kHz to 20 kHz 10 pF to 50 pF CMC 0,29 % 20 kHz to 1 MHz 10 pF to 50 pF CMC 0,26 % 100 Hz to 200 Hz 50 pF to 100 pF CMC 4,3 % 200 Hz to 300 Hz 50 pF to 100 pF CMC 2,3 % 300 Hz to 400 Hz 50 pF to 100 pF CMC 1,7 % 400 Hz to 500 Hz 50 pF to 100 pF CMC 1,4 % 500 Hz to 600 Hz 50 pF to 100 pF CMC 1,2 % 600 Hz to 700 Hz 50 pF to 100 pF CMC 0,99 % 700 Hz to 800 Hz 50 pF to 100 pF CMC 0,89 % 800 Hz to 900 Hz 50 pF to 100 pF CMC 0,82 % 900 Hz to 1 kHz 50 pF to 100 pF CMC 0,77 % 1 kHz to 2 kHz 50 pF to 100 pF CMC 0,55 % 2 kHz to 3 kHz 50 pF to 100 pF CMC 0,36 % 3 kHz to 4 kHz 50 pF to 100 pF CMC 0,29 % 4 kHz to 5 kHz 50 pF to 100 pF CMC 0,26 % 5 kHz to 1 MHz 50 pF to 100 pF CMC 0,24 % 50 Hz to 60 Hz 100 pF to 500 pF CMC 9,9 % 60 Hz to 70 Hz 100 pF to 500 pF CMC 7,9 % 70 Hz to 80 Hz 100 pF to 500 pF CMC 6,5 % 80 Hz to 90 Hz 100 pF to 500 pF CMC 5,6 % 90 Hz to 100 Hz 100 pF to 500 pF CMC 4,9 % 100 Hz to 160 Hz 100 pF to 500 pF CMC 2,3 % 160 Hz to 200 Hz 100 pF to 500 pF CMC 1,4 % 200 Hz to 300 Hz 100 pF to 500 pF CMC 1,2 % 300 Hz to 400 Hz 100 pF to 500 pF CMC 0,81 % 400 Hz to 500 Hz 100 pF to 500 pF CMC 0,65 % 500 Hz to 600 Hz 100 pF to 500 pF CMC 0,55 % 600 Hz to 700 Hz 100 pF to 500 pF CMC 0,49 % 700 Hz to 800 Hz 100 pF to 500 pF CMC 0,44 % 800 Hz to 900 Hz 100 pF to 500 pF CMC 0,40 % 900 Hz to 1 kHz 100 pF to 500 pF CMC 0,38 % 1 kHz to 2 kHz 100 pF to 500 pF CMC 0,36 % 2 kHz to 3 kHz 100 pF to 500 pF CMC 0,26 % 3 kHz to 4 kHz 100 pF to 500 pF CMC 0,23 % 4 kHz to 5 kHz 100 pF to 500 pF CMC 0,21 % 5 kHz to 1 MHz 100 pF to 500 pF CMC 0,17 % 50 Hz to 60 Hz 500 pF to 1 nF CMC 2,3 % 60 Hz to 70 Hz 500 pF to 1 nF CMC 1,9 % 70 Hz to 80 Hz 500 pF to 1 nF CMC 1,6 % 80 Hz to 100 Hz 500 pF to 1 nF CMC 1,4 % 100 Hz to 160 Hz 500 pF to 1 nF CMC 0,72 % 160 Hz to 200 Hz 500 pF to 1 nF CMC 0,40 % 200 Hz to 300 Hz 500 pF to 1 nF CMC 0,36 % 300 Hz to 400 Hz 500 pF to 1 nF CMC 0,29 % 400 Hz to 500 Hz 500 pF to 1 nF CMC 0,26 % 500 Hz to 700 Hz 500 pF to 1 nF CMC 0,24 % 700 Hz to 1 kHz 500 pF to 1 nF CMC 0,22 % 1 kHz to 2 kHz 500 pF to 1 nF CMC 0,36 % 2 kHz to 3 kHz 500 pF to 1 nF CMC 0,26 % 3 kHz to 4 kHz 500 pF to 1 nF CMC 0,23 % 4 kHz to 5 kHz 500 pF to 1 nF CMC 0,21 % 5 kHz to 1 MHz 500 pF to 1 nF CMC 0,17 % 20 Hz to 30 Hz 1 nF to 5 nF CMC 3,6 % 30 Hz to 40 Hz 1 nF to 5 nF CMC 2,2 % 40 Hz to 50 Hz 1 nF to 5 nF CMC 1,6 % 50 Hz to 60 Hz 1 nF to 5 nF CMC 1,2 % 60 Hz to 70 Hz 1 nF to 5 nF CMC 0,91 % 70 Hz to 80 Hz 1 nF to 5 nF CMC 0,77 % 80 Hz to 90 Hz 1 nF to 5 nF CMC 0,68 % 90 Hz to 100 Hz 1 nF to 5 nF CMC 0,61 % 100 Hz to 200 Hz 1 nF to 5 nF CMC 0,36 % 200 Hz to 300 Hz 1 nF to 5 nF CMC 0,26 % 300 Hz to 500 Hz 1 nF to 5 nF CMC 0,23 % 500 Hz to 1 MHz 1 nF to 5 nF CMC 0,15 % 20 Hz to 30 Hz 5 nF to 10 nF CMC 0,97 % 30 Hz to 40 Hz 5 nF to 10 nF CMC 0,70 % 40 Hz to 50 Hz 5 nF to 10 nF CMC 0,58 % 50 Hz to 60 Hz 5 nF to 10 nF CMC 0,35 % 60 Hz to 70 Hz 5 nF to 10 nF CMC 0,31 % 70 Hz to 100 Hz 5 nF to 10 nF CMC 0,28 % 100 Hz to 400 Hz 5 nF to 10 nF CMC 0,20 % 400 Hz to 500 Hz 5 nF to 10 nF CMC 0,17 % 500 Hz to 1 MHz 5 nF to 10 nF CMC 0,13 % 20 Hz to 30 Hz 10 nF to 50 nF CMC 0,65 % 30 Hz to 40 Hz 10 nF to 50 nF CMC 0,52 % 40 Hz to 50 Hz 10 nF to 50 nF CMC 0,46 % 50 Hz to 70 Hz 10 nF to 50 nF CMC 0,26 % 70 Hz to 100 Hz 10 nF to 50 nF CMC 0,22 % 100 Hz to 103 kHz 10 nF to 50 nF CMC 0,13 % 103 kHz to 150 kHz 10 nF to 50 nF CMC 0,19 % 150 kHz to 300 kHz 10 nF to 50 nF CMC 0,21 % 300 kHz to 500 kHz 10 nF to 50 nF CMC 0,28 % 500 kHz to 1 MHz 10 nF to 50 nF CMC 0,39 % 20 Hz to 40 Hz 50 nF to 100 nF CMC 0,40 % 40 Hz to 50 Hz 50 nF to 100 nF CMC 0,36 % 50 Hz to 70 Hz 50 nF to 100 nF CMC 0,26 % 70 Hz to 100 Hz 50 nF to 100 nF CMC 0,22 % 100 Hz to 103 kHz 50 nF to 100 nF CMC 0,13 % 103 kHz to 150 kHz 50 nF to 100 nF CMC 0,19 % 150 kHz to 300 kHz 50 nF to 100 nF CMC 0,21 % 300 kHz to 500 kHz 50 nF to 100 nF CMC 0,28 % 500 kHz to 1 MHz 50 nF to 100 nF CMC 0,39 % 20 Hz to 50 Hz 100 nF to 500 nF CMC 0,36 % 50 Hz to 100 Hz 100 nF to 500 nF CMC 0,18 % 100 Hz to 10 kHz 100 nF to 500 nF CMC 0,12 % 10 kHz to 70 kHz 100 nF to 500 nF CMC 0,22 % 70 kHz to 100 kHz 100 nF to 500 nF CMC 0,25 % 100 kHz to 140 kHz 100 nF to 500 nF CMC 0,27 % 140 kHz to 230 kHz 100 nF to 500 nF CMC 0,34 % 230 kHz to 280 kHz 100 nF to 500 nF CMC 0,38 % 280 kHz to 300 kHz 100 nF to 500 nF CMC 0,40 % 300 kHz to 350 kHz 100 nF to 500 nF CMC 0,56 % 350 kHz to 400 kHz 100 nF to 500 nF CMC 0,62 % 400 kHz to 450 kHz 100 nF to 500 nF CMC 0,68 % 450 kHz to 500 kHz 100 nF to 500 nF CMC 0,74 % 500 kHz to 600 kHz 100 nF to 500 nF CMC 0,86 % 600 kHz to 700 kHz 100 nF to 500 nF CMC 0,97 % 700 kHz to 800 kHz 100 nF to 500 nF CMC 1,1 % 800 kHz to 1 MHz 100 nF to 500 nF CMC 1,4 % 20 Hz to 50 Hz 500 nF to 1 µF CMC 0,36 % 50 Hz to 100 Hz 500 nF to 1 µF CMC 0,18 % 100 Hz to 10 kHz 500 nF to 1 µF CMC 0,12 % 10 kHz to 70 kHz 500 nF to 1 µF CMC 0,22 % 70 kHz to 100 kHz 500 nF to 1 µF CMC 0,25 % 100 kHz to 120 kHz 500 nF to 1 µF CMC 0,35 % 120 kHz to 150 kHz 500 nF to 1 µF CMC 0,40 % 150 kHz to 180 kHz 500 nF to 1 µF CMC 0,45 % 180 kHz to 220 kHz 500 nF to 1 µF CMC 0,51 % 220 kHz to 250 kHz 500 nF to 1 µF CMC 0,56 % 250 kHz to 300 kHz 500 nF to 1 µF CMC 0,64 % 300 kHz to 350 kHz 500 nF to 1 µF CMC 0,97 % 350 kHz to 400 kHz 500 nF to 1 µF CMC 1,1 % 400 kHz to 500 kHz 500 nF to 1 µF CMC 1,4 % 500 kHz to 600 kHz 500 nF to 1 µF CMC 1,6 % 600 kHz to 700 kHz 500 nF to 1 µF CMC 1,8 % 700 kHz to 1 MHz 500 nF to 1 µF CMC 2,5 % 20 Hz to 50 Hz 1 µF to 5 µF CMC 0,34 % 50 Hz to 5 kHz 1 µF to 5 µF CMC 0,20 % 5 kHz to 10 kHz 1 µF to 5 µF CMC 0,25 % 10 kHz to 15 kHz 1 µF to 5 µF CMC 0,29 % 15 kHz to 20 kHz 1 µF to 5 µF CMC 0,33 % 20 kHz to 25 kHz 1 µF to 5 µF CMC 0,38 % 25 kHz to 30 kHz 1 µF to 5 µF CMC 0,42 % 30 kHz to 40 kHz 1 µF to 5 µF CMC 0,33 % 40 kHz to 50 kHz 1 µF to 5 µF CMC 0,38 % 50 kHz to 60 kHz 1 µF to 5 µF CMC 0,42 % 60 kHz to 70 kHz 1 µF to 5 µF CMC 0,46 % 70 kHz to 80 kHz 1 µF to 5 µF CMC 0,51 % 80 kHz to 90 kHz 1 µF to 5 µF CMC 0,55 % 90 kHz to 100 kHz 1 µF to 5 µF CMC 0,59 % 100 kHz to 110 kHz 1 µF to 5 µF CMC 1,1 % 110 kHz to 140 kHz 1 µF to 5 µF CMC 1,3 % 140 kHz to 160 kHz 1 µF to 5 µF CMC 1,5 % 160 kHz to 190 kHz 1 µF to 5 µF CMC 1,7 % 190 kHz to 210 kHz 1 µF to 5 µF CMC 1,9 % 210 kHz to 250 kHz 1 µF to 5 µF CMC 2,2 % 250 kHz to 300 kHz 1 µF to 5 µF CMC 2,6 % 300 kHz to 350 kHz 1 µF to 5 µF CMC 4,3 % 350 kHz to 400 kHz 1 µF to 5 µF CMC 4,9 % 400 kHz to 450 kHz 1 µF to 5 µF CMC 5,4 % 450 kHz to 500 kHz 1 µF to 5 µF CMC 6,0 % 20 Hz to 50 Hz 5 µF to 10 µF CMC 0,34 % 50 Hz to 5 kHz 5 µF to 10 µF CMC 0,20 % 5 kHz to 10 kHz 5 µF to 10 µF CMC 0,25 % 10 kHz to 15 kHz 5 µF to 10 µF CMC 0,29 % 15 kHz to 20 kHz 5 µF to 10 µF CMC 0,33 % 20 kHz to 25 kHz 5 µF to 10 µF CMC 0,38 % 25 kHz to 30 kHz 5 µF to 10 µF CMC 0,42 % 30 kHz to 40 kHz 5 µF to 10 µF CMC 0,51 % 40 kHz to 50 kHz 5 µF to 10 µF CMC 0,59 % 50 kHz to 60 kHz 5 µF to 10 µF CMC 0,68 % 60 kHz to 70 kHz 5 µF to 10 µF CMC 0,77 % 70 kHz to 80 kHz 5 µF to 10 µF CMC 0,85 % 80 kHz to 90 kHz 5 µF to 10 µF CMC 0,94 % 90 kHz to 100 kHz 5 µF to 10 µF CMC 1,1 % 100 kHz to 110 kHz 5 µF to 10 µF CMC 2,0 % 110 kHz to 140 kHz 5 µF to 10 µF CMC 2,4 % 140 kHz to 160 kHz 5 µF to 10 µF CMC 2,8 % 160 kHz to 190 kHz 5 µF to 10 µF CMC 3,2 % 190 kHz to 210 kHz 5 µF to 10 µF CMC 3,6 % 210 kHz to 250 kHz 5 µF to 10 µF CMC 4,2 % 250 kHz to 300 kHz 5 µF to 10 µF CMC 5,0 % 20 Hz to 50 Hz 10 µF to 20 µF CMC 0,34 % 50 Hz to 500 Hz 10 µF to 20 µF CMC 0,20 % 500 Hz to 700 Hz 10 µF to 20 µF CMC 0,22 % 700 Hz to 1 kHz 10 µF to 20 µF CMC 0,25 % 1 kHz to 2 kHz 10 µF to 20 µF CMC 0,33 % 2 kHz to 3 kHz 10 µF to 20 µF CMC 0,42 % 3 kHz to 4 kHz 10 µF to 20 µF CMC 0,51 % 4 kHz to 5 kHz 10 µF to 20 µF CMC 0,59 % 5 kHz to 6 kHz 10 µF to 20 µF CMC 0,68 % 6 kHz to 7 kHz 10 µF to 20 µF CMC 0,77 % 7 kHz to 8 kHz 10 µF to 20 µF CMC 0,85 % 8 kHz to 9 kHz 10 µF to 20 µF CMC 0,94 % 9 kHz to 10 kHz 10 µF to 20 µF CMC 1,1 % 10 kHz to 15 kHz 10 µF to 20 µF CMC 1,5 % 15 kHz to 20 kHz 10 µF to 20 µF CMC 1,9 % 20 kHz to 25 kHz 10 µF to 20 µF CMC 2,4 % 25 kHz to 30 kHz 10 µF to 20 µF CMC 2,8 % 30 kHz to 40 kHz 10 µF to 20 µF CMC 1,9 % 40 kHz to 50 kHz 10 µF to 20 µF CMC 2,4 % 50 kHz to 60 kHz 10 µF to 20 µF CMC 2,8 % 60 kHz to 70 kHz 10 µF to 20 µF CMC 3,2 % 70 kHz to 80 kHz 10 µF to 20 µF CMC 3,7 % 80 kHz to 90 kHz 10 µF to 20 µF CMC 4,1 % 90 kHz to 100 kHz 10 µF to 20 µF CMC 4,6 % 20 Hz to 50 Hz 20 µF to 50 µF CMC 0,34 % 50 Hz to 500 Hz 20 µF to 50 µF CMC 0,20 % 500 Hz to 700 Hz 20 µF to 50 µF CMC 0,22 % 700 Hz to 1 kHz 20 µF to 50 µF CMC 0,25 % 1 kHz to 2 kHz 20 µF to 50 µF CMC 0,33 % 2 kHz to 3 kHz 20 µF to 50 µF CMC 0,42 % 3 kHz to 4 kHz 20 µF to 50 µF CMC 0,51 % 4 kHz to 5 kHz 20 µF to 50 µF CMC 0,59 % 5 kHz to 6 kHz 20 µF to 50 µF CMC 0,68 % 6 kHz to 7 kHz 20 µF to 50 µF CMC 0,77 % 7 kHz to 8 kHz 20 µF to 50 µF CMC 0,85 % 8 kHz to 9 kHz 20 µF to 50 µF CMC 0,94 % 9 kHz to 10 kHz 20 µF to 50 µF CMC 1,1 % 10 kHz to 15 kHz 20 µF to 50 µF CMC 1,5 % 15 kHz to 20 kHz 20 µF to 50 µF CMC 1,9 % 20 kHz to 25 kHz 20 µF to 50 µF CMC 2,4 % 25 kHz to 30 kHz 20 µF to 50 µF CMC 2,8 % 30 kHz to 40 kHz 20 µF to 50 µF CMC 1,9 % 40 kHz to 50 kHz 20 µF to 50 µF CMC 2,4 % 20 Hz to 50 Hz 50 µF to 100 µF CMC 0,34 % 50 Hz to 500 Hz 50 µF to 100 µF CMC 0,20 % 500 Hz to 700 Hz 50 µF to 100 µF CMC 0,22 % 700 Hz to 1 kHz 50 µF to 100 µF CMC 0,25 % 1 kHz to 2 kHz 50 µF to 100 µF CMC 0,33 % 2 kHz to 3 kHz 50 µF to 100 µF CMC 0,42 % 3 kHz to 4 kHz 50 µF to 100 µF CMC 0,51 % 4 kHz to 5 kHz 50 µF to 100 µF CMC 0,59 % 5 kHz to 6 kHz 50 µF to 100 µF CMC 0,68 % 6 kHz to 7 kHz 50 µF to 100 µF CMC 0,77 % 7 kHz to 8 kHz 50 µF to 100 µF CMC 0,85 % 8 kHz to 9 kHz 50 µF to 100 µF CMC 0,94 % 9 kHz to 10 kHz 50 µF to 100 µF CMC 1,1 % 10 kHz to 15 kHz 50 µF to 100 µF CMC 1,5 % 15 kHz to 20 kHz 50 µF to 100 µF CMC 1,9 % 20 Hz to 50 Hz 100 µF to 500 µF CMC 0,44 % 50 Hz to 70 Hz 100 µF to 500 µF CMC 0,29 % 70 Hz to 200 Hz 100 µF to 500 µF CMC 0,33 % 200 Hz to 300 Hz 100 µF to 500 µF CMC 0,42 % 300 Hz to 400 Hz 100 µF to 500 µF CMC 0,51 % 400 Hz to 500 Hz 100 µF to 500 µF CMC 0,59 % 500 Hz to 600 Hz 100 µF to 500 µF CMC 0,68 % 600 Hz to 700 Hz 100 µF to 500 µF CMC 0,77 % 700 Hz to 800 Hz 100 µF to 500 µF CMC 0,85 % 800 Hz to 900 Hz 100 µF to 500 µF CMC 0,94 % 900 Hz to 2 kHz 100 µF to 500 µF CMC 1,1 % 2 kHz to 3 kHz 100 µF to 500 µF CMC 1,5 % 3 kHz to 4 kHz 100 µF to 500 µF CMC 1,9 % 4 kHz to 5 kHz 100 µF to 500 µF CMC 2,4 % 20 Hz to 50 Hz 500 µF to 1 mF CMC 0,44 % 50 Hz to 70 Hz 500 µF to 1 mF CMC 0,29 % 70 Hz to 200 Hz 500 µF to 1 mF CMC 0,33 % 200 Hz to 300 Hz 500 µF to 1 mF CMC 0,42 % 300 Hz to 400 Hz 500 µF to 1 mF CMC 0,51 % 400 Hz to 500 Hz 500 µF to 1 mF CMC 0,59 % 500 Hz to 600 Hz 500 µF to 1 mF CMC 0,68 % 600 Hz to 700 Hz 500 µF to 1 mF CMC 0,77 % 700 Hz to 800 Hz 500 µF to 1 mF CMC 0,85 % 800 Hz to 900 Hz 500 µF to 1 mF CMC 0,94 % 900 Hz to 1 kHz 500 µF to 1 mF CMC 1,1 % 1 kHz to 2 kHz 500 µF to 1 mF CMC 1,9 % 20 Hz to 30 Hz 1 mF to 5 mF CMC 0,70 % 30 Hz to 40 Hz 1 mF to 5 mF CMC 0,78 % 40 Hz to 80 Hz 1 mF to 5 mF CMC 0,89 % 80 Hz to 90 Hz 1 mF to 5 mF CMC 0,96 % 90 Hz to 160 Hz 1 mF to 5 mF CMC 1,1 % 160 Hz to 300 Hz 1 mF to 5 mF CMC 1,7 % 300 Hz to 400 Hz 1 mF to 5 mF CMC 2,1 % 400 Hz to 500 Hz 1 mF to 5 mF CMC 2,6 % 500 Hz to 600 Hz 1 mF to 5 mF CMC 3,0 % 600 Hz to 700 Hz 1 mF to 5 mF CMC 3,4 % 700 Hz to 800 Hz 1 mF to 5 mF CMC 3,9 % 800 Hz to 900 Hz 1 mF to 5 mF CMC 4,3 % 900 Hz to 1 kHz 1 mF to 5 mF CMC 4,7 % 50 Hz to 60 Hz 5 mF to 10 mF CMC 1,4 % 60 Hz to 160 Hz 5 mF to 10 mF CMC 1,9 % 160 Hz to 220 Hz 5 mF to 10 mF CMC 2,3 % 220 Hz to 300 Hz 5 mF to 10 mF CMC 3,0 % TP7, TP24","search_zh":"电容 / 电容标准器 校准 – 电学量 用 RLC 表直接测量 10 kHz 至 15 kHz 1 pF 至 5 pF CMC 2,2 % 15 kHz 至 20 kHz 1 pF 至 5 pF CMC 1,5 % 20 kHz 至 25 kHz 1 pF 至 5 pF CMC 1,2 % 25 kHz 至 30 kHz 1 pF 至 5 pF CMC 0,94 % 30 kHz 至 40 kHz 1 pF 至 5 pF CMC 0,81 % 40 kHz 至 50 kHz 1 pF 至 5 pF CMC 0,65 % 50 kHz 至 60 kHz 1 pF 至 5 pF CMC 0,55 % 60 kHz 至 70 kHz 1 pF 至 5 pF CMC 0,49 % 70 kHz 至 80 kHz 1 pF 至 5 pF CMC 0,44 % 80 kHz 至 100 kHz 1 pF 至 5 pF CMC 0,40 % 100 kHz 至 110 kHz 1 pF 至 5 pF CMC 0,75 % 110 kHz 至 120 kHz 1 pF 至 5 pF CMC 0,69 % 120 kHz 至 130 kHz 1 pF 至 5 pF CMC 0,65 % 130 kHz 至 140 kHz 1 pF 至 5 pF CMC 0,61 % 140 kHz 至 150 kHz 1 pF 至 5 pF CMC 0,58 % 150 kHz 至 170 kHz 1 pF 至 5 pF CMC 0,55 % 170 kHz 至 200 kHz 1 pF 至 5 pF CMC 0,50 % 200 kHz 至 250 kHz 1 pF 至 5 pF CMC 0,45 % 250 kHz 至 300 kHz 1 pF 至 5 pF CMC 0,39 % 300 kHz 至 350 kHz 1 pF 至 5 pF CMC 0,81 % 350 kHz 至 400 kHz 1 pF 至 5 pF CMC 0,72 % 400 kHz 至 450 kHz 1 pF 至 5 pF CMC 0,65 % 450 kHz 至 500 kHz 1 pF 至 5 pF CMC 0,59 % 500 kHz 至 600 kHz 1 pF 至 5 pF CMC 0,55 % 600 kHz 至 700 kHz 1 pF 至 5 pF CMC 0,49 % 700 kHz 至 800 kHz 1 pF 至 5 pF CMC 0,44 % 800 kHz 至 1 MHz 1 pF 至 5 pF CMC 0,40 % 1 kHz 至 2 kHz 5 pF 至 10 pF CMC 4,1 % 2 kHz 至 3 kHz 5 pF 至 10 pF CMC 2,2 % 3 kHz 至 4 kHz 5 pF 至 10 pF CMC 1,5 % 4 kHz 至 5 kHz 5 pF 至 10 pF CMC 1,2 % 5 kHz 至 6 kHz 5 pF 至 10 pF CMC 0,94 % 6 kHz 至 7 kHz 5 pF 至 10 pF CMC 0,81 % 7 kHz 至 8 kHz 5 pF 至 10 pF CMC 0,72 % 8 kHz 至 9 kHz 5 pF 至 10 pF CMC 0,65 % 9 kHz 至 10 kHz 5 pF 至 10 pF CMC 0,59 % 10 kHz 至 15 kHz 5 pF 至 10 pF CMC 0,55 % 15 kHz 至 20 kHz 5 pF 至 10 pF CMC 0,42 % 20 kHz 至 25 kHz 5 pF 至 10 pF CMC 0,36 % 25 kHz 至 30 kHz 5 pF 至 10 pF CMC 0,32 % 30 kHz 至 1 MHz 5 pF 至 10 pF CMC 0,29 % 500 Hz 至 600 Hz 10 pF 至 50 pF CMC 4,3 % 600 Hz 至 700 Hz 10 pF 至 50 pF CMC 3,7 % 700 Hz 至 800 Hz 10 pF 至 50 pF CMC 3,2 % 800 Hz 至 900 Hz 10 pF 至 50 pF CMC 2,8 % 900 Hz 至 1 kHz 10 pF 至 50 pF CMC 2,6 % 1 kHz 至 2 kHz 10 pF 至 50 pF CMC 2,2 % 2 kHz 至 3 kHz 10 pF 至 50 pF CMC 1,2 % 3 kHz 至 4 kHz 10 pF 至 50 pF CMC 0,81 % 4 kHz 至 5 kHz 10 pF 至 50 pF CMC 0,65 % 5 kHz 至 6 kHz 10 pF 至 50 pF CMC 0,55 % 6 kHz 至 7 kHz 10 pF 至 50 pF CMC 0,49 % 7 kHz 至 8 kHz 10 pF 至 50 pF CMC 0,44 % 8 kHz 至 9 kHz 10 pF 至 50 pF CMC 0,40 % 9 kHz 至 10 kHz 10 pF 至 50 pF CMC 0,38 % 10 kHz 至 15 kHz 10 pF 至 50 pF CMC 0,36 % 15 kHz 至 20 kHz 10 pF 至 50 pF CMC 0,29 % 20 kHz 至 1 MHz 10 pF 至 50 pF CMC 0,26 % 100 Hz 至 200 Hz 50 pF 至 100 pF CMC 4,3 % 200 Hz 至 300 Hz 50 pF 至 100 pF CMC 2,3 % 300 Hz 至 400 Hz 50 pF 至 100 pF CMC 1,7 % 400 Hz 至 500 Hz 50 pF 至 100 pF CMC 1,4 % 500 Hz 至 600 Hz 50 pF 至 100 pF CMC 1,2 % 600 Hz 至 700 Hz 50 pF 至 100 pF CMC 0,99 % 700 Hz 至 800 Hz 50 pF 至 100 pF CMC 0,89 % 800 Hz 至 900 Hz 50 pF 至 100 pF CMC 0,82 % 900 Hz 至 1 kHz 50 pF 至 100 pF CMC 0,77 % 1 kHz 至 2 kHz 50 pF 至 100 pF CMC 0,55 % 2 kHz 至 3 kHz 50 pF 至 100 pF CMC 0,36 % 3 kHz 至 4 kHz 50 pF 至 100 pF CMC 0,29 % 4 kHz 至 5 kHz 50 pF 至 100 pF CMC 0,26 % 5 kHz 至 1 MHz 50 pF 至 100 pF CMC 0,24 % 50 Hz 至 60 Hz 100 pF 至 500 pF CMC 9,9 % 60 Hz 至 70 Hz 100 pF 至 500 pF CMC 7,9 % 70 Hz 至 80 Hz 100 pF 至 500 pF CMC 6,5 % 80 Hz 至 90 Hz 100 pF 至 500 pF CMC 5,6 % 90 Hz 至 100 Hz 100 pF 至 500 pF CMC 4,9 % 100 Hz 至 160 Hz 100 pF 至 500 pF CMC 2,3 % 160 Hz 至 200 Hz 100 pF 至 500 pF CMC 1,4 % 200 Hz 至 300 Hz 100 pF 至 500 pF CMC 1,2 % 300 Hz 至 400 Hz 100 pF 至 500 pF CMC 0,81 % 400 Hz 至 500 Hz 100 pF 至 500 pF CMC 0,65 % 500 Hz 至 600 Hz 100 pF 至 500 pF CMC 0,55 % 600 Hz 至 700 Hz 100 pF 至 500 pF CMC 0,49 % 700 Hz 至 800 Hz 100 pF 至 500 pF CMC 0,44 % 800 Hz 至 900 Hz 100 pF 至 500 pF CMC 0,40 % 900 Hz 至 1 kHz 100 pF 至 500 pF CMC 0,38 % 1 kHz 至 2 kHz 100 pF 至 500 pF CMC 0,36 % 2 kHz 至 3 kHz 100 pF 至 500 pF CMC 0,26 % 3 kHz 至 4 kHz 100 pF 至 500 pF CMC 0,23 % 4 kHz 至 5 kHz 100 pF 至 500 pF CMC 0,21 % 5 kHz 至 1 MHz 100 pF 至 500 pF CMC 0,17 % 50 Hz 至 60 Hz 500 pF 至 1 nF CMC 2,3 % 60 Hz 至 70 Hz 500 pF 至 1 nF CMC 1,9 % 70 Hz 至 80 Hz 500 pF 至 1 nF CMC 1,6 % 80 Hz 至 100 Hz 500 pF 至 1 nF CMC 1,4 % 100 Hz 至 160 Hz 500 pF 至 1 nF CMC 0,72 % 160 Hz 至 200 Hz 500 pF 至 1 nF CMC 0,40 % 200 Hz 至 300 Hz 500 pF 至 1 nF CMC 0,36 % 300 Hz 至 400 Hz 500 pF 至 1 nF CMC 0,29 % 400 Hz 至 500 Hz 500 pF 至 1 nF CMC 0,26 % 500 Hz 至 700 Hz 500 pF 至 1 nF CMC 0,24 % 700 Hz 至 1 kHz 500 pF 至 1 nF CMC 0,22 % 1 kHz 至 2 kHz 500 pF 至 1 nF CMC 0,36 % 2 kHz 至 3 kHz 500 pF 至 1 nF CMC 0,26 % 3 kHz 至 4 kHz 500 pF 至 1 nF CMC 0,23 % 4 kHz 至 5 kHz 500 pF 至 1 nF CMC 0,21 % 5 kHz 至 1 MHz 500 pF 至 1 nF CMC 0,17 % 20 Hz 至 30 Hz 1 nF 至 5 nF CMC 3,6 % 30 Hz 至 40 Hz 1 nF 至 5 nF CMC 2,2 % 40 Hz 至 50 Hz 1 nF 至 5 nF CMC 1,6 % 50 Hz 至 60 Hz 1 nF 至 5 nF CMC 1,2 % 60 Hz 至 70 Hz 1 nF 至 5 nF CMC 0,91 % 70 Hz 至 80 Hz 1 nF 至 5 nF CMC 0,77 % 80 Hz 至 90 Hz 1 nF 至 5 nF CMC 0,68 % 90 Hz 至 100 Hz 1 nF 至 5 nF CMC 0,61 % 100 Hz 至 200 Hz 1 nF 至 5 nF CMC 0,36 % 200 Hz 至 300 Hz 1 nF 至 5 nF CMC 0,26 % 300 Hz 至 500 Hz 1 nF 至 5 nF CMC 0,23 % 500 Hz 至 1 MHz 1 nF 至 5 nF CMC 0,15 % 20 Hz 至 30 Hz 5 nF 至 10 nF CMC 0,97 % 30 Hz 至 40 Hz 5 nF 至 10 nF CMC 0,70 % 40 Hz 至 50 Hz 5 nF 至 10 nF CMC 0,58 % 50 Hz 至 60 Hz 5 nF 至 10 nF CMC 0,35 % 60 Hz 至 70 Hz 5 nF 至 10 nF CMC 0,31 % 70 Hz 至 100 Hz 5 nF 至 10 nF CMC 0,28 % 100 Hz 至 400 Hz 5 nF 至 10 nF CMC 0,20 % 400 Hz 至 500 Hz 5 nF 至 10 nF CMC 0,17 % 500 Hz 至 1 MHz 5 nF 至 10 nF CMC 0,13 % 20 Hz 至 30 Hz 10 nF 至 50 nF CMC 0,65 % 30 Hz 至 40 Hz 10 nF 至 50 nF CMC 0,52 % 40 Hz 至 50 Hz 10 nF 至 50 nF CMC 0,46 % 50 Hz 至 70 Hz 10 nF 至 50 nF CMC 0,26 % 70 Hz 至 100 Hz 10 nF 至 50 nF CMC 0,22 % 100 Hz 至 103 kHz 10 nF 至 50 nF CMC 0,13 % 103 kHz 至 150 kHz 10 nF 至 50 nF CMC 0,19 % 150 kHz 至 300 kHz 10 nF 至 50 nF CMC 0,21 % 300 kHz 至 500 kHz 10 nF 至 50 nF CMC 0,28 % 500 kHz 至 1 MHz 10 nF 至 50 nF CMC 0,39 % 20 Hz 至 40 Hz 50 nF 至 100 nF CMC 0,40 % 40 Hz 至 50 Hz 50 nF 至 100 nF CMC 0,36 % 50 Hz 至 70 Hz 50 nF 至 100 nF CMC 0,26 % 70 Hz 至 100 Hz 50 nF 至 100 nF CMC 0,22 % 100 Hz 至 103 kHz 50 nF 至 100 nF CMC 0,13 % 103 kHz 至 150 kHz 50 nF 至 100 nF CMC 0,19 % 150 kHz 至 300 kHz 50 nF 至 100 nF CMC 0,21 % 300 kHz 至 500 kHz 50 nF 至 100 nF CMC 0,28 % 500 kHz 至 1 MHz 50 nF 至 100 nF CMC 0,39 % 20 Hz 至 50 Hz 100 nF 至 500 nF CMC 0,36 % 50 Hz 至 100 Hz 100 nF 至 500 nF CMC 0,18 % 100 Hz 至 10 kHz 100 nF 至 500 nF CMC 0,12 % 10 kHz 至 70 kHz 100 nF 至 500 nF CMC 0,22 % 70 kHz 至 100 kHz 100 nF 至 500 nF CMC 0,25 % 100 kHz 至 140 kHz 100 nF 至 500 nF CMC 0,27 % 140 kHz 至 230 kHz 100 nF 至 500 nF CMC 0,34 % 230 kHz 至 280 kHz 100 nF 至 500 nF CMC 0,38 % 280 kHz 至 300 kHz 100 nF 至 500 nF CMC 0,40 % 300 kHz 至 350 kHz 100 nF 至 500 nF CMC 0,56 % 350 kHz 至 400 kHz 100 nF 至 500 nF CMC 0,62 % 400 kHz 至 450 kHz 100 nF 至 500 nF CMC 0,68 % 450 kHz 至 500 kHz 100 nF 至 500 nF CMC 0,74 % 500 kHz 至 600 kHz 100 nF 至 500 nF CMC 0,86 % 600 kHz 至 700 kHz 100 nF 至 500 nF CMC 0,97 % 700 kHz 至 800 kHz 100 nF 至 500 nF CMC 1,1 % 800 kHz 至 1 MHz 100 nF 至 500 nF CMC 1,4 % 20 Hz 至 50 Hz 500 nF 至 1 µF CMC 0,36 % 50 Hz 至 100 Hz 500 nF 至 1 µF CMC 0,18 % 100 Hz 至 10 kHz 500 nF 至 1 µF CMC 0,12 % 10 kHz 至 70 kHz 500 nF 至 1 µF CMC 0,22 % 70 kHz 至 100 kHz 500 nF 至 1 µF CMC 0,25 % 100 kHz 至 120 kHz 500 nF 至 1 µF CMC 0,35 % 120 kHz 至 150 kHz 500 nF 至 1 µF CMC 0,40 % 150 kHz 至 180 kHz 500 nF 至 1 µF CMC 0,45 % 180 kHz 至 220 kHz 500 nF 至 1 µF CMC 0,51 % 220 kHz 至 250 kHz 500 nF 至 1 µF CMC 0,56 % 250 kHz 至 300 kHz 500 nF 至 1 µF CMC 0,64 % 300 kHz 至 350 kHz 500 nF 至 1 µF CMC 0,97 % 350 kHz 至 400 kHz 500 nF 至 1 µF CMC 1,1 % 400 kHz 至 500 kHz 500 nF 至 1 µF CMC 1,4 % 500 kHz 至 600 kHz 500 nF 至 1 µF CMC 1,6 % 600 kHz 至 700 kHz 500 nF 至 1 µF CMC 1,8 % 700 kHz 至 1 MHz 500 nF 至 1 µF CMC 2,5 % 20 Hz 至 50 Hz 1 µF 至 5 µF CMC 0,34 % 50 Hz 至 5 kHz 1 µF 至 5 µF CMC 0,20 % 5 kHz 至 10 kHz 1 µF 至 5 µF CMC 0,25 % 10 kHz 至 15 kHz 1 µF 至 5 µF CMC 0,29 % 15 kHz 至 20 kHz 1 µF 至 5 µF CMC 0,33 % 20 kHz 至 25 kHz 1 µF 至 5 µF CMC 0,38 % 25 kHz 至 30 kHz 1 µF 至 5 µF CMC 0,42 % 30 kHz 至 40 kHz 1 µF 至 5 µF CMC 0,33 % 40 kHz 至 50 kHz 1 µF 至 5 µF CMC 0,38 % 50 kHz 至 60 kHz 1 µF 至 5 µF CMC 0,42 % 60 kHz 至 70 kHz 1 µF 至 5 µF CMC 0,46 % 70 kHz 至 80 kHz 1 µF 至 5 µF CMC 0,51 % 80 kHz 至 90 kHz 1 µF 至 5 µF CMC 0,55 % 90 kHz 至 100 kHz 1 µF 至 5 µF CMC 0,59 % 100 kHz 至 110 kHz 1 µF 至 5 µF CMC 1,1 % 110 kHz 至 140 kHz 1 µF 至 5 µF CMC 1,3 % 140 kHz 至 160 kHz 1 µF 至 5 µF CMC 1,5 % 160 kHz 至 190 kHz 1 µF 至 5 µF CMC 1,7 % 190 kHz 至 210 kHz 1 µF 至 5 µF CMC 1,9 % 210 kHz 至 250 kHz 1 µF 至 5 µF CMC 2,2 % 250 kHz 至 300 kHz 1 µF 至 5 µF CMC 2,6 % 300 kHz 至 350 kHz 1 µF 至 5 µF CMC 4,3 % 350 kHz 至 400 kHz 1 µF 至 5 µF CMC 4,9 % 400 kHz 至 450 kHz 1 µF 至 5 µF CMC 5,4 % 450 kHz 至 500 kHz 1 µF 至 5 µF CMC 6,0 % 20 Hz 至 50 Hz 5 µF 至 10 µF CMC 0,34 % 50 Hz 至 5 kHz 5 µF 至 10 µF CMC 0,20 % 5 kHz 至 10 kHz 5 µF 至 10 µF CMC 0,25 % 10 kHz 至 15 kHz 5 µF 至 10 µF CMC 0,29 % 15 kHz 至 20 kHz 5 µF 至 10 µF CMC 0,33 % 20 kHz 至 25 kHz 5 µF 至 10 µF CMC 0,38 % 25 kHz 至 30 kHz 5 µF 至 10 µF CMC 0,42 % 30 kHz 至 40 kHz 5 µF 至 10 µF CMC 0,51 % 40 kHz 至 50 kHz 5 µF 至 10 µF CMC 0,59 % 50 kHz 至 60 kHz 5 µF 至 10 µF CMC 0,68 % 60 kHz 至 70 kHz 5 µF 至 10 µF CMC 0,77 % 70 kHz 至 80 kHz 5 µF 至 10 µF CMC 0,85 % 80 kHz 至 90 kHz 5 µF 至 10 µF CMC 0,94 % 90 kHz 至 100 kHz 5 µF 至 10 µF CMC 1,1 % 100 kHz 至 110 kHz 5 µF 至 10 µF CMC 2,0 % 110 kHz 至 140 kHz 5 µF 至 10 µF CMC 2,4 % 140 kHz 至 160 kHz 5 µF 至 10 µF CMC 2,8 % 160 kHz 至 190 kHz 5 µF 至 10 µF CMC 3,2 % 190 kHz 至 210 kHz 5 µF 至 10 µF CMC 3,6 % 210 kHz 至 250 kHz 5 µF 至 10 µF CMC 4,2 % 250 kHz 至 300 kHz 5 µF 至 10 µF CMC 5,0 % 20 Hz 至 50 Hz 10 µF 至 20 µF CMC 0,34 % 50 Hz 至 500 Hz 10 µF 至 20 µF CMC 0,20 % 500 Hz 至 700 Hz 10 µF 至 20 µF CMC 0,22 % 700 Hz 至 1 kHz 10 µF 至 20 µF CMC 0,25 % 1 kHz 至 2 kHz 10 µF 至 20 µF CMC 0,33 % 2 kHz 至 3 kHz 10 µF 至 20 µF CMC 0,42 % 3 kHz 至 4 kHz 10 µF 至 20 µF CMC 0,51 % 4 kHz 至 5 kHz 10 µF 至 20 µF CMC 0,59 % 5 kHz 至 6 kHz 10 µF 至 20 µF CMC 0,68 % 6 kHz 至 7 kHz 10 µF 至 20 µF CMC 0,77 % 7 kHz 至 8 kHz 10 µF 至 20 µF CMC 0,85 % 8 kHz 至 9 kHz 10 µF 至 20 µF CMC 0,94 % 9 kHz 至 10 kHz 10 µF 至 20 µF CMC 1,1 % 10 kHz 至 15 kHz 10 µF 至 20 µF CMC 1,5 % 15 kHz 至 20 kHz 10 µF 至 20 µF CMC 1,9 % 20 kHz 至 25 kHz 10 µF 至 20 µF CMC 2,4 % 25 kHz 至 30 kHz 10 µF 至 20 µF CMC 2,8 % 30 kHz 至 40 kHz 10 µF 至 20 µF CMC 1,9 % 40 kHz 至 50 kHz 10 µF 至 20 µF CMC 2,4 % 50 kHz 至 60 kHz 10 µF 至 20 µF CMC 2,8 % 60 kHz 至 70 kHz 10 µF 至 20 µF CMC 3,2 % 70 kHz 至 80 kHz 10 µF 至 20 µF CMC 3,7 % 80 kHz 至 90 kHz 10 µF 至 20 µF CMC 4,1 % 90 kHz 至 100 kHz 10 µF 至 20 µF CMC 4,6 % 20 Hz 至 50 Hz 20 µF 至 50 µF CMC 0,34 % 50 Hz 至 500 Hz 20 µF 至 50 µF CMC 0,20 % 500 Hz 至 700 Hz 20 µF 至 50 µF CMC 0,22 % 700 Hz 至 1 kHz 20 µF 至 50 µF CMC 0,25 % 1 kHz 至 2 kHz 20 µF 至 50 µF CMC 0,33 % 2 kHz 至 3 kHz 20 µF 至 50 µF CMC 0,42 % 3 kHz 至 4 kHz 20 µF 至 50 µF CMC 0,51 % 4 kHz 至 5 kHz 20 µF 至 50 µF CMC 0,59 % 5 kHz 至 6 kHz 20 µF 至 50 µF CMC 0,68 % 6 kHz 至 7 kHz 20 µF 至 50 µF CMC 0,77 % 7 kHz 至 8 kHz 20 µF 至 50 µF CMC 0,85 % 8 kHz 至 9 kHz 20 µF 至 50 µF CMC 0,94 % 9 kHz 至 10 kHz 20 µF 至 50 µF CMC 1,1 % 10 kHz 至 15 kHz 20 µF 至 50 µF CMC 1,5 % 15 kHz 至 20 kHz 20 µF 至 50 µF CMC 1,9 % 20 kHz 至 25 kHz 20 µF 至 50 µF CMC 2,4 % 25 kHz 至 30 kHz 20 µF 至 50 µF CMC 2,8 % 30 kHz 至 40 kHz 20 µF 至 50 µF CMC 1,9 % 40 kHz 至 50 kHz 20 µF 至 50 µF CMC 2,4 % 20 Hz 至 50 Hz 50 µF 至 100 µF CMC 0,34 % 50 Hz 至 500 Hz 50 µF 至 100 µF CMC 0,20 % 500 Hz 至 700 Hz 50 µF 至 100 µF CMC 0,22 % 700 Hz 至 1 kHz 50 µF 至 100 µF CMC 0,25 % 1 kHz 至 2 kHz 50 µF 至 100 µF CMC 0,33 % 2 kHz 至 3 kHz 50 µF 至 100 µF CMC 0,42 % 3 kHz 至 4 kHz 50 µF 至 100 µF CMC 0,51 % 4 kHz 至 5 kHz 50 µF 至 100 µF CMC 0,59 % 5 kHz 至 6 kHz 50 µF 至 100 µF CMC 0,68 % 6 kHz 至 7 kHz 50 µF 至 100 µF CMC 0,77 % 7 kHz 至 8 kHz 50 µF 至 100 µF CMC 0,85 % 8 kHz 至 9 kHz 50 µF 至 100 µF CMC 0,94 % 9 kHz 至 10 kHz 50 µF 至 100 µF CMC 1,1 % 10 kHz 至 15 kHz 50 µF 至 100 µF CMC 1,5 % 15 kHz 至 20 kHz 50 µF 至 100 µF CMC 1,9 % 20 Hz 至 50 Hz 100 µF 至 500 µF CMC 0,44 % 50 Hz 至 70 Hz 100 µF 至 500 µF CMC 0,29 % 70 Hz 至 200 Hz 100 µF 至 500 µF CMC 0,33 % 200 Hz 至 300 Hz 100 µF 至 500 µF CMC 0,42 % 300 Hz 至 400 Hz 100 µF 至 500 µF CMC 0,51 % 400 Hz 至 500 Hz 100 µF 至 500 µF CMC 0,59 % 500 Hz 至 600 Hz 100 µF 至 500 µF CMC 0,68 % 600 Hz 至 700 Hz 100 µF 至 500 µF CMC 0,77 % 700 Hz 至 800 Hz 100 µF 至 500 µF CMC 0,85 % 800 Hz 至 900 Hz 100 µF 至 500 µF CMC 0,94 % 900 Hz 至 2 kHz 100 µF 至 500 µF CMC 1,1 % 2 kHz 至 3 kHz 100 µF 至 500 µF CMC 1,5 % 3 kHz 至 4 kHz 100 µF 至 500 µF CMC 1,9 % 4 kHz 至 5 kHz 100 µF 至 500 µF CMC 2,4 % 20 Hz 至 50 Hz 500 µF 至 1 mF CMC 0,44 % 50 Hz 至 70 Hz 500 µF 至 1 mF CMC 0,29 % 70 Hz 至 200 Hz 500 µF 至 1 mF CMC 0,33 % 200 Hz 至 300 Hz 500 µF 至 1 mF CMC 0,42 % 300 Hz 至 400 Hz 500 µF 至 1 mF CMC 0,51 % 400 Hz 至 500 Hz 500 µF 至 1 mF CMC 0,59 % 500 Hz 至 600 Hz 500 µF 至 1 mF CMC 0,68 % 600 Hz 至 700 Hz 500 µF 至 1 mF CMC 0,77 % 700 Hz 至 800 Hz 500 µF 至 1 mF CMC 0,85 % 800 Hz 至 900 Hz 500 µF 至 1 mF CMC 0,94 % 900 Hz 至 1 kHz 500 µF 至 1 mF CMC 1,1 % 1 kHz 至 2 kHz 500 µF 至 1 mF CMC 1,9 % 20 Hz 至 30 Hz 1 mF 至 5 mF CMC 0,70 % 30 Hz 至 40 Hz 1 mF 至 5 mF CMC 0,78 % 40 Hz 至 80 Hz 1 mF 至 5 mF CMC 0,89 % 80 Hz 至 90 Hz 1 mF 至 5 mF CMC 0,96 % 90 Hz 至 160 Hz 1 mF 至 5 mF CMC 1,1 % 160 Hz 至 300 Hz 1 mF 至 5 mF CMC 1,7 % 300 Hz 至 400 Hz 1 mF 至 5 mF CMC 2,1 % 400 Hz 至 500 Hz 1 mF 至 5 mF CMC 2,6 % 500 Hz 至 600 Hz 1 mF 至 5 mF CMC 3,0 % 600 Hz 至 700 Hz 1 mF 至 5 mF CMC 3,4 % 700 Hz 至 800 Hz 1 mF 至 5 mF CMC 3,9 % 800 Hz 至 900 Hz 1 mF 至 5 mF CMC 4,3 % 900 Hz 至 1 kHz 1 mF 至 5 mF CMC 4,7 % 50 Hz 至 60 Hz 5 mF 至 10 mF CMC 1,4 % 60 Hz 至 160 Hz 5 mF 至 10 mF CMC 1,9 % 160 Hz 至 220 Hz 5 mF 至 10 mF CMC 2,3 % 220 Hz 至 300 Hz 5 mF 至 10 mF CMC 3,0 % TP7, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"713b2b1a0ec0640336014ba1","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"7","test_object":"Pojemność / Mierniki pojemności elektrycznej","test_object_en":"Capacity / Electrical capacity meters","test_object_zh":"电容 / 电容测量仪器","test_object_cs":"Kapacita / Měřidla elektrické kapacity","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"1 pF","cmc":"0,010 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,004 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,009 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,006 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,019 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,053 %"},{"name":"1 kHz","range":"100 µF","cmc":"0,081 %"},{"name":"100 Hz do 1 kHz","range":"1 pF","cmc":"0,019 %"},{"name":"1 kHz do 100 kHz","range":"1 pF","cmc":"0,022 %"},{"name":"100 kHz do 1 MHz","range":"1 pF","cmc":"0,023 %"},{"name":"1 MHz do 10 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"100 Hz do 1 kHz","range":"10 pF","cmc":"0,006 %"},{"name":"1 kHz do 100 kHz","range":"10 pF","cmc":"0,012 %"},{"name":"100 kHz do 1 MHz","range":"10 pF","cmc":"0,050 %"},{"name":"1 MHz do 10 MHz","range":"10 pF","cmc":"0,025 %"},{"name":"100 Hz do 1 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"1 kHz do 100 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"100 kHz do 1 MHz","range":"100 pF","cmc":"0,021 %"},{"name":"1 MHz do 10 MHz","range":"100 pF","cmc":"0,31 %"},{"name":"100 Hz do 1 kHz","range":"1 nF","cmc":"0,006 %"},{"name":"1 kHz do 100 kHz","range":"1 nF","cmc":"0,010 %"},{"name":"100 kHz do 1 MHz","range":"1 nF","cmc":"0,011 %"},{"name":"1 MHz do 10 MHz","range":"1 nF","cmc":"0,64 %"},{"name":"100 Hz do 1 kHz","range":"10 nF","cmc":"0,005 %"},{"name":"1 kHz do 10 kHz","range":"10 nF","cmc":"0,006 %"},{"name":"10 kHz do 100 kHz","range":"10 nF","cmc":"0,010 %"},{"name":"100 Hz do 1 kHz","range":"100 nF","cmc":"0,015 %"},{"name":"1 kHz do 100 kHz","range":"100 nF","cmc":"0,013 %"},{"name":"100 Hz do 1 kHz","range":"1 µF","cmc":"0,024 %"},{"name":"1 kHz do 10 kHz","range":"1 µF","cmc":"0,025 %"},{"name":"10 kHz do 100 kHz","range":"1 µF","cmc":"0,042 %"},{"name":"100 Hz do 1 kHz","range":"10 µF","cmc":"0,054 %"},{"name":"1 kHz do 10 kHz","range":"10 µF","cmc":"0,060 %"},{"name":"10 kHz do 100 kHz","range":"10 µF","cmc":"0,26 %"},{"name":"100 Hz do 1 kHz","range":"100 µF","cmc":"0,25 %"},{"name":"1 kHz do 10 kHz","range":"100 µF","cmc":"0,24 %"},{"name":"10 Hz do 10 kHz","range":"od 220 pF do 1,1 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz do 3 kHz","range":"od 1,1 nF do 3,3 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz do 1 kHz","range":"od 3,3 nF do 11 nF","cmc":"0,25 % + 0,01 nF"},{"name":"10 Hz do 1 kHz","range":"od 11 nF do 110 nF","cmc":"0,25 % + 0,1 nF"},{"name":"10 Hz do 1 kHz","range":"od 110 nF do 330 nF","cmc":"0,25 % + 0,3 nF"},{"name":"10 Hz do 600 Hz","range":"od 0,33 µF do 1,1 µF","cmc":"0,25 % + 1 nF"},{"name":"10 Hz do 300 kHz","range":"od 1,1 µF do 3,3 µF","cmc":"0,25 % + 3 nF"},{"name":"10 Hz do 150 Hz","range":"od 3,3 µF do 11 µF","cmc":"0,25 % + 10 nF"},{"name":"10 Hz do 120 Hz","range":"od 11 µF do 33 µF","cmc":"0,40 % + 30 nF"},{"name":"10 Hz do 80 Hz","range":"od 33 µF do 110 µF","cmc":"0,45 % + 100 nF"},{"name":"0 Hz do 50 Hz","range":"od 110 µF do 330 µF","cmc":"0,45 % + 300 nF"},{"name":"0 Hz do 20 Hz","range":"od 0,33 mF do 1,1 mF","cmc":"0,45 % + 1 µF"},{"name":"0 Hz do 6 Hz","range":"od 1,1 mF do 3,3 mF","cmc":"0,45 % + 3 µF"},{"name":"0 Hz do 2 Hz","range":"od 3,3 mF do 11 mF","cmc":"0,45 % + 10 µF"},{"name":"0 Hz do 0,6 Hz","range":"od 11 mF do 33 mF","cmc":"0,75 % + 30 µF"},{"name":"0 Hz do 0,2 Hz","range":"od 33 mF do 110 mF","cmc":"1 % + 100 µF"}],"parameters_en":[{"name":"1 kHz","range":"1 pF","cmc":"0,010 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,004 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,009 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,006 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,019 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,053 %"},{"name":"1 kHz","range":"100 µF","cmc":"0,081 %"},{"name":"100 Hz to 1 kHz","range":"1 pF","cmc":"0,019 %"},{"name":"1 kHz to 100 kHz","range":"1 pF","cmc":"0,022 %"},{"name":"100 kHz to 1 MHz","range":"1 pF","cmc":"0,023 %"},{"name":"1 MHz to 10 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"100 Hz to 1 kHz","range":"10 pF","cmc":"0,006 %"},{"name":"1 kHz to 100 kHz","range":"10 pF","cmc":"0,012 %"},{"name":"100 kHz to 1 MHz","range":"10 pF","cmc":"0,050 %"},{"name":"1 MHz to 10 MHz","range":"10 pF","cmc":"0,025 %"},{"name":"100 Hz to 1 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"1 kHz to 100 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"100 kHz to 1 MHz","range":"100 pF","cmc":"0,021 %"},{"name":"1 MHz to 10 MHz","range":"100 pF","cmc":"0,31 %"},{"name":"100 Hz to 1 kHz","range":"1 nF","cmc":"0,006 %"},{"name":"1 kHz to 100 kHz","range":"1 nF","cmc":"0,010 %"},{"name":"100 kHz to 1 MHz","range":"1 nF","cmc":"0,011 %"},{"name":"1 MHz to 10 MHz","range":"1 nF","cmc":"0,64 %"},{"name":"100 Hz to 1 kHz","range":"10 nF","cmc":"0,005 %"},{"name":"1 kHz to 10 kHz","range":"10 nF","cmc":"0,006 %"},{"name":"10 kHz to 100 kHz","range":"10 nF","cmc":"0,010 %"},{"name":"100 Hz to 1 kHz","range":"100 nF","cmc":"0,015 %"},{"name":"1 kHz to 100 kHz","range":"100 nF","cmc":"0,013 %"},{"name":"100 Hz to 1 kHz","range":"1 µF","cmc":"0,024 %"},{"name":"1 kHz to 10 kHz","range":"1 µF","cmc":"0,025 %"},{"name":"10 kHz to 100 kHz","range":"1 µF","cmc":"0,042 %"},{"name":"100 Hz to 1 kHz","range":"10 µF","cmc":"0,054 %"},{"name":"1 kHz to 10 kHz","range":"10 µF","cmc":"0,060 %"},{"name":"10 kHz to 100 kHz","range":"10 µF","cmc":"0,26 %"},{"name":"100 Hz to 1 kHz","range":"100 µF","cmc":"0,25 %"},{"name":"1 kHz to 10 kHz","range":"100 µF","cmc":"0,24 %"},{"name":"10 Hz to 10 kHz","range":"220 pF to 1,1 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz to 3 kHz","range":"1,1 nF to 3,3 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz to 1 kHz","range":"3,3 nF to 11 nF","cmc":"0,25 % + 0,01 nF"},{"name":"10 Hz to 1 kHz","range":"11 nF to 110 nF","cmc":"0,25 % + 0,1 nF"},{"name":"10 Hz to 1 kHz","range":"110 nF to 330 nF","cmc":"0,25 % + 0,3 nF"},{"name":"10 Hz to 600 Hz","range":"0,33 µF to 1,1 µF","cmc":"0,25 % + 1 nF"},{"name":"10 Hz to 300 kHz","range":"1,1 µF to 3,3 µF","cmc":"0,25 % + 3 nF"},{"name":"10 Hz to 150 Hz","range":"3,3 µF to 11 µF","cmc":"0,25 % + 10 nF"},{"name":"10 Hz to 120 Hz","range":"11 µF to 33 µF","cmc":"0,40 % + 30 nF"},{"name":"10 Hz to 80 Hz","range":"33 µF to 110 µF","cmc":"0,45 % + 100 nF"},{"name":"0 Hz to 50 Hz","range":"110 µF to 330 µF","cmc":"0,45 % + 300 nF"},{"name":"0 Hz to 20 Hz","range":"0,33 mF to 1,1 mF","cmc":"0,45 % + 1 µF"},{"name":"0 Hz to 6 Hz","range":"1,1 mF to 3,3 mF","cmc":"0,45 % + 3 µF"},{"name":"0 Hz to 2 Hz","range":"3,3 mF to 11 mF","cmc":"0,45 % + 10 µF"},{"name":"0 Hz to 0,6 Hz","range":"11 mF to 33 mF","cmc":"0,75 % + 30 µF"},{"name":"0 Hz to 0,2 Hz","range":"33 mF to 110 mF","cmc":"1 % + 100 µF"}],"parameters_zh":[{"name":"1 kHz","range":"1 pF","cmc":"0,010 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,004 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,009 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,006 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,019 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,053 %"},{"name":"1 kHz","range":"100 µF","cmc":"0,081 %"},{"name":"100 Hz 至 1 kHz","range":"1 pF","cmc":"0,019 %"},{"name":"1 kHz 至 100 kHz","range":"1 pF","cmc":"0,022 %"},{"name":"100 kHz 至 1 MHz","range":"1 pF","cmc":"0,023 %"},{"name":"1 MHz 至 10 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"100 Hz 至 1 kHz","range":"10 pF","cmc":"0,006 %"},{"name":"1 kHz 至 100 kHz","range":"10 pF","cmc":"0,012 %"},{"name":"100 kHz 至 1 MHz","range":"10 pF","cmc":"0,050 %"},{"name":"1 MHz 至 10 MHz","range":"10 pF","cmc":"0,025 %"},{"name":"100 Hz 至 1 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"1 kHz 至 100 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"100 kHz 至 1 MHz","range":"100 pF","cmc":"0,021 %"},{"name":"1 MHz 至 10 MHz","range":"100 pF","cmc":"0,31 %"},{"name":"100 Hz 至 1 kHz","range":"1 nF","cmc":"0,006 %"},{"name":"1 kHz 至 100 kHz","range":"1 nF","cmc":"0,010 %"},{"name":"100 kHz 至 1 MHz","range":"1 nF","cmc":"0,011 %"},{"name":"1 MHz 至 10 MHz","range":"1 nF","cmc":"0,64 %"},{"name":"100 Hz 至 1 kHz","range":"10 nF","cmc":"0,005 %"},{"name":"1 kHz 至 10 kHz","range":"10 nF","cmc":"0,006 %"},{"name":"10 kHz 至 100 kHz","range":"10 nF","cmc":"0,010 %"},{"name":"100 Hz 至 1 kHz","range":"100 nF","cmc":"0,015 %"},{"name":"1 kHz 至 100 kHz","range":"100 nF","cmc":"0,013 %"},{"name":"100 Hz 至 1 kHz","range":"1 µF","cmc":"0,024 %"},{"name":"1 kHz 至 10 kHz","range":"1 µF","cmc":"0,025 %"},{"name":"10 kHz 至 100 kHz","range":"1 µF","cmc":"0,042 %"},{"name":"100 Hz 至 1 kHz","range":"10 µF","cmc":"0,054 %"},{"name":"1 kHz 至 10 kHz","range":"10 µF","cmc":"0,060 %"},{"name":"10 kHz 至 100 kHz","range":"10 µF","cmc":"0,26 %"},{"name":"100 Hz 至 1 kHz","range":"100 µF","cmc":"0,25 %"},{"name":"1 kHz 至 10 kHz","range":"100 µF","cmc":"0,24 %"},{"name":"10 Hz 至 10 kHz","range":"220 pF 至 1,1 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz 至 3 kHz","range":"1,1 nF 至 3,3 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz 至 1 kHz","range":"3,3 nF 至 11 nF","cmc":"0,25 % + 0,01 nF"},{"name":"10 Hz 至 1 kHz","range":"11 nF 至 110 nF","cmc":"0,25 % + 0,1 nF"},{"name":"10 Hz 至 1 kHz","range":"110 nF 至 330 nF","cmc":"0,25 % + 0,3 nF"},{"name":"10 Hz 至 600 Hz","range":"0,33 µF 至 1,1 µF","cmc":"0,25 % + 1 nF"},{"name":"10 Hz 至 300 kHz","range":"1,1 µF 至 3,3 µF","cmc":"0,25 % + 3 nF"},{"name":"10 Hz 至 150 Hz","range":"3,3 µF 至 11 µF","cmc":"0,25 % + 10 nF"},{"name":"10 Hz 至 120 Hz","range":"11 µF 至 33 µF","cmc":"0,40 % + 30 nF"},{"name":"10 Hz 至 80 Hz","range":"33 µF 至 110 µF","cmc":"0,45 % + 100 nF"},{"name":"0 Hz 至 50 Hz","range":"110 µF 至 330 µF","cmc":"0,45 % + 300 nF"},{"name":"0 Hz 至 20 Hz","range":"0,33 mF 至 1,1 mF","cmc":"0,45 % + 1 µF"},{"name":"0 Hz 至 6 Hz","range":"1,1 mF 至 3,3 mF","cmc":"0,45 % + 3 µF"},{"name":"0 Hz 至 2 Hz","range":"3,3 mF 至 11 mF","cmc":"0,45 % + 10 µF"},{"name":"0 Hz 至 0,6 Hz","range":"11 mF 至 33 mF","cmc":"0,75 % + 30 µF"},{"name":"0 Hz 至 0,2 Hz","range":"33 mF 至 110 mF","cmc":"1 % + 100 µF"}],"parameters_cs":[{"name":"1 kHz","range":"1 pF","cmc":"0,010 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,004 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,009 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,003 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,006 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,019 %"},{"name":"1 kHz","range":"10 µF","cmc":"0,053 %"},{"name":"1 kHz","range":"100 µF","cmc":"0,081 %"},{"name":"100 Hz až 1 kHz","range":"1 pF","cmc":"0,019 %"},{"name":"1 kHz až 100 kHz","range":"1 pF","cmc":"0,022 %"},{"name":"100 kHz až 1 MHz","range":"1 pF","cmc":"0,023 %"},{"name":"1 MHz až 10 MHz","range":"1 pF","cmc":"0,10 %"},{"name":"100 Hz až 1 kHz","range":"10 pF","cmc":"0,006 %"},{"name":"1 kHz až 100 kHz","range":"10 pF","cmc":"0,012 %"},{"name":"100 kHz až 1 MHz","range":"10 pF","cmc":"0,050 %"},{"name":"1 MHz až 10 MHz","range":"10 pF","cmc":"0,025 %"},{"name":"100 Hz až 1 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"1 kHz až 100 kHz","range":"100 pF","cmc":"0,011 %"},{"name":"100 kHz až 1 MHz","range":"100 pF","cmc":"0,021 %"},{"name":"1 MHz až 10 MHz","range":"100 pF","cmc":"0,31 %"},{"name":"100 Hz až 1 kHz","range":"1 nF","cmc":"0,006 %"},{"name":"1 kHz až 100 kHz","range":"1 nF","cmc":"0,010 %"},{"name":"100 kHz až 1 MHz","range":"1 nF","cmc":"0,011 %"},{"name":"1 MHz až 10 MHz","range":"1 nF","cmc":"0,64 %"},{"name":"100 Hz až 1 kHz","range":"10 nF","cmc":"0,005 %"},{"name":"1 kHz až 10 kHz","range":"10 nF","cmc":"0,006 %"},{"name":"10 kHz až 100 kHz","range":"10 nF","cmc":"0,010 %"},{"name":"100 Hz až 1 kHz","range":"100 nF","cmc":"0,015 %"},{"name":"1 kHz až 100 kHz","range":"100 nF","cmc":"0,013 %"},{"name":"100 Hz až 1 kHz","range":"1 µF","cmc":"0,024 %"},{"name":"1 kHz až 10 kHz","range":"1 µF","cmc":"0,025 %"},{"name":"10 kHz až 100 kHz","range":"1 µF","cmc":"0,042 %"},{"name":"100 Hz až 1 kHz","range":"10 µF","cmc":"0,054 %"},{"name":"1 kHz až 10 kHz","range":"10 µF","cmc":"0,060 %"},{"name":"10 kHz až 100 kHz","range":"10 µF","cmc":"0,26 %"},{"name":"100 Hz až 1 kHz","range":"100 µF","cmc":"0,25 %"},{"name":"1 kHz až 10 kHz","range":"100 µF","cmc":"0,24 %"},{"name":"10 Hz až 10 kHz","range":"220 pF až 1,1 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz až 3 kHz","range":"1,1 nF až 3,3 nF","cmc":"0,5 % + 0,01 nF"},{"name":"10 Hz až 1 kHz","range":"3,3 nF až 11 nF","cmc":"0,25 % + 0,01 nF"},{"name":"10 Hz až 1 kHz","range":"11 nF až 110 nF","cmc":"0,25 % + 0,1 nF"},{"name":"10 Hz až 1 kHz","range":"110 nF až 330 nF","cmc":"0,25 % + 0,3 nF"},{"name":"10 Hz až 600 Hz","range":"0,33 µF až 1,1 µF","cmc":"0,25 % + 1 nF"},{"name":"10 Hz až 300 kHz","range":"1,1 µF až 3,3 µF","cmc":"0,25 % + 3 nF"},{"name":"10 Hz až 150 Hz","range":"3,3 µF až 11 µF","cmc":"0,25 % + 10 nF"},{"name":"10 Hz až 120 Hz","range":"11 µF až 33 µF","cmc":"0,40 % + 30 nF"},{"name":"10 Hz až 80 Hz","range":"33 µF až 110 µF","cmc":"0,45 % + 100 nF"},{"name":"0 Hz až 50 Hz","range":"110 µF až 330 µF","cmc":"0,45 % + 300 nF"},{"name":"0 Hz až 20 Hz","range":"0,33 mF až 1,1 mF","cmc":"0,45 % + 1 µF"},{"name":"0 Hz až 6 Hz","range":"1,1 mF až 3,3 mF","cmc":"0,45 % + 3 µF"},{"name":"0 Hz až 2 Hz","range":"3,3 mF až 11 mF","cmc":"0,45 % + 10 µF"},{"name":"0 Hz až 0,6 Hz","range":"11 mF až 33 mF","cmc":"0,75 % + 30 µF"},{"name":"0 Hz až 0,2 Hz","range":"33 mF až 110 mF","cmc":"1 % + 100 µF"}],"technique":"Pomiar bezpośredni wzorca pojemności","technique_en":"Direct measurement of a capacity standard","technique_zh":"直接测量电容标准器","technique_cs":"Přímé měření etalonu kapacity","techniques":["Pomiar bezpośredni wzorca pojemności"],"techniques_en":["Direct measurement of a capacity standard"],"techniques_zh":["直接测量电容标准器"],"techniques_cs":["Přímé měření etalonu kapacity"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz 1 pF CMC 0,010 %\n1 kHz 10 pF CMC 0,004 %\n1 kHz 100 pF CMC 0,009 %\n1 kHz 1 nF CMC 0,003 %\n1 kHz 10 nF CMC 0,003 %\n1 kHz 100 nF CMC 0,006 %\n1 kHz 1 µF CMC 0,019 %\n1 kHz 10 µF CMC 0,053 %\n1 kHz 100 µF CMC 0,081 %\n100 Hz do 1 kHz 1 pF CMC 0,019 %\n1 kHz do 100 kHz 1 pF CMC 0,022 %\n100 kHz do 1 MHz 1 pF CMC 0,023 %\n1 MHz do 10 MHz 1 pF CMC 0,10 %\n100 Hz do 1 kHz 10 pF CMC 0,006 %\n1 kHz do 100 kHz 10 pF CMC 0,012 %\n100 kHz do 1 MHz 10 pF CMC 0,050 %\n1 MHz do 10 MHz 10 pF CMC 0,025 %\n100 Hz do 1 kHz 100 pF CMC 0,011 %\n1 kHz do 100 kHz 100 pF CMC 0,011 %\n100 kHz do 1 MHz 100 pF CMC 0,021 %\n1 MHz do 10 MHz 100 pF CMC 0,31 %\n100 Hz do 1 kHz 1 nF CMC 0,006 %\n1 kHz do 100 kHz 1 nF CMC 0,010 %\n100 kHz do 1 MHz 1 nF CMC 0,011 %\n1 MHz do 10 MHz 1 nF CMC 0,64 %\n100 Hz do 1 kHz 10 nF CMC 0,005 %\n1 kHz do 10 kHz 10 nF CMC 0,006 %\n10 kHz do 100 kHz 10 nF CMC 0,010 %\n100 Hz do 1 kHz 100 nF CMC 0,015 %\n1 kHz do 100 kHz 100 nF CMC 0,013 %\n100 Hz do 1 kHz 1 µF CMC 0,024 %\n1 kHz do 10 kHz 1 µF CMC 0,025 %\n10 kHz do 100 kHz 1 µF CMC 0,042 %\n100 Hz do 1 kHz 10 µF CMC 0,054 %\n1 kHz do 10 kHz 10 µF CMC 0,060 %\n10 kHz do 100 kHz 10 µF CMC 0,26 %\n100 Hz do 1 kHz 100 µF CMC 0,25 %\n1 kHz do 10 kHz 100 µF CMC 0,24 %\n10 Hz do 10 kHz od 220 pF do 1,1 nF CMC 0,5 % + 0,01 nF\n10 Hz do 3 kHz od 1,1 nF do 3,3 nF CMC 0,5 % + 0,01 nF\n10 Hz do 1 kHz od 3,3 nF do 11 nF CMC 0,25 % + 0,01 nF\n10 Hz do 1 kHz od 11 nF do 110 nF CMC 0,25 % + 0,1 nF\n10 Hz do 1 kHz od 110 nF do 330 nF CMC 0,25 % + 0,3 nF\n10 Hz do 600 Hz od 0,33 µF do 1,1 µF CMC 0,25 % + 1 nF\n10 Hz do 300 kHz od 1,1 µF do 3,3 µF CMC 0,25 % + 3 nF\n10 Hz do 150 Hz od 3,3 µF do 11 µF CMC 0,25 % + 10 nF\n10 Hz do 120 Hz od 11 µF do 33 µF CMC 0,40 % + 30 nF\n10 Hz do 80 Hz od 33 µF do 110 µF CMC 0,45 % + 100 nF\n0 Hz do 50 Hz od 110 µF do 330 µF CMC 0,45 % + 300 nF\n0 Hz do 20 Hz od 0,33 mF do 1,1 mF CMC 0,45 % + 1 µF\n0 Hz do 6 Hz od 1,1 mF do 3,3 mF CMC 0,45 % + 3 µF\n0 Hz do 2 Hz od 3,3 mF do 11 mF CMC 0,45 % + 10 µF\n0 Hz do 0,6 Hz od 11 mF do 33 mF CMC 0,75 % + 30 µF\n0 Hz do 0,2 Hz od 33 mF do 110 mF CMC 1 % + 100 µF\nPomiar bezpośredni wzorca pojemności","reference":"TP7, TP21, TP24","norm_bases":["TP7","TP21","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / Mierniki pojemności elektrycznej Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorca pojemności 1 kHz 1 pF CMC 0,010 % 1 kHz 10 pF CMC 0,004 % 1 kHz 100 pF CMC 0,009 % 1 kHz 1 nF CMC 0,003 % 1 kHz 10 nF CMC 0,003 % 1 kHz 100 nF CMC 0,006 % 1 kHz 1 µF CMC 0,019 % 1 kHz 10 µF CMC 0,053 % 1 kHz 100 µF CMC 0,081 % 100 Hz do 1 kHz 1 pF CMC 0,019 % 1 kHz do 100 kHz 1 pF CMC 0,022 % 100 kHz do 1 MHz 1 pF CMC 0,023 % 1 MHz do 10 MHz 1 pF CMC 0,10 % 100 Hz do 1 kHz 10 pF CMC 0,006 % 1 kHz do 100 kHz 10 pF CMC 0,012 % 100 kHz do 1 MHz 10 pF CMC 0,050 % 1 MHz do 10 MHz 10 pF CMC 0,025 % 100 Hz do 1 kHz 100 pF CMC 0,011 % 1 kHz do 100 kHz 100 pF CMC 0,011 % 100 kHz do 1 MHz 100 pF CMC 0,021 % 1 MHz do 10 MHz 100 pF CMC 0,31 % 100 Hz do 1 kHz 1 nF CMC 0,006 % 1 kHz do 100 kHz 1 nF CMC 0,010 % 100 kHz do 1 MHz 1 nF CMC 0,011 % 1 MHz do 10 MHz 1 nF CMC 0,64 % 100 Hz do 1 kHz 10 nF CMC 0,005 % 1 kHz do 10 kHz 10 nF CMC 0,006 % 10 kHz do 100 kHz 10 nF CMC 0,010 % 100 Hz do 1 kHz 100 nF CMC 0,015 % 1 kHz do 100 kHz 100 nF CMC 0,013 % 100 Hz do 1 kHz 1 µF CMC 0,024 % 1 kHz do 10 kHz 1 µF CMC 0,025 % 10 kHz do 100 kHz 1 µF CMC 0,042 % 100 Hz do 1 kHz 10 µF CMC 0,054 % 1 kHz do 10 kHz 10 µF CMC 0,060 % 10 kHz do 100 kHz 10 µF CMC 0,26 % 100 Hz do 1 kHz 100 µF CMC 0,25 % 1 kHz do 10 kHz 100 µF CMC 0,24 % 10 Hz do 10 kHz od 220 pF do 1,1 nF CMC 0,5 % + 0,01 nF 10 Hz do 3 kHz od 1,1 nF do 3,3 nF CMC 0,5 % + 0,01 nF 10 Hz do 1 kHz od 3,3 nF do 11 nF CMC 0,25 % + 0,01 nF 10 Hz do 1 kHz od 11 nF do 110 nF CMC 0,25 % + 0,1 nF 10 Hz do 1 kHz od 110 nF do 330 nF CMC 0,25 % + 0,3 nF 10 Hz do 600 Hz od 0,33 µF do 1,1 µF CMC 0,25 % + 1 nF 10 Hz do 300 kHz od 1,1 µF do 3,3 µF CMC 0,25 % + 3 nF 10 Hz do 150 Hz od 3,3 µF do 11 µF CMC 0,25 % + 10 nF 10 Hz do 120 Hz od 11 µF do 33 µF CMC 0,40 % + 30 nF 10 Hz do 80 Hz od 33 µF do 110 µF CMC 0,45 % + 100 nF 0 Hz do 50 Hz od 110 µF do 330 µF CMC 0,45 % + 300 nF 0 Hz do 20 Hz od 0,33 mF do 1,1 mF CMC 0,45 % + 1 µF 0 Hz do 6 Hz od 1,1 mF do 3,3 mF CMC 0,45 % + 3 µF 0 Hz do 2 Hz od 3,3 mF do 11 mF CMC 0,45 % + 10 µF 0 Hz do 0,6 Hz od 11 mF do 33 mF CMC 0,75 % + 30 µF 0 Hz do 0,2 Hz od 33 mF do 110 mF CMC 1 % + 100 µF Kapacita / Měřidla elektrické kapacity Kalibrace – elektrické veličiny Přímé měření etalonu kapacity 1 kHz 1 pF CMC 0,010 % 1 kHz 10 pF CMC 0,004 % 1 kHz 100 pF CMC 0,009 % 1 kHz 1 nF CMC 0,003 % 1 kHz 10 nF CMC 0,003 % 1 kHz 100 nF CMC 0,006 % 1 kHz 1 µF CMC 0,019 % 1 kHz 10 µF CMC 0,053 % 1 kHz 100 µF CMC 0,081 % 100 Hz až 1 kHz 1 pF CMC 0,019 % 1 kHz až 100 kHz 1 pF CMC 0,022 % 100 kHz až 1 MHz 1 pF CMC 0,023 % 1 MHz až 10 MHz 1 pF CMC 0,10 % 100 Hz až 1 kHz 10 pF CMC 0,006 % 1 kHz až 100 kHz 10 pF CMC 0,012 % 100 kHz až 1 MHz 10 pF CMC 0,050 % 1 MHz až 10 MHz 10 pF CMC 0,025 % 100 Hz až 1 kHz 100 pF CMC 0,011 % 1 kHz až 100 kHz 100 pF CMC 0,011 % 100 kHz až 1 MHz 100 pF CMC 0,021 % 1 MHz až 10 MHz 100 pF CMC 0,31 % 100 Hz až 1 kHz 1 nF CMC 0,006 % 1 kHz až 100 kHz 1 nF CMC 0,010 % 100 kHz až 1 MHz 1 nF CMC 0,011 % 1 MHz až 10 MHz 1 nF CMC 0,64 % 100 Hz až 1 kHz 10 nF CMC 0,005 % 1 kHz až 10 kHz 10 nF CMC 0,006 % 10 kHz až 100 kHz 10 nF CMC 0,010 % 100 Hz až 1 kHz 100 nF CMC 0,015 % 1 kHz až 100 kHz 100 nF CMC 0,013 % 100 Hz až 1 kHz 1 µF CMC 0,024 % 1 kHz až 10 kHz 1 µF CMC 0,025 % 10 kHz až 100 kHz 1 µF CMC 0,042 % 100 Hz až 1 kHz 10 µF CMC 0,054 % 1 kHz až 10 kHz 10 µF CMC 0,060 % 10 kHz až 100 kHz 10 µF CMC 0,26 % 100 Hz až 1 kHz 100 µF CMC 0,25 % 1 kHz až 10 kHz 100 µF CMC 0,24 % 10 Hz až 10 kHz 220 pF až 1,1 nF CMC 0,5 % + 0,01 nF 10 Hz až 3 kHz 1,1 nF až 3,3 nF CMC 0,5 % + 0,01 nF 10 Hz až 1 kHz 3,3 nF až 11 nF CMC 0,25 % + 0,01 nF 10 Hz až 1 kHz 11 nF až 110 nF CMC 0,25 % + 0,1 nF 10 Hz až 1 kHz 110 nF až 330 nF CMC 0,25 % + 0,3 nF 10 Hz až 600 Hz 0,33 µF až 1,1 µF CMC 0,25 % + 1 nF 10 Hz až 300 kHz 1,1 µF až 3,3 µF CMC 0,25 % + 3 nF 10 Hz až 150 Hz 3,3 µF až 11 µF CMC 0,25 % + 10 nF 10 Hz až 120 Hz 11 µF až 33 µF CMC 0,40 % + 30 nF 10 Hz až 80 Hz 33 µF až 110 µF CMC 0,45 % + 100 nF 0 Hz až 50 Hz 110 µF až 330 µF CMC 0,45 % + 300 nF 0 Hz až 20 Hz 0,33 mF až 1,1 mF CMC 0,45 % + 1 µF 0 Hz až 6 Hz 1,1 mF až 3,3 mF CMC 0,45 % + 3 µF 0 Hz až 2 Hz 3,3 mF až 11 mF CMC 0,45 % + 10 µF 0 Hz až 0,6 Hz 11 mF až 33 mF CMC 0,75 % + 30 µF 0 Hz až 0,2 Hz 33 mF až 110 mF CMC 1 % + 100 µF TP7, TP21, TP24 Pojemnosc / Mierniki pojemnosci elektrycznej Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorca pojemnosci 1 kHz 1 pF CMC 0,010 % 1 kHz 10 pF CMC 0,004 % 1 kHz 100 pF CMC 0,009 % 1 kHz 1 nF CMC 0,003 % 1 kHz 10 nF CMC 0,003 % 1 kHz 100 nF CMC 0,006 % 1 kHz 1 µF CMC 0,019 % 1 kHz 10 µF CMC 0,053 % 1 kHz 100 µF CMC 0,081 % 100 Hz do 1 kHz 1 pF CMC 0,019 % 1 kHz do 100 kHz 1 pF CMC 0,022 % 100 kHz do 1 MHz 1 pF CMC 0,023 % 1 MHz do 10 MHz 1 pF CMC 0,10 % 100 Hz do 1 kHz 10 pF CMC 0,006 % 1 kHz do 100 kHz 10 pF CMC 0,012 % 100 kHz do 1 MHz 10 pF CMC 0,050 % 1 MHz do 10 MHz 10 pF CMC 0,025 % 100 Hz do 1 kHz 100 pF CMC 0,011 % 1 kHz do 100 kHz 100 pF CMC 0,011 % 100 kHz do 1 MHz 100 pF CMC 0,021 % 1 MHz do 10 MHz 100 pF CMC 0,31 % 100 Hz do 1 kHz 1 nF CMC 0,006 % 1 kHz do 100 kHz 1 nF CMC 0,010 % 100 kHz do 1 MHz 1 nF CMC 0,011 % 1 MHz do 10 MHz 1 nF CMC 0,64 % 100 Hz do 1 kHz 10 nF CMC 0,005 % 1 kHz do 10 kHz 10 nF CMC 0,006 % 10 kHz do 100 kHz 10 nF CMC 0,010 % 100 Hz do 1 kHz 100 nF CMC 0,015 % 1 kHz do 100 kHz 100 nF CMC 0,013 % 100 Hz do 1 kHz 1 µF CMC 0,024 % 1 kHz do 10 kHz 1 µF CMC 0,025 % 10 kHz do 100 kHz 1 µF CMC 0,042 % 100 Hz do 1 kHz 10 µF CMC 0,054 % 1 kHz do 10 kHz 10 µF CMC 0,060 % 10 kHz do 100 kHz 10 µF CMC 0,26 % 100 Hz do 1 kHz 100 µF CMC 0,25 % 1 kHz do 10 kHz 100 µF CMC 0,24 % 10 Hz do 10 kHz od 220 pF do 1,1 nF CMC 0,5 % + 0,01 nF 10 Hz do 3 kHz od 1,1 nF do 3,3 nF CMC 0,5 % + 0,01 nF 10 Hz do 1 kHz od 3,3 nF do 11 nF CMC 0,25 % + 0,01 nF 10 Hz do 1 kHz od 11 nF do 110 nF CMC 0,25 % + 0,1 nF 10 Hz do 1 kHz od 110 nF do 330 nF CMC 0,25 % + 0,3 nF 10 Hz do 600 Hz od 0,33 µF do 1,1 µF CMC 0,25 % + 1 nF 10 Hz do 300 kHz od 1,1 µF do 3,3 µF CMC 0,25 % + 3 nF 10 Hz do 150 Hz od 3,3 µF do 11 µF CMC 0,25 % + 10 nF 10 Hz do 120 Hz od 11 µF do 33 µF CMC 0,40 % + 30 nF 10 Hz do 80 Hz od 33 µF do 110 µF CMC 0,45 % + 100 nF 0 Hz do 50 Hz od 110 µF do 330 µF CMC 0,45 % + 300 nF 0 Hz do 20 Hz od 0,33 mF do 1,1 mF CMC 0,45 % + 1 µF 0 Hz do 6 Hz od 1,1 mF do 3,3 mF CMC 0,45 % + 3 µF 0 Hz do 2 Hz od 3,3 mF do 11 mF CMC 0,45 % + 10 µF 0 Hz do 0,6 Hz od 11 mF do 33 mF CMC 0,75 % + 30 µF 0 Hz do 0,2 Hz od 33 mF do 110 mF CMC 1 % + 100 µF Kapacita / Meridla elektricke kapacity Kalibrace – elektricke veliciny Prime mereni etalonu kapacity 1 kHz 1 pF CMC 0,010 % 1 kHz 10 pF CMC 0,004 % 1 kHz 100 pF CMC 0,009 % 1 kHz 1 nF CMC 0,003 % 1 kHz 10 nF CMC 0,003 % 1 kHz 100 nF CMC 0,006 % 1 kHz 1 µF CMC 0,019 % 1 kHz 10 µF CMC 0,053 % 1 kHz 100 µF CMC 0,081 % 100 Hz az 1 kHz 1 pF CMC 0,019 % 1 kHz az 100 kHz 1 pF CMC 0,022 % 100 kHz az 1 MHz 1 pF CMC 0,023 % 1 MHz az 10 MHz 1 pF CMC 0,10 % 100 Hz az 1 kHz 10 pF CMC 0,006 % 1 kHz az 100 kHz 10 pF CMC 0,012 % 100 kHz az 1 MHz 10 pF CMC 0,050 % 1 MHz az 10 MHz 10 pF CMC 0,025 % 100 Hz az 1 kHz 100 pF CMC 0,011 % 1 kHz az 100 kHz 100 pF CMC 0,011 % 100 kHz az 1 MHz 100 pF CMC 0,021 % 1 MHz az 10 MHz 100 pF CMC 0,31 % 100 Hz az 1 kHz 1 nF CMC 0,006 % 1 kHz az 100 kHz 1 nF CMC 0,010 % 100 kHz az 1 MHz 1 nF CMC 0,011 % 1 MHz az 10 MHz 1 nF CMC 0,64 % 100 Hz az 1 kHz 10 nF CMC 0,005 % 1 kHz az 10 kHz 10 nF CMC 0,006 % 10 kHz az 100 kHz 10 nF CMC 0,010 % 100 Hz az 1 kHz 100 nF CMC 0,015 % 1 kHz az 100 kHz 100 nF CMC 0,013 % 100 Hz az 1 kHz 1 µF CMC 0,024 % 1 kHz az 10 kHz 1 µF CMC 0,025 % 10 kHz az 100 kHz 1 µF CMC 0,042 % 100 Hz az 1 kHz 10 µF CMC 0,054 % 1 kHz az 10 kHz 10 µF CMC 0,060 % 10 kHz az 100 kHz 10 µF CMC 0,26 % 100 Hz az 1 kHz 100 µF CMC 0,25 % 1 kHz az 10 kHz 100 µF CMC 0,24 % 10 Hz az 10 kHz 220 pF az 1,1 nF CMC 0,5 % + 0,01 nF 10 Hz az 3 kHz 1,1 nF az 3,3 nF CMC 0,5 % + 0,01 nF 10 Hz az 1 kHz 3,3 nF az 11 nF CMC 0,25 % + 0,01 nF 10 Hz az 1 kHz 11 nF az 110 nF CMC 0,25 % + 0,1 nF 10 Hz az 1 kHz 110 nF az 330 nF CMC 0,25 % + 0,3 nF 10 Hz az 600 Hz 0,33 µF az 1,1 µF CMC 0,25 % + 1 nF 10 Hz az 300 kHz 1,1 µF az 3,3 µF CMC 0,25 % + 3 nF 10 Hz az 150 Hz 3,3 µF az 11 µF CMC 0,25 % + 10 nF 10 Hz az 120 Hz 11 µF az 33 µF CMC 0,40 % + 30 nF 10 Hz az 80 Hz 33 µF az 110 µF CMC 0,45 % + 100 nF 0 Hz az 50 Hz 110 µF az 330 µF CMC 0,45 % + 300 nF 0 Hz az 20 Hz 0,33 mF az 1,1 mF CMC 0,45 % + 1 µF 0 Hz az 6 Hz 1,1 mF az 3,3 mF CMC 0,45 % + 3 µF 0 Hz az 2 Hz 3,3 mF az 11 mF CMC 0,45 % + 10 µF 0 Hz az 0,6 Hz 11 mF az 33 mF CMC 0,75 % + 30 µF 0 Hz az 0,2 Hz 33 mF az 110 mF CMC 1 % + 100 µF TP7, TP21, TP24","search_en":"Capacity / Electrical capacity meters Calibration – electrical quantities Direct measurement of a capacity standard 1 kHz 1 pF CMC 0,010 % 1 kHz 10 pF CMC 0,004 % 1 kHz 100 pF CMC 0,009 % 1 kHz 1 nF CMC 0,003 % 1 kHz 10 nF CMC 0,003 % 1 kHz 100 nF CMC 0,006 % 1 kHz 1 µF CMC 0,019 % 1 kHz 10 µF CMC 0,053 % 1 kHz 100 µF CMC 0,081 % 100 Hz to 1 kHz 1 pF CMC 0,019 % 1 kHz to 100 kHz 1 pF CMC 0,022 % 100 kHz to 1 MHz 1 pF CMC 0,023 % 1 MHz to 10 MHz 1 pF CMC 0,10 % 100 Hz to 1 kHz 10 pF CMC 0,006 % 1 kHz to 100 kHz 10 pF CMC 0,012 % 100 kHz to 1 MHz 10 pF CMC 0,050 % 1 MHz to 10 MHz 10 pF CMC 0,025 % 100 Hz to 1 kHz 100 pF CMC 0,011 % 1 kHz to 100 kHz 100 pF CMC 0,011 % 100 kHz to 1 MHz 100 pF CMC 0,021 % 1 MHz to 10 MHz 100 pF CMC 0,31 % 100 Hz to 1 kHz 1 nF CMC 0,006 % 1 kHz to 100 kHz 1 nF CMC 0,010 % 100 kHz to 1 MHz 1 nF CMC 0,011 % 1 MHz to 10 MHz 1 nF CMC 0,64 % 100 Hz to 1 kHz 10 nF CMC 0,005 % 1 kHz to 10 kHz 10 nF CMC 0,006 % 10 kHz to 100 kHz 10 nF CMC 0,010 % 100 Hz to 1 kHz 100 nF CMC 0,015 % 1 kHz to 100 kHz 100 nF CMC 0,013 % 100 Hz to 1 kHz 1 µF CMC 0,024 % 1 kHz to 10 kHz 1 µF CMC 0,025 % 10 kHz to 100 kHz 1 µF CMC 0,042 % 100 Hz to 1 kHz 10 µF CMC 0,054 % 1 kHz to 10 kHz 10 µF CMC 0,060 % 10 kHz to 100 kHz 10 µF CMC 0,26 % 100 Hz to 1 kHz 100 µF CMC 0,25 % 1 kHz to 10 kHz 100 µF CMC 0,24 % 10 Hz to 10 kHz 220 pF to 1,1 nF CMC 0,5 % + 0,01 nF 10 Hz to 3 kHz 1,1 nF to 3,3 nF CMC 0,5 % + 0,01 nF 10 Hz to 1 kHz 3,3 nF to 11 nF CMC 0,25 % + 0,01 nF 10 Hz to 1 kHz 11 nF to 110 nF CMC 0,25 % + 0,1 nF 10 Hz to 1 kHz 110 nF to 330 nF CMC 0,25 % + 0,3 nF 10 Hz to 600 Hz 0,33 µF to 1,1 µF CMC 0,25 % + 1 nF 10 Hz to 300 kHz 1,1 µF to 3,3 µF CMC 0,25 % + 3 nF 10 Hz to 150 Hz 3,3 µF to 11 µF CMC 0,25 % + 10 nF 10 Hz to 120 Hz 11 µF to 33 µF CMC 0,40 % + 30 nF 10 Hz to 80 Hz 33 µF to 110 µF CMC 0,45 % + 100 nF 0 Hz to 50 Hz 110 µF to 330 µF CMC 0,45 % + 300 nF 0 Hz to 20 Hz 0,33 mF to 1,1 mF CMC 0,45 % + 1 µF 0 Hz to 6 Hz 1,1 mF to 3,3 mF CMC 0,45 % + 3 µF 0 Hz to 2 Hz 3,3 mF to 11 mF CMC 0,45 % + 10 µF 0 Hz to 0,6 Hz 11 mF to 33 mF CMC 0,75 % + 30 µF 0 Hz to 0,2 Hz 33 mF to 110 mF CMC 1 % + 100 µF TP7, TP21, TP24","search_zh":"电容 / 电容测量仪器 校准 – 电学量 直接测量电容标准器 1 kHz 1 pF CMC 0,010 % 1 kHz 10 pF CMC 0,004 % 1 kHz 100 pF CMC 0,009 % 1 kHz 1 nF CMC 0,003 % 1 kHz 10 nF CMC 0,003 % 1 kHz 100 nF CMC 0,006 % 1 kHz 1 µF CMC 0,019 % 1 kHz 10 µF CMC 0,053 % 1 kHz 100 µF CMC 0,081 % 100 Hz 至 1 kHz 1 pF CMC 0,019 % 1 kHz 至 100 kHz 1 pF CMC 0,022 % 100 kHz 至 1 MHz 1 pF CMC 0,023 % 1 MHz 至 10 MHz 1 pF CMC 0,10 % 100 Hz 至 1 kHz 10 pF CMC 0,006 % 1 kHz 至 100 kHz 10 pF CMC 0,012 % 100 kHz 至 1 MHz 10 pF CMC 0,050 % 1 MHz 至 10 MHz 10 pF CMC 0,025 % 100 Hz 至 1 kHz 100 pF CMC 0,011 % 1 kHz 至 100 kHz 100 pF CMC 0,011 % 100 kHz 至 1 MHz 100 pF CMC 0,021 % 1 MHz 至 10 MHz 100 pF CMC 0,31 % 100 Hz 至 1 kHz 1 nF CMC 0,006 % 1 kHz 至 100 kHz 1 nF CMC 0,010 % 100 kHz 至 1 MHz 1 nF CMC 0,011 % 1 MHz 至 10 MHz 1 nF CMC 0,64 % 100 Hz 至 1 kHz 10 nF CMC 0,005 % 1 kHz 至 10 kHz 10 nF CMC 0,006 % 10 kHz 至 100 kHz 10 nF CMC 0,010 % 100 Hz 至 1 kHz 100 nF CMC 0,015 % 1 kHz 至 100 kHz 100 nF CMC 0,013 % 100 Hz 至 1 kHz 1 µF CMC 0,024 % 1 kHz 至 10 kHz 1 µF CMC 0,025 % 10 kHz 至 100 kHz 1 µF CMC 0,042 % 100 Hz 至 1 kHz 10 µF CMC 0,054 % 1 kHz 至 10 kHz 10 µF CMC 0,060 % 10 kHz 至 100 kHz 10 µF CMC 0,26 % 100 Hz 至 1 kHz 100 µF CMC 0,25 % 1 kHz 至 10 kHz 100 µF CMC 0,24 % 10 Hz 至 10 kHz 220 pF 至 1,1 nF CMC 0,5 % + 0,01 nF 10 Hz 至 3 kHz 1,1 nF 至 3,3 nF CMC 0,5 % + 0,01 nF 10 Hz 至 1 kHz 3,3 nF 至 11 nF CMC 0,25 % + 0,01 nF 10 Hz 至 1 kHz 11 nF 至 110 nF CMC 0,25 % + 0,1 nF 10 Hz 至 1 kHz 110 nF 至 330 nF CMC 0,25 % + 0,3 nF 10 Hz 至 600 Hz 0,33 µF 至 1,1 µF CMC 0,25 % + 1 nF 10 Hz 至 300 kHz 1,1 µF 至 3,3 µF CMC 0,25 % + 3 nF 10 Hz 至 150 Hz 3,3 µF 至 11 µF CMC 0,25 % + 10 nF 10 Hz 至 120 Hz 11 µF 至 33 µF CMC 0,40 % + 30 nF 10 Hz 至 80 Hz 33 µF 至 110 µF CMC 0,45 % + 100 nF 0 Hz 至 50 Hz 110 µF 至 330 µF CMC 0,45 % + 300 nF 0 Hz 至 20 Hz 0,33 mF 至 1,1 mF CMC 0,45 % + 1 µF 0 Hz 至 6 Hz 1,1 mF 至 3,3 mF CMC 0,45 % + 3 µF 0 Hz 至 2 Hz 3,3 mF 至 11 mF CMC 0,45 % + 10 µF 0 Hz 至 0,6 Hz 11 mF 至 33 mF CMC 0,75 % + 30 µF 0 Hz 至 0,2 Hz 33 mF 至 110 mF CMC 1 % + 100 µF TP7, TP21, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5ae2bfa26cf97583611af651","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"8","test_object":"Współczynnik strat D / Mierniki współczynnika strat","test_object_en":"Loss factor D / Loss factor meters","test_object_zh":"损耗因数 D / 损耗因数测量仪器","test_object_cs":"Ztrátový činitel D / Měřidla ztrátového činitele","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 pF, 100 pF, 1 nF","range":"od -0,001 do 0,001","cmc":"0,00001 (abs.)"},{"name":"10 nF","range":"od -0,001 do 0,001","cmc":"0,000011 (abs.)"},{"name":"100 nF","range":"od -0,001 do 0,001","cmc":"0,00006 (abs.)"},{"name":"10 pF, 100 pF, 1 nF","range":"od 0,001 do 0,01","cmc":"0,00002 (abs.)"},{"name":"100 nF","range":"od 0,001 do 0,01","cmc":"0,00006 (abs.)"},{"name":"1 µF","range":"od 0,001 do 0,01","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 10 nF","range":"od 0,01 do 0,1","cmc":"0,00006 (abs.)"},{"name":"1 nF","range":"od 0,01 do 0,1","cmc":"0,0011 (abs.)"},{"name":"1 µF","range":"od 0,01 do 0,1","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 1 nF, 10 nF","range":"od 0,1 do 1","cmc":"0,0006 (abs.)"},{"name":"100 nF","range":"od 0,1 do 1","cmc":"0,0003 (abs.)"}],"parameters_en":[{"name":"10 pF, 100 pF, 1 nF","range":"-0,001 to 0,001","cmc":"0,00001 (abs.)"},{"name":"10 nF","range":"-0,001 to 0,001","cmc":"0,000011 (abs.)"},{"name":"100 nF","range":"-0,001 to 0,001","cmc":"0,00006 (abs.)"},{"name":"10 pF, 100 pF, 1 nF","range":"0,001 to 0,01","cmc":"0,00002 (abs.)"},{"name":"100 nF","range":"0,001 to 0,01","cmc":"0,00006 (abs.)"},{"name":"1 µF","range":"0,001 to 0,01","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 10 nF","range":"0,01 to 0,1","cmc":"0,00006 (abs.)"},{"name":"1 nF","range":"0,01 to 0,1","cmc":"0,0011 (abs.)"},{"name":"1 µF","range":"0,01 to 0,1","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 1 nF, 10 nF","range":"0,1 to 1","cmc":"0,0006 (abs.)"},{"name":"100 nF","range":"0,1 to 1","cmc":"0,0003 (abs.)"}],"parameters_zh":[{"name":"10 pF, 100 pF, 1 nF","range":"-0,001 至 0,001","cmc":"0,00001 (abs.)"},{"name":"10 nF","range":"-0,001 至 0,001","cmc":"0,000011 (abs.)"},{"name":"100 nF","range":"-0,001 至 0,001","cmc":"0,00006 (abs.)"},{"name":"10 pF, 100 pF, 1 nF","range":"0,001 至 0,01","cmc":"0,00002 (abs.)"},{"name":"100 nF","range":"0,001 至 0,01","cmc":"0,00006 (abs.)"},{"name":"1 µF","range":"0,001 至 0,01","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 10 nF","range":"0,01 至 0,1","cmc":"0,00006 (abs.)"},{"name":"1 nF","range":"0,01 至 0,1","cmc":"0,0011 (abs.)"},{"name":"1 µF","range":"0,01 至 0,1","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 1 nF, 10 nF","range":"0,1 至 1","cmc":"0,0006 (abs.)"},{"name":"100 nF","range":"0,1 至 1","cmc":"0,0003 (abs.)"}],"parameters_cs":[{"name":"10 pF, 100 pF, 1 nF","range":"-0,001 až 0,001","cmc":"0,00001 (abs.)"},{"name":"10 nF","range":"-0,001 až 0,001","cmc":"0,000011 (abs.)"},{"name":"100 nF","range":"-0,001 až 0,001","cmc":"0,00006 (abs.)"},{"name":"10 pF, 100 pF, 1 nF","range":"0,001 až 0,01","cmc":"0,00002 (abs.)"},{"name":"100 nF","range":"0,001 až 0,01","cmc":"0,00006 (abs.)"},{"name":"1 µF","range":"0,001 až 0,01","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 10 nF","range":"0,01 až 0,1","cmc":"0,00006 (abs.)"},{"name":"1 nF","range":"0,01 až 0,1","cmc":"0,0011 (abs.)"},{"name":"1 µF","range":"0,01 až 0,1","cmc":"0,0003 (abs.)"},{"name":"10 pF, 100 pF, 1 nF, 10 nF","range":"0,1 až 1","cmc":"0,0006 (abs.)"},{"name":"100 nF","range":"0,1 až 1","cmc":"0,0003 (abs.)"}],"technique":"Pomiar bezpośredni wzorcowego współczynnika strat przy f = 1 kHz","technique_en":"Direct measurement of reference loss factor at f = 1 kHz","technique_zh":"在 f = 1 kHz 下直接测量标准损耗因数","technique_cs":"Přímé měření etalonového ztrátového činitele při f = 1 kHz","techniques":["Pomiar bezpośredni wzorcowego współczynnika strat przy f = 1 kHz"],"techniques_en":["Direct measurement of reference loss factor at f = 1 kHz"],"techniques_zh":["在 f = 1 kHz 下直接测量标准损耗因数"],"techniques_cs":["Přímé měření etalonového ztrátového činitele při f = 1 kHz"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 pF, 100 pF, 1 nF od -0,001 do 0,001 CMC 0,00001 (abs.)\n10 nF od -0,001 do 0,001 CMC 0,000011 (abs.)\n100 nF od -0,001 do 0,001 CMC 0,00006 (abs.)\n10 pF, 100 pF, 1 nF od 0,001 do 0,01 CMC 0,00002 (abs.)\n100 nF od 0,001 do 0,01 CMC 0,00006 (abs.)\n1 µF od 0,001 do 0,01 CMC 0,0003 (abs.)\n10 pF, 100 pF, 10 nF od 0,01 do 0,1 CMC 0,00006 (abs.)\n1 nF od 0,01 do 0,1 CMC 0,0011 (abs.)\n1 µF od 0,01 do 0,1 CMC 0,0003 (abs.)\n10 pF, 100 pF, 1 nF, 10 nF od 0,1 do 1 CMC 0,0006 (abs.)\n100 nF od 0,1 do 1 CMC 0,0003 (abs.)\nPomiar bezpośredni wzorcowego współczynnika strat przy f = 1 kHz","reference":"TP30, TP24","norm_bases":["TP30","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik strat D / Mierniki współczynnika strat Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorcowego współczynnika strat przy f = 1 kHz 10 pF, 100 pF, 1 nF od -0,001 do 0,001 CMC 0,00001 (abs.) 10 nF od -0,001 do 0,001 CMC 0,000011 (abs.) 100 nF od -0,001 do 0,001 CMC 0,00006 (abs.) 10 pF, 100 pF, 1 nF od 0,001 do 0,01 CMC 0,00002 (abs.) 100 nF od 0,001 do 0,01 CMC 0,00006 (abs.) 1 µF od 0,001 do 0,01 CMC 0,0003 (abs.) 10 pF, 100 pF, 10 nF od 0,01 do 0,1 CMC 0,00006 (abs.) 1 nF od 0,01 do 0,1 CMC 0,0011 (abs.) 1 µF od 0,01 do 0,1 CMC 0,0003 (abs.) 10 pF, 100 pF, 1 nF, 10 nF od 0,1 do 1 CMC 0,0006 (abs.) 100 nF od 0,1 do 1 CMC 0,0003 (abs.) Ztrátový činitel D / Měřidla ztrátového činitele Kalibrace – elektrické veličiny Přímé měření etalonového ztrátového činitele při f = 1 kHz 10 pF, 100 pF, 1 nF -0,001 až 0,001 CMC 0,00001 (abs.) 10 nF -0,001 až 0,001 CMC 0,000011 (abs.) 100 nF -0,001 až 0,001 CMC 0,00006 (abs.) 10 pF, 100 pF, 1 nF 0,001 až 0,01 CMC 0,00002 (abs.) 100 nF 0,001 až 0,01 CMC 0,00006 (abs.) 1 µF 0,001 až 0,01 CMC 0,0003 (abs.) 10 pF, 100 pF, 10 nF 0,01 až 0,1 CMC 0,00006 (abs.) 1 nF 0,01 až 0,1 CMC 0,0011 (abs.) 1 µF 0,01 až 0,1 CMC 0,0003 (abs.) 10 pF, 100 pF, 1 nF, 10 nF 0,1 až 1 CMC 0,0006 (abs.) 100 nF 0,1 až 1 CMC 0,0003 (abs.) TP30, TP24 Wspolczynnik strat D / Mierniki wspolczynnika strat Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorcowego wspolczynnika strat przy f = 1 kHz 10 pF, 100 pF, 1 nF od -0,001 do 0,001 CMC 0,00001 (abs.) 10 nF od -0,001 do 0,001 CMC 0,000011 (abs.) 100 nF od -0,001 do 0,001 CMC 0,00006 (abs.) 10 pF, 100 pF, 1 nF od 0,001 do 0,01 CMC 0,00002 (abs.) 100 nF od 0,001 do 0,01 CMC 0,00006 (abs.) 1 µF od 0,001 do 0,01 CMC 0,0003 (abs.) 10 pF, 100 pF, 10 nF od 0,01 do 0,1 CMC 0,00006 (abs.) 1 nF od 0,01 do 0,1 CMC 0,0011 (abs.) 1 µF od 0,01 do 0,1 CMC 0,0003 (abs.) 10 pF, 100 pF, 1 nF, 10 nF od 0,1 do 1 CMC 0,0006 (abs.) 100 nF od 0,1 do 1 CMC 0,0003 (abs.) Ztratovy cinitel D / Meridla ztratoveho cinitele Kalibrace – elektricke veliciny Prime mereni etalonoveho ztratoveho cinitele pri f = 1 kHz 10 pF, 100 pF, 1 nF -0,001 az 0,001 CMC 0,00001 (abs.) 10 nF -0,001 az 0,001 CMC 0,000011 (abs.) 100 nF -0,001 az 0,001 CMC 0,00006 (abs.) 10 pF, 100 pF, 1 nF 0,001 az 0,01 CMC 0,00002 (abs.) 100 nF 0,001 az 0,01 CMC 0,00006 (abs.) 1 µF 0,001 az 0,01 CMC 0,0003 (abs.) 10 pF, 100 pF, 10 nF 0,01 az 0,1 CMC 0,00006 (abs.) 1 nF 0,01 az 0,1 CMC 0,0011 (abs.) 1 µF 0,01 az 0,1 CMC 0,0003 (abs.) 10 pF, 100 pF, 1 nF, 10 nF 0,1 az 1 CMC 0,0006 (abs.) 100 nF 0,1 az 1 CMC 0,0003 (abs.) TP30, TP24","search_en":"Loss factor D / Loss factor meters Calibration – electrical quantities Direct measurement of reference loss factor at f = 1 kHz 10 pF, 100 pF, 1 nF -0,001 to 0,001 CMC 0,00001 (abs.) 10 nF -0,001 to 0,001 CMC 0,000011 (abs.) 100 nF -0,001 to 0,001 CMC 0,00006 (abs.) 10 pF, 100 pF, 1 nF 0,001 to 0,01 CMC 0,00002 (abs.) 100 nF 0,001 to 0,01 CMC 0,00006 (abs.) 1 µF 0,001 to 0,01 CMC 0,0003 (abs.) 10 pF, 100 pF, 10 nF 0,01 to 0,1 CMC 0,00006 (abs.) 1 nF 0,01 to 0,1 CMC 0,0011 (abs.) 1 µF 0,01 to 0,1 CMC 0,0003 (abs.) 10 pF, 100 pF, 1 nF, 10 nF 0,1 to 1 CMC 0,0006 (abs.) 100 nF 0,1 to 1 CMC 0,0003 (abs.) TP30, TP24","search_zh":"损耗因数 D / 损耗因数测量仪器 校准 – 电学量 在 f = 1 kHz 下直接测量标准损耗因数 10 pF, 100 pF, 1 nF -0,001 至 0,001 CMC 0,00001 (abs.) 10 nF -0,001 至 0,001 CMC 0,000011 (abs.) 100 nF -0,001 至 0,001 CMC 0,00006 (abs.) 10 pF, 100 pF, 1 nF 0,001 至 0,01 CMC 0,00002 (abs.) 100 nF 0,001 至 0,01 CMC 0,00006 (abs.) 1 µF 0,001 至 0,01 CMC 0,0003 (abs.) 10 pF, 100 pF, 10 nF 0,01 至 0,1 CMC 0,00006 (abs.) 1 nF 0,01 至 0,1 CMC 0,0011 (abs.) 1 µF 0,01 至 0,1 CMC 0,0003 (abs.) 10 pF, 100 pF, 1 nF, 10 nF 0,1 至 1 CMC 0,0006 (abs.) 100 nF 0,1 至 1 CMC 0,0003 (abs.) TP30, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a33101c9288a7f6bfb445fe8","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"9","test_object":"Indukcyjność / Wzorce indukcyjności","test_object_en":"Inductance / Inductance standards","test_object_zh":"电感 / 电感标准器","test_object_cs":"Indukčnost / Etalony indukčnosti","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 kHz do 15 kHz","range":"od 1 µH do 5 µH","cmc":"2,4 %"},{"name":"15 kHz do 20 kHz","range":"od 1 µH do 5 µH","cmc":"1,7 %"},{"name":"20 kHz do 25 kHz","range":"od 1 µH do 5 µH","cmc":"1,3 %"},{"name":"25 kHz do 30 kHz","range":"od 1 µH do 5 µH","cmc":"1,1 %"},{"name":"30 kHz do 40 kHz","range":"od 1 µH do 5 µH","cmc":"0,89 %"},{"name":"40 kHz do 50 kHz","range":"od 1 µH do 5 µH","cmc":"0,71 %"},{"name":"50 kHz do 60 kHz","range":"od 1 µH do 5 µH","cmc":"0,60 %"},{"name":"60 kHz do 70 kHz","range":"od 1 µH do 5 µH","cmc":"0,53 %"},{"name":"70 kHz do 80 kHz","range":"od 1 µH do 5 µH","cmc":"0,47 %"},{"name":"80 kHz do 90 kHz","range":"od 1 µH do 5 µH","cmc":"0,43 %"},{"name":"90 kHz do 100 kHz","range":"od 1 µH do 5 µH","cmc":"0,40 %"},{"name":"100 kHz do 150 kHz","range":"od 1 µH do 5 µH","cmc":"0,56 %"},{"name":"150 kHz do 200 kHz","range":"od 1 µH do 5 µH","cmc":"0,45 %"},{"name":"200 kHz do 250 kHz","range":"od 1 µH do 5 µH","cmc":"0,36 %"},{"name":"250 kHz do 300 kHz","range":"od 1 µH do 5 µH","cmc":"0,32 %"},{"name":"300 kHz do 400 kHz","range":"od 1 µH do 5 µH","cmc":"0,36 %"},{"name":"400 kHz do 500 kHz","range":"od 1 µH do 5 µH","cmc":"0,31 %"},{"name":"500 kHz do 700 kHz","range":"od 1 µH do 5 µH","cmc":"0,28 %"},{"name":"700 kHz do 1 MHz","range":"od 1 µH do 5 µH","cmc":"0,24 %"},{"name":"2 kHz do 3 kHz","range":"od 5 µH do 10 µH","cmc":"2,4 %"},{"name":"3 kHz do 5 kHz","range":"od 5 µH do 10 µH","cmc":"1,7 %"},{"name":"5 kHz do 7 kHz","range":"od 5 µH do 10 µH","cmc":"1,1 %"},{"name":"7 kHz do 10 kHz","range":"od 5 µH do 10 µH","cmc":"0,79 %"},{"name":"10 kHz do 15 kHz","range":"od 5 µH do 10 µH","cmc":"0,60 %"},{"name":"15 kHz do 20 kHz","range":"od 5 µH do 10 µH","cmc":"0,45 %"},{"name":"20 kHz do 25 kHz","range":"od 5 µH do 10 µH","cmc":"0,38 %"},{"name":"25 kHz do 30 kHz","range":"od 5 µH do 10 µH","cmc":"0,34 %"},{"name":"30 kHz do 40 kHz","range":"od 5 µH do 10 µH","cmc":"0,31 %"},{"name":"40 kHz do 50 kHz","range":"od 5 µH do 10 µH","cmc":"0,27 %"},{"name":"50 kHz do 60 kHz","range":"od 5 µH do 10 µH","cmc":"0,25 %"},{"name":"60 kHz do 100 kHz","range":"od 5 µH do 10 µH","cmc":"0,23 %"},{"name":"100 kHz do 150 kHz","range":"od 5 µH do 10 µH","cmc":"0,24 %"},{"name":"150 kHz do 200 kHz","range":"od 5 µH do 10 µH","cmc":"0,22 %"},{"name":"200 kHz do 500 kHz","range":"od 5 µH do 10 µH","cmc":"0,20 %"},{"name":"500 kHz do 1 MHz","range":"od 5 µH do 10 µH","cmc":"0,13 %"},{"name":"1 kHz do 2 kHz","range":"od 10 µH do 50 µH","cmc":"2,4 %"},{"name":"2 kHz do 3 kHz","range":"od 10 µH do 50 µH","cmc":"1,3 %"},{"name":"3 kHz do 5 kHz","range":"od 10 µH do 50 µH","cmc":"0,89 %"},{"name":"5 kHz do 7 kHz","range":"od 10 µH do 50 µH","cmc":"0,60 %"},{"name":"7 kHz do 10 kHz","range":"od 10 µH do 50 µH","cmc":"0,47 %"},{"name":"10 kHz do 15 kHz","range":"od 10 µH do 50 µH","cmc":"0,38 %"},{"name":"15 kHz do 20 kHz","range":"od 10 µH do 50 µH","cmc":"0,31 %"},{"name":"20 kHz do 25 kHz","range":"od 10 µH do 50 µH","cmc":"0,27 %"},{"name":"25 kHz do 30 kHz","range":"od 10 µH do 50 µH","cmc":"0,25 %"},{"name":"30 kHz do 50 kHz","range":"od 10 µH do 50 µH","cmc":"0,23 %"},{"name":"50 kHz do 70 kHz","range":"od 10 µH do 50 µH","cmc":"0,21 %"},{"name":"70 kHz do 100 kHz","range":"od 10 µH do 50 µH","cmc":"0,19 %"},{"name":"100 kHz do 250 kHz","range":"od 10 µH do 50 µH","cmc":"0,20 %"},{"name":"250 kHz do 300 kHz","range":"od 10 µH do 50 µH","cmc":"0,12 %"},{"name":"300 kHz do 1 MHz","range":"od 10 µH do 50 µH","cmc":"0,13 %"},{"name":"200 Hz do 300 Hz","range":"od 50 µH do 100 µH","cmc":"2,6 %"},{"name":"300 Hz do 400 Hz","range":"od 50 µH do 100 µH","cmc":"1,8 %"},{"name":"400 Hz do 500 Hz","range":"od 50 µH do 100 µH","cmc":"1,3 %"},{"name":"500 Hz do 600 Hz","range":"od 50 µH do 100 µH","cmc":"1,1 %"},{"name":"600 Hz do 700 Hz","range":"od 50 µH do 100 µH","cmc":"0,89 %"},{"name":"700 Hz do 800 Hz","range":"od 50 µH do 100 µH","cmc":"0,79 %"},{"name":"800 Hz do 900 Hz","range":"od 50 µH do 100 µH","cmc":"0,71 %"},{"name":"900 Hz do 1 kHz","range":"od 50 µH do 100 µH","cmc":"0,65 %"},{"name":"1 kHz do 2 kHz","range":"od 50 µH do 100 µH","cmc":"0,60 %"},{"name":"2 kHz do 3 kHz","range":"od 50 µH do 100 µH","cmc":"0,38 %"},{"name":"3 kHz do 5 kHz","range":"od 50 µH do 100 µH","cmc":"0,31 %"},{"name":"5 kHz do 10 kHz","range":"od 50 µH do 100 µH","cmc":"0,25 %"},{"name":"10 kHz do 15 kHz","range":"od 50 µH do 100 µH","cmc":"0,21 %"},{"name":"15 kHz do 30 kHz","range":"od 50 µH do 100 µH","cmc":"0,19 %"},{"name":"30 kHz do 50 kHz","range":"od 50 µH do 100 µH","cmc":"0,18 %"},{"name":"50 kHz do 100 kHz","range":"od 50 µH do 100 µH","cmc":"0,12 %"},{"name":"100 kHz do 250 kHz","range":"od 50 µH do 100 µH","cmc":"0,20 %"},{"name":"250 kHz do 300 kHz","range":"od 50 µH do 100 µH","cmc":"0,12 %"},{"name":"300 kHz do 1 MHz","range":"od 50 µH do 100 µH","cmc":"0,13 %"},{"name":"80 Hz do 90 Hz","range":"od 100 µH do 500 µH","cmc":"6,2 %"},{"name":"90 Hz do 100 Hz","range":"od 100 µH do 500 µH","cmc":"5,4 %"},{"name":"100 Hz do 200 Hz","range":"od 100 µH do 500 µH","cmc":"2,6 %"},{"name":"200 Hz do 300 Hz","range":"od 100 µH do 500 µH","cmc":"1,3 %"},{"name":"300 Hz do 400 Hz","range":"od 100 µH do 500 µH","cmc":"0,89 %"},{"name":"400 Hz do 500 Hz","range":"od 100 µH do 500 µH","cmc":"0,71 %"},{"name":"500 Hz do 600 Hz","range":"od 100 µH do 500 µH","cmc":"0,60 %"},{"name":"600 Hz do 700 Hz","range":"od 100 µH do 500 µH","cmc":"0,53 %"},{"name":"700 Hz do 800 Hz","range":"od 100 µH do 500 µH","cmc":"0,47 %"},{"name":"800 Hz do 900 Hz","range":"od 100 µH do 500 µH","cmc":"0,43 %"},{"name":"900 Hz do 1 kHz","range":"od 100 µH do 500 µH","cmc":"0,40 %"},{"name":"1 kHz do 2 kHz","range":"od 100 µH do 500 µH","cmc":"0,38 %"},{"name":"2 kHz do 3 kHz","range":"od 100 µH do 500 µH","cmc":"0,27 %"},{"name":"3 kHz do 5 kHz","range":"od 100 µH do 500 µH","cmc":"0,23 %"},{"name":"5 kHz do 10 kHz","range":"od 100 µH do 500 µH","cmc":"0,21 %"},{"name":"10 kHz do 25 kHz","range":"od 100 µH do 500 µH","cmc":"0,18 %"},{"name":"25 kHz do 30 kHz","range":"od 100 µH do 500 µH","cmc":"0,12 %"},{"name":"30 kHz do 100 kHz","range":"od 100 µH do 500 µH","cmc":"0,12 %"},{"name":"100 kHz do 300 kHz","range":"od 100 µH do 500 µH","cmc":"0,11 %"},{"name":"300 kHz do 1 MHz","range":"od 100 µH do 500 µH","cmc":"0,17 %"},{"name":"50 Hz do 60 Hz","range":"od 500 µH do 1 mH","cmc":"2,3 %"},{"name":"60 Hz do 70 Hz","range":"od 500 µH do 1 mH","cmc":"1,9 %"},{"name":"70 Hz do 80 Hz","range":"od 500 µH do 1 mH","cmc":"1,6 %"},{"name":"80 Hz do 100 Hz","range":"od 500 µH do 1 mH","cmc":"1,4 %"},{"name":"100 Hz do 200 Hz","range":"od 500 µH do 1 mH","cmc":"0,60 %"},{"name":"200 Hz do 300 Hz","range":"od 500 µH do 1 mH","cmc":"0,38 %"},{"name":"300 Hz do 400 Hz","range":"od 500 µH do 1 mH","cmc":"0,31 %"},{"name":"400 Hz do 500 Hz","range":"od 500 µH do 1 mH","cmc":"0,27 %"},{"name":"500 Hz do 600 Hz","range":"od 500 µH do 1 mH","cmc":"0,25 %"},{"name":"600 Hz do 900 Hz","range":"od 500 µH do 1 mH","cmc":"0,23 %"},{"name":"900 Hz do 1 kHz","range":"od 500 µH do 1 mH","cmc":"0,21 %"},{"name":"1 kHz do 2 kHz","range":"od 500 µH do 1 mH","cmc":"0,38 %"},{"name":"2 kHz do 3 kHz","range":"od 500 µH do 1 mH","cmc":"0,27 %"},{"name":"3 kHz do 5 kHz","range":"od 500 µH do 1 mH","cmc":"0,23 %"},{"name":"5 kHz do 10 kHz","range":"od 500 µH do 1 mH","cmc":"0,21 %"},{"name":"10 kHz do 25 kHz","range":"od 500 µH do 1 mH","cmc":"0,18 %"},{"name":"25 kHz do 100 kHz","range":"od 500 µH do 1 mH","cmc":"0,12 %"},{"name":"100 kHz do 300 kHz","range":"od 500 µH do 1 mH","cmc":"0,11 %"},{"name":"300 kHz do 1 MHz","range":"od 500 µH do 1 mH","cmc":"0,17 %"},{"name":"20 Hz do 30 Hz","range":"od 1 mH do 5 mH","cmc":"3,9 %"},{"name":"30 Hz do 40 Hz","range":"od 1 mH do 5 mH","cmc":"2,5 %"},{"name":"40 Hz do 50 Hz","range":"od 1 mH do 5 mH","cmc":"1,8 %"},{"name":"50 Hz do 60 Hz","range":"od 1 mH do 5 mH","cmc":"1,3 %"},{"name":"60 Hz do 80 Hz","range":"od 1 mH do 5 mH","cmc":"1,0 %"},{"name":"80 Hz do 90 Hz","range":"od 1 mH do 5 mH","cmc":"0,74 %"},{"name":"90 Hz do 100 Hz","range":"od 1 mH do 5 mH","cmc":"0,66 %"},{"name":"100 Hz do 200 Hz","range":"od 1 mH do 5 mH","cmc":"0,38 %"},{"name":"200 Hz do 300 Hz","range":"od 1 mH do 5 mH","cmc":"0,27 %"},{"name":"300 Hz do 500 Hz","range":"od 1 mH do 5 mH","cmc":"0,23 %"},{"name":"500 Hz do 700 Hz","range":"od 1 mH do 5 mH","cmc":"0,21 %"},{"name":"700 Hz do 1 kHz","range":"od 1 mH do 5 mH","cmc":"0,19 %"},{"name":"1 kHz do 3 kHz","range":"od 1 mH do 5 mH","cmc":"0,18 %"},{"name":"3 kHz do 100 kHz","range":"od 1 mH do 5 mH","cmc":"0,12 %"},{"name":"100 kHz do 300 kHz","range":"od 1 mH do 5 mH","cmc":"0,17 %"},{"name":"300 kHz do 600 kHz","range":"od 1 mH do 5 mH","cmc":"0,21 %"},{"name":"600 kHz do 1 MHz","range":"od 1 mH do 5 mH","cmc":"0,24 %"},{"name":"20 Hz do 30 Hz","range":"od 5 mH do 10 mH","cmc":"1,1 %"},{"name":"30 Hz do 40 Hz","range":"od 5 mH do 10 mH","cmc":"0,75 %"},{"name":"40 Hz do 50 Hz","range":"od 5 mH do 10 mH","cmc":"0,61 %"},{"name":"50 Hz do 60 Hz","range":"od 5 mH do 10 mH","cmc":"0,37 %"},{"name":"60 Hz do 70 Hz","range":"od 5 mH do 10 mH","cmc":"0,33 %"},{"name":"70 Hz do 80 Hz","range":"od 5 mH do 10 mH","cmc":"0,30 %"},{"name":"80 Hz do 90 Hz","range":"od 5 mH do 10 mH","cmc":"0,28 %"},{"name":"90 Hz do 100 Hz","range":"od 5 mH do 10 mH","cmc":"0,26 %"},{"name":"100 Hz do 200 Hz","range":"od 5 mH do 10 mH","cmc":"0,38 %"},{"name":"200 Hz do 300 Hz","range":"od 5 mH do 10 mH","cmc":"0,27 %"},{"name":"300 Hz do 500 Hz","range":"od 5 mH do 10 mH","cmc":"0,23 %"},{"name":"500 Hz do 700 Hz","range":"od 5 mH do 10 mH","cmc":"0,21 %"},{"name":"700 Hz do 1 kHz","range":"od 5 mH do 10 mH","cmc":"0,19 %"},{"name":"1 kHz do 3 kHz","range":"od 5 mH do 10 mH","cmc":"0,18 %"},{"name":"3 kHz do 100 kHz","range":"od 5 mH do 10 mH","cmc":"0,12 %"},{"name":"100 kHz do 300 kHz","range":"od 5 mH do 10 mH","cmc":"0,17 %"},{"name":"300 kHz do 600 kHz","range":"od 5 mH do 10 mH","cmc":"0,21 %"},{"name":"600 kHz do 1 MHz","range":"od 5 mH do 10 mH","cmc":"0,24 %"},{"name":"20 Hz do 30 Hz","range":"od 10 mH do 50 mH","cmc":"0,69 %"},{"name":"30 Hz do 40 Hz","range":"od 10 mH do 50 mH","cmc":"0,54 %"},{"name":"40 Hz do 50 Hz","range":"od 10 mH do 50 mH","cmc":"0,47 %"},{"name":"50 Hz do 60 Hz","range":"od 10 mH do 50 mH","cmc":"0,27 %"},{"name":"60 Hz do 80 Hz","range":"od 10 mH do 50 mH","cmc":"0,24 %"},{"name":"80 Hz do 100 Hz","range":"od 10 mH do 50 mH","cmc":"0,22 %"},{"name":"100 Hz do 250 Hz","range":"od 10 mH do 50 mH","cmc":"0,18 %"},{"name":"250 Hz do 1 kHz","range":"od 10 mH do 50 mH","cmc":"0,12 %"},{"name":"1 kHz do 30 kHz","range":"od 10 mH do 50 mH","cmc":"0,11 %"},{"name":"30 kHz do 100 kHz","range":"od 10 mH do 50 mH","cmc":"0,17 %"},{"name":"100 kHz do 200 kHz","range":"od 10 mH do 50 mH","cmc":"0,21 %"},{"name":"200 kHz do 300 kHz","range":"od 10 mH do 50 mH","cmc":"0,23 %"},{"name":"300 kHz do 400 kHz","range":"od 10 mH do 50 mH","cmc":"0,31 %"},{"name":"400 kHz do 500 kHz","range":"od 10 mH do 50 mH","cmc":"0,35 %"},{"name":"500 kHz do 700 kHz","range":"od 10 mH do 50 mH","cmc":"0,43 %"},{"name":"700 kHz do 1 MHz","range":"od 10 mH do 50 mH","cmc":"0,55 %"},{"name":"20 Hz do 30 Hz","range":"od 50 mH do 100 mH","cmc":"0,40 %"},{"name":"30 Hz do 50 Hz","range":"od 50 mH do 100 mH","cmc":"0,37 %"},{"name":"50 Hz do 60 Hz","range":"od 50 mH do 100 mH","cmc":"0,27 %"},{"name":"60 Hz do 80 Hz","range":"od 50 mH do 100 mH","cmc":"0,24 %"},{"name":"80 Hz do 100 Hz","range":"od 50 mH do 100 mH","cmc":"0,22 %"},{"name":"100 Hz do 250 Hz","range":"od 50 mH do 100 mH","cmc":"0,18 %"},{"name":"250 Hz do 1 kHz","range":"od 50 mH do 100 mH","cmc":"0,12 %"},{"name":"1 kHz do 30 kHz","range":"od 50 mH do 100 mH","cmc":"0,11 %"},{"name":"30 kHz do 100 kHz","range":"od 50 mH do 100 mH","cmc":"0,17 %"},{"name":"100 kHz do 200 kHz","range":"od 50 mH do 100 mH","cmc":"0,21 %"},{"name":"200 kHz do 300 kHz","range":"od 50 mH do 100 mH","cmc":"0,23 %"},{"name":"300 kHz do 400 kHz","range":"od 50 mH do 100 mH","cmc":"0,47 %"},{"name":"400 kHz do 500 kHz","range":"od 50 mH do 100 mH","cmc":"0,55 %"},{"name":"500 kHz do 600 kHz","range":"od 50 mH do 100 mH","cmc":"0,62 %"},{"name":"600 kHz do 700 kHz","range":"od 50 mH do 100 mH","cmc":"0,70 %"},{"name":"700 kHz do 800 kHz","range":"od 50 mH do 100 mH","cmc":"0,78 %"},{"name":"800 kHz do 1 MHz","range":"od 50 mH do 100 mH","cmc":"0,93 %"},{"name":"20 Hz do 30 Hz","range":"od 100 mH do 500 mH","cmc":"0,27 %"},{"name":"30 Hz do 50 Hz","range":"od 100 mH do 500 mH","cmc":"0,35 %"},{"name":"50 Hz do 100 Hz","range":"od 100 mH do 500 mH","cmc":"0,18 %"},{"name":"100 Hz do 1 kHz","range":"od 100 mH do 500 mH","cmc":"0,12 %"},{"name":"1 kHz do 30 kHz","range":"od 100 mH do 500 mH","cmc":"0,13 %"},{"name":"30 kHz do 60 kHz","range":"od 100 mH do 500 mH","cmc":"0,21 %"},{"name":"60 kHz do 100 kHz","range":"od 100 mH do 500 mH","cmc":"0,24 %"},{"name":"100 kHz do 150 kHz","range":"od 100 mH do 500 mH","cmc":"0,33 %"},{"name":"150 kHz do 200 kHz","range":"od 100 mH do 500 mH","cmc":"0,39 %"},{"name":"200 kHz do 250 kHz","range":"od 100 mH do 500 mH","cmc":"0,45 %"},{"name":"250 kHz do 300 kHz","range":"od 100 mH do 500 mH","cmc":"0,51 %"},{"name":"300 kHz do 400 kHz","range":"od 100 mH do 500 mH","cmc":"1,8 %"},{"name":"400 kHz do 500 kHz","range":"od 100 mH do 500 mH","cmc":"2,1 %"},{"name":"500 kHz do 600 kHz","range":"od 100 mH do 500 mH","cmc":"2,5 %"},{"name":"600 kHz do 700 kHz","range":"od 100 mH do 500 mH","cmc":"2,9 %"},{"name":"700 kHz do 800 kHz","range":"od 100 mH do 500 mH","cmc":"3,3 %"},{"name":"800 kHz do 900 kHz","range":"od 100 mH do 500 mH","cmc":"3,7 %"},{"name":"900 kHz do 1 MHz","range":"od 100 mH do 500 mH","cmc":"4,1 %"},{"name":"20 Hz do 30 Hz","range":"od 500 mH do 1 H","cmc":"0,27 %"},{"name":"30 Hz do 50 Hz","range":"od 500 mH do 1 H","cmc":"0,35 %"},{"name":"50 Hz do 100 Hz","range":"od 500 mH do 1 H","cmc":"0,18 %"},{"name":"100 Hz do 1 kHz","range":"od 500 mH do 1 H","cmc":"0,12 %"},{"name":"1 kHz do 30 kHz","range":"od 500 mH do 1 H","cmc":"0,13 %"},{"name":"30 kHz do 60 kHz","range":"od 500 mH do 1 H","cmc":"0,21 %"},{"name":"60 kHz do 100 kHz","range":"od 500 mH do 1 H","cmc":"0,24 %"},{"name":"100 kHz do 150 kHz","range":"od 500 mH do 1 H","cmc":"0,51 %"},{"name":"150 kHz do 200 kHz","range":"od 500 mH do 1 H","cmc":"0,62 %"},{"name":"200 kHz do 250 kHz","range":"od 500 mH do 1 H","cmc":"0,74 %"},{"name":"250 kHz do 300 kHz","range":"od 500 mH do 1 H","cmc":"0,86 %"},{"name":"300 kHz do 400 kHz","range":"od 500 mH do 1 H","cmc":"3,3 %"},{"name":"400 kHz do 500 kHz","range":"od 500 mH do 1 H","cmc":"4,1 %"},{"name":"500 kHz do 600 kHz","range":"od 500 mH do 1 H","cmc":"4,9 %"},{"name":"600 kHz do 700 kHz","range":"od 500 mH do 1 H","cmc":"5,6 %"},{"name":"700 kHz do 800 kHz","range":"od 500 mH do 1 H","cmc":"6,4 %"},{"name":"800 kHz do 900 kHz","range":"od 500 mH do 1 H","cmc":"7,2 %"},{"name":"900 kHz do 1 MHz","range":"od 500 mH do 1 H","cmc":"8,0 %"},{"name":"20 Hz do 50 Hz","range":"od 1 H do 2 H","cmc":"0,34 %"},{"name":"50 Hz do 100 Hz","range":"od 1 H do 2 H","cmc":"0,18 %"},{"name":"100 Hz do 1 kHz","range":"od 1 H do 2 H","cmc":"0,12 %"},{"name":"1 kHz do 5 kHz","range":"od 1 H do 2 H","cmc":"0,15 %"},{"name":"5 kHz do 10 kHz","range":"od 1 H do 2 H","cmc":"0,24 %"},{"name":"10 kHz do 15 kHz","range":"od 1 H do 2 H","cmc":"0,28 %"},{"name":"15 kHz do 20 kHz","range":"od 1 H do 2 H","cmc":"0,31 %"},{"name":"20 kHz do 25 kHz","range":"od 1 H do 2 H","cmc":"0,35 %"},{"name":"25 kHz do 30 kHz","range":"od 1 H do 2 H","cmc":"0,38 %"},{"name":"30 kHz do 50 kHz","range":"od 1 H do 2 H","cmc":"0,35 %"},{"name":"50 kHz do 70 kHz","range":"od 1 H do 2 H","cmc":"0,43 %"},{"name":"70 kHz do 100 kHz","range":"od 1 H do 2 H","cmc":"0,55 %"},{"name":"100 kHz do 150 kHz","range":"od 1 H do 2 H","cmc":"1,9 %"},{"name":"150 kHz do 200 kHz","range":"od 1 H do 2 H","cmc":"2,5 %"},{"name":"200 kHz do 250 kHz","range":"od 1 H do 2 H","cmc":"3,1 %"},{"name":"250 kHz do 300 kHz","range":"od 1 H do 2 H","cmc":"3,7 %"},{"name":"300 kHz do 400 kHz","range":"od 1 H do 2 H","cmc":"6,4 %"},{"name":"400 kHz do 500 kHz","range":"od 1 H do 2 H","cmc":"8,0 %"},{"name":"20 Hz do 50 Hz","range":"od 2 H do 5 H","cmc":"0,34 %"},{"name":"50 Hz do 100 Hz","range":"od 2 H do 5 H","cmc":"0,18 %"},{"name":"100 Hz do 1 kHz","range":"od 2 H do 5 H","cmc":"0,12 %"},{"name":"1 kHz do 5 kHz","range":"od 2 H do 5 H","cmc":"0,15 %"},{"name":"5 kHz do 10 kHz","range":"od 2 H do 5 H","cmc":"0,24 %"},{"name":"10 kHz do 15 kHz","range":"od 2 H do 5 H","cmc":"0,28 %"},{"name":"15 kHz do 20 kHz","range":"od 2 H do 5 H","cmc":"0,31 %"},{"name":"20 kHz do 25 kHz","range":"od 2 H do 5 H","cmc":"0,35 %"},{"name":"25 kHz do 30 kHz","range":"od 2 H do 5 H","cmc":"0,38 %"},{"name":"30 kHz do 50 kHz","range":"od 2 H do 5 H","cmc":"0,35 %"},{"name":"50 kHz do 70 kHz","range":"od 2 H do 5 H","cmc":"0,43 %"},{"name":"70 kHz do 100 kHz","range":"od 2 H do 5 H","cmc":"0,55 %"},{"name":"100 kHz do 150 kHz","range":"od 2 H do 5 H","cmc":"1,9 %"},{"name":"150 kHz do 200 kHz","range":"od 2 H do 5 H","cmc":"2,5 %"},{"name":"200 kHz do 250 kHz","range":"od 2 H do 5 H","cmc":"3,1 %"},{"name":"250 kHz do 300 kHz","range":"od 2 H do 5 H","cmc":"3,7 %"},{"name":"50 Hz do 100 Hz","range":"od 5 H do 10 H","cmc":"0,18 %"},{"name":"100 Hz do 1 kHz","range":"od 5 H do 10 H","cmc":"0,12 %"},{"name":"1 kHz do 5 kHz","range":"od 5 H do 10 H","cmc":"0,15 %"},{"name":"5 kHz do 10 kHz","range":"od 5 H do 10 H","cmc":"0,24 %"},{"name":"10 kHz do 15 kHz","range":"od 5 H do 10 H","cmc":"0,28 %"},{"name":"15 kHz do 20 kHz","range":"od 5 H do 10 H","cmc":"0,31 %"},{"name":"20 kHz do 25 kHz","range":"od 5 H do 10 H","cmc":"0,35 %"},{"name":"25 kHz do 30 kHz","range":"od 5 H do 10 H","cmc":"0,38 %"},{"name":"30 kHz do 40 kHz","range":"od 5 H do 10 H","cmc":"0,47 %"},{"name":"40 kHz do 50 kHz","range":"od 5 H do 10 H","cmc":"0,55 %"},{"name":"50 kHz do 60 kHz","range":"od 5 H do 10 H","cmc":"0,62 %"},{"name":"60 kHz do 70 kHz","range":"od 5 H do 10 H","cmc":"0,70 %"},{"name":"70 kHz do 80 kHz","range":"od 5 H do 10 H","cmc":"0,78 %"},{"name":"80 kHz do 90 kHz","range":"od 5 H do 10 H","cmc":"0,86 %"},{"name":"90 kHz do 100 kHz","range":"od 5 H do 10 H","cmc":"0,93 %"},{"name":"100 kHz do 150 kHz","range":"od 5 H do 10 H","cmc":"3,7 %"},{"name":"150 kHz do 200 kHz","range":"od 5 H do 10 H","cmc":"4,9 %"},{"name":"200 kHz do 250 kHz","range":"od 5 H do 10 H","cmc":"6,0 %"},{"name":"250 kHz do 300 kHz","range":"od 5 H do 10 H","cmc":"7,2 %"},{"name":"50 Hz do 100 Hz","range":"od 10 H do 50 H","cmc":"0,18 %"},{"name":"100 Hz do 500 Hz","range":"od 10 H do 50 H","cmc":"0,15 %"},{"name":"500 Hz do 800 Hz","range":"od 10 H do 50 H","cmc":"0,22 %"},{"name":"800 Hz do 2 kHz","range":"od 10 H do 50 H","cmc":"0,24 %"},{"name":"2 kHz do 3 kHz","range":"od 10 H do 50 H","cmc":"0,28 %"},{"name":"3 kHz do 5 kHz","range":"od 10 H do 50 H","cmc":"0,35 %"},{"name":"5 kHz do 7 kHz","range":"od 10 H do 50 H","cmc":"0,43 %"},{"name":"7 kHz do 10 kHz","range":"od 10 H do 50 H","cmc":"0,55 %"},{"name":"10 kHz do 15 kHz","range":"od 10 H do 50 H","cmc":"0,74 %"},{"name":"15 kHz do 20 kHz","range":"od 10 H do 50 H","cmc":"0,93 %"},{"name":"20 kHz do 25 kHz","range":"od 10 H do 50 H","cmc":"1,2 %"},{"name":"25 kHz do 30 kHz","range":"od 10 H do 50 H","cmc":"1,4 %"},{"name":"30 kHz do 40 kHz","range":"od 10 H do 50 H","cmc":"1,8 %"},{"name":"40 kHz do 50 kHz","range":"od 10 H do 50 H","cmc":"2,1 %"},{"name":"50 kHz do 60 kHz","range":"od 10 H do 50 H","cmc":"2,5 %"},{"name":"60 kHz do 70 kHz","range":"od 10 H do 50 H","cmc":"2,9 %"},{"name":"70 kHz do 80 kHz","range":"od 10 H do 50 H","cmc":"3,3 %"},{"name":"80 kHz do 90 kHz","range":"od 10 H do 50 H","cmc":"3,7 %"},{"name":"90 kHz do 100 kHz","range":"od 10 H do 50 H","cmc":"4,1 %"},{"name":"50 Hz do 100 Hz","range":"od 50 H do 100 H","cmc":"0,18 %"},{"name":"100 Hz do 500 Hz","range":"od 50 H do 100 H","cmc":"0,15 %"},{"name":"500 Hz do 800 Hz","range":"od 50 H do 100 H","cmc":"0,22 %"},{"name":"800 Hz do 1 kHz","range":"od 50 H do 100 H","cmc":"0,24 %"},{"name":"1 kHz do 2 kHz","range":"od 50 H do 100 H","cmc":"0,31 %"},{"name":"2 kHz do 3 kHz","range":"od 50 H do 100 H","cmc":"0,39 %"},{"name":"3 kHz do 5 kHz","range":"od 50 H do 100 H","cmc":"0,55 %"},{"name":"5 kHz do 7 kHz","range":"od 50 H do 100 H","cmc":"0,70 %"},{"name":"7 kHz do 10 kHz","range":"od 50 H do 100 H","cmc":"0,93 %"},{"name":"10 kHz do 15 kHz","range":"od 50 H do 100 H","cmc":"1,4 %"},{"name":"15 kHz do 20 kHz","range":"od 50 H do 100 H","cmc":"1,8 %"},{"name":"20 kHz do 25 kHz","range":"od 50 H do 100 H","cmc":"2,1 %"},{"name":"25 kHz do 30 kHz","range":"od 50 H do 100 H","cmc":"2,5 %"},{"name":"20 Hz do 35 Hz","range":"od 100 H do 500 H","cmc":"0,38 %"},{"name":"35 Hz do 50 Hz","range":"od 100 H do 500 H","cmc":"0,40 %"},{"name":"50 Hz do 70 Hz","range":"od 100 H do 500 H","cmc":"0,28 %"},{"name":"70 Hz do 200 Hz","range":"od 100 H do 500 H","cmc":"0,31 %"},{"name":"200 Hz do 300 Hz","range":"od 100 H do 500 H","cmc":"0,39 %"},{"name":"300 Hz do 400 Hz","range":"od 100 H do 500 H","cmc":"0,47 %"},{"name":"400 Hz do 500 Hz","range":"od 100 H do 500 H","cmc":"0,55 %"},{"name":"500 Hz do 600 Hz","range":"od 100 H do 500 H","cmc":"0,62 %"},{"name":"600 Hz do 700 Hz","range":"od 100 H do 500 H","cmc":"0,70 %"},{"name":"700 Hz do 800 Hz","range":"od 100 H do 500 H","cmc":"0,78 %"},{"name":"800 Hz do 900 Hz","range":"od 100 H do 500 H","cmc":"0,86 %"},{"name":"900 Hz do 2 kHz","range":"od 100 H do 500 H","cmc":"0,93 %"},{"name":"2 kHz do 3 kHz","range":"od 100 H do 500 H","cmc":"1,4 %"},{"name":"3 kHz do 5 kHz","range":"od 100 H do 500 H","cmc":"2,1 %"},{"name":"5 kHz do 7 kHz","range":"od 100 H do 500 H","cmc":"2,9 %"},{"name":"7 kHz do 8 kHz","range":"od 100 H do 500 H","cmc":"3,3 %"},{"name":"8 kHz do 9 kHz","range":"od 100 H do 500 H","cmc":"3,7 %"},{"name":"9 kHz do 10 kHz","range":"od 100 H do 500 H","cmc":"4,1 %"},{"name":"20 Hz do 35 Hz","range":"od 500 H do 1 kH","cmc":"0,38 %"},{"name":"35 Hz do 50 Hz","range":"od 500 H do 1 kH","cmc":"0,40 %"},{"name":"50 Hz do 70 Hz","range":"od 500 H do 1 kH","cmc":"0,28 %"},{"name":"70 Hz do 100 Hz","range":"od 500 H do 1 kH","cmc":"0,31 %"},{"name":"100 Hz do 200 Hz","range":"od 500 H do 1 kH","cmc":"0,31 %"},{"name":"200 Hz do 300 Hz","range":"od 500 H do 1 kH","cmc":"0,39 %"},{"name":"300 Hz do 400 Hz","range":"od 500 H do 1 kH","cmc":"0,47 %"},{"name":"400 Hz do 500 Hz","range":"od 500 H do 1 kH","cmc":"0,55 %"},{"name":"500 Hz do 600 Hz","range":"od 500 H do 1 kH","cmc":"0,62 %"},{"name":"600 Hz do 700 Hz","range":"od 500 H do 1 kH","cmc":"0,70 %"},{"name":"700 Hz do 800 Hz","range":"od 500 H do 1 kH","cmc":"0,78 %"},{"name":"800 Hz do 900 Hz","range":"od 500 H do 1 kH","cmc":"0,86 %"},{"name":"900 Hz do 1 kHz","range":"od 500 H do 1 kH","cmc":"0,93 %"}],"parameters_en":[{"name":"10 kHz to 15 kHz","range":"1 µH to 5 µH","cmc":"2,4 %"},{"name":"15 kHz to 20 kHz","range":"1 µH to 5 µH","cmc":"1,7 %"},{"name":"20 kHz to 25 kHz","range":"1 µH to 5 µH","cmc":"1,3 %"},{"name":"25 kHz to 30 kHz","range":"1 µH to 5 µH","cmc":"1,1 %"},{"name":"30 kHz to 40 kHz","range":"1 µH to 5 µH","cmc":"0,89 %"},{"name":"40 kHz to 50 kHz","range":"1 µH to 5 µH","cmc":"0,71 %"},{"name":"50 kHz to 60 kHz","range":"1 µH to 5 µH","cmc":"0,60 %"},{"name":"60 kHz to 70 kHz","range":"1 µH to 5 µH","cmc":"0,53 %"},{"name":"70 kHz to 80 kHz","range":"1 µH to 5 µH","cmc":"0,47 %"},{"name":"80 kHz to 90 kHz","range":"1 µH to 5 µH","cmc":"0,43 %"},{"name":"90 kHz to 100 kHz","range":"1 µH to 5 µH","cmc":"0,40 %"},{"name":"100 kHz to 150 kHz","range":"1 µH to 5 µH","cmc":"0,56 %"},{"name":"150 kHz to 200 kHz","range":"1 µH to 5 µH","cmc":"0,45 %"},{"name":"200 kHz to 250 kHz","range":"1 µH to 5 µH","cmc":"0,36 %"},{"name":"250 kHz to 300 kHz","range":"1 µH to 5 µH","cmc":"0,32 %"},{"name":"300 kHz to 400 kHz","range":"1 µH to 5 µH","cmc":"0,36 %"},{"name":"400 kHz to 500 kHz","range":"1 µH to 5 µH","cmc":"0,31 %"},{"name":"500 kHz to 700 kHz","range":"1 µH to 5 µH","cmc":"0,28 %"},{"name":"700 kHz to 1 MHz","range":"1 µH to 5 µH","cmc":"0,24 %"},{"name":"2 kHz to 3 kHz","range":"5 µH to 10 µH","cmc":"2,4 %"},{"name":"3 kHz to 5 kHz","range":"5 µH to 10 µH","cmc":"1,7 %"},{"name":"5 kHz to 7 kHz","range":"5 µH to 10 µH","cmc":"1,1 %"},{"name":"7 kHz to 10 kHz","range":"5 µH to 10 µH","cmc":"0,79 %"},{"name":"10 kHz to 15 kHz","range":"5 µH to 10 µH","cmc":"0,60 %"},{"name":"15 kHz to 20 kHz","range":"5 µH to 10 µH","cmc":"0,45 %"},{"name":"20 kHz to 25 kHz","range":"5 µH to 10 µH","cmc":"0,38 %"},{"name":"25 kHz to 30 kHz","range":"5 µH to 10 µH","cmc":"0,34 %"},{"name":"30 kHz to 40 kHz","range":"5 µH to 10 µH","cmc":"0,31 %"},{"name":"40 kHz to 50 kHz","range":"5 µH to 10 µH","cmc":"0,27 %"},{"name":"50 kHz to 60 kHz","range":"5 µH to 10 µH","cmc":"0,25 %"},{"name":"60 kHz to 100 kHz","range":"5 µH to 10 µH","cmc":"0,23 %"},{"name":"100 kHz to 150 kHz","range":"5 µH to 10 µH","cmc":"0,24 %"},{"name":"150 kHz to 200 kHz","range":"5 µH to 10 µH","cmc":"0,22 %"},{"name":"200 kHz to 500 kHz","range":"5 µH to 10 µH","cmc":"0,20 %"},{"name":"500 kHz to 1 MHz","range":"5 µH to 10 µH","cmc":"0,13 %"},{"name":"1 kHz to 2 kHz","range":"10 µH to 50 µH","cmc":"2,4 %"},{"name":"2 kHz to 3 kHz","range":"10 µH to 50 µH","cmc":"1,3 %"},{"name":"3 kHz to 5 kHz","range":"10 µH to 50 µH","cmc":"0,89 %"},{"name":"5 kHz to 7 kHz","range":"10 µH to 50 µH","cmc":"0,60 %"},{"name":"7 kHz to 10 kHz","range":"10 µH to 50 µH","cmc":"0,47 %"},{"name":"10 kHz to 15 kHz","range":"10 µH to 50 µH","cmc":"0,38 %"},{"name":"15 kHz to 20 kHz","range":"10 µH to 50 µH","cmc":"0,31 %"},{"name":"20 kHz to 25 kHz","range":"10 µH to 50 µH","cmc":"0,27 %"},{"name":"25 kHz to 30 kHz","range":"10 µH to 50 µH","cmc":"0,25 %"},{"name":"30 kHz to 50 kHz","range":"10 µH to 50 µH","cmc":"0,23 %"},{"name":"50 kHz to 70 kHz","range":"10 µH to 50 µH","cmc":"0,21 %"},{"name":"70 kHz to 100 kHz","range":"10 µH to 50 µH","cmc":"0,19 %"},{"name":"100 kHz to 250 kHz","range":"10 µH to 50 µH","cmc":"0,20 %"},{"name":"250 kHz to 300 kHz","range":"10 µH to 50 µH","cmc":"0,12 %"},{"name":"300 kHz to 1 MHz","range":"10 µH to 50 µH","cmc":"0,13 %"},{"name":"200 Hz to 300 Hz","range":"50 µH to 100 µH","cmc":"2,6 %"},{"name":"300 Hz to 400 Hz","range":"50 µH to 100 µH","cmc":"1,8 %"},{"name":"400 Hz to 500 Hz","range":"50 µH to 100 µH","cmc":"1,3 %"},{"name":"500 Hz to 600 Hz","range":"50 µH to 100 µH","cmc":"1,1 %"},{"name":"600 Hz to 700 Hz","range":"50 µH to 100 µH","cmc":"0,89 %"},{"name":"700 Hz to 800 Hz","range":"50 µH to 100 µH","cmc":"0,79 %"},{"name":"800 Hz to 900 Hz","range":"50 µH to 100 µH","cmc":"0,71 %"},{"name":"900 Hz to 1 kHz","range":"50 µH to 100 µH","cmc":"0,65 %"},{"name":"1 kHz to 2 kHz","range":"50 µH to 100 µH","cmc":"0,60 %"},{"name":"2 kHz to 3 kHz","range":"50 µH to 100 µH","cmc":"0,38 %"},{"name":"3 kHz to 5 kHz","range":"50 µH to 100 µH","cmc":"0,31 %"},{"name":"5 kHz to 10 kHz","range":"50 µH to 100 µH","cmc":"0,25 %"},{"name":"10 kHz to 15 kHz","range":"50 µH to 100 µH","cmc":"0,21 %"},{"name":"15 kHz to 30 kHz","range":"50 µH to 100 µH","cmc":"0,19 %"},{"name":"30 kHz to 50 kHz","range":"50 µH to 100 µH","cmc":"0,18 %"},{"name":"50 kHz to 100 kHz","range":"50 µH to 100 µH","cmc":"0,12 %"},{"name":"100 kHz to 250 kHz","range":"50 µH to 100 µH","cmc":"0,20 %"},{"name":"250 kHz to 300 kHz","range":"50 µH to 100 µH","cmc":"0,12 %"},{"name":"300 kHz to 1 MHz","range":"50 µH to 100 µH","cmc":"0,13 %"},{"name":"80 Hz to 90 Hz","range":"100 µH to 500 µH","cmc":"6,2 %"},{"name":"90 Hz to 100 Hz","range":"100 µH to 500 µH","cmc":"5,4 %"},{"name":"100 Hz to 200 Hz","range":"100 µH to 500 µH","cmc":"2,6 %"},{"name":"200 Hz to 300 Hz","range":"100 µH to 500 µH","cmc":"1,3 %"},{"name":"300 Hz to 400 Hz","range":"100 µH to 500 µH","cmc":"0,89 %"},{"name":"400 Hz to 500 Hz","range":"100 µH to 500 µH","cmc":"0,71 %"},{"name":"500 Hz to 600 Hz","range":"100 µH to 500 µH","cmc":"0,60 %"},{"name":"600 Hz to 700 Hz","range":"100 µH to 500 µH","cmc":"0,53 %"},{"name":"700 Hz to 800 Hz","range":"100 µH to 500 µH","cmc":"0,47 %"},{"name":"800 Hz to 900 Hz","range":"100 µH to 500 µH","cmc":"0,43 %"},{"name":"900 Hz to 1 kHz","range":"100 µH to 500 µH","cmc":"0,40 %"},{"name":"1 kHz to 2 kHz","range":"100 µH to 500 µH","cmc":"0,38 %"},{"name":"2 kHz to 3 kHz","range":"100 µH to 500 µH","cmc":"0,27 %"},{"name":"3 kHz to 5 kHz","range":"100 µH to 500 µH","cmc":"0,23 %"},{"name":"5 kHz to 10 kHz","range":"100 µH to 500 µH","cmc":"0,21 %"},{"name":"10 kHz to 25 kHz","range":"100 µH to 500 µH","cmc":"0,18 %"},{"name":"25 kHz to 30 kHz","range":"100 µH to 500 µH","cmc":"0,12 %"},{"name":"30 kHz to 100 kHz","range":"100 µH to 500 µH","cmc":"0,12 %"},{"name":"100 kHz to 300 kHz","range":"100 µH to 500 µH","cmc":"0,11 %"},{"name":"300 kHz to 1 MHz","range":"100 µH to 500 µH","cmc":"0,17 %"},{"name":"50 Hz to 60 Hz","range":"500 µH to 1 mH","cmc":"2,3 %"},{"name":"60 Hz to 70 Hz","range":"500 µH to 1 mH","cmc":"1,9 %"},{"name":"70 Hz to 80 Hz","range":"500 µH to 1 mH","cmc":"1,6 %"},{"name":"80 Hz to 100 Hz","range":"500 µH to 1 mH","cmc":"1,4 %"},{"name":"100 Hz to 200 Hz","range":"500 µH to 1 mH","cmc":"0,60 %"},{"name":"200 Hz to 300 Hz","range":"500 µH to 1 mH","cmc":"0,38 %"},{"name":"300 Hz to 400 Hz","range":"500 µH to 1 mH","cmc":"0,31 %"},{"name":"400 Hz to 500 Hz","range":"500 µH to 1 mH","cmc":"0,27 %"},{"name":"500 Hz to 600 Hz","range":"500 µH to 1 mH","cmc":"0,25 %"},{"name":"600 Hz to 900 Hz","range":"500 µH to 1 mH","cmc":"0,23 %"},{"name":"900 Hz to 1 kHz","range":"500 µH to 1 mH","cmc":"0,21 %"},{"name":"1 kHz to 2 kHz","range":"500 µH to 1 mH","cmc":"0,38 %"},{"name":"2 kHz to 3 kHz","range":"500 µH to 1 mH","cmc":"0,27 %"},{"name":"3 kHz to 5 kHz","range":"500 µH to 1 mH","cmc":"0,23 %"},{"name":"5 kHz to 10 kHz","range":"500 µH to 1 mH","cmc":"0,21 %"},{"name":"10 kHz to 25 kHz","range":"500 µH to 1 mH","cmc":"0,18 %"},{"name":"25 kHz to 100 kHz","range":"500 µH to 1 mH","cmc":"0,12 %"},{"name":"100 kHz to 300 kHz","range":"500 µH to 1 mH","cmc":"0,11 %"},{"name":"300 kHz to 1 MHz","range":"500 µH to 1 mH","cmc":"0,17 %"},{"name":"20 Hz to 30 Hz","range":"1 mH to 5 mH","cmc":"3,9 %"},{"name":"30 Hz to 40 Hz","range":"1 mH to 5 mH","cmc":"2,5 %"},{"name":"40 Hz to 50 Hz","range":"1 mH to 5 mH","cmc":"1,8 %"},{"name":"50 Hz to 60 Hz","range":"1 mH to 5 mH","cmc":"1,3 %"},{"name":"60 Hz to 80 Hz","range":"1 mH to 5 mH","cmc":"1,0 %"},{"name":"80 Hz to 90 Hz","range":"1 mH to 5 mH","cmc":"0,74 %"},{"name":"90 Hz to 100 Hz","range":"1 mH to 5 mH","cmc":"0,66 %"},{"name":"100 Hz to 200 Hz","range":"1 mH to 5 mH","cmc":"0,38 %"},{"name":"200 Hz to 300 Hz","range":"1 mH to 5 mH","cmc":"0,27 %"},{"name":"300 Hz to 500 Hz","range":"1 mH to 5 mH","cmc":"0,23 %"},{"name":"500 Hz to 700 Hz","range":"1 mH to 5 mH","cmc":"0,21 %"},{"name":"700 Hz to 1 kHz","range":"1 mH to 5 mH","cmc":"0,19 %"},{"name":"1 kHz to 3 kHz","range":"1 mH to 5 mH","cmc":"0,18 %"},{"name":"3 kHz to 100 kHz","range":"1 mH to 5 mH","cmc":"0,12 %"},{"name":"100 kHz to 300 kHz","range":"1 mH to 5 mH","cmc":"0,17 %"},{"name":"300 kHz to 600 kHz","range":"1 mH to 5 mH","cmc":"0,21 %"},{"name":"600 kHz to 1 MHz","range":"1 mH to 5 mH","cmc":"0,24 %"},{"name":"20 Hz to 30 Hz","range":"5 mH to 10 mH","cmc":"1,1 %"},{"name":"30 Hz to 40 Hz","range":"5 mH to 10 mH","cmc":"0,75 %"},{"name":"40 Hz to 50 Hz","range":"5 mH to 10 mH","cmc":"0,61 %"},{"name":"50 Hz to 60 Hz","range":"5 mH to 10 mH","cmc":"0,37 %"},{"name":"60 Hz to 70 Hz","range":"5 mH to 10 mH","cmc":"0,33 %"},{"name":"70 Hz to 80 Hz","range":"5 mH to 10 mH","cmc":"0,30 %"},{"name":"80 Hz to 90 Hz","range":"5 mH to 10 mH","cmc":"0,28 %"},{"name":"90 Hz to 100 Hz","range":"5 mH to 10 mH","cmc":"0,26 %"},{"name":"100 Hz to 200 Hz","range":"5 mH to 10 mH","cmc":"0,38 %"},{"name":"200 Hz to 300 Hz","range":"5 mH to 10 mH","cmc":"0,27 %"},{"name":"300 Hz to 500 Hz","range":"5 mH to 10 mH","cmc":"0,23 %"},{"name":"500 Hz to 700 Hz","range":"5 mH to 10 mH","cmc":"0,21 %"},{"name":"700 Hz to 1 kHz","range":"5 mH to 10 mH","cmc":"0,19 %"},{"name":"1 kHz to 3 kHz","range":"5 mH to 10 mH","cmc":"0,18 %"},{"name":"3 kHz to 100 kHz","range":"5 mH to 10 mH","cmc":"0,12 %"},{"name":"100 kHz to 300 kHz","range":"5 mH to 10 mH","cmc":"0,17 %"},{"name":"300 kHz to 600 kHz","range":"5 mH to 10 mH","cmc":"0,21 %"},{"name":"600 kHz to 1 MHz","range":"5 mH to 10 mH","cmc":"0,24 %"},{"name":"20 Hz to 30 Hz","range":"10 mH to 50 mH","cmc":"0,69 %"},{"name":"30 Hz to 40 Hz","range":"10 mH to 50 mH","cmc":"0,54 %"},{"name":"40 Hz to 50 Hz","range":"10 mH to 50 mH","cmc":"0,47 %"},{"name":"50 Hz to 60 Hz","range":"10 mH to 50 mH","cmc":"0,27 %"},{"name":"60 Hz to 80 Hz","range":"10 mH to 50 mH","cmc":"0,24 %"},{"name":"80 Hz to 100 Hz","range":"10 mH to 50 mH","cmc":"0,22 %"},{"name":"100 Hz to 250 Hz","range":"10 mH to 50 mH","cmc":"0,18 %"},{"name":"250 Hz to 1 kHz","range":"10 mH to 50 mH","cmc":"0,12 %"},{"name":"1 kHz to 30 kHz","range":"10 mH to 50 mH","cmc":"0,11 %"},{"name":"30 kHz to 100 kHz","range":"10 mH to 50 mH","cmc":"0,17 %"},{"name":"100 kHz to 200 kHz","range":"10 mH to 50 mH","cmc":"0,21 %"},{"name":"200 kHz to 300 kHz","range":"10 mH to 50 mH","cmc":"0,23 %"},{"name":"300 kHz to 400 kHz","range":"10 mH to 50 mH","cmc":"0,31 %"},{"name":"400 kHz to 500 kHz","range":"10 mH to 50 mH","cmc":"0,35 %"},{"name":"500 kHz to 700 kHz","range":"10 mH to 50 mH","cmc":"0,43 %"},{"name":"700 kHz to 1 MHz","range":"10 mH to 50 mH","cmc":"0,55 %"},{"name":"20 Hz to 30 Hz","range":"50 mH to 100 mH","cmc":"0,40 %"},{"name":"30 Hz to 50 Hz","range":"50 mH to 100 mH","cmc":"0,37 %"},{"name":"50 Hz to 60 Hz","range":"50 mH to 100 mH","cmc":"0,27 %"},{"name":"60 Hz to 80 Hz","range":"50 mH to 100 mH","cmc":"0,24 %"},{"name":"80 Hz to 100 Hz","range":"50 mH to 100 mH","cmc":"0,22 %"},{"name":"100 Hz to 250 Hz","range":"50 mH to 100 mH","cmc":"0,18 %"},{"name":"250 Hz to 1 kHz","range":"50 mH to 100 mH","cmc":"0,12 %"},{"name":"1 kHz to 30 kHz","range":"50 mH to 100 mH","cmc":"0,11 %"},{"name":"30 kHz to 100 kHz","range":"50 mH to 100 mH","cmc":"0,17 %"},{"name":"100 kHz to 200 kHz","range":"50 mH to 100 mH","cmc":"0,21 %"},{"name":"200 kHz to 300 kHz","range":"50 mH to 100 mH","cmc":"0,23 %"},{"name":"300 kHz to 400 kHz","range":"50 mH to 100 mH","cmc":"0,47 %"},{"name":"400 kHz to 500 kHz","range":"50 mH to 100 mH","cmc":"0,55 %"},{"name":"500 kHz to 600 kHz","range":"50 mH to 100 mH","cmc":"0,62 %"},{"name":"600 kHz to 700 kHz","range":"50 mH to 100 mH","cmc":"0,70 %"},{"name":"700 kHz to 800 kHz","range":"50 mH to 100 mH","cmc":"0,78 %"},{"name":"800 kHz to 1 MHz","range":"50 mH to 100 mH","cmc":"0,93 %"},{"name":"20 Hz to 30 Hz","range":"100 mH to 500 mH","cmc":"0,27 %"},{"name":"30 Hz to 50 Hz","range":"100 mH to 500 mH","cmc":"0,35 %"},{"name":"50 Hz to 100 Hz","range":"100 mH to 500 mH","cmc":"0,18 %"},{"name":"100 Hz to 1 kHz","range":"100 mH to 500 mH","cmc":"0,12 %"},{"name":"1 kHz to 30 kHz","range":"100 mH to 500 mH","cmc":"0,13 %"},{"name":"30 kHz to 60 kHz","range":"100 mH to 500 mH","cmc":"0,21 %"},{"name":"60 kHz to 100 kHz","range":"100 mH to 500 mH","cmc":"0,24 %"},{"name":"100 kHz to 150 kHz","range":"100 mH to 500 mH","cmc":"0,33 %"},{"name":"150 kHz to 200 kHz","range":"100 mH to 500 mH","cmc":"0,39 %"},{"name":"200 kHz to 250 kHz","range":"100 mH to 500 mH","cmc":"0,45 %"},{"name":"250 kHz to 300 kHz","range":"100 mH to 500 mH","cmc":"0,51 %"},{"name":"300 kHz to 400 kHz","range":"100 mH to 500 mH","cmc":"1,8 %"},{"name":"400 kHz to 500 kHz","range":"100 mH to 500 mH","cmc":"2,1 %"},{"name":"500 kHz to 600 kHz","range":"100 mH to 500 mH","cmc":"2,5 %"},{"name":"600 kHz to 700 kHz","range":"100 mH to 500 mH","cmc":"2,9 %"},{"name":"700 kHz to 800 kHz","range":"100 mH to 500 mH","cmc":"3,3 %"},{"name":"800 kHz to 900 kHz","range":"100 mH to 500 mH","cmc":"3,7 %"},{"name":"900 kHz to 1 MHz","range":"100 mH to 500 mH","cmc":"4,1 %"},{"name":"20 Hz to 30 Hz","range":"500 mH to 1 H","cmc":"0,27 %"},{"name":"30 Hz to 50 Hz","range":"500 mH to 1 H","cmc":"0,35 %"},{"name":"50 Hz to 100 Hz","range":"500 mH to 1 H","cmc":"0,18 %"},{"name":"100 Hz to 1 kHz","range":"500 mH to 1 H","cmc":"0,12 %"},{"name":"1 kHz to 30 kHz","range":"500 mH to 1 H","cmc":"0,13 %"},{"name":"30 kHz to 60 kHz","range":"500 mH to 1 H","cmc":"0,21 %"},{"name":"60 kHz to 100 kHz","range":"500 mH to 1 H","cmc":"0,24 %"},{"name":"100 kHz to 150 kHz","range":"500 mH to 1 H","cmc":"0,51 %"},{"name":"150 kHz to 200 kHz","range":"500 mH to 1 H","cmc":"0,62 %"},{"name":"200 kHz to 250 kHz","range":"500 mH to 1 H","cmc":"0,74 %"},{"name":"250 kHz to 300 kHz","range":"500 mH to 1 H","cmc":"0,86 %"},{"name":"300 kHz to 400 kHz","range":"500 mH to 1 H","cmc":"3,3 %"},{"name":"400 kHz to 500 kHz","range":"500 mH to 1 H","cmc":"4,1 %"},{"name":"500 kHz to 600 kHz","range":"500 mH to 1 H","cmc":"4,9 %"},{"name":"600 kHz to 700 kHz","range":"500 mH to 1 H","cmc":"5,6 %"},{"name":"700 kHz to 800 kHz","range":"500 mH to 1 H","cmc":"6,4 %"},{"name":"800 kHz to 900 kHz","range":"500 mH to 1 H","cmc":"7,2 %"},{"name":"900 kHz to 1 MHz","range":"500 mH to 1 H","cmc":"8,0 %"},{"name":"20 Hz to 50 Hz","range":"1 H to 2 H","cmc":"0,34 %"},{"name":"50 Hz to 100 Hz","range":"1 H to 2 H","cmc":"0,18 %"},{"name":"100 Hz to 1 kHz","range":"1 H to 2 H","cmc":"0,12 %"},{"name":"1 kHz to 5 kHz","range":"1 H to 2 H","cmc":"0,15 %"},{"name":"5 kHz to 10 kHz","range":"1 H to 2 H","cmc":"0,24 %"},{"name":"10 kHz to 15 kHz","range":"1 H to 2 H","cmc":"0,28 %"},{"name":"15 kHz to 20 kHz","range":"1 H to 2 H","cmc":"0,31 %"},{"name":"20 kHz to 25 kHz","range":"1 H to 2 H","cmc":"0,35 %"},{"name":"25 kHz to 30 kHz","range":"1 H to 2 H","cmc":"0,38 %"},{"name":"30 kHz to 50 kHz","range":"1 H to 2 H","cmc":"0,35 %"},{"name":"50 kHz to 70 kHz","range":"1 H to 2 H","cmc":"0,43 %"},{"name":"70 kHz to 100 kHz","range":"1 H to 2 H","cmc":"0,55 %"},{"name":"100 kHz to 150 kHz","range":"1 H to 2 H","cmc":"1,9 %"},{"name":"150 kHz to 200 kHz","range":"1 H to 2 H","cmc":"2,5 %"},{"name":"200 kHz to 250 kHz","range":"1 H to 2 H","cmc":"3,1 %"},{"name":"250 kHz to 300 kHz","range":"1 H to 2 H","cmc":"3,7 %"},{"name":"300 kHz to 400 kHz","range":"1 H to 2 H","cmc":"6,4 %"},{"name":"400 kHz to 500 kHz","range":"1 H to 2 H","cmc":"8,0 %"},{"name":"20 Hz to 50 Hz","range":"2 H to 5 H","cmc":"0,34 %"},{"name":"50 Hz to 100 Hz","range":"2 H to 5 H","cmc":"0,18 %"},{"name":"100 Hz to 1 kHz","range":"2 H to 5 H","cmc":"0,12 %"},{"name":"1 kHz to 5 kHz","range":"2 H to 5 H","cmc":"0,15 %"},{"name":"5 kHz to 10 kHz","range":"2 H to 5 H","cmc":"0,24 %"},{"name":"10 kHz to 15 kHz","range":"2 H to 5 H","cmc":"0,28 %"},{"name":"15 kHz to 20 kHz","range":"2 H to 5 H","cmc":"0,31 %"},{"name":"20 kHz to 25 kHz","range":"2 H to 5 H","cmc":"0,35 %"},{"name":"25 kHz to 30 kHz","range":"2 H to 5 H","cmc":"0,38 %"},{"name":"30 kHz to 50 kHz","range":"2 H to 5 H","cmc":"0,35 %"},{"name":"50 kHz to 70 kHz","range":"2 H to 5 H","cmc":"0,43 %"},{"name":"70 kHz to 100 kHz","range":"2 H to 5 H","cmc":"0,55 %"},{"name":"100 kHz to 150 kHz","range":"2 H to 5 H","cmc":"1,9 %"},{"name":"150 kHz to 200 kHz","range":"2 H to 5 H","cmc":"2,5 %"},{"name":"200 kHz to 250 kHz","range":"2 H to 5 H","cmc":"3,1 %"},{"name":"250 kHz to 300 kHz","range":"2 H to 5 H","cmc":"3,7 %"},{"name":"50 Hz to 100 Hz","range":"5 H to 10 H","cmc":"0,18 %"},{"name":"100 Hz to 1 kHz","range":"5 H to 10 H","cmc":"0,12 %"},{"name":"1 kHz to 5 kHz","range":"5 H to 10 H","cmc":"0,15 %"},{"name":"5 kHz to 10 kHz","range":"5 H to 10 H","cmc":"0,24 %"},{"name":"10 kHz to 15 kHz","range":"5 H to 10 H","cmc":"0,28 %"},{"name":"15 kHz to 20 kHz","range":"5 H to 10 H","cmc":"0,31 %"},{"name":"20 kHz to 25 kHz","range":"5 H to 10 H","cmc":"0,35 %"},{"name":"25 kHz to 30 kHz","range":"5 H to 10 H","cmc":"0,38 %"},{"name":"30 kHz to 40 kHz","range":"5 H to 10 H","cmc":"0,47 %"},{"name":"40 kHz to 50 kHz","range":"5 H to 10 H","cmc":"0,55 %"},{"name":"50 kHz to 60 kHz","range":"5 H to 10 H","cmc":"0,62 %"},{"name":"60 kHz to 70 kHz","range":"5 H to 10 H","cmc":"0,70 %"},{"name":"70 kHz to 80 kHz","range":"5 H to 10 H","cmc":"0,78 %"},{"name":"80 kHz to 90 kHz","range":"5 H to 10 H","cmc":"0,86 %"},{"name":"90 kHz to 100 kHz","range":"5 H to 10 H","cmc":"0,93 %"},{"name":"100 kHz to 150 kHz","range":"5 H to 10 H","cmc":"3,7 %"},{"name":"150 kHz to 200 kHz","range":"5 H to 10 H","cmc":"4,9 %"},{"name":"200 kHz to 250 kHz","range":"5 H to 10 H","cmc":"6,0 %"},{"name":"250 kHz to 300 kHz","range":"5 H to 10 H","cmc":"7,2 %"},{"name":"50 Hz to 100 Hz","range":"10 H to 50 H","cmc":"0,18 %"},{"name":"100 Hz to 500 Hz","range":"10 H to 50 H","cmc":"0,15 %"},{"name":"500 Hz to 800 Hz","range":"10 H to 50 H","cmc":"0,22 %"},{"name":"800 Hz to 2 kHz","range":"10 H to 50 H","cmc":"0,24 %"},{"name":"2 kHz to 3 kHz","range":"10 H to 50 H","cmc":"0,28 %"},{"name":"3 kHz to 5 kHz","range":"10 H to 50 H","cmc":"0,35 %"},{"name":"5 kHz to 7 kHz","range":"10 H to 50 H","cmc":"0,43 %"},{"name":"7 kHz to 10 kHz","range":"10 H to 50 H","cmc":"0,55 %"},{"name":"10 kHz to 15 kHz","range":"10 H to 50 H","cmc":"0,74 %"},{"name":"15 kHz to 20 kHz","range":"10 H to 50 H","cmc":"0,93 %"},{"name":"20 kHz to 25 kHz","range":"10 H to 50 H","cmc":"1,2 %"},{"name":"25 kHz to 30 kHz","range":"10 H to 50 H","cmc":"1,4 %"},{"name":"30 kHz to 40 kHz","range":"10 H to 50 H","cmc":"1,8 %"},{"name":"40 kHz to 50 kHz","range":"10 H to 50 H","cmc":"2,1 %"},{"name":"50 kHz to 60 kHz","range":"10 H to 50 H","cmc":"2,5 %"},{"name":"60 kHz to 70 kHz","range":"10 H to 50 H","cmc":"2,9 %"},{"name":"70 kHz to 80 kHz","range":"10 H to 50 H","cmc":"3,3 %"},{"name":"80 kHz to 90 kHz","range":"10 H to 50 H","cmc":"3,7 %"},{"name":"90 kHz to 100 kHz","range":"10 H to 50 H","cmc":"4,1 %"},{"name":"50 Hz to 100 Hz","range":"50 H to 100 H","cmc":"0,18 %"},{"name":"100 Hz to 500 Hz","range":"50 H to 100 H","cmc":"0,15 %"},{"name":"500 Hz to 800 Hz","range":"50 H to 100 H","cmc":"0,22 %"},{"name":"800 Hz to 1 kHz","range":"50 H to 100 H","cmc":"0,24 %"},{"name":"1 kHz to 2 kHz","range":"50 H to 100 H","cmc":"0,31 %"},{"name":"2 kHz to 3 kHz","range":"50 H to 100 H","cmc":"0,39 %"},{"name":"3 kHz to 5 kHz","range":"50 H to 100 H","cmc":"0,55 %"},{"name":"5 kHz to 7 kHz","range":"50 H to 100 H","cmc":"0,70 %"},{"name":"7 kHz to 10 kHz","range":"50 H to 100 H","cmc":"0,93 %"},{"name":"10 kHz to 15 kHz","range":"50 H to 100 H","cmc":"1,4 %"},{"name":"15 kHz to 20 kHz","range":"50 H to 100 H","cmc":"1,8 %"},{"name":"20 kHz to 25 kHz","range":"50 H to 100 H","cmc":"2,1 %"},{"name":"25 kHz to 30 kHz","range":"50 H to 100 H","cmc":"2,5 %"},{"name":"20 Hz to 35 Hz","range":"100 H to 500 H","cmc":"0,38 %"},{"name":"35 Hz to 50 Hz","range":"100 H to 500 H","cmc":"0,40 %"},{"name":"50 Hz to 70 Hz","range":"100 H to 500 H","cmc":"0,28 %"},{"name":"70 Hz to 200 Hz","range":"100 H to 500 H","cmc":"0,31 %"},{"name":"200 Hz to 300 Hz","range":"100 H to 500 H","cmc":"0,39 %"},{"name":"300 Hz to 400 Hz","range":"100 H to 500 H","cmc":"0,47 %"},{"name":"400 Hz to 500 Hz","range":"100 H to 500 H","cmc":"0,55 %"},{"name":"500 Hz to 600 Hz","range":"100 H to 500 H","cmc":"0,62 %"},{"name":"600 Hz to 700 Hz","range":"100 H to 500 H","cmc":"0,70 %"},{"name":"700 Hz to 800 Hz","range":"100 H to 500 H","cmc":"0,78 %"},{"name":"800 Hz to 900 Hz","range":"100 H to 500 H","cmc":"0,86 %"},{"name":"900 Hz to 2 kHz","range":"100 H to 500 H","cmc":"0,93 %"},{"name":"2 kHz to 3 kHz","range":"100 H to 500 H","cmc":"1,4 %"},{"name":"3 kHz to 5 kHz","range":"100 H to 500 H","cmc":"2,1 %"},{"name":"5 kHz to 7 kHz","range":"100 H to 500 H","cmc":"2,9 %"},{"name":"7 kHz to 8 kHz","range":"100 H to 500 H","cmc":"3,3 %"},{"name":"8 kHz to 9 kHz","range":"100 H to 500 H","cmc":"3,7 %"},{"name":"9 kHz to 10 kHz","range":"100 H to 500 H","cmc":"4,1 %"},{"name":"20 Hz to 35 Hz","range":"500 H to 1 kH","cmc":"0,38 %"},{"name":"35 Hz to 50 Hz","range":"500 H to 1 kH","cmc":"0,40 %"},{"name":"50 Hz to 70 Hz","range":"500 H to 1 kH","cmc":"0,28 %"},{"name":"70 Hz to 100 Hz","range":"500 H to 1 kH","cmc":"0,31 %"},{"name":"100 Hz to 200 Hz","range":"500 H to 1 kH","cmc":"0,31 %"},{"name":"200 Hz to 300 Hz","range":"500 H to 1 kH","cmc":"0,39 %"},{"name":"300 Hz to 400 Hz","range":"500 H to 1 kH","cmc":"0,47 %"},{"name":"400 Hz to 500 Hz","range":"500 H to 1 kH","cmc":"0,55 %"},{"name":"500 Hz to 600 Hz","range":"500 H to 1 kH","cmc":"0,62 %"},{"name":"600 Hz to 700 Hz","range":"500 H to 1 kH","cmc":"0,70 %"},{"name":"700 Hz to 800 Hz","range":"500 H to 1 kH","cmc":"0,78 %"},{"name":"800 Hz to 900 Hz","range":"500 H to 1 kH","cmc":"0,86 %"},{"name":"900 Hz to 1 kHz","range":"500 H to 1 kH","cmc":"0,93 %"}],"parameters_zh":[{"name":"10 kHz 至 15 kHz","range":"1 µH 至 5 µH","cmc":"2,4 %"},{"name":"15 kHz 至 20 kHz","range":"1 µH 至 5 µH","cmc":"1,7 %"},{"name":"20 kHz 至 25 kHz","range":"1 µH 至 5 µH","cmc":"1,3 %"},{"name":"25 kHz 至 30 kHz","range":"1 µH 至 5 µH","cmc":"1,1 %"},{"name":"30 kHz 至 40 kHz","range":"1 µH 至 5 µH","cmc":"0,89 %"},{"name":"40 kHz 至 50 kHz","range":"1 µH 至 5 µH","cmc":"0,71 %"},{"name":"50 kHz 至 60 kHz","range":"1 µH 至 5 µH","cmc":"0,60 %"},{"name":"60 kHz 至 70 kHz","range":"1 µH 至 5 µH","cmc":"0,53 %"},{"name":"70 kHz 至 80 kHz","range":"1 µH 至 5 µH","cmc":"0,47 %"},{"name":"80 kHz 至 90 kHz","range":"1 µH 至 5 µH","cmc":"0,43 %"},{"name":"90 kHz 至 100 kHz","range":"1 µH 至 5 µH","cmc":"0,40 %"},{"name":"100 kHz 至 150 kHz","range":"1 µH 至 5 µH","cmc":"0,56 %"},{"name":"150 kHz 至 200 kHz","range":"1 µH 至 5 µH","cmc":"0,45 %"},{"name":"200 kHz 至 250 kHz","range":"1 µH 至 5 µH","cmc":"0,36 %"},{"name":"250 kHz 至 300 kHz","range":"1 µH 至 5 µH","cmc":"0,32 %"},{"name":"300 kHz 至 400 kHz","range":"1 µH 至 5 µH","cmc":"0,36 %"},{"name":"400 kHz 至 500 kHz","range":"1 µH 至 5 µH","cmc":"0,31 %"},{"name":"500 kHz 至 700 kHz","range":"1 µH 至 5 µH","cmc":"0,28 %"},{"name":"700 kHz 至 1 MHz","range":"1 µH 至 5 µH","cmc":"0,24 %"},{"name":"2 kHz 至 3 kHz","range":"5 µH 至 10 µH","cmc":"2,4 %"},{"name":"3 kHz 至 5 kHz","range":"5 µH 至 10 µH","cmc":"1,7 %"},{"name":"5 kHz 至 7 kHz","range":"5 µH 至 10 µH","cmc":"1,1 %"},{"name":"7 kHz 至 10 kHz","range":"5 µH 至 10 µH","cmc":"0,79 %"},{"name":"10 kHz 至 15 kHz","range":"5 µH 至 10 µH","cmc":"0,60 %"},{"name":"15 kHz 至 20 kHz","range":"5 µH 至 10 µH","cmc":"0,45 %"},{"name":"20 kHz 至 25 kHz","range":"5 µH 至 10 µH","cmc":"0,38 %"},{"name":"25 kHz 至 30 kHz","range":"5 µH 至 10 µH","cmc":"0,34 %"},{"name":"30 kHz 至 40 kHz","range":"5 µH 至 10 µH","cmc":"0,31 %"},{"name":"40 kHz 至 50 kHz","range":"5 µH 至 10 µH","cmc":"0,27 %"},{"name":"50 kHz 至 60 kHz","range":"5 µH 至 10 µH","cmc":"0,25 %"},{"name":"60 kHz 至 100 kHz","range":"5 µH 至 10 µH","cmc":"0,23 %"},{"name":"100 kHz 至 150 kHz","range":"5 µH 至 10 µH","cmc":"0,24 %"},{"name":"150 kHz 至 200 kHz","range":"5 µH 至 10 µH","cmc":"0,22 %"},{"name":"200 kHz 至 500 kHz","range":"5 µH 至 10 µH","cmc":"0,20 %"},{"name":"500 kHz 至 1 MHz","range":"5 µH 至 10 µH","cmc":"0,13 %"},{"name":"1 kHz 至 2 kHz","range":"10 µH 至 50 µH","cmc":"2,4 %"},{"name":"2 kHz 至 3 kHz","range":"10 µH 至 50 µH","cmc":"1,3 %"},{"name":"3 kHz 至 5 kHz","range":"10 µH 至 50 µH","cmc":"0,89 %"},{"name":"5 kHz 至 7 kHz","range":"10 µH 至 50 µH","cmc":"0,60 %"},{"name":"7 kHz 至 10 kHz","range":"10 µH 至 50 µH","cmc":"0,47 %"},{"name":"10 kHz 至 15 kHz","range":"10 µH 至 50 µH","cmc":"0,38 %"},{"name":"15 kHz 至 20 kHz","range":"10 µH 至 50 µH","cmc":"0,31 %"},{"name":"20 kHz 至 25 kHz","range":"10 µH 至 50 µH","cmc":"0,27 %"},{"name":"25 kHz 至 30 kHz","range":"10 µH 至 50 µH","cmc":"0,25 %"},{"name":"30 kHz 至 50 kHz","range":"10 µH 至 50 µH","cmc":"0,23 %"},{"name":"50 kHz 至 70 kHz","range":"10 µH 至 50 µH","cmc":"0,21 %"},{"name":"70 kHz 至 100 kHz","range":"10 µH 至 50 µH","cmc":"0,19 %"},{"name":"100 kHz 至 250 kHz","range":"10 µH 至 50 µH","cmc":"0,20 %"},{"name":"250 kHz 至 300 kHz","range":"10 µH 至 50 µH","cmc":"0,12 %"},{"name":"300 kHz 至 1 MHz","range":"10 µH 至 50 µH","cmc":"0,13 %"},{"name":"200 Hz 至 300 Hz","range":"50 µH 至 100 µH","cmc":"2,6 %"},{"name":"300 Hz 至 400 Hz","range":"50 µH 至 100 µH","cmc":"1,8 %"},{"name":"400 Hz 至 500 Hz","range":"50 µH 至 100 µH","cmc":"1,3 %"},{"name":"500 Hz 至 600 Hz","range":"50 µH 至 100 µH","cmc":"1,1 %"},{"name":"600 Hz 至 700 Hz","range":"50 µH 至 100 µH","cmc":"0,89 %"},{"name":"700 Hz 至 800 Hz","range":"50 µH 至 100 µH","cmc":"0,79 %"},{"name":"800 Hz 至 900 Hz","range":"50 µH 至 100 µH","cmc":"0,71 %"},{"name":"900 Hz 至 1 kHz","range":"50 µH 至 100 µH","cmc":"0,65 %"},{"name":"1 kHz 至 2 kHz","range":"50 µH 至 100 µH","cmc":"0,60 %"},{"name":"2 kHz 至 3 kHz","range":"50 µH 至 100 µH","cmc":"0,38 %"},{"name":"3 kHz 至 5 kHz","range":"50 µH 至 100 µH","cmc":"0,31 %"},{"name":"5 kHz 至 10 kHz","range":"50 µH 至 100 µH","cmc":"0,25 %"},{"name":"10 kHz 至 15 kHz","range":"50 µH 至 100 µH","cmc":"0,21 %"},{"name":"15 kHz 至 30 kHz","range":"50 µH 至 100 µH","cmc":"0,19 %"},{"name":"30 kHz 至 50 kHz","range":"50 µH 至 100 µH","cmc":"0,18 %"},{"name":"50 kHz 至 100 kHz","range":"50 µH 至 100 µH","cmc":"0,12 %"},{"name":"100 kHz 至 250 kHz","range":"50 µH 至 100 µH","cmc":"0,20 %"},{"name":"250 kHz 至 300 kHz","range":"50 µH 至 100 µH","cmc":"0,12 %"},{"name":"300 kHz 至 1 MHz","range":"50 µH 至 100 µH","cmc":"0,13 %"},{"name":"80 Hz 至 90 Hz","range":"100 µH 至 500 µH","cmc":"6,2 %"},{"name":"90 Hz 至 100 Hz","range":"100 µH 至 500 µH","cmc":"5,4 %"},{"name":"100 Hz 至 200 Hz","range":"100 µH 至 500 µH","cmc":"2,6 %"},{"name":"200 Hz 至 300 Hz","range":"100 µH 至 500 µH","cmc":"1,3 %"},{"name":"300 Hz 至 400 Hz","range":"100 µH 至 500 µH","cmc":"0,89 %"},{"name":"400 Hz 至 500 Hz","range":"100 µH 至 500 µH","cmc":"0,71 %"},{"name":"500 Hz 至 600 Hz","range":"100 µH 至 500 µH","cmc":"0,60 %"},{"name":"600 Hz 至 700 Hz","range":"100 µH 至 500 µH","cmc":"0,53 %"},{"name":"700 Hz 至 800 Hz","range":"100 µH 至 500 µH","cmc":"0,47 %"},{"name":"800 Hz 至 900 Hz","range":"100 µH 至 500 µH","cmc":"0,43 %"},{"name":"900 Hz 至 1 kHz","range":"100 µH 至 500 µH","cmc":"0,40 %"},{"name":"1 kHz 至 2 kHz","range":"100 µH 至 500 µH","cmc":"0,38 %"},{"name":"2 kHz 至 3 kHz","range":"100 µH 至 500 µH","cmc":"0,27 %"},{"name":"3 kHz 至 5 kHz","range":"100 µH 至 500 µH","cmc":"0,23 %"},{"name":"5 kHz 至 10 kHz","range":"100 µH 至 500 µH","cmc":"0,21 %"},{"name":"10 kHz 至 25 kHz","range":"100 µH 至 500 µH","cmc":"0,18 %"},{"name":"25 kHz 至 30 kHz","range":"100 µH 至 500 µH","cmc":"0,12 %"},{"name":"30 kHz 至 100 kHz","range":"100 µH 至 500 µH","cmc":"0,12 %"},{"name":"100 kHz 至 300 kHz","range":"100 µH 至 500 µH","cmc":"0,11 %"},{"name":"300 kHz 至 1 MHz","range":"100 µH 至 500 µH","cmc":"0,17 %"},{"name":"50 Hz 至 60 Hz","range":"500 µH 至 1 mH","cmc":"2,3 %"},{"name":"60 Hz 至 70 Hz","range":"500 µH 至 1 mH","cmc":"1,9 %"},{"name":"70 Hz 至 80 Hz","range":"500 µH 至 1 mH","cmc":"1,6 %"},{"name":"80 Hz 至 100 Hz","range":"500 µH 至 1 mH","cmc":"1,4 %"},{"name":"100 Hz 至 200 Hz","range":"500 µH 至 1 mH","cmc":"0,60 %"},{"name":"200 Hz 至 300 Hz","range":"500 µH 至 1 mH","cmc":"0,38 %"},{"name":"300 Hz 至 400 Hz","range":"500 µH 至 1 mH","cmc":"0,31 %"},{"name":"400 Hz 至 500 Hz","range":"500 µH 至 1 mH","cmc":"0,27 %"},{"name":"500 Hz 至 600 Hz","range":"500 µH 至 1 mH","cmc":"0,25 %"},{"name":"600 Hz 至 900 Hz","range":"500 µH 至 1 mH","cmc":"0,23 %"},{"name":"900 Hz 至 1 kHz","range":"500 µH 至 1 mH","cmc":"0,21 %"},{"name":"1 kHz 至 2 kHz","range":"500 µH 至 1 mH","cmc":"0,38 %"},{"name":"2 kHz 至 3 kHz","range":"500 µH 至 1 mH","cmc":"0,27 %"},{"name":"3 kHz 至 5 kHz","range":"500 µH 至 1 mH","cmc":"0,23 %"},{"name":"5 kHz 至 10 kHz","range":"500 µH 至 1 mH","cmc":"0,21 %"},{"name":"10 kHz 至 25 kHz","range":"500 µH 至 1 mH","cmc":"0,18 %"},{"name":"25 kHz 至 100 kHz","range":"500 µH 至 1 mH","cmc":"0,12 %"},{"name":"100 kHz 至 300 kHz","range":"500 µH 至 1 mH","cmc":"0,11 %"},{"name":"300 kHz 至 1 MHz","range":"500 µH 至 1 mH","cmc":"0,17 %"},{"name":"20 Hz 至 30 Hz","range":"1 mH 至 5 mH","cmc":"3,9 %"},{"name":"30 Hz 至 40 Hz","range":"1 mH 至 5 mH","cmc":"2,5 %"},{"name":"40 Hz 至 50 Hz","range":"1 mH 至 5 mH","cmc":"1,8 %"},{"name":"50 Hz 至 60 Hz","range":"1 mH 至 5 mH","cmc":"1,3 %"},{"name":"60 Hz 至 80 Hz","range":"1 mH 至 5 mH","cmc":"1,0 %"},{"name":"80 Hz 至 90 Hz","range":"1 mH 至 5 mH","cmc":"0,74 %"},{"name":"90 Hz 至 100 Hz","range":"1 mH 至 5 mH","cmc":"0,66 %"},{"name":"100 Hz 至 200 Hz","range":"1 mH 至 5 mH","cmc":"0,38 %"},{"name":"200 Hz 至 300 Hz","range":"1 mH 至 5 mH","cmc":"0,27 %"},{"name":"300 Hz 至 500 Hz","range":"1 mH 至 5 mH","cmc":"0,23 %"},{"name":"500 Hz 至 700 Hz","range":"1 mH 至 5 mH","cmc":"0,21 %"},{"name":"700 Hz 至 1 kHz","range":"1 mH 至 5 mH","cmc":"0,19 %"},{"name":"1 kHz 至 3 kHz","range":"1 mH 至 5 mH","cmc":"0,18 %"},{"name":"3 kHz 至 100 kHz","range":"1 mH 至 5 mH","cmc":"0,12 %"},{"name":"100 kHz 至 300 kHz","range":"1 mH 至 5 mH","cmc":"0,17 %"},{"name":"300 kHz 至 600 kHz","range":"1 mH 至 5 mH","cmc":"0,21 %"},{"name":"600 kHz 至 1 MHz","range":"1 mH 至 5 mH","cmc":"0,24 %"},{"name":"20 Hz 至 30 Hz","range":"5 mH 至 10 mH","cmc":"1,1 %"},{"name":"30 Hz 至 40 Hz","range":"5 mH 至 10 mH","cmc":"0,75 %"},{"name":"40 Hz 至 50 Hz","range":"5 mH 至 10 mH","cmc":"0,61 %"},{"name":"50 Hz 至 60 Hz","range":"5 mH 至 10 mH","cmc":"0,37 %"},{"name":"60 Hz 至 70 Hz","range":"5 mH 至 10 mH","cmc":"0,33 %"},{"name":"70 Hz 至 80 Hz","range":"5 mH 至 10 mH","cmc":"0,30 %"},{"name":"80 Hz 至 90 Hz","range":"5 mH 至 10 mH","cmc":"0,28 %"},{"name":"90 Hz 至 100 Hz","range":"5 mH 至 10 mH","cmc":"0,26 %"},{"name":"100 Hz 至 200 Hz","range":"5 mH 至 10 mH","cmc":"0,38 %"},{"name":"200 Hz 至 300 Hz","range":"5 mH 至 10 mH","cmc":"0,27 %"},{"name":"300 Hz 至 500 Hz","range":"5 mH 至 10 mH","cmc":"0,23 %"},{"name":"500 Hz 至 700 Hz","range":"5 mH 至 10 mH","cmc":"0,21 %"},{"name":"700 Hz 至 1 kHz","range":"5 mH 至 10 mH","cmc":"0,19 %"},{"name":"1 kHz 至 3 kHz","range":"5 mH 至 10 mH","cmc":"0,18 %"},{"name":"3 kHz 至 100 kHz","range":"5 mH 至 10 mH","cmc":"0,12 %"},{"name":"100 kHz 至 300 kHz","range":"5 mH 至 10 mH","cmc":"0,17 %"},{"name":"300 kHz 至 600 kHz","range":"5 mH 至 10 mH","cmc":"0,21 %"},{"name":"600 kHz 至 1 MHz","range":"5 mH 至 10 mH","cmc":"0,24 %"},{"name":"20 Hz 至 30 Hz","range":"10 mH 至 50 mH","cmc":"0,69 %"},{"name":"30 Hz 至 40 Hz","range":"10 mH 至 50 mH","cmc":"0,54 %"},{"name":"40 Hz 至 50 Hz","range":"10 mH 至 50 mH","cmc":"0,47 %"},{"name":"50 Hz 至 60 Hz","range":"10 mH 至 50 mH","cmc":"0,27 %"},{"name":"60 Hz 至 80 Hz","range":"10 mH 至 50 mH","cmc":"0,24 %"},{"name":"80 Hz 至 100 Hz","range":"10 mH 至 50 mH","cmc":"0,22 %"},{"name":"100 Hz 至 250 Hz","range":"10 mH 至 50 mH","cmc":"0,18 %"},{"name":"250 Hz 至 1 kHz","range":"10 mH 至 50 mH","cmc":"0,12 %"},{"name":"1 kHz 至 30 kHz","range":"10 mH 至 50 mH","cmc":"0,11 %"},{"name":"30 kHz 至 100 kHz","range":"10 mH 至 50 mH","cmc":"0,17 %"},{"name":"100 kHz 至 200 kHz","range":"10 mH 至 50 mH","cmc":"0,21 %"},{"name":"200 kHz 至 300 kHz","range":"10 mH 至 50 mH","cmc":"0,23 %"},{"name":"300 kHz 至 400 kHz","range":"10 mH 至 50 mH","cmc":"0,31 %"},{"name":"400 kHz 至 500 kHz","range":"10 mH 至 50 mH","cmc":"0,35 %"},{"name":"500 kHz 至 700 kHz","range":"10 mH 至 50 mH","cmc":"0,43 %"},{"name":"700 kHz 至 1 MHz","range":"10 mH 至 50 mH","cmc":"0,55 %"},{"name":"20 Hz 至 30 Hz","range":"50 mH 至 100 mH","cmc":"0,40 %"},{"name":"30 Hz 至 50 Hz","range":"50 mH 至 100 mH","cmc":"0,37 %"},{"name":"50 Hz 至 60 Hz","range":"50 mH 至 100 mH","cmc":"0,27 %"},{"name":"60 Hz 至 80 Hz","range":"50 mH 至 100 mH","cmc":"0,24 %"},{"name":"80 Hz 至 100 Hz","range":"50 mH 至 100 mH","cmc":"0,22 %"},{"name":"100 Hz 至 250 Hz","range":"50 mH 至 100 mH","cmc":"0,18 %"},{"name":"250 Hz 至 1 kHz","range":"50 mH 至 100 mH","cmc":"0,12 %"},{"name":"1 kHz 至 30 kHz","range":"50 mH 至 100 mH","cmc":"0,11 %"},{"name":"30 kHz 至 100 kHz","range":"50 mH 至 100 mH","cmc":"0,17 %"},{"name":"100 kHz 至 200 kHz","range":"50 mH 至 100 mH","cmc":"0,21 %"},{"name":"200 kHz 至 300 kHz","range":"50 mH 至 100 mH","cmc":"0,23 %"},{"name":"300 kHz 至 400 kHz","range":"50 mH 至 100 mH","cmc":"0,47 %"},{"name":"400 kHz 至 500 kHz","range":"50 mH 至 100 mH","cmc":"0,55 %"},{"name":"500 kHz 至 600 kHz","range":"50 mH 至 100 mH","cmc":"0,62 %"},{"name":"600 kHz 至 700 kHz","range":"50 mH 至 100 mH","cmc":"0,70 %"},{"name":"700 kHz 至 800 kHz","range":"50 mH 至 100 mH","cmc":"0,78 %"},{"name":"800 kHz 至 1 MHz","range":"50 mH 至 100 mH","cmc":"0,93 %"},{"name":"20 Hz 至 30 Hz","range":"100 mH 至 500 mH","cmc":"0,27 %"},{"name":"30 Hz 至 50 Hz","range":"100 mH 至 500 mH","cmc":"0,35 %"},{"name":"50 Hz 至 100 Hz","range":"100 mH 至 500 mH","cmc":"0,18 %"},{"name":"100 Hz 至 1 kHz","range":"100 mH 至 500 mH","cmc":"0,12 %"},{"name":"1 kHz 至 30 kHz","range":"100 mH 至 500 mH","cmc":"0,13 %"},{"name":"30 kHz 至 60 kHz","range":"100 mH 至 500 mH","cmc":"0,21 %"},{"name":"60 kHz 至 100 kHz","range":"100 mH 至 500 mH","cmc":"0,24 %"},{"name":"100 kHz 至 150 kHz","range":"100 mH 至 500 mH","cmc":"0,33 %"},{"name":"150 kHz 至 200 kHz","range":"100 mH 至 500 mH","cmc":"0,39 %"},{"name":"200 kHz 至 250 kHz","range":"100 mH 至 500 mH","cmc":"0,45 %"},{"name":"250 kHz 至 300 kHz","range":"100 mH 至 500 mH","cmc":"0,51 %"},{"name":"300 kHz 至 400 kHz","range":"100 mH 至 500 mH","cmc":"1,8 %"},{"name":"400 kHz 至 500 kHz","range":"100 mH 至 500 mH","cmc":"2,1 %"},{"name":"500 kHz 至 600 kHz","range":"100 mH 至 500 mH","cmc":"2,5 %"},{"name":"600 kHz 至 700 kHz","range":"100 mH 至 500 mH","cmc":"2,9 %"},{"name":"700 kHz 至 800 kHz","range":"100 mH 至 500 mH","cmc":"3,3 %"},{"name":"800 kHz 至 900 kHz","range":"100 mH 至 500 mH","cmc":"3,7 %"},{"name":"900 kHz 至 1 MHz","range":"100 mH 至 500 mH","cmc":"4,1 %"},{"name":"20 Hz 至 30 Hz","range":"500 mH 至 1 H","cmc":"0,27 %"},{"name":"30 Hz 至 50 Hz","range":"500 mH 至 1 H","cmc":"0,35 %"},{"name":"50 Hz 至 100 Hz","range":"500 mH 至 1 H","cmc":"0,18 %"},{"name":"100 Hz 至 1 kHz","range":"500 mH 至 1 H","cmc":"0,12 %"},{"name":"1 kHz 至 30 kHz","range":"500 mH 至 1 H","cmc":"0,13 %"},{"name":"30 kHz 至 60 kHz","range":"500 mH 至 1 H","cmc":"0,21 %"},{"name":"60 kHz 至 100 kHz","range":"500 mH 至 1 H","cmc":"0,24 %"},{"name":"100 kHz 至 150 kHz","range":"500 mH 至 1 H","cmc":"0,51 %"},{"name":"150 kHz 至 200 kHz","range":"500 mH 至 1 H","cmc":"0,62 %"},{"name":"200 kHz 至 250 kHz","range":"500 mH 至 1 H","cmc":"0,74 %"},{"name":"250 kHz 至 300 kHz","range":"500 mH 至 1 H","cmc":"0,86 %"},{"name":"300 kHz 至 400 kHz","range":"500 mH 至 1 H","cmc":"3,3 %"},{"name":"400 kHz 至 500 kHz","range":"500 mH 至 1 H","cmc":"4,1 %"},{"name":"500 kHz 至 600 kHz","range":"500 mH 至 1 H","cmc":"4,9 %"},{"name":"600 kHz 至 700 kHz","range":"500 mH 至 1 H","cmc":"5,6 %"},{"name":"700 kHz 至 800 kHz","range":"500 mH 至 1 H","cmc":"6,4 %"},{"name":"800 kHz 至 900 kHz","range":"500 mH 至 1 H","cmc":"7,2 %"},{"name":"900 kHz 至 1 MHz","range":"500 mH 至 1 H","cmc":"8,0 %"},{"name":"20 Hz 至 50 Hz","range":"1 H 至 2 H","cmc":"0,34 %"},{"name":"50 Hz 至 100 Hz","range":"1 H 至 2 H","cmc":"0,18 %"},{"name":"100 Hz 至 1 kHz","range":"1 H 至 2 H","cmc":"0,12 %"},{"name":"1 kHz 至 5 kHz","range":"1 H 至 2 H","cmc":"0,15 %"},{"name":"5 kHz 至 10 kHz","range":"1 H 至 2 H","cmc":"0,24 %"},{"name":"10 kHz 至 15 kHz","range":"1 H 至 2 H","cmc":"0,28 %"},{"name":"15 kHz 至 20 kHz","range":"1 H 至 2 H","cmc":"0,31 %"},{"name":"20 kHz 至 25 kHz","range":"1 H 至 2 H","cmc":"0,35 %"},{"name":"25 kHz 至 30 kHz","range":"1 H 至 2 H","cmc":"0,38 %"},{"name":"30 kHz 至 50 kHz","range":"1 H 至 2 H","cmc":"0,35 %"},{"name":"50 kHz 至 70 kHz","range":"1 H 至 2 H","cmc":"0,43 %"},{"name":"70 kHz 至 100 kHz","range":"1 H 至 2 H","cmc":"0,55 %"},{"name":"100 kHz 至 150 kHz","range":"1 H 至 2 H","cmc":"1,9 %"},{"name":"150 kHz 至 200 kHz","range":"1 H 至 2 H","cmc":"2,5 %"},{"name":"200 kHz 至 250 kHz","range":"1 H 至 2 H","cmc":"3,1 %"},{"name":"250 kHz 至 300 kHz","range":"1 H 至 2 H","cmc":"3,7 %"},{"name":"300 kHz 至 400 kHz","range":"1 H 至 2 H","cmc":"6,4 %"},{"name":"400 kHz 至 500 kHz","range":"1 H 至 2 H","cmc":"8,0 %"},{"name":"20 Hz 至 50 Hz","range":"2 H 至 5 H","cmc":"0,34 %"},{"name":"50 Hz 至 100 Hz","range":"2 H 至 5 H","cmc":"0,18 %"},{"name":"100 Hz 至 1 kHz","range":"2 H 至 5 H","cmc":"0,12 %"},{"name":"1 kHz 至 5 kHz","range":"2 H 至 5 H","cmc":"0,15 %"},{"name":"5 kHz 至 10 kHz","range":"2 H 至 5 H","cmc":"0,24 %"},{"name":"10 kHz 至 15 kHz","range":"2 H 至 5 H","cmc":"0,28 %"},{"name":"15 kHz 至 20 kHz","range":"2 H 至 5 H","cmc":"0,31 %"},{"name":"20 kHz 至 25 kHz","range":"2 H 至 5 H","cmc":"0,35 %"},{"name":"25 kHz 至 30 kHz","range":"2 H 至 5 H","cmc":"0,38 %"},{"name":"30 kHz 至 50 kHz","range":"2 H 至 5 H","cmc":"0,35 %"},{"name":"50 kHz 至 70 kHz","range":"2 H 至 5 H","cmc":"0,43 %"},{"name":"70 kHz 至 100 kHz","range":"2 H 至 5 H","cmc":"0,55 %"},{"name":"100 kHz 至 150 kHz","range":"2 H 至 5 H","cmc":"1,9 %"},{"name":"150 kHz 至 200 kHz","range":"2 H 至 5 H","cmc":"2,5 %"},{"name":"200 kHz 至 250 kHz","range":"2 H 至 5 H","cmc":"3,1 %"},{"name":"250 kHz 至 300 kHz","range":"2 H 至 5 H","cmc":"3,7 %"},{"name":"50 Hz 至 100 Hz","range":"5 H 至 10 H","cmc":"0,18 %"},{"name":"100 Hz 至 1 kHz","range":"5 H 至 10 H","cmc":"0,12 %"},{"name":"1 kHz 至 5 kHz","range":"5 H 至 10 H","cmc":"0,15 %"},{"name":"5 kHz 至 10 kHz","range":"5 H 至 10 H","cmc":"0,24 %"},{"name":"10 kHz 至 15 kHz","range":"5 H 至 10 H","cmc":"0,28 %"},{"name":"15 kHz 至 20 kHz","range":"5 H 至 10 H","cmc":"0,31 %"},{"name":"20 kHz 至 25 kHz","range":"5 H 至 10 H","cmc":"0,35 %"},{"name":"25 kHz 至 30 kHz","range":"5 H 至 10 H","cmc":"0,38 %"},{"name":"30 kHz 至 40 kHz","range":"5 H 至 10 H","cmc":"0,47 %"},{"name":"40 kHz 至 50 kHz","range":"5 H 至 10 H","cmc":"0,55 %"},{"name":"50 kHz 至 60 kHz","range":"5 H 至 10 H","cmc":"0,62 %"},{"name":"60 kHz 至 70 kHz","range":"5 H 至 10 H","cmc":"0,70 %"},{"name":"70 kHz 至 80 kHz","range":"5 H 至 10 H","cmc":"0,78 %"},{"name":"80 kHz 至 90 kHz","range":"5 H 至 10 H","cmc":"0,86 %"},{"name":"90 kHz 至 100 kHz","range":"5 H 至 10 H","cmc":"0,93 %"},{"name":"100 kHz 至 150 kHz","range":"5 H 至 10 H","cmc":"3,7 %"},{"name":"150 kHz 至 200 kHz","range":"5 H 至 10 H","cmc":"4,9 %"},{"name":"200 kHz 至 250 kHz","range":"5 H 至 10 H","cmc":"6,0 %"},{"name":"250 kHz 至 300 kHz","range":"5 H 至 10 H","cmc":"7,2 %"},{"name":"50 Hz 至 100 Hz","range":"10 H 至 50 H","cmc":"0,18 %"},{"name":"100 Hz 至 500 Hz","range":"10 H 至 50 H","cmc":"0,15 %"},{"name":"500 Hz 至 800 Hz","range":"10 H 至 50 H","cmc":"0,22 %"},{"name":"800 Hz 至 2 kHz","range":"10 H 至 50 H","cmc":"0,24 %"},{"name":"2 kHz 至 3 kHz","range":"10 H 至 50 H","cmc":"0,28 %"},{"name":"3 kHz 至 5 kHz","range":"10 H 至 50 H","cmc":"0,35 %"},{"name":"5 kHz 至 7 kHz","range":"10 H 至 50 H","cmc":"0,43 %"},{"name":"7 kHz 至 10 kHz","range":"10 H 至 50 H","cmc":"0,55 %"},{"name":"10 kHz 至 15 kHz","range":"10 H 至 50 H","cmc":"0,74 %"},{"name":"15 kHz 至 20 kHz","range":"10 H 至 50 H","cmc":"0,93 %"},{"name":"20 kHz 至 25 kHz","range":"10 H 至 50 H","cmc":"1,2 %"},{"name":"25 kHz 至 30 kHz","range":"10 H 至 50 H","cmc":"1,4 %"},{"name":"30 kHz 至 40 kHz","range":"10 H 至 50 H","cmc":"1,8 %"},{"name":"40 kHz 至 50 kHz","range":"10 H 至 50 H","cmc":"2,1 %"},{"name":"50 kHz 至 60 kHz","range":"10 H 至 50 H","cmc":"2,5 %"},{"name":"60 kHz 至 70 kHz","range":"10 H 至 50 H","cmc":"2,9 %"},{"name":"70 kHz 至 80 kHz","range":"10 H 至 50 H","cmc":"3,3 %"},{"name":"80 kHz 至 90 kHz","range":"10 H 至 50 H","cmc":"3,7 %"},{"name":"90 kHz 至 100 kHz","range":"10 H 至 50 H","cmc":"4,1 %"},{"name":"50 Hz 至 100 Hz","range":"50 H 至 100 H","cmc":"0,18 %"},{"name":"100 Hz 至 500 Hz","range":"50 H 至 100 H","cmc":"0,15 %"},{"name":"500 Hz 至 800 Hz","range":"50 H 至 100 H","cmc":"0,22 %"},{"name":"800 Hz 至 1 kHz","range":"50 H 至 100 H","cmc":"0,24 %"},{"name":"1 kHz 至 2 kHz","range":"50 H 至 100 H","cmc":"0,31 %"},{"name":"2 kHz 至 3 kHz","range":"50 H 至 100 H","cmc":"0,39 %"},{"name":"3 kHz 至 5 kHz","range":"50 H 至 100 H","cmc":"0,55 %"},{"name":"5 kHz 至 7 kHz","range":"50 H 至 100 H","cmc":"0,70 %"},{"name":"7 kHz 至 10 kHz","range":"50 H 至 100 H","cmc":"0,93 %"},{"name":"10 kHz 至 15 kHz","range":"50 H 至 100 H","cmc":"1,4 %"},{"name":"15 kHz 至 20 kHz","range":"50 H 至 100 H","cmc":"1,8 %"},{"name":"20 kHz 至 25 kHz","range":"50 H 至 100 H","cmc":"2,1 %"},{"name":"25 kHz 至 30 kHz","range":"50 H 至 100 H","cmc":"2,5 %"},{"name":"20 Hz 至 35 Hz","range":"100 H 至 500 H","cmc":"0,38 %"},{"name":"35 Hz 至 50 Hz","range":"100 H 至 500 H","cmc":"0,40 %"},{"name":"50 Hz 至 70 Hz","range":"100 H 至 500 H","cmc":"0,28 %"},{"name":"70 Hz 至 200 Hz","range":"100 H 至 500 H","cmc":"0,31 %"},{"name":"200 Hz 至 300 Hz","range":"100 H 至 500 H","cmc":"0,39 %"},{"name":"300 Hz 至 400 Hz","range":"100 H 至 500 H","cmc":"0,47 %"},{"name":"400 Hz 至 500 Hz","range":"100 H 至 500 H","cmc":"0,55 %"},{"name":"500 Hz 至 600 Hz","range":"100 H 至 500 H","cmc":"0,62 %"},{"name":"600 Hz 至 700 Hz","range":"100 H 至 500 H","cmc":"0,70 %"},{"name":"700 Hz 至 800 Hz","range":"100 H 至 500 H","cmc":"0,78 %"},{"name":"800 Hz 至 900 Hz","range":"100 H 至 500 H","cmc":"0,86 %"},{"name":"900 Hz 至 2 kHz","range":"100 H 至 500 H","cmc":"0,93 %"},{"name":"2 kHz 至 3 kHz","range":"100 H 至 500 H","cmc":"1,4 %"},{"name":"3 kHz 至 5 kHz","range":"100 H 至 500 H","cmc":"2,1 %"},{"name":"5 kHz 至 7 kHz","range":"100 H 至 500 H","cmc":"2,9 %"},{"name":"7 kHz 至 8 kHz","range":"100 H 至 500 H","cmc":"3,3 %"},{"name":"8 kHz 至 9 kHz","range":"100 H 至 500 H","cmc":"3,7 %"},{"name":"9 kHz 至 10 kHz","range":"100 H 至 500 H","cmc":"4,1 %"},{"name":"20 Hz 至 35 Hz","range":"500 H 至 1 kH","cmc":"0,38 %"},{"name":"35 Hz 至 50 Hz","range":"500 H 至 1 kH","cmc":"0,40 %"},{"name":"50 Hz 至 70 Hz","range":"500 H 至 1 kH","cmc":"0,28 %"},{"name":"70 Hz 至 100 Hz","range":"500 H 至 1 kH","cmc":"0,31 %"},{"name":"100 Hz 至 200 Hz","range":"500 H 至 1 kH","cmc":"0,31 %"},{"name":"200 Hz 至 300 Hz","range":"500 H 至 1 kH","cmc":"0,39 %"},{"name":"300 Hz 至 400 Hz","range":"500 H 至 1 kH","cmc":"0,47 %"},{"name":"400 Hz 至 500 Hz","range":"500 H 至 1 kH","cmc":"0,55 %"},{"name":"500 Hz 至 600 Hz","range":"500 H 至 1 kH","cmc":"0,62 %"},{"name":"600 Hz 至 700 Hz","range":"500 H 至 1 kH","cmc":"0,70 %"},{"name":"700 Hz 至 800 Hz","range":"500 H 至 1 kH","cmc":"0,78 %"},{"name":"800 Hz 至 900 Hz","range":"500 H 至 1 kH","cmc":"0,86 %"},{"name":"900 Hz 至 1 kHz","range":"500 H 至 1 kH","cmc":"0,93 %"}],"parameters_cs":[{"name":"10 kHz až 15 kHz","range":"1 µH až 5 µH","cmc":"2,4 %"},{"name":"15 kHz až 20 kHz","range":"1 µH až 5 µH","cmc":"1,7 %"},{"name":"20 kHz až 25 kHz","range":"1 µH až 5 µH","cmc":"1,3 %"},{"name":"25 kHz až 30 kHz","range":"1 µH až 5 µH","cmc":"1,1 %"},{"name":"30 kHz až 40 kHz","range":"1 µH až 5 µH","cmc":"0,89 %"},{"name":"40 kHz až 50 kHz","range":"1 µH až 5 µH","cmc":"0,71 %"},{"name":"50 kHz až 60 kHz","range":"1 µH až 5 µH","cmc":"0,60 %"},{"name":"60 kHz až 70 kHz","range":"1 µH až 5 µH","cmc":"0,53 %"},{"name":"70 kHz až 80 kHz","range":"1 µH až 5 µH","cmc":"0,47 %"},{"name":"80 kHz až 90 kHz","range":"1 µH až 5 µH","cmc":"0,43 %"},{"name":"90 kHz až 100 kHz","range":"1 µH až 5 µH","cmc":"0,40 %"},{"name":"100 kHz až 150 kHz","range":"1 µH až 5 µH","cmc":"0,56 %"},{"name":"150 kHz až 200 kHz","range":"1 µH až 5 µH","cmc":"0,45 %"},{"name":"200 kHz až 250 kHz","range":"1 µH až 5 µH","cmc":"0,36 %"},{"name":"250 kHz až 300 kHz","range":"1 µH až 5 µH","cmc":"0,32 %"},{"name":"300 kHz až 400 kHz","range":"1 µH až 5 µH","cmc":"0,36 %"},{"name":"400 kHz až 500 kHz","range":"1 µH až 5 µH","cmc":"0,31 %"},{"name":"500 kHz až 700 kHz","range":"1 µH až 5 µH","cmc":"0,28 %"},{"name":"700 kHz až 1 MHz","range":"1 µH až 5 µH","cmc":"0,24 %"},{"name":"2 kHz až 3 kHz","range":"5 µH až 10 µH","cmc":"2,4 %"},{"name":"3 kHz až 5 kHz","range":"5 µH až 10 µH","cmc":"1,7 %"},{"name":"5 kHz až 7 kHz","range":"5 µH až 10 µH","cmc":"1,1 %"},{"name":"7 kHz až 10 kHz","range":"5 µH až 10 µH","cmc":"0,79 %"},{"name":"10 kHz až 15 kHz","range":"5 µH až 10 µH","cmc":"0,60 %"},{"name":"15 kHz až 20 kHz","range":"5 µH až 10 µH","cmc":"0,45 %"},{"name":"20 kHz až 25 kHz","range":"5 µH až 10 µH","cmc":"0,38 %"},{"name":"25 kHz až 30 kHz","range":"5 µH až 10 µH","cmc":"0,34 %"},{"name":"30 kHz až 40 kHz","range":"5 µH až 10 µH","cmc":"0,31 %"},{"name":"40 kHz až 50 kHz","range":"5 µH až 10 µH","cmc":"0,27 %"},{"name":"50 kHz až 60 kHz","range":"5 µH až 10 µH","cmc":"0,25 %"},{"name":"60 kHz až 100 kHz","range":"5 µH až 10 µH","cmc":"0,23 %"},{"name":"100 kHz až 150 kHz","range":"5 µH až 10 µH","cmc":"0,24 %"},{"name":"150 kHz až 200 kHz","range":"5 µH až 10 µH","cmc":"0,22 %"},{"name":"200 kHz až 500 kHz","range":"5 µH až 10 µH","cmc":"0,20 %"},{"name":"500 kHz až 1 MHz","range":"5 µH až 10 µH","cmc":"0,13 %"},{"name":"1 kHz až 2 kHz","range":"10 µH až 50 µH","cmc":"2,4 %"},{"name":"2 kHz až 3 kHz","range":"10 µH až 50 µH","cmc":"1,3 %"},{"name":"3 kHz až 5 kHz","range":"10 µH až 50 µH","cmc":"0,89 %"},{"name":"5 kHz až 7 kHz","range":"10 µH až 50 µH","cmc":"0,60 %"},{"name":"7 kHz až 10 kHz","range":"10 µH až 50 µH","cmc":"0,47 %"},{"name":"10 kHz až 15 kHz","range":"10 µH až 50 µH","cmc":"0,38 %"},{"name":"15 kHz až 20 kHz","range":"10 µH až 50 µH","cmc":"0,31 %"},{"name":"20 kHz až 25 kHz","range":"10 µH až 50 µH","cmc":"0,27 %"},{"name":"25 kHz až 30 kHz","range":"10 µH až 50 µH","cmc":"0,25 %"},{"name":"30 kHz až 50 kHz","range":"10 µH až 50 µH","cmc":"0,23 %"},{"name":"50 kHz až 70 kHz","range":"10 µH až 50 µH","cmc":"0,21 %"},{"name":"70 kHz až 100 kHz","range":"10 µH až 50 µH","cmc":"0,19 %"},{"name":"100 kHz až 250 kHz","range":"10 µH až 50 µH","cmc":"0,20 %"},{"name":"250 kHz až 300 kHz","range":"10 µH až 50 µH","cmc":"0,12 %"},{"name":"300 kHz až 1 MHz","range":"10 µH až 50 µH","cmc":"0,13 %"},{"name":"200 Hz až 300 Hz","range":"50 µH až 100 µH","cmc":"2,6 %"},{"name":"300 Hz až 400 Hz","range":"50 µH až 100 µH","cmc":"1,8 %"},{"name":"400 Hz až 500 Hz","range":"50 µH až 100 µH","cmc":"1,3 %"},{"name":"500 Hz až 600 Hz","range":"50 µH až 100 µH","cmc":"1,1 %"},{"name":"600 Hz až 700 Hz","range":"50 µH až 100 µH","cmc":"0,89 %"},{"name":"700 Hz až 800 Hz","range":"50 µH až 100 µH","cmc":"0,79 %"},{"name":"800 Hz až 900 Hz","range":"50 µH až 100 µH","cmc":"0,71 %"},{"name":"900 Hz až 1 kHz","range":"50 µH až 100 µH","cmc":"0,65 %"},{"name":"1 kHz až 2 kHz","range":"50 µH až 100 µH","cmc":"0,60 %"},{"name":"2 kHz až 3 kHz","range":"50 µH až 100 µH","cmc":"0,38 %"},{"name":"3 kHz až 5 kHz","range":"50 µH až 100 µH","cmc":"0,31 %"},{"name":"5 kHz až 10 kHz","range":"50 µH až 100 µH","cmc":"0,25 %"},{"name":"10 kHz až 15 kHz","range":"50 µH až 100 µH","cmc":"0,21 %"},{"name":"15 kHz až 30 kHz","range":"50 µH až 100 µH","cmc":"0,19 %"},{"name":"30 kHz až 50 kHz","range":"50 µH až 100 µH","cmc":"0,18 %"},{"name":"50 kHz až 100 kHz","range":"50 µH až 100 µH","cmc":"0,12 %"},{"name":"100 kHz až 250 kHz","range":"50 µH až 100 µH","cmc":"0,20 %"},{"name":"250 kHz až 300 kHz","range":"50 µH až 100 µH","cmc":"0,12 %"},{"name":"300 kHz až 1 MHz","range":"50 µH až 100 µH","cmc":"0,13 %"},{"name":"80 Hz až 90 Hz","range":"100 µH až 500 µH","cmc":"6,2 %"},{"name":"90 Hz až 100 Hz","range":"100 µH až 500 µH","cmc":"5,4 %"},{"name":"100 Hz až 200 Hz","range":"100 µH až 500 µH","cmc":"2,6 %"},{"name":"200 Hz až 300 Hz","range":"100 µH až 500 µH","cmc":"1,3 %"},{"name":"300 Hz až 400 Hz","range":"100 µH až 500 µH","cmc":"0,89 %"},{"name":"400 Hz až 500 Hz","range":"100 µH až 500 µH","cmc":"0,71 %"},{"name":"500 Hz až 600 Hz","range":"100 µH až 500 µH","cmc":"0,60 %"},{"name":"600 Hz až 700 Hz","range":"100 µH až 500 µH","cmc":"0,53 %"},{"name":"700 Hz až 800 Hz","range":"100 µH až 500 µH","cmc":"0,47 %"},{"name":"800 Hz až 900 Hz","range":"100 µH až 500 µH","cmc":"0,43 %"},{"name":"900 Hz až 1 kHz","range":"100 µH až 500 µH","cmc":"0,40 %"},{"name":"1 kHz až 2 kHz","range":"100 µH až 500 µH","cmc":"0,38 %"},{"name":"2 kHz až 3 kHz","range":"100 µH až 500 µH","cmc":"0,27 %"},{"name":"3 kHz až 5 kHz","range":"100 µH až 500 µH","cmc":"0,23 %"},{"name":"5 kHz až 10 kHz","range":"100 µH až 500 µH","cmc":"0,21 %"},{"name":"10 kHz až 25 kHz","range":"100 µH až 500 µH","cmc":"0,18 %"},{"name":"25 kHz až 30 kHz","range":"100 µH až 500 µH","cmc":"0,12 %"},{"name":"30 kHz až 100 kHz","range":"100 µH až 500 µH","cmc":"0,12 %"},{"name":"100 kHz až 300 kHz","range":"100 µH až 500 µH","cmc":"0,11 %"},{"name":"300 kHz až 1 MHz","range":"100 µH až 500 µH","cmc":"0,17 %"},{"name":"50 Hz až 60 Hz","range":"500 µH až 1 mH","cmc":"2,3 %"},{"name":"60 Hz až 70 Hz","range":"500 µH až 1 mH","cmc":"1,9 %"},{"name":"70 Hz až 80 Hz","range":"500 µH až 1 mH","cmc":"1,6 %"},{"name":"80 Hz až 100 Hz","range":"500 µH až 1 mH","cmc":"1,4 %"},{"name":"100 Hz až 200 Hz","range":"500 µH až 1 mH","cmc":"0,60 %"},{"name":"200 Hz až 300 Hz","range":"500 µH až 1 mH","cmc":"0,38 %"},{"name":"300 Hz až 400 Hz","range":"500 µH až 1 mH","cmc":"0,31 %"},{"name":"400 Hz až 500 Hz","range":"500 µH až 1 mH","cmc":"0,27 %"},{"name":"500 Hz až 600 Hz","range":"500 µH až 1 mH","cmc":"0,25 %"},{"name":"600 Hz až 900 Hz","range":"500 µH až 1 mH","cmc":"0,23 %"},{"name":"900 Hz až 1 kHz","range":"500 µH až 1 mH","cmc":"0,21 %"},{"name":"1 kHz až 2 kHz","range":"500 µH až 1 mH","cmc":"0,38 %"},{"name":"2 kHz až 3 kHz","range":"500 µH až 1 mH","cmc":"0,27 %"},{"name":"3 kHz až 5 kHz","range":"500 µH až 1 mH","cmc":"0,23 %"},{"name":"5 kHz až 10 kHz","range":"500 µH až 1 mH","cmc":"0,21 %"},{"name":"10 kHz až 25 kHz","range":"500 µH až 1 mH","cmc":"0,18 %"},{"name":"25 kHz až 100 kHz","range":"500 µH až 1 mH","cmc":"0,12 %"},{"name":"100 kHz až 300 kHz","range":"500 µH až 1 mH","cmc":"0,11 %"},{"name":"300 kHz až 1 MHz","range":"500 µH až 1 mH","cmc":"0,17 %"},{"name":"20 Hz až 30 Hz","range":"1 mH až 5 mH","cmc":"3,9 %"},{"name":"30 Hz až 40 Hz","range":"1 mH až 5 mH","cmc":"2,5 %"},{"name":"40 Hz až 50 Hz","range":"1 mH až 5 mH","cmc":"1,8 %"},{"name":"50 Hz až 60 Hz","range":"1 mH až 5 mH","cmc":"1,3 %"},{"name":"60 Hz až 80 Hz","range":"1 mH až 5 mH","cmc":"1,0 %"},{"name":"80 Hz až 90 Hz","range":"1 mH až 5 mH","cmc":"0,74 %"},{"name":"90 Hz až 100 Hz","range":"1 mH až 5 mH","cmc":"0,66 %"},{"name":"100 Hz až 200 Hz","range":"1 mH až 5 mH","cmc":"0,38 %"},{"name":"200 Hz až 300 Hz","range":"1 mH až 5 mH","cmc":"0,27 %"},{"name":"300 Hz až 500 Hz","range":"1 mH až 5 mH","cmc":"0,23 %"},{"name":"500 Hz až 700 Hz","range":"1 mH až 5 mH","cmc":"0,21 %"},{"name":"700 Hz až 1 kHz","range":"1 mH až 5 mH","cmc":"0,19 %"},{"name":"1 kHz až 3 kHz","range":"1 mH až 5 mH","cmc":"0,18 %"},{"name":"3 kHz až 100 kHz","range":"1 mH až 5 mH","cmc":"0,12 %"},{"name":"100 kHz až 300 kHz","range":"1 mH až 5 mH","cmc":"0,17 %"},{"name":"300 kHz až 600 kHz","range":"1 mH až 5 mH","cmc":"0,21 %"},{"name":"600 kHz až 1 MHz","range":"1 mH až 5 mH","cmc":"0,24 %"},{"name":"20 Hz až 30 Hz","range":"5 mH až 10 mH","cmc":"1,1 %"},{"name":"30 Hz až 40 Hz","range":"5 mH až 10 mH","cmc":"0,75 %"},{"name":"40 Hz až 50 Hz","range":"5 mH až 10 mH","cmc":"0,61 %"},{"name":"50 Hz až 60 Hz","range":"5 mH až 10 mH","cmc":"0,37 %"},{"name":"60 Hz až 70 Hz","range":"5 mH až 10 mH","cmc":"0,33 %"},{"name":"70 Hz až 80 Hz","range":"5 mH až 10 mH","cmc":"0,30 %"},{"name":"80 Hz až 90 Hz","range":"5 mH až 10 mH","cmc":"0,28 %"},{"name":"90 Hz až 100 Hz","range":"5 mH až 10 mH","cmc":"0,26 %"},{"name":"100 Hz až 200 Hz","range":"5 mH až 10 mH","cmc":"0,38 %"},{"name":"200 Hz až 300 Hz","range":"5 mH až 10 mH","cmc":"0,27 %"},{"name":"300 Hz až 500 Hz","range":"5 mH až 10 mH","cmc":"0,23 %"},{"name":"500 Hz až 700 Hz","range":"5 mH až 10 mH","cmc":"0,21 %"},{"name":"700 Hz až 1 kHz","range":"5 mH až 10 mH","cmc":"0,19 %"},{"name":"1 kHz až 3 kHz","range":"5 mH až 10 mH","cmc":"0,18 %"},{"name":"3 kHz až 100 kHz","range":"5 mH až 10 mH","cmc":"0,12 %"},{"name":"100 kHz až 300 kHz","range":"5 mH až 10 mH","cmc":"0,17 %"},{"name":"300 kHz až 600 kHz","range":"5 mH až 10 mH","cmc":"0,21 %"},{"name":"600 kHz až 1 MHz","range":"5 mH až 10 mH","cmc":"0,24 %"},{"name":"20 Hz až 30 Hz","range":"10 mH až 50 mH","cmc":"0,69 %"},{"name":"30 Hz až 40 Hz","range":"10 mH až 50 mH","cmc":"0,54 %"},{"name":"40 Hz až 50 Hz","range":"10 mH až 50 mH","cmc":"0,47 %"},{"name":"50 Hz až 60 Hz","range":"10 mH až 50 mH","cmc":"0,27 %"},{"name":"60 Hz až 80 Hz","range":"10 mH až 50 mH","cmc":"0,24 %"},{"name":"80 Hz až 100 Hz","range":"10 mH až 50 mH","cmc":"0,22 %"},{"name":"100 Hz až 250 Hz","range":"10 mH až 50 mH","cmc":"0,18 %"},{"name":"250 Hz až 1 kHz","range":"10 mH až 50 mH","cmc":"0,12 %"},{"name":"1 kHz až 30 kHz","range":"10 mH až 50 mH","cmc":"0,11 %"},{"name":"30 kHz až 100 kHz","range":"10 mH až 50 mH","cmc":"0,17 %"},{"name":"100 kHz až 200 kHz","range":"10 mH až 50 mH","cmc":"0,21 %"},{"name":"200 kHz až 300 kHz","range":"10 mH až 50 mH","cmc":"0,23 %"},{"name":"300 kHz až 400 kHz","range":"10 mH až 50 mH","cmc":"0,31 %"},{"name":"400 kHz až 500 kHz","range":"10 mH až 50 mH","cmc":"0,35 %"},{"name":"500 kHz až 700 kHz","range":"10 mH až 50 mH","cmc":"0,43 %"},{"name":"700 kHz až 1 MHz","range":"10 mH až 50 mH","cmc":"0,55 %"},{"name":"20 Hz až 30 Hz","range":"50 mH až 100 mH","cmc":"0,40 %"},{"name":"30 Hz až 50 Hz","range":"50 mH až 100 mH","cmc":"0,37 %"},{"name":"50 Hz až 60 Hz","range":"50 mH až 100 mH","cmc":"0,27 %"},{"name":"60 Hz až 80 Hz","range":"50 mH až 100 mH","cmc":"0,24 %"},{"name":"80 Hz až 100 Hz","range":"50 mH až 100 mH","cmc":"0,22 %"},{"name":"100 Hz až 250 Hz","range":"50 mH až 100 mH","cmc":"0,18 %"},{"name":"250 Hz až 1 kHz","range":"50 mH až 100 mH","cmc":"0,12 %"},{"name":"1 kHz až 30 kHz","range":"50 mH až 100 mH","cmc":"0,11 %"},{"name":"30 kHz až 100 kHz","range":"50 mH až 100 mH","cmc":"0,17 %"},{"name":"100 kHz až 200 kHz","range":"50 mH až 100 mH","cmc":"0,21 %"},{"name":"200 kHz až 300 kHz","range":"50 mH až 100 mH","cmc":"0,23 %"},{"name":"300 kHz až 400 kHz","range":"50 mH až 100 mH","cmc":"0,47 %"},{"name":"400 kHz až 500 kHz","range":"50 mH až 100 mH","cmc":"0,55 %"},{"name":"500 kHz až 600 kHz","range":"50 mH až 100 mH","cmc":"0,62 %"},{"name":"600 kHz až 700 kHz","range":"50 mH až 100 mH","cmc":"0,70 %"},{"name":"700 kHz až 800 kHz","range":"50 mH až 100 mH","cmc":"0,78 %"},{"name":"800 kHz až 1 MHz","range":"50 mH až 100 mH","cmc":"0,93 %"},{"name":"20 Hz až 30 Hz","range":"100 mH až 500 mH","cmc":"0,27 %"},{"name":"30 Hz až 50 Hz","range":"100 mH až 500 mH","cmc":"0,35 %"},{"name":"50 Hz až 100 Hz","range":"100 mH až 500 mH","cmc":"0,18 %"},{"name":"100 Hz až 1 kHz","range":"100 mH až 500 mH","cmc":"0,12 %"},{"name":"1 kHz až 30 kHz","range":"100 mH až 500 mH","cmc":"0,13 %"},{"name":"30 kHz až 60 kHz","range":"100 mH až 500 mH","cmc":"0,21 %"},{"name":"60 kHz až 100 kHz","range":"100 mH až 500 mH","cmc":"0,24 %"},{"name":"100 kHz až 150 kHz","range":"100 mH až 500 mH","cmc":"0,33 %"},{"name":"150 kHz až 200 kHz","range":"100 mH až 500 mH","cmc":"0,39 %"},{"name":"200 kHz až 250 kHz","range":"100 mH až 500 mH","cmc":"0,45 %"},{"name":"250 kHz až 300 kHz","range":"100 mH až 500 mH","cmc":"0,51 %"},{"name":"300 kHz až 400 kHz","range":"100 mH až 500 mH","cmc":"1,8 %"},{"name":"400 kHz až 500 kHz","range":"100 mH až 500 mH","cmc":"2,1 %"},{"name":"500 kHz až 600 kHz","range":"100 mH až 500 mH","cmc":"2,5 %"},{"name":"600 kHz až 700 kHz","range":"100 mH až 500 mH","cmc":"2,9 %"},{"name":"700 kHz až 800 kHz","range":"100 mH až 500 mH","cmc":"3,3 %"},{"name":"800 kHz až 900 kHz","range":"100 mH až 500 mH","cmc":"3,7 %"},{"name":"900 kHz až 1 MHz","range":"100 mH až 500 mH","cmc":"4,1 %"},{"name":"20 Hz až 30 Hz","range":"500 mH až 1 H","cmc":"0,27 %"},{"name":"30 Hz až 50 Hz","range":"500 mH až 1 H","cmc":"0,35 %"},{"name":"50 Hz až 100 Hz","range":"500 mH až 1 H","cmc":"0,18 %"},{"name":"100 Hz až 1 kHz","range":"500 mH až 1 H","cmc":"0,12 %"},{"name":"1 kHz až 30 kHz","range":"500 mH až 1 H","cmc":"0,13 %"},{"name":"30 kHz až 60 kHz","range":"500 mH až 1 H","cmc":"0,21 %"},{"name":"60 kHz až 100 kHz","range":"500 mH až 1 H","cmc":"0,24 %"},{"name":"100 kHz až 150 kHz","range":"500 mH až 1 H","cmc":"0,51 %"},{"name":"150 kHz až 200 kHz","range":"500 mH až 1 H","cmc":"0,62 %"},{"name":"200 kHz až 250 kHz","range":"500 mH až 1 H","cmc":"0,74 %"},{"name":"250 kHz až 300 kHz","range":"500 mH až 1 H","cmc":"0,86 %"},{"name":"300 kHz až 400 kHz","range":"500 mH až 1 H","cmc":"3,3 %"},{"name":"400 kHz až 500 kHz","range":"500 mH až 1 H","cmc":"4,1 %"},{"name":"500 kHz až 600 kHz","range":"500 mH až 1 H","cmc":"4,9 %"},{"name":"600 kHz až 700 kHz","range":"500 mH až 1 H","cmc":"5,6 %"},{"name":"700 kHz až 800 kHz","range":"500 mH až 1 H","cmc":"6,4 %"},{"name":"800 kHz až 900 kHz","range":"500 mH až 1 H","cmc":"7,2 %"},{"name":"900 kHz až 1 MHz","range":"500 mH až 1 H","cmc":"8,0 %"},{"name":"20 Hz až 50 Hz","range":"1 H až 2 H","cmc":"0,34 %"},{"name":"50 Hz až 100 Hz","range":"1 H až 2 H","cmc":"0,18 %"},{"name":"100 Hz až 1 kHz","range":"1 H až 2 H","cmc":"0,12 %"},{"name":"1 kHz až 5 kHz","range":"1 H až 2 H","cmc":"0,15 %"},{"name":"5 kHz až 10 kHz","range":"1 H až 2 H","cmc":"0,24 %"},{"name":"10 kHz až 15 kHz","range":"1 H až 2 H","cmc":"0,28 %"},{"name":"15 kHz až 20 kHz","range":"1 H až 2 H","cmc":"0,31 %"},{"name":"20 kHz až 25 kHz","range":"1 H až 2 H","cmc":"0,35 %"},{"name":"25 kHz až 30 kHz","range":"1 H až 2 H","cmc":"0,38 %"},{"name":"30 kHz až 50 kHz","range":"1 H až 2 H","cmc":"0,35 %"},{"name":"50 kHz až 70 kHz","range":"1 H až 2 H","cmc":"0,43 %"},{"name":"70 kHz až 100 kHz","range":"1 H až 2 H","cmc":"0,55 %"},{"name":"100 kHz až 150 kHz","range":"1 H až 2 H","cmc":"1,9 %"},{"name":"150 kHz až 200 kHz","range":"1 H až 2 H","cmc":"2,5 %"},{"name":"200 kHz až 250 kHz","range":"1 H až 2 H","cmc":"3,1 %"},{"name":"250 kHz až 300 kHz","range":"1 H až 2 H","cmc":"3,7 %"},{"name":"300 kHz až 400 kHz","range":"1 H až 2 H","cmc":"6,4 %"},{"name":"400 kHz až 500 kHz","range":"1 H až 2 H","cmc":"8,0 %"},{"name":"20 Hz až 50 Hz","range":"2 H až 5 H","cmc":"0,34 %"},{"name":"50 Hz až 100 Hz","range":"2 H až 5 H","cmc":"0,18 %"},{"name":"100 Hz až 1 kHz","range":"2 H až 5 H","cmc":"0,12 %"},{"name":"1 kHz až 5 kHz","range":"2 H až 5 H","cmc":"0,15 %"},{"name":"5 kHz až 10 kHz","range":"2 H až 5 H","cmc":"0,24 %"},{"name":"10 kHz až 15 kHz","range":"2 H až 5 H","cmc":"0,28 %"},{"name":"15 kHz až 20 kHz","range":"2 H až 5 H","cmc":"0,31 %"},{"name":"20 kHz až 25 kHz","range":"2 H až 5 H","cmc":"0,35 %"},{"name":"25 kHz až 30 kHz","range":"2 H až 5 H","cmc":"0,38 %"},{"name":"30 kHz až 50 kHz","range":"2 H až 5 H","cmc":"0,35 %"},{"name":"50 kHz až 70 kHz","range":"2 H až 5 H","cmc":"0,43 %"},{"name":"70 kHz až 100 kHz","range":"2 H až 5 H","cmc":"0,55 %"},{"name":"100 kHz až 150 kHz","range":"2 H až 5 H","cmc":"1,9 %"},{"name":"150 kHz až 200 kHz","range":"2 H až 5 H","cmc":"2,5 %"},{"name":"200 kHz až 250 kHz","range":"2 H až 5 H","cmc":"3,1 %"},{"name":"250 kHz až 300 kHz","range":"2 H až 5 H","cmc":"3,7 %"},{"name":"50 Hz až 100 Hz","range":"5 H až 10 H","cmc":"0,18 %"},{"name":"100 Hz až 1 kHz","range":"5 H až 10 H","cmc":"0,12 %"},{"name":"1 kHz až 5 kHz","range":"5 H až 10 H","cmc":"0,15 %"},{"name":"5 kHz až 10 kHz","range":"5 H až 10 H","cmc":"0,24 %"},{"name":"10 kHz až 15 kHz","range":"5 H až 10 H","cmc":"0,28 %"},{"name":"15 kHz až 20 kHz","range":"5 H až 10 H","cmc":"0,31 %"},{"name":"20 kHz až 25 kHz","range":"5 H až 10 H","cmc":"0,35 %"},{"name":"25 kHz až 30 kHz","range":"5 H až 10 H","cmc":"0,38 %"},{"name":"30 kHz až 40 kHz","range":"5 H až 10 H","cmc":"0,47 %"},{"name":"40 kHz až 50 kHz","range":"5 H až 10 H","cmc":"0,55 %"},{"name":"50 kHz až 60 kHz","range":"5 H až 10 H","cmc":"0,62 %"},{"name":"60 kHz až 70 kHz","range":"5 H až 10 H","cmc":"0,70 %"},{"name":"70 kHz až 80 kHz","range":"5 H až 10 H","cmc":"0,78 %"},{"name":"80 kHz až 90 kHz","range":"5 H až 10 H","cmc":"0,86 %"},{"name":"90 kHz až 100 kHz","range":"5 H až 10 H","cmc":"0,93 %"},{"name":"100 kHz až 150 kHz","range":"5 H až 10 H","cmc":"3,7 %"},{"name":"150 kHz až 200 kHz","range":"5 H až 10 H","cmc":"4,9 %"},{"name":"200 kHz až 250 kHz","range":"5 H až 10 H","cmc":"6,0 %"},{"name":"250 kHz až 300 kHz","range":"5 H až 10 H","cmc":"7,2 %"},{"name":"50 Hz až 100 Hz","range":"10 H až 50 H","cmc":"0,18 %"},{"name":"100 Hz až 500 Hz","range":"10 H až 50 H","cmc":"0,15 %"},{"name":"500 Hz až 800 Hz","range":"10 H až 50 H","cmc":"0,22 %"},{"name":"800 Hz až 2 kHz","range":"10 H až 50 H","cmc":"0,24 %"},{"name":"2 kHz až 3 kHz","range":"10 H až 50 H","cmc":"0,28 %"},{"name":"3 kHz až 5 kHz","range":"10 H až 50 H","cmc":"0,35 %"},{"name":"5 kHz až 7 kHz","range":"10 H až 50 H","cmc":"0,43 %"},{"name":"7 kHz až 10 kHz","range":"10 H až 50 H","cmc":"0,55 %"},{"name":"10 kHz až 15 kHz","range":"10 H až 50 H","cmc":"0,74 %"},{"name":"15 kHz až 20 kHz","range":"10 H až 50 H","cmc":"0,93 %"},{"name":"20 kHz až 25 kHz","range":"10 H až 50 H","cmc":"1,2 %"},{"name":"25 kHz až 30 kHz","range":"10 H až 50 H","cmc":"1,4 %"},{"name":"30 kHz až 40 kHz","range":"10 H až 50 H","cmc":"1,8 %"},{"name":"40 kHz až 50 kHz","range":"10 H až 50 H","cmc":"2,1 %"},{"name":"50 kHz až 60 kHz","range":"10 H až 50 H","cmc":"2,5 %"},{"name":"60 kHz až 70 kHz","range":"10 H až 50 H","cmc":"2,9 %"},{"name":"70 kHz až 80 kHz","range":"10 H až 50 H","cmc":"3,3 %"},{"name":"80 kHz až 90 kHz","range":"10 H až 50 H","cmc":"3,7 %"},{"name":"90 kHz až 100 kHz","range":"10 H až 50 H","cmc":"4,1 %"},{"name":"50 Hz až 100 Hz","range":"50 H až 100 H","cmc":"0,18 %"},{"name":"100 Hz až 500 Hz","range":"50 H až 100 H","cmc":"0,15 %"},{"name":"500 Hz až 800 Hz","range":"50 H až 100 H","cmc":"0,22 %"},{"name":"800 Hz až 1 kHz","range":"50 H až 100 H","cmc":"0,24 %"},{"name":"1 kHz až 2 kHz","range":"50 H až 100 H","cmc":"0,31 %"},{"name":"2 kHz až 3 kHz","range":"50 H až 100 H","cmc":"0,39 %"},{"name":"3 kHz až 5 kHz","range":"50 H až 100 H","cmc":"0,55 %"},{"name":"5 kHz až 7 kHz","range":"50 H až 100 H","cmc":"0,70 %"},{"name":"7 kHz až 10 kHz","range":"50 H až 100 H","cmc":"0,93 %"},{"name":"10 kHz až 15 kHz","range":"50 H až 100 H","cmc":"1,4 %"},{"name":"15 kHz až 20 kHz","range":"50 H až 100 H","cmc":"1,8 %"},{"name":"20 kHz až 25 kHz","range":"50 H až 100 H","cmc":"2,1 %"},{"name":"25 kHz až 30 kHz","range":"50 H až 100 H","cmc":"2,5 %"},{"name":"20 Hz až 35 Hz","range":"100 H až 500 H","cmc":"0,38 %"},{"name":"35 Hz až 50 Hz","range":"100 H až 500 H","cmc":"0,40 %"},{"name":"50 Hz až 70 Hz","range":"100 H až 500 H","cmc":"0,28 %"},{"name":"70 Hz až 200 Hz","range":"100 H až 500 H","cmc":"0,31 %"},{"name":"200 Hz až 300 Hz","range":"100 H až 500 H","cmc":"0,39 %"},{"name":"300 Hz až 400 Hz","range":"100 H až 500 H","cmc":"0,47 %"},{"name":"400 Hz až 500 Hz","range":"100 H až 500 H","cmc":"0,55 %"},{"name":"500 Hz až 600 Hz","range":"100 H až 500 H","cmc":"0,62 %"},{"name":"600 Hz až 700 Hz","range":"100 H až 500 H","cmc":"0,70 %"},{"name":"700 Hz až 800 Hz","range":"100 H až 500 H","cmc":"0,78 %"},{"name":"800 Hz až 900 Hz","range":"100 H až 500 H","cmc":"0,86 %"},{"name":"900 Hz až 2 kHz","range":"100 H až 500 H","cmc":"0,93 %"},{"name":"2 kHz až 3 kHz","range":"100 H až 500 H","cmc":"1,4 %"},{"name":"3 kHz až 5 kHz","range":"100 H až 500 H","cmc":"2,1 %"},{"name":"5 kHz až 7 kHz","range":"100 H až 500 H","cmc":"2,9 %"},{"name":"7 kHz až 8 kHz","range":"100 H až 500 H","cmc":"3,3 %"},{"name":"8 kHz až 9 kHz","range":"100 H až 500 H","cmc":"3,7 %"},{"name":"9 kHz až 10 kHz","range":"100 H až 500 H","cmc":"4,1 %"},{"name":"20 Hz až 35 Hz","range":"500 H až 1 kH","cmc":"0,38 %"},{"name":"35 Hz až 50 Hz","range":"500 H až 1 kH","cmc":"0,40 %"},{"name":"50 Hz až 70 Hz","range":"500 H až 1 kH","cmc":"0,28 %"},{"name":"70 Hz až 100 Hz","range":"500 H až 1 kH","cmc":"0,31 %"},{"name":"100 Hz až 200 Hz","range":"500 H až 1 kH","cmc":"0,31 %"},{"name":"200 Hz až 300 Hz","range":"500 H až 1 kH","cmc":"0,39 %"},{"name":"300 Hz až 400 Hz","range":"500 H až 1 kH","cmc":"0,47 %"},{"name":"400 Hz až 500 Hz","range":"500 H až 1 kH","cmc":"0,55 %"},{"name":"500 Hz až 600 Hz","range":"500 H až 1 kH","cmc":"0,62 %"},{"name":"600 Hz až 700 Hz","range":"500 H až 1 kH","cmc":"0,70 %"},{"name":"700 Hz až 800 Hz","range":"500 H až 1 kH","cmc":"0,78 %"},{"name":"800 Hz až 900 Hz","range":"500 H až 1 kH","cmc":"0,86 %"},{"name":"900 Hz až 1 kHz","range":"500 H až 1 kH","cmc":"0,93 %"}],"technique":"Pomiar bezpośredni miernikiem RLC","technique_en":"Direct measurement by a RLC meter","technique_zh":"用 RLC 表直接测量","technique_cs":"Přímé měření RLC měřidlem","techniques":["Pomiar bezpośredni miernikiem RLC"],"techniques_en":["Direct measurement by a RLC meter"],"techniques_zh":["用 RLC 表直接测量"],"techniques_cs":["Přímé měření RLC měřidlem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 kHz do 15 kHz od 1 µH do 5 µH CMC 2,4 %\n15 kHz do 20 kHz od 1 µH do 5 µH CMC 1,7 %\n20 kHz do 25 kHz od 1 µH do 5 µH CMC 1,3 %\n25 kHz do 30 kHz od 1 µH do 5 µH CMC 1,1 %\n30 kHz do 40 kHz od 1 µH do 5 µH CMC 0,89 %\n40 kHz do 50 kHz od 1 µH do 5 µH CMC 0,71 %\n50 kHz do 60 kHz od 1 µH do 5 µH CMC 0,60 %\n60 kHz do 70 kHz od 1 µH do 5 µH CMC 0,53 %\n70 kHz do 80 kHz od 1 µH do 5 µH CMC 0,47 %\n80 kHz do 90 kHz od 1 µH do 5 µH CMC 0,43 %\n90 kHz do 100 kHz od 1 µH do 5 µH CMC 0,40 %\n100 kHz do 150 kHz od 1 µH do 5 µH CMC 0,56 %\n150 kHz do 200 kHz od 1 µH do 5 µH CMC 0,45 %\n200 kHz do 250 kHz od 1 µH do 5 µH CMC 0,36 %\n250 kHz do 300 kHz od 1 µH do 5 µH CMC 0,32 %\n300 kHz do 400 kHz od 1 µH do 5 µH CMC 0,36 %\n400 kHz do 500 kHz od 1 µH do 5 µH CMC 0,31 %\n500 kHz do 700 kHz od 1 µH do 5 µH CMC 0,28 %\n700 kHz do 1 MHz od 1 µH do 5 µH CMC 0,24 %\n2 kHz do 3 kHz od 5 µH do 10 µH CMC 2,4 %\n3 kHz do 5 kHz od 5 µH do 10 µH CMC 1,7 %\n5 kHz do 7 kHz od 5 µH do 10 µH CMC 1,1 %\n7 kHz do 10 kHz od 5 µH do 10 µH CMC 0,79 %\n10 kHz do 15 kHz od 5 µH do 10 µH CMC 0,60 %\n15 kHz do 20 kHz od 5 µH do 10 µH CMC 0,45 %\n20 kHz do 25 kHz od 5 µH do 10 µH CMC 0,38 %\n25 kHz do 30 kHz od 5 µH do 10 µH CMC 0,34 %\n30 kHz do 40 kHz od 5 µH do 10 µH CMC 0,31 %\n40 kHz do 50 kHz od 5 µH do 10 µH CMC 0,27 %\n50 kHz do 60 kHz od 5 µH do 10 µH CMC 0,25 %\n60 kHz do 100 kHz od 5 µH do 10 µH CMC 0,23 %\n100 kHz do 150 kHz od 5 µH do 10 µH CMC 0,24 %\n150 kHz do 200 kHz od 5 µH do 10 µH CMC 0,22 %\n200 kHz do 500 kHz od 5 µH do 10 µH CMC 0,20 %\n500 kHz do 1 MHz od 5 µH do 10 µH CMC 0,13 %\n1 kHz do 2 kHz od 10 µH do 50 µH CMC 2,4 %\n2 kHz do 3 kHz od 10 µH do 50 µH CMC 1,3 %\n3 kHz do 5 kHz od 10 µH do 50 µH CMC 0,89 %\n5 kHz do 7 kHz od 10 µH do 50 µH CMC 0,60 %\n7 kHz do 10 kHz od 10 µH do 50 µH CMC 0,47 %\n10 kHz do 15 kHz od 10 µH do 50 µH CMC 0,38 %\n15 kHz do 20 kHz od 10 µH do 50 µH CMC 0,31 %\n20 kHz do 25 kHz od 10 µH do 50 µH CMC 0,27 %\n25 kHz do 30 kHz od 10 µH do 50 µH CMC 0,25 %\n30 kHz do 50 kHz od 10 µH do 50 µH CMC 0,23 %\n50 kHz do 70 kHz od 10 µH do 50 µH CMC 0,21 %\n70 kHz do 100 kHz od 10 µH do 50 µH CMC 0,19 %\n100 kHz do 250 kHz od 10 µH do 50 µH CMC 0,20 %\n250 kHz do 300 kHz od 10 µH do 50 µH CMC 0,12 %\n300 kHz do 1 MHz od 10 µH do 50 µH CMC 0,13 %\n200 Hz do 300 Hz od 50 µH do 100 µH CMC 2,6 %\n300 Hz do 400 Hz od 50 µH do 100 µH CMC 1,8 %\n400 Hz do 500 Hz od 50 µH do 100 µH CMC 1,3 %\n500 Hz do 600 Hz od 50 µH do 100 µH CMC 1,1 %\n600 Hz do 700 Hz od 50 µH do 100 µH CMC 0,89 %\n700 Hz do 800 Hz od 50 µH do 100 µH CMC 0,79 %\n800 Hz do 900 Hz od 50 µH do 100 µH CMC 0,71 %\n900 Hz do 1 kHz od 50 µH do 100 µH CMC 0,65 %\n1 kHz do 2 kHz od 50 µH do 100 µH CMC 0,60 %\n2 kHz do 3 kHz od 50 µH do 100 µH CMC 0,38 %\n3 kHz do 5 kHz od 50 µH do 100 µH CMC 0,31 %\n5 kHz do 10 kHz od 50 µH do 100 µH CMC 0,25 %\n10 kHz do 15 kHz od 50 µH do 100 µH CMC 0,21 %\n15 kHz do 30 kHz od 50 µH do 100 µH CMC 0,19 %\n30 kHz do 50 kHz od 50 µH do 100 µH CMC 0,18 %\n50 kHz do 100 kHz od 50 µH do 100 µH CMC 0,12 %\n100 kHz do 250 kHz od 50 µH do 100 µH CMC 0,20 %\n250 kHz do 300 kHz od 50 µH do 100 µH CMC 0,12 %\n300 kHz do 1 MHz od 50 µH do 100 µH CMC 0,13 %\n80 Hz do 90 Hz od 100 µH do 500 µH CMC 6,2 %\n90 Hz do 100 Hz od 100 µH do 500 µH CMC 5,4 %\n100 Hz do 200 Hz od 100 µH do 500 µH CMC 2,6 %\n200 Hz do 300 Hz od 100 µH do 500 µH CMC 1,3 %\n300 Hz do 400 Hz od 100 µH do 500 µH CMC 0,89 %\n400 Hz do 500 Hz od 100 µH do 500 µH CMC 0,71 %\n500 Hz do 600 Hz od 100 µH do 500 µH CMC 0,60 %\n600 Hz do 700 Hz od 100 µH do 500 µH CMC 0,53 %\n700 Hz do 800 Hz od 100 µH do 500 µH CMC 0,47 %\n800 Hz do 900 Hz od 100 µH do 500 µH CMC 0,43 %\n900 Hz do 1 kHz od 100 µH do 500 µH CMC 0,40 %\n1 kHz do 2 kHz od 100 µH do 500 µH CMC 0,38 %\n2 kHz do 3 kHz od 100 µH do 500 µH CMC 0,27 %\n3 kHz do 5 kHz od 100 µH do 500 µH CMC 0,23 %\n5 kHz do 10 kHz od 100 µH do 500 µH CMC 0,21 %\n10 kHz do 25 kHz od 100 µH do 500 µH CMC 0,18 %\n25 kHz do 30 kHz od 100 µH do 500 µH CMC 0,12 %\n30 kHz do 100 kHz od 100 µH do 500 µH CMC 0,12 %\n100 kHz do 300 kHz od 100 µH do 500 µH CMC 0,11 %\n300 kHz do 1 MHz od 100 µH do 500 µH CMC 0,17 %\n50 Hz do 60 Hz od 500 µH do 1 mH CMC 2,3 %\n60 Hz do 70 Hz od 500 µH do 1 mH CMC 1,9 %\n70 Hz do 80 Hz od 500 µH do 1 mH CMC 1,6 %\n80 Hz do 100 Hz od 500 µH do 1 mH CMC 1,4 %\n100 Hz do 200 Hz od 500 µH do 1 mH CMC 0,60 %\n200 Hz do 300 Hz od 500 µH do 1 mH CMC 0,38 %\n300 Hz do 400 Hz od 500 µH do 1 mH CMC 0,31 %\n400 Hz do 500 Hz od 500 µH do 1 mH CMC 0,27 %\n500 Hz do 600 Hz od 500 µH do 1 mH CMC 0,25 %\n600 Hz do 900 Hz od 500 µH do 1 mH CMC 0,23 %\n900 Hz do 1 kHz od 500 µH do 1 mH CMC 0,21 %\n1 kHz do 2 kHz od 500 µH do 1 mH CMC 0,38 %\n2 kHz do 3 kHz od 500 µH do 1 mH CMC 0,27 %\n3 kHz do 5 kHz od 500 µH do 1 mH CMC 0,23 %\n5 kHz do 10 kHz od 500 µH do 1 mH CMC 0,21 %\n10 kHz do 25 kHz od 500 µH do 1 mH CMC 0,18 %\n25 kHz do 100 kHz od 500 µH do 1 mH CMC 0,12 %\n100 kHz do 300 kHz od 500 µH do 1 mH CMC 0,11 %\n300 kHz do 1 MHz od 500 µH do 1 mH CMC 0,17 %\n20 Hz do 30 Hz od 1 mH do 5 mH CMC 3,9 %\n30 Hz do 40 Hz od 1 mH do 5 mH CMC 2,5 %\n40 Hz do 50 Hz od 1 mH do 5 mH CMC 1,8 %\n50 Hz do 60 Hz od 1 mH do 5 mH CMC 1,3 %\n60 Hz do 80 Hz od 1 mH do 5 mH CMC 1,0 %\n80 Hz do 90 Hz od 1 mH do 5 mH CMC 0,74 %\n90 Hz do 100 Hz od 1 mH do 5 mH CMC 0,66 %\n100 Hz do 200 Hz od 1 mH do 5 mH CMC 0,38 %\n200 Hz do 300 Hz od 1 mH do 5 mH CMC 0,27 %\n300 Hz do 500 Hz od 1 mH do 5 mH CMC 0,23 %\n500 Hz do 700 Hz od 1 mH do 5 mH CMC 0,21 %\n700 Hz do 1 kHz od 1 mH do 5 mH CMC 0,19 %\n1 kHz do 3 kHz od 1 mH do 5 mH CMC 0,18 %\n3 kHz do 100 kHz od 1 mH do 5 mH CMC 0,12 %\n100 kHz do 300 kHz od 1 mH do 5 mH CMC 0,17 %\n300 kHz do 600 kHz od 1 mH do 5 mH CMC 0,21 %\n600 kHz do 1 MHz od 1 mH do 5 mH CMC 0,24 %\n20 Hz do 30 Hz od 5 mH do 10 mH CMC 1,1 %\n30 Hz do 40 Hz od 5 mH do 10 mH CMC 0,75 %\n40 Hz do 50 Hz od 5 mH do 10 mH CMC 0,61 %\n50 Hz do 60 Hz od 5 mH do 10 mH CMC 0,37 %\n60 Hz do 70 Hz od 5 mH do 10 mH CMC 0,33 %\n70 Hz do 80 Hz od 5 mH do 10 mH CMC 0,30 %\n80 Hz do 90 Hz od 5 mH do 10 mH CMC 0,28 %\n90 Hz do 100 Hz od 5 mH do 10 mH CMC 0,26 %\n100 Hz do 200 Hz od 5 mH do 10 mH CMC 0,38 %\n200 Hz do 300 Hz od 5 mH do 10 mH CMC 0,27 %\n300 Hz do 500 Hz od 5 mH do 10 mH CMC 0,23 %\n500 Hz do 700 Hz od 5 mH do 10 mH CMC 0,21 %\n700 Hz do 1 kHz od 5 mH do 10 mH CMC 0,19 %\n1 kHz do 3 kHz od 5 mH do 10 mH CMC 0,18 %\n3 kHz do 100 kHz od 5 mH do 10 mH CMC 0,12 %\n100 kHz do 300 kHz od 5 mH do 10 mH CMC 0,17 %\n300 kHz do 600 kHz od 5 mH do 10 mH CMC 0,21 %\n600 kHz do 1 MHz od 5 mH do 10 mH CMC 0,24 %\n20 Hz do 30 Hz od 10 mH do 50 mH CMC 0,69 %\n30 Hz do 40 Hz od 10 mH do 50 mH CMC 0,54 %\n40 Hz do 50 Hz od 10 mH do 50 mH CMC 0,47 %\n50 Hz do 60 Hz od 10 mH do 50 mH CMC 0,27 %\n60 Hz do 80 Hz od 10 mH do 50 mH CMC 0,24 %\n80 Hz do 100 Hz od 10 mH do 50 mH CMC 0,22 %\n100 Hz do 250 Hz od 10 mH do 50 mH CMC 0,18 %\n250 Hz do 1 kHz od 10 mH do 50 mH CMC 0,12 %\n1 kHz do 30 kHz od 10 mH do 50 mH CMC 0,11 %\n30 kHz do 100 kHz od 10 mH do 50 mH CMC 0,17 %\n100 kHz do 200 kHz od 10 mH do 50 mH CMC 0,21 %\n200 kHz do 300 kHz od 10 mH do 50 mH CMC 0,23 %\n300 kHz do 400 kHz od 10 mH do 50 mH CMC 0,31 %\n400 kHz do 500 kHz od 10 mH do 50 mH CMC 0,35 %\n500 kHz do 700 kHz od 10 mH do 50 mH CMC 0,43 %\n700 kHz do 1 MHz od 10 mH do 50 mH CMC 0,55 %\n20 Hz do 30 Hz od 50 mH do 100 mH CMC 0,40 %\n30 Hz do 50 Hz od 50 mH do 100 mH CMC 0,37 %\n50 Hz do 60 Hz od 50 mH do 100 mH CMC 0,27 %\n60 Hz do 80 Hz od 50 mH do 100 mH CMC 0,24 %\n80 Hz do 100 Hz od 50 mH do 100 mH CMC 0,22 %\n100 Hz do 250 Hz od 50 mH do 100 mH CMC 0,18 %\n250 Hz do 1 kHz od 50 mH do 100 mH CMC 0,12 %\n1 kHz do 30 kHz od 50 mH do 100 mH CMC 0,11 %\n30 kHz do 100 kHz od 50 mH do 100 mH CMC 0,17 %\n100 kHz do 200 kHz od 50 mH do 100 mH CMC 0,21 %\n200 kHz do 300 kHz od 50 mH do 100 mH CMC 0,23 %\n300 kHz do 400 kHz od 50 mH do 100 mH CMC 0,47 %\n400 kHz do 500 kHz od 50 mH do 100 mH CMC 0,55 %\n500 kHz do 600 kHz od 50 mH do 100 mH CMC 0,62 %\n600 kHz do 700 kHz od 50 mH do 100 mH CMC 0,70 %\n700 kHz do 800 kHz od 50 mH do 100 mH CMC 0,78 %\n800 kHz do 1 MHz od 50 mH do 100 mH CMC 0,93 %\n20 Hz do 30 Hz od 100 mH do 500 mH CMC 0,27 %\n30 Hz do 50 Hz od 100 mH do 500 mH CMC 0,35 %\n50 Hz do 100 Hz od 100 mH do 500 mH CMC 0,18 %\n100 Hz do 1 kHz od 100 mH do 500 mH CMC 0,12 %\n1 kHz do 30 kHz od 100 mH do 500 mH CMC 0,13 %\n30 kHz do 60 kHz od 100 mH do 500 mH CMC 0,21 %\n60 kHz do 100 kHz od 100 mH do 500 mH CMC 0,24 %\n100 kHz do 150 kHz od 100 mH do 500 mH CMC 0,33 %\n150 kHz do 200 kHz od 100 mH do 500 mH CMC 0,39 %\n200 kHz do 250 kHz od 100 mH do 500 mH CMC 0,45 %\n250 kHz do 300 kHz od 100 mH do 500 mH CMC 0,51 %\n300 kHz do 400 kHz od 100 mH do 500 mH CMC 1,8 %\n400 kHz do 500 kHz od 100 mH do 500 mH CMC 2,1 %\n500 kHz do 600 kHz od 100 mH do 500 mH CMC 2,5 %\n600 kHz do 700 kHz od 100 mH do 500 mH CMC 2,9 %\n700 kHz do 800 kHz od 100 mH do 500 mH CMC 3,3 %\n800 kHz do 900 kHz od 100 mH do 500 mH CMC 3,7 %\n900 kHz do 1 MHz od 100 mH do 500 mH CMC 4,1 %\n20 Hz do 30 Hz od 500 mH do 1 H CMC 0,27 %\n30 Hz do 50 Hz od 500 mH do 1 H CMC 0,35 %\n50 Hz do 100 Hz od 500 mH do 1 H CMC 0,18 %\n100 Hz do 1 kHz od 500 mH do 1 H CMC 0,12 %\n1 kHz do 30 kHz od 500 mH do 1 H CMC 0,13 %\n30 kHz do 60 kHz od 500 mH do 1 H CMC 0,21 %\n60 kHz do 100 kHz od 500 mH do 1 H CMC 0,24 %\n100 kHz do 150 kHz od 500 mH do 1 H CMC 0,51 %\n150 kHz do 200 kHz od 500 mH do 1 H CMC 0,62 %\n200 kHz do 250 kHz od 500 mH do 1 H CMC 0,74 %\n250 kHz do 300 kHz od 500 mH do 1 H CMC 0,86 %\n300 kHz do 400 kHz od 500 mH do 1 H CMC 3,3 %\n400 kHz do 500 kHz od 500 mH do 1 H CMC 4,1 %\n500 kHz do 600 kHz od 500 mH do 1 H CMC 4,9 %\n600 kHz do 700 kHz od 500 mH do 1 H CMC 5,6 %\n700 kHz do 800 kHz od 500 mH do 1 H CMC 6,4 %\n800 kHz do 900 kHz od 500 mH do 1 H CMC 7,2 %\n900 kHz do 1 MHz od 500 mH do 1 H CMC 8,0 %\n20 Hz do 50 Hz od 1 H do 2 H CMC 0,34 %\n50 Hz do 100 Hz od 1 H do 2 H CMC 0,18 %\n100 Hz do 1 kHz od 1 H do 2 H CMC 0,12 %\n1 kHz do 5 kHz od 1 H do 2 H CMC 0,15 %\n5 kHz do 10 kHz od 1 H do 2 H CMC 0,24 %\n10 kHz do 15 kHz od 1 H do 2 H CMC 0,28 %\n15 kHz do 20 kHz od 1 H do 2 H CMC 0,31 %\n20 kHz do 25 kHz od 1 H do 2 H CMC 0,35 %\n25 kHz do 30 kHz od 1 H do 2 H CMC 0,38 %\n30 kHz do 50 kHz od 1 H do 2 H CMC 0,35 %\n50 kHz do 70 kHz od 1 H do 2 H CMC 0,43 %\n70 kHz do 100 kHz od 1 H do 2 H CMC 0,55 %\n100 kHz do 150 kHz od 1 H do 2 H CMC 1,9 %\n150 kHz do 200 kHz od 1 H do 2 H CMC 2,5 %\n200 kHz do 250 kHz od 1 H do 2 H CMC 3,1 %\n250 kHz do 300 kHz od 1 H do 2 H CMC 3,7 %\n300 kHz do 400 kHz od 1 H do 2 H CMC 6,4 %\n400 kHz do 500 kHz od 1 H do 2 H CMC 8,0 %\n20 Hz do 50 Hz od 2 H do 5 H CMC 0,34 %\n50 Hz do 100 Hz od 2 H do 5 H CMC 0,18 %\n100 Hz do 1 kHz od 2 H do 5 H CMC 0,12 %\n1 kHz do 5 kHz od 2 H do 5 H CMC 0,15 %\n5 kHz do 10 kHz od 2 H do 5 H CMC 0,24 %\n10 kHz do 15 kHz od 2 H do 5 H CMC 0,28 %\n15 kHz do 20 kHz od 2 H do 5 H CMC 0,31 %\n20 kHz do 25 kHz od 2 H do 5 H CMC 0,35 %\n25 kHz do 30 kHz od 2 H do 5 H CMC 0,38 %\n30 kHz do 50 kHz od 2 H do 5 H CMC 0,35 %\n50 kHz do 70 kHz od 2 H do 5 H CMC 0,43 %\n70 kHz do 100 kHz od 2 H do 5 H CMC 0,55 %\n100 kHz do 150 kHz od 2 H do 5 H CMC 1,9 %\n150 kHz do 200 kHz od 2 H do 5 H CMC 2,5 %\n200 kHz do 250 kHz od 2 H do 5 H CMC 3,1 %\n250 kHz do 300 kHz od 2 H do 5 H CMC 3,7 %\n50 Hz do 100 Hz od 5 H do 10 H CMC 0,18 %\n100 Hz do 1 kHz od 5 H do 10 H CMC 0,12 %\n1 kHz do 5 kHz od 5 H do 10 H CMC 0,15 %\n5 kHz do 10 kHz od 5 H do 10 H CMC 0,24 %\n10 kHz do 15 kHz od 5 H do 10 H CMC 0,28 %\n15 kHz do 20 kHz od 5 H do 10 H CMC 0,31 %\n20 kHz do 25 kHz od 5 H do 10 H CMC 0,35 %\n25 kHz do 30 kHz od 5 H do 10 H CMC 0,38 %\n30 kHz do 40 kHz od 5 H do 10 H CMC 0,47 %\n40 kHz do 50 kHz od 5 H do 10 H CMC 0,55 %\n50 kHz do 60 kHz od 5 H do 10 H CMC 0,62 %\n60 kHz do 70 kHz od 5 H do 10 H CMC 0,70 %\n70 kHz do 80 kHz od 5 H do 10 H CMC 0,78 %\n80 kHz do 90 kHz od 5 H do 10 H CMC 0,86 %\n90 kHz do 100 kHz od 5 H do 10 H CMC 0,93 %\n100 kHz do 150 kHz od 5 H do 10 H CMC 3,7 %\n150 kHz do 200 kHz od 5 H do 10 H CMC 4,9 %\n200 kHz do 250 kHz od 5 H do 10 H CMC 6,0 %\n250 kHz do 300 kHz od 5 H do 10 H CMC 7,2 %\n50 Hz do 100 Hz od 10 H do 50 H CMC 0,18 %\n100 Hz do 500 Hz od 10 H do 50 H CMC 0,15 %\n500 Hz do 800 Hz od 10 H do 50 H CMC 0,22 %\n800 Hz do 2 kHz od 10 H do 50 H CMC 0,24 %\n2 kHz do 3 kHz od 10 H do 50 H CMC 0,28 %\n3 kHz do 5 kHz od 10 H do 50 H CMC 0,35 %\n5 kHz do 7 kHz od 10 H do 50 H CMC 0,43 %\n7 kHz do 10 kHz od 10 H do 50 H CMC 0,55 %\n10 kHz do 15 kHz od 10 H do 50 H CMC 0,74 %\n15 kHz do 20 kHz od 10 H do 50 H CMC 0,93 %\n20 kHz do 25 kHz od 10 H do 50 H CMC 1,2 %\n25 kHz do 30 kHz od 10 H do 50 H CMC 1,4 %\n30 kHz do 40 kHz od 10 H do 50 H CMC 1,8 %\n40 kHz do 50 kHz od 10 H do 50 H CMC 2,1 %\n50 kHz do 60 kHz od 10 H do 50 H CMC 2,5 %\n60 kHz do 70 kHz od 10 H do 50 H CMC 2,9 %\n70 kHz do 80 kHz od 10 H do 50 H CMC 3,3 %\n80 kHz do 90 kHz od 10 H do 50 H CMC 3,7 %\n90 kHz do 100 kHz od 10 H do 50 H CMC 4,1 %\n50 Hz do 100 Hz od 50 H do 100 H CMC 0,18 %\n100 Hz do 500 Hz od 50 H do 100 H CMC 0,15 %\n500 Hz do 800 Hz od 50 H do 100 H CMC 0,22 %\n800 Hz do 1 kHz od 50 H do 100 H CMC 0,24 %\n1 kHz do 2 kHz od 50 H do 100 H CMC 0,31 %\n2 kHz do 3 kHz od 50 H do 100 H CMC 0,39 %\n3 kHz do 5 kHz od 50 H do 100 H CMC 0,55 %\n5 kHz do 7 kHz od 50 H do 100 H CMC 0,70 %\n7 kHz do 10 kHz od 50 H do 100 H CMC 0,93 %\n10 kHz do 15 kHz od 50 H do 100 H CMC 1,4 %\n15 kHz do 20 kHz od 50 H do 100 H CMC 1,8 %\n20 kHz do 25 kHz od 50 H do 100 H CMC 2,1 %\n25 kHz do 30 kHz od 50 H do 100 H CMC 2,5 %\n20 Hz do 35 Hz od 100 H do 500 H CMC 0,38 %\n35 Hz do 50 Hz od 100 H do 500 H CMC 0,40 %\n50 Hz do 70 Hz od 100 H do 500 H CMC 0,28 %\n70 Hz do 200 Hz od 100 H do 500 H CMC 0,31 %\n200 Hz do 300 Hz od 100 H do 500 H CMC 0,39 %\n300 Hz do 400 Hz od 100 H do 500 H CMC 0,47 %\n400 Hz do 500 Hz od 100 H do 500 H CMC 0,55 %\n500 Hz do 600 Hz od 100 H do 500 H CMC 0,62 %\n600 Hz do 700 Hz od 100 H do 500 H CMC 0,70 %\n700 Hz do 800 Hz od 100 H do 500 H CMC 0,78 %\n800 Hz do 900 Hz od 100 H do 500 H CMC 0,86 %\n900 Hz do 2 kHz od 100 H do 500 H CMC 0,93 %\n2 kHz do 3 kHz od 100 H do 500 H CMC 1,4 %\n3 kHz do 5 kHz od 100 H do 500 H CMC 2,1 %\n5 kHz do 7 kHz od 100 H do 500 H CMC 2,9 %\n7 kHz do 8 kHz od 100 H do 500 H CMC 3,3 %\n8 kHz do 9 kHz od 100 H do 500 H CMC 3,7 %\n9 kHz do 10 kHz od 100 H do 500 H CMC 4,1 %\n20 Hz do 35 Hz od 500 H do 1 kH CMC 0,38 %\n35 Hz do 50 Hz od 500 H do 1 kH CMC 0,40 %\n50 Hz do 70 Hz od 500 H do 1 kH CMC 0,28 %\n70 Hz do 100 Hz od 500 H do 1 kH CMC 0,31 %\n100 Hz do 200 Hz od 500 H do 1 kH CMC 0,31 %\n200 Hz do 300 Hz od 500 H do 1 kH CMC 0,39 %\n300 Hz do 400 Hz od 500 H do 1 kH CMC 0,47 %\n400 Hz do 500 Hz od 500 H do 1 kH CMC 0,55 %\n500 Hz do 600 Hz od 500 H do 1 kH CMC 0,62 %\n600 Hz do 700 Hz od 500 H do 1 kH CMC 0,70 %\n700 Hz do 800 Hz od 500 H do 1 kH CMC 0,78 %\n800 Hz do 900 Hz od 500 H do 1 kH CMC 0,86 %\n900 Hz do 1 kHz od 500 H do 1 kH CMC 0,93 %\nPomiar bezpośredni miernikiem RLC","reference":"TP8, TP24","norm_bases":["TP8","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indukcyjność / Wzorce indukcyjności Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem RLC 10 kHz do 15 kHz od 1 µH do 5 µH CMC 2,4 % 15 kHz do 20 kHz od 1 µH do 5 µH CMC 1,7 % 20 kHz do 25 kHz od 1 µH do 5 µH CMC 1,3 % 25 kHz do 30 kHz od 1 µH do 5 µH CMC 1,1 % 30 kHz do 40 kHz od 1 µH do 5 µH CMC 0,89 % 40 kHz do 50 kHz od 1 µH do 5 µH CMC 0,71 % 50 kHz do 60 kHz od 1 µH do 5 µH CMC 0,60 % 60 kHz do 70 kHz od 1 µH do 5 µH CMC 0,53 % 70 kHz do 80 kHz od 1 µH do 5 µH CMC 0,47 % 80 kHz do 90 kHz od 1 µH do 5 µH CMC 0,43 % 90 kHz do 100 kHz od 1 µH do 5 µH CMC 0,40 % 100 kHz do 150 kHz od 1 µH do 5 µH CMC 0,56 % 150 kHz do 200 kHz od 1 µH do 5 µH CMC 0,45 % 200 kHz do 250 kHz od 1 µH do 5 µH CMC 0,36 % 250 kHz do 300 kHz od 1 µH do 5 µH CMC 0,32 % 300 kHz do 400 kHz od 1 µH do 5 µH CMC 0,36 % 400 kHz do 500 kHz od 1 µH do 5 µH CMC 0,31 % 500 kHz do 700 kHz od 1 µH do 5 µH CMC 0,28 % 700 kHz do 1 MHz od 1 µH do 5 µH CMC 0,24 % 2 kHz do 3 kHz od 5 µH do 10 µH CMC 2,4 % 3 kHz do 5 kHz od 5 µH do 10 µH CMC 1,7 % 5 kHz do 7 kHz od 5 µH do 10 µH CMC 1,1 % 7 kHz do 10 kHz od 5 µH do 10 µH CMC 0,79 % 10 kHz do 15 kHz od 5 µH do 10 µH CMC 0,60 % 15 kHz do 20 kHz od 5 µH do 10 µH CMC 0,45 % 20 kHz do 25 kHz od 5 µH do 10 µH CMC 0,38 % 25 kHz do 30 kHz od 5 µH do 10 µH CMC 0,34 % 30 kHz do 40 kHz od 5 µH do 10 µH CMC 0,31 % 40 kHz do 50 kHz od 5 µH do 10 µH CMC 0,27 % 50 kHz do 60 kHz od 5 µH do 10 µH CMC 0,25 % 60 kHz do 100 kHz od 5 µH do 10 µH CMC 0,23 % 100 kHz do 150 kHz od 5 µH do 10 µH CMC 0,24 % 150 kHz do 200 kHz od 5 µH do 10 µH CMC 0,22 % 200 kHz do 500 kHz od 5 µH do 10 µH CMC 0,20 % 500 kHz do 1 MHz od 5 µH do 10 µH CMC 0,13 % 1 kHz do 2 kHz od 10 µH do 50 µH CMC 2,4 % 2 kHz do 3 kHz od 10 µH do 50 µH CMC 1,3 % 3 kHz do 5 kHz od 10 µH do 50 µH CMC 0,89 % 5 kHz do 7 kHz od 10 µH do 50 µH CMC 0,60 % 7 kHz do 10 kHz od 10 µH do 50 µH CMC 0,47 % 10 kHz do 15 kHz od 10 µH do 50 µH CMC 0,38 % 15 kHz do 20 kHz od 10 µH do 50 µH CMC 0,31 % 20 kHz do 25 kHz od 10 µH do 50 µH CMC 0,27 % 25 kHz do 30 kHz od 10 µH do 50 µH CMC 0,25 % 30 kHz do 50 kHz od 10 µH do 50 µH CMC 0,23 % 50 kHz do 70 kHz od 10 µH do 50 µH CMC 0,21 % 70 kHz do 100 kHz od 10 µH do 50 µH CMC 0,19 % 100 kHz do 250 kHz od 10 µH do 50 µH CMC 0,20 % 250 kHz do 300 kHz od 10 µH do 50 µH CMC 0,12 % 300 kHz do 1 MHz od 10 µH do 50 µH CMC 0,13 % 200 Hz do 300 Hz od 50 µH do 100 µH CMC 2,6 % 300 Hz do 400 Hz od 50 µH do 100 µH CMC 1,8 % 400 Hz do 500 Hz od 50 µH do 100 µH CMC 1,3 % 500 Hz do 600 Hz od 50 µH do 100 µH CMC 1,1 % 600 Hz do 700 Hz od 50 µH do 100 µH CMC 0,89 % 700 Hz do 800 Hz od 50 µH do 100 µH CMC 0,79 % 800 Hz do 900 Hz od 50 µH do 100 µH CMC 0,71 % 900 Hz do 1 kHz od 50 µH do 100 µH CMC 0,65 % 1 kHz do 2 kHz od 50 µH do 100 µH CMC 0,60 % 2 kHz do 3 kHz od 50 µH do 100 µH CMC 0,38 % 3 kHz do 5 kHz od 50 µH do 100 µH CMC 0,31 % 5 kHz do 10 kHz od 50 µH do 100 µH CMC 0,25 % 10 kHz do 15 kHz od 50 µH do 100 µH CMC 0,21 % 15 kHz do 30 kHz od 50 µH do 100 µH CMC 0,19 % 30 kHz do 50 kHz od 50 µH do 100 µH CMC 0,18 % 50 kHz do 100 kHz od 50 µH do 100 µH CMC 0,12 % 100 kHz do 250 kHz od 50 µH do 100 µH CMC 0,20 % 250 kHz do 300 kHz od 50 µH do 100 µH CMC 0,12 % 300 kHz do 1 MHz od 50 µH do 100 µH CMC 0,13 % 80 Hz do 90 Hz od 100 µH do 500 µH CMC 6,2 % 90 Hz do 100 Hz od 100 µH do 500 µH CMC 5,4 % 100 Hz do 200 Hz od 100 µH do 500 µH CMC 2,6 % 200 Hz do 300 Hz od 100 µH do 500 µH CMC 1,3 % 300 Hz do 400 Hz od 100 µH do 500 µH CMC 0,89 % 400 Hz do 500 Hz od 100 µH do 500 µH CMC 0,71 % 500 Hz do 600 Hz od 100 µH do 500 µH CMC 0,60 % 600 Hz do 700 Hz od 100 µH do 500 µH CMC 0,53 % 700 Hz do 800 Hz od 100 µH do 500 µH CMC 0,47 % 800 Hz do 900 Hz od 100 µH do 500 µH CMC 0,43 % 900 Hz do 1 kHz od 100 µH do 500 µH CMC 0,40 % 1 kHz do 2 kHz od 100 µH do 500 µH CMC 0,38 % 2 kHz do 3 kHz od 100 µH do 500 µH CMC 0,27 % 3 kHz do 5 kHz od 100 µH do 500 µH CMC 0,23 % 5 kHz do 10 kHz od 100 µH do 500 µH CMC 0,21 % 10 kHz do 25 kHz od 100 µH do 500 µH CMC 0,18 % 25 kHz do 30 kHz od 100 µH do 500 µH CMC 0,12 % 30 kHz do 100 kHz od 100 µH do 500 µH CMC 0,12 % 100 kHz do 300 kHz od 100 µH do 500 µH CMC 0,11 % 300 kHz do 1 MHz od 100 µH do 500 µH CMC 0,17 % 50 Hz do 60 Hz od 500 µH do 1 mH CMC 2,3 % 60 Hz do 70 Hz od 500 µH do 1 mH CMC 1,9 % 70 Hz do 80 Hz od 500 µH do 1 mH CMC 1,6 % 80 Hz do 100 Hz od 500 µH do 1 mH CMC 1,4 % 100 Hz do 200 Hz od 500 µH do 1 mH CMC 0,60 % 200 Hz do 300 Hz od 500 µH do 1 mH CMC 0,38 % 300 Hz do 400 Hz od 500 µH do 1 mH CMC 0,31 % 400 Hz do 500 Hz od 500 µH do 1 mH CMC 0,27 % 500 Hz do 600 Hz od 500 µH do 1 mH CMC 0,25 % 600 Hz do 900 Hz od 500 µH do 1 mH CMC 0,23 % 900 Hz do 1 kHz od 500 µH do 1 mH CMC 0,21 % 1 kHz do 2 kHz od 500 µH do 1 mH CMC 0,38 % 2 kHz do 3 kHz od 500 µH do 1 mH CMC 0,27 % 3 kHz do 5 kHz od 500 µH do 1 mH CMC 0,23 % 5 kHz do 10 kHz od 500 µH do 1 mH CMC 0,21 % 10 kHz do 25 kHz od 500 µH do 1 mH CMC 0,18 % 25 kHz do 100 kHz od 500 µH do 1 mH CMC 0,12 % 100 kHz do 300 kHz od 500 µH do 1 mH CMC 0,11 % 300 kHz do 1 MHz od 500 µH do 1 mH CMC 0,17 % 20 Hz do 30 Hz od 1 mH do 5 mH CMC 3,9 % 30 Hz do 40 Hz od 1 mH do 5 mH CMC 2,5 % 40 Hz do 50 Hz od 1 mH do 5 mH CMC 1,8 % 50 Hz do 60 Hz od 1 mH do 5 mH CMC 1,3 % 60 Hz do 80 Hz od 1 mH do 5 mH CMC 1,0 % 80 Hz do 90 Hz od 1 mH do 5 mH CMC 0,74 % 90 Hz do 100 Hz od 1 mH do 5 mH CMC 0,66 % 100 Hz do 200 Hz od 1 mH do 5 mH CMC 0,38 % 200 Hz do 300 Hz od 1 mH do 5 mH CMC 0,27 % 300 Hz do 500 Hz od 1 mH do 5 mH CMC 0,23 % 500 Hz do 700 Hz od 1 mH do 5 mH CMC 0,21 % 700 Hz do 1 kHz od 1 mH do 5 mH CMC 0,19 % 1 kHz do 3 kHz od 1 mH do 5 mH CMC 0,18 % 3 kHz do 100 kHz od 1 mH do 5 mH CMC 0,12 % 100 kHz do 300 kHz od 1 mH do 5 mH CMC 0,17 % 300 kHz do 600 kHz od 1 mH do 5 mH CMC 0,21 % 600 kHz do 1 MHz od 1 mH do 5 mH CMC 0,24 % 20 Hz do 30 Hz od 5 mH do 10 mH CMC 1,1 % 30 Hz do 40 Hz od 5 mH do 10 mH CMC 0,75 % 40 Hz do 50 Hz od 5 mH do 10 mH CMC 0,61 % 50 Hz do 60 Hz od 5 mH do 10 mH CMC 0,37 % 60 Hz do 70 Hz od 5 mH do 10 mH CMC 0,33 % 70 Hz do 80 Hz od 5 mH do 10 mH CMC 0,30 % 80 Hz do 90 Hz od 5 mH do 10 mH CMC 0,28 % 90 Hz do 100 Hz od 5 mH do 10 mH CMC 0,26 % 100 Hz do 200 Hz od 5 mH do 10 mH CMC 0,38 % 200 Hz do 300 Hz od 5 mH do 10 mH CMC 0,27 % 300 Hz do 500 Hz od 5 mH do 10 mH CMC 0,23 % 500 Hz do 700 Hz od 5 mH do 10 mH CMC 0,21 % 700 Hz do 1 kHz od 5 mH do 10 mH CMC 0,19 % 1 kHz do 3 kHz od 5 mH do 10 mH CMC 0,18 % 3 kHz do 100 kHz od 5 mH do 10 mH CMC 0,12 % 100 kHz do 300 kHz od 5 mH do 10 mH CMC 0,17 % 300 kHz do 600 kHz od 5 mH do 10 mH CMC 0,21 % 600 kHz do 1 MHz od 5 mH do 10 mH CMC 0,24 % 20 Hz do 30 Hz od 10 mH do 50 mH CMC 0,69 % 30 Hz do 40 Hz od 10 mH do 50 mH CMC 0,54 % 40 Hz do 50 Hz od 10 mH do 50 mH CMC 0,47 % 50 Hz do 60 Hz od 10 mH do 50 mH CMC 0,27 % 60 Hz do 80 Hz od 10 mH do 50 mH CMC 0,24 % 80 Hz do 100 Hz od 10 mH do 50 mH CMC 0,22 % 100 Hz do 250 Hz od 10 mH do 50 mH CMC 0,18 % 250 Hz do 1 kHz od 10 mH do 50 mH CMC 0,12 % 1 kHz do 30 kHz od 10 mH do 50 mH CMC 0,11 % 30 kHz do 100 kHz od 10 mH do 50 mH CMC 0,17 % 100 kHz do 200 kHz od 10 mH do 50 mH CMC 0,21 % 200 kHz do 300 kHz od 10 mH do 50 mH CMC 0,23 % 300 kHz do 400 kHz od 10 mH do 50 mH CMC 0,31 % 400 kHz do 500 kHz od 10 mH do 50 mH CMC 0,35 % 500 kHz do 700 kHz od 10 mH do 50 mH CMC 0,43 % 700 kHz do 1 MHz od 10 mH do 50 mH CMC 0,55 % 20 Hz do 30 Hz od 50 mH do 100 mH CMC 0,40 % 30 Hz do 50 Hz od 50 mH do 100 mH CMC 0,37 % 50 Hz do 60 Hz od 50 mH do 100 mH CMC 0,27 % 60 Hz do 80 Hz od 50 mH do 100 mH CMC 0,24 % 80 Hz do 100 Hz od 50 mH do 100 mH CMC 0,22 % 100 Hz do 250 Hz od 50 mH do 100 mH CMC 0,18 % 250 Hz do 1 kHz od 50 mH do 100 mH CMC 0,12 % 1 kHz do 30 kHz od 50 mH do 100 mH CMC 0,11 % 30 kHz do 100 kHz od 50 mH do 100 mH CMC 0,17 % 100 kHz do 200 kHz od 50 mH do 100 mH CMC 0,21 % 200 kHz do 300 kHz od 50 mH do 100 mH CMC 0,23 % 300 kHz do 400 kHz od 50 mH do 100 mH CMC 0,47 % 400 kHz do 500 kHz od 50 mH do 100 mH CMC 0,55 % 500 kHz do 600 kHz od 50 mH do 100 mH CMC 0,62 % 600 kHz do 700 kHz od 50 mH do 100 mH CMC 0,70 % 700 kHz do 800 kHz od 50 mH do 100 mH CMC 0,78 % 800 kHz do 1 MHz od 50 mH do 100 mH CMC 0,93 % 20 Hz do 30 Hz od 100 mH do 500 mH CMC 0,27 % 30 Hz do 50 Hz od 100 mH do 500 mH CMC 0,35 % 50 Hz do 100 Hz od 100 mH do 500 mH CMC 0,18 % 100 Hz do 1 kHz od 100 mH do 500 mH CMC 0,12 % 1 kHz do 30 kHz od 100 mH do 500 mH CMC 0,13 % 30 kHz do 60 kHz od 100 mH do 500 mH CMC 0,21 % 60 kHz do 100 kHz od 100 mH do 500 mH CMC 0,24 % 100 kHz do 150 kHz od 100 mH do 500 mH CMC 0,33 % 150 kHz do 200 kHz od 100 mH do 500 mH CMC 0,39 % 200 kHz do 250 kHz od 100 mH do 500 mH CMC 0,45 % 250 kHz do 300 kHz od 100 mH do 500 mH CMC 0,51 % 300 kHz do 400 kHz od 100 mH do 500 mH CMC 1,8 % 400 kHz do 500 kHz od 100 mH do 500 mH CMC 2,1 % 500 kHz do 600 kHz od 100 mH do 500 mH CMC 2,5 % 600 kHz do 700 kHz od 100 mH do 500 mH CMC 2,9 % 700 kHz do 800 kHz od 100 mH do 500 mH CMC 3,3 % 800 kHz do 900 kHz od 100 mH do 500 mH CMC 3,7 % 900 kHz do 1 MHz od 100 mH do 500 mH CMC 4,1 % 20 Hz do 30 Hz od 500 mH do 1 H CMC 0,27 % 30 Hz do 50 Hz od 500 mH do 1 H CMC 0,35 % 50 Hz do 100 Hz od 500 mH do 1 H CMC 0,18 % 100 Hz do 1 kHz od 500 mH do 1 H CMC 0,12 % 1 kHz do 30 kHz od 500 mH do 1 H CMC 0,13 % 30 kHz do 60 kHz od 500 mH do 1 H CMC 0,21 % 60 kHz do 100 kHz od 500 mH do 1 H CMC 0,24 % 100 kHz do 150 kHz od 500 mH do 1 H CMC 0,51 % 150 kHz do 200 kHz od 500 mH do 1 H CMC 0,62 % 200 kHz do 250 kHz od 500 mH do 1 H CMC 0,74 % 250 kHz do 300 kHz od 500 mH do 1 H CMC 0,86 % 300 kHz do 400 kHz od 500 mH do 1 H CMC 3,3 % 400 kHz do 500 kHz od 500 mH do 1 H CMC 4,1 % 500 kHz do 600 kHz od 500 mH do 1 H CMC 4,9 % 600 kHz do 700 kHz od 500 mH do 1 H CMC 5,6 % 700 kHz do 800 kHz od 500 mH do 1 H CMC 6,4 % 800 kHz do 900 kHz od 500 mH do 1 H CMC 7,2 % 900 kHz do 1 MHz od 500 mH do 1 H CMC 8,0 % 20 Hz do 50 Hz od 1 H do 2 H CMC 0,34 % 50 Hz do 100 Hz od 1 H do 2 H CMC 0,18 % 100 Hz do 1 kHz od 1 H do 2 H CMC 0,12 % 1 kHz do 5 kHz od 1 H do 2 H CMC 0,15 % 5 kHz do 10 kHz od 1 H do 2 H CMC 0,24 % 10 kHz do 15 kHz od 1 H do 2 H CMC 0,28 % 15 kHz do 20 kHz od 1 H do 2 H CMC 0,31 % 20 kHz do 25 kHz od 1 H do 2 H CMC 0,35 % 25 kHz do 30 kHz od 1 H do 2 H CMC 0,38 % 30 kHz do 50 kHz od 1 H do 2 H CMC 0,35 % 50 kHz do 70 kHz od 1 H do 2 H CMC 0,43 % 70 kHz do 100 kHz od 1 H do 2 H CMC 0,55 % 100 kHz do 150 kHz od 1 H do 2 H CMC 1,9 % 150 kHz do 200 kHz od 1 H do 2 H CMC 2,5 % 200 kHz do 250 kHz od 1 H do 2 H CMC 3,1 % 250 kHz do 300 kHz od 1 H do 2 H CMC 3,7 % 300 kHz do 400 kHz od 1 H do 2 H CMC 6,4 % 400 kHz do 500 kHz od 1 H do 2 H CMC 8,0 % 20 Hz do 50 Hz od 2 H do 5 H CMC 0,34 % 50 Hz do 100 Hz od 2 H do 5 H CMC 0,18 % 100 Hz do 1 kHz od 2 H do 5 H CMC 0,12 % 1 kHz do 5 kHz od 2 H do 5 H CMC 0,15 % 5 kHz do 10 kHz od 2 H do 5 H CMC 0,24 % 10 kHz do 15 kHz od 2 H do 5 H CMC 0,28 % 15 kHz do 20 kHz od 2 H do 5 H CMC 0,31 % 20 kHz do 25 kHz od 2 H do 5 H CMC 0,35 % 25 kHz do 30 kHz od 2 H do 5 H CMC 0,38 % 30 kHz do 50 kHz od 2 H do 5 H CMC 0,35 % 50 kHz do 70 kHz od 2 H do 5 H CMC 0,43 % 70 kHz do 100 kHz od 2 H do 5 H CMC 0,55 % 100 kHz do 150 kHz od 2 H do 5 H CMC 1,9 % 150 kHz do 200 kHz od 2 H do 5 H CMC 2,5 % 200 kHz do 250 kHz od 2 H do 5 H CMC 3,1 % 250 kHz do 300 kHz od 2 H do 5 H CMC 3,7 % 50 Hz do 100 Hz od 5 H do 10 H CMC 0,18 % 100 Hz do 1 kHz od 5 H do 10 H CMC 0,12 % 1 kHz do 5 kHz od 5 H do 10 H CMC 0,15 % 5 kHz do 10 kHz od 5 H do 10 H CMC 0,24 % 10 kHz do 15 kHz od 5 H do 10 H CMC 0,28 % 15 kHz do 20 kHz od 5 H do 10 H CMC 0,31 % 20 kHz do 25 kHz od 5 H do 10 H CMC 0,35 % 25 kHz do 30 kHz od 5 H do 10 H CMC 0,38 % 30 kHz do 40 kHz od 5 H do 10 H CMC 0,47 % 40 kHz do 50 kHz od 5 H do 10 H CMC 0,55 % 50 kHz do 60 kHz od 5 H do 10 H CMC 0,62 % 60 kHz do 70 kHz od 5 H do 10 H CMC 0,70 % 70 kHz do 80 kHz od 5 H do 10 H CMC 0,78 % 80 kHz do 90 kHz od 5 H do 10 H CMC 0,86 % 90 kHz do 100 kHz od 5 H do 10 H CMC 0,93 % 100 kHz do 150 kHz od 5 H do 10 H CMC 3,7 % 150 kHz do 200 kHz od 5 H do 10 H CMC 4,9 % 200 kHz do 250 kHz od 5 H do 10 H CMC 6,0 % 250 kHz do 300 kHz od 5 H do 10 H CMC 7,2 % 50 Hz do 100 Hz od 10 H do 50 H CMC 0,18 % 100 Hz do 500 Hz od 10 H do 50 H CMC 0,15 % 500 Hz do 800 Hz od 10 H do 50 H CMC 0,22 % 800 Hz do 2 kHz od 10 H do 50 H CMC 0,24 % 2 kHz do 3 kHz od 10 H do 50 H CMC 0,28 % 3 kHz do 5 kHz od 10 H do 50 H CMC 0,35 % 5 kHz do 7 kHz od 10 H do 50 H CMC 0,43 % 7 kHz do 10 kHz od 10 H do 50 H CMC 0,55 % 10 kHz do 15 kHz od 10 H do 50 H CMC 0,74 % 15 kHz do 20 kHz od 10 H do 50 H CMC 0,93 % 20 kHz do 25 kHz od 10 H do 50 H CMC 1,2 % 25 kHz do 30 kHz od 10 H do 50 H CMC 1,4 % 30 kHz do 40 kHz od 10 H do 50 H CMC 1,8 % 40 kHz do 50 kHz od 10 H do 50 H CMC 2,1 % 50 kHz do 60 kHz od 10 H do 50 H CMC 2,5 % 60 kHz do 70 kHz od 10 H do 50 H CMC 2,9 % 70 kHz do 80 kHz od 10 H do 50 H CMC 3,3 % 80 kHz do 90 kHz od 10 H do 50 H CMC 3,7 % 90 kHz do 100 kHz od 10 H do 50 H CMC 4,1 % 50 Hz do 100 Hz od 50 H do 100 H CMC 0,18 % 100 Hz do 500 Hz od 50 H do 100 H CMC 0,15 % 500 Hz do 800 Hz od 50 H do 100 H CMC 0,22 % 800 Hz do 1 kHz od 50 H do 100 H CMC 0,24 % 1 kHz do 2 kHz od 50 H do 100 H CMC 0,31 % 2 kHz do 3 kHz od 50 H do 100 H CMC 0,39 % 3 kHz do 5 kHz od 50 H do 100 H CMC 0,55 % 5 kHz do 7 kHz od 50 H do 100 H CMC 0,70 % 7 kHz do 10 kHz od 50 H do 100 H CMC 0,93 % 10 kHz do 15 kHz od 50 H do 100 H CMC 1,4 % 15 kHz do 20 kHz od 50 H do 100 H CMC 1,8 % 20 kHz do 25 kHz od 50 H do 100 H CMC 2,1 % 25 kHz do 30 kHz od 50 H do 100 H CMC 2,5 % 20 Hz do 35 Hz od 100 H do 500 H CMC 0,38 % 35 Hz do 50 Hz od 100 H do 500 H CMC 0,40 % 50 Hz do 70 Hz od 100 H do 500 H CMC 0,28 % 70 Hz do 200 Hz od 100 H do 500 H CMC 0,31 % 200 Hz do 300 Hz od 100 H do 500 H CMC 0,39 % 300 Hz do 400 Hz od 100 H do 500 H CMC 0,47 % 400 Hz do 500 Hz od 100 H do 500 H CMC 0,55 % 500 Hz do 600 Hz od 100 H do 500 H CMC 0,62 % 600 Hz do 700 Hz od 100 H do 500 H CMC 0,70 % 700 Hz do 800 Hz od 100 H do 500 H CMC 0,78 % 800 Hz do 900 Hz od 100 H do 500 H CMC 0,86 % 900 Hz do 2 kHz od 100 H do 500 H CMC 0,93 % 2 kHz do 3 kHz od 100 H do 500 H CMC 1,4 % 3 kHz do 5 kHz od 100 H do 500 H CMC 2,1 % 5 kHz do 7 kHz od 100 H do 500 H CMC 2,9 % 7 kHz do 8 kHz od 100 H do 500 H CMC 3,3 % 8 kHz do 9 kHz od 100 H do 500 H CMC 3,7 % 9 kHz do 10 kHz od 100 H do 500 H CMC 4,1 % 20 Hz do 35 Hz od 500 H do 1 kH CMC 0,38 % 35 Hz do 50 Hz od 500 H do 1 kH CMC 0,40 % 50 Hz do 70 Hz od 500 H do 1 kH CMC 0,28 % 70 Hz do 100 Hz od 500 H do 1 kH CMC 0,31 % 100 Hz do 200 Hz od 500 H do 1 kH CMC 0,31 % 200 Hz do 300 Hz od 500 H do 1 kH CMC 0,39 % 300 Hz do 400 Hz od 500 H do 1 kH CMC 0,47 % 400 Hz do 500 Hz od 500 H do 1 kH CMC 0,55 % 500 Hz do 600 Hz od 500 H do 1 kH CMC 0,62 % 600 Hz do 700 Hz od 500 H do 1 kH CMC 0,70 % 700 Hz do 800 Hz od 500 H do 1 kH CMC 0,78 % 800 Hz do 900 Hz od 500 H do 1 kH CMC 0,86 % 900 Hz do 1 kHz od 500 H do 1 kH CMC 0,93 % Indukčnost / Etalony indukčnosti Kalibrace – elektrické veličiny Přímé měření RLC měřidlem 10 kHz až 15 kHz 1 µH až 5 µH CMC 2,4 % 15 kHz až 20 kHz 1 µH až 5 µH CMC 1,7 % 20 kHz až 25 kHz 1 µH až 5 µH CMC 1,3 % 25 kHz až 30 kHz 1 µH až 5 µH CMC 1,1 % 30 kHz až 40 kHz 1 µH až 5 µH CMC 0,89 % 40 kHz až 50 kHz 1 µH až 5 µH CMC 0,71 % 50 kHz až 60 kHz 1 µH až 5 µH CMC 0,60 % 60 kHz až 70 kHz 1 µH až 5 µH CMC 0,53 % 70 kHz až 80 kHz 1 µH až 5 µH CMC 0,47 % 80 kHz až 90 kHz 1 µH až 5 µH CMC 0,43 % 90 kHz až 100 kHz 1 µH až 5 µH CMC 0,40 % 100 kHz až 150 kHz 1 µH až 5 µH CMC 0,56 % 150 kHz až 200 kHz 1 µH až 5 µH CMC 0,45 % 200 kHz až 250 kHz 1 µH až 5 µH CMC 0,36 % 250 kHz až 300 kHz 1 µH až 5 µH CMC 0,32 % 300 kHz až 400 kHz 1 µH až 5 µH CMC 0,36 % 400 kHz až 500 kHz 1 µH až 5 µH CMC 0,31 % 500 kHz až 700 kHz 1 µH až 5 µH CMC 0,28 % 700 kHz až 1 MHz 1 µH až 5 µH CMC 0,24 % 2 kHz až 3 kHz 5 µH až 10 µH CMC 2,4 % 3 kHz až 5 kHz 5 µH až 10 µH CMC 1,7 % 5 kHz až 7 kHz 5 µH až 10 µH CMC 1,1 % 7 kHz až 10 kHz 5 µH až 10 µH CMC 0,79 % 10 kHz až 15 kHz 5 µH až 10 µH CMC 0,60 % 15 kHz až 20 kHz 5 µH až 10 µH CMC 0,45 % 20 kHz až 25 kHz 5 µH až 10 µH CMC 0,38 % 25 kHz až 30 kHz 5 µH až 10 µH CMC 0,34 % 30 kHz až 40 kHz 5 µH až 10 µH CMC 0,31 % 40 kHz až 50 kHz 5 µH až 10 µH CMC 0,27 % 50 kHz až 60 kHz 5 µH až 10 µH CMC 0,25 % 60 kHz až 100 kHz 5 µH až 10 µH CMC 0,23 % 100 kHz až 150 kHz 5 µH až 10 µH CMC 0,24 % 150 kHz až 200 kHz 5 µH až 10 µH CMC 0,22 % 200 kHz až 500 kHz 5 µH až 10 µH CMC 0,20 % 500 kHz až 1 MHz 5 µH až 10 µH CMC 0,13 % 1 kHz až 2 kHz 10 µH až 50 µH CMC 2,4 % 2 kHz až 3 kHz 10 µH až 50 µH CMC 1,3 % 3 kHz až 5 kHz 10 µH až 50 µH CMC 0,89 % 5 kHz až 7 kHz 10 µH až 50 µH CMC 0,60 % 7 kHz až 10 kHz 10 µH až 50 µH CMC 0,47 % 10 kHz až 15 kHz 10 µH až 50 µH CMC 0,38 % 15 kHz až 20 kHz 10 µH až 50 µH CMC 0,31 % 20 kHz až 25 kHz 10 µH až 50 µH CMC 0,27 % 25 kHz až 30 kHz 10 µH až 50 µH CMC 0,25 % 30 kHz až 50 kHz 10 µH až 50 µH CMC 0,23 % 50 kHz až 70 kHz 10 µH až 50 µH CMC 0,21 % 70 kHz až 100 kHz 10 µH až 50 µH CMC 0,19 % 100 kHz až 250 kHz 10 µH až 50 µH CMC 0,20 % 250 kHz až 300 kHz 10 µH až 50 µH CMC 0,12 % 300 kHz až 1 MHz 10 µH až 50 µH CMC 0,13 % 200 Hz až 300 Hz 50 µH až 100 µH CMC 2,6 % 300 Hz až 400 Hz 50 µH až 100 µH CMC 1,8 % 400 Hz až 500 Hz 50 µH až 100 µH CMC 1,3 % 500 Hz až 600 Hz 50 µH až 100 µH CMC 1,1 % 600 Hz až 700 Hz 50 µH až 100 µH CMC 0,89 % 700 Hz až 800 Hz 50 µH až 100 µH CMC 0,79 % 800 Hz až 900 Hz 50 µH až 100 µH CMC 0,71 % 900 Hz až 1 kHz 50 µH až 100 µH CMC 0,65 % 1 kHz až 2 kHz 50 µH až 100 µH CMC 0,60 % 2 kHz až 3 kHz 50 µH až 100 µH CMC 0,38 % 3 kHz až 5 kHz 50 µH až 100 µH CMC 0,31 % 5 kHz až 10 kHz 50 µH až 100 µH CMC 0,25 % 10 kHz až 15 kHz 50 µH až 100 µH CMC 0,21 % 15 kHz až 30 kHz 50 µH až 100 µH CMC 0,19 % 30 kHz až 50 kHz 50 µH až 100 µH CMC 0,18 % 50 kHz až 100 kHz 50 µH až 100 µH CMC 0,12 % 100 kHz až 250 kHz 50 µH až 100 µH CMC 0,20 % 250 kHz až 300 kHz 50 µH až 100 µH CMC 0,12 % 300 kHz až 1 MHz 50 µH až 100 µH CMC 0,13 % 80 Hz až 90 Hz 100 µH až 500 µH CMC 6,2 % 90 Hz až 100 Hz 100 µH až 500 µH CMC 5,4 % 100 Hz až 200 Hz 100 µH až 500 µH CMC 2,6 % 200 Hz až 300 Hz 100 µH až 500 µH CMC 1,3 % 300 Hz až 400 Hz 100 µH až 500 µH CMC 0,89 % 400 Hz až 500 Hz 100 µH až 500 µH CMC 0,71 % 500 Hz až 600 Hz 100 µH až 500 µH CMC 0,60 % 600 Hz až 700 Hz 100 µH až 500 µH CMC 0,53 % 700 Hz až 800 Hz 100 µH až 500 µH CMC 0,47 % 800 Hz až 900 Hz 100 µH až 500 µH CMC 0,43 % 900 Hz až 1 kHz 100 µH až 500 µH CMC 0,40 % 1 kHz až 2 kHz 100 µH až 500 µH CMC 0,38 % 2 kHz až 3 kHz 100 µH až 500 µH CMC 0,27 % 3 kHz až 5 kHz 100 µH až 500 µH CMC 0,23 % 5 kHz až 10 kHz 100 µH až 500 µH CMC 0,21 % 10 kHz až 25 kHz 100 µH až 500 µH CMC 0,18 % 25 kHz až 30 kHz 100 µH až 500 µH CMC 0,12 % 30 kHz až 100 kHz 100 µH až 500 µH CMC 0,12 % 100 kHz až 300 kHz 100 µH až 500 µH CMC 0,11 % 300 kHz až 1 MHz 100 µH až 500 µH CMC 0,17 % 50 Hz až 60 Hz 500 µH až 1 mH CMC 2,3 % 60 Hz až 70 Hz 500 µH až 1 mH CMC 1,9 % 70 Hz až 80 Hz 500 µH až 1 mH CMC 1,6 % 80 Hz až 100 Hz 500 µH až 1 mH CMC 1,4 % 100 Hz až 200 Hz 500 µH až 1 mH CMC 0,60 % 200 Hz až 300 Hz 500 µH až 1 mH CMC 0,38 % 300 Hz až 400 Hz 500 µH až 1 mH CMC 0,31 % 400 Hz až 500 Hz 500 µH až 1 mH CMC 0,27 % 500 Hz až 600 Hz 500 µH až 1 mH CMC 0,25 % 600 Hz až 900 Hz 500 µH až 1 mH CMC 0,23 % 900 Hz až 1 kHz 500 µH až 1 mH CMC 0,21 % 1 kHz až 2 kHz 500 µH až 1 mH CMC 0,38 % 2 kHz až 3 kHz 500 µH až 1 mH CMC 0,27 % 3 kHz až 5 kHz 500 µH až 1 mH CMC 0,23 % 5 kHz až 10 kHz 500 µH až 1 mH CMC 0,21 % 10 kHz až 25 kHz 500 µH až 1 mH CMC 0,18 % 25 kHz až 100 kHz 500 µH až 1 mH CMC 0,12 % 100 kHz až 300 kHz 500 µH až 1 mH CMC 0,11 % 300 kHz až 1 MHz 500 µH až 1 mH CMC 0,17 % 20 Hz až 30 Hz 1 mH až 5 mH CMC 3,9 % 30 Hz až 40 Hz 1 mH až 5 mH CMC 2,5 % 40 Hz až 50 Hz 1 mH až 5 mH CMC 1,8 % 50 Hz až 60 Hz 1 mH až 5 mH CMC 1,3 % 60 Hz až 80 Hz 1 mH až 5 mH CMC 1,0 % 80 Hz až 90 Hz 1 mH až 5 mH CMC 0,74 % 90 Hz až 100 Hz 1 mH až 5 mH CMC 0,66 % 100 Hz až 200 Hz 1 mH až 5 mH CMC 0,38 % 200 Hz až 300 Hz 1 mH až 5 mH CMC 0,27 % 300 Hz až 500 Hz 1 mH až 5 mH CMC 0,23 % 500 Hz až 700 Hz 1 mH až 5 mH CMC 0,21 % 700 Hz až 1 kHz 1 mH až 5 mH CMC 0,19 % 1 kHz až 3 kHz 1 mH až 5 mH CMC 0,18 % 3 kHz až 100 kHz 1 mH až 5 mH CMC 0,12 % 100 kHz až 300 kHz 1 mH až 5 mH CMC 0,17 % 300 kHz až 600 kHz 1 mH až 5 mH CMC 0,21 % 600 kHz až 1 MHz 1 mH až 5 mH CMC 0,24 % 20 Hz až 30 Hz 5 mH až 10 mH CMC 1,1 % 30 Hz až 40 Hz 5 mH až 10 mH CMC 0,75 % 40 Hz až 50 Hz 5 mH až 10 mH CMC 0,61 % 50 Hz až 60 Hz 5 mH až 10 mH CMC 0,37 % 60 Hz až 70 Hz 5 mH až 10 mH CMC 0,33 % 70 Hz až 80 Hz 5 mH až 10 mH CMC 0,30 % 80 Hz až 90 Hz 5 mH až 10 mH CMC 0,28 % 90 Hz až 100 Hz 5 mH až 10 mH CMC 0,26 % 100 Hz až 200 Hz 5 mH až 10 mH CMC 0,38 % 200 Hz až 300 Hz 5 mH až 10 mH CMC 0,27 % 300 Hz až 500 Hz 5 mH až 10 mH CMC 0,23 % 500 Hz až 700 Hz 5 mH až 10 mH CMC 0,21 % 700 Hz až 1 kHz 5 mH až 10 mH CMC 0,19 % 1 kHz až 3 kHz 5 mH až 10 mH CMC 0,18 % 3 kHz až 100 kHz 5 mH až 10 mH CMC 0,12 % 100 kHz až 300 kHz 5 mH až 10 mH CMC 0,17 % 300 kHz až 600 kHz 5 mH až 10 mH CMC 0,21 % 600 kHz až 1 MHz 5 mH až 10 mH CMC 0,24 % 20 Hz až 30 Hz 10 mH až 50 mH CMC 0,69 % 30 Hz až 40 Hz 10 mH až 50 mH CMC 0,54 % 40 Hz až 50 Hz 10 mH až 50 mH CMC 0,47 % 50 Hz až 60 Hz 10 mH až 50 mH CMC 0,27 % 60 Hz až 80 Hz 10 mH až 50 mH CMC 0,24 % 80 Hz až 100 Hz 10 mH až 50 mH CMC 0,22 % 100 Hz až 250 Hz 10 mH až 50 mH CMC 0,18 % 250 Hz až 1 kHz 10 mH až 50 mH CMC 0,12 % 1 kHz až 30 kHz 10 mH až 50 mH CMC 0,11 % 30 kHz až 100 kHz 10 mH až 50 mH CMC 0,17 % 100 kHz až 200 kHz 10 mH až 50 mH CMC 0,21 % 200 kHz až 300 kHz 10 mH až 50 mH CMC 0,23 % 300 kHz až 400 kHz 10 mH až 50 mH CMC 0,31 % 400 kHz až 500 kHz 10 mH až 50 mH CMC 0,35 % 500 kHz až 700 kHz 10 mH až 50 mH CMC 0,43 % 700 kHz až 1 MHz 10 mH až 50 mH CMC 0,55 % 20 Hz až 30 Hz 50 mH až 100 mH CMC 0,40 % 30 Hz až 50 Hz 50 mH až 100 mH CMC 0,37 % 50 Hz až 60 Hz 50 mH až 100 mH CMC 0,27 % 60 Hz až 80 Hz 50 mH až 100 mH CMC 0,24 % 80 Hz až 100 Hz 50 mH až 100 mH CMC 0,22 % 100 Hz až 250 Hz 50 mH až 100 mH CMC 0,18 % 250 Hz až 1 kHz 50 mH až 100 mH CMC 0,12 % 1 kHz až 30 kHz 50 mH až 100 mH CMC 0,11 % 30 kHz až 100 kHz 50 mH až 100 mH CMC 0,17 % 100 kHz až 200 kHz 50 mH až 100 mH CMC 0,21 % 200 kHz až 300 kHz 50 mH až 100 mH CMC 0,23 % 300 kHz až 400 kHz 50 mH až 100 mH CMC 0,47 % 400 kHz až 500 kHz 50 mH až 100 mH CMC 0,55 % 500 kHz až 600 kHz 50 mH až 100 mH CMC 0,62 % 600 kHz až 700 kHz 50 mH až 100 mH CMC 0,70 % 700 kHz až 800 kHz 50 mH až 100 mH CMC 0,78 % 800 kHz až 1 MHz 50 mH až 100 mH CMC 0,93 % 20 Hz až 30 Hz 100 mH až 500 mH CMC 0,27 % 30 Hz až 50 Hz 100 mH až 500 mH CMC 0,35 % 50 Hz až 100 Hz 100 mH až 500 mH CMC 0,18 % 100 Hz až 1 kHz 100 mH až 500 mH CMC 0,12 % 1 kHz až 30 kHz 100 mH až 500 mH CMC 0,13 % 30 kHz až 60 kHz 100 mH až 500 mH CMC 0,21 % 60 kHz až 100 kHz 100 mH až 500 mH CMC 0,24 % 100 kHz až 150 kHz 100 mH až 500 mH CMC 0,33 % 150 kHz až 200 kHz 100 mH až 500 mH CMC 0,39 % 200 kHz až 250 kHz 100 mH až 500 mH CMC 0,45 % 250 kHz až 300 kHz 100 mH až 500 mH CMC 0,51 % 300 kHz až 400 kHz 100 mH až 500 mH CMC 1,8 % 400 kHz až 500 kHz 100 mH až 500 mH CMC 2,1 % 500 kHz až 600 kHz 100 mH až 500 mH CMC 2,5 % 600 kHz až 700 kHz 100 mH až 500 mH CMC 2,9 % 700 kHz až 800 kHz 100 mH až 500 mH CMC 3,3 % 800 kHz až 900 kHz 100 mH až 500 mH CMC 3,7 % 900 kHz až 1 MHz 100 mH až 500 mH CMC 4,1 % 20 Hz až 30 Hz 500 mH až 1 H CMC 0,27 % 30 Hz až 50 Hz 500 mH až 1 H CMC 0,35 % 50 Hz až 100 Hz 500 mH až 1 H CMC 0,18 % 100 Hz až 1 kHz 500 mH až 1 H CMC 0,12 % 1 kHz až 30 kHz 500 mH až 1 H CMC 0,13 % 30 kHz až 60 kHz 500 mH až 1 H CMC 0,21 % 60 kHz až 100 kHz 500 mH až 1 H CMC 0,24 % 100 kHz až 150 kHz 500 mH až 1 H CMC 0,51 % 150 kHz až 200 kHz 500 mH až 1 H CMC 0,62 % 200 kHz až 250 kHz 500 mH až 1 H CMC 0,74 % 250 kHz až 300 kHz 500 mH až 1 H CMC 0,86 % 300 kHz až 400 kHz 500 mH až 1 H CMC 3,3 % 400 kHz až 500 kHz 500 mH až 1 H CMC 4,1 % 500 kHz až 600 kHz 500 mH až 1 H CMC 4,9 % 600 kHz až 700 kHz 500 mH až 1 H CMC 5,6 % 700 kHz až 800 kHz 500 mH až 1 H CMC 6,4 % 800 kHz až 900 kHz 500 mH až 1 H CMC 7,2 % 900 kHz až 1 MHz 500 mH až 1 H CMC 8,0 % 20 Hz až 50 Hz 1 H až 2 H CMC 0,34 % 50 Hz až 100 Hz 1 H až 2 H CMC 0,18 % 100 Hz až 1 kHz 1 H až 2 H CMC 0,12 % 1 kHz až 5 kHz 1 H až 2 H CMC 0,15 % 5 kHz až 10 kHz 1 H až 2 H CMC 0,24 % 10 kHz až 15 kHz 1 H až 2 H CMC 0,28 % 15 kHz až 20 kHz 1 H až 2 H CMC 0,31 % 20 kHz až 25 kHz 1 H až 2 H CMC 0,35 % 25 kHz až 30 kHz 1 H až 2 H CMC 0,38 % 30 kHz až 50 kHz 1 H až 2 H CMC 0,35 % 50 kHz až 70 kHz 1 H až 2 H CMC 0,43 % 70 kHz až 100 kHz 1 H až 2 H CMC 0,55 % 100 kHz až 150 kHz 1 H až 2 H CMC 1,9 % 150 kHz až 200 kHz 1 H až 2 H CMC 2,5 % 200 kHz až 250 kHz 1 H až 2 H CMC 3,1 % 250 kHz až 300 kHz 1 H až 2 H CMC 3,7 % 300 kHz až 400 kHz 1 H až 2 H CMC 6,4 % 400 kHz až 500 kHz 1 H až 2 H CMC 8,0 % 20 Hz až 50 Hz 2 H až 5 H CMC 0,34 % 50 Hz až 100 Hz 2 H až 5 H CMC 0,18 % 100 Hz až 1 kHz 2 H až 5 H CMC 0,12 % 1 kHz až 5 kHz 2 H až 5 H CMC 0,15 % 5 kHz až 10 kHz 2 H až 5 H CMC 0,24 % 10 kHz až 15 kHz 2 H až 5 H CMC 0,28 % 15 kHz až 20 kHz 2 H až 5 H CMC 0,31 % 20 kHz až 25 kHz 2 H až 5 H CMC 0,35 % 25 kHz až 30 kHz 2 H až 5 H CMC 0,38 % 30 kHz až 50 kHz 2 H až 5 H CMC 0,35 % 50 kHz až 70 kHz 2 H až 5 H CMC 0,43 % 70 kHz až 100 kHz 2 H až 5 H CMC 0,55 % 100 kHz až 150 kHz 2 H až 5 H CMC 1,9 % 150 kHz až 200 kHz 2 H až 5 H CMC 2,5 % 200 kHz až 250 kHz 2 H až 5 H CMC 3,1 % 250 kHz až 300 kHz 2 H až 5 H CMC 3,7 % 50 Hz až 100 Hz 5 H až 10 H CMC 0,18 % 100 Hz až 1 kHz 5 H až 10 H CMC 0,12 % 1 kHz až 5 kHz 5 H až 10 H CMC 0,15 % 5 kHz až 10 kHz 5 H až 10 H CMC 0,24 % 10 kHz až 15 kHz 5 H až 10 H CMC 0,28 % 15 kHz až 20 kHz 5 H až 10 H CMC 0,31 % 20 kHz až 25 kHz 5 H až 10 H CMC 0,35 % 25 kHz až 30 kHz 5 H až 10 H CMC 0,38 % 30 kHz až 40 kHz 5 H až 10 H CMC 0,47 % 40 kHz až 50 kHz 5 H až 10 H CMC 0,55 % 50 kHz až 60 kHz 5 H až 10 H CMC 0,62 % 60 kHz až 70 kHz 5 H až 10 H CMC 0,70 % 70 kHz až 80 kHz 5 H až 10 H CMC 0,78 % 80 kHz až 90 kHz 5 H až 10 H CMC 0,86 % 90 kHz až 100 kHz 5 H až 10 H CMC 0,93 % 100 kHz až 150 kHz 5 H až 10 H CMC 3,7 % 150 kHz až 200 kHz 5 H až 10 H CMC 4,9 % 200 kHz až 250 kHz 5 H až 10 H CMC 6,0 % 250 kHz až 300 kHz 5 H až 10 H CMC 7,2 % 50 Hz až 100 Hz 10 H až 50 H CMC 0,18 % 100 Hz až 500 Hz 10 H až 50 H CMC 0,15 % 500 Hz až 800 Hz 10 H až 50 H CMC 0,22 % 800 Hz až 2 kHz 10 H až 50 H CMC 0,24 % 2 kHz až 3 kHz 10 H až 50 H CMC 0,28 % 3 kHz až 5 kHz 10 H až 50 H CMC 0,35 % 5 kHz až 7 kHz 10 H až 50 H CMC 0,43 % 7 kHz až 10 kHz 10 H až 50 H CMC 0,55 % 10 kHz až 15 kHz 10 H až 50 H CMC 0,74 % 15 kHz až 20 kHz 10 H až 50 H CMC 0,93 % 20 kHz až 25 kHz 10 H až 50 H CMC 1,2 % 25 kHz až 30 kHz 10 H až 50 H CMC 1,4 % 30 kHz až 40 kHz 10 H až 50 H CMC 1,8 % 40 kHz až 50 kHz 10 H až 50 H CMC 2,1 % 50 kHz až 60 kHz 10 H až 50 H CMC 2,5 % 60 kHz až 70 kHz 10 H až 50 H CMC 2,9 % 70 kHz až 80 kHz 10 H až 50 H CMC 3,3 % 80 kHz až 90 kHz 10 H až 50 H CMC 3,7 % 90 kHz až 100 kHz 10 H až 50 H CMC 4,1 % 50 Hz až 100 Hz 50 H až 100 H CMC 0,18 % 100 Hz až 500 Hz 50 H až 100 H CMC 0,15 % 500 Hz až 800 Hz 50 H až 100 H CMC 0,22 % 800 Hz až 1 kHz 50 H až 100 H CMC 0,24 % 1 kHz až 2 kHz 50 H až 100 H CMC 0,31 % 2 kHz až 3 kHz 50 H až 100 H CMC 0,39 % 3 kHz až 5 kHz 50 H až 100 H CMC 0,55 % 5 kHz až 7 kHz 50 H až 100 H CMC 0,70 % 7 kHz až 10 kHz 50 H až 100 H CMC 0,93 % 10 kHz až 15 kHz 50 H až 100 H CMC 1,4 % 15 kHz až 20 kHz 50 H až 100 H CMC 1,8 % 20 kHz až 25 kHz 50 H až 100 H CMC 2,1 % 25 kHz až 30 kHz 50 H až 100 H CMC 2,5 % 20 Hz až 35 Hz 100 H až 500 H CMC 0,38 % 35 Hz až 50 Hz 100 H až 500 H CMC 0,40 % 50 Hz až 70 Hz 100 H až 500 H CMC 0,28 % 70 Hz až 200 Hz 100 H až 500 H CMC 0,31 % 200 Hz až 300 Hz 100 H až 500 H CMC 0,39 % 300 Hz až 400 Hz 100 H až 500 H CMC 0,47 % 400 Hz až 500 Hz 100 H až 500 H CMC 0,55 % 500 Hz až 600 Hz 100 H až 500 H CMC 0,62 % 600 Hz až 700 Hz 100 H až 500 H CMC 0,70 % 700 Hz až 800 Hz 100 H až 500 H CMC 0,78 % 800 Hz až 900 Hz 100 H až 500 H CMC 0,86 % 900 Hz až 2 kHz 100 H až 500 H CMC 0,93 % 2 kHz až 3 kHz 100 H až 500 H CMC 1,4 % 3 kHz až 5 kHz 100 H až 500 H CMC 2,1 % 5 kHz až 7 kHz 100 H až 500 H CMC 2,9 % 7 kHz až 8 kHz 100 H až 500 H CMC 3,3 % 8 kHz až 9 kHz 100 H až 500 H CMC 3,7 % 9 kHz až 10 kHz 100 H až 500 H CMC 4,1 % 20 Hz až 35 Hz 500 H až 1 kH CMC 0,38 % 35 Hz až 50 Hz 500 H až 1 kH CMC 0,40 % 50 Hz až 70 Hz 500 H až 1 kH CMC 0,28 % 70 Hz až 100 Hz 500 H až 1 kH CMC 0,31 % 100 Hz až 200 Hz 500 H až 1 kH CMC 0,31 % 200 Hz až 300 Hz 500 H až 1 kH CMC 0,39 % 300 Hz až 400 Hz 500 H až 1 kH CMC 0,47 % 400 Hz až 500 Hz 500 H až 1 kH CMC 0,55 % 500 Hz až 600 Hz 500 H až 1 kH CMC 0,62 % 600 Hz až 700 Hz 500 H až 1 kH CMC 0,70 % 700 Hz až 800 Hz 500 H až 1 kH CMC 0,78 % 800 Hz až 900 Hz 500 H až 1 kH CMC 0,86 % 900 Hz až 1 kHz 500 H až 1 kH CMC 0,93 % TP8, TP24 Indukcyjnosc / Wzorce indukcyjnosci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem RLC 10 kHz do 15 kHz od 1 µH do 5 µH CMC 2,4 % 15 kHz do 20 kHz od 1 µH do 5 µH CMC 1,7 % 20 kHz do 25 kHz od 1 µH do 5 µH CMC 1,3 % 25 kHz do 30 kHz od 1 µH do 5 µH CMC 1,1 % 30 kHz do 40 kHz od 1 µH do 5 µH CMC 0,89 % 40 kHz do 50 kHz od 1 µH do 5 µH CMC 0,71 % 50 kHz do 60 kHz od 1 µH do 5 µH CMC 0,60 % 60 kHz do 70 kHz od 1 µH do 5 µH CMC 0,53 % 70 kHz do 80 kHz od 1 µH do 5 µH CMC 0,47 % 80 kHz do 90 kHz od 1 µH do 5 µH CMC 0,43 % 90 kHz do 100 kHz od 1 µH do 5 µH CMC 0,40 % 100 kHz do 150 kHz od 1 µH do 5 µH CMC 0,56 % 150 kHz do 200 kHz od 1 µH do 5 µH CMC 0,45 % 200 kHz do 250 kHz od 1 µH do 5 µH CMC 0,36 % 250 kHz do 300 kHz od 1 µH do 5 µH CMC 0,32 % 300 kHz do 400 kHz od 1 µH do 5 µH CMC 0,36 % 400 kHz do 500 kHz od 1 µH do 5 µH CMC 0,31 % 500 kHz do 700 kHz od 1 µH do 5 µH CMC 0,28 % 700 kHz do 1 MHz od 1 µH do 5 µH CMC 0,24 % 2 kHz do 3 kHz od 5 µH do 10 µH CMC 2,4 % 3 kHz do 5 kHz od 5 µH do 10 µH CMC 1,7 % 5 kHz do 7 kHz od 5 µH do 10 µH CMC 1,1 % 7 kHz do 10 kHz od 5 µH do 10 µH CMC 0,79 % 10 kHz do 15 kHz od 5 µH do 10 µH CMC 0,60 % 15 kHz do 20 kHz od 5 µH do 10 µH CMC 0,45 % 20 kHz do 25 kHz od 5 µH do 10 µH CMC 0,38 % 25 kHz do 30 kHz od 5 µH do 10 µH CMC 0,34 % 30 kHz do 40 kHz od 5 µH do 10 µH CMC 0,31 % 40 kHz do 50 kHz od 5 µH do 10 µH CMC 0,27 % 50 kHz do 60 kHz od 5 µH do 10 µH CMC 0,25 % 60 kHz do 100 kHz od 5 µH do 10 µH CMC 0,23 % 100 kHz do 150 kHz od 5 µH do 10 µH CMC 0,24 % 150 kHz do 200 kHz od 5 µH do 10 µH CMC 0,22 % 200 kHz do 500 kHz od 5 µH do 10 µH CMC 0,20 % 500 kHz do 1 MHz od 5 µH do 10 µH CMC 0,13 % 1 kHz do 2 kHz od 10 µH do 50 µH CMC 2,4 % 2 kHz do 3 kHz od 10 µH do 50 µH CMC 1,3 % 3 kHz do 5 kHz od 10 µH do 50 µH CMC 0,89 % 5 kHz do 7 kHz od 10 µH do 50 µH CMC 0,60 % 7 kHz do 10 kHz od 10 µH do 50 µH CMC 0,47 % 10 kHz do 15 kHz od 10 µH do 50 µH CMC 0,38 % 15 kHz do 20 kHz od 10 µH do 50 µH CMC 0,31 % 20 kHz do 25 kHz od 10 µH do 50 µH CMC 0,27 % 25 kHz do 30 kHz od 10 µH do 50 µH CMC 0,25 % 30 kHz do 50 kHz od 10 µH do 50 µH CMC 0,23 % 50 kHz do 70 kHz od 10 µH do 50 µH CMC 0,21 % 70 kHz do 100 kHz od 10 µH do 50 µH CMC 0,19 % 100 kHz do 250 kHz od 10 µH do 50 µH CMC 0,20 % 250 kHz do 300 kHz od 10 µH do 50 µH CMC 0,12 % 300 kHz do 1 MHz od 10 µH do 50 µH CMC 0,13 % 200 Hz do 300 Hz od 50 µH do 100 µH CMC 2,6 % 300 Hz do 400 Hz od 50 µH do 100 µH CMC 1,8 % 400 Hz do 500 Hz od 50 µH do 100 µH CMC 1,3 % 500 Hz do 600 Hz od 50 µH do 100 µH CMC 1,1 % 600 Hz do 700 Hz od 50 µH do 100 µH CMC 0,89 % 700 Hz do 800 Hz od 50 µH do 100 µH CMC 0,79 % 800 Hz do 900 Hz od 50 µH do 100 µH CMC 0,71 % 900 Hz do 1 kHz od 50 µH do 100 µH CMC 0,65 % 1 kHz do 2 kHz od 50 µH do 100 µH CMC 0,60 % 2 kHz do 3 kHz od 50 µH do 100 µH CMC 0,38 % 3 kHz do 5 kHz od 50 µH do 100 µH CMC 0,31 % 5 kHz do 10 kHz od 50 µH do 100 µH CMC 0,25 % 10 kHz do 15 kHz od 50 µH do 100 µH CMC 0,21 % 15 kHz do 30 kHz od 50 µH do 100 µH CMC 0,19 % 30 kHz do 50 kHz od 50 µH do 100 µH CMC 0,18 % 50 kHz do 100 kHz od 50 µH do 100 µH CMC 0,12 % 100 kHz do 250 kHz od 50 µH do 100 µH CMC 0,20 % 250 kHz do 300 kHz od 50 µH do 100 µH CMC 0,12 % 300 kHz do 1 MHz od 50 µH do 100 µH CMC 0,13 % 80 Hz do 90 Hz od 100 µH do 500 µH CMC 6,2 % 90 Hz do 100 Hz od 100 µH do 500 µH CMC 5,4 % 100 Hz do 200 Hz od 100 µH do 500 µH CMC 2,6 % 200 Hz do 300 Hz od 100 µH do 500 µH CMC 1,3 % 300 Hz do 400 Hz od 100 µH do 500 µH CMC 0,89 % 400 Hz do 500 Hz od 100 µH do 500 µH CMC 0,71 % 500 Hz do 600 Hz od 100 µH do 500 µH CMC 0,60 % 600 Hz do 700 Hz od 100 µH do 500 µH CMC 0,53 % 700 Hz do 800 Hz od 100 µH do 500 µH CMC 0,47 % 800 Hz do 900 Hz od 100 µH do 500 µH CMC 0,43 % 900 Hz do 1 kHz od 100 µH do 500 µH CMC 0,40 % 1 kHz do 2 kHz od 100 µH do 500 µH CMC 0,38 % 2 kHz do 3 kHz od 100 µH do 500 µH CMC 0,27 % 3 kHz do 5 kHz od 100 µH do 500 µH CMC 0,23 % 5 kHz do 10 kHz od 100 µH do 500 µH CMC 0,21 % 10 kHz do 25 kHz od 100 µH do 500 µH CMC 0,18 % 25 kHz do 30 kHz od 100 µH do 500 µH CMC 0,12 % 30 kHz do 100 kHz od 100 µH do 500 µH CMC 0,12 % 100 kHz do 300 kHz od 100 µH do 500 µH CMC 0,11 % 300 kHz do 1 MHz od 100 µH do 500 µH CMC 0,17 % 50 Hz do 60 Hz od 500 µH do 1 mH CMC 2,3 % 60 Hz do 70 Hz od 500 µH do 1 mH CMC 1,9 % 70 Hz do 80 Hz od 500 µH do 1 mH CMC 1,6 % 80 Hz do 100 Hz od 500 µH do 1 mH CMC 1,4 % 100 Hz do 200 Hz od 500 µH do 1 mH CMC 0,60 % 200 Hz do 300 Hz od 500 µH do 1 mH CMC 0,38 % 300 Hz do 400 Hz od 500 µH do 1 mH CMC 0,31 % 400 Hz do 500 Hz od 500 µH do 1 mH CMC 0,27 % 500 Hz do 600 Hz od 500 µH do 1 mH CMC 0,25 % 600 Hz do 900 Hz od 500 µH do 1 mH CMC 0,23 % 900 Hz do 1 kHz od 500 µH do 1 mH CMC 0,21 % 1 kHz do 2 kHz od 500 µH do 1 mH CMC 0,38 % 2 kHz do 3 kHz od 500 µH do 1 mH CMC 0,27 % 3 kHz do 5 kHz od 500 µH do 1 mH CMC 0,23 % 5 kHz do 10 kHz od 500 µH do 1 mH CMC 0,21 % 10 kHz do 25 kHz od 500 µH do 1 mH CMC 0,18 % 25 kHz do 100 kHz od 500 µH do 1 mH CMC 0,12 % 100 kHz do 300 kHz od 500 µH do 1 mH CMC 0,11 % 300 kHz do 1 MHz od 500 µH do 1 mH CMC 0,17 % 20 Hz do 30 Hz od 1 mH do 5 mH CMC 3,9 % 30 Hz do 40 Hz od 1 mH do 5 mH CMC 2,5 % 40 Hz do 50 Hz od 1 mH do 5 mH CMC 1,8 % 50 Hz do 60 Hz od 1 mH do 5 mH CMC 1,3 % 60 Hz do 80 Hz od 1 mH do 5 mH CMC 1,0 % 80 Hz do 90 Hz od 1 mH do 5 mH CMC 0,74 % 90 Hz do 100 Hz od 1 mH do 5 mH CMC 0,66 % 100 Hz do 200 Hz od 1 mH do 5 mH CMC 0,38 % 200 Hz do 300 Hz od 1 mH do 5 mH CMC 0,27 % 300 Hz do 500 Hz od 1 mH do 5 mH CMC 0,23 % 500 Hz do 700 Hz od 1 mH do 5 mH CMC 0,21 % 700 Hz do 1 kHz od 1 mH do 5 mH CMC 0,19 % 1 kHz do 3 kHz od 1 mH do 5 mH CMC 0,18 % 3 kHz do 100 kHz od 1 mH do 5 mH CMC 0,12 % 100 kHz do 300 kHz od 1 mH do 5 mH CMC 0,17 % 300 kHz do 600 kHz od 1 mH do 5 mH CMC 0,21 % 600 kHz do 1 MHz od 1 mH do 5 mH CMC 0,24 % 20 Hz do 30 Hz od 5 mH do 10 mH CMC 1,1 % 30 Hz do 40 Hz od 5 mH do 10 mH CMC 0,75 % 40 Hz do 50 Hz od 5 mH do 10 mH CMC 0,61 % 50 Hz do 60 Hz od 5 mH do 10 mH CMC 0,37 % 60 Hz do 70 Hz od 5 mH do 10 mH CMC 0,33 % 70 Hz do 80 Hz od 5 mH do 10 mH CMC 0,30 % 80 Hz do 90 Hz od 5 mH do 10 mH CMC 0,28 % 90 Hz do 100 Hz od 5 mH do 10 mH CMC 0,26 % 100 Hz do 200 Hz od 5 mH do 10 mH CMC 0,38 % 200 Hz do 300 Hz od 5 mH do 10 mH CMC 0,27 % 300 Hz do 500 Hz od 5 mH do 10 mH CMC 0,23 % 500 Hz do 700 Hz od 5 mH do 10 mH CMC 0,21 % 700 Hz do 1 kHz od 5 mH do 10 mH CMC 0,19 % 1 kHz do 3 kHz od 5 mH do 10 mH CMC 0,18 % 3 kHz do 100 kHz od 5 mH do 10 mH CMC 0,12 % 100 kHz do 300 kHz od 5 mH do 10 mH CMC 0,17 % 300 kHz do 600 kHz od 5 mH do 10 mH CMC 0,21 % 600 kHz do 1 MHz od 5 mH do 10 mH CMC 0,24 % 20 Hz do 30 Hz od 10 mH do 50 mH CMC 0,69 % 30 Hz do 40 Hz od 10 mH do 50 mH CMC 0,54 % 40 Hz do 50 Hz od 10 mH do 50 mH CMC 0,47 % 50 Hz do 60 Hz od 10 mH do 50 mH CMC 0,27 % 60 Hz do 80 Hz od 10 mH do 50 mH CMC 0,24 % 80 Hz do 100 Hz od 10 mH do 50 mH CMC 0,22 % 100 Hz do 250 Hz od 10 mH do 50 mH CMC 0,18 % 250 Hz do 1 kHz od 10 mH do 50 mH CMC 0,12 % 1 kHz do 30 kHz od 10 mH do 50 mH CMC 0,11 % 30 kHz do 100 kHz od 10 mH do 50 mH CMC 0,17 % 100 kHz do 200 kHz od 10 mH do 50 mH CMC 0,21 % 200 kHz do 300 kHz od 10 mH do 50 mH CMC 0,23 % 300 kHz do 400 kHz od 10 mH do 50 mH CMC 0,31 % 400 kHz do 500 kHz od 10 mH do 50 mH CMC 0,35 % 500 kHz do 700 kHz od 10 mH do 50 mH CMC 0,43 % 700 kHz do 1 MHz od 10 mH do 50 mH CMC 0,55 % 20 Hz do 30 Hz od 50 mH do 100 mH CMC 0,40 % 30 Hz do 50 Hz od 50 mH do 100 mH CMC 0,37 % 50 Hz do 60 Hz od 50 mH do 100 mH CMC 0,27 % 60 Hz do 80 Hz od 50 mH do 100 mH CMC 0,24 % 80 Hz do 100 Hz od 50 mH do 100 mH CMC 0,22 % 100 Hz do 250 Hz od 50 mH do 100 mH CMC 0,18 % 250 Hz do 1 kHz od 50 mH do 100 mH CMC 0,12 % 1 kHz do 30 kHz od 50 mH do 100 mH CMC 0,11 % 30 kHz do 100 kHz od 50 mH do 100 mH CMC 0,17 % 100 kHz do 200 kHz od 50 mH do 100 mH CMC 0,21 % 200 kHz do 300 kHz od 50 mH do 100 mH CMC 0,23 % 300 kHz do 400 kHz od 50 mH do 100 mH CMC 0,47 % 400 kHz do 500 kHz od 50 mH do 100 mH CMC 0,55 % 500 kHz do 600 kHz od 50 mH do 100 mH CMC 0,62 % 600 kHz do 700 kHz od 50 mH do 100 mH CMC 0,70 % 700 kHz do 800 kHz od 50 mH do 100 mH CMC 0,78 % 800 kHz do 1 MHz od 50 mH do 100 mH CMC 0,93 % 20 Hz do 30 Hz od 100 mH do 500 mH CMC 0,27 % 30 Hz do 50 Hz od 100 mH do 500 mH CMC 0,35 % 50 Hz do 100 Hz od 100 mH do 500 mH CMC 0,18 % 100 Hz do 1 kHz od 100 mH do 500 mH CMC 0,12 % 1 kHz do 30 kHz od 100 mH do 500 mH CMC 0,13 % 30 kHz do 60 kHz od 100 mH do 500 mH CMC 0,21 % 60 kHz do 100 kHz od 100 mH do 500 mH CMC 0,24 % 100 kHz do 150 kHz od 100 mH do 500 mH CMC 0,33 % 150 kHz do 200 kHz od 100 mH do 500 mH CMC 0,39 % 200 kHz do 250 kHz od 100 mH do 500 mH CMC 0,45 % 250 kHz do 300 kHz od 100 mH do 500 mH CMC 0,51 % 300 kHz do 400 kHz od 100 mH do 500 mH CMC 1,8 % 400 kHz do 500 kHz od 100 mH do 500 mH CMC 2,1 % 500 kHz do 600 kHz od 100 mH do 500 mH CMC 2,5 % 600 kHz do 700 kHz od 100 mH do 500 mH CMC 2,9 % 700 kHz do 800 kHz od 100 mH do 500 mH CMC 3,3 % 800 kHz do 900 kHz od 100 mH do 500 mH CMC 3,7 % 900 kHz do 1 MHz od 100 mH do 500 mH CMC 4,1 % 20 Hz do 30 Hz od 500 mH do 1 H CMC 0,27 % 30 Hz do 50 Hz od 500 mH do 1 H CMC 0,35 % 50 Hz do 100 Hz od 500 mH do 1 H CMC 0,18 % 100 Hz do 1 kHz od 500 mH do 1 H CMC 0,12 % 1 kHz do 30 kHz od 500 mH do 1 H CMC 0,13 % 30 kHz do 60 kHz od 500 mH do 1 H CMC 0,21 % 60 kHz do 100 kHz od 500 mH do 1 H CMC 0,24 % 100 kHz do 150 kHz od 500 mH do 1 H CMC 0,51 % 150 kHz do 200 kHz od 500 mH do 1 H CMC 0,62 % 200 kHz do 250 kHz od 500 mH do 1 H CMC 0,74 % 250 kHz do 300 kHz od 500 mH do 1 H CMC 0,86 % 300 kHz do 400 kHz od 500 mH do 1 H CMC 3,3 % 400 kHz do 500 kHz od 500 mH do 1 H CMC 4,1 % 500 kHz do 600 kHz od 500 mH do 1 H CMC 4,9 % 600 kHz do 700 kHz od 500 mH do 1 H CMC 5,6 % 700 kHz do 800 kHz od 500 mH do 1 H CMC 6,4 % 800 kHz do 900 kHz od 500 mH do 1 H CMC 7,2 % 900 kHz do 1 MHz od 500 mH do 1 H CMC 8,0 % 20 Hz do 50 Hz od 1 H do 2 H CMC 0,34 % 50 Hz do 100 Hz od 1 H do 2 H CMC 0,18 % 100 Hz do 1 kHz od 1 H do 2 H CMC 0,12 % 1 kHz do 5 kHz od 1 H do 2 H CMC 0,15 % 5 kHz do 10 kHz od 1 H do 2 H CMC 0,24 % 10 kHz do 15 kHz od 1 H do 2 H CMC 0,28 % 15 kHz do 20 kHz od 1 H do 2 H CMC 0,31 % 20 kHz do 25 kHz od 1 H do 2 H CMC 0,35 % 25 kHz do 30 kHz od 1 H do 2 H CMC 0,38 % 30 kHz do 50 kHz od 1 H do 2 H CMC 0,35 % 50 kHz do 70 kHz od 1 H do 2 H CMC 0,43 % 70 kHz do 100 kHz od 1 H do 2 H CMC 0,55 % 100 kHz do 150 kHz od 1 H do 2 H CMC 1,9 % 150 kHz do 200 kHz od 1 H do 2 H CMC 2,5 % 200 kHz do 250 kHz od 1 H do 2 H CMC 3,1 % 250 kHz do 300 kHz od 1 H do 2 H CMC 3,7 % 300 kHz do 400 kHz od 1 H do 2 H CMC 6,4 % 400 kHz do 500 kHz od 1 H do 2 H CMC 8,0 % 20 Hz do 50 Hz od 2 H do 5 H CMC 0,34 % 50 Hz do 100 Hz od 2 H do 5 H CMC 0,18 % 100 Hz do 1 kHz od 2 H do 5 H CMC 0,12 % 1 kHz do 5 kHz od 2 H do 5 H CMC 0,15 % 5 kHz do 10 kHz od 2 H do 5 H CMC 0,24 % 10 kHz do 15 kHz od 2 H do 5 H CMC 0,28 % 15 kHz do 20 kHz od 2 H do 5 H CMC 0,31 % 20 kHz do 25 kHz od 2 H do 5 H CMC 0,35 % 25 kHz do 30 kHz od 2 H do 5 H CMC 0,38 % 30 kHz do 50 kHz od 2 H do 5 H CMC 0,35 % 50 kHz do 70 kHz od 2 H do 5 H CMC 0,43 % 70 kHz do 100 kHz od 2 H do 5 H CMC 0,55 % 100 kHz do 150 kHz od 2 H do 5 H CMC 1,9 % 150 kHz do 200 kHz od 2 H do 5 H CMC 2,5 % 200 kHz do 250 kHz od 2 H do 5 H CMC 3,1 % 250 kHz do 300 kHz od 2 H do 5 H CMC 3,7 % 50 Hz do 100 Hz od 5 H do 10 H CMC 0,18 % 100 Hz do 1 kHz od 5 H do 10 H CMC 0,12 % 1 kHz do 5 kHz od 5 H do 10 H CMC 0,15 % 5 kHz do 10 kHz od 5 H do 10 H CMC 0,24 % 10 kHz do 15 kHz od 5 H do 10 H CMC 0,28 % 15 kHz do 20 kHz od 5 H do 10 H CMC 0,31 % 20 kHz do 25 kHz od 5 H do 10 H CMC 0,35 % 25 kHz do 30 kHz od 5 H do 10 H CMC 0,38 % 30 kHz do 40 kHz od 5 H do 10 H CMC 0,47 % 40 kHz do 50 kHz od 5 H do 10 H CMC 0,55 % 50 kHz do 60 kHz od 5 H do 10 H CMC 0,62 % 60 kHz do 70 kHz od 5 H do 10 H CMC 0,70 % 70 kHz do 80 kHz od 5 H do 10 H CMC 0,78 % 80 kHz do 90 kHz od 5 H do 10 H CMC 0,86 % 90 kHz do 100 kHz od 5 H do 10 H CMC 0,93 % 100 kHz do 150 kHz od 5 H do 10 H CMC 3,7 % 150 kHz do 200 kHz od 5 H do 10 H CMC 4,9 % 200 kHz do 250 kHz od 5 H do 10 H CMC 6,0 % 250 kHz do 300 kHz od 5 H do 10 H CMC 7,2 % 50 Hz do 100 Hz od 10 H do 50 H CMC 0,18 % 100 Hz do 500 Hz od 10 H do 50 H CMC 0,15 % 500 Hz do 800 Hz od 10 H do 50 H CMC 0,22 % 800 Hz do 2 kHz od 10 H do 50 H CMC 0,24 % 2 kHz do 3 kHz od 10 H do 50 H CMC 0,28 % 3 kHz do 5 kHz od 10 H do 50 H CMC 0,35 % 5 kHz do 7 kHz od 10 H do 50 H CMC 0,43 % 7 kHz do 10 kHz od 10 H do 50 H CMC 0,55 % 10 kHz do 15 kHz od 10 H do 50 H CMC 0,74 % 15 kHz do 20 kHz od 10 H do 50 H CMC 0,93 % 20 kHz do 25 kHz od 10 H do 50 H CMC 1,2 % 25 kHz do 30 kHz od 10 H do 50 H CMC 1,4 % 30 kHz do 40 kHz od 10 H do 50 H CMC 1,8 % 40 kHz do 50 kHz od 10 H do 50 H CMC 2,1 % 50 kHz do 60 kHz od 10 H do 50 H CMC 2,5 % 60 kHz do 70 kHz od 10 H do 50 H CMC 2,9 % 70 kHz do 80 kHz od 10 H do 50 H CMC 3,3 % 80 kHz do 90 kHz od 10 H do 50 H CMC 3,7 % 90 kHz do 100 kHz od 10 H do 50 H CMC 4,1 % 50 Hz do 100 Hz od 50 H do 100 H CMC 0,18 % 100 Hz do 500 Hz od 50 H do 100 H CMC 0,15 % 500 Hz do 800 Hz od 50 H do 100 H CMC 0,22 % 800 Hz do 1 kHz od 50 H do 100 H CMC 0,24 % 1 kHz do 2 kHz od 50 H do 100 H CMC 0,31 % 2 kHz do 3 kHz od 50 H do 100 H CMC 0,39 % 3 kHz do 5 kHz od 50 H do 100 H CMC 0,55 % 5 kHz do 7 kHz od 50 H do 100 H CMC 0,70 % 7 kHz do 10 kHz od 50 H do 100 H CMC 0,93 % 10 kHz do 15 kHz od 50 H do 100 H CMC 1,4 % 15 kHz do 20 kHz od 50 H do 100 H CMC 1,8 % 20 kHz do 25 kHz od 50 H do 100 H CMC 2,1 % 25 kHz do 30 kHz od 50 H do 100 H CMC 2,5 % 20 Hz do 35 Hz od 100 H do 500 H CMC 0,38 % 35 Hz do 50 Hz od 100 H do 500 H CMC 0,40 % 50 Hz do 70 Hz od 100 H do 500 H CMC 0,28 % 70 Hz do 200 Hz od 100 H do 500 H CMC 0,31 % 200 Hz do 300 Hz od 100 H do 500 H CMC 0,39 % 300 Hz do 400 Hz od 100 H do 500 H CMC 0,47 % 400 Hz do 500 Hz od 100 H do 500 H CMC 0,55 % 500 Hz do 600 Hz od 100 H do 500 H CMC 0,62 % 600 Hz do 700 Hz od 100 H do 500 H CMC 0,70 % 700 Hz do 800 Hz od 100 H do 500 H CMC 0,78 % 800 Hz do 900 Hz od 100 H do 500 H CMC 0,86 % 900 Hz do 2 kHz od 100 H do 500 H CMC 0,93 % 2 kHz do 3 kHz od 100 H do 500 H CMC 1,4 % 3 kHz do 5 kHz od 100 H do 500 H CMC 2,1 % 5 kHz do 7 kHz od 100 H do 500 H CMC 2,9 % 7 kHz do 8 kHz od 100 H do 500 H CMC 3,3 % 8 kHz do 9 kHz od 100 H do 500 H CMC 3,7 % 9 kHz do 10 kHz od 100 H do 500 H CMC 4,1 % 20 Hz do 35 Hz od 500 H do 1 kH CMC 0,38 % 35 Hz do 50 Hz od 500 H do 1 kH CMC 0,40 % 50 Hz do 70 Hz od 500 H do 1 kH CMC 0,28 % 70 Hz do 100 Hz od 500 H do 1 kH CMC 0,31 % 100 Hz do 200 Hz od 500 H do 1 kH CMC 0,31 % 200 Hz do 300 Hz od 500 H do 1 kH CMC 0,39 % 300 Hz do 400 Hz od 500 H do 1 kH CMC 0,47 % 400 Hz do 500 Hz od 500 H do 1 kH CMC 0,55 % 500 Hz do 600 Hz od 500 H do 1 kH CMC 0,62 % 600 Hz do 700 Hz od 500 H do 1 kH CMC 0,70 % 700 Hz do 800 Hz od 500 H do 1 kH CMC 0,78 % 800 Hz do 900 Hz od 500 H do 1 kH CMC 0,86 % 900 Hz do 1 kHz od 500 H do 1 kH CMC 0,93 % Indukcnost / Etalony indukcnosti Kalibrace – elektricke veliciny Prime mereni RLC meridlem 10 kHz az 15 kHz 1 µH az 5 µH CMC 2,4 % 15 kHz az 20 kHz 1 µH az 5 µH CMC 1,7 % 20 kHz az 25 kHz 1 µH az 5 µH CMC 1,3 % 25 kHz az 30 kHz 1 µH az 5 µH CMC 1,1 % 30 kHz az 40 kHz 1 µH az 5 µH CMC 0,89 % 40 kHz az 50 kHz 1 µH az 5 µH CMC 0,71 % 50 kHz az 60 kHz 1 µH az 5 µH CMC 0,60 % 60 kHz az 70 kHz 1 µH az 5 µH CMC 0,53 % 70 kHz az 80 kHz 1 µH az 5 µH CMC 0,47 % 80 kHz az 90 kHz 1 µH az 5 µH CMC 0,43 % 90 kHz az 100 kHz 1 µH az 5 µH CMC 0,40 % 100 kHz az 150 kHz 1 µH az 5 µH CMC 0,56 % 150 kHz az 200 kHz 1 µH az 5 µH CMC 0,45 % 200 kHz az 250 kHz 1 µH az 5 µH CMC 0,36 % 250 kHz az 300 kHz 1 µH az 5 µH CMC 0,32 % 300 kHz az 400 kHz 1 µH az 5 µH CMC 0,36 % 400 kHz az 500 kHz 1 µH az 5 µH CMC 0,31 % 500 kHz az 700 kHz 1 µH az 5 µH CMC 0,28 % 700 kHz az 1 MHz 1 µH az 5 µH CMC 0,24 % 2 kHz az 3 kHz 5 µH az 10 µH CMC 2,4 % 3 kHz az 5 kHz 5 µH az 10 µH CMC 1,7 % 5 kHz az 7 kHz 5 µH az 10 µH CMC 1,1 % 7 kHz az 10 kHz 5 µH az 10 µH CMC 0,79 % 10 kHz az 15 kHz 5 µH az 10 µH CMC 0,60 % 15 kHz az 20 kHz 5 µH az 10 µH CMC 0,45 % 20 kHz az 25 kHz 5 µH az 10 µH CMC 0,38 % 25 kHz az 30 kHz 5 µH az 10 µH CMC 0,34 % 30 kHz az 40 kHz 5 µH az 10 µH CMC 0,31 % 40 kHz az 50 kHz 5 µH az 10 µH CMC 0,27 % 50 kHz az 60 kHz 5 µH az 10 µH CMC 0,25 % 60 kHz az 100 kHz 5 µH az 10 µH CMC 0,23 % 100 kHz az 150 kHz 5 µH az 10 µH CMC 0,24 % 150 kHz az 200 kHz 5 µH az 10 µH CMC 0,22 % 200 kHz az 500 kHz 5 µH az 10 µH CMC 0,20 % 500 kHz az 1 MHz 5 µH az 10 µH CMC 0,13 % 1 kHz az 2 kHz 10 µH az 50 µH CMC 2,4 % 2 kHz az 3 kHz 10 µH az 50 µH CMC 1,3 % 3 kHz az 5 kHz 10 µH az 50 µH CMC 0,89 % 5 kHz az 7 kHz 10 µH az 50 µH CMC 0,60 % 7 kHz az 10 kHz 10 µH az 50 µH CMC 0,47 % 10 kHz az 15 kHz 10 µH az 50 µH CMC 0,38 % 15 kHz az 20 kHz 10 µH az 50 µH CMC 0,31 % 20 kHz az 25 kHz 10 µH az 50 µH CMC 0,27 % 25 kHz az 30 kHz 10 µH az 50 µH CMC 0,25 % 30 kHz az 50 kHz 10 µH az 50 µH CMC 0,23 % 50 kHz az 70 kHz 10 µH az 50 µH CMC 0,21 % 70 kHz az 100 kHz 10 µH az 50 µH CMC 0,19 % 100 kHz az 250 kHz 10 µH az 50 µH CMC 0,20 % 250 kHz az 300 kHz 10 µH az 50 µH CMC 0,12 % 300 kHz az 1 MHz 10 µH az 50 µH CMC 0,13 % 200 Hz az 300 Hz 50 µH az 100 µH CMC 2,6 % 300 Hz az 400 Hz 50 µH az 100 µH CMC 1,8 % 400 Hz az 500 Hz 50 µH az 100 µH CMC 1,3 % 500 Hz az 600 Hz 50 µH az 100 µH CMC 1,1 % 600 Hz az 700 Hz 50 µH az 100 µH CMC 0,89 % 700 Hz az 800 Hz 50 µH az 100 µH CMC 0,79 % 800 Hz az 900 Hz 50 µH az 100 µH CMC 0,71 % 900 Hz az 1 kHz 50 µH az 100 µH CMC 0,65 % 1 kHz az 2 kHz 50 µH az 100 µH CMC 0,60 % 2 kHz az 3 kHz 50 µH az 100 µH CMC 0,38 % 3 kHz az 5 kHz 50 µH az 100 µH CMC 0,31 % 5 kHz az 10 kHz 50 µH az 100 µH CMC 0,25 % 10 kHz az 15 kHz 50 µH az 100 µH CMC 0,21 % 15 kHz az 30 kHz 50 µH az 100 µH CMC 0,19 % 30 kHz az 50 kHz 50 µH az 100 µH CMC 0,18 % 50 kHz az 100 kHz 50 µH az 100 µH CMC 0,12 % 100 kHz az 250 kHz 50 µH az 100 µH CMC 0,20 % 250 kHz az 300 kHz 50 µH az 100 µH CMC 0,12 % 300 kHz az 1 MHz 50 µH az 100 µH CMC 0,13 % 80 Hz az 90 Hz 100 µH az 500 µH CMC 6,2 % 90 Hz az 100 Hz 100 µH az 500 µH CMC 5,4 % 100 Hz az 200 Hz 100 µH az 500 µH CMC 2,6 % 200 Hz az 300 Hz 100 µH az 500 µH CMC 1,3 % 300 Hz az 400 Hz 100 µH az 500 µH CMC 0,89 % 400 Hz az 500 Hz 100 µH az 500 µH CMC 0,71 % 500 Hz az 600 Hz 100 µH az 500 µH CMC 0,60 % 600 Hz az 700 Hz 100 µH az 500 µH CMC 0,53 % 700 Hz az 800 Hz 100 µH az 500 µH CMC 0,47 % 800 Hz az 900 Hz 100 µH az 500 µH CMC 0,43 % 900 Hz az 1 kHz 100 µH az 500 µH CMC 0,40 % 1 kHz az 2 kHz 100 µH az 500 µH CMC 0,38 % 2 kHz az 3 kHz 100 µH az 500 µH CMC 0,27 % 3 kHz az 5 kHz 100 µH az 500 µH CMC 0,23 % 5 kHz az 10 kHz 100 µH az 500 µH CMC 0,21 % 10 kHz az 25 kHz 100 µH az 500 µH CMC 0,18 % 25 kHz az 30 kHz 100 µH az 500 µH CMC 0,12 % 30 kHz az 100 kHz 100 µH az 500 µH CMC 0,12 % 100 kHz az 300 kHz 100 µH az 500 µH CMC 0,11 % 300 kHz az 1 MHz 100 µH az 500 µH CMC 0,17 % 50 Hz az 60 Hz 500 µH az 1 mH CMC 2,3 % 60 Hz az 70 Hz 500 µH az 1 mH CMC 1,9 % 70 Hz az 80 Hz 500 µH az 1 mH CMC 1,6 % 80 Hz az 100 Hz 500 µH az 1 mH CMC 1,4 % 100 Hz az 200 Hz 500 µH az 1 mH CMC 0,60 % 200 Hz az 300 Hz 500 µH az 1 mH CMC 0,38 % 300 Hz az 400 Hz 500 µH az 1 mH CMC 0,31 % 400 Hz az 500 Hz 500 µH az 1 mH CMC 0,27 % 500 Hz az 600 Hz 500 µH az 1 mH CMC 0,25 % 600 Hz az 900 Hz 500 µH az 1 mH CMC 0,23 % 900 Hz az 1 kHz 500 µH az 1 mH CMC 0,21 % 1 kHz az 2 kHz 500 µH az 1 mH CMC 0,38 % 2 kHz az 3 kHz 500 µH az 1 mH CMC 0,27 % 3 kHz az 5 kHz 500 µH az 1 mH CMC 0,23 % 5 kHz az 10 kHz 500 µH az 1 mH CMC 0,21 % 10 kHz az 25 kHz 500 µH az 1 mH CMC 0,18 % 25 kHz az 100 kHz 500 µH az 1 mH CMC 0,12 % 100 kHz az 300 kHz 500 µH az 1 mH CMC 0,11 % 300 kHz az 1 MHz 500 µH az 1 mH CMC 0,17 % 20 Hz az 30 Hz 1 mH az 5 mH CMC 3,9 % 30 Hz az 40 Hz 1 mH az 5 mH CMC 2,5 % 40 Hz az 50 Hz 1 mH az 5 mH CMC 1,8 % 50 Hz az 60 Hz 1 mH az 5 mH CMC 1,3 % 60 Hz az 80 Hz 1 mH az 5 mH CMC 1,0 % 80 Hz az 90 Hz 1 mH az 5 mH CMC 0,74 % 90 Hz az 100 Hz 1 mH az 5 mH CMC 0,66 % 100 Hz az 200 Hz 1 mH az 5 mH CMC 0,38 % 200 Hz az 300 Hz 1 mH az 5 mH CMC 0,27 % 300 Hz az 500 Hz 1 mH az 5 mH CMC 0,23 % 500 Hz az 700 Hz 1 mH az 5 mH CMC 0,21 % 700 Hz az 1 kHz 1 mH az 5 mH CMC 0,19 % 1 kHz az 3 kHz 1 mH az 5 mH CMC 0,18 % 3 kHz az 100 kHz 1 mH az 5 mH CMC 0,12 % 100 kHz az 300 kHz 1 mH az 5 mH CMC 0,17 % 300 kHz az 600 kHz 1 mH az 5 mH CMC 0,21 % 600 kHz az 1 MHz 1 mH az 5 mH CMC 0,24 % 20 Hz az 30 Hz 5 mH az 10 mH CMC 1,1 % 30 Hz az 40 Hz 5 mH az 10 mH CMC 0,75 % 40 Hz az 50 Hz 5 mH az 10 mH CMC 0,61 % 50 Hz az 60 Hz 5 mH az 10 mH CMC 0,37 % 60 Hz az 70 Hz 5 mH az 10 mH CMC 0,33 % 70 Hz az 80 Hz 5 mH az 10 mH CMC 0,30 % 80 Hz az 90 Hz 5 mH az 10 mH CMC 0,28 % 90 Hz az 100 Hz 5 mH az 10 mH CMC 0,26 % 100 Hz az 200 Hz 5 mH az 10 mH CMC 0,38 % 200 Hz az 300 Hz 5 mH az 10 mH CMC 0,27 % 300 Hz az 500 Hz 5 mH az 10 mH CMC 0,23 % 500 Hz az 700 Hz 5 mH az 10 mH CMC 0,21 % 700 Hz az 1 kHz 5 mH az 10 mH CMC 0,19 % 1 kHz az 3 kHz 5 mH az 10 mH CMC 0,18 % 3 kHz az 100 kHz 5 mH az 10 mH CMC 0,12 % 100 kHz az 300 kHz 5 mH az 10 mH CMC 0,17 % 300 kHz az 600 kHz 5 mH az 10 mH CMC 0,21 % 600 kHz az 1 MHz 5 mH az 10 mH CMC 0,24 % 20 Hz az 30 Hz 10 mH az 50 mH CMC 0,69 % 30 Hz az 40 Hz 10 mH az 50 mH CMC 0,54 % 40 Hz az 50 Hz 10 mH az 50 mH CMC 0,47 % 50 Hz az 60 Hz 10 mH az 50 mH CMC 0,27 % 60 Hz az 80 Hz 10 mH az 50 mH CMC 0,24 % 80 Hz az 100 Hz 10 mH az 50 mH CMC 0,22 % 100 Hz az 250 Hz 10 mH az 50 mH CMC 0,18 % 250 Hz az 1 kHz 10 mH az 50 mH CMC 0,12 % 1 kHz az 30 kHz 10 mH az 50 mH CMC 0,11 % 30 kHz az 100 kHz 10 mH az 50 mH CMC 0,17 % 100 kHz az 200 kHz 10 mH az 50 mH CMC 0,21 % 200 kHz az 300 kHz 10 mH az 50 mH CMC 0,23 % 300 kHz az 400 kHz 10 mH az 50 mH CMC 0,31 % 400 kHz az 500 kHz 10 mH az 50 mH CMC 0,35 % 500 kHz az 700 kHz 10 mH az 50 mH CMC 0,43 % 700 kHz az 1 MHz 10 mH az 50 mH CMC 0,55 % 20 Hz az 30 Hz 50 mH az 100 mH CMC 0,40 % 30 Hz az 50 Hz 50 mH az 100 mH CMC 0,37 % 50 Hz az 60 Hz 50 mH az 100 mH CMC 0,27 % 60 Hz az 80 Hz 50 mH az 100 mH CMC 0,24 % 80 Hz az 100 Hz 50 mH az 100 mH CMC 0,22 % 100 Hz az 250 Hz 50 mH az 100 mH CMC 0,18 % 250 Hz az 1 kHz 50 mH az 100 mH CMC 0,12 % 1 kHz az 30 kHz 50 mH az 100 mH CMC 0,11 % 30 kHz az 100 kHz 50 mH az 100 mH CMC 0,17 % 100 kHz az 200 kHz 50 mH az 100 mH CMC 0,21 % 200 kHz az 300 kHz 50 mH az 100 mH CMC 0,23 % 300 kHz az 400 kHz 50 mH az 100 mH CMC 0,47 % 400 kHz az 500 kHz 50 mH az 100 mH CMC 0,55 % 500 kHz az 600 kHz 50 mH az 100 mH CMC 0,62 % 600 kHz az 700 kHz 50 mH az 100 mH CMC 0,70 % 700 kHz az 800 kHz 50 mH az 100 mH CMC 0,78 % 800 kHz az 1 MHz 50 mH az 100 mH CMC 0,93 % 20 Hz az 30 Hz 100 mH az 500 mH CMC 0,27 % 30 Hz az 50 Hz 100 mH az 500 mH CMC 0,35 % 50 Hz az 100 Hz 100 mH az 500 mH CMC 0,18 % 100 Hz az 1 kHz 100 mH az 500 mH CMC 0,12 % 1 kHz az 30 kHz 100 mH az 500 mH CMC 0,13 % 30 kHz az 60 kHz 100 mH az 500 mH CMC 0,21 % 60 kHz az 100 kHz 100 mH az 500 mH CMC 0,24 % 100 kHz az 150 kHz 100 mH az 500 mH CMC 0,33 % 150 kHz az 200 kHz 100 mH az 500 mH CMC 0,39 % 200 kHz az 250 kHz 100 mH az 500 mH CMC 0,45 % 250 kHz az 300 kHz 100 mH az 500 mH CMC 0,51 % 300 kHz az 400 kHz 100 mH az 500 mH CMC 1,8 % 400 kHz az 500 kHz 100 mH az 500 mH CMC 2,1 % 500 kHz az 600 kHz 100 mH az 500 mH CMC 2,5 % 600 kHz az 700 kHz 100 mH az 500 mH CMC 2,9 % 700 kHz az 800 kHz 100 mH az 500 mH CMC 3,3 % 800 kHz az 900 kHz 100 mH az 500 mH CMC 3,7 % 900 kHz az 1 MHz 100 mH az 500 mH CMC 4,1 % 20 Hz az 30 Hz 500 mH az 1 H CMC 0,27 % 30 Hz az 50 Hz 500 mH az 1 H CMC 0,35 % 50 Hz az 100 Hz 500 mH az 1 H CMC 0,18 % 100 Hz az 1 kHz 500 mH az 1 H CMC 0,12 % 1 kHz az 30 kHz 500 mH az 1 H CMC 0,13 % 30 kHz az 60 kHz 500 mH az 1 H CMC 0,21 % 60 kHz az 100 kHz 500 mH az 1 H CMC 0,24 % 100 kHz az 150 kHz 500 mH az 1 H CMC 0,51 % 150 kHz az 200 kHz 500 mH az 1 H CMC 0,62 % 200 kHz az 250 kHz 500 mH az 1 H CMC 0,74 % 250 kHz az 300 kHz 500 mH az 1 H CMC 0,86 % 300 kHz az 400 kHz 500 mH az 1 H CMC 3,3 % 400 kHz az 500 kHz 500 mH az 1 H CMC 4,1 % 500 kHz az 600 kHz 500 mH az 1 H CMC 4,9 % 600 kHz az 700 kHz 500 mH az 1 H CMC 5,6 % 700 kHz az 800 kHz 500 mH az 1 H CMC 6,4 % 800 kHz az 900 kHz 500 mH az 1 H CMC 7,2 % 900 kHz az 1 MHz 500 mH az 1 H CMC 8,0 % 20 Hz az 50 Hz 1 H az 2 H CMC 0,34 % 50 Hz az 100 Hz 1 H az 2 H CMC 0,18 % 100 Hz az 1 kHz 1 H az 2 H CMC 0,12 % 1 kHz az 5 kHz 1 H az 2 H CMC 0,15 % 5 kHz az 10 kHz 1 H az 2 H CMC 0,24 % 10 kHz az 15 kHz 1 H az 2 H CMC 0,28 % 15 kHz az 20 kHz 1 H az 2 H CMC 0,31 % 20 kHz az 25 kHz 1 H az 2 H CMC 0,35 % 25 kHz az 30 kHz 1 H az 2 H CMC 0,38 % 30 kHz az 50 kHz 1 H az 2 H CMC 0,35 % 50 kHz az 70 kHz 1 H az 2 H CMC 0,43 % 70 kHz az 100 kHz 1 H az 2 H CMC 0,55 % 100 kHz az 150 kHz 1 H az 2 H CMC 1,9 % 150 kHz az 200 kHz 1 H az 2 H CMC 2,5 % 200 kHz az 250 kHz 1 H az 2 H CMC 3,1 % 250 kHz az 300 kHz 1 H az 2 H CMC 3,7 % 300 kHz az 400 kHz 1 H az 2 H CMC 6,4 % 400 kHz az 500 kHz 1 H az 2 H CMC 8,0 % 20 Hz az 50 Hz 2 H az 5 H CMC 0,34 % 50 Hz az 100 Hz 2 H az 5 H CMC 0,18 % 100 Hz az 1 kHz 2 H az 5 H CMC 0,12 % 1 kHz az 5 kHz 2 H az 5 H CMC 0,15 % 5 kHz az 10 kHz 2 H az 5 H CMC 0,24 % 10 kHz az 15 kHz 2 H az 5 H CMC 0,28 % 15 kHz az 20 kHz 2 H az 5 H CMC 0,31 % 20 kHz az 25 kHz 2 H az 5 H CMC 0,35 % 25 kHz az 30 kHz 2 H az 5 H CMC 0,38 % 30 kHz az 50 kHz 2 H az 5 H CMC 0,35 % 50 kHz az 70 kHz 2 H az 5 H CMC 0,43 % 70 kHz az 100 kHz 2 H az 5 H CMC 0,55 % 100 kHz az 150 kHz 2 H az 5 H CMC 1,9 % 150 kHz az 200 kHz 2 H az 5 H CMC 2,5 % 200 kHz az 250 kHz 2 H az 5 H CMC 3,1 % 250 kHz az 300 kHz 2 H az 5 H CMC 3,7 % 50 Hz az 100 Hz 5 H az 10 H CMC 0,18 % 100 Hz az 1 kHz 5 H az 10 H CMC 0,12 % 1 kHz az 5 kHz 5 H az 10 H CMC 0,15 % 5 kHz az 10 kHz 5 H az 10 H CMC 0,24 % 10 kHz az 15 kHz 5 H az 10 H CMC 0,28 % 15 kHz az 20 kHz 5 H az 10 H CMC 0,31 % 20 kHz az 25 kHz 5 H az 10 H CMC 0,35 % 25 kHz az 30 kHz 5 H az 10 H CMC 0,38 % 30 kHz az 40 kHz 5 H az 10 H CMC 0,47 % 40 kHz az 50 kHz 5 H az 10 H CMC 0,55 % 50 kHz az 60 kHz 5 H az 10 H CMC 0,62 % 60 kHz az 70 kHz 5 H az 10 H CMC 0,70 % 70 kHz az 80 kHz 5 H az 10 H CMC 0,78 % 80 kHz az 90 kHz 5 H az 10 H CMC 0,86 % 90 kHz az 100 kHz 5 H az 10 H CMC 0,93 % 100 kHz az 150 kHz 5 H az 10 H CMC 3,7 % 150 kHz az 200 kHz 5 H az 10 H CMC 4,9 % 200 kHz az 250 kHz 5 H az 10 H CMC 6,0 % 250 kHz az 300 kHz 5 H az 10 H CMC 7,2 % 50 Hz az 100 Hz 10 H az 50 H CMC 0,18 % 100 Hz az 500 Hz 10 H az 50 H CMC 0,15 % 500 Hz az 800 Hz 10 H az 50 H CMC 0,22 % 800 Hz az 2 kHz 10 H az 50 H CMC 0,24 % 2 kHz az 3 kHz 10 H az 50 H CMC 0,28 % 3 kHz az 5 kHz 10 H az 50 H CMC 0,35 % 5 kHz az 7 kHz 10 H az 50 H CMC 0,43 % 7 kHz az 10 kHz 10 H az 50 H CMC 0,55 % 10 kHz az 15 kHz 10 H az 50 H CMC 0,74 % 15 kHz az 20 kHz 10 H az 50 H CMC 0,93 % 20 kHz az 25 kHz 10 H az 50 H CMC 1,2 % 25 kHz az 30 kHz 10 H az 50 H CMC 1,4 % 30 kHz az 40 kHz 10 H az 50 H CMC 1,8 % 40 kHz az 50 kHz 10 H az 50 H CMC 2,1 % 50 kHz az 60 kHz 10 H az 50 H CMC 2,5 % 60 kHz az 70 kHz 10 H az 50 H CMC 2,9 % 70 kHz az 80 kHz 10 H az 50 H CMC 3,3 % 80 kHz az 90 kHz 10 H az 50 H CMC 3,7 % 90 kHz az 100 kHz 10 H az 50 H CMC 4,1 % 50 Hz az 100 Hz 50 H az 100 H CMC 0,18 % 100 Hz az 500 Hz 50 H az 100 H CMC 0,15 % 500 Hz az 800 Hz 50 H az 100 H CMC 0,22 % 800 Hz az 1 kHz 50 H az 100 H CMC 0,24 % 1 kHz az 2 kHz 50 H az 100 H CMC 0,31 % 2 kHz az 3 kHz 50 H az 100 H CMC 0,39 % 3 kHz az 5 kHz 50 H az 100 H CMC 0,55 % 5 kHz az 7 kHz 50 H az 100 H CMC 0,70 % 7 kHz az 10 kHz 50 H az 100 H CMC 0,93 % 10 kHz az 15 kHz 50 H az 100 H CMC 1,4 % 15 kHz az 20 kHz 50 H az 100 H CMC 1,8 % 20 kHz az 25 kHz 50 H az 100 H CMC 2,1 % 25 kHz az 30 kHz 50 H az 100 H CMC 2,5 % 20 Hz az 35 Hz 100 H az 500 H CMC 0,38 % 35 Hz az 50 Hz 100 H az 500 H CMC 0,40 % 50 Hz az 70 Hz 100 H az 500 H CMC 0,28 % 70 Hz az 200 Hz 100 H az 500 H CMC 0,31 % 200 Hz az 300 Hz 100 H az 500 H CMC 0,39 % 300 Hz az 400 Hz 100 H az 500 H CMC 0,47 % 400 Hz az 500 Hz 100 H az 500 H CMC 0,55 % 500 Hz az 600 Hz 100 H az 500 H CMC 0,62 % 600 Hz az 700 Hz 100 H az 500 H CMC 0,70 % 700 Hz az 800 Hz 100 H az 500 H CMC 0,78 % 800 Hz az 900 Hz 100 H az 500 H CMC 0,86 % 900 Hz az 2 kHz 100 H az 500 H CMC 0,93 % 2 kHz az 3 kHz 100 H az 500 H CMC 1,4 % 3 kHz az 5 kHz 100 H az 500 H CMC 2,1 % 5 kHz az 7 kHz 100 H az 500 H CMC 2,9 % 7 kHz az 8 kHz 100 H az 500 H CMC 3,3 % 8 kHz az 9 kHz 100 H az 500 H CMC 3,7 % 9 kHz az 10 kHz 100 H az 500 H CMC 4,1 % 20 Hz az 35 Hz 500 H az 1 kH CMC 0,38 % 35 Hz az 50 Hz 500 H az 1 kH CMC 0,40 % 50 Hz az 70 Hz 500 H az 1 kH CMC 0,28 % 70 Hz az 100 Hz 500 H az 1 kH CMC 0,31 % 100 Hz az 200 Hz 500 H az 1 kH CMC 0,31 % 200 Hz az 300 Hz 500 H az 1 kH CMC 0,39 % 300 Hz az 400 Hz 500 H az 1 kH CMC 0,47 % 400 Hz az 500 Hz 500 H az 1 kH CMC 0,55 % 500 Hz az 600 Hz 500 H az 1 kH CMC 0,62 % 600 Hz az 700 Hz 500 H az 1 kH CMC 0,70 % 700 Hz az 800 Hz 500 H az 1 kH CMC 0,78 % 800 Hz az 900 Hz 500 H az 1 kH CMC 0,86 % 900 Hz az 1 kHz 500 H az 1 kH CMC 0,93 % TP8, TP24","search_en":"Inductance / Inductance standards Calibration – electrical quantities Direct measurement by a RLC meter 10 kHz to 15 kHz 1 µH to 5 µH CMC 2,4 % 15 kHz to 20 kHz 1 µH to 5 µH CMC 1,7 % 20 kHz to 25 kHz 1 µH to 5 µH CMC 1,3 % 25 kHz to 30 kHz 1 µH to 5 µH CMC 1,1 % 30 kHz to 40 kHz 1 µH to 5 µH CMC 0,89 % 40 kHz to 50 kHz 1 µH to 5 µH CMC 0,71 % 50 kHz to 60 kHz 1 µH to 5 µH CMC 0,60 % 60 kHz to 70 kHz 1 µH to 5 µH CMC 0,53 % 70 kHz to 80 kHz 1 µH to 5 µH CMC 0,47 % 80 kHz to 90 kHz 1 µH to 5 µH CMC 0,43 % 90 kHz to 100 kHz 1 µH to 5 µH CMC 0,40 % 100 kHz to 150 kHz 1 µH to 5 µH CMC 0,56 % 150 kHz to 200 kHz 1 µH to 5 µH CMC 0,45 % 200 kHz to 250 kHz 1 µH to 5 µH CMC 0,36 % 250 kHz to 300 kHz 1 µH to 5 µH CMC 0,32 % 300 kHz to 400 kHz 1 µH to 5 µH CMC 0,36 % 400 kHz to 500 kHz 1 µH to 5 µH CMC 0,31 % 500 kHz to 700 kHz 1 µH to 5 µH CMC 0,28 % 700 kHz to 1 MHz 1 µH to 5 µH CMC 0,24 % 2 kHz to 3 kHz 5 µH to 10 µH CMC 2,4 % 3 kHz to 5 kHz 5 µH to 10 µH CMC 1,7 % 5 kHz to 7 kHz 5 µH to 10 µH CMC 1,1 % 7 kHz to 10 kHz 5 µH to 10 µH CMC 0,79 % 10 kHz to 15 kHz 5 µH to 10 µH CMC 0,60 % 15 kHz to 20 kHz 5 µH to 10 µH CMC 0,45 % 20 kHz to 25 kHz 5 µH to 10 µH CMC 0,38 % 25 kHz to 30 kHz 5 µH to 10 µH CMC 0,34 % 30 kHz to 40 kHz 5 µH to 10 µH CMC 0,31 % 40 kHz to 50 kHz 5 µH to 10 µH CMC 0,27 % 50 kHz to 60 kHz 5 µH to 10 µH CMC 0,25 % 60 kHz to 100 kHz 5 µH to 10 µH CMC 0,23 % 100 kHz to 150 kHz 5 µH to 10 µH CMC 0,24 % 150 kHz to 200 kHz 5 µH to 10 µH CMC 0,22 % 200 kHz to 500 kHz 5 µH to 10 µH CMC 0,20 % 500 kHz to 1 MHz 5 µH to 10 µH CMC 0,13 % 1 kHz to 2 kHz 10 µH to 50 µH CMC 2,4 % 2 kHz to 3 kHz 10 µH to 50 µH CMC 1,3 % 3 kHz to 5 kHz 10 µH to 50 µH CMC 0,89 % 5 kHz to 7 kHz 10 µH to 50 µH CMC 0,60 % 7 kHz to 10 kHz 10 µH to 50 µH CMC 0,47 % 10 kHz to 15 kHz 10 µH to 50 µH CMC 0,38 % 15 kHz to 20 kHz 10 µH to 50 µH CMC 0,31 % 20 kHz to 25 kHz 10 µH to 50 µH CMC 0,27 % 25 kHz to 30 kHz 10 µH to 50 µH CMC 0,25 % 30 kHz to 50 kHz 10 µH to 50 µH CMC 0,23 % 50 kHz to 70 kHz 10 µH to 50 µH CMC 0,21 % 70 kHz to 100 kHz 10 µH to 50 µH CMC 0,19 % 100 kHz to 250 kHz 10 µH to 50 µH CMC 0,20 % 250 kHz to 300 kHz 10 µH to 50 µH CMC 0,12 % 300 kHz to 1 MHz 10 µH to 50 µH CMC 0,13 % 200 Hz to 300 Hz 50 µH to 100 µH CMC 2,6 % 300 Hz to 400 Hz 50 µH to 100 µH CMC 1,8 % 400 Hz to 500 Hz 50 µH to 100 µH CMC 1,3 % 500 Hz to 600 Hz 50 µH to 100 µH CMC 1,1 % 600 Hz to 700 Hz 50 µH to 100 µH CMC 0,89 % 700 Hz to 800 Hz 50 µH to 100 µH CMC 0,79 % 800 Hz to 900 Hz 50 µH to 100 µH CMC 0,71 % 900 Hz to 1 kHz 50 µH to 100 µH CMC 0,65 % 1 kHz to 2 kHz 50 µH to 100 µH CMC 0,60 % 2 kHz to 3 kHz 50 µH to 100 µH CMC 0,38 % 3 kHz to 5 kHz 50 µH to 100 µH CMC 0,31 % 5 kHz to 10 kHz 50 µH to 100 µH CMC 0,25 % 10 kHz to 15 kHz 50 µH to 100 µH CMC 0,21 % 15 kHz to 30 kHz 50 µH to 100 µH CMC 0,19 % 30 kHz to 50 kHz 50 µH to 100 µH CMC 0,18 % 50 kHz to 100 kHz 50 µH to 100 µH CMC 0,12 % 100 kHz to 250 kHz 50 µH to 100 µH CMC 0,20 % 250 kHz to 300 kHz 50 µH to 100 µH CMC 0,12 % 300 kHz to 1 MHz 50 µH to 100 µH CMC 0,13 % 80 Hz to 90 Hz 100 µH to 500 µH CMC 6,2 % 90 Hz to 100 Hz 100 µH to 500 µH CMC 5,4 % 100 Hz to 200 Hz 100 µH to 500 µH CMC 2,6 % 200 Hz to 300 Hz 100 µH to 500 µH CMC 1,3 % 300 Hz to 400 Hz 100 µH to 500 µH CMC 0,89 % 400 Hz to 500 Hz 100 µH to 500 µH CMC 0,71 % 500 Hz to 600 Hz 100 µH to 500 µH CMC 0,60 % 600 Hz to 700 Hz 100 µH to 500 µH CMC 0,53 % 700 Hz to 800 Hz 100 µH to 500 µH CMC 0,47 % 800 Hz to 900 Hz 100 µH to 500 µH CMC 0,43 % 900 Hz to 1 kHz 100 µH to 500 µH CMC 0,40 % 1 kHz to 2 kHz 100 µH to 500 µH CMC 0,38 % 2 kHz to 3 kHz 100 µH to 500 µH CMC 0,27 % 3 kHz to 5 kHz 100 µH to 500 µH CMC 0,23 % 5 kHz to 10 kHz 100 µH to 500 µH CMC 0,21 % 10 kHz to 25 kHz 100 µH to 500 µH CMC 0,18 % 25 kHz to 30 kHz 100 µH to 500 µH CMC 0,12 % 30 kHz to 100 kHz 100 µH to 500 µH CMC 0,12 % 100 kHz to 300 kHz 100 µH to 500 µH CMC 0,11 % 300 kHz to 1 MHz 100 µH to 500 µH CMC 0,17 % 50 Hz to 60 Hz 500 µH to 1 mH CMC 2,3 % 60 Hz to 70 Hz 500 µH to 1 mH CMC 1,9 % 70 Hz to 80 Hz 500 µH to 1 mH CMC 1,6 % 80 Hz to 100 Hz 500 µH to 1 mH CMC 1,4 % 100 Hz to 200 Hz 500 µH to 1 mH CMC 0,60 % 200 Hz to 300 Hz 500 µH to 1 mH CMC 0,38 % 300 Hz to 400 Hz 500 µH to 1 mH CMC 0,31 % 400 Hz to 500 Hz 500 µH to 1 mH CMC 0,27 % 500 Hz to 600 Hz 500 µH to 1 mH CMC 0,25 % 600 Hz to 900 Hz 500 µH to 1 mH CMC 0,23 % 900 Hz to 1 kHz 500 µH to 1 mH CMC 0,21 % 1 kHz to 2 kHz 500 µH to 1 mH CMC 0,38 % 2 kHz to 3 kHz 500 µH to 1 mH CMC 0,27 % 3 kHz to 5 kHz 500 µH to 1 mH CMC 0,23 % 5 kHz to 10 kHz 500 µH to 1 mH CMC 0,21 % 10 kHz to 25 kHz 500 µH to 1 mH CMC 0,18 % 25 kHz to 100 kHz 500 µH to 1 mH CMC 0,12 % 100 kHz to 300 kHz 500 µH to 1 mH CMC 0,11 % 300 kHz to 1 MHz 500 µH to 1 mH CMC 0,17 % 20 Hz to 30 Hz 1 mH to 5 mH CMC 3,9 % 30 Hz to 40 Hz 1 mH to 5 mH CMC 2,5 % 40 Hz to 50 Hz 1 mH to 5 mH CMC 1,8 % 50 Hz to 60 Hz 1 mH to 5 mH CMC 1,3 % 60 Hz to 80 Hz 1 mH to 5 mH CMC 1,0 % 80 Hz to 90 Hz 1 mH to 5 mH CMC 0,74 % 90 Hz to 100 Hz 1 mH to 5 mH CMC 0,66 % 100 Hz to 200 Hz 1 mH to 5 mH CMC 0,38 % 200 Hz to 300 Hz 1 mH to 5 mH CMC 0,27 % 300 Hz to 500 Hz 1 mH to 5 mH CMC 0,23 % 500 Hz to 700 Hz 1 mH to 5 mH CMC 0,21 % 700 Hz to 1 kHz 1 mH to 5 mH CMC 0,19 % 1 kHz to 3 kHz 1 mH to 5 mH CMC 0,18 % 3 kHz to 100 kHz 1 mH to 5 mH CMC 0,12 % 100 kHz to 300 kHz 1 mH to 5 mH CMC 0,17 % 300 kHz to 600 kHz 1 mH to 5 mH CMC 0,21 % 600 kHz to 1 MHz 1 mH to 5 mH CMC 0,24 % 20 Hz to 30 Hz 5 mH to 10 mH CMC 1,1 % 30 Hz to 40 Hz 5 mH to 10 mH CMC 0,75 % 40 Hz to 50 Hz 5 mH to 10 mH CMC 0,61 % 50 Hz to 60 Hz 5 mH to 10 mH CMC 0,37 % 60 Hz to 70 Hz 5 mH to 10 mH CMC 0,33 % 70 Hz to 80 Hz 5 mH to 10 mH CMC 0,30 % 80 Hz to 90 Hz 5 mH to 10 mH CMC 0,28 % 90 Hz to 100 Hz 5 mH to 10 mH CMC 0,26 % 100 Hz to 200 Hz 5 mH to 10 mH CMC 0,38 % 200 Hz to 300 Hz 5 mH to 10 mH CMC 0,27 % 300 Hz to 500 Hz 5 mH to 10 mH CMC 0,23 % 500 Hz to 700 Hz 5 mH to 10 mH CMC 0,21 % 700 Hz to 1 kHz 5 mH to 10 mH CMC 0,19 % 1 kHz to 3 kHz 5 mH to 10 mH CMC 0,18 % 3 kHz to 100 kHz 5 mH to 10 mH CMC 0,12 % 100 kHz to 300 kHz 5 mH to 10 mH CMC 0,17 % 300 kHz to 600 kHz 5 mH to 10 mH CMC 0,21 % 600 kHz to 1 MHz 5 mH to 10 mH CMC 0,24 % 20 Hz to 30 Hz 10 mH to 50 mH CMC 0,69 % 30 Hz to 40 Hz 10 mH to 50 mH CMC 0,54 % 40 Hz to 50 Hz 10 mH to 50 mH CMC 0,47 % 50 Hz to 60 Hz 10 mH to 50 mH CMC 0,27 % 60 Hz to 80 Hz 10 mH to 50 mH CMC 0,24 % 80 Hz to 100 Hz 10 mH to 50 mH CMC 0,22 % 100 Hz to 250 Hz 10 mH to 50 mH CMC 0,18 % 250 Hz to 1 kHz 10 mH to 50 mH CMC 0,12 % 1 kHz to 30 kHz 10 mH to 50 mH CMC 0,11 % 30 kHz to 100 kHz 10 mH to 50 mH CMC 0,17 % 100 kHz to 200 kHz 10 mH to 50 mH CMC 0,21 % 200 kHz to 300 kHz 10 mH to 50 mH CMC 0,23 % 300 kHz to 400 kHz 10 mH to 50 mH CMC 0,31 % 400 kHz to 500 kHz 10 mH to 50 mH CMC 0,35 % 500 kHz to 700 kHz 10 mH to 50 mH CMC 0,43 % 700 kHz to 1 MHz 10 mH to 50 mH CMC 0,55 % 20 Hz to 30 Hz 50 mH to 100 mH CMC 0,40 % 30 Hz to 50 Hz 50 mH to 100 mH CMC 0,37 % 50 Hz to 60 Hz 50 mH to 100 mH CMC 0,27 % 60 Hz to 80 Hz 50 mH to 100 mH CMC 0,24 % 80 Hz to 100 Hz 50 mH to 100 mH CMC 0,22 % 100 Hz to 250 Hz 50 mH to 100 mH CMC 0,18 % 250 Hz to 1 kHz 50 mH to 100 mH CMC 0,12 % 1 kHz to 30 kHz 50 mH to 100 mH CMC 0,11 % 30 kHz to 100 kHz 50 mH to 100 mH CMC 0,17 % 100 kHz to 200 kHz 50 mH to 100 mH CMC 0,21 % 200 kHz to 300 kHz 50 mH to 100 mH CMC 0,23 % 300 kHz to 400 kHz 50 mH to 100 mH CMC 0,47 % 400 kHz to 500 kHz 50 mH to 100 mH CMC 0,55 % 500 kHz to 600 kHz 50 mH to 100 mH CMC 0,62 % 600 kHz to 700 kHz 50 mH to 100 mH CMC 0,70 % 700 kHz to 800 kHz 50 mH to 100 mH CMC 0,78 % 800 kHz to 1 MHz 50 mH to 100 mH CMC 0,93 % 20 Hz to 30 Hz 100 mH to 500 mH CMC 0,27 % 30 Hz to 50 Hz 100 mH to 500 mH CMC 0,35 % 50 Hz to 100 Hz 100 mH to 500 mH CMC 0,18 % 100 Hz to 1 kHz 100 mH to 500 mH CMC 0,12 % 1 kHz to 30 kHz 100 mH to 500 mH CMC 0,13 % 30 kHz to 60 kHz 100 mH to 500 mH CMC 0,21 % 60 kHz to 100 kHz 100 mH to 500 mH CMC 0,24 % 100 kHz to 150 kHz 100 mH to 500 mH CMC 0,33 % 150 kHz to 200 kHz 100 mH to 500 mH CMC 0,39 % 200 kHz to 250 kHz 100 mH to 500 mH CMC 0,45 % 250 kHz to 300 kHz 100 mH to 500 mH CMC 0,51 % 300 kHz to 400 kHz 100 mH to 500 mH CMC 1,8 % 400 kHz to 500 kHz 100 mH to 500 mH CMC 2,1 % 500 kHz to 600 kHz 100 mH to 500 mH CMC 2,5 % 600 kHz to 700 kHz 100 mH to 500 mH CMC 2,9 % 700 kHz to 800 kHz 100 mH to 500 mH CMC 3,3 % 800 kHz to 900 kHz 100 mH to 500 mH CMC 3,7 % 900 kHz to 1 MHz 100 mH to 500 mH CMC 4,1 % 20 Hz to 30 Hz 500 mH to 1 H CMC 0,27 % 30 Hz to 50 Hz 500 mH to 1 H CMC 0,35 % 50 Hz to 100 Hz 500 mH to 1 H CMC 0,18 % 100 Hz to 1 kHz 500 mH to 1 H CMC 0,12 % 1 kHz to 30 kHz 500 mH to 1 H CMC 0,13 % 30 kHz to 60 kHz 500 mH to 1 H CMC 0,21 % 60 kHz to 100 kHz 500 mH to 1 H CMC 0,24 % 100 kHz to 150 kHz 500 mH to 1 H CMC 0,51 % 150 kHz to 200 kHz 500 mH to 1 H CMC 0,62 % 200 kHz to 250 kHz 500 mH to 1 H CMC 0,74 % 250 kHz to 300 kHz 500 mH to 1 H CMC 0,86 % 300 kHz to 400 kHz 500 mH to 1 H CMC 3,3 % 400 kHz to 500 kHz 500 mH to 1 H CMC 4,1 % 500 kHz to 600 kHz 500 mH to 1 H CMC 4,9 % 600 kHz to 700 kHz 500 mH to 1 H CMC 5,6 % 700 kHz to 800 kHz 500 mH to 1 H CMC 6,4 % 800 kHz to 900 kHz 500 mH to 1 H CMC 7,2 % 900 kHz to 1 MHz 500 mH to 1 H CMC 8,0 % 20 Hz to 50 Hz 1 H to 2 H CMC 0,34 % 50 Hz to 100 Hz 1 H to 2 H CMC 0,18 % 100 Hz to 1 kHz 1 H to 2 H CMC 0,12 % 1 kHz to 5 kHz 1 H to 2 H CMC 0,15 % 5 kHz to 10 kHz 1 H to 2 H CMC 0,24 % 10 kHz to 15 kHz 1 H to 2 H CMC 0,28 % 15 kHz to 20 kHz 1 H to 2 H CMC 0,31 % 20 kHz to 25 kHz 1 H to 2 H CMC 0,35 % 25 kHz to 30 kHz 1 H to 2 H CMC 0,38 % 30 kHz to 50 kHz 1 H to 2 H CMC 0,35 % 50 kHz to 70 kHz 1 H to 2 H CMC 0,43 % 70 kHz to 100 kHz 1 H to 2 H CMC 0,55 % 100 kHz to 150 kHz 1 H to 2 H CMC 1,9 % 150 kHz to 200 kHz 1 H to 2 H CMC 2,5 % 200 kHz to 250 kHz 1 H to 2 H CMC 3,1 % 250 kHz to 300 kHz 1 H to 2 H CMC 3,7 % 300 kHz to 400 kHz 1 H to 2 H CMC 6,4 % 400 kHz to 500 kHz 1 H to 2 H CMC 8,0 % 20 Hz to 50 Hz 2 H to 5 H CMC 0,34 % 50 Hz to 100 Hz 2 H to 5 H CMC 0,18 % 100 Hz to 1 kHz 2 H to 5 H CMC 0,12 % 1 kHz to 5 kHz 2 H to 5 H CMC 0,15 % 5 kHz to 10 kHz 2 H to 5 H CMC 0,24 % 10 kHz to 15 kHz 2 H to 5 H CMC 0,28 % 15 kHz to 20 kHz 2 H to 5 H CMC 0,31 % 20 kHz to 25 kHz 2 H to 5 H CMC 0,35 % 25 kHz to 30 kHz 2 H to 5 H CMC 0,38 % 30 kHz to 50 kHz 2 H to 5 H CMC 0,35 % 50 kHz to 70 kHz 2 H to 5 H CMC 0,43 % 70 kHz to 100 kHz 2 H to 5 H CMC 0,55 % 100 kHz to 150 kHz 2 H to 5 H CMC 1,9 % 150 kHz to 200 kHz 2 H to 5 H CMC 2,5 % 200 kHz to 250 kHz 2 H to 5 H CMC 3,1 % 250 kHz to 300 kHz 2 H to 5 H CMC 3,7 % 50 Hz to 100 Hz 5 H to 10 H CMC 0,18 % 100 Hz to 1 kHz 5 H to 10 H CMC 0,12 % 1 kHz to 5 kHz 5 H to 10 H CMC 0,15 % 5 kHz to 10 kHz 5 H to 10 H CMC 0,24 % 10 kHz to 15 kHz 5 H to 10 H CMC 0,28 % 15 kHz to 20 kHz 5 H to 10 H CMC 0,31 % 20 kHz to 25 kHz 5 H to 10 H CMC 0,35 % 25 kHz to 30 kHz 5 H to 10 H CMC 0,38 % 30 kHz to 40 kHz 5 H to 10 H CMC 0,47 % 40 kHz to 50 kHz 5 H to 10 H CMC 0,55 % 50 kHz to 60 kHz 5 H to 10 H CMC 0,62 % 60 kHz to 70 kHz 5 H to 10 H CMC 0,70 % 70 kHz to 80 kHz 5 H to 10 H CMC 0,78 % 80 kHz to 90 kHz 5 H to 10 H CMC 0,86 % 90 kHz to 100 kHz 5 H to 10 H CMC 0,93 % 100 kHz to 150 kHz 5 H to 10 H CMC 3,7 % 150 kHz to 200 kHz 5 H to 10 H CMC 4,9 % 200 kHz to 250 kHz 5 H to 10 H CMC 6,0 % 250 kHz to 300 kHz 5 H to 10 H CMC 7,2 % 50 Hz to 100 Hz 10 H to 50 H CMC 0,18 % 100 Hz to 500 Hz 10 H to 50 H CMC 0,15 % 500 Hz to 800 Hz 10 H to 50 H CMC 0,22 % 800 Hz to 2 kHz 10 H to 50 H CMC 0,24 % 2 kHz to 3 kHz 10 H to 50 H CMC 0,28 % 3 kHz to 5 kHz 10 H to 50 H CMC 0,35 % 5 kHz to 7 kHz 10 H to 50 H CMC 0,43 % 7 kHz to 10 kHz 10 H to 50 H CMC 0,55 % 10 kHz to 15 kHz 10 H to 50 H CMC 0,74 % 15 kHz to 20 kHz 10 H to 50 H CMC 0,93 % 20 kHz to 25 kHz 10 H to 50 H CMC 1,2 % 25 kHz to 30 kHz 10 H to 50 H CMC 1,4 % 30 kHz to 40 kHz 10 H to 50 H CMC 1,8 % 40 kHz to 50 kHz 10 H to 50 H CMC 2,1 % 50 kHz to 60 kHz 10 H to 50 H CMC 2,5 % 60 kHz to 70 kHz 10 H to 50 H CMC 2,9 % 70 kHz to 80 kHz 10 H to 50 H CMC 3,3 % 80 kHz to 90 kHz 10 H to 50 H CMC 3,7 % 90 kHz to 100 kHz 10 H to 50 H CMC 4,1 % 50 Hz to 100 Hz 50 H to 100 H CMC 0,18 % 100 Hz to 500 Hz 50 H to 100 H CMC 0,15 % 500 Hz to 800 Hz 50 H to 100 H CMC 0,22 % 800 Hz to 1 kHz 50 H to 100 H CMC 0,24 % 1 kHz to 2 kHz 50 H to 100 H CMC 0,31 % 2 kHz to 3 kHz 50 H to 100 H CMC 0,39 % 3 kHz to 5 kHz 50 H to 100 H CMC 0,55 % 5 kHz to 7 kHz 50 H to 100 H CMC 0,70 % 7 kHz to 10 kHz 50 H to 100 H CMC 0,93 % 10 kHz to 15 kHz 50 H to 100 H CMC 1,4 % 15 kHz to 20 kHz 50 H to 100 H CMC 1,8 % 20 kHz to 25 kHz 50 H to 100 H CMC 2,1 % 25 kHz to 30 kHz 50 H to 100 H CMC 2,5 % 20 Hz to 35 Hz 100 H to 500 H CMC 0,38 % 35 Hz to 50 Hz 100 H to 500 H CMC 0,40 % 50 Hz to 70 Hz 100 H to 500 H CMC 0,28 % 70 Hz to 200 Hz 100 H to 500 H CMC 0,31 % 200 Hz to 300 Hz 100 H to 500 H CMC 0,39 % 300 Hz to 400 Hz 100 H to 500 H CMC 0,47 % 400 Hz to 500 Hz 100 H to 500 H CMC 0,55 % 500 Hz to 600 Hz 100 H to 500 H CMC 0,62 % 600 Hz to 700 Hz 100 H to 500 H CMC 0,70 % 700 Hz to 800 Hz 100 H to 500 H CMC 0,78 % 800 Hz to 900 Hz 100 H to 500 H CMC 0,86 % 900 Hz to 2 kHz 100 H to 500 H CMC 0,93 % 2 kHz to 3 kHz 100 H to 500 H CMC 1,4 % 3 kHz to 5 kHz 100 H to 500 H CMC 2,1 % 5 kHz to 7 kHz 100 H to 500 H CMC 2,9 % 7 kHz to 8 kHz 100 H to 500 H CMC 3,3 % 8 kHz to 9 kHz 100 H to 500 H CMC 3,7 % 9 kHz to 10 kHz 100 H to 500 H CMC 4,1 % 20 Hz to 35 Hz 500 H to 1 kH CMC 0,38 % 35 Hz to 50 Hz 500 H to 1 kH CMC 0,40 % 50 Hz to 70 Hz 500 H to 1 kH CMC 0,28 % 70 Hz to 100 Hz 500 H to 1 kH CMC 0,31 % 100 Hz to 200 Hz 500 H to 1 kH CMC 0,31 % 200 Hz to 300 Hz 500 H to 1 kH CMC 0,39 % 300 Hz to 400 Hz 500 H to 1 kH CMC 0,47 % 400 Hz to 500 Hz 500 H to 1 kH CMC 0,55 % 500 Hz to 600 Hz 500 H to 1 kH CMC 0,62 % 600 Hz to 700 Hz 500 H to 1 kH CMC 0,70 % 700 Hz to 800 Hz 500 H to 1 kH CMC 0,78 % 800 Hz to 900 Hz 500 H to 1 kH CMC 0,86 % 900 Hz to 1 kHz 500 H to 1 kH CMC 0,93 % TP8, TP24","search_zh":"电感 / 电感标准器 校准 – 电学量 用 RLC 表直接测量 10 kHz 至 15 kHz 1 µH 至 5 µH CMC 2,4 % 15 kHz 至 20 kHz 1 µH 至 5 µH CMC 1,7 % 20 kHz 至 25 kHz 1 µH 至 5 µH CMC 1,3 % 25 kHz 至 30 kHz 1 µH 至 5 µH CMC 1,1 % 30 kHz 至 40 kHz 1 µH 至 5 µH CMC 0,89 % 40 kHz 至 50 kHz 1 µH 至 5 µH CMC 0,71 % 50 kHz 至 60 kHz 1 µH 至 5 µH CMC 0,60 % 60 kHz 至 70 kHz 1 µH 至 5 µH CMC 0,53 % 70 kHz 至 80 kHz 1 µH 至 5 µH CMC 0,47 % 80 kHz 至 90 kHz 1 µH 至 5 µH CMC 0,43 % 90 kHz 至 100 kHz 1 µH 至 5 µH CMC 0,40 % 100 kHz 至 150 kHz 1 µH 至 5 µH CMC 0,56 % 150 kHz 至 200 kHz 1 µH 至 5 µH CMC 0,45 % 200 kHz 至 250 kHz 1 µH 至 5 µH CMC 0,36 % 250 kHz 至 300 kHz 1 µH 至 5 µH CMC 0,32 % 300 kHz 至 400 kHz 1 µH 至 5 µH CMC 0,36 % 400 kHz 至 500 kHz 1 µH 至 5 µH CMC 0,31 % 500 kHz 至 700 kHz 1 µH 至 5 µH CMC 0,28 % 700 kHz 至 1 MHz 1 µH 至 5 µH CMC 0,24 % 2 kHz 至 3 kHz 5 µH 至 10 µH CMC 2,4 % 3 kHz 至 5 kHz 5 µH 至 10 µH CMC 1,7 % 5 kHz 至 7 kHz 5 µH 至 10 µH CMC 1,1 % 7 kHz 至 10 kHz 5 µH 至 10 µH CMC 0,79 % 10 kHz 至 15 kHz 5 µH 至 10 µH CMC 0,60 % 15 kHz 至 20 kHz 5 µH 至 10 µH CMC 0,45 % 20 kHz 至 25 kHz 5 µH 至 10 µH CMC 0,38 % 25 kHz 至 30 kHz 5 µH 至 10 µH CMC 0,34 % 30 kHz 至 40 kHz 5 µH 至 10 µH CMC 0,31 % 40 kHz 至 50 kHz 5 µH 至 10 µH CMC 0,27 % 50 kHz 至 60 kHz 5 µH 至 10 µH CMC 0,25 % 60 kHz 至 100 kHz 5 µH 至 10 µH CMC 0,23 % 100 kHz 至 150 kHz 5 µH 至 10 µH CMC 0,24 % 150 kHz 至 200 kHz 5 µH 至 10 µH CMC 0,22 % 200 kHz 至 500 kHz 5 µH 至 10 µH CMC 0,20 % 500 kHz 至 1 MHz 5 µH 至 10 µH CMC 0,13 % 1 kHz 至 2 kHz 10 µH 至 50 µH CMC 2,4 % 2 kHz 至 3 kHz 10 µH 至 50 µH CMC 1,3 % 3 kHz 至 5 kHz 10 µH 至 50 µH CMC 0,89 % 5 kHz 至 7 kHz 10 µH 至 50 µH CMC 0,60 % 7 kHz 至 10 kHz 10 µH 至 50 µH CMC 0,47 % 10 kHz 至 15 kHz 10 µH 至 50 µH CMC 0,38 % 15 kHz 至 20 kHz 10 µH 至 50 µH CMC 0,31 % 20 kHz 至 25 kHz 10 µH 至 50 µH CMC 0,27 % 25 kHz 至 30 kHz 10 µH 至 50 µH CMC 0,25 % 30 kHz 至 50 kHz 10 µH 至 50 µH CMC 0,23 % 50 kHz 至 70 kHz 10 µH 至 50 µH CMC 0,21 % 70 kHz 至 100 kHz 10 µH 至 50 µH CMC 0,19 % 100 kHz 至 250 kHz 10 µH 至 50 µH CMC 0,20 % 250 kHz 至 300 kHz 10 µH 至 50 µH CMC 0,12 % 300 kHz 至 1 MHz 10 µH 至 50 µH CMC 0,13 % 200 Hz 至 300 Hz 50 µH 至 100 µH CMC 2,6 % 300 Hz 至 400 Hz 50 µH 至 100 µH CMC 1,8 % 400 Hz 至 500 Hz 50 µH 至 100 µH CMC 1,3 % 500 Hz 至 600 Hz 50 µH 至 100 µH CMC 1,1 % 600 Hz 至 700 Hz 50 µH 至 100 µH CMC 0,89 % 700 Hz 至 800 Hz 50 µH 至 100 µH CMC 0,79 % 800 Hz 至 900 Hz 50 µH 至 100 µH CMC 0,71 % 900 Hz 至 1 kHz 50 µH 至 100 µH CMC 0,65 % 1 kHz 至 2 kHz 50 µH 至 100 µH CMC 0,60 % 2 kHz 至 3 kHz 50 µH 至 100 µH CMC 0,38 % 3 kHz 至 5 kHz 50 µH 至 100 µH CMC 0,31 % 5 kHz 至 10 kHz 50 µH 至 100 µH CMC 0,25 % 10 kHz 至 15 kHz 50 µH 至 100 µH CMC 0,21 % 15 kHz 至 30 kHz 50 µH 至 100 µH CMC 0,19 % 30 kHz 至 50 kHz 50 µH 至 100 µH CMC 0,18 % 50 kHz 至 100 kHz 50 µH 至 100 µH CMC 0,12 % 100 kHz 至 250 kHz 50 µH 至 100 µH CMC 0,20 % 250 kHz 至 300 kHz 50 µH 至 100 µH CMC 0,12 % 300 kHz 至 1 MHz 50 µH 至 100 µH CMC 0,13 % 80 Hz 至 90 Hz 100 µH 至 500 µH CMC 6,2 % 90 Hz 至 100 Hz 100 µH 至 500 µH CMC 5,4 % 100 Hz 至 200 Hz 100 µH 至 500 µH CMC 2,6 % 200 Hz 至 300 Hz 100 µH 至 500 µH CMC 1,3 % 300 Hz 至 400 Hz 100 µH 至 500 µH CMC 0,89 % 400 Hz 至 500 Hz 100 µH 至 500 µH CMC 0,71 % 500 Hz 至 600 Hz 100 µH 至 500 µH CMC 0,60 % 600 Hz 至 700 Hz 100 µH 至 500 µH CMC 0,53 % 700 Hz 至 800 Hz 100 µH 至 500 µH CMC 0,47 % 800 Hz 至 900 Hz 100 µH 至 500 µH CMC 0,43 % 900 Hz 至 1 kHz 100 µH 至 500 µH CMC 0,40 % 1 kHz 至 2 kHz 100 µH 至 500 µH CMC 0,38 % 2 kHz 至 3 kHz 100 µH 至 500 µH CMC 0,27 % 3 kHz 至 5 kHz 100 µH 至 500 µH CMC 0,23 % 5 kHz 至 10 kHz 100 µH 至 500 µH CMC 0,21 % 10 kHz 至 25 kHz 100 µH 至 500 µH CMC 0,18 % 25 kHz 至 30 kHz 100 µH 至 500 µH CMC 0,12 % 30 kHz 至 100 kHz 100 µH 至 500 µH CMC 0,12 % 100 kHz 至 300 kHz 100 µH 至 500 µH CMC 0,11 % 300 kHz 至 1 MHz 100 µH 至 500 µH CMC 0,17 % 50 Hz 至 60 Hz 500 µH 至 1 mH CMC 2,3 % 60 Hz 至 70 Hz 500 µH 至 1 mH CMC 1,9 % 70 Hz 至 80 Hz 500 µH 至 1 mH CMC 1,6 % 80 Hz 至 100 Hz 500 µH 至 1 mH CMC 1,4 % 100 Hz 至 200 Hz 500 µH 至 1 mH CMC 0,60 % 200 Hz 至 300 Hz 500 µH 至 1 mH CMC 0,38 % 300 Hz 至 400 Hz 500 µH 至 1 mH CMC 0,31 % 400 Hz 至 500 Hz 500 µH 至 1 mH CMC 0,27 % 500 Hz 至 600 Hz 500 µH 至 1 mH CMC 0,25 % 600 Hz 至 900 Hz 500 µH 至 1 mH CMC 0,23 % 900 Hz 至 1 kHz 500 µH 至 1 mH CMC 0,21 % 1 kHz 至 2 kHz 500 µH 至 1 mH CMC 0,38 % 2 kHz 至 3 kHz 500 µH 至 1 mH CMC 0,27 % 3 kHz 至 5 kHz 500 µH 至 1 mH CMC 0,23 % 5 kHz 至 10 kHz 500 µH 至 1 mH CMC 0,21 % 10 kHz 至 25 kHz 500 µH 至 1 mH CMC 0,18 % 25 kHz 至 100 kHz 500 µH 至 1 mH CMC 0,12 % 100 kHz 至 300 kHz 500 µH 至 1 mH CMC 0,11 % 300 kHz 至 1 MHz 500 µH 至 1 mH CMC 0,17 % 20 Hz 至 30 Hz 1 mH 至 5 mH CMC 3,9 % 30 Hz 至 40 Hz 1 mH 至 5 mH CMC 2,5 % 40 Hz 至 50 Hz 1 mH 至 5 mH CMC 1,8 % 50 Hz 至 60 Hz 1 mH 至 5 mH CMC 1,3 % 60 Hz 至 80 Hz 1 mH 至 5 mH CMC 1,0 % 80 Hz 至 90 Hz 1 mH 至 5 mH CMC 0,74 % 90 Hz 至 100 Hz 1 mH 至 5 mH CMC 0,66 % 100 Hz 至 200 Hz 1 mH 至 5 mH CMC 0,38 % 200 Hz 至 300 Hz 1 mH 至 5 mH CMC 0,27 % 300 Hz 至 500 Hz 1 mH 至 5 mH CMC 0,23 % 500 Hz 至 700 Hz 1 mH 至 5 mH CMC 0,21 % 700 Hz 至 1 kHz 1 mH 至 5 mH CMC 0,19 % 1 kHz 至 3 kHz 1 mH 至 5 mH CMC 0,18 % 3 kHz 至 100 kHz 1 mH 至 5 mH CMC 0,12 % 100 kHz 至 300 kHz 1 mH 至 5 mH CMC 0,17 % 300 kHz 至 600 kHz 1 mH 至 5 mH CMC 0,21 % 600 kHz 至 1 MHz 1 mH 至 5 mH CMC 0,24 % 20 Hz 至 30 Hz 5 mH 至 10 mH CMC 1,1 % 30 Hz 至 40 Hz 5 mH 至 10 mH CMC 0,75 % 40 Hz 至 50 Hz 5 mH 至 10 mH CMC 0,61 % 50 Hz 至 60 Hz 5 mH 至 10 mH CMC 0,37 % 60 Hz 至 70 Hz 5 mH 至 10 mH CMC 0,33 % 70 Hz 至 80 Hz 5 mH 至 10 mH CMC 0,30 % 80 Hz 至 90 Hz 5 mH 至 10 mH CMC 0,28 % 90 Hz 至 100 Hz 5 mH 至 10 mH CMC 0,26 % 100 Hz 至 200 Hz 5 mH 至 10 mH CMC 0,38 % 200 Hz 至 300 Hz 5 mH 至 10 mH CMC 0,27 % 300 Hz 至 500 Hz 5 mH 至 10 mH CMC 0,23 % 500 Hz 至 700 Hz 5 mH 至 10 mH CMC 0,21 % 700 Hz 至 1 kHz 5 mH 至 10 mH CMC 0,19 % 1 kHz 至 3 kHz 5 mH 至 10 mH CMC 0,18 % 3 kHz 至 100 kHz 5 mH 至 10 mH CMC 0,12 % 100 kHz 至 300 kHz 5 mH 至 10 mH CMC 0,17 % 300 kHz 至 600 kHz 5 mH 至 10 mH CMC 0,21 % 600 kHz 至 1 MHz 5 mH 至 10 mH CMC 0,24 % 20 Hz 至 30 Hz 10 mH 至 50 mH CMC 0,69 % 30 Hz 至 40 Hz 10 mH 至 50 mH CMC 0,54 % 40 Hz 至 50 Hz 10 mH 至 50 mH CMC 0,47 % 50 Hz 至 60 Hz 10 mH 至 50 mH CMC 0,27 % 60 Hz 至 80 Hz 10 mH 至 50 mH CMC 0,24 % 80 Hz 至 100 Hz 10 mH 至 50 mH CMC 0,22 % 100 Hz 至 250 Hz 10 mH 至 50 mH CMC 0,18 % 250 Hz 至 1 kHz 10 mH 至 50 mH CMC 0,12 % 1 kHz 至 30 kHz 10 mH 至 50 mH CMC 0,11 % 30 kHz 至 100 kHz 10 mH 至 50 mH CMC 0,17 % 100 kHz 至 200 kHz 10 mH 至 50 mH CMC 0,21 % 200 kHz 至 300 kHz 10 mH 至 50 mH CMC 0,23 % 300 kHz 至 400 kHz 10 mH 至 50 mH CMC 0,31 % 400 kHz 至 500 kHz 10 mH 至 50 mH CMC 0,35 % 500 kHz 至 700 kHz 10 mH 至 50 mH CMC 0,43 % 700 kHz 至 1 MHz 10 mH 至 50 mH CMC 0,55 % 20 Hz 至 30 Hz 50 mH 至 100 mH CMC 0,40 % 30 Hz 至 50 Hz 50 mH 至 100 mH CMC 0,37 % 50 Hz 至 60 Hz 50 mH 至 100 mH CMC 0,27 % 60 Hz 至 80 Hz 50 mH 至 100 mH CMC 0,24 % 80 Hz 至 100 Hz 50 mH 至 100 mH CMC 0,22 % 100 Hz 至 250 Hz 50 mH 至 100 mH CMC 0,18 % 250 Hz 至 1 kHz 50 mH 至 100 mH CMC 0,12 % 1 kHz 至 30 kHz 50 mH 至 100 mH CMC 0,11 % 30 kHz 至 100 kHz 50 mH 至 100 mH CMC 0,17 % 100 kHz 至 200 kHz 50 mH 至 100 mH CMC 0,21 % 200 kHz 至 300 kHz 50 mH 至 100 mH CMC 0,23 % 300 kHz 至 400 kHz 50 mH 至 100 mH CMC 0,47 % 400 kHz 至 500 kHz 50 mH 至 100 mH CMC 0,55 % 500 kHz 至 600 kHz 50 mH 至 100 mH CMC 0,62 % 600 kHz 至 700 kHz 50 mH 至 100 mH CMC 0,70 % 700 kHz 至 800 kHz 50 mH 至 100 mH CMC 0,78 % 800 kHz 至 1 MHz 50 mH 至 100 mH CMC 0,93 % 20 Hz 至 30 Hz 100 mH 至 500 mH CMC 0,27 % 30 Hz 至 50 Hz 100 mH 至 500 mH CMC 0,35 % 50 Hz 至 100 Hz 100 mH 至 500 mH CMC 0,18 % 100 Hz 至 1 kHz 100 mH 至 500 mH CMC 0,12 % 1 kHz 至 30 kHz 100 mH 至 500 mH CMC 0,13 % 30 kHz 至 60 kHz 100 mH 至 500 mH CMC 0,21 % 60 kHz 至 100 kHz 100 mH 至 500 mH CMC 0,24 % 100 kHz 至 150 kHz 100 mH 至 500 mH CMC 0,33 % 150 kHz 至 200 kHz 100 mH 至 500 mH CMC 0,39 % 200 kHz 至 250 kHz 100 mH 至 500 mH CMC 0,45 % 250 kHz 至 300 kHz 100 mH 至 500 mH CMC 0,51 % 300 kHz 至 400 kHz 100 mH 至 500 mH CMC 1,8 % 400 kHz 至 500 kHz 100 mH 至 500 mH CMC 2,1 % 500 kHz 至 600 kHz 100 mH 至 500 mH CMC 2,5 % 600 kHz 至 700 kHz 100 mH 至 500 mH CMC 2,9 % 700 kHz 至 800 kHz 100 mH 至 500 mH CMC 3,3 % 800 kHz 至 900 kHz 100 mH 至 500 mH CMC 3,7 % 900 kHz 至 1 MHz 100 mH 至 500 mH CMC 4,1 % 20 Hz 至 30 Hz 500 mH 至 1 H CMC 0,27 % 30 Hz 至 50 Hz 500 mH 至 1 H CMC 0,35 % 50 Hz 至 100 Hz 500 mH 至 1 H CMC 0,18 % 100 Hz 至 1 kHz 500 mH 至 1 H CMC 0,12 % 1 kHz 至 30 kHz 500 mH 至 1 H CMC 0,13 % 30 kHz 至 60 kHz 500 mH 至 1 H CMC 0,21 % 60 kHz 至 100 kHz 500 mH 至 1 H CMC 0,24 % 100 kHz 至 150 kHz 500 mH 至 1 H CMC 0,51 % 150 kHz 至 200 kHz 500 mH 至 1 H CMC 0,62 % 200 kHz 至 250 kHz 500 mH 至 1 H CMC 0,74 % 250 kHz 至 300 kHz 500 mH 至 1 H CMC 0,86 % 300 kHz 至 400 kHz 500 mH 至 1 H CMC 3,3 % 400 kHz 至 500 kHz 500 mH 至 1 H CMC 4,1 % 500 kHz 至 600 kHz 500 mH 至 1 H CMC 4,9 % 600 kHz 至 700 kHz 500 mH 至 1 H CMC 5,6 % 700 kHz 至 800 kHz 500 mH 至 1 H CMC 6,4 % 800 kHz 至 900 kHz 500 mH 至 1 H CMC 7,2 % 900 kHz 至 1 MHz 500 mH 至 1 H CMC 8,0 % 20 Hz 至 50 Hz 1 H 至 2 H CMC 0,34 % 50 Hz 至 100 Hz 1 H 至 2 H CMC 0,18 % 100 Hz 至 1 kHz 1 H 至 2 H CMC 0,12 % 1 kHz 至 5 kHz 1 H 至 2 H CMC 0,15 % 5 kHz 至 10 kHz 1 H 至 2 H CMC 0,24 % 10 kHz 至 15 kHz 1 H 至 2 H CMC 0,28 % 15 kHz 至 20 kHz 1 H 至 2 H CMC 0,31 % 20 kHz 至 25 kHz 1 H 至 2 H CMC 0,35 % 25 kHz 至 30 kHz 1 H 至 2 H CMC 0,38 % 30 kHz 至 50 kHz 1 H 至 2 H CMC 0,35 % 50 kHz 至 70 kHz 1 H 至 2 H CMC 0,43 % 70 kHz 至 100 kHz 1 H 至 2 H CMC 0,55 % 100 kHz 至 150 kHz 1 H 至 2 H CMC 1,9 % 150 kHz 至 200 kHz 1 H 至 2 H CMC 2,5 % 200 kHz 至 250 kHz 1 H 至 2 H CMC 3,1 % 250 kHz 至 300 kHz 1 H 至 2 H CMC 3,7 % 300 kHz 至 400 kHz 1 H 至 2 H CMC 6,4 % 400 kHz 至 500 kHz 1 H 至 2 H CMC 8,0 % 20 Hz 至 50 Hz 2 H 至 5 H CMC 0,34 % 50 Hz 至 100 Hz 2 H 至 5 H CMC 0,18 % 100 Hz 至 1 kHz 2 H 至 5 H CMC 0,12 % 1 kHz 至 5 kHz 2 H 至 5 H CMC 0,15 % 5 kHz 至 10 kHz 2 H 至 5 H CMC 0,24 % 10 kHz 至 15 kHz 2 H 至 5 H CMC 0,28 % 15 kHz 至 20 kHz 2 H 至 5 H CMC 0,31 % 20 kHz 至 25 kHz 2 H 至 5 H CMC 0,35 % 25 kHz 至 30 kHz 2 H 至 5 H CMC 0,38 % 30 kHz 至 50 kHz 2 H 至 5 H CMC 0,35 % 50 kHz 至 70 kHz 2 H 至 5 H CMC 0,43 % 70 kHz 至 100 kHz 2 H 至 5 H CMC 0,55 % 100 kHz 至 150 kHz 2 H 至 5 H CMC 1,9 % 150 kHz 至 200 kHz 2 H 至 5 H CMC 2,5 % 200 kHz 至 250 kHz 2 H 至 5 H CMC 3,1 % 250 kHz 至 300 kHz 2 H 至 5 H CMC 3,7 % 50 Hz 至 100 Hz 5 H 至 10 H CMC 0,18 % 100 Hz 至 1 kHz 5 H 至 10 H CMC 0,12 % 1 kHz 至 5 kHz 5 H 至 10 H CMC 0,15 % 5 kHz 至 10 kHz 5 H 至 10 H CMC 0,24 % 10 kHz 至 15 kHz 5 H 至 10 H CMC 0,28 % 15 kHz 至 20 kHz 5 H 至 10 H CMC 0,31 % 20 kHz 至 25 kHz 5 H 至 10 H CMC 0,35 % 25 kHz 至 30 kHz 5 H 至 10 H CMC 0,38 % 30 kHz 至 40 kHz 5 H 至 10 H CMC 0,47 % 40 kHz 至 50 kHz 5 H 至 10 H CMC 0,55 % 50 kHz 至 60 kHz 5 H 至 10 H CMC 0,62 % 60 kHz 至 70 kHz 5 H 至 10 H CMC 0,70 % 70 kHz 至 80 kHz 5 H 至 10 H CMC 0,78 % 80 kHz 至 90 kHz 5 H 至 10 H CMC 0,86 % 90 kHz 至 100 kHz 5 H 至 10 H CMC 0,93 % 100 kHz 至 150 kHz 5 H 至 10 H CMC 3,7 % 150 kHz 至 200 kHz 5 H 至 10 H CMC 4,9 % 200 kHz 至 250 kHz 5 H 至 10 H CMC 6,0 % 250 kHz 至 300 kHz 5 H 至 10 H CMC 7,2 % 50 Hz 至 100 Hz 10 H 至 50 H CMC 0,18 % 100 Hz 至 500 Hz 10 H 至 50 H CMC 0,15 % 500 Hz 至 800 Hz 10 H 至 50 H CMC 0,22 % 800 Hz 至 2 kHz 10 H 至 50 H CMC 0,24 % 2 kHz 至 3 kHz 10 H 至 50 H CMC 0,28 % 3 kHz 至 5 kHz 10 H 至 50 H CMC 0,35 % 5 kHz 至 7 kHz 10 H 至 50 H CMC 0,43 % 7 kHz 至 10 kHz 10 H 至 50 H CMC 0,55 % 10 kHz 至 15 kHz 10 H 至 50 H CMC 0,74 % 15 kHz 至 20 kHz 10 H 至 50 H CMC 0,93 % 20 kHz 至 25 kHz 10 H 至 50 H CMC 1,2 % 25 kHz 至 30 kHz 10 H 至 50 H CMC 1,4 % 30 kHz 至 40 kHz 10 H 至 50 H CMC 1,8 % 40 kHz 至 50 kHz 10 H 至 50 H CMC 2,1 % 50 kHz 至 60 kHz 10 H 至 50 H CMC 2,5 % 60 kHz 至 70 kHz 10 H 至 50 H CMC 2,9 % 70 kHz 至 80 kHz 10 H 至 50 H CMC 3,3 % 80 kHz 至 90 kHz 10 H 至 50 H CMC 3,7 % 90 kHz 至 100 kHz 10 H 至 50 H CMC 4,1 % 50 Hz 至 100 Hz 50 H 至 100 H CMC 0,18 % 100 Hz 至 500 Hz 50 H 至 100 H CMC 0,15 % 500 Hz 至 800 Hz 50 H 至 100 H CMC 0,22 % 800 Hz 至 1 kHz 50 H 至 100 H CMC 0,24 % 1 kHz 至 2 kHz 50 H 至 100 H CMC 0,31 % 2 kHz 至 3 kHz 50 H 至 100 H CMC 0,39 % 3 kHz 至 5 kHz 50 H 至 100 H CMC 0,55 % 5 kHz 至 7 kHz 50 H 至 100 H CMC 0,70 % 7 kHz 至 10 kHz 50 H 至 100 H CMC 0,93 % 10 kHz 至 15 kHz 50 H 至 100 H CMC 1,4 % 15 kHz 至 20 kHz 50 H 至 100 H CMC 1,8 % 20 kHz 至 25 kHz 50 H 至 100 H CMC 2,1 % 25 kHz 至 30 kHz 50 H 至 100 H CMC 2,5 % 20 Hz 至 35 Hz 100 H 至 500 H CMC 0,38 % 35 Hz 至 50 Hz 100 H 至 500 H CMC 0,40 % 50 Hz 至 70 Hz 100 H 至 500 H CMC 0,28 % 70 Hz 至 200 Hz 100 H 至 500 H CMC 0,31 % 200 Hz 至 300 Hz 100 H 至 500 H CMC 0,39 % 300 Hz 至 400 Hz 100 H 至 500 H CMC 0,47 % 400 Hz 至 500 Hz 100 H 至 500 H CMC 0,55 % 500 Hz 至 600 Hz 100 H 至 500 H CMC 0,62 % 600 Hz 至 700 Hz 100 H 至 500 H CMC 0,70 % 700 Hz 至 800 Hz 100 H 至 500 H CMC 0,78 % 800 Hz 至 900 Hz 100 H 至 500 H CMC 0,86 % 900 Hz 至 2 kHz 100 H 至 500 H CMC 0,93 % 2 kHz 至 3 kHz 100 H 至 500 H CMC 1,4 % 3 kHz 至 5 kHz 100 H 至 500 H CMC 2,1 % 5 kHz 至 7 kHz 100 H 至 500 H CMC 2,9 % 7 kHz 至 8 kHz 100 H 至 500 H CMC 3,3 % 8 kHz 至 9 kHz 100 H 至 500 H CMC 3,7 % 9 kHz 至 10 kHz 100 H 至 500 H CMC 4,1 % 20 Hz 至 35 Hz 500 H 至 1 kH CMC 0,38 % 35 Hz 至 50 Hz 500 H 至 1 kH CMC 0,40 % 50 Hz 至 70 Hz 500 H 至 1 kH CMC 0,28 % 70 Hz 至 100 Hz 500 H 至 1 kH CMC 0,31 % 100 Hz 至 200 Hz 500 H 至 1 kH CMC 0,31 % 200 Hz 至 300 Hz 500 H 至 1 kH CMC 0,39 % 300 Hz 至 400 Hz 500 H 至 1 kH CMC 0,47 % 400 Hz 至 500 Hz 500 H 至 1 kH CMC 0,55 % 500 Hz 至 600 Hz 500 H 至 1 kH CMC 0,62 % 600 Hz 至 700 Hz 500 H 至 1 kH CMC 0,70 % 700 Hz 至 800 Hz 500 H 至 1 kH CMC 0,78 % 800 Hz 至 900 Hz 500 H 至 1 kH CMC 0,86 % 900 Hz 至 1 kHz 500 H 至 1 kH CMC 0,93 % TP8, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c665faa9e3a260734f5318f1","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"9","test_object":"Indukcyjność / Mierniki indukcyjności","test_object_en":"Inductance / Inductance meters","test_object_zh":"电感 / 电感测量仪器","test_object_cs":"Indukčnost / Měřidla indukčnosti","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"1 µH","cmc":"0,20 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,14 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"1 mH","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"10 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"100 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz","range":"1 H","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz","range":"10 H","cmc":"0,05 %"},{"name":"1 kHz","range":"100 H","cmc":"0,2 %"},{"name":"1 kHz","range":"1000 H","cmc":"1,5 %"}],"parameters_en":[{"name":"1 kHz","range":"1 µH","cmc":"0,20 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,14 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"1 mH","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"10 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"100 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz","range":"1 H","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz","range":"10 H","cmc":"0,05 %"},{"name":"1 kHz","range":"100 H","cmc":"0,2 %"},{"name":"1 kHz","range":"1000 H","cmc":"1,5 %"}],"parameters_zh":[{"name":"1 kHz","range":"1 µH","cmc":"0,20 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,14 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"1 mH","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"10 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"100 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz","range":"1 H","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz","range":"10 H","cmc":"0,05 %"},{"name":"1 kHz","range":"100 H","cmc":"0,2 %"},{"name":"1 kHz","range":"1000 H","cmc":"1,5 %"}],"parameters_cs":[{"name":"1 kHz","range":"1 µH","cmc":"0,20 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,14 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"1 mH","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"10 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz, 10 kHz","range":"100 mH","cmc":"0,03 %"},{"name":"100 Hz, 1 kHz","range":"1 H","cmc":"0,02 %"},{"name":"100 Hz, 1 kHz","range":"10 H","cmc":"0,05 %"},{"name":"1 kHz","range":"100 H","cmc":"0,2 %"},{"name":"1 kHz","range":"1000 H","cmc":"1,5 %"}],"technique":"Pomiar bezpośredni wzorca indukcyjności","technique_en":"Direct measurement of an inductance standard","technique_zh":"直接测量电感标准器","technique_cs":"Přímé měření etalonu indukčnosti","techniques":["Pomiar bezpośredni wzorca indukcyjności"],"techniques_en":["Direct measurement of an inductance standard"],"techniques_zh":["直接测量电感标准器"],"techniques_cs":["Přímé měření etalonu indukčnosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz 1 µH CMC 0,20 %\n1 kHz 10 µH CMC 0,14 %\n1 kHz 100 µH CMC 0,03 %\n100 Hz, 1 kHz, 10 kHz 1 mH CMC 0,02 %\n100 Hz, 1 kHz, 10 kHz 10 mH CMC 0,03 %\n100 Hz, 1 kHz, 10 kHz 100 mH CMC 0,03 %\n100 Hz, 1 kHz 1 H CMC 0,02 %\n100 Hz, 1 kHz 10 H CMC 0,05 %\n1 kHz 100 H CMC 0,2 %\n1 kHz 1000 H CMC 1,5 %\nPomiar bezpośredni wzorca indukcyjności","reference":"TP8, TP24","norm_bases":["TP8","TP24"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indukcyjność / Mierniki indukcyjności Wzorcowanie – wielkości elektryczne Pomiar bezpośredni wzorca indukcyjności 1 kHz 1 µH CMC 0,20 % 1 kHz 10 µH CMC 0,14 % 1 kHz 100 µH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 1 mH CMC 0,02 % 100 Hz, 1 kHz, 10 kHz 10 mH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 100 mH CMC 0,03 % 100 Hz, 1 kHz 1 H CMC 0,02 % 100 Hz, 1 kHz 10 H CMC 0,05 % 1 kHz 100 H CMC 0,2 % 1 kHz 1000 H CMC 1,5 % Indukčnost / Měřidla indukčnosti Kalibrace – elektrické veličiny Přímé měření etalonu indukčnosti 1 kHz 1 µH CMC 0,20 % 1 kHz 10 µH CMC 0,14 % 1 kHz 100 µH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 1 mH CMC 0,02 % 100 Hz, 1 kHz, 10 kHz 10 mH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 100 mH CMC 0,03 % 100 Hz, 1 kHz 1 H CMC 0,02 % 100 Hz, 1 kHz 10 H CMC 0,05 % 1 kHz 100 H CMC 0,2 % 1 kHz 1000 H CMC 1,5 % TP8, TP24 Indukcyjnosc / Mierniki indukcyjnosci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni wzorca indukcyjnosci 1 kHz 1 µH CMC 0,20 % 1 kHz 10 µH CMC 0,14 % 1 kHz 100 µH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 1 mH CMC 0,02 % 100 Hz, 1 kHz, 10 kHz 10 mH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 100 mH CMC 0,03 % 100 Hz, 1 kHz 1 H CMC 0,02 % 100 Hz, 1 kHz 10 H CMC 0,05 % 1 kHz 100 H CMC 0,2 % 1 kHz 1000 H CMC 1,5 % Indukcnost / Meridla indukcnosti Kalibrace – elektricke veliciny Prime mereni etalonu indukcnosti 1 kHz 1 µH CMC 0,20 % 1 kHz 10 µH CMC 0,14 % 1 kHz 100 µH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 1 mH CMC 0,02 % 100 Hz, 1 kHz, 10 kHz 10 mH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 100 mH CMC 0,03 % 100 Hz, 1 kHz 1 H CMC 0,02 % 100 Hz, 1 kHz 10 H CMC 0,05 % 1 kHz 100 H CMC 0,2 % 1 kHz 1000 H CMC 1,5 % TP8, TP24","search_en":"Inductance / Inductance meters Calibration – electrical quantities Direct measurement of an inductance standard 1 kHz 1 µH CMC 0,20 % 1 kHz 10 µH CMC 0,14 % 1 kHz 100 µH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 1 mH CMC 0,02 % 100 Hz, 1 kHz, 10 kHz 10 mH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 100 mH CMC 0,03 % 100 Hz, 1 kHz 1 H CMC 0,02 % 100 Hz, 1 kHz 10 H CMC 0,05 % 1 kHz 100 H CMC 0,2 % 1 kHz 1000 H CMC 1,5 % TP8, TP24","search_zh":"电感 / 电感测量仪器 校准 – 电学量 直接测量电感标准器 1 kHz 1 µH CMC 0,20 % 1 kHz 10 µH CMC 0,14 % 1 kHz 100 µH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 1 mH CMC 0,02 % 100 Hz, 1 kHz, 10 kHz 10 mH CMC 0,03 % 100 Hz, 1 kHz, 10 kHz 100 mH CMC 0,03 % 100 Hz, 1 kHz 1 H CMC 0,02 % 100 Hz, 1 kHz 10 H CMC 0,05 % 1 kHz 100 H CMC 0,2 % 1 kHz 1000 H CMC 1,5 % TP8, TP24","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a69ad41e7037ecac6f6d2355","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"10","test_object":"Zniekształcenia nieliniowe / Mierniki zniekształceń nieliniowych","test_object_en":"Non-linear distortion / Non-linear distortion meters","test_object_zh":"非线性失真 / 非线性失真测量仪器","test_object_cs":"Nelineární zkreslení / Měřidla nelineárního zkreslení","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 20 kHz","range":"od 0,01 % do 100 %","cmc":"0,003 %"},{"name":"20 kHz do 50 kHz","range":"od 0,01 % do 100 %","cmc":"0,03 %"},{"name":"50 kHz do 100 kHz","range":"od 0,01 % do 100 %","cmc":"0,05 %"}],"parameters_en":[{"name":"20 Hz to 20 kHz","range":"0,01 % to 100 %","cmc":"0,003 %"},{"name":"20 kHz to 50 kHz","range":"0,01 % to 100 %","cmc":"0,03 %"},{"name":"50 kHz to 100 kHz","range":"0,01 % to 100 %","cmc":"0,05 %"}],"parameters_zh":[{"name":"20 Hz 至 20 kHz","range":"0,01 % 至 100 %","cmc":"0,003 %"},{"name":"20 kHz 至 50 kHz","range":"0,01 % 至 100 %","cmc":"0,03 %"},{"name":"50 kHz 至 100 kHz","range":"0,01 % 至 100 %","cmc":"0,05 %"}],"parameters_cs":[{"name":"20 Hz až 20 kHz","range":"0,01 % až 100 %","cmc":"0,003 %"},{"name":"20 kHz až 50 kHz","range":"0,01 % až 100 %","cmc":"0,03 %"},{"name":"50 kHz až 100 kHz","range":"0,01 % až 100 %","cmc":"0,05 %"}],"technique":"Porównanie z analizatorem zniekształceń","technique_en":"Comparison with a distortion analyzer","technique_zh":"与失真分析仪比较","technique_cs":"Porovnání s analyzátorem zkreslení","techniques":["Porównanie z analizatorem zniekształceń"],"techniques_en":["Comparison with a distortion analyzer"],"techniques_zh":["与失真分析仪比较"],"techniques_cs":["Porovnání s analyzátorem zkreslení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 20 kHz od 0,01 % do 100 % CMC 0,003 %\n20 kHz do 50 kHz od 0,01 % do 100 % CMC 0,03 %\n50 kHz do 100 kHz od 0,01 % do 100 % CMC 0,05 %\nPorównanie z analizatorem zniekształceń","reference":"TP10","norm_bases":["TP10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zniekształcenia nieliniowe / Mierniki zniekształceń nieliniowych Wzorcowanie – wielkości elektryczne Porównanie z analizatorem zniekształceń 20 Hz do 20 kHz od 0,01 % do 100 % CMC 0,003 % 20 kHz do 50 kHz od 0,01 % do 100 % CMC 0,03 % 50 kHz do 100 kHz od 0,01 % do 100 % CMC 0,05 % Nelineární zkreslení / Měřidla nelineárního zkreslení Kalibrace – elektrické veličiny Porovnání s analyzátorem zkreslení 20 Hz až 20 kHz 0,01 % až 100 % CMC 0,003 % 20 kHz až 50 kHz 0,01 % až 100 % CMC 0,03 % 50 kHz až 100 kHz 0,01 % až 100 % CMC 0,05 % TP10 Znieksztalcenia nieliniowe / Mierniki znieksztalcen nieliniowych Wzorcowanie – wielkosci elektryczne Porownanie z analizatorem znieksztalcen 20 Hz do 20 kHz od 0,01 % do 100 % CMC 0,003 % 20 kHz do 50 kHz od 0,01 % do 100 % CMC 0,03 % 50 kHz do 100 kHz od 0,01 % do 100 % CMC 0,05 % Nelinearni zkresleni / Meridla nelinearniho zkresleni Kalibrace – elektricke veliciny Porovnani s analyzatorem zkresleni 20 Hz az 20 kHz 0,01 % az 100 % CMC 0,003 % 20 kHz az 50 kHz 0,01 % az 100 % CMC 0,03 % 50 kHz az 100 kHz 0,01 % az 100 % CMC 0,05 % TP10","search_en":"Non-linear distortion / Non-linear distortion meters Calibration – electrical quantities Comparison with a distortion analyzer 20 Hz to 20 kHz 0,01 % to 100 % CMC 0,003 % 20 kHz to 50 kHz 0,01 % to 100 % CMC 0,03 % 50 kHz to 100 kHz 0,01 % to 100 % CMC 0,05 % TP10","search_zh":"非线性失真 / 非线性失真测量仪器 校准 – 电学量 与失真分析仪比较 20 Hz 至 20 kHz 0,01 % 至 100 % CMC 0,003 % 20 kHz 至 50 kHz 0,01 % 至 100 % CMC 0,03 % 50 kHz 至 100 kHz 0,01 % 至 100 % CMC 0,05 % TP10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1c61a8d5b7bf4c09c5fe9403","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"10","test_object":"Zniekształcenia nieliniowe / Generatory sygnału sinusoidalnego","test_object_en":"Nonlinear distortion / sine signal generators","test_object_zh":"非线性失真 / 正弦信号发生器","test_object_cs":"Nelineární zkreslení / Generátory sinusového signálu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 20 kHz (BW 80 kHz)","range":"od 0,01 % do 100 %","cmc":"1 dB + 0,01 % (abs.)"},{"name":"20 kHz do 50 kHz (BW 500 kHz)","range":"od 0,01 % do 100 %","cmc":"2 dB + 0,04 % (abs.)"},{"name":"50 kHz do 100 kHz (BW 500 kHz)","range":"od 0,01 % do 100 %","cmc":"2 dB + 0,06 % (abs.)"}],"parameters_en":[{"name":"20 Hz to 20 kHz (BW 80 kHz)","range":"0,01 % to 100 %","cmc":"1 dB + 0,01 % (abs.)"},{"name":"20 kHz to 50 kHz (BW 500 kHz)","range":"0,01 % to 100 %","cmc":"2 dB + 0,04 % (abs.)"},{"name":"50 kHz to 100 kHz (BW 500 kHz)","range":"0,01 % to 100 %","cmc":"2 dB + 0,06 % (abs.)"}],"parameters_zh":[{"name":"20 Hz 至 20 kHz（BW 80 kHz）","range":"0,01 % 至 100 %","cmc":"1 dB + 0,01 % (abs.)"},{"name":"20 kHz 至 50 kHz（BW 500 kHz）","range":"0,01 % 至 100 %","cmc":"2 dB + 0,04 % (abs.)"},{"name":"50 kHz 至 100 kHz（BW 500 kHz）","range":"0,01 % 至 100 %","cmc":"2 dB + 0,06 % (abs.)"}],"parameters_cs":[{"name":"20 Hz až 20 kHz (BW 80 kHz)","range":"0,01 % až 100 %","cmc":"1 dB + 0,01 % (abs.)"},{"name":"20 kHz až 50 kHz (BW 500 kHz)","range":"0,01 % až 100 %","cmc":"2 dB + 0,04 % (abs.)"},{"name":"50 kHz až 100 kHz (BW 500 kHz)","range":"0,01 % až 100 %","cmc":"2 dB + 0,06 % (abs.)"}],"technique":"Pomiar analizatorem zniekształceń","technique_en":"Measurement by a distortion analyzer","technique_zh":"用失真分析仪测量","technique_cs":"Měření analyzátorem zkreslení","techniques":["Pomiar analizatorem zniekształceń"],"techniques_en":["Measurement by a distortion analyzer"],"techniques_zh":["用失真分析仪测量"],"techniques_cs":["Měření analyzátorem zkreslení"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 20 kHz (BW 80 kHz) od 0,01 % do 100 % CMC 1 dB + 0,01 % (abs.)\n20 kHz do 50 kHz (BW 500 kHz) od 0,01 % do 100 % CMC 2 dB + 0,04 % (abs.)\n50 kHz do 100 kHz (BW 500 kHz) od 0,01 % do 100 % CMC 2 dB + 0,06 % (abs.)\nPomiar analizatorem zniekształceń","reference":"TP10","norm_bases":["TP10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zniekształcenia nieliniowe / Generatory sygnału sinusoidalnego Wzorcowanie – wielkości elektryczne Pomiar analizatorem zniekształceń 20 Hz do 20 kHz (BW 80 kHz) od 0,01 % do 100 % CMC 1 dB + 0,01 % (abs.) 20 kHz do 50 kHz (BW 500 kHz) od 0,01 % do 100 % CMC 2 dB + 0,04 % (abs.) 50 kHz do 100 kHz (BW 500 kHz) od 0,01 % do 100 % CMC 2 dB + 0,06 % (abs.) Nelineární zkreslení / Generátory sinusového signálu Kalibrace – elektrické veličiny Měření analyzátorem zkreslení 20 Hz až 20 kHz (BW 80 kHz) 0,01 % až 100 % CMC 1 dB + 0,01 % (abs.) 20 kHz až 50 kHz (BW 500 kHz) 0,01 % až 100 % CMC 2 dB + 0,04 % (abs.) 50 kHz až 100 kHz (BW 500 kHz) 0,01 % až 100 % CMC 2 dB + 0,06 % (abs.) TP10 Znieksztalcenia nieliniowe / Generatory sygnalu sinusoidalnego Wzorcowanie – wielkosci elektryczne Pomiar analizatorem znieksztalcen 20 Hz do 20 kHz (BW 80 kHz) od 0,01 % do 100 % CMC 1 dB + 0,01 % (abs.) 20 kHz do 50 kHz (BW 500 kHz) od 0,01 % do 100 % CMC 2 dB + 0,04 % (abs.) 50 kHz do 100 kHz (BW 500 kHz) od 0,01 % do 100 % CMC 2 dB + 0,06 % (abs.) Nelinearni zkresleni / Generatory sinusoveho signalu Kalibrace – elektricke veliciny Mereni analyzatorem zkresleni 20 Hz az 20 kHz (BW 80 kHz) 0,01 % az 100 % CMC 1 dB + 0,01 % (abs.) 20 kHz az 50 kHz (BW 500 kHz) 0,01 % az 100 % CMC 2 dB + 0,04 % (abs.) 50 kHz az 100 kHz (BW 500 kHz) 0,01 % az 100 % CMC 2 dB + 0,06 % (abs.) TP10","search_en":"Nonlinear distortion / sine signal generators Calibration – electrical quantities Measurement by a distortion analyzer 20 Hz to 20 kHz (BW 80 kHz) 0,01 % to 100 % CMC 1 dB + 0,01 % (abs.) 20 kHz to 50 kHz (BW 500 kHz) 0,01 % to 100 % CMC 2 dB + 0,04 % (abs.) 50 kHz to 100 kHz (BW 500 kHz) 0,01 % to 100 % CMC 2 dB + 0,06 % (abs.) TP10","search_zh":"非线性失真 / 正弦信号发生器 校准 – 电学量 用失真分析仪测量 20 Hz 至 20 kHz（BW 80 kHz） 0,01 % 至 100 % CMC 1 dB + 0,01 % (abs.) 20 kHz 至 50 kHz（BW 500 kHz） 0,01 % 至 100 % CMC 2 dB + 0,04 % (abs.) 50 kHz 至 100 kHz（BW 500 kHz） 0,01 % 至 100 % CMC 2 dB + 0,06 % (abs.) TP10","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91e7aad9a77c7cad8e227b20","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"11","test_object":"Moc w.cz. / Mierniki i źródła mocy w.cz. oraz analizatory widma, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części","test_object_en":"HF power / HF power meters and sources and spectrum analyzers, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts","test_object_zh":"高频功率 / 高频功率计和功率源以及频谱分析仪、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件","test_object_cs":"VF výkon / Měřidla a zdroje VF výkonu a spektrální analyzátory, radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 MHz do 1 GHz","range":"od -50 dBm do -20 dBm","cmc":"4,8 %"},{"name":"1 GHz do 9 GHz","range":"od -50 dBm do -20 dBm","cmc":"5,0 %"},{"name":"9 GHz do 18 GHz","range":"od -50 dBm do -20 dBm","cmc":"5,4 %"},{"name":"10 MHz do 1 GHz","range":"od -20 dBm do 0 dBm","cmc":"3,4 %"},{"name":"1 GHz do 9 GHz","range":"od -20 dBm do 0 dBm","cmc":"3,7 %"},{"name":"9 GHz do 18 GHz","range":"od -20 dBm do 0 dBm","cmc":"4,3 %"},{"name":"10 MHz do 1 GHz","range":"0 dBm","cmc":"3,0 %"},{"name":"1 GHz do 9 GHz","range":"0 dBm","cmc":"3,2 %"},{"name":"9 GHz do 18 GHz","range":"0 dBm","cmc":"3,8 %"},{"name":"10 MHz do 30 MHz","range":"od 0 dBm do 17 dBm","cmc":"6,5 %"},{"name":"30 MHz do 9 GHz","range":"od 0 dBm do 17 dBm","cmc":"4,1 %"},{"name":"9 GHz do 18 GHz","range":"od 0 dBm do 17 dBm","cmc":"4,4 %"},{"name":"10 MHz do 9 GHz","range":"od 17 dBm do 40 dBm","cmc":"4,4 %"},{"name":"9 GHz do 18 GHz","range":"od 17 dBm do 40 dBm","cmc":"5,7 %"}],"parameters_en":[{"name":"10 MHz to 1 GHz","range":"-50 dBm to -20 dBm","cmc":"4,8 %"},{"name":"1 GHz to 9 GHz","range":"-50 dBm to -20 dBm","cmc":"5,0 %"},{"name":"9 GHz to 18 GHz","range":"-50 dBm to -20 dBm","cmc":"5,4 %"},{"name":"10 MHz to 1 GHz","range":"-20 dBm to 0 dBm","cmc":"3,4 %"},{"name":"1 GHz to 9 GHz","range":"-20 dBm to 0 dBm","cmc":"3,7 %"},{"name":"9 GHz to 18 GHz","range":"-20 dBm to 0 dBm","cmc":"4,3 %"},{"name":"10 MHz to 1 GHz","range":"0 dBm","cmc":"3,0 %"},{"name":"1 GHz to 9 GHz","range":"0 dBm","cmc":"3,2 %"},{"name":"9 GHz to 18 GHz","range":"0 dBm","cmc":"3,8 %"},{"name":"10 MHz to 30 MHz","range":"0 dBm to 17 dBm","cmc":"6,5 %"},{"name":"30 MHz to 9 GHz","range":"0 dBm to 17 dBm","cmc":"4,1 %"},{"name":"9 GHz to 18 GHz","range":"0 dBm to 17 dBm","cmc":"4,4 %"},{"name":"10 MHz to 9 GHz","range":"17 dBm to 40 dBm","cmc":"4,4 %"},{"name":"9 GHz to 18 GHz","range":"17 dBm to 40 dBm","cmc":"5,7 %"}],"parameters_zh":[{"name":"10 MHz 至 1 GHz","range":"-50 dBm 至 -20 dBm","cmc":"4,8 %"},{"name":"1 GHz 至 9 GHz","range":"-50 dBm 至 -20 dBm","cmc":"5,0 %"},{"name":"9 GHz 至 18 GHz","range":"-50 dBm 至 -20 dBm","cmc":"5,4 %"},{"name":"10 MHz 至 1 GHz","range":"-20 dBm 至 0 dBm","cmc":"3,4 %"},{"name":"1 GHz 至 9 GHz","range":"-20 dBm 至 0 dBm","cmc":"3,7 %"},{"name":"9 GHz 至 18 GHz","range":"-20 dBm 至 0 dBm","cmc":"4,3 %"},{"name":"10 MHz 至 1 GHz","range":"0 dBm","cmc":"3,0 %"},{"name":"1 GHz 至 9 GHz","range":"0 dBm","cmc":"3,2 %"},{"name":"9 GHz 至 18 GHz","range":"0 dBm","cmc":"3,8 %"},{"name":"10 MHz 至 30 MHz","range":"0 dBm 至 17 dBm","cmc":"6,5 %"},{"name":"30 MHz 至 9 GHz","range":"0 dBm 至 17 dBm","cmc":"4,1 %"},{"name":"9 GHz 至 18 GHz","range":"0 dBm 至 17 dBm","cmc":"4,4 %"},{"name":"10 MHz 至 9 GHz","range":"17 dBm 至 40 dBm","cmc":"4,4 %"},{"name":"9 GHz 至 18 GHz","range":"17 dBm 至 40 dBm","cmc":"5,7 %"}],"parameters_cs":[{"name":"10 MHz až 1 GHz","range":"-50 dBm až -20 dBm","cmc":"4,8 %"},{"name":"1 GHz až 9 GHz","range":"-50 dBm až -20 dBm","cmc":"5,0 %"},{"name":"9 GHz až 18 GHz","range":"-50 dBm až -20 dBm","cmc":"5,4 %"},{"name":"10 MHz až 1 GHz","range":"-20 dBm až 0 dBm","cmc":"3,4 %"},{"name":"1 GHz až 9 GHz","range":"-20 dBm až 0 dBm","cmc":"3,7 %"},{"name":"9 GHz až 18 GHz","range":"-20 dBm až 0 dBm","cmc":"4,3 %"},{"name":"10 MHz až 1 GHz","range":"0 dBm","cmc":"3,0 %"},{"name":"1 GHz až 9 GHz","range":"0 dBm","cmc":"3,2 %"},{"name":"9 GHz až 18 GHz","range":"0 dBm","cmc":"3,8 %"},{"name":"10 MHz až 30 MHz","range":"0 dBm až 17 dBm","cmc":"6,5 %"},{"name":"30 MHz až 9 GHz","range":"0 dBm až 17 dBm","cmc":"4,1 %"},{"name":"9 GHz až 18 GHz","range":"0 dBm až 17 dBm","cmc":"4,4 %"},{"name":"10 MHz až 9 GHz","range":"17 dBm až 40 dBm","cmc":"4,4 %"},{"name":"9 GHz až 18 GHz","range":"17 dBm až 40 dBm","cmc":"5,7 %"}],"technique":"Pomiar watomierzem, 50 Ω","technique_en":"Measurement by a wattmeter, 50 Ω","technique_zh":"用功率计测量，50 Ω","technique_cs":"Měření wattmetrem, 50 Ω","techniques":["Pomiar watomierzem, 50 Ω"],"techniques_en":["Measurement by a wattmeter, 50 Ω"],"techniques_zh":["用功率计测量，50 Ω"],"techniques_cs":["Měření wattmetrem, 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 MHz do 1 GHz od -50 dBm do -20 dBm CMC 4,8 %\n1 GHz do 9 GHz od -50 dBm do -20 dBm CMC 5,0 %\n9 GHz do 18 GHz od -50 dBm do -20 dBm CMC 5,4 %\n10 MHz do 1 GHz od -20 dBm do 0 dBm CMC 3,4 %\n1 GHz do 9 GHz od -20 dBm do 0 dBm CMC 3,7 %\n9 GHz do 18 GHz od -20 dBm do 0 dBm CMC 4,3 %\n10 MHz do 1 GHz 0 dBm CMC 3,0 %\n1 GHz do 9 GHz 0 dBm CMC 3,2 %\n9 GHz do 18 GHz 0 dBm CMC 3,8 %\n10 MHz do 30 MHz od 0 dBm do 17 dBm CMC 6,5 %\n30 MHz do 9 GHz od 0 dBm do 17 dBm CMC 4,1 %\n9 GHz do 18 GHz od 0 dBm do 17 dBm CMC 4,4 %\n10 MHz do 9 GHz od 17 dBm do 40 dBm CMC 4,4 %\n9 GHz do 18 GHz od 17 dBm do 40 dBm CMC 5,7 %\nPomiar watomierzem, 50 Ω","reference":"TP11, TP23","norm_bases":["TP11","TP23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc w.cz. / Mierniki i źródła mocy w.cz. oraz analizatory widma, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części Wzorcowanie – wielkości elektryczne Pomiar watomierzem, 50 Ω 10 MHz do 1 GHz od -50 dBm do -20 dBm CMC 4,8 % 1 GHz do 9 GHz od -50 dBm do -20 dBm CMC 5,0 % 9 GHz do 18 GHz od -50 dBm do -20 dBm CMC 5,4 % 10 MHz do 1 GHz od -20 dBm do 0 dBm CMC 3,4 % 1 GHz do 9 GHz od -20 dBm do 0 dBm CMC 3,7 % 9 GHz do 18 GHz od -20 dBm do 0 dBm CMC 4,3 % 10 MHz do 1 GHz 0 dBm CMC 3,0 % 1 GHz do 9 GHz 0 dBm CMC 3,2 % 9 GHz do 18 GHz 0 dBm CMC 3,8 % 10 MHz do 30 MHz od 0 dBm do 17 dBm CMC 6,5 % 30 MHz do 9 GHz od 0 dBm do 17 dBm CMC 4,1 % 9 GHz do 18 GHz od 0 dBm do 17 dBm CMC 4,4 % 10 MHz do 9 GHz od 17 dBm do 40 dBm CMC 4,4 % 9 GHz do 18 GHz od 17 dBm do 40 dBm CMC 5,7 % VF výkon / Měřidla a zdroje VF výkonu a spektrální analyzátory, radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části Kalibrace – elektrické veličiny Měření wattmetrem, 50 Ω 10 MHz až 1 GHz -50 dBm až -20 dBm CMC 4,8 % 1 GHz až 9 GHz -50 dBm až -20 dBm CMC 5,0 % 9 GHz až 18 GHz -50 dBm až -20 dBm CMC 5,4 % 10 MHz až 1 GHz -20 dBm až 0 dBm CMC 3,4 % 1 GHz až 9 GHz -20 dBm až 0 dBm CMC 3,7 % 9 GHz až 18 GHz -20 dBm až 0 dBm CMC 4,3 % 10 MHz až 1 GHz 0 dBm CMC 3,0 % 1 GHz až 9 GHz 0 dBm CMC 3,2 % 9 GHz až 18 GHz 0 dBm CMC 3,8 % 10 MHz až 30 MHz 0 dBm až 17 dBm CMC 6,5 % 30 MHz až 9 GHz 0 dBm až 17 dBm CMC 4,1 % 9 GHz až 18 GHz 0 dBm až 17 dBm CMC 4,4 % 10 MHz až 9 GHz 17 dBm až 40 dBm CMC 4,4 % 9 GHz až 18 GHz 17 dBm až 40 dBm CMC 5,7 % TP11, TP23 Moc w.cz. / Mierniki i zrodla mocy w.cz. oraz analizatory widma, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urzadzenia badawcze, kontrolne i testowe oraz ich czesci Wzorcowanie – wielkosci elektryczne Pomiar watomierzem, 50 Ω 10 MHz do 1 GHz od -50 dBm do -20 dBm CMC 4,8 % 1 GHz do 9 GHz od -50 dBm do -20 dBm CMC 5,0 % 9 GHz do 18 GHz od -50 dBm do -20 dBm CMC 5,4 % 10 MHz do 1 GHz od -20 dBm do 0 dBm CMC 3,4 % 1 GHz do 9 GHz od -20 dBm do 0 dBm CMC 3,7 % 9 GHz do 18 GHz od -20 dBm do 0 dBm CMC 4,3 % 10 MHz do 1 GHz 0 dBm CMC 3,0 % 1 GHz do 9 GHz 0 dBm CMC 3,2 % 9 GHz do 18 GHz 0 dBm CMC 3,8 % 10 MHz do 30 MHz od 0 dBm do 17 dBm CMC 6,5 % 30 MHz do 9 GHz od 0 dBm do 17 dBm CMC 4,1 % 9 GHz do 18 GHz od 0 dBm do 17 dBm CMC 4,4 % 10 MHz do 9 GHz od 17 dBm do 40 dBm CMC 4,4 % 9 GHz do 18 GHz od 17 dBm do 40 dBm CMC 5,7 % VF vykon / Meridla a zdroje VF vykonu a spektralni analyzatory, radiokomunikacni testery (COM, CMS, CTS...) a radionavigacni testery, simulatory a imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkusebni, kontrolni a testovaci zarizeni a jejich casti Kalibrace – elektricke veliciny Mereni wattmetrem, 50 Ω 10 MHz az 1 GHz -50 dBm az -20 dBm CMC 4,8 % 1 GHz az 9 GHz -50 dBm az -20 dBm CMC 5,0 % 9 GHz az 18 GHz -50 dBm az -20 dBm CMC 5,4 % 10 MHz az 1 GHz -20 dBm az 0 dBm CMC 3,4 % 1 GHz az 9 GHz -20 dBm az 0 dBm CMC 3,7 % 9 GHz az 18 GHz -20 dBm az 0 dBm CMC 4,3 % 10 MHz az 1 GHz 0 dBm CMC 3,0 % 1 GHz az 9 GHz 0 dBm CMC 3,2 % 9 GHz az 18 GHz 0 dBm CMC 3,8 % 10 MHz az 30 MHz 0 dBm az 17 dBm CMC 6,5 % 30 MHz az 9 GHz 0 dBm az 17 dBm CMC 4,1 % 9 GHz az 18 GHz 0 dBm az 17 dBm CMC 4,4 % 10 MHz az 9 GHz 17 dBm az 40 dBm CMC 4,4 % 9 GHz az 18 GHz 17 dBm az 40 dBm CMC 5,7 % TP11, TP23","search_en":"HF power / HF power meters and sources and spectrum analyzers, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts Calibration – electrical quantities Measurement by a wattmeter, 50 Ω 10 MHz to 1 GHz -50 dBm to -20 dBm CMC 4,8 % 1 GHz to 9 GHz -50 dBm to -20 dBm CMC 5,0 % 9 GHz to 18 GHz -50 dBm to -20 dBm CMC 5,4 % 10 MHz to 1 GHz -20 dBm to 0 dBm CMC 3,4 % 1 GHz to 9 GHz -20 dBm to 0 dBm CMC 3,7 % 9 GHz to 18 GHz -20 dBm to 0 dBm CMC 4,3 % 10 MHz to 1 GHz 0 dBm CMC 3,0 % 1 GHz to 9 GHz 0 dBm CMC 3,2 % 9 GHz to 18 GHz 0 dBm CMC 3,8 % 10 MHz to 30 MHz 0 dBm to 17 dBm CMC 6,5 % 30 MHz to 9 GHz 0 dBm to 17 dBm CMC 4,1 % 9 GHz to 18 GHz 0 dBm to 17 dBm CMC 4,4 % 10 MHz to 9 GHz 17 dBm to 40 dBm CMC 4,4 % 9 GHz to 18 GHz 17 dBm to 40 dBm CMC 5,7 % TP11, TP23","search_zh":"高频功率 / 高频功率计和功率源以及频谱分析仪、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件 校准 – 电学量 用功率计测量，50 Ω 10 MHz 至 1 GHz -50 dBm 至 -20 dBm CMC 4,8 % 1 GHz 至 9 GHz -50 dBm 至 -20 dBm CMC 5,0 % 9 GHz 至 18 GHz -50 dBm 至 -20 dBm CMC 5,4 % 10 MHz 至 1 GHz -20 dBm 至 0 dBm CMC 3,4 % 1 GHz 至 9 GHz -20 dBm 至 0 dBm CMC 3,7 % 9 GHz 至 18 GHz -20 dBm 至 0 dBm CMC 4,3 % 10 MHz 至 1 GHz 0 dBm CMC 3,0 % 1 GHz 至 9 GHz 0 dBm CMC 3,2 % 9 GHz 至 18 GHz 0 dBm CMC 3,8 % 10 MHz 至 30 MHz 0 dBm 至 17 dBm CMC 6,5 % 30 MHz 至 9 GHz 0 dBm 至 17 dBm CMC 4,1 % 9 GHz 至 18 GHz 0 dBm 至 17 dBm CMC 4,4 % 10 MHz 至 9 GHz 17 dBm 至 40 dBm CMC 4,4 % 9 GHz 至 18 GHz 17 dBm 至 40 dBm CMC 5,7 % TP11, TP23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f4a547924fcc873b6cab322a","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"12","test_object":"Napięcie w.cz., wartość międzyszczytowa / Mierniki napięcia w.cz., oscyloskopy","test_object_en":"HF voltage, peak-to-peak value / HF voltage meters, oscilloscopes","test_object_zh":"高频电压峰峰值 / 高频电压测量仪器、示波器","test_object_cs":"VF napětí, mezivrcholová hodnota / Měřidla VF napětí, osciloskopy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 kHz do 1 MHz","range":"od 5 mV do 3 V","cmc":"4,7 %"},{"name":"1 MHz do 10 MHz","range":"od 5 mV do 3 V","cmc":"6,6 %"},{"name":"10 MHz do 30 MHz","range":"od 5 mV do 3 V","cmc":"9,0 %"},{"name":"30 MHz do 250 MHz","range":"od 5 mV do 3 V","cmc":"6,8 %"},{"name":"50 kHz do 1 MHz","range":"od 3 V do 5,5 V","cmc":"4,7 %"},{"name":"1 MHz do 10 MHz","range":"od 3 V do 5,5 V","cmc":"6,6 %"},{"name":"10 MHz do 30 MHz","range":"od 3 V do 5,5 V","cmc":"9,0 %"},{"name":"30 MHz do 250 MHz","range":"od 3 V do 5,5 V","cmc":"6,8 %"},{"name":"250 MHz do 300 MHz","range":"od 3 V do 5,5 V","cmc":"6,8 %"}],"parameters_en":[{"name":"50 kHz to 1 MHz","range":"5 mV to 3 V","cmc":"4,7 %"},{"name":"1 MHz to 10 MHz","range":"5 mV to 3 V","cmc":"6,6 %"},{"name":"10 MHz to 30 MHz","range":"5 mV to 3 V","cmc":"9,0 %"},{"name":"30 MHz to 250 MHz","range":"5 mV to 3 V","cmc":"6,8 %"},{"name":"50 kHz to 1 MHz","range":"3 V to 5,5 V","cmc":"4,7 %"},{"name":"1 MHz to 10 MHz","range":"3 V to 5,5 V","cmc":"6,6 %"},{"name":"10 MHz to 30 MHz","range":"3 V to 5,5 V","cmc":"9,0 %"},{"name":"30 MHz to 250 MHz","range":"3 V to 5,5 V","cmc":"6,8 %"},{"name":"250 MHz to 300 MHz","range":"3 V to 5,5 V","cmc":"6,8 %"}],"parameters_zh":[{"name":"50 kHz 至 1 MHz","range":"5 mV 至 3 V","cmc":"4,7 %"},{"name":"1 MHz 至 10 MHz","range":"5 mV 至 3 V","cmc":"6,6 %"},{"name":"10 MHz 至 30 MHz","range":"5 mV 至 3 V","cmc":"9,0 %"},{"name":"30 MHz 至 250 MHz","range":"5 mV 至 3 V","cmc":"6,8 %"},{"name":"50 kHz 至 1 MHz","range":"3 V 至 5,5 V","cmc":"4,7 %"},{"name":"1 MHz 至 10 MHz","range":"3 V 至 5,5 V","cmc":"6,6 %"},{"name":"10 MHz 至 30 MHz","range":"3 V 至 5,5 V","cmc":"9,0 %"},{"name":"30 MHz 至 250 MHz","range":"3 V 至 5,5 V","cmc":"6,8 %"},{"name":"250 MHz 至 300 MHz","range":"3 V 至 5,5 V","cmc":"6,8 %"}],"parameters_cs":[{"name":"50 kHz až 1 MHz","range":"5 mV až 3 V","cmc":"4,7 %"},{"name":"1 MHz až 10 MHz","range":"5 mV až 3 V","cmc":"6,6 %"},{"name":"10 MHz až 30 MHz","range":"5 mV až 3 V","cmc":"9,0 %"},{"name":"30 MHz až 250 MHz","range":"5 mV až 3 V","cmc":"6,8 %"},{"name":"50 kHz až 1 MHz","range":"3 V až 5,5 V","cmc":"4,7 %"},{"name":"1 MHz až 10 MHz","range":"3 V až 5,5 V","cmc":"6,6 %"},{"name":"10 MHz až 30 MHz","range":"3 V až 5,5 V","cmc":"9,0 %"},{"name":"30 MHz až 250 MHz","range":"3 V až 5,5 V","cmc":"6,8 %"},{"name":"250 MHz až 300 MHz","range":"3 V až 5,5 V","cmc":"6,8 %"}],"technique":"Bezpośrednie generowanie kalibratorem, 50 Ω","technique_en":"Direct generation by a calibrator, 50 Ω","technique_zh":"用校准器直接产生，50 Ω","technique_cs":"Přímé generování kalibrátorem, 50 Ω","techniques":["Bezpośrednie generowanie kalibratorem, 50 Ω"],"techniques_en":["Direct generation by a calibrator, 50 Ω"],"techniques_zh":["用校准器直接产生，50 Ω"],"techniques_cs":["Přímé generování kalibrátorem, 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 kHz do 1 MHz od 5 mV do 3 V CMC 4,7 %\n1 MHz do 10 MHz od 5 mV do 3 V CMC 6,6 %\n10 MHz do 30 MHz od 5 mV do 3 V CMC 9,0 %\n30 MHz do 250 MHz od 5 mV do 3 V CMC 6,8 %\n50 kHz do 1 MHz od 3 V do 5,5 V CMC 4,7 %\n1 MHz do 10 MHz od 3 V do 5,5 V CMC 6,6 %\n10 MHz do 30 MHz od 3 V do 5,5 V CMC 9,0 %\n30 MHz do 250 MHz od 3 V do 5,5 V CMC 6,8 %\n250 MHz do 300 MHz od 3 V do 5,5 V CMC 6,8 %\nBezpośrednie generowanie kalibratorem, 50 Ω","reference":"TP12, TP23","norm_bases":["TP12","TP23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie w.cz., wartość międzyszczytowa / Mierniki napięcia w.cz., oscyloskopy Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem, 50 Ω 50 kHz do 1 MHz od 5 mV do 3 V CMC 4,7 % 1 MHz do 10 MHz od 5 mV do 3 V CMC 6,6 % 10 MHz do 30 MHz od 5 mV do 3 V CMC 9,0 % 30 MHz do 250 MHz od 5 mV do 3 V CMC 6,8 % 50 kHz do 1 MHz od 3 V do 5,5 V CMC 4,7 % 1 MHz do 10 MHz od 3 V do 5,5 V CMC 6,6 % 10 MHz do 30 MHz od 3 V do 5,5 V CMC 9,0 % 30 MHz do 250 MHz od 3 V do 5,5 V CMC 6,8 % 250 MHz do 300 MHz od 3 V do 5,5 V CMC 6,8 % VF napětí, mezivrcholová hodnota / Měřidla VF napětí, osciloskopy Kalibrace – elektrické veličiny Přímé generování kalibrátorem, 50 Ω 50 kHz až 1 MHz 5 mV až 3 V CMC 4,7 % 1 MHz až 10 MHz 5 mV až 3 V CMC 6,6 % 10 MHz až 30 MHz 5 mV až 3 V CMC 9,0 % 30 MHz až 250 MHz 5 mV až 3 V CMC 6,8 % 50 kHz až 1 MHz 3 V až 5,5 V CMC 4,7 % 1 MHz až 10 MHz 3 V až 5,5 V CMC 6,6 % 10 MHz až 30 MHz 3 V až 5,5 V CMC 9,0 % 30 MHz až 250 MHz 3 V až 5,5 V CMC 6,8 % 250 MHz až 300 MHz 3 V až 5,5 V CMC 6,8 % TP12, TP23 Napiecie w.cz., wartosc miedzyszczytowa / Mierniki napiecia w.cz., oscyloskopy Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem, 50 Ω 50 kHz do 1 MHz od 5 mV do 3 V CMC 4,7 % 1 MHz do 10 MHz od 5 mV do 3 V CMC 6,6 % 10 MHz do 30 MHz od 5 mV do 3 V CMC 9,0 % 30 MHz do 250 MHz od 5 mV do 3 V CMC 6,8 % 50 kHz do 1 MHz od 3 V do 5,5 V CMC 4,7 % 1 MHz do 10 MHz od 3 V do 5,5 V CMC 6,6 % 10 MHz do 30 MHz od 3 V do 5,5 V CMC 9,0 % 30 MHz do 250 MHz od 3 V do 5,5 V CMC 6,8 % 250 MHz do 300 MHz od 3 V do 5,5 V CMC 6,8 % VF napeti, mezivrcholova hodnota / Meridla VF napeti, osciloskopy Kalibrace – elektricke veliciny Prime generovani kalibratorem, 50 Ω 50 kHz az 1 MHz 5 mV az 3 V CMC 4,7 % 1 MHz az 10 MHz 5 mV az 3 V CMC 6,6 % 10 MHz az 30 MHz 5 mV az 3 V CMC 9,0 % 30 MHz az 250 MHz 5 mV az 3 V CMC 6,8 % 50 kHz az 1 MHz 3 V az 5,5 V CMC 4,7 % 1 MHz az 10 MHz 3 V az 5,5 V CMC 6,6 % 10 MHz az 30 MHz 3 V az 5,5 V CMC 9,0 % 30 MHz az 250 MHz 3 V az 5,5 V CMC 6,8 % 250 MHz az 300 MHz 3 V az 5,5 V CMC 6,8 % TP12, TP23","search_en":"HF voltage, peak-to-peak value / HF voltage meters, oscilloscopes Calibration – electrical quantities Direct generation by a calibrator, 50 Ω 50 kHz to 1 MHz 5 mV to 3 V CMC 4,7 % 1 MHz to 10 MHz 5 mV to 3 V CMC 6,6 % 10 MHz to 30 MHz 5 mV to 3 V CMC 9,0 % 30 MHz to 250 MHz 5 mV to 3 V CMC 6,8 % 50 kHz to 1 MHz 3 V to 5,5 V CMC 4,7 % 1 MHz to 10 MHz 3 V to 5,5 V CMC 6,6 % 10 MHz to 30 MHz 3 V to 5,5 V CMC 9,0 % 30 MHz to 250 MHz 3 V to 5,5 V CMC 6,8 % 250 MHz to 300 MHz 3 V to 5,5 V CMC 6,8 % TP12, TP23","search_zh":"高频电压峰峰值 / 高频电压测量仪器、示波器 校准 – 电学量 用校准器直接产生，50 Ω 50 kHz 至 1 MHz 5 mV 至 3 V CMC 4,7 % 1 MHz 至 10 MHz 5 mV 至 3 V CMC 6,6 % 10 MHz 至 30 MHz 5 mV 至 3 V CMC 9,0 % 30 MHz 至 250 MHz 5 mV 至 3 V CMC 6,8 % 50 kHz 至 1 MHz 3 V 至 5,5 V CMC 4,7 % 1 MHz 至 10 MHz 3 V 至 5,5 V CMC 6,6 % 10 MHz 至 30 MHz 3 V 至 5,5 V CMC 9,0 % 30 MHz 至 250 MHz 3 V 至 5,5 V CMC 6,8 % 250 MHz 至 300 MHz 3 V 至 5,5 V CMC 6,8 % TP12, TP23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ab299cdad36d51609f95cbaa","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"12","test_object":"Napięcie w.cz., wartość międzyszczytowa / Źródła napięcia w.cz.","test_object_en":"HF voltage, peak-to-peak value / HF voltage sources","test_object_zh":"高频电压峰峰值 / 高频电压源","test_object_cs":"VF napětí, mezivrcholová hodnota / Zdroje VF napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 MHz do 30 MHz","range":"od 20 mV do 1,5 V","cmc":"6,9 %"},{"name":"30 MHz do 100 MHz","range":"od 20 mV do 1,5 V","cmc":"4,7 %"},{"name":"100 MHz do 1 GHz","range":"od 20 mV do 1,5 V","cmc":"4,3 %"}],"parameters_en":[{"name":"20 MHz to 30 MHz","range":"20 mV to 1,5 V","cmc":"6,9 %"},{"name":"30 MHz to 100 MHz","range":"20 mV to 1,5 V","cmc":"4,7 %"},{"name":"100 MHz to 1 GHz","range":"20 mV to 1,5 V","cmc":"4,3 %"}],"parameters_zh":[{"name":"20 MHz 至 30 MHz","range":"20 mV 至 1,5 V","cmc":"6,9 %"},{"name":"30 MHz 至 100 MHz","range":"20 mV 至 1,5 V","cmc":"4,7 %"},{"name":"100 MHz 至 1 GHz","range":"20 mV 至 1,5 V","cmc":"4,3 %"}],"parameters_cs":[{"name":"20 MHz až 30 MHz","range":"20 mV až 1,5 V","cmc":"6,9 %"},{"name":"30 MHz až 100 MHz","range":"20 mV až 1,5 V","cmc":"4,7 %"},{"name":"100 MHz až 1 GHz","range":"20 mV až 1,5 V","cmc":"4,3 %"}],"technique":"Pomiar watomierzem, 50 Ω","technique_en":"Measurement by a wattmeter, 50 Ω","technique_zh":"用功率计测量，50 Ω","technique_cs":"Měření wattmetrem, 50 Ω","techniques":["Pomiar watomierzem, 50 Ω"],"techniques_en":["Measurement by a wattmeter, 50 Ω"],"techniques_zh":["用功率计测量，50 Ω"],"techniques_cs":["Měření wattmetrem, 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 MHz do 30 MHz od 20 mV do 1,5 V CMC 6,9 %\n30 MHz do 100 MHz od 20 mV do 1,5 V CMC 4,7 %\n100 MHz do 1 GHz od 20 mV do 1,5 V CMC 4,3 %\nPomiar watomierzem, 50 Ω","reference":"TP12","norm_bases":["TP12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie w.cz., wartość międzyszczytowa / Źródła napięcia w.cz. Wzorcowanie – wielkości elektryczne Pomiar watomierzem, 50 Ω 20 MHz do 30 MHz od 20 mV do 1,5 V CMC 6,9 % 30 MHz do 100 MHz od 20 mV do 1,5 V CMC 4,7 % 100 MHz do 1 GHz od 20 mV do 1,5 V CMC 4,3 % VF napětí, mezivrcholová hodnota / Zdroje VF napětí Kalibrace – elektrické veličiny Měření wattmetrem, 50 Ω 20 MHz až 30 MHz 20 mV až 1,5 V CMC 6,9 % 30 MHz až 100 MHz 20 mV až 1,5 V CMC 4,7 % 100 MHz až 1 GHz 20 mV až 1,5 V CMC 4,3 % TP12 Napiecie w.cz., wartosc miedzyszczytowa / Zrodla napiecia w.cz. Wzorcowanie – wielkosci elektryczne Pomiar watomierzem, 50 Ω 20 MHz do 30 MHz od 20 mV do 1,5 V CMC 6,9 % 30 MHz do 100 MHz od 20 mV do 1,5 V CMC 4,7 % 100 MHz do 1 GHz od 20 mV do 1,5 V CMC 4,3 % VF napeti, mezivrcholova hodnota / Zdroje VF napeti Kalibrace – elektricke veliciny Mereni wattmetrem, 50 Ω 20 MHz az 30 MHz 20 mV az 1,5 V CMC 6,9 % 30 MHz az 100 MHz 20 mV az 1,5 V CMC 4,7 % 100 MHz az 1 GHz 20 mV az 1,5 V CMC 4,3 % TP12","search_en":"HF voltage, peak-to-peak value / HF voltage sources Calibration – electrical quantities Measurement by a wattmeter, 50 Ω 20 MHz to 30 MHz 20 mV to 1,5 V CMC 6,9 % 30 MHz to 100 MHz 20 mV to 1,5 V CMC 4,7 % 100 MHz to 1 GHz 20 mV to 1,5 V CMC 4,3 % TP12","search_zh":"高频电压峰峰值 / 高频电压源 校准 – 电学量 用功率计测量，50 Ω 20 MHz 至 30 MHz 20 mV 至 1,5 V CMC 6,9 % 30 MHz 至 100 MHz 20 mV 至 1,5 V CMC 4,7 % 100 MHz 至 1 GHz 20 mV 至 1,5 V CMC 4,3 % TP12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4db5e8ee0278f554c0374296","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"12","test_object":"Napięcie w.cz., wartość międzyszczytowa / Źródła napięcia w.cz.","test_object_en":"HF voltage, peak-to-peak value / HF voltage sources","test_object_zh":"高频电压峰峰值 / 高频电压源","test_object_cs":"VF napětí, mezivrcholová hodnota / Zdroje VF napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 MHz do 10 MHz","range":"od 40 mV do 100 mV","cmc":"3,2 %"},{"name":"10 MHz do 20 MHz","range":"od 40 mV do 100 mV","cmc":"3,5 %"},{"name":"1 MHz do 10 MHz","range":"od 100 mV do 250 mV","cmc":"3,7 %"},{"name":"10 MHz do 20 MHz","range":"od 100 mV do 250 mV","cmc":"4,9 %"},{"name":"1 MHz do 10 MHz","range":"od 250 mV do 1 V","cmc":"2,5 %"},{"name":"10 MHz do 20 MHz","range":"od 250 mV do 1 V","cmc":"3,6 %"},{"name":"1 MHz do 10 MHz","range":"od 1 V do 1,5 V","cmc":"3,9 %"},{"name":"1 MHz do 10 MHz","range":"od 1,5 V do 3 V","cmc":"3,3 %"}],"parameters_en":[{"name":"1 MHz to 10 MHz","range":"40 mV to 100 mV","cmc":"3,2 %"},{"name":"10 MHz to 20 MHz","range":"40 mV to 100 mV","cmc":"3,5 %"},{"name":"1 MHz to 10 MHz","range":"100 mV to 250 mV","cmc":"3,7 %"},{"name":"10 MHz to 20 MHz","range":"100 mV to 250 mV","cmc":"4,9 %"},{"name":"1 MHz to 10 MHz","range":"250 mV to 1 V","cmc":"2,5 %"},{"name":"10 MHz to 20 MHz","range":"250 mV to 1 V","cmc":"3,6 %"},{"name":"1 MHz to 10 MHz","range":"1 V to 1,5 V","cmc":"3,9 %"},{"name":"1 MHz to 10 MHz","range":"1,5 V to 3 V","cmc":"3,3 %"}],"parameters_zh":[{"name":"1 MHz 至 10 MHz","range":"40 mV 至 100 mV","cmc":"3,2 %"},{"name":"10 MHz 至 20 MHz","range":"40 mV 至 100 mV","cmc":"3,5 %"},{"name":"1 MHz 至 10 MHz","range":"100 mV 至 250 mV","cmc":"3,7 %"},{"name":"10 MHz 至 20 MHz","range":"100 mV 至 250 mV","cmc":"4,9 %"},{"name":"1 MHz 至 10 MHz","range":"250 mV 至 1 V","cmc":"2,5 %"},{"name":"10 MHz 至 20 MHz","range":"250 mV 至 1 V","cmc":"3,6 %"},{"name":"1 MHz 至 10 MHz","range":"1 V 至 1,5 V","cmc":"3,9 %"},{"name":"1 MHz 至 10 MHz","range":"1,5 V 至 3 V","cmc":"3,3 %"}],"parameters_cs":[{"name":"1 MHz až 10 MHz","range":"40 mV až 100 mV","cmc":"3,2 %"},{"name":"10 MHz až 20 MHz","range":"40 mV až 100 mV","cmc":"3,5 %"},{"name":"1 MHz až 10 MHz","range":"100 mV až 250 mV","cmc":"3,7 %"},{"name":"10 MHz až 20 MHz","range":"100 mV až 250 mV","cmc":"4,9 %"},{"name":"1 MHz až 10 MHz","range":"250 mV až 1 V","cmc":"2,5 %"},{"name":"10 MHz až 20 MHz","range":"250 mV až 1 V","cmc":"3,6 %"},{"name":"1 MHz až 10 MHz","range":"1 V až 1,5 V","cmc":"3,9 %"},{"name":"1 MHz až 10 MHz","range":"1,5 V až 3 V","cmc":"3,3 %"}],"technique":"Pomiar woltomierzem w.cz., 50 Ω","technique_en":"Measurement by a HF voltmeter, 50 Ω","technique_zh":"用高频电压表测量，50 Ω","technique_cs":"Měření VF voltmetrem, 50 Ω","techniques":["Pomiar woltomierzem w.cz., 50 Ω"],"techniques_en":["Measurement by a HF voltmeter, 50 Ω"],"techniques_zh":["用高频电压表测量，50 Ω"],"techniques_cs":["Měření VF voltmetrem, 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 MHz do 10 MHz od 40 mV do 100 mV CMC 3,2 %\n10 MHz do 20 MHz od 40 mV do 100 mV CMC 3,5 %\n1 MHz do 10 MHz od 100 mV do 250 mV CMC 3,7 %\n10 MHz do 20 MHz od 100 mV do 250 mV CMC 4,9 %\n1 MHz do 10 MHz od 250 mV do 1 V CMC 2,5 %\n10 MHz do 20 MHz od 250 mV do 1 V CMC 3,6 %\n1 MHz do 10 MHz od 1 V do 1,5 V CMC 3,9 %\n1 MHz do 10 MHz od 1,5 V do 3 V CMC 3,3 %\nPomiar woltomierzem w.cz., 50 Ω","reference":"TP12","norm_bases":["TP12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie w.cz., wartość międzyszczytowa / Źródła napięcia w.cz. Wzorcowanie – wielkości elektryczne Pomiar woltomierzem w.cz., 50 Ω 1 MHz do 10 MHz od 40 mV do 100 mV CMC 3,2 % 10 MHz do 20 MHz od 40 mV do 100 mV CMC 3,5 % 1 MHz do 10 MHz od 100 mV do 250 mV CMC 3,7 % 10 MHz do 20 MHz od 100 mV do 250 mV CMC 4,9 % 1 MHz do 10 MHz od 250 mV do 1 V CMC 2,5 % 10 MHz do 20 MHz od 250 mV do 1 V CMC 3,6 % 1 MHz do 10 MHz od 1 V do 1,5 V CMC 3,9 % 1 MHz do 10 MHz od 1,5 V do 3 V CMC 3,3 % VF napětí, mezivrcholová hodnota / Zdroje VF napětí Kalibrace – elektrické veličiny Měření VF voltmetrem, 50 Ω 1 MHz až 10 MHz 40 mV až 100 mV CMC 3,2 % 10 MHz až 20 MHz 40 mV až 100 mV CMC 3,5 % 1 MHz až 10 MHz 100 mV až 250 mV CMC 3,7 % 10 MHz až 20 MHz 100 mV až 250 mV CMC 4,9 % 1 MHz až 10 MHz 250 mV až 1 V CMC 2,5 % 10 MHz až 20 MHz 250 mV až 1 V CMC 3,6 % 1 MHz až 10 MHz 1 V až 1,5 V CMC 3,9 % 1 MHz až 10 MHz 1,5 V až 3 V CMC 3,3 % TP12 Napiecie w.cz., wartosc miedzyszczytowa / Zrodla napiecia w.cz. Wzorcowanie – wielkosci elektryczne Pomiar woltomierzem w.cz., 50 Ω 1 MHz do 10 MHz od 40 mV do 100 mV CMC 3,2 % 10 MHz do 20 MHz od 40 mV do 100 mV CMC 3,5 % 1 MHz do 10 MHz od 100 mV do 250 mV CMC 3,7 % 10 MHz do 20 MHz od 100 mV do 250 mV CMC 4,9 % 1 MHz do 10 MHz od 250 mV do 1 V CMC 2,5 % 10 MHz do 20 MHz od 250 mV do 1 V CMC 3,6 % 1 MHz do 10 MHz od 1 V do 1,5 V CMC 3,9 % 1 MHz do 10 MHz od 1,5 V do 3 V CMC 3,3 % VF napeti, mezivrcholova hodnota / Zdroje VF napeti Kalibrace – elektricke veliciny Mereni VF voltmetrem, 50 Ω 1 MHz az 10 MHz 40 mV az 100 mV CMC 3,2 % 10 MHz az 20 MHz 40 mV az 100 mV CMC 3,5 % 1 MHz az 10 MHz 100 mV az 250 mV CMC 3,7 % 10 MHz az 20 MHz 100 mV az 250 mV CMC 4,9 % 1 MHz az 10 MHz 250 mV az 1 V CMC 2,5 % 10 MHz az 20 MHz 250 mV az 1 V CMC 3,6 % 1 MHz az 10 MHz 1 V az 1,5 V CMC 3,9 % 1 MHz az 10 MHz 1,5 V az 3 V CMC 3,3 % TP12","search_en":"HF voltage, peak-to-peak value / HF voltage sources Calibration – electrical quantities Measurement by a HF voltmeter, 50 Ω 1 MHz to 10 MHz 40 mV to 100 mV CMC 3,2 % 10 MHz to 20 MHz 40 mV to 100 mV CMC 3,5 % 1 MHz to 10 MHz 100 mV to 250 mV CMC 3,7 % 10 MHz to 20 MHz 100 mV to 250 mV CMC 4,9 % 1 MHz to 10 MHz 250 mV to 1 V CMC 2,5 % 10 MHz to 20 MHz 250 mV to 1 V CMC 3,6 % 1 MHz to 10 MHz 1 V to 1,5 V CMC 3,9 % 1 MHz to 10 MHz 1,5 V to 3 V CMC 3,3 % TP12","search_zh":"高频电压峰峰值 / 高频电压源 校准 – 电学量 用高频电压表测量，50 Ω 1 MHz 至 10 MHz 40 mV 至 100 mV CMC 3,2 % 10 MHz 至 20 MHz 40 mV 至 100 mV CMC 3,5 % 1 MHz 至 10 MHz 100 mV 至 250 mV CMC 3,7 % 10 MHz 至 20 MHz 100 mV 至 250 mV CMC 4,9 % 1 MHz 至 10 MHz 250 mV 至 1 V CMC 2,5 % 10 MHz 至 20 MHz 250 mV 至 1 V CMC 3,6 % 1 MHz 至 10 MHz 1 V 至 1,5 V CMC 3,9 % 1 MHz 至 10 MHz 1,5 V 至 3 V CMC 3,3 % TP12","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c7e31cee0bde8883439ca2e3","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"13","test_object":"Tłumienie w.cz. / Tłumiki w.cz.","test_object_en":"HF attenuation / HF attenuator","test_object_zh":"高频衰减 / 高频衰减器","test_object_cs":"VF zeslabení / VF zeslabovače","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1,2 GHz do 3,8 GHz","range":"od 0 dB do 60 dB","cmc":"0,30 dB"},{"name":"3,8 GHz do 8,2 GHz","range":"od 0 dB do 60 dB","cmc":"0,40 dB"},{"name":"8,2 GHz do 18 GHz","range":"od 0 dB do 60 dB","cmc":"0,70 dB"},{"name":"1,2 GHz do 3,8 GHz","range":"od 60 dB do 80 dB","cmc":"0,80 dB"},{"name":"3,8 GHz do 8,2 GHz","range":"od 60 dB do 80 dB","cmc":"1,2 dB"},{"name":"8,2 GHz do 18 GHz","range":"od 60 dB do 80 dB","cmc":"1,5 dB"}],"parameters_en":[{"name":"1,2 GHz to 3,8 GHz","range":"0 dB to 60 dB","cmc":"0,30 dB"},{"name":"3,8 GHz to 8,2 GHz","range":"0 dB to 60 dB","cmc":"0,40 dB"},{"name":"8,2 GHz to 18 GHz","range":"0 dB to 60 dB","cmc":"0,70 dB"},{"name":"1,2 GHz to 3,8 GHz","range":"60 dB to 80 dB","cmc":"0,80 dB"},{"name":"3,8 GHz to 8,2 GHz","range":"60 dB to 80 dB","cmc":"1,2 dB"},{"name":"8,2 GHz to 18 GHz","range":"60 dB to 80 dB","cmc":"1,5 dB"}],"parameters_zh":[{"name":"1,2 GHz 至 3,8 GHz","range":"0 dB 至 60 dB","cmc":"0,30 dB"},{"name":"3,8 GHz 至 8,2 GHz","range":"0 dB 至 60 dB","cmc":"0,40 dB"},{"name":"8,2 GHz 至 18 GHz","range":"0 dB 至 60 dB","cmc":"0,70 dB"},{"name":"1,2 GHz 至 3,8 GHz","range":"60 dB 至 80 dB","cmc":"0,80 dB"},{"name":"3,8 GHz 至 8,2 GHz","range":"60 dB 至 80 dB","cmc":"1,2 dB"},{"name":"8,2 GHz 至 18 GHz","range":"60 dB 至 80 dB","cmc":"1,5 dB"}],"parameters_cs":[{"name":"1,2 GHz až 3,8 GHz","range":"0 dB až 60 dB","cmc":"0,30 dB"},{"name":"3,8 GHz až 8,2 GHz","range":"0 dB až 60 dB","cmc":"0,40 dB"},{"name":"8,2 GHz až 18 GHz","range":"0 dB až 60 dB","cmc":"0,70 dB"},{"name":"1,2 GHz až 3,8 GHz","range":"60 dB až 80 dB","cmc":"0,80 dB"},{"name":"3,8 GHz až 8,2 GHz","range":"60 dB až 80 dB","cmc":"1,2 dB"},{"name":"8,2 GHz až 18 GHz","range":"60 dB až 80 dB","cmc":"1,5 dB"}],"technique":"Pomiar bezpośredni miernikiem tłumienia, metoda porównawcza","technique_en":"Direct measurement with attenuation meter, comparison method","technique_zh":"用衰减测量仪直接测量，比较法","technique_cs":"Přímé měření měřidlem útlumu, komparační metoda","techniques":["Pomiar bezpośredni miernikiem tłumienia, metoda porównawcza"],"techniques_en":["Direct measurement with attenuation meter, comparison method"],"techniques_zh":["用衰减测量仪直接测量，比较法"],"techniques_cs":["Přímé měření měřidlem útlumu, komparační metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1,2 GHz do 3,8 GHz od 0 dB do 60 dB CMC 0,30 dB\n3,8 GHz do 8,2 GHz od 0 dB do 60 dB CMC 0,40 dB\n8,2 GHz do 18 GHz od 0 dB do 60 dB CMC 0,70 dB\n1,2 GHz do 3,8 GHz od 60 dB do 80 dB CMC 0,80 dB\n3,8 GHz do 8,2 GHz od 60 dB do 80 dB CMC 1,2 dB\n8,2 GHz do 18 GHz od 60 dB do 80 dB CMC 1,5 dB\nPomiar bezpośredni miernikiem tłumienia, metoda porównawcza","reference":"TP13","norm_bases":["TP13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie w.cz. / Tłumiki w.cz. Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem tłumienia, metoda porównawcza 1,2 GHz do 3,8 GHz od 0 dB do 60 dB CMC 0,30 dB 3,8 GHz do 8,2 GHz od 0 dB do 60 dB CMC 0,40 dB 8,2 GHz do 18 GHz od 0 dB do 60 dB CMC 0,70 dB 1,2 GHz do 3,8 GHz od 60 dB do 80 dB CMC 0,80 dB 3,8 GHz do 8,2 GHz od 60 dB do 80 dB CMC 1,2 dB 8,2 GHz do 18 GHz od 60 dB do 80 dB CMC 1,5 dB VF zeslabení / VF zeslabovače Kalibrace – elektrické veličiny Přímé měření měřidlem útlumu, komparační metoda 1,2 GHz až 3,8 GHz 0 dB až 60 dB CMC 0,30 dB 3,8 GHz až 8,2 GHz 0 dB až 60 dB CMC 0,40 dB 8,2 GHz až 18 GHz 0 dB až 60 dB CMC 0,70 dB 1,2 GHz až 3,8 GHz 60 dB až 80 dB CMC 0,80 dB 3,8 GHz až 8,2 GHz 60 dB až 80 dB CMC 1,2 dB 8,2 GHz až 18 GHz 60 dB až 80 dB CMC 1,5 dB TP13 Tlumienie w.cz. / Tlumiki w.cz. Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem tlumienia, metoda porownawcza 1,2 GHz do 3,8 GHz od 0 dB do 60 dB CMC 0,30 dB 3,8 GHz do 8,2 GHz od 0 dB do 60 dB CMC 0,40 dB 8,2 GHz do 18 GHz od 0 dB do 60 dB CMC 0,70 dB 1,2 GHz do 3,8 GHz od 60 dB do 80 dB CMC 0,80 dB 3,8 GHz do 8,2 GHz od 60 dB do 80 dB CMC 1,2 dB 8,2 GHz do 18 GHz od 60 dB do 80 dB CMC 1,5 dB VF zeslabeni / VF zeslabovace Kalibrace – elektricke veliciny Prime mereni meridlem utlumu, komparacni metoda 1,2 GHz az 3,8 GHz 0 dB az 60 dB CMC 0,30 dB 3,8 GHz az 8,2 GHz 0 dB az 60 dB CMC 0,40 dB 8,2 GHz az 18 GHz 0 dB az 60 dB CMC 0,70 dB 1,2 GHz az 3,8 GHz 60 dB az 80 dB CMC 0,80 dB 3,8 GHz az 8,2 GHz 60 dB az 80 dB CMC 1,2 dB 8,2 GHz az 18 GHz 60 dB az 80 dB CMC 1,5 dB TP13","search_en":"HF attenuation / HF attenuator Calibration – electrical quantities Direct measurement with attenuation meter, comparison method 1,2 GHz to 3,8 GHz 0 dB to 60 dB CMC 0,30 dB 3,8 GHz to 8,2 GHz 0 dB to 60 dB CMC 0,40 dB 8,2 GHz to 18 GHz 0 dB to 60 dB CMC 0,70 dB 1,2 GHz to 3,8 GHz 60 dB to 80 dB CMC 0,80 dB 3,8 GHz to 8,2 GHz 60 dB to 80 dB CMC 1,2 dB 8,2 GHz to 18 GHz 60 dB to 80 dB CMC 1,5 dB TP13","search_zh":"高频衰减 / 高频衰减器 校准 – 电学量 用衰减测量仪直接测量，比较法 1,2 GHz 至 3,8 GHz 0 dB 至 60 dB CMC 0,30 dB 3,8 GHz 至 8,2 GHz 0 dB 至 60 dB CMC 0,40 dB 8,2 GHz 至 18 GHz 0 dB 至 60 dB CMC 0,70 dB 1,2 GHz 至 3,8 GHz 60 dB 至 80 dB CMC 0,80 dB 3,8 GHz 至 8,2 GHz 60 dB 至 80 dB CMC 1,2 dB 8,2 GHz 至 18 GHz 60 dB 至 80 dB CMC 1,5 dB TP13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7475d94e28277113a0eabee5","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"13","test_object":"Tłumienie w.cz. / Tłumiki w.cz. i mierniki tłumienia, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części","test_object_en":"HF attenuation / HF attenuators and attenuation meters, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts","test_object_zh":"高频衰减 / 高频衰减器和衰减测量仪器、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件","test_object_cs":"VF zeslabení / VF zeslabovače a měřidla zeslabení radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 MHz do 30 MHz","range":"od 0 dB do 30 dB","cmc":"0,50 dB"},{"name":"30 MHz do 2 GHz","range":"od 0 dB do 30 dB","cmc":"0,15 dB"},{"name":"2 GHz do 18 GHz","range":"od 0 dB do 30 dB","cmc":"0,35 dB"},{"name":"10 MHz do 30 MHz","range":"od 30 dB do 50 dB","cmc":"0,70 dB"},{"name":"30 MHz do 2 GHz","range":"od 30 dB do 50 dB","cmc":"0,35 dB"},{"name":"2 GHz do 18 GHz","range":"od 30 dB do 50 dB","cmc":"0,50 dB"}],"parameters_en":[{"name":"10 MHz to 30 MHz","range":"0 dB to 30 dB","cmc":"0,50 dB"},{"name":"30 MHz to 2 GHz","range":"0 dB to 30 dB","cmc":"0,15 dB"},{"name":"2 GHz to 18 GHz","range":"0 dB to 30 dB","cmc":"0,35 dB"},{"name":"10 MHz to 30 MHz","range":"30 dB to 50 dB","cmc":"0,70 dB"},{"name":"30 MHz to 2 GHz","range":"30 dB to 50 dB","cmc":"0,35 dB"},{"name":"2 GHz to 18 GHz","range":"30 dB to 50 dB","cmc":"0,50 dB"}],"parameters_zh":[{"name":"10 MHz 至 30 MHz","range":"0 dB 至 30 dB","cmc":"0,50 dB"},{"name":"30 MHz 至 2 GHz","range":"0 dB 至 30 dB","cmc":"0,15 dB"},{"name":"2 GHz 至 18 GHz","range":"0 dB 至 30 dB","cmc":"0,35 dB"},{"name":"10 MHz 至 30 MHz","range":"30 dB 至 50 dB","cmc":"0,70 dB"},{"name":"30 MHz 至 2 GHz","range":"30 dB 至 50 dB","cmc":"0,35 dB"},{"name":"2 GHz 至 18 GHz","range":"30 dB 至 50 dB","cmc":"0,50 dB"}],"parameters_cs":[{"name":"10 MHz až 30 MHz","range":"0 dB až 30 dB","cmc":"0,50 dB"},{"name":"30 MHz až 2 GHz","range":"0 dB až 30 dB","cmc":"0,15 dB"},{"name":"2 GHz až 18 GHz","range":"0 dB až 30 dB","cmc":"0,35 dB"},{"name":"10 MHz až 30 MHz","range":"30 dB až 50 dB","cmc":"0,70 dB"},{"name":"30 MHz až 2 GHz","range":"30 dB až 50 dB","cmc":"0,35 dB"},{"name":"2 GHz až 18 GHz","range":"30 dB až 50 dB","cmc":"0,50 dB"}],"technique":"Pomiar watomierzem, metoda mocy","technique_en":"Wattmeter measurement, power method","technique_zh":"用功率计测量，功率法","technique_cs":"Měření wattmetrem, výkonová metoda","techniques":["Pomiar watomierzem, metoda mocy"],"techniques_en":["Wattmeter measurement, power method"],"techniques_zh":["用功率计测量，功率法"],"techniques_cs":["Měření wattmetrem, výkonová metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 MHz do 30 MHz od 0 dB do 30 dB CMC 0,50 dB\n30 MHz do 2 GHz od 0 dB do 30 dB CMC 0,15 dB\n2 GHz do 18 GHz od 0 dB do 30 dB CMC 0,35 dB\n10 MHz do 30 MHz od 30 dB do 50 dB CMC 0,70 dB\n30 MHz do 2 GHz od 30 dB do 50 dB CMC 0,35 dB\n2 GHz do 18 GHz od 30 dB do 50 dB CMC 0,50 dB\nPomiar watomierzem, metoda mocy","reference":"TP13","norm_bases":["TP13"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie w.cz. / Tłumiki w.cz. i mierniki tłumienia, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części Wzorcowanie – wielkości elektryczne Pomiar watomierzem, metoda mocy 10 MHz do 30 MHz od 0 dB do 30 dB CMC 0,50 dB 30 MHz do 2 GHz od 0 dB do 30 dB CMC 0,15 dB 2 GHz do 18 GHz od 0 dB do 30 dB CMC 0,35 dB 10 MHz do 30 MHz od 30 dB do 50 dB CMC 0,70 dB 30 MHz do 2 GHz od 30 dB do 50 dB CMC 0,35 dB 2 GHz do 18 GHz od 30 dB do 50 dB CMC 0,50 dB VF zeslabení / VF zeslabovače a měřidla zeslabení radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části Kalibrace – elektrické veličiny Měření wattmetrem, výkonová metoda 10 MHz až 30 MHz 0 dB až 30 dB CMC 0,50 dB 30 MHz až 2 GHz 0 dB až 30 dB CMC 0,15 dB 2 GHz až 18 GHz 0 dB až 30 dB CMC 0,35 dB 10 MHz až 30 MHz 30 dB až 50 dB CMC 0,70 dB 30 MHz až 2 GHz 30 dB až 50 dB CMC 0,35 dB 2 GHz až 18 GHz 30 dB až 50 dB CMC 0,50 dB TP13 Tlumienie w.cz. / Tlumiki w.cz. i mierniki tlumienia, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urzadzenia badawcze, kontrolne i testowe oraz ich czesci Wzorcowanie – wielkosci elektryczne Pomiar watomierzem, metoda mocy 10 MHz do 30 MHz od 0 dB do 30 dB CMC 0,50 dB 30 MHz do 2 GHz od 0 dB do 30 dB CMC 0,15 dB 2 GHz do 18 GHz od 0 dB do 30 dB CMC 0,35 dB 10 MHz do 30 MHz od 30 dB do 50 dB CMC 0,70 dB 30 MHz do 2 GHz od 30 dB do 50 dB CMC 0,35 dB 2 GHz do 18 GHz od 30 dB do 50 dB CMC 0,50 dB VF zeslabeni / VF zeslabovace a meridla zeslabeni radiokomunikacni testery (COM, CMS, CTS...) a radionavigacni testery, simulatory a imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkusebni, kontrolni a testovaci zarizeni a jejich casti Kalibrace – elektricke veliciny Mereni wattmetrem, vykonova metoda 10 MHz az 30 MHz 0 dB az 30 dB CMC 0,50 dB 30 MHz az 2 GHz 0 dB az 30 dB CMC 0,15 dB 2 GHz az 18 GHz 0 dB az 30 dB CMC 0,35 dB 10 MHz az 30 MHz 30 dB az 50 dB CMC 0,70 dB 30 MHz az 2 GHz 30 dB az 50 dB CMC 0,35 dB 2 GHz az 18 GHz 30 dB az 50 dB CMC 0,50 dB TP13","search_en":"HF attenuation / HF attenuators and attenuation meters, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts Calibration – electrical quantities Wattmeter measurement, power method 10 MHz to 30 MHz 0 dB to 30 dB CMC 0,50 dB 30 MHz to 2 GHz 0 dB to 30 dB CMC 0,15 dB 2 GHz to 18 GHz 0 dB to 30 dB CMC 0,35 dB 10 MHz to 30 MHz 30 dB to 50 dB CMC 0,70 dB 30 MHz to 2 GHz 30 dB to 50 dB CMC 0,35 dB 2 GHz to 18 GHz 30 dB to 50 dB CMC 0,50 dB TP13","search_zh":"高频衰减 / 高频衰减器和衰减测量仪器、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件 校准 – 电学量 用功率计测量，功率法 10 MHz 至 30 MHz 0 dB 至 30 dB CMC 0,50 dB 30 MHz 至 2 GHz 0 dB 至 30 dB CMC 0,15 dB 2 GHz 至 18 GHz 0 dB 至 30 dB CMC 0,35 dB 10 MHz 至 30 MHz 30 dB 至 50 dB CMC 0,70 dB 30 MHz 至 2 GHz 30 dB 至 50 dB CMC 0,35 dB 2 GHz 至 18 GHz 30 dB 至 50 dB CMC 0,50 dB TP13","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1c37f2c75fe33a9cd93a0b8","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"14","test_object":"Głębokość AM / generatory sygnału modulowanego amplitudowo, mierniki modulacji amplitudy, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części","test_object_en":"Depth of AM / amplitude modulated signal generators, amplitude modulation meters, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts","test_object_zh":"调幅深度 / 调幅信号发生器、调幅测量仪器、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件","test_object_cs":"Hloubka AM / generátory amplitudově modulovaného signálu, měřidla amplitudové modulace, radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"fc 150 kHz do 10 MHz; fmod 20 Hz do 50 Hz","range":"od 5 % do 99 %","cmc":"3,2 % rel."},{"name":"fc 150 kHz do 10 MHz; fmod 50 Hz do 10 kHz","range":"od 5 % do 99 %","cmc":"2,2 % rel."},{"name":"fc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz","range":"od 5 % do 99 %","cmc":"3,2 % rel."},{"name":"fc 10 MHz do 1,3 GHz; fmod 50 Hz do 50 kHz","range":"od 5 % do 99 %","cmc":"1,2 % rel."},{"name":"fc 10 MHz do 1,3 GHz; fmod 50 kHz do 100 kHz","range":"od 5 % do 99 %","cmc":"3,2 % rel."}],"parameters_en":[{"name":"fc 150 kHz to 10 MHz; fmod 20 Hz to 50 Hz","range":"5 % to 99 %","cmc":"3,2 % rel."},{"name":"fc 150 kHz to 10 MHz; fmod 50 Hz to 10 kHz","range":"5 % to 99 %","cmc":"2,2 % rel."},{"name":"fc 10 MHz to 1,3 GHz; fmod 20 Hz to 50 Hz","range":"5 % to 99 %","cmc":"3,2 % rel."},{"name":"fc 10 MHz to 1,3 GHz; fmod 50 Hz to 50 kHz","range":"5 % to 99 %","cmc":"1,2 % rel."},{"name":"fc 10 MHz to 1,3 GHz; fmod 50 kHz to 100 kHz","range":"5 % to 99 %","cmc":"3,2 % rel."}],"parameters_zh":[{"name":"fc 150 kHz 至 10 MHz；fmod 20 Hz 至 50 Hz","range":"5 % 至 99 %","cmc":"3,2 % rel."},{"name":"fc 150 kHz 至 10 MHz；fmod 50 Hz 至 10 kHz","range":"5 % 至 99 %","cmc":"2,2 % rel."},{"name":"fc 10 MHz 至 1,3 GHz；fmod 20 Hz 至 50 Hz","range":"5 % 至 99 %","cmc":"3,2 % rel."},{"name":"fc 10 MHz 至 1,3 GHz；fmod 50 Hz 至 50 kHz","range":"5 % 至 99 %","cmc":"1,2 % rel."},{"name":"fc 10 MHz 至 1,3 GHz；fmod 50 kHz 至 100 kHz","range":"5 % 至 99 %","cmc":"3,2 % rel."}],"parameters_cs":[{"name":"fc 150 kHz až 10 MHz; fmod 20 Hz až 50 Hz","range":"5 % až 99 %","cmc":"3,2 % rel."},{"name":"fc 150 kHz až 10 MHz; fmod 50 Hz až 10 kHz","range":"5 % až 99 %","cmc":"2,2 % rel."},{"name":"fc 10 MHz až 1,3 GHz; fmod 20 Hz až 50 Hz","range":"5 % až 99 %","cmc":"3,2 % rel."},{"name":"fc 10 MHz až 1,3 GHz; fmod 50 Hz až 50 kHz","range":"5 % až 99 %","cmc":"1,2 % rel."},{"name":"fc 10 MHz až 1,3 GHz; fmod 50 kHz až 100 kHz","range":"5 % až 99 %","cmc":"3,2 % rel."}],"technique":"Pomiar bezpośredni miernikiem głębokości AM","technique_en":"Direct measurement by AM depth meter","technique_zh":"用调幅深度计直接测量","technique_cs":"Přímé měření měřidlem hloubky AM","techniques":["Pomiar bezpośredni miernikiem głębokości AM"],"techniques_en":["Direct measurement by AM depth meter"],"techniques_zh":["用调幅深度计直接测量"],"techniques_cs":["Přímé měření měřidlem hloubky AM"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nfc 150 kHz do 10 MHz; fmod 20 Hz do 50 Hz od 5 % do 99 % CMC 3,2 % rel.\nfc 150 kHz do 10 MHz; fmod 50 Hz do 10 kHz od 5 % do 99 % CMC 2,2 % rel.\nfc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz od 5 % do 99 % CMC 3,2 % rel.\nfc 10 MHz do 1,3 GHz; fmod 50 Hz do 50 kHz od 5 % do 99 % CMC 1,2 % rel.\nfc 10 MHz do 1,3 GHz; fmod 50 kHz do 100 kHz od 5 % do 99 % CMC 3,2 % rel.\nPomiar bezpośredni miernikiem głębokości AM","reference":"TP14","norm_bases":["TP14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Głębokość AM / generatory sygnału modulowanego amplitudowo, mierniki modulacji amplitudy, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem głębokości AM fc 150 kHz do 10 MHz; fmod 20 Hz do 50 Hz od 5 % do 99 % CMC 3,2 % rel. fc 150 kHz do 10 MHz; fmod 50 Hz do 10 kHz od 5 % do 99 % CMC 2,2 % rel. fc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz od 5 % do 99 % CMC 3,2 % rel. fc 10 MHz do 1,3 GHz; fmod 50 Hz do 50 kHz od 5 % do 99 % CMC 1,2 % rel. fc 10 MHz do 1,3 GHz; fmod 50 kHz do 100 kHz od 5 % do 99 % CMC 3,2 % rel. Hloubka AM / generátory amplitudově modulovaného signálu, měřidla amplitudové modulace, radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části Kalibrace – elektrické veličiny Přímé měření měřidlem hloubky AM fc 150 kHz až 10 MHz; fmod 20 Hz až 50 Hz 5 % až 99 % CMC 3,2 % rel. fc 150 kHz až 10 MHz; fmod 50 Hz až 10 kHz 5 % až 99 % CMC 2,2 % rel. fc 10 MHz až 1,3 GHz; fmod 20 Hz až 50 Hz 5 % až 99 % CMC 3,2 % rel. fc 10 MHz až 1,3 GHz; fmod 50 Hz až 50 kHz 5 % až 99 % CMC 1,2 % rel. fc 10 MHz až 1,3 GHz; fmod 50 kHz až 100 kHz 5 % až 99 % CMC 3,2 % rel. TP14 Glebokosc AM / generatory sygnalu modulowanego amplitudowo, mierniki modulacji amplitudy, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urzadzenia badawcze, kontrolne i testowe oraz ich czesci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem glebokosci AM fc 150 kHz do 10 MHz; fmod 20 Hz do 50 Hz od 5 % do 99 % CMC 3,2 % rel. fc 150 kHz do 10 MHz; fmod 50 Hz do 10 kHz od 5 % do 99 % CMC 2,2 % rel. fc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz od 5 % do 99 % CMC 3,2 % rel. fc 10 MHz do 1,3 GHz; fmod 50 Hz do 50 kHz od 5 % do 99 % CMC 1,2 % rel. fc 10 MHz do 1,3 GHz; fmod 50 kHz do 100 kHz od 5 % do 99 % CMC 3,2 % rel. Hloubka AM / generatory amplitudove modulovaneho signalu, meridla amplitudove modulace, radiokomunikacni testery (COM, CMS, CTS...) a radionavigacni testery, simulatory a imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkusebni, kontrolni a testovaci zarizeni a jejich casti Kalibrace – elektricke veliciny Prime mereni meridlem hloubky AM fc 150 kHz az 10 MHz; fmod 20 Hz az 50 Hz 5 % az 99 % CMC 3,2 % rel. fc 150 kHz az 10 MHz; fmod 50 Hz az 10 kHz 5 % az 99 % CMC 2,2 % rel. fc 10 MHz az 1,3 GHz; fmod 20 Hz az 50 Hz 5 % az 99 % CMC 3,2 % rel. fc 10 MHz az 1,3 GHz; fmod 50 Hz az 50 kHz 5 % az 99 % CMC 1,2 % rel. fc 10 MHz az 1,3 GHz; fmod 50 kHz az 100 kHz 5 % az 99 % CMC 3,2 % rel. TP14","search_en":"Depth of AM / amplitude modulated signal generators, amplitude modulation meters, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts Calibration – electrical quantities Direct measurement by AM depth meter fc 150 kHz to 10 MHz; fmod 20 Hz to 50 Hz 5 % to 99 % CMC 3,2 % rel. fc 150 kHz to 10 MHz; fmod 50 Hz to 10 kHz 5 % to 99 % CMC 2,2 % rel. fc 10 MHz to 1,3 GHz; fmod 20 Hz to 50 Hz 5 % to 99 % CMC 3,2 % rel. fc 10 MHz to 1,3 GHz; fmod 50 Hz to 50 kHz 5 % to 99 % CMC 1,2 % rel. fc 10 MHz to 1,3 GHz; fmod 50 kHz to 100 kHz 5 % to 99 % CMC 3,2 % rel. TP14","search_zh":"调幅深度 / 调幅信号发生器、调幅测量仪器、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件 校准 – 电学量 用调幅深度计直接测量 fc 150 kHz 至 10 MHz；fmod 20 Hz 至 50 Hz 5 % 至 99 % CMC 3,2 % rel. fc 150 kHz 至 10 MHz；fmod 50 Hz 至 10 kHz 5 % 至 99 % CMC 2,2 % rel. fc 10 MHz 至 1,3 GHz；fmod 20 Hz 至 50 Hz 5 % 至 99 % CMC 3,2 % rel. fc 10 MHz 至 1,3 GHz；fmod 50 Hz 至 50 kHz 5 % 至 99 % CMC 1,2 % rel. fc 10 MHz 至 1,3 GHz；fmod 50 kHz 至 100 kHz 5 % 至 99 % CMC 3,2 % rel. TP14","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"80da1138d528a6b2018c3b8e","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"15","test_object":"Dewiacja częstotliwości FM / generatory sygnału modulowanego częstotliwościowo, mierniki modulacji częstotliwości, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części","test_object_en":"FM frequency deviation / frequency modulated signal generators, frequency modulation meters, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts","test_object_zh":"调频频偏 / 调频信号发生器、调频测量仪器、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件","test_object_cs":"Kmitočtový zdvih FM / generátory frekvenčně modulovaného signálu, měřidla frekvenční modulace, radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"fc 150 kHz do 10 MHz; fmod 20 Hz do 10 kHz","range":"od 90 Hz do 40 kHz","cmc":"2,1 % + 1 Hz"},{"name":"fc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz","range":"od 90 Hz do 400 kHz","cmc":"5,1 % + 1 Hz"},{"name":"fc 10 MHz do 1,3 GHz; fmod 50 Hz do 100 kHz","range":"od 90 Hz do 400 kHz","cmc":"1,1 % + 1 Hz"},{"name":"fc 10 MHz do 1,3 GHz; fmod 100 kHz do 200 kHz","range":"od 90 Hz do 400 kHz","cmc":"5,1 % + 1 Hz"}],"parameters_en":[{"name":"fc 150 kHz to 10 MHz; fmod 20 Hz to 10 kHz","range":"90 Hz to 40 kHz","cmc":"2,1 % + 1 Hz"},{"name":"fc 10 MHz to 1,3 GHz; fmod 20 Hz to 50 Hz","range":"90 Hz to 400 kHz","cmc":"5,1 % + 1 Hz"},{"name":"fc 10 MHz to 1,3 GHz; fmod 50 Hz to 100 kHz","range":"90 Hz to 400 kHz","cmc":"1,1 % + 1 Hz"},{"name":"fc 10 MHz to 1,3 GHz; fmod 100 kHz to 200 kHz","range":"90 Hz to 400 kHz","cmc":"5,1 % + 1 Hz"}],"parameters_zh":[{"name":"fc 150 kHz 至 10 MHz；fmod 20 Hz 至 10 kHz","range":"90 Hz 至 40 kHz","cmc":"2,1 % + 1 Hz"},{"name":"fc 10 MHz 至 1,3 GHz；fmod 20 Hz 至 50 Hz","range":"90 Hz 至 400 kHz","cmc":"5,1 % + 1 Hz"},{"name":"fc 10 MHz 至 1,3 GHz；fmod 50 Hz 至 100 kHz","range":"90 Hz 至 400 kHz","cmc":"1,1 % + 1 Hz"},{"name":"fc 10 MHz 至 1,3 GHz；fmod 100 kHz 至 200 kHz","range":"90 Hz 至 400 kHz","cmc":"5,1 % + 1 Hz"}],"parameters_cs":[{"name":"fc 150 kHz až 10 MHz; fmod 20 Hz až 10 kHz","range":"90 Hz až 40 kHz","cmc":"2,1 % + 1 Hz"},{"name":"fc 10 MHz až 1,3 GHz; fmod 20 Hz až 50 Hz","range":"90 Hz až 400 kHz","cmc":"5,1 % + 1 Hz"},{"name":"fc 10 MHz až 1,3 GHz; fmod 50 Hz až 100 kHz","range":"90 Hz až 400 kHz","cmc":"1,1 % + 1 Hz"},{"name":"fc 10 MHz až 1,3 GHz; fmod 100 kHz až 200 kHz","range":"90 Hz až 400 kHz","cmc":"5,1 % + 1 Hz"}],"technique":"Pomiar bezpośredni miernikiem dewiacji częstotliwości FM","technique_en":"Direct measurement with a FM frequency deviation meter","technique_zh":"用调频频偏计直接测量","technique_cs":"Přímé měření měřidlem kmitočtového zdvihu FM","techniques":["Pomiar bezpośredni miernikiem dewiacji częstotliwości FM"],"techniques_en":["Direct measurement with a FM frequency deviation meter"],"techniques_zh":["用调频频偏计直接测量"],"techniques_cs":["Přímé měření měřidlem kmitočtového zdvihu FM"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nfc 150 kHz do 10 MHz; fmod 20 Hz do 10 kHz od 90 Hz do 40 kHz CMC 2,1 % + 1 Hz\nfc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz od 90 Hz do 400 kHz CMC 5,1 % + 1 Hz\nfc 10 MHz do 1,3 GHz; fmod 50 Hz do 100 kHz od 90 Hz do 400 kHz CMC 1,1 % + 1 Hz\nfc 10 MHz do 1,3 GHz; fmod 100 kHz do 200 kHz od 90 Hz do 400 kHz CMC 5,1 % + 1 Hz\nPomiar bezpośredni miernikiem dewiacji częstotliwości FM","reference":"—","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dewiacja częstotliwości FM / generatory sygnału modulowanego częstotliwościowo, mierniki modulacji częstotliwości, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urządzenia badawcze, kontrolne i testowe oraz ich części Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem dewiacji częstotliwości FM fc 150 kHz do 10 MHz; fmod 20 Hz do 10 kHz od 90 Hz do 40 kHz CMC 2,1 % + 1 Hz fc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz od 90 Hz do 400 kHz CMC 5,1 % + 1 Hz fc 10 MHz do 1,3 GHz; fmod 50 Hz do 100 kHz od 90 Hz do 400 kHz CMC 1,1 % + 1 Hz fc 10 MHz do 1,3 GHz; fmod 100 kHz do 200 kHz od 90 Hz do 400 kHz CMC 5,1 % + 1 Hz Kmitočtový zdvih FM / generátory frekvenčně modulovaného signálu, měřidla frekvenční modulace, radiokomunikační testery (COM, CMS, CTS...) a radionavigační testery, simulátory a imitátory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkušební, kontrolní a testovací zařízení a jejich části Kalibrace – elektrické veličiny Přímé měření měřidlem kmitočtového zdvihu FM fc 150 kHz až 10 MHz; fmod 20 Hz až 10 kHz 90 Hz až 40 kHz CMC 2,1 % + 1 Hz fc 10 MHz až 1,3 GHz; fmod 20 Hz až 50 Hz 90 Hz až 400 kHz CMC 5,1 % + 1 Hz fc 10 MHz až 1,3 GHz; fmod 50 Hz až 100 kHz 90 Hz až 400 kHz CMC 1,1 % + 1 Hz fc 10 MHz až 1,3 GHz; fmod 100 kHz až 200 kHz 90 Hz až 400 kHz CMC 5,1 % + 1 Hz — Dewiacja czestotliwosci FM / generatory sygnalu modulowanego czestotliwosciowo, mierniki modulacji czestotliwosci, testery radiokomunikacyjne (COM, CMS, CTS...) i testery radionawigacyjne, symulatory i imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), urzadzenia badawcze, kontrolne i testowe oraz ich czesci Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem dewiacji czestotliwosci FM fc 150 kHz do 10 MHz; fmod 20 Hz do 10 kHz od 90 Hz do 40 kHz CMC 2,1 % + 1 Hz fc 10 MHz do 1,3 GHz; fmod 20 Hz do 50 Hz od 90 Hz do 400 kHz CMC 5,1 % + 1 Hz fc 10 MHz do 1,3 GHz; fmod 50 Hz do 100 kHz od 90 Hz do 400 kHz CMC 1,1 % + 1 Hz fc 10 MHz do 1,3 GHz; fmod 100 kHz do 200 kHz od 90 Hz do 400 kHz CMC 5,1 % + 1 Hz Kmitoctovy zdvih FM / generatory frekvencne modulovaneho signalu, meridla frekvencni modulace, radiokomunikacni testery (COM, CMS, CTS...) a radionavigacni testery, simulatory a imitatory (ATC, DMF, TACAN, VOR– ILS, TCAS), zkusebni, kontrolni a testovaci zarizeni a jejich casti Kalibrace – elektricke veliciny Prime mereni meridlem kmitoctoveho zdvihu FM fc 150 kHz az 10 MHz; fmod 20 Hz az 10 kHz 90 Hz az 40 kHz CMC 2,1 % + 1 Hz fc 10 MHz az 1,3 GHz; fmod 20 Hz az 50 Hz 90 Hz az 400 kHz CMC 5,1 % + 1 Hz fc 10 MHz az 1,3 GHz; fmod 50 Hz az 100 kHz 90 Hz az 400 kHz CMC 1,1 % + 1 Hz fc 10 MHz az 1,3 GHz; fmod 100 kHz az 200 kHz 90 Hz az 400 kHz CMC 5,1 % + 1 Hz —","search_en":"FM frequency deviation / frequency modulated signal generators, frequency modulation meters, radio communication testers (COM, CMS, CTS...) and radio navigation testers, simulators and imitators (ATC, DMF, TACAN, VOR– ILS, TCAS), testing and inspection equipment and their parts Calibration – electrical quantities Direct measurement with a FM frequency deviation meter fc 150 kHz to 10 MHz; fmod 20 Hz to 10 kHz 90 Hz to 40 kHz CMC 2,1 % + 1 Hz fc 10 MHz to 1,3 GHz; fmod 20 Hz to 50 Hz 90 Hz to 400 kHz CMC 5,1 % + 1 Hz fc 10 MHz to 1,3 GHz; fmod 50 Hz to 100 kHz 90 Hz to 400 kHz CMC 1,1 % + 1 Hz fc 10 MHz to 1,3 GHz; fmod 100 kHz to 200 kHz 90 Hz to 400 kHz CMC 5,1 % + 1 Hz —","search_zh":"调频频偏 / 调频信号发生器、调频测量仪器、无线电通信测试仪（COM、CMS、CTS...）和无线电导航测试仪、模拟器和仿真器（ATC、DMF、TACAN、VOR– ILS、TCAS）、试验、检查和测试设备及其部件 校准 – 电学量 用调频频偏计直接测量 fc 150 kHz 至 10 MHz；fmod 20 Hz 至 10 kHz 90 Hz 至 40 kHz CMC 2,1 % + 1 Hz fc 10 MHz 至 1,3 GHz；fmod 20 Hz 至 50 Hz 90 Hz 至 400 kHz CMC 5,1 % + 1 Hz fc 10 MHz 至 1,3 GHz；fmod 50 Hz 至 100 kHz 90 Hz 至 400 kHz CMC 1,1 % + 1 Hz fc 10 MHz 至 1,3 GHz；fmod 100 kHz 至 200 kHz 90 Hz 至 400 kHz CMC 5,1 % + 1 Hz —","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f598876fa09344d2f7786efe","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"16","test_object":"Moc prądu stałego / Watomierze prądu stałego","test_object_en":"DC power / DC wattmeters","test_object_zh":"直流功率 / 直流功率计","test_object_cs":"Stejnosměrný výkon / Stejnosměrné wattmetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"33 mV do 10 V; 3,3 mA do 9 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"33 mV do 10 V; 9 mA do 33 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"33 mV do 10 V; 33 mA do 90 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"33 mV do 10 V; 90 mA do 330 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"33 mV do 10 V; 0,33 A do 0,9 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,08 %"},{"name":"33 mV do 10 V; 0,9 A do 2,2 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,06 %"},{"name":"33 mV do 10 V; 2,2 A do 4,5 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,12 %"},{"name":"33 mV do 10 V; 4,5 A do 11 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,09 %"},{"name":"10 V do 25 V; 3,3 mA do 9 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"10 V do 25 V; 9 mA do 33 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"10 V do 25 V; 33 mA do 90 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"10 V do 25 V; 90 mA do 330 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"10 V do 25 V; 0,33 A do 0,9 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,08 %"},{"name":"10 V do 25 V; 0,9 A do 2,2 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,06 %"},{"name":"10 V do 25 V; 2,2 A do 4,5 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,12 %"},{"name":"10 V do 25 V; 4,5 A do 11 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,09 %"},{"name":"10 V do 25 V; 11 A do 20 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,096 %"},{"name":"10 V do 25 V; 20 A do 30 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,079 %"},{"name":"10 V do 25 V; 30 A do 60 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,096 %"},{"name":"10 V do 25 V; 60 A do 90 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,079 %"},{"name":"25 V do 100 V; 3,3 mA do 9 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"25 V do 100 V; 9 mA do 33 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"25 V do 100 V; 33 mA do 50 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"25 V do 100 V; 50 mA do 100 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,013 %"},{"name":"25 V do 100 V; 100 mA do 330 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"25 V do 100 V; 0,33 A do 0,9 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,08 %"},{"name":"25 V do 100 V; 0,9 A do 2,2 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,06 %"},{"name":"25 V do 100 V; 2,2 A do 4,5 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,12 %"},{"name":"25 V do 100 V; 4,5 A do 11 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,09 %"},{"name":"25 V do 100 V; 11 A do 20 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,092 %"},{"name":"25 V do 100 V; 20 A do 30 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,075 %"},{"name":"25 V do 100 V; 30 A do 60 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,092 %"},{"name":"25 V do 100 V; 60 A do 90 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,075 %"},{"name":"100 V do 280 V; 3,3 mA do 9 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"100 V do 280 V; 9 mA do 33 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"100 V do 280 V; 33 mA do 90 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"100 V do 280 V; 90 mA do 330 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"100 V do 280 V; 0,33 A do 0,9 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,08 %"},{"name":"100 V do 280 V; 0,9 A do 2,2 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,06 %"},{"name":"100 V do 280 V; 2,2 A do 4,5 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,12 %"},{"name":"100 V do 280 V; 4,5 A do 11 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,09 %"},{"name":"100 V do 280 V; 11 A do 20 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,089 %"},{"name":"100 V do 280 V; 20 A do 30 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,073 %"},{"name":"100 V do 280 V; 30 A do 60 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,089 %"},{"name":"100 V do 280 V; 60 A do 90 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,073 %"},{"name":"280 V do 1000 V; 3,3 mA do 9 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"280 V do 1000 V; 9 mA do 33 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"280 V do 1000 V; 33 mA do 90 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,04 %"},{"name":"280 V do 1000 V; 90 mA do 330 mA","range":"od 0,1 mW do 25,2 kW","cmc":"0,03 %"},{"name":"280 V do 1000 V; 0,33 A do 0,9 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,08 %"},{"name":"280 V do 1000 V; 0,9 A do 2,2 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,06 %"},{"name":"280 V do 1000 V; 2,2 A do 4,5 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,12 %"},{"name":"280 V do 1000 V; 4,5 A do 11 A","range":"od 0,1 mW do 25,2 kW","cmc":"0,09 %"}],"parameters_en":[{"name":"33 mV to 10 V; 3,3 mA to 9 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"33 mV to 10 V; 9 mA to 33 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"33 mV to 10 V; 33 mA to 90 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"33 mV to 10 V; 90 mA to 330 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"33 mV to 10 V; 0,33 A to 0,9 A","range":"0,1 mW to 25,2 kW","cmc":"0,08 %"},{"name":"33 mV to 10 V; 0,9 A to 2,2 A","range":"0,1 mW to 25,2 kW","cmc":"0,06 %"},{"name":"33 mV to 10 V; 2,2 A to 4,5 A","range":"0,1 mW to 25,2 kW","cmc":"0,12 %"},{"name":"33 mV to 10 V; 4,5 A to 11 A","range":"0,1 mW to 25,2 kW","cmc":"0,09 %"},{"name":"10 V to 25 V; 3,3 mA to 9 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"10 V to 25 V; 9 mA to 33 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"10 V to 25 V; 33 mA to 90 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"10 V to 25 V; 90 mA to 330 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"10 V to 25 V; 0,33 A to 0,9 A","range":"0,1 mW to 25,2 kW","cmc":"0,08 %"},{"name":"10 V to 25 V; 0,9 A to 2,2 A","range":"0,1 mW to 25,2 kW","cmc":"0,06 %"},{"name":"10 V to 25 V; 2,2 A to 4,5 A","range":"0,1 mW to 25,2 kW","cmc":"0,12 %"},{"name":"10 V to 25 V; 4,5 A to 11 A","range":"0,1 mW to 25,2 kW","cmc":"0,09 %"},{"name":"10 V to 25 V; 11 A to 20 A","range":"0,1 mW to 25,2 kW","cmc":"0,096 %"},{"name":"10 V to 25 V; 20 A to 30 A","range":"0,1 mW to 25,2 kW","cmc":"0,079 %"},{"name":"10 V to 25 V; 30 A to 60 A","range":"0,1 mW to 25,2 kW","cmc":"0,096 %"},{"name":"10 V to 25 V; 60 A to 90 A","range":"0,1 mW to 25,2 kW","cmc":"0,079 %"},{"name":"25 V to 100 V; 3,3 mA to 9 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"25 V to 100 V; 9 mA to 33 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"25 V to 100 V; 33 mA to 50 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"25 V to 100 V; 50 mA to 100 mA","range":"0,1 mW to 25,2 kW","cmc":"0,013 %"},{"name":"25 V to 100 V; 100 mA to 330 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"25 V to 100 V; 0,33 A to 0,9 A","range":"0,1 mW to 25,2 kW","cmc":"0,08 %"},{"name":"25 V to 100 V; 0,9 A to 2,2 A","range":"0,1 mW to 25,2 kW","cmc":"0,06 %"},{"name":"25 V to 100 V; 2,2 A to 4,5 A","range":"0,1 mW to 25,2 kW","cmc":"0,12 %"},{"name":"25 V to 100 V; 4,5 A to 11 A","range":"0,1 mW to 25,2 kW","cmc":"0,09 %"},{"name":"25 V to 100 V; 11 A to 20 A","range":"0,1 mW to 25,2 kW","cmc":"0,092 %"},{"name":"25 V to 100 V; 20 A to 30 A","range":"0,1 mW to 25,2 kW","cmc":"0,075 %"},{"name":"25 V to 100 V; 30 A to 60 A","range":"0,1 mW to 25,2 kW","cmc":"0,092 %"},{"name":"25 V to 100 V; 60 A to 90 A","range":"0,1 mW to 25,2 kW","cmc":"0,075 %"},{"name":"100 V to 280 V; 3,3 mA to 9 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"100 V to 280 V; 9 mA to 33 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"100 V to 280 V; 33 mA to 90 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"100 V to 280 V; 90 mA to 330 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"100 V to 280 V; 0,33 A to 0,9 A","range":"0,1 mW to 25,2 kW","cmc":"0,08 %"},{"name":"100 V to 280 V; 0,9 A to 2,2 A","range":"0,1 mW to 25,2 kW","cmc":"0,06 %"},{"name":"100 V to 280 V; 2,2 A to 4,5 A","range":"0,1 mW to 25,2 kW","cmc":"0,12 %"},{"name":"100 V to 280 V; 4,5 A to 11 A","range":"0,1 mW to 25,2 kW","cmc":"0,09 %"},{"name":"100 V to 280 V; 11 A to 20 A","range":"0,1 mW to 25,2 kW","cmc":"0,089 %"},{"name":"100 V to 280 V; 20 A to 30 A","range":"0,1 mW to 25,2 kW","cmc":"0,073 %"},{"name":"100 V to 280 V; 30 A to 60 A","range":"0,1 mW to 25,2 kW","cmc":"0,089 %"},{"name":"100 V to 280 V; 60 A to 90 A","range":"0,1 mW to 25,2 kW","cmc":"0,073 %"},{"name":"280 V to 1000 V; 3,3 mA to 9 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"280 V to 1000 V; 9 mA to 33 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"280 V to 1000 V; 33 mA to 90 mA","range":"0,1 mW to 25,2 kW","cmc":"0,04 %"},{"name":"280 V to 1000 V; 90 mA to 330 mA","range":"0,1 mW to 25,2 kW","cmc":"0,03 %"},{"name":"280 V to 1000 V; 0,33 A to 0,9 A","range":"0,1 mW to 25,2 kW","cmc":"0,08 %"},{"name":"280 V to 1000 V; 0,9 A to 2,2 A","range":"0,1 mW to 25,2 kW","cmc":"0,06 %"},{"name":"280 V to 1000 V; 2,2 A to 4,5 A","range":"0,1 mW to 25,2 kW","cmc":"0,12 %"},{"name":"280 V to 1000 V; 4,5 A to 11 A","range":"0,1 mW to 25,2 kW","cmc":"0,09 %"}],"parameters_zh":[{"name":"33 mV 至 10 V；3,3 mA 至 9 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"33 mV 至 10 V；9 mA 至 33 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"33 mV 至 10 V；33 mA 至 90 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"33 mV 至 10 V；90 mA 至 330 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"33 mV 至 10 V；0,33 A 至 0,9 A","range":"0,1 mW 至 25,2 kW","cmc":"0,08 %"},{"name":"33 mV 至 10 V；0,9 A 至 2,2 A","range":"0,1 mW 至 25,2 kW","cmc":"0,06 %"},{"name":"33 mV 至 10 V；2,2 A 至 4,5 A","range":"0,1 mW 至 25,2 kW","cmc":"0,12 %"},{"name":"33 mV 至 10 V；4,5 A 至 11 A","range":"0,1 mW 至 25,2 kW","cmc":"0,09 %"},{"name":"10 V 至 25 V；3,3 mA 至 9 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"10 V 至 25 V；9 mA 至 33 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"10 V 至 25 V；33 mA 至 90 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"10 V 至 25 V；90 mA 至 330 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"10 V 至 25 V；0,33 A 至 0,9 A","range":"0,1 mW 至 25,2 kW","cmc":"0,08 %"},{"name":"10 V 至 25 V；0,9 A 至 2,2 A","range":"0,1 mW 至 25,2 kW","cmc":"0,06 %"},{"name":"10 V 至 25 V；2,2 A 至 4,5 A","range":"0,1 mW 至 25,2 kW","cmc":"0,12 %"},{"name":"10 V 至 25 V；4,5 A 至 11 A","range":"0,1 mW 至 25,2 kW","cmc":"0,09 %"},{"name":"10 V 至 25 V；11 A 至 20 A","range":"0,1 mW 至 25,2 kW","cmc":"0,096 %"},{"name":"10 V 至 25 V；20 A 至 30 A","range":"0,1 mW 至 25,2 kW","cmc":"0,079 %"},{"name":"10 V 至 25 V；30 A 至 60 A","range":"0,1 mW 至 25,2 kW","cmc":"0,096 %"},{"name":"10 V 至 25 V；60 A 至 90 A","range":"0,1 mW 至 25,2 kW","cmc":"0,079 %"},{"name":"25 V 至 100 V；3,3 mA 至 9 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"25 V 至 100 V；9 mA 至 33 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"25 V 至 100 V；33 mA 至 50 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"25 V 至 100 V；50 mA 至 100 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,013 %"},{"name":"25 V 至 100 V；100 mA 至 330 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"25 V 至 100 V；0,33 A 至 0,9 A","range":"0,1 mW 至 25,2 kW","cmc":"0,08 %"},{"name":"25 V 至 100 V；0,9 A 至 2,2 A","range":"0,1 mW 至 25,2 kW","cmc":"0,06 %"},{"name":"25 V 至 100 V；2,2 A 至 4,5 A","range":"0,1 mW 至 25,2 kW","cmc":"0,12 %"},{"name":"25 V 至 100 V；4,5 A 至 11 A","range":"0,1 mW 至 25,2 kW","cmc":"0,09 %"},{"name":"25 V 至 100 V；11 A 至 20 A","range":"0,1 mW 至 25,2 kW","cmc":"0,092 %"},{"name":"25 V 至 100 V；20 A 至 30 A","range":"0,1 mW 至 25,2 kW","cmc":"0,075 %"},{"name":"25 V 至 100 V；30 A 至 60 A","range":"0,1 mW 至 25,2 kW","cmc":"0,092 %"},{"name":"25 V 至 100 V；60 A 至 90 A","range":"0,1 mW 至 25,2 kW","cmc":"0,075 %"},{"name":"100 V 至 280 V；3,3 mA 至 9 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"100 V 至 280 V；9 mA 至 33 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"100 V 至 280 V；33 mA 至 90 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"100 V 至 280 V；90 mA 至 330 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"100 V 至 280 V；0,33 A 至 0,9 A","range":"0,1 mW 至 25,2 kW","cmc":"0,08 %"},{"name":"100 V 至 280 V；0,9 A 至 2,2 A","range":"0,1 mW 至 25,2 kW","cmc":"0,06 %"},{"name":"100 V 至 280 V；2,2 A 至 4,5 A","range":"0,1 mW 至 25,2 kW","cmc":"0,12 %"},{"name":"100 V 至 280 V；4,5 A 至 11 A","range":"0,1 mW 至 25,2 kW","cmc":"0,09 %"},{"name":"100 V 至 280 V；11 A 至 20 A","range":"0,1 mW 至 25,2 kW","cmc":"0,089 %"},{"name":"100 V 至 280 V；20 A 至 30 A","range":"0,1 mW 至 25,2 kW","cmc":"0,073 %"},{"name":"100 V 至 280 V；30 A 至 60 A","range":"0,1 mW 至 25,2 kW","cmc":"0,089 %"},{"name":"100 V 至 280 V；60 A 至 90 A","range":"0,1 mW 至 25,2 kW","cmc":"0,073 %"},{"name":"280 V 至 1000 V；3,3 mA 至 9 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"280 V 至 1000 V；9 mA 至 33 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"280 V 至 1000 V；33 mA 至 90 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,04 %"},{"name":"280 V 至 1000 V；90 mA 至 330 mA","range":"0,1 mW 至 25,2 kW","cmc":"0,03 %"},{"name":"280 V 至 1000 V；0,33 A 至 0,9 A","range":"0,1 mW 至 25,2 kW","cmc":"0,08 %"},{"name":"280 V 至 1000 V；0,9 A 至 2,2 A","range":"0,1 mW 至 25,2 kW","cmc":"0,06 %"},{"name":"280 V 至 1000 V；2,2 A 至 4,5 A","range":"0,1 mW 至 25,2 kW","cmc":"0,12 %"},{"name":"280 V 至 1000 V；4,5 A 至 11 A","range":"0,1 mW 至 25,2 kW","cmc":"0,09 %"}],"parameters_cs":[{"name":"33 mV až 10 V; 3,3 mA až 9 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"33 mV až 10 V; 9 mA až 33 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"33 mV až 10 V; 33 mA až 90 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"33 mV až 10 V; 90 mA až 330 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"33 mV až 10 V; 0,33 A až 0,9 A","range":"0,1 mW až 25,2 kW","cmc":"0,08 %"},{"name":"33 mV až 10 V; 0,9 A až 2,2 A","range":"0,1 mW až 25,2 kW","cmc":"0,06 %"},{"name":"33 mV až 10 V; 2,2 A až 4,5 A","range":"0,1 mW až 25,2 kW","cmc":"0,12 %"},{"name":"33 mV až 10 V; 4,5 A až 11 A","range":"0,1 mW až 25,2 kW","cmc":"0,09 %"},{"name":"10 V až 25 V; 3,3 mA až 9 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"10 V až 25 V; 9 mA až 33 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"10 V až 25 V; 33 mA až 90 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"10 V až 25 V; 90 mA až 330 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"10 V až 25 V; 0,33 A až 0,9 A","range":"0,1 mW až 25,2 kW","cmc":"0,08 %"},{"name":"10 V až 25 V; 0,9 A až 2,2 A","range":"0,1 mW až 25,2 kW","cmc":"0,06 %"},{"name":"10 V až 25 V; 2,2 A až 4,5 A","range":"0,1 mW až 25,2 kW","cmc":"0,12 %"},{"name":"10 V až 25 V; 4,5 A až 11 A","range":"0,1 mW až 25,2 kW","cmc":"0,09 %"},{"name":"10 V až 25 V; 11 A až 20 A","range":"0,1 mW až 25,2 kW","cmc":"0,096 %"},{"name":"10 V až 25 V; 20 A až 30 A","range":"0,1 mW až 25,2 kW","cmc":"0,079 %"},{"name":"10 V až 25 V; 30 A až 60 A","range":"0,1 mW až 25,2 kW","cmc":"0,096 %"},{"name":"10 V až 25 V; 60 A až 90 A","range":"0,1 mW až 25,2 kW","cmc":"0,079 %"},{"name":"25 V až 100 V; 3,3 mA až 9 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"25 V až 100 V; 9 mA až 33 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"25 V až 100 V; 33 mA až 50 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"25 V až 100 V; 50 mA až 100 mA","range":"0,1 mW až 25,2 kW","cmc":"0,013 %"},{"name":"25 V až 100 V; 100 mA až 330 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"25 V až 100 V; 0,33 A až 0,9 A","range":"0,1 mW až 25,2 kW","cmc":"0,08 %"},{"name":"25 V až 100 V; 0,9 A až 2,2 A","range":"0,1 mW až 25,2 kW","cmc":"0,06 %"},{"name":"25 V až 100 V; 2,2 A až 4,5 A","range":"0,1 mW až 25,2 kW","cmc":"0,12 %"},{"name":"25 V až 100 V; 4,5 A až 11 A","range":"0,1 mW až 25,2 kW","cmc":"0,09 %"},{"name":"25 V až 100 V; 11 A až 20 A","range":"0,1 mW až 25,2 kW","cmc":"0,092 %"},{"name":"25 V až 100 V; 20 A až 30 A","range":"0,1 mW až 25,2 kW","cmc":"0,075 %"},{"name":"25 V až 100 V; 30 A až 60 A","range":"0,1 mW až 25,2 kW","cmc":"0,092 %"},{"name":"25 V až 100 V; 60 A až 90 A","range":"0,1 mW až 25,2 kW","cmc":"0,075 %"},{"name":"100 V až 280 V; 3,3 mA až 9 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"100 V až 280 V; 9 mA až 33 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"100 V až 280 V; 33 mA až 90 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"100 V až 280 V; 90 mA až 330 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"100 V až 280 V; 0,33 A až 0,9 A","range":"0,1 mW až 25,2 kW","cmc":"0,08 %"},{"name":"100 V až 280 V; 0,9 A až 2,2 A","range":"0,1 mW až 25,2 kW","cmc":"0,06 %"},{"name":"100 V až 280 V; 2,2 A až 4,5 A","range":"0,1 mW až 25,2 kW","cmc":"0,12 %"},{"name":"100 V až 280 V; 4,5 A až 11 A","range":"0,1 mW až 25,2 kW","cmc":"0,09 %"},{"name":"100 V až 280 V; 11 A až 20 A","range":"0,1 mW až 25,2 kW","cmc":"0,089 %"},{"name":"100 V až 280 V; 20 A až 30 A","range":"0,1 mW až 25,2 kW","cmc":"0,073 %"},{"name":"100 V až 280 V; 30 A až 60 A","range":"0,1 mW až 25,2 kW","cmc":"0,089 %"},{"name":"100 V až 280 V; 60 A až 90 A","range":"0,1 mW až 25,2 kW","cmc":"0,073 %"},{"name":"280 V až 1000 V; 3,3 mA až 9 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"280 V až 1000 V; 9 mA až 33 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"280 V až 1000 V; 33 mA až 90 mA","range":"0,1 mW až 25,2 kW","cmc":"0,04 %"},{"name":"280 V až 1000 V; 90 mA až 330 mA","range":"0,1 mW až 25,2 kW","cmc":"0,03 %"},{"name":"280 V až 1000 V; 0,33 A až 0,9 A","range":"0,1 mW až 25,2 kW","cmc":"0,08 %"},{"name":"280 V až 1000 V; 0,9 A až 2,2 A","range":"0,1 mW až 25,2 kW","cmc":"0,06 %"},{"name":"280 V až 1000 V; 2,2 A až 4,5 A","range":"0,1 mW až 25,2 kW","cmc":"0,12 %"},{"name":"280 V až 1000 V; 4,5 A až 11 A","range":"0,1 mW až 25,2 kW","cmc":"0,09 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n33 mV do 10 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n33 mV do 10 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n33 mV do 10 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n33 mV do 10 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n33 mV do 10 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 %\n33 mV do 10 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 %\n33 mV do 10 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 %\n33 mV do 10 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 %\n10 V do 25 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n10 V do 25 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n10 V do 25 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n10 V do 25 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n10 V do 25 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 %\n10 V do 25 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 %\n10 V do 25 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 %\n10 V do 25 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 %\n10 V do 25 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,096 %\n10 V do 25 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,079 %\n10 V do 25 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,096 %\n10 V do 25 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,079 %\n25 V do 100 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n25 V do 100 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n25 V do 100 V; 33 mA do 50 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n25 V do 100 V; 50 mA do 100 mA od 0,1 mW do 25,2 kW CMC 0,013 %\n25 V do 100 V; 100 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n25 V do 100 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 %\n25 V do 100 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 %\n25 V do 100 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 %\n25 V do 100 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 %\n25 V do 100 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,092 %\n25 V do 100 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,075 %\n25 V do 100 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,092 %\n25 V do 100 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,075 %\n100 V do 280 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n100 V do 280 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n100 V do 280 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n100 V do 280 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n100 V do 280 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 %\n100 V do 280 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 %\n100 V do 280 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 %\n100 V do 280 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 %\n100 V do 280 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,089 %\n100 V do 280 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,073 %\n100 V do 280 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,089 %\n100 V do 280 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,073 %\n280 V do 1000 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n280 V do 1000 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n280 V do 1000 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 %\n280 V do 1000 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 %\n280 V do 1000 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 %\n280 V do 1000 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 %\n280 V do 1000 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 %\n280 V do 1000 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / Watomierze prądu stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 33 mV do 10 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 33 mV do 10 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 33 mV do 10 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 33 mV do 10 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 33 mV do 10 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 33 mV do 10 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 33 mV do 10 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 33 mV do 10 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 10 V do 25 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 10 V do 25 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 10 V do 25 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 10 V do 25 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 10 V do 25 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 10 V do 25 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 10 V do 25 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 10 V do 25 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 10 V do 25 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,096 % 10 V do 25 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,079 % 10 V do 25 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,096 % 10 V do 25 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,079 % 25 V do 100 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 25 V do 100 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 25 V do 100 V; 33 mA do 50 mA od 0,1 mW do 25,2 kW CMC 0,04 % 25 V do 100 V; 50 mA do 100 mA od 0,1 mW do 25,2 kW CMC 0,013 % 25 V do 100 V; 100 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 25 V do 100 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 25 V do 100 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 25 V do 100 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 25 V do 100 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 25 V do 100 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,092 % 25 V do 100 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,075 % 25 V do 100 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,092 % 25 V do 100 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,075 % 100 V do 280 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 100 V do 280 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 100 V do 280 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 100 V do 280 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 100 V do 280 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 100 V do 280 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 100 V do 280 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 100 V do 280 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 100 V do 280 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,089 % 100 V do 280 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,073 % 100 V do 280 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,089 % 100 V do 280 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,073 % 280 V do 1000 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 280 V do 1000 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 280 V do 1000 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 280 V do 1000 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 280 V do 1000 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 280 V do 1000 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 280 V do 1000 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 280 V do 1000 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % Stejnosměrný výkon / Stejnosměrné wattmetry Kalibrace – elektrické veličiny Přímé generování kalibrátorem 33 mV až 10 V; 3,3 mA až 9 mA 0,1 mW až 25,2 kW CMC 0,04 % 33 mV až 10 V; 9 mA až 33 mA 0,1 mW až 25,2 kW CMC 0,03 % 33 mV až 10 V; 33 mA až 90 mA 0,1 mW až 25,2 kW CMC 0,04 % 33 mV až 10 V; 90 mA až 330 mA 0,1 mW až 25,2 kW CMC 0,03 % 33 mV až 10 V; 0,33 A až 0,9 A 0,1 mW až 25,2 kW CMC 0,08 % 33 mV až 10 V; 0,9 A až 2,2 A 0,1 mW až 25,2 kW CMC 0,06 % 33 mV až 10 V; 2,2 A až 4,5 A 0,1 mW až 25,2 kW CMC 0,12 % 33 mV až 10 V; 4,5 A až 11 A 0,1 mW až 25,2 kW CMC 0,09 % 10 V až 25 V; 3,3 mA až 9 mA 0,1 mW až 25,2 kW CMC 0,04 % 10 V až 25 V; 9 mA až 33 mA 0,1 mW až 25,2 kW CMC 0,03 % 10 V až 25 V; 33 mA až 90 mA 0,1 mW až 25,2 kW CMC 0,04 % 10 V až 25 V; 90 mA až 330 mA 0,1 mW až 25,2 kW CMC 0,03 % 10 V až 25 V; 0,33 A až 0,9 A 0,1 mW až 25,2 kW CMC 0,08 % 10 V až 25 V; 0,9 A až 2,2 A 0,1 mW až 25,2 kW CMC 0,06 % 10 V až 25 V; 2,2 A až 4,5 A 0,1 mW až 25,2 kW CMC 0,12 % 10 V až 25 V; 4,5 A až 11 A 0,1 mW až 25,2 kW CMC 0,09 % 10 V až 25 V; 11 A až 20 A 0,1 mW až 25,2 kW CMC 0,096 % 10 V až 25 V; 20 A až 30 A 0,1 mW až 25,2 kW CMC 0,079 % 10 V až 25 V; 30 A až 60 A 0,1 mW až 25,2 kW CMC 0,096 % 10 V až 25 V; 60 A až 90 A 0,1 mW až 25,2 kW CMC 0,079 % 25 V až 100 V; 3,3 mA až 9 mA 0,1 mW až 25,2 kW CMC 0,04 % 25 V až 100 V; 9 mA až 33 mA 0,1 mW až 25,2 kW CMC 0,03 % 25 V až 100 V; 33 mA až 50 mA 0,1 mW až 25,2 kW CMC 0,04 % 25 V až 100 V; 50 mA až 100 mA 0,1 mW až 25,2 kW CMC 0,013 % 25 V až 100 V; 100 mA až 330 mA 0,1 mW až 25,2 kW CMC 0,03 % 25 V až 100 V; 0,33 A až 0,9 A 0,1 mW až 25,2 kW CMC 0,08 % 25 V až 100 V; 0,9 A až 2,2 A 0,1 mW až 25,2 kW CMC 0,06 % 25 V až 100 V; 2,2 A až 4,5 A 0,1 mW až 25,2 kW CMC 0,12 % 25 V až 100 V; 4,5 A až 11 A 0,1 mW až 25,2 kW CMC 0,09 % 25 V až 100 V; 11 A až 20 A 0,1 mW až 25,2 kW CMC 0,092 % 25 V až 100 V; 20 A až 30 A 0,1 mW až 25,2 kW CMC 0,075 % 25 V až 100 V; 30 A až 60 A 0,1 mW až 25,2 kW CMC 0,092 % 25 V až 100 V; 60 A až 90 A 0,1 mW až 25,2 kW CMC 0,075 % 100 V až 280 V; 3,3 mA až 9 mA 0,1 mW až 25,2 kW CMC 0,04 % 100 V až 280 V; 9 mA až 33 mA 0,1 mW až 25,2 kW CMC 0,03 % 100 V až 280 V; 33 mA až 90 mA 0,1 mW až 25,2 kW CMC 0,04 % 100 V až 280 V; 90 mA až 330 mA 0,1 mW až 25,2 kW CMC 0,03 % 100 V až 280 V; 0,33 A až 0,9 A 0,1 mW až 25,2 kW CMC 0,08 % 100 V až 280 V; 0,9 A až 2,2 A 0,1 mW až 25,2 kW CMC 0,06 % 100 V až 280 V; 2,2 A až 4,5 A 0,1 mW až 25,2 kW CMC 0,12 % 100 V až 280 V; 4,5 A až 11 A 0,1 mW až 25,2 kW CMC 0,09 % 100 V až 280 V; 11 A až 20 A 0,1 mW až 25,2 kW CMC 0,089 % 100 V až 280 V; 20 A až 30 A 0,1 mW až 25,2 kW CMC 0,073 % 100 V až 280 V; 30 A až 60 A 0,1 mW až 25,2 kW CMC 0,089 % 100 V až 280 V; 60 A až 90 A 0,1 mW až 25,2 kW CMC 0,073 % 280 V až 1000 V; 3,3 mA až 9 mA 0,1 mW až 25,2 kW CMC 0,04 % 280 V až 1000 V; 9 mA až 33 mA 0,1 mW až 25,2 kW CMC 0,03 % 280 V až 1000 V; 33 mA až 90 mA 0,1 mW až 25,2 kW CMC 0,04 % 280 V až 1000 V; 90 mA až 330 mA 0,1 mW až 25,2 kW CMC 0,03 % 280 V až 1000 V; 0,33 A až 0,9 A 0,1 mW až 25,2 kW CMC 0,08 % 280 V až 1000 V; 0,9 A až 2,2 A 0,1 mW až 25,2 kW CMC 0,06 % 280 V až 1000 V; 2,2 A až 4,5 A 0,1 mW až 25,2 kW CMC 0,12 % 280 V až 1000 V; 4,5 A až 11 A 0,1 mW až 25,2 kW CMC 0,09 % TP16 Moc pradu stalego / Watomierze pradu stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 33 mV do 10 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 33 mV do 10 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 33 mV do 10 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 33 mV do 10 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 33 mV do 10 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 33 mV do 10 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 33 mV do 10 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 33 mV do 10 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 10 V do 25 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 10 V do 25 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 10 V do 25 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 10 V do 25 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 10 V do 25 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 10 V do 25 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 10 V do 25 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 10 V do 25 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 10 V do 25 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,096 % 10 V do 25 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,079 % 10 V do 25 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,096 % 10 V do 25 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,079 % 25 V do 100 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 25 V do 100 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 25 V do 100 V; 33 mA do 50 mA od 0,1 mW do 25,2 kW CMC 0,04 % 25 V do 100 V; 50 mA do 100 mA od 0,1 mW do 25,2 kW CMC 0,013 % 25 V do 100 V; 100 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 25 V do 100 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 25 V do 100 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 25 V do 100 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 25 V do 100 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 25 V do 100 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,092 % 25 V do 100 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,075 % 25 V do 100 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,092 % 25 V do 100 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,075 % 100 V do 280 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 100 V do 280 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 100 V do 280 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 100 V do 280 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 100 V do 280 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 100 V do 280 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 100 V do 280 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 100 V do 280 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % 100 V do 280 V; 11 A do 20 A od 0,1 mW do 25,2 kW CMC 0,089 % 100 V do 280 V; 20 A do 30 A od 0,1 mW do 25,2 kW CMC 0,073 % 100 V do 280 V; 30 A do 60 A od 0,1 mW do 25,2 kW CMC 0,089 % 100 V do 280 V; 60 A do 90 A od 0,1 mW do 25,2 kW CMC 0,073 % 280 V do 1000 V; 3,3 mA do 9 mA od 0,1 mW do 25,2 kW CMC 0,04 % 280 V do 1000 V; 9 mA do 33 mA od 0,1 mW do 25,2 kW CMC 0,03 % 280 V do 1000 V; 33 mA do 90 mA od 0,1 mW do 25,2 kW CMC 0,04 % 280 V do 1000 V; 90 mA do 330 mA od 0,1 mW do 25,2 kW CMC 0,03 % 280 V do 1000 V; 0,33 A do 0,9 A od 0,1 mW do 25,2 kW CMC 0,08 % 280 V do 1000 V; 0,9 A do 2,2 A od 0,1 mW do 25,2 kW CMC 0,06 % 280 V do 1000 V; 2,2 A do 4,5 A od 0,1 mW do 25,2 kW CMC 0,12 % 280 V do 1000 V; 4,5 A do 11 A od 0,1 mW do 25,2 kW CMC 0,09 % Stejnosmerny vykon / Stejnosmerne wattmetry Kalibrace – elektricke veliciny Prime generovani kalibratorem 33 mV az 10 V; 3,3 mA az 9 mA 0,1 mW az 25,2 kW CMC 0,04 % 33 mV az 10 V; 9 mA az 33 mA 0,1 mW az 25,2 kW CMC 0,03 % 33 mV az 10 V; 33 mA az 90 mA 0,1 mW az 25,2 kW CMC 0,04 % 33 mV az 10 V; 90 mA az 330 mA 0,1 mW az 25,2 kW CMC 0,03 % 33 mV az 10 V; 0,33 A az 0,9 A 0,1 mW az 25,2 kW CMC 0,08 % 33 mV az 10 V; 0,9 A az 2,2 A 0,1 mW az 25,2 kW CMC 0,06 % 33 mV az 10 V; 2,2 A az 4,5 A 0,1 mW az 25,2 kW CMC 0,12 % 33 mV az 10 V; 4,5 A az 11 A 0,1 mW az 25,2 kW CMC 0,09 % 10 V az 25 V; 3,3 mA az 9 mA 0,1 mW az 25,2 kW CMC 0,04 % 10 V az 25 V; 9 mA az 33 mA 0,1 mW az 25,2 kW CMC 0,03 % 10 V az 25 V; 33 mA az 90 mA 0,1 mW az 25,2 kW CMC 0,04 % 10 V az 25 V; 90 mA az 330 mA 0,1 mW az 25,2 kW CMC 0,03 % 10 V az 25 V; 0,33 A az 0,9 A 0,1 mW az 25,2 kW CMC 0,08 % 10 V az 25 V; 0,9 A az 2,2 A 0,1 mW az 25,2 kW CMC 0,06 % 10 V az 25 V; 2,2 A az 4,5 A 0,1 mW az 25,2 kW CMC 0,12 % 10 V az 25 V; 4,5 A az 11 A 0,1 mW az 25,2 kW CMC 0,09 % 10 V az 25 V; 11 A az 20 A 0,1 mW az 25,2 kW CMC 0,096 % 10 V az 25 V; 20 A az 30 A 0,1 mW az 25,2 kW CMC 0,079 % 10 V az 25 V; 30 A az 60 A 0,1 mW az 25,2 kW CMC 0,096 % 10 V az 25 V; 60 A az 90 A 0,1 mW az 25,2 kW CMC 0,079 % 25 V az 100 V; 3,3 mA az 9 mA 0,1 mW az 25,2 kW CMC 0,04 % 25 V az 100 V; 9 mA az 33 mA 0,1 mW az 25,2 kW CMC 0,03 % 25 V az 100 V; 33 mA az 50 mA 0,1 mW az 25,2 kW CMC 0,04 % 25 V az 100 V; 50 mA az 100 mA 0,1 mW az 25,2 kW CMC 0,013 % 25 V az 100 V; 100 mA az 330 mA 0,1 mW az 25,2 kW CMC 0,03 % 25 V az 100 V; 0,33 A az 0,9 A 0,1 mW az 25,2 kW CMC 0,08 % 25 V az 100 V; 0,9 A az 2,2 A 0,1 mW az 25,2 kW CMC 0,06 % 25 V az 100 V; 2,2 A az 4,5 A 0,1 mW az 25,2 kW CMC 0,12 % 25 V az 100 V; 4,5 A az 11 A 0,1 mW az 25,2 kW CMC 0,09 % 25 V az 100 V; 11 A az 20 A 0,1 mW az 25,2 kW CMC 0,092 % 25 V az 100 V; 20 A az 30 A 0,1 mW az 25,2 kW CMC 0,075 % 25 V az 100 V; 30 A az 60 A 0,1 mW az 25,2 kW CMC 0,092 % 25 V az 100 V; 60 A az 90 A 0,1 mW az 25,2 kW CMC 0,075 % 100 V az 280 V; 3,3 mA az 9 mA 0,1 mW az 25,2 kW CMC 0,04 % 100 V az 280 V; 9 mA az 33 mA 0,1 mW az 25,2 kW CMC 0,03 % 100 V az 280 V; 33 mA az 90 mA 0,1 mW az 25,2 kW CMC 0,04 % 100 V az 280 V; 90 mA az 330 mA 0,1 mW az 25,2 kW CMC 0,03 % 100 V az 280 V; 0,33 A az 0,9 A 0,1 mW az 25,2 kW CMC 0,08 % 100 V az 280 V; 0,9 A az 2,2 A 0,1 mW az 25,2 kW CMC 0,06 % 100 V az 280 V; 2,2 A az 4,5 A 0,1 mW az 25,2 kW CMC 0,12 % 100 V az 280 V; 4,5 A az 11 A 0,1 mW az 25,2 kW CMC 0,09 % 100 V az 280 V; 11 A az 20 A 0,1 mW az 25,2 kW CMC 0,089 % 100 V az 280 V; 20 A az 30 A 0,1 mW az 25,2 kW CMC 0,073 % 100 V az 280 V; 30 A az 60 A 0,1 mW az 25,2 kW CMC 0,089 % 100 V az 280 V; 60 A az 90 A 0,1 mW az 25,2 kW CMC 0,073 % 280 V az 1000 V; 3,3 mA az 9 mA 0,1 mW az 25,2 kW CMC 0,04 % 280 V az 1000 V; 9 mA az 33 mA 0,1 mW az 25,2 kW CMC 0,03 % 280 V az 1000 V; 33 mA az 90 mA 0,1 mW az 25,2 kW CMC 0,04 % 280 V az 1000 V; 90 mA az 330 mA 0,1 mW az 25,2 kW CMC 0,03 % 280 V az 1000 V; 0,33 A az 0,9 A 0,1 mW az 25,2 kW CMC 0,08 % 280 V az 1000 V; 0,9 A az 2,2 A 0,1 mW az 25,2 kW CMC 0,06 % 280 V az 1000 V; 2,2 A az 4,5 A 0,1 mW az 25,2 kW CMC 0,12 % 280 V az 1000 V; 4,5 A az 11 A 0,1 mW az 25,2 kW CMC 0,09 % TP16","search_en":"DC power / DC wattmeters Calibration – electrical quantities Direct generation with a calibrator 33 mV to 10 V; 3,3 mA to 9 mA 0,1 mW to 25,2 kW CMC 0,04 % 33 mV to 10 V; 9 mA to 33 mA 0,1 mW to 25,2 kW CMC 0,03 % 33 mV to 10 V; 33 mA to 90 mA 0,1 mW to 25,2 kW CMC 0,04 % 33 mV to 10 V; 90 mA to 330 mA 0,1 mW to 25,2 kW CMC 0,03 % 33 mV to 10 V; 0,33 A to 0,9 A 0,1 mW to 25,2 kW CMC 0,08 % 33 mV to 10 V; 0,9 A to 2,2 A 0,1 mW to 25,2 kW CMC 0,06 % 33 mV to 10 V; 2,2 A to 4,5 A 0,1 mW to 25,2 kW CMC 0,12 % 33 mV to 10 V; 4,5 A to 11 A 0,1 mW to 25,2 kW CMC 0,09 % 10 V to 25 V; 3,3 mA to 9 mA 0,1 mW to 25,2 kW CMC 0,04 % 10 V to 25 V; 9 mA to 33 mA 0,1 mW to 25,2 kW CMC 0,03 % 10 V to 25 V; 33 mA to 90 mA 0,1 mW to 25,2 kW CMC 0,04 % 10 V to 25 V; 90 mA to 330 mA 0,1 mW to 25,2 kW CMC 0,03 % 10 V to 25 V; 0,33 A to 0,9 A 0,1 mW to 25,2 kW CMC 0,08 % 10 V to 25 V; 0,9 A to 2,2 A 0,1 mW to 25,2 kW CMC 0,06 % 10 V to 25 V; 2,2 A to 4,5 A 0,1 mW to 25,2 kW CMC 0,12 % 10 V to 25 V; 4,5 A to 11 A 0,1 mW to 25,2 kW CMC 0,09 % 10 V to 25 V; 11 A to 20 A 0,1 mW to 25,2 kW CMC 0,096 % 10 V to 25 V; 20 A to 30 A 0,1 mW to 25,2 kW CMC 0,079 % 10 V to 25 V; 30 A to 60 A 0,1 mW to 25,2 kW CMC 0,096 % 10 V to 25 V; 60 A to 90 A 0,1 mW to 25,2 kW CMC 0,079 % 25 V to 100 V; 3,3 mA to 9 mA 0,1 mW to 25,2 kW CMC 0,04 % 25 V to 100 V; 9 mA to 33 mA 0,1 mW to 25,2 kW CMC 0,03 % 25 V to 100 V; 33 mA to 50 mA 0,1 mW to 25,2 kW CMC 0,04 % 25 V to 100 V; 50 mA to 100 mA 0,1 mW to 25,2 kW CMC 0,013 % 25 V to 100 V; 100 mA to 330 mA 0,1 mW to 25,2 kW CMC 0,03 % 25 V to 100 V; 0,33 A to 0,9 A 0,1 mW to 25,2 kW CMC 0,08 % 25 V to 100 V; 0,9 A to 2,2 A 0,1 mW to 25,2 kW CMC 0,06 % 25 V to 100 V; 2,2 A to 4,5 A 0,1 mW to 25,2 kW CMC 0,12 % 25 V to 100 V; 4,5 A to 11 A 0,1 mW to 25,2 kW CMC 0,09 % 25 V to 100 V; 11 A to 20 A 0,1 mW to 25,2 kW CMC 0,092 % 25 V to 100 V; 20 A to 30 A 0,1 mW to 25,2 kW CMC 0,075 % 25 V to 100 V; 30 A to 60 A 0,1 mW to 25,2 kW CMC 0,092 % 25 V to 100 V; 60 A to 90 A 0,1 mW to 25,2 kW CMC 0,075 % 100 V to 280 V; 3,3 mA to 9 mA 0,1 mW to 25,2 kW CMC 0,04 % 100 V to 280 V; 9 mA to 33 mA 0,1 mW to 25,2 kW CMC 0,03 % 100 V to 280 V; 33 mA to 90 mA 0,1 mW to 25,2 kW CMC 0,04 % 100 V to 280 V; 90 mA to 330 mA 0,1 mW to 25,2 kW CMC 0,03 % 100 V to 280 V; 0,33 A to 0,9 A 0,1 mW to 25,2 kW CMC 0,08 % 100 V to 280 V; 0,9 A to 2,2 A 0,1 mW to 25,2 kW CMC 0,06 % 100 V to 280 V; 2,2 A to 4,5 A 0,1 mW to 25,2 kW CMC 0,12 % 100 V to 280 V; 4,5 A to 11 A 0,1 mW to 25,2 kW CMC 0,09 % 100 V to 280 V; 11 A to 20 A 0,1 mW to 25,2 kW CMC 0,089 % 100 V to 280 V; 20 A to 30 A 0,1 mW to 25,2 kW CMC 0,073 % 100 V to 280 V; 30 A to 60 A 0,1 mW to 25,2 kW CMC 0,089 % 100 V to 280 V; 60 A to 90 A 0,1 mW to 25,2 kW CMC 0,073 % 280 V to 1000 V; 3,3 mA to 9 mA 0,1 mW to 25,2 kW CMC 0,04 % 280 V to 1000 V; 9 mA to 33 mA 0,1 mW to 25,2 kW CMC 0,03 % 280 V to 1000 V; 33 mA to 90 mA 0,1 mW to 25,2 kW CMC 0,04 % 280 V to 1000 V; 90 mA to 330 mA 0,1 mW to 25,2 kW CMC 0,03 % 280 V to 1000 V; 0,33 A to 0,9 A 0,1 mW to 25,2 kW CMC 0,08 % 280 V to 1000 V; 0,9 A to 2,2 A 0,1 mW to 25,2 kW CMC 0,06 % 280 V to 1000 V; 2,2 A to 4,5 A 0,1 mW to 25,2 kW CMC 0,12 % 280 V to 1000 V; 4,5 A to 11 A 0,1 mW to 25,2 kW CMC 0,09 % TP16","search_zh":"直流功率 / 直流功率计 校准 – 电学量 用校准器直接产生 33 mV 至 10 V；3,3 mA 至 9 mA 0,1 mW 至 25,2 kW CMC 0,04 % 33 mV 至 10 V；9 mA 至 33 mA 0,1 mW 至 25,2 kW CMC 0,03 % 33 mV 至 10 V；33 mA 至 90 mA 0,1 mW 至 25,2 kW CMC 0,04 % 33 mV 至 10 V；90 mA 至 330 mA 0,1 mW 至 25,2 kW CMC 0,03 % 33 mV 至 10 V；0,33 A 至 0,9 A 0,1 mW 至 25,2 kW CMC 0,08 % 33 mV 至 10 V；0,9 A 至 2,2 A 0,1 mW 至 25,2 kW CMC 0,06 % 33 mV 至 10 V；2,2 A 至 4,5 A 0,1 mW 至 25,2 kW CMC 0,12 % 33 mV 至 10 V；4,5 A 至 11 A 0,1 mW 至 25,2 kW CMC 0,09 % 10 V 至 25 V；3,3 mA 至 9 mA 0,1 mW 至 25,2 kW CMC 0,04 % 10 V 至 25 V；9 mA 至 33 mA 0,1 mW 至 25,2 kW CMC 0,03 % 10 V 至 25 V；33 mA 至 90 mA 0,1 mW 至 25,2 kW CMC 0,04 % 10 V 至 25 V；90 mA 至 330 mA 0,1 mW 至 25,2 kW CMC 0,03 % 10 V 至 25 V；0,33 A 至 0,9 A 0,1 mW 至 25,2 kW CMC 0,08 % 10 V 至 25 V；0,9 A 至 2,2 A 0,1 mW 至 25,2 kW CMC 0,06 % 10 V 至 25 V；2,2 A 至 4,5 A 0,1 mW 至 25,2 kW CMC 0,12 % 10 V 至 25 V；4,5 A 至 11 A 0,1 mW 至 25,2 kW CMC 0,09 % 10 V 至 25 V；11 A 至 20 A 0,1 mW 至 25,2 kW CMC 0,096 % 10 V 至 25 V；20 A 至 30 A 0,1 mW 至 25,2 kW CMC 0,079 % 10 V 至 25 V；30 A 至 60 A 0,1 mW 至 25,2 kW CMC 0,096 % 10 V 至 25 V；60 A 至 90 A 0,1 mW 至 25,2 kW CMC 0,079 % 25 V 至 100 V；3,3 mA 至 9 mA 0,1 mW 至 25,2 kW CMC 0,04 % 25 V 至 100 V；9 mA 至 33 mA 0,1 mW 至 25,2 kW CMC 0,03 % 25 V 至 100 V；33 mA 至 50 mA 0,1 mW 至 25,2 kW CMC 0,04 % 25 V 至 100 V；50 mA 至 100 mA 0,1 mW 至 25,2 kW CMC 0,013 % 25 V 至 100 V；100 mA 至 330 mA 0,1 mW 至 25,2 kW CMC 0,03 % 25 V 至 100 V；0,33 A 至 0,9 A 0,1 mW 至 25,2 kW CMC 0,08 % 25 V 至 100 V；0,9 A 至 2,2 A 0,1 mW 至 25,2 kW CMC 0,06 % 25 V 至 100 V；2,2 A 至 4,5 A 0,1 mW 至 25,2 kW CMC 0,12 % 25 V 至 100 V；4,5 A 至 11 A 0,1 mW 至 25,2 kW CMC 0,09 % 25 V 至 100 V；11 A 至 20 A 0,1 mW 至 25,2 kW CMC 0,092 % 25 V 至 100 V；20 A 至 30 A 0,1 mW 至 25,2 kW CMC 0,075 % 25 V 至 100 V；30 A 至 60 A 0,1 mW 至 25,2 kW CMC 0,092 % 25 V 至 100 V；60 A 至 90 A 0,1 mW 至 25,2 kW CMC 0,075 % 100 V 至 280 V；3,3 mA 至 9 mA 0,1 mW 至 25,2 kW CMC 0,04 % 100 V 至 280 V；9 mA 至 33 mA 0,1 mW 至 25,2 kW CMC 0,03 % 100 V 至 280 V；33 mA 至 90 mA 0,1 mW 至 25,2 kW CMC 0,04 % 100 V 至 280 V；90 mA 至 330 mA 0,1 mW 至 25,2 kW CMC 0,03 % 100 V 至 280 V；0,33 A 至 0,9 A 0,1 mW 至 25,2 kW CMC 0,08 % 100 V 至 280 V；0,9 A 至 2,2 A 0,1 mW 至 25,2 kW CMC 0,06 % 100 V 至 280 V；2,2 A 至 4,5 A 0,1 mW 至 25,2 kW CMC 0,12 % 100 V 至 280 V；4,5 A 至 11 A 0,1 mW 至 25,2 kW CMC 0,09 % 100 V 至 280 V；11 A 至 20 A 0,1 mW 至 25,2 kW CMC 0,089 % 100 V 至 280 V；20 A 至 30 A 0,1 mW 至 25,2 kW CMC 0,073 % 100 V 至 280 V；30 A 至 60 A 0,1 mW 至 25,2 kW CMC 0,089 % 100 V 至 280 V；60 A 至 90 A 0,1 mW 至 25,2 kW CMC 0,073 % 280 V 至 1000 V；3,3 mA 至 9 mA 0,1 mW 至 25,2 kW CMC 0,04 % 280 V 至 1000 V；9 mA 至 33 mA 0,1 mW 至 25,2 kW CMC 0,03 % 280 V 至 1000 V；33 mA 至 90 mA 0,1 mW 至 25,2 kW CMC 0,04 % 280 V 至 1000 V；90 mA 至 330 mA 0,1 mW 至 25,2 kW CMC 0,03 % 280 V 至 1000 V；0,33 A 至 0,9 A 0,1 mW 至 25,2 kW CMC 0,08 % 280 V 至 1000 V；0,9 A 至 2,2 A 0,1 mW 至 25,2 kW CMC 0,06 % 280 V 至 1000 V；2,2 A 至 4,5 A 0,1 mW 至 25,2 kW CMC 0,12 % 280 V 至 1000 V；4,5 A 至 11 A 0,1 mW 至 25,2 kW CMC 0,09 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bea2557725ae011df362ba32","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"16","test_object":"Moc prądu stałego / Watomierze prądu stałego z cęgowymi czujnikami prądu","test_object_en":"DC power / DC wattmeters with clamp current sensors","test_object_zh":"直流功率 / 带钳形电流传感器的直流功率计","test_object_cs":"Stejnosměrný výkon / Stejnosměrné wattmetry s klešťovými snímači proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 V do 280 V; 90 A do 2250 A","range":"od 900 W do 630 kW","cmc":"0,50 %"}],"parameters_en":[{"name":"10 V to 280 V; 90 A to 2250 A","range":"900 W to 630 kW","cmc":"0,50 %"}],"parameters_zh":[{"name":"10 V 至 280 V；90 A 至 2250 A","range":"900 W 至 630 kW","cmc":"0,50 %"}],"parameters_cs":[{"name":"10 V až 280 V; 90 A až 2250 A","range":"900 W až 630 kW","cmc":"0,50 %"}],"technique":"Pośrednie generowanie kalibratorem z cewką prądową","technique_en":"Indirect generation with a calibrator with a current coil","technique_zh":"用带电流线圈的校准器间接产生","technique_cs":"Nepřímé generování kalibrátorem s proudovou cívkou","techniques":["Pośrednie generowanie kalibratorem z cewką prądową"],"techniques_en":["Indirect generation with a calibrator with a current coil"],"techniques_zh":["用带电流线圈的校准器间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n10 V do 280 V; 90 A do 2250 A od 900 W do 630 kW CMC 0,50 %\nPośrednie generowanie kalibratorem z cewką prądową","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / Watomierze prądu stałego z cęgowymi czujnikami prądu Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z cewką prądową 10 V do 280 V; 90 A do 2250 A od 900 W do 630 kW CMC 0,50 % Stejnosměrný výkon / Stejnosměrné wattmetry s klešťovými snímači proudu Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem s proudovou cívkou 10 V až 280 V; 90 A až 2250 A 900 W až 630 kW CMC 0,50 % TP16 Moc pradu stalego / Watomierze pradu stalego z cegowymi czujnikami pradu Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z cewka pradowa 10 V do 280 V; 90 A do 2250 A od 900 W do 630 kW CMC 0,50 % Stejnosmerny vykon / Stejnosmerne wattmetry s klestovymi snimaci proudu Kalibrace – elektricke veliciny Neprime generovani kalibratorem s proudovou civkou 10 V az 280 V; 90 A az 2250 A 900 W az 630 kW CMC 0,50 % TP16","search_en":"DC power / DC wattmeters with clamp current sensors Calibration – electrical quantities Indirect generation with a calibrator with a current coil 10 V to 280 V; 90 A to 2250 A 900 W to 630 kW CMC 0,50 % TP16","search_zh":"直流功率 / 带钳形电流传感器的直流功率计 校准 – 电学量 用带电流线圈的校准器间接产生 10 V 至 280 V；90 A 至 2250 A 900 W 至 630 kW CMC 0,50 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4efa73fb3a151568ec065a69","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"16","test_object":"Moc prądu stałego / Źródła","test_object_en":"DC power / Sources","test_object_zh":"直流功率 / 源","test_object_cs":"Stejnosměrný výkon / Zdroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 1000 V; 1 mA do 200 mA","range":"od 1 mW do 200 kW","cmc":"0,009 %"},{"name":"1 V do 1000 V; 200 mA do 200 A","range":"od 1 mW do 200 kW","cmc":"0,045 %"}],"parameters_en":[{"name":"1 V to 1000 V; 1 mA to 200 mA","range":"1 mW to 200 kW","cmc":"0,009 %"},{"name":"1 V to 1000 V; 200 mA to 200 A","range":"1 mW to 200 kW","cmc":"0,045 %"}],"parameters_zh":[{"name":"1 V 至 1000 V；1 mA 至 200 mA","range":"1 mW 至 200 kW","cmc":"0,009 %"},{"name":"1 V 至 1000 V；200 mA 至 200 A","range":"1 mW 至 200 kW","cmc":"0,045 %"}],"parameters_cs":[{"name":"1 V až 1000 V; 1 mA až 200 mA","range":"1 mW až 200 kW","cmc":"0,009 %"},{"name":"1 V až 1000 V; 200 mA až 200 A","range":"1 mW až 200 kW","cmc":"0,045 %"}],"technique":"Pomiar bezpośredni multimetrami i pomiar pośredni za pomocą bocznika prądowego","technique_en":"Direct measurement with multimeters or indirect measurement with a current shunt","technique_zh":"用万用表直接测量及借助电流分流器间接测量","technique_cs":"Přímé měření multimetry a nepřímé měření pomocí proudového bočníku","techniques":["Pomiar bezpośredni multimetrami i pomiar pośredni za pomocą bocznika prądowego"],"techniques_en":["Direct measurement with multimeters or indirect measurement with a current shunt"],"techniques_zh":["用万用表直接测量及借助电流分流器间接测量"],"techniques_cs":["Přímé měření multimetry a nepřímé měření pomocí proudového bočníku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 V do 1000 V; 1 mA do 200 mA od 1 mW do 200 kW CMC 0,009 %\n1 V do 1000 V; 200 mA do 200 A od 1 mW do 200 kW CMC 0,045 %\nPomiar bezpośredni multimetrami i pomiar pośredni za pomocą bocznika prądowego","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / Źródła Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrami i pomiar pośredni za pomocą bocznika prądowego 1 V do 1000 V; 1 mA do 200 mA od 1 mW do 200 kW CMC 0,009 % 1 V do 1000 V; 200 mA do 200 A od 1 mW do 200 kW CMC 0,045 % Stejnosměrný výkon / Zdroje Kalibrace – elektrické veličiny Přímé měření multimetry a nepřímé měření pomocí proudového bočníku 1 V až 1000 V; 1 mA až 200 mA 1 mW až 200 kW CMC 0,009 % 1 V až 1000 V; 200 mA až 200 A 1 mW až 200 kW CMC 0,045 % TP16 Moc pradu stalego / Zrodla Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrami i pomiar posredni za pomoca bocznika pradowego 1 V do 1000 V; 1 mA do 200 mA od 1 mW do 200 kW CMC 0,009 % 1 V do 1000 V; 200 mA do 200 A od 1 mW do 200 kW CMC 0,045 % Stejnosmerny vykon / Zdroje Kalibrace – elektricke veliciny Prime mereni multimetry a neprime mereni pomoci proudoveho bocniku 1 V az 1000 V; 1 mA az 200 mA 1 mW az 200 kW CMC 0,009 % 1 V az 1000 V; 200 mA az 200 A 1 mW az 200 kW CMC 0,045 % TP16","search_en":"DC power / Sources Calibration – electrical quantities Direct measurement with multimeters or indirect measurement with a current shunt 1 V to 1000 V; 1 mA to 200 mA 1 mW to 200 kW CMC 0,009 % 1 V to 1000 V; 200 mA to 200 A 1 mW to 200 kW CMC 0,045 % TP16","search_zh":"直流功率 / 源 校准 – 电学量 用万用表直接测量及借助电流分流器间接测量 1 V 至 1000 V；1 mA 至 200 mA 1 mW 至 200 kW CMC 0,009 % 1 V 至 1000 V；200 mA 至 200 A 1 mW 至 200 kW CMC 0,045 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d9ebd06c51a782fcb3b65836","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"17","test_object":"Moc czynna prądu przemiennego jednofazowa / Źródła (f: 45 Hz do 65 Hz, PF: 0 do 1)","test_object_en":"AC active power, single phase / Sources (f: 45 Hz to 65 Hz, PF: 0 to 1)","test_object_zh":"单相交流有功功率 / 源（f：45 Hz 至 65 Hz，PF：0 至 1）","test_object_cs":"Střídavý činný výkon jednofázový / Zdroje (f: 45 Hz až 65 Hz, PF: 0 až 1)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"25 V do 30 V; 150 mA do 200 mA","range":"od 0 W do 615 W","cmc":"0,90 mW/VA"},{"name":"25 V do 30 V; 200 mA do 300 mA","range":"od 0 W do 615 W","cmc":"0,72 mW/VA"},{"name":"25 V do 30 V; 300 mA do 400 mA","range":"od 0 W do 615 W","cmc":"0,90 mW/VA"},{"name":"25 V do 30 V; 400 mA do 600 mA","range":"od 0 W do 615 W","cmc":"0,72 mW/VA"},{"name":"25 V do 30 V; 600 mA do 800 mA","range":"od 0 W do 615 W","cmc":"0,90 mW/VA"},{"name":"25 V do 30 V; 800 mA do 1,3 A","range":"od 0 W do 615 W","cmc":"0,72 mW/VA"},{"name":"25 V do 30 V; 1,3 A do 2 A","range":"od 0 W do 615 W","cmc":"0,85 mW/VA"},{"name":"25 V do 30 V; 2 A do 2,6 A","range":"od 0 W do 615 W","cmc":"0,62 mW/VA"},{"name":"25 V do 30 V; 2,6 A do 4 A","range":"od 0 W do 615 W","cmc":"0,85 mW/VA"},{"name":"25 V do 30 V; 4 A do 5,2 A","range":"od 0 W do 615 W","cmc":"0,62 mW/VA"},{"name":"25 V do 30 V; 5,2 A do 8 A","range":"od 0 W do 615 W","cmc":"0,85 mW/VA"},{"name":"25 V do 30 V; 8 A do 10 A","range":"od 0 W do 615 W","cmc":"0,62 mW/VA"},{"name":"25 V do 30 V; 10 A do 15 A","range":"od 0 W do 615 W","cmc":"0,87 mW/VA"},{"name":"25 V do 30 V; 15 A do 20,5 A","range":"od 0 W do 615 W","cmc":"0,65 mW/VA"},{"name":"30 V do 50 V; 150 mA do 200 mA","range":"od 0 W do 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V do 50 V; 200 mA do 250 mA","range":"od 0 W do 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V do 50 V; 250 mA do 300 mA","range":"od 0 W do 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V do 50 V; 300 mA do 400 mA","range":"od 0 W do 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V do 50 V; 400 mA do 500 mA","range":"od 0 W do 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V do 50 V; 500 mA do 600 mA","range":"od 0 W do 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V do 50 V; 600 mA do 800 mA","range":"od 0 W do 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V do 50 V; 800 mA do 1 A","range":"od 0 W do 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V do 50 V; 1 A do 1,3 A","range":"od 0 W do 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V do 50 V; 1,3 A do 2 A","range":"od 0 W do 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V do 50 V; 2 A do 2,6 A","range":"od 0 W do 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V do 50 V; 2,6 A do 4 A","range":"od 0 W do 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V do 50 V; 4 A do 5,2 A","range":"od 0 W do 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V do 50 V; 5,2 A do 8 A","range":"od 0 W do 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V do 50 V; 8 A do 10 A","range":"od 0 W do 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V do 50 V; 10 A do 15 A","range":"od 0 W do 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V do 50 V; 15 A do 20,5 A","range":"od 0 W do 1,025 kW","cmc":"0,95 mW/VA"},{"name":"50 V do 60 V; 150 mA do 200 mA","range":"od 0 W do 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V do 60 V; 200 mA do 300 mA","range":"od 0 W do 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V do 60 V; 300 mA do 400 mA","range":"od 0 W do 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V do 60 V; 400 mA do 600 mA","range":"od 0 W do 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V do 60 V; 600 mA do 800 mA","range":"od 0 W do 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V do 60 V; 800 mA do 1,3 A","range":"od 0 W do 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V do 60 V; 1,3 A do 2 A","range":"od 0 W do 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V do 60 V; 2 A do 2,6 A","range":"od 0 W do 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V do 60 V; 2,6 A do 4 A","range":"od 0 W do 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V do 60 V; 4 A do 5,2 A","range":"od 0 W do 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V do 60 V; 5,2 A do 8 A","range":"od 0 W do 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V do 60 V; 8 A do 10 A","range":"od 0 W do 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V do 60 V; 10 A do 15 A","range":"od 0 W do 1,23 kW","cmc":"0,87 mW/VA"},{"name":"50 V do 60 V; 15 A do 20,5 A","range":"od 0 W do 1,23 kW","cmc":"0,65 mW/VA"},{"name":"60 V do 120 V; 150 mA do 200 mA","range":"od 0 W do 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V do 120 V; 200 mA do 250 mA","range":"od 0 W do 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V do 120 V; 250 mA do 300 mA","range":"od 0 W do 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V do 120 V; 300 mA do 400 mA","range":"od 0 W do 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V do 120 V; 400 mA do 500 mA","range":"od 0 W do 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V do 120 V; 500 mA do 600 mA","range":"od 0 W do 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V do 120 V; 600 mA do 800 mA","range":"od 0 W do 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V do 120 V; 800 mA do 1 A","range":"od 0 W do 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V do 120 V; 1 A do 1,3 A","range":"od 0 W do 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V do 120 V; 1,3 A do 2 A","range":"od 0 W do 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V do 120 V; 2 A do 2,6 A","range":"od 0 W do 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V do 120 V; 2,6 A do 4 A","range":"od 0 W do 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V do 120 V; 4 A do 5,2 A","range":"od 0 W do 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V do 120 V; 5,2 A do 8 A","range":"od 0 W do 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V do 120 V; 8 A do 10 A","range":"od 0 W do 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V do 120 V; 10 A do 15 A","range":"od 0 W do 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V do 120 V; 15 A do 20,5 A","range":"od 0 W do 2,46 kW","cmc":"0,95 mW/VA"},{"name":"120 V do 130 V; 150 mA do 200 mA","range":"od 0 W do 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V do 130 V; 200 mA do 300 mA","range":"od 0 W do 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V do 130 V; 300 mA do 400 mA","range":"od 0 W do 2,665 kW","cmc":"0,81 mW/VA"},{"name":"120 V do 130 V; 400 mA do 600 mA","range":"od 0 W do 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V do 130 V; 600 mA do 800 mA","range":"od 0 W do 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V do 130 V; 800 mA do 1 A","range":"od 0 W do 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V do 130 V; 1 A do 1,3 A","range":"od 0 W do 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V do 130 V; 1,3 A do 2 A","range":"od 0 W do 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V do 130 V; 2 A do 2,6 A","range":"od 0 W do 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V do 130 V; 2,6 A do 4 A","range":"od 0 W do 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V do 130 V; 4 A do 5,2 A","range":"od 0 W do 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V do 130 V; 5,2 A do 8 A","range":"od 0 W do 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V do 130 V; 8 A do 10 A","range":"od 0 W do 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V do 130 V; 10 A do 15 A","range":"od 0 W do 2,665 kW","cmc":"0,78 mW/VA"},{"name":"120 V do 130 V; 15 A do 20,5 A","range":"od 0 W do 2,665 kW","cmc":"0,59 mW/VA"},{"name":"130 V do 230 V; 150 mA do 200 mA","range":"od 0 W do 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V do 230 V; 200 mA do 250 mA","range":"od 0 W do 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V do 230 V; 250 mA do 300 mA","range":"od 0 W do 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V do 230 V; 300 mA do 400 mA","range":"od 0 W do 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V do 230 V; 400 mA do 500 mA","range":"od 0 W do 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V do 230 V; 500 mA do 600 mA","range":"od 0 W do 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V do 230 V; 600 mA do 800 mA","range":"od 0 W do 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V do 230 V; 800 mA do 1 A","range":"od 0 W do 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V do 230 V; 1 A do 1,3 A","range":"od 0 W do 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V do 230 V; 1,3 A do 2 A","range":"od 0 W do 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V do 230 V; 2 A do 2,6 A","range":"od 0 W do 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V do 230 V; 2,6 A do 4 A","range":"od 0 W do 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V do 230 V; 4 A do 5,2 A","range":"od 0 W do 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V do 230 V; 5,2 A do 8 A","range":"od 0 W do 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V do 230 V; 8 A do 10 A","range":"od 0 W do 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V do 230 V; 10 A do 15 A","range":"od 0 W do 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V do 230 V; 15 A do 20,5 A","range":"od 0 W do 4,715 kW","cmc":"0,95 mW/VA"},{"name":"230 V do 270 V; 150 mA do 200 mA","range":"od 0 W do 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V do 270 V; 200 mA do 300 mA","range":"od 0 W do 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V do 270 V; 300 mA do 400 mA","range":"od 0 W do 5,535 kW","cmc":"0,81 mW/VA"},{"name":"230 V do 270 V; 400 mA do 600 mA","range":"od 0 W do 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V do 270 V; 600 mA do 800 mA","range":"od 0 W do 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V do 270 V; 800 mA do 1 A","range":"od 0 W do 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V do 270 V; 1 A do 1,3 A","range":"od 0 W do 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V do 270 V; 1,3 A do 2 A","range":"od 0 W do 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V do 270 V; 2 A do 2,6 A","range":"od 0 W do 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V do 270 V; 2,6 A do 4 A","range":"od 0 W do 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V do 270 V; 4 A do 5,2 A","range":"od 0 W do 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V do 270 V; 5,2 A do 8 A","range":"od 0 W do 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V do 270 V; 8 A do 10 A","range":"od 0 W do 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V do 270 V; 10 A do 15 A","range":"od 0 W do 5,535 kW","cmc":"0,78 mW/VA"},{"name":"230 V do 270 V; 15 A do 20,5 A","range":"od 0 W do 5,535 kW","cmc":"0,59 mW/VA"},{"name":"270 V do 540 V; 150 mA do 200 mA","range":"od 0 W do 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V do 540 V; 200 mA do 250 mA","range":"od 0 W do 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V do 540 V; 250 mA do 300 mA","range":"od 0 W do 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V do 540 V; 300 mA do 400 mA","range":"od 0 W do 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V do 540 V; 400 mA do 500 mA","range":"od 0 W do 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V do 540 V; 500 mA do 600 mA","range":"od 0 W do 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V do 540 V; 600 mA do 800 mA","range":"od 0 W do 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V do 540 V; 800 mA do 1 A","range":"od 0 W do 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V do 540 V; 1 A do 1,3 A","range":"od 0 W do 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V do 540 V; 1,3 A do 2 A","range":"od 0 W do 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V do 540 V; 2 A do 2,6 A","range":"od 0 W do 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V do 540 V; 2,6 A do 4 A","range":"od 0 W do 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V do 540 V; 4 A do 5,2 A","range":"od 0 W do 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V do 540 V; 5,2 A do 8 A","range":"od 0 W do 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V do 540 V; 8 A do 10 A","range":"od 0 W do 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V do 540 V; 10 A do 15 A","range":"od 0 W do 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V do 540 V; 15 A do 20,5 A","range":"od 0 W do 11,07 kW","cmc":"0,95 mW/VA"},{"name":"540 V do 560 V; 150 mA do 200 mA","range":"od 0 W do 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V do 560 V; 200 mA do 300 mA","range":"od 0 W do 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V do 560 V; 300 mA do 400 mA","range":"od 0 W do 11,48 kW","cmc":"0,81 mW/VA"},{"name":"540 V do 560 V; 400 mA do 600 mA","range":"od 0 W do 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V do 560 V; 600 mA do 800 mA","range":"od 0 W do 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V do 560 V; 800 mA do 1 A","range":"od 0 W do 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V do 560 V; 1 A do 1,3 A","range":"od 0 W do 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V do 560 V; 1,3 A do 2 A","range":"od 0 W do 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V do 560 V; 2 A do 2,6 A","range":"od 0 W do 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V do 560 V; 2,6 A do 4 A","range":"od 0 W do 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V do 560 V; 4 A do 5,2 A","range":"od 0 W do 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V do 560 V; 5,2 A do 8 A","range":"od 0 W do 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V do 560 V; 8 A do 10 A","range":"od 0 W do 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V do 560 V; 10 A do 15 A","range":"od 0 W do 11,48 kW","cmc":"0,78 mW/VA"},{"name":"540 V do 560 V; 15 A do 20,5 A","range":"od 0 W do 11,48 kW","cmc":"0,59 mW/VA"},{"name":"560 V do 700 V; 150 mA do 200 mA","range":"od 0 W do 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V do 700 V; 200 mA do 250 mA","range":"od 0 W do 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V do 700 V; 250 mA do 300 mA","range":"od 0 W do 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V do 700 V; 300 mA do 400 mA","range":"od 0 W do 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V do 700 V; 400 mA do 500 mA","range":"od 0 W do 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V do 700 V; 500 mA do 600 mA","range":"od 0 W do 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V do 700 V; 600 mA do 800 mA","range":"od 0 W do 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V do 700 V; 800 mA do 1 A","range":"od 0 W do 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V do 700 V; 1 A do 1,3 A","range":"od 0 W do 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V do 700 V; 1,3 A do 2 A","range":"od 0 W do 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V do 700 V; 2 A do 2,6 A","range":"od 0 W do 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V do 700 V; 2,6 A do 4 A","range":"od 0 W do 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V do 700 V; 4 A do 5,2 A","range":"od 0 W do 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V do 700 V; 5,2 A do 8 A","range":"od 0 W do 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V do 700 V; 8 A do 10 A","range":"od 0 W do 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V do 700 V; 10 A do 15 A","range":"od 0 W do 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V do 700 V; 15 A do 20,5 A","range":"od 0 W do 14,35 kW","cmc":"0,95 mW/VA"},{"name":"700 V do 720 V; 150 mA do 200 mA","range":"od 0 W do 14,76 kW","cmc":"1,1 mW/VA"},{"name":"700 V do 720 V; 200 mA do 250 mA","range":"od 0 W do 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V do 720 V; 250 mA do 300 mA","range":"od 0 W do 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V do 720 V; 300 mA do 400 mA","range":"od 0 W do 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V do 720 V; 400 mA do 500 mA","range":"od 0 W do 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V do 720 V; 500 mA do 600 mA","range":"od 0 W do 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V do 720 V; 600 mA do 800 mA","range":"od 0 W do 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V do 720 V; 800 mA do 1 A","range":"od 0 W do 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V do 720 V; 1 A do 1,3 A","range":"od 0 W do 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V do 720 V; 1,3 A do 2 A","range":"od 0 W do 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V do 720 V; 2 A do 2,6 A","range":"od 0 W do 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V do 720 V; 2,6 A do 4 A","range":"od 0 W do 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V do 720 V; 4 A do 5,2 A","range":"od 0 W do 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V do 720 V; 5,2 A do 8 A","range":"od 0 W do 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V do 720 V; 8 A do 10 A","range":"od 0 W do 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V do 720 V; 10 A do 15 A","range":"od 0 W do 14,76 kW","cmc":"0,97 mW/VA"},{"name":"700 V do 720 V; 15 A do 20,5 A","range":"od 0 W do 14,76 kW","cmc":"0,71 mW/VA"}],"parameters_en":[{"name":"25 V to 30 V; 150 mA to 200 mA","range":"0 W to 615 W","cmc":"0,90 mW/VA"},{"name":"25 V to 30 V; 200 mA to 300 mA","range":"0 W to 615 W","cmc":"0,72 mW/VA"},{"name":"25 V to 30 V; 300 mA to 400 mA","range":"0 W to 615 W","cmc":"0,90 mW/VA"},{"name":"25 V to 30 V; 400 mA to 600 mA","range":"0 W to 615 W","cmc":"0,72 mW/VA"},{"name":"25 V to 30 V; 600 mA to 800 mA","range":"0 W to 615 W","cmc":"0,90 mW/VA"},{"name":"25 V to 30 V; 800 mA to 1,3 A","range":"0 W to 615 W","cmc":"0,72 mW/VA"},{"name":"25 V to 30 V; 1,3 A to 2 A","range":"0 W to 615 W","cmc":"0,85 mW/VA"},{"name":"25 V to 30 V; 2 A to 2,6 A","range":"0 W to 615 W","cmc":"0,62 mW/VA"},{"name":"25 V to 30 V; 2,6 A to 4 A","range":"0 W to 615 W","cmc":"0,85 mW/VA"},{"name":"25 V to 30 V; 4 A to 5,2 A","range":"0 W to 615 W","cmc":"0,62 mW/VA"},{"name":"25 V to 30 V; 5,2 A to 8 A","range":"0 W to 615 W","cmc":"0,85 mW/VA"},{"name":"25 V to 30 V; 8 A to 10 A","range":"0 W to 615 W","cmc":"0,62 mW/VA"},{"name":"25 V to 30 V; 10 A to 15 A","range":"0 W to 615 W","cmc":"0,87 mW/VA"},{"name":"25 V to 30 V; 15 A to 20,5 A","range":"0 W to 615 W","cmc":"0,65 mW/VA"},{"name":"30 V to 50 V; 150 mA to 200 mA","range":"0 W to 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V to 50 V; 200 mA to 250 mA","range":"0 W to 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V to 50 V; 250 mA to 300 mA","range":"0 W to 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V to 50 V; 300 mA to 400 mA","range":"0 W to 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V to 50 V; 400 mA to 500 mA","range":"0 W to 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V to 50 V; 500 mA to 600 mA","range":"0 W to 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V to 50 V; 600 mA to 800 mA","range":"0 W to 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V to 50 V; 800 mA to 1 A","range":"0 W to 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V to 50 V; 1 A to 1,3 A","range":"0 W to 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V to 50 V; 1,3 A to 2 A","range":"0 W to 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V to 50 V; 2 A to 2,6 A","range":"0 W to 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V to 50 V; 2,6 A to 4 A","range":"0 W to 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V to 50 V; 4 A to 5,2 A","range":"0 W to 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V to 50 V; 5,2 A to 8 A","range":"0 W to 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V to 50 V; 8 A to 10 A","range":"0 W to 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V to 50 V; 10 A to 15 A","range":"0 W to 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V to 50 V; 15 A to 20,5 A","range":"0 W to 1,025 kW","cmc":"0,95 mW/VA"},{"name":"50 V to 60 V; 150 mA to 200 mA","range":"0 W to 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V to 60 V; 200 mA to 300 mA","range":"0 W to 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V to 60 V; 300 mA to 400 mA","range":"0 W to 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V to 60 V; 400 mA to 600 mA","range":"0 W to 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V to 60 V; 600 mA to 800 mA","range":"0 W to 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V to 60 V; 800 mA to 1,3 A","range":"0 W to 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V to 60 V; 1,3 A to 2 A","range":"0 W to 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V to 60 V; 2 A to 2,6 A","range":"0 W to 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V to 60 V; 2,6 A to 4 A","range":"0 W to 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V to 60 V; 4 A to 5,2 A","range":"0 W to 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V to 60 V; 5,2 A to 8 A","range":"0 W to 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V to 60 V; 8 A to 10 A","range":"0 W to 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V to 60 V; 10 A to 15 A","range":"0 W to 1,23 kW","cmc":"0,87 mW/VA"},{"name":"50 V to 60 V; 15 A to 20,5 A","range":"0 W to 1,23 kW","cmc":"0,65 mW/VA"},{"name":"60 V to 120 V; 150 mA to 200 mA","range":"0 W to 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V to 120 V; 200 mA to 250 mA","range":"0 W to 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V to 120 V; 250 mA to 300 mA","range":"0 W to 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V to 120 V; 300 mA to 400 mA","range":"0 W to 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V to 120 V; 400 mA to 500 mA","range":"0 W to 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V to 120 V; 500 mA to 600 mA","range":"0 W to 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V to 120 V; 600 mA to 800 mA","range":"0 W to 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V to 120 V; 800 mA to 1 A","range":"0 W to 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V to 120 V; 1 A to 1,3 A","range":"0 W to 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V to 120 V; 1,3 A to 2 A","range":"0 W to 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V to 120 V; 2 A to 2,6 A","range":"0 W to 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V to 120 V; 2,6 A to 4 A","range":"0 W to 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V to 120 V; 4 A to 5,2 A","range":"0 W to 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V to 120 V; 5,2 A to 8 A","range":"0 W to 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V to 120 V; 8 A to 10 A","range":"0 W to 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V to 120 V; 10 A to 15 A","range":"0 W to 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V to 120 V; 15 A to 20,5 A","range":"0 W to 2,46 kW","cmc":"0,95 mW/VA"},{"name":"120 V to 130 V; 150 mA to 200 mA","range":"0 W to 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V to 130 V; 200 mA to 300 mA","range":"0 W to 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V to 130 V; 300 mA to 400 mA","range":"0 W to 2,665 kW","cmc":"0,81 mW/VA"},{"name":"120 V to 130 V; 400 mA to 600 mA","range":"0 W to 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V to 130 V; 600 mA to 800 mA","range":"0 W to 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V to 130 V; 800 mA to 1 A","range":"0 W to 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V to 130 V; 1 A to 1,3 A","range":"0 W to 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V to 130 V; 1,3 A to 2 A","range":"0 W to 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V to 130 V; 2 A to 2,6 A","range":"0 W to 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V to 130 V; 2,6 A to 4 A","range":"0 W to 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V to 130 V; 4 A to 5,2 A","range":"0 W to 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V to 130 V; 5,2 A to 8 A","range":"0 W to 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V to 130 V; 8 A to 10 A","range":"0 W to 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V to 130 V; 10 A to 15 A","range":"0 W to 2,665 kW","cmc":"0,78 mW/VA"},{"name":"120 V to 130 V; 15 A to 20,5 A","range":"0 W to 2,665 kW","cmc":"0,59 mW/VA"},{"name":"130 V to 230 V; 150 mA to 200 mA","range":"0 W to 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V to 230 V; 200 mA to 250 mA","range":"0 W to 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V to 230 V; 250 mA to 300 mA","range":"0 W to 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V to 230 V; 300 mA to 400 mA","range":"0 W to 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V to 230 V; 400 mA to 500 mA","range":"0 W to 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V to 230 V; 500 mA to 600 mA","range":"0 W to 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V to 230 V; 600 mA to 800 mA","range":"0 W to 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V to 230 V; 800 mA to 1 A","range":"0 W to 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V to 230 V; 1 A to 1,3 A","range":"0 W to 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V to 230 V; 1,3 A to 2 A","range":"0 W to 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V to 230 V; 2 A to 2,6 A","range":"0 W to 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V to 230 V; 2,6 A to 4 A","range":"0 W to 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V to 230 V; 4 A to 5,2 A","range":"0 W to 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V to 230 V; 5,2 A to 8 A","range":"0 W to 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V to 230 V; 8 A to 10 A","range":"0 W to 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V to 230 V; 10 A to 15 A","range":"0 W to 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V to 230 V; 15 A to 20,5 A","range":"0 W to 4,715 kW","cmc":"0,95 mW/VA"},{"name":"230 V to 270 V; 150 mA to 200 mA","range":"0 W to 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V to 270 V; 200 mA to 300 mA","range":"0 W to 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V to 270 V; 300 mA to 400 mA","range":"0 W to 5,535 kW","cmc":"0,81 mW/VA"},{"name":"230 V to 270 V; 400 mA to 600 mA","range":"0 W to 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V to 270 V; 600 mA to 800 mA","range":"0 W to 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V to 270 V; 800 mA to 1 A","range":"0 W to 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V to 270 V; 1 A to 1,3 A","range":"0 W to 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V to 270 V; 1,3 A to 2 A","range":"0 W to 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V to 270 V; 2 A to 2,6 A","range":"0 W to 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V to 270 V; 2,6 A to 4 A","range":"0 W to 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V to 270 V; 4 A to 5,2 A","range":"0 W to 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V to 270 V; 5,2 A to 8 A","range":"0 W to 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V to 270 V; 8 A to 10 A","range":"0 W to 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V to 270 V; 10 A to 15 A","range":"0 W to 5,535 kW","cmc":"0,78 mW/VA"},{"name":"230 V to 270 V; 15 A to 20,5 A","range":"0 W to 5,535 kW","cmc":"0,59 mW/VA"},{"name":"270 V to 540 V; 150 mA to 200 mA","range":"0 W to 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V to 540 V; 200 mA to 250 mA","range":"0 W to 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V to 540 V; 250 mA to 300 mA","range":"0 W to 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V to 540 V; 300 mA to 400 mA","range":"0 W to 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V to 540 V; 400 mA to 500 mA","range":"0 W to 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V to 540 V; 500 mA to 600 mA","range":"0 W to 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V to 540 V; 600 mA to 800 mA","range":"0 W to 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V to 540 V; 800 mA to 1 A","range":"0 W to 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V to 540 V; 1 A to 1,3 A","range":"0 W to 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V to 540 V; 1,3 A to 2 A","range":"0 W to 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V to 540 V; 2 A to 2,6 A","range":"0 W to 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V to 540 V; 2,6 A to 4 A","range":"0 W to 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V to 540 V; 4 A to 5,2 A","range":"0 W to 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V to 540 V; 5,2 A to 8 A","range":"0 W to 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V to 540 V; 8 A to 10 A","range":"0 W to 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V to 540 V; 10 A to 15 A","range":"0 W to 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V to 540 V; 15 A to 20,5 A","range":"0 W to 11,07 kW","cmc":"0,95 mW/VA"},{"name":"540 V to 560 V; 150 mA to 200 mA","range":"0 W to 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V to 560 V; 200 mA to 300 mA","range":"0 W to 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V to 560 V; 300 mA to 400 mA","range":"0 W to 11,48 kW","cmc":"0,81 mW/VA"},{"name":"540 V to 560 V; 400 mA to 600 mA","range":"0 W to 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V to 560 V; 600 mA to 800 mA","range":"0 W to 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V to 560 V; 800 mA to 1 A","range":"0 W to 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V to 560 V; 1 A to 1,3 A","range":"0 W to 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V to 560 V; 1,3 A to 2 A","range":"0 W to 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V to 560 V; 2 A to 2,6 A","range":"0 W to 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V to 560 V; 2,6 A to 4 A","range":"0 W to 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V to 560 V; 4 A to 5,2 A","range":"0 W to 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V to 560 V; 5,2 A to 8 A","range":"0 W to 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V to 560 V; 8 A to 10 A","range":"0 W to 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V to 560 V; 10 A to 15 A","range":"0 W to 11,48 kW","cmc":"0,78 mW/VA"},{"name":"540 V to 560 V; 15 A to 20,5 A","range":"0 W to 11,48 kW","cmc":"0,59 mW/VA"},{"name":"560 V to 700 V; 150 mA to 200 mA","range":"0 W to 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V to 700 V; 200 mA to 250 mA","range":"0 W to 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V to 700 V; 250 mA to 300 mA","range":"0 W to 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V to 700 V; 300 mA to 400 mA","range":"0 W to 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V to 700 V; 400 mA to 500 mA","range":"0 W to 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V to 700 V; 500 mA to 600 mA","range":"0 W to 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V to 700 V; 600 mA to 800 mA","range":"0 W to 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V to 700 V; 800 mA to 1 A","range":"0 W to 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V to 700 V; 1 A to 1,3 A","range":"0 W to 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V to 700 V; 1,3 A to 2 A","range":"0 W to 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V to 700 V; 2 A to 2,6 A","range":"0 W to 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V to 700 V; 2,6 A to 4 A","range":"0 W to 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V to 700 V; 4 A to 5,2 A","range":"0 W to 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V to 700 V; 5,2 A to 8 A","range":"0 W to 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V to 700 V; 8 A to 10 A","range":"0 W to 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V to 700 V; 10 A to 15 A","range":"0 W to 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V to 700 V; 15 A to 20,5 A","range":"0 W to 14,35 kW","cmc":"0,95 mW/VA"},{"name":"700 V to 720 V; 150 mA to 200 mA","range":"0 W to 14,76 kW","cmc":"1,1 mW/VA"},{"name":"700 V to 720 V; 200 mA to 250 mA","range":"0 W to 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V to 720 V; 250 mA to 300 mA","range":"0 W to 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V to 720 V; 300 mA to 400 mA","range":"0 W to 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V to 720 V; 400 mA to 500 mA","range":"0 W to 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V to 720 V; 500 mA to 600 mA","range":"0 W to 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V to 720 V; 600 mA to 800 mA","range":"0 W to 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V to 720 V; 800 mA to 1 A","range":"0 W to 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V to 720 V; 1 A to 1,3 A","range":"0 W to 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V to 720 V; 1,3 A to 2 A","range":"0 W to 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V to 720 V; 2 A to 2,6 A","range":"0 W to 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V to 720 V; 2,6 A to 4 A","range":"0 W to 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V to 720 V; 4 A to 5,2 A","range":"0 W to 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V to 720 V; 5,2 A to 8 A","range":"0 W to 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V to 720 V; 8 A to 10 A","range":"0 W to 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V to 720 V; 10 A to 15 A","range":"0 W to 14,76 kW","cmc":"0,97 mW/VA"},{"name":"700 V to 720 V; 15 A to 20,5 A","range":"0 W to 14,76 kW","cmc":"0,71 mW/VA"}],"parameters_zh":[{"name":"25 V 至 30 V；150 mA 至 200 mA","range":"0 W 至 615 W","cmc":"0,90 mW/VA"},{"name":"25 V 至 30 V；200 mA 至 300 mA","range":"0 W 至 615 W","cmc":"0,72 mW/VA"},{"name":"25 V 至 30 V；300 mA 至 400 mA","range":"0 W 至 615 W","cmc":"0,90 mW/VA"},{"name":"25 V 至 30 V；400 mA 至 600 mA","range":"0 W 至 615 W","cmc":"0,72 mW/VA"},{"name":"25 V 至 30 V；600 mA 至 800 mA","range":"0 W 至 615 W","cmc":"0,90 mW/VA"},{"name":"25 V 至 30 V；800 mA 至 1,3 A","range":"0 W 至 615 W","cmc":"0,72 mW/VA"},{"name":"25 V 至 30 V；1,3 A 至 2 A","range":"0 W 至 615 W","cmc":"0,85 mW/VA"},{"name":"25 V 至 30 V；2 A 至 2,6 A","range":"0 W 至 615 W","cmc":"0,62 mW/VA"},{"name":"25 V 至 30 V；2,6 A 至 4 A","range":"0 W 至 615 W","cmc":"0,85 mW/VA"},{"name":"25 V 至 30 V；4 A 至 5,2 A","range":"0 W 至 615 W","cmc":"0,62 mW/VA"},{"name":"25 V 至 30 V；5,2 A 至 8 A","range":"0 W 至 615 W","cmc":"0,85 mW/VA"},{"name":"25 V 至 30 V；8 A 至 10 A","range":"0 W 至 615 W","cmc":"0,62 mW/VA"},{"name":"25 V 至 30 V；10 A 至 15 A","range":"0 W 至 615 W","cmc":"0,87 mW/VA"},{"name":"25 V 至 30 V；15 A 至 20,5 A","range":"0 W 至 615 W","cmc":"0,65 mW/VA"},{"name":"30 V 至 50 V；150 mA 至 200 mA","range":"0 W 至 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V 至 50 V；200 mA 至 250 mA","range":"0 W 至 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V 至 50 V；250 mA 至 300 mA","range":"0 W 至 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V 至 50 V；300 mA 至 400 mA","range":"0 W 至 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V 至 50 V；400 mA 至 500 mA","range":"0 W 至 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V 至 50 V；500 mA 至 600 mA","range":"0 W 至 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V 至 50 V；600 mA 至 800 mA","range":"0 W 至 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V 至 50 V；800 mA 至 1 A","range":"0 W 至 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V 至 50 V；1 A 至 1,3 A","range":"0 W 至 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V 至 50 V；1,3 A 至 2 A","range":"0 W 至 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V 至 50 V；2 A 至 2,6 A","range":"0 W 至 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V 至 50 V；2,6 A 至 4 A","range":"0 W 至 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V 至 50 V；4 A 至 5,2 A","range":"0 W 至 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V 至 50 V；5,2 A 至 8 A","range":"0 W 至 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V 至 50 V；8 A 至 10 A","range":"0 W 至 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V 至 50 V；10 A 至 15 A","range":"0 W 至 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V 至 50 V；15 A 至 20,5 A","range":"0 W 至 1,025 kW","cmc":"0,95 mW/VA"},{"name":"50 V 至 60 V；150 mA 至 200 mA","range":"0 W 至 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V 至 60 V；200 mA 至 300 mA","range":"0 W 至 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V 至 60 V；300 mA 至 400 mA","range":"0 W 至 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V 至 60 V；400 mA 至 600 mA","range":"0 W 至 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V 至 60 V；600 mA 至 800 mA","range":"0 W 至 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V 至 60 V；800 mA 至 1,3 A","range":"0 W 至 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V 至 60 V；1,3 A 至 2 A","range":"0 W 至 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V 至 60 V；2 A 至 2,6 A","range":"0 W 至 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V 至 60 V；2,6 A 至 4 A","range":"0 W 至 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V 至 60 V；4 A 至 5,2 A","range":"0 W 至 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V 至 60 V；5,2 A 至 8 A","range":"0 W 至 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V 至 60 V；8 A 至 10 A","range":"0 W 至 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V 至 60 V；10 A 至 15 A","range":"0 W 至 1,23 kW","cmc":"0,87 mW/VA"},{"name":"50 V 至 60 V；15 A 至 20,5 A","range":"0 W 至 1,23 kW","cmc":"0,65 mW/VA"},{"name":"60 V 至 120 V；150 mA 至 200 mA","range":"0 W 至 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V 至 120 V；200 mA 至 250 mA","range":"0 W 至 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V 至 120 V；250 mA 至 300 mA","range":"0 W 至 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V 至 120 V；300 mA 至 400 mA","range":"0 W 至 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V 至 120 V；400 mA 至 500 mA","range":"0 W 至 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V 至 120 V；500 mA 至 600 mA","range":"0 W 至 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V 至 120 V；600 mA 至 800 mA","range":"0 W 至 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V 至 120 V；800 mA 至 1 A","range":"0 W 至 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V 至 120 V；1 A 至 1,3 A","range":"0 W 至 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V 至 120 V；1,3 A 至 2 A","range":"0 W 至 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V 至 120 V；2 A 至 2,6 A","range":"0 W 至 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V 至 120 V；2,6 A 至 4 A","range":"0 W 至 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V 至 120 V；4 A 至 5,2 A","range":"0 W 至 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V 至 120 V；5,2 A 至 8 A","range":"0 W 至 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V 至 120 V；8 A 至 10 A","range":"0 W 至 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V 至 120 V；10 A 至 15 A","range":"0 W 至 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V 至 120 V；15 A 至 20,5 A","range":"0 W 至 2,46 kW","cmc":"0,95 mW/VA"},{"name":"120 V 至 130 V；150 mA 至 200 mA","range":"0 W 至 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V 至 130 V；200 mA 至 300 mA","range":"0 W 至 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V 至 130 V；300 mA 至 400 mA","range":"0 W 至 2,665 kW","cmc":"0,81 mW/VA"},{"name":"120 V 至 130 V；400 mA 至 600 mA","range":"0 W 至 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V 至 130 V；600 mA 至 800 mA","range":"0 W 至 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V 至 130 V；800 mA 至 1 A","range":"0 W 至 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V 至 130 V；1 A 至 1,3 A","range":"0 W 至 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V 至 130 V；1,3 A 至 2 A","range":"0 W 至 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V 至 130 V；2 A 至 2,6 A","range":"0 W 至 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V 至 130 V；2,6 A 至 4 A","range":"0 W 至 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V 至 130 V；4 A 至 5,2 A","range":"0 W 至 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V 至 130 V；5,2 A 至 8 A","range":"0 W 至 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V 至 130 V；8 A 至 10 A","range":"0 W 至 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V 至 130 V；10 A 至 15 A","range":"0 W 至 2,665 kW","cmc":"0,78 mW/VA"},{"name":"120 V 至 130 V；15 A 至 20,5 A","range":"0 W 至 2,665 kW","cmc":"0,59 mW/VA"},{"name":"130 V 至 230 V；150 mA 至 200 mA","range":"0 W 至 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V 至 230 V；200 mA 至 250 mA","range":"0 W 至 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V 至 230 V；250 mA 至 300 mA","range":"0 W 至 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V 至 230 V；300 mA 至 400 mA","range":"0 W 至 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V 至 230 V；400 mA 至 500 mA","range":"0 W 至 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V 至 230 V；500 mA 至 600 mA","range":"0 W 至 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V 至 230 V；600 mA 至 800 mA","range":"0 W 至 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V 至 230 V；800 mA 至 1 A","range":"0 W 至 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V 至 230 V；1 A 至 1,3 A","range":"0 W 至 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V 至 230 V；1,3 A 至 2 A","range":"0 W 至 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V 至 230 V；2 A 至 2,6 A","range":"0 W 至 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V 至 230 V；2,6 A 至 4 A","range":"0 W 至 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V 至 230 V；4 A 至 5,2 A","range":"0 W 至 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V 至 230 V；5,2 A 至 8 A","range":"0 W 至 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V 至 230 V；8 A 至 10 A","range":"0 W 至 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V 至 230 V；10 A 至 15 A","range":"0 W 至 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V 至 230 V；15 A 至 20,5 A","range":"0 W 至 4,715 kW","cmc":"0,95 mW/VA"},{"name":"230 V 至 270 V；150 mA 至 200 mA","range":"0 W 至 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V 至 270 V；200 mA 至 300 mA","range":"0 W 至 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V 至 270 V；300 mA 至 400 mA","range":"0 W 至 5,535 kW","cmc":"0,81 mW/VA"},{"name":"230 V 至 270 V；400 mA 至 600 mA","range":"0 W 至 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V 至 270 V；600 mA 至 800 mA","range":"0 W 至 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V 至 270 V；800 mA 至 1 A","range":"0 W 至 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V 至 270 V；1 A 至 1,3 A","range":"0 W 至 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V 至 270 V；1,3 A 至 2 A","range":"0 W 至 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V 至 270 V；2 A 至 2,6 A","range":"0 W 至 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V 至 270 V；2,6 A 至 4 A","range":"0 W 至 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V 至 270 V；4 A 至 5,2 A","range":"0 W 至 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V 至 270 V；5,2 A 至 8 A","range":"0 W 至 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V 至 270 V；8 A 至 10 A","range":"0 W 至 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V 至 270 V；10 A 至 15 A","range":"0 W 至 5,535 kW","cmc":"0,78 mW/VA"},{"name":"230 V 至 270 V；15 A 至 20,5 A","range":"0 W 至 5,535 kW","cmc":"0,59 mW/VA"},{"name":"270 V 至 540 V；150 mA 至 200 mA","range":"0 W 至 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V 至 540 V；200 mA 至 250 mA","range":"0 W 至 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V 至 540 V；250 mA 至 300 mA","range":"0 W 至 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V 至 540 V；300 mA 至 400 mA","range":"0 W 至 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V 至 540 V；400 mA 至 500 mA","range":"0 W 至 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V 至 540 V；500 mA 至 600 mA","range":"0 W 至 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V 至 540 V；600 mA 至 800 mA","range":"0 W 至 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V 至 540 V；800 mA 至 1 A","range":"0 W 至 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V 至 540 V；1 A 至 1,3 A","range":"0 W 至 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V 至 540 V；1,3 A 至 2 A","range":"0 W 至 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V 至 540 V；2 A 至 2,6 A","range":"0 W 至 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V 至 540 V；2,6 A 至 4 A","range":"0 W 至 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V 至 540 V；4 A 至 5,2 A","range":"0 W 至 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V 至 540 V；5,2 A 至 8 A","range":"0 W 至 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V 至 540 V；8 A 至 10 A","range":"0 W 至 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V 至 540 V；10 A 至 15 A","range":"0 W 至 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V 至 540 V；15 A 至 20,5 A","range":"0 W 至 11,07 kW","cmc":"0,95 mW/VA"},{"name":"540 V 至 560 V；150 mA 至 200 mA","range":"0 W 至 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V 至 560 V；200 mA 至 300 mA","range":"0 W 至 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V 至 560 V；300 mA 至 400 mA","range":"0 W 至 11,48 kW","cmc":"0,81 mW/VA"},{"name":"540 V 至 560 V；400 mA 至 600 mA","range":"0 W 至 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V 至 560 V；600 mA 至 800 mA","range":"0 W 至 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V 至 560 V；800 mA 至 1 A","range":"0 W 至 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V 至 560 V；1 A 至 1,3 A","range":"0 W 至 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V 至 560 V；1,3 A 至 2 A","range":"0 W 至 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V 至 560 V；2 A 至 2,6 A","range":"0 W 至 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V 至 560 V；2,6 A 至 4 A","range":"0 W 至 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V 至 560 V；4 A 至 5,2 A","range":"0 W 至 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V 至 560 V；5,2 A 至 8 A","range":"0 W 至 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V 至 560 V；8 A 至 10 A","range":"0 W 至 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V 至 560 V；10 A 至 15 A","range":"0 W 至 11,48 kW","cmc":"0,78 mW/VA"},{"name":"540 V 至 560 V；15 A 至 20,5 A","range":"0 W 至 11,48 kW","cmc":"0,59 mW/VA"},{"name":"560 V 至 700 V；150 mA 至 200 mA","range":"0 W 至 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V 至 700 V；200 mA 至 250 mA","range":"0 W 至 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V 至 700 V；250 mA 至 300 mA","range":"0 W 至 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V 至 700 V；300 mA 至 400 mA","range":"0 W 至 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V 至 700 V；400 mA 至 500 mA","range":"0 W 至 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V 至 700 V；500 mA 至 600 mA","range":"0 W 至 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V 至 700 V；600 mA 至 800 mA","range":"0 W 至 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V 至 700 V；800 mA 至 1 A","range":"0 W 至 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V 至 700 V；1 A 至 1,3 A","range":"0 W 至 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V 至 700 V；1,3 A 至 2 A","range":"0 W 至 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V 至 700 V；2 A 至 2,6 A","range":"0 W 至 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V 至 700 V；2,6 A 至 4 A","range":"0 W 至 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V 至 700 V；4 A 至 5,2 A","range":"0 W 至 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V 至 700 V；5,2 A 至 8 A","range":"0 W 至 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V 至 700 V；8 A 至 10 A","range":"0 W 至 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V 至 700 V；10 A 至 15 A","range":"0 W 至 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V 至 700 V；15 A 至 20,5 A","range":"0 W 至 14,35 kW","cmc":"0,95 mW/VA"},{"name":"700 V 至 720 V；150 mA 至 200 mA","range":"0 W 至 14,76 kW","cmc":"1,1 mW/VA"},{"name":"700 V 至 720 V；200 mA 至 250 mA","range":"0 W 至 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V 至 720 V；250 mA 至 300 mA","range":"0 W 至 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V 至 720 V；300 mA 至 400 mA","range":"0 W 至 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V 至 720 V；400 mA 至 500 mA","range":"0 W 至 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V 至 720 V；500 mA 至 600 mA","range":"0 W 至 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V 至 720 V；600 mA 至 800 mA","range":"0 W 至 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V 至 720 V；800 mA 至 1 A","range":"0 W 至 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V 至 720 V；1 A 至 1,3 A","range":"0 W 至 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V 至 720 V；1,3 A 至 2 A","range":"0 W 至 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V 至 720 V；2 A 至 2,6 A","range":"0 W 至 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V 至 720 V；2,6 A 至 4 A","range":"0 W 至 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V 至 720 V；4 A 至 5,2 A","range":"0 W 至 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V 至 720 V；5,2 A 至 8 A","range":"0 W 至 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V 至 720 V；8 A 至 10 A","range":"0 W 至 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V 至 720 V；10 A 至 15 A","range":"0 W 至 14,76 kW","cmc":"0,97 mW/VA"},{"name":"700 V 至 720 V；15 A 至 20,5 A","range":"0 W 至 14,76 kW","cmc":"0,71 mW/VA"}],"parameters_cs":[{"name":"25 V až 30 V; 150 mA až 200 mA","range":"0 W až 615 W","cmc":"0,90 mW/VA"},{"name":"25 V až 30 V; 200 mA až 300 mA","range":"0 W až 615 W","cmc":"0,72 mW/VA"},{"name":"25 V až 30 V; 300 mA až 400 mA","range":"0 W až 615 W","cmc":"0,90 mW/VA"},{"name":"25 V až 30 V; 400 mA až 600 mA","range":"0 W až 615 W","cmc":"0,72 mW/VA"},{"name":"25 V až 30 V; 600 mA až 800 mA","range":"0 W až 615 W","cmc":"0,90 mW/VA"},{"name":"25 V až 30 V; 800 mA až 1,3 A","range":"0 W až 615 W","cmc":"0,72 mW/VA"},{"name":"25 V až 30 V; 1,3 A až 2 A","range":"0 W až 615 W","cmc":"0,85 mW/VA"},{"name":"25 V až 30 V; 2 A až 2,6 A","range":"0 W až 615 W","cmc":"0,62 mW/VA"},{"name":"25 V až 30 V; 2,6 A až 4 A","range":"0 W až 615 W","cmc":"0,85 mW/VA"},{"name":"25 V až 30 V; 4 A až 5,2 A","range":"0 W až 615 W","cmc":"0,62 mW/VA"},{"name":"25 V až 30 V; 5,2 A až 8 A","range":"0 W až 615 W","cmc":"0,85 mW/VA"},{"name":"25 V až 30 V; 8 A až 10 A","range":"0 W až 615 W","cmc":"0,62 mW/VA"},{"name":"25 V až 30 V; 10 A až 15 A","range":"0 W až 615 W","cmc":"0,87 mW/VA"},{"name":"25 V až 30 V; 15 A až 20,5 A","range":"0 W až 615 W","cmc":"0,65 mW/VA"},{"name":"30 V až 50 V; 150 mA až 200 mA","range":"0 W až 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V až 50 V; 200 mA až 250 mA","range":"0 W až 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V až 50 V; 250 mA až 300 mA","range":"0 W až 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V až 50 V; 300 mA až 400 mA","range":"0 W až 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V až 50 V; 400 mA až 500 mA","range":"0 W až 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V až 50 V; 500 mA až 600 mA","range":"0 W až 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V až 50 V; 600 mA až 800 mA","range":"0 W až 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V až 50 V; 800 mA až 1 A","range":"0 W až 1,025 kW","cmc":"1,1 mW/VA"},{"name":"30 V až 50 V; 1 A až 1,3 A","range":"0 W až 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V až 50 V; 1,3 A až 2 A","range":"0 W až 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V až 50 V; 2 A až 2,6 A","range":"0 W až 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V až 50 V; 2,6 A až 4 A","range":"0 W až 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V až 50 V; 4 A až 5,2 A","range":"0 W až 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V až 50 V; 5,2 A až 8 A","range":"0 W až 1,025 kW","cmc":"1,3 mW/VA"},{"name":"30 V až 50 V; 8 A až 10 A","range":"0 W až 1,025 kW","cmc":"0,90 mW/VA"},{"name":"30 V až 50 V; 10 A až 15 A","range":"0 W až 1,025 kW","cmc":"1,4 mW/VA"},{"name":"30 V až 50 V; 15 A až 20,5 A","range":"0 W až 1,025 kW","cmc":"0,95 mW/VA"},{"name":"50 V až 60 V; 150 mA až 200 mA","range":"0 W až 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V až 60 V; 200 mA až 300 mA","range":"0 W až 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V až 60 V; 300 mA až 400 mA","range":"0 W až 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V až 60 V; 400 mA až 600 mA","range":"0 W až 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V až 60 V; 600 mA až 800 mA","range":"0 W až 1,23 kW","cmc":"0,90 mW/VA"},{"name":"50 V až 60 V; 800 mA až 1,3 A","range":"0 W až 1,23 kW","cmc":"0,72 mW/VA"},{"name":"50 V až 60 V; 1,3 A až 2 A","range":"0 W až 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V až 60 V; 2 A až 2,6 A","range":"0 W až 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V až 60 V; 2,6 A až 4 A","range":"0 W až 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V až 60 V; 4 A až 5,2 A","range":"0 W až 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V až 60 V; 5,2 A až 8 A","range":"0 W až 1,23 kW","cmc":"0,85 mW/VA"},{"name":"50 V až 60 V; 8 A až 10 A","range":"0 W až 1,23 kW","cmc":"0,62 mW/VA"},{"name":"50 V až 60 V; 10 A až 15 A","range":"0 W až 1,23 kW","cmc":"0,87 mW/VA"},{"name":"50 V až 60 V; 15 A až 20,5 A","range":"0 W až 1,23 kW","cmc":"0,65 mW/VA"},{"name":"60 V až 120 V; 150 mA až 200 mA","range":"0 W až 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V až 120 V; 200 mA až 250 mA","range":"0 W až 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V až 120 V; 250 mA až 300 mA","range":"0 W až 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V až 120 V; 300 mA až 400 mA","range":"0 W až 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V až 120 V; 400 mA až 500 mA","range":"0 W až 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V až 120 V; 500 mA až 600 mA","range":"0 W až 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V až 120 V; 600 mA až 800 mA","range":"0 W až 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V až 120 V; 800 mA až 1 A","range":"0 W až 2,46 kW","cmc":"1,1 mW/VA"},{"name":"60 V až 120 V; 1 A až 1,3 A","range":"0 W až 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V až 120 V; 1,3 A až 2 A","range":"0 W až 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V až 120 V; 2 A až 2,6 A","range":"0 W až 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V až 120 V; 2,6 A až 4 A","range":"0 W až 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V až 120 V; 4 A až 5,2 A","range":"0 W až 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V až 120 V; 5,2 A až 8 A","range":"0 W až 2,46 kW","cmc":"1,3 mW/VA"},{"name":"60 V až 120 V; 8 A až 10 A","range":"0 W až 2,46 kW","cmc":"0,90 mW/VA"},{"name":"60 V až 120 V; 10 A až 15 A","range":"0 W až 2,46 kW","cmc":"1,4 mW/VA"},{"name":"60 V až 120 V; 15 A až 20,5 A","range":"0 W až 2,46 kW","cmc":"0,95 mW/VA"},{"name":"120 V až 130 V; 150 mA až 200 mA","range":"0 W až 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V až 130 V; 200 mA až 300 mA","range":"0 W až 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V až 130 V; 300 mA až 400 mA","range":"0 W až 2,665 kW","cmc":"0,81 mW/VA"},{"name":"120 V až 130 V; 400 mA až 600 mA","range":"0 W až 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V až 130 V; 600 mA až 800 mA","range":"0 W až 2,665 kW","cmc":"0,80 mW/VA"},{"name":"120 V až 130 V; 800 mA až 1 A","range":"0 W až 2,665 kW","cmc":"0,65 mW/VA"},{"name":"120 V až 130 V; 1 A až 1,3 A","range":"0 W až 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V až 130 V; 1,3 A až 2 A","range":"0 W až 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V až 130 V; 2 A až 2,6 A","range":"0 W až 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V až 130 V; 2,6 A až 4 A","range":"0 W až 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V až 130 V; 4 A až 5,2 A","range":"0 W až 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V až 130 V; 5,2 A až 8 A","range":"0 W až 2,665 kW","cmc":"0,76 mW/VA"},{"name":"120 V až 130 V; 8 A až 10 A","range":"0 W až 2,665 kW","cmc":"0,56 mW/VA"},{"name":"120 V až 130 V; 10 A až 15 A","range":"0 W až 2,665 kW","cmc":"0,78 mW/VA"},{"name":"120 V až 130 V; 15 A až 20,5 A","range":"0 W až 2,665 kW","cmc":"0,59 mW/VA"},{"name":"130 V až 230 V; 150 mA až 200 mA","range":"0 W až 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V až 230 V; 200 mA až 250 mA","range":"0 W až 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V až 230 V; 250 mA až 300 mA","range":"0 W až 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V až 230 V; 300 mA až 400 mA","range":"0 W až 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V až 230 V; 400 mA až 500 mA","range":"0 W až 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V až 230 V; 500 mA až 600 mA","range":"0 W až 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V až 230 V; 600 mA až 800 mA","range":"0 W až 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V až 230 V; 800 mA až 1 A","range":"0 W až 4,715 kW","cmc":"1,1 mW/VA"},{"name":"130 V až 230 V; 1 A až 1,3 A","range":"0 W až 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V až 230 V; 1,3 A až 2 A","range":"0 W až 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V až 230 V; 2 A až 2,6 A","range":"0 W až 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V až 230 V; 2,6 A až 4 A","range":"0 W až 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V až 230 V; 4 A až 5,2 A","range":"0 W až 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V až 230 V; 5,2 A až 8 A","range":"0 W až 4,715 kW","cmc":"1,3 mW/VA"},{"name":"130 V až 230 V; 8 A až 10 A","range":"0 W až 4,715 kW","cmc":"0,90 mW/VA"},{"name":"130 V až 230 V; 10 A až 15 A","range":"0 W až 4,715 kW","cmc":"1,4 mW/VA"},{"name":"130 V až 230 V; 15 A až 20,5 A","range":"0 W až 4,715 kW","cmc":"0,95 mW/VA"},{"name":"230 V až 270 V; 150 mA až 200 mA","range":"0 W až 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V až 270 V; 200 mA až 300 mA","range":"0 W až 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V až 270 V; 300 mA až 400 mA","range":"0 W až 5,535 kW","cmc":"0,81 mW/VA"},{"name":"230 V až 270 V; 400 mA až 600 mA","range":"0 W až 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V až 270 V; 600 mA až 800 mA","range":"0 W až 5,535 kW","cmc":"0,80 mW/VA"},{"name":"230 V až 270 V; 800 mA až 1 A","range":"0 W až 5,535 kW","cmc":"0,65 mW/VA"},{"name":"230 V až 270 V; 1 A až 1,3 A","range":"0 W až 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V až 270 V; 1,3 A až 2 A","range":"0 W až 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V až 270 V; 2 A až 2,6 A","range":"0 W až 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V až 270 V; 2,6 A až 4 A","range":"0 W až 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V až 270 V; 4 A až 5,2 A","range":"0 W až 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V až 270 V; 5,2 A až 8 A","range":"0 W až 5,535 kW","cmc":"0,76 mW/VA"},{"name":"230 V až 270 V; 8 A až 10 A","range":"0 W až 5,535 kW","cmc":"0,56 mW/VA"},{"name":"230 V až 270 V; 10 A až 15 A","range":"0 W až 5,535 kW","cmc":"0,78 mW/VA"},{"name":"230 V až 270 V; 15 A až 20,5 A","range":"0 W až 5,535 kW","cmc":"0,59 mW/VA"},{"name":"270 V až 540 V; 150 mA až 200 mA","range":"0 W až 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V až 540 V; 200 mA až 250 mA","range":"0 W až 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V až 540 V; 250 mA až 300 mA","range":"0 W až 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V až 540 V; 300 mA až 400 mA","range":"0 W až 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V až 540 V; 400 mA až 500 mA","range":"0 W až 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V až 540 V; 500 mA až 600 mA","range":"0 W až 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V až 540 V; 600 mA až 800 mA","range":"0 W až 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V až 540 V; 800 mA až 1 A","range":"0 W až 11,07 kW","cmc":"1,1 mW/VA"},{"name":"270 V až 540 V; 1 A až 1,3 A","range":"0 W až 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V až 540 V; 1,3 A až 2 A","range":"0 W až 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V až 540 V; 2 A až 2,6 A","range":"0 W až 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V až 540 V; 2,6 A až 4 A","range":"0 W až 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V až 540 V; 4 A až 5,2 A","range":"0 W až 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V až 540 V; 5,2 A až 8 A","range":"0 W až 11,07 kW","cmc":"1,3 mW/VA"},{"name":"270 V až 540 V; 8 A až 10 A","range":"0 W až 11,07 kW","cmc":"0,90 mW/VA"},{"name":"270 V až 540 V; 10 A až 15 A","range":"0 W až 11,07 kW","cmc":"1,4 mW/VA"},{"name":"270 V až 540 V; 15 A až 20,5 A","range":"0 W až 11,07 kW","cmc":"0,95 mW/VA"},{"name":"540 V až 560 V; 150 mA až 200 mA","range":"0 W až 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V až 560 V; 200 mA až 300 mA","range":"0 W až 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V až 560 V; 300 mA až 400 mA","range":"0 W až 11,48 kW","cmc":"0,81 mW/VA"},{"name":"540 V až 560 V; 400 mA až 600 mA","range":"0 W až 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V až 560 V; 600 mA až 800 mA","range":"0 W až 11,48 kW","cmc":"0,80 mW/VA"},{"name":"540 V až 560 V; 800 mA až 1 A","range":"0 W až 11,48 kW","cmc":"0,65 mW/VA"},{"name":"540 V až 560 V; 1 A až 1,3 A","range":"0 W až 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V až 560 V; 1,3 A až 2 A","range":"0 W až 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V až 560 V; 2 A až 2,6 A","range":"0 W až 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V až 560 V; 2,6 A až 4 A","range":"0 W až 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V až 560 V; 4 A až 5,2 A","range":"0 W až 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V až 560 V; 5,2 A až 8 A","range":"0 W až 11,48 kW","cmc":"0,76 mW/VA"},{"name":"540 V až 560 V; 8 A až 10 A","range":"0 W až 11,48 kW","cmc":"0,56 mW/VA"},{"name":"540 V až 560 V; 10 A až 15 A","range":"0 W až 11,48 kW","cmc":"0,78 mW/VA"},{"name":"540 V až 560 V; 15 A až 20,5 A","range":"0 W až 11,48 kW","cmc":"0,59 mW/VA"},{"name":"560 V až 700 V; 150 mA až 200 mA","range":"0 W až 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V až 700 V; 200 mA až 250 mA","range":"0 W až 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V až 700 V; 250 mA až 300 mA","range":"0 W až 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V až 700 V; 300 mA až 400 mA","range":"0 W až 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V až 700 V; 400 mA až 500 mA","range":"0 W až 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V až 700 V; 500 mA až 600 mA","range":"0 W až 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V až 700 V; 600 mA až 800 mA","range":"0 W až 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V až 700 V; 800 mA až 1 A","range":"0 W až 14,35 kW","cmc":"1,1 mW/VA"},{"name":"560 V až 700 V; 1 A až 1,3 A","range":"0 W až 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V až 700 V; 1,3 A až 2 A","range":"0 W až 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V až 700 V; 2 A až 2,6 A","range":"0 W až 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V až 700 V; 2,6 A až 4 A","range":"0 W až 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V až 700 V; 4 A až 5,2 A","range":"0 W až 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V až 700 V; 5,2 A až 8 A","range":"0 W až 14,35 kW","cmc":"1,3 mW/VA"},{"name":"560 V až 700 V; 8 A až 10 A","range":"0 W až 14,35 kW","cmc":"0,90 mW/VA"},{"name":"560 V až 700 V; 10 A až 15 A","range":"0 W až 14,35 kW","cmc":"1,4 mW/VA"},{"name":"560 V až 700 V; 15 A až 20,5 A","range":"0 W až 14,35 kW","cmc":"0,95 mW/VA"},{"name":"700 V až 720 V; 150 mA až 200 mA","range":"0 W až 14,76 kW","cmc":"1,1 mW/VA"},{"name":"700 V až 720 V; 200 mA až 250 mA","range":"0 W až 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V až 720 V; 250 mA až 300 mA","range":"0 W až 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V až 720 V; 300 mA až 400 mA","range":"0 W až 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V až 720 V; 400 mA až 500 mA","range":"0 W až 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V až 720 V; 500 mA až 600 mA","range":"0 W až 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V až 720 V; 600 mA až 800 mA","range":"0 W až 14,76 kW","cmc":"1,0 mW/VA"},{"name":"700 V až 720 V; 800 mA až 1 A","range":"0 W až 14,76 kW","cmc":"0,80 mW/VA"},{"name":"700 V až 720 V; 1 A až 1,3 A","range":"0 W až 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V až 720 V; 1,3 A až 2 A","range":"0 W až 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V až 720 V; 2 A až 2,6 A","range":"0 W až 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V až 720 V; 2,6 A až 4 A","range":"0 W až 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V až 720 V; 4 A až 5,2 A","range":"0 W až 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V až 720 V; 5,2 A až 8 A","range":"0 W až 14,76 kW","cmc":"0,94 mW/VA"},{"name":"700 V až 720 V; 8 A až 10 A","range":"0 W až 14,76 kW","cmc":"0,68 mW/VA"},{"name":"700 V až 720 V; 10 A až 15 A","range":"0 W až 14,76 kW","cmc":"0,97 mW/VA"},{"name":"700 V až 720 V; 15 A až 20,5 A","range":"0 W až 14,76 kW","cmc":"0,71 mW/VA"}],"technique":"Pomiar bezpośredni miernikiem mocy","technique_en":"Direct measurement by a power meter","technique_zh":"用功率计直接测量","technique_cs":"Přímé měření měřidlem výkonu","techniques":["Pomiar bezpośredni miernikiem mocy"],"techniques_en":["Direct measurement by a power meter"],"techniques_zh":["用功率计直接测量"],"techniques_cs":["Přímé měření měřidlem výkonu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n25 V do 30 V; 150 mA do 200 mA od 0 W do 615 W CMC 0,90 mW/VA\n25 V do 30 V; 200 mA do 300 mA od 0 W do 615 W CMC 0,72 mW/VA\n25 V do 30 V; 300 mA do 400 mA od 0 W do 615 W CMC 0,90 mW/VA\n25 V do 30 V; 400 mA do 600 mA od 0 W do 615 W CMC 0,72 mW/VA\n25 V do 30 V; 600 mA do 800 mA od 0 W do 615 W CMC 0,90 mW/VA\n25 V do 30 V; 800 mA do 1,3 A od 0 W do 615 W CMC 0,72 mW/VA\n25 V do 30 V; 1,3 A do 2 A od 0 W do 615 W CMC 0,85 mW/VA\n25 V do 30 V; 2 A do 2,6 A od 0 W do 615 W CMC 0,62 mW/VA\n25 V do 30 V; 2,6 A do 4 A od 0 W do 615 W CMC 0,85 mW/VA\n25 V do 30 V; 4 A do 5,2 A od 0 W do 615 W CMC 0,62 mW/VA\n25 V do 30 V; 5,2 A do 8 A od 0 W do 615 W CMC 0,85 mW/VA\n25 V do 30 V; 8 A do 10 A od 0 W do 615 W CMC 0,62 mW/VA\n25 V do 30 V; 10 A do 15 A od 0 W do 615 W CMC 0,87 mW/VA\n25 V do 30 V; 15 A do 20,5 A od 0 W do 615 W CMC 0,65 mW/VA\n30 V do 50 V; 150 mA do 200 mA od 0 W do 1,025 kW CMC 1,4 mW/VA\n30 V do 50 V; 200 mA do 250 mA od 0 W do 1,025 kW CMC 1,1 mW/VA\n30 V do 50 V; 250 mA do 300 mA od 0 W do 1,025 kW CMC 0,90 mW/VA\n30 V do 50 V; 300 mA do 400 mA od 0 W do 1,025 kW CMC 1,4 mW/VA\n30 V do 50 V; 400 mA do 500 mA od 0 W do 1,025 kW CMC 1,1 mW/VA\n30 V do 50 V; 500 mA do 600 mA od 0 W do 1,025 kW CMC 0,90 mW/VA\n30 V do 50 V; 600 mA do 800 mA od 0 W do 1,025 kW CMC 1,4 mW/VA\n30 V do 50 V; 800 mA do 1 A od 0 W do 1,025 kW CMC 1,1 mW/VA\n30 V do 50 V; 1 A do 1,3 A od 0 W do 1,025 kW CMC 0,90 mW/VA\n30 V do 50 V; 1,3 A do 2 A od 0 W do 1,025 kW CMC 1,3 mW/VA\n30 V do 50 V; 2 A do 2,6 A od 0 W do 1,025 kW CMC 0,90 mW/VA\n30 V do 50 V; 2,6 A do 4 A od 0 W do 1,025 kW CMC 1,3 mW/VA\n30 V do 50 V; 4 A do 5,2 A od 0 W do 1,025 kW CMC 0,90 mW/VA\n30 V do 50 V; 5,2 A do 8 A od 0 W do 1,025 kW CMC 1,3 mW/VA\n30 V do 50 V; 8 A do 10 A od 0 W do 1,025 kW CMC 0,90 mW/VA\n30 V do 50 V; 10 A do 15 A od 0 W do 1,025 kW CMC 1,4 mW/VA\n30 V do 50 V; 15 A do 20,5 A od 0 W do 1,025 kW CMC 0,95 mW/VA\n50 V do 60 V; 150 mA do 200 mA od 0 W do 1,23 kW CMC 0,90 mW/VA\n50 V do 60 V; 200 mA do 300 mA od 0 W do 1,23 kW CMC 0,72 mW/VA\n50 V do 60 V; 300 mA do 400 mA od 0 W do 1,23 kW CMC 0,90 mW/VA\n50 V do 60 V; 400 mA do 600 mA od 0 W do 1,23 kW CMC 0,72 mW/VA\n50 V do 60 V; 600 mA do 800 mA od 0 W do 1,23 kW CMC 0,90 mW/VA\n50 V do 60 V; 800 mA do 1,3 A od 0 W do 1,23 kW CMC 0,72 mW/VA\n50 V do 60 V; 1,3 A do 2 A od 0 W do 1,23 kW CMC 0,85 mW/VA\n50 V do 60 V; 2 A do 2,6 A od 0 W do 1,23 kW CMC 0,62 mW/VA\n50 V do 60 V; 2,6 A do 4 A od 0 W do 1,23 kW CMC 0,85 mW/VA\n50 V do 60 V; 4 A do 5,2 A od 0 W do 1,23 kW CMC 0,62 mW/VA\n50 V do 60 V; 5,2 A do 8 A od 0 W do 1,23 kW CMC 0,85 mW/VA\n50 V do 60 V; 8 A do 10 A od 0 W do 1,23 kW CMC 0,62 mW/VA\n50 V do 60 V; 10 A do 15 A od 0 W do 1,23 kW CMC 0,87 mW/VA\n50 V do 60 V; 15 A do 20,5 A od 0 W do 1,23 kW CMC 0,65 mW/VA\n60 V do 120 V; 150 mA do 200 mA od 0 W do 2,46 kW CMC 1,4 mW/VA\n60 V do 120 V; 200 mA do 250 mA od 0 W do 2,46 kW CMC 1,1 mW/VA\n60 V do 120 V; 250 mA do 300 mA od 0 W do 2,46 kW CMC 0,90 mW/VA\n60 V do 120 V; 300 mA do 400 mA od 0 W do 2,46 kW CMC 1,4 mW/VA\n60 V do 120 V; 400 mA do 500 mA od 0 W do 2,46 kW CMC 1,1 mW/VA\n60 V do 120 V; 500 mA do 600 mA od 0 W do 2,46 kW CMC 0,90 mW/VA\n60 V do 120 V; 600 mA do 800 mA od 0 W do 2,46 kW CMC 1,4 mW/VA\n60 V do 120 V; 800 mA do 1 A od 0 W do 2,46 kW CMC 1,1 mW/VA\n60 V do 120 V; 1 A do 1,3 A od 0 W do 2,46 kW CMC 0,90 mW/VA\n60 V do 120 V; 1,3 A do 2 A od 0 W do 2,46 kW CMC 1,3 mW/VA\n60 V do 120 V; 2 A do 2,6 A od 0 W do 2,46 kW CMC 0,90 mW/VA\n60 V do 120 V; 2,6 A do 4 A od 0 W do 2,46 kW CMC 1,3 mW/VA\n60 V do 120 V; 4 A do 5,2 A od 0 W do 2,46 kW CMC 0,90 mW/VA\n60 V do 120 V; 5,2 A do 8 A od 0 W do 2,46 kW CMC 1,3 mW/VA\n60 V do 120 V; 8 A do 10 A od 0 W do 2,46 kW CMC 0,90 mW/VA\n60 V do 120 V; 10 A do 15 A od 0 W do 2,46 kW CMC 1,4 mW/VA\n60 V do 120 V; 15 A do 20,5 A od 0 W do 2,46 kW CMC 0,95 mW/VA\n120 V do 130 V; 150 mA do 200 mA od 0 W do 2,665 kW CMC 0,80 mW/VA\n120 V do 130 V; 200 mA do 300 mA od 0 W do 2,665 kW CMC 0,65 mW/VA\n120 V do 130 V; 300 mA do 400 mA od 0 W do 2,665 kW CMC 0,81 mW/VA\n120 V do 130 V; 400 mA do 600 mA od 0 W do 2,665 kW CMC 0,65 mW/VA\n120 V do 130 V; 600 mA do 800 mA od 0 W do 2,665 kW CMC 0,80 mW/VA\n120 V do 130 V; 800 mA do 1 A od 0 W do 2,665 kW CMC 0,65 mW/VA\n120 V do 130 V; 1 A do 1,3 A od 0 W do 2,665 kW CMC 0,56 mW/VA\n120 V do 130 V; 1,3 A do 2 A od 0 W do 2,665 kW CMC 0,76 mW/VA\n120 V do 130 V; 2 A do 2,6 A od 0 W do 2,665 kW CMC 0,56 mW/VA\n120 V do 130 V; 2,6 A do 4 A od 0 W do 2,665 kW CMC 0,76 mW/VA\n120 V do 130 V; 4 A do 5,2 A od 0 W do 2,665 kW CMC 0,56 mW/VA\n120 V do 130 V; 5,2 A do 8 A od 0 W do 2,665 kW CMC 0,76 mW/VA\n120 V do 130 V; 8 A do 10 A od 0 W do 2,665 kW CMC 0,56 mW/VA\n120 V do 130 V; 10 A do 15 A od 0 W do 2,665 kW CMC 0,78 mW/VA\n120 V do 130 V; 15 A do 20,5 A od 0 W do 2,665 kW CMC 0,59 mW/VA\n130 V do 230 V; 150 mA do 200 mA od 0 W do 4,715 kW CMC 1,4 mW/VA\n130 V do 230 V; 200 mA do 250 mA od 0 W do 4,715 kW CMC 1,1 mW/VA\n130 V do 230 V; 250 mA do 300 mA od 0 W do 4,715 kW CMC 0,90 mW/VA\n130 V do 230 V; 300 mA do 400 mA od 0 W do 4,715 kW CMC 1,4 mW/VA\n130 V do 230 V; 400 mA do 500 mA od 0 W do 4,715 kW CMC 1,1 mW/VA\n130 V do 230 V; 500 mA do 600 mA od 0 W do 4,715 kW CMC 0,90 mW/VA\n130 V do 230 V; 600 mA do 800 mA od 0 W do 4,715 kW CMC 1,4 mW/VA\n130 V do 230 V; 800 mA do 1 A od 0 W do 4,715 kW CMC 1,1 mW/VA\n130 V do 230 V; 1 A do 1,3 A od 0 W do 4,715 kW CMC 0,90 mW/VA\n130 V do 230 V; 1,3 A do 2 A od 0 W do 4,715 kW CMC 1,3 mW/VA\n130 V do 230 V; 2 A do 2,6 A od 0 W do 4,715 kW CMC 0,90 mW/VA\n130 V do 230 V; 2,6 A do 4 A od 0 W do 4,715 kW CMC 1,3 mW/VA\n130 V do 230 V; 4 A do 5,2 A od 0 W do 4,715 kW CMC 0,90 mW/VA\n130 V do 230 V; 5,2 A do 8 A od 0 W do 4,715 kW CMC 1,3 mW/VA\n130 V do 230 V; 8 A do 10 A od 0 W do 4,715 kW CMC 0,90 mW/VA\n130 V do 230 V; 10 A do 15 A od 0 W do 4,715 kW CMC 1,4 mW/VA\n130 V do 230 V; 15 A do 20,5 A od 0 W do 4,715 kW CMC 0,95 mW/VA\n230 V do 270 V; 150 mA do 200 mA od 0 W do 5,535 kW CMC 0,80 mW/VA\n230 V do 270 V; 200 mA do 300 mA od 0 W do 5,535 kW CMC 0,65 mW/VA\n230 V do 270 V; 300 mA do 400 mA od 0 W do 5,535 kW CMC 0,81 mW/VA\n230 V do 270 V; 400 mA do 600 mA od 0 W do 5,535 kW CMC 0,65 mW/VA\n230 V do 270 V; 600 mA do 800 mA od 0 W do 5,535 kW CMC 0,80 mW/VA\n230 V do 270 V; 800 mA do 1 A od 0 W do 5,535 kW CMC 0,65 mW/VA\n230 V do 270 V; 1 A do 1,3 A od 0 W do 5,535 kW CMC 0,56 mW/VA\n230 V do 270 V; 1,3 A do 2 A od 0 W do 5,535 kW CMC 0,76 mW/VA\n230 V do 270 V; 2 A do 2,6 A od 0 W do 5,535 kW CMC 0,56 mW/VA\n230 V do 270 V; 2,6 A do 4 A od 0 W do 5,535 kW CMC 0,76 mW/VA\n230 V do 270 V; 4 A do 5,2 A od 0 W do 5,535 kW CMC 0,56 mW/VA\n230 V do 270 V; 5,2 A do 8 A od 0 W do 5,535 kW CMC 0,76 mW/VA\n230 V do 270 V; 8 A do 10 A od 0 W do 5,535 kW CMC 0,56 mW/VA\n230 V do 270 V; 10 A do 15 A od 0 W do 5,535 kW CMC 0,78 mW/VA\n230 V do 270 V; 15 A do 20,5 A od 0 W do 5,535 kW CMC 0,59 mW/VA\n270 V do 540 V; 150 mA do 200 mA od 0 W do 11,07 kW CMC 1,4 mW/VA\n270 V do 540 V; 200 mA do 250 mA od 0 W do 11,07 kW CMC 1,1 mW/VA\n270 V do 540 V; 250 mA do 300 mA od 0 W do 11,07 kW CMC 0,90 mW/VA\n270 V do 540 V; 300 mA do 400 mA od 0 W do 11,07 kW CMC 1,4 mW/VA\n270 V do 540 V; 400 mA do 500 mA od 0 W do 11,07 kW CMC 1,1 mW/VA\n270 V do 540 V; 500 mA do 600 mA od 0 W do 11,07 kW CMC 0,90 mW/VA\n270 V do 540 V; 600 mA do 800 mA od 0 W do 11,07 kW CMC 1,4 mW/VA\n270 V do 540 V; 800 mA do 1 A od 0 W do 11,07 kW CMC 1,1 mW/VA\n270 V do 540 V; 1 A do 1,3 A od 0 W do 11,07 kW CMC 0,90 mW/VA\n270 V do 540 V; 1,3 A do 2 A od 0 W do 11,07 kW CMC 1,3 mW/VA\n270 V do 540 V; 2 A do 2,6 A od 0 W do 11,07 kW CMC 0,90 mW/VA\n270 V do 540 V; 2,6 A do 4 A od 0 W do 11,07 kW CMC 1,3 mW/VA\n270 V do 540 V; 4 A do 5,2 A od 0 W do 11,07 kW CMC 0,90 mW/VA\n270 V do 540 V; 5,2 A do 8 A od 0 W do 11,07 kW CMC 1,3 mW/VA\n270 V do 540 V; 8 A do 10 A od 0 W do 11,07 kW CMC 0,90 mW/VA\n270 V do 540 V; 10 A do 15 A od 0 W do 11,07 kW CMC 1,4 mW/VA\n270 V do 540 V; 15 A do 20,5 A od 0 W do 11,07 kW CMC 0,95 mW/VA\n540 V do 560 V; 150 mA do 200 mA od 0 W do 11,48 kW CMC 0,80 mW/VA\n540 V do 560 V; 200 mA do 300 mA od 0 W do 11,48 kW CMC 0,65 mW/VA\n540 V do 560 V; 300 mA do 400 mA od 0 W do 11,48 kW CMC 0,81 mW/VA\n540 V do 560 V; 400 mA do 600 mA od 0 W do 11,48 kW CMC 0,65 mW/VA\n540 V do 560 V; 600 mA do 800 mA od 0 W do 11,48 kW CMC 0,80 mW/VA\n540 V do 560 V; 800 mA do 1 A od 0 W do 11,48 kW CMC 0,65 mW/VA\n540 V do 560 V; 1 A do 1,3 A od 0 W do 11,48 kW CMC 0,56 mW/VA\n540 V do 560 V; 1,3 A do 2 A od 0 W do 11,48 kW CMC 0,76 mW/VA\n540 V do 560 V; 2 A do 2,6 A od 0 W do 11,48 kW CMC 0,56 mW/VA\n540 V do 560 V; 2,6 A do 4 A od 0 W do 11,48 kW CMC 0,76 mW/VA\n540 V do 560 V; 4 A do 5,2 A od 0 W do 11,48 kW CMC 0,56 mW/VA\n540 V do 560 V; 5,2 A do 8 A od 0 W do 11,48 kW CMC 0,76 mW/VA\n540 V do 560 V; 8 A do 10 A od 0 W do 11,48 kW CMC 0,56 mW/VA\n540 V do 560 V; 10 A do 15 A od 0 W do 11,48 kW CMC 0,78 mW/VA\n540 V do 560 V; 15 A do 20,5 A od 0 W do 11,48 kW CMC 0,59 mW/VA\n560 V do 700 V; 150 mA do 200 mA od 0 W do 14,35 kW CMC 1,4 mW/VA\n560 V do 700 V; 200 mA do 250 mA od 0 W do 14,35 kW CMC 1,1 mW/VA\n560 V do 700 V; 250 mA do 300 mA od 0 W do 14,35 kW CMC 0,90 mW/VA\n560 V do 700 V; 300 mA do 400 mA od 0 W do 14,35 kW CMC 1,4 mW/VA\n560 V do 700 V; 400 mA do 500 mA od 0 W do 14,35 kW CMC 1,1 mW/VA\n560 V do 700 V; 500 mA do 600 mA od 0 W do 14,35 kW CMC 0,90 mW/VA\n560 V do 700 V; 600 mA do 800 mA od 0 W do 14,35 kW CMC 1,4 mW/VA\n560 V do 700 V; 800 mA do 1 A od 0 W do 14,35 kW CMC 1,1 mW/VA\n560 V do 700 V; 1 A do 1,3 A od 0 W do 14,35 kW CMC 0,90 mW/VA\n560 V do 700 V; 1,3 A do 2 A od 0 W do 14,35 kW CMC 1,3 mW/VA\n560 V do 700 V; 2 A do 2,6 A od 0 W do 14,35 kW CMC 0,90 mW/VA\n560 V do 700 V; 2,6 A do 4 A od 0 W do 14,35 kW CMC 1,3 mW/VA\n560 V do 700 V; 4 A do 5,2 A od 0 W do 14,35 kW CMC 0,90 mW/VA\n560 V do 700 V; 5,2 A do 8 A od 0 W do 14,35 kW CMC 1,3 mW/VA\n560 V do 700 V; 8 A do 10 A od 0 W do 14,35 kW CMC 0,90 mW/VA\n560 V do 700 V; 10 A do 15 A od 0 W do 14,35 kW CMC 1,4 mW/VA\n560 V do 700 V; 15 A do 20,5 A od 0 W do 14,35 kW CMC 0,95 mW/VA\n700 V do 720 V; 150 mA do 200 mA od 0 W do 14,76 kW CMC 1,1 mW/VA\n700 V do 720 V; 200 mA do 250 mA od 0 W do 14,76 kW CMC 0,80 mW/VA\n700 V do 720 V; 250 mA do 300 mA od 0 W do 14,76 kW CMC 0,68 mW/VA\n700 V do 720 V; 300 mA do 400 mA od 0 W do 14,76 kW CMC 1,0 mW/VA\n700 V do 720 V; 400 mA do 500 mA od 0 W do 14,76 kW CMC 0,80 mW/VA\n700 V do 720 V; 500 mA do 600 mA od 0 W do 14,76 kW CMC 0,68 mW/VA\n700 V do 720 V; 600 mA do 800 mA od 0 W do 14,76 kW CMC 1,0 mW/VA\n700 V do 720 V; 800 mA do 1 A od 0 W do 14,76 kW CMC 0,80 mW/VA\n700 V do 720 V; 1 A do 1,3 A od 0 W do 14,76 kW CMC 0,68 mW/VA\n700 V do 720 V; 1,3 A do 2 A od 0 W do 14,76 kW CMC 0,94 mW/VA\n700 V do 720 V; 2 A do 2,6 A od 0 W do 14,76 kW CMC 0,68 mW/VA\n700 V do 720 V; 2,6 A do 4 A od 0 W do 14,76 kW CMC 0,94 mW/VA\n700 V do 720 V; 4 A do 5,2 A od 0 W do 14,76 kW CMC 0,68 mW/VA\n700 V do 720 V; 5,2 A do 8 A od 0 W do 14,76 kW CMC 0,94 mW/VA\n700 V do 720 V; 8 A do 10 A od 0 W do 14,76 kW CMC 0,68 mW/VA\n700 V do 720 V; 10 A do 15 A od 0 W do 14,76 kW CMC 0,97 mW/VA\n700 V do 720 V; 15 A do 20,5 A od 0 W do 14,76 kW CMC 0,71 mW/VA\nPomiar bezpośredni miernikiem mocy","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego jednofazowa / Źródła (f: 45 Hz do 65 Hz, PF: 0 do 1) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni miernikiem mocy 25 V do 30 V; 150 mA do 200 mA od 0 W do 615 W CMC 0,90 mW/VA 25 V do 30 V; 200 mA do 300 mA od 0 W do 615 W CMC 0,72 mW/VA 25 V do 30 V; 300 mA do 400 mA od 0 W do 615 W CMC 0,90 mW/VA 25 V do 30 V; 400 mA do 600 mA od 0 W do 615 W CMC 0,72 mW/VA 25 V do 30 V; 600 mA do 800 mA od 0 W do 615 W CMC 0,90 mW/VA 25 V do 30 V; 800 mA do 1,3 A od 0 W do 615 W CMC 0,72 mW/VA 25 V do 30 V; 1,3 A do 2 A od 0 W do 615 W CMC 0,85 mW/VA 25 V do 30 V; 2 A do 2,6 A od 0 W do 615 W CMC 0,62 mW/VA 25 V do 30 V; 2,6 A do 4 A od 0 W do 615 W CMC 0,85 mW/VA 25 V do 30 V; 4 A do 5,2 A od 0 W do 615 W CMC 0,62 mW/VA 25 V do 30 V; 5,2 A do 8 A od 0 W do 615 W CMC 0,85 mW/VA 25 V do 30 V; 8 A do 10 A od 0 W do 615 W CMC 0,62 mW/VA 25 V do 30 V; 10 A do 15 A od 0 W do 615 W CMC 0,87 mW/VA 25 V do 30 V; 15 A do 20,5 A od 0 W do 615 W CMC 0,65 mW/VA 30 V do 50 V; 150 mA do 200 mA od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 200 mA do 250 mA od 0 W do 1,025 kW CMC 1,1 mW/VA 30 V do 50 V; 250 mA do 300 mA od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 300 mA do 400 mA od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 400 mA do 500 mA od 0 W do 1,025 kW CMC 1,1 mW/VA 30 V do 50 V; 500 mA do 600 mA od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 600 mA do 800 mA od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 800 mA do 1 A od 0 W do 1,025 kW CMC 1,1 mW/VA 30 V do 50 V; 1 A do 1,3 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 1,3 A do 2 A od 0 W do 1,025 kW CMC 1,3 mW/VA 30 V do 50 V; 2 A do 2,6 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 2,6 A do 4 A od 0 W do 1,025 kW CMC 1,3 mW/VA 30 V do 50 V; 4 A do 5,2 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 5,2 A do 8 A od 0 W do 1,025 kW CMC 1,3 mW/VA 30 V do 50 V; 8 A do 10 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 10 A do 15 A od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 15 A do 20,5 A od 0 W do 1,025 kW CMC 0,95 mW/VA 50 V do 60 V; 150 mA do 200 mA od 0 W do 1,23 kW CMC 0,90 mW/VA 50 V do 60 V; 200 mA do 300 mA od 0 W do 1,23 kW CMC 0,72 mW/VA 50 V do 60 V; 300 mA do 400 mA od 0 W do 1,23 kW CMC 0,90 mW/VA 50 V do 60 V; 400 mA do 600 mA od 0 W do 1,23 kW CMC 0,72 mW/VA 50 V do 60 V; 600 mA do 800 mA od 0 W do 1,23 kW CMC 0,90 mW/VA 50 V do 60 V; 800 mA do 1,3 A od 0 W do 1,23 kW CMC 0,72 mW/VA 50 V do 60 V; 1,3 A do 2 A od 0 W do 1,23 kW CMC 0,85 mW/VA 50 V do 60 V; 2 A do 2,6 A od 0 W do 1,23 kW CMC 0,62 mW/VA 50 V do 60 V; 2,6 A do 4 A od 0 W do 1,23 kW CMC 0,85 mW/VA 50 V do 60 V; 4 A do 5,2 A od 0 W do 1,23 kW CMC 0,62 mW/VA 50 V do 60 V; 5,2 A do 8 A od 0 W do 1,23 kW CMC 0,85 mW/VA 50 V do 60 V; 8 A do 10 A od 0 W do 1,23 kW CMC 0,62 mW/VA 50 V do 60 V; 10 A do 15 A od 0 W do 1,23 kW CMC 0,87 mW/VA 50 V do 60 V; 15 A do 20,5 A od 0 W do 1,23 kW CMC 0,65 mW/VA 60 V do 120 V; 150 mA do 200 mA od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 200 mA do 250 mA od 0 W do 2,46 kW CMC 1,1 mW/VA 60 V do 120 V; 250 mA do 300 mA od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 300 mA do 400 mA od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 400 mA do 500 mA od 0 W do 2,46 kW CMC 1,1 mW/VA 60 V do 120 V; 500 mA do 600 mA od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 600 mA do 800 mA od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 800 mA do 1 A od 0 W do 2,46 kW CMC 1,1 mW/VA 60 V do 120 V; 1 A do 1,3 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 1,3 A do 2 A od 0 W do 2,46 kW CMC 1,3 mW/VA 60 V do 120 V; 2 A do 2,6 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 2,6 A do 4 A od 0 W do 2,46 kW CMC 1,3 mW/VA 60 V do 120 V; 4 A do 5,2 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 5,2 A do 8 A od 0 W do 2,46 kW CMC 1,3 mW/VA 60 V do 120 V; 8 A do 10 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 10 A do 15 A od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 15 A do 20,5 A od 0 W do 2,46 kW CMC 0,95 mW/VA 120 V do 130 V; 150 mA do 200 mA od 0 W do 2,665 kW CMC 0,80 mW/VA 120 V do 130 V; 200 mA do 300 mA od 0 W do 2,665 kW CMC 0,65 mW/VA 120 V do 130 V; 300 mA do 400 mA od 0 W do 2,665 kW CMC 0,81 mW/VA 120 V do 130 V; 400 mA do 600 mA od 0 W do 2,665 kW CMC 0,65 mW/VA 120 V do 130 V; 600 mA do 800 mA od 0 W do 2,665 kW CMC 0,80 mW/VA 120 V do 130 V; 800 mA do 1 A od 0 W do 2,665 kW CMC 0,65 mW/VA 120 V do 130 V; 1 A do 1,3 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 1,3 A do 2 A od 0 W do 2,665 kW CMC 0,76 mW/VA 120 V do 130 V; 2 A do 2,6 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 2,6 A do 4 A od 0 W do 2,665 kW CMC 0,76 mW/VA 120 V do 130 V; 4 A do 5,2 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 5,2 A do 8 A od 0 W do 2,665 kW CMC 0,76 mW/VA 120 V do 130 V; 8 A do 10 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 10 A do 15 A od 0 W do 2,665 kW CMC 0,78 mW/VA 120 V do 130 V; 15 A do 20,5 A od 0 W do 2,665 kW CMC 0,59 mW/VA 130 V do 230 V; 150 mA do 200 mA od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 200 mA do 250 mA od 0 W do 4,715 kW CMC 1,1 mW/VA 130 V do 230 V; 250 mA do 300 mA od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 300 mA do 400 mA od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 400 mA do 500 mA od 0 W do 4,715 kW CMC 1,1 mW/VA 130 V do 230 V; 500 mA do 600 mA od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 600 mA do 800 mA od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 800 mA do 1 A od 0 W do 4,715 kW CMC 1,1 mW/VA 130 V do 230 V; 1 A do 1,3 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 1,3 A do 2 A od 0 W do 4,715 kW CMC 1,3 mW/VA 130 V do 230 V; 2 A do 2,6 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 2,6 A do 4 A od 0 W do 4,715 kW CMC 1,3 mW/VA 130 V do 230 V; 4 A do 5,2 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 5,2 A do 8 A od 0 W do 4,715 kW CMC 1,3 mW/VA 130 V do 230 V; 8 A do 10 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 10 A do 15 A od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 15 A do 20,5 A od 0 W do 4,715 kW CMC 0,95 mW/VA 230 V do 270 V; 150 mA do 200 mA od 0 W do 5,535 kW CMC 0,80 mW/VA 230 V do 270 V; 200 mA do 300 mA od 0 W do 5,535 kW CMC 0,65 mW/VA 230 V do 270 V; 300 mA do 400 mA od 0 W do 5,535 kW CMC 0,81 mW/VA 230 V do 270 V; 400 mA do 600 mA od 0 W do 5,535 kW CMC 0,65 mW/VA 230 V do 270 V; 600 mA do 800 mA od 0 W do 5,535 kW CMC 0,80 mW/VA 230 V do 270 V; 800 mA do 1 A od 0 W do 5,535 kW CMC 0,65 mW/VA 230 V do 270 V; 1 A do 1,3 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 1,3 A do 2 A od 0 W do 5,535 kW CMC 0,76 mW/VA 230 V do 270 V; 2 A do 2,6 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 2,6 A do 4 A od 0 W do 5,535 kW CMC 0,76 mW/VA 230 V do 270 V; 4 A do 5,2 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 5,2 A do 8 A od 0 W do 5,535 kW CMC 0,76 mW/VA 230 V do 270 V; 8 A do 10 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 10 A do 15 A od 0 W do 5,535 kW CMC 0,78 mW/VA 230 V do 270 V; 15 A do 20,5 A od 0 W do 5,535 kW CMC 0,59 mW/VA 270 V do 540 V; 150 mA do 200 mA od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 200 mA do 250 mA od 0 W do 11,07 kW CMC 1,1 mW/VA 270 V do 540 V; 250 mA do 300 mA od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 300 mA do 400 mA od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 400 mA do 500 mA od 0 W do 11,07 kW CMC 1,1 mW/VA 270 V do 540 V; 500 mA do 600 mA od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 600 mA do 800 mA od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 800 mA do 1 A od 0 W do 11,07 kW CMC 1,1 mW/VA 270 V do 540 V; 1 A do 1,3 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 1,3 A do 2 A od 0 W do 11,07 kW CMC 1,3 mW/VA 270 V do 540 V; 2 A do 2,6 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 2,6 A do 4 A od 0 W do 11,07 kW CMC 1,3 mW/VA 270 V do 540 V; 4 A do 5,2 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 5,2 A do 8 A od 0 W do 11,07 kW CMC 1,3 mW/VA 270 V do 540 V; 8 A do 10 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 10 A do 15 A od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 15 A do 20,5 A od 0 W do 11,07 kW CMC 0,95 mW/VA 540 V do 560 V; 150 mA do 200 mA od 0 W do 11,48 kW CMC 0,80 mW/VA 540 V do 560 V; 200 mA do 300 mA od 0 W do 11,48 kW CMC 0,65 mW/VA 540 V do 560 V; 300 mA do 400 mA od 0 W do 11,48 kW CMC 0,81 mW/VA 540 V do 560 V; 400 mA do 600 mA od 0 W do 11,48 kW CMC 0,65 mW/VA 540 V do 560 V; 600 mA do 800 mA od 0 W do 11,48 kW CMC 0,80 mW/VA 540 V do 560 V; 800 mA do 1 A od 0 W do 11,48 kW CMC 0,65 mW/VA 540 V do 560 V; 1 A do 1,3 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 1,3 A do 2 A od 0 W do 11,48 kW CMC 0,76 mW/VA 540 V do 560 V; 2 A do 2,6 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 2,6 A do 4 A od 0 W do 11,48 kW CMC 0,76 mW/VA 540 V do 560 V; 4 A do 5,2 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 5,2 A do 8 A od 0 W do 11,48 kW CMC 0,76 mW/VA 540 V do 560 V; 8 A do 10 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 10 A do 15 A od 0 W do 11,48 kW CMC 0,78 mW/VA 540 V do 560 V; 15 A do 20,5 A od 0 W do 11,48 kW CMC 0,59 mW/VA 560 V do 700 V; 150 mA do 200 mA od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 200 mA do 250 mA od 0 W do 14,35 kW CMC 1,1 mW/VA 560 V do 700 V; 250 mA do 300 mA od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 300 mA do 400 mA od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 400 mA do 500 mA od 0 W do 14,35 kW CMC 1,1 mW/VA 560 V do 700 V; 500 mA do 600 mA od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 600 mA do 800 mA od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 800 mA do 1 A od 0 W do 14,35 kW CMC 1,1 mW/VA 560 V do 700 V; 1 A do 1,3 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 1,3 A do 2 A od 0 W do 14,35 kW CMC 1,3 mW/VA 560 V do 700 V; 2 A do 2,6 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 2,6 A do 4 A od 0 W do 14,35 kW CMC 1,3 mW/VA 560 V do 700 V; 4 A do 5,2 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 5,2 A do 8 A od 0 W do 14,35 kW CMC 1,3 mW/VA 560 V do 700 V; 8 A do 10 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 10 A do 15 A od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 15 A do 20,5 A od 0 W do 14,35 kW CMC 0,95 mW/VA 700 V do 720 V; 150 mA do 200 mA od 0 W do 14,76 kW CMC 1,1 mW/VA 700 V do 720 V; 200 mA do 250 mA od 0 W do 14,76 kW CMC 0,80 mW/VA 700 V do 720 V; 250 mA do 300 mA od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 300 mA do 400 mA od 0 W do 14,76 kW CMC 1,0 mW/VA 700 V do 720 V; 400 mA do 500 mA od 0 W do 14,76 kW CMC 0,80 mW/VA 700 V do 720 V; 500 mA do 600 mA od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 600 mA do 800 mA od 0 W do 14,76 kW CMC 1,0 mW/VA 700 V do 720 V; 800 mA do 1 A od 0 W do 14,76 kW CMC 0,80 mW/VA 700 V do 720 V; 1 A do 1,3 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 1,3 A do 2 A od 0 W do 14,76 kW CMC 0,94 mW/VA 700 V do 720 V; 2 A do 2,6 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 2,6 A do 4 A od 0 W do 14,76 kW CMC 0,94 mW/VA 700 V do 720 V; 4 A do 5,2 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 5,2 A do 8 A od 0 W do 14,76 kW CMC 0,94 mW/VA 700 V do 720 V; 8 A do 10 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 10 A do 15 A od 0 W do 14,76 kW CMC 0,97 mW/VA 700 V do 720 V; 15 A do 20,5 A od 0 W do 14,76 kW CMC 0,71 mW/VA Střídavý činný výkon jednofázový / Zdroje (f: 45 Hz až 65 Hz, PF: 0 až 1) Kalibrace – elektrické veličiny Přímé měření měřidlem výkonu 25 V až 30 V; 150 mA až 200 mA 0 W až 615 W CMC 0,90 mW/VA 25 V až 30 V; 200 mA až 300 mA 0 W až 615 W CMC 0,72 mW/VA 25 V až 30 V; 300 mA až 400 mA 0 W až 615 W CMC 0,90 mW/VA 25 V až 30 V; 400 mA až 600 mA 0 W až 615 W CMC 0,72 mW/VA 25 V až 30 V; 600 mA až 800 mA 0 W až 615 W CMC 0,90 mW/VA 25 V až 30 V; 800 mA až 1,3 A 0 W až 615 W CMC 0,72 mW/VA 25 V až 30 V; 1,3 A až 2 A 0 W až 615 W CMC 0,85 mW/VA 25 V až 30 V; 2 A až 2,6 A 0 W až 615 W CMC 0,62 mW/VA 25 V až 30 V; 2,6 A až 4 A 0 W až 615 W CMC 0,85 mW/VA 25 V až 30 V; 4 A až 5,2 A 0 W až 615 W CMC 0,62 mW/VA 25 V až 30 V; 5,2 A až 8 A 0 W až 615 W CMC 0,85 mW/VA 25 V až 30 V; 8 A až 10 A 0 W až 615 W CMC 0,62 mW/VA 25 V až 30 V; 10 A až 15 A 0 W až 615 W CMC 0,87 mW/VA 25 V až 30 V; 15 A až 20,5 A 0 W až 615 W CMC 0,65 mW/VA 30 V až 50 V; 150 mA až 200 mA 0 W až 1,025 kW CMC 1,4 mW/VA 30 V až 50 V; 200 mA až 250 mA 0 W až 1,025 kW CMC 1,1 mW/VA 30 V až 50 V; 250 mA až 300 mA 0 W až 1,025 kW CMC 0,90 mW/VA 30 V až 50 V; 300 mA až 400 mA 0 W až 1,025 kW CMC 1,4 mW/VA 30 V až 50 V; 400 mA až 500 mA 0 W až 1,025 kW CMC 1,1 mW/VA 30 V až 50 V; 500 mA až 600 mA 0 W až 1,025 kW CMC 0,90 mW/VA 30 V až 50 V; 600 mA až 800 mA 0 W až 1,025 kW CMC 1,4 mW/VA 30 V až 50 V; 800 mA až 1 A 0 W až 1,025 kW CMC 1,1 mW/VA 30 V až 50 V; 1 A až 1,3 A 0 W až 1,025 kW CMC 0,90 mW/VA 30 V až 50 V; 1,3 A až 2 A 0 W až 1,025 kW CMC 1,3 mW/VA 30 V až 50 V; 2 A až 2,6 A 0 W až 1,025 kW CMC 0,90 mW/VA 30 V až 50 V; 2,6 A až 4 A 0 W až 1,025 kW CMC 1,3 mW/VA 30 V až 50 V; 4 A až 5,2 A 0 W až 1,025 kW CMC 0,90 mW/VA 30 V až 50 V; 5,2 A až 8 A 0 W až 1,025 kW CMC 1,3 mW/VA 30 V až 50 V; 8 A až 10 A 0 W až 1,025 kW CMC 0,90 mW/VA 30 V až 50 V; 10 A až 15 A 0 W až 1,025 kW CMC 1,4 mW/VA 30 V až 50 V; 15 A až 20,5 A 0 W až 1,025 kW CMC 0,95 mW/VA 50 V až 60 V; 150 mA až 200 mA 0 W až 1,23 kW CMC 0,90 mW/VA 50 V až 60 V; 200 mA až 300 mA 0 W až 1,23 kW CMC 0,72 mW/VA 50 V až 60 V; 300 mA až 400 mA 0 W až 1,23 kW CMC 0,90 mW/VA 50 V až 60 V; 400 mA až 600 mA 0 W až 1,23 kW CMC 0,72 mW/VA 50 V až 60 V; 600 mA až 800 mA 0 W až 1,23 kW CMC 0,90 mW/VA 50 V až 60 V; 800 mA až 1,3 A 0 W až 1,23 kW CMC 0,72 mW/VA 50 V až 60 V; 1,3 A až 2 A 0 W až 1,23 kW CMC 0,85 mW/VA 50 V až 60 V; 2 A až 2,6 A 0 W až 1,23 kW CMC 0,62 mW/VA 50 V až 60 V; 2,6 A až 4 A 0 W až 1,23 kW CMC 0,85 mW/VA 50 V až 60 V; 4 A až 5,2 A 0 W až 1,23 kW CMC 0,62 mW/VA 50 V až 60 V; 5,2 A až 8 A 0 W až 1,23 kW CMC 0,85 mW/VA 50 V až 60 V; 8 A až 10 A 0 W až 1,23 kW CMC 0,62 mW/VA 50 V až 60 V; 10 A až 15 A 0 W až 1,23 kW CMC 0,87 mW/VA 50 V až 60 V; 15 A až 20,5 A 0 W až 1,23 kW CMC 0,65 mW/VA 60 V až 120 V; 150 mA až 200 mA 0 W až 2,46 kW CMC 1,4 mW/VA 60 V až 120 V; 200 mA až 250 mA 0 W až 2,46 kW CMC 1,1 mW/VA 60 V až 120 V; 250 mA až 300 mA 0 W až 2,46 kW CMC 0,90 mW/VA 60 V až 120 V; 300 mA až 400 mA 0 W až 2,46 kW CMC 1,4 mW/VA 60 V až 120 V; 400 mA až 500 mA 0 W až 2,46 kW CMC 1,1 mW/VA 60 V až 120 V; 500 mA až 600 mA 0 W až 2,46 kW CMC 0,90 mW/VA 60 V až 120 V; 600 mA až 800 mA 0 W až 2,46 kW CMC 1,4 mW/VA 60 V až 120 V; 800 mA až 1 A 0 W až 2,46 kW CMC 1,1 mW/VA 60 V až 120 V; 1 A až 1,3 A 0 W až 2,46 kW CMC 0,90 mW/VA 60 V až 120 V; 1,3 A až 2 A 0 W až 2,46 kW CMC 1,3 mW/VA 60 V až 120 V; 2 A až 2,6 A 0 W až 2,46 kW CMC 0,90 mW/VA 60 V až 120 V; 2,6 A až 4 A 0 W až 2,46 kW CMC 1,3 mW/VA 60 V až 120 V; 4 A až 5,2 A 0 W až 2,46 kW CMC 0,90 mW/VA 60 V až 120 V; 5,2 A až 8 A 0 W až 2,46 kW CMC 1,3 mW/VA 60 V až 120 V; 8 A až 10 A 0 W až 2,46 kW CMC 0,90 mW/VA 60 V až 120 V; 10 A až 15 A 0 W až 2,46 kW CMC 1,4 mW/VA 60 V až 120 V; 15 A až 20,5 A 0 W až 2,46 kW CMC 0,95 mW/VA 120 V až 130 V; 150 mA až 200 mA 0 W až 2,665 kW CMC 0,80 mW/VA 120 V až 130 V; 200 mA až 300 mA 0 W až 2,665 kW CMC 0,65 mW/VA 120 V až 130 V; 300 mA až 400 mA 0 W až 2,665 kW CMC 0,81 mW/VA 120 V až 130 V; 400 mA až 600 mA 0 W až 2,665 kW CMC 0,65 mW/VA 120 V až 130 V; 600 mA až 800 mA 0 W až 2,665 kW CMC 0,80 mW/VA 120 V až 130 V; 800 mA až 1 A 0 W až 2,665 kW CMC 0,65 mW/VA 120 V až 130 V; 1 A až 1,3 A 0 W až 2,665 kW CMC 0,56 mW/VA 120 V až 130 V; 1,3 A až 2 A 0 W až 2,665 kW CMC 0,76 mW/VA 120 V až 130 V; 2 A až 2,6 A 0 W až 2,665 kW CMC 0,56 mW/VA 120 V až 130 V; 2,6 A až 4 A 0 W až 2,665 kW CMC 0,76 mW/VA 120 V až 130 V; 4 A až 5,2 A 0 W až 2,665 kW CMC 0,56 mW/VA 120 V až 130 V; 5,2 A až 8 A 0 W až 2,665 kW CMC 0,76 mW/VA 120 V až 130 V; 8 A až 10 A 0 W až 2,665 kW CMC 0,56 mW/VA 120 V až 130 V; 10 A až 15 A 0 W až 2,665 kW CMC 0,78 mW/VA 120 V až 130 V; 15 A až 20,5 A 0 W až 2,665 kW CMC 0,59 mW/VA 130 V až 230 V; 150 mA až 200 mA 0 W až 4,715 kW CMC 1,4 mW/VA 130 V až 230 V; 200 mA až 250 mA 0 W až 4,715 kW CMC 1,1 mW/VA 130 V až 230 V; 250 mA až 300 mA 0 W až 4,715 kW CMC 0,90 mW/VA 130 V až 230 V; 300 mA až 400 mA 0 W až 4,715 kW CMC 1,4 mW/VA 130 V až 230 V; 400 mA až 500 mA 0 W až 4,715 kW CMC 1,1 mW/VA 130 V až 230 V; 500 mA až 600 mA 0 W až 4,715 kW CMC 0,90 mW/VA 130 V až 230 V; 600 mA až 800 mA 0 W až 4,715 kW CMC 1,4 mW/VA 130 V až 230 V; 800 mA až 1 A 0 W až 4,715 kW CMC 1,1 mW/VA 130 V až 230 V; 1 A až 1,3 A 0 W až 4,715 kW CMC 0,90 mW/VA 130 V až 230 V; 1,3 A až 2 A 0 W až 4,715 kW CMC 1,3 mW/VA 130 V až 230 V; 2 A až 2,6 A 0 W až 4,715 kW CMC 0,90 mW/VA 130 V až 230 V; 2,6 A až 4 A 0 W až 4,715 kW CMC 1,3 mW/VA 130 V až 230 V; 4 A až 5,2 A 0 W až 4,715 kW CMC 0,90 mW/VA 130 V až 230 V; 5,2 A až 8 A 0 W až 4,715 kW CMC 1,3 mW/VA 130 V až 230 V; 8 A až 10 A 0 W až 4,715 kW CMC 0,90 mW/VA 130 V až 230 V; 10 A až 15 A 0 W až 4,715 kW CMC 1,4 mW/VA 130 V až 230 V; 15 A až 20,5 A 0 W až 4,715 kW CMC 0,95 mW/VA 230 V až 270 V; 150 mA až 200 mA 0 W až 5,535 kW CMC 0,80 mW/VA 230 V až 270 V; 200 mA až 300 mA 0 W až 5,535 kW CMC 0,65 mW/VA 230 V až 270 V; 300 mA až 400 mA 0 W až 5,535 kW CMC 0,81 mW/VA 230 V až 270 V; 400 mA až 600 mA 0 W až 5,535 kW CMC 0,65 mW/VA 230 V až 270 V; 600 mA až 800 mA 0 W až 5,535 kW CMC 0,80 mW/VA 230 V až 270 V; 800 mA až 1 A 0 W až 5,535 kW CMC 0,65 mW/VA 230 V až 270 V; 1 A až 1,3 A 0 W až 5,535 kW CMC 0,56 mW/VA 230 V až 270 V; 1,3 A až 2 A 0 W až 5,535 kW CMC 0,76 mW/VA 230 V až 270 V; 2 A až 2,6 A 0 W až 5,535 kW CMC 0,56 mW/VA 230 V až 270 V; 2,6 A až 4 A 0 W až 5,535 kW CMC 0,76 mW/VA 230 V až 270 V; 4 A až 5,2 A 0 W až 5,535 kW CMC 0,56 mW/VA 230 V až 270 V; 5,2 A až 8 A 0 W až 5,535 kW CMC 0,76 mW/VA 230 V až 270 V; 8 A až 10 A 0 W až 5,535 kW CMC 0,56 mW/VA 230 V až 270 V; 10 A až 15 A 0 W až 5,535 kW CMC 0,78 mW/VA 230 V až 270 V; 15 A až 20,5 A 0 W až 5,535 kW CMC 0,59 mW/VA 270 V až 540 V; 150 mA až 200 mA 0 W až 11,07 kW CMC 1,4 mW/VA 270 V až 540 V; 200 mA až 250 mA 0 W až 11,07 kW CMC 1,1 mW/VA 270 V až 540 V; 250 mA až 300 mA 0 W až 11,07 kW CMC 0,90 mW/VA 270 V až 540 V; 300 mA až 400 mA 0 W až 11,07 kW CMC 1,4 mW/VA 270 V až 540 V; 400 mA až 500 mA 0 W až 11,07 kW CMC 1,1 mW/VA 270 V až 540 V; 500 mA až 600 mA 0 W až 11,07 kW CMC 0,90 mW/VA 270 V až 540 V; 600 mA až 800 mA 0 W až 11,07 kW CMC 1,4 mW/VA 270 V až 540 V; 800 mA až 1 A 0 W až 11,07 kW CMC 1,1 mW/VA 270 V až 540 V; 1 A až 1,3 A 0 W až 11,07 kW CMC 0,90 mW/VA 270 V až 540 V; 1,3 A až 2 A 0 W až 11,07 kW CMC 1,3 mW/VA 270 V až 540 V; 2 A až 2,6 A 0 W až 11,07 kW CMC 0,90 mW/VA 270 V až 540 V; 2,6 A až 4 A 0 W až 11,07 kW CMC 1,3 mW/VA 270 V až 540 V; 4 A až 5,2 A 0 W až 11,07 kW CMC 0,90 mW/VA 270 V až 540 V; 5,2 A až 8 A 0 W až 11,07 kW CMC 1,3 mW/VA 270 V až 540 V; 8 A až 10 A 0 W až 11,07 kW CMC 0,90 mW/VA 270 V až 540 V; 10 A až 15 A 0 W až 11,07 kW CMC 1,4 mW/VA 270 V až 540 V; 15 A až 20,5 A 0 W až 11,07 kW CMC 0,95 mW/VA 540 V až 560 V; 150 mA až 200 mA 0 W až 11,48 kW CMC 0,80 mW/VA 540 V až 560 V; 200 mA až 300 mA 0 W až 11,48 kW CMC 0,65 mW/VA 540 V až 560 V; 300 mA až 400 mA 0 W až 11,48 kW CMC 0,81 mW/VA 540 V až 560 V; 400 mA až 600 mA 0 W až 11,48 kW CMC 0,65 mW/VA 540 V až 560 V; 600 mA až 800 mA 0 W až 11,48 kW CMC 0,80 mW/VA 540 V až 560 V; 800 mA až 1 A 0 W až 11,48 kW CMC 0,65 mW/VA 540 V až 560 V; 1 A až 1,3 A 0 W až 11,48 kW CMC 0,56 mW/VA 540 V až 560 V; 1,3 A až 2 A 0 W až 11,48 kW CMC 0,76 mW/VA 540 V až 560 V; 2 A až 2,6 A 0 W až 11,48 kW CMC 0,56 mW/VA 540 V až 560 V; 2,6 A až 4 A 0 W až 11,48 kW CMC 0,76 mW/VA 540 V až 560 V; 4 A až 5,2 A 0 W až 11,48 kW CMC 0,56 mW/VA 540 V až 560 V; 5,2 A až 8 A 0 W až 11,48 kW CMC 0,76 mW/VA 540 V až 560 V; 8 A až 10 A 0 W až 11,48 kW CMC 0,56 mW/VA 540 V až 560 V; 10 A až 15 A 0 W až 11,48 kW CMC 0,78 mW/VA 540 V až 560 V; 15 A až 20,5 A 0 W až 11,48 kW CMC 0,59 mW/VA 560 V až 700 V; 150 mA až 200 mA 0 W až 14,35 kW CMC 1,4 mW/VA 560 V až 700 V; 200 mA až 250 mA 0 W až 14,35 kW CMC 1,1 mW/VA 560 V až 700 V; 250 mA až 300 mA 0 W až 14,35 kW CMC 0,90 mW/VA 560 V až 700 V; 300 mA až 400 mA 0 W až 14,35 kW CMC 1,4 mW/VA 560 V až 700 V; 400 mA až 500 mA 0 W až 14,35 kW CMC 1,1 mW/VA 560 V až 700 V; 500 mA až 600 mA 0 W až 14,35 kW CMC 0,90 mW/VA 560 V až 700 V; 600 mA až 800 mA 0 W až 14,35 kW CMC 1,4 mW/VA 560 V až 700 V; 800 mA až 1 A 0 W až 14,35 kW CMC 1,1 mW/VA 560 V až 700 V; 1 A až 1,3 A 0 W až 14,35 kW CMC 0,90 mW/VA 560 V až 700 V; 1,3 A až 2 A 0 W až 14,35 kW CMC 1,3 mW/VA 560 V až 700 V; 2 A až 2,6 A 0 W až 14,35 kW CMC 0,90 mW/VA 560 V až 700 V; 2,6 A až 4 A 0 W až 14,35 kW CMC 1,3 mW/VA 560 V až 700 V; 4 A až 5,2 A 0 W až 14,35 kW CMC 0,90 mW/VA 560 V až 700 V; 5,2 A až 8 A 0 W až 14,35 kW CMC 1,3 mW/VA 560 V až 700 V; 8 A až 10 A 0 W až 14,35 kW CMC 0,90 mW/VA 560 V až 700 V; 10 A až 15 A 0 W až 14,35 kW CMC 1,4 mW/VA 560 V až 700 V; 15 A až 20,5 A 0 W až 14,35 kW CMC 0,95 mW/VA 700 V až 720 V; 150 mA až 200 mA 0 W až 14,76 kW CMC 1,1 mW/VA 700 V až 720 V; 200 mA až 250 mA 0 W až 14,76 kW CMC 0,80 mW/VA 700 V až 720 V; 250 mA až 300 mA 0 W až 14,76 kW CMC 0,68 mW/VA 700 V až 720 V; 300 mA až 400 mA 0 W až 14,76 kW CMC 1,0 mW/VA 700 V až 720 V; 400 mA až 500 mA 0 W až 14,76 kW CMC 0,80 mW/VA 700 V až 720 V; 500 mA až 600 mA 0 W až 14,76 kW CMC 0,68 mW/VA 700 V až 720 V; 600 mA až 800 mA 0 W až 14,76 kW CMC 1,0 mW/VA 700 V až 720 V; 800 mA až 1 A 0 W až 14,76 kW CMC 0,80 mW/VA 700 V až 720 V; 1 A až 1,3 A 0 W až 14,76 kW CMC 0,68 mW/VA 700 V až 720 V; 1,3 A až 2 A 0 W až 14,76 kW CMC 0,94 mW/VA 700 V až 720 V; 2 A až 2,6 A 0 W až 14,76 kW CMC 0,68 mW/VA 700 V až 720 V; 2,6 A až 4 A 0 W až 14,76 kW CMC 0,94 mW/VA 700 V až 720 V; 4 A až 5,2 A 0 W až 14,76 kW CMC 0,68 mW/VA 700 V až 720 V; 5,2 A až 8 A 0 W až 14,76 kW CMC 0,94 mW/VA 700 V až 720 V; 8 A až 10 A 0 W až 14,76 kW CMC 0,68 mW/VA 700 V až 720 V; 10 A až 15 A 0 W až 14,76 kW CMC 0,97 mW/VA 700 V až 720 V; 15 A až 20,5 A 0 W až 14,76 kW CMC 0,71 mW/VA TP16 Moc czynna pradu przemiennego jednofazowa / Zrodla (f: 45 Hz do 65 Hz, PF: 0 do 1) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni miernikiem mocy 25 V do 30 V; 150 mA do 200 mA od 0 W do 615 W CMC 0,90 mW/VA 25 V do 30 V; 200 mA do 300 mA od 0 W do 615 W CMC 0,72 mW/VA 25 V do 30 V; 300 mA do 400 mA od 0 W do 615 W CMC 0,90 mW/VA 25 V do 30 V; 400 mA do 600 mA od 0 W do 615 W CMC 0,72 mW/VA 25 V do 30 V; 600 mA do 800 mA od 0 W do 615 W CMC 0,90 mW/VA 25 V do 30 V; 800 mA do 1,3 A od 0 W do 615 W CMC 0,72 mW/VA 25 V do 30 V; 1,3 A do 2 A od 0 W do 615 W CMC 0,85 mW/VA 25 V do 30 V; 2 A do 2,6 A od 0 W do 615 W CMC 0,62 mW/VA 25 V do 30 V; 2,6 A do 4 A od 0 W do 615 W CMC 0,85 mW/VA 25 V do 30 V; 4 A do 5,2 A od 0 W do 615 W CMC 0,62 mW/VA 25 V do 30 V; 5,2 A do 8 A od 0 W do 615 W CMC 0,85 mW/VA 25 V do 30 V; 8 A do 10 A od 0 W do 615 W CMC 0,62 mW/VA 25 V do 30 V; 10 A do 15 A od 0 W do 615 W CMC 0,87 mW/VA 25 V do 30 V; 15 A do 20,5 A od 0 W do 615 W CMC 0,65 mW/VA 30 V do 50 V; 150 mA do 200 mA od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 200 mA do 250 mA od 0 W do 1,025 kW CMC 1,1 mW/VA 30 V do 50 V; 250 mA do 300 mA od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 300 mA do 400 mA od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 400 mA do 500 mA od 0 W do 1,025 kW CMC 1,1 mW/VA 30 V do 50 V; 500 mA do 600 mA od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 600 mA do 800 mA od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 800 mA do 1 A od 0 W do 1,025 kW CMC 1,1 mW/VA 30 V do 50 V; 1 A do 1,3 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 1,3 A do 2 A od 0 W do 1,025 kW CMC 1,3 mW/VA 30 V do 50 V; 2 A do 2,6 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 2,6 A do 4 A od 0 W do 1,025 kW CMC 1,3 mW/VA 30 V do 50 V; 4 A do 5,2 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 5,2 A do 8 A od 0 W do 1,025 kW CMC 1,3 mW/VA 30 V do 50 V; 8 A do 10 A od 0 W do 1,025 kW CMC 0,90 mW/VA 30 V do 50 V; 10 A do 15 A od 0 W do 1,025 kW CMC 1,4 mW/VA 30 V do 50 V; 15 A do 20,5 A od 0 W do 1,025 kW CMC 0,95 mW/VA 50 V do 60 V; 150 mA do 200 mA od 0 W do 1,23 kW CMC 0,90 mW/VA 50 V do 60 V; 200 mA do 300 mA od 0 W do 1,23 kW CMC 0,72 mW/VA 50 V do 60 V; 300 mA do 400 mA od 0 W do 1,23 kW CMC 0,90 mW/VA 50 V do 60 V; 400 mA do 600 mA od 0 W do 1,23 kW CMC 0,72 mW/VA 50 V do 60 V; 600 mA do 800 mA od 0 W do 1,23 kW CMC 0,90 mW/VA 50 V do 60 V; 800 mA do 1,3 A od 0 W do 1,23 kW CMC 0,72 mW/VA 50 V do 60 V; 1,3 A do 2 A od 0 W do 1,23 kW CMC 0,85 mW/VA 50 V do 60 V; 2 A do 2,6 A od 0 W do 1,23 kW CMC 0,62 mW/VA 50 V do 60 V; 2,6 A do 4 A od 0 W do 1,23 kW CMC 0,85 mW/VA 50 V do 60 V; 4 A do 5,2 A od 0 W do 1,23 kW CMC 0,62 mW/VA 50 V do 60 V; 5,2 A do 8 A od 0 W do 1,23 kW CMC 0,85 mW/VA 50 V do 60 V; 8 A do 10 A od 0 W do 1,23 kW CMC 0,62 mW/VA 50 V do 60 V; 10 A do 15 A od 0 W do 1,23 kW CMC 0,87 mW/VA 50 V do 60 V; 15 A do 20,5 A od 0 W do 1,23 kW CMC 0,65 mW/VA 60 V do 120 V; 150 mA do 200 mA od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 200 mA do 250 mA od 0 W do 2,46 kW CMC 1,1 mW/VA 60 V do 120 V; 250 mA do 300 mA od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 300 mA do 400 mA od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 400 mA do 500 mA od 0 W do 2,46 kW CMC 1,1 mW/VA 60 V do 120 V; 500 mA do 600 mA od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 600 mA do 800 mA od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 800 mA do 1 A od 0 W do 2,46 kW CMC 1,1 mW/VA 60 V do 120 V; 1 A do 1,3 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 1,3 A do 2 A od 0 W do 2,46 kW CMC 1,3 mW/VA 60 V do 120 V; 2 A do 2,6 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 2,6 A do 4 A od 0 W do 2,46 kW CMC 1,3 mW/VA 60 V do 120 V; 4 A do 5,2 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 5,2 A do 8 A od 0 W do 2,46 kW CMC 1,3 mW/VA 60 V do 120 V; 8 A do 10 A od 0 W do 2,46 kW CMC 0,90 mW/VA 60 V do 120 V; 10 A do 15 A od 0 W do 2,46 kW CMC 1,4 mW/VA 60 V do 120 V; 15 A do 20,5 A od 0 W do 2,46 kW CMC 0,95 mW/VA 120 V do 130 V; 150 mA do 200 mA od 0 W do 2,665 kW CMC 0,80 mW/VA 120 V do 130 V; 200 mA do 300 mA od 0 W do 2,665 kW CMC 0,65 mW/VA 120 V do 130 V; 300 mA do 400 mA od 0 W do 2,665 kW CMC 0,81 mW/VA 120 V do 130 V; 400 mA do 600 mA od 0 W do 2,665 kW CMC 0,65 mW/VA 120 V do 130 V; 600 mA do 800 mA od 0 W do 2,665 kW CMC 0,80 mW/VA 120 V do 130 V; 800 mA do 1 A od 0 W do 2,665 kW CMC 0,65 mW/VA 120 V do 130 V; 1 A do 1,3 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 1,3 A do 2 A od 0 W do 2,665 kW CMC 0,76 mW/VA 120 V do 130 V; 2 A do 2,6 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 2,6 A do 4 A od 0 W do 2,665 kW CMC 0,76 mW/VA 120 V do 130 V; 4 A do 5,2 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 5,2 A do 8 A od 0 W do 2,665 kW CMC 0,76 mW/VA 120 V do 130 V; 8 A do 10 A od 0 W do 2,665 kW CMC 0,56 mW/VA 120 V do 130 V; 10 A do 15 A od 0 W do 2,665 kW CMC 0,78 mW/VA 120 V do 130 V; 15 A do 20,5 A od 0 W do 2,665 kW CMC 0,59 mW/VA 130 V do 230 V; 150 mA do 200 mA od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 200 mA do 250 mA od 0 W do 4,715 kW CMC 1,1 mW/VA 130 V do 230 V; 250 mA do 300 mA od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 300 mA do 400 mA od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 400 mA do 500 mA od 0 W do 4,715 kW CMC 1,1 mW/VA 130 V do 230 V; 500 mA do 600 mA od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 600 mA do 800 mA od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 800 mA do 1 A od 0 W do 4,715 kW CMC 1,1 mW/VA 130 V do 230 V; 1 A do 1,3 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 1,3 A do 2 A od 0 W do 4,715 kW CMC 1,3 mW/VA 130 V do 230 V; 2 A do 2,6 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 2,6 A do 4 A od 0 W do 4,715 kW CMC 1,3 mW/VA 130 V do 230 V; 4 A do 5,2 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 5,2 A do 8 A od 0 W do 4,715 kW CMC 1,3 mW/VA 130 V do 230 V; 8 A do 10 A od 0 W do 4,715 kW CMC 0,90 mW/VA 130 V do 230 V; 10 A do 15 A od 0 W do 4,715 kW CMC 1,4 mW/VA 130 V do 230 V; 15 A do 20,5 A od 0 W do 4,715 kW CMC 0,95 mW/VA 230 V do 270 V; 150 mA do 200 mA od 0 W do 5,535 kW CMC 0,80 mW/VA 230 V do 270 V; 200 mA do 300 mA od 0 W do 5,535 kW CMC 0,65 mW/VA 230 V do 270 V; 300 mA do 400 mA od 0 W do 5,535 kW CMC 0,81 mW/VA 230 V do 270 V; 400 mA do 600 mA od 0 W do 5,535 kW CMC 0,65 mW/VA 230 V do 270 V; 600 mA do 800 mA od 0 W do 5,535 kW CMC 0,80 mW/VA 230 V do 270 V; 800 mA do 1 A od 0 W do 5,535 kW CMC 0,65 mW/VA 230 V do 270 V; 1 A do 1,3 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 1,3 A do 2 A od 0 W do 5,535 kW CMC 0,76 mW/VA 230 V do 270 V; 2 A do 2,6 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 2,6 A do 4 A od 0 W do 5,535 kW CMC 0,76 mW/VA 230 V do 270 V; 4 A do 5,2 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 5,2 A do 8 A od 0 W do 5,535 kW CMC 0,76 mW/VA 230 V do 270 V; 8 A do 10 A od 0 W do 5,535 kW CMC 0,56 mW/VA 230 V do 270 V; 10 A do 15 A od 0 W do 5,535 kW CMC 0,78 mW/VA 230 V do 270 V; 15 A do 20,5 A od 0 W do 5,535 kW CMC 0,59 mW/VA 270 V do 540 V; 150 mA do 200 mA od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 200 mA do 250 mA od 0 W do 11,07 kW CMC 1,1 mW/VA 270 V do 540 V; 250 mA do 300 mA od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 300 mA do 400 mA od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 400 mA do 500 mA od 0 W do 11,07 kW CMC 1,1 mW/VA 270 V do 540 V; 500 mA do 600 mA od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 600 mA do 800 mA od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 800 mA do 1 A od 0 W do 11,07 kW CMC 1,1 mW/VA 270 V do 540 V; 1 A do 1,3 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 1,3 A do 2 A od 0 W do 11,07 kW CMC 1,3 mW/VA 270 V do 540 V; 2 A do 2,6 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 2,6 A do 4 A od 0 W do 11,07 kW CMC 1,3 mW/VA 270 V do 540 V; 4 A do 5,2 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 5,2 A do 8 A od 0 W do 11,07 kW CMC 1,3 mW/VA 270 V do 540 V; 8 A do 10 A od 0 W do 11,07 kW CMC 0,90 mW/VA 270 V do 540 V; 10 A do 15 A od 0 W do 11,07 kW CMC 1,4 mW/VA 270 V do 540 V; 15 A do 20,5 A od 0 W do 11,07 kW CMC 0,95 mW/VA 540 V do 560 V; 150 mA do 200 mA od 0 W do 11,48 kW CMC 0,80 mW/VA 540 V do 560 V; 200 mA do 300 mA od 0 W do 11,48 kW CMC 0,65 mW/VA 540 V do 560 V; 300 mA do 400 mA od 0 W do 11,48 kW CMC 0,81 mW/VA 540 V do 560 V; 400 mA do 600 mA od 0 W do 11,48 kW CMC 0,65 mW/VA 540 V do 560 V; 600 mA do 800 mA od 0 W do 11,48 kW CMC 0,80 mW/VA 540 V do 560 V; 800 mA do 1 A od 0 W do 11,48 kW CMC 0,65 mW/VA 540 V do 560 V; 1 A do 1,3 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 1,3 A do 2 A od 0 W do 11,48 kW CMC 0,76 mW/VA 540 V do 560 V; 2 A do 2,6 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 2,6 A do 4 A od 0 W do 11,48 kW CMC 0,76 mW/VA 540 V do 560 V; 4 A do 5,2 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 5,2 A do 8 A od 0 W do 11,48 kW CMC 0,76 mW/VA 540 V do 560 V; 8 A do 10 A od 0 W do 11,48 kW CMC 0,56 mW/VA 540 V do 560 V; 10 A do 15 A od 0 W do 11,48 kW CMC 0,78 mW/VA 540 V do 560 V; 15 A do 20,5 A od 0 W do 11,48 kW CMC 0,59 mW/VA 560 V do 700 V; 150 mA do 200 mA od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 200 mA do 250 mA od 0 W do 14,35 kW CMC 1,1 mW/VA 560 V do 700 V; 250 mA do 300 mA od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 300 mA do 400 mA od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 400 mA do 500 mA od 0 W do 14,35 kW CMC 1,1 mW/VA 560 V do 700 V; 500 mA do 600 mA od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 600 mA do 800 mA od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 800 mA do 1 A od 0 W do 14,35 kW CMC 1,1 mW/VA 560 V do 700 V; 1 A do 1,3 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 1,3 A do 2 A od 0 W do 14,35 kW CMC 1,3 mW/VA 560 V do 700 V; 2 A do 2,6 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 2,6 A do 4 A od 0 W do 14,35 kW CMC 1,3 mW/VA 560 V do 700 V; 4 A do 5,2 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 5,2 A do 8 A od 0 W do 14,35 kW CMC 1,3 mW/VA 560 V do 700 V; 8 A do 10 A od 0 W do 14,35 kW CMC 0,90 mW/VA 560 V do 700 V; 10 A do 15 A od 0 W do 14,35 kW CMC 1,4 mW/VA 560 V do 700 V; 15 A do 20,5 A od 0 W do 14,35 kW CMC 0,95 mW/VA 700 V do 720 V; 150 mA do 200 mA od 0 W do 14,76 kW CMC 1,1 mW/VA 700 V do 720 V; 200 mA do 250 mA od 0 W do 14,76 kW CMC 0,80 mW/VA 700 V do 720 V; 250 mA do 300 mA od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 300 mA do 400 mA od 0 W do 14,76 kW CMC 1,0 mW/VA 700 V do 720 V; 400 mA do 500 mA od 0 W do 14,76 kW CMC 0,80 mW/VA 700 V do 720 V; 500 mA do 600 mA od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 600 mA do 800 mA od 0 W do 14,76 kW CMC 1,0 mW/VA 700 V do 720 V; 800 mA do 1 A od 0 W do 14,76 kW CMC 0,80 mW/VA 700 V do 720 V; 1 A do 1,3 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 1,3 A do 2 A od 0 W do 14,76 kW CMC 0,94 mW/VA 700 V do 720 V; 2 A do 2,6 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 2,6 A do 4 A od 0 W do 14,76 kW CMC 0,94 mW/VA 700 V do 720 V; 4 A do 5,2 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 5,2 A do 8 A od 0 W do 14,76 kW CMC 0,94 mW/VA 700 V do 720 V; 8 A do 10 A od 0 W do 14,76 kW CMC 0,68 mW/VA 700 V do 720 V; 10 A do 15 A od 0 W do 14,76 kW CMC 0,97 mW/VA 700 V do 720 V; 15 A do 20,5 A od 0 W do 14,76 kW CMC 0,71 mW/VA Stridavy cinny vykon jednofazovy / Zdroje (f: 45 Hz az 65 Hz, PF: 0 az 1) Kalibrace – elektricke veliciny Prime mereni meridlem vykonu 25 V az 30 V; 150 mA az 200 mA 0 W az 615 W CMC 0,90 mW/VA 25 V az 30 V; 200 mA az 300 mA 0 W az 615 W CMC 0,72 mW/VA 25 V az 30 V; 300 mA az 400 mA 0 W az 615 W CMC 0,90 mW/VA 25 V az 30 V; 400 mA az 600 mA 0 W az 615 W CMC 0,72 mW/VA 25 V az 30 V; 600 mA az 800 mA 0 W az 615 W CMC 0,90 mW/VA 25 V az 30 V; 800 mA az 1,3 A 0 W az 615 W CMC 0,72 mW/VA 25 V az 30 V; 1,3 A az 2 A 0 W az 615 W CMC 0,85 mW/VA 25 V az 30 V; 2 A az 2,6 A 0 W az 615 W CMC 0,62 mW/VA 25 V az 30 V; 2,6 A az 4 A 0 W az 615 W CMC 0,85 mW/VA 25 V az 30 V; 4 A az 5,2 A 0 W az 615 W CMC 0,62 mW/VA 25 V az 30 V; 5,2 A az 8 A 0 W az 615 W CMC 0,85 mW/VA 25 V az 30 V; 8 A az 10 A 0 W az 615 W CMC 0,62 mW/VA 25 V az 30 V; 10 A az 15 A 0 W az 615 W CMC 0,87 mW/VA 25 V az 30 V; 15 A az 20,5 A 0 W az 615 W CMC 0,65 mW/VA 30 V az 50 V; 150 mA az 200 mA 0 W az 1,025 kW CMC 1,4 mW/VA 30 V az 50 V; 200 mA az 250 mA 0 W az 1,025 kW CMC 1,1 mW/VA 30 V az 50 V; 250 mA az 300 mA 0 W az 1,025 kW CMC 0,90 mW/VA 30 V az 50 V; 300 mA az 400 mA 0 W az 1,025 kW CMC 1,4 mW/VA 30 V az 50 V; 400 mA az 500 mA 0 W az 1,025 kW CMC 1,1 mW/VA 30 V az 50 V; 500 mA az 600 mA 0 W az 1,025 kW CMC 0,90 mW/VA 30 V az 50 V; 600 mA az 800 mA 0 W az 1,025 kW CMC 1,4 mW/VA 30 V az 50 V; 800 mA az 1 A 0 W az 1,025 kW CMC 1,1 mW/VA 30 V az 50 V; 1 A az 1,3 A 0 W az 1,025 kW CMC 0,90 mW/VA 30 V az 50 V; 1,3 A az 2 A 0 W az 1,025 kW CMC 1,3 mW/VA 30 V az 50 V; 2 A az 2,6 A 0 W az 1,025 kW CMC 0,90 mW/VA 30 V az 50 V; 2,6 A az 4 A 0 W az 1,025 kW CMC 1,3 mW/VA 30 V az 50 V; 4 A az 5,2 A 0 W az 1,025 kW CMC 0,90 mW/VA 30 V az 50 V; 5,2 A az 8 A 0 W az 1,025 kW CMC 1,3 mW/VA 30 V az 50 V; 8 A az 10 A 0 W az 1,025 kW CMC 0,90 mW/VA 30 V az 50 V; 10 A az 15 A 0 W az 1,025 kW CMC 1,4 mW/VA 30 V az 50 V; 15 A az 20,5 A 0 W az 1,025 kW CMC 0,95 mW/VA 50 V az 60 V; 150 mA az 200 mA 0 W az 1,23 kW CMC 0,90 mW/VA 50 V az 60 V; 200 mA az 300 mA 0 W az 1,23 kW CMC 0,72 mW/VA 50 V az 60 V; 300 mA az 400 mA 0 W az 1,23 kW CMC 0,90 mW/VA 50 V az 60 V; 400 mA az 600 mA 0 W az 1,23 kW CMC 0,72 mW/VA 50 V az 60 V; 600 mA az 800 mA 0 W az 1,23 kW CMC 0,90 mW/VA 50 V az 60 V; 800 mA az 1,3 A 0 W az 1,23 kW CMC 0,72 mW/VA 50 V az 60 V; 1,3 A az 2 A 0 W az 1,23 kW CMC 0,85 mW/VA 50 V az 60 V; 2 A az 2,6 A 0 W az 1,23 kW CMC 0,62 mW/VA 50 V az 60 V; 2,6 A az 4 A 0 W az 1,23 kW CMC 0,85 mW/VA 50 V az 60 V; 4 A az 5,2 A 0 W az 1,23 kW CMC 0,62 mW/VA 50 V az 60 V; 5,2 A az 8 A 0 W az 1,23 kW CMC 0,85 mW/VA 50 V az 60 V; 8 A az 10 A 0 W az 1,23 kW CMC 0,62 mW/VA 50 V az 60 V; 10 A az 15 A 0 W az 1,23 kW CMC 0,87 mW/VA 50 V az 60 V; 15 A az 20,5 A 0 W az 1,23 kW CMC 0,65 mW/VA 60 V az 120 V; 150 mA az 200 mA 0 W az 2,46 kW CMC 1,4 mW/VA 60 V az 120 V; 200 mA az 250 mA 0 W az 2,46 kW CMC 1,1 mW/VA 60 V az 120 V; 250 mA az 300 mA 0 W az 2,46 kW CMC 0,90 mW/VA 60 V az 120 V; 300 mA az 400 mA 0 W az 2,46 kW CMC 1,4 mW/VA 60 V az 120 V; 400 mA az 500 mA 0 W az 2,46 kW CMC 1,1 mW/VA 60 V az 120 V; 500 mA az 600 mA 0 W az 2,46 kW CMC 0,90 mW/VA 60 V az 120 V; 600 mA az 800 mA 0 W az 2,46 kW CMC 1,4 mW/VA 60 V az 120 V; 800 mA az 1 A 0 W az 2,46 kW CMC 1,1 mW/VA 60 V az 120 V; 1 A az 1,3 A 0 W az 2,46 kW CMC 0,90 mW/VA 60 V az 120 V; 1,3 A az 2 A 0 W az 2,46 kW CMC 1,3 mW/VA 60 V az 120 V; 2 A az 2,6 A 0 W az 2,46 kW CMC 0,90 mW/VA 60 V az 120 V; 2,6 A az 4 A 0 W az 2,46 kW CMC 1,3 mW/VA 60 V az 120 V; 4 A az 5,2 A 0 W az 2,46 kW CMC 0,90 mW/VA 60 V az 120 V; 5,2 A az 8 A 0 W az 2,46 kW CMC 1,3 mW/VA 60 V az 120 V; 8 A az 10 A 0 W az 2,46 kW CMC 0,90 mW/VA 60 V az 120 V; 10 A az 15 A 0 W az 2,46 kW CMC 1,4 mW/VA 60 V az 120 V; 15 A az 20,5 A 0 W az 2,46 kW CMC 0,95 mW/VA 120 V az 130 V; 150 mA az 200 mA 0 W az 2,665 kW CMC 0,80 mW/VA 120 V az 130 V; 200 mA az 300 mA 0 W az 2,665 kW CMC 0,65 mW/VA 120 V az 130 V; 300 mA az 400 mA 0 W az 2,665 kW CMC 0,81 mW/VA 120 V az 130 V; 400 mA az 600 mA 0 W az 2,665 kW CMC 0,65 mW/VA 120 V az 130 V; 600 mA az 800 mA 0 W az 2,665 kW CMC 0,80 mW/VA 120 V az 130 V; 800 mA az 1 A 0 W az 2,665 kW CMC 0,65 mW/VA 120 V az 130 V; 1 A az 1,3 A 0 W az 2,665 kW CMC 0,56 mW/VA 120 V az 130 V; 1,3 A az 2 A 0 W az 2,665 kW CMC 0,76 mW/VA 120 V az 130 V; 2 A az 2,6 A 0 W az 2,665 kW CMC 0,56 mW/VA 120 V az 130 V; 2,6 A az 4 A 0 W az 2,665 kW CMC 0,76 mW/VA 120 V az 130 V; 4 A az 5,2 A 0 W az 2,665 kW CMC 0,56 mW/VA 120 V az 130 V; 5,2 A az 8 A 0 W az 2,665 kW CMC 0,76 mW/VA 120 V az 130 V; 8 A az 10 A 0 W az 2,665 kW CMC 0,56 mW/VA 120 V az 130 V; 10 A az 15 A 0 W az 2,665 kW CMC 0,78 mW/VA 120 V az 130 V; 15 A az 20,5 A 0 W az 2,665 kW CMC 0,59 mW/VA 130 V az 230 V; 150 mA az 200 mA 0 W az 4,715 kW CMC 1,4 mW/VA 130 V az 230 V; 200 mA az 250 mA 0 W az 4,715 kW CMC 1,1 mW/VA 130 V az 230 V; 250 mA az 300 mA 0 W az 4,715 kW CMC 0,90 mW/VA 130 V az 230 V; 300 mA az 400 mA 0 W az 4,715 kW CMC 1,4 mW/VA 130 V az 230 V; 400 mA az 500 mA 0 W az 4,715 kW CMC 1,1 mW/VA 130 V az 230 V; 500 mA az 600 mA 0 W az 4,715 kW CMC 0,90 mW/VA 130 V az 230 V; 600 mA az 800 mA 0 W az 4,715 kW CMC 1,4 mW/VA 130 V az 230 V; 800 mA az 1 A 0 W az 4,715 kW CMC 1,1 mW/VA 130 V az 230 V; 1 A az 1,3 A 0 W az 4,715 kW CMC 0,90 mW/VA 130 V az 230 V; 1,3 A az 2 A 0 W az 4,715 kW CMC 1,3 mW/VA 130 V az 230 V; 2 A az 2,6 A 0 W az 4,715 kW CMC 0,90 mW/VA 130 V az 230 V; 2,6 A az 4 A 0 W az 4,715 kW CMC 1,3 mW/VA 130 V az 230 V; 4 A az 5,2 A 0 W az 4,715 kW CMC 0,90 mW/VA 130 V az 230 V; 5,2 A az 8 A 0 W az 4,715 kW CMC 1,3 mW/VA 130 V az 230 V; 8 A az 10 A 0 W az 4,715 kW CMC 0,90 mW/VA 130 V az 230 V; 10 A az 15 A 0 W az 4,715 kW CMC 1,4 mW/VA 130 V az 230 V; 15 A az 20,5 A 0 W az 4,715 kW CMC 0,95 mW/VA 230 V az 270 V; 150 mA az 200 mA 0 W az 5,535 kW CMC 0,80 mW/VA 230 V az 270 V; 200 mA az 300 mA 0 W az 5,535 kW CMC 0,65 mW/VA 230 V az 270 V; 300 mA az 400 mA 0 W az 5,535 kW CMC 0,81 mW/VA 230 V az 270 V; 400 mA az 600 mA 0 W az 5,535 kW CMC 0,65 mW/VA 230 V az 270 V; 600 mA az 800 mA 0 W az 5,535 kW CMC 0,80 mW/VA 230 V az 270 V; 800 mA az 1 A 0 W az 5,535 kW CMC 0,65 mW/VA 230 V az 270 V; 1 A az 1,3 A 0 W az 5,535 kW CMC 0,56 mW/VA 230 V az 270 V; 1,3 A az 2 A 0 W az 5,535 kW CMC 0,76 mW/VA 230 V az 270 V; 2 A az 2,6 A 0 W az 5,535 kW CMC 0,56 mW/VA 230 V az 270 V; 2,6 A az 4 A 0 W az 5,535 kW CMC 0,76 mW/VA 230 V az 270 V; 4 A az 5,2 A 0 W az 5,535 kW CMC 0,56 mW/VA 230 V az 270 V; 5,2 A az 8 A 0 W az 5,535 kW CMC 0,76 mW/VA 230 V az 270 V; 8 A az 10 A 0 W az 5,535 kW CMC 0,56 mW/VA 230 V az 270 V; 10 A az 15 A 0 W az 5,535 kW CMC 0,78 mW/VA 230 V az 270 V; 15 A az 20,5 A 0 W az 5,535 kW CMC 0,59 mW/VA 270 V az 540 V; 150 mA az 200 mA 0 W az 11,07 kW CMC 1,4 mW/VA 270 V az 540 V; 200 mA az 250 mA 0 W az 11,07 kW CMC 1,1 mW/VA 270 V az 540 V; 250 mA az 300 mA 0 W az 11,07 kW CMC 0,90 mW/VA 270 V az 540 V; 300 mA az 400 mA 0 W az 11,07 kW CMC 1,4 mW/VA 270 V az 540 V; 400 mA az 500 mA 0 W az 11,07 kW CMC 1,1 mW/VA 270 V az 540 V; 500 mA az 600 mA 0 W az 11,07 kW CMC 0,90 mW/VA 270 V az 540 V; 600 mA az 800 mA 0 W az 11,07 kW CMC 1,4 mW/VA 270 V az 540 V; 800 mA az 1 A 0 W az 11,07 kW CMC 1,1 mW/VA 270 V az 540 V; 1 A az 1,3 A 0 W az 11,07 kW CMC 0,90 mW/VA 270 V az 540 V; 1,3 A az 2 A 0 W az 11,07 kW CMC 1,3 mW/VA 270 V az 540 V; 2 A az 2,6 A 0 W az 11,07 kW CMC 0,90 mW/VA 270 V az 540 V; 2,6 A az 4 A 0 W az 11,07 kW CMC 1,3 mW/VA 270 V az 540 V; 4 A az 5,2 A 0 W az 11,07 kW CMC 0,90 mW/VA 270 V az 540 V; 5,2 A az 8 A 0 W az 11,07 kW CMC 1,3 mW/VA 270 V az 540 V; 8 A az 10 A 0 W az 11,07 kW CMC 0,90 mW/VA 270 V az 540 V; 10 A az 15 A 0 W az 11,07 kW CMC 1,4 mW/VA 270 V az 540 V; 15 A az 20,5 A 0 W az 11,07 kW CMC 0,95 mW/VA 540 V az 560 V; 150 mA az 200 mA 0 W az 11,48 kW CMC 0,80 mW/VA 540 V az 560 V; 200 mA az 300 mA 0 W az 11,48 kW CMC 0,65 mW/VA 540 V az 560 V; 300 mA az 400 mA 0 W az 11,48 kW CMC 0,81 mW/VA 540 V az 560 V; 400 mA az 600 mA 0 W az 11,48 kW CMC 0,65 mW/VA 540 V az 560 V; 600 mA az 800 mA 0 W az 11,48 kW CMC 0,80 mW/VA 540 V az 560 V; 800 mA az 1 A 0 W az 11,48 kW CMC 0,65 mW/VA 540 V az 560 V; 1 A az 1,3 A 0 W az 11,48 kW CMC 0,56 mW/VA 540 V az 560 V; 1,3 A az 2 A 0 W az 11,48 kW CMC 0,76 mW/VA 540 V az 560 V; 2 A az 2,6 A 0 W az 11,48 kW CMC 0,56 mW/VA 540 V az 560 V; 2,6 A az 4 A 0 W az 11,48 kW CMC 0,76 mW/VA 540 V az 560 V; 4 A az 5,2 A 0 W az 11,48 kW CMC 0,56 mW/VA 540 V az 560 V; 5,2 A az 8 A 0 W az 11,48 kW CMC 0,76 mW/VA 540 V az 560 V; 8 A az 10 A 0 W az 11,48 kW CMC 0,56 mW/VA 540 V az 560 V; 10 A az 15 A 0 W az 11,48 kW CMC 0,78 mW/VA 540 V az 560 V; 15 A az 20,5 A 0 W az 11,48 kW CMC 0,59 mW/VA 560 V az 700 V; 150 mA az 200 mA 0 W az 14,35 kW CMC 1,4 mW/VA 560 V az 700 V; 200 mA az 250 mA 0 W az 14,35 kW CMC 1,1 mW/VA 560 V az 700 V; 250 mA az 300 mA 0 W az 14,35 kW CMC 0,90 mW/VA 560 V az 700 V; 300 mA az 400 mA 0 W az 14,35 kW CMC 1,4 mW/VA 560 V az 700 V; 400 mA az 500 mA 0 W az 14,35 kW CMC 1,1 mW/VA 560 V az 700 V; 500 mA az 600 mA 0 W az 14,35 kW CMC 0,90 mW/VA 560 V az 700 V; 600 mA az 800 mA 0 W az 14,35 kW CMC 1,4 mW/VA 560 V az 700 V; 800 mA az 1 A 0 W az 14,35 kW CMC 1,1 mW/VA 560 V az 700 V; 1 A az 1,3 A 0 W az 14,35 kW CMC 0,90 mW/VA 560 V az 700 V; 1,3 A az 2 A 0 W az 14,35 kW CMC 1,3 mW/VA 560 V az 700 V; 2 A az 2,6 A 0 W az 14,35 kW CMC 0,90 mW/VA 560 V az 700 V; 2,6 A az 4 A 0 W az 14,35 kW CMC 1,3 mW/VA 560 V az 700 V; 4 A az 5,2 A 0 W az 14,35 kW CMC 0,90 mW/VA 560 V az 700 V; 5,2 A az 8 A 0 W az 14,35 kW CMC 1,3 mW/VA 560 V az 700 V; 8 A az 10 A 0 W az 14,35 kW CMC 0,90 mW/VA 560 V az 700 V; 10 A az 15 A 0 W az 14,35 kW CMC 1,4 mW/VA 560 V az 700 V; 15 A az 20,5 A 0 W az 14,35 kW CMC 0,95 mW/VA 700 V az 720 V; 150 mA az 200 mA 0 W az 14,76 kW CMC 1,1 mW/VA 700 V az 720 V; 200 mA az 250 mA 0 W az 14,76 kW CMC 0,80 mW/VA 700 V az 720 V; 250 mA az 300 mA 0 W az 14,76 kW CMC 0,68 mW/VA 700 V az 720 V; 300 mA az 400 mA 0 W az 14,76 kW CMC 1,0 mW/VA 700 V az 720 V; 400 mA az 500 mA 0 W az 14,76 kW CMC 0,80 mW/VA 700 V az 720 V; 500 mA az 600 mA 0 W az 14,76 kW CMC 0,68 mW/VA 700 V az 720 V; 600 mA az 800 mA 0 W az 14,76 kW CMC 1,0 mW/VA 700 V az 720 V; 800 mA az 1 A 0 W az 14,76 kW CMC 0,80 mW/VA 700 V az 720 V; 1 A az 1,3 A 0 W az 14,76 kW CMC 0,68 mW/VA 700 V az 720 V; 1,3 A az 2 A 0 W az 14,76 kW CMC 0,94 mW/VA 700 V az 720 V; 2 A az 2,6 A 0 W az 14,76 kW CMC 0,68 mW/VA 700 V az 720 V; 2,6 A az 4 A 0 W az 14,76 kW CMC 0,94 mW/VA 700 V az 720 V; 4 A az 5,2 A 0 W az 14,76 kW CMC 0,68 mW/VA 700 V az 720 V; 5,2 A az 8 A 0 W az 14,76 kW CMC 0,94 mW/VA 700 V az 720 V; 8 A az 10 A 0 W az 14,76 kW CMC 0,68 mW/VA 700 V az 720 V; 10 A az 15 A 0 W az 14,76 kW CMC 0,97 mW/VA 700 V az 720 V; 15 A az 20,5 A 0 W az 14,76 kW CMC 0,71 mW/VA TP16","search_en":"AC active power, single phase / Sources (f: 45 Hz to 65 Hz, PF: 0 to 1) Calibration – electrical quantities Direct measurement by a power meter 25 V to 30 V; 150 mA to 200 mA 0 W to 615 W CMC 0,90 mW/VA 25 V to 30 V; 200 mA to 300 mA 0 W to 615 W CMC 0,72 mW/VA 25 V to 30 V; 300 mA to 400 mA 0 W to 615 W CMC 0,90 mW/VA 25 V to 30 V; 400 mA to 600 mA 0 W to 615 W CMC 0,72 mW/VA 25 V to 30 V; 600 mA to 800 mA 0 W to 615 W CMC 0,90 mW/VA 25 V to 30 V; 800 mA to 1,3 A 0 W to 615 W CMC 0,72 mW/VA 25 V to 30 V; 1,3 A to 2 A 0 W to 615 W CMC 0,85 mW/VA 25 V to 30 V; 2 A to 2,6 A 0 W to 615 W CMC 0,62 mW/VA 25 V to 30 V; 2,6 A to 4 A 0 W to 615 W CMC 0,85 mW/VA 25 V to 30 V; 4 A to 5,2 A 0 W to 615 W CMC 0,62 mW/VA 25 V to 30 V; 5,2 A to 8 A 0 W to 615 W CMC 0,85 mW/VA 25 V to 30 V; 8 A to 10 A 0 W to 615 W CMC 0,62 mW/VA 25 V to 30 V; 10 A to 15 A 0 W to 615 W CMC 0,87 mW/VA 25 V to 30 V; 15 A to 20,5 A 0 W to 615 W CMC 0,65 mW/VA 30 V to 50 V; 150 mA to 200 mA 0 W to 1,025 kW CMC 1,4 mW/VA 30 V to 50 V; 200 mA to 250 mA 0 W to 1,025 kW CMC 1,1 mW/VA 30 V to 50 V; 250 mA to 300 mA 0 W to 1,025 kW CMC 0,90 mW/VA 30 V to 50 V; 300 mA to 400 mA 0 W to 1,025 kW CMC 1,4 mW/VA 30 V to 50 V; 400 mA to 500 mA 0 W to 1,025 kW CMC 1,1 mW/VA 30 V to 50 V; 500 mA to 600 mA 0 W to 1,025 kW CMC 0,90 mW/VA 30 V to 50 V; 600 mA to 800 mA 0 W to 1,025 kW CMC 1,4 mW/VA 30 V to 50 V; 800 mA to 1 A 0 W to 1,025 kW CMC 1,1 mW/VA 30 V to 50 V; 1 A to 1,3 A 0 W to 1,025 kW CMC 0,90 mW/VA 30 V to 50 V; 1,3 A to 2 A 0 W to 1,025 kW CMC 1,3 mW/VA 30 V to 50 V; 2 A to 2,6 A 0 W to 1,025 kW CMC 0,90 mW/VA 30 V to 50 V; 2,6 A to 4 A 0 W to 1,025 kW CMC 1,3 mW/VA 30 V to 50 V; 4 A to 5,2 A 0 W to 1,025 kW CMC 0,90 mW/VA 30 V to 50 V; 5,2 A to 8 A 0 W to 1,025 kW CMC 1,3 mW/VA 30 V to 50 V; 8 A to 10 A 0 W to 1,025 kW CMC 0,90 mW/VA 30 V to 50 V; 10 A to 15 A 0 W to 1,025 kW CMC 1,4 mW/VA 30 V to 50 V; 15 A to 20,5 A 0 W to 1,025 kW CMC 0,95 mW/VA 50 V to 60 V; 150 mA to 200 mA 0 W to 1,23 kW CMC 0,90 mW/VA 50 V to 60 V; 200 mA to 300 mA 0 W to 1,23 kW CMC 0,72 mW/VA 50 V to 60 V; 300 mA to 400 mA 0 W to 1,23 kW CMC 0,90 mW/VA 50 V to 60 V; 400 mA to 600 mA 0 W to 1,23 kW CMC 0,72 mW/VA 50 V to 60 V; 600 mA to 800 mA 0 W to 1,23 kW CMC 0,90 mW/VA 50 V to 60 V; 800 mA to 1,3 A 0 W to 1,23 kW CMC 0,72 mW/VA 50 V to 60 V; 1,3 A to 2 A 0 W to 1,23 kW CMC 0,85 mW/VA 50 V to 60 V; 2 A to 2,6 A 0 W to 1,23 kW CMC 0,62 mW/VA 50 V to 60 V; 2,6 A to 4 A 0 W to 1,23 kW CMC 0,85 mW/VA 50 V to 60 V; 4 A to 5,2 A 0 W to 1,23 kW CMC 0,62 mW/VA 50 V to 60 V; 5,2 A to 8 A 0 W to 1,23 kW CMC 0,85 mW/VA 50 V to 60 V; 8 A to 10 A 0 W to 1,23 kW CMC 0,62 mW/VA 50 V to 60 V; 10 A to 15 A 0 W to 1,23 kW CMC 0,87 mW/VA 50 V to 60 V; 15 A to 20,5 A 0 W to 1,23 kW CMC 0,65 mW/VA 60 V to 120 V; 150 mA to 200 mA 0 W to 2,46 kW CMC 1,4 mW/VA 60 V to 120 V; 200 mA to 250 mA 0 W to 2,46 kW CMC 1,1 mW/VA 60 V to 120 V; 250 mA to 300 mA 0 W to 2,46 kW CMC 0,90 mW/VA 60 V to 120 V; 300 mA to 400 mA 0 W to 2,46 kW CMC 1,4 mW/VA 60 V to 120 V; 400 mA to 500 mA 0 W to 2,46 kW CMC 1,1 mW/VA 60 V to 120 V; 500 mA to 600 mA 0 W to 2,46 kW CMC 0,90 mW/VA 60 V to 120 V; 600 mA to 800 mA 0 W to 2,46 kW CMC 1,4 mW/VA 60 V to 120 V; 800 mA to 1 A 0 W to 2,46 kW CMC 1,1 mW/VA 60 V to 120 V; 1 A to 1,3 A 0 W to 2,46 kW CMC 0,90 mW/VA 60 V to 120 V; 1,3 A to 2 A 0 W to 2,46 kW CMC 1,3 mW/VA 60 V to 120 V; 2 A to 2,6 A 0 W to 2,46 kW CMC 0,90 mW/VA 60 V to 120 V; 2,6 A to 4 A 0 W to 2,46 kW CMC 1,3 mW/VA 60 V to 120 V; 4 A to 5,2 A 0 W to 2,46 kW CMC 0,90 mW/VA 60 V to 120 V; 5,2 A to 8 A 0 W to 2,46 kW CMC 1,3 mW/VA 60 V to 120 V; 8 A to 10 A 0 W to 2,46 kW CMC 0,90 mW/VA 60 V to 120 V; 10 A to 15 A 0 W to 2,46 kW CMC 1,4 mW/VA 60 V to 120 V; 15 A to 20,5 A 0 W to 2,46 kW CMC 0,95 mW/VA 120 V to 130 V; 150 mA to 200 mA 0 W to 2,665 kW CMC 0,80 mW/VA 120 V to 130 V; 200 mA to 300 mA 0 W to 2,665 kW CMC 0,65 mW/VA 120 V to 130 V; 300 mA to 400 mA 0 W to 2,665 kW CMC 0,81 mW/VA 120 V to 130 V; 400 mA to 600 mA 0 W to 2,665 kW CMC 0,65 mW/VA 120 V to 130 V; 600 mA to 800 mA 0 W to 2,665 kW CMC 0,80 mW/VA 120 V to 130 V; 800 mA to 1 A 0 W to 2,665 kW CMC 0,65 mW/VA 120 V to 130 V; 1 A to 1,3 A 0 W to 2,665 kW CMC 0,56 mW/VA 120 V to 130 V; 1,3 A to 2 A 0 W to 2,665 kW CMC 0,76 mW/VA 120 V to 130 V; 2 A to 2,6 A 0 W to 2,665 kW CMC 0,56 mW/VA 120 V to 130 V; 2,6 A to 4 A 0 W to 2,665 kW CMC 0,76 mW/VA 120 V to 130 V; 4 A to 5,2 A 0 W to 2,665 kW CMC 0,56 mW/VA 120 V to 130 V; 5,2 A to 8 A 0 W to 2,665 kW CMC 0,76 mW/VA 120 V to 130 V; 8 A to 10 A 0 W to 2,665 kW CMC 0,56 mW/VA 120 V to 130 V; 10 A to 15 A 0 W to 2,665 kW CMC 0,78 mW/VA 120 V to 130 V; 15 A to 20,5 A 0 W to 2,665 kW CMC 0,59 mW/VA 130 V to 230 V; 150 mA to 200 mA 0 W to 4,715 kW CMC 1,4 mW/VA 130 V to 230 V; 200 mA to 250 mA 0 W to 4,715 kW CMC 1,1 mW/VA 130 V to 230 V; 250 mA to 300 mA 0 W to 4,715 kW CMC 0,90 mW/VA 130 V to 230 V; 300 mA to 400 mA 0 W to 4,715 kW CMC 1,4 mW/VA 130 V to 230 V; 400 mA to 500 mA 0 W to 4,715 kW CMC 1,1 mW/VA 130 V to 230 V; 500 mA to 600 mA 0 W to 4,715 kW CMC 0,90 mW/VA 130 V to 230 V; 600 mA to 800 mA 0 W to 4,715 kW CMC 1,4 mW/VA 130 V to 230 V; 800 mA to 1 A 0 W to 4,715 kW CMC 1,1 mW/VA 130 V to 230 V; 1 A to 1,3 A 0 W to 4,715 kW CMC 0,90 mW/VA 130 V to 230 V; 1,3 A to 2 A 0 W to 4,715 kW CMC 1,3 mW/VA 130 V to 230 V; 2 A to 2,6 A 0 W to 4,715 kW CMC 0,90 mW/VA 130 V to 230 V; 2,6 A to 4 A 0 W to 4,715 kW CMC 1,3 mW/VA 130 V to 230 V; 4 A to 5,2 A 0 W to 4,715 kW CMC 0,90 mW/VA 130 V to 230 V; 5,2 A to 8 A 0 W to 4,715 kW CMC 1,3 mW/VA 130 V to 230 V; 8 A to 10 A 0 W to 4,715 kW CMC 0,90 mW/VA 130 V to 230 V; 10 A to 15 A 0 W to 4,715 kW CMC 1,4 mW/VA 130 V to 230 V; 15 A to 20,5 A 0 W to 4,715 kW CMC 0,95 mW/VA 230 V to 270 V; 150 mA to 200 mA 0 W to 5,535 kW CMC 0,80 mW/VA 230 V to 270 V; 200 mA to 300 mA 0 W to 5,535 kW CMC 0,65 mW/VA 230 V to 270 V; 300 mA to 400 mA 0 W to 5,535 kW CMC 0,81 mW/VA 230 V to 270 V; 400 mA to 600 mA 0 W to 5,535 kW CMC 0,65 mW/VA 230 V to 270 V; 600 mA to 800 mA 0 W to 5,535 kW CMC 0,80 mW/VA 230 V to 270 V; 800 mA to 1 A 0 W to 5,535 kW CMC 0,65 mW/VA 230 V to 270 V; 1 A to 1,3 A 0 W to 5,535 kW CMC 0,56 mW/VA 230 V to 270 V; 1,3 A to 2 A 0 W to 5,535 kW CMC 0,76 mW/VA 230 V to 270 V; 2 A to 2,6 A 0 W to 5,535 kW CMC 0,56 mW/VA 230 V to 270 V; 2,6 A to 4 A 0 W to 5,535 kW CMC 0,76 mW/VA 230 V to 270 V; 4 A to 5,2 A 0 W to 5,535 kW CMC 0,56 mW/VA 230 V to 270 V; 5,2 A to 8 A 0 W to 5,535 kW CMC 0,76 mW/VA 230 V to 270 V; 8 A to 10 A 0 W to 5,535 kW CMC 0,56 mW/VA 230 V to 270 V; 10 A to 15 A 0 W to 5,535 kW CMC 0,78 mW/VA 230 V to 270 V; 15 A to 20,5 A 0 W to 5,535 kW CMC 0,59 mW/VA 270 V to 540 V; 150 mA to 200 mA 0 W to 11,07 kW CMC 1,4 mW/VA 270 V to 540 V; 200 mA to 250 mA 0 W to 11,07 kW CMC 1,1 mW/VA 270 V to 540 V; 250 mA to 300 mA 0 W to 11,07 kW CMC 0,90 mW/VA 270 V to 540 V; 300 mA to 400 mA 0 W to 11,07 kW CMC 1,4 mW/VA 270 V to 540 V; 400 mA to 500 mA 0 W to 11,07 kW CMC 1,1 mW/VA 270 V to 540 V; 500 mA to 600 mA 0 W to 11,07 kW CMC 0,90 mW/VA 270 V to 540 V; 600 mA to 800 mA 0 W to 11,07 kW CMC 1,4 mW/VA 270 V to 540 V; 800 mA to 1 A 0 W to 11,07 kW CMC 1,1 mW/VA 270 V to 540 V; 1 A to 1,3 A 0 W to 11,07 kW CMC 0,90 mW/VA 270 V to 540 V; 1,3 A to 2 A 0 W to 11,07 kW CMC 1,3 mW/VA 270 V to 540 V; 2 A to 2,6 A 0 W to 11,07 kW CMC 0,90 mW/VA 270 V to 540 V; 2,6 A to 4 A 0 W to 11,07 kW CMC 1,3 mW/VA 270 V to 540 V; 4 A to 5,2 A 0 W to 11,07 kW CMC 0,90 mW/VA 270 V to 540 V; 5,2 A to 8 A 0 W to 11,07 kW CMC 1,3 mW/VA 270 V to 540 V; 8 A to 10 A 0 W to 11,07 kW CMC 0,90 mW/VA 270 V to 540 V; 10 A to 15 A 0 W to 11,07 kW CMC 1,4 mW/VA 270 V to 540 V; 15 A to 20,5 A 0 W to 11,07 kW CMC 0,95 mW/VA 540 V to 560 V; 150 mA to 200 mA 0 W to 11,48 kW CMC 0,80 mW/VA 540 V to 560 V; 200 mA to 300 mA 0 W to 11,48 kW CMC 0,65 mW/VA 540 V to 560 V; 300 mA to 400 mA 0 W to 11,48 kW CMC 0,81 mW/VA 540 V to 560 V; 400 mA to 600 mA 0 W to 11,48 kW CMC 0,65 mW/VA 540 V to 560 V; 600 mA to 800 mA 0 W to 11,48 kW CMC 0,80 mW/VA 540 V to 560 V; 800 mA to 1 A 0 W to 11,48 kW CMC 0,65 mW/VA 540 V to 560 V; 1 A to 1,3 A 0 W to 11,48 kW CMC 0,56 mW/VA 540 V to 560 V; 1,3 A to 2 A 0 W to 11,48 kW CMC 0,76 mW/VA 540 V to 560 V; 2 A to 2,6 A 0 W to 11,48 kW CMC 0,56 mW/VA 540 V to 560 V; 2,6 A to 4 A 0 W to 11,48 kW CMC 0,76 mW/VA 540 V to 560 V; 4 A to 5,2 A 0 W to 11,48 kW CMC 0,56 mW/VA 540 V to 560 V; 5,2 A to 8 A 0 W to 11,48 kW CMC 0,76 mW/VA 540 V to 560 V; 8 A to 10 A 0 W to 11,48 kW CMC 0,56 mW/VA 540 V to 560 V; 10 A to 15 A 0 W to 11,48 kW CMC 0,78 mW/VA 540 V to 560 V; 15 A to 20,5 A 0 W to 11,48 kW CMC 0,59 mW/VA 560 V to 700 V; 150 mA to 200 mA 0 W to 14,35 kW CMC 1,4 mW/VA 560 V to 700 V; 200 mA to 250 mA 0 W to 14,35 kW CMC 1,1 mW/VA 560 V to 700 V; 250 mA to 300 mA 0 W to 14,35 kW CMC 0,90 mW/VA 560 V to 700 V; 300 mA to 400 mA 0 W to 14,35 kW CMC 1,4 mW/VA 560 V to 700 V; 400 mA to 500 mA 0 W to 14,35 kW CMC 1,1 mW/VA 560 V to 700 V; 500 mA to 600 mA 0 W to 14,35 kW CMC 0,90 mW/VA 560 V to 700 V; 600 mA to 800 mA 0 W to 14,35 kW CMC 1,4 mW/VA 560 V to 700 V; 800 mA to 1 A 0 W to 14,35 kW CMC 1,1 mW/VA 560 V to 700 V; 1 A to 1,3 A 0 W to 14,35 kW CMC 0,90 mW/VA 560 V to 700 V; 1,3 A to 2 A 0 W to 14,35 kW CMC 1,3 mW/VA 560 V to 700 V; 2 A to 2,6 A 0 W to 14,35 kW CMC 0,90 mW/VA 560 V to 700 V; 2,6 A to 4 A 0 W to 14,35 kW CMC 1,3 mW/VA 560 V to 700 V; 4 A to 5,2 A 0 W to 14,35 kW CMC 0,90 mW/VA 560 V to 700 V; 5,2 A to 8 A 0 W to 14,35 kW CMC 1,3 mW/VA 560 V to 700 V; 8 A to 10 A 0 W to 14,35 kW CMC 0,90 mW/VA 560 V to 700 V; 10 A to 15 A 0 W to 14,35 kW CMC 1,4 mW/VA 560 V to 700 V; 15 A to 20,5 A 0 W to 14,35 kW CMC 0,95 mW/VA 700 V to 720 V; 150 mA to 200 mA 0 W to 14,76 kW CMC 1,1 mW/VA 700 V to 720 V; 200 mA to 250 mA 0 W to 14,76 kW CMC 0,80 mW/VA 700 V to 720 V; 250 mA to 300 mA 0 W to 14,76 kW CMC 0,68 mW/VA 700 V to 720 V; 300 mA to 400 mA 0 W to 14,76 kW CMC 1,0 mW/VA 700 V to 720 V; 400 mA to 500 mA 0 W to 14,76 kW CMC 0,80 mW/VA 700 V to 720 V; 500 mA to 600 mA 0 W to 14,76 kW CMC 0,68 mW/VA 700 V to 720 V; 600 mA to 800 mA 0 W to 14,76 kW CMC 1,0 mW/VA 700 V to 720 V; 800 mA to 1 A 0 W to 14,76 kW CMC 0,80 mW/VA 700 V to 720 V; 1 A to 1,3 A 0 W to 14,76 kW CMC 0,68 mW/VA 700 V to 720 V; 1,3 A to 2 A 0 W to 14,76 kW CMC 0,94 mW/VA 700 V to 720 V; 2 A to 2,6 A 0 W to 14,76 kW CMC 0,68 mW/VA 700 V to 720 V; 2,6 A to 4 A 0 W to 14,76 kW CMC 0,94 mW/VA 700 V to 720 V; 4 A to 5,2 A 0 W to 14,76 kW CMC 0,68 mW/VA 700 V to 720 V; 5,2 A to 8 A 0 W to 14,76 kW CMC 0,94 mW/VA 700 V to 720 V; 8 A to 10 A 0 W to 14,76 kW CMC 0,68 mW/VA 700 V to 720 V; 10 A to 15 A 0 W to 14,76 kW CMC 0,97 mW/VA 700 V to 720 V; 15 A to 20,5 A 0 W to 14,76 kW CMC 0,71 mW/VA TP16","search_zh":"单相交流有功功率 / 源（f：45 Hz 至 65 Hz，PF：0 至 1） 校准 – 电学量 用功率计直接测量 25 V 至 30 V；150 mA 至 200 mA 0 W 至 615 W CMC 0,90 mW/VA 25 V 至 30 V；200 mA 至 300 mA 0 W 至 615 W CMC 0,72 mW/VA 25 V 至 30 V；300 mA 至 400 mA 0 W 至 615 W CMC 0,90 mW/VA 25 V 至 30 V；400 mA 至 600 mA 0 W 至 615 W CMC 0,72 mW/VA 25 V 至 30 V；600 mA 至 800 mA 0 W 至 615 W CMC 0,90 mW/VA 25 V 至 30 V；800 mA 至 1,3 A 0 W 至 615 W CMC 0,72 mW/VA 25 V 至 30 V；1,3 A 至 2 A 0 W 至 615 W CMC 0,85 mW/VA 25 V 至 30 V；2 A 至 2,6 A 0 W 至 615 W CMC 0,62 mW/VA 25 V 至 30 V；2,6 A 至 4 A 0 W 至 615 W CMC 0,85 mW/VA 25 V 至 30 V；4 A 至 5,2 A 0 W 至 615 W CMC 0,62 mW/VA 25 V 至 30 V；5,2 A 至 8 A 0 W 至 615 W CMC 0,85 mW/VA 25 V 至 30 V；8 A 至 10 A 0 W 至 615 W CMC 0,62 mW/VA 25 V 至 30 V；10 A 至 15 A 0 W 至 615 W CMC 0,87 mW/VA 25 V 至 30 V；15 A 至 20,5 A 0 W 至 615 W CMC 0,65 mW/VA 30 V 至 50 V；150 mA 至 200 mA 0 W 至 1,025 kW CMC 1,4 mW/VA 30 V 至 50 V；200 mA 至 250 mA 0 W 至 1,025 kW CMC 1,1 mW/VA 30 V 至 50 V；250 mA 至 300 mA 0 W 至 1,025 kW CMC 0,90 mW/VA 30 V 至 50 V；300 mA 至 400 mA 0 W 至 1,025 kW CMC 1,4 mW/VA 30 V 至 50 V；400 mA 至 500 mA 0 W 至 1,025 kW CMC 1,1 mW/VA 30 V 至 50 V；500 mA 至 600 mA 0 W 至 1,025 kW CMC 0,90 mW/VA 30 V 至 50 V；600 mA 至 800 mA 0 W 至 1,025 kW CMC 1,4 mW/VA 30 V 至 50 V；800 mA 至 1 A 0 W 至 1,025 kW CMC 1,1 mW/VA 30 V 至 50 V；1 A 至 1,3 A 0 W 至 1,025 kW CMC 0,90 mW/VA 30 V 至 50 V；1,3 A 至 2 A 0 W 至 1,025 kW CMC 1,3 mW/VA 30 V 至 50 V；2 A 至 2,6 A 0 W 至 1,025 kW CMC 0,90 mW/VA 30 V 至 50 V；2,6 A 至 4 A 0 W 至 1,025 kW CMC 1,3 mW/VA 30 V 至 50 V；4 A 至 5,2 A 0 W 至 1,025 kW CMC 0,90 mW/VA 30 V 至 50 V；5,2 A 至 8 A 0 W 至 1,025 kW CMC 1,3 mW/VA 30 V 至 50 V；8 A 至 10 A 0 W 至 1,025 kW CMC 0,90 mW/VA 30 V 至 50 V；10 A 至 15 A 0 W 至 1,025 kW CMC 1,4 mW/VA 30 V 至 50 V；15 A 至 20,5 A 0 W 至 1,025 kW CMC 0,95 mW/VA 50 V 至 60 V；150 mA 至 200 mA 0 W 至 1,23 kW CMC 0,90 mW/VA 50 V 至 60 V；200 mA 至 300 mA 0 W 至 1,23 kW CMC 0,72 mW/VA 50 V 至 60 V；300 mA 至 400 mA 0 W 至 1,23 kW CMC 0,90 mW/VA 50 V 至 60 V；400 mA 至 600 mA 0 W 至 1,23 kW CMC 0,72 mW/VA 50 V 至 60 V；600 mA 至 800 mA 0 W 至 1,23 kW CMC 0,90 mW/VA 50 V 至 60 V；800 mA 至 1,3 A 0 W 至 1,23 kW CMC 0,72 mW/VA 50 V 至 60 V；1,3 A 至 2 A 0 W 至 1,23 kW CMC 0,85 mW/VA 50 V 至 60 V；2 A 至 2,6 A 0 W 至 1,23 kW CMC 0,62 mW/VA 50 V 至 60 V；2,6 A 至 4 A 0 W 至 1,23 kW CMC 0,85 mW/VA 50 V 至 60 V；4 A 至 5,2 A 0 W 至 1,23 kW CMC 0,62 mW/VA 50 V 至 60 V；5,2 A 至 8 A 0 W 至 1,23 kW CMC 0,85 mW/VA 50 V 至 60 V；8 A 至 10 A 0 W 至 1,23 kW CMC 0,62 mW/VA 50 V 至 60 V；10 A 至 15 A 0 W 至 1,23 kW CMC 0,87 mW/VA 50 V 至 60 V；15 A 至 20,5 A 0 W 至 1,23 kW CMC 0,65 mW/VA 60 V 至 120 V；150 mA 至 200 mA 0 W 至 2,46 kW CMC 1,4 mW/VA 60 V 至 120 V；200 mA 至 250 mA 0 W 至 2,46 kW CMC 1,1 mW/VA 60 V 至 120 V；250 mA 至 300 mA 0 W 至 2,46 kW CMC 0,90 mW/VA 60 V 至 120 V；300 mA 至 400 mA 0 W 至 2,46 kW CMC 1,4 mW/VA 60 V 至 120 V；400 mA 至 500 mA 0 W 至 2,46 kW CMC 1,1 mW/VA 60 V 至 120 V；500 mA 至 600 mA 0 W 至 2,46 kW CMC 0,90 mW/VA 60 V 至 120 V；600 mA 至 800 mA 0 W 至 2,46 kW CMC 1,4 mW/VA 60 V 至 120 V；800 mA 至 1 A 0 W 至 2,46 kW CMC 1,1 mW/VA 60 V 至 120 V；1 A 至 1,3 A 0 W 至 2,46 kW CMC 0,90 mW/VA 60 V 至 120 V；1,3 A 至 2 A 0 W 至 2,46 kW CMC 1,3 mW/VA 60 V 至 120 V；2 A 至 2,6 A 0 W 至 2,46 kW CMC 0,90 mW/VA 60 V 至 120 V；2,6 A 至 4 A 0 W 至 2,46 kW CMC 1,3 mW/VA 60 V 至 120 V；4 A 至 5,2 A 0 W 至 2,46 kW CMC 0,90 mW/VA 60 V 至 120 V；5,2 A 至 8 A 0 W 至 2,46 kW CMC 1,3 mW/VA 60 V 至 120 V；8 A 至 10 A 0 W 至 2,46 kW CMC 0,90 mW/VA 60 V 至 120 V；10 A 至 15 A 0 W 至 2,46 kW CMC 1,4 mW/VA 60 V 至 120 V；15 A 至 20,5 A 0 W 至 2,46 kW CMC 0,95 mW/VA 120 V 至 130 V；150 mA 至 200 mA 0 W 至 2,665 kW CMC 0,80 mW/VA 120 V 至 130 V；200 mA 至 300 mA 0 W 至 2,665 kW CMC 0,65 mW/VA 120 V 至 130 V；300 mA 至 400 mA 0 W 至 2,665 kW CMC 0,81 mW/VA 120 V 至 130 V；400 mA 至 600 mA 0 W 至 2,665 kW CMC 0,65 mW/VA 120 V 至 130 V；600 mA 至 800 mA 0 W 至 2,665 kW CMC 0,80 mW/VA 120 V 至 130 V；800 mA 至 1 A 0 W 至 2,665 kW CMC 0,65 mW/VA 120 V 至 130 V；1 A 至 1,3 A 0 W 至 2,665 kW CMC 0,56 mW/VA 120 V 至 130 V；1,3 A 至 2 A 0 W 至 2,665 kW CMC 0,76 mW/VA 120 V 至 130 V；2 A 至 2,6 A 0 W 至 2,665 kW CMC 0,56 mW/VA 120 V 至 130 V；2,6 A 至 4 A 0 W 至 2,665 kW CMC 0,76 mW/VA 120 V 至 130 V；4 A 至 5,2 A 0 W 至 2,665 kW CMC 0,56 mW/VA 120 V 至 130 V；5,2 A 至 8 A 0 W 至 2,665 kW CMC 0,76 mW/VA 120 V 至 130 V；8 A 至 10 A 0 W 至 2,665 kW CMC 0,56 mW/VA 120 V 至 130 V；10 A 至 15 A 0 W 至 2,665 kW CMC 0,78 mW/VA 120 V 至 130 V；15 A 至 20,5 A 0 W 至 2,665 kW CMC 0,59 mW/VA 130 V 至 230 V；150 mA 至 200 mA 0 W 至 4,715 kW CMC 1,4 mW/VA 130 V 至 230 V；200 mA 至 250 mA 0 W 至 4,715 kW CMC 1,1 mW/VA 130 V 至 230 V；250 mA 至 300 mA 0 W 至 4,715 kW CMC 0,90 mW/VA 130 V 至 230 V；300 mA 至 400 mA 0 W 至 4,715 kW CMC 1,4 mW/VA 130 V 至 230 V；400 mA 至 500 mA 0 W 至 4,715 kW CMC 1,1 mW/VA 130 V 至 230 V；500 mA 至 600 mA 0 W 至 4,715 kW CMC 0,90 mW/VA 130 V 至 230 V；600 mA 至 800 mA 0 W 至 4,715 kW CMC 1,4 mW/VA 130 V 至 230 V；800 mA 至 1 A 0 W 至 4,715 kW CMC 1,1 mW/VA 130 V 至 230 V；1 A 至 1,3 A 0 W 至 4,715 kW CMC 0,90 mW/VA 130 V 至 230 V；1,3 A 至 2 A 0 W 至 4,715 kW CMC 1,3 mW/VA 130 V 至 230 V；2 A 至 2,6 A 0 W 至 4,715 kW CMC 0,90 mW/VA 130 V 至 230 V；2,6 A 至 4 A 0 W 至 4,715 kW CMC 1,3 mW/VA 130 V 至 230 V；4 A 至 5,2 A 0 W 至 4,715 kW CMC 0,90 mW/VA 130 V 至 230 V；5,2 A 至 8 A 0 W 至 4,715 kW CMC 1,3 mW/VA 130 V 至 230 V；8 A 至 10 A 0 W 至 4,715 kW CMC 0,90 mW/VA 130 V 至 230 V；10 A 至 15 A 0 W 至 4,715 kW CMC 1,4 mW/VA 130 V 至 230 V；15 A 至 20,5 A 0 W 至 4,715 kW CMC 0,95 mW/VA 230 V 至 270 V；150 mA 至 200 mA 0 W 至 5,535 kW CMC 0,80 mW/VA 230 V 至 270 V；200 mA 至 300 mA 0 W 至 5,535 kW CMC 0,65 mW/VA 230 V 至 270 V；300 mA 至 400 mA 0 W 至 5,535 kW CMC 0,81 mW/VA 230 V 至 270 V；400 mA 至 600 mA 0 W 至 5,535 kW CMC 0,65 mW/VA 230 V 至 270 V；600 mA 至 800 mA 0 W 至 5,535 kW CMC 0,80 mW/VA 230 V 至 270 V；800 mA 至 1 A 0 W 至 5,535 kW CMC 0,65 mW/VA 230 V 至 270 V；1 A 至 1,3 A 0 W 至 5,535 kW CMC 0,56 mW/VA 230 V 至 270 V；1,3 A 至 2 A 0 W 至 5,535 kW CMC 0,76 mW/VA 230 V 至 270 V；2 A 至 2,6 A 0 W 至 5,535 kW CMC 0,56 mW/VA 230 V 至 270 V；2,6 A 至 4 A 0 W 至 5,535 kW CMC 0,76 mW/VA 230 V 至 270 V；4 A 至 5,2 A 0 W 至 5,535 kW CMC 0,56 mW/VA 230 V 至 270 V；5,2 A 至 8 A 0 W 至 5,535 kW CMC 0,76 mW/VA 230 V 至 270 V；8 A 至 10 A 0 W 至 5,535 kW CMC 0,56 mW/VA 230 V 至 270 V；10 A 至 15 A 0 W 至 5,535 kW CMC 0,78 mW/VA 230 V 至 270 V；15 A 至 20,5 A 0 W 至 5,535 kW CMC 0,59 mW/VA 270 V 至 540 V；150 mA 至 200 mA 0 W 至 11,07 kW CMC 1,4 mW/VA 270 V 至 540 V；200 mA 至 250 mA 0 W 至 11,07 kW CMC 1,1 mW/VA 270 V 至 540 V；250 mA 至 300 mA 0 W 至 11,07 kW CMC 0,90 mW/VA 270 V 至 540 V；300 mA 至 400 mA 0 W 至 11,07 kW CMC 1,4 mW/VA 270 V 至 540 V；400 mA 至 500 mA 0 W 至 11,07 kW CMC 1,1 mW/VA 270 V 至 540 V；500 mA 至 600 mA 0 W 至 11,07 kW CMC 0,90 mW/VA 270 V 至 540 V；600 mA 至 800 mA 0 W 至 11,07 kW CMC 1,4 mW/VA 270 V 至 540 V；800 mA 至 1 A 0 W 至 11,07 kW CMC 1,1 mW/VA 270 V 至 540 V；1 A 至 1,3 A 0 W 至 11,07 kW CMC 0,90 mW/VA 270 V 至 540 V；1,3 A 至 2 A 0 W 至 11,07 kW CMC 1,3 mW/VA 270 V 至 540 V；2 A 至 2,6 A 0 W 至 11,07 kW CMC 0,90 mW/VA 270 V 至 540 V；2,6 A 至 4 A 0 W 至 11,07 kW CMC 1,3 mW/VA 270 V 至 540 V；4 A 至 5,2 A 0 W 至 11,07 kW CMC 0,90 mW/VA 270 V 至 540 V；5,2 A 至 8 A 0 W 至 11,07 kW CMC 1,3 mW/VA 270 V 至 540 V；8 A 至 10 A 0 W 至 11,07 kW CMC 0,90 mW/VA 270 V 至 540 V；10 A 至 15 A 0 W 至 11,07 kW CMC 1,4 mW/VA 270 V 至 540 V；15 A 至 20,5 A 0 W 至 11,07 kW CMC 0,95 mW/VA 540 V 至 560 V；150 mA 至 200 mA 0 W 至 11,48 kW CMC 0,80 mW/VA 540 V 至 560 V；200 mA 至 300 mA 0 W 至 11,48 kW CMC 0,65 mW/VA 540 V 至 560 V；300 mA 至 400 mA 0 W 至 11,48 kW CMC 0,81 mW/VA 540 V 至 560 V；400 mA 至 600 mA 0 W 至 11,48 kW CMC 0,65 mW/VA 540 V 至 560 V；600 mA 至 800 mA 0 W 至 11,48 kW CMC 0,80 mW/VA 540 V 至 560 V；800 mA 至 1 A 0 W 至 11,48 kW CMC 0,65 mW/VA 540 V 至 560 V；1 A 至 1,3 A 0 W 至 11,48 kW CMC 0,56 mW/VA 540 V 至 560 V；1,3 A 至 2 A 0 W 至 11,48 kW CMC 0,76 mW/VA 540 V 至 560 V；2 A 至 2,6 A 0 W 至 11,48 kW CMC 0,56 mW/VA 540 V 至 560 V；2,6 A 至 4 A 0 W 至 11,48 kW CMC 0,76 mW/VA 540 V 至 560 V；4 A 至 5,2 A 0 W 至 11,48 kW CMC 0,56 mW/VA 540 V 至 560 V；5,2 A 至 8 A 0 W 至 11,48 kW CMC 0,76 mW/VA 540 V 至 560 V；8 A 至 10 A 0 W 至 11,48 kW CMC 0,56 mW/VA 540 V 至 560 V；10 A 至 15 A 0 W 至 11,48 kW CMC 0,78 mW/VA 540 V 至 560 V；15 A 至 20,5 A 0 W 至 11,48 kW CMC 0,59 mW/VA 560 V 至 700 V；150 mA 至 200 mA 0 W 至 14,35 kW CMC 1,4 mW/VA 560 V 至 700 V；200 mA 至 250 mA 0 W 至 14,35 kW CMC 1,1 mW/VA 560 V 至 700 V；250 mA 至 300 mA 0 W 至 14,35 kW CMC 0,90 mW/VA 560 V 至 700 V；300 mA 至 400 mA 0 W 至 14,35 kW CMC 1,4 mW/VA 560 V 至 700 V；400 mA 至 500 mA 0 W 至 14,35 kW CMC 1,1 mW/VA 560 V 至 700 V；500 mA 至 600 mA 0 W 至 14,35 kW CMC 0,90 mW/VA 560 V 至 700 V；600 mA 至 800 mA 0 W 至 14,35 kW CMC 1,4 mW/VA 560 V 至 700 V；800 mA 至 1 A 0 W 至 14,35 kW CMC 1,1 mW/VA 560 V 至 700 V；1 A 至 1,3 A 0 W 至 14,35 kW CMC 0,90 mW/VA 560 V 至 700 V；1,3 A 至 2 A 0 W 至 14,35 kW CMC 1,3 mW/VA 560 V 至 700 V；2 A 至 2,6 A 0 W 至 14,35 kW CMC 0,90 mW/VA 560 V 至 700 V；2,6 A 至 4 A 0 W 至 14,35 kW CMC 1,3 mW/VA 560 V 至 700 V；4 A 至 5,2 A 0 W 至 14,35 kW CMC 0,90 mW/VA 560 V 至 700 V；5,2 A 至 8 A 0 W 至 14,35 kW CMC 1,3 mW/VA 560 V 至 700 V；8 A 至 10 A 0 W 至 14,35 kW CMC 0,90 mW/VA 560 V 至 700 V；10 A 至 15 A 0 W 至 14,35 kW CMC 1,4 mW/VA 560 V 至 700 V；15 A 至 20,5 A 0 W 至 14,35 kW CMC 0,95 mW/VA 700 V 至 720 V；150 mA 至 200 mA 0 W 至 14,76 kW CMC 1,1 mW/VA 700 V 至 720 V；200 mA 至 250 mA 0 W 至 14,76 kW CMC 0,80 mW/VA 700 V 至 720 V；250 mA 至 300 mA 0 W 至 14,76 kW CMC 0,68 mW/VA 700 V 至 720 V；300 mA 至 400 mA 0 W 至 14,76 kW CMC 1,0 mW/VA 700 V 至 720 V；400 mA 至 500 mA 0 W 至 14,76 kW CMC 0,80 mW/VA 700 V 至 720 V；500 mA 至 600 mA 0 W 至 14,76 kW CMC 0,68 mW/VA 700 V 至 720 V；600 mA 至 800 mA 0 W 至 14,76 kW CMC 1,0 mW/VA 700 V 至 720 V；800 mA 至 1 A 0 W 至 14,76 kW CMC 0,80 mW/VA 700 V 至 720 V；1 A 至 1,3 A 0 W 至 14,76 kW CMC 0,68 mW/VA 700 V 至 720 V；1,3 A 至 2 A 0 W 至 14,76 kW CMC 0,94 mW/VA 700 V 至 720 V；2 A 至 2,6 A 0 W 至 14,76 kW CMC 0,68 mW/VA 700 V 至 720 V；2,6 A 至 4 A 0 W 至 14,76 kW CMC 0,94 mW/VA 700 V 至 720 V；4 A 至 5,2 A 0 W 至 14,76 kW CMC 0,68 mW/VA 700 V 至 720 V；5,2 A 至 8 A 0 W 至 14,76 kW CMC 0,94 mW/VA 700 V 至 720 V；8 A 至 10 A 0 W 至 14,76 kW CMC 0,68 mW/VA 700 V 至 720 V；10 A 至 15 A 0 W 至 14,76 kW CMC 0,97 mW/VA 700 V 至 720 V；15 A 至 20,5 A 0 W 至 14,76 kW CMC 0,71 mW/VA TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"00276438df6fb071dcfcb482","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"18","test_object":"Moc czynna prądu przemiennego jedno- i trójfazowa / Watomierze prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 1)","test_object_en":"AC active power, single-phase and three-phase / AC wattmeters, single-phase and three-phase (f: 45 Hz to 65 Hz, PF = 1)","test_object_zh":"单相和三相交流有功功率 / 单相和三相交流功率计（f：45 Hz 至 65 Hz，PF = 1）","test_object_cs":"Střídavý činný výkon jednofázový i třífázový / Střídavé wattmetry jednofázové i třífázové (f: 45 Hz až 65 Hz, PF = 1)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"33 mV do 1 V; 3,3 mA do 9 mA","range":"od 0,1 mW do 54 kW","cmc":"0,40 %"},{"name":"33 mV do 1 V; 9 mA do 33 mA","range":"od 0,1 mW do 54 kW","cmc":"0,25 %"},{"name":"33 mV do 1 V; 33 mA do 90 mA","range":"od 0,1 mW do 54 kW","cmc":"0,35 %"},{"name":"33 mV do 1 V; 90 mA do 100 mA","range":"od 0,1 mW do 54 kW","cmc":"0,25 %"},{"name":"1 V do 5 V; 100 mA do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,20 %"},{"name":"1 V do 5 V; 0,3 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,18 %"},{"name":"5 V do 10 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"5 V do 10 V; 0,3 A do 0,7 A","range":"od 0,1 mW do 54 kW","cmc":"0,11 %"},{"name":"5 V do 10 V; 0,7 A do 1 A","range":"od 0,1 mW do 54 kW","cmc":"0,09 %"},{"name":"5 V do 10 V; 1 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"10 V do 30 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,16 %"},{"name":"10 V do 30 V; 0,3 A do 10 A","range":"od 0,1 mW do 54 kW","cmc":"0,11 %"},{"name":"10 V do 30 V; 10 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,13 %"},{"name":"30 V do 50 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,16 %"},{"name":"30 V do 50 V; 0,3 A do 0,9 A","range":"od 0,1 mW do 54 kW","cmc":"0,11 %"},{"name":"30 V do 50 V; 0,9 A do 1 A","range":"od 0,1 mW do 54 kW","cmc":"0,09 %"},{"name":"30 V do 50 V; 1 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"50 V do 70 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"50 V do 70 V; 0,3 A do 0,7 A","range":"od 0,1 mW do 54 kW","cmc":"0,10 %"},{"name":"50 V do 70 V; 0,7 A do 1 A","range":"od 0,1 mW do 54 kW","cmc":"0,09 %"},{"name":"50 V do 70 V; 1 A do 10 A","range":"od 0,1 mW do 54 kW","cmc":"0,10 %"},{"name":"50 V do 70 V; 10 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"70 V do 100 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"70 V do 100 V; 0,3 A do 0,7 A","range":"od 0,1 mW do 54 kW","cmc":"0,11 %"},{"name":"70 V do 100 V; 0,7 A do 1 A","range":"od 0,1 mW do 54 kW","cmc":"0,09 %"},{"name":"70 V do 100 V; 1 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"100 V do 140 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"100 V do 140 V; 0,3 A do 1 A","range":"od 0,1 mW do 54 kW","cmc":"0,09 %"},{"name":"100 V do 140 V; 1 A do 10 A","range":"od 0,1 mW do 54 kW","cmc":"0,10 %"},{"name":"100 V do 140 V; 10 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"140 V do 200 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,19 %"},{"name":"140 V do 200 V; 0,3 A do 0,7 A","range":"od 0,1 mW do 54 kW","cmc":"0,11 %"},{"name":"140 V do 200 V; 0,7 A do 1 A","range":"od 0,1 mW do 54 kW","cmc":"0,09 %"},{"name":"140 V do 200 V; 1 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"200 V do 280 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"200 V do 280 V; 0,3 A do 0,7 A","range":"od 0,1 mW do 54 kW","cmc":"0,10 %"},{"name":"200 V do 280 V; 0,7 A do 1 A","range":"od 0,1 mW do 54 kW","cmc":"0,09 %"},{"name":"200 V do 280 V; 1 A do 10 A","range":"od 0,1 mW do 54 kW","cmc":"0,10 %"},{"name":"200 V do 280 V; 10 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"280 V do 400 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,16 %"},{"name":"280 V do 400 V; 0,3 A do 0,5 A","range":"od 0,1 mW do 54 kW","cmc":"0,11 %"},{"name":"280 V do 400 V; 0,5 A do 5 A","range":"od 0,1 mW do 54 kW","cmc":"0,10 %"},{"name":"280 V do 400 V; 5 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"400 V do 600 V; 0,1 A do 0,3 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"400 V do 600 V; 0,3 A do 0,5 A","range":"od 0,1 mW do 54 kW","cmc":"0,11 %"},{"name":"400 V do 600 V; 0,5 A do 10 A","range":"od 0,1 mW do 54 kW","cmc":"0,10 %"},{"name":"400 V do 600 V; 10 A do 90 A","range":"od 0,1 mW do 54 kW","cmc":"0,12 %"},{"name":"600 V do 1000 V; 100 mA do 330 mA","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"600 V do 1000 V; 0,33 A do 0,9 A","range":"od 0,1 mW do 54 kW","cmc":"0,25 %"},{"name":"600 V do 1000 V; 0,9 A do 2,2 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"},{"name":"600 V do 1000 V; 2,2 A do 4,5 A","range":"od 0,1 mW do 54 kW","cmc":"0,20 %"},{"name":"600 V do 1000 V; 4,5 A do 11 A","range":"od 0,1 mW do 54 kW","cmc":"0,15 %"}],"parameters_en":[{"name":"33 mV to 1 V; 3,3 mA to 9 mA","range":"0,1 mW to 54 kW","cmc":"0,40 %"},{"name":"33 mV to 1 V; 9 mA to 33 mA","range":"0,1 mW to 54 kW","cmc":"0,25 %"},{"name":"33 mV to 1 V; 33 mA to 90 mA","range":"0,1 mW to 54 kW","cmc":"0,35 %"},{"name":"33 mV to 1 V; 90 mA to 100 mA","range":"0,1 mW to 54 kW","cmc":"0,25 %"},{"name":"1 V to 5 V; 100 mA to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,20 %"},{"name":"1 V to 5 V; 0,3 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,18 %"},{"name":"5 V to 10 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"5 V to 10 V; 0,3 A to 0,7 A","range":"0,1 mW to 54 kW","cmc":"0,11 %"},{"name":"5 V to 10 V; 0,7 A to 1 A","range":"0,1 mW to 54 kW","cmc":"0,09 %"},{"name":"5 V to 10 V; 1 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"10 V to 30 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,16 %"},{"name":"10 V to 30 V; 0,3 A to 10 A","range":"0,1 mW to 54 kW","cmc":"0,11 %"},{"name":"10 V to 30 V; 10 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,13 %"},{"name":"30 V to 50 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,16 %"},{"name":"30 V to 50 V; 0,3 A to 0,9 A","range":"0,1 mW to 54 kW","cmc":"0,11 %"},{"name":"30 V to 50 V; 0,9 A to 1 A","range":"0,1 mW to 54 kW","cmc":"0,09 %"},{"name":"30 V to 50 V; 1 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"50 V to 70 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"50 V to 70 V; 0,3 A to 0,7 A","range":"0,1 mW to 54 kW","cmc":"0,10 %"},{"name":"50 V to 70 V; 0,7 A to 1 A","range":"0,1 mW to 54 kW","cmc":"0,09 %"},{"name":"50 V to 70 V; 1 A to 10 A","range":"0,1 mW to 54 kW","cmc":"0,10 %"},{"name":"50 V to 70 V; 10 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"70 V to 100 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"70 V to 100 V; 0,3 A to 0,7 A","range":"0,1 mW to 54 kW","cmc":"0,11 %"},{"name":"70 V to 100 V; 0,7 A to 1 A","range":"0,1 mW to 54 kW","cmc":"0,09 %"},{"name":"70 V to 100 V; 1 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"100 V to 140 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"100 V to 140 V; 0,3 A to 1 A","range":"0,1 mW to 54 kW","cmc":"0,09 %"},{"name":"100 V to 140 V; 1 A to 10 A","range":"0,1 mW to 54 kW","cmc":"0,10 %"},{"name":"100 V to 140 V; 10 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"140 V to 200 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,19 %"},{"name":"140 V to 200 V; 0,3 A to 0,7 A","range":"0,1 mW to 54 kW","cmc":"0,11 %"},{"name":"140 V to 200 V; 0,7 A to 1 A","range":"0,1 mW to 54 kW","cmc":"0,09 %"},{"name":"140 V to 200 V; 1 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"200 V to 280 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"200 V to 280 V; 0,3 A to 0,7 A","range":"0,1 mW to 54 kW","cmc":"0,10 %"},{"name":"200 V to 280 V; 0,7 A to 1 A","range":"0,1 mW to 54 kW","cmc":"0,09 %"},{"name":"200 V to 280 V; 1 A to 10 A","range":"0,1 mW to 54 kW","cmc":"0,10 %"},{"name":"200 V to 280 V; 10 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"280 V to 400 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,16 %"},{"name":"280 V to 400 V; 0,3 A to 0,5 A","range":"0,1 mW to 54 kW","cmc":"0,11 %"},{"name":"280 V to 400 V; 0,5 A to 5 A","range":"0,1 mW to 54 kW","cmc":"0,10 %"},{"name":"280 V to 400 V; 5 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"400 V to 600 V; 0,1 A to 0,3 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"400 V to 600 V; 0,3 A to 0,5 A","range":"0,1 mW to 54 kW","cmc":"0,11 %"},{"name":"400 V to 600 V; 0,5 A to 10 A","range":"0,1 mW to 54 kW","cmc":"0,10 %"},{"name":"400 V to 600 V; 10 A to 90 A","range":"0,1 mW to 54 kW","cmc":"0,12 %"},{"name":"600 V to 1000 V; 100 mA to 330 mA","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"600 V to 1000 V; 0,33 A to 0,9 A","range":"0,1 mW to 54 kW","cmc":"0,25 %"},{"name":"600 V to 1000 V; 0,9 A to 2,2 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"},{"name":"600 V to 1000 V; 2,2 A to 4,5 A","range":"0,1 mW to 54 kW","cmc":"0,20 %"},{"name":"600 V to 1000 V; 4,5 A to 11 A","range":"0,1 mW to 54 kW","cmc":"0,15 %"}],"parameters_zh":[{"name":"33 mV 至 1 V；3,3 mA 至 9 mA","range":"0,1 mW 至 54 kW","cmc":"0,40 %"},{"name":"33 mV 至 1 V；9 mA 至 33 mA","range":"0,1 mW 至 54 kW","cmc":"0,25 %"},{"name":"33 mV 至 1 V；33 mA 至 90 mA","range":"0,1 mW 至 54 kW","cmc":"0,35 %"},{"name":"33 mV 至 1 V；90 mA 至 100 mA","range":"0,1 mW 至 54 kW","cmc":"0,25 %"},{"name":"1 V 至 5 V；100 mA 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,20 %"},{"name":"1 V 至 5 V；0,3 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,18 %"},{"name":"5 V 至 10 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"5 V 至 10 V；0,3 A 至 0,7 A","range":"0,1 mW 至 54 kW","cmc":"0,11 %"},{"name":"5 V 至 10 V；0,7 A 至 1 A","range":"0,1 mW 至 54 kW","cmc":"0,09 %"},{"name":"5 V 至 10 V；1 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"10 V 至 30 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,16 %"},{"name":"10 V 至 30 V；0,3 A 至 10 A","range":"0,1 mW 至 54 kW","cmc":"0,11 %"},{"name":"10 V 至 30 V；10 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,13 %"},{"name":"30 V 至 50 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,16 %"},{"name":"30 V 至 50 V；0,3 A 至 0,9 A","range":"0,1 mW 至 54 kW","cmc":"0,11 %"},{"name":"30 V 至 50 V；0,9 A 至 1 A","range":"0,1 mW 至 54 kW","cmc":"0,09 %"},{"name":"30 V 至 50 V；1 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"50 V 至 70 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"50 V 至 70 V；0,3 A 至 0,7 A","range":"0,1 mW 至 54 kW","cmc":"0,10 %"},{"name":"50 V 至 70 V；0,7 A 至 1 A","range":"0,1 mW 至 54 kW","cmc":"0,09 %"},{"name":"50 V 至 70 V；1 A 至 10 A","range":"0,1 mW 至 54 kW","cmc":"0,10 %"},{"name":"50 V 至 70 V；10 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"70 V 至 100 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"70 V 至 100 V；0,3 A 至 0,7 A","range":"0,1 mW 至 54 kW","cmc":"0,11 %"},{"name":"70 V 至 100 V；0,7 A 至 1 A","range":"0,1 mW 至 54 kW","cmc":"0,09 %"},{"name":"70 V 至 100 V；1 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"100 V 至 140 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"100 V 至 140 V；0,3 A 至 1 A","range":"0,1 mW 至 54 kW","cmc":"0,09 %"},{"name":"100 V 至 140 V；1 A 至 10 A","range":"0,1 mW 至 54 kW","cmc":"0,10 %"},{"name":"100 V 至 140 V；10 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"140 V 至 200 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,19 %"},{"name":"140 V 至 200 V；0,3 A 至 0,7 A","range":"0,1 mW 至 54 kW","cmc":"0,11 %"},{"name":"140 V 至 200 V；0,7 A 至 1 A","range":"0,1 mW 至 54 kW","cmc":"0,09 %"},{"name":"140 V 至 200 V；1 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"200 V 至 280 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"200 V 至 280 V；0,3 A 至 0,7 A","range":"0,1 mW 至 54 kW","cmc":"0,10 %"},{"name":"200 V 至 280 V；0,7 A 至 1 A","range":"0,1 mW 至 54 kW","cmc":"0,09 %"},{"name":"200 V 至 280 V；1 A 至 10 A","range":"0,1 mW 至 54 kW","cmc":"0,10 %"},{"name":"200 V 至 280 V；10 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"280 V 至 400 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,16 %"},{"name":"280 V 至 400 V；0,3 A 至 0,5 A","range":"0,1 mW 至 54 kW","cmc":"0,11 %"},{"name":"280 V 至 400 V；0,5 A 至 5 A","range":"0,1 mW 至 54 kW","cmc":"0,10 %"},{"name":"280 V 至 400 V；5 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"400 V 至 600 V；0,1 A 至 0,3 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"400 V 至 600 V；0,3 A 至 0,5 A","range":"0,1 mW 至 54 kW","cmc":"0,11 %"},{"name":"400 V 至 600 V；0,5 A 至 10 A","range":"0,1 mW 至 54 kW","cmc":"0,10 %"},{"name":"400 V 至 600 V；10 A 至 90 A","range":"0,1 mW 至 54 kW","cmc":"0,12 %"},{"name":"600 V 至 1000 V；100 mA 至 330 mA","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"600 V 至 1000 V；0,33 A 至 0,9 A","range":"0,1 mW 至 54 kW","cmc":"0,25 %"},{"name":"600 V 至 1000 V；0,9 A 至 2,2 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"},{"name":"600 V 至 1000 V；2,2 A 至 4,5 A","range":"0,1 mW 至 54 kW","cmc":"0,20 %"},{"name":"600 V 至 1000 V；4,5 A 至 11 A","range":"0,1 mW 至 54 kW","cmc":"0,15 %"}],"parameters_cs":[{"name":"33 mV až 1 V; 3,3 mA až 9 mA","range":"0,1 mW až 54 kW","cmc":"0,40 %"},{"name":"33 mV až 1 V; 9 mA až 33 mA","range":"0,1 mW až 54 kW","cmc":"0,25 %"},{"name":"33 mV až 1 V; 33 mA až 90 mA","range":"0,1 mW až 54 kW","cmc":"0,35 %"},{"name":"33 mV až 1 V; 90 mA až 100 mA","range":"0,1 mW až 54 kW","cmc":"0,25 %"},{"name":"1 V až 5 V; 100 mA až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,20 %"},{"name":"1 V až 5 V; 0,3 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,18 %"},{"name":"5 V až 10 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"5 V až 10 V; 0,3 A až 0,7 A","range":"0,1 mW až 54 kW","cmc":"0,11 %"},{"name":"5 V až 10 V; 0,7 A až 1 A","range":"0,1 mW až 54 kW","cmc":"0,09 %"},{"name":"5 V až 10 V; 1 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"10 V až 30 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,16 %"},{"name":"10 V až 30 V; 0,3 A až 10 A","range":"0,1 mW až 54 kW","cmc":"0,11 %"},{"name":"10 V až 30 V; 10 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,13 %"},{"name":"30 V až 50 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,16 %"},{"name":"30 V až 50 V; 0,3 A až 0,9 A","range":"0,1 mW až 54 kW","cmc":"0,11 %"},{"name":"30 V až 50 V; 0,9 A až 1 A","range":"0,1 mW až 54 kW","cmc":"0,09 %"},{"name":"30 V až 50 V; 1 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"50 V až 70 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"50 V až 70 V; 0,3 A až 0,7 A","range":"0,1 mW až 54 kW","cmc":"0,10 %"},{"name":"50 V až 70 V; 0,7 A až 1 A","range":"0,1 mW až 54 kW","cmc":"0,09 %"},{"name":"50 V až 70 V; 1 A až 10 A","range":"0,1 mW až 54 kW","cmc":"0,10 %"},{"name":"50 V až 70 V; 10 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"70 V až 100 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"70 V až 100 V; 0,3 A až 0,7 A","range":"0,1 mW až 54 kW","cmc":"0,11 %"},{"name":"70 V až 100 V; 0,7 A až 1 A","range":"0,1 mW až 54 kW","cmc":"0,09 %"},{"name":"70 V až 100 V; 1 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"100 V až 140 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"100 V až 140 V; 0,3 A až 1 A","range":"0,1 mW až 54 kW","cmc":"0,09 %"},{"name":"100 V až 140 V; 1 A až 10 A","range":"0,1 mW až 54 kW","cmc":"0,10 %"},{"name":"100 V až 140 V; 10 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"140 V až 200 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,19 %"},{"name":"140 V až 200 V; 0,3 A až 0,7 A","range":"0,1 mW až 54 kW","cmc":"0,11 %"},{"name":"140 V až 200 V; 0,7 A až 1 A","range":"0,1 mW až 54 kW","cmc":"0,09 %"},{"name":"140 V až 200 V; 1 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"200 V až 280 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"200 V až 280 V; 0,3 A až 0,7 A","range":"0,1 mW až 54 kW","cmc":"0,10 %"},{"name":"200 V až 280 V; 0,7 A až 1 A","range":"0,1 mW až 54 kW","cmc":"0,09 %"},{"name":"200 V až 280 V; 1 A až 10 A","range":"0,1 mW až 54 kW","cmc":"0,10 %"},{"name":"200 V až 280 V; 10 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"280 V až 400 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,16 %"},{"name":"280 V až 400 V; 0,3 A až 0,5 A","range":"0,1 mW až 54 kW","cmc":"0,11 %"},{"name":"280 V až 400 V; 0,5 A až 5 A","range":"0,1 mW až 54 kW","cmc":"0,10 %"},{"name":"280 V až 400 V; 5 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"400 V až 600 V; 0,1 A až 0,3 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"400 V až 600 V; 0,3 A až 0,5 A","range":"0,1 mW až 54 kW","cmc":"0,11 %"},{"name":"400 V až 600 V; 0,5 A až 10 A","range":"0,1 mW až 54 kW","cmc":"0,10 %"},{"name":"400 V až 600 V; 10 A až 90 A","range":"0,1 mW až 54 kW","cmc":"0,12 %"},{"name":"600 V až 1000 V; 100 mA až 330 mA","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"600 V až 1000 V; 0,33 A až 0,9 A","range":"0,1 mW až 54 kW","cmc":"0,25 %"},{"name":"600 V až 1000 V; 0,9 A až 2,2 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"},{"name":"600 V až 1000 V; 2,2 A až 4,5 A","range":"0,1 mW až 54 kW","cmc":"0,20 %"},{"name":"600 V až 1000 V; 4,5 A až 11 A","range":"0,1 mW až 54 kW","cmc":"0,15 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n33 mV do 1 V; 3,3 mA do 9 mA od 0,1 mW do 54 kW CMC 0,40 %\n33 mV do 1 V; 9 mA do 33 mA od 0,1 mW do 54 kW CMC 0,25 %\n33 mV do 1 V; 33 mA do 90 mA od 0,1 mW do 54 kW CMC 0,35 %\n33 mV do 1 V; 90 mA do 100 mA od 0,1 mW do 54 kW CMC 0,25 %\n1 V do 5 V; 100 mA do 0,3 A od 0,1 mW do 54 kW CMC 0,20 %\n1 V do 5 V; 0,3 A do 90 A od 0,1 mW do 54 kW CMC 0,18 %\n5 V do 10 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 %\n5 V do 10 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 %\n5 V do 10 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 %\n5 V do 10 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n10 V do 30 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 %\n10 V do 30 V; 0,3 A do 10 A od 0,1 mW do 54 kW CMC 0,11 %\n10 V do 30 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,13 %\n30 V do 50 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 %\n30 V do 50 V; 0,3 A do 0,9 A od 0,1 mW do 54 kW CMC 0,11 %\n30 V do 50 V; 0,9 A do 1 A od 0,1 mW do 54 kW CMC 0,09 %\n30 V do 50 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n50 V do 70 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 %\n50 V do 70 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,10 %\n50 V do 70 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 %\n50 V do 70 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 %\n50 V do 70 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n70 V do 100 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 %\n70 V do 100 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 %\n70 V do 100 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 %\n70 V do 100 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n100 V do 140 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 %\n100 V do 140 V; 0,3 A do 1 A od 0,1 mW do 54 kW CMC 0,09 %\n100 V do 140 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 %\n100 V do 140 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n140 V do 200 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,19 %\n140 V do 200 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 %\n140 V do 200 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 %\n140 V do 200 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n200 V do 280 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 %\n200 V do 280 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,10 %\n200 V do 280 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 %\n200 V do 280 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 %\n200 V do 280 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n280 V do 400 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 %\n280 V do 400 V; 0,3 A do 0,5 A od 0,1 mW do 54 kW CMC 0,11 %\n280 V do 400 V; 0,5 A do 5 A od 0,1 mW do 54 kW CMC 0,10 %\n280 V do 400 V; 5 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n400 V do 600 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 %\n400 V do 600 V; 0,3 A do 0,5 A od 0,1 mW do 54 kW CMC 0,11 %\n400 V do 600 V; 0,5 A do 10 A od 0,1 mW do 54 kW CMC 0,10 %\n400 V do 600 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 %\n600 V do 1000 V; 100 mA do 330 mA od 0,1 mW do 54 kW CMC 0,15 %\n600 V do 1000 V; 0,33 A do 0,9 A od 0,1 mW do 54 kW CMC 0,25 %\n600 V do 1000 V; 0,9 A do 2,2 A od 0,1 mW do 54 kW CMC 0,15 %\n600 V do 1000 V; 2,2 A do 4,5 A od 0,1 mW do 54 kW CMC 0,20 %\n600 V do 1000 V; 4,5 A do 11 A od 0,1 mW do 54 kW CMC 0,15 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego jedno- i trójfazowa / Watomierze prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 1) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 33 mV do 1 V; 3,3 mA do 9 mA od 0,1 mW do 54 kW CMC 0,40 % 33 mV do 1 V; 9 mA do 33 mA od 0,1 mW do 54 kW CMC 0,25 % 33 mV do 1 V; 33 mA do 90 mA od 0,1 mW do 54 kW CMC 0,35 % 33 mV do 1 V; 90 mA do 100 mA od 0,1 mW do 54 kW CMC 0,25 % 1 V do 5 V; 100 mA do 0,3 A od 0,1 mW do 54 kW CMC 0,20 % 1 V do 5 V; 0,3 A do 90 A od 0,1 mW do 54 kW CMC 0,18 % 5 V do 10 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 5 V do 10 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 % 5 V do 10 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 5 V do 10 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 10 V do 30 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 % 10 V do 30 V; 0,3 A do 10 A od 0,1 mW do 54 kW CMC 0,11 % 10 V do 30 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,13 % 30 V do 50 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 % 30 V do 50 V; 0,3 A do 0,9 A od 0,1 mW do 54 kW CMC 0,11 % 30 V do 50 V; 0,9 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 30 V do 50 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 50 V do 70 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 50 V do 70 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,10 % 50 V do 70 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 50 V do 70 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 50 V do 70 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 70 V do 100 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 70 V do 100 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 % 70 V do 100 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 70 V do 100 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 100 V do 140 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 100 V do 140 V; 0,3 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 100 V do 140 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 100 V do 140 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 140 V do 200 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,19 % 140 V do 200 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 % 140 V do 200 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 140 V do 200 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 200 V do 280 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 200 V do 280 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,10 % 200 V do 280 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 200 V do 280 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 200 V do 280 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 280 V do 400 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 % 280 V do 400 V; 0,3 A do 0,5 A od 0,1 mW do 54 kW CMC 0,11 % 280 V do 400 V; 0,5 A do 5 A od 0,1 mW do 54 kW CMC 0,10 % 280 V do 400 V; 5 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 400 V do 600 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 400 V do 600 V; 0,3 A do 0,5 A od 0,1 mW do 54 kW CMC 0,11 % 400 V do 600 V; 0,5 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 400 V do 600 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 600 V do 1000 V; 100 mA do 330 mA od 0,1 mW do 54 kW CMC 0,15 % 600 V do 1000 V; 0,33 A do 0,9 A od 0,1 mW do 54 kW CMC 0,25 % 600 V do 1000 V; 0,9 A do 2,2 A od 0,1 mW do 54 kW CMC 0,15 % 600 V do 1000 V; 2,2 A do 4,5 A od 0,1 mW do 54 kW CMC 0,20 % 600 V do 1000 V; 4,5 A do 11 A od 0,1 mW do 54 kW CMC 0,15 % Střídavý činný výkon jednofázový i třífázový / Střídavé wattmetry jednofázové i třífázové (f: 45 Hz až 65 Hz, PF = 1) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 33 mV až 1 V; 3,3 mA až 9 mA 0,1 mW až 54 kW CMC 0,40 % 33 mV až 1 V; 9 mA až 33 mA 0,1 mW až 54 kW CMC 0,25 % 33 mV až 1 V; 33 mA až 90 mA 0,1 mW až 54 kW CMC 0,35 % 33 mV až 1 V; 90 mA až 100 mA 0,1 mW až 54 kW CMC 0,25 % 1 V až 5 V; 100 mA až 0,3 A 0,1 mW až 54 kW CMC 0,20 % 1 V až 5 V; 0,3 A až 90 A 0,1 mW až 54 kW CMC 0,18 % 5 V až 10 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,15 % 5 V až 10 V; 0,3 A až 0,7 A 0,1 mW až 54 kW CMC 0,11 % 5 V až 10 V; 0,7 A až 1 A 0,1 mW až 54 kW CMC 0,09 % 5 V až 10 V; 1 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 10 V až 30 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,16 % 10 V až 30 V; 0,3 A až 10 A 0,1 mW až 54 kW CMC 0,11 % 10 V až 30 V; 10 A až 90 A 0,1 mW až 54 kW CMC 0,13 % 30 V až 50 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,16 % 30 V až 50 V; 0,3 A až 0,9 A 0,1 mW až 54 kW CMC 0,11 % 30 V až 50 V; 0,9 A až 1 A 0,1 mW až 54 kW CMC 0,09 % 30 V až 50 V; 1 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 50 V až 70 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,15 % 50 V až 70 V; 0,3 A až 0,7 A 0,1 mW až 54 kW CMC 0,10 % 50 V až 70 V; 0,7 A až 1 A 0,1 mW až 54 kW CMC 0,09 % 50 V až 70 V; 1 A až 10 A 0,1 mW až 54 kW CMC 0,10 % 50 V až 70 V; 10 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 70 V až 100 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,15 % 70 V až 100 V; 0,3 A až 0,7 A 0,1 mW až 54 kW CMC 0,11 % 70 V až 100 V; 0,7 A až 1 A 0,1 mW až 54 kW CMC 0,09 % 70 V až 100 V; 1 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 100 V až 140 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,15 % 100 V až 140 V; 0,3 A až 1 A 0,1 mW až 54 kW CMC 0,09 % 100 V až 140 V; 1 A až 10 A 0,1 mW až 54 kW CMC 0,10 % 100 V až 140 V; 10 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 140 V až 200 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,19 % 140 V až 200 V; 0,3 A až 0,7 A 0,1 mW až 54 kW CMC 0,11 % 140 V až 200 V; 0,7 A až 1 A 0,1 mW až 54 kW CMC 0,09 % 140 V až 200 V; 1 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 200 V až 280 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,15 % 200 V až 280 V; 0,3 A až 0,7 A 0,1 mW až 54 kW CMC 0,10 % 200 V až 280 V; 0,7 A až 1 A 0,1 mW až 54 kW CMC 0,09 % 200 V až 280 V; 1 A až 10 A 0,1 mW až 54 kW CMC 0,10 % 200 V až 280 V; 10 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 280 V až 400 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,16 % 280 V až 400 V; 0,3 A až 0,5 A 0,1 mW až 54 kW CMC 0,11 % 280 V až 400 V; 0,5 A až 5 A 0,1 mW až 54 kW CMC 0,10 % 280 V až 400 V; 5 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 400 V až 600 V; 0,1 A až 0,3 A 0,1 mW až 54 kW CMC 0,15 % 400 V až 600 V; 0,3 A až 0,5 A 0,1 mW až 54 kW CMC 0,11 % 400 V až 600 V; 0,5 A až 10 A 0,1 mW až 54 kW CMC 0,10 % 400 V až 600 V; 10 A až 90 A 0,1 mW až 54 kW CMC 0,12 % 600 V až 1000 V; 100 mA až 330 mA 0,1 mW až 54 kW CMC 0,15 % 600 V až 1000 V; 0,33 A až 0,9 A 0,1 mW až 54 kW CMC 0,25 % 600 V až 1000 V; 0,9 A až 2,2 A 0,1 mW až 54 kW CMC 0,15 % 600 V až 1000 V; 2,2 A až 4,5 A 0,1 mW až 54 kW CMC 0,20 % 600 V až 1000 V; 4,5 A až 11 A 0,1 mW až 54 kW CMC 0,15 % TP16 Moc czynna pradu przemiennego jedno- i trojfazowa / Watomierze pradu przemiennego jedno- i trojfazowe (f: 45 Hz do 65 Hz, PF = 1) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 33 mV do 1 V; 3,3 mA do 9 mA od 0,1 mW do 54 kW CMC 0,40 % 33 mV do 1 V; 9 mA do 33 mA od 0,1 mW do 54 kW CMC 0,25 % 33 mV do 1 V; 33 mA do 90 mA od 0,1 mW do 54 kW CMC 0,35 % 33 mV do 1 V; 90 mA do 100 mA od 0,1 mW do 54 kW CMC 0,25 % 1 V do 5 V; 100 mA do 0,3 A od 0,1 mW do 54 kW CMC 0,20 % 1 V do 5 V; 0,3 A do 90 A od 0,1 mW do 54 kW CMC 0,18 % 5 V do 10 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 5 V do 10 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 % 5 V do 10 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 5 V do 10 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 10 V do 30 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 % 10 V do 30 V; 0,3 A do 10 A od 0,1 mW do 54 kW CMC 0,11 % 10 V do 30 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,13 % 30 V do 50 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 % 30 V do 50 V; 0,3 A do 0,9 A od 0,1 mW do 54 kW CMC 0,11 % 30 V do 50 V; 0,9 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 30 V do 50 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 50 V do 70 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 50 V do 70 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,10 % 50 V do 70 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 50 V do 70 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 50 V do 70 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 70 V do 100 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 70 V do 100 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 % 70 V do 100 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 70 V do 100 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 100 V do 140 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 100 V do 140 V; 0,3 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 100 V do 140 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 100 V do 140 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 140 V do 200 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,19 % 140 V do 200 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,11 % 140 V do 200 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 140 V do 200 V; 1 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 200 V do 280 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 200 V do 280 V; 0,3 A do 0,7 A od 0,1 mW do 54 kW CMC 0,10 % 200 V do 280 V; 0,7 A do 1 A od 0,1 mW do 54 kW CMC 0,09 % 200 V do 280 V; 1 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 200 V do 280 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 280 V do 400 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,16 % 280 V do 400 V; 0,3 A do 0,5 A od 0,1 mW do 54 kW CMC 0,11 % 280 V do 400 V; 0,5 A do 5 A od 0,1 mW do 54 kW CMC 0,10 % 280 V do 400 V; 5 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 400 V do 600 V; 0,1 A do 0,3 A od 0,1 mW do 54 kW CMC 0,15 % 400 V do 600 V; 0,3 A do 0,5 A od 0,1 mW do 54 kW CMC 0,11 % 400 V do 600 V; 0,5 A do 10 A od 0,1 mW do 54 kW CMC 0,10 % 400 V do 600 V; 10 A do 90 A od 0,1 mW do 54 kW CMC 0,12 % 600 V do 1000 V; 100 mA do 330 mA od 0,1 mW do 54 kW CMC 0,15 % 600 V do 1000 V; 0,33 A do 0,9 A od 0,1 mW do 54 kW CMC 0,25 % 600 V do 1000 V; 0,9 A do 2,2 A od 0,1 mW do 54 kW CMC 0,15 % 600 V do 1000 V; 2,2 A do 4,5 A od 0,1 mW do 54 kW CMC 0,20 % 600 V do 1000 V; 4,5 A do 11 A od 0,1 mW do 54 kW CMC 0,15 % Stridavy cinny vykon jednofazovy i trifazovy / Stridave wattmetry jednofazove i trifazove (f: 45 Hz az 65 Hz, PF = 1) Kalibrace – elektricke veliciny Prime generovani kalibratorem 33 mV az 1 V; 3,3 mA az 9 mA 0,1 mW az 54 kW CMC 0,40 % 33 mV az 1 V; 9 mA az 33 mA 0,1 mW az 54 kW CMC 0,25 % 33 mV az 1 V; 33 mA az 90 mA 0,1 mW az 54 kW CMC 0,35 % 33 mV az 1 V; 90 mA az 100 mA 0,1 mW az 54 kW CMC 0,25 % 1 V az 5 V; 100 mA az 0,3 A 0,1 mW az 54 kW CMC 0,20 % 1 V az 5 V; 0,3 A az 90 A 0,1 mW az 54 kW CMC 0,18 % 5 V az 10 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,15 % 5 V az 10 V; 0,3 A az 0,7 A 0,1 mW az 54 kW CMC 0,11 % 5 V az 10 V; 0,7 A az 1 A 0,1 mW az 54 kW CMC 0,09 % 5 V az 10 V; 1 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 10 V az 30 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,16 % 10 V az 30 V; 0,3 A az 10 A 0,1 mW az 54 kW CMC 0,11 % 10 V az 30 V; 10 A az 90 A 0,1 mW az 54 kW CMC 0,13 % 30 V az 50 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,16 % 30 V az 50 V; 0,3 A az 0,9 A 0,1 mW az 54 kW CMC 0,11 % 30 V az 50 V; 0,9 A az 1 A 0,1 mW az 54 kW CMC 0,09 % 30 V az 50 V; 1 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 50 V az 70 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,15 % 50 V az 70 V; 0,3 A az 0,7 A 0,1 mW az 54 kW CMC 0,10 % 50 V az 70 V; 0,7 A az 1 A 0,1 mW az 54 kW CMC 0,09 % 50 V az 70 V; 1 A az 10 A 0,1 mW az 54 kW CMC 0,10 % 50 V az 70 V; 10 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 70 V az 100 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,15 % 70 V az 100 V; 0,3 A az 0,7 A 0,1 mW az 54 kW CMC 0,11 % 70 V az 100 V; 0,7 A az 1 A 0,1 mW az 54 kW CMC 0,09 % 70 V az 100 V; 1 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 100 V az 140 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,15 % 100 V az 140 V; 0,3 A az 1 A 0,1 mW az 54 kW CMC 0,09 % 100 V az 140 V; 1 A az 10 A 0,1 mW az 54 kW CMC 0,10 % 100 V az 140 V; 10 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 140 V az 200 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,19 % 140 V az 200 V; 0,3 A az 0,7 A 0,1 mW az 54 kW CMC 0,11 % 140 V az 200 V; 0,7 A az 1 A 0,1 mW az 54 kW CMC 0,09 % 140 V az 200 V; 1 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 200 V az 280 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,15 % 200 V az 280 V; 0,3 A az 0,7 A 0,1 mW az 54 kW CMC 0,10 % 200 V az 280 V; 0,7 A az 1 A 0,1 mW az 54 kW CMC 0,09 % 200 V az 280 V; 1 A az 10 A 0,1 mW az 54 kW CMC 0,10 % 200 V az 280 V; 10 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 280 V az 400 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,16 % 280 V az 400 V; 0,3 A az 0,5 A 0,1 mW az 54 kW CMC 0,11 % 280 V az 400 V; 0,5 A az 5 A 0,1 mW az 54 kW CMC 0,10 % 280 V az 400 V; 5 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 400 V az 600 V; 0,1 A az 0,3 A 0,1 mW az 54 kW CMC 0,15 % 400 V az 600 V; 0,3 A az 0,5 A 0,1 mW az 54 kW CMC 0,11 % 400 V az 600 V; 0,5 A az 10 A 0,1 mW az 54 kW CMC 0,10 % 400 V az 600 V; 10 A az 90 A 0,1 mW az 54 kW CMC 0,12 % 600 V az 1000 V; 100 mA az 330 mA 0,1 mW az 54 kW CMC 0,15 % 600 V az 1000 V; 0,33 A az 0,9 A 0,1 mW az 54 kW CMC 0,25 % 600 V az 1000 V; 0,9 A az 2,2 A 0,1 mW az 54 kW CMC 0,15 % 600 V az 1000 V; 2,2 A az 4,5 A 0,1 mW az 54 kW CMC 0,20 % 600 V az 1000 V; 4,5 A az 11 A 0,1 mW az 54 kW CMC 0,15 % TP16","search_en":"AC active power, single-phase and three-phase / AC wattmeters, single-phase and three-phase (f: 45 Hz to 65 Hz, PF = 1) Calibration – electrical quantities Direct generation with a calibrator 33 mV to 1 V; 3,3 mA to 9 mA 0,1 mW to 54 kW CMC 0,40 % 33 mV to 1 V; 9 mA to 33 mA 0,1 mW to 54 kW CMC 0,25 % 33 mV to 1 V; 33 mA to 90 mA 0,1 mW to 54 kW CMC 0,35 % 33 mV to 1 V; 90 mA to 100 mA 0,1 mW to 54 kW CMC 0,25 % 1 V to 5 V; 100 mA to 0,3 A 0,1 mW to 54 kW CMC 0,20 % 1 V to 5 V; 0,3 A to 90 A 0,1 mW to 54 kW CMC 0,18 % 5 V to 10 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,15 % 5 V to 10 V; 0,3 A to 0,7 A 0,1 mW to 54 kW CMC 0,11 % 5 V to 10 V; 0,7 A to 1 A 0,1 mW to 54 kW CMC 0,09 % 5 V to 10 V; 1 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 10 V to 30 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,16 % 10 V to 30 V; 0,3 A to 10 A 0,1 mW to 54 kW CMC 0,11 % 10 V to 30 V; 10 A to 90 A 0,1 mW to 54 kW CMC 0,13 % 30 V to 50 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,16 % 30 V to 50 V; 0,3 A to 0,9 A 0,1 mW to 54 kW CMC 0,11 % 30 V to 50 V; 0,9 A to 1 A 0,1 mW to 54 kW CMC 0,09 % 30 V to 50 V; 1 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 50 V to 70 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,15 % 50 V to 70 V; 0,3 A to 0,7 A 0,1 mW to 54 kW CMC 0,10 % 50 V to 70 V; 0,7 A to 1 A 0,1 mW to 54 kW CMC 0,09 % 50 V to 70 V; 1 A to 10 A 0,1 mW to 54 kW CMC 0,10 % 50 V to 70 V; 10 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 70 V to 100 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,15 % 70 V to 100 V; 0,3 A to 0,7 A 0,1 mW to 54 kW CMC 0,11 % 70 V to 100 V; 0,7 A to 1 A 0,1 mW to 54 kW CMC 0,09 % 70 V to 100 V; 1 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 100 V to 140 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,15 % 100 V to 140 V; 0,3 A to 1 A 0,1 mW to 54 kW CMC 0,09 % 100 V to 140 V; 1 A to 10 A 0,1 mW to 54 kW CMC 0,10 % 100 V to 140 V; 10 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 140 V to 200 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,19 % 140 V to 200 V; 0,3 A to 0,7 A 0,1 mW to 54 kW CMC 0,11 % 140 V to 200 V; 0,7 A to 1 A 0,1 mW to 54 kW CMC 0,09 % 140 V to 200 V; 1 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 200 V to 280 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,15 % 200 V to 280 V; 0,3 A to 0,7 A 0,1 mW to 54 kW CMC 0,10 % 200 V to 280 V; 0,7 A to 1 A 0,1 mW to 54 kW CMC 0,09 % 200 V to 280 V; 1 A to 10 A 0,1 mW to 54 kW CMC 0,10 % 200 V to 280 V; 10 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 280 V to 400 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,16 % 280 V to 400 V; 0,3 A to 0,5 A 0,1 mW to 54 kW CMC 0,11 % 280 V to 400 V; 0,5 A to 5 A 0,1 mW to 54 kW CMC 0,10 % 280 V to 400 V; 5 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 400 V to 600 V; 0,1 A to 0,3 A 0,1 mW to 54 kW CMC 0,15 % 400 V to 600 V; 0,3 A to 0,5 A 0,1 mW to 54 kW CMC 0,11 % 400 V to 600 V; 0,5 A to 10 A 0,1 mW to 54 kW CMC 0,10 % 400 V to 600 V; 10 A to 90 A 0,1 mW to 54 kW CMC 0,12 % 600 V to 1000 V; 100 mA to 330 mA 0,1 mW to 54 kW CMC 0,15 % 600 V to 1000 V; 0,33 A to 0,9 A 0,1 mW to 54 kW CMC 0,25 % 600 V to 1000 V; 0,9 A to 2,2 A 0,1 mW to 54 kW CMC 0,15 % 600 V to 1000 V; 2,2 A to 4,5 A 0,1 mW to 54 kW CMC 0,20 % 600 V to 1000 V; 4,5 A to 11 A 0,1 mW to 54 kW CMC 0,15 % TP16","search_zh":"单相和三相交流有功功率 / 单相和三相交流功率计（f：45 Hz 至 65 Hz，PF = 1） 校准 – 电学量 用校准器直接产生 33 mV 至 1 V；3,3 mA 至 9 mA 0,1 mW 至 54 kW CMC 0,40 % 33 mV 至 1 V；9 mA 至 33 mA 0,1 mW 至 54 kW CMC 0,25 % 33 mV 至 1 V；33 mA 至 90 mA 0,1 mW 至 54 kW CMC 0,35 % 33 mV 至 1 V；90 mA 至 100 mA 0,1 mW 至 54 kW CMC 0,25 % 1 V 至 5 V；100 mA 至 0,3 A 0,1 mW 至 54 kW CMC 0,20 % 1 V 至 5 V；0,3 A 至 90 A 0,1 mW 至 54 kW CMC 0,18 % 5 V 至 10 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,15 % 5 V 至 10 V；0,3 A 至 0,7 A 0,1 mW 至 54 kW CMC 0,11 % 5 V 至 10 V；0,7 A 至 1 A 0,1 mW 至 54 kW CMC 0,09 % 5 V 至 10 V；1 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 10 V 至 30 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,16 % 10 V 至 30 V；0,3 A 至 10 A 0,1 mW 至 54 kW CMC 0,11 % 10 V 至 30 V；10 A 至 90 A 0,1 mW 至 54 kW CMC 0,13 % 30 V 至 50 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,16 % 30 V 至 50 V；0,3 A 至 0,9 A 0,1 mW 至 54 kW CMC 0,11 % 30 V 至 50 V；0,9 A 至 1 A 0,1 mW 至 54 kW CMC 0,09 % 30 V 至 50 V；1 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 50 V 至 70 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,15 % 50 V 至 70 V；0,3 A 至 0,7 A 0,1 mW 至 54 kW CMC 0,10 % 50 V 至 70 V；0,7 A 至 1 A 0,1 mW 至 54 kW CMC 0,09 % 50 V 至 70 V；1 A 至 10 A 0,1 mW 至 54 kW CMC 0,10 % 50 V 至 70 V；10 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 70 V 至 100 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,15 % 70 V 至 100 V；0,3 A 至 0,7 A 0,1 mW 至 54 kW CMC 0,11 % 70 V 至 100 V；0,7 A 至 1 A 0,1 mW 至 54 kW CMC 0,09 % 70 V 至 100 V；1 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 100 V 至 140 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,15 % 100 V 至 140 V；0,3 A 至 1 A 0,1 mW 至 54 kW CMC 0,09 % 100 V 至 140 V；1 A 至 10 A 0,1 mW 至 54 kW CMC 0,10 % 100 V 至 140 V；10 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 140 V 至 200 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,19 % 140 V 至 200 V；0,3 A 至 0,7 A 0,1 mW 至 54 kW CMC 0,11 % 140 V 至 200 V；0,7 A 至 1 A 0,1 mW 至 54 kW CMC 0,09 % 140 V 至 200 V；1 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 200 V 至 280 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,15 % 200 V 至 280 V；0,3 A 至 0,7 A 0,1 mW 至 54 kW CMC 0,10 % 200 V 至 280 V；0,7 A 至 1 A 0,1 mW 至 54 kW CMC 0,09 % 200 V 至 280 V；1 A 至 10 A 0,1 mW 至 54 kW CMC 0,10 % 200 V 至 280 V；10 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 280 V 至 400 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,16 % 280 V 至 400 V；0,3 A 至 0,5 A 0,1 mW 至 54 kW CMC 0,11 % 280 V 至 400 V；0,5 A 至 5 A 0,1 mW 至 54 kW CMC 0,10 % 280 V 至 400 V；5 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 400 V 至 600 V；0,1 A 至 0,3 A 0,1 mW 至 54 kW CMC 0,15 % 400 V 至 600 V；0,3 A 至 0,5 A 0,1 mW 至 54 kW CMC 0,11 % 400 V 至 600 V；0,5 A 至 10 A 0,1 mW 至 54 kW CMC 0,10 % 400 V 至 600 V；10 A 至 90 A 0,1 mW 至 54 kW CMC 0,12 % 600 V 至 1000 V；100 mA 至 330 mA 0,1 mW 至 54 kW CMC 0,15 % 600 V 至 1000 V；0,33 A 至 0,9 A 0,1 mW 至 54 kW CMC 0,25 % 600 V 至 1000 V；0,9 A 至 2,2 A 0,1 mW 至 54 kW CMC 0,15 % 600 V 至 1000 V；2,2 A 至 4,5 A 0,1 mW 至 54 kW CMC 0,20 % 600 V 至 1000 V；4,5 A 至 11 A 0,1 mW 至 54 kW CMC 0,15 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b55c4342da68d2c90ed1b75","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"18","test_object":"Moc czynna prądu przemiennego, jedno- i trójfazowa / Watomierze prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 0,5 indukcyjny i pojemnościowy)","test_object_en":"AC active power, single-phase and three-phase / AC wattmeters, single-phase and three-phase (f: 45 Hz to 65 Hz, PF = 0,5 inductive and capacitive)","test_object_zh":"单相和三相交流有功功率 / 单相和三相交流功率计（f：45 Hz 至 65 Hz，PF = 0,5 感性和容性）","test_object_cs":"Střídavý činný výkon, jednofázový i třífázový / Střídavé wattmetry jednofázové i třífázové (f: 45 Hz až 65 Hz, PF = 0,5 induktivní a kapacitní)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"330 mV do 1 V; 3,3 mA do 9 mA","range":"od 0,545 mW do 27 kW","cmc":"0,55 %"},{"name":"330 mV do 1 V; 9 mA do 33 mA","range":"od 0,545 mW do 27 kW","cmc":"0,50 %"},{"name":"330 mV do 1 V; 33 mA do 90 mA","range":"od 0,545 mW do 27 kW","cmc":"0,55 %"},{"name":"330 mV do 1 V; 90 mA do 100 mA","range":"od 0,545 mW do 27 kW","cmc":"0,50 %"},{"name":"1 V do 5 V; 100 mA do 0,3 A","range":"od 0,545 mW do 27 kW","cmc":"0,20 %"},{"name":"1 V do 5 V; 0,3 A do 10 A","range":"od 0,545 mW do 27 kW","cmc":"0,17 %"},{"name":"1 V do 5 V; 10 A do 90 A","range":"od 0,545 mW do 27 kW","cmc":"0,25 %"},{"name":"5 V do 600 V; 0,1 A do 0,3 A","range":"od 0,545 mW do 27 kW","cmc":"0,16 %"},{"name":"5 V do 600 V; 0,3 A do 10 A","range":"od 0,545 mW do 27 kW","cmc":"0,12 %"},{"name":"5 V do 600 V; 10 A do 90 A","range":"od 0,545 mW do 27 kW","cmc":"0,22 %"},{"name":"600 V do 1000 V; 100 mA do 330 mA","range":"od 0,545 mW do 27 kW","cmc":"0,50 %"},{"name":"600 V do 1000 V; 0,33 A do 0,9 A","range":"od 0,545 mW do 27 kW","cmc":"0,55 %"},{"name":"600 V do 1000 V; 0,9 A do 2,2 A","range":"od 0,545 mW do 27 kW","cmc":"0,50 %"},{"name":"600 V do 1000 V; 2,2 A do 4,5 A","range":"od 0,545 mW do 27 kW","cmc":"0,55 %"},{"name":"600 V do 1000 V; 4,5 A do 11 A","range":"od 0,545 mW do 27 kW","cmc":"0,50 %"}],"parameters_en":[{"name":"330 mV to 1 V; 3,3 mA to 9 mA","range":"0,545 mW to 27 kW","cmc":"0,55 %"},{"name":"330 mV to 1 V; 9 mA to 33 mA","range":"0,545 mW to 27 kW","cmc":"0,50 %"},{"name":"330 mV to 1 V; 33 mA to 90 mA","range":"0,545 mW to 27 kW","cmc":"0,55 %"},{"name":"330 mV to 1 V; 90 mA to 100 mA","range":"0,545 mW to 27 kW","cmc":"0,50 %"},{"name":"1 V to 5 V; 100 mA to 0,3 A","range":"0,545 mW to 27 kW","cmc":"0,20 %"},{"name":"1 V to 5 V; 0,3 A to 10 A","range":"0,545 mW to 27 kW","cmc":"0,17 %"},{"name":"1 V to 5 V; 10 A to 90 A","range":"0,545 mW to 27 kW","cmc":"0,25 %"},{"name":"5 V to 600 V; 0,1 A to 0,3 A","range":"0,545 mW to 27 kW","cmc":"0,16 %"},{"name":"5 V to 600 V; 0,3 A to 10 A","range":"0,545 mW to 27 kW","cmc":"0,12 %"},{"name":"5 V to 600 V; 10 A to 90 A","range":"0,545 mW to 27 kW","cmc":"0,22 %"},{"name":"600 V to 1000 V; 100 mA to 330 mA","range":"0,545 mW to 27 kW","cmc":"0,50 %"},{"name":"600 V to 1000 V; 0,33 A to 0,9 A","range":"0,545 mW to 27 kW","cmc":"0,55 %"},{"name":"600 V to 1000 V; 0,9 A to 2,2 A","range":"0,545 mW to 27 kW","cmc":"0,50 %"},{"name":"600 V to 1000 V; 2,2 A to 4,5 A","range":"0,545 mW to 27 kW","cmc":"0,55 %"},{"name":"600 V to 1000 V; 4,5 A to 11 A","range":"0,545 mW to 27 kW","cmc":"0,50 %"}],"parameters_zh":[{"name":"330 mV 至 1 V；3,3 mA 至 9 mA","range":"0,545 mW 至 27 kW","cmc":"0,55 %"},{"name":"330 mV 至 1 V；9 mA 至 33 mA","range":"0,545 mW 至 27 kW","cmc":"0,50 %"},{"name":"330 mV 至 1 V；33 mA 至 90 mA","range":"0,545 mW 至 27 kW","cmc":"0,55 %"},{"name":"330 mV 至 1 V；90 mA 至 100 mA","range":"0,545 mW 至 27 kW","cmc":"0,50 %"},{"name":"1 V 至 5 V；100 mA 至 0,3 A","range":"0,545 mW 至 27 kW","cmc":"0,20 %"},{"name":"1 V 至 5 V；0,3 A 至 10 A","range":"0,545 mW 至 27 kW","cmc":"0,17 %"},{"name":"1 V 至 5 V；10 A 至 90 A","range":"0,545 mW 至 27 kW","cmc":"0,25 %"},{"name":"5 V 至 600 V；0,1 A 至 0,3 A","range":"0,545 mW 至 27 kW","cmc":"0,16 %"},{"name":"5 V 至 600 V；0,3 A 至 10 A","range":"0,545 mW 至 27 kW","cmc":"0,12 %"},{"name":"5 V 至 600 V；10 A 至 90 A","range":"0,545 mW 至 27 kW","cmc":"0,22 %"},{"name":"600 V 至 1000 V；100 mA 至 330 mA","range":"0,545 mW 至 27 kW","cmc":"0,50 %"},{"name":"600 V 至 1000 V；0,33 A 至 0,9 A","range":"0,545 mW 至 27 kW","cmc":"0,55 %"},{"name":"600 V 至 1000 V；0,9 A 至 2,2 A","range":"0,545 mW 至 27 kW","cmc":"0,50 %"},{"name":"600 V 至 1000 V；2,2 A 至 4,5 A","range":"0,545 mW 至 27 kW","cmc":"0,55 %"},{"name":"600 V 至 1000 V；4,5 A 至 11 A","range":"0,545 mW 至 27 kW","cmc":"0,50 %"}],"parameters_cs":[{"name":"330 mV až 1 V; 3,3 mA až 9 mA","range":"0,545 mW až 27 kW","cmc":"0,55 %"},{"name":"330 mV až 1 V; 9 mA až 33 mA","range":"0,545 mW až 27 kW","cmc":"0,50 %"},{"name":"330 mV až 1 V; 33 mA až 90 mA","range":"0,545 mW až 27 kW","cmc":"0,55 %"},{"name":"330 mV až 1 V; 90 mA až 100 mA","range":"0,545 mW až 27 kW","cmc":"0,50 %"},{"name":"1 V až 5 V; 100 mA až 0,3 A","range":"0,545 mW až 27 kW","cmc":"0,20 %"},{"name":"1 V až 5 V; 0,3 A až 10 A","range":"0,545 mW až 27 kW","cmc":"0,17 %"},{"name":"1 V až 5 V; 10 A až 90 A","range":"0,545 mW až 27 kW","cmc":"0,25 %"},{"name":"5 V až 600 V; 0,1 A až 0,3 A","range":"0,545 mW až 27 kW","cmc":"0,16 %"},{"name":"5 V až 600 V; 0,3 A až 10 A","range":"0,545 mW až 27 kW","cmc":"0,12 %"},{"name":"5 V až 600 V; 10 A až 90 A","range":"0,545 mW až 27 kW","cmc":"0,22 %"},{"name":"600 V až 1000 V; 100 mA až 330 mA","range":"0,545 mW až 27 kW","cmc":"0,50 %"},{"name":"600 V až 1000 V; 0,33 A až 0,9 A","range":"0,545 mW až 27 kW","cmc":"0,55 %"},{"name":"600 V až 1000 V; 0,9 A až 2,2 A","range":"0,545 mW až 27 kW","cmc":"0,50 %"},{"name":"600 V až 1000 V; 2,2 A až 4,5 A","range":"0,545 mW až 27 kW","cmc":"0,55 %"},{"name":"600 V až 1000 V; 4,5 A až 11 A","range":"0,545 mW až 27 kW","cmc":"0,50 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n330 mV do 1 V; 3,3 mA do 9 mA od 0,545 mW do 27 kW CMC 0,55 %\n330 mV do 1 V; 9 mA do 33 mA od 0,545 mW do 27 kW CMC 0,50 %\n330 mV do 1 V; 33 mA do 90 mA od 0,545 mW do 27 kW CMC 0,55 %\n330 mV do 1 V; 90 mA do 100 mA od 0,545 mW do 27 kW CMC 0,50 %\n1 V do 5 V; 100 mA do 0,3 A od 0,545 mW do 27 kW CMC 0,20 %\n1 V do 5 V; 0,3 A do 10 A od 0,545 mW do 27 kW CMC 0,17 %\n1 V do 5 V; 10 A do 90 A od 0,545 mW do 27 kW CMC 0,25 %\n5 V do 600 V; 0,1 A do 0,3 A od 0,545 mW do 27 kW CMC 0,16 %\n5 V do 600 V; 0,3 A do 10 A od 0,545 mW do 27 kW CMC 0,12 %\n5 V do 600 V; 10 A do 90 A od 0,545 mW do 27 kW CMC 0,22 %\n600 V do 1000 V; 100 mA do 330 mA od 0,545 mW do 27 kW CMC 0,50 %\n600 V do 1000 V; 0,33 A do 0,9 A od 0,545 mW do 27 kW CMC 0,55 %\n600 V do 1000 V; 0,9 A do 2,2 A od 0,545 mW do 27 kW CMC 0,50 %\n600 V do 1000 V; 2,2 A do 4,5 A od 0,545 mW do 27 kW CMC 0,55 %\n600 V do 1000 V; 4,5 A do 11 A od 0,545 mW do 27 kW CMC 0,50 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego, jedno- i trójfazowa / Watomierze prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 0,5 indukcyjny i pojemnościowy) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 330 mV do 1 V; 3,3 mA do 9 mA od 0,545 mW do 27 kW CMC 0,55 % 330 mV do 1 V; 9 mA do 33 mA od 0,545 mW do 27 kW CMC 0,50 % 330 mV do 1 V; 33 mA do 90 mA od 0,545 mW do 27 kW CMC 0,55 % 330 mV do 1 V; 90 mA do 100 mA od 0,545 mW do 27 kW CMC 0,50 % 1 V do 5 V; 100 mA do 0,3 A od 0,545 mW do 27 kW CMC 0,20 % 1 V do 5 V; 0,3 A do 10 A od 0,545 mW do 27 kW CMC 0,17 % 1 V do 5 V; 10 A do 90 A od 0,545 mW do 27 kW CMC 0,25 % 5 V do 600 V; 0,1 A do 0,3 A od 0,545 mW do 27 kW CMC 0,16 % 5 V do 600 V; 0,3 A do 10 A od 0,545 mW do 27 kW CMC 0,12 % 5 V do 600 V; 10 A do 90 A od 0,545 mW do 27 kW CMC 0,22 % 600 V do 1000 V; 100 mA do 330 mA od 0,545 mW do 27 kW CMC 0,50 % 600 V do 1000 V; 0,33 A do 0,9 A od 0,545 mW do 27 kW CMC 0,55 % 600 V do 1000 V; 0,9 A do 2,2 A od 0,545 mW do 27 kW CMC 0,50 % 600 V do 1000 V; 2,2 A do 4,5 A od 0,545 mW do 27 kW CMC 0,55 % 600 V do 1000 V; 4,5 A do 11 A od 0,545 mW do 27 kW CMC 0,50 % Střídavý činný výkon, jednofázový i třífázový / Střídavé wattmetry jednofázové i třífázové (f: 45 Hz až 65 Hz, PF = 0,5 induktivní a kapacitní) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 330 mV až 1 V; 3,3 mA až 9 mA 0,545 mW až 27 kW CMC 0,55 % 330 mV až 1 V; 9 mA až 33 mA 0,545 mW až 27 kW CMC 0,50 % 330 mV až 1 V; 33 mA až 90 mA 0,545 mW až 27 kW CMC 0,55 % 330 mV až 1 V; 90 mA až 100 mA 0,545 mW až 27 kW CMC 0,50 % 1 V až 5 V; 100 mA až 0,3 A 0,545 mW až 27 kW CMC 0,20 % 1 V až 5 V; 0,3 A až 10 A 0,545 mW až 27 kW CMC 0,17 % 1 V až 5 V; 10 A až 90 A 0,545 mW až 27 kW CMC 0,25 % 5 V až 600 V; 0,1 A až 0,3 A 0,545 mW až 27 kW CMC 0,16 % 5 V až 600 V; 0,3 A až 10 A 0,545 mW až 27 kW CMC 0,12 % 5 V až 600 V; 10 A až 90 A 0,545 mW až 27 kW CMC 0,22 % 600 V až 1000 V; 100 mA až 330 mA 0,545 mW až 27 kW CMC 0,50 % 600 V až 1000 V; 0,33 A až 0,9 A 0,545 mW až 27 kW CMC 0,55 % 600 V až 1000 V; 0,9 A až 2,2 A 0,545 mW až 27 kW CMC 0,50 % 600 V až 1000 V; 2,2 A až 4,5 A 0,545 mW až 27 kW CMC 0,55 % 600 V až 1000 V; 4,5 A až 11 A 0,545 mW až 27 kW CMC 0,50 % TP16 Moc czynna pradu przemiennego, jedno- i trojfazowa / Watomierze pradu przemiennego jedno- i trojfazowe (f: 45 Hz do 65 Hz, PF = 0,5 indukcyjny i pojemnosciowy) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 330 mV do 1 V; 3,3 mA do 9 mA od 0,545 mW do 27 kW CMC 0,55 % 330 mV do 1 V; 9 mA do 33 mA od 0,545 mW do 27 kW CMC 0,50 % 330 mV do 1 V; 33 mA do 90 mA od 0,545 mW do 27 kW CMC 0,55 % 330 mV do 1 V; 90 mA do 100 mA od 0,545 mW do 27 kW CMC 0,50 % 1 V do 5 V; 100 mA do 0,3 A od 0,545 mW do 27 kW CMC 0,20 % 1 V do 5 V; 0,3 A do 10 A od 0,545 mW do 27 kW CMC 0,17 % 1 V do 5 V; 10 A do 90 A od 0,545 mW do 27 kW CMC 0,25 % 5 V do 600 V; 0,1 A do 0,3 A od 0,545 mW do 27 kW CMC 0,16 % 5 V do 600 V; 0,3 A do 10 A od 0,545 mW do 27 kW CMC 0,12 % 5 V do 600 V; 10 A do 90 A od 0,545 mW do 27 kW CMC 0,22 % 600 V do 1000 V; 100 mA do 330 mA od 0,545 mW do 27 kW CMC 0,50 % 600 V do 1000 V; 0,33 A do 0,9 A od 0,545 mW do 27 kW CMC 0,55 % 600 V do 1000 V; 0,9 A do 2,2 A od 0,545 mW do 27 kW CMC 0,50 % 600 V do 1000 V; 2,2 A do 4,5 A od 0,545 mW do 27 kW CMC 0,55 % 600 V do 1000 V; 4,5 A do 11 A od 0,545 mW do 27 kW CMC 0,50 % Stridavy cinny vykon, jednofazovy i trifazovy / Stridave wattmetry jednofazove i trifazove (f: 45 Hz az 65 Hz, PF = 0,5 induktivni a kapacitni) Kalibrace – elektricke veliciny Prime generovani kalibratorem 330 mV az 1 V; 3,3 mA az 9 mA 0,545 mW az 27 kW CMC 0,55 % 330 mV az 1 V; 9 mA az 33 mA 0,545 mW az 27 kW CMC 0,50 % 330 mV az 1 V; 33 mA az 90 mA 0,545 mW az 27 kW CMC 0,55 % 330 mV az 1 V; 90 mA az 100 mA 0,545 mW az 27 kW CMC 0,50 % 1 V az 5 V; 100 mA az 0,3 A 0,545 mW az 27 kW CMC 0,20 % 1 V az 5 V; 0,3 A az 10 A 0,545 mW az 27 kW CMC 0,17 % 1 V az 5 V; 10 A az 90 A 0,545 mW az 27 kW CMC 0,25 % 5 V az 600 V; 0,1 A az 0,3 A 0,545 mW az 27 kW CMC 0,16 % 5 V az 600 V; 0,3 A az 10 A 0,545 mW az 27 kW CMC 0,12 % 5 V az 600 V; 10 A az 90 A 0,545 mW az 27 kW CMC 0,22 % 600 V az 1000 V; 100 mA az 330 mA 0,545 mW az 27 kW CMC 0,50 % 600 V az 1000 V; 0,33 A az 0,9 A 0,545 mW az 27 kW CMC 0,55 % 600 V az 1000 V; 0,9 A az 2,2 A 0,545 mW az 27 kW CMC 0,50 % 600 V az 1000 V; 2,2 A az 4,5 A 0,545 mW az 27 kW CMC 0,55 % 600 V az 1000 V; 4,5 A az 11 A 0,545 mW az 27 kW CMC 0,50 % TP16","search_en":"AC active power, single-phase and three-phase / AC wattmeters, single-phase and three-phase (f: 45 Hz to 65 Hz, PF = 0,5 inductive and capacitive) Calibration – electrical quantities Direct generation with a calibrator 330 mV to 1 V; 3,3 mA to 9 mA 0,545 mW to 27 kW CMC 0,55 % 330 mV to 1 V; 9 mA to 33 mA 0,545 mW to 27 kW CMC 0,50 % 330 mV to 1 V; 33 mA to 90 mA 0,545 mW to 27 kW CMC 0,55 % 330 mV to 1 V; 90 mA to 100 mA 0,545 mW to 27 kW CMC 0,50 % 1 V to 5 V; 100 mA to 0,3 A 0,545 mW to 27 kW CMC 0,20 % 1 V to 5 V; 0,3 A to 10 A 0,545 mW to 27 kW CMC 0,17 % 1 V to 5 V; 10 A to 90 A 0,545 mW to 27 kW CMC 0,25 % 5 V to 600 V; 0,1 A to 0,3 A 0,545 mW to 27 kW CMC 0,16 % 5 V to 600 V; 0,3 A to 10 A 0,545 mW to 27 kW CMC 0,12 % 5 V to 600 V; 10 A to 90 A 0,545 mW to 27 kW CMC 0,22 % 600 V to 1000 V; 100 mA to 330 mA 0,545 mW to 27 kW CMC 0,50 % 600 V to 1000 V; 0,33 A to 0,9 A 0,545 mW to 27 kW CMC 0,55 % 600 V to 1000 V; 0,9 A to 2,2 A 0,545 mW to 27 kW CMC 0,50 % 600 V to 1000 V; 2,2 A to 4,5 A 0,545 mW to 27 kW CMC 0,55 % 600 V to 1000 V; 4,5 A to 11 A 0,545 mW to 27 kW CMC 0,50 % TP16","search_zh":"单相和三相交流有功功率 / 单相和三相交流功率计（f：45 Hz 至 65 Hz，PF = 0,5 感性和容性） 校准 – 电学量 用校准器直接产生 330 mV 至 1 V；3,3 mA 至 9 mA 0,545 mW 至 27 kW CMC 0,55 % 330 mV 至 1 V；9 mA 至 33 mA 0,545 mW 至 27 kW CMC 0,50 % 330 mV 至 1 V；33 mA 至 90 mA 0,545 mW 至 27 kW CMC 0,55 % 330 mV 至 1 V；90 mA 至 100 mA 0,545 mW 至 27 kW CMC 0,50 % 1 V 至 5 V；100 mA 至 0,3 A 0,545 mW 至 27 kW CMC 0,20 % 1 V 至 5 V；0,3 A 至 10 A 0,545 mW 至 27 kW CMC 0,17 % 1 V 至 5 V；10 A 至 90 A 0,545 mW 至 27 kW CMC 0,25 % 5 V 至 600 V；0,1 A 至 0,3 A 0,545 mW 至 27 kW CMC 0,16 % 5 V 至 600 V；0,3 A 至 10 A 0,545 mW 至 27 kW CMC 0,12 % 5 V 至 600 V；10 A 至 90 A 0,545 mW 至 27 kW CMC 0,22 % 600 V 至 1000 V；100 mA 至 330 mA 0,545 mW 至 27 kW CMC 0,50 % 600 V 至 1000 V；0,33 A 至 0,9 A 0,545 mW 至 27 kW CMC 0,55 % 600 V 至 1000 V；0,9 A 至 2,2 A 0,545 mW 至 27 kW CMC 0,50 % 600 V 至 1000 V；2,2 A 至 4,5 A 0,545 mW 至 27 kW CMC 0,55 % 600 V 至 1000 V；4,5 A 至 11 A 0,545 mW 至 27 kW CMC 0,50 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c6e6341092dee5f4567445db","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"18","test_object":"Moc czynna prądu przemiennego, jednofazowa / Watomierze prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 1)","test_object_en":"AC active power, single-phase / AC wattmeters, single-phase (f: 65 Hz to 500 Hz, PF = 1)","test_object_zh":"单相交流有功功率 / 单相交流功率计（f：65 Hz 至 500 Hz，PF = 1）","test_object_cs":"Střídavý činný výkon, jednofázový / Střídavé wattmetry jednofázové (f: 65 Hz až 500 Hz, PF = 1)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"330 mV do 1000 V; 3,3 mA do 9 mA","range":"od 1,089 mW do 11 kW","cmc":"0,26 %"},{"name":"330 mV do 1000 V; 9 mA do 33 mA","range":"od 1,089 mW do 11 kW","cmc":"0,16 %"},{"name":"330 mV do 1000 V; 33 mA do 90 mA","range":"od 1,089 mW do 11 kW","cmc":"0,26 %"},{"name":"330 mV do 1000 V; 90 mA do 330 mA","range":"od 1,089 mW do 11 kW","cmc":"0,16 %"},{"name":"330 mV do 1000 V; 0,33 A do 0,9 A","range":"od 1,089 mW do 11 kW","cmc":"0,26 %"},{"name":"330 mV do 1000 V; 0,9 A do 2,2 A","range":"od 1,089 mW do 11 kW","cmc":"0,16 %"},{"name":"330 mV do 1000 V; 2,2 A do 4,5 A","range":"od 1,089 mW do 11 kW","cmc":"0,21 %"},{"name":"330 mV do 1000 V; 4,5 A do 11 A","range":"od 1,089 mW do 11 kW","cmc":"0,16 %"}],"parameters_en":[{"name":"330 mV to 1000 V; 3,3 mA to 9 mA","range":"1,089 mW to 11 kW","cmc":"0,26 %"},{"name":"330 mV to 1000 V; 9 mA to 33 mA","range":"1,089 mW to 11 kW","cmc":"0,16 %"},{"name":"330 mV to 1000 V; 33 mA to 90 mA","range":"1,089 mW to 11 kW","cmc":"0,26 %"},{"name":"330 mV to 1000 V; 90 mA to 330 mA","range":"1,089 mW to 11 kW","cmc":"0,16 %"},{"name":"330 mV to 1000 V; 0,33 A to 0,9 A","range":"1,089 mW to 11 kW","cmc":"0,26 %"},{"name":"330 mV to 1000 V; 0,9 A to 2,2 A","range":"1,089 mW to 11 kW","cmc":"0,16 %"},{"name":"330 mV to 1000 V; 2,2 A to 4,5 A","range":"1,089 mW to 11 kW","cmc":"0,21 %"},{"name":"330 mV to 1000 V; 4,5 A to 11 A","range":"1,089 mW to 11 kW","cmc":"0,16 %"}],"parameters_zh":[{"name":"330 mV 至 1000 V；3,3 mA 至 9 mA","range":"1,089 mW 至 11 kW","cmc":"0,26 %"},{"name":"330 mV 至 1000 V；9 mA 至 33 mA","range":"1,089 mW 至 11 kW","cmc":"0,16 %"},{"name":"330 mV 至 1000 V；33 mA 至 90 mA","range":"1,089 mW 至 11 kW","cmc":"0,26 %"},{"name":"330 mV 至 1000 V；90 mA 至 330 mA","range":"1,089 mW 至 11 kW","cmc":"0,16 %"},{"name":"330 mV 至 1000 V；0,33 A 至 0,9 A","range":"1,089 mW 至 11 kW","cmc":"0,26 %"},{"name":"330 mV 至 1000 V；0,9 A 至 2,2 A","range":"1,089 mW 至 11 kW","cmc":"0,16 %"},{"name":"330 mV 至 1000 V；2,2 A 至 4,5 A","range":"1,089 mW 至 11 kW","cmc":"0,21 %"},{"name":"330 mV 至 1000 V；4,5 A 至 11 A","range":"1,089 mW 至 11 kW","cmc":"0,16 %"}],"parameters_cs":[{"name":"330 mV až 1000 V; 3,3 mA až 9 mA","range":"1,089 mW až 11 kW","cmc":"0,26 %"},{"name":"330 mV až 1000 V; 9 mA až 33 mA","range":"1,089 mW až 11 kW","cmc":"0,16 %"},{"name":"330 mV až 1000 V; 33 mA až 90 mA","range":"1,089 mW až 11 kW","cmc":"0,26 %"},{"name":"330 mV až 1000 V; 90 mA až 330 mA","range":"1,089 mW až 11 kW","cmc":"0,16 %"},{"name":"330 mV až 1000 V; 0,33 A až 0,9 A","range":"1,089 mW až 11 kW","cmc":"0,26 %"},{"name":"330 mV až 1000 V; 0,9 A až 2,2 A","range":"1,089 mW až 11 kW","cmc":"0,16 %"},{"name":"330 mV až 1000 V; 2,2 A až 4,5 A","range":"1,089 mW až 11 kW","cmc":"0,21 %"},{"name":"330 mV až 1000 V; 4,5 A až 11 A","range":"1,089 mW až 11 kW","cmc":"0,16 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n330 mV do 1000 V; 3,3 mA do 9 mA od 1,089 mW do 11 kW CMC 0,26 %\n330 mV do 1000 V; 9 mA do 33 mA od 1,089 mW do 11 kW CMC 0,16 %\n330 mV do 1000 V; 33 mA do 90 mA od 1,089 mW do 11 kW CMC 0,26 %\n330 mV do 1000 V; 90 mA do 330 mA od 1,089 mW do 11 kW CMC 0,16 %\n330 mV do 1000 V; 0,33 A do 0,9 A od 1,089 mW do 11 kW CMC 0,26 %\n330 mV do 1000 V; 0,9 A do 2,2 A od 1,089 mW do 11 kW CMC 0,16 %\n330 mV do 1000 V; 2,2 A do 4,5 A od 1,089 mW do 11 kW CMC 0,21 %\n330 mV do 1000 V; 4,5 A do 11 A od 1,089 mW do 11 kW CMC 0,16 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego, jednofazowa / Watomierze prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 1) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 9 mA od 1,089 mW do 11 kW CMC 0,26 % 330 mV do 1000 V; 9 mA do 33 mA od 1,089 mW do 11 kW CMC 0,16 % 330 mV do 1000 V; 33 mA do 90 mA od 1,089 mW do 11 kW CMC 0,26 % 330 mV do 1000 V; 90 mA do 330 mA od 1,089 mW do 11 kW CMC 0,16 % 330 mV do 1000 V; 0,33 A do 0,9 A od 1,089 mW do 11 kW CMC 0,26 % 330 mV do 1000 V; 0,9 A do 2,2 A od 1,089 mW do 11 kW CMC 0,16 % 330 mV do 1000 V; 2,2 A do 4,5 A od 1,089 mW do 11 kW CMC 0,21 % 330 mV do 1000 V; 4,5 A do 11 A od 1,089 mW do 11 kW CMC 0,16 % Střídavý činný výkon, jednofázový / Střídavé wattmetry jednofázové (f: 65 Hz až 500 Hz, PF = 1) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 330 mV až 1000 V; 3,3 mA až 9 mA 1,089 mW až 11 kW CMC 0,26 % 330 mV až 1000 V; 9 mA až 33 mA 1,089 mW až 11 kW CMC 0,16 % 330 mV až 1000 V; 33 mA až 90 mA 1,089 mW až 11 kW CMC 0,26 % 330 mV až 1000 V; 90 mA až 330 mA 1,089 mW až 11 kW CMC 0,16 % 330 mV až 1000 V; 0,33 A až 0,9 A 1,089 mW až 11 kW CMC 0,26 % 330 mV až 1000 V; 0,9 A až 2,2 A 1,089 mW až 11 kW CMC 0,16 % 330 mV až 1000 V; 2,2 A až 4,5 A 1,089 mW až 11 kW CMC 0,21 % 330 mV až 1000 V; 4,5 A až 11 A 1,089 mW až 11 kW CMC 0,16 % TP16 Moc czynna pradu przemiennego, jednofazowa / Watomierze pradu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 1) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 9 mA od 1,089 mW do 11 kW CMC 0,26 % 330 mV do 1000 V; 9 mA do 33 mA od 1,089 mW do 11 kW CMC 0,16 % 330 mV do 1000 V; 33 mA do 90 mA od 1,089 mW do 11 kW CMC 0,26 % 330 mV do 1000 V; 90 mA do 330 mA od 1,089 mW do 11 kW CMC 0,16 % 330 mV do 1000 V; 0,33 A do 0,9 A od 1,089 mW do 11 kW CMC 0,26 % 330 mV do 1000 V; 0,9 A do 2,2 A od 1,089 mW do 11 kW CMC 0,16 % 330 mV do 1000 V; 2,2 A do 4,5 A od 1,089 mW do 11 kW CMC 0,21 % 330 mV do 1000 V; 4,5 A do 11 A od 1,089 mW do 11 kW CMC 0,16 % Stridavy cinny vykon, jednofazovy / Stridave wattmetry jednofazove (f: 65 Hz az 500 Hz, PF = 1) Kalibrace – elektricke veliciny Prime generovani kalibratorem 330 mV az 1000 V; 3,3 mA az 9 mA 1,089 mW az 11 kW CMC 0,26 % 330 mV az 1000 V; 9 mA az 33 mA 1,089 mW az 11 kW CMC 0,16 % 330 mV az 1000 V; 33 mA az 90 mA 1,089 mW az 11 kW CMC 0,26 % 330 mV az 1000 V; 90 mA az 330 mA 1,089 mW az 11 kW CMC 0,16 % 330 mV az 1000 V; 0,33 A az 0,9 A 1,089 mW az 11 kW CMC 0,26 % 330 mV az 1000 V; 0,9 A az 2,2 A 1,089 mW az 11 kW CMC 0,16 % 330 mV az 1000 V; 2,2 A az 4,5 A 1,089 mW az 11 kW CMC 0,21 % 330 mV az 1000 V; 4,5 A az 11 A 1,089 mW az 11 kW CMC 0,16 % TP16","search_en":"AC active power, single-phase / AC wattmeters, single-phase (f: 65 Hz to 500 Hz, PF = 1) Calibration – electrical quantities Direct generation with a calibrator 330 mV to 1000 V; 3,3 mA to 9 mA 1,089 mW to 11 kW CMC 0,26 % 330 mV to 1000 V; 9 mA to 33 mA 1,089 mW to 11 kW CMC 0,16 % 330 mV to 1000 V; 33 mA to 90 mA 1,089 mW to 11 kW CMC 0,26 % 330 mV to 1000 V; 90 mA to 330 mA 1,089 mW to 11 kW CMC 0,16 % 330 mV to 1000 V; 0,33 A to 0,9 A 1,089 mW to 11 kW CMC 0,26 % 330 mV to 1000 V; 0,9 A to 2,2 A 1,089 mW to 11 kW CMC 0,16 % 330 mV to 1000 V; 2,2 A to 4,5 A 1,089 mW to 11 kW CMC 0,21 % 330 mV to 1000 V; 4,5 A to 11 A 1,089 mW to 11 kW CMC 0,16 % TP16","search_zh":"单相交流有功功率 / 单相交流功率计（f：65 Hz 至 500 Hz，PF = 1） 校准 – 电学量 用校准器直接产生 330 mV 至 1000 V；3,3 mA 至 9 mA 1,089 mW 至 11 kW CMC 0,26 % 330 mV 至 1000 V；9 mA 至 33 mA 1,089 mW 至 11 kW CMC 0,16 % 330 mV 至 1000 V；33 mA 至 90 mA 1,089 mW 至 11 kW CMC 0,26 % 330 mV 至 1000 V；90 mA 至 330 mA 1,089 mW 至 11 kW CMC 0,16 % 330 mV 至 1000 V；0,33 A 至 0,9 A 1,089 mW 至 11 kW CMC 0,26 % 330 mV 至 1000 V；0,9 A 至 2,2 A 1,089 mW 至 11 kW CMC 0,16 % 330 mV 至 1000 V；2,2 A 至 4,5 A 1,089 mW 至 11 kW CMC 0,21 % 330 mV 至 1000 V；4,5 A 至 11 A 1,089 mW 至 11 kW CMC 0,16 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"298dc5561ac70de6eea620f8","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"18","test_object":"Moc czynna prądu przemiennego, jednofazowa / Watomierze prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 0,5 indukcyjny i pojemnościowy)","test_object_en":"AC active power, single-phase / AC wattmeters, single-phase (f: 65 Hz to 500 Hz, PF = 0,5 inductive and capacitive)","test_object_zh":"单相交流有功功率 / 单相交流功率计（f：65 Hz 至 500 Hz，PF = 0,5 感性和容性）","test_object_cs":"Střídavý činný výkon, jednofázový / Střídavé wattmetry jednofázové (f: 65 Hz až 500 Hz, PF = 0,5 induktivní a kapacitní)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"330 mV do 1000 V; 3,3 mA do 11 A","range":"od 0,545 mW do 5,5 kW","cmc":"2,8 %"}],"parameters_en":[{"name":"330 mV to 1000 V; 3,3 mA to 11 A","range":"0,545 mW to 5,5 kW","cmc":"2,8 %"}],"parameters_zh":[{"name":"330 mV 至 1000 V；3,3 mA 至 11 A","range":"0,545 mW 至 5,5 kW","cmc":"2,8 %"}],"parameters_cs":[{"name":"330 mV až 1000 V; 3,3 mA až 11 A","range":"0,545 mW až 5,5 kW","cmc":"2,8 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n330 mV do 1000 V; 3,3 mA do 11 A od 0,545 mW do 5,5 kW CMC 2,8 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego, jednofazowa / Watomierze prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 0,5 indukcyjny i pojemnościowy) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 11 A od 0,545 mW do 5,5 kW CMC 2,8 % Střídavý činný výkon, jednofázový / Střídavé wattmetry jednofázové (f: 65 Hz až 500 Hz, PF = 0,5 induktivní a kapacitní) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 330 mV až 1000 V; 3,3 mA až 11 A 0,545 mW až 5,5 kW CMC 2,8 % TP16 Moc czynna pradu przemiennego, jednofazowa / Watomierze pradu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 0,5 indukcyjny i pojemnosciowy) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 11 A od 0,545 mW do 5,5 kW CMC 2,8 % Stridavy cinny vykon, jednofazovy / Stridave wattmetry jednofazove (f: 65 Hz az 500 Hz, PF = 0,5 induktivni a kapacitni) Kalibrace – elektricke veliciny Prime generovani kalibratorem 330 mV az 1000 V; 3,3 mA az 11 A 0,545 mW az 5,5 kW CMC 2,8 % TP16","search_en":"AC active power, single-phase / AC wattmeters, single-phase (f: 65 Hz to 500 Hz, PF = 0,5 inductive and capacitive) Calibration – electrical quantities Direct generation with a calibrator 330 mV to 1000 V; 3,3 mA to 11 A 0,545 mW to 5,5 kW CMC 2,8 % TP16","search_zh":"单相交流有功功率 / 单相交流功率计（f：65 Hz 至 500 Hz，PF = 0,5 感性和容性） 校准 – 电学量 用校准器直接产生 330 mV 至 1000 V；3,3 mA 至 11 A 0,545 mW 至 5,5 kW CMC 2,8 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f62042754ce78a3fbdf95e7b","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"18","test_object":"Moc czynna prądu przemiennego jednofazowa / Watomierze prądu przemiennego jednofazowe z cęgowymi czujnikami prądu (f: 45 Hz do 65 Hz, PF = 1)","test_object_en":"AC active power, single-phase / AC wattmeters, single-phase, with clamp sensors (f: 45 Hz to 65 Hz, PF = 1)","test_object_zh":"单相交流有功功率 / 带钳形电流传感器的单相交流功率计（f：45 Hz 至 65 Hz，PF = 1）","test_object_cs":"Střídavý činný výkon jednofázový / Střídavé wattmetry jednofázové s klešťovými snímači proudu (f: 45 Hz až 65 Hz, PF = 1)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"33 mV do 1000 V; 10 A do 2250 A","range":"od 330 mW do 1,35 MW","cmc":"0,50 %"}],"parameters_en":[{"name":"33 mV to 1000 V; 10 A to 2250 A","range":"330 mW to 1,35 MW","cmc":"0,50 %"}],"parameters_zh":[{"name":"33 mV 至 1000 V；10 A 至 2250 A","range":"330 mW 至 1,35 MW","cmc":"0,50 %"}],"parameters_cs":[{"name":"33 mV až 1000 V; 10 A až 2250 A","range":"330 mW až 1,35 MW","cmc":"0,50 %"}],"technique":"Pośrednie generowanie kalibratorem z cewką prądową","technique_en":"Indirect generation with a calibrator with a current coil","technique_zh":"用带电流线圈的校准器间接产生","technique_cs":"Nepřímé generování kalibrátorem s proudovou cívkou","techniques":["Pośrednie generowanie kalibratorem z cewką prądową"],"techniques_en":["Indirect generation with a calibrator with a current coil"],"techniques_zh":["用带电流线圈的校准器间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n33 mV do 1000 V; 10 A do 2250 A od 330 mW do 1,35 MW CMC 0,50 %\nPośrednie generowanie kalibratorem z cewką prądową","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego jednofazowa / Watomierze prądu przemiennego jednofazowe z cęgowymi czujnikami prądu (f: 45 Hz do 65 Hz, PF = 1) Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z cewką prądową 33 mV do 1000 V; 10 A do 2250 A od 330 mW do 1,35 MW CMC 0,50 % Střídavý činný výkon jednofázový / Střídavé wattmetry jednofázové s klešťovými snímači proudu (f: 45 Hz až 65 Hz, PF = 1) Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem s proudovou cívkou 33 mV až 1000 V; 10 A až 2250 A 330 mW až 1,35 MW CMC 0,50 % TP16 Moc czynna pradu przemiennego jednofazowa / Watomierze pradu przemiennego jednofazowe z cegowymi czujnikami pradu (f: 45 Hz do 65 Hz, PF = 1) Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z cewka pradowa 33 mV do 1000 V; 10 A do 2250 A od 330 mW do 1,35 MW CMC 0,50 % Stridavy cinny vykon jednofazovy / Stridave wattmetry jednofazove s klestovymi snimaci proudu (f: 45 Hz az 65 Hz, PF = 1) Kalibrace – elektricke veliciny Neprime generovani kalibratorem s proudovou civkou 33 mV az 1000 V; 10 A az 2250 A 330 mW az 1,35 MW CMC 0,50 % TP16","search_en":"AC active power, single-phase / AC wattmeters, single-phase, with clamp sensors (f: 45 Hz to 65 Hz, PF = 1) Calibration – electrical quantities Indirect generation with a calibrator with a current coil 33 mV to 1000 V; 10 A to 2250 A 330 mW to 1,35 MW CMC 0,50 % TP16","search_zh":"单相交流有功功率 / 带钳形电流传感器的单相交流功率计（f：45 Hz 至 65 Hz，PF = 1） 校准 – 电学量 用带电流线圈的校准器间接产生 33 mV 至 1000 V；10 A 至 2250 A 330 mW 至 1,35 MW CMC 0,50 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"366bb60ff59803c568b462d4","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"18","test_object":"Moc czynna prądu przemiennego, trójfazowa / Watomierze prądu przemiennego trójfazowe z cęgowymi czujnikami prądu (f: 45 Hz do 65 Hz, PF = 1)","test_object_en":"AC active power, three-phase / AC wattmeters, three-phase, with clamp sensors (f: 45 Hz to 65 Hz, PF = 1)","test_object_zh":"三相交流有功功率 / 带钳形电流传感器的三相交流功率计（f：45 Hz 至 65 Hz，PF = 1）","test_object_cs":"Střídavý činný výkon, třífázový / Střídavé wattmetry třífázové s klešťovými snímači proudu (f: 45 Hz až 65 Hz, PF = 1)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 600 V; 1 A do 1500 A","range":"od 1 W do 900 kW","cmc":"0,50 %"}],"parameters_en":[{"name":"1 V to 600 V; 1 A to 1500 A","range":"1 W to 900 kW","cmc":"0,50 %"}],"parameters_zh":[{"name":"1 V 至 600 V；1 A 至 1500 A","range":"1 W 至 900 kW","cmc":"0,50 %"}],"parameters_cs":[{"name":"1 V až 600 V; 1 A až 1500 A","range":"1 W až 900 kW","cmc":"0,50 %"}],"technique":"Pośrednie generowanie kalibratorem z cewkami prądowymi","technique_en":"Indirect generation with a calibrator with current coils","technique_zh":"用带电流线圈的校准器间接产生","technique_cs":"Nepřímé generování kalibrátorem s proudovými cívkami","techniques":["Pośrednie generowanie kalibratorem z cewkami prądowymi"],"techniques_en":["Indirect generation with a calibrator with current coils"],"techniques_zh":["用带电流线圈的校准器间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem s proudovými cívkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 600 V; 1 A do 1500 A od 1 W do 900 kW CMC 0,50 %\nPośrednie generowanie kalibratorem z cewkami prądowymi","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc czynna prądu przemiennego, trójfazowa / Watomierze prądu przemiennego trójfazowe z cęgowymi czujnikami prądu (f: 45 Hz do 65 Hz, PF = 1) Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z cewkami prądowymi 1 V do 600 V; 1 A do 1500 A od 1 W do 900 kW CMC 0,50 % Střídavý činný výkon, třífázový / Střídavé wattmetry třífázové s klešťovými snímači proudu (f: 45 Hz až 65 Hz, PF = 1) Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem s proudovými cívkami 1 V až 600 V; 1 A až 1500 A 1 W až 900 kW CMC 0,50 % TP16 Moc czynna pradu przemiennego, trojfazowa / Watomierze pradu przemiennego trojfazowe z cegowymi czujnikami pradu (f: 45 Hz do 65 Hz, PF = 1) Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z cewkami pradowymi 1 V do 600 V; 1 A do 1500 A od 1 W do 900 kW CMC 0,50 % Stridavy cinny vykon, trifazovy / Stridave wattmetry trifazove s klestovymi snimaci proudu (f: 45 Hz az 65 Hz, PF = 1) Kalibrace – elektricke veliciny Neprime generovani kalibratorem s proudovymi civkami 1 V az 600 V; 1 A az 1500 A 1 W az 900 kW CMC 0,50 % TP16","search_en":"AC active power, three-phase / AC wattmeters, three-phase, with clamp sensors (f: 45 Hz to 65 Hz, PF = 1) Calibration – electrical quantities Indirect generation with a calibrator with current coils 1 V to 600 V; 1 A to 1500 A 1 W to 900 kW CMC 0,50 % TP16","search_zh":"三相交流有功功率 / 带钳形电流传感器的三相交流功率计（f：45 Hz 至 65 Hz，PF = 1） 校准 – 电学量 用带电流线圈的校准器间接产生 1 V 至 600 V；1 A 至 1500 A 1 W 至 900 kW CMC 0,50 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a8633ac92f1d5f354d80751c","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"19","test_object":"Moc bierna prądu przemiennego, jedno- i trójfazowa / Watomierze prądu przemiennego, jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 0)","test_object_en":"AC reactive power, single- and three-phase / AC wattmeters, single- and three-phase (f: 45 Hz to 65 Hz, PF = 0)","test_object_zh":"单相和三相交流无功功率 / 单相和三相交流功率计（f：45 Hz 至 65 Hz，PF = 0）","test_object_cs":"Střídavý jalový výkon, jednofázový i třífázový / Střídavé wattmetry, jednofázové i třífázové (f: 45 Hz až 65 Hz, PF = 0)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 5 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,20 %"},{"name":"1 V do 5 V; 0,3 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,18 %"},{"name":"5 V do 10 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,15 %"},{"name":"5 V do 10 V; 0,3 A do 0,7 A","range":"od 100 mvar do 54 kvar","cmc":"0,11 %"},{"name":"5 V do 10 V; 0,7 A do 1 A","range":"od 100 mvar do 54 kvar","cmc":"0,09 %"},{"name":"5 V do 10 V; 1 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"10 V do 30 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,16 %"},{"name":"10 V do 30 V; 0,3 A do 10 A","range":"od 100 mvar do 54 kvar","cmc":"0,11 %"},{"name":"10 V do 30 V; 10 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,13 %"},{"name":"30 V do 50 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,16 %"},{"name":"30 V do 50 V; 0,3 A do 0,9 A","range":"od 100 mvar do 54 kvar","cmc":"0,11 %"},{"name":"30 V do 50 V; 0,9 A do 1 A","range":"od 100 mvar do 54 kvar","cmc":"0,09 %"},{"name":"30 V do 50 V; 1 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"50 V do 70 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,15 %"},{"name":"50 V do 70 V; 0,3 A do 0,7 A","range":"od 100 mvar do 54 kvar","cmc":"0,10 %"},{"name":"50 V do 70 V; 0,7 A do 1 A","range":"od 100 mvar do 54 kvar","cmc":"0,09 %"},{"name":"50 V do 70 V; 1 A do 10 A","range":"od 100 mvar do 54 kvar","cmc":"0,10 %"},{"name":"50 V do 70 V; 10 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"70 V do 100 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,15 %"},{"name":"70 V do 100 V; 0,3 A do 0,7 A","range":"od 100 mvar do 54 kvar","cmc":"0,11 %"},{"name":"70 V do 100 V; 0,7 A do 1 A","range":"od 100 mvar do 54 kvar","cmc":"0,09 %"},{"name":"70 V do 100 V; 1 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"100 V do 140 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,15 %"},{"name":"100 V do 140 V; 0,3 A do 1 A","range":"od 100 mvar do 54 kvar","cmc":"0,09 %"},{"name":"100 V do 140 V; 1 A do 10 A","range":"od 100 mvar do 54 kvar","cmc":"0,10 %"},{"name":"100 V do 140 V; 10 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"140 V do 200 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,19 %"},{"name":"140 V do 200 V; 0,3 A do 0,7 A","range":"od 100 mvar do 54 kvar","cmc":"0,11 %"},{"name":"140 V do 200 V; 0,7 A do 1 A","range":"od 100 mvar do 54 kvar","cmc":"0,09 %"},{"name":"140 V do 200 V; 1 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"200 V do 280 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,15 %"},{"name":"200 V do 280 V; 0,3 A do 0,7 A","range":"od 100 mvar do 54 kvar","cmc":"0,10 %"},{"name":"200 V do 280 V; 0,7 A do 1 A","range":"od 100 mvar do 54 kvar","cmc":"0,09 %"},{"name":"200 V do 280 V; 1 A do 10 A","range":"od 100 mvar do 54 kvar","cmc":"0,10 %"},{"name":"200 V do 280 V; 10 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"280 V do 400 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,16 %"},{"name":"280 V do 400 V; 0,3 A do 0,5 A","range":"od 100 mvar do 54 kvar","cmc":"0,11 %"},{"name":"280 V do 400 V; 0,5 A do 5 A","range":"od 100 mvar do 54 kvar","cmc":"0,10 %"},{"name":"280 V do 400 V; 5 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"},{"name":"400 V do 600 V; 0,1 A do 0,3 A","range":"od 100 mvar do 54 kvar","cmc":"0,15 %"},{"name":"400 V do 600 V; 0,3 A do 0,5 A","range":"od 100 mvar do 54 kvar","cmc":"0,11 %"},{"name":"400 V do 600 V; 0,5 A do 10 A","range":"od 100 mvar do 54 kvar","cmc":"0,10 %"},{"name":"400 V do 600 V; 10 A do 90 A","range":"od 100 mvar do 54 kvar","cmc":"0,12 %"}],"parameters_en":[{"name":"1 V to 5 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,20 %"},{"name":"1 V to 5 V; 0,3 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,18 %"},{"name":"5 V to 10 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,15 %"},{"name":"5 V to 10 V; 0,3 A to 0,7 A","range":"100 mvar to 54 kvar","cmc":"0,11 %"},{"name":"5 V to 10 V; 0,7 A to 1 A","range":"100 mvar to 54 kvar","cmc":"0,09 %"},{"name":"5 V to 10 V; 1 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"10 V to 30 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,16 %"},{"name":"10 V to 30 V; 0,3 A to 10 A","range":"100 mvar to 54 kvar","cmc":"0,11 %"},{"name":"10 V to 30 V; 10 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,13 %"},{"name":"30 V to 50 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,16 %"},{"name":"30 V to 50 V; 0,3 A to 0,9 A","range":"100 mvar to 54 kvar","cmc":"0,11 %"},{"name":"30 V to 50 V; 0,9 A to 1 A","range":"100 mvar to 54 kvar","cmc":"0,09 %"},{"name":"30 V to 50 V; 1 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"50 V to 70 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,15 %"},{"name":"50 V to 70 V; 0,3 A to 0,7 A","range":"100 mvar to 54 kvar","cmc":"0,10 %"},{"name":"50 V to 70 V; 0,7 A to 1 A","range":"100 mvar to 54 kvar","cmc":"0,09 %"},{"name":"50 V to 70 V; 1 A to 10 A","range":"100 mvar to 54 kvar","cmc":"0,10 %"},{"name":"50 V to 70 V; 10 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"70 V to 100 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,15 %"},{"name":"70 V to 100 V; 0,3 A to 0,7 A","range":"100 mvar to 54 kvar","cmc":"0,11 %"},{"name":"70 V to 100 V; 0,7 A to 1 A","range":"100 mvar to 54 kvar","cmc":"0,09 %"},{"name":"70 V to 100 V; 1 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"100 V to 140 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,15 %"},{"name":"100 V to 140 V; 0,3 A to 1 A","range":"100 mvar to 54 kvar","cmc":"0,09 %"},{"name":"100 V to 140 V; 1 A to 10 A","range":"100 mvar to 54 kvar","cmc":"0,10 %"},{"name":"100 V to 140 V; 10 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"140 V to 200 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,19 %"},{"name":"140 V to 200 V; 0,3 A to 0,7 A","range":"100 mvar to 54 kvar","cmc":"0,11 %"},{"name":"140 V to 200 V; 0,7 A to 1 A","range":"100 mvar to 54 kvar","cmc":"0,09 %"},{"name":"140 V to 200 V; 1 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"200 V to 280 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,15 %"},{"name":"200 V to 280 V; 0,3 A to 0,7 A","range":"100 mvar to 54 kvar","cmc":"0,10 %"},{"name":"200 V to 280 V; 0,7 A to 1 A","range":"100 mvar to 54 kvar","cmc":"0,09 %"},{"name":"200 V to 280 V; 1 A to 10 A","range":"100 mvar to 54 kvar","cmc":"0,10 %"},{"name":"200 V to 280 V; 10 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"280 V to 400 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,16 %"},{"name":"280 V to 400 V; 0,3 A to 0,5 A","range":"100 mvar to 54 kvar","cmc":"0,11 %"},{"name":"280 V to 400 V; 0,5 A to 5 A","range":"100 mvar to 54 kvar","cmc":"0,10 %"},{"name":"280 V to 400 V; 5 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"},{"name":"400 V to 600 V; 0,1 A to 0,3 A","range":"100 mvar to 54 kvar","cmc":"0,15 %"},{"name":"400 V to 600 V; 0,3 A to 0,5 A","range":"100 mvar to 54 kvar","cmc":"0,11 %"},{"name":"400 V to 600 V; 0,5 A to 10 A","range":"100 mvar to 54 kvar","cmc":"0,10 %"},{"name":"400 V to 600 V; 10 A to 90 A","range":"100 mvar to 54 kvar","cmc":"0,12 %"}],"parameters_zh":[{"name":"1 V 至 5 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,20 %"},{"name":"1 V 至 5 V；0,3 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,18 %"},{"name":"5 V 至 10 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,15 %"},{"name":"5 V 至 10 V；0,3 A 至 0,7 A","range":"100 mvar 至 54 kvar","cmc":"0,11 %"},{"name":"5 V 至 10 V；0,7 A 至 1 A","range":"100 mvar 至 54 kvar","cmc":"0,09 %"},{"name":"5 V 至 10 V；1 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"10 V 至 30 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,16 %"},{"name":"10 V 至 30 V；0,3 A 至 10 A","range":"100 mvar 至 54 kvar","cmc":"0,11 %"},{"name":"10 V 至 30 V；10 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,13 %"},{"name":"30 V 至 50 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,16 %"},{"name":"30 V 至 50 V；0,3 A 至 0,9 A","range":"100 mvar 至 54 kvar","cmc":"0,11 %"},{"name":"30 V 至 50 V；0,9 A 至 1 A","range":"100 mvar 至 54 kvar","cmc":"0,09 %"},{"name":"30 V 至 50 V；1 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"50 V 至 70 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,15 %"},{"name":"50 V 至 70 V；0,3 A 至 0,7 A","range":"100 mvar 至 54 kvar","cmc":"0,10 %"},{"name":"50 V 至 70 V；0,7 A 至 1 A","range":"100 mvar 至 54 kvar","cmc":"0,09 %"},{"name":"50 V 至 70 V；1 A 至 10 A","range":"100 mvar 至 54 kvar","cmc":"0,10 %"},{"name":"50 V 至 70 V；10 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"70 V 至 100 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,15 %"},{"name":"70 V 至 100 V；0,3 A 至 0,7 A","range":"100 mvar 至 54 kvar","cmc":"0,11 %"},{"name":"70 V 至 100 V；0,7 A 至 1 A","range":"100 mvar 至 54 kvar","cmc":"0,09 %"},{"name":"70 V 至 100 V；1 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"100 V 至 140 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,15 %"},{"name":"100 V 至 140 V；0,3 A 至 1 A","range":"100 mvar 至 54 kvar","cmc":"0,09 %"},{"name":"100 V 至 140 V；1 A 至 10 A","range":"100 mvar 至 54 kvar","cmc":"0,10 %"},{"name":"100 V 至 140 V；10 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"140 V 至 200 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,19 %"},{"name":"140 V 至 200 V；0,3 A 至 0,7 A","range":"100 mvar 至 54 kvar","cmc":"0,11 %"},{"name":"140 V 至 200 V；0,7 A 至 1 A","range":"100 mvar 至 54 kvar","cmc":"0,09 %"},{"name":"140 V 至 200 V；1 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"200 V 至 280 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,15 %"},{"name":"200 V 至 280 V；0,3 A 至 0,7 A","range":"100 mvar 至 54 kvar","cmc":"0,10 %"},{"name":"200 V 至 280 V；0,7 A 至 1 A","range":"100 mvar 至 54 kvar","cmc":"0,09 %"},{"name":"200 V 至 280 V；1 A 至 10 A","range":"100 mvar 至 54 kvar","cmc":"0,10 %"},{"name":"200 V 至 280 V；10 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"280 V 至 400 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,16 %"},{"name":"280 V 至 400 V；0,3 A 至 0,5 A","range":"100 mvar 至 54 kvar","cmc":"0,11 %"},{"name":"280 V 至 400 V；0,5 A 至 5 A","range":"100 mvar 至 54 kvar","cmc":"0,10 %"},{"name":"280 V 至 400 V；5 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"},{"name":"400 V 至 600 V；0,1 A 至 0,3 A","range":"100 mvar 至 54 kvar","cmc":"0,15 %"},{"name":"400 V 至 600 V；0,3 A 至 0,5 A","range":"100 mvar 至 54 kvar","cmc":"0,11 %"},{"name":"400 V 至 600 V；0,5 A 至 10 A","range":"100 mvar 至 54 kvar","cmc":"0,10 %"},{"name":"400 V 至 600 V；10 A 至 90 A","range":"100 mvar 至 54 kvar","cmc":"0,12 %"}],"parameters_cs":[{"name":"1 V až 5 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,20 %"},{"name":"1 V až 5 V; 0,3 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,18 %"},{"name":"5 V až 10 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,15 %"},{"name":"5 V až 10 V; 0,3 A až 0,7 A","range":"100 mvar až 54 kvar","cmc":"0,11 %"},{"name":"5 V až 10 V; 0,7 A až 1 A","range":"100 mvar až 54 kvar","cmc":"0,09 %"},{"name":"5 V až 10 V; 1 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"10 V až 30 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,16 %"},{"name":"10 V až 30 V; 0,3 A až 10 A","range":"100 mvar až 54 kvar","cmc":"0,11 %"},{"name":"10 V až 30 V; 10 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,13 %"},{"name":"30 V až 50 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,16 %"},{"name":"30 V až 50 V; 0,3 A až 0,9 A","range":"100 mvar až 54 kvar","cmc":"0,11 %"},{"name":"30 V až 50 V; 0,9 A až 1 A","range":"100 mvar až 54 kvar","cmc":"0,09 %"},{"name":"30 V až 50 V; 1 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"50 V až 70 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,15 %"},{"name":"50 V až 70 V; 0,3 A až 0,7 A","range":"100 mvar až 54 kvar","cmc":"0,10 %"},{"name":"50 V až 70 V; 0,7 A až 1 A","range":"100 mvar až 54 kvar","cmc":"0,09 %"},{"name":"50 V až 70 V; 1 A až 10 A","range":"100 mvar až 54 kvar","cmc":"0,10 %"},{"name":"50 V až 70 V; 10 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"70 V až 100 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,15 %"},{"name":"70 V až 100 V; 0,3 A až 0,7 A","range":"100 mvar až 54 kvar","cmc":"0,11 %"},{"name":"70 V až 100 V; 0,7 A až 1 A","range":"100 mvar až 54 kvar","cmc":"0,09 %"},{"name":"70 V až 100 V; 1 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"100 V až 140 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,15 %"},{"name":"100 V až 140 V; 0,3 A až 1 A","range":"100 mvar až 54 kvar","cmc":"0,09 %"},{"name":"100 V až 140 V; 1 A až 10 A","range":"100 mvar až 54 kvar","cmc":"0,10 %"},{"name":"100 V až 140 V; 10 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"140 V až 200 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,19 %"},{"name":"140 V až 200 V; 0,3 A až 0,7 A","range":"100 mvar až 54 kvar","cmc":"0,11 %"},{"name":"140 V až 200 V; 0,7 A až 1 A","range":"100 mvar až 54 kvar","cmc":"0,09 %"},{"name":"140 V až 200 V; 1 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"200 V až 280 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,15 %"},{"name":"200 V až 280 V; 0,3 A až 0,7 A","range":"100 mvar až 54 kvar","cmc":"0,10 %"},{"name":"200 V až 280 V; 0,7 A až 1 A","range":"100 mvar až 54 kvar","cmc":"0,09 %"},{"name":"200 V až 280 V; 1 A až 10 A","range":"100 mvar až 54 kvar","cmc":"0,10 %"},{"name":"200 V až 280 V; 10 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"280 V až 400 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,16 %"},{"name":"280 V až 400 V; 0,3 A až 0,5 A","range":"100 mvar až 54 kvar","cmc":"0,11 %"},{"name":"280 V až 400 V; 0,5 A až 5 A","range":"100 mvar až 54 kvar","cmc":"0,10 %"},{"name":"280 V až 400 V; 5 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"},{"name":"400 V až 600 V; 0,1 A až 0,3 A","range":"100 mvar až 54 kvar","cmc":"0,15 %"},{"name":"400 V až 600 V; 0,3 A až 0,5 A","range":"100 mvar až 54 kvar","cmc":"0,11 %"},{"name":"400 V až 600 V; 0,5 A až 10 A","range":"100 mvar až 54 kvar","cmc":"0,10 %"},{"name":"400 V až 600 V; 10 A až 90 A","range":"100 mvar až 54 kvar","cmc":"0,12 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 V do 5 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,20 %\n1 V do 5 V; 0,3 A do 90 A od 100 mvar do 54 kvar CMC 0,18 %\n5 V do 10 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 %\n5 V do 10 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 %\n5 V do 10 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 %\n5 V do 10 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n10 V do 30 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 %\n10 V do 30 V; 0,3 A do 10 A od 100 mvar do 54 kvar CMC 0,11 %\n10 V do 30 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,13 %\n30 V do 50 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 %\n30 V do 50 V; 0,3 A do 0,9 A od 100 mvar do 54 kvar CMC 0,11 %\n30 V do 50 V; 0,9 A do 1 A od 100 mvar do 54 kvar CMC 0,09 %\n30 V do 50 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n50 V do 70 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 %\n50 V do 70 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,10 %\n50 V do 70 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 %\n50 V do 70 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 %\n50 V do 70 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n70 V do 100 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 %\n70 V do 100 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 %\n70 V do 100 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 %\n70 V do 100 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n100 V do 140 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 %\n100 V do 140 V; 0,3 A do 1 A od 100 mvar do 54 kvar CMC 0,09 %\n100 V do 140 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 %\n100 V do 140 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n140 V do 200 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,19 %\n140 V do 200 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 %\n140 V do 200 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 %\n140 V do 200 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n200 V do 280 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 %\n200 V do 280 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,10 %\n200 V do 280 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 %\n200 V do 280 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 %\n200 V do 280 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n280 V do 400 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 %\n280 V do 400 V; 0,3 A do 0,5 A od 100 mvar do 54 kvar CMC 0,11 %\n280 V do 400 V; 0,5 A do 5 A od 100 mvar do 54 kvar CMC 0,10 %\n280 V do 400 V; 5 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\n400 V do 600 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 %\n400 V do 600 V; 0,3 A do 0,5 A od 100 mvar do 54 kvar CMC 0,11 %\n400 V do 600 V; 0,5 A do 10 A od 100 mvar do 54 kvar CMC 0,10 %\n400 V do 600 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc bierna prądu przemiennego, jedno- i trójfazowa / Watomierze prądu przemiennego, jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 0) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 1 V do 5 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,20 % 1 V do 5 V; 0,3 A do 90 A od 100 mvar do 54 kvar CMC 0,18 % 5 V do 10 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 5 V do 10 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 % 5 V do 10 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 5 V do 10 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 10 V do 30 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 % 10 V do 30 V; 0,3 A do 10 A od 100 mvar do 54 kvar CMC 0,11 % 10 V do 30 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,13 % 30 V do 50 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 % 30 V do 50 V; 0,3 A do 0,9 A od 100 mvar do 54 kvar CMC 0,11 % 30 V do 50 V; 0,9 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 30 V do 50 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 50 V do 70 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 50 V do 70 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,10 % 50 V do 70 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 50 V do 70 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 50 V do 70 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 70 V do 100 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 70 V do 100 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 % 70 V do 100 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 70 V do 100 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 100 V do 140 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 100 V do 140 V; 0,3 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 100 V do 140 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 100 V do 140 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 140 V do 200 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,19 % 140 V do 200 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 % 140 V do 200 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 140 V do 200 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 200 V do 280 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 200 V do 280 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,10 % 200 V do 280 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 200 V do 280 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 200 V do 280 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 280 V do 400 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 % 280 V do 400 V; 0,3 A do 0,5 A od 100 mvar do 54 kvar CMC 0,11 % 280 V do 400 V; 0,5 A do 5 A od 100 mvar do 54 kvar CMC 0,10 % 280 V do 400 V; 5 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 400 V do 600 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 400 V do 600 V; 0,3 A do 0,5 A od 100 mvar do 54 kvar CMC 0,11 % 400 V do 600 V; 0,5 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 400 V do 600 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % Střídavý jalový výkon, jednofázový i třífázový / Střídavé wattmetry, jednofázové i třífázové (f: 45 Hz až 65 Hz, PF = 0) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 1 V až 5 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,20 % 1 V až 5 V; 0,3 A až 90 A 100 mvar až 54 kvar CMC 0,18 % 5 V až 10 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,15 % 5 V až 10 V; 0,3 A až 0,7 A 100 mvar až 54 kvar CMC 0,11 % 5 V až 10 V; 0,7 A až 1 A 100 mvar až 54 kvar CMC 0,09 % 5 V až 10 V; 1 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 10 V až 30 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,16 % 10 V až 30 V; 0,3 A až 10 A 100 mvar až 54 kvar CMC 0,11 % 10 V až 30 V; 10 A až 90 A 100 mvar až 54 kvar CMC 0,13 % 30 V až 50 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,16 % 30 V až 50 V; 0,3 A až 0,9 A 100 mvar až 54 kvar CMC 0,11 % 30 V až 50 V; 0,9 A až 1 A 100 mvar až 54 kvar CMC 0,09 % 30 V až 50 V; 1 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 50 V až 70 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,15 % 50 V až 70 V; 0,3 A až 0,7 A 100 mvar až 54 kvar CMC 0,10 % 50 V až 70 V; 0,7 A až 1 A 100 mvar až 54 kvar CMC 0,09 % 50 V až 70 V; 1 A až 10 A 100 mvar až 54 kvar CMC 0,10 % 50 V až 70 V; 10 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 70 V až 100 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,15 % 70 V až 100 V; 0,3 A až 0,7 A 100 mvar až 54 kvar CMC 0,11 % 70 V až 100 V; 0,7 A až 1 A 100 mvar až 54 kvar CMC 0,09 % 70 V až 100 V; 1 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 100 V až 140 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,15 % 100 V až 140 V; 0,3 A až 1 A 100 mvar až 54 kvar CMC 0,09 % 100 V až 140 V; 1 A až 10 A 100 mvar až 54 kvar CMC 0,10 % 100 V až 140 V; 10 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 140 V až 200 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,19 % 140 V až 200 V; 0,3 A až 0,7 A 100 mvar až 54 kvar CMC 0,11 % 140 V až 200 V; 0,7 A až 1 A 100 mvar až 54 kvar CMC 0,09 % 140 V až 200 V; 1 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 200 V až 280 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,15 % 200 V až 280 V; 0,3 A až 0,7 A 100 mvar až 54 kvar CMC 0,10 % 200 V až 280 V; 0,7 A až 1 A 100 mvar až 54 kvar CMC 0,09 % 200 V až 280 V; 1 A až 10 A 100 mvar až 54 kvar CMC 0,10 % 200 V až 280 V; 10 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 280 V až 400 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,16 % 280 V až 400 V; 0,3 A až 0,5 A 100 mvar až 54 kvar CMC 0,11 % 280 V až 400 V; 0,5 A až 5 A 100 mvar až 54 kvar CMC 0,10 % 280 V až 400 V; 5 A až 90 A 100 mvar až 54 kvar CMC 0,12 % 400 V až 600 V; 0,1 A až 0,3 A 100 mvar až 54 kvar CMC 0,15 % 400 V až 600 V; 0,3 A až 0,5 A 100 mvar až 54 kvar CMC 0,11 % 400 V až 600 V; 0,5 A až 10 A 100 mvar až 54 kvar CMC 0,10 % 400 V až 600 V; 10 A až 90 A 100 mvar až 54 kvar CMC 0,12 % TP16 Moc bierna pradu przemiennego, jedno- i trojfazowa / Watomierze pradu przemiennego, jedno- i trojfazowe (f: 45 Hz do 65 Hz, PF = 0) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 1 V do 5 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,20 % 1 V do 5 V; 0,3 A do 90 A od 100 mvar do 54 kvar CMC 0,18 % 5 V do 10 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 5 V do 10 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 % 5 V do 10 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 5 V do 10 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 10 V do 30 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 % 10 V do 30 V; 0,3 A do 10 A od 100 mvar do 54 kvar CMC 0,11 % 10 V do 30 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,13 % 30 V do 50 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 % 30 V do 50 V; 0,3 A do 0,9 A od 100 mvar do 54 kvar CMC 0,11 % 30 V do 50 V; 0,9 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 30 V do 50 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 50 V do 70 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 50 V do 70 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,10 % 50 V do 70 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 50 V do 70 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 50 V do 70 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 70 V do 100 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 70 V do 100 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 % 70 V do 100 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 70 V do 100 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 100 V do 140 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 100 V do 140 V; 0,3 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 100 V do 140 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 100 V do 140 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 140 V do 200 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,19 % 140 V do 200 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,11 % 140 V do 200 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 140 V do 200 V; 1 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 200 V do 280 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 200 V do 280 V; 0,3 A do 0,7 A od 100 mvar do 54 kvar CMC 0,10 % 200 V do 280 V; 0,7 A do 1 A od 100 mvar do 54 kvar CMC 0,09 % 200 V do 280 V; 1 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 200 V do 280 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 280 V do 400 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,16 % 280 V do 400 V; 0,3 A do 0,5 A od 100 mvar do 54 kvar CMC 0,11 % 280 V do 400 V; 0,5 A do 5 A od 100 mvar do 54 kvar CMC 0,10 % 280 V do 400 V; 5 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % 400 V do 600 V; 0,1 A do 0,3 A od 100 mvar do 54 kvar CMC 0,15 % 400 V do 600 V; 0,3 A do 0,5 A od 100 mvar do 54 kvar CMC 0,11 % 400 V do 600 V; 0,5 A do 10 A od 100 mvar do 54 kvar CMC 0,10 % 400 V do 600 V; 10 A do 90 A od 100 mvar do 54 kvar CMC 0,12 % Stridavy jalovy vykon, jednofazovy i trifazovy / Stridave wattmetry, jednofazove i trifazove (f: 45 Hz az 65 Hz, PF = 0) Kalibrace – elektricke veliciny Prime generovani kalibratorem 1 V az 5 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,20 % 1 V az 5 V; 0,3 A az 90 A 100 mvar az 54 kvar CMC 0,18 % 5 V az 10 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,15 % 5 V az 10 V; 0,3 A az 0,7 A 100 mvar az 54 kvar CMC 0,11 % 5 V az 10 V; 0,7 A az 1 A 100 mvar az 54 kvar CMC 0,09 % 5 V az 10 V; 1 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 10 V az 30 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,16 % 10 V az 30 V; 0,3 A az 10 A 100 mvar az 54 kvar CMC 0,11 % 10 V az 30 V; 10 A az 90 A 100 mvar az 54 kvar CMC 0,13 % 30 V az 50 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,16 % 30 V az 50 V; 0,3 A az 0,9 A 100 mvar az 54 kvar CMC 0,11 % 30 V az 50 V; 0,9 A az 1 A 100 mvar az 54 kvar CMC 0,09 % 30 V az 50 V; 1 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 50 V az 70 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,15 % 50 V az 70 V; 0,3 A az 0,7 A 100 mvar az 54 kvar CMC 0,10 % 50 V az 70 V; 0,7 A az 1 A 100 mvar az 54 kvar CMC 0,09 % 50 V az 70 V; 1 A az 10 A 100 mvar az 54 kvar CMC 0,10 % 50 V az 70 V; 10 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 70 V az 100 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,15 % 70 V az 100 V; 0,3 A az 0,7 A 100 mvar az 54 kvar CMC 0,11 % 70 V az 100 V; 0,7 A az 1 A 100 mvar az 54 kvar CMC 0,09 % 70 V az 100 V; 1 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 100 V az 140 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,15 % 100 V az 140 V; 0,3 A az 1 A 100 mvar az 54 kvar CMC 0,09 % 100 V az 140 V; 1 A az 10 A 100 mvar az 54 kvar CMC 0,10 % 100 V az 140 V; 10 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 140 V az 200 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,19 % 140 V az 200 V; 0,3 A az 0,7 A 100 mvar az 54 kvar CMC 0,11 % 140 V az 200 V; 0,7 A az 1 A 100 mvar az 54 kvar CMC 0,09 % 140 V az 200 V; 1 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 200 V az 280 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,15 % 200 V az 280 V; 0,3 A az 0,7 A 100 mvar az 54 kvar CMC 0,10 % 200 V az 280 V; 0,7 A az 1 A 100 mvar az 54 kvar CMC 0,09 % 200 V az 280 V; 1 A az 10 A 100 mvar az 54 kvar CMC 0,10 % 200 V az 280 V; 10 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 280 V az 400 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,16 % 280 V az 400 V; 0,3 A az 0,5 A 100 mvar az 54 kvar CMC 0,11 % 280 V az 400 V; 0,5 A az 5 A 100 mvar az 54 kvar CMC 0,10 % 280 V az 400 V; 5 A az 90 A 100 mvar az 54 kvar CMC 0,12 % 400 V az 600 V; 0,1 A az 0,3 A 100 mvar az 54 kvar CMC 0,15 % 400 V az 600 V; 0,3 A az 0,5 A 100 mvar az 54 kvar CMC 0,11 % 400 V az 600 V; 0,5 A az 10 A 100 mvar az 54 kvar CMC 0,10 % 400 V az 600 V; 10 A az 90 A 100 mvar az 54 kvar CMC 0,12 % TP16","search_en":"AC reactive power, single- and three-phase / AC wattmeters, single- and three-phase (f: 45 Hz to 65 Hz, PF = 0) Calibration – electrical quantities Direct generation with a calibrator 1 V to 5 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,20 % 1 V to 5 V; 0,3 A to 90 A 100 mvar to 54 kvar CMC 0,18 % 5 V to 10 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,15 % 5 V to 10 V; 0,3 A to 0,7 A 100 mvar to 54 kvar CMC 0,11 % 5 V to 10 V; 0,7 A to 1 A 100 mvar to 54 kvar CMC 0,09 % 5 V to 10 V; 1 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 10 V to 30 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,16 % 10 V to 30 V; 0,3 A to 10 A 100 mvar to 54 kvar CMC 0,11 % 10 V to 30 V; 10 A to 90 A 100 mvar to 54 kvar CMC 0,13 % 30 V to 50 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,16 % 30 V to 50 V; 0,3 A to 0,9 A 100 mvar to 54 kvar CMC 0,11 % 30 V to 50 V; 0,9 A to 1 A 100 mvar to 54 kvar CMC 0,09 % 30 V to 50 V; 1 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 50 V to 70 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,15 % 50 V to 70 V; 0,3 A to 0,7 A 100 mvar to 54 kvar CMC 0,10 % 50 V to 70 V; 0,7 A to 1 A 100 mvar to 54 kvar CMC 0,09 % 50 V to 70 V; 1 A to 10 A 100 mvar to 54 kvar CMC 0,10 % 50 V to 70 V; 10 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 70 V to 100 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,15 % 70 V to 100 V; 0,3 A to 0,7 A 100 mvar to 54 kvar CMC 0,11 % 70 V to 100 V; 0,7 A to 1 A 100 mvar to 54 kvar CMC 0,09 % 70 V to 100 V; 1 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 100 V to 140 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,15 % 100 V to 140 V; 0,3 A to 1 A 100 mvar to 54 kvar CMC 0,09 % 100 V to 140 V; 1 A to 10 A 100 mvar to 54 kvar CMC 0,10 % 100 V to 140 V; 10 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 140 V to 200 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,19 % 140 V to 200 V; 0,3 A to 0,7 A 100 mvar to 54 kvar CMC 0,11 % 140 V to 200 V; 0,7 A to 1 A 100 mvar to 54 kvar CMC 0,09 % 140 V to 200 V; 1 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 200 V to 280 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,15 % 200 V to 280 V; 0,3 A to 0,7 A 100 mvar to 54 kvar CMC 0,10 % 200 V to 280 V; 0,7 A to 1 A 100 mvar to 54 kvar CMC 0,09 % 200 V to 280 V; 1 A to 10 A 100 mvar to 54 kvar CMC 0,10 % 200 V to 280 V; 10 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 280 V to 400 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,16 % 280 V to 400 V; 0,3 A to 0,5 A 100 mvar to 54 kvar CMC 0,11 % 280 V to 400 V; 0,5 A to 5 A 100 mvar to 54 kvar CMC 0,10 % 280 V to 400 V; 5 A to 90 A 100 mvar to 54 kvar CMC 0,12 % 400 V to 600 V; 0,1 A to 0,3 A 100 mvar to 54 kvar CMC 0,15 % 400 V to 600 V; 0,3 A to 0,5 A 100 mvar to 54 kvar CMC 0,11 % 400 V to 600 V; 0,5 A to 10 A 100 mvar to 54 kvar CMC 0,10 % 400 V to 600 V; 10 A to 90 A 100 mvar to 54 kvar CMC 0,12 % TP16","search_zh":"单相和三相交流无功功率 / 单相和三相交流功率计（f：45 Hz 至 65 Hz，PF = 0） 校准 – 电学量 用校准器直接产生 1 V 至 5 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,20 % 1 V 至 5 V；0,3 A 至 90 A 100 mvar 至 54 kvar CMC 0,18 % 5 V 至 10 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,15 % 5 V 至 10 V；0,3 A 至 0,7 A 100 mvar 至 54 kvar CMC 0,11 % 5 V 至 10 V；0,7 A 至 1 A 100 mvar 至 54 kvar CMC 0,09 % 5 V 至 10 V；1 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 10 V 至 30 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,16 % 10 V 至 30 V；0,3 A 至 10 A 100 mvar 至 54 kvar CMC 0,11 % 10 V 至 30 V；10 A 至 90 A 100 mvar 至 54 kvar CMC 0,13 % 30 V 至 50 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,16 % 30 V 至 50 V；0,3 A 至 0,9 A 100 mvar 至 54 kvar CMC 0,11 % 30 V 至 50 V；0,9 A 至 1 A 100 mvar 至 54 kvar CMC 0,09 % 30 V 至 50 V；1 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 50 V 至 70 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,15 % 50 V 至 70 V；0,3 A 至 0,7 A 100 mvar 至 54 kvar CMC 0,10 % 50 V 至 70 V；0,7 A 至 1 A 100 mvar 至 54 kvar CMC 0,09 % 50 V 至 70 V；1 A 至 10 A 100 mvar 至 54 kvar CMC 0,10 % 50 V 至 70 V；10 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 70 V 至 100 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,15 % 70 V 至 100 V；0,3 A 至 0,7 A 100 mvar 至 54 kvar CMC 0,11 % 70 V 至 100 V；0,7 A 至 1 A 100 mvar 至 54 kvar CMC 0,09 % 70 V 至 100 V；1 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 100 V 至 140 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,15 % 100 V 至 140 V；0,3 A 至 1 A 100 mvar 至 54 kvar CMC 0,09 % 100 V 至 140 V；1 A 至 10 A 100 mvar 至 54 kvar CMC 0,10 % 100 V 至 140 V；10 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 140 V 至 200 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,19 % 140 V 至 200 V；0,3 A 至 0,7 A 100 mvar 至 54 kvar CMC 0,11 % 140 V 至 200 V；0,7 A 至 1 A 100 mvar 至 54 kvar CMC 0,09 % 140 V 至 200 V；1 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 200 V 至 280 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,15 % 200 V 至 280 V；0,3 A 至 0,7 A 100 mvar 至 54 kvar CMC 0,10 % 200 V 至 280 V；0,7 A 至 1 A 100 mvar 至 54 kvar CMC 0,09 % 200 V 至 280 V；1 A 至 10 A 100 mvar 至 54 kvar CMC 0,10 % 200 V 至 280 V；10 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 280 V 至 400 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,16 % 280 V 至 400 V；0,3 A 至 0,5 A 100 mvar 至 54 kvar CMC 0,11 % 280 V 至 400 V；0,5 A 至 5 A 100 mvar 至 54 kvar CMC 0,10 % 280 V 至 400 V；5 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % 400 V 至 600 V；0,1 A 至 0,3 A 100 mvar 至 54 kvar CMC 0,15 % 400 V 至 600 V；0,3 A 至 0,5 A 100 mvar 至 54 kvar CMC 0,11 % 400 V 至 600 V；0,5 A 至 10 A 100 mvar 至 54 kvar CMC 0,10 % 400 V 至 600 V；10 A 至 90 A 100 mvar 至 54 kvar CMC 0,12 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"206a261c5cb091eee2484e69","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"20","test_object":"Współczynnik mocy (1 V do 600 V, f: 45 Hz do 65 Hz)","test_object_en":"Power factor (1 V to 600 V, f: 45 Hz to 65 Hz)","test_object_zh":"功率因数（1 V 至 600 V，f：45 Hz 至 65 Hz）","test_object_cs":"Účiník (1 V až 600 V, f: 45 Hz až 65 Hz)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 mA do 10 A","range":"od 0,02 do 0,035","cmc":"0,009 (abs.)"},{"name":"100 mA do 10 A","range":"od 0,035 do 0,088","cmc":"0,005 (abs.)"},{"name":"100 mA do 10 A","range":"od 0,088 do 0,1","cmc":"0,002 (abs.)"},{"name":"10 mA do 100 mA","range":"od 0,1 do 0,174","cmc":"0,009 (abs.)"},{"name":"100 mA do 10 A","range":"od 0,1 do 0,174","cmc":"0,002 (abs.)"},{"name":"10 A do 30 A","range":"od 0,1 do 0,174","cmc":"0,009 (abs.)"},{"name":"10 mA do 100 mA","range":"od 0,174 do 0,3","cmc":"0,005 (abs.)"},{"name":"100 mA do 10 A","range":"od 0,174 do 0,3","cmc":"0,001 (abs.)"},{"name":"10 A do 30 A","range":"od 0,174 do 0,3","cmc":"0,005 (abs.)"},{"name":"10 mA do 100 mA","range":"od 0,3 do 0,4","cmc":"0,003 (abs.)"},{"name":"100 mA do 10 A","range":"od 0,3 do 0,4","cmc":"0,001 (abs.)"},{"name":"10 A do 30 A","range":"od 0,3 do 0,4","cmc":"0,003 (abs.)"},{"name":"10 mA do 100 mA","range":"od 0,4 do 0,7","cmc":"0,002 (abs.)"},{"name":"100 mA do 10 A","range":"od 0,4 do 0,7","cmc":"0,001 (abs.)"},{"name":"10 A do 30 A","range":"od 0,4 do 0,7","cmc":"0,002 (abs.)"},{"name":"10 mA do 30 A","range":"od 0,7 do 1","cmc":"0,001 (abs.)"}],"parameters_en":[{"name":"100 mA to 10 A","range":"0,02 to 0,035","cmc":"0,009 (abs.)"},{"name":"100 mA to 10 A","range":"0,035 to 0,088","cmc":"0,005 (abs.)"},{"name":"100 mA to 10 A","range":"0,088 to 0,1","cmc":"0,002 (abs.)"},{"name":"10 mA to 100 mA","range":"0,1 to 0,174","cmc":"0,009 (abs.)"},{"name":"100 mA to 10 A","range":"0,1 to 0,174","cmc":"0,002 (abs.)"},{"name":"10 A to 30 A","range":"0,1 to 0,174","cmc":"0,009 (abs.)"},{"name":"10 mA to 100 mA","range":"0,174 to 0,3","cmc":"0,005 (abs.)"},{"name":"100 mA to 10 A","range":"0,174 to 0,3","cmc":"0,001 (abs.)"},{"name":"10 A to 30 A","range":"0,174 to 0,3","cmc":"0,005 (abs.)"},{"name":"10 mA to 100 mA","range":"0,3 to 0,4","cmc":"0,003 (abs.)"},{"name":"100 mA to 10 A","range":"0,3 to 0,4","cmc":"0,001 (abs.)"},{"name":"10 A to 30 A","range":"0,3 to 0,4","cmc":"0,003 (abs.)"},{"name":"10 mA to 100 mA","range":"0,4 to 0,7","cmc":"0,002 (abs.)"},{"name":"100 mA to 10 A","range":"0,4 to 0,7","cmc":"0,001 (abs.)"},{"name":"10 A to 30 A","range":"0,4 to 0,7","cmc":"0,002 (abs.)"},{"name":"10 mA to 30 A","range":"0,7 to 1","cmc":"0,001 (abs.)"}],"parameters_zh":[{"name":"100 mA 至 10 A","range":"0,02 至 0,035","cmc":"0,009 (abs.)"},{"name":"100 mA 至 10 A","range":"0,035 至 0,088","cmc":"0,005 (abs.)"},{"name":"100 mA 至 10 A","range":"0,088 至 0,1","cmc":"0,002 (abs.)"},{"name":"10 mA 至 100 mA","range":"0,1 至 0,174","cmc":"0,009 (abs.)"},{"name":"100 mA 至 10 A","range":"0,1 至 0,174","cmc":"0,002 (abs.)"},{"name":"10 A 至 30 A","range":"0,1 至 0,174","cmc":"0,009 (abs.)"},{"name":"10 mA 至 100 mA","range":"0,174 至 0,3","cmc":"0,005 (abs.)"},{"name":"100 mA 至 10 A","range":"0,174 至 0,3","cmc":"0,001 (abs.)"},{"name":"10 A 至 30 A","range":"0,174 至 0,3","cmc":"0,005 (abs.)"},{"name":"10 mA 至 100 mA","range":"0,3 至 0,4","cmc":"0,003 (abs.)"},{"name":"100 mA 至 10 A","range":"0,3 至 0,4","cmc":"0,001 (abs.)"},{"name":"10 A 至 30 A","range":"0,3 至 0,4","cmc":"0,003 (abs.)"},{"name":"10 mA 至 100 mA","range":"0,4 至 0,7","cmc":"0,002 (abs.)"},{"name":"100 mA 至 10 A","range":"0,4 至 0,7","cmc":"0,001 (abs.)"},{"name":"10 A 至 30 A","range":"0,4 至 0,7","cmc":"0,002 (abs.)"},{"name":"10 mA 至 30 A","range":"0,7 至 1","cmc":"0,001 (abs.)"}],"parameters_cs":[{"name":"100 mA až 10 A","range":"0,02 až 0,035","cmc":"0,009 (abs.)"},{"name":"100 mA až 10 A","range":"0,035 až 0,088","cmc":"0,005 (abs.)"},{"name":"100 mA až 10 A","range":"0,088 až 0,1","cmc":"0,002 (abs.)"},{"name":"10 mA až 100 mA","range":"0,1 až 0,174","cmc":"0,009 (abs.)"},{"name":"100 mA až 10 A","range":"0,1 až 0,174","cmc":"0,002 (abs.)"},{"name":"10 A až 30 A","range":"0,1 až 0,174","cmc":"0,009 (abs.)"},{"name":"10 mA až 100 mA","range":"0,174 až 0,3","cmc":"0,005 (abs.)"},{"name":"100 mA až 10 A","range":"0,174 až 0,3","cmc":"0,001 (abs.)"},{"name":"10 A až 30 A","range":"0,174 až 0,3","cmc":"0,005 (abs.)"},{"name":"10 mA až 100 mA","range":"0,3 až 0,4","cmc":"0,003 (abs.)"},{"name":"100 mA až 10 A","range":"0,3 až 0,4","cmc":"0,001 (abs.)"},{"name":"10 A až 30 A","range":"0,3 až 0,4","cmc":"0,003 (abs.)"},{"name":"10 mA až 100 mA","range":"0,4 až 0,7","cmc":"0,002 (abs.)"},{"name":"100 mA až 10 A","range":"0,4 až 0,7","cmc":"0,001 (abs.)"},{"name":"10 A až 30 A","range":"0,4 až 0,7","cmc":"0,002 (abs.)"},{"name":"10 mA až 30 A","range":"0,7 až 1","cmc":"0,001 (abs.)"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n100 mA do 10 A od 0,02 do 0,035 CMC 0,009 (abs.)\n100 mA do 10 A od 0,035 do 0,088 CMC 0,005 (abs.)\n100 mA do 10 A od 0,088 do 0,1 CMC 0,002 (abs.)\n10 mA do 100 mA od 0,1 do 0,174 CMC 0,009 (abs.)\n100 mA do 10 A od 0,1 do 0,174 CMC 0,002 (abs.)\n10 A do 30 A od 0,1 do 0,174 CMC 0,009 (abs.)\n10 mA do 100 mA od 0,174 do 0,3 CMC 0,005 (abs.)\n100 mA do 10 A od 0,174 do 0,3 CMC 0,001 (abs.)\n10 A do 30 A od 0,174 do 0,3 CMC 0,005 (abs.)\n10 mA do 100 mA od 0,3 do 0,4 CMC 0,003 (abs.)\n100 mA do 10 A od 0,3 do 0,4 CMC 0,001 (abs.)\n10 A do 30 A od 0,3 do 0,4 CMC 0,003 (abs.)\n10 mA do 100 mA od 0,4 do 0,7 CMC 0,002 (abs.)\n100 mA do 10 A od 0,4 do 0,7 CMC 0,001 (abs.)\n10 A do 30 A od 0,4 do 0,7 CMC 0,002 (abs.)\n10 mA do 30 A od 0,7 do 1 CMC 0,001 (abs.)\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik mocy (1 V do 600 V, f: 45 Hz do 65 Hz) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 100 mA do 10 A od 0,02 do 0,035 CMC 0,009 (abs.) 100 mA do 10 A od 0,035 do 0,088 CMC 0,005 (abs.) 100 mA do 10 A od 0,088 do 0,1 CMC 0,002 (abs.) 10 mA do 100 mA od 0,1 do 0,174 CMC 0,009 (abs.) 100 mA do 10 A od 0,1 do 0,174 CMC 0,002 (abs.) 10 A do 30 A od 0,1 do 0,174 CMC 0,009 (abs.) 10 mA do 100 mA od 0,174 do 0,3 CMC 0,005 (abs.) 100 mA do 10 A od 0,174 do 0,3 CMC 0,001 (abs.) 10 A do 30 A od 0,174 do 0,3 CMC 0,005 (abs.) 10 mA do 100 mA od 0,3 do 0,4 CMC 0,003 (abs.) 100 mA do 10 A od 0,3 do 0,4 CMC 0,001 (abs.) 10 A do 30 A od 0,3 do 0,4 CMC 0,003 (abs.) 10 mA do 100 mA od 0,4 do 0,7 CMC 0,002 (abs.) 100 mA do 10 A od 0,4 do 0,7 CMC 0,001 (abs.) 10 A do 30 A od 0,4 do 0,7 CMC 0,002 (abs.) 10 mA do 30 A od 0,7 do 1 CMC 0,001 (abs.) Účiník (1 V až 600 V, f: 45 Hz až 65 Hz) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 100 mA až 10 A 0,02 až 0,035 CMC 0,009 (abs.) 100 mA až 10 A 0,035 až 0,088 CMC 0,005 (abs.) 100 mA až 10 A 0,088 až 0,1 CMC 0,002 (abs.) 10 mA až 100 mA 0,1 až 0,174 CMC 0,009 (abs.) 100 mA až 10 A 0,1 až 0,174 CMC 0,002 (abs.) 10 A až 30 A 0,1 až 0,174 CMC 0,009 (abs.) 10 mA až 100 mA 0,174 až 0,3 CMC 0,005 (abs.) 100 mA až 10 A 0,174 až 0,3 CMC 0,001 (abs.) 10 A až 30 A 0,174 až 0,3 CMC 0,005 (abs.) 10 mA až 100 mA 0,3 až 0,4 CMC 0,003 (abs.) 100 mA až 10 A 0,3 až 0,4 CMC 0,001 (abs.) 10 A až 30 A 0,3 až 0,4 CMC 0,003 (abs.) 10 mA až 100 mA 0,4 až 0,7 CMC 0,002 (abs.) 100 mA až 10 A 0,4 až 0,7 CMC 0,001 (abs.) 10 A až 30 A 0,4 až 0,7 CMC 0,002 (abs.) 10 mA až 30 A 0,7 až 1 CMC 0,001 (abs.) TP16 Wspolczynnik mocy (1 V do 600 V, f: 45 Hz do 65 Hz) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 100 mA do 10 A od 0,02 do 0,035 CMC 0,009 (abs.) 100 mA do 10 A od 0,035 do 0,088 CMC 0,005 (abs.) 100 mA do 10 A od 0,088 do 0,1 CMC 0,002 (abs.) 10 mA do 100 mA od 0,1 do 0,174 CMC 0,009 (abs.) 100 mA do 10 A od 0,1 do 0,174 CMC 0,002 (abs.) 10 A do 30 A od 0,1 do 0,174 CMC 0,009 (abs.) 10 mA do 100 mA od 0,174 do 0,3 CMC 0,005 (abs.) 100 mA do 10 A od 0,174 do 0,3 CMC 0,001 (abs.) 10 A do 30 A od 0,174 do 0,3 CMC 0,005 (abs.) 10 mA do 100 mA od 0,3 do 0,4 CMC 0,003 (abs.) 100 mA do 10 A od 0,3 do 0,4 CMC 0,001 (abs.) 10 A do 30 A od 0,3 do 0,4 CMC 0,003 (abs.) 10 mA do 100 mA od 0,4 do 0,7 CMC 0,002 (abs.) 100 mA do 10 A od 0,4 do 0,7 CMC 0,001 (abs.) 10 A do 30 A od 0,4 do 0,7 CMC 0,002 (abs.) 10 mA do 30 A od 0,7 do 1 CMC 0,001 (abs.) Ucinik (1 V az 600 V, f: 45 Hz az 65 Hz) Kalibrace – elektricke veliciny Prime generovani kalibratorem 100 mA az 10 A 0,02 az 0,035 CMC 0,009 (abs.) 100 mA az 10 A 0,035 az 0,088 CMC 0,005 (abs.) 100 mA az 10 A 0,088 az 0,1 CMC 0,002 (abs.) 10 mA az 100 mA 0,1 az 0,174 CMC 0,009 (abs.) 100 mA az 10 A 0,1 az 0,174 CMC 0,002 (abs.) 10 A az 30 A 0,1 az 0,174 CMC 0,009 (abs.) 10 mA az 100 mA 0,174 az 0,3 CMC 0,005 (abs.) 100 mA az 10 A 0,174 az 0,3 CMC 0,001 (abs.) 10 A az 30 A 0,174 az 0,3 CMC 0,005 (abs.) 10 mA az 100 mA 0,3 az 0,4 CMC 0,003 (abs.) 100 mA az 10 A 0,3 az 0,4 CMC 0,001 (abs.) 10 A az 30 A 0,3 az 0,4 CMC 0,003 (abs.) 10 mA az 100 mA 0,4 az 0,7 CMC 0,002 (abs.) 100 mA az 10 A 0,4 az 0,7 CMC 0,001 (abs.) 10 A az 30 A 0,4 az 0,7 CMC 0,002 (abs.) 10 mA az 30 A 0,7 az 1 CMC 0,001 (abs.) TP16","search_en":"Power factor (1 V to 600 V, f: 45 Hz to 65 Hz) Calibration – electrical quantities Direct generation with a calibrator 100 mA to 10 A 0,02 to 0,035 CMC 0,009 (abs.) 100 mA to 10 A 0,035 to 0,088 CMC 0,005 (abs.) 100 mA to 10 A 0,088 to 0,1 CMC 0,002 (abs.) 10 mA to 100 mA 0,1 to 0,174 CMC 0,009 (abs.) 100 mA to 10 A 0,1 to 0,174 CMC 0,002 (abs.) 10 A to 30 A 0,1 to 0,174 CMC 0,009 (abs.) 10 mA to 100 mA 0,174 to 0,3 CMC 0,005 (abs.) 100 mA to 10 A 0,174 to 0,3 CMC 0,001 (abs.) 10 A to 30 A 0,174 to 0,3 CMC 0,005 (abs.) 10 mA to 100 mA 0,3 to 0,4 CMC 0,003 (abs.) 100 mA to 10 A 0,3 to 0,4 CMC 0,001 (abs.) 10 A to 30 A 0,3 to 0,4 CMC 0,003 (abs.) 10 mA to 100 mA 0,4 to 0,7 CMC 0,002 (abs.) 100 mA to 10 A 0,4 to 0,7 CMC 0,001 (abs.) 10 A to 30 A 0,4 to 0,7 CMC 0,002 (abs.) 10 mA to 30 A 0,7 to 1 CMC 0,001 (abs.) TP16","search_zh":"功率因数（1 V 至 600 V，f：45 Hz 至 65 Hz） 校准 – 电学量 用校准器直接产生 100 mA 至 10 A 0,02 至 0,035 CMC 0,009 (abs.) 100 mA 至 10 A 0,035 至 0,088 CMC 0,005 (abs.) 100 mA 至 10 A 0,088 至 0,1 CMC 0,002 (abs.) 10 mA 至 100 mA 0,1 至 0,174 CMC 0,009 (abs.) 100 mA 至 10 A 0,1 至 0,174 CMC 0,002 (abs.) 10 A 至 30 A 0,1 至 0,174 CMC 0,009 (abs.) 10 mA 至 100 mA 0,174 至 0,3 CMC 0,005 (abs.) 100 mA 至 10 A 0,174 至 0,3 CMC 0,001 (abs.) 10 A 至 30 A 0,174 至 0,3 CMC 0,005 (abs.) 10 mA 至 100 mA 0,3 至 0,4 CMC 0,003 (abs.) 100 mA 至 10 A 0,3 至 0,4 CMC 0,001 (abs.) 10 A 至 30 A 0,3 至 0,4 CMC 0,003 (abs.) 10 mA 至 100 mA 0,4 至 0,7 CMC 0,002 (abs.) 100 mA 至 10 A 0,4 至 0,7 CMC 0,001 (abs.) 10 A 至 30 A 0,4 至 0,7 CMC 0,002 (abs.) 10 mA 至 30 A 0,7 至 1 CMC 0,001 (abs.) TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d8c70e567d164d08d3e2fabd","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"21","test_object":"Energia elektryczna prądu stałego / Liczniki energii elektrycznej prądu stałego (t: 600 s do 24 h)","test_object_en":"DC electrical work / DC electrical work meters (t: 600 s to 24 h)","test_object_zh":"直流电能 / 直流电能表（t：600 s 至 24 h）","test_object_cs":"Stejnosměrná elektrická práce / Stejnosměrná měřidla elektrické práce (t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"33 mV do 25 V; 3,3 mA do 9 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV do 25 V; 9 mA do 33 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV do 25 V; 33 mA do 90 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV do 25 V; 90 mA do 330 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV do 25 V; 0,33 A do 0,9 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,090 %"},{"name":"33 mV do 25 V; 0,9 A do 2,2 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,070 %"},{"name":"33 mV do 25 V; 2,2 A do 4,5 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,13 %"},{"name":"33 mV do 25 V; 4,5 A do 11 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,10 %"},{"name":"33 mV do 25 V; 11 A do 20 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV do 25 V; 20 A do 30 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,079 %"},{"name":"33 mV do 25 V; 30 A do 60 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV do 25 V; 60 A do 90 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,079 %"},{"name":"25 V do 100 V; 3,3 mA do 9 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"25 V do 100 V; 9 mA do 33 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"25 V do 100 V; 33 mA do 50 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"25 V do 100 V; 50 mA do 100 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,040 %"},{"name":"25 V do 100 V; 100 mA do 330 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"25 V do 100 V; 0,33 A do 0,9 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,090 %"},{"name":"25 V do 100 V; 0,9 A do 2,2 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,070 %"},{"name":"25 V do 100 V; 2,2 A do 4,5 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,13 %"},{"name":"25 V do 100 V; 4,5 A do 11 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,10 %"},{"name":"25 V do 100 V; 11 A do 20 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,092 %"},{"name":"25 V do 100 V; 20 A do 30 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,075 %"},{"name":"25 V do 100 V; 30 A do 60 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,092 %"},{"name":"25 V do 100 V; 60 A do 90 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,075 %"},{"name":"100 V do 280 V; 3,3 mA do 9 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"100 V do 280 V; 9 mA do 33 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"100 V do 280 V; 33 mA do 90 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"100 V do 280 V; 90 mA do 330 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"100 V do 280 V; 0,33 A do 0,9 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,090 %"},{"name":"100 V do 280 V; 0,9 A do 2,2 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,070 %"},{"name":"100 V do 280 V; 2,2 A do 4,5 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,13 %"},{"name":"100 V do 280 V; 4,5 A do 11 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,10 %"},{"name":"100 V do 280 V; 11 A do 20 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,089 %"},{"name":"100 V do 280 V; 20 A do 30 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,073 %"},{"name":"100 V do 280 V; 30 A do 60 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,089 %"},{"name":"100 V do 280 V; 60 A do 90 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,073 %"},{"name":"280 V do 1000 V; 3,3 mA do 9 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"280 V do 1000 V; 9 mA do 33 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"280 V do 1000 V; 33 mA do 90 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,055 %"},{"name":"280 V do 1000 V; 90 mA do 330 mA","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,050 %"},{"name":"280 V do 1000 V; 0,33 A do 0,9 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,090 %"},{"name":"280 V do 1000 V; 0,9 A do 2,2 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,070 %"},{"name":"280 V do 1000 V; 2,2 A do 4,5 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,13 %"},{"name":"280 V do 1000 V; 4,5 A do 11 A","range":"od 0,66 Ws do 2,177 GWs","cmc":"0,10 %"}],"parameters_en":[{"name":"33 mV to 25 V; 3,3 mA to 9 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV to 25 V; 9 mA to 33 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV to 25 V; 33 mA to 90 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV to 25 V; 90 mA to 330 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV to 25 V; 0,33 A to 0,9 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,090 %"},{"name":"33 mV to 25 V; 0,9 A to 2,2 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,070 %"},{"name":"33 mV to 25 V; 2,2 A to 4,5 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,13 %"},{"name":"33 mV to 25 V; 4,5 A to 11 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,10 %"},{"name":"33 mV to 25 V; 11 A to 20 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV to 25 V; 20 A to 30 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,079 %"},{"name":"33 mV to 25 V; 30 A to 60 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV to 25 V; 60 A to 90 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,079 %"},{"name":"25 V to 100 V; 3,3 mA to 9 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"25 V to 100 V; 9 mA to 33 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"25 V to 100 V; 33 mA to 50 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"25 V to 100 V; 50 mA to 100 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,040 %"},{"name":"25 V to 100 V; 100 mA to 330 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"25 V to 100 V; 0,33 A to 0,9 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,090 %"},{"name":"25 V to 100 V; 0,9 A to 2,2 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,070 %"},{"name":"25 V to 100 V; 2,2 A to 4,5 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,13 %"},{"name":"25 V to 100 V; 4,5 A to 11 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,10 %"},{"name":"25 V to 100 V; 11 A to 20 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,092 %"},{"name":"25 V to 100 V; 20 A to 30 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,075 %"},{"name":"25 V to 100 V; 30 A to 60 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,092 %"},{"name":"25 V to 100 V; 60 A to 90 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,075 %"},{"name":"100 V to 280 V; 3,3 mA to 9 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"100 V to 280 V; 9 mA to 33 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"100 V to 280 V; 33 mA to 90 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"100 V to 280 V; 90 mA to 330 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"100 V to 280 V; 0,33 A to 0,9 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,090 %"},{"name":"100 V to 280 V; 0,9 A to 2,2 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,070 %"},{"name":"100 V to 280 V; 2,2 A to 4,5 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,13 %"},{"name":"100 V to 280 V; 4,5 A to 11 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,10 %"},{"name":"100 V to 280 V; 11 A to 20 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,089 %"},{"name":"100 V to 280 V; 20 A to 30 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,073 %"},{"name":"100 V to 280 V; 30 A to 60 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,089 %"},{"name":"100 V to 280 V; 60 A to 90 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,073 %"},{"name":"280 V to 1000 V; 3,3 mA to 9 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"280 V to 1000 V; 9 mA to 33 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"280 V to 1000 V; 33 mA to 90 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,055 %"},{"name":"280 V to 1000 V; 90 mA to 330 mA","range":"0,66 Ws to 2,177 GWs","cmc":"0,050 %"},{"name":"280 V to 1000 V; 0,33 A to 0,9 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,090 %"},{"name":"280 V to 1000 V; 0,9 A to 2,2 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,070 %"},{"name":"280 V to 1000 V; 2,2 A to 4,5 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,13 %"},{"name":"280 V to 1000 V; 4,5 A to 11 A","range":"0,66 Ws to 2,177 GWs","cmc":"0,10 %"}],"parameters_zh":[{"name":"33 mV 至 25 V；3,3 mA 至 9 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV 至 25 V；9 mA 至 33 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV 至 25 V；33 mA 至 90 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV 至 25 V；90 mA 至 330 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV 至 25 V；0,33 A 至 0,9 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,090 %"},{"name":"33 mV 至 25 V；0,9 A 至 2,2 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,070 %"},{"name":"33 mV 至 25 V；2,2 A 至 4,5 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,13 %"},{"name":"33 mV 至 25 V；4,5 A 至 11 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,10 %"},{"name":"33 mV 至 25 V；11 A 至 20 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV 至 25 V；20 A 至 30 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,079 %"},{"name":"33 mV 至 25 V；30 A 至 60 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV 至 25 V；60 A 至 90 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,079 %"},{"name":"25 V 至 100 V；3,3 mA 至 9 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"25 V 至 100 V；9 mA 至 33 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"25 V 至 100 V；33 mA 至 50 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"25 V 至 100 V；50 mA 至 100 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,040 %"},{"name":"25 V 至 100 V；100 mA 至 330 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"25 V 至 100 V；0,33 A 至 0,9 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,090 %"},{"name":"25 V 至 100 V；0,9 A 至 2,2 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,070 %"},{"name":"25 V 至 100 V；2,2 A 至 4,5 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,13 %"},{"name":"25 V 至 100 V；4,5 A 至 11 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,10 %"},{"name":"25 V 至 100 V；11 A 至 20 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,092 %"},{"name":"25 V 至 100 V；20 A 至 30 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,075 %"},{"name":"25 V 至 100 V；30 A 至 60 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,092 %"},{"name":"25 V 至 100 V；60 A 至 90 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,075 %"},{"name":"100 V 至 280 V；3,3 mA 至 9 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"100 V 至 280 V；9 mA 至 33 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"100 V 至 280 V；33 mA 至 90 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"100 V 至 280 V；90 mA 至 330 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"100 V 至 280 V；0,33 A 至 0,9 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,090 %"},{"name":"100 V 至 280 V；0,9 A 至 2,2 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,070 %"},{"name":"100 V 至 280 V；2,2 A 至 4,5 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,13 %"},{"name":"100 V 至 280 V；4,5 A 至 11 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,10 %"},{"name":"100 V 至 280 V；11 A 至 20 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,089 %"},{"name":"100 V 至 280 V；20 A 至 30 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,073 %"},{"name":"100 V 至 280 V；30 A 至 60 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,089 %"},{"name":"100 V 至 280 V；60 A 至 90 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,073 %"},{"name":"280 V 至 1000 V；3,3 mA 至 9 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"280 V 至 1000 V；9 mA 至 33 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"280 V 至 1000 V；33 mA 至 90 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,055 %"},{"name":"280 V 至 1000 V；90 mA 至 330 mA","range":"0,66 Ws 至 2,177 GWs","cmc":"0,050 %"},{"name":"280 V 至 1000 V；0,33 A 至 0,9 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,090 %"},{"name":"280 V 至 1000 V；0,9 A 至 2,2 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,070 %"},{"name":"280 V 至 1000 V；2,2 A 至 4,5 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,13 %"},{"name":"280 V 至 1000 V；4,5 A 至 11 A","range":"0,66 Ws 至 2,177 GWs","cmc":"0,10 %"}],"parameters_cs":[{"name":"33 mV až 25 V; 3,3 mA až 9 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV až 25 V; 9 mA až 33 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV až 25 V; 33 mA až 90 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"33 mV až 25 V; 90 mA až 330 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"33 mV až 25 V; 0,33 A až 0,9 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,090 %"},{"name":"33 mV až 25 V; 0,9 A až 2,2 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,070 %"},{"name":"33 mV až 25 V; 2,2 A až 4,5 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,13 %"},{"name":"33 mV až 25 V; 4,5 A až 11 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,10 %"},{"name":"33 mV až 25 V; 11 A až 20 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV až 25 V; 20 A až 30 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,079 %"},{"name":"33 mV až 25 V; 30 A až 60 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,096 %"},{"name":"33 mV až 25 V; 60 A až 90 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,079 %"},{"name":"25 V až 100 V; 3,3 mA až 9 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"25 V až 100 V; 9 mA až 33 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"25 V až 100 V; 33 mA až 50 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"25 V až 100 V; 50 mA až 100 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,040 %"},{"name":"25 V až 100 V; 100 mA až 330 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"25 V až 100 V; 0,33 A až 0,9 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,090 %"},{"name":"25 V až 100 V; 0,9 A až 2,2 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,070 %"},{"name":"25 V až 100 V; 2,2 A až 4,5 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,13 %"},{"name":"25 V až 100 V; 4,5 A až 11 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,10 %"},{"name":"25 V až 100 V; 11 A až 20 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,092 %"},{"name":"25 V až 100 V; 20 A až 30 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,075 %"},{"name":"25 V až 100 V; 30 A až 60 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,092 %"},{"name":"25 V až 100 V; 60 A až 90 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,075 %"},{"name":"100 V až 280 V; 3,3 mA až 9 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"100 V až 280 V; 9 mA až 33 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"100 V až 280 V; 33 mA až 90 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"100 V až 280 V; 90 mA až 330 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"100 V až 280 V; 0,33 A až 0,9 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,090 %"},{"name":"100 V až 280 V; 0,9 A až 2,2 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,070 %"},{"name":"100 V až 280 V; 2,2 A až 4,5 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,13 %"},{"name":"100 V až 280 V; 4,5 A až 11 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,10 %"},{"name":"100 V až 280 V; 11 A až 20 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,089 %"},{"name":"100 V až 280 V; 20 A až 30 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,073 %"},{"name":"100 V až 280 V; 30 A až 60 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,089 %"},{"name":"100 V až 280 V; 60 A až 90 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,073 %"},{"name":"280 V až 1000 V; 3,3 mA až 9 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"280 V až 1000 V; 9 mA až 33 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"280 V až 1000 V; 33 mA až 90 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,055 %"},{"name":"280 V až 1000 V; 90 mA až 330 mA","range":"0,66 Ws až 2,177 GWs","cmc":"0,050 %"},{"name":"280 V až 1000 V; 0,33 A až 0,9 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,090 %"},{"name":"280 V až 1000 V; 0,9 A až 2,2 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,070 %"},{"name":"280 V až 1000 V; 2,2 A až 4,5 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,13 %"},{"name":"280 V až 1000 V; 4,5 A až 11 A","range":"0,66 Ws až 2,177 GWs","cmc":"0,10 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n33 mV do 25 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n33 mV do 25 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n33 mV do 25 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n33 mV do 25 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n33 mV do 25 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 %\n33 mV do 25 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 %\n33 mV do 25 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 %\n33 mV do 25 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 %\n33 mV do 25 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,096 %\n33 mV do 25 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,079 %\n33 mV do 25 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,096 %\n33 mV do 25 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,079 %\n25 V do 100 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n25 V do 100 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n25 V do 100 V; 33 mA do 50 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n25 V do 100 V; 50 mA do 100 mA od 0,66 Ws do 2,177 GWs CMC 0,040 %\n25 V do 100 V; 100 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n25 V do 100 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 %\n25 V do 100 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 %\n25 V do 100 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 %\n25 V do 100 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 %\n25 V do 100 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,092 %\n25 V do 100 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,075 %\n25 V do 100 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,092 %\n25 V do 100 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,075 %\n100 V do 280 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n100 V do 280 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n100 V do 280 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n100 V do 280 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n100 V do 280 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 %\n100 V do 280 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 %\n100 V do 280 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 %\n100 V do 280 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 %\n100 V do 280 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,089 %\n100 V do 280 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,073 %\n100 V do 280 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,089 %\n100 V do 280 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,073 %\n280 V do 1000 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n280 V do 1000 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n280 V do 1000 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 %\n280 V do 1000 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 %\n280 V do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 %\n280 V do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 %\n280 V do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 %\n280 V do 1000 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu stałego / Liczniki energii elektrycznej prądu stałego (t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 33 mV do 25 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 33 mV do 25 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 33 mV do 25 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 33 mV do 25 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 33 mV do 25 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 33 mV do 25 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 33 mV do 25 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 33 mV do 25 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % 33 mV do 25 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,096 % 33 mV do 25 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,079 % 33 mV do 25 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,096 % 33 mV do 25 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,079 % 25 V do 100 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 25 V do 100 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 25 V do 100 V; 33 mA do 50 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 25 V do 100 V; 50 mA do 100 mA od 0,66 Ws do 2,177 GWs CMC 0,040 % 25 V do 100 V; 100 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 25 V do 100 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 25 V do 100 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 25 V do 100 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 25 V do 100 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % 25 V do 100 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,092 % 25 V do 100 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,075 % 25 V do 100 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,092 % 25 V do 100 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,075 % 100 V do 280 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 100 V do 280 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 100 V do 280 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 100 V do 280 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 100 V do 280 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 100 V do 280 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 100 V do 280 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 100 V do 280 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % 100 V do 280 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,089 % 100 V do 280 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,073 % 100 V do 280 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,089 % 100 V do 280 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,073 % 280 V do 1000 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 280 V do 1000 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 280 V do 1000 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 280 V do 1000 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 280 V do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 280 V do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 280 V do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 280 V do 1000 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % Stejnosměrná elektrická práce / Stejnosměrná měřidla elektrické práce (t: 600 s až 24 h) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 33 mV až 25 V; 3,3 mA až 9 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 33 mV až 25 V; 9 mA až 33 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 33 mV až 25 V; 33 mA až 90 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 33 mV až 25 V; 90 mA až 330 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 33 mV až 25 V; 0,33 A až 0,9 A 0,66 Ws až 2,177 GWs CMC 0,090 % 33 mV až 25 V; 0,9 A až 2,2 A 0,66 Ws až 2,177 GWs CMC 0,070 % 33 mV až 25 V; 2,2 A až 4,5 A 0,66 Ws až 2,177 GWs CMC 0,13 % 33 mV až 25 V; 4,5 A až 11 A 0,66 Ws až 2,177 GWs CMC 0,10 % 33 mV až 25 V; 11 A až 20 A 0,66 Ws až 2,177 GWs CMC 0,096 % 33 mV až 25 V; 20 A až 30 A 0,66 Ws až 2,177 GWs CMC 0,079 % 33 mV až 25 V; 30 A až 60 A 0,66 Ws až 2,177 GWs CMC 0,096 % 33 mV až 25 V; 60 A až 90 A 0,66 Ws až 2,177 GWs CMC 0,079 % 25 V až 100 V; 3,3 mA až 9 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 25 V až 100 V; 9 mA až 33 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 25 V až 100 V; 33 mA až 50 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 25 V až 100 V; 50 mA až 100 mA 0,66 Ws až 2,177 GWs CMC 0,040 % 25 V až 100 V; 100 mA až 330 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 25 V až 100 V; 0,33 A až 0,9 A 0,66 Ws až 2,177 GWs CMC 0,090 % 25 V až 100 V; 0,9 A až 2,2 A 0,66 Ws až 2,177 GWs CMC 0,070 % 25 V až 100 V; 2,2 A až 4,5 A 0,66 Ws až 2,177 GWs CMC 0,13 % 25 V až 100 V; 4,5 A až 11 A 0,66 Ws až 2,177 GWs CMC 0,10 % 25 V až 100 V; 11 A až 20 A 0,66 Ws až 2,177 GWs CMC 0,092 % 25 V až 100 V; 20 A až 30 A 0,66 Ws až 2,177 GWs CMC 0,075 % 25 V až 100 V; 30 A až 60 A 0,66 Ws až 2,177 GWs CMC 0,092 % 25 V až 100 V; 60 A až 90 A 0,66 Ws až 2,177 GWs CMC 0,075 % 100 V až 280 V; 3,3 mA až 9 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 100 V až 280 V; 9 mA až 33 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 100 V až 280 V; 33 mA až 90 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 100 V až 280 V; 90 mA až 330 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 100 V až 280 V; 0,33 A až 0,9 A 0,66 Ws až 2,177 GWs CMC 0,090 % 100 V až 280 V; 0,9 A až 2,2 A 0,66 Ws až 2,177 GWs CMC 0,070 % 100 V až 280 V; 2,2 A až 4,5 A 0,66 Ws až 2,177 GWs CMC 0,13 % 100 V až 280 V; 4,5 A až 11 A 0,66 Ws až 2,177 GWs CMC 0,10 % 100 V až 280 V; 11 A až 20 A 0,66 Ws až 2,177 GWs CMC 0,089 % 100 V až 280 V; 20 A až 30 A 0,66 Ws až 2,177 GWs CMC 0,073 % 100 V až 280 V; 30 A až 60 A 0,66 Ws až 2,177 GWs CMC 0,089 % 100 V až 280 V; 60 A až 90 A 0,66 Ws až 2,177 GWs CMC 0,073 % 280 V až 1000 V; 3,3 mA až 9 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 280 V až 1000 V; 9 mA až 33 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 280 V až 1000 V; 33 mA až 90 mA 0,66 Ws až 2,177 GWs CMC 0,055 % 280 V až 1000 V; 90 mA až 330 mA 0,66 Ws až 2,177 GWs CMC 0,050 % 280 V až 1000 V; 0,33 A až 0,9 A 0,66 Ws až 2,177 GWs CMC 0,090 % 280 V až 1000 V; 0,9 A až 2,2 A 0,66 Ws až 2,177 GWs CMC 0,070 % 280 V až 1000 V; 2,2 A až 4,5 A 0,66 Ws až 2,177 GWs CMC 0,13 % 280 V až 1000 V; 4,5 A až 11 A 0,66 Ws až 2,177 GWs CMC 0,10 % TP16 Energia elektryczna pradu stalego / Liczniki energii elektrycznej pradu stalego (t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 33 mV do 25 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 33 mV do 25 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 33 mV do 25 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 33 mV do 25 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 33 mV do 25 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 33 mV do 25 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 33 mV do 25 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 33 mV do 25 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % 33 mV do 25 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,096 % 33 mV do 25 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,079 % 33 mV do 25 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,096 % 33 mV do 25 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,079 % 25 V do 100 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 25 V do 100 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 25 V do 100 V; 33 mA do 50 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 25 V do 100 V; 50 mA do 100 mA od 0,66 Ws do 2,177 GWs CMC 0,040 % 25 V do 100 V; 100 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 25 V do 100 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 25 V do 100 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 25 V do 100 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 25 V do 100 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % 25 V do 100 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,092 % 25 V do 100 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,075 % 25 V do 100 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,092 % 25 V do 100 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,075 % 100 V do 280 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 100 V do 280 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 100 V do 280 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 100 V do 280 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 100 V do 280 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 100 V do 280 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 100 V do 280 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 100 V do 280 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % 100 V do 280 V; 11 A do 20 A od 0,66 Ws do 2,177 GWs CMC 0,089 % 100 V do 280 V; 20 A do 30 A od 0,66 Ws do 2,177 GWs CMC 0,073 % 100 V do 280 V; 30 A do 60 A od 0,66 Ws do 2,177 GWs CMC 0,089 % 100 V do 280 V; 60 A do 90 A od 0,66 Ws do 2,177 GWs CMC 0,073 % 280 V do 1000 V; 3,3 mA do 9 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 280 V do 1000 V; 9 mA do 33 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 280 V do 1000 V; 33 mA do 90 mA od 0,66 Ws do 2,177 GWs CMC 0,055 % 280 V do 1000 V; 90 mA do 330 mA od 0,66 Ws do 2,177 GWs CMC 0,050 % 280 V do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 2,177 GWs CMC 0,090 % 280 V do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 2,177 GWs CMC 0,070 % 280 V do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 2,177 GWs CMC 0,13 % 280 V do 1000 V; 4,5 A do 11 A od 0,66 Ws do 2,177 GWs CMC 0,10 % Stejnosmerna elektricka prace / Stejnosmerna meridla elektricke prace (t: 600 s az 24 h) Kalibrace – elektricke veliciny Prime generovani kalibratorem 33 mV az 25 V; 3,3 mA az 9 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 33 mV az 25 V; 9 mA az 33 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 33 mV az 25 V; 33 mA az 90 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 33 mV az 25 V; 90 mA az 330 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 33 mV az 25 V; 0,33 A az 0,9 A 0,66 Ws az 2,177 GWs CMC 0,090 % 33 mV az 25 V; 0,9 A az 2,2 A 0,66 Ws az 2,177 GWs CMC 0,070 % 33 mV az 25 V; 2,2 A az 4,5 A 0,66 Ws az 2,177 GWs CMC 0,13 % 33 mV az 25 V; 4,5 A az 11 A 0,66 Ws az 2,177 GWs CMC 0,10 % 33 mV az 25 V; 11 A az 20 A 0,66 Ws az 2,177 GWs CMC 0,096 % 33 mV az 25 V; 20 A az 30 A 0,66 Ws az 2,177 GWs CMC 0,079 % 33 mV az 25 V; 30 A az 60 A 0,66 Ws az 2,177 GWs CMC 0,096 % 33 mV az 25 V; 60 A az 90 A 0,66 Ws az 2,177 GWs CMC 0,079 % 25 V az 100 V; 3,3 mA az 9 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 25 V az 100 V; 9 mA az 33 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 25 V az 100 V; 33 mA az 50 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 25 V az 100 V; 50 mA az 100 mA 0,66 Ws az 2,177 GWs CMC 0,040 % 25 V az 100 V; 100 mA az 330 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 25 V az 100 V; 0,33 A az 0,9 A 0,66 Ws az 2,177 GWs CMC 0,090 % 25 V az 100 V; 0,9 A az 2,2 A 0,66 Ws az 2,177 GWs CMC 0,070 % 25 V az 100 V; 2,2 A az 4,5 A 0,66 Ws az 2,177 GWs CMC 0,13 % 25 V az 100 V; 4,5 A az 11 A 0,66 Ws az 2,177 GWs CMC 0,10 % 25 V az 100 V; 11 A az 20 A 0,66 Ws az 2,177 GWs CMC 0,092 % 25 V az 100 V; 20 A az 30 A 0,66 Ws az 2,177 GWs CMC 0,075 % 25 V az 100 V; 30 A az 60 A 0,66 Ws az 2,177 GWs CMC 0,092 % 25 V az 100 V; 60 A az 90 A 0,66 Ws az 2,177 GWs CMC 0,075 % 100 V az 280 V; 3,3 mA az 9 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 100 V az 280 V; 9 mA az 33 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 100 V az 280 V; 33 mA az 90 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 100 V az 280 V; 90 mA az 330 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 100 V az 280 V; 0,33 A az 0,9 A 0,66 Ws az 2,177 GWs CMC 0,090 % 100 V az 280 V; 0,9 A az 2,2 A 0,66 Ws az 2,177 GWs CMC 0,070 % 100 V az 280 V; 2,2 A az 4,5 A 0,66 Ws az 2,177 GWs CMC 0,13 % 100 V az 280 V; 4,5 A az 11 A 0,66 Ws az 2,177 GWs CMC 0,10 % 100 V az 280 V; 11 A az 20 A 0,66 Ws az 2,177 GWs CMC 0,089 % 100 V az 280 V; 20 A az 30 A 0,66 Ws az 2,177 GWs CMC 0,073 % 100 V az 280 V; 30 A az 60 A 0,66 Ws az 2,177 GWs CMC 0,089 % 100 V az 280 V; 60 A az 90 A 0,66 Ws az 2,177 GWs CMC 0,073 % 280 V az 1000 V; 3,3 mA az 9 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 280 V az 1000 V; 9 mA az 33 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 280 V az 1000 V; 33 mA az 90 mA 0,66 Ws az 2,177 GWs CMC 0,055 % 280 V az 1000 V; 90 mA az 330 mA 0,66 Ws az 2,177 GWs CMC 0,050 % 280 V az 1000 V; 0,33 A az 0,9 A 0,66 Ws az 2,177 GWs CMC 0,090 % 280 V az 1000 V; 0,9 A az 2,2 A 0,66 Ws az 2,177 GWs CMC 0,070 % 280 V az 1000 V; 2,2 A az 4,5 A 0,66 Ws az 2,177 GWs CMC 0,13 % 280 V az 1000 V; 4,5 A az 11 A 0,66 Ws az 2,177 GWs CMC 0,10 % TP16","search_en":"DC electrical work / DC electrical work meters (t: 600 s to 24 h) Calibration – electrical quantities Direct generation with a calibrator 33 mV to 25 V; 3,3 mA to 9 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 33 mV to 25 V; 9 mA to 33 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 33 mV to 25 V; 33 mA to 90 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 33 mV to 25 V; 90 mA to 330 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 33 mV to 25 V; 0,33 A to 0,9 A 0,66 Ws to 2,177 GWs CMC 0,090 % 33 mV to 25 V; 0,9 A to 2,2 A 0,66 Ws to 2,177 GWs CMC 0,070 % 33 mV to 25 V; 2,2 A to 4,5 A 0,66 Ws to 2,177 GWs CMC 0,13 % 33 mV to 25 V; 4,5 A to 11 A 0,66 Ws to 2,177 GWs CMC 0,10 % 33 mV to 25 V; 11 A to 20 A 0,66 Ws to 2,177 GWs CMC 0,096 % 33 mV to 25 V; 20 A to 30 A 0,66 Ws to 2,177 GWs CMC 0,079 % 33 mV to 25 V; 30 A to 60 A 0,66 Ws to 2,177 GWs CMC 0,096 % 33 mV to 25 V; 60 A to 90 A 0,66 Ws to 2,177 GWs CMC 0,079 % 25 V to 100 V; 3,3 mA to 9 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 25 V to 100 V; 9 mA to 33 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 25 V to 100 V; 33 mA to 50 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 25 V to 100 V; 50 mA to 100 mA 0,66 Ws to 2,177 GWs CMC 0,040 % 25 V to 100 V; 100 mA to 330 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 25 V to 100 V; 0,33 A to 0,9 A 0,66 Ws to 2,177 GWs CMC 0,090 % 25 V to 100 V; 0,9 A to 2,2 A 0,66 Ws to 2,177 GWs CMC 0,070 % 25 V to 100 V; 2,2 A to 4,5 A 0,66 Ws to 2,177 GWs CMC 0,13 % 25 V to 100 V; 4,5 A to 11 A 0,66 Ws to 2,177 GWs CMC 0,10 % 25 V to 100 V; 11 A to 20 A 0,66 Ws to 2,177 GWs CMC 0,092 % 25 V to 100 V; 20 A to 30 A 0,66 Ws to 2,177 GWs CMC 0,075 % 25 V to 100 V; 30 A to 60 A 0,66 Ws to 2,177 GWs CMC 0,092 % 25 V to 100 V; 60 A to 90 A 0,66 Ws to 2,177 GWs CMC 0,075 % 100 V to 280 V; 3,3 mA to 9 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 100 V to 280 V; 9 mA to 33 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 100 V to 280 V; 33 mA to 90 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 100 V to 280 V; 90 mA to 330 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 100 V to 280 V; 0,33 A to 0,9 A 0,66 Ws to 2,177 GWs CMC 0,090 % 100 V to 280 V; 0,9 A to 2,2 A 0,66 Ws to 2,177 GWs CMC 0,070 % 100 V to 280 V; 2,2 A to 4,5 A 0,66 Ws to 2,177 GWs CMC 0,13 % 100 V to 280 V; 4,5 A to 11 A 0,66 Ws to 2,177 GWs CMC 0,10 % 100 V to 280 V; 11 A to 20 A 0,66 Ws to 2,177 GWs CMC 0,089 % 100 V to 280 V; 20 A to 30 A 0,66 Ws to 2,177 GWs CMC 0,073 % 100 V to 280 V; 30 A to 60 A 0,66 Ws to 2,177 GWs CMC 0,089 % 100 V to 280 V; 60 A to 90 A 0,66 Ws to 2,177 GWs CMC 0,073 % 280 V to 1000 V; 3,3 mA to 9 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 280 V to 1000 V; 9 mA to 33 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 280 V to 1000 V; 33 mA to 90 mA 0,66 Ws to 2,177 GWs CMC 0,055 % 280 V to 1000 V; 90 mA to 330 mA 0,66 Ws to 2,177 GWs CMC 0,050 % 280 V to 1000 V; 0,33 A to 0,9 A 0,66 Ws to 2,177 GWs CMC 0,090 % 280 V to 1000 V; 0,9 A to 2,2 A 0,66 Ws to 2,177 GWs CMC 0,070 % 280 V to 1000 V; 2,2 A to 4,5 A 0,66 Ws to 2,177 GWs CMC 0,13 % 280 V to 1000 V; 4,5 A to 11 A 0,66 Ws to 2,177 GWs CMC 0,10 % TP16","search_zh":"直流电能 / 直流电能表（t：600 s 至 24 h） 校准 – 电学量 用校准器直接产生 33 mV 至 25 V；3,3 mA 至 9 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 33 mV 至 25 V；9 mA 至 33 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 33 mV 至 25 V；33 mA 至 90 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 33 mV 至 25 V；90 mA 至 330 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 33 mV 至 25 V；0,33 A 至 0,9 A 0,66 Ws 至 2,177 GWs CMC 0,090 % 33 mV 至 25 V；0,9 A 至 2,2 A 0,66 Ws 至 2,177 GWs CMC 0,070 % 33 mV 至 25 V；2,2 A 至 4,5 A 0,66 Ws 至 2,177 GWs CMC 0,13 % 33 mV 至 25 V；4,5 A 至 11 A 0,66 Ws 至 2,177 GWs CMC 0,10 % 33 mV 至 25 V；11 A 至 20 A 0,66 Ws 至 2,177 GWs CMC 0,096 % 33 mV 至 25 V；20 A 至 30 A 0,66 Ws 至 2,177 GWs CMC 0,079 % 33 mV 至 25 V；30 A 至 60 A 0,66 Ws 至 2,177 GWs CMC 0,096 % 33 mV 至 25 V；60 A 至 90 A 0,66 Ws 至 2,177 GWs CMC 0,079 % 25 V 至 100 V；3,3 mA 至 9 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 25 V 至 100 V；9 mA 至 33 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 25 V 至 100 V；33 mA 至 50 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 25 V 至 100 V；50 mA 至 100 mA 0,66 Ws 至 2,177 GWs CMC 0,040 % 25 V 至 100 V；100 mA 至 330 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 25 V 至 100 V；0,33 A 至 0,9 A 0,66 Ws 至 2,177 GWs CMC 0,090 % 25 V 至 100 V；0,9 A 至 2,2 A 0,66 Ws 至 2,177 GWs CMC 0,070 % 25 V 至 100 V；2,2 A 至 4,5 A 0,66 Ws 至 2,177 GWs CMC 0,13 % 25 V 至 100 V；4,5 A 至 11 A 0,66 Ws 至 2,177 GWs CMC 0,10 % 25 V 至 100 V；11 A 至 20 A 0,66 Ws 至 2,177 GWs CMC 0,092 % 25 V 至 100 V；20 A 至 30 A 0,66 Ws 至 2,177 GWs CMC 0,075 % 25 V 至 100 V；30 A 至 60 A 0,66 Ws 至 2,177 GWs CMC 0,092 % 25 V 至 100 V；60 A 至 90 A 0,66 Ws 至 2,177 GWs CMC 0,075 % 100 V 至 280 V；3,3 mA 至 9 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 100 V 至 280 V；9 mA 至 33 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 100 V 至 280 V；33 mA 至 90 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 100 V 至 280 V；90 mA 至 330 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 100 V 至 280 V；0,33 A 至 0,9 A 0,66 Ws 至 2,177 GWs CMC 0,090 % 100 V 至 280 V；0,9 A 至 2,2 A 0,66 Ws 至 2,177 GWs CMC 0,070 % 100 V 至 280 V；2,2 A 至 4,5 A 0,66 Ws 至 2,177 GWs CMC 0,13 % 100 V 至 280 V；4,5 A 至 11 A 0,66 Ws 至 2,177 GWs CMC 0,10 % 100 V 至 280 V；11 A 至 20 A 0,66 Ws 至 2,177 GWs CMC 0,089 % 100 V 至 280 V；20 A 至 30 A 0,66 Ws 至 2,177 GWs CMC 0,073 % 100 V 至 280 V；30 A 至 60 A 0,66 Ws 至 2,177 GWs CMC 0,089 % 100 V 至 280 V；60 A 至 90 A 0,66 Ws 至 2,177 GWs CMC 0,073 % 280 V 至 1000 V；3,3 mA 至 9 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 280 V 至 1000 V；9 mA 至 33 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 280 V 至 1000 V；33 mA 至 90 mA 0,66 Ws 至 2,177 GWs CMC 0,055 % 280 V 至 1000 V；90 mA 至 330 mA 0,66 Ws 至 2,177 GWs CMC 0,050 % 280 V 至 1000 V；0,33 A 至 0,9 A 0,66 Ws 至 2,177 GWs CMC 0,090 % 280 V 至 1000 V；0,9 A 至 2,2 A 0,66 Ws 至 2,177 GWs CMC 0,070 % 280 V 至 1000 V；2,2 A 至 4,5 A 0,66 Ws 至 2,177 GWs CMC 0,13 % 280 V 至 1000 V；4,5 A 至 11 A 0,66 Ws 至 2,177 GWs CMC 0,10 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"615038bd4a88423e5d2d2bb0","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"21","test_object":"Energia elektryczna prądu stałego / Liczniki energii elektrycznej prądu stałego z cęgowymi czujnikami prądu (t: 600 s do 24 h)","test_object_en":"DC electrical work / DC electrical work meters with clamp current sensors (t: 600 s to 24 h)","test_object_zh":"直流电能 / 带钳形电流传感器的直流电能表（t：600 s 至 24 h）","test_object_cs":"Stejnosměrná elektrická práce / Stejnosměrná měřidla elektrické práce s klešťovými snímači proudu (t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"33 mV do 1000 V; 10 A do 2250 A","range":"od 6 kWs do 54,43 GWs","cmc":"0,55 %"}],"parameters_en":[{"name":"33 mV to 1000 V; 10 A to 2250 A","range":"6 kWs to 54,43 GWs","cmc":"0,55 %"}],"parameters_zh":[{"name":"33 mV 至 1000 V；10 A 至 2250 A","range":"6 kWs 至 54,43 GWs","cmc":"0,55 %"}],"parameters_cs":[{"name":"33 mV až 1000 V; 10 A až 2250 A","range":"6 kWs až 54,43 GWs","cmc":"0,55 %"}],"technique":"Pośrednie generowanie kalibratorem z cewką prądową","technique_en":"Indirect generation with a calibrator with a current coil","technique_zh":"用带电流线圈的校准器间接产生","technique_cs":"Nepřímé generování kalibrátorem s proudovou cívkou","techniques":["Pośrednie generowanie kalibratorem z cewką prądową"],"techniques_en":["Indirect generation with a calibrator with a current coil"],"techniques_zh":["用带电流线圈的校准器间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n33 mV do 1000 V; 10 A do 2250 A od 6 kWs do 54,43 GWs CMC 0,55 %\nPośrednie generowanie kalibratorem z cewką prądową","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu stałego / Liczniki energii elektrycznej prądu stałego z cęgowymi czujnikami prądu (t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z cewką prądową 33 mV do 1000 V; 10 A do 2250 A od 6 kWs do 54,43 GWs CMC 0,55 % Stejnosměrná elektrická práce / Stejnosměrná měřidla elektrické práce s klešťovými snímači proudu (t: 600 s až 24 h) Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem s proudovou cívkou 33 mV až 1000 V; 10 A až 2250 A 6 kWs až 54,43 GWs CMC 0,55 % TP16 Energia elektryczna pradu stalego / Liczniki energii elektrycznej pradu stalego z cegowymi czujnikami pradu (t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z cewka pradowa 33 mV do 1000 V; 10 A do 2250 A od 6 kWs do 54,43 GWs CMC 0,55 % Stejnosmerna elektricka prace / Stejnosmerna meridla elektricke prace s klestovymi snimaci proudu (t: 600 s az 24 h) Kalibrace – elektricke veliciny Neprime generovani kalibratorem s proudovou civkou 33 mV az 1000 V; 10 A az 2250 A 6 kWs az 54,43 GWs CMC 0,55 % TP16","search_en":"DC electrical work / DC electrical work meters with clamp current sensors (t: 600 s to 24 h) Calibration – electrical quantities Indirect generation with a calibrator with a current coil 33 mV to 1000 V; 10 A to 2250 A 6 kWs to 54,43 GWs CMC 0,55 % TP16","search_zh":"直流电能 / 带钳形电流传感器的直流电能表（t：600 s 至 24 h） 校准 – 电学量 用带电流线圈的校准器间接产生 33 mV 至 1000 V；10 A 至 2250 A 6 kWs 至 54,43 GWs CMC 0,55 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc5b011bd873d5562871e912","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"21","test_object":"Energia elektryczna prądu stałego / Specjalne liczniki energii elektrycznej z wejściami prądowymi (t: 600 s do 24 h)","test_object_en":"DC electrical work / Special electrical work meters with current inputs (t: 600 s to 24 h)","test_object_zh":"直流电能 / 带电流输入的专用电能表（t：600 s 至 24 h）","test_object_cs":"Stejnosměrná elektrická práce / Speciální měřidla elektrické práce s proudovými vstupy (t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"I₁: 0 µA do 2 A; I₂: 10 µA do 2 A","range":"od 0 Ws do 2,4 GWh","cmc":"0,1 % + 1 Ws"}],"parameters_en":[{"name":"I₁: 0 µA to 2 A; I₂: 10 µA to 2 A","range":"0 Ws to 2,4 GWh","cmc":"0,1 % + 1 Ws"}],"parameters_zh":[{"name":"I₁：0 µA 至 2 A；I₂：10 µA 至 2 A","range":"0 Ws 至 2,4 GWh","cmc":"0,1 % + 1 Ws"}],"parameters_cs":[{"name":"I₁: 0 µA až 2 A; I₂: 10 µA až 2 A","range":"0 Ws až 2,4 GWh","cmc":"0,1 % + 1 Ws"}],"technique":"Bezpośrednie generowanie kalibratorami","technique_en":"Direct generation with calibrators","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátory","techniques":["Bezpośrednie generowanie kalibratorami"],"techniques_en":["Direct generation with calibrators"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nI₁: 0 µA do 2 A; I₂: 10 µA do 2 A od 0 Ws do 2,4 GWh CMC 0,1 % + 1 Ws\nBezpośrednie generowanie kalibratorami","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu stałego / Specjalne liczniki energii elektrycznej z wejściami prądowymi (t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorami I₁: 0 µA do 2 A; I₂: 10 µA do 2 A od 0 Ws do 2,4 GWh CMC 0,1 % + 1 Ws Stejnosměrná elektrická práce / Speciální měřidla elektrické práce s proudovými vstupy (t: 600 s až 24 h) Kalibrace – elektrické veličiny Přímé generování kalibrátory I₁: 0 µA až 2 A; I₂: 10 µA až 2 A 0 Ws až 2,4 GWh CMC 0,1 % + 1 Ws TP16 Energia elektryczna pradu stalego / Specjalne liczniki energii elektrycznej z wejsciami pradowymi (t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorami I₁: 0 µA do 2 A; I₂: 10 µA do 2 A od 0 Ws do 2,4 GWh CMC 0,1 % + 1 Ws Stejnosmerna elektricka prace / Specialni meridla elektricke prace s proudovymi vstupy (t: 600 s az 24 h) Kalibrace – elektricke veliciny Prime generovani kalibratory I₁: 0 µA az 2 A; I₂: 10 µA az 2 A 0 Ws az 2,4 GWh CMC 0,1 % + 1 Ws TP16","search_en":"DC electrical work / Special electrical work meters with current inputs (t: 600 s to 24 h) Calibration – electrical quantities Direct generation with calibrators I₁: 0 µA to 2 A; I₂: 10 µA to 2 A 0 Ws to 2,4 GWh CMC 0,1 % + 1 Ws TP16","search_zh":"直流电能 / 带电流输入的专用电能表（t：600 s 至 24 h） 校准 – 电学量 用校准器直接产生 I₁：0 µA 至 2 A；I₂：10 µA 至 2 A 0 Ws 至 2,4 GWh CMC 0,1 % + 1 Ws TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"20f323070289f3f38c90ce2f","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"22","test_object":"Energia elektryczna prądu przemiennego jedno- i trójfazowa / Liczniki energii elektrycznej prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 1, t: 600 s do 24 h)","test_object_en":"AC electrical work, single- and three-phase / AC electrical work meters, single- and three-phase (f: 45 Hz to 65 Hz, PF = 1, t: 600 s to 24 h)","test_object_zh":"单相和三相交流电能 / 单相和三相交流电能表（f：45 Hz 至 65 Hz，PF = 1，t：600 s 至 24 h）","test_object_cs":"Střídavá elektrická práce jednofázová i třífázová / Střídavá měřidla elektrické práce jednofázová i třífázová (f: 45 Hz až 65 Hz, PF = 1, t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"330 mV do 1 V; 3,3 mA do 9 mA","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV do 1 V; 9 mA do 33 mA","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,18 %"},{"name":"330 mV do 1 V; 33 mA do 90 mA","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV do 1 V; 90 mA do 100 mA","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,18 %"},{"name":"1 V do 5 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,20 %"},{"name":"1 V do 5 V; 0,3 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,18 %"},{"name":"5 V do 10 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,15 %"},{"name":"5 V do 10 V; 0,3 A do 0,7 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,11 %"},{"name":"5 V do 10 V; 0,7 A do 1 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,09 %"},{"name":"5 V do 10 V; 1 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"10 V do 30 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,16 %"},{"name":"10 V do 30 V; 0,3 A do 10 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,11 %"},{"name":"10 V do 30 V; 10 A do 30 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,13 %"},{"name":"30 V do 50 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,16 %"},{"name":"30 V do 50 V; 0,3 A do 0,9 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,11 %"},{"name":"30 V do 50 V; 0,9 A do 1 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,09 %"},{"name":"30 V do 50 V; 1 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"50 V do 70 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,15 %"},{"name":"50 V do 70 V; 0,3 A do 0,7 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,10 %"},{"name":"50 V do 70 V; 0,7 A do 1 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,09 %"},{"name":"50 V do 70 V; 1 A do 10 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,10 %"},{"name":"50 V do 70 V; 10 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"70 V do 100 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,15 %"},{"name":"70 V do 100 V; 0,3 A do 0,7 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,11 %"},{"name":"70 V do 100 V; 0,7 A do 1 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,09 %"},{"name":"70 V do 100 V; 1 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"100 V do 140 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,15 %"},{"name":"100 V do 140 V; 0,3 A do 1 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,09 %"},{"name":"100 V do 140 V; 1 A do 10 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,10 %"},{"name":"100 V do 140 V; 10 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"140 V do 200 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,19 %"},{"name":"140 V do 200 V; 0,3 A do 0,7 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,11 %"},{"name":"140 V do 200 V; 0,7 A do 1 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,09 %"},{"name":"140 V do 200 V; 1 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"200 V do 280 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,15 %"},{"name":"200 V do 280 V; 0,3 A do 0,7 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,10 %"},{"name":"200 V do 280 V; 0,7 A do 1 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,09 %"},{"name":"200 V do 280 V; 1 A do 10 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,10 %"},{"name":"200 V do 280 V; 10 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"280 V do 400 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,16 %"},{"name":"280 V do 400 V; 0,3 A do 0,5 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,11 %"},{"name":"280 V do 400 V; 0,5 A do 5 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,10 %"},{"name":"280 V do 400 V; 5 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"400 V do 600 V; 0,1 A do 0,3 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,15 %"},{"name":"400 V do 600 V; 0,3 A do 0,5 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,11 %"},{"name":"400 V do 600 V; 0,5 A do 10 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,10 %"},{"name":"400 V do 600 V; 10 A do 90 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,12 %"},{"name":"600 V do 1000 V; 0,1 A do 0,33 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,18 %"},{"name":"600 V do 1000 V; 0,33 A do 0,9 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,28 %"},{"name":"600 V do 1000 V; 0,9 A do 2,2 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,18 %"},{"name":"600 V do 1000 V; 2,2 A do 4,5 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,23 %"},{"name":"600 V do 1000 V; 4,5 A do 11 A","range":"od 0,66 Ws do 4,665 GWs","cmc":"0,18 %"}],"parameters_en":[{"name":"330 mV to 1 V; 3,3 mA to 9 mA","range":"0,66 Ws to 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV to 1 V; 9 mA to 33 mA","range":"0,66 Ws to 4,665 GWs","cmc":"0,18 %"},{"name":"330 mV to 1 V; 33 mA to 90 mA","range":"0,66 Ws to 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV to 1 V; 90 mA to 100 mA","range":"0,66 Ws to 4,665 GWs","cmc":"0,18 %"},{"name":"1 V to 5 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,20 %"},{"name":"1 V to 5 V; 0,3 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,18 %"},{"name":"5 V to 10 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,15 %"},{"name":"5 V to 10 V; 0,3 A to 0,7 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,11 %"},{"name":"5 V to 10 V; 0,7 A to 1 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,09 %"},{"name":"5 V to 10 V; 1 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"10 V to 30 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,16 %"},{"name":"10 V to 30 V; 0,3 A to 10 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,11 %"},{"name":"10 V to 30 V; 10 A to 30 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,13 %"},{"name":"30 V to 50 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,16 %"},{"name":"30 V to 50 V; 0,3 A to 0,9 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,11 %"},{"name":"30 V to 50 V; 0,9 A to 1 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,09 %"},{"name":"30 V to 50 V; 1 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"50 V to 70 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,15 %"},{"name":"50 V to 70 V; 0,3 A to 0,7 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,10 %"},{"name":"50 V to 70 V; 0,7 A to 1 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,09 %"},{"name":"50 V to 70 V; 1 A to 10 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,10 %"},{"name":"50 V to 70 V; 10 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"70 V to 100 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,15 %"},{"name":"70 V to 100 V; 0,3 A to 0,7 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,11 %"},{"name":"70 V to 100 V; 0,7 A to 1 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,09 %"},{"name":"70 V to 100 V; 1 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"100 V to 140 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,15 %"},{"name":"100 V to 140 V; 0,3 A to 1 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,09 %"},{"name":"100 V to 140 V; 1 A to 10 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,10 %"},{"name":"100 V to 140 V; 10 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"140 V to 200 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,19 %"},{"name":"140 V to 200 V; 0,3 A to 0,7 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,11 %"},{"name":"140 V to 200 V; 0,7 A to 1 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,09 %"},{"name":"140 V to 200 V; 1 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"200 V to 280 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,15 %"},{"name":"200 V to 280 V; 0,3 A to 0,7 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,10 %"},{"name":"200 V to 280 V; 0,7 A to 1 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,09 %"},{"name":"200 V to 280 V; 1 A to 10 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,10 %"},{"name":"200 V to 280 V; 10 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"280 V to 400 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,16 %"},{"name":"280 V to 400 V; 0,3 A to 0,5 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,11 %"},{"name":"280 V to 400 V; 0,5 A to 5 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,10 %"},{"name":"280 V to 400 V; 5 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"400 V to 600 V; 0,1 A to 0,3 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,15 %"},{"name":"400 V to 600 V; 0,3 A to 0,5 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,11 %"},{"name":"400 V to 600 V; 0,5 A to 10 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,10 %"},{"name":"400 V to 600 V; 10 A to 90 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,12 %"},{"name":"600 V to 1000 V; 0,1 A to 0,33 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,18 %"},{"name":"600 V to 1000 V; 0,33 A to 0,9 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,28 %"},{"name":"600 V to 1000 V; 0,9 A to 2,2 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,18 %"},{"name":"600 V to 1000 V; 2,2 A to 4,5 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,23 %"},{"name":"600 V to 1000 V; 4,5 A to 11 A","range":"0,66 Ws to 4,665 GWs","cmc":"0,18 %"}],"parameters_zh":[{"name":"330 mV 至 1 V；3,3 mA 至 9 mA","range":"0,66 Ws 至 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV 至 1 V；9 mA 至 33 mA","range":"0,66 Ws 至 4,665 GWs","cmc":"0,18 %"},{"name":"330 mV 至 1 V；33 mA 至 90 mA","range":"0,66 Ws 至 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV 至 1 V；90 mA 至 100 mA","range":"0,66 Ws 至 4,665 GWs","cmc":"0,18 %"},{"name":"1 V 至 5 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,20 %"},{"name":"1 V 至 5 V；0,3 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,18 %"},{"name":"5 V 至 10 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,15 %"},{"name":"5 V 至 10 V；0,3 A 至 0,7 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,11 %"},{"name":"5 V 至 10 V；0,7 A 至 1 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,09 %"},{"name":"5 V 至 10 V；1 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"10 V 至 30 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,16 %"},{"name":"10 V 至 30 V；0,3 A 至 10 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,11 %"},{"name":"10 V 至 30 V；10 A 至 30 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,13 %"},{"name":"30 V 至 50 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,16 %"},{"name":"30 V 至 50 V；0,3 A 至 0,9 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,11 %"},{"name":"30 V 至 50 V；0,9 A 至 1 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,09 %"},{"name":"30 V 至 50 V；1 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"50 V 至 70 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,15 %"},{"name":"50 V 至 70 V；0,3 A 至 0,7 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,10 %"},{"name":"50 V 至 70 V；0,7 A 至 1 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,09 %"},{"name":"50 V 至 70 V；1 A 至 10 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,10 %"},{"name":"50 V 至 70 V；10 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"70 V 至 100 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,15 %"},{"name":"70 V 至 100 V；0,3 A 至 0,7 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,11 %"},{"name":"70 V 至 100 V；0,7 A 至 1 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,09 %"},{"name":"70 V 至 100 V；1 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"100 V 至 140 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,15 %"},{"name":"100 V 至 140 V；0,3 A 至 1 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,09 %"},{"name":"100 V 至 140 V；1 A 至 10 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,10 %"},{"name":"100 V 至 140 V；10 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"140 V 至 200 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,19 %"},{"name":"140 V 至 200 V；0,3 A 至 0,7 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,11 %"},{"name":"140 V 至 200 V；0,7 A 至 1 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,09 %"},{"name":"140 V 至 200 V；1 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"200 V 至 280 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,15 %"},{"name":"200 V 至 280 V；0,3 A 至 0,7 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,10 %"},{"name":"200 V 至 280 V；0,7 A 至 1 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,09 %"},{"name":"200 V 至 280 V；1 A 至 10 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,10 %"},{"name":"200 V 至 280 V；10 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"280 V 至 400 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,16 %"},{"name":"280 V 至 400 V；0,3 A 至 0,5 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,11 %"},{"name":"280 V 至 400 V；0,5 A 至 5 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,10 %"},{"name":"280 V 至 400 V；5 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"400 V 至 600 V；0,1 A 至 0,3 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,15 %"},{"name":"400 V 至 600 V；0,3 A 至 0,5 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,11 %"},{"name":"400 V 至 600 V；0,5 A 至 10 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,10 %"},{"name":"400 V 至 600 V；10 A 至 90 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,12 %"},{"name":"600 V 至 1000 V；0,1 A 至 0,33 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,18 %"},{"name":"600 V 至 1000 V；0,33 A 至 0,9 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,28 %"},{"name":"600 V 至 1000 V；0,9 A 至 2,2 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,18 %"},{"name":"600 V 至 1000 V；2,2 A 至 4,5 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,23 %"},{"name":"600 V 至 1000 V；4,5 A 至 11 A","range":"0,66 Ws 至 4,665 GWs","cmc":"0,18 %"}],"parameters_cs":[{"name":"330 mV až 1 V; 3,3 mA až 9 mA","range":"0,66 Ws až 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV až 1 V; 9 mA až 33 mA","range":"0,66 Ws až 4,665 GWs","cmc":"0,18 %"},{"name":"330 mV až 1 V; 33 mA až 90 mA","range":"0,66 Ws až 4,665 GWs","cmc":"0,28 %"},{"name":"330 mV až 1 V; 90 mA až 100 mA","range":"0,66 Ws až 4,665 GWs","cmc":"0,18 %"},{"name":"1 V až 5 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,20 %"},{"name":"1 V až 5 V; 0,3 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,18 %"},{"name":"5 V až 10 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,15 %"},{"name":"5 V až 10 V; 0,3 A až 0,7 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,11 %"},{"name":"5 V až 10 V; 0,7 A až 1 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,09 %"},{"name":"5 V až 10 V; 1 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"10 V až 30 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,16 %"},{"name":"10 V až 30 V; 0,3 A až 10 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,11 %"},{"name":"10 V až 30 V; 10 A až 30 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,13 %"},{"name":"30 V až 50 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,16 %"},{"name":"30 V až 50 V; 0,3 A až 0,9 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,11 %"},{"name":"30 V až 50 V; 0,9 A až 1 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,09 %"},{"name":"30 V až 50 V; 1 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"50 V až 70 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,15 %"},{"name":"50 V až 70 V; 0,3 A až 0,7 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,10 %"},{"name":"50 V až 70 V; 0,7 A až 1 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,09 %"},{"name":"50 V až 70 V; 1 A až 10 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,10 %"},{"name":"50 V až 70 V; 10 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"70 V až 100 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,15 %"},{"name":"70 V až 100 V; 0,3 A až 0,7 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,11 %"},{"name":"70 V až 100 V; 0,7 A až 1 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,09 %"},{"name":"70 V až 100 V; 1 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"100 V až 140 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,15 %"},{"name":"100 V až 140 V; 0,3 A až 1 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,09 %"},{"name":"100 V až 140 V; 1 A až 10 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,10 %"},{"name":"100 V až 140 V; 10 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"140 V až 200 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,19 %"},{"name":"140 V až 200 V; 0,3 A až 0,7 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,11 %"},{"name":"140 V až 200 V; 0,7 A až 1 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,09 %"},{"name":"140 V až 200 V; 1 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"200 V až 280 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,15 %"},{"name":"200 V až 280 V; 0,3 A až 0,7 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,10 %"},{"name":"200 V až 280 V; 0,7 A až 1 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,09 %"},{"name":"200 V až 280 V; 1 A až 10 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,10 %"},{"name":"200 V až 280 V; 10 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"280 V až 400 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,16 %"},{"name":"280 V až 400 V; 0,3 A až 0,5 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,11 %"},{"name":"280 V až 400 V; 0,5 A až 5 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,10 %"},{"name":"280 V až 400 V; 5 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"400 V až 600 V; 0,1 A až 0,3 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,15 %"},{"name":"400 V až 600 V; 0,3 A až 0,5 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,11 %"},{"name":"400 V až 600 V; 0,5 A až 10 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,10 %"},{"name":"400 V až 600 V; 10 A až 90 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,12 %"},{"name":"600 V až 1000 V; 0,1 A až 0,33 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,18 %"},{"name":"600 V až 1000 V; 0,33 A až 0,9 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,28 %"},{"name":"600 V až 1000 V; 0,9 A až 2,2 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,18 %"},{"name":"600 V až 1000 V; 2,2 A až 4,5 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,23 %"},{"name":"600 V až 1000 V; 4,5 A až 11 A","range":"0,66 Ws až 4,665 GWs","cmc":"0,18 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n330 mV do 1 V; 3,3 mA do 9 mA od 0,66 Ws do 4,665 GWs CMC 0,28 %\n330 mV do 1 V; 9 mA do 33 mA od 0,66 Ws do 4,665 GWs CMC 0,18 %\n330 mV do 1 V; 33 mA do 90 mA od 0,66 Ws do 4,665 GWs CMC 0,28 %\n330 mV do 1 V; 90 mA do 100 mA od 0,66 Ws do 4,665 GWs CMC 0,18 %\n1 V do 5 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,20 %\n1 V do 5 V; 0,3 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,18 %\n5 V do 10 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 %\n5 V do 10 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 %\n5 V do 10 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 %\n5 V do 10 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n10 V do 30 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 %\n10 V do 30 V; 0,3 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,11 %\n10 V do 30 V; 10 A do 30 A od 0,66 Ws do 4,665 GWs CMC 0,13 %\n30 V do 50 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 %\n30 V do 50 V; 0,3 A do 0,9 A od 0,66 Ws do 4,665 GWs CMC 0,11 %\n30 V do 50 V; 0,9 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 %\n30 V do 50 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n50 V do 70 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 %\n50 V do 70 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,10 %\n50 V do 70 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 %\n50 V do 70 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 %\n50 V do 70 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n70 V do 100 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 %\n70 V do 100 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 %\n70 V do 100 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 %\n70 V do 100 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n100 V do 140 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 %\n100 V do 140 V; 0,3 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 %\n100 V do 140 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 %\n100 V do 140 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n140 V do 200 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,19 %\n140 V do 200 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 %\n140 V do 200 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 %\n140 V do 200 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n200 V do 280 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 %\n200 V do 280 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,10 %\n200 V do 280 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 %\n200 V do 280 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 %\n200 V do 280 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n280 V do 400 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 %\n280 V do 400 V; 0,3 A do 0,5 A od 0,66 Ws do 4,665 GWs CMC 0,11 %\n280 V do 400 V; 0,5 A do 5 A od 0,66 Ws do 4,665 GWs CMC 0,10 %\n280 V do 400 V; 5 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n400 V do 600 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 %\n400 V do 600 V; 0,3 A do 0,5 A od 0,66 Ws do 4,665 GWs CMC 0,11 %\n400 V do 600 V; 0,5 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 %\n400 V do 600 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 %\n600 V do 1000 V; 0,1 A do 0,33 A od 0,66 Ws do 4,665 GWs CMC 0,18 %\n600 V do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 4,665 GWs CMC 0,28 %\n600 V do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 4,665 GWs CMC 0,18 %\n600 V do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 4,665 GWs CMC 0,23 %\n600 V do 1000 V; 4,5 A do 11 A od 0,66 Ws do 4,665 GWs CMC 0,18 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu przemiennego jedno- i trójfazowa / Liczniki energii elektrycznej prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 1, t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 330 mV do 1 V; 3,3 mA do 9 mA od 0,66 Ws do 4,665 GWs CMC 0,28 % 330 mV do 1 V; 9 mA do 33 mA od 0,66 Ws do 4,665 GWs CMC 0,18 % 330 mV do 1 V; 33 mA do 90 mA od 0,66 Ws do 4,665 GWs CMC 0,28 % 330 mV do 1 V; 90 mA do 100 mA od 0,66 Ws do 4,665 GWs CMC 0,18 % 1 V do 5 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,20 % 1 V do 5 V; 0,3 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,18 % 5 V do 10 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 5 V do 10 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 5 V do 10 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 5 V do 10 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 10 V do 30 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 % 10 V do 30 V; 0,3 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 10 V do 30 V; 10 A do 30 A od 0,66 Ws do 4,665 GWs CMC 0,13 % 30 V do 50 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 % 30 V do 50 V; 0,3 A do 0,9 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 30 V do 50 V; 0,9 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 30 V do 50 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 50 V do 70 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 50 V do 70 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 50 V do 70 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 50 V do 70 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 50 V do 70 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 70 V do 100 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 70 V do 100 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 70 V do 100 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 70 V do 100 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 100 V do 140 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 100 V do 140 V; 0,3 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 100 V do 140 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 100 V do 140 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 140 V do 200 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,19 % 140 V do 200 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 140 V do 200 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 140 V do 200 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 200 V do 280 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 200 V do 280 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 200 V do 280 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 200 V do 280 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 200 V do 280 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 280 V do 400 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 % 280 V do 400 V; 0,3 A do 0,5 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 280 V do 400 V; 0,5 A do 5 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 280 V do 400 V; 5 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 400 V do 600 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 400 V do 600 V; 0,3 A do 0,5 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 400 V do 600 V; 0,5 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 400 V do 600 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 600 V do 1000 V; 0,1 A do 0,33 A od 0,66 Ws do 4,665 GWs CMC 0,18 % 600 V do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 4,665 GWs CMC 0,28 % 600 V do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 4,665 GWs CMC 0,18 % 600 V do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 4,665 GWs CMC 0,23 % 600 V do 1000 V; 4,5 A do 11 A od 0,66 Ws do 4,665 GWs CMC 0,18 % Střídavá elektrická práce jednofázová i třífázová / Střídavá měřidla elektrické práce jednofázová i třífázová (f: 45 Hz až 65 Hz, PF = 1, t: 600 s až 24 h) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 330 mV až 1 V; 3,3 mA až 9 mA 0,66 Ws až 4,665 GWs CMC 0,28 % 330 mV až 1 V; 9 mA až 33 mA 0,66 Ws až 4,665 GWs CMC 0,18 % 330 mV až 1 V; 33 mA až 90 mA 0,66 Ws až 4,665 GWs CMC 0,28 % 330 mV až 1 V; 90 mA až 100 mA 0,66 Ws až 4,665 GWs CMC 0,18 % 1 V až 5 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,20 % 1 V až 5 V; 0,3 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,18 % 5 V až 10 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,15 % 5 V až 10 V; 0,3 A až 0,7 A 0,66 Ws až 4,665 GWs CMC 0,11 % 5 V až 10 V; 0,7 A až 1 A 0,66 Ws až 4,665 GWs CMC 0,09 % 5 V až 10 V; 1 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 10 V až 30 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,16 % 10 V až 30 V; 0,3 A až 10 A 0,66 Ws až 4,665 GWs CMC 0,11 % 10 V až 30 V; 10 A až 30 A 0,66 Ws až 4,665 GWs CMC 0,13 % 30 V až 50 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,16 % 30 V až 50 V; 0,3 A až 0,9 A 0,66 Ws až 4,665 GWs CMC 0,11 % 30 V až 50 V; 0,9 A až 1 A 0,66 Ws až 4,665 GWs CMC 0,09 % 30 V až 50 V; 1 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 50 V až 70 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,15 % 50 V až 70 V; 0,3 A až 0,7 A 0,66 Ws až 4,665 GWs CMC 0,10 % 50 V až 70 V; 0,7 A až 1 A 0,66 Ws až 4,665 GWs CMC 0,09 % 50 V až 70 V; 1 A až 10 A 0,66 Ws až 4,665 GWs CMC 0,10 % 50 V až 70 V; 10 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 70 V až 100 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,15 % 70 V až 100 V; 0,3 A až 0,7 A 0,66 Ws až 4,665 GWs CMC 0,11 % 70 V až 100 V; 0,7 A až 1 A 0,66 Ws až 4,665 GWs CMC 0,09 % 70 V až 100 V; 1 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 100 V až 140 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,15 % 100 V až 140 V; 0,3 A až 1 A 0,66 Ws až 4,665 GWs CMC 0,09 % 100 V až 140 V; 1 A až 10 A 0,66 Ws až 4,665 GWs CMC 0,10 % 100 V až 140 V; 10 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 140 V až 200 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,19 % 140 V až 200 V; 0,3 A až 0,7 A 0,66 Ws až 4,665 GWs CMC 0,11 % 140 V až 200 V; 0,7 A až 1 A 0,66 Ws až 4,665 GWs CMC 0,09 % 140 V až 200 V; 1 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 200 V až 280 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,15 % 200 V až 280 V; 0,3 A až 0,7 A 0,66 Ws až 4,665 GWs CMC 0,10 % 200 V až 280 V; 0,7 A až 1 A 0,66 Ws až 4,665 GWs CMC 0,09 % 200 V až 280 V; 1 A až 10 A 0,66 Ws až 4,665 GWs CMC 0,10 % 200 V až 280 V; 10 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 280 V až 400 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,16 % 280 V až 400 V; 0,3 A až 0,5 A 0,66 Ws až 4,665 GWs CMC 0,11 % 280 V až 400 V; 0,5 A až 5 A 0,66 Ws až 4,665 GWs CMC 0,10 % 280 V až 400 V; 5 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 400 V až 600 V; 0,1 A až 0,3 A 0,66 Ws až 4,665 GWs CMC 0,15 % 400 V až 600 V; 0,3 A až 0,5 A 0,66 Ws až 4,665 GWs CMC 0,11 % 400 V až 600 V; 0,5 A až 10 A 0,66 Ws až 4,665 GWs CMC 0,10 % 400 V až 600 V; 10 A až 90 A 0,66 Ws až 4,665 GWs CMC 0,12 % 600 V až 1000 V; 0,1 A až 0,33 A 0,66 Ws až 4,665 GWs CMC 0,18 % 600 V až 1000 V; 0,33 A až 0,9 A 0,66 Ws až 4,665 GWs CMC 0,28 % 600 V až 1000 V; 0,9 A až 2,2 A 0,66 Ws až 4,665 GWs CMC 0,18 % 600 V až 1000 V; 2,2 A až 4,5 A 0,66 Ws až 4,665 GWs CMC 0,23 % 600 V až 1000 V; 4,5 A až 11 A 0,66 Ws až 4,665 GWs CMC 0,18 % TP16 Energia elektryczna pradu przemiennego jedno- i trojfazowa / Liczniki energii elektrycznej pradu przemiennego jedno- i trojfazowe (f: 45 Hz do 65 Hz, PF = 1, t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 330 mV do 1 V; 3,3 mA do 9 mA od 0,66 Ws do 4,665 GWs CMC 0,28 % 330 mV do 1 V; 9 mA do 33 mA od 0,66 Ws do 4,665 GWs CMC 0,18 % 330 mV do 1 V; 33 mA do 90 mA od 0,66 Ws do 4,665 GWs CMC 0,28 % 330 mV do 1 V; 90 mA do 100 mA od 0,66 Ws do 4,665 GWs CMC 0,18 % 1 V do 5 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,20 % 1 V do 5 V; 0,3 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,18 % 5 V do 10 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 5 V do 10 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 5 V do 10 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 5 V do 10 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 10 V do 30 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 % 10 V do 30 V; 0,3 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 10 V do 30 V; 10 A do 30 A od 0,66 Ws do 4,665 GWs CMC 0,13 % 30 V do 50 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 % 30 V do 50 V; 0,3 A do 0,9 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 30 V do 50 V; 0,9 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 30 V do 50 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 50 V do 70 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 50 V do 70 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 50 V do 70 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 50 V do 70 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 50 V do 70 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 70 V do 100 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 70 V do 100 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 70 V do 100 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 70 V do 100 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 100 V do 140 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 100 V do 140 V; 0,3 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 100 V do 140 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 100 V do 140 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 140 V do 200 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,19 % 140 V do 200 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 140 V do 200 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 140 V do 200 V; 1 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 200 V do 280 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 200 V do 280 V; 0,3 A do 0,7 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 200 V do 280 V; 0,7 A do 1 A od 0,66 Ws do 4,665 GWs CMC 0,09 % 200 V do 280 V; 1 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 200 V do 280 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 280 V do 400 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,16 % 280 V do 400 V; 0,3 A do 0,5 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 280 V do 400 V; 0,5 A do 5 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 280 V do 400 V; 5 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 400 V do 600 V; 0,1 A do 0,3 A od 0,66 Ws do 4,665 GWs CMC 0,15 % 400 V do 600 V; 0,3 A do 0,5 A od 0,66 Ws do 4,665 GWs CMC 0,11 % 400 V do 600 V; 0,5 A do 10 A od 0,66 Ws do 4,665 GWs CMC 0,10 % 400 V do 600 V; 10 A do 90 A od 0,66 Ws do 4,665 GWs CMC 0,12 % 600 V do 1000 V; 0,1 A do 0,33 A od 0,66 Ws do 4,665 GWs CMC 0,18 % 600 V do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 4,665 GWs CMC 0,28 % 600 V do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 4,665 GWs CMC 0,18 % 600 V do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 4,665 GWs CMC 0,23 % 600 V do 1000 V; 4,5 A do 11 A od 0,66 Ws do 4,665 GWs CMC 0,18 % Stridava elektricka prace jednofazova i trifazova / Stridava meridla elektricke prace jednofazova i trifazova (f: 45 Hz az 65 Hz, PF = 1, t: 600 s az 24 h) Kalibrace – elektricke veliciny Prime generovani kalibratorem 330 mV az 1 V; 3,3 mA az 9 mA 0,66 Ws az 4,665 GWs CMC 0,28 % 330 mV az 1 V; 9 mA az 33 mA 0,66 Ws az 4,665 GWs CMC 0,18 % 330 mV az 1 V; 33 mA az 90 mA 0,66 Ws az 4,665 GWs CMC 0,28 % 330 mV az 1 V; 90 mA az 100 mA 0,66 Ws az 4,665 GWs CMC 0,18 % 1 V az 5 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,20 % 1 V az 5 V; 0,3 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,18 % 5 V az 10 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,15 % 5 V az 10 V; 0,3 A az 0,7 A 0,66 Ws az 4,665 GWs CMC 0,11 % 5 V az 10 V; 0,7 A az 1 A 0,66 Ws az 4,665 GWs CMC 0,09 % 5 V az 10 V; 1 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 10 V az 30 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,16 % 10 V az 30 V; 0,3 A az 10 A 0,66 Ws az 4,665 GWs CMC 0,11 % 10 V az 30 V; 10 A az 30 A 0,66 Ws az 4,665 GWs CMC 0,13 % 30 V az 50 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,16 % 30 V az 50 V; 0,3 A az 0,9 A 0,66 Ws az 4,665 GWs CMC 0,11 % 30 V az 50 V; 0,9 A az 1 A 0,66 Ws az 4,665 GWs CMC 0,09 % 30 V az 50 V; 1 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 50 V az 70 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,15 % 50 V az 70 V; 0,3 A az 0,7 A 0,66 Ws az 4,665 GWs CMC 0,10 % 50 V az 70 V; 0,7 A az 1 A 0,66 Ws az 4,665 GWs CMC 0,09 % 50 V az 70 V; 1 A az 10 A 0,66 Ws az 4,665 GWs CMC 0,10 % 50 V az 70 V; 10 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 70 V az 100 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,15 % 70 V az 100 V; 0,3 A az 0,7 A 0,66 Ws az 4,665 GWs CMC 0,11 % 70 V az 100 V; 0,7 A az 1 A 0,66 Ws az 4,665 GWs CMC 0,09 % 70 V az 100 V; 1 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 100 V az 140 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,15 % 100 V az 140 V; 0,3 A az 1 A 0,66 Ws az 4,665 GWs CMC 0,09 % 100 V az 140 V; 1 A az 10 A 0,66 Ws az 4,665 GWs CMC 0,10 % 100 V az 140 V; 10 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 140 V az 200 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,19 % 140 V az 200 V; 0,3 A az 0,7 A 0,66 Ws az 4,665 GWs CMC 0,11 % 140 V az 200 V; 0,7 A az 1 A 0,66 Ws az 4,665 GWs CMC 0,09 % 140 V az 200 V; 1 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 200 V az 280 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,15 % 200 V az 280 V; 0,3 A az 0,7 A 0,66 Ws az 4,665 GWs CMC 0,10 % 200 V az 280 V; 0,7 A az 1 A 0,66 Ws az 4,665 GWs CMC 0,09 % 200 V az 280 V; 1 A az 10 A 0,66 Ws az 4,665 GWs CMC 0,10 % 200 V az 280 V; 10 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 280 V az 400 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,16 % 280 V az 400 V; 0,3 A az 0,5 A 0,66 Ws az 4,665 GWs CMC 0,11 % 280 V az 400 V; 0,5 A az 5 A 0,66 Ws az 4,665 GWs CMC 0,10 % 280 V az 400 V; 5 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 400 V az 600 V; 0,1 A az 0,3 A 0,66 Ws az 4,665 GWs CMC 0,15 % 400 V az 600 V; 0,3 A az 0,5 A 0,66 Ws az 4,665 GWs CMC 0,11 % 400 V az 600 V; 0,5 A az 10 A 0,66 Ws az 4,665 GWs CMC 0,10 % 400 V az 600 V; 10 A az 90 A 0,66 Ws az 4,665 GWs CMC 0,12 % 600 V az 1000 V; 0,1 A az 0,33 A 0,66 Ws az 4,665 GWs CMC 0,18 % 600 V az 1000 V; 0,33 A az 0,9 A 0,66 Ws az 4,665 GWs CMC 0,28 % 600 V az 1000 V; 0,9 A az 2,2 A 0,66 Ws az 4,665 GWs CMC 0,18 % 600 V az 1000 V; 2,2 A az 4,5 A 0,66 Ws az 4,665 GWs CMC 0,23 % 600 V az 1000 V; 4,5 A az 11 A 0,66 Ws az 4,665 GWs CMC 0,18 % TP16","search_en":"AC electrical work, single- and three-phase / AC electrical work meters, single- and three-phase (f: 45 Hz to 65 Hz, PF = 1, t: 600 s to 24 h) Calibration – electrical quantities Direct generation with a calibrator 330 mV to 1 V; 3,3 mA to 9 mA 0,66 Ws to 4,665 GWs CMC 0,28 % 330 mV to 1 V; 9 mA to 33 mA 0,66 Ws to 4,665 GWs CMC 0,18 % 330 mV to 1 V; 33 mA to 90 mA 0,66 Ws to 4,665 GWs CMC 0,28 % 330 mV to 1 V; 90 mA to 100 mA 0,66 Ws to 4,665 GWs CMC 0,18 % 1 V to 5 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,20 % 1 V to 5 V; 0,3 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,18 % 5 V to 10 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,15 % 5 V to 10 V; 0,3 A to 0,7 A 0,66 Ws to 4,665 GWs CMC 0,11 % 5 V to 10 V; 0,7 A to 1 A 0,66 Ws to 4,665 GWs CMC 0,09 % 5 V to 10 V; 1 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 10 V to 30 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,16 % 10 V to 30 V; 0,3 A to 10 A 0,66 Ws to 4,665 GWs CMC 0,11 % 10 V to 30 V; 10 A to 30 A 0,66 Ws to 4,665 GWs CMC 0,13 % 30 V to 50 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,16 % 30 V to 50 V; 0,3 A to 0,9 A 0,66 Ws to 4,665 GWs CMC 0,11 % 30 V to 50 V; 0,9 A to 1 A 0,66 Ws to 4,665 GWs CMC 0,09 % 30 V to 50 V; 1 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 50 V to 70 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,15 % 50 V to 70 V; 0,3 A to 0,7 A 0,66 Ws to 4,665 GWs CMC 0,10 % 50 V to 70 V; 0,7 A to 1 A 0,66 Ws to 4,665 GWs CMC 0,09 % 50 V to 70 V; 1 A to 10 A 0,66 Ws to 4,665 GWs CMC 0,10 % 50 V to 70 V; 10 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 70 V to 100 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,15 % 70 V to 100 V; 0,3 A to 0,7 A 0,66 Ws to 4,665 GWs CMC 0,11 % 70 V to 100 V; 0,7 A to 1 A 0,66 Ws to 4,665 GWs CMC 0,09 % 70 V to 100 V; 1 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 100 V to 140 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,15 % 100 V to 140 V; 0,3 A to 1 A 0,66 Ws to 4,665 GWs CMC 0,09 % 100 V to 140 V; 1 A to 10 A 0,66 Ws to 4,665 GWs CMC 0,10 % 100 V to 140 V; 10 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 140 V to 200 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,19 % 140 V to 200 V; 0,3 A to 0,7 A 0,66 Ws to 4,665 GWs CMC 0,11 % 140 V to 200 V; 0,7 A to 1 A 0,66 Ws to 4,665 GWs CMC 0,09 % 140 V to 200 V; 1 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 200 V to 280 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,15 % 200 V to 280 V; 0,3 A to 0,7 A 0,66 Ws to 4,665 GWs CMC 0,10 % 200 V to 280 V; 0,7 A to 1 A 0,66 Ws to 4,665 GWs CMC 0,09 % 200 V to 280 V; 1 A to 10 A 0,66 Ws to 4,665 GWs CMC 0,10 % 200 V to 280 V; 10 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 280 V to 400 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,16 % 280 V to 400 V; 0,3 A to 0,5 A 0,66 Ws to 4,665 GWs CMC 0,11 % 280 V to 400 V; 0,5 A to 5 A 0,66 Ws to 4,665 GWs CMC 0,10 % 280 V to 400 V; 5 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 400 V to 600 V; 0,1 A to 0,3 A 0,66 Ws to 4,665 GWs CMC 0,15 % 400 V to 600 V; 0,3 A to 0,5 A 0,66 Ws to 4,665 GWs CMC 0,11 % 400 V to 600 V; 0,5 A to 10 A 0,66 Ws to 4,665 GWs CMC 0,10 % 400 V to 600 V; 10 A to 90 A 0,66 Ws to 4,665 GWs CMC 0,12 % 600 V to 1000 V; 0,1 A to 0,33 A 0,66 Ws to 4,665 GWs CMC 0,18 % 600 V to 1000 V; 0,33 A to 0,9 A 0,66 Ws to 4,665 GWs CMC 0,28 % 600 V to 1000 V; 0,9 A to 2,2 A 0,66 Ws to 4,665 GWs CMC 0,18 % 600 V to 1000 V; 2,2 A to 4,5 A 0,66 Ws to 4,665 GWs CMC 0,23 % 600 V to 1000 V; 4,5 A to 11 A 0,66 Ws to 4,665 GWs CMC 0,18 % TP16","search_zh":"单相和三相交流电能 / 单相和三相交流电能表（f：45 Hz 至 65 Hz，PF = 1，t：600 s 至 24 h） 校准 – 电学量 用校准器直接产生 330 mV 至 1 V；3,3 mA 至 9 mA 0,66 Ws 至 4,665 GWs CMC 0,28 % 330 mV 至 1 V；9 mA 至 33 mA 0,66 Ws 至 4,665 GWs CMC 0,18 % 330 mV 至 1 V；33 mA 至 90 mA 0,66 Ws 至 4,665 GWs CMC 0,28 % 330 mV 至 1 V；90 mA 至 100 mA 0,66 Ws 至 4,665 GWs CMC 0,18 % 1 V 至 5 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,20 % 1 V 至 5 V；0,3 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,18 % 5 V 至 10 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,15 % 5 V 至 10 V；0,3 A 至 0,7 A 0,66 Ws 至 4,665 GWs CMC 0,11 % 5 V 至 10 V；0,7 A 至 1 A 0,66 Ws 至 4,665 GWs CMC 0,09 % 5 V 至 10 V；1 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 10 V 至 30 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,16 % 10 V 至 30 V；0,3 A 至 10 A 0,66 Ws 至 4,665 GWs CMC 0,11 % 10 V 至 30 V；10 A 至 30 A 0,66 Ws 至 4,665 GWs CMC 0,13 % 30 V 至 50 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,16 % 30 V 至 50 V；0,3 A 至 0,9 A 0,66 Ws 至 4,665 GWs CMC 0,11 % 30 V 至 50 V；0,9 A 至 1 A 0,66 Ws 至 4,665 GWs CMC 0,09 % 30 V 至 50 V；1 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 50 V 至 70 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,15 % 50 V 至 70 V；0,3 A 至 0,7 A 0,66 Ws 至 4,665 GWs CMC 0,10 % 50 V 至 70 V；0,7 A 至 1 A 0,66 Ws 至 4,665 GWs CMC 0,09 % 50 V 至 70 V；1 A 至 10 A 0,66 Ws 至 4,665 GWs CMC 0,10 % 50 V 至 70 V；10 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 70 V 至 100 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,15 % 70 V 至 100 V；0,3 A 至 0,7 A 0,66 Ws 至 4,665 GWs CMC 0,11 % 70 V 至 100 V；0,7 A 至 1 A 0,66 Ws 至 4,665 GWs CMC 0,09 % 70 V 至 100 V；1 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 100 V 至 140 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,15 % 100 V 至 140 V；0,3 A 至 1 A 0,66 Ws 至 4,665 GWs CMC 0,09 % 100 V 至 140 V；1 A 至 10 A 0,66 Ws 至 4,665 GWs CMC 0,10 % 100 V 至 140 V；10 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 140 V 至 200 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,19 % 140 V 至 200 V；0,3 A 至 0,7 A 0,66 Ws 至 4,665 GWs CMC 0,11 % 140 V 至 200 V；0,7 A 至 1 A 0,66 Ws 至 4,665 GWs CMC 0,09 % 140 V 至 200 V；1 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 200 V 至 280 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,15 % 200 V 至 280 V；0,3 A 至 0,7 A 0,66 Ws 至 4,665 GWs CMC 0,10 % 200 V 至 280 V；0,7 A 至 1 A 0,66 Ws 至 4,665 GWs CMC 0,09 % 200 V 至 280 V；1 A 至 10 A 0,66 Ws 至 4,665 GWs CMC 0,10 % 200 V 至 280 V；10 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 280 V 至 400 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,16 % 280 V 至 400 V；0,3 A 至 0,5 A 0,66 Ws 至 4,665 GWs CMC 0,11 % 280 V 至 400 V；0,5 A 至 5 A 0,66 Ws 至 4,665 GWs CMC 0,10 % 280 V 至 400 V；5 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 400 V 至 600 V；0,1 A 至 0,3 A 0,66 Ws 至 4,665 GWs CMC 0,15 % 400 V 至 600 V；0,3 A 至 0,5 A 0,66 Ws 至 4,665 GWs CMC 0,11 % 400 V 至 600 V；0,5 A 至 10 A 0,66 Ws 至 4,665 GWs CMC 0,10 % 400 V 至 600 V；10 A 至 90 A 0,66 Ws 至 4,665 GWs CMC 0,12 % 600 V 至 1000 V；0,1 A 至 0,33 A 0,66 Ws 至 4,665 GWs CMC 0,18 % 600 V 至 1000 V；0,33 A 至 0,9 A 0,66 Ws 至 4,665 GWs CMC 0,28 % 600 V 至 1000 V；0,9 A 至 2,2 A 0,66 Ws 至 4,665 GWs CMC 0,18 % 600 V 至 1000 V；2,2 A 至 4,5 A 0,66 Ws 至 4,665 GWs CMC 0,23 % 600 V 至 1000 V；4,5 A 至 11 A 0,66 Ws 至 4,665 GWs CMC 0,18 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4dd6fe22cc54e19f00fbfabb","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"22","test_object":"Energia elektryczna prądu przemiennego jedno- i trójfazowa / Liczniki energii elektrycznej prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 0,5 indukcyjny i pojemnościowy, t: 600 s do 24 h)","test_object_en":"AC electrical work, single- and three-phase / AC electrical work meters, single- and three-phase (f: 45 Hz to 65 Hz, PF = 0,5 inductive and capacitive, t: 600 s to 24 h)","test_object_zh":"单相和三相交流电能 / 单相和三相交流电能表（f：45 Hz 至 65 Hz，PF = 0,5 感性和容性，t：600 s 至 24 h）","test_object_cs":"Střídavá elektrická práce jednofázová i třífázová / Střídavá měřidla elektrické práce jednofázová i třífázová (f: 45 Hz až 65 Hz, PF = 0,5 induktivní a kapacitní t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"330 mV do 5 V; 3,3 mA do 9 mA","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV do 5 V; 9 mA do 33 mA","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,53 %"},{"name":"330 mV do 5 V; 33 mA do 90 mA","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV do 5 V; 90 mA do 100 mA","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,53 %"},{"name":"5 V do 600 V; 0,1 A do 0,3 A","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,20 %"},{"name":"5 V do 600 V; 0,3 A do 10 A","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,17 %"},{"name":"5 V do 600 V; 10 A do 90 A","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,25 %"},{"name":"5 V do 600 V; 0,1 A do 0,3 A","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,16 %"},{"name":"5 V do 600 V; 0,3 A do 10 A","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,12 %"},{"name":"5 V do 600 V; 10 A do 90 A","range":"od 0,33 Ws do 2,332 GWs","cmc":"0,22 %"}],"parameters_en":[{"name":"330 mV to 5 V; 3,3 mA to 9 mA","range":"0,33 Ws to 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV to 5 V; 9 mA to 33 mA","range":"0,33 Ws to 2,332 GWs","cmc":"0,53 %"},{"name":"330 mV to 5 V; 33 mA to 90 mA","range":"0,33 Ws to 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV to 5 V; 90 mA to 100 mA","range":"0,33 Ws to 2,332 GWs","cmc":"0,53 %"},{"name":"5 V to 600 V; 0,1 A to 0,3 A","range":"0,33 Ws to 2,332 GWs","cmc":"0,20 %"},{"name":"5 V to 600 V; 0,3 A to 10 A","range":"0,33 Ws to 2,332 GWs","cmc":"0,17 %"},{"name":"5 V to 600 V; 10 A to 90 A","range":"0,33 Ws to 2,332 GWs","cmc":"0,25 %"},{"name":"5 V to 600 V; 0,1 A to 0,3 A","range":"0,33 Ws to 2,332 GWs","cmc":"0,16 %"},{"name":"5 V to 600 V; 0,3 A to 10 A","range":"0,33 Ws to 2,332 GWs","cmc":"0,12 %"},{"name":"5 V to 600 V; 10 A to 90 A","range":"0,33 Ws to 2,332 GWs","cmc":"0,22 %"}],"parameters_zh":[{"name":"330 mV 至 5 V；3,3 mA 至 9 mA","range":"0,33 Ws 至 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV 至 5 V；9 mA 至 33 mA","range":"0,33 Ws 至 2,332 GWs","cmc":"0,53 %"},{"name":"330 mV 至 5 V；33 mA 至 90 mA","range":"0,33 Ws 至 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV 至 5 V；90 mA 至 100 mA","range":"0,33 Ws 至 2,332 GWs","cmc":"0,53 %"},{"name":"5 V 至 600 V；0,1 A 至 0,3 A","range":"0,33 Ws 至 2,332 GWs","cmc":"0,20 %"},{"name":"5 V 至 600 V；0,3 A 至 10 A","range":"0,33 Ws 至 2,332 GWs","cmc":"0,17 %"},{"name":"5 V 至 600 V；10 A 至 90 A","range":"0,33 Ws 至 2,332 GWs","cmc":"0,25 %"},{"name":"5 V 至 600 V；0,1 A 至 0,3 A","range":"0,33 Ws 至 2,332 GWs","cmc":"0,16 %"},{"name":"5 V 至 600 V；0,3 A 至 10 A","range":"0,33 Ws 至 2,332 GWs","cmc":"0,12 %"},{"name":"5 V 至 600 V；10 A 至 90 A","range":"0,33 Ws 至 2,332 GWs","cmc":"0,22 %"}],"parameters_cs":[{"name":"330 mV až 5 V; 3,3 mA až 9 mA","range":"0,33 Ws až 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV až 5 V; 9 mA až 33 mA","range":"0,33 Ws až 2,332 GWs","cmc":"0,53 %"},{"name":"330 mV až 5 V; 33 mA až 90 mA","range":"0,33 Ws až 2,332 GWs","cmc":"0,58 %"},{"name":"330 mV až 5 V; 90 mA až 100 mA","range":"0,33 Ws až 2,332 GWs","cmc":"0,53 %"},{"name":"5 V až 600 V; 0,1 A až 0,3 A","range":"0,33 Ws až 2,332 GWs","cmc":"0,20 %"},{"name":"5 V až 600 V; 0,3 A až 10 A","range":"0,33 Ws až 2,332 GWs","cmc":"0,17 %"},{"name":"5 V až 600 V; 10 A až 90 A","range":"0,33 Ws až 2,332 GWs","cmc":"0,25 %"},{"name":"5 V až 600 V; 0,1 A až 0,3 A","range":"0,33 Ws až 2,332 GWs","cmc":"0,16 %"},{"name":"5 V až 600 V; 0,3 A až 10 A","range":"0,33 Ws až 2,332 GWs","cmc":"0,12 %"},{"name":"5 V až 600 V; 10 A až 90 A","range":"0,33 Ws až 2,332 GWs","cmc":"0,22 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n330 mV do 5 V; 3,3 mA do 9 mA od 0,33 Ws do 2,332 GWs CMC 0,58 %\n330 mV do 5 V; 9 mA do 33 mA od 0,33 Ws do 2,332 GWs CMC 0,53 %\n330 mV do 5 V; 33 mA do 90 mA od 0,33 Ws do 2,332 GWs CMC 0,58 %\n330 mV do 5 V; 90 mA do 100 mA od 0,33 Ws do 2,332 GWs CMC 0,53 %\n5 V do 600 V; 0,1 A do 0,3 A od 0,33 Ws do 2,332 GWs CMC 0,20 %\n5 V do 600 V; 0,3 A do 10 A od 0,33 Ws do 2,332 GWs CMC 0,17 %\n5 V do 600 V; 10 A do 90 A od 0,33 Ws do 2,332 GWs CMC 0,25 %\n5 V do 600 V; 0,1 A do 0,3 A od 0,33 Ws do 2,332 GWs CMC 0,16 %\n5 V do 600 V; 0,3 A do 10 A od 0,33 Ws do 2,332 GWs CMC 0,12 %\n5 V do 600 V; 10 A do 90 A od 0,33 Ws do 2,332 GWs CMC 0,22 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu przemiennego jedno- i trójfazowa / Liczniki energii elektrycznej prądu przemiennego jedno- i trójfazowe (f: 45 Hz do 65 Hz, PF = 0,5 indukcyjny i pojemnościowy, t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 330 mV do 5 V; 3,3 mA do 9 mA od 0,33 Ws do 2,332 GWs CMC 0,58 % 330 mV do 5 V; 9 mA do 33 mA od 0,33 Ws do 2,332 GWs CMC 0,53 % 330 mV do 5 V; 33 mA do 90 mA od 0,33 Ws do 2,332 GWs CMC 0,58 % 330 mV do 5 V; 90 mA do 100 mA od 0,33 Ws do 2,332 GWs CMC 0,53 % 5 V do 600 V; 0,1 A do 0,3 A od 0,33 Ws do 2,332 GWs CMC 0,20 % 5 V do 600 V; 0,3 A do 10 A od 0,33 Ws do 2,332 GWs CMC 0,17 % 5 V do 600 V; 10 A do 90 A od 0,33 Ws do 2,332 GWs CMC 0,25 % 5 V do 600 V; 0,1 A do 0,3 A od 0,33 Ws do 2,332 GWs CMC 0,16 % 5 V do 600 V; 0,3 A do 10 A od 0,33 Ws do 2,332 GWs CMC 0,12 % 5 V do 600 V; 10 A do 90 A od 0,33 Ws do 2,332 GWs CMC 0,22 % Střídavá elektrická práce jednofázová i třífázová / Střídavá měřidla elektrické práce jednofázová i třífázová (f: 45 Hz až 65 Hz, PF = 0,5 induktivní a kapacitní t: 600 s až 24 h) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 330 mV až 5 V; 3,3 mA až 9 mA 0,33 Ws až 2,332 GWs CMC 0,58 % 330 mV až 5 V; 9 mA až 33 mA 0,33 Ws až 2,332 GWs CMC 0,53 % 330 mV až 5 V; 33 mA až 90 mA 0,33 Ws až 2,332 GWs CMC 0,58 % 330 mV až 5 V; 90 mA až 100 mA 0,33 Ws až 2,332 GWs CMC 0,53 % 5 V až 600 V; 0,1 A až 0,3 A 0,33 Ws až 2,332 GWs CMC 0,20 % 5 V až 600 V; 0,3 A až 10 A 0,33 Ws až 2,332 GWs CMC 0,17 % 5 V až 600 V; 10 A až 90 A 0,33 Ws až 2,332 GWs CMC 0,25 % 5 V až 600 V; 0,1 A až 0,3 A 0,33 Ws až 2,332 GWs CMC 0,16 % 5 V až 600 V; 0,3 A až 10 A 0,33 Ws až 2,332 GWs CMC 0,12 % 5 V až 600 V; 10 A až 90 A 0,33 Ws až 2,332 GWs CMC 0,22 % TP16 Energia elektryczna pradu przemiennego jedno- i trojfazowa / Liczniki energii elektrycznej pradu przemiennego jedno- i trojfazowe (f: 45 Hz do 65 Hz, PF = 0,5 indukcyjny i pojemnosciowy, t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 330 mV do 5 V; 3,3 mA do 9 mA od 0,33 Ws do 2,332 GWs CMC 0,58 % 330 mV do 5 V; 9 mA do 33 mA od 0,33 Ws do 2,332 GWs CMC 0,53 % 330 mV do 5 V; 33 mA do 90 mA od 0,33 Ws do 2,332 GWs CMC 0,58 % 330 mV do 5 V; 90 mA do 100 mA od 0,33 Ws do 2,332 GWs CMC 0,53 % 5 V do 600 V; 0,1 A do 0,3 A od 0,33 Ws do 2,332 GWs CMC 0,20 % 5 V do 600 V; 0,3 A do 10 A od 0,33 Ws do 2,332 GWs CMC 0,17 % 5 V do 600 V; 10 A do 90 A od 0,33 Ws do 2,332 GWs CMC 0,25 % 5 V do 600 V; 0,1 A do 0,3 A od 0,33 Ws do 2,332 GWs CMC 0,16 % 5 V do 600 V; 0,3 A do 10 A od 0,33 Ws do 2,332 GWs CMC 0,12 % 5 V do 600 V; 10 A do 90 A od 0,33 Ws do 2,332 GWs CMC 0,22 % Stridava elektricka prace jednofazova i trifazova / Stridava meridla elektricke prace jednofazova i trifazova (f: 45 Hz az 65 Hz, PF = 0,5 induktivni a kapacitni t: 600 s az 24 h) Kalibrace – elektricke veliciny Prime generovani kalibratorem 330 mV az 5 V; 3,3 mA az 9 mA 0,33 Ws az 2,332 GWs CMC 0,58 % 330 mV az 5 V; 9 mA az 33 mA 0,33 Ws az 2,332 GWs CMC 0,53 % 330 mV az 5 V; 33 mA az 90 mA 0,33 Ws az 2,332 GWs CMC 0,58 % 330 mV az 5 V; 90 mA az 100 mA 0,33 Ws az 2,332 GWs CMC 0,53 % 5 V az 600 V; 0,1 A az 0,3 A 0,33 Ws az 2,332 GWs CMC 0,20 % 5 V az 600 V; 0,3 A az 10 A 0,33 Ws az 2,332 GWs CMC 0,17 % 5 V az 600 V; 10 A az 90 A 0,33 Ws az 2,332 GWs CMC 0,25 % 5 V az 600 V; 0,1 A az 0,3 A 0,33 Ws az 2,332 GWs CMC 0,16 % 5 V az 600 V; 0,3 A az 10 A 0,33 Ws az 2,332 GWs CMC 0,12 % 5 V az 600 V; 10 A az 90 A 0,33 Ws az 2,332 GWs CMC 0,22 % TP16","search_en":"AC electrical work, single- and three-phase / AC electrical work meters, single- and three-phase (f: 45 Hz to 65 Hz, PF = 0,5 inductive and capacitive, t: 600 s to 24 h) Calibration – electrical quantities Direct generation with a calibrator 330 mV to 5 V; 3,3 mA to 9 mA 0,33 Ws to 2,332 GWs CMC 0,58 % 330 mV to 5 V; 9 mA to 33 mA 0,33 Ws to 2,332 GWs CMC 0,53 % 330 mV to 5 V; 33 mA to 90 mA 0,33 Ws to 2,332 GWs CMC 0,58 % 330 mV to 5 V; 90 mA to 100 mA 0,33 Ws to 2,332 GWs CMC 0,53 % 5 V to 600 V; 0,1 A to 0,3 A 0,33 Ws to 2,332 GWs CMC 0,20 % 5 V to 600 V; 0,3 A to 10 A 0,33 Ws to 2,332 GWs CMC 0,17 % 5 V to 600 V; 10 A to 90 A 0,33 Ws to 2,332 GWs CMC 0,25 % 5 V to 600 V; 0,1 A to 0,3 A 0,33 Ws to 2,332 GWs CMC 0,16 % 5 V to 600 V; 0,3 A to 10 A 0,33 Ws to 2,332 GWs CMC 0,12 % 5 V to 600 V; 10 A to 90 A 0,33 Ws to 2,332 GWs CMC 0,22 % TP16","search_zh":"单相和三相交流电能 / 单相和三相交流电能表（f：45 Hz 至 65 Hz，PF = 0,5 感性和容性，t：600 s 至 24 h） 校准 – 电学量 用校准器直接产生 330 mV 至 5 V；3,3 mA 至 9 mA 0,33 Ws 至 2,332 GWs CMC 0,58 % 330 mV 至 5 V；9 mA 至 33 mA 0,33 Ws 至 2,332 GWs CMC 0,53 % 330 mV 至 5 V；33 mA 至 90 mA 0,33 Ws 至 2,332 GWs CMC 0,58 % 330 mV 至 5 V；90 mA 至 100 mA 0,33 Ws 至 2,332 GWs CMC 0,53 % 5 V 至 600 V；0,1 A 至 0,3 A 0,33 Ws 至 2,332 GWs CMC 0,20 % 5 V 至 600 V；0,3 A 至 10 A 0,33 Ws 至 2,332 GWs CMC 0,17 % 5 V 至 600 V；10 A 至 90 A 0,33 Ws 至 2,332 GWs CMC 0,25 % 5 V 至 600 V；0,1 A 至 0,3 A 0,33 Ws 至 2,332 GWs CMC 0,16 % 5 V 至 600 V；0,3 A 至 10 A 0,33 Ws 至 2,332 GWs CMC 0,12 % 5 V 至 600 V；10 A 至 90 A 0,33 Ws 至 2,332 GWs CMC 0,22 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b5cd75ea5441140b9daae210","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"22","test_object":"Energia elektryczna prądu przemiennego jednofazowa / Liczniki energii elektrycznej prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 1, t: 600 s do 24 h)","test_object_en":"AC electrical work, single-phase / AC electrical work meters, single-phase (f: 65 Hz to 500 Hz, PF = 1, t: 600 s to 24 h)","test_object_zh":"单相交流电能 / 单相交流电能表（f：65 Hz 至 500 Hz，PF = 1，t：600 s 至 24 h）","test_object_cs":"Střídavá elektrická práce jednofázová / Střídavá měřidla elektrické práce jednofázová (f: 65 Hz až 500 Hz, PF = 1, t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"330 mV do 1000 V; 3,3 mA do 9 mA","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV do 1000 V; 9 mA do 33 mA","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV do 1000 V; 33 mA do 90 mA","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV do 1000 V; 90 mA do 100 mA","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV do 1000 V; 0,33 A do 0,9 A","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV do 1000 V; 0,9 A do 2,2 A","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV do 1000 V; 2,2 A do 4,5 A","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,24 %"},{"name":"330 mV do 1000 V; 4,5 A do 11 A","range":"od 0,66 Ws do 950,4 MWs","cmc":"0,19 %"}],"parameters_en":[{"name":"330 mV to 1000 V; 3,3 mA to 9 mA","range":"0,66 Ws to 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV to 1000 V; 9 mA to 33 mA","range":"0,66 Ws to 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV to 1000 V; 33 mA to 90 mA","range":"0,66 Ws to 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV to 1000 V; 90 mA to 100 mA","range":"0,66 Ws to 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV to 1000 V; 0,33 A to 0,9 A","range":"0,66 Ws to 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV to 1000 V; 0,9 A to 2,2 A","range":"0,66 Ws to 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV to 1000 V; 2,2 A to 4,5 A","range":"0,66 Ws to 950,4 MWs","cmc":"0,24 %"},{"name":"330 mV to 1000 V; 4,5 A to 11 A","range":"0,66 Ws to 950,4 MWs","cmc":"0,19 %"}],"parameters_zh":[{"name":"330 mV 至 1000 V；3,3 mA 至 9 mA","range":"0,66 Ws 至 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV 至 1000 V；9 mA 至 33 mA","range":"0,66 Ws 至 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV 至 1000 V；33 mA 至 90 mA","range":"0,66 Ws 至 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV 至 1000 V；90 mA 至 100 mA","range":"0,66 Ws 至 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV 至 1000 V；0,33 A 至 0,9 A","range":"0,66 Ws 至 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV 至 1000 V；0,9 A 至 2,2 A","range":"0,66 Ws 至 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV 至 1000 V；2,2 A 至 4,5 A","range":"0,66 Ws 至 950,4 MWs","cmc":"0,24 %"},{"name":"330 mV 至 1000 V；4,5 A 至 11 A","range":"0,66 Ws 至 950,4 MWs","cmc":"0,19 %"}],"parameters_cs":[{"name":"330 mV až 1000 V; 3,3 mA až 9 mA","range":"0,66 Ws až 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV až 1000 V; 9 mA až 33 mA","range":"0,66 Ws až 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV až 1000 V; 33 mA až 90 mA","range":"0,66 Ws až 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV až 1000 V; 90 mA až 100 mA","range":"0,66 Ws až 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV až 1000 V; 0,33 A až 0,9 A","range":"0,66 Ws až 950,4 MWs","cmc":"0,29 %"},{"name":"330 mV až 1000 V; 0,9 A až 2,2 A","range":"0,66 Ws až 950,4 MWs","cmc":"0,19 %"},{"name":"330 mV až 1000 V; 2,2 A až 4,5 A","range":"0,66 Ws až 950,4 MWs","cmc":"0,24 %"},{"name":"330 mV až 1000 V; 4,5 A až 11 A","range":"0,66 Ws až 950,4 MWs","cmc":"0,19 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n330 mV do 1000 V; 3,3 mA do 9 mA od 0,66 Ws do 950,4 MWs CMC 0,29 %\n330 mV do 1000 V; 9 mA do 33 mA od 0,66 Ws do 950,4 MWs CMC 0,19 %\n330 mV do 1000 V; 33 mA do 90 mA od 0,66 Ws do 950,4 MWs CMC 0,29 %\n330 mV do 1000 V; 90 mA do 100 mA od 0,66 Ws do 950,4 MWs CMC 0,19 %\n330 mV do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 950,4 MWs CMC 0,29 %\n330 mV do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 950,4 MWs CMC 0,19 %\n330 mV do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 950,4 MWs CMC 0,24 %\n330 mV do 1000 V; 4,5 A do 11 A od 0,66 Ws do 950,4 MWs CMC 0,19 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu przemiennego jednofazowa / Liczniki energii elektrycznej prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 1, t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 9 mA od 0,66 Ws do 950,4 MWs CMC 0,29 % 330 mV do 1000 V; 9 mA do 33 mA od 0,66 Ws do 950,4 MWs CMC 0,19 % 330 mV do 1000 V; 33 mA do 90 mA od 0,66 Ws do 950,4 MWs CMC 0,29 % 330 mV do 1000 V; 90 mA do 100 mA od 0,66 Ws do 950,4 MWs CMC 0,19 % 330 mV do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 950,4 MWs CMC 0,29 % 330 mV do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 950,4 MWs CMC 0,19 % 330 mV do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 950,4 MWs CMC 0,24 % 330 mV do 1000 V; 4,5 A do 11 A od 0,66 Ws do 950,4 MWs CMC 0,19 % Střídavá elektrická práce jednofázová / Střídavá měřidla elektrické práce jednofázová (f: 65 Hz až 500 Hz, PF = 1, t: 600 s až 24 h) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 330 mV až 1000 V; 3,3 mA až 9 mA 0,66 Ws až 950,4 MWs CMC 0,29 % 330 mV až 1000 V; 9 mA až 33 mA 0,66 Ws až 950,4 MWs CMC 0,19 % 330 mV až 1000 V; 33 mA až 90 mA 0,66 Ws až 950,4 MWs CMC 0,29 % 330 mV až 1000 V; 90 mA až 100 mA 0,66 Ws až 950,4 MWs CMC 0,19 % 330 mV až 1000 V; 0,33 A až 0,9 A 0,66 Ws až 950,4 MWs CMC 0,29 % 330 mV až 1000 V; 0,9 A až 2,2 A 0,66 Ws až 950,4 MWs CMC 0,19 % 330 mV až 1000 V; 2,2 A až 4,5 A 0,66 Ws až 950,4 MWs CMC 0,24 % 330 mV až 1000 V; 4,5 A až 11 A 0,66 Ws až 950,4 MWs CMC 0,19 % TP16 Energia elektryczna pradu przemiennego jednofazowa / Liczniki energii elektrycznej pradu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 1, t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 9 mA od 0,66 Ws do 950,4 MWs CMC 0,29 % 330 mV do 1000 V; 9 mA do 33 mA od 0,66 Ws do 950,4 MWs CMC 0,19 % 330 mV do 1000 V; 33 mA do 90 mA od 0,66 Ws do 950,4 MWs CMC 0,29 % 330 mV do 1000 V; 90 mA do 100 mA od 0,66 Ws do 950,4 MWs CMC 0,19 % 330 mV do 1000 V; 0,33 A do 0,9 A od 0,66 Ws do 950,4 MWs CMC 0,29 % 330 mV do 1000 V; 0,9 A do 2,2 A od 0,66 Ws do 950,4 MWs CMC 0,19 % 330 mV do 1000 V; 2,2 A do 4,5 A od 0,66 Ws do 950,4 MWs CMC 0,24 % 330 mV do 1000 V; 4,5 A do 11 A od 0,66 Ws do 950,4 MWs CMC 0,19 % Stridava elektricka prace jednofazova / Stridava meridla elektricke prace jednofazova (f: 65 Hz az 500 Hz, PF = 1, t: 600 s az 24 h) Kalibrace – elektricke veliciny Prime generovani kalibratorem 330 mV az 1000 V; 3,3 mA az 9 mA 0,66 Ws az 950,4 MWs CMC 0,29 % 330 mV az 1000 V; 9 mA az 33 mA 0,66 Ws az 950,4 MWs CMC 0,19 % 330 mV az 1000 V; 33 mA az 90 mA 0,66 Ws az 950,4 MWs CMC 0,29 % 330 mV az 1000 V; 90 mA az 100 mA 0,66 Ws az 950,4 MWs CMC 0,19 % 330 mV az 1000 V; 0,33 A az 0,9 A 0,66 Ws az 950,4 MWs CMC 0,29 % 330 mV az 1000 V; 0,9 A az 2,2 A 0,66 Ws az 950,4 MWs CMC 0,19 % 330 mV az 1000 V; 2,2 A az 4,5 A 0,66 Ws az 950,4 MWs CMC 0,24 % 330 mV az 1000 V; 4,5 A az 11 A 0,66 Ws az 950,4 MWs CMC 0,19 % TP16","search_en":"AC electrical work, single-phase / AC electrical work meters, single-phase (f: 65 Hz to 500 Hz, PF = 1, t: 600 s to 24 h) Calibration – electrical quantities Direct generation with a calibrator 330 mV to 1000 V; 3,3 mA to 9 mA 0,66 Ws to 950,4 MWs CMC 0,29 % 330 mV to 1000 V; 9 mA to 33 mA 0,66 Ws to 950,4 MWs CMC 0,19 % 330 mV to 1000 V; 33 mA to 90 mA 0,66 Ws to 950,4 MWs CMC 0,29 % 330 mV to 1000 V; 90 mA to 100 mA 0,66 Ws to 950,4 MWs CMC 0,19 % 330 mV to 1000 V; 0,33 A to 0,9 A 0,66 Ws to 950,4 MWs CMC 0,29 % 330 mV to 1000 V; 0,9 A to 2,2 A 0,66 Ws to 950,4 MWs CMC 0,19 % 330 mV to 1000 V; 2,2 A to 4,5 A 0,66 Ws to 950,4 MWs CMC 0,24 % 330 mV to 1000 V; 4,5 A to 11 A 0,66 Ws to 950,4 MWs CMC 0,19 % TP16","search_zh":"单相交流电能 / 单相交流电能表（f：65 Hz 至 500 Hz，PF = 1，t：600 s 至 24 h） 校准 – 电学量 用校准器直接产生 330 mV 至 1000 V；3,3 mA 至 9 mA 0,66 Ws 至 950,4 MWs CMC 0,29 % 330 mV 至 1000 V；9 mA 至 33 mA 0,66 Ws 至 950,4 MWs CMC 0,19 % 330 mV 至 1000 V；33 mA 至 90 mA 0,66 Ws 至 950,4 MWs CMC 0,29 % 330 mV 至 1000 V；90 mA 至 100 mA 0,66 Ws 至 950,4 MWs CMC 0,19 % 330 mV 至 1000 V；0,33 A 至 0,9 A 0,66 Ws 至 950,4 MWs CMC 0,29 % 330 mV 至 1000 V；0,9 A 至 2,2 A 0,66 Ws 至 950,4 MWs CMC 0,19 % 330 mV 至 1000 V；2,2 A 至 4,5 A 0,66 Ws 至 950,4 MWs CMC 0,24 % 330 mV 至 1000 V；4,5 A 至 11 A 0,66 Ws 至 950,4 MWs CMC 0,19 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"837f682c460897abc7bd6802","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"22","test_object":"Energia elektryczna prądu przemiennego jednofazowa / Liczniki energii elektrycznej prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 0,5 indukcyjny i pojemnościowy, t: 600 s do 24 h)","test_object_en":"AC electrical work, single-phase / AC electrical work meters, single-phase (f: 65 Hz to 500 Hz, PF = 0,5 inductive and capacitive, t: 600 s to 24 h)","test_object_zh":"单相交流电能 / 单相交流电能表（f：65 Hz 至 500 Hz，PF = 0,5 感性和容性，t：600 s 至 24 h）","test_object_cs":"Střídavá elektrická práce jednofázová / Střídavá měřidla elektrické práce jednofázová (f: 65 Hz až 500 Hz, PF = 0,5 induktivní a kapacitní t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"330 mV do 1000 V; 3,3 mA do 11 A","range":"od 0,33 Ws do 475,2 MWs","cmc":"2,9 %"}],"parameters_en":[{"name":"330 mV to 1000 V; 3,3 mA to 11 A","range":"0,33 Ws to 475,2 MWs","cmc":"2,9 %"}],"parameters_zh":[{"name":"330 mV 至 1000 V；3,3 mA 至 11 A","range":"0,33 Ws 至 475,2 MWs","cmc":"2,9 %"}],"parameters_cs":[{"name":"330 mV až 1000 V; 3,3 mA až 11 A","range":"0,33 Ws až 475,2 MWs","cmc":"2,9 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n330 mV do 1000 V; 3,3 mA do 11 A od 0,33 Ws do 475,2 MWs CMC 2,9 %\nBezpośrednie generowanie kalibratorem","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu przemiennego jednofazowa / Liczniki energii elektrycznej prądu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 0,5 indukcyjny i pojemnościowy, t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 11 A od 0,33 Ws do 475,2 MWs CMC 2,9 % Střídavá elektrická práce jednofázová / Střídavá měřidla elektrické práce jednofázová (f: 65 Hz až 500 Hz, PF = 0,5 induktivní a kapacitní t: 600 s až 24 h) Kalibrace – elektrické veličiny Přímé generování kalibrátorem 330 mV až 1000 V; 3,3 mA až 11 A 0,33 Ws až 475,2 MWs CMC 2,9 % TP16 Energia elektryczna pradu przemiennego jednofazowa / Liczniki energii elektrycznej pradu przemiennego jednofazowe (f: 65 Hz do 500 Hz, PF = 0,5 indukcyjny i pojemnosciowy, t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 330 mV do 1000 V; 3,3 mA do 11 A od 0,33 Ws do 475,2 MWs CMC 2,9 % Stridava elektricka prace jednofazova / Stridava meridla elektricke prace jednofazova (f: 65 Hz az 500 Hz, PF = 0,5 induktivni a kapacitni t: 600 s az 24 h) Kalibrace – elektricke veliciny Prime generovani kalibratorem 330 mV az 1000 V; 3,3 mA az 11 A 0,33 Ws az 475,2 MWs CMC 2,9 % TP16","search_en":"AC electrical work, single-phase / AC electrical work meters, single-phase (f: 65 Hz to 500 Hz, PF = 0,5 inductive and capacitive, t: 600 s to 24 h) Calibration – electrical quantities Direct generation with a calibrator 330 mV to 1000 V; 3,3 mA to 11 A 0,33 Ws to 475,2 MWs CMC 2,9 % TP16","search_zh":"单相交流电能 / 单相交流电能表（f：65 Hz 至 500 Hz，PF = 0,5 感性和容性，t：600 s 至 24 h） 校准 – 电学量 用校准器直接产生 330 mV 至 1000 V；3,3 mA 至 11 A 0,33 Ws 至 475,2 MWs CMC 2,9 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"378905e6a10b57054f7108cc","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"22","test_object":"Energia elektryczna prądu przemiennego jedno- i trójfazowa / Liczniki energii elektrycznej prądu przemiennego jedno- i trójfazowe z wejściami prądowymi (f: 45 Hz do 65 Hz, PF = 1, t: 600 s do 24 h)","test_object_en":"AC electrical work, single- and three-phase / AC electrical work meters, single-phase and three-phase with current inputs (f: 45 Hz to 65 Hz, PF = 1, t: 600 s to 24 h)","test_object_zh":"单相和三相交流电能 / 带电流输入的单相和三相交流电能表（f：45 Hz 至 65 Hz，PF = 1，t：600 s 至 24 h）","test_object_cs":"Střídavá elektrická práce jednofázová i třífázová / Střídavá měřidla elektrické práce jednofázová i třífázová s proudovými vstupy (f: 45 Hz až 65 Hz, PF = 1, t: 600 s až 24 h)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 V do 600 V; 10 A do 2250 A","range":"od 6 kWs do 116,6 GWs","cmc":"0,55 %"}],"parameters_en":[{"name":"1 V to 600 V; 10 A to 2250 A","range":"6 kWs to 116,6 GWs","cmc":"0,55 %"}],"parameters_zh":[{"name":"1 V 至 600 V；10 A 至 2250 A","range":"6 kWs 至 116,6 GWs","cmc":"0,55 %"}],"parameters_cs":[{"name":"1 V až 600 V; 10 A až 2250 A","range":"6 kWs až 116,6 GWs","cmc":"0,55 %"}],"technique":"Pośrednie generowanie kalibratorem z cewką prądową, cewkami prądowymi","technique_en":"Indirect generation with a calibrator with current coil, current coils","technique_zh":"用带电流线圈的校准器间接产生","technique_cs":"Nepřímé generování kalibrátorem s proudovou cívkou, proudovými cívkami","techniques":["Pośrednie generowanie kalibratorem z cewką prądową, cewkami prądowymi"],"techniques_en":["Indirect generation with a calibrator with current coil, current coils"],"techniques_zh":["用带电流线圈的校准器间接产生"],"techniques_cs":["Nepřímé generování kalibrátorem s proudovou cívkou, proudovými cívkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 V do 600 V; 10 A do 2250 A od 6 kWs do 116,6 GWs CMC 0,55 %\nPośrednie generowanie kalibratorem z cewką prądową, cewkami prądowymi","reference":"TP16","norm_bases":["TP16"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Energia elektryczna prądu przemiennego jedno- i trójfazowa / Liczniki energii elektrycznej prądu przemiennego jedno- i trójfazowe z wejściami prądowymi (f: 45 Hz do 65 Hz, PF = 1, t: 600 s do 24 h) Wzorcowanie – wielkości elektryczne Pośrednie generowanie kalibratorem z cewką prądową, cewkami prądowymi 1 V do 600 V; 10 A do 2250 A od 6 kWs do 116,6 GWs CMC 0,55 % Střídavá elektrická práce jednofázová i třífázová / Střídavá měřidla elektrické práce jednofázová i třífázová s proudovými vstupy (f: 45 Hz až 65 Hz, PF = 1, t: 600 s až 24 h) Kalibrace – elektrické veličiny Nepřímé generování kalibrátorem s proudovou cívkou, proudovými cívkami 1 V až 600 V; 10 A až 2250 A 6 kWs až 116,6 GWs CMC 0,55 % TP16 Energia elektryczna pradu przemiennego jedno- i trojfazowa / Liczniki energii elektrycznej pradu przemiennego jedno- i trojfazowe z wejsciami pradowymi (f: 45 Hz do 65 Hz, PF = 1, t: 600 s do 24 h) Wzorcowanie – wielkosci elektryczne Posrednie generowanie kalibratorem z cewka pradowa, cewkami pradowymi 1 V do 600 V; 10 A do 2250 A od 6 kWs do 116,6 GWs CMC 0,55 % Stridava elektricka prace jednofazova i trifazova / Stridava meridla elektricke prace jednofazova i trifazova s proudovymi vstupy (f: 45 Hz az 65 Hz, PF = 1, t: 600 s az 24 h) Kalibrace – elektricke veliciny Neprime generovani kalibratorem s proudovou civkou, proudovymi civkami 1 V az 600 V; 10 A az 2250 A 6 kWs az 116,6 GWs CMC 0,55 % TP16","search_en":"AC electrical work, single- and three-phase / AC electrical work meters, single-phase and three-phase with current inputs (f: 45 Hz to 65 Hz, PF = 1, t: 600 s to 24 h) Calibration – electrical quantities Indirect generation with a calibrator with current coil, current coils 1 V to 600 V; 10 A to 2250 A 6 kWs to 116,6 GWs CMC 0,55 % TP16","search_zh":"单相和三相交流电能 / 带电流输入的单相和三相交流电能表（f：45 Hz 至 65 Hz，PF = 1，t：600 s 至 24 h） 校准 – 电学量 用带电流线圈的校准器间接产生 1 V 至 600 V；10 A 至 2250 A 6 kWs 至 116,6 GWs CMC 0,55 % TP16","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0556cf24ab6d000efcbad98d","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"23","test_object":"Współczynnik odbicia / Pomiar dopasowania impedancji do impedancji 50 Ω","test_object_en":"Reflection coefficient / Measurement of impedance matching at 50 Ω impedance","test_object_zh":"反射系数 / 50 Ω 阻抗匹配测量","test_object_cs":"Činitel odrazu / Měření impedančního přizpůsobení na 50 Ω impedanci","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 MHz do 2 GHz","range":"od 0,00 do 0,10","cmc":"0,020"},{"name":"10 MHz do 2 GHz","range":"od 0,10 do 0,20","cmc":"0,030"},{"name":"10 MHz do 2 GHz","range":"od 0,20 do 0,30","cmc":"0,045"}],"parameters_en":[{"name":"10 MHz to 2 GHz","range":"0,00 to 0,10","cmc":"0,020"},{"name":"10 MHz to 2 GHz","range":"0,10 to 0,20","cmc":"0,030"},{"name":"10 MHz to 2 GHz","range":"0,20 to 0,30","cmc":"0,045"}],"parameters_zh":[{"name":"10 MHz 至 2 GHz","range":"0,00 至 0,10","cmc":"0,020"},{"name":"10 MHz 至 2 GHz","range":"0,10 至 0,20","cmc":"0,030"},{"name":"10 MHz 至 2 GHz","range":"0,20 至 0,30","cmc":"0,045"}],"parameters_cs":[{"name":"10 MHz až 2 GHz","range":"0,00 až 0,10","cmc":"0,020"},{"name":"10 MHz až 2 GHz","range":"0,10 až 0,20","cmc":"0,030"},{"name":"10 MHz až 2 GHz","range":"0,20 až 0,30","cmc":"0,045"}],"technique":"Pomiar mostkiem kierunkowym, złącze N, 50 Ω","technique_en":"Measurement with a directional bridge, N connector, 50 Ω","technique_zh":"用定向电桥测量，N 型连接器，50 Ω","technique_cs":"Měření směrovým mostem, N konektor, 50 Ω","techniques":["Pomiar mostkiem kierunkowym, złącze N, 50 Ω"],"techniques_en":["Measurement with a directional bridge, N connector, 50 Ω"],"techniques_zh":["用定向电桥测量，N 型连接器，50 Ω"],"techniques_cs":["Měření směrovým mostem, N konektor, 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 MHz do 2 GHz od 0,00 do 0,10 CMC 0,020\n10 MHz do 2 GHz od 0,10 do 0,20 CMC 0,030\n10 MHz do 2 GHz od 0,20 do 0,30 CMC 0,045\nPomiar mostkiem kierunkowym, złącze N, 50 Ω","reference":"TP17","norm_bases":["TP17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik odbicia / Pomiar dopasowania impedancji do impedancji 50 Ω Wzorcowanie – wielkości elektryczne Pomiar mostkiem kierunkowym, złącze N, 50 Ω 10 MHz do 2 GHz od 0,00 do 0,10 CMC 0,020 10 MHz do 2 GHz od 0,10 do 0,20 CMC 0,030 10 MHz do 2 GHz od 0,20 do 0,30 CMC 0,045 Činitel odrazu / Měření impedančního přizpůsobení na 50 Ω impedanci Kalibrace – elektrické veličiny Měření směrovým mostem, N konektor, 50 Ω 10 MHz až 2 GHz 0,00 až 0,10 CMC 0,020 10 MHz až 2 GHz 0,10 až 0,20 CMC 0,030 10 MHz až 2 GHz 0,20 až 0,30 CMC 0,045 TP17 Wspolczynnik odbicia / Pomiar dopasowania impedancji do impedancji 50 Ω Wzorcowanie – wielkosci elektryczne Pomiar mostkiem kierunkowym, zlacze N, 50 Ω 10 MHz do 2 GHz od 0,00 do 0,10 CMC 0,020 10 MHz do 2 GHz od 0,10 do 0,20 CMC 0,030 10 MHz do 2 GHz od 0,20 do 0,30 CMC 0,045 Cinitel odrazu / Mereni impedancniho prizpusobeni na 50 Ω impedanci Kalibrace – elektricke veliciny Mereni smerovym mostem, N konektor, 50 Ω 10 MHz az 2 GHz 0,00 az 0,10 CMC 0,020 10 MHz az 2 GHz 0,10 az 0,20 CMC 0,030 10 MHz az 2 GHz 0,20 az 0,30 CMC 0,045 TP17","search_en":"Reflection coefficient / Measurement of impedance matching at 50 Ω impedance Calibration – electrical quantities Measurement with a directional bridge, N connector, 50 Ω 10 MHz to 2 GHz 0,00 to 0,10 CMC 0,020 10 MHz to 2 GHz 0,10 to 0,20 CMC 0,030 10 MHz to 2 GHz 0,20 to 0,30 CMC 0,045 TP17","search_zh":"反射系数 / 50 Ω 阻抗匹配测量 校准 – 电学量 用定向电桥测量，N 型连接器，50 Ω 10 MHz 至 2 GHz 0,00 至 0,10 CMC 0,020 10 MHz 至 2 GHz 0,10 至 0,20 CMC 0,030 10 MHz 至 2 GHz 0,20 至 0,30 CMC 0,045 TP17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"924d255d89c23444cc5e4db8","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"23","test_object":"Współczynnik odbicia / Pomiar dopasowania impedancji do impedancji 50 Ω","test_object_en":"Reflection coefficient / Measurement of impedance matching at 50 Ω impedance","test_object_zh":"反射系数 / 50 Ω 阻抗匹配测量","test_object_cs":"Činitel odrazu / Měření impedančního přizpůsobení na 50 Ω impedanci","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"2 GHz do 18 GHz","range":"od 0,00 do 0,15","cmc":"0,070"},{"name":"2 GHz do 18 GHz","range":"od 0,15 do 0,20","cmc":"0,080"},{"name":"2 GHz do 18 GHz","range":"od 0,20 do 0,30","cmc":"0,10"}],"parameters_en":[{"name":"2 GHz to 18 GHz","range":"0,00 to 0,15","cmc":"0,070"},{"name":"2 GHz to 18 GHz","range":"0,15 to 0,20","cmc":"0,080"},{"name":"2 GHz to 18 GHz","range":"0,20 to 0,30","cmc":"0,10"}],"parameters_zh":[{"name":"2 GHz 至 18 GHz","range":"0,00 至 0,15","cmc":"0,070"},{"name":"2 GHz 至 18 GHz","range":"0,15 至 0,20","cmc":"0,080"},{"name":"2 GHz 至 18 GHz","range":"0,20 至 0,30","cmc":"0,10"}],"parameters_cs":[{"name":"2 GHz až 18 GHz","range":"0,00 až 0,15","cmc":"0,070"},{"name":"2 GHz až 18 GHz","range":"0,15 až 0,20","cmc":"0,080"},{"name":"2 GHz až 18 GHz","range":"0,20 až 0,30","cmc":"0,10"}],"technique":"Pomiar sprzęgaczem kierunkowym, złącze N, 50 Ω","technique_en":"Measurement with a directional coupling, N connector, 50 Ω","technique_zh":"用定向耦合器测量，N 型连接器，50 Ω","technique_cs":"Měření směrovou vazbou, N konektor, 50 Ω","techniques":["Pomiar sprzęgaczem kierunkowym, złącze N, 50 Ω"],"techniques_en":["Measurement with a directional coupling, N connector, 50 Ω"],"techniques_zh":["用定向耦合器测量，N 型连接器，50 Ω"],"techniques_cs":["Měření směrovou vazbou, N konektor, 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n2 GHz do 18 GHz od 0,00 do 0,15 CMC 0,070\n2 GHz do 18 GHz od 0,15 do 0,20 CMC 0,080\n2 GHz do 18 GHz od 0,20 do 0,30 CMC 0,10\nPomiar sprzęgaczem kierunkowym, złącze N, 50 Ω","reference":"TP17","norm_bases":["TP17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Współczynnik odbicia / Pomiar dopasowania impedancji do impedancji 50 Ω Wzorcowanie – wielkości elektryczne Pomiar sprzęgaczem kierunkowym, złącze N, 50 Ω 2 GHz do 18 GHz od 0,00 do 0,15 CMC 0,070 2 GHz do 18 GHz od 0,15 do 0,20 CMC 0,080 2 GHz do 18 GHz od 0,20 do 0,30 CMC 0,10 Činitel odrazu / Měření impedančního přizpůsobení na 50 Ω impedanci Kalibrace – elektrické veličiny Měření směrovou vazbou, N konektor, 50 Ω 2 GHz až 18 GHz 0,00 až 0,15 CMC 0,070 2 GHz až 18 GHz 0,15 až 0,20 CMC 0,080 2 GHz až 18 GHz 0,20 až 0,30 CMC 0,10 TP17 Wspolczynnik odbicia / Pomiar dopasowania impedancji do impedancji 50 Ω Wzorcowanie – wielkosci elektryczne Pomiar sprzegaczem kierunkowym, zlacze N, 50 Ω 2 GHz do 18 GHz od 0,00 do 0,15 CMC 0,070 2 GHz do 18 GHz od 0,15 do 0,20 CMC 0,080 2 GHz do 18 GHz od 0,20 do 0,30 CMC 0,10 Cinitel odrazu / Mereni impedancniho prizpusobeni na 50 Ω impedanci Kalibrace – elektricke veliciny Mereni smerovou vazbou, N konektor, 50 Ω 2 GHz az 18 GHz 0,00 az 0,15 CMC 0,070 2 GHz az 18 GHz 0,15 az 0,20 CMC 0,080 2 GHz az 18 GHz 0,20 az 0,30 CMC 0,10 TP17","search_en":"Reflection coefficient / Measurement of impedance matching at 50 Ω impedance Calibration – electrical quantities Measurement with a directional coupling, N connector, 50 Ω 2 GHz to 18 GHz 0,00 to 0,15 CMC 0,070 2 GHz to 18 GHz 0,15 to 0,20 CMC 0,080 2 GHz to 18 GHz 0,20 to 0,30 CMC 0,10 TP17","search_zh":"反射系数 / 50 Ω 阻抗匹配测量 校准 – 电学量 用定向耦合器测量，N 型连接器，50 Ω 2 GHz 至 18 GHz 0,00 至 0,15 CMC 0,070 2 GHz 至 18 GHz 0,15 至 0,20 CMC 0,080 2 GHz 至 18 GHz 0,20 至 0,30 CMC 0,10 TP17","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2a5cefb430d9cd45701e4cd","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"24","test_object":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa","test_object_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value","test_object_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值","test_object_cs":"Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0 Hz","range":"od 1 kV do 3 kV","cmc":"0,21 %"}],"parameters_en":[{"name":"0 Hz","range":"1 kV to 3 kV","cmc":"0,21 %"}],"parameters_zh":[{"name":"0 Hz","range":"1 kV 至 3 kV","cmc":"0,21 %"}],"parameters_cs":[{"name":"0 Hz","range":"1 kV až 3 kV","cmc":"0,21 %"}],"technique":"Pomiar multimetrem z dzielnikiem rezystancyjnym","technique_en":"Measurement with a multimeter with a resistance divider","technique_zh":"用带电阻分压器的万用表测量","technique_cs":"Měření multimetrem s odporovým děličem","techniques":["Pomiar multimetrem z dzielnikiem rezystancyjnym"],"techniques_en":["Measurement with a multimeter with a resistance divider"],"techniques_zh":["用带电阻分压器的万用表测量"],"techniques_cs":["Měření multimetrem s odporovým děličem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n0 Hz od 1 kV do 3 kV CMC 0,21 %\nPomiar multimetrem z dzielnikiem rezystancyjnym","reference":"TP18","norm_bases":["TP18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa Wzorcowanie – wielkości elektryczne Pomiar multimetrem z dzielnikiem rezystancyjnym 0 Hz od 1 kV do 3 kV CMC 0,21 % Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota Kalibrace – elektrické veličiny Měření multimetrem s odporovým děličem 0 Hz 1 kV až 3 kV CMC 0,21 % TP18 Napiecie powyzej 1000 V / Zrodla wysokiego napiecia stalego i przemiennego oraz generatory udarowe – wartosc szczytowa Wzorcowanie – wielkosci elektryczne Pomiar multimetrem z dzielnikiem rezystancyjnym 0 Hz od 1 kV do 3 kV CMC 0,21 % Napeti nad 1000 V / Stejnosmerne a stridave zdroje vysokeho napeti a razove generatory – vrcholova hodnota Kalibrace – elektricke veliciny Mereni multimetrem s odporovym delicem 0 Hz 1 kV az 3 kV CMC 0,21 % TP18","search_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value Calibration – electrical quantities Measurement with a multimeter with a resistance divider 0 Hz 1 kV to 3 kV CMC 0,21 % TP18","search_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值 校准 – 电学量 用带电阻分压器的万用表测量 0 Hz 1 kV 至 3 kV CMC 0,21 % TP18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad9325180e350feadecce284","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"24","test_object":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa","test_object_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value","test_object_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值","test_object_cs":"Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0 Hz","range":"od 3 kV do 90 kV","cmc":"0,20 %"},{"name":"0 Hz","range":"od 90 kV do 100 kV","cmc":"0,25 %"}],"parameters_en":[{"name":"0 Hz","range":"3 kV to 90 kV","cmc":"0,20 %"},{"name":"0 Hz","range":"90 kV to 100 kV","cmc":"0,25 %"}],"parameters_zh":[{"name":"0 Hz","range":"3 kV 至 90 kV","cmc":"0,20 %"},{"name":"0 Hz","range":"90 kV 至 100 kV","cmc":"0,25 %"}],"parameters_cs":[{"name":"0 Hz","range":"3 kV až 90 kV","cmc":"0,20 %"},{"name":"0 Hz","range":"90 kV až 100 kV","cmc":"0,25 %"}],"technique":"Pomiar sondą wysokonapięciową","technique_en":"High voltage probe measurement","technique_zh":"用高压探头测量","technique_cs":"Měření vysokonapěťovou sondou","techniques":["Pomiar sondą wysokonapięciową"],"techniques_en":["High voltage probe measurement"],"techniques_zh":["用高压探头测量"],"techniques_cs":["Měření vysokonapěťovou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Hz od 3 kV do 90 kV CMC 0,20 %\n0 Hz od 90 kV do 100 kV CMC 0,25 %\nPomiar sondą wysokonapięciową","reference":"TP18","norm_bases":["TP18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa Wzorcowanie – wielkości elektryczne Pomiar sondą wysokonapięciową 0 Hz od 3 kV do 90 kV CMC 0,20 % 0 Hz od 90 kV do 100 kV CMC 0,25 % Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota Kalibrace – elektrické veličiny Měření vysokonapěťovou sondou 0 Hz 3 kV až 90 kV CMC 0,20 % 0 Hz 90 kV až 100 kV CMC 0,25 % TP18 Napiecie powyzej 1000 V / Zrodla wysokiego napiecia stalego i przemiennego oraz generatory udarowe – wartosc szczytowa Wzorcowanie – wielkosci elektryczne Pomiar sonda wysokonapieciowa 0 Hz od 3 kV do 90 kV CMC 0,20 % 0 Hz od 90 kV do 100 kV CMC 0,25 % Napeti nad 1000 V / Stejnosmerne a stridave zdroje vysokeho napeti a razove generatory – vrcholova hodnota Kalibrace – elektricke veliciny Mereni vysokonapetovou sondou 0 Hz 3 kV az 90 kV CMC 0,20 % 0 Hz 90 kV az 100 kV CMC 0,25 % TP18","search_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value Calibration – electrical quantities High voltage probe measurement 0 Hz 3 kV to 90 kV CMC 0,20 % 0 Hz 90 kV to 100 kV CMC 0,25 % TP18","search_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值 校准 – 电学量 用高压探头测量 0 Hz 3 kV 至 90 kV CMC 0,20 % 0 Hz 90 kV 至 100 kV CMC 0,25 % TP18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"efe97f8f6db43104ef5246e4","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"24","test_object":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa","test_object_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value","test_object_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值","test_object_cs":"Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"do 75 MHz","range":"od 1 kV do 1,5 kV","cmc":"3 dB"},{"name":"do 10 MHz","range":"od 1 kV do 3 kV","cmc":"3 dB"},{"name":"do 1 MHz","range":"od 1 kV do 8 kV","cmc":"3 dB"},{"name":"do 500 kHz","range":"od 1 kV do 10 kV","cmc":"3 dB"},{"name":"czas narastania > 10 ns","range":"od 1 kV do 14 kV","cmc":"3 dB"}],"parameters_en":[{"name":"up to 75 MHz","range":"1 kV to 1,5 kV","cmc":"3 dB"},{"name":"up to 10 MHz","range":"1 kV to 3 kV","cmc":"3 dB"},{"name":"up to 1 MHz","range":"1 kV to 8 kV","cmc":"3 dB"},{"name":"up to 500 kHz","range":"1 kV to 10 kV","cmc":"3 dB"},{"name":"rise time > 10 ns","range":"1 kV to 14 kV","cmc":"3 dB"}],"parameters_zh":[{"name":"至 75 MHz","range":"1 kV 至 1,5 kV","cmc":"3 dB"},{"name":"至 10 MHz","range":"1 kV 至 3 kV","cmc":"3 dB"},{"name":"至 1 MHz","range":"1 kV 至 8 kV","cmc":"3 dB"},{"name":"至 500 kHz","range":"1 kV 至 10 kV","cmc":"3 dB"},{"name":"上升时间 > 10 ns","range":"1 kV 至 14 kV","cmc":"3 dB"}],"parameters_cs":[{"name":"do 75 MHz","range":"1 kV až 1,5 kV","cmc":"3 dB"},{"name":"do 10 MHz","range":"1 kV až 3 kV","cmc":"3 dB"},{"name":"do 1 MHz","range":"1 kV až 8 kV","cmc":"3 dB"},{"name":"do 500 kHz","range":"1 kV až 10 kV","cmc":"3 dB"},{"name":"doba náběhu > 10 ns","range":"1 kV až 14 kV","cmc":"3 dB"}],"technique":"Pomiar oscyloskopem z sondą WN","technique_en":"Measurement using an oscilloscope with a HV probe","technique_zh":"用带高压探头的示波器测量","technique_cs":"Měření osciloskopem s VN sondou","techniques":["Pomiar oscyloskopem z sondą WN"],"techniques_en":["Measurement using an oscilloscope with a HV probe"],"techniques_zh":["用带高压探头的示波器测量"],"techniques_cs":["Měření osciloskopem s VN sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\ndo 75 MHz od 1 kV do 1,5 kV CMC 3 dB\ndo 10 MHz od 1 kV do 3 kV CMC 3 dB\ndo 1 MHz od 1 kV do 8 kV CMC 3 dB\ndo 500 kHz od 1 kV do 10 kV CMC 3 dB\nczas narastania > 10 ns od 1 kV do 14 kV CMC 3 dB\nPomiar oscyloskopem z sondą WN","reference":"TP18","norm_bases":["TP18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa Wzorcowanie – wielkości elektryczne Pomiar oscyloskopem z sondą WN do 75 MHz od 1 kV do 1,5 kV CMC 3 dB do 10 MHz od 1 kV do 3 kV CMC 3 dB do 1 MHz od 1 kV do 8 kV CMC 3 dB do 500 kHz od 1 kV do 10 kV CMC 3 dB czas narastania > 10 ns od 1 kV do 14 kV CMC 3 dB Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota Kalibrace – elektrické veličiny Měření osciloskopem s VN sondou do 75 MHz 1 kV až 1,5 kV CMC 3 dB do 10 MHz 1 kV až 3 kV CMC 3 dB do 1 MHz 1 kV až 8 kV CMC 3 dB do 500 kHz 1 kV až 10 kV CMC 3 dB doba náběhu > 10 ns 1 kV až 14 kV CMC 3 dB TP18 Napiecie powyzej 1000 V / Zrodla wysokiego napiecia stalego i przemiennego oraz generatory udarowe – wartosc szczytowa Wzorcowanie – wielkosci elektryczne Pomiar oscyloskopem z sonda WN do 75 MHz od 1 kV do 1,5 kV CMC 3 dB do 10 MHz od 1 kV do 3 kV CMC 3 dB do 1 MHz od 1 kV do 8 kV CMC 3 dB do 500 kHz od 1 kV do 10 kV CMC 3 dB czas narastania > 10 ns od 1 kV do 14 kV CMC 3 dB Napeti nad 1000 V / Stejnosmerne a stridave zdroje vysokeho napeti a razove generatory – vrcholova hodnota Kalibrace – elektricke veliciny Mereni osciloskopem s VN sondou do 75 MHz 1 kV az 1,5 kV CMC 3 dB do 10 MHz 1 kV az 3 kV CMC 3 dB do 1 MHz 1 kV az 8 kV CMC 3 dB do 500 kHz 1 kV az 10 kV CMC 3 dB doba nabehu > 10 ns 1 kV az 14 kV CMC 3 dB TP18","search_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value Calibration – electrical quantities Measurement using an oscilloscope with a HV probe up to 75 MHz 1 kV to 1,5 kV CMC 3 dB up to 10 MHz 1 kV to 3 kV CMC 3 dB up to 1 MHz 1 kV to 8 kV CMC 3 dB up to 500 kHz 1 kV to 10 kV CMC 3 dB rise time > 10 ns 1 kV to 14 kV CMC 3 dB TP18","search_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值 校准 – 电学量 用带高压探头的示波器测量 至 75 MHz 1 kV 至 1,5 kV CMC 3 dB 至 10 MHz 1 kV 至 3 kV CMC 3 dB 至 1 MHz 1 kV 至 8 kV CMC 3 dB 至 500 kHz 1 kV 至 10 kV CMC 3 dB 上升时间 > 10 ns 1 kV 至 14 kV CMC 3 dB TP18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5062bb1342cdd5098ac2ac86","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"24","test_object":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa","test_object_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value","test_object_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值","test_object_cs":"Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 1 kV do 25 kV","cmc":"0,3 %"}],"parameters_en":[{"name":"50 Hz","range":"1 kV to 25 kV","cmc":"0,3 %"}],"parameters_zh":[{"name":"50 Hz","range":"1 kV 至 25 kV","cmc":"0,3 %"}],"parameters_cs":[{"name":"50 Hz","range":"1 kV až 25 kV","cmc":"0,3 %"}],"technique":"Pomiar z wykorzystaniem przekładnika pomiarowego","technique_en":"Measurement using a measuring transformer","technique_zh":"利用测量互感器测量","technique_cs":"Měření s využitím měřicího transformátoru","techniques":["Pomiar z wykorzystaniem przekładnika pomiarowego"],"techniques_en":["Measurement using a measuring transformer"],"techniques_zh":["利用测量互感器测量"],"techniques_cs":["Měření s využitím měřicího transformátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 1 kV do 25 kV CMC 0,3 %\nPomiar z wykorzystaniem przekładnika pomiarowego","reference":"TP18","norm_bases":["TP18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie powyżej 1000 V / Źródła wysokiego napięcia stałego i przemiennego oraz generatory udarowe – wartość szczytowa Wzorcowanie – wielkości elektryczne Pomiar z wykorzystaniem przekładnika pomiarowego 50 Hz od 1 kV do 25 kV CMC 0,3 % Napětí nad 1000 V / Stejnosměrné a střídavé zdroje vysokého napětí a rázové generátory – vrcholová hodnota Kalibrace – elektrické veličiny Měření s využitím měřicího transformátoru 50 Hz 1 kV až 25 kV CMC 0,3 % TP18 Napiecie powyzej 1000 V / Zrodla wysokiego napiecia stalego i przemiennego oraz generatory udarowe – wartosc szczytowa Wzorcowanie – wielkosci elektryczne Pomiar z wykorzystaniem przekladnika pomiarowego 50 Hz od 1 kV do 25 kV CMC 0,3 % Napeti nad 1000 V / Stejnosmerne a stridave zdroje vysokeho napeti a razove generatory – vrcholova hodnota Kalibrace – elektricke veliciny Mereni s vyuzitim mericiho transformatoru 50 Hz 1 kV az 25 kV CMC 0,3 % TP18","search_en":"Voltages above 1000 V / DC and AC high voltage sources and surge generators - peak value Calibration – electrical quantities Measurement using a measuring transformer 50 Hz 1 kV to 25 kV CMC 0,3 % TP18","search_zh":"1000 V 以上电压 / 直流和交流高压源及冲击发生器 – 峰值 校准 – 电学量 利用测量互感器测量 50 Hz 1 kV 至 25 kV CMC 0,3 % TP18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7fd1f183b9587709ead6e0ac","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"24","test_object":"Napięcie powyżej 1000 V / Mierniki wysokiego napięcia stałego i przemiennego, przetworniki wysokiego napięcia na prąd","test_object_en":"Voltages above 1000 V / DC and AC high voltage meters, HV voltage/current transducers","test_object_zh":"1000 V 以上电压 / 直流和交流高压测量仪器、高压/电流变换器","test_object_cs":"Napětí nad 1000 V / Stejnosměrná a střídavá měřidla vysokého napětí, převodníky vysokého napětí na proud","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 1 kV do 4 kV","cmc":"0,5 %"}],"parameters_en":[{"name":"50 Hz","range":"1 kV to 4 kV","cmc":"0,5 %"}],"parameters_zh":[{"name":"50 Hz","range":"1 kV 至 4 kV","cmc":"0,5 %"}],"parameters_cs":[{"name":"50 Hz","range":"1 kV až 4 kV","cmc":"0,5 %"}],"technique":"Generowanie z wykorzystaniem generatora i przekładnika pomiarowego","technique_en":"Generation using generator and HV measuring transformer","technique_zh":"利用发生器和测量互感器产生","technique_cs":"Generování s využitím generátoru a měřicího transformátoru","techniques":["Generowanie z wykorzystaniem generatora i przekładnika pomiarowego"],"techniques_en":["Generation using generator and HV measuring transformer"],"techniques_zh":["利用发生器和测量互感器产生"],"techniques_cs":["Generování s využitím generátoru a měřicího transformátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 1 kV do 4 kV CMC 0,5 %\nGenerowanie z wykorzystaniem generatora i przekładnika pomiarowego","reference":"TP18","norm_bases":["TP18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie powyżej 1000 V / Mierniki wysokiego napięcia stałego i przemiennego, przetworniki wysokiego napięcia na prąd Wzorcowanie – wielkości elektryczne Generowanie z wykorzystaniem generatora i przekładnika pomiarowego 50 Hz od 1 kV do 4 kV CMC 0,5 % Napětí nad 1000 V / Stejnosměrná a střídavá měřidla vysokého napětí, převodníky vysokého napětí na proud Kalibrace – elektrické veličiny Generování s využitím generátoru a měřicího transformátoru 50 Hz 1 kV až 4 kV CMC 0,5 % TP18 Napiecie powyzej 1000 V / Mierniki wysokiego napiecia stalego i przemiennego, przetworniki wysokiego napiecia na prad Wzorcowanie – wielkosci elektryczne Generowanie z wykorzystaniem generatora i przekladnika pomiarowego 50 Hz od 1 kV do 4 kV CMC 0,5 % Napeti nad 1000 V / Stejnosmerna a stridava meridla vysokeho napeti, prevodniky vysokeho napeti na proud Kalibrace – elektricke veliciny Generovani s vyuzitim generatoru a mericiho transformatoru 50 Hz 1 kV az 4 kV CMC 0,5 % TP18","search_en":"Voltages above 1000 V / DC and AC high voltage meters, HV voltage/current transducers Calibration – electrical quantities Generation using generator and HV measuring transformer 50 Hz 1 kV to 4 kV CMC 0,5 % TP18","search_zh":"1000 V 以上电压 / 直流和交流高压测量仪器、高压/电流变换器 校准 – 电学量 利用发生器和测量互感器产生 50 Hz 1 kV 至 4 kV CMC 0,5 % TP18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6bdc256d89a0634af93b3b18","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"24","test_object":"Napięcie powyżej 1000 V / Mierniki wysokiego napięcia stałego i przemiennego, przetworniki wysokiego napięcia na prąd","test_object_en":"Voltages above 1000 V / DC and AC high voltage meters, HV voltage/current transducers","test_object_zh":"1000 V 以上电压 / 直流和交流高压测量仪器、高压/电流变换器","test_object_cs":"Napětí nad 1000 V / Stejnosměrná a střídavá měřidla vysokého napětí, převodníky vysokého napětí na proud","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0 Hz","range":"od 1 kV do 30 kV","cmc":"0,25 %"}],"parameters_en":[{"name":"0 Hz","range":"1 kV to 30 kV","cmc":"0,25 %"}],"parameters_zh":[{"name":"0 Hz","range":"1 kV 至 30 kV","cmc":"0,25 %"}],"parameters_cs":[{"name":"0 Hz","range":"1 kV až 30 kV","cmc":"0,25 %"}],"technique":"Generowanie z wykorzystaniem generatora i dzielnika rezystancyjnego","technique_en":"Generation using a generator and resistor divider","technique_zh":"利用发生器和电阻分压器产生","technique_cs":"Generování s využitím generátoru a odporového děliče","techniques":["Generowanie z wykorzystaniem generatora i dzielnika rezystancyjnego"],"techniques_en":["Generation using a generator and resistor divider"],"techniques_zh":["利用发生器和电阻分压器产生"],"techniques_cs":["Generování s využitím generátoru a odporového děliče"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n0 Hz od 1 kV do 30 kV CMC 0,25 %\nGenerowanie z wykorzystaniem generatora i dzielnika rezystancyjnego","reference":"TP18","norm_bases":["TP18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie powyżej 1000 V / Mierniki wysokiego napięcia stałego i przemiennego, przetworniki wysokiego napięcia na prąd Wzorcowanie – wielkości elektryczne Generowanie z wykorzystaniem generatora i dzielnika rezystancyjnego 0 Hz od 1 kV do 30 kV CMC 0,25 % Napětí nad 1000 V / Stejnosměrná a střídavá měřidla vysokého napětí, převodníky vysokého napětí na proud Kalibrace – elektrické veličiny Generování s využitím generátoru a odporového děliče 0 Hz 1 kV až 30 kV CMC 0,25 % TP18 Napiecie powyzej 1000 V / Mierniki wysokiego napiecia stalego i przemiennego, przetworniki wysokiego napiecia na prad Wzorcowanie – wielkosci elektryczne Generowanie z wykorzystaniem generatora i dzielnika rezystancyjnego 0 Hz od 1 kV do 30 kV CMC 0,25 % Napeti nad 1000 V / Stejnosmerna a stridava meridla vysokeho napeti, prevodniky vysokeho napeti na proud Kalibrace – elektricke veliciny Generovani s vyuzitim generatoru a odporoveho delice 0 Hz 1 kV az 30 kV CMC 0,25 % TP18","search_en":"Voltages above 1000 V / DC and AC high voltage meters, HV voltage/current transducers Calibration – electrical quantities Generation using a generator and resistor divider 0 Hz 1 kV to 30 kV CMC 0,25 % TP18","search_zh":"1000 V 以上电压 / 直流和交流高压测量仪器、高压/电流变换器 校准 – 电学量 利用发生器和电阻分压器产生 0 Hz 1 kV 至 30 kV CMC 0,25 % TP18","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b1da34f0f6f5b21d065d3668","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"25","test_object":"Impedancja sieci / Przyrządy do badań instalacji elektrycznych i wzorce impedancji o charakterze rezystancyjnym","test_object_en":"Mains impedance / Instruments for the inspection of electrical installations and resistance-based impedance standards","test_object_zh":"电网阻抗 / 电气装置检测仪器和电阻性阻抗标准器","test_object_cs":"Impedance sítě / Přístroje pro revize elektrických sítí a etalony impedance odporového charakteru","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"0,16 Ω","cmc":"0,006 Ω"},{"name":"50 Hz","range":"od 0,17 Ω do 1 Ω","cmc":"0,5 % + 0,006 Ω"},{"name":"50 Hz","range":"od 1 Ω do 10 Ω","cmc":"0,3 % + 0,006 Ω"},{"name":"50 Hz","range":"od 10 Ω do 2 kΩ","cmc":"0,1 % + 0,006 Ω"}],"parameters_en":[{"name":"50 Hz","range":"0,16 Ω","cmc":"0,006 Ω"},{"name":"50 Hz","range":"0,17 Ω to 1 Ω","cmc":"0,5 % + 0,006 Ω"},{"name":"50 Hz","range":"1 Ω to 10 Ω","cmc":"0,3 % + 0,006 Ω"},{"name":"50 Hz","range":"10 Ω to 2 kΩ","cmc":"0,1 % + 0,006 Ω"}],"parameters_zh":[{"name":"50 Hz","range":"0,16 Ω","cmc":"0,006 Ω"},{"name":"50 Hz","range":"0,17 Ω 至 1 Ω","cmc":"0,5 % + 0,006 Ω"},{"name":"50 Hz","range":"1 Ω 至 10 Ω","cmc":"0,3 % + 0,006 Ω"},{"name":"50 Hz","range":"10 Ω 至 2 kΩ","cmc":"0,1 % + 0,006 Ω"}],"parameters_cs":[{"name":"50 Hz","range":"0,16 Ω","cmc":"0,006 Ω"},{"name":"50 Hz","range":"0,17 Ω až 1 Ω","cmc":"0,5 % + 0,006 Ω"},{"name":"50 Hz","range":"1 Ω až 10 Ω","cmc":"0,3 % + 0,006 Ω"},{"name":"50 Hz","range":"10 Ω až 2 kΩ","cmc":"0,1 % + 0,006 Ω"}],"technique":"Generowanie z wykorzystaniem gniazda wzorcowego","technique_en":"Generation using a reference socket","technique_zh":"利用标准插座产生","technique_cs":"Generování s využitím etalonové zásuvky","techniques":["Generowanie z wykorzystaniem gniazda wzorcowego"],"techniques_en":["Generation using a reference socket"],"techniques_zh":["利用标准插座产生"],"techniques_cs":["Generování s využitím etalonové zásuvky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz 0,16 Ω CMC 0,006 Ω\n50 Hz od 0,17 Ω do 1 Ω CMC 0,5 % + 0,006 Ω\n50 Hz od 1 Ω do 10 Ω CMC 0,3 % + 0,006 Ω\n50 Hz od 10 Ω do 2 kΩ CMC 0,1 % + 0,006 Ω\nGenerowanie z wykorzystaniem gniazda wzorcowego","reference":"TP6, TP27","norm_bases":["TP6","TP27"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja sieci / Przyrządy do badań instalacji elektrycznych i wzorce impedancji o charakterze rezystancyjnym Wzorcowanie – wielkości elektryczne Generowanie z wykorzystaniem gniazda wzorcowego 50 Hz 0,16 Ω CMC 0,006 Ω 50 Hz od 0,17 Ω do 1 Ω CMC 0,5 % + 0,006 Ω 50 Hz od 1 Ω do 10 Ω CMC 0,3 % + 0,006 Ω 50 Hz od 10 Ω do 2 kΩ CMC 0,1 % + 0,006 Ω Impedance sítě / Přístroje pro revize elektrických sítí a etalony impedance odporového charakteru Kalibrace – elektrické veličiny Generování s využitím etalonové zásuvky 50 Hz 0,16 Ω CMC 0,006 Ω 50 Hz 0,17 Ω až 1 Ω CMC 0,5 % + 0,006 Ω 50 Hz 1 Ω až 10 Ω CMC 0,3 % + 0,006 Ω 50 Hz 10 Ω až 2 kΩ CMC 0,1 % + 0,006 Ω TP6, TP27 Impedancja sieci / Przyrzady do badan instalacji elektrycznych i wzorce impedancji o charakterze rezystancyjnym Wzorcowanie – wielkosci elektryczne Generowanie z wykorzystaniem gniazda wzorcowego 50 Hz 0,16 Ω CMC 0,006 Ω 50 Hz od 0,17 Ω do 1 Ω CMC 0,5 % + 0,006 Ω 50 Hz od 1 Ω do 10 Ω CMC 0,3 % + 0,006 Ω 50 Hz od 10 Ω do 2 kΩ CMC 0,1 % + 0,006 Ω Impedance site / Pristroje pro revize elektrickych siti a etalony impedance odporoveho charakteru Kalibrace – elektricke veliciny Generovani s vyuzitim etalonove zasuvky 50 Hz 0,16 Ω CMC 0,006 Ω 50 Hz 0,17 Ω az 1 Ω CMC 0,5 % + 0,006 Ω 50 Hz 1 Ω az 10 Ω CMC 0,3 % + 0,006 Ω 50 Hz 10 Ω az 2 kΩ CMC 0,1 % + 0,006 Ω TP6, TP27","search_en":"Mains impedance / Instruments for the inspection of electrical installations and resistance-based impedance standards Calibration – electrical quantities Generation using a reference socket 50 Hz 0,16 Ω CMC 0,006 Ω 50 Hz 0,17 Ω to 1 Ω CMC 0,5 % + 0,006 Ω 50 Hz 1 Ω to 10 Ω CMC 0,3 % + 0,006 Ω 50 Hz 10 Ω to 2 kΩ CMC 0,1 % + 0,006 Ω TP6, TP27","search_zh":"电网阻抗 / 电气装置检测仪器和电阻性阻抗标准器 校准 – 电学量 利用标准插座产生 50 Hz 0,16 Ω CMC 0,006 Ω 50 Hz 0,17 Ω 至 1 Ω CMC 0,5 % + 0,006 Ω 50 Hz 1 Ω 至 10 Ω CMC 0,3 % + 0,006 Ω 50 Hz 10 Ω 至 2 kΩ CMC 0,1 % + 0,006 Ω TP6, TP27","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1ce04238f242b79c28e659f","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"26","test_object":"Przesunięcie fazowe / Źródła sygnału napięciowego przesuniętego fazowo","test_object_en":"Phase shift / Phase shifted voltage signal sources","test_object_zh":"相位差 / 相移电压信号源","test_object_cs":"Fázový posuv / Zdroje fázově posunutého signálu napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"2 Hz do 200 kHz; U₁ = U₂, gdy U₁: 10 mV do 50 V, U₂: 10 mV do 50 V lub U₁: 10 mV do 30 V, U₂: 1 V do 250 V","range":"od 0 ° do 360 °","cmc":"1°"}],"parameters_en":[{"name":"2 Hz to 200 kHz; U₁ = U₂, where U₁: 10 mV to 50 V, U₂: 10 mV to 50 V or U₁: 10 mV to 30 V, U₂: 1 V to 250 V","range":"0 ° to 360 °","cmc":"1°"}],"parameters_zh":[{"name":"2 Hz 至 200 kHz；U₁ = U₂，其中 U₁：10 mV 至 50 V，U₂：10 mV 至 50 V 或 U₁：10 mV 至 30 V，U₂：1 V 至 250 V","range":"0 ° 至 360 °","cmc":"1°"}],"parameters_cs":[{"name":"2 Hz až 200 kHz; U₁ = U₂, kdy U₁: 10 mV až 50 V, U₂: 10 mV až 50 V nebo U₁: 10 mV až 30 V, U₂: 1 V až 250 V","range":"0 ° až 360 °","cmc":"1°"}],"technique":"Pomiar miernikiem przesunięcia fazowego","technique_en":"Measurement by a phase shift meter","technique_zh":"用相位差计测量","technique_cs":"Měření měřidlem posunu fáze","techniques":["Pomiar miernikiem przesunięcia fazowego"],"techniques_en":["Measurement by a phase shift meter"],"techniques_zh":["用相位差计测量"],"techniques_cs":["Měření měřidlem posunu fáze"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n2 Hz do 200 kHz; U₁ = U₂, gdy U₁: 10 mV do 50 V, U₂: 10 mV do 50 V lub U₁: 10 mV do 30 V, U₂: 1 V do 250 V od 0 ° do 360 ° CMC 1°\nPomiar miernikiem przesunięcia fazowego","reference":"TP32","norm_bases":["TP32"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przesunięcie fazowe / Źródła sygnału napięciowego przesuniętego fazowo Wzorcowanie – wielkości elektryczne Pomiar miernikiem przesunięcia fazowego 2 Hz do 200 kHz; U₁ = U₂, gdy U₁: 10 mV do 50 V, U₂: 10 mV do 50 V lub U₁: 10 mV do 30 V, U₂: 1 V do 250 V od 0 ° do 360 ° CMC 1° Fázový posuv / Zdroje fázově posunutého signálu napětí Kalibrace – elektrické veličiny Měření měřidlem posunu fáze 2 Hz až 200 kHz; U₁ = U₂, kdy U₁: 10 mV až 50 V, U₂: 10 mV až 50 V nebo U₁: 10 mV až 30 V, U₂: 1 V až 250 V 0 ° až 360 ° CMC 1° TP32 Przesuniecie fazowe / Zrodla sygnalu napieciowego przesunietego fazowo Wzorcowanie – wielkosci elektryczne Pomiar miernikiem przesuniecia fazowego 2 Hz do 200 kHz; U₁ = U₂, gdy U₁: 10 mV do 50 V, U₂: 10 mV do 50 V lub U₁: 10 mV do 30 V, U₂: 1 V do 250 V od 0 ° do 360 ° CMC 1° Fazovy posuv / Zdroje fazove posunuteho signalu napeti Kalibrace – elektricke veliciny Mereni meridlem posunu faze 2 Hz az 200 kHz; U₁ = U₂, kdy U₁: 10 mV az 50 V, U₂: 10 mV az 50 V nebo U₁: 10 mV az 30 V, U₂: 1 V az 250 V 0 ° az 360 ° CMC 1° TP32","search_en":"Phase shift / Phase shifted voltage signal sources Calibration – electrical quantities Measurement by a phase shift meter 2 Hz to 200 kHz; U₁ = U₂, where U₁: 10 mV to 50 V, U₂: 10 mV to 50 V or U₁: 10 mV to 30 V, U₂: 1 V to 250 V 0 ° to 360 ° CMC 1° TP32","search_zh":"相位差 / 相移电压信号源 校准 – 电学量 用相位差计测量 2 Hz 至 200 kHz；U₁ = U₂，其中 U₁：10 mV 至 50 V，U₂：10 mV 至 50 V 或 U₁：10 mV 至 30 V，U₂：1 V 至 250 V 0 ° 至 360 ° CMC 1° TP32","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5af5228b36d692f022edcee3","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"26","test_object":"Przesunięcie fazowe / Mierniki sygnału napięciowego przesuniętego fazowo","test_object_en":"Phase shift / Phase shifted voltage signal meters","test_object_zh":"相位差 / 相移电压信号测量仪器","test_object_cs":"Fázový posuv / Měřidla fázově posunutého signálu napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"2 Hz do 200 kHz; U₁: 10 mV do 3 V, U₂: 10 mV do 3 V","range":"od 0 ° do 360 °","cmc":"1°"}],"parameters_en":[{"name":"2 Hz to 200 kHz; U₁: 10 mV to 3 V, U₂: 10 mV to 3 V","range":"0 ° to 360 °","cmc":"1°"}],"parameters_zh":[{"name":"2 Hz 至 200 kHz；U₁：10 mV 至 3 V，U₂：10 mV 至 3 V","range":"0 ° 至 360 °","cmc":"1°"}],"parameters_cs":[{"name":"2 Hz až 200 kHz; U₁: 10 mV až 3 V, U₂: 10 mV až 3 V","range":"0 ° až 360 °","cmc":"1°"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n2 Hz do 200 kHz; U₁: 10 mV do 3 V, U₂: 10 mV do 3 V od 0 ° do 360 ° CMC 1°\nBezpośrednie generowanie kalibratorem","reference":"TP32","norm_bases":["TP32"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przesunięcie fazowe / Mierniki sygnału napięciowego przesuniętego fazowo Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 2 Hz do 200 kHz; U₁: 10 mV do 3 V, U₂: 10 mV do 3 V od 0 ° do 360 ° CMC 1° Fázový posuv / Měřidla fázově posunutého signálu napětí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 2 Hz až 200 kHz; U₁: 10 mV až 3 V, U₂: 10 mV až 3 V 0 ° až 360 ° CMC 1° TP32 Przesuniecie fazowe / Mierniki sygnalu napieciowego przesunietego fazowo Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 2 Hz do 200 kHz; U₁: 10 mV do 3 V, U₂: 10 mV do 3 V od 0 ° do 360 ° CMC 1° Fazovy posuv / Meridla fazove posunuteho signalu napeti Kalibrace – elektricke veliciny Prime generovani kalibratorem 2 Hz az 200 kHz; U₁: 10 mV az 3 V, U₂: 10 mV az 3 V 0 ° az 360 ° CMC 1° TP32","search_en":"Phase shift / Phase shifted voltage signal meters Calibration – electrical quantities Direct generation with a calibrator 2 Hz to 200 kHz; U₁: 10 mV to 3 V, U₂: 10 mV to 3 V 0 ° to 360 ° CMC 1° TP32","search_zh":"相位差 / 相移电压信号测量仪器 校准 – 电学量 用校准器直接产生 2 Hz 至 200 kHz；U₁：10 mV 至 3 V，U₂：10 mV 至 3 V 0 ° 至 360 ° CMC 1° TP32","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f416eceeb44d5f6f3e3f417","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"27","test_object":"Pionowy współczynnik odchylania oscyloskopu","test_object_en":"Oscilloscope vertical deflection coefficient","test_object_zh":"示波器垂直偏转系数","test_object_cs":"Vertikální činitel vychylování osciloskopu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz","range":"od 12 mV do 55 V","cmc":"0,05 % + 20 µV"}],"parameters_en":[{"name":"1 kHz","range":"12 mV to 55 V","cmc":"0,05 % + 20 µV"}],"parameters_zh":[{"name":"1 kHz","range":"12 mV 至 55 V","cmc":"0,05 % + 20 µV"}],"parameters_cs":[{"name":"1 kHz","range":"12 mV až 55 V","cmc":"0,05 % + 20 µV"}],"technique":"Pomiar bezpośredni napięcia komutowanego multimetrem","technique_en":"Direct measurement of commutated voltage with a multimeter","technique_zh":"用万用表直接测量换向电压","technique_cs":"Přímé měření komutovaného napětí multimetrem","techniques":["Pomiar bezpośredni napięcia komutowanego multimetrem"],"techniques_en":["Direct measurement of commutated voltage with a multimeter"],"techniques_zh":["用万用表直接测量换向电压"],"techniques_cs":["Přímé měření komutovaného napětí multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n1 kHz od 12 mV do 55 V CMC 0,05 % + 20 µV\nPomiar bezpośredni napięcia komutowanego multimetrem","reference":"TP2, TP23","norm_bases":["TP2","TP23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pionowy współczynnik odchylania oscyloskopu Wzorcowanie – wielkości elektryczne Pomiar bezpośredni napięcia komutowanego multimetrem 1 kHz od 12 mV do 55 V CMC 0,05 % + 20 µV Vertikální činitel vychylování osciloskopu Kalibrace – elektrické veličiny Přímé měření komutovaného napětí multimetrem 1 kHz 12 mV až 55 V CMC 0,05 % + 20 µV TP2, TP23 Pionowy wspolczynnik odchylania oscyloskopu Wzorcowanie – wielkosci elektryczne Pomiar bezposredni napiecia komutowanego multimetrem 1 kHz od 12 mV do 55 V CMC 0,05 % + 20 µV Vertikalni cinitel vychylovani osciloskopu Kalibrace – elektricke veliciny Prime mereni komutovaneho napeti multimetrem 1 kHz 12 mV az 55 V CMC 0,05 % + 20 µV TP2, TP23","search_en":"Oscilloscope vertical deflection coefficient Calibration – electrical quantities Direct measurement of commutated voltage with a multimeter 1 kHz 12 mV to 55 V CMC 0,05 % + 20 µV TP2, TP23","search_zh":"示波器垂直偏转系数 校准 – 电学量 用万用表直接测量换向电压 1 kHz 12 mV 至 55 V CMC 0,05 % + 20 µV TP2, TP23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"396b80525e5ffa52f1e73f5b","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"27","test_object":"Pionowy współczynnik odchylania oscyloskopu","test_object_en":"Oscilloscope vertical deflection coefficient","test_object_zh":"示波器垂直偏转系数","test_object_cs":"Vertikální činitel vychylování osciloskopu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0 Hz","range":"od -300 V do 300 V","cmc":"0,005 % + 10 µV"},{"name":"1 kHz","range":"od 12 mV do 55 V","cmc":"0,30 % + 100 µV"}],"parameters_en":[{"name":"0 Hz","range":"-300 V to 300 V","cmc":"0,005 % + 10 µV"},{"name":"1 kHz","range":"12 mV to 55 V","cmc":"0,30 % + 100 µV"}],"parameters_zh":[{"name":"0 Hz","range":"-300 V 至 300 V","cmc":"0,005 % + 10 µV"},{"name":"1 kHz","range":"12 mV 至 55 V","cmc":"0,30 % + 100 µV"}],"parameters_cs":[{"name":"0 Hz","range":"-300 V až 300 V","cmc":"0,005 % + 10 µV"},{"name":"1 kHz","range":"12 mV až 55 V","cmc":"0,30 % + 100 µV"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Hz od -300 V do 300 V CMC 0,005 % + 10 µV\n1 kHz od 12 mV do 55 V CMC 0,30 % + 100 µV\nBezpośrednie generowanie kalibratorem","reference":"TP2, TP23","norm_bases":["TP2","TP23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pionowy współczynnik odchylania oscyloskopu Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 0 Hz od -300 V do 300 V CMC 0,005 % + 10 µV 1 kHz od 12 mV do 55 V CMC 0,30 % + 100 µV Vertikální činitel vychylování osciloskopu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 Hz -300 V až 300 V CMC 0,005 % + 10 µV 1 kHz 12 mV až 55 V CMC 0,30 % + 100 µV TP2, TP23 Pionowy wspolczynnik odchylania oscyloskopu Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 0 Hz od -300 V do 300 V CMC 0,005 % + 10 µV 1 kHz od 12 mV do 55 V CMC 0,30 % + 100 µV Vertikalni cinitel vychylovani osciloskopu Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 Hz -300 V az 300 V CMC 0,005 % + 10 µV 1 kHz 12 mV az 55 V CMC 0,30 % + 100 µV TP2, TP23","search_en":"Oscilloscope vertical deflection coefficient Calibration – electrical quantities Direct generation with a calibrator 0 Hz -300 V to 300 V CMC 0,005 % + 10 µV 1 kHz 12 mV to 55 V CMC 0,30 % + 100 µV TP2, TP23","search_zh":"示波器垂直偏转系数 校准 – 电学量 用校准器直接产生 0 Hz -300 V 至 300 V CMC 0,005 % + 10 µV 1 kHz 12 mV 至 55 V CMC 0,30 % + 100 µV TP2, TP23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"78c278f09108134f409bbe21","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / Liczniki m.cz. i w.cz., generatory m.cz. i w.cz., przetwornice częstotliwości, wzorce częstotliwości, komparatory częstotliwości i generatory impulsów","test_object_en":"Frequency / LF and HF counters, LF and HF generators, variable speed drives, frequency standards, frequency comparators and pulse generators","test_object_zh":"频率 / 低频和高频计数器、低频和高频发生器、变频器、频率标准、频率比较器和脉冲发生器","test_object_cs":"Frekvence / NF a VF čítače, NF a VF generátory, frekvenční měniče, etalony frekvence, komparátory frekvence a generátory impulsů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 0,005 Hz do 400 kHz","cmc":"3,3·10⁻⁴ / f"},{"name":"","range":"od 400 kHz do 1,5 GHz","cmc":"1,2·10⁻⁹"},{"name":"","range":"od 1,5 GHz do 18 GHz","cmc":"3·10⁻⁹"},{"name":"τ: 1 s do 2000 s","range":"1 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s do 15000 s","range":"1 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: więcej niż 15000 s","range":"1 MHz","cmc":"5·10⁻¹²"},{"name":"τ: 1 s do 2000 s","range":"5 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s do 15000 s","range":"5 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: więcej niż 15000 s","range":"5 MHz","cmc":"5·10⁻¹²"},{"name":"τ: 1 s do 2000 s","range":"10 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s do 15000 s","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: więcej niż 15000 s","range":"10 MHz","cmc":"5·10⁻¹²"}],"parameters_en":[{"name":"","range":"0,005 Hz to 400 kHz","cmc":"3,3·10⁻⁴ / f"},{"name":"","range":"400 kHz to 1,5 GHz","cmc":"1,2·10⁻⁹"},{"name":"","range":"1,5 GHz to 18 GHz","cmc":"3·10⁻⁹"},{"name":"τ: 1 s to 2000 s","range":"1 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s to 15000 s","range":"1 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: over 15000 s","range":"1 MHz","cmc":"5·10⁻¹²"},{"name":"τ: 1 s to 2000 s","range":"5 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s to 15000 s","range":"5 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: over 15000 s","range":"5 MHz","cmc":"5·10⁻¹²"},{"name":"τ: 1 s to 2000 s","range":"10 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s to 15000 s","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: over 15000 s","range":"10 MHz","cmc":"5·10⁻¹²"}],"parameters_zh":[{"name":"","range":"0,005 Hz 至 400 kHz","cmc":"3,3·10⁻⁴ / f"},{"name":"","range":"400 kHz 至 1,5 GHz","cmc":"1,2·10⁻⁹"},{"name":"","range":"1,5 GHz 至 18 GHz","cmc":"3·10⁻⁹"},{"name":"τ：1 s 至 2000 s","range":"1 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ：2000 s 至 15000 s","range":"1 MHz","cmc":"1·10⁻¹¹"},{"name":"τ：大于 15000 s","range":"1 MHz","cmc":"5·10⁻¹²"},{"name":"τ：1 s 至 2000 s","range":"5 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ：2000 s 至 15000 s","range":"5 MHz","cmc":"1·10⁻¹¹"},{"name":"τ：大于 15000 s","range":"5 MHz","cmc":"5·10⁻¹²"},{"name":"τ：1 s 至 2000 s","range":"10 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ：2000 s 至 15000 s","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"τ：大于 15000 s","range":"10 MHz","cmc":"5·10⁻¹²"}],"parameters_cs":[{"name":"","range":"0,005 Hz až 400 kHz","cmc":"3,3·10⁻⁴ / f"},{"name":"","range":"400 kHz až 1,5 GHz","cmc":"1,2·10⁻⁹"},{"name":"","range":"1,5 GHz až 18 GHz","cmc":"3·10⁻⁹"},{"name":"τ: 1 s až 2000 s","range":"1 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s až 15000 s","range":"1 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: více než 15000 s","range":"1 MHz","cmc":"5·10⁻¹²"},{"name":"τ: 1 s až 2000 s","range":"5 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s až 15000 s","range":"5 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: více než 15000 s","range":"5 MHz","cmc":"5·10⁻¹²"},{"name":"τ: 1 s až 2000 s","range":"10 MHz","cmc":"3·10⁻¹⁰"},{"name":"τ: 2000 s až 15000 s","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"τ: více než 15000 s","range":"10 MHz","cmc":"5·10⁻¹²"}],"technique":"Porównanie z wzorcem, pomiar","technique_en":"Comparison with a standard, measurement","technique_zh":"与标准比较、测量","technique_cs":"Porovnání s etalonem, měření","techniques":["Porównanie z wzorcem, pomiar"],"techniques_en":["Comparison with a standard, measurement"],"techniques_zh":["与标准比较、测量"],"techniques_cs":["Porovnání s etalonem, měření"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 0,005 Hz do 400 kHz CMC 3,3·10⁻⁴ / f\nod 400 kHz do 1,5 GHz CMC 1,2·10⁻⁹\nod 1,5 GHz do 18 GHz CMC 3·10⁻⁹\nτ: 1 s do 2000 s 1 MHz CMC 3·10⁻¹⁰\nτ: 2000 s do 15000 s 1 MHz CMC 1·10⁻¹¹\nτ: więcej niż 15000 s 1 MHz CMC 5·10⁻¹²\nτ: 1 s do 2000 s 5 MHz CMC 3·10⁻¹⁰\nτ: 2000 s do 15000 s 5 MHz CMC 1·10⁻¹¹\nτ: więcej niż 15000 s 5 MHz CMC 5·10⁻¹²\nτ: 1 s do 2000 s 10 MHz CMC 3·10⁻¹⁰\nτ: 2000 s do 15000 s 10 MHz CMC 1·10⁻¹¹\nτ: więcej niż 15000 s 10 MHz CMC 5·10⁻¹²\nPorównanie z wzorcem, pomiar","reference":"TP9, TP22","norm_bases":["TP9","TP22"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":"f – mierzona częstotliwość w Hz (uwaga 4).","note_en":"f – measured frequency in Hz (note 4).","note_zh":"f – 被测频率，单位 Hz（注 4）。","note_cs":"f – měřená frekvence v Hz (pozn. 4).","search_text":"Częstotliwość / Liczniki m.cz. i w.cz., generatory m.cz. i w.cz., przetwornice częstotliwości, wzorce częstotliwości, komparatory częstotliwości i generatory impulsów Wzorcowanie – wielkości czasu i częstotliwości Porównanie z wzorcem, pomiar od 0,005 Hz do 400 kHz CMC 3,3·10⁻⁴ / f od 400 kHz do 1,5 GHz CMC 1,2·10⁻⁹ od 1,5 GHz do 18 GHz CMC 3·10⁻⁹ τ: 1 s do 2000 s 1 MHz CMC 3·10⁻¹⁰ τ: 2000 s do 15000 s 1 MHz CMC 1·10⁻¹¹ τ: więcej niż 15000 s 1 MHz CMC 5·10⁻¹² τ: 1 s do 2000 s 5 MHz CMC 3·10⁻¹⁰ τ: 2000 s do 15000 s 5 MHz CMC 1·10⁻¹¹ τ: więcej niż 15000 s 5 MHz CMC 5·10⁻¹² τ: 1 s do 2000 s 10 MHz CMC 3·10⁻¹⁰ τ: 2000 s do 15000 s 10 MHz CMC 1·10⁻¹¹ τ: więcej niż 15000 s 10 MHz CMC 5·10⁻¹² Frekvence / NF a VF čítače, NF a VF generátory, frekvenční měniče, etalony frekvence, komparátory frekvence a generátory impulsů Kalibrace – veličiny času a frekvence Porovnání s etalonem, měření 0,005 Hz až 400 kHz CMC 3,3·10⁻⁴ / f 400 kHz až 1,5 GHz CMC 1,2·10⁻⁹ 1,5 GHz až 18 GHz CMC 3·10⁻⁹ τ: 1 s až 2000 s 1 MHz CMC 3·10⁻¹⁰ τ: 2000 s až 15000 s 1 MHz CMC 1·10⁻¹¹ τ: více než 15000 s 1 MHz CMC 5·10⁻¹² τ: 1 s až 2000 s 5 MHz CMC 3·10⁻¹⁰ τ: 2000 s až 15000 s 5 MHz CMC 1·10⁻¹¹ τ: více než 15000 s 5 MHz CMC 5·10⁻¹² τ: 1 s až 2000 s 10 MHz CMC 3·10⁻¹⁰ τ: 2000 s až 15000 s 10 MHz CMC 1·10⁻¹¹ τ: více než 15000 s 10 MHz CMC 5·10⁻¹² TP9, TP22 Czestotliwosc / Liczniki m.cz. i w.cz., generatory m.cz. i w.cz., przetwornice czestotliwosci, wzorce czestotliwosci, komparatory czestotliwosci i generatory impulsow Wzorcowanie – wielkosci czasu i czestotliwosci Porownanie z wzorcem, pomiar od 0,005 Hz do 400 kHz CMC 3,3·10⁻⁴ / f od 400 kHz do 1,5 GHz CMC 1,2·10⁻⁹ od 1,5 GHz do 18 GHz CMC 3·10⁻⁹ τ: 1 s do 2000 s 1 MHz CMC 3·10⁻¹⁰ τ: 2000 s do 15000 s 1 MHz CMC 1·10⁻¹¹ τ: wiecej niz 15000 s 1 MHz CMC 5·10⁻¹² τ: 1 s do 2000 s 5 MHz CMC 3·10⁻¹⁰ τ: 2000 s do 15000 s 5 MHz CMC 1·10⁻¹¹ τ: wiecej niz 15000 s 5 MHz CMC 5·10⁻¹² τ: 1 s do 2000 s 10 MHz CMC 3·10⁻¹⁰ τ: 2000 s do 15000 s 10 MHz CMC 1·10⁻¹¹ τ: wiecej niz 15000 s 10 MHz CMC 5·10⁻¹² Frekvence / NF a VF citace, NF a VF generatory, frekvencni menice, etalony frekvence, komparatory frekvence a generatory impulsu Kalibrace – veliciny casu a frekvence Porovnani s etalonem, mereni 0,005 Hz az 400 kHz CMC 3,3·10⁻⁴ / f 400 kHz az 1,5 GHz CMC 1,2·10⁻⁹ 1,5 GHz az 18 GHz CMC 3·10⁻⁹ τ: 1 s az 2000 s 1 MHz CMC 3·10⁻¹⁰ τ: 2000 s az 15000 s 1 MHz CMC 1·10⁻¹¹ τ: vice nez 15000 s 1 MHz CMC 5·10⁻¹² τ: 1 s az 2000 s 5 MHz CMC 3·10⁻¹⁰ τ: 2000 s az 15000 s 5 MHz CMC 1·10⁻¹¹ τ: vice nez 15000 s 5 MHz CMC 5·10⁻¹² τ: 1 s az 2000 s 10 MHz CMC 3·10⁻¹⁰ τ: 2000 s az 15000 s 10 MHz CMC 1·10⁻¹¹ τ: vice nez 15000 s 10 MHz CMC 5·10⁻¹² TP9, TP22","search_en":"Frequency / LF and HF counters, LF and HF generators, variable speed drives, frequency standards, frequency comparators and pulse generators Calibration – time and frequency quantities Comparison with a standard, measurement 0,005 Hz to 400 kHz CMC 3,3·10⁻⁴ / f 400 kHz to 1,5 GHz CMC 1,2·10⁻⁹ 1,5 GHz to 18 GHz CMC 3·10⁻⁹ τ: 1 s to 2000 s 1 MHz CMC 3·10⁻¹⁰ τ: 2000 s to 15000 s 1 MHz CMC 1·10⁻¹¹ τ: over 15000 s 1 MHz CMC 5·10⁻¹² τ: 1 s to 2000 s 5 MHz CMC 3·10⁻¹⁰ τ: 2000 s to 15000 s 5 MHz CMC 1·10⁻¹¹ τ: over 15000 s 5 MHz CMC 5·10⁻¹² τ: 1 s to 2000 s 10 MHz CMC 3·10⁻¹⁰ τ: 2000 s to 15000 s 10 MHz CMC 1·10⁻¹¹ τ: over 15000 s 10 MHz CMC 5·10⁻¹² TP9, TP22","search_zh":"频率 / 低频和高频计数器、低频和高频发生器、变频器、频率标准、频率比较器和脉冲发生器 校准 – 时间和频率量 与标准比较、测量 0,005 Hz 至 400 kHz CMC 3,3·10⁻⁴ / f 400 kHz 至 1,5 GHz CMC 1,2·10⁻⁹ 1,5 GHz 至 18 GHz CMC 3·10⁻⁹ τ：1 s 至 2000 s 1 MHz CMC 3·10⁻¹⁰ τ：2000 s 至 15000 s 1 MHz CMC 1·10⁻¹¹ τ：大于 15000 s 1 MHz CMC 5·10⁻¹² τ：1 s 至 2000 s 5 MHz CMC 3·10⁻¹⁰ τ：2000 s 至 15000 s 5 MHz CMC 1·10⁻¹¹ τ：大于 15000 s 5 MHz CMC 5·10⁻¹² τ：1 s 至 2000 s 10 MHz CMC 3·10⁻¹⁰ τ：2000 s 至 15000 s 10 MHz CMC 1·10⁻¹¹ τ：大于 15000 s 10 MHz CMC 5·10⁻¹² TP9, TP22","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e824620667e30d3331461b98","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / Liczniki m.cz. i w.cz., generatory m.cz. i w.cz., przetwornice częstotliwości, wzorce częstotliwości, komparatory częstotliwości i generatory impulsów","test_object_en":"Frequency / LF and HF counters, LF and HF generators, variable speed drives, frequency standards, frequency comparators and pulse generators","test_object_zh":"频率 / 低频和高频计数器、低频和高频发生器、变频器、频率标准、频率比较器和脉冲发生器","test_object_cs":"Frekvence / NF a VF čítače, NF a VF generátory, frekvenční měniče, etalony frekvence, komparátory frekvence a generátory impulsů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"","range":"od 1 Hz do 18 GHz","cmc":"1·10⁻⁹"}],"parameters_en":[{"name":"","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"","range":"1 Hz to 18 GHz","cmc":"1·10⁻⁹"}],"parameters_zh":[{"name":"","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"","range":"1 Hz 至 18 GHz","cmc":"1·10⁻⁹"}],"parameters_cs":[{"name":"","range":"10 MHz","cmc":"1·10⁻¹¹"},{"name":"","range":"1 Hz až 18 GHz","cmc":"1·10⁻⁹"}],"technique":"Generowanie sygnału odniesienia","technique_en":"Generation of reference signal","technique_zh":"产生参考信号","technique_cs":"Generování referenčního signálu","techniques":["Generowanie sygnału odniesienia"],"techniques_en":["Generation of reference signal"],"techniques_zh":["产生参考信号"],"techniques_cs":["Generování referenčního signálu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\n10 MHz CMC 1·10⁻¹¹\nod 1 Hz do 18 GHz CMC 1·10⁻⁹\nGenerowanie sygnału odniesienia","reference":"TP9, TP22","norm_bases":["TP9","TP22"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / Liczniki m.cz. i w.cz., generatory m.cz. i w.cz., przetwornice częstotliwości, wzorce częstotliwości, komparatory częstotliwości i generatory impulsów Wzorcowanie – wielkości czasu i częstotliwości Generowanie sygnału odniesienia 10 MHz CMC 1·10⁻¹¹ od 1 Hz do 18 GHz CMC 1·10⁻⁹ Frekvence / NF a VF čítače, NF a VF generátory, frekvenční měniče, etalony frekvence, komparátory frekvence a generátory impulsů Kalibrace – veličiny času a frekvence Generování referenčního signálu 10 MHz CMC 1·10⁻¹¹ 1 Hz až 18 GHz CMC 1·10⁻⁹ TP9, TP22 Czestotliwosc / Liczniki m.cz. i w.cz., generatory m.cz. i w.cz., przetwornice czestotliwosci, wzorce czestotliwosci, komparatory czestotliwosci i generatory impulsow Wzorcowanie – wielkosci czasu i czestotliwosci Generowanie sygnalu odniesienia 10 MHz CMC 1·10⁻¹¹ od 1 Hz do 18 GHz CMC 1·10⁻⁹ Frekvence / NF a VF citace, NF a VF generatory, frekvencni menice, etalony frekvence, komparatory frekvence a generatory impulsu Kalibrace – veliciny casu a frekvence Generovani referencniho signalu 10 MHz CMC 1·10⁻¹¹ 1 Hz az 18 GHz CMC 1·10⁻⁹ TP9, TP22","search_en":"Frequency / LF and HF counters, LF and HF generators, variable speed drives, frequency standards, frequency comparators and pulse generators Calibration – time and frequency quantities Generation of reference signal 10 MHz CMC 1·10⁻¹¹ 1 Hz to 18 GHz CMC 1·10⁻⁹ TP9, TP22","search_zh":"频率 / 低频和高频计数器、低频和高频发生器、变频器、频率标准、频率比较器和脉冲发生器 校准 – 时间和频率量 产生参考信号 10 MHz CMC 1·10⁻¹¹ 1 Hz 至 18 GHz CMC 1·10⁻⁹ TP9, TP22","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"414e39ebaf014c54703ef9ca","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"2","test_object":"Znaczniki czasu / Oscyloskopy, rejestratory zjawisk przejściowych","test_object_en":"Time stamps / Oscilloscopes, transient recorders","test_object_zh":"时标 / 示波器、瞬态记录仪","test_object_cs":"Časové značky / Osciloskopy, záznamníky přechodových jevů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 1,8 ns do 2,2 ns","cmc":"0,005 %"},{"name":"","range":"od 4,5 ns do 11 ns","cmc":"0,005 %"},{"name":"","range":"od 18 ns do 22 ns","cmc":"0,005 %"},{"name":"","range":"od 45 ns do 60 s","cmc":"0,005 %"},{"name":"","range":"1 s","cmc":"1·10⁻⁹"}],"parameters_en":[{"name":"","range":"1,8 ns to 2,2 ns","cmc":"0,005 %"},{"name":"","range":"4,5 ns to 11 ns","cmc":"0,005 %"},{"name":"","range":"18 ns to 22 ns","cmc":"0,005 %"},{"name":"","range":"45 ns to 60 s","cmc":"0,005 %"},{"name":"","range":"1 s","cmc":"1·10⁻⁹"}],"parameters_zh":[{"name":"","range":"1,8 ns 至 2,2 ns","cmc":"0,005 %"},{"name":"","range":"4,5 ns 至 11 ns","cmc":"0,005 %"},{"name":"","range":"18 ns 至 22 ns","cmc":"0,005 %"},{"name":"","range":"45 ns 至 60 s","cmc":"0,005 %"},{"name":"","range":"1 s","cmc":"1·10⁻⁹"}],"parameters_cs":[{"name":"","range":"1,8 ns až 2,2 ns","cmc":"0,005 %"},{"name":"","range":"4,5 ns až 11 ns","cmc":"0,005 %"},{"name":"","range":"18 ns až 22 ns","cmc":"0,005 %"},{"name":"","range":"45 ns až 60 s","cmc":"0,005 %"},{"name":"","range":"1 s","cmc":"1·10⁻⁹"}],"technique":"Bezpośrednie generowanie kalibratorem, generatorem","technique_en":"Direct generation by a calibrator, generator","technique_zh":"用校准器、发生器直接产生","technique_cs":"Přímé generování kalibrátorem, generátorem","techniques":["Bezpośrednie generowanie kalibratorem, generatorem"],"techniques_en":["Direct generation by a calibrator, generator"],"techniques_zh":["用校准器、发生器直接产生"],"techniques_cs":["Přímé generování kalibrátorem, generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 1,8 ns do 2,2 ns CMC 0,005 %\nod 4,5 ns do 11 ns CMC 0,005 %\nod 18 ns do 22 ns CMC 0,005 %\nod 45 ns do 60 s CMC 0,005 %\n1 s CMC 1·10⁻⁹\nBezpośrednie generowanie kalibratorem, generatorem","reference":"TP23","norm_bases":["TP23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Znaczniki czasu / Oscyloskopy, rejestratory zjawisk przejściowych Wzorcowanie – wielkości czasu i częstotliwości Bezpośrednie generowanie kalibratorem, generatorem od 1,8 ns do 2,2 ns CMC 0,005 % od 4,5 ns do 11 ns CMC 0,005 % od 18 ns do 22 ns CMC 0,005 % od 45 ns do 60 s CMC 0,005 % 1 s CMC 1·10⁻⁹ Časové značky / Osciloskopy, záznamníky přechodových jevů Kalibrace – veličiny času a frekvence Přímé generování kalibrátorem, generátorem 1,8 ns až 2,2 ns CMC 0,005 % 4,5 ns až 11 ns CMC 0,005 % 18 ns až 22 ns CMC 0,005 % 45 ns až 60 s CMC 0,005 % 1 s CMC 1·10⁻⁹ TP23 Znaczniki czasu / Oscyloskopy, rejestratory zjawisk przejsciowych Wzorcowanie – wielkosci czasu i czestotliwosci Bezposrednie generowanie kalibratorem, generatorem od 1,8 ns do 2,2 ns CMC 0,005 % od 4,5 ns do 11 ns CMC 0,005 % od 18 ns do 22 ns CMC 0,005 % od 45 ns do 60 s CMC 0,005 % 1 s CMC 1·10⁻⁹ Casove znacky / Osciloskopy, zaznamniky prechodovych jevu Kalibrace – veliciny casu a frekvence Prime generovani kalibratorem, generatorem 1,8 ns az 2,2 ns CMC 0,005 % 4,5 ns az 11 ns CMC 0,005 % 18 ns az 22 ns CMC 0,005 % 45 ns az 60 s CMC 0,005 % 1 s CMC 1·10⁻⁹ TP23","search_en":"Time stamps / Oscilloscopes, transient recorders Calibration – time and frequency quantities Direct generation by a calibrator, generator 1,8 ns to 2,2 ns CMC 0,005 % 4,5 ns to 11 ns CMC 0,005 % 18 ns to 22 ns CMC 0,005 % 45 ns to 60 s CMC 0,005 % 1 s CMC 1·10⁻⁹ TP23","search_zh":"时标 / 示波器、瞬态记录仪 校准 – 时间和频率量 用校准器、发生器直接产生 1,8 ns 至 2,2 ns CMC 0,005 % 4,5 ns 至 11 ns CMC 0,005 % 18 ns 至 22 ns CMC 0,005 % 45 ns 至 60 s CMC 0,005 % 1 s CMC 1·10⁻⁹ TP23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1445b51f2a625be1c3361ec4","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"3","test_object":"Czas narastania / Oscyloskopy, rejestratory zjawisk przejściowych","test_object_en":"Rise time / Oscilloscopes, transient recorders","test_object_zh":"上升时间 / 示波器、瞬态记录仪","test_object_cs":"Doba náběhu, / Osciloskopy, záznamníky přechodových jevů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"50 mV, 500 mV, 1 V","range":"0,1 ns","cmc":"0,1 ns"},{"name":"4,5 mV do 5,5 mV","range":"od 0,70 ns do 0,80 ns","cmc":"0,3 ns"},{"name":"9 mV do 11 mV","range":"od 0,70 ns do 0,80 ns","cmc":"0,2 ns"},{"name":"45 mV do 55 mV","range":"od 0,70 ns do 0,80 ns","cmc":"0,2 ns"},{"name":"90 mV do 110 mV","range":"od 0,70 ns do 0,80 ns","cmc":"0,2 ns"},{"name":"450 mV do 550 mV","range":"od 0,70 ns do 0,80 ns","cmc":"0,2 ns"},{"name":"0,9 V do 1,1 V","range":"od 0,70 ns do 0,80 ns","cmc":"0,2 ns"},{"name":"22,5 mV do 27,5 mV","range":"od 0,80 ns do 0,90 ns","cmc":"0,2 ns"},{"name":"225 mV do 275 mV","range":"od 0,80 ns do 0,90 ns","cmc":"0,2 ns"},{"name":"2,25 V do 2,75 V","range":"od 0,80 ns do 0,90 ns","cmc":"0,2 ns"}],"parameters_en":[{"name":"50 mV, 500 mV, 1 V","range":"0,1 ns","cmc":"0,1 ns"},{"name":"4,5 mV to 5,5 mV","range":"0,70 ns to 0,80 ns","cmc":"0,3 ns"},{"name":"9 mV to 11 mV","range":"0,70 ns to 0,80 ns","cmc":"0,2 ns"},{"name":"45 mV to 55 mV","range":"0,70 ns to 0,80 ns","cmc":"0,2 ns"},{"name":"90 mV to 110 mV","range":"0,70 ns to 0,80 ns","cmc":"0,2 ns"},{"name":"450 mV to 550 mV","range":"0,70 ns to 0,80 ns","cmc":"0,2 ns"},{"name":"0,9 V to 1,1 V","range":"0,70 ns to 0,80 ns","cmc":"0,2 ns"},{"name":"22,5 mV to 27,5 mV","range":"0,80 ns to 0,90 ns","cmc":"0,2 ns"},{"name":"225 mV to 275 mV","range":"0,80 ns to 0,90 ns","cmc":"0,2 ns"},{"name":"2,25 V to 2,75 V","range":"0,80 ns to 0,90 ns","cmc":"0,2 ns"}],"parameters_zh":[{"name":"50 mV, 500 mV, 1 V","range":"0,1 ns","cmc":"0,1 ns"},{"name":"4,5 mV 至 5,5 mV","range":"0,70 ns 至 0,80 ns","cmc":"0,3 ns"},{"name":"9 mV 至 11 mV","range":"0,70 ns 至 0,80 ns","cmc":"0,2 ns"},{"name":"45 mV 至 55 mV","range":"0,70 ns 至 0,80 ns","cmc":"0,2 ns"},{"name":"90 mV 至 110 mV","range":"0,70 ns 至 0,80 ns","cmc":"0,2 ns"},{"name":"450 mV 至 550 mV","range":"0,70 ns 至 0,80 ns","cmc":"0,2 ns"},{"name":"0,9 V 至 1,1 V","range":"0,70 ns 至 0,80 ns","cmc":"0,2 ns"},{"name":"22,5 mV 至 27,5 mV","range":"0,80 ns 至 0,90 ns","cmc":"0,2 ns"},{"name":"225 mV 至 275 mV","range":"0,80 ns 至 0,90 ns","cmc":"0,2 ns"},{"name":"2,25 V 至 2,75 V","range":"0,80 ns 至 0,90 ns","cmc":"0,2 ns"}],"parameters_cs":[{"name":"50 mV, 500 mV, 1 V","range":"0,1 ns","cmc":"0,1 ns"},{"name":"4,5 mV až 5,5 mV","range":"0,70 ns až 0,80 ns","cmc":"0,3 ns"},{"name":"9 mV až 11 mV","range":"0,70 ns až 0,80 ns","cmc":"0,2 ns"},{"name":"45 mV až 55 mV","range":"0,70 ns až 0,80 ns","cmc":"0,2 ns"},{"name":"90 mV až 110 mV","range":"0,70 ns až 0,80 ns","cmc":"0,2 ns"},{"name":"450 mV až 550 mV","range":"0,70 ns až 0,80 ns","cmc":"0,2 ns"},{"name":"0,9 V až 1,1 V","range":"0,70 ns až 0,80 ns","cmc":"0,2 ns"},{"name":"22,5 mV až 27,5 mV","range":"0,80 ns až 0,90 ns","cmc":"0,2 ns"},{"name":"225 mV až 275 mV","range":"0,80 ns až 0,90 ns","cmc":"0,2 ns"},{"name":"2,25 V až 2,75 V","range":"0,80 ns až 0,90 ns","cmc":"0,2 ns"}],"technique":"Bezpośrednie generowanie kalibratorem, generatorem","technique_en":"Direct generation by a calibrator, generator","technique_zh":"用校准器、发生器直接产生","technique_cs":"Přímé generování kalibrátorem, generátorem","techniques":["Bezpośrednie generowanie kalibratorem, generatorem"],"techniques_en":["Direct generation by a calibrator, generator"],"techniques_zh":["用校准器、发生器直接产生"],"techniques_cs":["Přímé generování kalibrátorem, generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\n50 mV, 500 mV, 1 V 0,1 ns CMC 0,1 ns\n4,5 mV do 5,5 mV od 0,70 ns do 0,80 ns CMC 0,3 ns\n9 mV do 11 mV od 0,70 ns do 0,80 ns CMC 0,2 ns\n45 mV do 55 mV od 0,70 ns do 0,80 ns CMC 0,2 ns\n90 mV do 110 mV od 0,70 ns do 0,80 ns CMC 0,2 ns\n450 mV do 550 mV od 0,70 ns do 0,80 ns CMC 0,2 ns\n0,9 V do 1,1 V od 0,70 ns do 0,80 ns CMC 0,2 ns\n22,5 mV do 27,5 mV od 0,80 ns do 0,90 ns CMC 0,2 ns\n225 mV do 275 mV od 0,80 ns do 0,90 ns CMC 0,2 ns\n2,25 V do 2,75 V od 0,80 ns do 0,90 ns CMC 0,2 ns\nBezpośrednie generowanie kalibratorem, generatorem","reference":"TP23","norm_bases":["TP23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czas narastania / Oscyloskopy, rejestratory zjawisk przejściowych Wzorcowanie – wielkości czasu i częstotliwości Bezpośrednie generowanie kalibratorem, generatorem 50 mV, 500 mV, 1 V 0,1 ns CMC 0,1 ns 4,5 mV do 5,5 mV od 0,70 ns do 0,80 ns CMC 0,3 ns 9 mV do 11 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 45 mV do 55 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 90 mV do 110 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 450 mV do 550 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 0,9 V do 1,1 V od 0,70 ns do 0,80 ns CMC 0,2 ns 22,5 mV do 27,5 mV od 0,80 ns do 0,90 ns CMC 0,2 ns 225 mV do 275 mV od 0,80 ns do 0,90 ns CMC 0,2 ns 2,25 V do 2,75 V od 0,80 ns do 0,90 ns CMC 0,2 ns Doba náběhu, / Osciloskopy, záznamníky přechodových jevů Kalibrace – veličiny času a frekvence Přímé generování kalibrátorem, generátorem 50 mV, 500 mV, 1 V 0,1 ns CMC 0,1 ns 4,5 mV až 5,5 mV 0,70 ns až 0,80 ns CMC 0,3 ns 9 mV až 11 mV 0,70 ns až 0,80 ns CMC 0,2 ns 45 mV až 55 mV 0,70 ns až 0,80 ns CMC 0,2 ns 90 mV až 110 mV 0,70 ns až 0,80 ns CMC 0,2 ns 450 mV až 550 mV 0,70 ns až 0,80 ns CMC 0,2 ns 0,9 V až 1,1 V 0,70 ns až 0,80 ns CMC 0,2 ns 22,5 mV až 27,5 mV 0,80 ns až 0,90 ns CMC 0,2 ns 225 mV až 275 mV 0,80 ns až 0,90 ns CMC 0,2 ns 2,25 V až 2,75 V 0,80 ns až 0,90 ns CMC 0,2 ns TP23 Czas narastania / Oscyloskopy, rejestratory zjawisk przejsciowych Wzorcowanie – wielkosci czasu i czestotliwosci Bezposrednie generowanie kalibratorem, generatorem 50 mV, 500 mV, 1 V 0,1 ns CMC 0,1 ns 4,5 mV do 5,5 mV od 0,70 ns do 0,80 ns CMC 0,3 ns 9 mV do 11 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 45 mV do 55 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 90 mV do 110 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 450 mV do 550 mV od 0,70 ns do 0,80 ns CMC 0,2 ns 0,9 V do 1,1 V od 0,70 ns do 0,80 ns CMC 0,2 ns 22,5 mV do 27,5 mV od 0,80 ns do 0,90 ns CMC 0,2 ns 225 mV do 275 mV od 0,80 ns do 0,90 ns CMC 0,2 ns 2,25 V do 2,75 V od 0,80 ns do 0,90 ns CMC 0,2 ns Doba nabehu, / Osciloskopy, zaznamniky prechodovych jevu Kalibrace – veliciny casu a frekvence Prime generovani kalibratorem, generatorem 50 mV, 500 mV, 1 V 0,1 ns CMC 0,1 ns 4,5 mV az 5,5 mV 0,70 ns az 0,80 ns CMC 0,3 ns 9 mV az 11 mV 0,70 ns az 0,80 ns CMC 0,2 ns 45 mV az 55 mV 0,70 ns az 0,80 ns CMC 0,2 ns 90 mV az 110 mV 0,70 ns az 0,80 ns CMC 0,2 ns 450 mV az 550 mV 0,70 ns az 0,80 ns CMC 0,2 ns 0,9 V az 1,1 V 0,70 ns az 0,80 ns CMC 0,2 ns 22,5 mV az 27,5 mV 0,80 ns az 0,90 ns CMC 0,2 ns 225 mV az 275 mV 0,80 ns az 0,90 ns CMC 0,2 ns 2,25 V az 2,75 V 0,80 ns az 0,90 ns CMC 0,2 ns TP23","search_en":"Rise time / Oscilloscopes, transient recorders Calibration – time and frequency quantities Direct generation by a calibrator, generator 50 mV, 500 mV, 1 V 0,1 ns CMC 0,1 ns 4,5 mV to 5,5 mV 0,70 ns to 0,80 ns CMC 0,3 ns 9 mV to 11 mV 0,70 ns to 0,80 ns CMC 0,2 ns 45 mV to 55 mV 0,70 ns to 0,80 ns CMC 0,2 ns 90 mV to 110 mV 0,70 ns to 0,80 ns CMC 0,2 ns 450 mV to 550 mV 0,70 ns to 0,80 ns CMC 0,2 ns 0,9 V to 1,1 V 0,70 ns to 0,80 ns CMC 0,2 ns 22,5 mV to 27,5 mV 0,80 ns to 0,90 ns CMC 0,2 ns 225 mV to 275 mV 0,80 ns to 0,90 ns CMC 0,2 ns 2,25 V to 2,75 V 0,80 ns to 0,90 ns CMC 0,2 ns TP23","search_zh":"上升时间 / 示波器、瞬态记录仪 校准 – 时间和频率量 用校准器、发生器直接产生 50 mV, 500 mV, 1 V 0,1 ns CMC 0,1 ns 4,5 mV 至 5,5 mV 0,70 ns 至 0,80 ns CMC 0,3 ns 9 mV 至 11 mV 0,70 ns 至 0,80 ns CMC 0,2 ns 45 mV 至 55 mV 0,70 ns 至 0,80 ns CMC 0,2 ns 90 mV 至 110 mV 0,70 ns 至 0,80 ns CMC 0,2 ns 450 mV 至 550 mV 0,70 ns 至 0,80 ns CMC 0,2 ns 0,9 V 至 1,1 V 0,70 ns 至 0,80 ns CMC 0,2 ns 22,5 mV 至 27,5 mV 0,80 ns 至 0,90 ns CMC 0,2 ns 225 mV 至 275 mV 0,80 ns 至 0,90 ns CMC 0,2 ns 2,25 V 至 2,75 V 0,80 ns 至 0,90 ns CMC 0,2 ns TP23","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75fe338349a6185fe28ee2cb","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"4","test_object":"Przedział czasu / Stopery, czasomierze, przyrządy do pomiaru czasu i źródła przedziałów czasu","test_object_en":"Time interval / Stopwatches, timers, time meters and time interval sources","test_object_zh":"时间间隔 / 秒表、定时器、计时器具和时间间隔源","test_object_cs":"Časový interval / Stopky, časovače, měřidla času a zdroje časových intervalů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"Przełączane elektronicznie","range":"od 0,1 s do 10⁵ s","cmc":"0,004 %"},{"name":"Przełączane ręcznie","range":"od 1 s do 90000 s","cmc":"0,20 s"}],"parameters_en":[{"name":"Electronically switched","range":"0,1 s to 10⁵ s","cmc":"0,004 %"},{"name":"Manually switched","range":"1 s to 90000 s","cmc":"0,20 s"}],"parameters_zh":[{"name":"电子触发","range":"0,1 s 至 10⁵ s","cmc":"0,004 %"},{"name":"手动触发","range":"1 s 至 90000 s","cmc":"0,20 s"}],"parameters_cs":[{"name":"Elektronicky spínané","range":"0,1 s až 10⁵ s","cmc":"0,004 %"},{"name":"Ručně spínané","range":"1 s až 90000 s","cmc":"0,20 s"}],"technique":"Pomiar bezpośredni czasu licznikiem, stoperem","technique_en":"Direct time measurement with a counter, stopwatch","technique_zh":"用计数器、秒表直接测量时间","technique_cs":"Přímé měření času čítačem, stopkami","techniques":["Pomiar bezpośredni czasu licznikiem, stoperem"],"techniques_en":["Direct time measurement with a counter, stopwatch"],"techniques_zh":["用计数器、秒表直接测量时间"],"techniques_cs":["Přímé měření času čítačem, stopkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nPrzełączane elektronicznie od 0,1 s do 10⁵ s CMC 0,004 %\nPrzełączane ręcznie od 1 s do 90000 s CMC 0,20 s\nPomiar bezpośredni czasu licznikiem, stoperem","reference":"TP33","norm_bases":["TP33"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / Stopery, czasomierze, przyrządy do pomiaru czasu i źródła przedziałów czasu Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni czasu licznikiem, stoperem Przełączane elektronicznie od 0,1 s do 10⁵ s CMC 0,004 % Przełączane ręcznie od 1 s do 90000 s CMC 0,20 s Časový interval / Stopky, časovače, měřidla času a zdroje časových intervalů Kalibrace – veličiny času a frekvence Přímé měření času čítačem, stopkami Elektronicky spínané 0,1 s až 10⁵ s CMC 0,004 % Ručně spínané 1 s až 90000 s CMC 0,20 s TP33 Przedzial czasu / Stopery, czasomierze, przyrzady do pomiaru czasu i zrodla przedzialow czasu Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni czasu licznikiem, stoperem Przelaczane elektronicznie od 0,1 s do 10⁵ s CMC 0,004 % Przelaczane recznie od 1 s do 90000 s CMC 0,20 s Casovy interval / Stopky, casovace, meridla casu a zdroje casovych intervalu Kalibrace – veliciny casu a frekvence Prime mereni casu citacem, stopkami Elektronicky spinane 0,1 s az 10⁵ s CMC 0,004 % Rucne spinane 1 s az 90000 s CMC 0,20 s TP33","search_en":"Time interval / Stopwatches, timers, time meters and time interval sources Calibration – time and frequency quantities Direct time measurement with a counter, stopwatch Electronically switched 0,1 s to 10⁵ s CMC 0,004 % Manually switched 1 s to 90000 s CMC 0,20 s TP33","search_zh":"时间间隔 / 秒表、定时器、计时器具和时间间隔源 校准 – 时间和频率量 用计数器、秒表直接测量时间 电子触发 0,1 s 至 10⁵ s CMC 0,004 % 手动触发 1 s 至 90000 s CMC 0,20 s TP33","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"235817bff74a526fa9d27c2a","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"4","test_object":"Przedział czasu / Stopery, czasomierze, przyrządy do pomiaru czasu i źródła przedziałów czasu","test_object_en":"Time interval / Stopwatches, timers, time meters and time interval sources","test_object_zh":"时间间隔 / 秒表、定时器、计时器具和时间间隔源","test_object_cs":"Časový interval / Stopky, časovače, měřidla času a zdroje časových intervalů","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 100 ps do 60 s","cmc":"0,2 % + 50 ps"}],"parameters_en":[{"name":"","range":"100 ps to 60 s","cmc":"0,2 % + 50 ps"}],"parameters_zh":[{"name":"","range":"100 ps 至 60 s","cmc":"0,2 % + 50 ps"}],"parameters_cs":[{"name":"","range":"100 ps až 60 s","cmc":"0,2 % + 50 ps"}],"technique":"Pomiar bezpośredni przedziałów czasu oscyloskopem","technique_en":"Direct measurement of time intervals with an oscilloscope","technique_zh":"用示波器直接测量时间间隔","technique_cs":"Přímé měření časových intervalů osciloskopem","techniques":["Pomiar bezpośredni przedziałów czasu oscyloskopem"],"techniques_en":["Direct measurement of time intervals with an oscilloscope"],"techniques_zh":["用示波器直接测量时间间隔"],"techniques_cs":["Přímé měření časových intervalů osciloskopem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nod 100 ps do 60 s CMC 0,2 % + 50 ps\nPomiar bezpośredni przedziałów czasu oscyloskopem","reference":"TP33","norm_bases":["TP33"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / Stopery, czasomierze, przyrządy do pomiaru czasu i źródła przedziałów czasu Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni przedziałów czasu oscyloskopem od 100 ps do 60 s CMC 0,2 % + 50 ps Časový interval / Stopky, časovače, měřidla času a zdroje časových intervalů Kalibrace – veličiny času a frekvence Přímé měření časových intervalů osciloskopem 100 ps až 60 s CMC 0,2 % + 50 ps TP33 Przedzial czasu / Stopery, czasomierze, przyrzady do pomiaru czasu i zrodla przedzialow czasu Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni przedzialow czasu oscyloskopem od 100 ps do 60 s CMC 0,2 % + 50 ps Casovy interval / Stopky, casovace, meridla casu a zdroje casovych intervalu Kalibrace – veliciny casu a frekvence Prime mereni casovych intervalu osciloskopem 100 ps az 60 s CMC 0,2 % + 50 ps TP33","search_en":"Time interval / Stopwatches, timers, time meters and time interval sources Calibration – time and frequency quantities Direct measurement of time intervals with an oscilloscope 100 ps to 60 s CMC 0,2 % + 50 ps TP33","search_zh":"时间间隔 / 秒表、定时器、计时器具和时间间隔源 校准 – 时间和频率量 用示波器直接测量时间间隔 100 ps 至 60 s CMC 0,2 % + 50 ps TP33","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e437e87090e3002a4fa4fe9d","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność / Higrometry analogowe i cyfrowe, przetworniki wilgotności i tory pomiarowe wilgotności wraz z sondami wilgotności","test_object_en":"Humidity / Analogue and digital hygrometers, humidity transducers and humidity measuring chains including humidity probes","test_object_zh":"湿度 / 模拟和数字湿度计、湿度变送器和湿度测量链（含湿度探头）","test_object_cs":"Vlhkost / Analogové a digitální vlhkoměry, převodníky vlhkosti a měřicí řetězce vlhkosti včetně vlhkostních sond","methodology":"Wzorcowanie – wielkości fizykochemiczne","methodology_en":"Calibration – physicochemical quantities","methodology_zh":"校准 – 物理化学量","methodology_cs":"Kalibrace – fyzikálně chemické veličiny","parameters":[{"name":"(10 do 50) °C","range":"od 5 % RH do 10 % RH","cmc":"2,2 %"},{"name":"(10 do 50) °C","range":"od 10 % RH do 50 % RH","cmc":"1,4 %"},{"name":"(10 do 50) °C","range":"od 50 % RH do 70 % RH","cmc":"1,6 %"},{"name":"(10 do 50) °C","range":"od 70 % RH do 90 % RH","cmc":"1,8 %"}],"parameters_en":[{"name":"(10 to 50) °C","range":"5 % RH to 10 % RH","cmc":"2,2 %"},{"name":"(10 to 50) °C","range":"10 % RH to 50 % RH","cmc":"1,4 %"},{"name":"(10 to 50) °C","range":"50 % RH to 70 % RH","cmc":"1,6 %"},{"name":"(10 to 50) °C","range":"70 % RH to 90 % RH","cmc":"1,8 %"}],"parameters_zh":[{"name":"（10 至 50）°C","range":"5 % RH 至 10 % RH","cmc":"2,2 %"},{"name":"（10 至 50）°C","range":"10 % RH 至 50 % RH","cmc":"1,4 %"},{"name":"（10 至 50）°C","range":"50 % RH 至 70 % RH","cmc":"1,6 %"},{"name":"（10 至 50）°C","range":"70 % RH 至 90 % RH","cmc":"1,8 %"}],"parameters_cs":[{"name":"(10 až 50) °C","range":"5 % RH až 10 % RH","cmc":"2,2 %"},{"name":"(10 až 50) °C","range":"10 % RH až 50 % RH","cmc":"1,4 %"},{"name":"(10 až 50) °C","range":"50 % RH až 70 % RH","cmc":"1,6 %"},{"name":"(10 až 50) °C","range":"70 % RH až 90 % RH","cmc":"1,8 %"}],"technique":"Porównanie z higrometrem wzorcowym w komorze klimatyzacyjnej","technique_en":"Comparison with a standard hygrometer in a conditioning chamber","technique_zh":"在气候箱中与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem v klimatizační komoře","techniques":["Porównanie z higrometrem wzorcowym w komorze klimatyzacyjnej"],"techniques_en":["Comparison with a standard hygrometer in a conditioning chamber"],"techniques_zh":["在气候箱中与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem v klimatizační komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne\nZakres:\n(10 do 50) °C od 5 % RH do 10 % RH CMC 2,2 %\n(10 do 50) °C od 10 % RH do 50 % RH CMC 1,4 %\n(10 do 50) °C od 50 % RH do 70 % RH CMC 1,6 %\n(10 do 50) °C od 70 % RH do 90 % RH CMC 1,8 %\nPorównanie z higrometrem wzorcowym w komorze klimatyzacyjnej","reference":"TP45","norm_bases":["TP45"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities","regulatory_area_zh":"被测量领域的CMC：物理化学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność / Higrometry analogowe i cyfrowe, przetworniki wilgotności i tory pomiarowe wilgotności wraz z sondami wilgotności Wzorcowanie – wielkości fizykochemiczne Porównanie z higrometrem wzorcowym w komorze klimatyzacyjnej (10 do 50) °C od 5 % RH do 10 % RH CMC 2,2 % (10 do 50) °C od 10 % RH do 50 % RH CMC 1,4 % (10 do 50) °C od 50 % RH do 70 % RH CMC 1,6 % (10 do 50) °C od 70 % RH do 90 % RH CMC 1,8 % Vlhkost / Analogové a digitální vlhkoměry, převodníky vlhkosti a měřicí řetězce vlhkosti včetně vlhkostních sond Kalibrace – fyzikálně chemické veličiny Porovnání s etalonovým vlhkoměrem v klimatizační komoře (10 až 50) °C 5 % RH až 10 % RH CMC 2,2 % (10 až 50) °C 10 % RH až 50 % RH CMC 1,4 % (10 až 50) °C 50 % RH až 70 % RH CMC 1,6 % (10 až 50) °C 70 % RH až 90 % RH CMC 1,8 % TP45 Wilgotnosc / Higrometry analogowe i cyfrowe, przetworniki wilgotnosci i tory pomiarowe wilgotnosci wraz z sondami wilgotnosci Wzorcowanie – wielkosci fizykochemiczne Porownanie z higrometrem wzorcowym w komorze klimatyzacyjnej (10 do 50) °C od 5 % RH do 10 % RH CMC 2,2 % (10 do 50) °C od 10 % RH do 50 % RH CMC 1,4 % (10 do 50) °C od 50 % RH do 70 % RH CMC 1,6 % (10 do 50) °C od 70 % RH do 90 % RH CMC 1,8 % Vlhkost / Analogove a digitalni vlhkomery, prevodniky vlhkosti a merici retezce vlhkosti vcetne vlhkostnich sond Kalibrace – fyzikalne chemicke veliciny Porovnani s etalonovym vlhkomerem v klimatizacni komore (10 az 50) °C 5 % RH az 10 % RH CMC 2,2 % (10 az 50) °C 10 % RH az 50 % RH CMC 1,4 % (10 az 50) °C 50 % RH az 70 % RH CMC 1,6 % (10 az 50) °C 70 % RH az 90 % RH CMC 1,8 % TP45","search_en":"Humidity / Analogue and digital hygrometers, humidity transducers and humidity measuring chains including humidity probes Calibration – physicochemical quantities Comparison with a standard hygrometer in a conditioning chamber (10 to 50) °C 5 % RH to 10 % RH CMC 2,2 % (10 to 50) °C 10 % RH to 50 % RH CMC 1,4 % (10 to 50) °C 50 % RH to 70 % RH CMC 1,6 % (10 to 50) °C 70 % RH to 90 % RH CMC 1,8 % TP45","search_zh":"湿度 / 模拟和数字湿度计、湿度变送器和湿度测量链（含湿度探头） 校准 – 物理化学量 在气候箱中与标准湿度计比较 （10 至 50）°C 5 % RH 至 10 % RH CMC 2,2 % （10 至 50）°C 10 % RH 至 50 % RH CMC 1,4 % （10 至 50）°C 50 % RH 至 70 % RH CMC 1,6 % （10 至 50）°C 70 % RH 至 90 % RH CMC 1,8 % TP45","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8a6be98d9e83041223752729","lab_id":"6ade8b5fff0682476170815a","country":"CZ","accr_number":"2273","accr_body":"ČIA","row_label":"2","test_object":"pH / Części elektryczne pH-metrów i symulatorów pH","test_object_en":"pH / Electrical parts of pH meters and pH simulators","test_object_zh":"pH / pH 计和 pH 模拟器的电气部分","test_object_cs":"pH / Elektrické části pH metrů a simulátorů pH","methodology":"Wzorcowanie – wielkości fizykochemiczne","methodology_en":"Calibration – physicochemical quantities","methodology_zh":"校准 – 物理化学量","methodology_cs":"Kalibrace – fyzikálně chemické veličiny","parameters":[{"name":"","range":"od 0 pH do 14 pH","cmc":"0,01 pH"}],"parameters_en":[{"name":"","range":"0 pH to 14 pH","cmc":"0,01 pH"}],"parameters_zh":[{"name":"","range":"0 pH 至 14 pH","cmc":"0,01 pH"}],"parameters_cs":[{"name":"","range":"0 pH až 14 pH","cmc":"0,01 pH"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne\nod 0 pH do 14 pH CMC 0,01 pH\nBezpośrednie generowanie kalibratorem","reference":"TP1, TP21","norm_bases":["TP1","TP21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities","regulatory_area_zh":"被测量领域的CMC：物理化学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"pH / Części elektryczne pH-metrów i symulatorów pH Wzorcowanie – wielkości fizykochemiczne Bezpośrednie generowanie kalibratorem od 0 pH do 14 pH CMC 0,01 pH pH / Elektrické části pH metrů a simulátorů pH Kalibrace – fyzikálně chemické veličiny Přímé generování kalibrátorem 0 pH až 14 pH CMC 0,01 pH TP1, TP21 pH / Czesci elektryczne pH-metrow i symulatorow pH Wzorcowanie – wielkosci fizykochemiczne Bezposrednie generowanie kalibratorem od 0 pH do 14 pH CMC 0,01 pH pH / Elektricke casti pH metru a simulatoru pH Kalibrace – fyzikalne chemicke veliciny Prime generovani kalibratorem 0 pH az 14 pH CMC 0,01 pH TP1, TP21","search_en":"pH / Electrical parts of pH meters and pH simulators Calibration – physicochemical quantities Direct generation with a calibrator 0 pH to 14 pH CMC 0,01 pH TP1, TP21","search_zh":"pH / pH 计和 pH 模拟器的电气部分 校准 – 物理化学量 用校准器直接产生 0 pH 至 14 pH CMC 0,01 pH TP1, TP21","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}