{"lab":{"_id":"6ade8b2cff06824761708101","accr_number":"2259","country":"CZ","accr_body":"ČIA","address":"Pelechov č. 62, 468 22 Železný Brod","categories":["metrology"],"city":"Železný Brod","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[15.2776821,50.6345667]},"map_coord":[50.6345667,15.2776821],"map_geo":"cai-mapa","methods_count":2,"name":"EXATHERM, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów do pomiaru temperatury i gęstości, w zakresie określonym w załączniku do świadectwa.","search_text":"exatherm, s.r.o. pelechov č. 62, 468 22 železný brod 2259","source_page_url":"https://www.cai.cz/?subjekt=2259-exatherm-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"05-02-2031","website":"www.exatherm.cz","certificate_date":"05.02.2026","certificate_no":"61/2026","certificate_replaces":"115/2021 z 11.02.2021","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów do pomiaru temperatury i gęstości, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of temperature and density measuring instruments, to the extent specified in the appendix to this Certificate.","zh":"温度和密度测量仪器的校准，范围见本证书附件。","cs":"Kalibrace měřidel teploty a hustoty, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące","lab_division_cs":"Kalibrační laboratoř","lab_division_en":"Calibration Laboratory","lab_division_zh":"校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"da48e44c54f06bb83872289df8fa4a9ed792322034d7db88b30af25c7fe096b0","source_pdf_url":"https://www.cai.cz/OA/pdf/61_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"eb1971b386e26055acc9d887","lab_id":"6ade8b2cff06824761708101","country":"CZ","accr_number":"2259","accr_body":"ČIA","row_label":"1","test_object":"Termometry szklane i wskazujące","test_object_en":"Glass and indicating thermometers","test_object_zh":"玻璃温度计和指示式温度计","test_object_cs":"Skleněné a indikační teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do -15 °C","cmc":"0,06 °C"},{"name":"","range":"od -15 °C do 50 °C","cmc":"0,04 °C"},{"name":"","range":"od 50 °C do 95 °C","cmc":"0,06 °C"},{"name":"","range":"od 95 °C do 200 °C","cmc":"0,14 °C"},{"name":"","range":"od 200 °C do 360 °C","cmc":"0,19 °C"}],"parameters_en":[{"name":"","range":"-30 °C to -15 °C","cmc":"0,06 °C"},{"name":"","range":"-15 °C to 50 °C","cmc":"0,04 °C"},{"name":"","range":"50 °C to 95 °C","cmc":"0,06 °C"},{"name":"","range":"95 °C to 200 °C","cmc":"0,14 °C"},{"name":"","range":"200 °C to 360 °C","cmc":"0,19 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 -15 °C","cmc":"0,06 °C"},{"name":"","range":"-15 °C 至 50 °C","cmc":"0,04 °C"},{"name":"","range":"50 °C 至 95 °C","cmc":"0,06 °C"},{"name":"","range":"95 °C 至 200 °C","cmc":"0,14 °C"},{"name":"","range":"200 °C 至 360 °C","cmc":"0,19 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až -15 °C","cmc":"0,06 °C"},{"name":"","range":"-15 °C až 50 °C","cmc":"0,04 °C"},{"name":"","range":"50 °C až 95 °C","cmc":"0,06 °C"},{"name":"","range":"95 °C až 200 °C","cmc":"0,14 °C"},{"name":"","range":"200 °C až 360 °C","cmc":"0,19 °C"}],"technique":"Porównanie z wzorcowym termometrem cyfrowym w cieczowej łaźni termostatycznej","technique_en":"Comparison with a standard digital thermometer in a liquid thermostatic bath","technique_zh":"在液体恒温槽中与标准数字温度计比较","technique_cs":"Porovnání s etalonovým digitálním teploměrem v kapalné termostatické lázni","techniques":["Porównanie z wzorcowym termometrem cyfrowym w cieczowej łaźni termostatycznej"],"techniques_en":["Comparison with a standard digital thermometer in a liquid thermostatic bath"],"techniques_zh":["在液体恒温槽中与标准数字温度计比较"],"techniques_cs":["Porovnání s etalonovým digitálním teploměrem v kapalné termostatické lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do -15 °C CMC 0,06 °C\nod -15 °C do 50 °C CMC 0,04 °C\nod 50 °C do 95 °C CMC 0,06 °C\nod 95 °C do 200 °C CMC 0,14 °C\nod 200 °C do 360 °C CMC 0,19 °C\nPorównanie z wzorcowym termometrem cyfrowym w cieczowej łaźni termostatycznej","reference":"IKP č.01/06 IKP č.03/06","norm_bases":["IKP č.01/06","IKP č.03/06"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane i wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem cyfrowym w cieczowej łaźni termostatycznej od -30 °C do -15 °C CMC 0,06 °C od -15 °C do 50 °C CMC 0,04 °C od 50 °C do 95 °C CMC 0,06 °C od 95 °C do 200 °C CMC 0,14 °C od 200 °C do 360 °C CMC 0,19 °C Skleněné a indikační teploměry Kalibrace – teplota Porovnání s etalonovým digitálním teploměrem v kapalné termostatické lázni -30 °C až -15 °C CMC 0,06 °C -15 °C až 50 °C CMC 0,04 °C 50 °C až 95 °C CMC 0,06 °C 95 °C až 200 °C CMC 0,14 °C 200 °C až 360 °C CMC 0,19 °C IKP č.01/06 IKP č.03/06 Termometry szklane i wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem cyfrowym w cieczowej lazni termostatycznej od -30 °C do -15 °C CMC 0,06 °C od -15 °C do 50 °C CMC 0,04 °C od 50 °C do 95 °C CMC 0,06 °C od 95 °C do 200 °C CMC 0,14 °C od 200 °C do 360 °C CMC 0,19 °C Sklenene a indikacni teplomery Kalibrace – teplota Porovnani s etalonovym digitalnim teplomerem v kapalne termostaticke lazni -30 °C az -15 °C CMC 0,06 °C -15 °C az 50 °C CMC 0,04 °C 50 °C az 95 °C CMC 0,06 °C 95 °C az 200 °C CMC 0,14 °C 200 °C az 360 °C CMC 0,19 °C IKP c.01/06 IKP c.03/06","search_en":"Glass and indicating thermometers Calibration – temperature Comparison with a standard digital thermometer in a liquid thermostatic bath -30 °C to -15 °C CMC 0,06 °C -15 °C to 50 °C CMC 0,04 °C 50 °C to 95 °C CMC 0,06 °C 95 °C to 200 °C CMC 0,14 °C 200 °C to 360 °C CMC 0,19 °C IKP č.01/06 IKP č.03/06","search_zh":"玻璃温度计和指示式温度计 校准 – 温度 在液体恒温槽中与标准数字温度计比较 -30 °C 至 -15 °C CMC 0,06 °C -15 °C 至 50 °C CMC 0,04 °C 50 °C 至 95 °C CMC 0,06 °C 95 °C 至 200 °C CMC 0,14 °C 200 °C 至 360 °C CMC 0,19 °C IKP č.01/06 IKP č.03/06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"143c4bad6058b6d61a80020d","lab_id":"6ade8b2cff06824761708101","country":"CZ","accr_number":"2259","accr_body":"ČIA","row_label":"1","test_object":"Gęstość cieczy","test_object_en":"Density of liquids","test_object_zh":"液体密度","test_object_cs":"Hustota kapalin","methodology":"Wzorcowanie – wielkości fizykochemiczne","methodology_en":"Calibration – physico-chemical quantities","methodology_zh":"校准 – 物理化学量","methodology_cs":"Kalibrace – fyzikálně chemické veličiny","parameters":[{"name":"areometry szklane","range":"od 700 kg/m³ do 2000 kg/m³","cmc":"0,26 kg/m³"},{"name":"alkoholomierze","range":"od 0 % obj. do 100 % obj.","cmc":"0,09 % obj."},{"name":"cukromierze (sacharometry)","range":"od 30 % hm. do 60 % hm.","cmc":"0,11 % hm."},{"name":"moszczomierze","range":"od 10 kg/hl do 30 kg/hl","cmc":"0,11 kg/hl"}],"parameters_en":[{"name":"glass hydrometers","range":"700 kg/m³ to 2000 kg/m³","cmc":"0,26 kg/m³"},{"name":"alcoholometers","range":"0 % obj. to 100 % obj.","cmc":"0,09 % obj."},{"name":"saccharometers","range":"30 % hm. to 60 % hm.","cmc":"0,11 % hm."},{"name":"must meters","range":"10 kg/hl to 30 kg/hl","cmc":"0,11 kg/hl"}],"parameters_zh":[{"name":"玻璃密度计","range":"700 kg/m³ 至 2000 kg/m³","cmc":"0,26 kg/m³"},{"name":"酒精计","range":"0 % obj. 至 100 % obj.","cmc":"0,09 % obj."},{"name":"糖度计","range":"30 % hm. 至 60 % hm.","cmc":"0,11 % hm."},{"name":"葡萄汁比重计","range":"10 kg/hl 至 30 kg/hl","cmc":"0,11 kg/hl"}],"parameters_cs":[{"name":"skleněné hustoměry","range":"700 kg/m³ až 2000 kg/m³","cmc":"0,26 kg/m³"},{"name":"lihoměry","range":"0 % obj. až 100 % obj.","cmc":"0,09 % obj."},{"name":"cukroměry","range":"30 % hm. až 60 % hm.","cmc":"0,11 % hm."},{"name":"moštoměry","range":"10 kg/hl až 30 kg/hl","cmc":"0,11 kg/hl"}],"technique":"Porównanie z areometrem wzorcowym","technique_en":"Comparison with a standard hydrometer","technique_zh":"与标准密度计比较","technique_cs":"Porovnání s etalonovým hustoměrem","techniques":["Porównanie z areometrem wzorcowym"],"techniques_en":["Comparison with a standard hydrometer"],"techniques_zh":["与标准密度计比较"],"techniques_cs":["Porovnání s etalonovým hustoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne\nZakres:\nareometry szklane od 700 kg/m³ do 2000 kg/m³ CMC 0,26 kg/m³\nalkoholomierze od 0 % obj. do 100 % obj. CMC 0,09 % obj.\ncukromierze (sacharometry) od 30 % hm. do 60 % hm. CMC 0,11 % hm.\nmoszczomierze od 10 kg/hl do 30 kg/hl CMC 0,11 kg/hl\nPorównanie z areometrem wzorcowym","reference":"IKP č.02/00","norm_bases":["IKP č.02/00"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne","regulatory_area_en":"CMC for the field of measured quantity: Physico-chemical quantities","regulatory_area_zh":"被测量领域的CMC：物理化学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gęstość cieczy Wzorcowanie – wielkości fizykochemiczne Porównanie z areometrem wzorcowym areometry szklane od 700 kg/m³ do 2000 kg/m³ CMC 0,26 kg/m³ alkoholomierze od 0 % obj. do 100 % obj. CMC 0,09 % obj. cukromierze (sacharometry) od 30 % hm. do 60 % hm. CMC 0,11 % hm. moszczomierze od 10 kg/hl do 30 kg/hl CMC 0,11 kg/hl Hustota kapalin Kalibrace – fyzikálně chemické veličiny Porovnání s etalonovým hustoměrem skleněné hustoměry 700 kg/m³ až 2000 kg/m³ CMC 0,26 kg/m³ lihoměry 0 % obj. až 100 % obj. CMC 0,09 % obj. cukroměry 30 % hm. až 60 % hm. CMC 0,11 % hm. moštoměry 10 kg/hl až 30 kg/hl CMC 0,11 kg/hl IKP č.02/00 Gestosc cieczy Wzorcowanie – wielkosci fizykochemiczne Porownanie z areometrem wzorcowym areometry szklane od 700 kg/m³ do 2000 kg/m³ CMC 0,26 kg/m³ alkoholomierze od 0 % obj. do 100 % obj. CMC 0,09 % obj. cukromierze (sacharometry) od 30 % hm. do 60 % hm. CMC 0,11 % hm. moszczomierze od 10 kg/hl do 30 kg/hl CMC 0,11 kg/hl Hustota kapalin Kalibrace – fyzikalne chemicke veliciny Porovnani s etalonovym hustomerem sklenene hustomery 700 kg/m³ az 2000 kg/m³ CMC 0,26 kg/m³ lihomery 0 % obj. az 100 % obj. CMC 0,09 % obj. cukromery 30 % hm. az 60 % hm. CMC 0,11 % hm. mostomery 10 kg/hl az 30 kg/hl CMC 0,11 kg/hl IKP c.02/00","search_en":"Density of liquids Calibration – physico-chemical quantities Comparison with a standard hydrometer glass hydrometers 700 kg/m³ to 2000 kg/m³ CMC 0,26 kg/m³ alcoholometers 0 % obj. to 100 % obj. CMC 0,09 % obj. saccharometers 30 % hm. to 60 % hm. CMC 0,11 % hm. must meters 10 kg/hl to 30 kg/hl CMC 0,11 kg/hl IKP č.02/00","search_zh":"液体密度 校准 – 物理化学量 与标准密度计比较 玻璃密度计 700 kg/m³ 至 2000 kg/m³ CMC 0,26 kg/m³ 酒精计 0 % obj. 至 100 % obj. CMC 0,09 % obj. 糖度计 30 % hm. 至 60 % hm. CMC 0,11 % hm. 葡萄汁比重计 10 kg/hl 至 30 kg/hl CMC 0,11 kg/hl IKP č.02/00","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}