{"lab":{"_id":"6acfffddff06824761705e04","country":"CZ","accr_number":"2258","accr_body":"ČIA","address":"K Vodárně 531, 257 22 Čerčany","categories":["metrology"],"city":"Čerčany","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.708075,49.8514151]},"map_coord":[49.8514151,14.708075],"map_geo":"cai-mapa","methods_count":5,"name":"ECOSOND s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: temperatura, wielkości elektryczne i wielkości fizykochemiczne, w zakresie określonym w załączniku do świadectwa.","search_text":"ecosond s.r.o. k vodárně 531, 257 22 čerčany 2258","source_page_url":"https://www.cai.cz/?subjekt=2258-ecosond-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"10-11-2030","website":"www.ecosond.cz","certificate_date":"10.11.2025","certificate_no":"567/2025","certificate_replaces":"679/2020 z 10.11.2020","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: temperatura, wielkości elektryczne i wielkości fizykochemiczne, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the field of temperature, electrical quantities, and physical and chemical quantities to the extent as specified in the appendix to this Certificate.","zh":"温度、电学量和物理化学量领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru teplota, elektrické veličiny a fyzikálně chemické veličiny, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcowania termopar i sond tlenowych","lab_division_cs":"Laboratoř kalibrace termočlánků a kyslíkových sond","lab_division_en":"Thermocouple and Oxygen Probe Calibration Laboratory","lab_division_zh":"热电偶和氧探头校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"% C","pl":"zawartość węgla","en":"carbon content","zh":"碳含量","cs":"obsah uhlíku"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"37f50457760030abaf680676b423faf07daf58687f67e50af37208a5d2734c06","source_pdf_url":"https://www.cai.cz/OA/pdf/567_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/567_2025_EN.pdf"},"methods":[{"_id":"d0364434b7617b22e7c22928","lab_id":"6acfffddff06824761705e04","country":"CZ","accr_number":"2258","accr_body":"ČIA","row_label":"1","test_object":"Termopary ze stopów platyny\nTermopary z metali nieszlachetnych","test_object_en":"Platinum alloy thermocouples\nThermocouples made of base metals","test_object_zh":"铂合金热电偶\n贱金属热电偶","test_object_cs":"Termočlánky z platinových slitin\nTermočlánky z obecných kovů","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"termopary ze stopów platyny","range":"od 50 °C do 500 °C","cmc":"1,8 °C"},{"name":"termopary ze stopów platyny","range":"od 500 °C do 1100 °C","cmc":"1,9 °C"},{"name":"termopary ze stopów platyny","range":"od 1100 °C do 1300 °C","cmc":"2,4 °C"},{"name":"termopary z metali nieszlachetnych","range":"od 50 °C do 1100 °C","cmc":"2,0 °C"},{"name":"termopary z metali nieszlachetnych","range":"od 1100 °C do 1300 °C","cmc":"2,4 °C"}],"parameters_en":[{"name":"platinum alloy thermocouples","range":"50 °C to 500 °C","cmc":"1,8 °C"},{"name":"platinum alloy thermocouples","range":"500 °C to 1100 °C","cmc":"1,9 °C"},{"name":"platinum alloy thermocouples","range":"1100 °C to 1300 °C","cmc":"2,4 °C"},{"name":"thermocouples made of base metals","range":"50 °C to 1100 °C","cmc":"2,0 °C"},{"name":"thermocouples made of base metals","range":"1100 °C to 1300 °C","cmc":"2,4 °C"}],"parameters_zh":[{"name":"铂合金热电偶","range":"50 °C 至 500 °C","cmc":"1,8 °C"},{"name":"铂合金热电偶","range":"500 °C 至 1100 °C","cmc":"1,9 °C"},{"name":"铂合金热电偶","range":"1100 °C 至 1300 °C","cmc":"2,4 °C"},{"name":"贱金属热电偶","range":"50 °C 至 1100 °C","cmc":"2,0 °C"},{"name":"贱金属热电偶","range":"1100 °C 至 1300 °C","cmc":"2,4 °C"}],"parameters_cs":[{"name":"termočlánky z platinových slitin","range":"50 °C až 500 °C","cmc":"1,8 °C"},{"name":"termočlánky z platinových slitin","range":"500 °C až 1100 °C","cmc":"1,9 °C"},{"name":"termočlánky z platinových slitin","range":"1100 °C až 1300 °C","cmc":"2,4 °C"},{"name":"termočlánky z obecných kovů","range":"50 °C až 1100 °C","cmc":"2,0 °C"},{"name":"termočlánky z obecných kovů","range":"1100 °C až 1300 °C","cmc":"2,4 °C"}],"technique":"Porównanie z termoparą wzorcową w piecu wzorcującym","technique_en":"Comparison with a reference thermocouple in a calibrating oven","technique_zh":"在校准炉中与标准热电偶比较","technique_cs":"Porovnání s etalonovým termočlánkem v kalibrační pícce","techniques":["Porównanie z termoparą wzorcową w piecu wzorcującym"],"techniques_en":["Comparison with a reference thermocouple in a calibrating oven"],"techniques_zh":["在校准炉中与标准热电偶比较"],"techniques_cs":["Porovnání s etalonovým termočlánkem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\ntermopary ze stopów platyny od 50 °C do 500 °C CMC 1,8 °C\ntermopary ze stopów platyny od 500 °C do 1100 °C CMC 1,9 °C\ntermopary ze stopów platyny od 1100 °C do 1300 °C CMC 2,4 °C\ntermopary z metali nieszlachetnych od 50 °C do 1100 °C CMC 2,0 °C\ntermopary z metali nieszlachetnych od 1100 °C do 1300 °C CMC 2,4 °C\nPorównanie z termoparą wzorcową w piecu wzorcującym","reference":"10-01","norm_bases":["10-01"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopary ze stopów platyny\nTermopary z metali nieszlachetnych Wzorcowanie – temperatura Porównanie z termoparą wzorcową w piecu wzorcującym termopary ze stopów platyny od 50 °C do 500 °C CMC 1,8 °C termopary ze stopów platyny od 500 °C do 1100 °C CMC 1,9 °C termopary ze stopów platyny od 1100 °C do 1300 °C CMC 2,4 °C termopary z metali nieszlachetnych od 50 °C do 1100 °C CMC 2,0 °C termopary z metali nieszlachetnych od 1100 °C do 1300 °C CMC 2,4 °C Termočlánky z platinových slitin\nTermočlánky z obecných kovů Kalibrace – teplota Porovnání s etalonovým termočlánkem v kalibrační pícce termočlánky z platinových slitin 50 °C až 500 °C CMC 1,8 °C termočlánky z platinových slitin 500 °C až 1100 °C CMC 1,9 °C termočlánky z platinových slitin 1100 °C až 1300 °C CMC 2,4 °C termočlánky z obecných kovů 50 °C až 1100 °C CMC 2,0 °C termočlánky z obecných kovů 1100 °C až 1300 °C CMC 2,4 °C 10-01 Termopary ze stopow platyny\nTermopary z metali nieszlachetnych Wzorcowanie – temperatura Porownanie z termopara wzorcowa w piecu wzorcujacym termopary ze stopow platyny od 50 °C do 500 °C CMC 1,8 °C termopary ze stopow platyny od 500 °C do 1100 °C CMC 1,9 °C termopary ze stopow platyny od 1100 °C do 1300 °C CMC 2,4 °C termopary z metali nieszlachetnych od 50 °C do 1100 °C CMC 2,0 °C termopary z metali nieszlachetnych od 1100 °C do 1300 °C CMC 2,4 °C Termoclanky z platinovych slitin\nTermoclanky z obecnych kovu Kalibrace – teplota Porovnani s etalonovym termoclankem v kalibracni picce termoclanky z platinovych slitin 50 °C az 500 °C CMC 1,8 °C termoclanky z platinovych slitin 500 °C az 1100 °C CMC 1,9 °C termoclanky z platinovych slitin 1100 °C az 1300 °C CMC 2,4 °C termoclanky z obecnych kovu 50 °C az 1100 °C CMC 2,0 °C termoclanky z obecnych kovu 1100 °C az 1300 °C CMC 2,4 °C 10-01","search_en":"Platinum alloy thermocouples\nThermocouples made of base metals Calibration – temperature Comparison with a reference thermocouple in a calibrating oven platinum alloy thermocouples 50 °C to 500 °C CMC 1,8 °C platinum alloy thermocouples 500 °C to 1100 °C CMC 1,9 °C platinum alloy thermocouples 1100 °C to 1300 °C CMC 2,4 °C thermocouples made of base metals 50 °C to 1100 °C CMC 2,0 °C thermocouples made of base metals 1100 °C to 1300 °C CMC 2,4 °C 10-01","search_zh":"铂合金热电偶\n贱金属热电偶 校准 – 温度 在校准炉中与标准热电偶比较 铂合金热电偶 50 °C 至 500 °C CMC 1,8 °C 铂合金热电偶 500 °C 至 1100 °C CMC 1,9 °C 铂合金热电偶 1100 °C 至 1300 °C CMC 2,4 °C 贱金属热电偶 50 °C 至 1100 °C CMC 2,0 °C 贱金属热电偶 1100 °C 至 1300 °C CMC 2,4 °C 10-01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a942f5cfff1511868925789d","lab_id":"6acfffddff06824761705e04","country":"CZ","accr_number":"2258","accr_body":"ČIA","row_label":"2","test_object":"Układy regulacji komór termicznych pełniące funkcję przyrządu pomiarowego","test_object_en":"Thermal chamber control systems in the function of a measuring instrument","test_object_zh":"作为测量器具使用的温箱控制系统","test_object_cs":"Regulační systémy teplotních komor ve funkci měřidla","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 50 °C do 1300 °C","cmc":"2,8 °C"}],"parameters_en":[{"name":"","range":"50 °C to 1300 °C","cmc":"2,8 °C"}],"parameters_zh":[{"name":"","range":"50 °C 至 1300 °C","cmc":"2,8 °C"}],"parameters_cs":[{"name":"","range":"50 °C až 1300 °C","cmc":"2,8 °C"}],"technique":"Porównanie z termometrem wzorcowym","technique_en":"Comparison with a reference thermometer","technique_zh":"与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem","techniques":["Porównanie z termometrem wzorcowym"],"techniques_en":["Comparison with a reference thermometer"],"techniques_zh":["与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 50 °C do 1300 °C CMC 2,8 °C\nPorównanie z termometrem wzorcowym","reference":"10-04","norm_bases":["10-04"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Układy regulacji komór termicznych pełniące funkcję przyrządu pomiarowego Wzorcowanie – temperatura Porównanie z termometrem wzorcowym od 50 °C do 1300 °C CMC 2,8 °C Regulační systémy teplotních komor ve funkci měřidla Kalibrace – teplota Porovnání s etalonovým teploměrem 50 °C až 1300 °C CMC 2,8 °C 10-04 Uklady regulacji komor termicznych pelniace funkcje przyrzadu pomiarowego Wzorcowanie – temperatura Porownanie z termometrem wzorcowym od 50 °C do 1300 °C CMC 2,8 °C Regulacni systemy teplotnich komor ve funkci meridla Kalibrace – teplota Porovnani s etalonovym teplomerem 50 °C az 1300 °C CMC 2,8 °C 10-04","search_en":"Thermal chamber control systems in the function of a measuring instrument Calibration – temperature Comparison with a reference thermometer 50 °C to 1300 °C CMC 2,8 °C 10-04","search_zh":"作为测量器具使用的温箱控制系统 校准 – 温度 与标准温度计比较 50 °C 至 1300 °C CMC 2,8 °C 10-04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"28ab2f8baed07b33bdc0e087","lab_id":"6acfffddff06824761705e04","country":"CZ","accr_number":"2258","accr_body":"ČIA","row_label":"3","test_object":"Jednostki pomiarowe (odczytowe) termopar","test_object_en":"Thermocouple control units","test_object_zh":"热电偶显示单元","test_object_cs":"Vyhodnocovací jednotky termočlánků","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"termopary ze stopów platyny","range":"od 0 °C do 350 °C","cmc":"0,6 °C"},{"name":"termopary ze stopów platyny","range":"od 350 °C do 1700 °C","cmc":"0,5 °C"},{"name":"termopary z metali nieszlachetnych","range":"od 0 °C do 1300 °C","cmc":"0,01 % + 0,3 °C"}],"parameters_en":[{"name":"platinum alloy thermocouples","range":"0 °C to 350 °C","cmc":"0,6 °C"},{"name":"platinum alloy thermocouples","range":"350 °C to 1700 °C","cmc":"0,5 °C"},{"name":"thermocouples made of base metals","range":"0 °C to 1300 °C","cmc":"0,01 % + 0,3 °C"}],"parameters_zh":[{"name":"铂合金热电偶","range":"0 °C 至 350 °C","cmc":"0,6 °C"},{"name":"铂合金热电偶","range":"350 °C 至 1700 °C","cmc":"0,5 °C"},{"name":"贱金属热电偶","range":"0 °C 至 1300 °C","cmc":"0,01 % + 0,3 °C"}],"parameters_cs":[{"name":"termočlánky z platinových slitin","range":"0 °C až 350 °C","cmc":"0,6 °C"},{"name":"termočlánky z platinových slitin","range":"350 °C až 1700 °C","cmc":"0,5 °C"},{"name":"termočlánky z obecných kovů","range":"0 °C až 1300 °C","cmc":"0,01 % + 0,3 °C"}],"technique":"Symulacja kalibratorem napięcia","technique_en":"Voltage calibrator simulation","technique_zh":"用电压校准器模拟","technique_cs":"Simulace kalibrátorem napětí","techniques":["Symulacja kalibratorem napięcia"],"techniques_en":["Voltage calibrator simulation"],"techniques_zh":["用电压校准器模拟"],"techniques_cs":["Simulace kalibrátorem napětí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\ntermopary ze stopów platyny od 0 °C do 350 °C CMC 0,6 °C\ntermopary ze stopów platyny od 350 °C do 1700 °C CMC 0,5 °C\ntermopary z metali nieszlachetnych od 0 °C do 1300 °C CMC 0,01 % + 0,3 °C\nSymulacja kalibratorem napięcia","reference":"10-03","norm_bases":["10-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Jednostki pomiarowe (odczytowe) termopar Wzorcowanie – temperatura Symulacja kalibratorem napięcia termopary ze stopów platyny od 0 °C do 350 °C CMC 0,6 °C termopary ze stopów platyny od 350 °C do 1700 °C CMC 0,5 °C termopary z metali nieszlachetnych od 0 °C do 1300 °C CMC 0,01 % + 0,3 °C Vyhodnocovací jednotky termočlánků Kalibrace – teplota Simulace kalibrátorem napětí termočlánky z platinových slitin 0 °C až 350 °C CMC 0,6 °C termočlánky z platinových slitin 350 °C až 1700 °C CMC 0,5 °C termočlánky z obecných kovů 0 °C až 1300 °C CMC 0,01 % + 0,3 °C 10-03 Jednostki pomiarowe (odczytowe) termopar Wzorcowanie – temperatura Symulacja kalibratorem napiecia termopary ze stopow platyny od 0 °C do 350 °C CMC 0,6 °C termopary ze stopow platyny od 350 °C do 1700 °C CMC 0,5 °C termopary z metali nieszlachetnych od 0 °C do 1300 °C CMC 0,01 % + 0,3 °C Vyhodnocovaci jednotky termoclanku Kalibrace – teplota Simulace kalibratorem napeti termoclanky z platinovych slitin 0 °C az 350 °C CMC 0,6 °C termoclanky z platinovych slitin 350 °C az 1700 °C CMC 0,5 °C termoclanky z obecnych kovu 0 °C az 1300 °C CMC 0,01 % + 0,3 °C 10-03","search_en":"Thermocouple control units Calibration – temperature Voltage calibrator simulation platinum alloy thermocouples 0 °C to 350 °C CMC 0,6 °C platinum alloy thermocouples 350 °C to 1700 °C CMC 0,5 °C thermocouples made of base metals 0 °C to 1300 °C CMC 0,01 % + 0,3 °C 10-03","search_zh":"热电偶显示单元 校准 – 温度 用电压校准器模拟 铂合金热电偶 0 °C 至 350 °C CMC 0,6 °C 铂合金热电偶 350 °C 至 1700 °C CMC 0,5 °C 贱金属热电偶 0 °C 至 1300 °C CMC 0,01 % + 0,3 °C 10-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7b300f31a1bad95f287c0c9d","lab_id":"6acfffddff06824761705e04","country":"CZ","accr_number":"2258","accr_body":"ČIA","row_label":"1","test_object":"Jednostki pomiarowe (odczytowe) do sond tlenowych","test_object_en":"Control units for oxygen probes","test_object_zh":"氧探头显示单元","test_object_cs":"Vyhodnocovací jednotky pro kyslíkové sondy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"0,006 % +3 µV"},{"name":"","range":"od 100 mV do 1V","cmc":"0,006 % +10 µV"},{"name":"","range":"od 1V do 10 V","cmc":"0,009 % +100 µV"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"0,006 % +3 µV"},{"name":"","range":"100 mV to 1V","cmc":"0,006 % +10 µV"},{"name":"","range":"1V to 10 V","cmc":"0,009 % +100 µV"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"0,006 % +3 µV"},{"name":"","range":"100 mV 至 1V","cmc":"0,006 % +10 µV"},{"name":"","range":"1V 至 10 V","cmc":"0,009 % +100 µV"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"0,006 % +3 µV"},{"name":"","range":"100 mV až 1V","cmc":"0,006 % +10 µV"},{"name":"","range":"1V až 10 V","cmc":"0,009 % +100 µV"}],"technique":"Symulacja kalibratorem napięcia","technique_en":"Voltage calibrator simulation","technique_zh":"用电压校准器模拟","technique_cs":"Simulace kalibrátorem napětí","techniques":["Symulacja kalibratorem napięcia"],"techniques_en":["Voltage calibrator simulation"],"techniques_zh":["用电压校准器模拟"],"techniques_cs":["Simulace kalibrátorem napětí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 0,006 % +3 µV\nod 100 mV do 1V CMC 0,006 % +10 µV\nod 1V do 10 V CMC 0,009 % +100 µV\nSymulacja kalibratorem napięcia","reference":"10-03","norm_bases":["10-03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Jednostki pomiarowe (odczytowe) do sond tlenowych Wzorcowanie – wielkości elektryczne Symulacja kalibratorem napięcia od 0 mV do 100 mV CMC 0,006 % +3 µV od 100 mV do 1V CMC 0,006 % +10 µV od 1V do 10 V CMC 0,009 % +100 µV Vyhodnocovací jednotky pro kyslíkové sondy Kalibrace – elektrické veličiny Simulace kalibrátorem napětí 0 mV až 100 mV CMC 0,006 % +3 µV 100 mV až 1V CMC 0,006 % +10 µV 1V až 10 V CMC 0,009 % +100 µV 10-03 Jednostki pomiarowe (odczytowe) do sond tlenowych Wzorcowanie – wielkosci elektryczne Symulacja kalibratorem napiecia od 0 mV do 100 mV CMC 0,006 % +3 µV od 100 mV do 1V CMC 0,006 % +10 µV od 1V do 10 V CMC 0,009 % +100 µV Vyhodnocovaci jednotky pro kyslikove sondy Kalibrace – elektricke veliciny Simulace kalibratorem napeti 0 mV az 100 mV CMC 0,006 % +3 µV 100 mV az 1V CMC 0,006 % +10 µV 1V az 10 V CMC 0,009 % +100 µV 10-03","search_en":"Control units for oxygen probes Calibration – electrical quantities Voltage calibrator simulation 0 mV to 100 mV CMC 0,006 % +3 µV 100 mV to 1V CMC 0,006 % +10 µV 1V to 10 V CMC 0,009 % +100 µV 10-03","search_zh":"氧探头显示单元 校准 – 电学量 用电压校准器模拟 0 mV 至 100 mV CMC 0,006 % +3 µV 100 mV 至 1V CMC 0,006 % +10 µV 1V 至 10 V CMC 0,009 % +100 µV 10-03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82721aad9cc66f60ca9446c0","lab_id":"6acfffddff06824761705e04","country":"CZ","accr_number":"2258","accr_body":"ČIA","row_label":"1","test_object":"Potencjał nawęglania sondy tlenowej ZrO2","test_object_en":"Carburising potential of a ZrO2 oxygen probe","test_object_zh":"ZrO2 氧探头的渗碳势","test_object_cs":"Nauhličující potenciál kyslíkové sondy ZrO2","methodology":"Wzorcowanie – wielkości fizykochemiczne","methodology_en":"Calibration – physicochemical quantities","methodology_zh":"校准 – 物理化学量","methodology_cs":"Kalibrace – fyzikálně chemické veličiny","parameters":[{"name":"","range":"od 0%C do 1,6 % C","cmc":"0,019 % C"}],"parameters_en":[{"name":"","range":"0%C to 1,6 % C","cmc":"0,019 % C"}],"parameters_zh":[{"name":"","range":"0%C 至 1,6 % C","cmc":"0,019 % C"}],"parameters_cs":[{"name":"","range":"0%C až 1,6 % C","cmc":"0,019 % C"}],"technique":"Porównanie z sondą wzorcową w piecu wzorcującym","technique_en":"Comparison with a reference probe in a calibrating oven","technique_zh":"在校准炉中与标准探头比较","technique_cs":"Porovnání s etalonovou sondou v kalibrační pícce","techniques":["Porównanie z sondą wzorcową w piecu wzorcującym"],"techniques_en":["Comparison with a reference probe in a calibrating oven"],"techniques_zh":["在校准炉中与标准探头比较"],"techniques_cs":["Porovnání s etalonovou sondou v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizykochemiczne\nod 0%C do 1,6 % C CMC 0,019 % C\nPorównanie z sondą wzorcową w piecu wzorcującym","reference":"10-02","norm_bases":["10-02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizykochemiczne","regulatory_area_en":"CMC for the field of measured quantity: Physicochemical quantities","regulatory_area_zh":"被测量领域的CMC：物理化学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Fyzikálně chemické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Potencjał nawęglania sondy tlenowej ZrO2 Wzorcowanie – wielkości fizykochemiczne Porównanie z sondą wzorcową w piecu wzorcującym od 0%C do 1,6 % C CMC 0,019 % C Nauhličující potenciál kyslíkové sondy ZrO2 Kalibrace – fyzikálně chemické veličiny Porovnání s etalonovou sondou v kalibrační pícce 0%C až 1,6 % C CMC 0,019 % C 10-02 Potencjal naweglania sondy tlenowej ZrO2 Wzorcowanie – wielkosci fizykochemiczne Porownanie z sonda wzorcowa w piecu wzorcujacym od 0%C do 1,6 % C CMC 0,019 % C Nauhlicujici potencial kyslikove sondy ZrO2 Kalibrace – fyzikalne chemicke veliciny Porovnani s etalonovou sondou v kalibracni picce 0%C az 1,6 % C CMC 0,019 % C 10-02","search_en":"Carburising potential of a ZrO2 oxygen probe Calibration – physicochemical quantities Comparison with a reference probe in a calibrating oven 0%C to 1,6 % C CMC 0,019 % C 10-02","search_zh":"ZrO2 氧探头的渗碳势 校准 – 物理化学量 在校准炉中与标准探头比较 0%C 至 1,6 % C CMC 0,019 % C 10-02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}