{"lab":{"_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","address":"Starozuberská 1453, 756 54 Zubří","categories":["metrology"],"city":"Zubří","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[18.0949971,49.4750905]},"map_coord":[49.4750905,18.0949971],"map_geo":"cai-mapa","methods_count":70,"name":"MEROS, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: długość, prędkość obrotowa, ciśnienie, temperatura, wilgotność powietrza, wielkości elektryczne, wielkości optyczne, czas i częstotliwość.","search_text":"meros, spol. s r.o. starozuberská 1453, 756 54 zubří 2249","source_page_url":"https://www.cai.cz/?subjekt=2249-meros-spol-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"08-07-2029","website":"www.meros.cz","certificate_date":"08.07.2024","certificate_no":"325/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: długość, prędkość obrotowa, ciśnienie, temperatura, wilgotność powietrza, wielkości elektryczne, wielkości optyczne, czas i częstotliwość.","en":"Calibration in the fields of length, speed, pressure, temperature, air humidity, electrical quantities, optical quantities, time and frequency.","zh":"长度、转速、压力、温度、空气湿度、电学量、光学量、时间和频率领域的校准。","cs":"Kalibrace v oborech délka, otáčky, tlak, teplota, vlhkost vzduchu, elektrické veličiny, optické veličiny, čas a frekvence."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące MEROS","lab_division_cs":"Kalibrační laboratoř MEROS","lab_division_en":"MEROS Calibration Laboratory","lab_division_zh":"MEROS 校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"L","pl":"długość w metrach","en":"length in metres","zh":"长度，单位米","cs":"délka v metrech"},{"abbr":"R","pl":"rezystancja w MΩ","en":"resistance in MΩ","zh":"电阻，单位 MΩ","cs":"odpor v MΩ"},{"abbr":"C","pl":"pojemność w µF","en":"capacitance in µF","zh":"电容，单位 µF","cs":"kapacita v µF"},{"abbr":"L","pl":"indukcyjność w H","en":"inductance in H","zh":"电感，单位 H","cs":"indukčnost v H"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"e7adc30335d0f523c3322834db2edcbe3067f85b0583f6b5940af89a59213530","source_pdf_url":"https://www.cai.cz/OA/pdf/P325_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P325_2024_EN.pdf"},"methods":[{"_id":"13941b7c21c02c3220a888fe","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Płytki wzorcowe","test_object_en":"Parallel gauge blocks","test_object_zh":"量块","test_object_cs":"Koncové měrky","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 100 mm","cmc":"(1 L + 0,1) µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"(1 L + 0,1) µm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 100 mm","cmc":"(1 L + 0,1) µm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 100 mm","cmc":"(1 L + 0,1) µm"}],"technique":"Porównanie mechaniczne z wzorcem za pomocą komparatora","technique_en":"Mechanical comparison with a standard using a comparator","technique_zh":"用比较仪与标准器进行机械比较","technique_cs":"Mechanické porovnání s etalonem pomocí komparačního přístroje","techniques":["Porównanie mechaniczne z wzorcem za pomocą komparatora"],"techniques_en":["Mechanical comparison with a standard using a comparator"],"techniques_zh":["用比较仪与标准器进行机械比较"],"techniques_cs":["Mechanické porovnání s etalonem pomocí komparačního přístroje"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 100 mm CMC (1 L + 0,1) µm\nPorównanie mechaniczne z wzorcem za pomocą komparatora","reference":"MKGD KM.2","norm_bases":["MKGD KM.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Płytki wzorcowe Wzorcowanie – długość Porównanie mechaniczne z wzorcem za pomocą komparatora od 0,5 mm do 100 mm CMC (1 L + 0,1) µm Koncové měrky Kalibrace – délka Mechanické porovnání s etalonem pomocí komparačního přístroje 0,5 mm až 100 mm CMC (1 L + 0,1) µm MKGD KM.2 Plytki wzorcowe Wzorcowanie – dlugosc Porownanie mechaniczne z wzorcem za pomoca komparatora od 0,5 mm do 100 mm CMC (1 L + 0,1) µm Koncove merky Kalibrace – delka Mechanicke porovnani s etalonem pomoci komparacniho pristroje 0,5 mm az 100 mm CMC (1 L + 0,1) µm MKGD KM.2","search_en":"Parallel gauge blocks Calibration – length Mechanical comparison with a standard using a comparator 0,5 mm to 100 mm CMC (1 L + 0,1) µm MKGD KM.2","search_zh":"量块 校准 – 长度 用比较仪与标准器进行机械比较 0,5 mm 至 100 mm CMC (1 L + 0,1) µm MKGD KM.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"33ccd797848c15fc11f2cb1b","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"2","test_object":"Suwmiarki","test_object_en":"Slide gauges","test_object_zh":"游标卡尺","test_object_cs":"Posuvná měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 500 mm","cmc":"(8 L + 10) µm"}],"parameters_en":[{"name":"","range":"0 mm to 500 mm","cmc":"(8 L + 10) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 500 mm","cmc":"(8 L + 10) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 500 mm","cmc":"(8 L + 10) µm"}],"technique":"Porównanie z płytkami wzorcowymi i pierścieniami","technique_en":"Comparison with parallel gauge blocks and rings","technique_zh":"与量块和环规比较","technique_cs":"Porovnání s koncovými měrkami a kroužky","techniques":["Porównanie z płytkami wzorcowymi i pierścieniami"],"techniques_en":["Comparison with parallel gauge blocks and rings"],"techniques_zh":["与量块和环规比较"],"techniques_cs":["Porovnání s koncovými měrkami a kroužky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 500 mm CMC (8 L + 10) µm\nPorównanie z płytkami wzorcowymi i pierścieniami","reference":"MKGD PM.2","norm_bases":["MKGD PM.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Suwmiarki Wzorcowanie – długość Porównanie z płytkami wzorcowymi i pierścieniami od 0 mm do 500 mm CMC (8 L + 10) µm Posuvná měřidla Kalibrace – délka Porovnání s koncovými měrkami a kroužky 0 mm až 500 mm CMC (8 L + 10) µm MKGD PM.2 Suwmiarki Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi i pierscieniami od 0 mm do 500 mm CMC (8 L + 10) µm Posuvna meridla Kalibrace – delka Porovnani s koncovymi merkami a krouzky 0 mm az 500 mm CMC (8 L + 10) µm MKGD PM.2","search_en":"Slide gauges Calibration – length Comparison with parallel gauge blocks and rings 0 mm to 500 mm CMC (8 L + 10) µm MKGD PM.2","search_zh":"游标卡尺 校准 – 长度 与量块和环规比较 0 mm 至 500 mm CMC (8 L + 10) µm MKGD PM.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b8c2bfc4f60ccf570a4e73b0","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"3","test_object":"Przyrządy mikrometryczne","test_object_en":"Micrometers","test_object_zh":"测微量具","test_object_cs":"Mikrometrická měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"(1 L + 2,5) µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"(1 L + 2,5) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"(1 L + 2,5) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"(1 L + 2,5) µm"}],"technique":"Porównanie z płytkami wzorcowymi","technique_en":"Comparison with parallel gauge blocks","technique_zh":"与量块比较","technique_cs":"Porovnání s koncovými měrkami","techniques":["Porównanie z płytkami wzorcowymi"],"techniques_en":["Comparison with parallel gauge blocks"],"techniques_zh":["与量块比较"],"techniques_cs":["Porovnání s koncovými měrkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 100 mm CMC (1 L + 2,5) µm\nPorównanie z płytkami wzorcowymi","reference":"MKGD MM.2","norm_bases":["MKGD MM.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne Wzorcowanie – długość Porównanie z płytkami wzorcowymi od 0 mm do 100 mm CMC (1 L + 2,5) µm Mikrometrická měřidla Kalibrace – délka Porovnání s koncovými měrkami 0 mm až 100 mm CMC (1 L + 2,5) µm MKGD MM.2 Przyrzady mikrometryczne Wzorcowanie – dlugosc Porownanie z plytkami wzorcowymi od 0 mm do 100 mm CMC (1 L + 2,5) µm Mikrometricka meridla Kalibrace – delka Porovnani s koncovymi merkami 0 mm az 100 mm CMC (1 L + 2,5) µm MKGD MM.2","search_en":"Micrometers Calibration – length Comparison with parallel gauge blocks 0 mm to 100 mm CMC (1 L + 2,5) µm MKGD MM.2","search_zh":"测微量具 校准 – 长度 与量块比较 0 mm 至 100 mm CMC (1 L + 2,5) µm MKGD MM.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0de0253549a81d78b13e9507","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"4","test_object":"Czujniki pomiarowe","test_object_en":"Deviation meters","test_object_zh":"指示表","test_object_cs":"Úchylkoměrná měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"działka 0,01 mm","range":"od 0 mm do 30 mm","cmc":"(1 L + 2,5) µm"},{"name":"działka 0,001 mm","range":"od 0 mm do 30 mm","cmc":"(1 L + 1) µm"}],"parameters_en":[{"name":"division 0.01 mm","range":"0 mm to 30 mm","cmc":"(1 L + 2,5) µm"},{"name":"division 0.001 mm","range":"0 mm to 30 mm","cmc":"(1 L + 1) µm"}],"parameters_zh":[{"name":"分度值 0,01 mm","range":"0 mm 至 30 mm","cmc":"(1 L + 2,5) µm"},{"name":"分度值 0,001 mm","range":"0 mm 至 30 mm","cmc":"(1 L + 1) µm"}],"parameters_cs":[{"name":"dílek 0,01 mm","range":"0 mm až 30 mm","cmc":"(1 L + 2,5) µm"},{"name":"dílek 0,001 mm","range":"0 mm až 30 mm","cmc":"(1 L + 1) µm"}],"technique":"Pomiar bezpośredni na przyrządzie do wzorcowania czujników pomiarowych","technique_en":"Direct measurement on a calibration instrument for indicators","technique_zh":"在指示表校准仪上直接测量","technique_cs":"Přímé měření na přístroji pro kalibraci úchylkoměrů","techniques":["Pomiar bezpośredni na przyrządzie do wzorcowania czujników pomiarowych"],"techniques_en":["Direct measurement on a calibration instrument for indicators"],"techniques_zh":["在指示表校准仪上直接测量"],"techniques_cs":["Přímé měření na přístroji pro kalibraci úchylkoměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndziałka 0,01 mm od 0 mm do 30 mm CMC (1 L + 2,5) µm\ndziałka 0,001 mm od 0 mm do 30 mm CMC (1 L + 1) µm\nPomiar bezpośredni na przyrządzie do wzorcowania czujników pomiarowych","reference":"MKGD UM.2","norm_bases":["MKGD UM.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki pomiarowe Wzorcowanie – długość Pomiar bezpośredni na przyrządzie do wzorcowania czujników pomiarowych działka 0,01 mm od 0 mm do 30 mm CMC (1 L + 2,5) µm działka 0,001 mm od 0 mm do 30 mm CMC (1 L + 1) µm Úchylkoměrná měřidla Kalibrace – délka Přímé měření na přístroji pro kalibraci úchylkoměrů dílek 0,01 mm 0 mm až 30 mm CMC (1 L + 2,5) µm dílek 0,001 mm 0 mm až 30 mm CMC (1 L + 1) µm MKGD UM.2 Czujniki pomiarowe Wzorcowanie – dlugosc Pomiar bezposredni na przyrzadzie do wzorcowania czujnikow pomiarowych dzialka 0,01 mm od 0 mm do 30 mm CMC (1 L + 2,5) µm dzialka 0,001 mm od 0 mm do 30 mm CMC (1 L + 1) µm Uchylkomerna meridla Kalibrace – delka Prime mereni na pristroji pro kalibraci uchylkomeru dilek 0,01 mm 0 mm az 30 mm CMC (1 L + 2,5) µm dilek 0,001 mm 0 mm az 30 mm CMC (1 L + 1) µm MKGD UM.2","search_en":"Deviation meters Calibration – length Direct measurement on a calibration instrument for indicators division 0.01 mm 0 mm to 30 mm CMC (1 L + 2,5) µm division 0.001 mm 0 mm to 30 mm CMC (1 L + 1) µm MKGD UM.2","search_zh":"指示表 校准 – 长度 在指示表校准仪上直接测量 分度值 0,01 mm 0 mm 至 30 mm CMC (1 L + 2,5) µm 分度值 0,001 mm 0 mm 至 30 mm CMC (1 L + 1) µm MKGD UM.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6612501d5f47eecc2920aaee","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"5","test_object":"Sprawdziany walcowe","test_object_en":"Cylindrical gauges","test_object_zh":"圆柱塞规","test_object_cs":"Válečkové kalibry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,5 mm do 50 mm","cmc":"(1 L + 2,5) µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 50 mm","cmc":"(1 L + 2,5) µm"}],"parameters_zh":[{"name":"","range":"0,5 mm 至 50 mm","cmc":"(1 L + 2,5) µm"}],"parameters_cs":[{"name":"","range":"0,5 mm až 50 mm","cmc":"(1 L + 2,5) µm"}],"technique":"Pomiar bezpośredni pasametrem","technique_en":"Direct measurement by a passameter","technique_zh":"用杠杆卡规直接测量","technique_cs":"Přímé měření pasametrem","techniques":["Pomiar bezpośredni pasametrem"],"techniques_en":["Direct measurement by a passameter"],"techniques_zh":["用杠杆卡规直接测量"],"techniques_cs":["Přímé měření pasametrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,5 mm do 50 mm CMC (1 L + 2,5) µm\nPomiar bezpośredni pasametrem","reference":"MKGD VK.1","norm_bases":["MKGD VK.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sprawdziany walcowe Wzorcowanie – długość Pomiar bezpośredni pasametrem od 0,5 mm do 50 mm CMC (1 L + 2,5) µm Válečkové kalibry Kalibrace – délka Přímé měření pasametrem 0,5 mm až 50 mm CMC (1 L + 2,5) µm MKGD VK.1 Sprawdziany walcowe Wzorcowanie – dlugosc Pomiar bezposredni pasametrem od 0,5 mm do 50 mm CMC (1 L + 2,5) µm Valeckove kalibry Kalibrace – delka Prime mereni pasametrem 0,5 mm az 50 mm CMC (1 L + 2,5) µm MKGD VK.1","search_en":"Cylindrical gauges Calibration – length Direct measurement by a passameter 0,5 mm to 50 mm CMC (1 L + 2,5) µm MKGD VK.1","search_zh":"圆柱塞规 校准 – 长度 用杠杆卡规直接测量 0,5 mm 至 50 mm CMC (1 L + 2,5) µm MKGD VK.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb6a3e44f0f1f99f5fcd4349","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"6","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","test_object_zh":"塞尺","test_object_cs":"Spároměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0,02 mm do 2 mm","cmc":"(1 L + 2,5) µm"}],"parameters_en":[{"name":"","range":"0,02 mm to 2 mm","cmc":"(1 L + 2,5) µm"}],"parameters_zh":[{"name":"","range":"0,02 mm 至 2 mm","cmc":"(1 L + 2,5) µm"}],"parameters_cs":[{"name":"","range":"0,02 mm až 2 mm","cmc":"(1 L + 2,5) µm"}],"technique":"Pomiar bezpośredni mikrometrem","technique_en":"Direct measurement by a micrometer","technique_zh":"用千分尺直接测量","technique_cs":"Přímé měření mikrometrem","techniques":["Pomiar bezpośredni mikrometrem"],"techniques_en":["Direct measurement by a micrometer"],"techniques_zh":["用千分尺直接测量"],"techniques_cs":["Přímé měření mikrometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0,02 mm do 2 mm CMC (1 L + 2,5) µm\nPomiar bezpośredni mikrometrem","reference":"MKGD LS.1","norm_bases":["MKGD LS.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Szczelinomierze Wzorcowanie – długość Pomiar bezpośredni mikrometrem od 0,02 mm do 2 mm CMC (1 L + 2,5) µm Spároměry Kalibrace – délka Přímé měření mikrometrem 0,02 mm až 2 mm CMC (1 L + 2,5) µm MKGD LS.1 Szczelinomierze Wzorcowanie – dlugosc Pomiar bezposredni mikrometrem od 0,02 mm do 2 mm CMC (1 L + 2,5) µm Sparomery Kalibrace – delka Prime mereni mikrometrem 0,02 mm az 2 mm CMC (1 L + 2,5) µm MKGD LS.1","search_en":"Feeler gauges Calibration – length Direct measurement by a micrometer 0,02 mm to 2 mm CMC (1 L + 2,5) µm MKGD LS.1","search_zh":"塞尺 校准 – 长度 用千分尺直接测量 0,02 mm 至 2 mm CMC (1 L + 2,5) µm MKGD LS.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15f3014188d54e48306c64e1","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"7","test_object":"Stalowe taśmy miernicze zwijane","test_object_en":"Steel tape measures","test_object_zh":"钢卷尺","test_object_cs":"Ocelové svinovací metry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 3000 mm","cmc":"(20 L + 100) µm"},{"name":"","range":"od 3000 mm do 5000 mm","cmc":"(50 L + 200) µm"}],"parameters_en":[{"name":"","range":"0 mm to 3000 mm","cmc":"(20 L + 100) µm"},{"name":"","range":"3000 mm to 5000 mm","cmc":"(50 L + 200) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 3000 mm","cmc":"(20 L + 100) µm"},{"name":"","range":"3000 mm 至 5000 mm","cmc":"(50 L + 200) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 3000 mm","cmc":"(20 L + 100) µm"},{"name":"","range":"3000 mm až 5000 mm","cmc":"(50 L + 200) µm"}],"technique":"Porównywanie z liniałem stalowym","technique_en":"Comparison with a steel rule","technique_zh":"与钢直尺比较","technique_cs":"Porovnávání s ocelovým pravítkem","techniques":["Porównywanie z liniałem stalowym"],"techniques_en":["Comparison with a steel rule"],"techniques_zh":["与钢直尺比较"],"techniques_cs":["Porovnávání s ocelovým pravítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 3000 mm CMC (20 L + 100) µm\nod 3000 mm do 5000 mm CMC (50 L + 200) µm\nPorównywanie z liniałem stalowym","reference":"MKGD SM.1","norm_bases":["MKGD SM.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stalowe taśmy miernicze zwijane Wzorcowanie – długość Porównywanie z liniałem stalowym od 0 mm do 3000 mm CMC (20 L + 100) µm od 3000 mm do 5000 mm CMC (50 L + 200) µm Ocelové svinovací metry Kalibrace – délka Porovnávání s ocelovým pravítkem 0 mm až 3000 mm CMC (20 L + 100) µm 3000 mm až 5000 mm CMC (50 L + 200) µm MKGD SM.1 Stalowe tasmy miernicze zwijane Wzorcowanie – dlugosc Porownywanie z linialem stalowym od 0 mm do 3000 mm CMC (20 L + 100) µm od 3000 mm do 5000 mm CMC (50 L + 200) µm Ocelove svinovaci metry Kalibrace – delka Porovnavani s ocelovym pravitkem 0 mm az 3000 mm CMC (20 L + 100) µm 3000 mm az 5000 mm CMC (50 L + 200) µm MKGD SM.1","search_en":"Steel tape measures Calibration – length Comparison with a steel rule 0 mm to 3000 mm CMC (20 L + 100) µm 3000 mm to 5000 mm CMC (50 L + 200) µm MKGD SM.1","search_zh":"钢卷尺 校准 – 长度 与钢直尺比较 0 mm 至 3000 mm CMC (20 L + 100) µm 3000 mm 至 5000 mm CMC (50 L + 200) µm MKGD SM.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ffd856e0697760925f388e08","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"7","test_object":"Przymiary stalowe","test_object_en":"Steel rules","test_object_zh":"钢直尺","test_object_cs":"Ocelová měřítka","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 1000 mm","cmc":"(20 L + 100) µm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"(20 L + 100) µm"}],"parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"(20 L + 100) µm"}],"parameters_cs":[{"name":"","range":"0 mm až 1000 mm","cmc":"(20 L + 100) µm"}],"technique":"Porównywanie z liniałem stalowym","technique_en":"Comparison with a steel rule","technique_zh":"与钢直尺比较","technique_cs":"Porovnávání s ocelovým pravítkem","techniques":["Porównywanie z liniałem stalowym"],"techniques_en":["Comparison with a steel rule"],"techniques_zh":["与钢直尺比较"],"techniques_cs":["Porovnávání s ocelovým pravítkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 1000 mm CMC (20 L + 100) µm\nPorównywanie z liniałem stalowym","reference":"MKGD SM.1","norm_bases":["MKGD SM.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przymiary stalowe Wzorcowanie – długość Porównywanie z liniałem stalowym od 0 mm do 1000 mm CMC (20 L + 100) µm Ocelová měřítka Kalibrace – délka Porovnávání s ocelovým pravítkem 0 mm až 1000 mm CMC (20 L + 100) µm MKGD SM.1 Przymiary stalowe Wzorcowanie – dlugosc Porownywanie z linialem stalowym od 0 mm do 1000 mm CMC (20 L + 100) µm Ocelova meritka Kalibrace – delka Porovnavani s ocelovym pravitkem 0 mm az 1000 mm CMC (20 L + 100) µm MKGD SM.1","search_en":"Steel rules Calibration – length Comparison with a steel rule 0 mm to 1000 mm CMC (20 L + 100) µm MKGD SM.1","search_zh":"钢直尺 校准 – 长度 与钢直尺比较 0 mm 至 1000 mm CMC (20 L + 100) µm MKGD SM.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"33a28a333498511267aff3c8","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"8","test_object":"Taśmy miernicze","test_object_en":"Tape measures","test_object_zh":"测量卷尺","test_object_cs":"Měřická pásma","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 5000 mm","cmc":"0,4 mm"},{"name":"","range":"od 5000 mm do 20000 mm","cmc":"0,6 mm"},{"name":"","range":"od 20000 mm do 30000 mm","cmc":"0,8 mm"}],"parameters_en":[{"name":"","range":"0 mm to 5000 mm","cmc":"0,4 mm"},{"name":"","range":"5000 mm to 20000 mm","cmc":"0,6 mm"},{"name":"","range":"20000 mm to 30000 mm","cmc":"0,8 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 5000 mm","cmc":"0,4 mm"},{"name":"","range":"5000 mm 至 20000 mm","cmc":"0,6 mm"},{"name":"","range":"20000 mm 至 30000 mm","cmc":"0,8 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 5000 mm","cmc":"0,4 mm"},{"name":"","range":"5000 mm až 20000 mm","cmc":"0,6 mm"},{"name":"","range":"20000 mm až 30000 mm","cmc":"0,8 mm"}],"technique":"Porównywanie z taśmą mierniczą","technique_en":"Comparison with a tape measure","technique_zh":"与测量卷尺比较","technique_cs":"Porovnávání s měřickým pásmem","techniques":["Porównywanie z taśmą mierniczą"],"techniques_en":["Comparison with a tape measure"],"techniques_zh":["与测量卷尺比较"],"techniques_cs":["Porovnávání s měřickým pásmem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 5000 mm CMC 0,4 mm\nod 5000 mm do 20000 mm CMC 0,6 mm\nod 20000 mm do 30000 mm CMC 0,8 mm\nPorównywanie z taśmą mierniczą","reference":"MKGD SM.1","norm_bases":["MKGD SM.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Taśmy miernicze Wzorcowanie – długość Porównywanie z taśmą mierniczą od 0 mm do 5000 mm CMC 0,4 mm od 5000 mm do 20000 mm CMC 0,6 mm od 20000 mm do 30000 mm CMC 0,8 mm Měřická pásma Kalibrace – délka Porovnávání s měřickým pásmem 0 mm až 5000 mm CMC 0,4 mm 5000 mm až 20000 mm CMC 0,6 mm 20000 mm až 30000 mm CMC 0,8 mm MKGD SM.1 Tasmy miernicze Wzorcowanie – dlugosc Porownywanie z tasma miernicza od 0 mm do 5000 mm CMC 0,4 mm od 5000 mm do 20000 mm CMC 0,6 mm od 20000 mm do 30000 mm CMC 0,8 mm Mericka pasma Kalibrace – delka Porovnavani s merickym pasmem 0 mm az 5000 mm CMC 0,4 mm 5000 mm az 20000 mm CMC 0,6 mm 20000 mm az 30000 mm CMC 0,8 mm MKGD SM.1","search_en":"Tape measures Calibration – length Comparison with a tape measure 0 mm to 5000 mm CMC 0,4 mm 5000 mm to 20000 mm CMC 0,6 mm 20000 mm to 30000 mm CMC 0,8 mm MKGD SM.1","search_zh":"测量卷尺 校准 – 长度 与测量卷尺比较 0 mm 至 5000 mm CMC 0,4 mm 5000 mm 至 20000 mm CMC 0,6 mm 20000 mm 至 30000 mm CMC 0,8 mm MKGD SM.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8abd11cf8a205b7828e39046","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy","test_object_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes","test_object_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪","test_object_cs":"Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy","methodology":"Wzorcowanie – prędkość obrotowa","methodology_en":"Calibration – rotational speed","methodology_zh":"校准 – 转速","methodology_cs":"Kalibrace – otáčky","parameters":[{"name":"","range":"od 1 min⁻¹ do 100 000 min⁻¹","cmc":"1,0·10⁻⁶"}],"parameters_en":[{"name":"","range":"1 min⁻¹ to 100 000 min⁻¹","cmc":"1,0·10⁻⁶"}],"parameters_zh":[{"name":"","range":"1 min⁻¹ 至 100 000 min⁻¹","cmc":"1,0·10⁻⁶"}],"parameters_cs":[{"name":"","range":"1 min⁻¹ až 100 000 min⁻¹","cmc":"1,0·10⁻⁶"}],"technique":"Symulacja napięciem przemiennym","technique_en":"Simulation by AC voltage","technique_zh":"用交流电压模拟","technique_cs":"Simulace střídavým napětím","techniques":["Symulacja napięciem przemiennym"],"techniques_en":["Simulation by AC voltage"],"techniques_zh":["用交流电压模拟"],"techniques_cs":["Simulace střídavým napětím"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – prędkość obrotowa\nod 1 min⁻¹ do 100 000 min⁻¹ CMC 1,0·10⁻⁶\nSymulacja napięciem przemiennym","reference":"MKF-O1","norm_bases":["MKF-O1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: prędkość obrotowa","regulatory_area_en":"CMC for the field of measured quantity: Rotational speed","regulatory_area_zh":"被测量领域的CMC：转速","regulatory_area_cs":"CMC pro obor měřené veličiny: Otáčky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy Wzorcowanie – prędkość obrotowa Symulacja napięciem przemiennym od 1 min⁻¹ do 100 000 min⁻¹ CMC 1,0·10⁻⁶ Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy Kalibrace – otáčky Simulace střídavým napětím 1 min⁻¹ až 100 000 min⁻¹ CMC 1,0·10⁻⁶ MKF-O1 Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki predkosci obrotowej, stroboskopy Wzorcowanie – predkosc obrotowa Symulacja napieciem przemiennym od 1 min⁻¹ do 100 000 min⁻¹ CMC 1,0·10⁻⁶ Analogove, digitalni a bezdotykove otackomery, indukcni otackomery, snimace otacek, stroboskopy Kalibrace – otacky Simulace stridavym napetim 1 min⁻¹ az 100 000 min⁻¹ CMC 1,0·10⁻⁶ MKF-O1","search_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes Calibration – rotational speed Simulation by AC voltage 1 min⁻¹ to 100 000 min⁻¹ CMC 1,0·10⁻⁶ MKF-O1","search_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪 校准 – 转速 用交流电压模拟 1 min⁻¹ 至 100 000 min⁻¹ CMC 1,0·10⁻⁶ MKF-O1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26bf50872aba6069a3bccf41","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy","test_object_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes","test_object_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪","test_object_cs":"Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy","methodology":"Wzorcowanie – prędkość obrotowa","methodology_en":"Calibration – rotational speed","methodology_zh":"校准 – 转速","methodology_cs":"Kalibrace – otáčky","parameters":[{"name":"","range":"od 1 min⁻¹ do 60 min⁻¹","cmc":"0,00020 min⁻¹"},{"name":"","range":"od 60 min⁻¹ do 100 000 min⁻¹","cmc":"1,5·10⁻⁶"}],"parameters_en":[{"name":"","range":"1 min⁻¹ to 60 min⁻¹","cmc":"0,00020 min⁻¹"},{"name":"","range":"60 min⁻¹ to 100 000 min⁻¹","cmc":"1,5·10⁻⁶"}],"parameters_zh":[{"name":"","range":"1 min⁻¹ 至 60 min⁻¹","cmc":"0,00020 min⁻¹"},{"name":"","range":"60 min⁻¹ 至 100 000 min⁻¹","cmc":"1,5·10⁻⁶"}],"parameters_cs":[{"name":"","range":"1 min⁻¹ až 60 min⁻¹","cmc":"0,00020 min⁻¹"},{"name":"","range":"60 min⁻¹ až 100 000 min⁻¹","cmc":"1,5·10⁻⁶"}],"technique":"Symulacja przetwornikiem optycznym","technique_en":"Simulation by an optical transducer","technique_zh":"用光学变送器模拟","technique_cs":"Simulace optickým převodníkem","techniques":["Symulacja przetwornikiem optycznym"],"techniques_en":["Simulation by an optical transducer"],"techniques_zh":["用光学变送器模拟"],"techniques_cs":["Simulace optickým převodníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – prędkość obrotowa\nZakres:\nod 1 min⁻¹ do 60 min⁻¹ CMC 0,00020 min⁻¹\nod 60 min⁻¹ do 100 000 min⁻¹ CMC 1,5·10⁻⁶\nSymulacja przetwornikiem optycznym","reference":"MKF-O1","norm_bases":["MKF-O1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: prędkość obrotowa","regulatory_area_en":"CMC for the field of measured quantity: Rotational speed","regulatory_area_zh":"被测量领域的CMC：转速","regulatory_area_cs":"CMC pro obor měřené veličiny: Otáčky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy Wzorcowanie – prędkość obrotowa Symulacja przetwornikiem optycznym od 1 min⁻¹ do 60 min⁻¹ CMC 0,00020 min⁻¹ od 60 min⁻¹ do 100 000 min⁻¹ CMC 1,5·10⁻⁶ Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy Kalibrace – otáčky Simulace optickým převodníkem 1 min⁻¹ až 60 min⁻¹ CMC 0,00020 min⁻¹ 60 min⁻¹ až 100 000 min⁻¹ CMC 1,5·10⁻⁶ MKF-O1 Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki predkosci obrotowej, stroboskopy Wzorcowanie – predkosc obrotowa Symulacja przetwornikiem optycznym od 1 min⁻¹ do 60 min⁻¹ CMC 0,00020 min⁻¹ od 60 min⁻¹ do 100 000 min⁻¹ CMC 1,5·10⁻⁶ Analogove, digitalni a bezdotykove otackomery, indukcni otackomery, snimace otacek, stroboskopy Kalibrace – otacky Simulace optickym prevodnikem 1 min⁻¹ az 60 min⁻¹ CMC 0,00020 min⁻¹ 60 min⁻¹ az 100 000 min⁻¹ CMC 1,5·10⁻⁶ MKF-O1","search_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes Calibration – rotational speed Simulation by an optical transducer 1 min⁻¹ to 60 min⁻¹ CMC 0,00020 min⁻¹ 60 min⁻¹ to 100 000 min⁻¹ CMC 1,5·10⁻⁶ MKF-O1","search_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪 校准 – 转速 用光学变送器模拟 1 min⁻¹ 至 60 min⁻¹ CMC 0,00020 min⁻¹ 60 min⁻¹ 至 100 000 min⁻¹ CMC 1,5·10⁻⁶ MKF-O1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08089222afa3ee2d3dbb4726","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy","test_object_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes","test_object_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪","test_object_cs":"Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy","methodology":"Wzorcowanie – prędkość obrotowa","methodology_en":"Calibration – rotational speed","methodology_zh":"校准 – 转速","methodology_cs":"Kalibrace – otáčky","parameters":[{"name":"","range":"od 1 min⁻¹ do 5 min⁻¹","cmc":"0,25 %"},{"name":"","range":"od 5 min⁻¹ do 20 min⁻¹","cmc":"0,070 %"},{"name":"","range":"od 20 min⁻¹ do 10 000 min⁻¹","cmc":"0,0060 %"}],"parameters_en":[{"name":"","range":"1 min⁻¹ to 5 min⁻¹","cmc":"0,25 %"},{"name":"","range":"5 min⁻¹ to 20 min⁻¹","cmc":"0,070 %"},{"name":"","range":"20 min⁻¹ to 10 000 min⁻¹","cmc":"0,0060 %"}],"parameters_zh":[{"name":"","range":"1 min⁻¹ 至 5 min⁻¹","cmc":"0,25 %"},{"name":"","range":"5 min⁻¹ 至 20 min⁻¹","cmc":"0,070 %"},{"name":"","range":"20 min⁻¹ 至 10 000 min⁻¹","cmc":"0,0060 %"}],"parameters_cs":[{"name":"","range":"1 min⁻¹ až 5 min⁻¹","cmc":"0,25 %"},{"name":"","range":"5 min⁻¹ až 20 min⁻¹","cmc":"0,070 %"},{"name":"","range":"20 min⁻¹ až 10 000 min⁻¹","cmc":"0,0060 %"}],"technique":"Bezpośrednie generowanie wzorcem prędkości obrotowej, metoda stykowa i bezstykowa","technique_en":"Direct generation by a speed standard – contact and non-contact method","technique_zh":"用转速标准器直接产生，接触式和非接触式方法","technique_cs":"Přímé generování etalonem otáček, kontaktní a bezkontaktní metoda","techniques":["Bezpośrednie generowanie wzorcem prędkości obrotowej, metoda stykowa i bezstykowa"],"techniques_en":["Direct generation by a speed standard – contact and non-contact method"],"techniques_zh":["用转速标准器直接产生，接触式和非接触式方法"],"techniques_cs":["Přímé generování etalonem otáček, kontaktní a bezkontaktní metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – prędkość obrotowa\nZakres:\nod 1 min⁻¹ do 5 min⁻¹ CMC 0,25 %\nod 5 min⁻¹ do 20 min⁻¹ CMC 0,070 %\nod 20 min⁻¹ do 10 000 min⁻¹ CMC 0,0060 %\nBezpośrednie generowanie wzorcem prędkości obrotowej, metoda stykowa i bezstykowa","reference":"MKF-O1","norm_bases":["MKF-O1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: prędkość obrotowa","regulatory_area_en":"CMC for the field of measured quantity: Rotational speed","regulatory_area_zh":"被测量领域的CMC：转速","regulatory_area_cs":"CMC pro obor měřené veličiny: Otáčky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy Wzorcowanie – prędkość obrotowa Bezpośrednie generowanie wzorcem prędkości obrotowej, metoda stykowa i bezstykowa od 1 min⁻¹ do 5 min⁻¹ CMC 0,25 % od 5 min⁻¹ do 20 min⁻¹ CMC 0,070 % od 20 min⁻¹ do 10 000 min⁻¹ CMC 0,0060 % Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy Kalibrace – otáčky Přímé generování etalonem otáček, kontaktní a bezkontaktní metoda 1 min⁻¹ až 5 min⁻¹ CMC 0,25 % 5 min⁻¹ až 20 min⁻¹ CMC 0,070 % 20 min⁻¹ až 10 000 min⁻¹ CMC 0,0060 % MKF-O1 Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki predkosci obrotowej, stroboskopy Wzorcowanie – predkosc obrotowa Bezposrednie generowanie wzorcem predkosci obrotowej, metoda stykowa i bezstykowa od 1 min⁻¹ do 5 min⁻¹ CMC 0,25 % od 5 min⁻¹ do 20 min⁻¹ CMC 0,070 % od 20 min⁻¹ do 10 000 min⁻¹ CMC 0,0060 % Analogove, digitalni a bezdotykove otackomery, indukcni otackomery, snimace otacek, stroboskopy Kalibrace – otacky Prime generovani etalonem otacek, kontaktni a bezkontaktni metoda 1 min⁻¹ az 5 min⁻¹ CMC 0,25 % 5 min⁻¹ az 20 min⁻¹ CMC 0,070 % 20 min⁻¹ az 10 000 min⁻¹ CMC 0,0060 % MKF-O1","search_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes Calibration – rotational speed Direct generation by a speed standard – contact and non-contact method 1 min⁻¹ to 5 min⁻¹ CMC 0,25 % 5 min⁻¹ to 20 min⁻¹ CMC 0,070 % 20 min⁻¹ to 10 000 min⁻¹ CMC 0,0060 % MKF-O1","search_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪 校准 – 转速 用转速标准器直接产生，接触式和非接触式方法 1 min⁻¹ 至 5 min⁻¹ CMC 0,25 % 5 min⁻¹ 至 20 min⁻¹ CMC 0,070 % 20 min⁻¹ 至 10 000 min⁻¹ CMC 0,0060 % MKF-O1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d8df8ff7f84024ee4455e0c1","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy","test_object_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes","test_object_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪","test_object_cs":"Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy","methodology":"Wzorcowanie – prędkość obrotowa","methodology_en":"Calibration – rotational speed","methodology_zh":"校准 – 转速","methodology_cs":"Kalibrace – otáčky","parameters":[{"name":"czas pomiaru co najmniej 4 min","range":"od 1 min⁻¹ do 60 min⁻¹","cmc":"0,11 %"}],"parameters_en":[{"name":"measurement time at least 4 min","range":"1 min⁻¹ to 60 min⁻¹","cmc":"0,11 %"}],"parameters_zh":[{"name":"测量时间至少 4 min","range":"1 min⁻¹ 至 60 min⁻¹","cmc":"0,11 %"}],"parameters_cs":[{"name":"doba měření nejméně 4 min","range":"1 min⁻¹ až 60 min⁻¹","cmc":"0,11 %"}],"technique":"Porównanie ze stoperami wzorcowymi","technique_en":"Comparison with a reference stopwatch","technique_zh":"与标准秒表比较","technique_cs":"Porovnání s etalonovými stopkami","techniques":["Porównanie ze stoperami wzorcowymi"],"techniques_en":["Comparison with a reference stopwatch"],"techniques_zh":["与标准秒表比较"],"techniques_cs":["Porovnání s etalonovými stopkami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – prędkość obrotowa\nczas pomiaru co najmniej 4 min od 1 min⁻¹ do 60 min⁻¹ CMC 0,11 %\nPorównanie ze stoperami wzorcowymi","reference":"MKF-O1","norm_bases":["MKF-O1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: prędkość obrotowa","regulatory_area_en":"CMC for the field of measured quantity: Rotational speed","regulatory_area_zh":"被测量领域的CMC：转速","regulatory_area_cs":"CMC pro obor měřené veličiny: Otáčky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki prędkości obrotowej, stroboskopy Wzorcowanie – prędkość obrotowa Porównanie ze stoperami wzorcowymi czas pomiaru co najmniej 4 min od 1 min⁻¹ do 60 min⁻¹ CMC 0,11 % Analogové, digitální a bezdotykové otáčkoměry, indukční otáčkoměry, snímače otáček, stroboskopy Kalibrace – otáčky Porovnání s etalonovými stopkami doba měření nejméně 4 min 1 min⁻¹ až 60 min⁻¹ CMC 0,11 % MKF-O1 Obrotomierze analogowe, cyfrowe i bezdotykowe, obrotomierze indukcyjne, czujniki predkosci obrotowej, stroboskopy Wzorcowanie – predkosc obrotowa Porownanie ze stoperami wzorcowymi czas pomiaru co najmniej 4 min od 1 min⁻¹ do 60 min⁻¹ CMC 0,11 % Analogove, digitalni a bezdotykove otackomery, indukcni otackomery, snimace otacek, stroboskopy Kalibrace – otacky Porovnani s etalonovymi stopkami doba mereni nejmene 4 min 1 min⁻¹ az 60 min⁻¹ CMC 0,11 % MKF-O1","search_en":"Analogue, digital and proximity revolution counters, induction revolution counters, rpm sensors, stroboscopes Calibration – rotational speed Comparison with a reference stopwatch measurement time at least 4 min 1 min⁻¹ to 60 min⁻¹ CMC 0,11 % MKF-O1","search_zh":"模拟、数字和非接触式转速表、感应式转速表、转速传感器、频闪仪 校准 – 转速 与标准秒表比较 测量时间至少 4 min 1 min⁻¹ 至 60 min⁻¹ CMC 0,11 % MKF-O1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"34b5c43f91638e840fb62a01","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, różnicowe tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers, differential pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器、差压测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku, diferenční měřící řetězce tlaku","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"Nadciśnienie, gaz","range":"od 0 kPa do 1 kPa","cmc":"0,1 % + 0,0015 kPa"},{"name":"Nadciśnienie, gaz","range":"od 1 kPa do 10 kPa","cmc":"0,04 % + 0,004 kPa"},{"name":"Nadciśnienie, gaz","range":"od 10 kPa do 200 kPa","cmc":"0,05 % + 0,03 kPa"},{"name":"Nadciśnienie, gaz","range":"od 200 kPa do 600 kPa","cmc":"0,06 % + 0,05 kPa"},{"name":"Nadciśnienie, gaz","range":"od 600 kPa do 2 000 kPa","cmc":"0,07 % + 0,11 kPa"},{"name":"Podciśnienie, gaz","range":"od 0 kPa do 1 kPa","cmc":"0,1 % + 1,5 Pa"},{"name":"Podciśnienie, gaz","range":"od 1 kPa do 90 kPa","cmc":"0,05 % + 13 Pa"},{"name":"Nadciśnienie, ciecz","range":"od 0 MPa do 2 MPa","cmc":"0,05 % + 0,3 kPa"},{"name":"Nadciśnienie, ciecz","range":"od 2 MPa do 10 MPa","cmc":"0,06 % + 1 kPa"},{"name":"Nadciśnienie, ciecz","range":"od 10 MPa do 25 MPa","cmc":"0,05 % + 5 kPa"},{"name":"Nadciśnienie, ciecz","range":"od 25 MPa do 60 MPa","cmc":"0,06 % + 9 kPa"},{"name":"Ciśnienie bezwzględne, gaz","range":"od 5 kPa do 2 000 kPa","cmc":"0,05 % + 0,3 kPa"},{"name":"Ciśnienie bezwzględne, ciecz","range":"od 2000 kPa do 10000 kPa","cmc":"0,07 % + 1,2 kPa"},{"name":"Ciśnienie bezwzględne, ciecz","range":"od 10000 kPa do 25000 kPa","cmc":"0,06 % + 4 kPa"},{"name":"Ciśnienie barometryczne","range":"od 500 hPa do 1100 hPa","cmc":"0,4 hPa"}],"parameters_en":[{"name":"Gauge pressure, gas","range":"0 kPa to 1 kPa","cmc":"0,1 % + 0,0015 kPa"},{"name":"Gauge pressure, gas","range":"1 kPa to 10 kPa","cmc":"0,04 % + 0,004 kPa"},{"name":"Gauge pressure, gas","range":"10 kPa to 200 kPa","cmc":"0,05 % + 0,03 kPa"},{"name":"Gauge pressure, gas","range":"200 kPa to 600 kPa","cmc":"0,06 % + 0,05 kPa"},{"name":"Gauge pressure, gas","range":"600 kPa to 2 000 kPa","cmc":"0,07 % + 0,11 kPa"},{"name":"Vacuum, gas","range":"0 kPa to 1 kPa","cmc":"0,1 % + 1,5 Pa"},{"name":"Vacuum, gas","range":"1 kPa to 90 kPa","cmc":"0,05 % + 13 Pa"},{"name":"Gauge pressure, liquid","range":"0 MPa to 2 MPa","cmc":"0,05 % + 0,3 kPa"},{"name":"Gauge pressure, liquid","range":"2 MPa to 10 MPa","cmc":"0,06 % + 1 kPa"},{"name":"Gauge pressure, liquid","range":"10 MPa to 25 MPa","cmc":"0,05 % + 5 kPa"},{"name":"Gauge pressure, liquid","range":"25 MPa to 60 MPa","cmc":"0,06 % + 9 kPa"},{"name":"Absolute pressure, gas","range":"5 kPa to 2 000 kPa","cmc":"0,05 % + 0,3 kPa"},{"name":"Absolute pressure, liquid","range":"2000 kPa to 10000 kPa","cmc":"0,07 % + 1,2 kPa"},{"name":"Absolute pressure, liquid","range":"10000 kPa to 25000 kPa","cmc":"0,06 % + 4 kPa"},{"name":"Barometric pressure","range":"500 hPa to 1100 hPa","cmc":"0,4 hPa"}],"parameters_zh":[{"name":"表压，气体","range":"0 kPa 至 1 kPa","cmc":"0,1 % + 0,0015 kPa"},{"name":"表压，气体","range":"1 kPa 至 10 kPa","cmc":"0,04 % + 0,004 kPa"},{"name":"表压，气体","range":"10 kPa 至 200 kPa","cmc":"0,05 % + 0,03 kPa"},{"name":"表压，气体","range":"200 kPa 至 600 kPa","cmc":"0,06 % + 0,05 kPa"},{"name":"表压，气体","range":"600 kPa 至 2 000 kPa","cmc":"0,07 % + 0,11 kPa"},{"name":"负压，气体","range":"0 kPa 至 1 kPa","cmc":"0,1 % + 1,5 Pa"},{"name":"负压，气体","range":"1 kPa 至 90 kPa","cmc":"0,05 % + 13 Pa"},{"name":"表压，液体","range":"0 MPa 至 2 MPa","cmc":"0,05 % + 0,3 kPa"},{"name":"表压，液体","range":"2 MPa 至 10 MPa","cmc":"0,06 % + 1 kPa"},{"name":"表压，液体","range":"10 MPa 至 25 MPa","cmc":"0,05 % + 5 kPa"},{"name":"表压，液体","range":"25 MPa 至 60 MPa","cmc":"0,06 % + 9 kPa"},{"name":"绝对压力，气体","range":"5 kPa 至 2 000 kPa","cmc":"0,05 % + 0,3 kPa"},{"name":"绝对压力，液体","range":"2000 kPa 至 10000 kPa","cmc":"0,07 % + 1,2 kPa"},{"name":"绝对压力，液体","range":"10000 kPa 至 25000 kPa","cmc":"0,06 % + 4 kPa"},{"name":"大气压力","range":"500 hPa 至 1100 hPa","cmc":"0,4 hPa"}],"parameters_cs":[{"name":"Přetlak, plyn","range":"0 kPa až 1 kPa","cmc":"0,1 % + 0,0015 kPa"},{"name":"Přetlak, plyn","range":"1 kPa až 10 kPa","cmc":"0,04 % + 0,004 kPa"},{"name":"Přetlak, plyn","range":"10 kPa až 200 kPa","cmc":"0,05 % + 0,03 kPa"},{"name":"Přetlak, plyn","range":"200 kPa až 600 kPa","cmc":"0,06 % + 0,05 kPa"},{"name":"Přetlak, plyn","range":"600 kPa až 2 000 kPa","cmc":"0,07 % + 0,11 kPa"},{"name":"Podtlak, plyn","range":"0 kPa až 1 kPa","cmc":"0,1 % + 1,5 Pa"},{"name":"Podtlak, plyn","range":"1 kPa až 90 kPa","cmc":"0,05 % + 13 Pa"},{"name":"Přetlak, kapalina","range":"0 MPa až 2 MPa","cmc":"0,05 % + 0,3 kPa"},{"name":"Přetlak, kapalina","range":"2 MPa až 10 MPa","cmc":"0,06 % + 1 kPa"},{"name":"Přetlak, kapalina","range":"10 MPa až 25 MPa","cmc":"0,05 % + 5 kPa"},{"name":"Přetlak, kapalina","range":"25 MPa až 60 MPa","cmc":"0,06 % + 9 kPa"},{"name":"Absolutní tlak, plyn","range":"5 kPa až 2 000 kPa","cmc":"0,05 % + 0,3 kPa"},{"name":"Absolutní tlak, kapalina","range":"2000 kPa až 10000 kPa","cmc":"0,07 % + 1,2 kPa"},{"name":"Absolutní tlak, kapalina","range":"10000 kPa až 25000 kPa","cmc":"0,06 % + 4 kPa"},{"name":"Barometrický tlak","range":"500 hPa až 1100 hPa","cmc":"0,4 hPa"}],"technique":"Porównanie z ciśnieniomierzem cyfrowym","technique_en":"Comparison with a digital manometer","technique_zh":"与数字压力计比较","technique_cs":"Porovnání s digitálním tlakoměrem","techniques":["Porównanie z ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a digital manometer"],"techniques_zh":["与数字压力计比较"],"techniques_cs":["Porovnání s digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nZakres:\nNadciśnienie, gaz od 0 kPa do 1 kPa CMC 0,1 % + 0,0015 kPa\nNadciśnienie, gaz od 1 kPa do 10 kPa CMC 0,04 % + 0,004 kPa\nNadciśnienie, gaz od 10 kPa do 200 kPa CMC 0,05 % + 0,03 kPa\nNadciśnienie, gaz od 200 kPa do 600 kPa CMC 0,06 % + 0,05 kPa\nNadciśnienie, gaz od 600 kPa do 2 000 kPa CMC 0,07 % + 0,11 kPa\nPodciśnienie, gaz od 0 kPa do 1 kPa CMC 0,1 % + 1,5 Pa\nPodciśnienie, gaz od 1 kPa do 90 kPa CMC 0,05 % + 13 Pa\nNadciśnienie, ciecz od 0 MPa do 2 MPa CMC 0,05 % + 0,3 kPa\nNadciśnienie, ciecz od 2 MPa do 10 MPa CMC 0,06 % + 1 kPa\nNadciśnienie, ciecz od 10 MPa do 25 MPa CMC 0,05 % + 5 kPa\nNadciśnienie, ciecz od 25 MPa do 60 MPa CMC 0,06 % + 9 kPa\nCiśnienie bezwzględne, gaz od 5 kPa do 2 000 kPa CMC 0,05 % + 0,3 kPa\nCiśnienie bezwzględne, ciecz od 2000 kPa do 10000 kPa CMC 0,07 % + 1,2 kPa\nCiśnienie bezwzględne, ciecz od 10000 kPa do 25000 kPa CMC 0,06 % + 4 kPa\nCiśnienie barometryczne od 500 hPa do 1100 hPa CMC 0,4 hPa\nPorównanie z ciśnieniomierzem cyfrowym","reference":"MKMP TL.2","norm_bases":["MKMP TL.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, różnicowe tory pomiarowe ciśnienia Wzorcowanie – ciśnienie, naprężenie mechaniczne Porównanie z ciśnieniomierzem cyfrowym Nadciśnienie, gaz od 0 kPa do 1 kPa CMC 0,1 % + 0,0015 kPa Nadciśnienie, gaz od 1 kPa do 10 kPa CMC 0,04 % + 0,004 kPa Nadciśnienie, gaz od 10 kPa do 200 kPa CMC 0,05 % + 0,03 kPa Nadciśnienie, gaz od 200 kPa do 600 kPa CMC 0,06 % + 0,05 kPa Nadciśnienie, gaz od 600 kPa do 2 000 kPa CMC 0,07 % + 0,11 kPa Podciśnienie, gaz od 0 kPa do 1 kPa CMC 0,1 % + 1,5 Pa Podciśnienie, gaz od 1 kPa do 90 kPa CMC 0,05 % + 13 Pa Nadciśnienie, ciecz od 0 MPa do 2 MPa CMC 0,05 % + 0,3 kPa Nadciśnienie, ciecz od 2 MPa do 10 MPa CMC 0,06 % + 1 kPa Nadciśnienie, ciecz od 10 MPa do 25 MPa CMC 0,05 % + 5 kPa Nadciśnienie, ciecz od 25 MPa do 60 MPa CMC 0,06 % + 9 kPa Ciśnienie bezwzględne, gaz od 5 kPa do 2 000 kPa CMC 0,05 % + 0,3 kPa Ciśnienie bezwzględne, ciecz od 2000 kPa do 10000 kPa CMC 0,07 % + 1,2 kPa Ciśnienie bezwzględne, ciecz od 10000 kPa do 25000 kPa CMC 0,06 % + 4 kPa Ciśnienie barometryczne od 500 hPa do 1100 hPa CMC 0,4 hPa Deformační a číslicové tlakoměry, převodníky tlaku, diferenční měřící řetězce tlaku Kalibrace – tlak, mechanické napětí Porovnání s digitálním tlakoměrem Přetlak, plyn 0 kPa až 1 kPa CMC 0,1 % + 0,0015 kPa Přetlak, plyn 1 kPa až 10 kPa CMC 0,04 % + 0,004 kPa Přetlak, plyn 10 kPa až 200 kPa CMC 0,05 % + 0,03 kPa Přetlak, plyn 200 kPa až 600 kPa CMC 0,06 % + 0,05 kPa Přetlak, plyn 600 kPa až 2 000 kPa CMC 0,07 % + 0,11 kPa Podtlak, plyn 0 kPa až 1 kPa CMC 0,1 % + 1,5 Pa Podtlak, plyn 1 kPa až 90 kPa CMC 0,05 % + 13 Pa Přetlak, kapalina 0 MPa až 2 MPa CMC 0,05 % + 0,3 kPa Přetlak, kapalina 2 MPa až 10 MPa CMC 0,06 % + 1 kPa Přetlak, kapalina 10 MPa až 25 MPa CMC 0,05 % + 5 kPa Přetlak, kapalina 25 MPa až 60 MPa CMC 0,06 % + 9 kPa Absolutní tlak, plyn 5 kPa až 2 000 kPa CMC 0,05 % + 0,3 kPa Absolutní tlak, kapalina 2000 kPa až 10000 kPa CMC 0,07 % + 1,2 kPa Absolutní tlak, kapalina 10000 kPa až 25000 kPa CMC 0,06 % + 4 kPa Barometrický tlak 500 hPa až 1100 hPa CMC 0,4 hPa MKMP TL.2 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia, roznicowe tory pomiarowe cisnienia Wzorcowanie – cisnienie, naprezenie mechaniczne Porownanie z cisnieniomierzem cyfrowym Nadcisnienie, gaz od 0 kPa do 1 kPa CMC 0,1 % + 0,0015 kPa Nadcisnienie, gaz od 1 kPa do 10 kPa CMC 0,04 % + 0,004 kPa Nadcisnienie, gaz od 10 kPa do 200 kPa CMC 0,05 % + 0,03 kPa Nadcisnienie, gaz od 200 kPa do 600 kPa CMC 0,06 % + 0,05 kPa Nadcisnienie, gaz od 600 kPa do 2 000 kPa CMC 0,07 % + 0,11 kPa Podcisnienie, gaz od 0 kPa do 1 kPa CMC 0,1 % + 1,5 Pa Podcisnienie, gaz od 1 kPa do 90 kPa CMC 0,05 % + 13 Pa Nadcisnienie, ciecz od 0 MPa do 2 MPa CMC 0,05 % + 0,3 kPa Nadcisnienie, ciecz od 2 MPa do 10 MPa CMC 0,06 % + 1 kPa Nadcisnienie, ciecz od 10 MPa do 25 MPa CMC 0,05 % + 5 kPa Nadcisnienie, ciecz od 25 MPa do 60 MPa CMC 0,06 % + 9 kPa Cisnienie bezwzgledne, gaz od 5 kPa do 2 000 kPa CMC 0,05 % + 0,3 kPa Cisnienie bezwzgledne, ciecz od 2000 kPa do 10000 kPa CMC 0,07 % + 1,2 kPa Cisnienie bezwzgledne, ciecz od 10000 kPa do 25000 kPa CMC 0,06 % + 4 kPa Cisnienie barometryczne od 500 hPa do 1100 hPa CMC 0,4 hPa Deformacni a cislicove tlakomery, prevodniky tlaku, diferencni merici retezce tlaku Kalibrace – tlak, mechanicke napeti Porovnani s digitalnim tlakomerem Pretlak, plyn 0 kPa az 1 kPa CMC 0,1 % + 0,0015 kPa Pretlak, plyn 1 kPa az 10 kPa CMC 0,04 % + 0,004 kPa Pretlak, plyn 10 kPa az 200 kPa CMC 0,05 % + 0,03 kPa Pretlak, plyn 200 kPa az 600 kPa CMC 0,06 % + 0,05 kPa Pretlak, plyn 600 kPa az 2 000 kPa CMC 0,07 % + 0,11 kPa Podtlak, plyn 0 kPa az 1 kPa CMC 0,1 % + 1,5 Pa Podtlak, plyn 1 kPa az 90 kPa CMC 0,05 % + 13 Pa Pretlak, kapalina 0 MPa az 2 MPa CMC 0,05 % + 0,3 kPa Pretlak, kapalina 2 MPa az 10 MPa CMC 0,06 % + 1 kPa Pretlak, kapalina 10 MPa az 25 MPa CMC 0,05 % + 5 kPa Pretlak, kapalina 25 MPa az 60 MPa CMC 0,06 % + 9 kPa Absolutni tlak, plyn 5 kPa az 2 000 kPa CMC 0,05 % + 0,3 kPa Absolutni tlak, kapalina 2000 kPa az 10000 kPa CMC 0,07 % + 1,2 kPa Absolutni tlak, kapalina 10000 kPa az 25000 kPa CMC 0,06 % + 4 kPa Barometricky tlak 500 hPa az 1100 hPa CMC 0,4 hPa MKMP TL.2","search_en":"Deformation and digital manometers, pressure transducers, differential pressure measuring chains Calibration – pressure, mechanical stress Comparison with a digital manometer Gauge pressure, gas 0 kPa to 1 kPa CMC 0,1 % + 0,0015 kPa Gauge pressure, gas 1 kPa to 10 kPa CMC 0,04 % + 0,004 kPa Gauge pressure, gas 10 kPa to 200 kPa CMC 0,05 % + 0,03 kPa Gauge pressure, gas 200 kPa to 600 kPa CMC 0,06 % + 0,05 kPa Gauge pressure, gas 600 kPa to 2 000 kPa CMC 0,07 % + 0,11 kPa Vacuum, gas 0 kPa to 1 kPa CMC 0,1 % + 1,5 Pa Vacuum, gas 1 kPa to 90 kPa CMC 0,05 % + 13 Pa Gauge pressure, liquid 0 MPa to 2 MPa CMC 0,05 % + 0,3 kPa Gauge pressure, liquid 2 MPa to 10 MPa CMC 0,06 % + 1 kPa Gauge pressure, liquid 10 MPa to 25 MPa CMC 0,05 % + 5 kPa Gauge pressure, liquid 25 MPa to 60 MPa CMC 0,06 % + 9 kPa Absolute pressure, gas 5 kPa to 2 000 kPa CMC 0,05 % + 0,3 kPa Absolute pressure, liquid 2000 kPa to 10000 kPa CMC 0,07 % + 1,2 kPa Absolute pressure, liquid 10000 kPa to 25000 kPa CMC 0,06 % + 4 kPa Barometric pressure 500 hPa to 1100 hPa CMC 0,4 hPa MKMP TL.2","search_zh":"弹性式和数字式压力表、压力变送器、差压测量链 校准 – 压力、机械应力 与数字压力计比较 表压，气体 0 kPa 至 1 kPa CMC 0,1 % + 0,0015 kPa 表压，气体 1 kPa 至 10 kPa CMC 0,04 % + 0,004 kPa 表压，气体 10 kPa 至 200 kPa CMC 0,05 % + 0,03 kPa 表压，气体 200 kPa 至 600 kPa CMC 0,06 % + 0,05 kPa 表压，气体 600 kPa 至 2 000 kPa CMC 0,07 % + 0,11 kPa 负压，气体 0 kPa 至 1 kPa CMC 0,1 % + 1,5 Pa 负压，气体 1 kPa 至 90 kPa CMC 0,05 % + 13 Pa 表压，液体 0 MPa 至 2 MPa CMC 0,05 % + 0,3 kPa 表压，液体 2 MPa 至 10 MPa CMC 0,06 % + 1 kPa 表压，液体 10 MPa 至 25 MPa CMC 0,05 % + 5 kPa 表压，液体 25 MPa 至 60 MPa CMC 0,06 % + 9 kPa 绝对压力，气体 5 kPa 至 2 000 kPa CMC 0,05 % + 0,3 kPa 绝对压力，液体 2000 kPa 至 10000 kPa CMC 0,07 % + 1,2 kPa 绝对压力，液体 10000 kPa 至 25000 kPa CMC 0,06 % + 4 kPa 大气压力 500 hPa 至 1100 hPa CMC 0,4 hPa MKMP TL.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a6834fcd339ce5753e48b3bf","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Termometry rezystancyjne","test_object_en":"Resistance thermometers","test_object_zh":"电阻温度计","test_object_cs":"Odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -30 °C","cmc":"0,12 °C"},{"name":"","range":"od -30 °C do 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"od 0 °C do 150 °C","cmc":"0,07 °C"},{"name":"","range":"od 150 °C do 260 °C","cmc":"0,08 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -30 °C","cmc":"0,12 °C"},{"name":"","range":"-30 °C to 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C to 150 °C","cmc":"0,07 °C"},{"name":"","range":"150 °C to 260 °C","cmc":"0,08 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -30 °C","cmc":"0,12 °C"},{"name":"","range":"-30 °C 至 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C 至 150 °C","cmc":"0,07 °C"},{"name":"","range":"150 °C 至 260 °C","cmc":"0,08 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -30 °C","cmc":"0,12 °C"},{"name":"","range":"-30 °C až 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C až 150 °C","cmc":"0,07 °C"},{"name":"","range":"150 °C až 260 °C","cmc":"0,08 °C"}],"technique":"Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej","technique_en":"Comparison with a resistance temperature sensor in a liquid bath","technique_zh":"在液体槽中与电阻温度传感器比较","technique_cs":"Porovnání s odporovým snímačem teploty v kapalné lázni","techniques":["Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej"],"techniques_en":["Comparison with a resistance temperature sensor in a liquid bath"],"techniques_zh":["在液体槽中与电阻温度传感器比较"],"techniques_cs":["Porovnání s odporovým snímačem teploty v kapalné lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -30 °C CMC 0,12 °C\nod -30 °C do 0 °C CMC 0,08 °C\n0 °C CMC 0,05 °C\nod 0 °C do 150 °C CMC 0,07 °C\nod 150 °C do 260 °C CMC 0,08 °C\nPorównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej","reference":"MKTT OT.2","norm_bases":["MKTT OT.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry rezystancyjne Wzorcowanie – temperatura Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej od -80 °C do -30 °C CMC 0,12 °C od -30 °C do 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C od 0 °C do 150 °C CMC 0,07 °C od 150 °C do 260 °C CMC 0,08 °C Odporové teploměry Kalibrace – teplota Porovnání s odporovým snímačem teploty v kapalné lázni -80 °C až -30 °C CMC 0,12 °C -30 °C až 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C až 150 °C CMC 0,07 °C 150 °C až 260 °C CMC 0,08 °C MKTT OT.2 Termometry rezystancyjne Wzorcowanie – temperatura Porownanie z rezystancyjnym czujnikiem temperatury w lazni cieczowej od -80 °C do -30 °C CMC 0,12 °C od -30 °C do 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C od 0 °C do 150 °C CMC 0,07 °C od 150 °C do 260 °C CMC 0,08 °C Odporove teplomery Kalibrace – teplota Porovnani s odporovym snimacem teploty v kapalne lazni -80 °C az -30 °C CMC 0,12 °C -30 °C az 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C az 150 °C CMC 0,07 °C 150 °C az 260 °C CMC 0,08 °C MKTT OT.2","search_en":"Resistance thermometers Calibration – temperature Comparison with a resistance temperature sensor in a liquid bath -80 °C to -30 °C CMC 0,12 °C -30 °C to 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C to 150 °C CMC 0,07 °C 150 °C to 260 °C CMC 0,08 °C MKTT OT.2","search_zh":"电阻温度计 校准 – 温度 在液体槽中与电阻温度传感器比较 -80 °C 至 -30 °C CMC 0,12 °C -30 °C 至 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C 至 150 °C CMC 0,07 °C 150 °C 至 260 °C CMC 0,08 °C MKTT OT.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e0da563d3602549cb285c7ef","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Termometry rezystancyjne","test_object_en":"Resistance thermometers","test_object_zh":"电阻温度计","test_object_cs":"Odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 260 °C do 420 °C","cmc":"0,4 °C"},{"name":"","range":"od 420 °C do 660 °C","cmc":"0,65 °C"}],"parameters_en":[{"name":"","range":"260 °C to 420 °C","cmc":"0,4 °C"},{"name":"","range":"420 °C to 660 °C","cmc":"0,65 °C"}],"parameters_zh":[{"name":"","range":"260 °C 至 420 °C","cmc":"0,4 °C"},{"name":"","range":"420 °C 至 660 °C","cmc":"0,65 °C"}],"parameters_cs":[{"name":"","range":"260 °C až 420 °C","cmc":"0,4 °C"},{"name":"","range":"420 °C až 660 °C","cmc":"0,65 °C"}],"technique":"Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym","technique_en":"Comparison with a resistance temperature sensor in a calibrating oven","technique_zh":"在校准炉中与电阻温度传感器比较","technique_cs":"Porovnání s odporovým snímačem teploty v kalibrační pícce","techniques":["Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym"],"techniques_en":["Comparison with a resistance temperature sensor in a calibrating oven"],"techniques_zh":["在校准炉中与电阻温度传感器比较"],"techniques_cs":["Porovnání s odporovým snímačem teploty v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 260 °C do 420 °C CMC 0,4 °C\nod 420 °C do 660 °C CMC 0,65 °C\nPorównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym","reference":"MKTT OT.2","norm_bases":["MKTT OT.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry rezystancyjne Wzorcowanie – temperatura Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym od 260 °C do 420 °C CMC 0,4 °C od 420 °C do 660 °C CMC 0,65 °C Odporové teploměry Kalibrace – teplota Porovnání s odporovým snímačem teploty v kalibrační pícce 260 °C až 420 °C CMC 0,4 °C 420 °C až 660 °C CMC 0,65 °C MKTT OT.2 Termometry rezystancyjne Wzorcowanie – temperatura Porownanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym od 260 °C do 420 °C CMC 0,4 °C od 420 °C do 660 °C CMC 0,65 °C Odporove teplomery Kalibrace – teplota Porovnani s odporovym snimacem teploty v kalibracni picce 260 °C az 420 °C CMC 0,4 °C 420 °C az 660 °C CMC 0,65 °C MKTT OT.2","search_en":"Resistance thermometers Calibration – temperature Comparison with a resistance temperature sensor in a calibrating oven 260 °C to 420 °C CMC 0,4 °C 420 °C to 660 °C CMC 0,65 °C MKTT OT.2","search_zh":"电阻温度计 校准 – 温度 在校准炉中与电阻温度传感器比较 260 °C 至 420 °C CMC 0,4 °C 420 °C 至 660 °C CMC 0,65 °C MKTT OT.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"85191ddc876a5e876274be53","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermocouple temperature sensors","test_object_zh":"热电偶温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do 420 °C","cmc":"0,5 °C"},{"name":"","range":"od 420 °C do 660 °C","cmc":"0,7 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 420 °C","cmc":"0,5 °C"},{"name":"","range":"420 °C to 660 °C","cmc":"0,7 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 420 °C","cmc":"0,5 °C"},{"name":"","range":"420 °C 至 660 °C","cmc":"0,7 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až 420 °C","cmc":"0,5 °C"},{"name":"","range":"420 °C až 660 °C","cmc":"0,7 °C"}],"technique":"Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym","technique_en":"Comparison with a resistance temperature sensor in a calibrating oven","technique_zh":"在校准炉中与电阻温度传感器比较","technique_cs":"Porovnání s odporovým snímačem teploty v kalibrační pícce","techniques":["Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym"],"techniques_en":["Comparison with a resistance temperature sensor in a calibrating oven"],"techniques_zh":["在校准炉中与电阻温度传感器比较"],"techniques_cs":["Porovnání s odporovým snímačem teploty v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do 420 °C CMC 0,5 °C\nod 420 °C do 660 °C CMC 0,7 °C\nPorównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym","reference":"MKTT TE.2","norm_bases":["MKTT TE.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym od -80 °C do 420 °C CMC 0,5 °C od 420 °C do 660 °C CMC 0,7 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s odporovým snímačem teploty v kalibrační pícce -80 °C až 420 °C CMC 0,5 °C 420 °C až 660 °C CMC 0,7 °C MKTT TE.2 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym od -80 °C do 420 °C CMC 0,5 °C od 420 °C do 660 °C CMC 0,7 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s odporovym snimacem teploty v kalibracni picce -80 °C az 420 °C CMC 0,5 °C 420 °C az 660 °C CMC 0,7 °C MKTT TE.2","search_en":"Thermocouple temperature sensors Calibration – temperature Comparison with a resistance temperature sensor in a calibrating oven -80 °C to 420 °C CMC 0,5 °C 420 °C to 660 °C CMC 0,7 °C MKTT TE.2","search_zh":"热电偶温度传感器 校准 – 温度 在校准炉中与电阻温度传感器比较 -80 °C 至 420 °C CMC 0,5 °C 420 °C 至 660 °C CMC 0,7 °C MKTT TE.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3476dc09f3383bc68f1b382d","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"2","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermocouple temperature sensors","test_object_zh":"热电偶温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 660 °C do 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"od 1 100 °C do 1 300 °C","cmc":"2,0 °C"}],"parameters_en":[{"name":"","range":"660 °C to 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"1 100 °C to 1 300 °C","cmc":"2,0 °C"}],"parameters_zh":[{"name":"","range":"660 °C 至 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"1 100 °C 至 1 300 °C","cmc":"2,0 °C"}],"parameters_cs":[{"name":"","range":"660 °C až 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"1 100 °C až 1 300 °C","cmc":"2,0 °C"}],"technique":"Porównanie z czujnikiem termoelektrycznym w piecu poziomym","technique_en":"Comparison with a thermoelectric temperature sensor in a horizontal furnace","technique_zh":"在卧式炉中与热电偶温度传感器比较","technique_cs":"Porovnání s termoelektrickým snímačem teploty v horizontální peci","techniques":["Porównanie z czujnikiem termoelektrycznym w piecu poziomym"],"techniques_en":["Comparison with a thermoelectric temperature sensor in a horizontal furnace"],"techniques_zh":["在卧式炉中与热电偶温度传感器比较"],"techniques_cs":["Porovnání s termoelektrickým snímačem teploty v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 660 °C do 1 100 °C CMC 1,5 °C\nod 1 100 °C do 1 300 °C CMC 2,0 °C\nPorównanie z czujnikiem termoelektrycznym w piecu poziomym","reference":"MKTT TE.2","norm_bases":["MKTT TE.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z czujnikiem termoelektrycznym w piecu poziomym od 660 °C do 1 100 °C CMC 1,5 °C od 1 100 °C do 1 300 °C CMC 2,0 °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s termoelektrickým snímačem teploty v horizontální peci 660 °C až 1 100 °C CMC 1,5 °C 1 100 °C až 1 300 °C CMC 2,0 °C MKTT TE.2 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z czujnikiem termoelektrycznym w piecu poziomym od 660 °C do 1 100 °C CMC 1,5 °C od 1 100 °C do 1 300 °C CMC 2,0 °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s termoelektrickym snimacem teploty v horizontalni peci 660 °C az 1 100 °C CMC 1,5 °C 1 100 °C az 1 300 °C CMC 2,0 °C MKTT TE.2","search_en":"Thermocouple temperature sensors Calibration – temperature Comparison with a thermoelectric temperature sensor in a horizontal furnace 660 °C to 1 100 °C CMC 1,5 °C 1 100 °C to 1 300 °C CMC 2,0 °C MKTT TE.2","search_zh":"热电偶温度传感器 校准 – 温度 在卧式炉中与热电偶温度传感器比较 660 °C 至 1 100 °C CMC 1,5 °C 1 100 °C 至 1 300 °C CMC 2,0 °C MKTT TE.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fbae06f2a1b64b44c8475480","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"3","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -80 °C do -20 °C","cmc":"0,12 °C"},{"name":"","range":"od -20 °C do 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"od 0 °C do 150 °C","cmc":"0,07 °C"},{"name":"","range":"od 150 °C do 260 °C","cmc":"0,08 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -20 °C","cmc":"0,12 °C"},{"name":"","range":"-20 °C to 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C to 150 °C","cmc":"0,07 °C"},{"name":"","range":"150 °C to 260 °C","cmc":"0,08 °C"}],"parameters_zh":[{"name":"","range":"-80 °C 至 -20 °C","cmc":"0,12 °C"},{"name":"","range":"-20 °C 至 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C 至 150 °C","cmc":"0,07 °C"},{"name":"","range":"150 °C 至 260 °C","cmc":"0,08 °C"}],"parameters_cs":[{"name":"","range":"-80 °C až -20 °C","cmc":"0,12 °C"},{"name":"","range":"-20 °C až 0 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,05 °C"},{"name":"","range":"0 °C až 150 °C","cmc":"0,07 °C"},{"name":"","range":"150 °C až 260 °C","cmc":"0,08 °C"}],"technique":"Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej","technique_en":"Comparison with a resistance temperature sensor in a liquid bath","technique_zh":"在液体槽中与电阻温度传感器比较","technique_cs":"Porovnání s odporovým snímačem teploty v kapalinové lázni","techniques":["Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej"],"techniques_en":["Comparison with a resistance temperature sensor in a liquid bath"],"techniques_zh":["在液体槽中与电阻温度传感器比较"],"techniques_cs":["Porovnání s odporovým snímačem teploty v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -80 °C do -20 °C CMC 0,12 °C\nod -20 °C do 0 °C CMC 0,08 °C\n0 °C CMC 0,05 °C\nod 0 °C do 150 °C CMC 0,07 °C\nod 150 °C do 260 °C CMC 0,08 °C\nPorównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej","reference":"MKTT ET.2","norm_bases":["MKTT ET.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej od -80 °C do -20 °C CMC 0,12 °C od -20 °C do 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C od 0 °C do 150 °C CMC 0,07 °C od 150 °C do 260 °C CMC 0,08 °C Elektronické teploměry Kalibrace – teplota Porovnání s odporovým snímačem teploty v kapalinové lázni -80 °C až -20 °C CMC 0,12 °C -20 °C až 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C až 150 °C CMC 0,07 °C 150 °C až 260 °C CMC 0,08 °C MKTT ET.2 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z rezystancyjnym czujnikiem temperatury w lazni cieczowej od -80 °C do -20 °C CMC 0,12 °C od -20 °C do 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C od 0 °C do 150 °C CMC 0,07 °C od 150 °C do 260 °C CMC 0,08 °C Elektronicke teplomery Kalibrace – teplota Porovnani s odporovym snimacem teploty v kapalinove lazni -80 °C az -20 °C CMC 0,12 °C -20 °C az 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C az 150 °C CMC 0,07 °C 150 °C az 260 °C CMC 0,08 °C MKTT ET.2","search_en":"Electronic thermometers Calibration – temperature Comparison with a resistance temperature sensor in a liquid bath -80 °C to -20 °C CMC 0,12 °C -20 °C to 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C to 150 °C CMC 0,07 °C 150 °C to 260 °C CMC 0,08 °C MKTT ET.2","search_zh":"电子温度计 校准 – 温度 在液体槽中与电阻温度传感器比较 -80 °C 至 -20 °C CMC 0,12 °C -20 °C 至 0 °C CMC 0,08 °C 0 °C CMC 0,05 °C 0 °C 至 150 °C CMC 0,07 °C 150 °C 至 260 °C CMC 0,08 °C MKTT ET.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"12d58fd599c93e4cbe4e4bd2","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"3","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 260 °C do 420 °C","cmc":"0,4 °C"},{"name":"","range":"od 420 °C do 660 °C","cmc":"0,65 °C"}],"parameters_en":[{"name":"","range":"260 °C to 420 °C","cmc":"0,4 °C"},{"name":"","range":"420 °C to 660 °C","cmc":"0,65 °C"}],"parameters_zh":[{"name":"","range":"260 °C 至 420 °C","cmc":"0,4 °C"},{"name":"","range":"420 °C 至 660 °C","cmc":"0,65 °C"}],"parameters_cs":[{"name":"","range":"260 °C až 420 °C","cmc":"0,4 °C"},{"name":"","range":"420 °C až 660 °C","cmc":"0,65 °C"}],"technique":"Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym","technique_en":"Comparison with a resistance temperature sensor in a calibrating oven","technique_zh":"在校准炉中与电阻温度传感器比较","technique_cs":"Porovnání s odporovým snímačem teploty v kalibrační pícce","techniques":["Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym"],"techniques_en":["Comparison with a resistance temperature sensor in a calibrating oven"],"techniques_zh":["在校准炉中与电阻温度传感器比较"],"techniques_cs":["Porovnání s odporovým snímačem teploty v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 260 °C do 420 °C CMC 0,4 °C\nod 420 °C do 660 °C CMC 0,65 °C\nPorównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym","reference":"MKTT ET.2","norm_bases":["MKTT ET.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym od 260 °C do 420 °C CMC 0,4 °C od 420 °C do 660 °C CMC 0,65 °C Elektronické teploměry Kalibrace – teplota Porovnání s odporovým snímačem teploty v kalibrační pícce 260 °C až 420 °C CMC 0,4 °C 420 °C až 660 °C CMC 0,65 °C MKTT ET.2 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z rezystancyjnym czujnikiem temperatury w piecu kalibracyjnym od 260 °C do 420 °C CMC 0,4 °C od 420 °C do 660 °C CMC 0,65 °C Elektronicke teplomery Kalibrace – teplota Porovnani s odporovym snimacem teploty v kalibracni picce 260 °C az 420 °C CMC 0,4 °C 420 °C az 660 °C CMC 0,65 °C MKTT ET.2","search_en":"Electronic thermometers Calibration – temperature Comparison with a resistance temperature sensor in a calibrating oven 260 °C to 420 °C CMC 0,4 °C 420 °C to 660 °C CMC 0,65 °C MKTT ET.2","search_zh":"电子温度计 校准 – 温度 在校准炉中与电阻温度传感器比较 260 °C 至 420 °C CMC 0,4 °C 420 °C 至 660 °C CMC 0,65 °C MKTT ET.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f447c27d02eddc7603bc0eb6","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"3","test_object":"Termometry elektroniczne","test_object_en":"Electronic thermometers","test_object_zh":"电子温度计","test_object_cs":"Elektronické teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 660 °C do 1 000 °C","cmc":"1,4 °C"},{"name":"","range":"od 1 000 °C do 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"od 1 100 °C do 1 300 °C","cmc":"2,0 °C"}],"parameters_en":[{"name":"","range":"660 °C to 1 000 °C","cmc":"1,4 °C"},{"name":"","range":"1 000 °C to 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"1 100 °C to 1 300 °C","cmc":"2,0 °C"}],"parameters_zh":[{"name":"","range":"660 °C 至 1 000 °C","cmc":"1,4 °C"},{"name":"","range":"1 000 °C 至 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"1 100 °C 至 1 300 °C","cmc":"2,0 °C"}],"parameters_cs":[{"name":"","range":"660 °C až 1 000 °C","cmc":"1,4 °C"},{"name":"","range":"1 000 °C až 1 100 °C","cmc":"1,5 °C"},{"name":"","range":"1 100 °C až 1 300 °C","cmc":"2,0 °C"}],"technique":"Porównanie z czujnikiem termoelektrycznym w piecu poziomym","technique_en":"Comparison with a thermoelectric temperature sensor in a horizontal furnace","technique_zh":"在卧式炉中与热电偶温度传感器比较","technique_cs":"Porovnání s termoelektrickým snímačem teploty v horizontální peci","techniques":["Porównanie z czujnikiem termoelektrycznym w piecu poziomym"],"techniques_en":["Comparison with a thermoelectric temperature sensor in a horizontal furnace"],"techniques_zh":["在卧式炉中与热电偶温度传感器比较"],"techniques_cs":["Porovnání s termoelektrickým snímačem teploty v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 660 °C do 1 000 °C CMC 1,4 °C\nod 1 000 °C do 1 100 °C CMC 1,5 °C\nod 1 100 °C do 1 300 °C CMC 2,0 °C\nPorównanie z czujnikiem termoelektrycznym w piecu poziomym","reference":"MKTT ET.2","norm_bases":["MKTT ET.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry elektroniczne Wzorcowanie – temperatura Porównanie z czujnikiem termoelektrycznym w piecu poziomym od 660 °C do 1 000 °C CMC 1,4 °C od 1 000 °C do 1 100 °C CMC 1,5 °C od 1 100 °C do 1 300 °C CMC 2,0 °C Elektronické teploměry Kalibrace – teplota Porovnání s termoelektrickým snímačem teploty v horizontální peci 660 °C až 1 000 °C CMC 1,4 °C 1 000 °C až 1 100 °C CMC 1,5 °C 1 100 °C až 1 300 °C CMC 2,0 °C MKTT ET.2 Termometry elektroniczne Wzorcowanie – temperatura Porownanie z czujnikiem termoelektrycznym w piecu poziomym od 660 °C do 1 000 °C CMC 1,4 °C od 1 000 °C do 1 100 °C CMC 1,5 °C od 1 100 °C do 1 300 °C CMC 2,0 °C Elektronicke teplomery Kalibrace – teplota Porovnani s termoelektrickym snimacem teploty v horizontalni peci 660 °C az 1 000 °C CMC 1,4 °C 1 000 °C az 1 100 °C CMC 1,5 °C 1 100 °C az 1 300 °C CMC 2,0 °C MKTT ET.2","search_en":"Electronic thermometers Calibration – temperature Comparison with a thermoelectric temperature sensor in a horizontal furnace 660 °C to 1 000 °C CMC 1,4 °C 1 000 °C to 1 100 °C CMC 1,5 °C 1 100 °C to 1 300 °C CMC 2,0 °C MKTT ET.2","search_zh":"电子温度计 校准 – 温度 在卧式炉中与热电偶温度传感器比较 660 °C 至 1 000 °C CMC 1,4 °C 1 000 °C 至 1 100 °C CMC 1,5 °C 1 100 °C 至 1 300 °C CMC 2,0 °C MKTT ET.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"53da0c99ab65d576169ddd6b","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"4","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do -20 °C","cmc":"0,12 °C"},{"name":"","range":"od -20 °C do 200 °C","cmc":"0,07 °C"},{"name":"","range":"od 200 °C do 300 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"-40 °C to -20 °C","cmc":"0,12 °C"},{"name":"","range":"-20 °C to 200 °C","cmc":"0,07 °C"},{"name":"","range":"200 °C to 300 °C","cmc":"0,15 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 -20 °C","cmc":"0,12 °C"},{"name":"","range":"-20 °C 至 200 °C","cmc":"0,07 °C"},{"name":"","range":"200 °C 至 300 °C","cmc":"0,15 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až -20 °C","cmc":"0,12 °C"},{"name":"","range":"-20 °C až 200 °C","cmc":"0,07 °C"},{"name":"","range":"200 °C až 300 °C","cmc":"0,15 °C"}],"technique":"Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej","technique_en":"Comparison with a resistance temperature sensor in a liquid bath","technique_zh":"在液体槽中与电阻温度传感器比较","technique_cs":"Porovnání s odporovým snímačem teploty v kapalinové lázni","techniques":["Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej"],"techniques_en":["Comparison with a resistance temperature sensor in a liquid bath"],"techniques_zh":["在液体槽中与电阻温度传感器比较"],"techniques_cs":["Porovnání s odporovým snímačem teploty v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -40 °C do -20 °C CMC 0,12 °C\nod -20 °C do 200 °C CMC 0,07 °C\nod 200 °C do 300 °C CMC 0,15 °C\nPorównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej","reference":"MKTT ST.2","norm_bases":["MKTT ST.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z rezystancyjnym czujnikiem temperatury w łaźni cieczowej od -40 °C do -20 °C CMC 0,12 °C od -20 °C do 200 °C CMC 0,07 °C od 200 °C do 300 °C CMC 0,15 °C Skleněné teploměry Kalibrace – teplota Porovnání s odporovým snímačem teploty v kapalinové lázni -40 °C až -20 °C CMC 0,12 °C -20 °C až 200 °C CMC 0,07 °C 200 °C až 300 °C CMC 0,15 °C MKTT ST.2 Termometry szklane Wzorcowanie – temperatura Porownanie z rezystancyjnym czujnikiem temperatury w lazni cieczowej od -40 °C do -20 °C CMC 0,12 °C od -20 °C do 200 °C CMC 0,07 °C od 200 °C do 300 °C CMC 0,15 °C Sklenene teplomery Kalibrace – teplota Porovnani s odporovym snimacem teploty v kapalinove lazni -40 °C az -20 °C CMC 0,12 °C -20 °C az 200 °C CMC 0,07 °C 200 °C az 300 °C CMC 0,15 °C MKTT ST.2","search_en":"Glass thermometers Calibration – temperature Comparison with a resistance temperature sensor in a liquid bath -40 °C to -20 °C CMC 0,12 °C -20 °C to 200 °C CMC 0,07 °C 200 °C to 300 °C CMC 0,15 °C MKTT ST.2","search_zh":"玻璃温度计 校准 – 温度 在液体槽中与电阻温度传感器比较 -40 °C 至 -20 °C CMC 0,12 °C -20 °C 至 200 °C CMC 0,07 °C 200 °C 至 300 °C CMC 0,15 °C MKTT ST.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77240ecc6438b2ff92a4f149","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"5","test_object":"Termometry bezdotykowe","test_object_en":"Non-contact thermometers","test_object_zh":"非接触式温度计","test_object_cs":"Bezdotykové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -20 °C do 300 °C","cmc":"1,2 °C"},{"name":"","range":"od 300 °C do 1100 °C","cmc":"0,6 %"}],"parameters_en":[{"name":"","range":"-20 °C to 300 °C","cmc":"1,2 °C"},{"name":"","range":"300 °C to 1100 °C","cmc":"0,6 %"}],"parameters_zh":[{"name":"","range":"-20 °C 至 300 °C","cmc":"1,2 °C"},{"name":"","range":"300 °C 至 1100 °C","cmc":"0,6 %"}],"parameters_cs":[{"name":"","range":"-20 °C až 300 °C","cmc":"1,2 °C"},{"name":"","range":"300 °C až 1100 °C","cmc":"0,6 %"}],"technique":"Porównanie z wzorcowym ciałem czarnym","technique_en":"Comparison with a standard black body","technique_zh":"与标准黑体比较","technique_cs":"Porovnání s etalonovým černým tělesem","techniques":["Porównanie z wzorcowym ciałem czarnym"],"techniques_en":["Comparison with a standard black body"],"techniques_zh":["与标准黑体比较"],"techniques_cs":["Porovnání s etalonovým černým tělesem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -20 °C do 300 °C CMC 1,2 °C\nod 300 °C do 1100 °C CMC 0,6 %\nPorównanie z wzorcowym ciałem czarnym","reference":"MKTT PR.1","norm_bases":["MKTT PR.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezdotykowe Wzorcowanie – temperatura Porównanie z wzorcowym ciałem czarnym od -20 °C do 300 °C CMC 1,2 °C od 300 °C do 1100 °C CMC 0,6 % Bezdotykové teploměry Kalibrace – teplota Porovnání s etalonovým černým tělesem -20 °C až 300 °C CMC 1,2 °C 300 °C až 1100 °C CMC 0,6 % MKTT PR.1 Termometry bezdotykowe Wzorcowanie – temperatura Porownanie z wzorcowym cialem czarnym od -20 °C do 300 °C CMC 1,2 °C od 300 °C do 1100 °C CMC 0,6 % Bezdotykove teplomery Kalibrace – teplota Porovnani s etalonovym cernym telesem -20 °C az 300 °C CMC 1,2 °C 300 °C az 1100 °C CMC 0,6 % MKTT PR.1","search_en":"Non-contact thermometers Calibration – temperature Comparison with a standard black body -20 °C to 300 °C CMC 1,2 °C 300 °C to 1100 °C CMC 0,6 % MKTT PR.1","search_zh":"非接触式温度计 校准 – 温度 与标准黑体比较 -20 °C 至 300 °C CMC 1,2 °C 300 °C 至 1100 °C CMC 0,6 % MKTT PR.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"530014986b893fafd2deb87f","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"6","test_object":"Tory pomiarowe temperatury z termoparą typu B, C, D, E, J, K, N, R, T, S, termometry rezystancyjne, wyjście napięciowe i prądowe przetworników","test_object_en":"Temperature measuring chains with thermocouple type B, C, D, E, J, K, N, R, T, S, resistance thermometers, voltage and current output of transducers","test_object_zh":"带 B、C、D、E、J、K、N、R、T、S 型热电偶的温度测量链、电阻温度计、变送器的电压和电流输出","test_object_cs":"Měřící řetězce teploty s termočlánkem typu B, C, D, E, J, K, N, R, T, S, odporové teploměry, napěťový a proudový výstup převodníků","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -200 °C do -100 °C","cmc":"0,1 %"},{"name":"","range":"od -100 °C do 100 °C","cmc":"0,1 °C"},{"name":"","range":"od 100 °C do 1800 °C","cmc":"0,1 %"}],"parameters_en":[{"name":"","range":"-200 °C to -100 °C","cmc":"0,1 %"},{"name":"","range":"-100 °C to 100 °C","cmc":"0,1 °C"},{"name":"","range":"100 °C to 1800 °C","cmc":"0,1 %"}],"parameters_zh":[{"name":"","range":"-200 °C 至 -100 °C","cmc":"0,1 %"},{"name":"","range":"-100 °C 至 100 °C","cmc":"0,1 °C"},{"name":"","range":"100 °C 至 1800 °C","cmc":"0,1 %"}],"parameters_cs":[{"name":"","range":"-200 °C až -100 °C","cmc":"0,1 %"},{"name":"","range":"-100 °C až 100 °C","cmc":"0,1 °C"},{"name":"","range":"100 °C až 1800 °C","cmc":"0,1 %"}],"technique":"Porównanie z kalibratorem lub pomiar multimetrem drogą elektryczną","technique_en":"Comparison with a calibrator or electrical measurement with a multimeter","technique_zh":"与校准器比较或用万用表进行电测量","technique_cs":"Porovnání s kalibrátorem nebo měření multimetrem elektrickou cestou","techniques":["Porównanie z kalibratorem lub pomiar multimetrem drogą elektryczną"],"techniques_en":["Comparison with a calibrator or electrical measurement with a multimeter"],"techniques_zh":["与校准器比较或用万用表进行电测量"],"techniques_cs":["Porovnání s kalibrátorem nebo měření multimetrem elektrickou cestou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -200 °C do -100 °C CMC 0,1 %\nod -100 °C do 100 °C CMC 0,1 °C\nod 100 °C do 1800 °C CMC 0,1 %\nPorównanie z kalibratorem lub pomiar multimetrem drogą elektryczną","reference":"MKTT TX.1","norm_bases":["MKTT TX.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe temperatury z termoparą typu B, C, D, E, J, K, N, R, T, S, termometry rezystancyjne, wyjście napięciowe i prądowe przetworników Wzorcowanie – temperatura Porównanie z kalibratorem lub pomiar multimetrem drogą elektryczną od -200 °C do -100 °C CMC 0,1 % od -100 °C do 100 °C CMC 0,1 °C od 100 °C do 1800 °C CMC 0,1 % Měřící řetězce teploty s termočlánkem typu B, C, D, E, J, K, N, R, T, S, odporové teploměry, napěťový a proudový výstup převodníků Kalibrace – teplota Porovnání s kalibrátorem nebo měření multimetrem elektrickou cestou -200 °C až -100 °C CMC 0,1 % -100 °C až 100 °C CMC 0,1 °C 100 °C až 1800 °C CMC 0,1 % MKTT TX.1 Tory pomiarowe temperatury z termopara typu B, C, D, E, J, K, N, R, T, S, termometry rezystancyjne, wyjscie napieciowe i pradowe przetwornikow Wzorcowanie – temperatura Porownanie z kalibratorem lub pomiar multimetrem droga elektryczna od -200 °C do -100 °C CMC 0,1 % od -100 °C do 100 °C CMC 0,1 °C od 100 °C do 1800 °C CMC 0,1 % Merici retezce teploty s termoclankem typu B, C, D, E, J, K, N, R, T, S, odporove teplomery, napetovy a proudovy vystup prevodniku Kalibrace – teplota Porovnani s kalibratorem nebo mereni multimetrem elektrickou cestou -200 °C az -100 °C CMC 0,1 % -100 °C az 100 °C CMC 0,1 °C 100 °C az 1800 °C CMC 0,1 % MKTT TX.1","search_en":"Temperature measuring chains with thermocouple type B, C, D, E, J, K, N, R, T, S, resistance thermometers, voltage and current output of transducers Calibration – temperature Comparison with a calibrator or electrical measurement with a multimeter -200 °C to -100 °C CMC 0,1 % -100 °C to 100 °C CMC 0,1 °C 100 °C to 1800 °C CMC 0,1 % MKTT TX.1","search_zh":"带 B、C、D、E、J、K、N、R、T、S 型热电偶的温度测量链、电阻温度计、变送器的电压和电流输出 校准 – 温度 与校准器比较或用万用表进行电测量 -200 °C 至 -100 °C CMC 0,1 % -100 °C 至 100 °C CMC 0,1 °C 100 °C 至 1800 °C CMC 0,1 % MKTT TX.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19e1bffb7aaa4ea8e8a14c5c","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Wilgotność względna / higrometry","test_object_en":"Relative humidity / Humidity meters","test_object_zh":"相对湿度 / 湿度计","test_object_cs":"Relativní vlhkost / Vlhkoměry","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(18 do 28) °C","range":"od 5 % RH do 10 % RH","cmc":"2,4 % RH"},{"name":"(18 do 28) °C","range":"od 10 % RH do 30 % RH","cmc":"1,2 % RH"},{"name":"(18 do 28) °C","range":"od 30 % RH do 70 % RH","cmc":"1,3 % RH"},{"name":"(18 do 28) °C","range":"od 70 % RH do 95 % RH","cmc":"1,4 % RH"},{"name":"(10 do 18) i (28 do 40) °C","range":"od 5 % RH do 50 % RH","cmc":"1,8 % RH"},{"name":"(10 do 18) i (28 do 40) °C","range":"od 50 % RH do 95 % RH","cmc":"2,4 % RH"},{"name":"(40 do 70) °C","range":"od 5 % RH do 50 % RH","cmc":"2,8 % RH"},{"name":"(40 do 70) °C","range":"od 50 % RH do 95 % RH","cmc":"3,6 % RH"}],"parameters_en":[{"name":"(18 to 28) °C","range":"5 % RH to 10 % RH","cmc":"2,4 % RH"},{"name":"(18 to 28) °C","range":"10 % RH to 30 % RH","cmc":"1,2 % RH"},{"name":"(18 to 28) °C","range":"30 % RH to 70 % RH","cmc":"1,3 % RH"},{"name":"(18 to 28) °C","range":"70 % RH to 95 % RH","cmc":"1,4 % RH"},{"name":"(10 to 18) and (28 to 40) °C","range":"5 % RH to 50 % RH","cmc":"1,8 % RH"},{"name":"(10 to 18) and (28 to 40) °C","range":"50 % RH to 95 % RH","cmc":"2,4 % RH"},{"name":"(40 to 70) °C","range":"5 % RH to 50 % RH","cmc":"2,8 % RH"},{"name":"(40 to 70) °C","range":"50 % RH to 95 % RH","cmc":"3,6 % RH"}],"parameters_zh":[{"name":"(18 至 28) °C","range":"5 % RH 至 10 % RH","cmc":"2,4 % RH"},{"name":"(18 至 28) °C","range":"10 % RH 至 30 % RH","cmc":"1,2 % RH"},{"name":"(18 至 28) °C","range":"30 % RH 至 70 % RH","cmc":"1,3 % RH"},{"name":"(18 至 28) °C","range":"70 % RH 至 95 % RH","cmc":"1,4 % RH"},{"name":"(10 至 18) 和 (28 至 40) °C","range":"5 % RH 至 50 % RH","cmc":"1,8 % RH"},{"name":"(10 至 18) 和 (28 至 40) °C","range":"50 % RH 至 95 % RH","cmc":"2,4 % RH"},{"name":"(40 至 70) °C","range":"5 % RH 至 50 % RH","cmc":"2,8 % RH"},{"name":"(40 至 70) °C","range":"50 % RH 至 95 % RH","cmc":"3,6 % RH"}],"parameters_cs":[{"name":"(18 až 28) °C","range":"5 % RH až 10 % RH","cmc":"2,4 % RH"},{"name":"(18 až 28) °C","range":"10 % RH až 30 % RH","cmc":"1,2 % RH"},{"name":"(18 až 28) °C","range":"30 % RH až 70 % RH","cmc":"1,3 % RH"},{"name":"(18 až 28) °C","range":"70 % RH až 95 % RH","cmc":"1,4 % RH"},{"name":"(10 až 18) a (28 až 40) °C","range":"5 % RH až 50 % RH","cmc":"1,8 % RH"},{"name":"(10 až 18) a (28 až 40) °C","range":"50 % RH až 95 % RH","cmc":"2,4 % RH"},{"name":"(40 až 70) °C","range":"5 % RH až 50 % RH","cmc":"2,8 % RH"},{"name":"(40 až 70) °C","range":"50 % RH až 95 % RH","cmc":"3,6 % RH"}],"technique":"Porównanie z higrometrem w komorze klimatycznej","technique_en":"Comparison with a humidity meter in a climatic chamber","technique_zh":"在气候箱中与湿度计比较","technique_cs":"Porovnání s vlhkoměrem v klimatické komoře","techniques":["Porównanie z higrometrem w komorze klimatycznej"],"techniques_en":["Comparison with a humidity meter in a climatic chamber"],"techniques_zh":["在气候箱中与湿度计比较"],"techniques_cs":["Porovnání s vlhkoměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\n(18 do 28) °C od 5 % RH do 10 % RH CMC 2,4 % RH\n(18 do 28) °C od 10 % RH do 30 % RH CMC 1,2 % RH\n(18 do 28) °C od 30 % RH do 70 % RH CMC 1,3 % RH\n(18 do 28) °C od 70 % RH do 95 % RH CMC 1,4 % RH\n(10 do 18) i (28 do 40) °C od 5 % RH do 50 % RH CMC 1,8 % RH\n(10 do 18) i (28 do 40) °C od 50 % RH do 95 % RH CMC 2,4 % RH\n(40 do 70) °C od 5 % RH do 50 % RH CMC 2,8 % RH\n(40 do 70) °C od 50 % RH do 95 % RH CMC 3,6 % RH\nPorównanie z higrometrem w komorze klimatycznej","reference":"MKRV.1","norm_bases":["MKRV.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotność względna / higrometry Wzorcowanie – wilgotność powietrza Porównanie z higrometrem w komorze klimatycznej (18 do 28) °C od 5 % RH do 10 % RH CMC 2,4 % RH (18 do 28) °C od 10 % RH do 30 % RH CMC 1,2 % RH (18 do 28) °C od 30 % RH do 70 % RH CMC 1,3 % RH (18 do 28) °C od 70 % RH do 95 % RH CMC 1,4 % RH (10 do 18) i (28 do 40) °C od 5 % RH do 50 % RH CMC 1,8 % RH (10 do 18) i (28 do 40) °C od 50 % RH do 95 % RH CMC 2,4 % RH (40 do 70) °C od 5 % RH do 50 % RH CMC 2,8 % RH (40 do 70) °C od 50 % RH do 95 % RH CMC 3,6 % RH Relativní vlhkost / Vlhkoměry Kalibrace – vlhkost vzduchu Porovnání s vlhkoměrem v klimatické komoře (18 až 28) °C 5 % RH až 10 % RH CMC 2,4 % RH (18 až 28) °C 10 % RH až 30 % RH CMC 1,2 % RH (18 až 28) °C 30 % RH až 70 % RH CMC 1,3 % RH (18 až 28) °C 70 % RH až 95 % RH CMC 1,4 % RH (10 až 18) a (28 až 40) °C 5 % RH až 50 % RH CMC 1,8 % RH (10 až 18) a (28 až 40) °C 50 % RH až 95 % RH CMC 2,4 % RH (40 až 70) °C 5 % RH až 50 % RH CMC 2,8 % RH (40 až 70) °C 50 % RH až 95 % RH CMC 3,6 % RH MKRV.1 Wilgotnosc wzgledna / higrometry Wzorcowanie – wilgotnosc powietrza Porownanie z higrometrem w komorze klimatycznej (18 do 28) °C od 5 % RH do 10 % RH CMC 2,4 % RH (18 do 28) °C od 10 % RH do 30 % RH CMC 1,2 % RH (18 do 28) °C od 30 % RH do 70 % RH CMC 1,3 % RH (18 do 28) °C od 70 % RH do 95 % RH CMC 1,4 % RH (10 do 18) i (28 do 40) °C od 5 % RH do 50 % RH CMC 1,8 % RH (10 do 18) i (28 do 40) °C od 50 % RH do 95 % RH CMC 2,4 % RH (40 do 70) °C od 5 % RH do 50 % RH CMC 2,8 % RH (40 do 70) °C od 50 % RH do 95 % RH CMC 3,6 % RH Relativni vlhkost / Vlhkomery Kalibrace – vlhkost vzduchu Porovnani s vlhkomerem v klimaticke komore (18 az 28) °C 5 % RH az 10 % RH CMC 2,4 % RH (18 az 28) °C 10 % RH az 30 % RH CMC 1,2 % RH (18 az 28) °C 30 % RH az 70 % RH CMC 1,3 % RH (18 az 28) °C 70 % RH az 95 % RH CMC 1,4 % RH (10 az 18) a (28 az 40) °C 5 % RH az 50 % RH CMC 1,8 % RH (10 az 18) a (28 az 40) °C 50 % RH az 95 % RH CMC 2,4 % RH (40 az 70) °C 5 % RH az 50 % RH CMC 2,8 % RH (40 az 70) °C 50 % RH az 95 % RH CMC 3,6 % RH MKRV.1","search_en":"Relative humidity / Humidity meters Calibration – air humidity Comparison with a humidity meter in a climatic chamber (18 to 28) °C 5 % RH to 10 % RH CMC 2,4 % RH (18 to 28) °C 10 % RH to 30 % RH CMC 1,2 % RH (18 to 28) °C 30 % RH to 70 % RH CMC 1,3 % RH (18 to 28) °C 70 % RH to 95 % RH CMC 1,4 % RH (10 to 18) and (28 to 40) °C 5 % RH to 50 % RH CMC 1,8 % RH (10 to 18) and (28 to 40) °C 50 % RH to 95 % RH CMC 2,4 % RH (40 to 70) °C 5 % RH to 50 % RH CMC 2,8 % RH (40 to 70) °C 50 % RH to 95 % RH CMC 3,6 % RH MKRV.1","search_zh":"相对湿度 / 湿度计 校准 – 空气湿度 在气候箱中与湿度计比较 (18 至 28) °C 5 % RH 至 10 % RH CMC 2,4 % RH (18 至 28) °C 10 % RH 至 30 % RH CMC 1,2 % RH (18 至 28) °C 30 % RH 至 70 % RH CMC 1,3 % RH (18 至 28) °C 70 % RH 至 95 % RH CMC 1,4 % RH (10 至 18) 和 (28 至 40) °C 5 % RH 至 50 % RH CMC 1,8 % RH (10 至 18) 和 (28 至 40) °C 50 % RH 至 95 % RH CMC 2,4 % RH (40 至 70) °C 5 % RH 至 50 % RH CMC 2,8 % RH (40 至 70) °C 50 % RH 至 95 % RH CMC 3,6 % RH MKRV.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6bb8dc64ed57ff3affad7f1a","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"DC voltage / Power supplies, calibrators, inspection instruments","test_object_zh":"直流电压 / 电源、校准器、电气安装检测仪","test_object_cs":"Stejnosměrné napětí / Zdroje, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 1 mV","cmc":"0,50 µV"},{"name":"","range":"od 1 mV do 10 mV","cmc":"0,032 %"},{"name":"","range":"od 10 mV do 100 mV","cmc":"0,0040 %"},{"name":"","range":"od 100 mV do 1 V","cmc":"0,0008 %"},{"name":"","range":"od 1 V do 1,9 V","cmc":"0,0005 %"},{"name":"","range":"od 1,9 V do 7 V","cmc":"0,0007 %"},{"name":"","range":"od 7 V do 19 V","cmc":"0,0005 %"},{"name":"","range":"od 19 V do 50 V","cmc":"0,0008 %"},{"name":"","range":"od 50 V do 190 V","cmc":"0,0007 %"},{"name":"","range":"od 190 V do 1000 V","cmc":"0,0009 %"},{"name":"","range":"1000 V","cmc":"0,0007 %"}],"parameters_en":[{"name":"","range":"0 mV to 1 mV","cmc":"0,50 µV"},{"name":"","range":"1 mV to 10 mV","cmc":"0,032 %"},{"name":"","range":"10 mV to 100 mV","cmc":"0,0040 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,0008 %"},{"name":"","range":"1 V to 1,9 V","cmc":"0,0005 %"},{"name":"","range":"1,9 V to 7 V","cmc":"0,0007 %"},{"name":"","range":"7 V to 19 V","cmc":"0,0005 %"},{"name":"","range":"19 V to 50 V","cmc":"0,0008 %"},{"name":"","range":"50 V to 190 V","cmc":"0,0007 %"},{"name":"","range":"190 V to 1000 V","cmc":"0,0009 %"},{"name":"","range":"1000 V","cmc":"0,0007 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 1 mV","cmc":"0,50 µV"},{"name":"","range":"1 mV 至 10 mV","cmc":"0,032 %"},{"name":"","range":"10 mV 至 100 mV","cmc":"0,0040 %"},{"name":"","range":"100 mV 至 1 V","cmc":"0,0008 %"},{"name":"","range":"1 V 至 1,9 V","cmc":"0,0005 %"},{"name":"","range":"1,9 V 至 7 V","cmc":"0,0007 %"},{"name":"","range":"7 V 至 19 V","cmc":"0,0005 %"},{"name":"","range":"19 V 至 50 V","cmc":"0,0008 %"},{"name":"","range":"50 V 至 190 V","cmc":"0,0007 %"},{"name":"","range":"190 V 至 1000 V","cmc":"0,0009 %"},{"name":"","range":"1000 V","cmc":"0,0007 %"}],"parameters_cs":[{"name":"","range":"0 mV až 1 mV","cmc":"0,50 µV"},{"name":"","range":"1 mV až 10 mV","cmc":"0,032 %"},{"name":"","range":"10 mV až 100 mV","cmc":"0,0040 %"},{"name":"","range":"100 mV až 1 V","cmc":"0,0008 %"},{"name":"","range":"1 V až 1,9 V","cmc":"0,0005 %"},{"name":"","range":"1,9 V až 7 V","cmc":"0,0007 %"},{"name":"","range":"7 V až 19 V","cmc":"0,0005 %"},{"name":"","range":"19 V až 50 V","cmc":"0,0008 %"},{"name":"","range":"50 V až 190 V","cmc":"0,0007 %"},{"name":"","range":"190 V až 1000 V","cmc":"0,0009 %"},{"name":"","range":"1000 V","cmc":"0,0007 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 1 mV CMC 0,50 µV\nod 1 mV do 10 mV CMC 0,032 %\nod 10 mV do 100 mV CMC 0,0040 %\nod 100 mV do 1 V CMC 0,0008 %\nod 1 V do 1,9 V CMC 0,0005 %\nod 1,9 V do 7 V CMC 0,0007 %\nod 7 V do 19 V CMC 0,0005 %\nod 19 V do 50 V CMC 0,0008 %\nod 50 V do 190 V CMC 0,0007 %\nod 190 V do 1000 V CMC 0,0009 %\n1000 V CMC 0,0007 %\nPomiar bezpośredni multimetrem","reference":"MKE-USS1, MKE-SRP.1","norm_bases":["MKE-USS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 mV do 1 mV CMC 0,50 µV od 1 mV do 10 mV CMC 0,032 % od 10 mV do 100 mV CMC 0,0040 % od 100 mV do 1 V CMC 0,0008 % od 1 V do 1,9 V CMC 0,0005 % od 1,9 V do 7 V CMC 0,0007 % od 7 V do 19 V CMC 0,0005 % od 19 V do 50 V CMC 0,0008 % od 50 V do 190 V CMC 0,0007 % od 190 V do 1000 V CMC 0,0009 % 1000 V CMC 0,0007 % Stejnosměrné napětí / Zdroje, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé měření multimetrem 0 mV až 1 mV CMC 0,50 µV 1 mV až 10 mV CMC 0,032 % 10 mV až 100 mV CMC 0,0040 % 100 mV až 1 V CMC 0,0008 % 1 V až 1,9 V CMC 0,0005 % 1,9 V až 7 V CMC 0,0007 % 7 V až 19 V CMC 0,0005 % 19 V až 50 V CMC 0,0008 % 50 V až 190 V CMC 0,0007 % 190 V až 1000 V CMC 0,0009 % 1000 V CMC 0,0007 % MKE-USS1, MKE-SRP.1 Napiecie stale / zasilacze, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 mV do 1 mV CMC 0,50 µV od 1 mV do 10 mV CMC 0,032 % od 10 mV do 100 mV CMC 0,0040 % od 100 mV do 1 V CMC 0,0008 % od 1 V do 1,9 V CMC 0,0005 % od 1,9 V do 7 V CMC 0,0007 % od 7 V do 19 V CMC 0,0005 % od 19 V do 50 V CMC 0,0008 % od 50 V do 190 V CMC 0,0007 % od 190 V do 1000 V CMC 0,0009 % 1000 V CMC 0,0007 % Stejnosmerne napeti / Zdroje, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime mereni multimetrem 0 mV az 1 mV CMC 0,50 µV 1 mV az 10 mV CMC 0,032 % 10 mV az 100 mV CMC 0,0040 % 100 mV az 1 V CMC 0,0008 % 1 V az 1,9 V CMC 0,0005 % 1,9 V az 7 V CMC 0,0007 % 7 V az 19 V CMC 0,0005 % 19 V az 50 V CMC 0,0008 % 50 V az 190 V CMC 0,0007 % 190 V az 1000 V CMC 0,0009 % 1000 V CMC 0,0007 % MKE-USS1, MKE-SRP.1","search_en":"DC voltage / Power supplies, calibrators, inspection instruments Calibration – electrical quantities Direct measurement using a multimeter 0 mV to 1 mV CMC 0,50 µV 1 mV to 10 mV CMC 0,032 % 10 mV to 100 mV CMC 0,0040 % 100 mV to 1 V CMC 0,0008 % 1 V to 1,9 V CMC 0,0005 % 1,9 V to 7 V CMC 0,0007 % 7 V to 19 V CMC 0,0005 % 19 V to 50 V CMC 0,0008 % 50 V to 190 V CMC 0,0007 % 190 V to 1000 V CMC 0,0009 % 1000 V CMC 0,0007 % MKE-USS1, MKE-SRP.1","search_zh":"直流电压 / 电源、校准器、电气安装检测仪 校准 – 电学量 用万用表直接测量 0 mV 至 1 mV CMC 0,50 µV 1 mV 至 10 mV CMC 0,032 % 10 mV 至 100 mV CMC 0,0040 % 100 mV 至 1 V CMC 0,0008 % 1 V 至 1,9 V CMC 0,0005 % 1,9 V 至 7 V CMC 0,0007 % 7 V 至 19 V CMC 0,0005 % 19 V 至 50 V CMC 0,0008 % 50 V 至 190 V CMC 0,0007 % 190 V 至 1000 V CMC 0,0009 % 1000 V CMC 0,0007 % MKE-USS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c66778dbd3d8f8033473fe52","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"2","test_object":"Napięcie stałe / woltomierze, multimetry, mierniki do badań instalacji elektrycznych","test_object_en":"DC voltage / voltmeters, multimeters and inspection equipment","test_object_zh":"直流电压 / 电压表、万用表、电气安装检测仪","test_object_cs":"Stejnosměrné napětí / voltmetry, multimetry, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 mV do 10 mV","cmc":"0,060 %"},{"name":"","range":"od 10 mV do 100 mV","cmc":"0,0065 %"},{"name":"","range":"od 100 mV do 220 mV","cmc":"0,0015 %"},{"name":"","range":"od 220 mV do 2,2 V","cmc":"0,0012 %"},{"name":"","range":"od 2,2 V do 22 V","cmc":"0,0007 %"},{"name":"","range":"od 22 V do 1000 V","cmc":"0,0010 %"}],"parameters_en":[{"name":"","range":"1 mV to 10 mV","cmc":"0,060 %"},{"name":"","range":"10 mV to 100 mV","cmc":"0,0065 %"},{"name":"","range":"100 mV to 220 mV","cmc":"0,0015 %"},{"name":"","range":"220 mV to 2,2 V","cmc":"0,0012 %"},{"name":"","range":"2,2 V to 22 V","cmc":"0,0007 %"},{"name":"","range":"22 V to 1000 V","cmc":"0,0010 %"}],"parameters_zh":[{"name":"","range":"1 mV 至 10 mV","cmc":"0,060 %"},{"name":"","range":"10 mV 至 100 mV","cmc":"0,0065 %"},{"name":"","range":"100 mV 至 220 mV","cmc":"0,0015 %"},{"name":"","range":"220 mV 至 2,2 V","cmc":"0,0012 %"},{"name":"","range":"2,2 V 至 22 V","cmc":"0,0007 %"},{"name":"","range":"22 V 至 1000 V","cmc":"0,0010 %"}],"parameters_cs":[{"name":"","range":"1 mV až 10 mV","cmc":"0,060 %"},{"name":"","range":"10 mV až 100 mV","cmc":"0,0065 %"},{"name":"","range":"100 mV až 220 mV","cmc":"0,0015 %"},{"name":"","range":"220 mV až 2,2 V","cmc":"0,0012 %"},{"name":"","range":"2,2 V až 22 V","cmc":"0,0007 %"},{"name":"","range":"22 V až 1000 V","cmc":"0,0010 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 mV do 10 mV CMC 0,060 %\nod 10 mV do 100 mV CMC 0,0065 %\nod 100 mV do 220 mV CMC 0,0015 %\nod 220 mV do 2,2 V CMC 0,0012 %\nod 2,2 V do 22 V CMC 0,0007 %\nod 22 V do 1000 V CMC 0,0010 %\nBezpośrednie generowanie kalibratorem","reference":"MKE-USS1, MKE-SRP.1","norm_bases":["MKE-USS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / woltomierze, multimetry, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 1 mV do 10 mV CMC 0,060 % od 10 mV do 100 mV CMC 0,0065 % od 100 mV do 220 mV CMC 0,0015 % od 220 mV do 2,2 V CMC 0,0012 % od 2,2 V do 22 V CMC 0,0007 % od 22 V do 1000 V CMC 0,0010 % Stejnosměrné napětí / voltmetry, multimetry, revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 1 mV až 10 mV CMC 0,060 % 10 mV až 100 mV CMC 0,0065 % 100 mV až 220 mV CMC 0,0015 % 220 mV až 2,2 V CMC 0,0012 % 2,2 V až 22 V CMC 0,0007 % 22 V až 1000 V CMC 0,0010 % MKE-USS1, MKE-SRP.1 Napiecie stale / woltomierze, multimetry, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 1 mV do 10 mV CMC 0,060 % od 10 mV do 100 mV CMC 0,0065 % od 100 mV do 220 mV CMC 0,0015 % od 220 mV do 2,2 V CMC 0,0012 % od 2,2 V do 22 V CMC 0,0007 % od 22 V do 1000 V CMC 0,0010 % Stejnosmerne napeti / voltmetry, multimetry, revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 1 mV az 10 mV CMC 0,060 % 10 mV az 100 mV CMC 0,0065 % 100 mV az 220 mV CMC 0,0015 % 220 mV az 2,2 V CMC 0,0012 % 2,2 V az 22 V CMC 0,0007 % 22 V az 1000 V CMC 0,0010 % MKE-USS1, MKE-SRP.1","search_en":"DC voltage / voltmeters, multimeters and inspection equipment Calibration – electrical quantities Direct generation with a calibrator 1 mV to 10 mV CMC 0,060 % 10 mV to 100 mV CMC 0,0065 % 100 mV to 220 mV CMC 0,0015 % 220 mV to 2,2 V CMC 0,0012 % 2,2 V to 22 V CMC 0,0007 % 22 V to 1000 V CMC 0,0010 % MKE-USS1, MKE-SRP.1","search_zh":"直流电压 / 电压表、万用表、电气安装检测仪 校准 – 电学量 用校准器直接产生 1 mV 至 10 mV CMC 0,060 % 10 mV 至 100 mV CMC 0,0065 % 100 mV 至 220 mV CMC 0,0015 % 220 mV 至 2,2 V CMC 0,0012 % 2,2 V 至 22 V CMC 0,0007 % 22 V 至 1000 V CMC 0,0010 % MKE-USS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6cf5900618e4786e08e66477","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"AC voltage / Power supplies, calibrators, inspection instruments","test_object_zh":"交流电压 / 电源、校准器、电气安装检测仪","test_object_cs":"Střídavé napětí / Zdroje, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 10 kHz","range":"od 2 mV do 10 mV","cmc":"0,40 %"},{"name":"10 kHz do 30 kHz","range":"od 2 mV do 10 mV","cmc":"0,80 %"},{"name":"30 kHz do 100 kHz","range":"od 2 mV do 10 mV","cmc":"1,7 %"},{"name":"10 Hz do 100 Hz","range":"od 10 mV do 20 mV","cmc":"0,080 %"},{"name":"100 Hz do 2 kHz","range":"od 10 mV do 20 mV","cmc":"0,065 %"},{"name":"2 kHz do 10 kHz","range":"od 10 mV do 20 mV","cmc":"0,080 %"},{"name":"10 kHz do 30 kHz","range":"od 10 mV do 20 mV","cmc":"0,14 %"},{"name":"30 kHz do 100 kHz","range":"od 10 mV do 20 mV","cmc":"0,32 %"},{"name":"10 Hz do 100 Hz","range":"od 20 mV do 50 mV","cmc":"0,050 %"},{"name":"100 Hz do 2 kHz","range":"od 20 mV do 50 mV","cmc":"0,045 %"},{"name":"2 kHz do 10 kHz","range":"od 20 mV do 50 mV","cmc":"0,050 %"},{"name":"10 kHz do 30 kHz","range":"od 20 mV do 50 mV","cmc":"0,090 %"},{"name":"30 kHz do 100 kHz","range":"od 20 mV do 50 mV","cmc":"0,20 %"},{"name":"10 Hz do 100 Hz","range":"od 50 mV do 100 mV","cmc":"0,035 %"},{"name":"100 Hz do 10 kHz","range":"od 50 mV do 100 mV","cmc":"0,030 %"},{"name":"10k Hz do 30 kHz","range":"od 50 mV do 100 mV","cmc":"0,060 %"},{"name":"30 kHz do 100 kHz","range":"od 50 mV do 100 mV","cmc":"0,13 %"},{"name":"10 Hz do 100 Hz","range":"od 100 mV do 190 mV","cmc":"0,030 %"},{"name":"100 Hz do 10 kHz","range":"od 100 mV do 190 mV","cmc":"0,025 %"},{"name":"10 kHz do 30 kHz","range":"od 100 mV do 190 mV","cmc":"0,050 %"},{"name":"30 kHz do 100 kHz","range":"od 100 mV do 190 mV","cmc":"0,11 %"},{"name":"10 Hz do 40 Hz","range":"od 190 mV do 500 mV","cmc":"0,026 %"},{"name":"40 Hz do 100 Hz","range":"od 190 mV do 500 mV","cmc":"0,023 %"},{"name":"100 Hz do 2 kHz","range":"od 190 mV do 500 mV","cmc":"0,020 %"},{"name":"2 kHz do 10 kHz","range":"od 190 mV do 500 mV","cmc":"0,022 %"},{"name":"10 kHz do 30 kHz","range":"od 190 mV do 500 mV","cmc":"0,047 %"},{"name":"30 kHz do 100 kHz","range":"od 190 mV do 500 mV","cmc":"0,17 %"},{"name":"100 kHz do 300 kHz","range":"od 190 mV do 500 mV","cmc":"1,4 %"},{"name":"10 Hz do 40 Hz","range":"od 500 mV do 1 V","cmc":"0,019 %"},{"name":"40 Hz do 100 Hz","range":"od 500 mV do 1 V","cmc":"0,015 %"},{"name":"100 Hz do 2 kHz","range":"od 500 mV do 1 V","cmc":"0,013 %"},{"name":"2 kHz do 10 kHz","range":"od 500 mV do 1 V","cmc":"0,014 %"},{"name":"10 kHz do 30 kHz","range":"od 500 mV do 1 V","cmc":"0,030 %"},{"name":"30 kHz do 100 kHz","range":"od 500 mV do 1 V","cmc":"0,10 %"},{"name":"100 kHz do 300 kHz","range":"od 500 mV do 1 V","cmc":"0,75 %"},{"name":"10 Hz do 40 Hz","range":"od 1 V do 1,9 V","cmc":"0,016 %"},{"name":"40 Hz do 100 Hz","range":"od 1 V do 1,9 V","cmc":"0,013 %"},{"name":"100 Hz do 2 kHz","range":"od 1 V do 1,9 V","cmc":"0,010 %"},{"name":"2 kHz do 10 kHz","range":"od 1 V do 1,9 V","cmc":"0,012 %"},{"name":"10 kHz do 30 kHz","range":"od 1 V do 1,9 V","cmc":"0,026 %"},{"name":"30 kHz do 100 kHz","range":"od 1 V do 1,9 V","cmc":"0,082 %"},{"name":"100 kHz do 300 kHz","range":"od 1 V do 1,9 V","cmc":"0,55 %"},{"name":"10 Hz do 40 Hz","range":"od 1,9 V do 5 V","cmc":"0,026 %"},{"name":"40 Hz do 100 Hz","range":"od 1,9 V do 5 V","cmc":"0,022 %"},{"name":"100 Hz do 2 kHz","range":"od 1,9 V do 5 V","cmc":"0,019 %"},{"name":"2 kHz do 10 kHz","range":"od 1,9 V do 5 V","cmc":"0,022 %"},{"name":"10 kHz do 30 kHz","range":"od 1,9 V do 5 V","cmc":"0,045 %"},{"name":"30 kHz do 100 kHz","range":"od 1,9 V do 5 V","cmc":"0,17 %"},{"name":"100 kHz do 300 kHz","range":"od 1,9 V do 5 V","cmc":"1,4 %"},{"name":"10 Hz do 40 Hz","range":"od 5 V do 10 V","cmc":"0,018 %"},{"name":"40 Hz do 100 Hz","range":"od 5 V do 10 V","cmc":"0,015 %"},{"name":"100 Hz do 2 kHz","range":"od 5 V do 10 V","cmc":"0,013 %"},{"name":"2 kHz do 10 kHz","range":"od 5 V do 10 V","cmc":"0,017 %"},{"name":"10 kHz do 30 kHz","range":"od 5 V do 10 V","cmc":"0,032 %"},{"name":"30 kHz do 100 kHz","range":"od 5 V do 10 V","cmc":"0,11 %"},{"name":"100 kHz do 300 kHz","range":"od 5 V do 10 V","cmc":"0,80 %"},{"name":"10 Hz do 40 Hz","range":"od 10 V do 19 V","cmc":"0,016 %"},{"name":"40 Hz do 100 Hz","range":"od 10 V do 19 V","cmc":"0,013 %"},{"name":"100 Hz do 2 kHz","range":"od 10 V do 19 V","cmc":"0,010 %"},{"name":"2 kHz do 10 kHz","range":"od 10 V do 19 V","cmc":"0,013 %"},{"name":"10 kHz do 30 kHz","range":"od 10 V do 19 V","cmc":"0,027 %"},{"name":"30 kHz do 100 kHz","range":"od 10 V do 19 V","cmc":"0,080 %"},{"name":"100 kHz do 300 kHz","range":"od 10 V do 19 V","cmc":"0,55 %"},{"name":"10 Hz do 40 Hz","range":"od 19 V do 50 V","cmc":"0,026 %"},{"name":"40 Hz do 100 Hz","range":"od 19 V do 50 V","cmc":"0,022 %"},{"name":"100 Hz do 2 kHz","range":"od 19 V do 50 V","cmc":"0,020 %"},{"name":"2 kHz do 10 kHz","range":"od 19 V do 50 V","cmc":"0,021 %"},{"name":"10 kHz do 30 kHz","range":"od 19 V do 50 V","cmc":"0,045 %"},{"name":"30 kHz do 100 kHz","range":"od 19 V do 50 V","cmc":"0,16 %"},{"name":"10 Hz do 40 Hz","range":"od 50 V do 100 V","cmc":"0,019 %"},{"name":"40 Hz do 100 Hz","range":"od 50 V do 100 V","cmc":"0,015 %"},{"name":"100 Hz do 2 kHz","range":"od 50 V do 100 V","cmc":"0,013 %"},{"name":"2 kHz do 10 kHz","range":"od 50 V do 100 V","cmc":"0,015 %"},{"name":"10 kHz do 30 kHz","range":"od 50 V do 100 V","cmc":"0,031 %"},{"name":"30 kHz do 100 kHz","range":"od 50 V do 100 V","cmc":"0,11 %"},{"name":"10 Hz do 40 Hz","range":"od 100 V do 190 V","cmc":"0,017 %"},{"name":"40 Hz do 100 Hz","range":"od 100 V do 190 V","cmc":"0,013 %"},{"name":"100 Hz do 2 kHz","range":"od 100 V do 190 V","cmc":"0,011 %"},{"name":"2 kHz do 10 kHz","range":"od 100 V do 190 V","cmc":"0,012 %"},{"name":"10 kHz do 30 kHz","range":"od 100 V do 190 V","cmc":"0,026 %"},{"name":"30 kHz do 100 kHz","range":"od 100 V do 190 V","cmc":"0,078 %"},{"name":"40 Hz do 10 kHz","range":"od 190 V do 500 V","cmc":"0,032 %"},{"name":"10 kHz do 30 kHz","range":"od 190 V do 500 V","cmc":"0,070 %"},{"name":"40 Hz do 10 kHz","range":"500 V","cmc":"0,023 %"},{"name":"10 kHz do 30 kHz","range":"500 V","cmc":"0,055 %"},{"name":"40 Hz do 10 kHz","range":"od 500 V do 1000 V","cmc":"0,040 %"},{"name":"10 kHz do 30 kHz","range":"od 500 V do 1000 V","cmc":"0,16 %"}],"parameters_en":[{"name":"10 Hz to 10 kHz","range":"2 mV to 10 mV","cmc":"0,40 %"},{"name":"10 kHz to 30 kHz","range":"2 mV to 10 mV","cmc":"0,80 %"},{"name":"30 kHz to 100 kHz","range":"2 mV to 10 mV","cmc":"1,7 %"},{"name":"10 Hz to 100 Hz","range":"10 mV to 20 mV","cmc":"0,080 %"},{"name":"100 Hz to 2 kHz","range":"10 mV to 20 mV","cmc":"0,065 %"},{"name":"2 kHz to 10 kHz","range":"10 mV to 20 mV","cmc":"0,080 %"},{"name":"10 kHz to 30 kHz","range":"10 mV to 20 mV","cmc":"0,14 %"},{"name":"30 kHz to 100 kHz","range":"10 mV to 20 mV","cmc":"0,32 %"},{"name":"10 Hz to 100 Hz","range":"20 mV to 50 mV","cmc":"0,050 %"},{"name":"100 Hz to 2 kHz","range":"20 mV to 50 mV","cmc":"0,045 %"},{"name":"2 kHz to 10 kHz","range":"20 mV to 50 mV","cmc":"0,050 %"},{"name":"10 kHz to 30 kHz","range":"20 mV to 50 mV","cmc":"0,090 %"},{"name":"30 kHz to 100 kHz","range":"20 mV to 50 mV","cmc":"0,20 %"},{"name":"10 Hz to 100 Hz","range":"50 mV to 100 mV","cmc":"0,035 %"},{"name":"100 Hz to 10 kHz","range":"50 mV to 100 mV","cmc":"0,030 %"},{"name":"10k Hz to 30 kHz","range":"50 mV to 100 mV","cmc":"0,060 %"},{"name":"30 kHz to 100 kHz","range":"50 mV to 100 mV","cmc":"0,13 %"},{"name":"10 Hz to 100 Hz","range":"100 mV to 190 mV","cmc":"0,030 %"},{"name":"100 Hz to 10 kHz","range":"100 mV to 190 mV","cmc":"0,025 %"},{"name":"10 kHz to 30 kHz","range":"100 mV to 190 mV","cmc":"0,050 %"},{"name":"30 kHz to 100 kHz","range":"100 mV to 190 mV","cmc":"0,11 %"},{"name":"10 Hz to 40 Hz","range":"190 mV to 500 mV","cmc":"0,026 %"},{"name":"40 Hz to 100 Hz","range":"190 mV to 500 mV","cmc":"0,023 %"},{"name":"100 Hz to 2 kHz","range":"190 mV to 500 mV","cmc":"0,020 %"},{"name":"2 kHz to 10 kHz","range":"190 mV to 500 mV","cmc":"0,022 %"},{"name":"10 kHz to 30 kHz","range":"190 mV to 500 mV","cmc":"0,047 %"},{"name":"30 kHz to 100 kHz","range":"190 mV to 500 mV","cmc":"0,17 %"},{"name":"100 kHz to 300 kHz","range":"190 mV to 500 mV","cmc":"1,4 %"},{"name":"10 Hz to 40 Hz","range":"500 mV to 1 V","cmc":"0,019 %"},{"name":"40 Hz to 100 Hz","range":"500 mV to 1 V","cmc":"0,015 %"},{"name":"100 Hz to 2 kHz","range":"500 mV to 1 V","cmc":"0,013 %"},{"name":"2 kHz to 10 kHz","range":"500 mV to 1 V","cmc":"0,014 %"},{"name":"10 kHz to 30 kHz","range":"500 mV to 1 V","cmc":"0,030 %"},{"name":"30 kHz to 100 kHz","range":"500 mV to 1 V","cmc":"0,10 %"},{"name":"100 kHz to 300 kHz","range":"500 mV to 1 V","cmc":"0,75 %"},{"name":"10 Hz to 40 Hz","range":"1 V to 1,9 V","cmc":"0,016 %"},{"name":"40 Hz to 100 Hz","range":"1 V to 1,9 V","cmc":"0,013 %"},{"name":"100 Hz to 2 kHz","range":"1 V to 1,9 V","cmc":"0,010 %"},{"name":"2 kHz to 10 kHz","range":"1 V to 1,9 V","cmc":"0,012 %"},{"name":"10 kHz to 30 kHz","range":"1 V to 1,9 V","cmc":"0,026 %"},{"name":"30 kHz to 100 kHz","range":"1 V to 1,9 V","cmc":"0,082 %"},{"name":"100 kHz to 300 kHz","range":"1 V to 1,9 V","cmc":"0,55 %"},{"name":"10 Hz to 40 Hz","range":"1,9 V to 5 V","cmc":"0,026 %"},{"name":"40 Hz to 100 Hz","range":"1,9 V to 5 V","cmc":"0,022 %"},{"name":"100 Hz to 2 kHz","range":"1,9 V to 5 V","cmc":"0,019 %"},{"name":"2 kHz to 10 kHz","range":"1,9 V to 5 V","cmc":"0,022 %"},{"name":"10 kHz to 30 kHz","range":"1,9 V to 5 V","cmc":"0,045 %"},{"name":"30 kHz to 100 kHz","range":"1,9 V to 5 V","cmc":"0,17 %"},{"name":"100 kHz to 300 kHz","range":"1,9 V to 5 V","cmc":"1,4 %"},{"name":"10 Hz to 40 Hz","range":"5 V to 10 V","cmc":"0,018 %"},{"name":"40 Hz to 100 Hz","range":"5 V to 10 V","cmc":"0,015 %"},{"name":"100 Hz to 2 kHz","range":"5 V to 10 V","cmc":"0,013 %"},{"name":"2 kHz to 10 kHz","range":"5 V to 10 V","cmc":"0,017 %"},{"name":"10 kHz to 30 kHz","range":"5 V to 10 V","cmc":"0,032 %"},{"name":"30 kHz to 100 kHz","range":"5 V to 10 V","cmc":"0,11 %"},{"name":"100 kHz to 300 kHz","range":"5 V to 10 V","cmc":"0,80 %"},{"name":"10 Hz to 40 Hz","range":"10 V to 19 V","cmc":"0,016 %"},{"name":"40 Hz to 100 Hz","range":"10 V to 19 V","cmc":"0,013 %"},{"name":"100 Hz to 2 kHz","range":"10 V to 19 V","cmc":"0,010 %"},{"name":"2 kHz to 10 kHz","range":"10 V to 19 V","cmc":"0,013 %"},{"name":"10 kHz to 30 kHz","range":"10 V to 19 V","cmc":"0,027 %"},{"name":"30 kHz to 100 kHz","range":"10 V to 19 V","cmc":"0,080 %"},{"name":"100 kHz to 300 kHz","range":"10 V to 19 V","cmc":"0,55 %"},{"name":"10 Hz to 40 Hz","range":"19 V to 50 V","cmc":"0,026 %"},{"name":"40 Hz to 100 Hz","range":"19 V to 50 V","cmc":"0,022 %"},{"name":"100 Hz to 2 kHz","range":"19 V to 50 V","cmc":"0,020 %"},{"name":"2 kHz to 10 kHz","range":"19 V to 50 V","cmc":"0,021 %"},{"name":"10 kHz to 30 kHz","range":"19 V to 50 V","cmc":"0,045 %"},{"name":"30 kHz to 100 kHz","range":"19 V to 50 V","cmc":"0,16 %"},{"name":"10 Hz to 40 Hz","range":"50 V to 100 V","cmc":"0,019 %"},{"name":"40 Hz to 100 Hz","range":"50 V to 100 V","cmc":"0,015 %"},{"name":"100 Hz to 2 kHz","range":"50 V to 100 V","cmc":"0,013 %"},{"name":"2 kHz to 10 kHz","range":"50 V to 100 V","cmc":"0,015 %"},{"name":"10 kHz to 30 kHz","range":"50 V to 100 V","cmc":"0,031 %"},{"name":"30 kHz to 100 kHz","range":"50 V to 100 V","cmc":"0,11 %"},{"name":"10 Hz to 40 Hz","range":"100 V to 190 V","cmc":"0,017 %"},{"name":"40 Hz to 100 Hz","range":"100 V to 190 V","cmc":"0,013 %"},{"name":"100 Hz to 2 kHz","range":"100 V to 190 V","cmc":"0,011 %"},{"name":"2 kHz to 10 kHz","range":"100 V to 190 V","cmc":"0,012 %"},{"name":"10 kHz to 30 kHz","range":"100 V to 190 V","cmc":"0,026 %"},{"name":"30 kHz to 100 kHz","range":"100 V to 190 V","cmc":"0,078 %"},{"name":"40 Hz to 10 kHz","range":"190 V to 500 V","cmc":"0,032 %"},{"name":"10 kHz to 30 kHz","range":"190 V to 500 V","cmc":"0,070 %"},{"name":"40 Hz to 10 kHz","range":"500 V","cmc":"0,023 %"},{"name":"10 kHz to 30 kHz","range":"500 V","cmc":"0,055 %"},{"name":"40 Hz to 10 kHz","range":"500 V to 1000 V","cmc":"0,040 %"},{"name":"10 kHz to 30 kHz","range":"500 V to 1000 V","cmc":"0,16 %"}],"parameters_zh":[{"name":"10 Hz 至 10 kHz","range":"2 mV 至 10 mV","cmc":"0,40 %"},{"name":"10 kHz 至 30 kHz","range":"2 mV 至 10 mV","cmc":"0,80 %"},{"name":"30 kHz 至 100 kHz","range":"2 mV 至 10 mV","cmc":"1,7 %"},{"name":"10 Hz 至 100 Hz","range":"10 mV 至 20 mV","cmc":"0,080 %"},{"name":"100 Hz 至 2 kHz","range":"10 mV 至 20 mV","cmc":"0,065 %"},{"name":"2 kHz 至 10 kHz","range":"10 mV 至 20 mV","cmc":"0,080 %"},{"name":"10 kHz 至 30 kHz","range":"10 mV 至 20 mV","cmc":"0,14 %"},{"name":"30 kHz 至 100 kHz","range":"10 mV 至 20 mV","cmc":"0,32 %"},{"name":"10 Hz 至 100 Hz","range":"20 mV 至 50 mV","cmc":"0,050 %"},{"name":"100 Hz 至 2 kHz","range":"20 mV 至 50 mV","cmc":"0,045 %"},{"name":"2 kHz 至 10 kHz","range":"20 mV 至 50 mV","cmc":"0,050 %"},{"name":"10 kHz 至 30 kHz","range":"20 mV 至 50 mV","cmc":"0,090 %"},{"name":"30 kHz 至 100 kHz","range":"20 mV 至 50 mV","cmc":"0,20 %"},{"name":"10 Hz 至 100 Hz","range":"50 mV 至 100 mV","cmc":"0,035 %"},{"name":"100 Hz 至 10 kHz","range":"50 mV 至 100 mV","cmc":"0,030 %"},{"name":"10k Hz 至 30 kHz","range":"50 mV 至 100 mV","cmc":"0,060 %"},{"name":"30 kHz 至 100 kHz","range":"50 mV 至 100 mV","cmc":"0,13 %"},{"name":"10 Hz 至 100 Hz","range":"100 mV 至 190 mV","cmc":"0,030 %"},{"name":"100 Hz 至 10 kHz","range":"100 mV 至 190 mV","cmc":"0,025 %"},{"name":"10 kHz 至 30 kHz","range":"100 mV 至 190 mV","cmc":"0,050 %"},{"name":"30 kHz 至 100 kHz","range":"100 mV 至 190 mV","cmc":"0,11 %"},{"name":"10 Hz 至 40 Hz","range":"190 mV 至 500 mV","cmc":"0,026 %"},{"name":"40 Hz 至 100 Hz","range":"190 mV 至 500 mV","cmc":"0,023 %"},{"name":"100 Hz 至 2 kHz","range":"190 mV 至 500 mV","cmc":"0,020 %"},{"name":"2 kHz 至 10 kHz","range":"190 mV 至 500 mV","cmc":"0,022 %"},{"name":"10 kHz 至 30 kHz","range":"190 mV 至 500 mV","cmc":"0,047 %"},{"name":"30 kHz 至 100 kHz","range":"190 mV 至 500 mV","cmc":"0,17 %"},{"name":"100 kHz 至 300 kHz","range":"190 mV 至 500 mV","cmc":"1,4 %"},{"name":"10 Hz 至 40 Hz","range":"500 mV 至 1 V","cmc":"0,019 %"},{"name":"40 Hz 至 100 Hz","range":"500 mV 至 1 V","cmc":"0,015 %"},{"name":"100 Hz 至 2 kHz","range":"500 mV 至 1 V","cmc":"0,013 %"},{"name":"2 kHz 至 10 kHz","range":"500 mV 至 1 V","cmc":"0,014 %"},{"name":"10 kHz 至 30 kHz","range":"500 mV 至 1 V","cmc":"0,030 %"},{"name":"30 kHz 至 100 kHz","range":"500 mV 至 1 V","cmc":"0,10 %"},{"name":"100 kHz 至 300 kHz","range":"500 mV 至 1 V","cmc":"0,75 %"},{"name":"10 Hz 至 40 Hz","range":"1 V 至 1,9 V","cmc":"0,016 %"},{"name":"40 Hz 至 100 Hz","range":"1 V 至 1,9 V","cmc":"0,013 %"},{"name":"100 Hz 至 2 kHz","range":"1 V 至 1,9 V","cmc":"0,010 %"},{"name":"2 kHz 至 10 kHz","range":"1 V 至 1,9 V","cmc":"0,012 %"},{"name":"10 kHz 至 30 kHz","range":"1 V 至 1,9 V","cmc":"0,026 %"},{"name":"30 kHz 至 100 kHz","range":"1 V 至 1,9 V","cmc":"0,082 %"},{"name":"100 kHz 至 300 kHz","range":"1 V 至 1,9 V","cmc":"0,55 %"},{"name":"10 Hz 至 40 Hz","range":"1,9 V 至 5 V","cmc":"0,026 %"},{"name":"40 Hz 至 100 Hz","range":"1,9 V 至 5 V","cmc":"0,022 %"},{"name":"100 Hz 至 2 kHz","range":"1,9 V 至 5 V","cmc":"0,019 %"},{"name":"2 kHz 至 10 kHz","range":"1,9 V 至 5 V","cmc":"0,022 %"},{"name":"10 kHz 至 30 kHz","range":"1,9 V 至 5 V","cmc":"0,045 %"},{"name":"30 kHz 至 100 kHz","range":"1,9 V 至 5 V","cmc":"0,17 %"},{"name":"100 kHz 至 300 kHz","range":"1,9 V 至 5 V","cmc":"1,4 %"},{"name":"10 Hz 至 40 Hz","range":"5 V 至 10 V","cmc":"0,018 %"},{"name":"40 Hz 至 100 Hz","range":"5 V 至 10 V","cmc":"0,015 %"},{"name":"100 Hz 至 2 kHz","range":"5 V 至 10 V","cmc":"0,013 %"},{"name":"2 kHz 至 10 kHz","range":"5 V 至 10 V","cmc":"0,017 %"},{"name":"10 kHz 至 30 kHz","range":"5 V 至 10 V","cmc":"0,032 %"},{"name":"30 kHz 至 100 kHz","range":"5 V 至 10 V","cmc":"0,11 %"},{"name":"100 kHz 至 300 kHz","range":"5 V 至 10 V","cmc":"0,80 %"},{"name":"10 Hz 至 40 Hz","range":"10 V 至 19 V","cmc":"0,016 %"},{"name":"40 Hz 至 100 Hz","range":"10 V 至 19 V","cmc":"0,013 %"},{"name":"100 Hz 至 2 kHz","range":"10 V 至 19 V","cmc":"0,010 %"},{"name":"2 kHz 至 10 kHz","range":"10 V 至 19 V","cmc":"0,013 %"},{"name":"10 kHz 至 30 kHz","range":"10 V 至 19 V","cmc":"0,027 %"},{"name":"30 kHz 至 100 kHz","range":"10 V 至 19 V","cmc":"0,080 %"},{"name":"100 kHz 至 300 kHz","range":"10 V 至 19 V","cmc":"0,55 %"},{"name":"10 Hz 至 40 Hz","range":"19 V 至 50 V","cmc":"0,026 %"},{"name":"40 Hz 至 100 Hz","range":"19 V 至 50 V","cmc":"0,022 %"},{"name":"100 Hz 至 2 kHz","range":"19 V 至 50 V","cmc":"0,020 %"},{"name":"2 kHz 至 10 kHz","range":"19 V 至 50 V","cmc":"0,021 %"},{"name":"10 kHz 至 30 kHz","range":"19 V 至 50 V","cmc":"0,045 %"},{"name":"30 kHz 至 100 kHz","range":"19 V 至 50 V","cmc":"0,16 %"},{"name":"10 Hz 至 40 Hz","range":"50 V 至 100 V","cmc":"0,019 %"},{"name":"40 Hz 至 100 Hz","range":"50 V 至 100 V","cmc":"0,015 %"},{"name":"100 Hz 至 2 kHz","range":"50 V 至 100 V","cmc":"0,013 %"},{"name":"2 kHz 至 10 kHz","range":"50 V 至 100 V","cmc":"0,015 %"},{"name":"10 kHz 至 30 kHz","range":"50 V 至 100 V","cmc":"0,031 %"},{"name":"30 kHz 至 100 kHz","range":"50 V 至 100 V","cmc":"0,11 %"},{"name":"10 Hz 至 40 Hz","range":"100 V 至 190 V","cmc":"0,017 %"},{"name":"40 Hz 至 100 Hz","range":"100 V 至 190 V","cmc":"0,013 %"},{"name":"100 Hz 至 2 kHz","range":"100 V 至 190 V","cmc":"0,011 %"},{"name":"2 kHz 至 10 kHz","range":"100 V 至 190 V","cmc":"0,012 %"},{"name":"10 kHz 至 30 kHz","range":"100 V 至 190 V","cmc":"0,026 %"},{"name":"30 kHz 至 100 kHz","range":"100 V 至 190 V","cmc":"0,078 %"},{"name":"40 Hz 至 10 kHz","range":"190 V 至 500 V","cmc":"0,032 %"},{"name":"10 kHz 至 30 kHz","range":"190 V 至 500 V","cmc":"0,070 %"},{"name":"40 Hz 至 10 kHz","range":"500 V","cmc":"0,023 %"},{"name":"10 kHz 至 30 kHz","range":"500 V","cmc":"0,055 %"},{"name":"40 Hz 至 10 kHz","range":"500 V 至 1000 V","cmc":"0,040 %"},{"name":"10 kHz 至 30 kHz","range":"500 V 至 1000 V","cmc":"0,16 %"}],"parameters_cs":[{"name":"10 Hz až 10 kHz","range":"2 mV až 10 mV","cmc":"0,40 %"},{"name":"10 kHz až 30 kHz","range":"2 mV až 10 mV","cmc":"0,80 %"},{"name":"30 kHz až 100 kHz","range":"2 mV až 10 mV","cmc":"1,7 %"},{"name":"10 Hz až 100 Hz","range":"10 mV až 20 mV","cmc":"0,080 %"},{"name":"100 Hz až 2 kHz","range":"10 mV až 20 mV","cmc":"0,065 %"},{"name":"2 kHz až 10 kHz","range":"10 mV až 20 mV","cmc":"0,080 %"},{"name":"10 kHz až 30 kHz","range":"10 mV až 20 mV","cmc":"0,14 %"},{"name":"30 kHz až 100 kHz","range":"10 mV až 20 mV","cmc":"0,32 %"},{"name":"10 Hz až 100 Hz","range":"20 mV až 50 mV","cmc":"0,050 %"},{"name":"100 Hz až 2 kHz","range":"20 mV až 50 mV","cmc":"0,045 %"},{"name":"2 kHz až 10 kHz","range":"20 mV až 50 mV","cmc":"0,050 %"},{"name":"10 kHz až 30 kHz","range":"20 mV až 50 mV","cmc":"0,090 %"},{"name":"30 kHz až 100 kHz","range":"20 mV až 50 mV","cmc":"0,20 %"},{"name":"10 Hz až 100 Hz","range":"50 mV až 100 mV","cmc":"0,035 %"},{"name":"100 Hz až 10 kHz","range":"50 mV až 100 mV","cmc":"0,030 %"},{"name":"10k Hz až 30 kHz","range":"50 mV až 100 mV","cmc":"0,060 %"},{"name":"30 kHz až 100 kHz","range":"50 mV až 100 mV","cmc":"0,13 %"},{"name":"10 Hz až 100 Hz","range":"100 mV až 190 mV","cmc":"0,030 %"},{"name":"100 Hz až 10 kHz","range":"100 mV až 190 mV","cmc":"0,025 %"},{"name":"10 kHz až 30 kHz","range":"100 mV až 190 mV","cmc":"0,050 %"},{"name":"30 kHz až 100 kHz","range":"100 mV až 190 mV","cmc":"0,11 %"},{"name":"10 Hz až 40 Hz","range":"190 mV až 500 mV","cmc":"0,026 %"},{"name":"40 Hz až 100 Hz","range":"190 mV až 500 mV","cmc":"0,023 %"},{"name":"100 Hz až 2 kHz","range":"190 mV až 500 mV","cmc":"0,020 %"},{"name":"2 kHz až 10 kHz","range":"190 mV až 500 mV","cmc":"0,022 %"},{"name":"10 kHz až 30 kHz","range":"190 mV až 500 mV","cmc":"0,047 %"},{"name":"30 kHz až 100 kHz","range":"190 mV až 500 mV","cmc":"0,17 %"},{"name":"100 kHz až 300 kHz","range":"190 mV až 500 mV","cmc":"1,4 %"},{"name":"10 Hz až 40 Hz","range":"500 mV až 1 V","cmc":"0,019 %"},{"name":"40 Hz až 100 Hz","range":"500 mV až 1 V","cmc":"0,015 %"},{"name":"100 Hz až 2 kHz","range":"500 mV až 1 V","cmc":"0,013 %"},{"name":"2 kHz až 10 kHz","range":"500 mV až 1 V","cmc":"0,014 %"},{"name":"10 kHz až 30 kHz","range":"500 mV až 1 V","cmc":"0,030 %"},{"name":"30 kHz až 100 kHz","range":"500 mV až 1 V","cmc":"0,10 %"},{"name":"100 kHz až 300 kHz","range":"500 mV až 1 V","cmc":"0,75 %"},{"name":"10 Hz až 40 Hz","range":"1 V až 1,9 V","cmc":"0,016 %"},{"name":"40 Hz až 100 Hz","range":"1 V až 1,9 V","cmc":"0,013 %"},{"name":"100 Hz až 2 kHz","range":"1 V až 1,9 V","cmc":"0,010 %"},{"name":"2 kHz až 10 kHz","range":"1 V až 1,9 V","cmc":"0,012 %"},{"name":"10 kHz až 30 kHz","range":"1 V až 1,9 V","cmc":"0,026 %"},{"name":"30 kHz až 100 kHz","range":"1 V až 1,9 V","cmc":"0,082 %"},{"name":"100 kHz až 300 kHz","range":"1 V až 1,9 V","cmc":"0,55 %"},{"name":"10 Hz až 40 Hz","range":"1,9 V až 5 V","cmc":"0,026 %"},{"name":"40 Hz až 100 Hz","range":"1,9 V až 5 V","cmc":"0,022 %"},{"name":"100 Hz až 2 kHz","range":"1,9 V až 5 V","cmc":"0,019 %"},{"name":"2 kHz až 10 kHz","range":"1,9 V až 5 V","cmc":"0,022 %"},{"name":"10 kHz až 30 kHz","range":"1,9 V až 5 V","cmc":"0,045 %"},{"name":"30 kHz až 100 kHz","range":"1,9 V až 5 V","cmc":"0,17 %"},{"name":"100 kHz až 300 kHz","range":"1,9 V až 5 V","cmc":"1,4 %"},{"name":"10 Hz až 40 Hz","range":"5 V až 10 V","cmc":"0,018 %"},{"name":"40 Hz až 100 Hz","range":"5 V až 10 V","cmc":"0,015 %"},{"name":"100 Hz až 2 kHz","range":"5 V až 10 V","cmc":"0,013 %"},{"name":"2 kHz až 10 kHz","range":"5 V až 10 V","cmc":"0,017 %"},{"name":"10 kHz až 30 kHz","range":"5 V až 10 V","cmc":"0,032 %"},{"name":"30 kHz až 100 kHz","range":"5 V až 10 V","cmc":"0,11 %"},{"name":"100 kHz až 300 kHz","range":"5 V až 10 V","cmc":"0,80 %"},{"name":"10 Hz až 40 Hz","range":"10 V až 19 V","cmc":"0,016 %"},{"name":"40 Hz až 100 Hz","range":"10 V až 19 V","cmc":"0,013 %"},{"name":"100 Hz až 2 kHz","range":"10 V až 19 V","cmc":"0,010 %"},{"name":"2 kHz až 10 kHz","range":"10 V až 19 V","cmc":"0,013 %"},{"name":"10 kHz až 30 kHz","range":"10 V až 19 V","cmc":"0,027 %"},{"name":"30 kHz až 100 kHz","range":"10 V až 19 V","cmc":"0,080 %"},{"name":"100 kHz až 300 kHz","range":"10 V až 19 V","cmc":"0,55 %"},{"name":"10 Hz až 40 Hz","range":"19 V až 50 V","cmc":"0,026 %"},{"name":"40 Hz až 100 Hz","range":"19 V až 50 V","cmc":"0,022 %"},{"name":"100 Hz až 2 kHz","range":"19 V až 50 V","cmc":"0,020 %"},{"name":"2 kHz až 10 kHz","range":"19 V až 50 V","cmc":"0,021 %"},{"name":"10 kHz až 30 kHz","range":"19 V až 50 V","cmc":"0,045 %"},{"name":"30 kHz až 100 kHz","range":"19 V až 50 V","cmc":"0,16 %"},{"name":"10 Hz až 40 Hz","range":"50 V až 100 V","cmc":"0,019 %"},{"name":"40 Hz až 100 Hz","range":"50 V až 100 V","cmc":"0,015 %"},{"name":"100 Hz až 2 kHz","range":"50 V až 100 V","cmc":"0,013 %"},{"name":"2 kHz až 10 kHz","range":"50 V až 100 V","cmc":"0,015 %"},{"name":"10 kHz až 30 kHz","range":"50 V až 100 V","cmc":"0,031 %"},{"name":"30 kHz až 100 kHz","range":"50 V až 100 V","cmc":"0,11 %"},{"name":"10 Hz až 40 Hz","range":"100 V až 190 V","cmc":"0,017 %"},{"name":"40 Hz až 100 Hz","range":"100 V až 190 V","cmc":"0,013 %"},{"name":"100 Hz až 2 kHz","range":"100 V až 190 V","cmc":"0,011 %"},{"name":"2 kHz až 10 kHz","range":"100 V až 190 V","cmc":"0,012 %"},{"name":"10 kHz až 30 kHz","range":"100 V až 190 V","cmc":"0,026 %"},{"name":"30 kHz až 100 kHz","range":"100 V až 190 V","cmc":"0,078 %"},{"name":"40 Hz až 10 kHz","range":"190 V až 500 V","cmc":"0,032 %"},{"name":"10 kHz až 30 kHz","range":"190 V až 500 V","cmc":"0,070 %"},{"name":"40 Hz až 10 kHz","range":"500 V","cmc":"0,023 %"},{"name":"10 kHz až 30 kHz","range":"500 V","cmc":"0,055 %"},{"name":"40 Hz až 10 kHz","range":"500 V až 1000 V","cmc":"0,040 %"},{"name":"10 kHz až 30 kHz","range":"500 V až 1000 V","cmc":"0,16 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 10 kHz od 2 mV do 10 mV CMC 0,40 %\n10 kHz do 30 kHz od 2 mV do 10 mV CMC 0,80 %\n30 kHz do 100 kHz od 2 mV do 10 mV CMC 1,7 %\n10 Hz do 100 Hz od 10 mV do 20 mV CMC 0,080 %\n100 Hz do 2 kHz od 10 mV do 20 mV CMC 0,065 %\n2 kHz do 10 kHz od 10 mV do 20 mV CMC 0,080 %\n10 kHz do 30 kHz od 10 mV do 20 mV CMC 0,14 %\n30 kHz do 100 kHz od 10 mV do 20 mV CMC 0,32 %\n10 Hz do 100 Hz od 20 mV do 50 mV CMC 0,050 %\n100 Hz do 2 kHz od 20 mV do 50 mV CMC 0,045 %\n2 kHz do 10 kHz od 20 mV do 50 mV CMC 0,050 %\n10 kHz do 30 kHz od 20 mV do 50 mV CMC 0,090 %\n30 kHz do 100 kHz od 20 mV do 50 mV CMC 0,20 %\n10 Hz do 100 Hz od 50 mV do 100 mV CMC 0,035 %\n100 Hz do 10 kHz od 50 mV do 100 mV CMC 0,030 %\n10k Hz do 30 kHz od 50 mV do 100 mV CMC 0,060 %\n30 kHz do 100 kHz od 50 mV do 100 mV CMC 0,13 %\n10 Hz do 100 Hz od 100 mV do 190 mV CMC 0,030 %\n100 Hz do 10 kHz od 100 mV do 190 mV CMC 0,025 %\n10 kHz do 30 kHz od 100 mV do 190 mV CMC 0,050 %\n30 kHz do 100 kHz od 100 mV do 190 mV CMC 0,11 %\n10 Hz do 40 Hz od 190 mV do 500 mV CMC 0,026 %\n40 Hz do 100 Hz od 190 mV do 500 mV CMC 0,023 %\n100 Hz do 2 kHz od 190 mV do 500 mV CMC 0,020 %\n2 kHz do 10 kHz od 190 mV do 500 mV CMC 0,022 %\n10 kHz do 30 kHz od 190 mV do 500 mV CMC 0,047 %\n30 kHz do 100 kHz od 190 mV do 500 mV CMC 0,17 %\n100 kHz do 300 kHz od 190 mV do 500 mV CMC 1,4 %\n10 Hz do 40 Hz od 500 mV do 1 V CMC 0,019 %\n40 Hz do 100 Hz od 500 mV do 1 V CMC 0,015 %\n100 Hz do 2 kHz od 500 mV do 1 V CMC 0,013 %\n2 kHz do 10 kHz od 500 mV do 1 V CMC 0,014 %\n10 kHz do 30 kHz od 500 mV do 1 V CMC 0,030 %\n30 kHz do 100 kHz od 500 mV do 1 V CMC 0,10 %\n100 kHz do 300 kHz od 500 mV do 1 V CMC 0,75 %\n10 Hz do 40 Hz od 1 V do 1,9 V CMC 0,016 %\n40 Hz do 100 Hz od 1 V do 1,9 V CMC 0,013 %\n100 Hz do 2 kHz od 1 V do 1,9 V CMC 0,010 %\n2 kHz do 10 kHz od 1 V do 1,9 V CMC 0,012 %\n10 kHz do 30 kHz od 1 V do 1,9 V CMC 0,026 %\n30 kHz do 100 kHz od 1 V do 1,9 V CMC 0,082 %\n100 kHz do 300 kHz od 1 V do 1,9 V CMC 0,55 %\n10 Hz do 40 Hz od 1,9 V do 5 V CMC 0,026 %\n40 Hz do 100 Hz od 1,9 V do 5 V CMC 0,022 %\n100 Hz do 2 kHz od 1,9 V do 5 V CMC 0,019 %\n2 kHz do 10 kHz od 1,9 V do 5 V CMC 0,022 %\n10 kHz do 30 kHz od 1,9 V do 5 V CMC 0,045 %\n30 kHz do 100 kHz od 1,9 V do 5 V CMC 0,17 %\n100 kHz do 300 kHz od 1,9 V do 5 V CMC 1,4 %\n10 Hz do 40 Hz od 5 V do 10 V CMC 0,018 %\n40 Hz do 100 Hz od 5 V do 10 V CMC 0,015 %\n100 Hz do 2 kHz od 5 V do 10 V CMC 0,013 %\n2 kHz do 10 kHz od 5 V do 10 V CMC 0,017 %\n10 kHz do 30 kHz od 5 V do 10 V CMC 0,032 %\n30 kHz do 100 kHz od 5 V do 10 V CMC 0,11 %\n100 kHz do 300 kHz od 5 V do 10 V CMC 0,80 %\n10 Hz do 40 Hz od 10 V do 19 V CMC 0,016 %\n40 Hz do 100 Hz od 10 V do 19 V CMC 0,013 %\n100 Hz do 2 kHz od 10 V do 19 V CMC 0,010 %\n2 kHz do 10 kHz od 10 V do 19 V CMC 0,013 %\n10 kHz do 30 kHz od 10 V do 19 V CMC 0,027 %\n30 kHz do 100 kHz od 10 V do 19 V CMC 0,080 %\n100 kHz do 300 kHz od 10 V do 19 V CMC 0,55 %\n10 Hz do 40 Hz od 19 V do 50 V CMC 0,026 %\n40 Hz do 100 Hz od 19 V do 50 V CMC 0,022 %\n100 Hz do 2 kHz od 19 V do 50 V CMC 0,020 %\n2 kHz do 10 kHz od 19 V do 50 V CMC 0,021 %\n10 kHz do 30 kHz od 19 V do 50 V CMC 0,045 %\n30 kHz do 100 kHz od 19 V do 50 V CMC 0,16 %\n10 Hz do 40 Hz od 50 V do 100 V CMC 0,019 %\n40 Hz do 100 Hz od 50 V do 100 V CMC 0,015 %\n100 Hz do 2 kHz od 50 V do 100 V CMC 0,013 %\n2 kHz do 10 kHz od 50 V do 100 V CMC 0,015 %\n10 kHz do 30 kHz od 50 V do 100 V CMC 0,031 %\n30 kHz do 100 kHz od 50 V do 100 V CMC 0,11 %\n10 Hz do 40 Hz od 100 V do 190 V CMC 0,017 %\n40 Hz do 100 Hz od 100 V do 190 V CMC 0,013 %\n100 Hz do 2 kHz od 100 V do 190 V CMC 0,011 %\n2 kHz do 10 kHz od 100 V do 190 V CMC 0,012 %\n10 kHz do 30 kHz od 100 V do 190 V CMC 0,026 %\n30 kHz do 100 kHz od 100 V do 190 V CMC 0,078 %\n40 Hz do 10 kHz od 190 V do 500 V CMC 0,032 %\n10 kHz do 30 kHz od 190 V do 500 V CMC 0,070 %\n40 Hz do 10 kHz 500 V CMC 0,023 %\n10 kHz do 30 kHz 500 V CMC 0,055 %\n40 Hz do 10 kHz od 500 V do 1000 V CMC 0,040 %\n10 kHz do 30 kHz od 500 V do 1000 V CMC 0,16 %\nPomiar bezpośredni multimetrem","reference":"MKE-UST.1, MKE-SRP.1","norm_bases":["MKE-UST.1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 10 Hz do 10 kHz od 2 mV do 10 mV CMC 0,40 % 10 kHz do 30 kHz od 2 mV do 10 mV CMC 0,80 % 30 kHz do 100 kHz od 2 mV do 10 mV CMC 1,7 % 10 Hz do 100 Hz od 10 mV do 20 mV CMC 0,080 % 100 Hz do 2 kHz od 10 mV do 20 mV CMC 0,065 % 2 kHz do 10 kHz od 10 mV do 20 mV CMC 0,080 % 10 kHz do 30 kHz od 10 mV do 20 mV CMC 0,14 % 30 kHz do 100 kHz od 10 mV do 20 mV CMC 0,32 % 10 Hz do 100 Hz od 20 mV do 50 mV CMC 0,050 % 100 Hz do 2 kHz od 20 mV do 50 mV CMC 0,045 % 2 kHz do 10 kHz od 20 mV do 50 mV CMC 0,050 % 10 kHz do 30 kHz od 20 mV do 50 mV CMC 0,090 % 30 kHz do 100 kHz od 20 mV do 50 mV CMC 0,20 % 10 Hz do 100 Hz od 50 mV do 100 mV CMC 0,035 % 100 Hz do 10 kHz od 50 mV do 100 mV CMC 0,030 % 10k Hz do 30 kHz od 50 mV do 100 mV CMC 0,060 % 30 kHz do 100 kHz od 50 mV do 100 mV CMC 0,13 % 10 Hz do 100 Hz od 100 mV do 190 mV CMC 0,030 % 100 Hz do 10 kHz od 100 mV do 190 mV CMC 0,025 % 10 kHz do 30 kHz od 100 mV do 190 mV CMC 0,050 % 30 kHz do 100 kHz od 100 mV do 190 mV CMC 0,11 % 10 Hz do 40 Hz od 190 mV do 500 mV CMC 0,026 % 40 Hz do 100 Hz od 190 mV do 500 mV CMC 0,023 % 100 Hz do 2 kHz od 190 mV do 500 mV CMC 0,020 % 2 kHz do 10 kHz od 190 mV do 500 mV CMC 0,022 % 10 kHz do 30 kHz od 190 mV do 500 mV CMC 0,047 % 30 kHz do 100 kHz od 190 mV do 500 mV CMC 0,17 % 100 kHz do 300 kHz od 190 mV do 500 mV CMC 1,4 % 10 Hz do 40 Hz od 500 mV do 1 V CMC 0,019 % 40 Hz do 100 Hz od 500 mV do 1 V CMC 0,015 % 100 Hz do 2 kHz od 500 mV do 1 V CMC 0,013 % 2 kHz do 10 kHz od 500 mV do 1 V CMC 0,014 % 10 kHz do 30 kHz od 500 mV do 1 V CMC 0,030 % 30 kHz do 100 kHz od 500 mV do 1 V CMC 0,10 % 100 kHz do 300 kHz od 500 mV do 1 V CMC 0,75 % 10 Hz do 40 Hz od 1 V do 1,9 V CMC 0,016 % 40 Hz do 100 Hz od 1 V do 1,9 V CMC 0,013 % 100 Hz do 2 kHz od 1 V do 1,9 V CMC 0,010 % 2 kHz do 10 kHz od 1 V do 1,9 V CMC 0,012 % 10 kHz do 30 kHz od 1 V do 1,9 V CMC 0,026 % 30 kHz do 100 kHz od 1 V do 1,9 V CMC 0,082 % 100 kHz do 300 kHz od 1 V do 1,9 V CMC 0,55 % 10 Hz do 40 Hz od 1,9 V do 5 V CMC 0,026 % 40 Hz do 100 Hz od 1,9 V do 5 V CMC 0,022 % 100 Hz do 2 kHz od 1,9 V do 5 V CMC 0,019 % 2 kHz do 10 kHz od 1,9 V do 5 V CMC 0,022 % 10 kHz do 30 kHz od 1,9 V do 5 V CMC 0,045 % 30 kHz do 100 kHz od 1,9 V do 5 V CMC 0,17 % 100 kHz do 300 kHz od 1,9 V do 5 V CMC 1,4 % 10 Hz do 40 Hz od 5 V do 10 V CMC 0,018 % 40 Hz do 100 Hz od 5 V do 10 V CMC 0,015 % 100 Hz do 2 kHz od 5 V do 10 V CMC 0,013 % 2 kHz do 10 kHz od 5 V do 10 V CMC 0,017 % 10 kHz do 30 kHz od 5 V do 10 V CMC 0,032 % 30 kHz do 100 kHz od 5 V do 10 V CMC 0,11 % 100 kHz do 300 kHz od 5 V do 10 V CMC 0,80 % 10 Hz do 40 Hz od 10 V do 19 V CMC 0,016 % 40 Hz do 100 Hz od 10 V do 19 V CMC 0,013 % 100 Hz do 2 kHz od 10 V do 19 V CMC 0,010 % 2 kHz do 10 kHz od 10 V do 19 V CMC 0,013 % 10 kHz do 30 kHz od 10 V do 19 V CMC 0,027 % 30 kHz do 100 kHz od 10 V do 19 V CMC 0,080 % 100 kHz do 300 kHz od 10 V do 19 V CMC 0,55 % 10 Hz do 40 Hz od 19 V do 50 V CMC 0,026 % 40 Hz do 100 Hz od 19 V do 50 V CMC 0,022 % 100 Hz do 2 kHz od 19 V do 50 V CMC 0,020 % 2 kHz do 10 kHz od 19 V do 50 V CMC 0,021 % 10 kHz do 30 kHz od 19 V do 50 V CMC 0,045 % 30 kHz do 100 kHz od 19 V do 50 V CMC 0,16 % 10 Hz do 40 Hz od 50 V do 100 V CMC 0,019 % 40 Hz do 100 Hz od 50 V do 100 V CMC 0,015 % 100 Hz do 2 kHz od 50 V do 100 V CMC 0,013 % 2 kHz do 10 kHz od 50 V do 100 V CMC 0,015 % 10 kHz do 30 kHz od 50 V do 100 V CMC 0,031 % 30 kHz do 100 kHz od 50 V do 100 V CMC 0,11 % 10 Hz do 40 Hz od 100 V do 190 V CMC 0,017 % 40 Hz do 100 Hz od 100 V do 190 V CMC 0,013 % 100 Hz do 2 kHz od 100 V do 190 V CMC 0,011 % 2 kHz do 10 kHz od 100 V do 190 V CMC 0,012 % 10 kHz do 30 kHz od 100 V do 190 V CMC 0,026 % 30 kHz do 100 kHz od 100 V do 190 V CMC 0,078 % 40 Hz do 10 kHz od 190 V do 500 V CMC 0,032 % 10 kHz do 30 kHz od 190 V do 500 V CMC 0,070 % 40 Hz do 10 kHz 500 V CMC 0,023 % 10 kHz do 30 kHz 500 V CMC 0,055 % 40 Hz do 10 kHz od 500 V do 1000 V CMC 0,040 % 10 kHz do 30 kHz od 500 V do 1000 V CMC 0,16 % Střídavé napětí / Zdroje, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé měření multimetrem 10 Hz až 10 kHz 2 mV až 10 mV CMC 0,40 % 10 kHz až 30 kHz 2 mV až 10 mV CMC 0,80 % 30 kHz až 100 kHz 2 mV až 10 mV CMC 1,7 % 10 Hz až 100 Hz 10 mV až 20 mV CMC 0,080 % 100 Hz až 2 kHz 10 mV až 20 mV CMC 0,065 % 2 kHz až 10 kHz 10 mV až 20 mV CMC 0,080 % 10 kHz až 30 kHz 10 mV až 20 mV CMC 0,14 % 30 kHz až 100 kHz 10 mV až 20 mV CMC 0,32 % 10 Hz až 100 Hz 20 mV až 50 mV CMC 0,050 % 100 Hz až 2 kHz 20 mV až 50 mV CMC 0,045 % 2 kHz až 10 kHz 20 mV až 50 mV CMC 0,050 % 10 kHz až 30 kHz 20 mV až 50 mV CMC 0,090 % 30 kHz až 100 kHz 20 mV až 50 mV CMC 0,20 % 10 Hz až 100 Hz 50 mV až 100 mV CMC 0,035 % 100 Hz až 10 kHz 50 mV až 100 mV CMC 0,030 % 10k Hz až 30 kHz 50 mV až 100 mV CMC 0,060 % 30 kHz až 100 kHz 50 mV až 100 mV CMC 0,13 % 10 Hz až 100 Hz 100 mV až 190 mV CMC 0,030 % 100 Hz až 10 kHz 100 mV až 190 mV CMC 0,025 % 10 kHz až 30 kHz 100 mV až 190 mV CMC 0,050 % 30 kHz až 100 kHz 100 mV až 190 mV CMC 0,11 % 10 Hz až 40 Hz 190 mV až 500 mV CMC 0,026 % 40 Hz až 100 Hz 190 mV až 500 mV CMC 0,023 % 100 Hz až 2 kHz 190 mV až 500 mV CMC 0,020 % 2 kHz až 10 kHz 190 mV až 500 mV CMC 0,022 % 10 kHz až 30 kHz 190 mV až 500 mV CMC 0,047 % 30 kHz až 100 kHz 190 mV až 500 mV CMC 0,17 % 100 kHz až 300 kHz 190 mV až 500 mV CMC 1,4 % 10 Hz až 40 Hz 500 mV až 1 V CMC 0,019 % 40 Hz až 100 Hz 500 mV až 1 V CMC 0,015 % 100 Hz až 2 kHz 500 mV až 1 V CMC 0,013 % 2 kHz až 10 kHz 500 mV až 1 V CMC 0,014 % 10 kHz až 30 kHz 500 mV až 1 V CMC 0,030 % 30 kHz až 100 kHz 500 mV až 1 V CMC 0,10 % 100 kHz až 300 kHz 500 mV až 1 V CMC 0,75 % 10 Hz až 40 Hz 1 V až 1,9 V CMC 0,016 % 40 Hz až 100 Hz 1 V až 1,9 V CMC 0,013 % 100 Hz až 2 kHz 1 V až 1,9 V CMC 0,010 % 2 kHz až 10 kHz 1 V až 1,9 V CMC 0,012 % 10 kHz až 30 kHz 1 V až 1,9 V CMC 0,026 % 30 kHz až 100 kHz 1 V až 1,9 V CMC 0,082 % 100 kHz až 300 kHz 1 V až 1,9 V CMC 0,55 % 10 Hz až 40 Hz 1,9 V až 5 V CMC 0,026 % 40 Hz až 100 Hz 1,9 V až 5 V CMC 0,022 % 100 Hz až 2 kHz 1,9 V až 5 V CMC 0,019 % 2 kHz až 10 kHz 1,9 V až 5 V CMC 0,022 % 10 kHz až 30 kHz 1,9 V až 5 V CMC 0,045 % 30 kHz až 100 kHz 1,9 V až 5 V CMC 0,17 % 100 kHz až 300 kHz 1,9 V až 5 V CMC 1,4 % 10 Hz až 40 Hz 5 V až 10 V CMC 0,018 % 40 Hz až 100 Hz 5 V až 10 V CMC 0,015 % 100 Hz až 2 kHz 5 V až 10 V CMC 0,013 % 2 kHz až 10 kHz 5 V až 10 V CMC 0,017 % 10 kHz až 30 kHz 5 V až 10 V CMC 0,032 % 30 kHz až 100 kHz 5 V až 10 V CMC 0,11 % 100 kHz až 300 kHz 5 V až 10 V CMC 0,80 % 10 Hz až 40 Hz 10 V až 19 V CMC 0,016 % 40 Hz až 100 Hz 10 V až 19 V CMC 0,013 % 100 Hz až 2 kHz 10 V až 19 V CMC 0,010 % 2 kHz až 10 kHz 10 V až 19 V CMC 0,013 % 10 kHz až 30 kHz 10 V až 19 V CMC 0,027 % 30 kHz až 100 kHz 10 V až 19 V CMC 0,080 % 100 kHz až 300 kHz 10 V až 19 V CMC 0,55 % 10 Hz až 40 Hz 19 V až 50 V CMC 0,026 % 40 Hz až 100 Hz 19 V až 50 V CMC 0,022 % 100 Hz až 2 kHz 19 V až 50 V CMC 0,020 % 2 kHz až 10 kHz 19 V až 50 V CMC 0,021 % 10 kHz až 30 kHz 19 V až 50 V CMC 0,045 % 30 kHz až 100 kHz 19 V až 50 V CMC 0,16 % 10 Hz až 40 Hz 50 V až 100 V CMC 0,019 % 40 Hz až 100 Hz 50 V až 100 V CMC 0,015 % 100 Hz až 2 kHz 50 V až 100 V CMC 0,013 % 2 kHz až 10 kHz 50 V až 100 V CMC 0,015 % 10 kHz až 30 kHz 50 V až 100 V CMC 0,031 % 30 kHz až 100 kHz 50 V až 100 V CMC 0,11 % 10 Hz až 40 Hz 100 V až 190 V CMC 0,017 % 40 Hz až 100 Hz 100 V až 190 V CMC 0,013 % 100 Hz až 2 kHz 100 V až 190 V CMC 0,011 % 2 kHz až 10 kHz 100 V až 190 V CMC 0,012 % 10 kHz až 30 kHz 100 V až 190 V CMC 0,026 % 30 kHz až 100 kHz 100 V až 190 V CMC 0,078 % 40 Hz až 10 kHz 190 V až 500 V CMC 0,032 % 10 kHz až 30 kHz 190 V až 500 V CMC 0,070 % 40 Hz až 10 kHz 500 V CMC 0,023 % 10 kHz až 30 kHz 500 V CMC 0,055 % 40 Hz až 10 kHz 500 V až 1000 V CMC 0,040 % 10 kHz až 30 kHz 500 V až 1000 V CMC 0,16 % MKE-UST.1, MKE-SRP.1 Napiecie przemienne / zasilacze, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 10 Hz do 10 kHz od 2 mV do 10 mV CMC 0,40 % 10 kHz do 30 kHz od 2 mV do 10 mV CMC 0,80 % 30 kHz do 100 kHz od 2 mV do 10 mV CMC 1,7 % 10 Hz do 100 Hz od 10 mV do 20 mV CMC 0,080 % 100 Hz do 2 kHz od 10 mV do 20 mV CMC 0,065 % 2 kHz do 10 kHz od 10 mV do 20 mV CMC 0,080 % 10 kHz do 30 kHz od 10 mV do 20 mV CMC 0,14 % 30 kHz do 100 kHz od 10 mV do 20 mV CMC 0,32 % 10 Hz do 100 Hz od 20 mV do 50 mV CMC 0,050 % 100 Hz do 2 kHz od 20 mV do 50 mV CMC 0,045 % 2 kHz do 10 kHz od 20 mV do 50 mV CMC 0,050 % 10 kHz do 30 kHz od 20 mV do 50 mV CMC 0,090 % 30 kHz do 100 kHz od 20 mV do 50 mV CMC 0,20 % 10 Hz do 100 Hz od 50 mV do 100 mV CMC 0,035 % 100 Hz do 10 kHz od 50 mV do 100 mV CMC 0,030 % 10k Hz do 30 kHz od 50 mV do 100 mV CMC 0,060 % 30 kHz do 100 kHz od 50 mV do 100 mV CMC 0,13 % 10 Hz do 100 Hz od 100 mV do 190 mV CMC 0,030 % 100 Hz do 10 kHz od 100 mV do 190 mV CMC 0,025 % 10 kHz do 30 kHz od 100 mV do 190 mV CMC 0,050 % 30 kHz do 100 kHz od 100 mV do 190 mV CMC 0,11 % 10 Hz do 40 Hz od 190 mV do 500 mV CMC 0,026 % 40 Hz do 100 Hz od 190 mV do 500 mV CMC 0,023 % 100 Hz do 2 kHz od 190 mV do 500 mV CMC 0,020 % 2 kHz do 10 kHz od 190 mV do 500 mV CMC 0,022 % 10 kHz do 30 kHz od 190 mV do 500 mV CMC 0,047 % 30 kHz do 100 kHz od 190 mV do 500 mV CMC 0,17 % 100 kHz do 300 kHz od 190 mV do 500 mV CMC 1,4 % 10 Hz do 40 Hz od 500 mV do 1 V CMC 0,019 % 40 Hz do 100 Hz od 500 mV do 1 V CMC 0,015 % 100 Hz do 2 kHz od 500 mV do 1 V CMC 0,013 % 2 kHz do 10 kHz od 500 mV do 1 V CMC 0,014 % 10 kHz do 30 kHz od 500 mV do 1 V CMC 0,030 % 30 kHz do 100 kHz od 500 mV do 1 V CMC 0,10 % 100 kHz do 300 kHz od 500 mV do 1 V CMC 0,75 % 10 Hz do 40 Hz od 1 V do 1,9 V CMC 0,016 % 40 Hz do 100 Hz od 1 V do 1,9 V CMC 0,013 % 100 Hz do 2 kHz od 1 V do 1,9 V CMC 0,010 % 2 kHz do 10 kHz od 1 V do 1,9 V CMC 0,012 % 10 kHz do 30 kHz od 1 V do 1,9 V CMC 0,026 % 30 kHz do 100 kHz od 1 V do 1,9 V CMC 0,082 % 100 kHz do 300 kHz od 1 V do 1,9 V CMC 0,55 % 10 Hz do 40 Hz od 1,9 V do 5 V CMC 0,026 % 40 Hz do 100 Hz od 1,9 V do 5 V CMC 0,022 % 100 Hz do 2 kHz od 1,9 V do 5 V CMC 0,019 % 2 kHz do 10 kHz od 1,9 V do 5 V CMC 0,022 % 10 kHz do 30 kHz od 1,9 V do 5 V CMC 0,045 % 30 kHz do 100 kHz od 1,9 V do 5 V CMC 0,17 % 100 kHz do 300 kHz od 1,9 V do 5 V CMC 1,4 % 10 Hz do 40 Hz od 5 V do 10 V CMC 0,018 % 40 Hz do 100 Hz od 5 V do 10 V CMC 0,015 % 100 Hz do 2 kHz od 5 V do 10 V CMC 0,013 % 2 kHz do 10 kHz od 5 V do 10 V CMC 0,017 % 10 kHz do 30 kHz od 5 V do 10 V CMC 0,032 % 30 kHz do 100 kHz od 5 V do 10 V CMC 0,11 % 100 kHz do 300 kHz od 5 V do 10 V CMC 0,80 % 10 Hz do 40 Hz od 10 V do 19 V CMC 0,016 % 40 Hz do 100 Hz od 10 V do 19 V CMC 0,013 % 100 Hz do 2 kHz od 10 V do 19 V CMC 0,010 % 2 kHz do 10 kHz od 10 V do 19 V CMC 0,013 % 10 kHz do 30 kHz od 10 V do 19 V CMC 0,027 % 30 kHz do 100 kHz od 10 V do 19 V CMC 0,080 % 100 kHz do 300 kHz od 10 V do 19 V CMC 0,55 % 10 Hz do 40 Hz od 19 V do 50 V CMC 0,026 % 40 Hz do 100 Hz od 19 V do 50 V CMC 0,022 % 100 Hz do 2 kHz od 19 V do 50 V CMC 0,020 % 2 kHz do 10 kHz od 19 V do 50 V CMC 0,021 % 10 kHz do 30 kHz od 19 V do 50 V CMC 0,045 % 30 kHz do 100 kHz od 19 V do 50 V CMC 0,16 % 10 Hz do 40 Hz od 50 V do 100 V CMC 0,019 % 40 Hz do 100 Hz od 50 V do 100 V CMC 0,015 % 100 Hz do 2 kHz od 50 V do 100 V CMC 0,013 % 2 kHz do 10 kHz od 50 V do 100 V CMC 0,015 % 10 kHz do 30 kHz od 50 V do 100 V CMC 0,031 % 30 kHz do 100 kHz od 50 V do 100 V CMC 0,11 % 10 Hz do 40 Hz od 100 V do 190 V CMC 0,017 % 40 Hz do 100 Hz od 100 V do 190 V CMC 0,013 % 100 Hz do 2 kHz od 100 V do 190 V CMC 0,011 % 2 kHz do 10 kHz od 100 V do 190 V CMC 0,012 % 10 kHz do 30 kHz od 100 V do 190 V CMC 0,026 % 30 kHz do 100 kHz od 100 V do 190 V CMC 0,078 % 40 Hz do 10 kHz od 190 V do 500 V CMC 0,032 % 10 kHz do 30 kHz od 190 V do 500 V CMC 0,070 % 40 Hz do 10 kHz 500 V CMC 0,023 % 10 kHz do 30 kHz 500 V CMC 0,055 % 40 Hz do 10 kHz od 500 V do 1000 V CMC 0,040 % 10 kHz do 30 kHz od 500 V do 1000 V CMC 0,16 % Stridave napeti / Zdroje, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime mereni multimetrem 10 Hz az 10 kHz 2 mV az 10 mV CMC 0,40 % 10 kHz az 30 kHz 2 mV az 10 mV CMC 0,80 % 30 kHz az 100 kHz 2 mV az 10 mV CMC 1,7 % 10 Hz az 100 Hz 10 mV az 20 mV CMC 0,080 % 100 Hz az 2 kHz 10 mV az 20 mV CMC 0,065 % 2 kHz az 10 kHz 10 mV az 20 mV CMC 0,080 % 10 kHz az 30 kHz 10 mV az 20 mV CMC 0,14 % 30 kHz az 100 kHz 10 mV az 20 mV CMC 0,32 % 10 Hz az 100 Hz 20 mV az 50 mV CMC 0,050 % 100 Hz az 2 kHz 20 mV az 50 mV CMC 0,045 % 2 kHz az 10 kHz 20 mV az 50 mV CMC 0,050 % 10 kHz az 30 kHz 20 mV az 50 mV CMC 0,090 % 30 kHz az 100 kHz 20 mV az 50 mV CMC 0,20 % 10 Hz az 100 Hz 50 mV az 100 mV CMC 0,035 % 100 Hz az 10 kHz 50 mV az 100 mV CMC 0,030 % 10k Hz az 30 kHz 50 mV az 100 mV CMC 0,060 % 30 kHz az 100 kHz 50 mV az 100 mV CMC 0,13 % 10 Hz az 100 Hz 100 mV az 190 mV CMC 0,030 % 100 Hz az 10 kHz 100 mV az 190 mV CMC 0,025 % 10 kHz az 30 kHz 100 mV az 190 mV CMC 0,050 % 30 kHz az 100 kHz 100 mV az 190 mV CMC 0,11 % 10 Hz az 40 Hz 190 mV az 500 mV CMC 0,026 % 40 Hz az 100 Hz 190 mV az 500 mV CMC 0,023 % 100 Hz az 2 kHz 190 mV az 500 mV CMC 0,020 % 2 kHz az 10 kHz 190 mV az 500 mV CMC 0,022 % 10 kHz az 30 kHz 190 mV az 500 mV CMC 0,047 % 30 kHz az 100 kHz 190 mV az 500 mV CMC 0,17 % 100 kHz az 300 kHz 190 mV az 500 mV CMC 1,4 % 10 Hz az 40 Hz 500 mV az 1 V CMC 0,019 % 40 Hz az 100 Hz 500 mV az 1 V CMC 0,015 % 100 Hz az 2 kHz 500 mV az 1 V CMC 0,013 % 2 kHz az 10 kHz 500 mV az 1 V CMC 0,014 % 10 kHz az 30 kHz 500 mV az 1 V CMC 0,030 % 30 kHz az 100 kHz 500 mV az 1 V CMC 0,10 % 100 kHz az 300 kHz 500 mV az 1 V CMC 0,75 % 10 Hz az 40 Hz 1 V az 1,9 V CMC 0,016 % 40 Hz az 100 Hz 1 V az 1,9 V CMC 0,013 % 100 Hz az 2 kHz 1 V az 1,9 V CMC 0,010 % 2 kHz az 10 kHz 1 V az 1,9 V CMC 0,012 % 10 kHz az 30 kHz 1 V az 1,9 V CMC 0,026 % 30 kHz az 100 kHz 1 V az 1,9 V CMC 0,082 % 100 kHz az 300 kHz 1 V az 1,9 V CMC 0,55 % 10 Hz az 40 Hz 1,9 V az 5 V CMC 0,026 % 40 Hz az 100 Hz 1,9 V az 5 V CMC 0,022 % 100 Hz az 2 kHz 1,9 V az 5 V CMC 0,019 % 2 kHz az 10 kHz 1,9 V az 5 V CMC 0,022 % 10 kHz az 30 kHz 1,9 V az 5 V CMC 0,045 % 30 kHz az 100 kHz 1,9 V az 5 V CMC 0,17 % 100 kHz az 300 kHz 1,9 V az 5 V CMC 1,4 % 10 Hz az 40 Hz 5 V az 10 V CMC 0,018 % 40 Hz az 100 Hz 5 V az 10 V CMC 0,015 % 100 Hz az 2 kHz 5 V az 10 V CMC 0,013 % 2 kHz az 10 kHz 5 V az 10 V CMC 0,017 % 10 kHz az 30 kHz 5 V az 10 V CMC 0,032 % 30 kHz az 100 kHz 5 V az 10 V CMC 0,11 % 100 kHz az 300 kHz 5 V az 10 V CMC 0,80 % 10 Hz az 40 Hz 10 V az 19 V CMC 0,016 % 40 Hz az 100 Hz 10 V az 19 V CMC 0,013 % 100 Hz az 2 kHz 10 V az 19 V CMC 0,010 % 2 kHz az 10 kHz 10 V az 19 V CMC 0,013 % 10 kHz az 30 kHz 10 V az 19 V CMC 0,027 % 30 kHz az 100 kHz 10 V az 19 V CMC 0,080 % 100 kHz az 300 kHz 10 V az 19 V CMC 0,55 % 10 Hz az 40 Hz 19 V az 50 V CMC 0,026 % 40 Hz az 100 Hz 19 V az 50 V CMC 0,022 % 100 Hz az 2 kHz 19 V az 50 V CMC 0,020 % 2 kHz az 10 kHz 19 V az 50 V CMC 0,021 % 10 kHz az 30 kHz 19 V az 50 V CMC 0,045 % 30 kHz az 100 kHz 19 V az 50 V CMC 0,16 % 10 Hz az 40 Hz 50 V az 100 V CMC 0,019 % 40 Hz az 100 Hz 50 V az 100 V CMC 0,015 % 100 Hz az 2 kHz 50 V az 100 V CMC 0,013 % 2 kHz az 10 kHz 50 V az 100 V CMC 0,015 % 10 kHz az 30 kHz 50 V az 100 V CMC 0,031 % 30 kHz az 100 kHz 50 V az 100 V CMC 0,11 % 10 Hz az 40 Hz 100 V az 190 V CMC 0,017 % 40 Hz az 100 Hz 100 V az 190 V CMC 0,013 % 100 Hz az 2 kHz 100 V az 190 V CMC 0,011 % 2 kHz az 10 kHz 100 V az 190 V CMC 0,012 % 10 kHz az 30 kHz 100 V az 190 V CMC 0,026 % 30 kHz az 100 kHz 100 V az 190 V CMC 0,078 % 40 Hz az 10 kHz 190 V az 500 V CMC 0,032 % 10 kHz az 30 kHz 190 V az 500 V CMC 0,070 % 40 Hz az 10 kHz 500 V CMC 0,023 % 10 kHz az 30 kHz 500 V CMC 0,055 % 40 Hz az 10 kHz 500 V az 1000 V CMC 0,040 % 10 kHz az 30 kHz 500 V az 1000 V CMC 0,16 % MKE-UST.1, MKE-SRP.1","search_en":"AC voltage / Power supplies, calibrators, inspection instruments Calibration – electrical quantities Direct measurement using a multimeter 10 Hz to 10 kHz 2 mV to 10 mV CMC 0,40 % 10 kHz to 30 kHz 2 mV to 10 mV CMC 0,80 % 30 kHz to 100 kHz 2 mV to 10 mV CMC 1,7 % 10 Hz to 100 Hz 10 mV to 20 mV CMC 0,080 % 100 Hz to 2 kHz 10 mV to 20 mV CMC 0,065 % 2 kHz to 10 kHz 10 mV to 20 mV CMC 0,080 % 10 kHz to 30 kHz 10 mV to 20 mV CMC 0,14 % 30 kHz to 100 kHz 10 mV to 20 mV CMC 0,32 % 10 Hz to 100 Hz 20 mV to 50 mV CMC 0,050 % 100 Hz to 2 kHz 20 mV to 50 mV CMC 0,045 % 2 kHz to 10 kHz 20 mV to 50 mV CMC 0,050 % 10 kHz to 30 kHz 20 mV to 50 mV CMC 0,090 % 30 kHz to 100 kHz 20 mV to 50 mV CMC 0,20 % 10 Hz to 100 Hz 50 mV to 100 mV CMC 0,035 % 100 Hz to 10 kHz 50 mV to 100 mV CMC 0,030 % 10k Hz to 30 kHz 50 mV to 100 mV CMC 0,060 % 30 kHz to 100 kHz 50 mV to 100 mV CMC 0,13 % 10 Hz to 100 Hz 100 mV to 190 mV CMC 0,030 % 100 Hz to 10 kHz 100 mV to 190 mV CMC 0,025 % 10 kHz to 30 kHz 100 mV to 190 mV CMC 0,050 % 30 kHz to 100 kHz 100 mV to 190 mV CMC 0,11 % 10 Hz to 40 Hz 190 mV to 500 mV CMC 0,026 % 40 Hz to 100 Hz 190 mV to 500 mV CMC 0,023 % 100 Hz to 2 kHz 190 mV to 500 mV CMC 0,020 % 2 kHz to 10 kHz 190 mV to 500 mV CMC 0,022 % 10 kHz to 30 kHz 190 mV to 500 mV CMC 0,047 % 30 kHz to 100 kHz 190 mV to 500 mV CMC 0,17 % 100 kHz to 300 kHz 190 mV to 500 mV CMC 1,4 % 10 Hz to 40 Hz 500 mV to 1 V CMC 0,019 % 40 Hz to 100 Hz 500 mV to 1 V CMC 0,015 % 100 Hz to 2 kHz 500 mV to 1 V CMC 0,013 % 2 kHz to 10 kHz 500 mV to 1 V CMC 0,014 % 10 kHz to 30 kHz 500 mV to 1 V CMC 0,030 % 30 kHz to 100 kHz 500 mV to 1 V CMC 0,10 % 100 kHz to 300 kHz 500 mV to 1 V CMC 0,75 % 10 Hz to 40 Hz 1 V to 1,9 V CMC 0,016 % 40 Hz to 100 Hz 1 V to 1,9 V CMC 0,013 % 100 Hz to 2 kHz 1 V to 1,9 V CMC 0,010 % 2 kHz to 10 kHz 1 V to 1,9 V CMC 0,012 % 10 kHz to 30 kHz 1 V to 1,9 V CMC 0,026 % 30 kHz to 100 kHz 1 V to 1,9 V CMC 0,082 % 100 kHz to 300 kHz 1 V to 1,9 V CMC 0,55 % 10 Hz to 40 Hz 1,9 V to 5 V CMC 0,026 % 40 Hz to 100 Hz 1,9 V to 5 V CMC 0,022 % 100 Hz to 2 kHz 1,9 V to 5 V CMC 0,019 % 2 kHz to 10 kHz 1,9 V to 5 V CMC 0,022 % 10 kHz to 30 kHz 1,9 V to 5 V CMC 0,045 % 30 kHz to 100 kHz 1,9 V to 5 V CMC 0,17 % 100 kHz to 300 kHz 1,9 V to 5 V CMC 1,4 % 10 Hz to 40 Hz 5 V to 10 V CMC 0,018 % 40 Hz to 100 Hz 5 V to 10 V CMC 0,015 % 100 Hz to 2 kHz 5 V to 10 V CMC 0,013 % 2 kHz to 10 kHz 5 V to 10 V CMC 0,017 % 10 kHz to 30 kHz 5 V to 10 V CMC 0,032 % 30 kHz to 100 kHz 5 V to 10 V CMC 0,11 % 100 kHz to 300 kHz 5 V to 10 V CMC 0,80 % 10 Hz to 40 Hz 10 V to 19 V CMC 0,016 % 40 Hz to 100 Hz 10 V to 19 V CMC 0,013 % 100 Hz to 2 kHz 10 V to 19 V CMC 0,010 % 2 kHz to 10 kHz 10 V to 19 V CMC 0,013 % 10 kHz to 30 kHz 10 V to 19 V CMC 0,027 % 30 kHz to 100 kHz 10 V to 19 V CMC 0,080 % 100 kHz to 300 kHz 10 V to 19 V CMC 0,55 % 10 Hz to 40 Hz 19 V to 50 V CMC 0,026 % 40 Hz to 100 Hz 19 V to 50 V CMC 0,022 % 100 Hz to 2 kHz 19 V to 50 V CMC 0,020 % 2 kHz to 10 kHz 19 V to 50 V CMC 0,021 % 10 kHz to 30 kHz 19 V to 50 V CMC 0,045 % 30 kHz to 100 kHz 19 V to 50 V CMC 0,16 % 10 Hz to 40 Hz 50 V to 100 V CMC 0,019 % 40 Hz to 100 Hz 50 V to 100 V CMC 0,015 % 100 Hz to 2 kHz 50 V to 100 V CMC 0,013 % 2 kHz to 10 kHz 50 V to 100 V CMC 0,015 % 10 kHz to 30 kHz 50 V to 100 V CMC 0,031 % 30 kHz to 100 kHz 50 V to 100 V CMC 0,11 % 10 Hz to 40 Hz 100 V to 190 V CMC 0,017 % 40 Hz to 100 Hz 100 V to 190 V CMC 0,013 % 100 Hz to 2 kHz 100 V to 190 V CMC 0,011 % 2 kHz to 10 kHz 100 V to 190 V CMC 0,012 % 10 kHz to 30 kHz 100 V to 190 V CMC 0,026 % 30 kHz to 100 kHz 100 V to 190 V CMC 0,078 % 40 Hz to 10 kHz 190 V to 500 V CMC 0,032 % 10 kHz to 30 kHz 190 V to 500 V CMC 0,070 % 40 Hz to 10 kHz 500 V CMC 0,023 % 10 kHz to 30 kHz 500 V CMC 0,055 % 40 Hz to 10 kHz 500 V to 1000 V CMC 0,040 % 10 kHz to 30 kHz 500 V to 1000 V CMC 0,16 % MKE-UST.1, MKE-SRP.1","search_zh":"交流电压 / 电源、校准器、电气安装检测仪 校准 – 电学量 用万用表直接测量 10 Hz 至 10 kHz 2 mV 至 10 mV CMC 0,40 % 10 kHz 至 30 kHz 2 mV 至 10 mV CMC 0,80 % 30 kHz 至 100 kHz 2 mV 至 10 mV CMC 1,7 % 10 Hz 至 100 Hz 10 mV 至 20 mV CMC 0,080 % 100 Hz 至 2 kHz 10 mV 至 20 mV CMC 0,065 % 2 kHz 至 10 kHz 10 mV 至 20 mV CMC 0,080 % 10 kHz 至 30 kHz 10 mV 至 20 mV CMC 0,14 % 30 kHz 至 100 kHz 10 mV 至 20 mV CMC 0,32 % 10 Hz 至 100 Hz 20 mV 至 50 mV CMC 0,050 % 100 Hz 至 2 kHz 20 mV 至 50 mV CMC 0,045 % 2 kHz 至 10 kHz 20 mV 至 50 mV CMC 0,050 % 10 kHz 至 30 kHz 20 mV 至 50 mV CMC 0,090 % 30 kHz 至 100 kHz 20 mV 至 50 mV CMC 0,20 % 10 Hz 至 100 Hz 50 mV 至 100 mV CMC 0,035 % 100 Hz 至 10 kHz 50 mV 至 100 mV CMC 0,030 % 10k Hz 至 30 kHz 50 mV 至 100 mV CMC 0,060 % 30 kHz 至 100 kHz 50 mV 至 100 mV CMC 0,13 % 10 Hz 至 100 Hz 100 mV 至 190 mV CMC 0,030 % 100 Hz 至 10 kHz 100 mV 至 190 mV CMC 0,025 % 10 kHz 至 30 kHz 100 mV 至 190 mV CMC 0,050 % 30 kHz 至 100 kHz 100 mV 至 190 mV CMC 0,11 % 10 Hz 至 40 Hz 190 mV 至 500 mV CMC 0,026 % 40 Hz 至 100 Hz 190 mV 至 500 mV CMC 0,023 % 100 Hz 至 2 kHz 190 mV 至 500 mV CMC 0,020 % 2 kHz 至 10 kHz 190 mV 至 500 mV CMC 0,022 % 10 kHz 至 30 kHz 190 mV 至 500 mV CMC 0,047 % 30 kHz 至 100 kHz 190 mV 至 500 mV CMC 0,17 % 100 kHz 至 300 kHz 190 mV 至 500 mV CMC 1,4 % 10 Hz 至 40 Hz 500 mV 至 1 V CMC 0,019 % 40 Hz 至 100 Hz 500 mV 至 1 V CMC 0,015 % 100 Hz 至 2 kHz 500 mV 至 1 V CMC 0,013 % 2 kHz 至 10 kHz 500 mV 至 1 V CMC 0,014 % 10 kHz 至 30 kHz 500 mV 至 1 V CMC 0,030 % 30 kHz 至 100 kHz 500 mV 至 1 V CMC 0,10 % 100 kHz 至 300 kHz 500 mV 至 1 V CMC 0,75 % 10 Hz 至 40 Hz 1 V 至 1,9 V CMC 0,016 % 40 Hz 至 100 Hz 1 V 至 1,9 V CMC 0,013 % 100 Hz 至 2 kHz 1 V 至 1,9 V CMC 0,010 % 2 kHz 至 10 kHz 1 V 至 1,9 V CMC 0,012 % 10 kHz 至 30 kHz 1 V 至 1,9 V CMC 0,026 % 30 kHz 至 100 kHz 1 V 至 1,9 V CMC 0,082 % 100 kHz 至 300 kHz 1 V 至 1,9 V CMC 0,55 % 10 Hz 至 40 Hz 1,9 V 至 5 V CMC 0,026 % 40 Hz 至 100 Hz 1,9 V 至 5 V CMC 0,022 % 100 Hz 至 2 kHz 1,9 V 至 5 V CMC 0,019 % 2 kHz 至 10 kHz 1,9 V 至 5 V CMC 0,022 % 10 kHz 至 30 kHz 1,9 V 至 5 V CMC 0,045 % 30 kHz 至 100 kHz 1,9 V 至 5 V CMC 0,17 % 100 kHz 至 300 kHz 1,9 V 至 5 V CMC 1,4 % 10 Hz 至 40 Hz 5 V 至 10 V CMC 0,018 % 40 Hz 至 100 Hz 5 V 至 10 V CMC 0,015 % 100 Hz 至 2 kHz 5 V 至 10 V CMC 0,013 % 2 kHz 至 10 kHz 5 V 至 10 V CMC 0,017 % 10 kHz 至 30 kHz 5 V 至 10 V CMC 0,032 % 30 kHz 至 100 kHz 5 V 至 10 V CMC 0,11 % 100 kHz 至 300 kHz 5 V 至 10 V CMC 0,80 % 10 Hz 至 40 Hz 10 V 至 19 V CMC 0,016 % 40 Hz 至 100 Hz 10 V 至 19 V CMC 0,013 % 100 Hz 至 2 kHz 10 V 至 19 V CMC 0,010 % 2 kHz 至 10 kHz 10 V 至 19 V CMC 0,013 % 10 kHz 至 30 kHz 10 V 至 19 V CMC 0,027 % 30 kHz 至 100 kHz 10 V 至 19 V CMC 0,080 % 100 kHz 至 300 kHz 10 V 至 19 V CMC 0,55 % 10 Hz 至 40 Hz 19 V 至 50 V CMC 0,026 % 40 Hz 至 100 Hz 19 V 至 50 V CMC 0,022 % 100 Hz 至 2 kHz 19 V 至 50 V CMC 0,020 % 2 kHz 至 10 kHz 19 V 至 50 V CMC 0,021 % 10 kHz 至 30 kHz 19 V 至 50 V CMC 0,045 % 30 kHz 至 100 kHz 19 V 至 50 V CMC 0,16 % 10 Hz 至 40 Hz 50 V 至 100 V CMC 0,019 % 40 Hz 至 100 Hz 50 V 至 100 V CMC 0,015 % 100 Hz 至 2 kHz 50 V 至 100 V CMC 0,013 % 2 kHz 至 10 kHz 50 V 至 100 V CMC 0,015 % 10 kHz 至 30 kHz 50 V 至 100 V CMC 0,031 % 30 kHz 至 100 kHz 50 V 至 100 V CMC 0,11 % 10 Hz 至 40 Hz 100 V 至 190 V CMC 0,017 % 40 Hz 至 100 Hz 100 V 至 190 V CMC 0,013 % 100 Hz 至 2 kHz 100 V 至 190 V CMC 0,011 % 2 kHz 至 10 kHz 100 V 至 190 V CMC 0,012 % 10 kHz 至 30 kHz 100 V 至 190 V CMC 0,026 % 30 kHz 至 100 kHz 100 V 至 190 V CMC 0,078 % 40 Hz 至 10 kHz 190 V 至 500 V CMC 0,032 % 10 kHz 至 30 kHz 190 V 至 500 V CMC 0,070 % 40 Hz 至 10 kHz 500 V CMC 0,023 % 10 kHz 至 30 kHz 500 V CMC 0,055 % 40 Hz 至 10 kHz 500 V 至 1000 V CMC 0,040 % 10 kHz 至 30 kHz 500 V 至 1000 V CMC 0,16 % MKE-UST.1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"885ad889a985986ba4690d01","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / woltomierze, multimetry, mierniki do badań instalacji elektrycznych","test_object_en":"AC voltage / Voltmeters, multimeters, inspection equipment","test_object_zh":"交流电压 / 电压表、万用表、电气安装检测仪","test_object_cs":"Střídavé napětí / Voltmetry, multimetry, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 50 kHz","range":"od 1 mV do 2,2 mV","cmc":"0,60 %"},{"name":"50 kHz do 100 kHz","range":"od 1 mV do 2,2 mV","cmc":"0,80 %"},{"name":"10 Hz do 100 kHz","range":"od 2,2 mV do 10 mV","cmc":"0,32 %"},{"name":"10 Hz do 40 Hz","range":"od 10 mV do 22 mV","cmc":"0,090 %"},{"name":"40 Hz do 20 kHz","range":"od 10 mV do 22 mV","cmc":"0,067 %"},{"name":"20 kHz do 50 kHz","range":"od 10 mV do 22 mV","cmc":"0,082 %"},{"name":"50 kHz do 100 kHz","range":"od 10 mV do 22 mV","cmc":"0,13 %"},{"name":"10 Hz do 40 Hz","range":"od 22 mV do 100 mV","cmc":"0,095 %"},{"name":"40 Hz do 20 kHz","range":"od 22 mV do 100 mV","cmc":"0,050 %"},{"name":"20 kHz do 50 kHz","range":"od 22 mV do 100 mV","cmc":"0,066 %"},{"name":"50 kHz do 100 kHz","range":"od 22 mV do 100 mV","cmc":"0,15 %"},{"name":"100 kHz do 300 kHz","range":"od 22 mV do 100 mV","cmc":"0,23 %"},{"name":"10 Hz do 40 Hz","range":"od 100 mV do 220 mV","cmc":"0,048 %"},{"name":"40 Hz do 20 kHz","range":"od 100 mV do 220 mV","cmc":"0,019 %"},{"name":"20 kHz do 50 kHz","range":"od 100 mV do 220 mV","cmc":"0,033 %"},{"name":"50 kHz do 100 kHz","range":"od 100 mV do 220 mV","cmc":"0,076 %"},{"name":"100 kHz do 300 kHz","range":"od 100 mV do 220 mV","cmc":"0,14 %"},{"name":"10 Hz do 40 Hz","range":"od 220 mV do 1 V","cmc":"0,053 %"},{"name":"40 Hz do 20 kHz","range":"od 220 mV do 1 V","cmc":"0,011 %"},{"name":"20 kHz do 50 kHz","range":"od 220 mV do 1 V","cmc":"0,016 %"},{"name":"50 kHz do 100 kHz","range":"od 220 mV do 1 V","cmc":"0,033 %"},{"name":"100 kHz do 300 kHz","range":"od 220 mV do 1 V","cmc":"0,093 %"},{"name":"10 Hz do 40 Hz","range":"od 1 V do 2,2 V","cmc":"0,039 %"},{"name":"40 Hz do 20 kHz","range":"od 1 V do 2,2 V","cmc":"0,008 %"},{"name":"20 kHz do 50 kHz","range":"od 1 V do 2,2 V","cmc":"0,012 %"},{"name":"50 kHz do 100 kHz","range":"od 1 V do 2,2 V","cmc":"0,019 %"},{"name":"100 kHz do 300 kHz","range":"od 1 V do 2,2 V","cmc":"0,070 %"},{"name":"10 Hz do 40 Hz","range":"od 2,2 V do 22 V","cmc":"0,060 %"},{"name":"40 Hz do 20 kHz","range":"od 2,2 V do 22 V","cmc":"0,008 %"},{"name":"20 kHz do 50 kHz","range":"od 2,2 V do 22 V","cmc":"0,015 %"},{"name":"50 kHz do 100 kHz","range":"od 2,2 V do 22 V","cmc":"0,023 %"},{"name":"100 kHz do 300 kHz","range":"od 2,2 V do 22 V","cmc":"0,065 %"},{"name":"10 Hz do 40 Hz","range":"od 22 V do 220 V","cmc":"0,055 %"},{"name":"40 Hz do 20 kHz","range":"od 22 V do 220 V","cmc":"0,010 %"},{"name":"20 kHz do 50 kHz","range":"od 22 V do 220 V","cmc":"0,015 %"},{"name":"50 kHz do 100 kHz","range":"od 22 V do 220 V","cmc":"0,031 %"},{"name":"50 Hz do 1 kHz","range":"od 220 V do 1000 V","cmc":"0,011 %"}],"parameters_en":[{"name":"10 Hz to 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,60 %"},{"name":"50 kHz to 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,80 %"},{"name":"10 Hz to 100 kHz","range":"2,2 mV to 10 mV","cmc":"0,32 %"},{"name":"10 Hz to 40 Hz","range":"10 mV to 22 mV","cmc":"0,090 %"},{"name":"40 Hz to 20 kHz","range":"10 mV to 22 mV","cmc":"0,067 %"},{"name":"20 kHz to 50 kHz","range":"10 mV to 22 mV","cmc":"0,082 %"},{"name":"50 kHz to 100 kHz","range":"10 mV to 22 mV","cmc":"0,13 %"},{"name":"10 Hz to 40 Hz","range":"22 mV to 100 mV","cmc":"0,095 %"},{"name":"40 Hz to 20 kHz","range":"22 mV to 100 mV","cmc":"0,050 %"},{"name":"20 kHz to 50 kHz","range":"22 mV to 100 mV","cmc":"0,066 %"},{"name":"50 kHz to 100 kHz","range":"22 mV to 100 mV","cmc":"0,15 %"},{"name":"100 kHz to 300 kHz","range":"22 mV to 100 mV","cmc":"0,23 %"},{"name":"10 Hz to 40 Hz","range":"100 mV to 220 mV","cmc":"0,048 %"},{"name":"40 Hz to 20 kHz","range":"100 mV to 220 mV","cmc":"0,019 %"},{"name":"20 kHz to 50 kHz","range":"100 mV to 220 mV","cmc":"0,033 %"},{"name":"50 kHz to 100 kHz","range":"100 mV to 220 mV","cmc":"0,076 %"},{"name":"100 kHz to 300 kHz","range":"100 mV to 220 mV","cmc":"0,14 %"},{"name":"10 Hz to 40 Hz","range":"220 mV to 1 V","cmc":"0,053 %"},{"name":"40 Hz to 20 kHz","range":"220 mV to 1 V","cmc":"0,011 %"},{"name":"20 kHz to 50 kHz","range":"220 mV to 1 V","cmc":"0,016 %"},{"name":"50 kHz to 100 kHz","range":"220 mV to 1 V","cmc":"0,033 %"},{"name":"100 kHz to 300 kHz","range":"220 mV to 1 V","cmc":"0,093 %"},{"name":"10 Hz to 40 Hz","range":"1 V to 2,2 V","cmc":"0,039 %"},{"name":"40 Hz to 20 kHz","range":"1 V to 2,2 V","cmc":"0,008 %"},{"name":"20 kHz to 50 kHz","range":"1 V to 2,2 V","cmc":"0,012 %"},{"name":"50 kHz to 100 kHz","range":"1 V to 2,2 V","cmc":"0,019 %"},{"name":"100 kHz to 300 kHz","range":"1 V to 2,2 V","cmc":"0,070 %"},{"name":"10 Hz to 40 Hz","range":"2,2 V to 22 V","cmc":"0,060 %"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 22 V","cmc":"0,008 %"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 22 V","cmc":"0,015 %"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 22 V","cmc":"0,023 %"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 22 V","cmc":"0,065 %"},{"name":"10 Hz to 40 Hz","range":"22 V to 220 V","cmc":"0,055 %"},{"name":"40 Hz to 20 kHz","range":"22 V to 220 V","cmc":"0,010 %"},{"name":"20 kHz to 50 kHz","range":"22 V to 220 V","cmc":"0,015 %"},{"name":"50 kHz to 100 kHz","range":"22 V to 220 V","cmc":"0,031 %"},{"name":"50 Hz to 1 kHz","range":"220 V to 1000 V","cmc":"0,011 %"}],"parameters_zh":[{"name":"10 Hz 至 50 kHz","range":"1 mV 至 2,2 mV","cmc":"0,60 %"},{"name":"50 kHz 至 100 kHz","range":"1 mV 至 2,2 mV","cmc":"0,80 %"},{"name":"10 Hz 至 100 kHz","range":"2,2 mV 至 10 mV","cmc":"0,32 %"},{"name":"10 Hz 至 40 Hz","range":"10 mV 至 22 mV","cmc":"0,090 %"},{"name":"40 Hz 至 20 kHz","range":"10 mV 至 22 mV","cmc":"0,067 %"},{"name":"20 kHz 至 50 kHz","range":"10 mV 至 22 mV","cmc":"0,082 %"},{"name":"50 kHz 至 100 kHz","range":"10 mV 至 22 mV","cmc":"0,13 %"},{"name":"10 Hz 至 40 Hz","range":"22 mV 至 100 mV","cmc":"0,095 %"},{"name":"40 Hz 至 20 kHz","range":"22 mV 至 100 mV","cmc":"0,050 %"},{"name":"20 kHz 至 50 kHz","range":"22 mV 至 100 mV","cmc":"0,066 %"},{"name":"50 kHz 至 100 kHz","range":"22 mV 至 100 mV","cmc":"0,15 %"},{"name":"100 kHz 至 300 kHz","range":"22 mV 至 100 mV","cmc":"0,23 %"},{"name":"10 Hz 至 40 Hz","range":"100 mV 至 220 mV","cmc":"0,048 %"},{"name":"40 Hz 至 20 kHz","range":"100 mV 至 220 mV","cmc":"0,019 %"},{"name":"20 kHz 至 50 kHz","range":"100 mV 至 220 mV","cmc":"0,033 %"},{"name":"50 kHz 至 100 kHz","range":"100 mV 至 220 mV","cmc":"0,076 %"},{"name":"100 kHz 至 300 kHz","range":"100 mV 至 220 mV","cmc":"0,14 %"},{"name":"10 Hz 至 40 Hz","range":"220 mV 至 1 V","cmc":"0,053 %"},{"name":"40 Hz 至 20 kHz","range":"220 mV 至 1 V","cmc":"0,011 %"},{"name":"20 kHz 至 50 kHz","range":"220 mV 至 1 V","cmc":"0,016 %"},{"name":"50 kHz 至 100 kHz","range":"220 mV 至 1 V","cmc":"0,033 %"},{"name":"100 kHz 至 300 kHz","range":"220 mV 至 1 V","cmc":"0,093 %"},{"name":"10 Hz 至 40 Hz","range":"1 V 至 2,2 V","cmc":"0,039 %"},{"name":"40 Hz 至 20 kHz","range":"1 V 至 2,2 V","cmc":"0,008 %"},{"name":"20 kHz 至 50 kHz","range":"1 V 至 2,2 V","cmc":"0,012 %"},{"name":"50 kHz 至 100 kHz","range":"1 V 至 2,2 V","cmc":"0,019 %"},{"name":"100 kHz 至 300 kHz","range":"1 V 至 2,2 V","cmc":"0,070 %"},{"name":"10 Hz 至 40 Hz","range":"2,2 V 至 22 V","cmc":"0,060 %"},{"name":"40 Hz 至 20 kHz","range":"2,2 V 至 22 V","cmc":"0,008 %"},{"name":"20 kHz 至 50 kHz","range":"2,2 V 至 22 V","cmc":"0,015 %"},{"name":"50 kHz 至 100 kHz","range":"2,2 V 至 22 V","cmc":"0,023 %"},{"name":"100 kHz 至 300 kHz","range":"2,2 V 至 22 V","cmc":"0,065 %"},{"name":"10 Hz 至 40 Hz","range":"22 V 至 220 V","cmc":"0,055 %"},{"name":"40 Hz 至 20 kHz","range":"22 V 至 220 V","cmc":"0,010 %"},{"name":"20 kHz 至 50 kHz","range":"22 V 至 220 V","cmc":"0,015 %"},{"name":"50 kHz 至 100 kHz","range":"22 V 至 220 V","cmc":"0,031 %"},{"name":"50 Hz 至 1 kHz","range":"220 V 至 1000 V","cmc":"0,011 %"}],"parameters_cs":[{"name":"10 Hz až 50 kHz","range":"1 mV až 2,2 mV","cmc":"0,60 %"},{"name":"50 kHz až 100 kHz","range":"1 mV až 2,2 mV","cmc":"0,80 %"},{"name":"10 Hz až 100 kHz","range":"2,2 mV až 10 mV","cmc":"0,32 %"},{"name":"10 Hz až 40 Hz","range":"10 mV až 22 mV","cmc":"0,090 %"},{"name":"40 Hz až 20 kHz","range":"10 mV až 22 mV","cmc":"0,067 %"},{"name":"20 kHz až 50 kHz","range":"10 mV až 22 mV","cmc":"0,082 %"},{"name":"50 kHz až 100 kHz","range":"10 mV až 22 mV","cmc":"0,13 %"},{"name":"10 Hz až 40 Hz","range":"22 mV až 100 mV","cmc":"0,095 %"},{"name":"40 Hz až 20 kHz","range":"22 mV až 100 mV","cmc":"0,050 %"},{"name":"20 kHz až 50 kHz","range":"22 mV až 100 mV","cmc":"0,066 %"},{"name":"50 kHz až 100 kHz","range":"22 mV až 100 mV","cmc":"0,15 %"},{"name":"100 kHz až 300 kHz","range":"22 mV až 100 mV","cmc":"0,23 %"},{"name":"10 Hz až 40 Hz","range":"100 mV až 220 mV","cmc":"0,048 %"},{"name":"40 Hz až 20 kHz","range":"100 mV až 220 mV","cmc":"0,019 %"},{"name":"20 kHz až 50 kHz","range":"100 mV až 220 mV","cmc":"0,033 %"},{"name":"50 kHz až 100 kHz","range":"100 mV až 220 mV","cmc":"0,076 %"},{"name":"100 kHz až 300 kHz","range":"100 mV až 220 mV","cmc":"0,14 %"},{"name":"10 Hz až 40 Hz","range":"220 mV až 1 V","cmc":"0,053 %"},{"name":"40 Hz až 20 kHz","range":"220 mV až 1 V","cmc":"0,011 %"},{"name":"20 kHz až 50 kHz","range":"220 mV až 1 V","cmc":"0,016 %"},{"name":"50 kHz až 100 kHz","range":"220 mV až 1 V","cmc":"0,033 %"},{"name":"100 kHz až 300 kHz","range":"220 mV až 1 V","cmc":"0,093 %"},{"name":"10 Hz až 40 Hz","range":"1 V až 2,2 V","cmc":"0,039 %"},{"name":"40 Hz až 20 kHz","range":"1 V až 2,2 V","cmc":"0,008 %"},{"name":"20 kHz až 50 kHz","range":"1 V až 2,2 V","cmc":"0,012 %"},{"name":"50 kHz až 100 kHz","range":"1 V až 2,2 V","cmc":"0,019 %"},{"name":"100 kHz až 300 kHz","range":"1 V až 2,2 V","cmc":"0,070 %"},{"name":"10 Hz až 40 Hz","range":"2,2 V až 22 V","cmc":"0,060 %"},{"name":"40 Hz až 20 kHz","range":"2,2 V až 22 V","cmc":"0,008 %"},{"name":"20 kHz až 50 kHz","range":"2,2 V až 22 V","cmc":"0,015 %"},{"name":"50 kHz až 100 kHz","range":"2,2 V až 22 V","cmc":"0,023 %"},{"name":"100 kHz až 300 kHz","range":"2,2 V až 22 V","cmc":"0,065 %"},{"name":"10 Hz až 40 Hz","range":"22 V až 220 V","cmc":"0,055 %"},{"name":"40 Hz až 20 kHz","range":"22 V až 220 V","cmc":"0,010 %"},{"name":"20 kHz až 50 kHz","range":"22 V až 220 V","cmc":"0,015 %"},{"name":"50 kHz až 100 kHz","range":"22 V až 220 V","cmc":"0,031 %"},{"name":"50 Hz až 1 kHz","range":"220 V až 1000 V","cmc":"0,011 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 50 kHz od 1 mV do 2,2 mV CMC 0,60 %\n50 kHz do 100 kHz od 1 mV do 2,2 mV CMC 0,80 %\n10 Hz do 100 kHz od 2,2 mV do 10 mV CMC 0,32 %\n10 Hz do 40 Hz od 10 mV do 22 mV CMC 0,090 %\n40 Hz do 20 kHz od 10 mV do 22 mV CMC 0,067 %\n20 kHz do 50 kHz od 10 mV do 22 mV CMC 0,082 %\n50 kHz do 100 kHz od 10 mV do 22 mV CMC 0,13 %\n10 Hz do 40 Hz od 22 mV do 100 mV CMC 0,095 %\n40 Hz do 20 kHz od 22 mV do 100 mV CMC 0,050 %\n20 kHz do 50 kHz od 22 mV do 100 mV CMC 0,066 %\n50 kHz do 100 kHz od 22 mV do 100 mV CMC 0,15 %\n100 kHz do 300 kHz od 22 mV do 100 mV CMC 0,23 %\n10 Hz do 40 Hz od 100 mV do 220 mV CMC 0,048 %\n40 Hz do 20 kHz od 100 mV do 220 mV CMC 0,019 %\n20 kHz do 50 kHz od 100 mV do 220 mV CMC 0,033 %\n50 kHz do 100 kHz od 100 mV do 220 mV CMC 0,076 %\n100 kHz do 300 kHz od 100 mV do 220 mV CMC 0,14 %\n10 Hz do 40 Hz od 220 mV do 1 V CMC 0,053 %\n40 Hz do 20 kHz od 220 mV do 1 V CMC 0,011 %\n20 kHz do 50 kHz od 220 mV do 1 V CMC 0,016 %\n50 kHz do 100 kHz od 220 mV do 1 V CMC 0,033 %\n100 kHz do 300 kHz od 220 mV do 1 V CMC 0,093 %\n10 Hz do 40 Hz od 1 V do 2,2 V CMC 0,039 %\n40 Hz do 20 kHz od 1 V do 2,2 V CMC 0,008 %\n20 kHz do 50 kHz od 1 V do 2,2 V CMC 0,012 %\n50 kHz do 100 kHz od 1 V do 2,2 V CMC 0,019 %\n100 kHz do 300 kHz od 1 V do 2,2 V CMC 0,070 %\n10 Hz do 40 Hz od 2,2 V do 22 V CMC 0,060 %\n40 Hz do 20 kHz od 2,2 V do 22 V CMC 0,008 %\n20 kHz do 50 kHz od 2,2 V do 22 V CMC 0,015 %\n50 kHz do 100 kHz od 2,2 V do 22 V CMC 0,023 %\n100 kHz do 300 kHz od 2,2 V do 22 V CMC 0,065 %\n10 Hz do 40 Hz od 22 V do 220 V CMC 0,055 %\n40 Hz do 20 kHz od 22 V do 220 V CMC 0,010 %\n20 kHz do 50 kHz od 22 V do 220 V CMC 0,015 %\n50 kHz do 100 kHz od 22 V do 220 V CMC 0,031 %\n50 Hz do 1 kHz od 220 V do 1000 V CMC 0,011 %\nBezpośrednie generowanie kalibratorem","reference":"MKE-UST1, MKE-SRP.1","norm_bases":["MKE-UST1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / woltomierze, multimetry, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 10 Hz do 50 kHz od 1 mV do 2,2 mV CMC 0,60 % 50 kHz do 100 kHz od 1 mV do 2,2 mV CMC 0,80 % 10 Hz do 100 kHz od 2,2 mV do 10 mV CMC 0,32 % 10 Hz do 40 Hz od 10 mV do 22 mV CMC 0,090 % 40 Hz do 20 kHz od 10 mV do 22 mV CMC 0,067 % 20 kHz do 50 kHz od 10 mV do 22 mV CMC 0,082 % 50 kHz do 100 kHz od 10 mV do 22 mV CMC 0,13 % 10 Hz do 40 Hz od 22 mV do 100 mV CMC 0,095 % 40 Hz do 20 kHz od 22 mV do 100 mV CMC 0,050 % 20 kHz do 50 kHz od 22 mV do 100 mV CMC 0,066 % 50 kHz do 100 kHz od 22 mV do 100 mV CMC 0,15 % 100 kHz do 300 kHz od 22 mV do 100 mV CMC 0,23 % 10 Hz do 40 Hz od 100 mV do 220 mV CMC 0,048 % 40 Hz do 20 kHz od 100 mV do 220 mV CMC 0,019 % 20 kHz do 50 kHz od 100 mV do 220 mV CMC 0,033 % 50 kHz do 100 kHz od 100 mV do 220 mV CMC 0,076 % 100 kHz do 300 kHz od 100 mV do 220 mV CMC 0,14 % 10 Hz do 40 Hz od 220 mV do 1 V CMC 0,053 % 40 Hz do 20 kHz od 220 mV do 1 V CMC 0,011 % 20 kHz do 50 kHz od 220 mV do 1 V CMC 0,016 % 50 kHz do 100 kHz od 220 mV do 1 V CMC 0,033 % 100 kHz do 300 kHz od 220 mV do 1 V CMC 0,093 % 10 Hz do 40 Hz od 1 V do 2,2 V CMC 0,039 % 40 Hz do 20 kHz od 1 V do 2,2 V CMC 0,008 % 20 kHz do 50 kHz od 1 V do 2,2 V CMC 0,012 % 50 kHz do 100 kHz od 1 V do 2,2 V CMC 0,019 % 100 kHz do 300 kHz od 1 V do 2,2 V CMC 0,070 % 10 Hz do 40 Hz od 2,2 V do 22 V CMC 0,060 % 40 Hz do 20 kHz od 2,2 V do 22 V CMC 0,008 % 20 kHz do 50 kHz od 2,2 V do 22 V CMC 0,015 % 50 kHz do 100 kHz od 2,2 V do 22 V CMC 0,023 % 100 kHz do 300 kHz od 2,2 V do 22 V CMC 0,065 % 10 Hz do 40 Hz od 22 V do 220 V CMC 0,055 % 40 Hz do 20 kHz od 22 V do 220 V CMC 0,010 % 20 kHz do 50 kHz od 22 V do 220 V CMC 0,015 % 50 kHz do 100 kHz od 22 V do 220 V CMC 0,031 % 50 Hz do 1 kHz od 220 V do 1000 V CMC 0,011 % Střídavé napětí / Voltmetry, multimetry, revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 10 Hz až 50 kHz 1 mV až 2,2 mV CMC 0,60 % 50 kHz až 100 kHz 1 mV až 2,2 mV CMC 0,80 % 10 Hz až 100 kHz 2,2 mV až 10 mV CMC 0,32 % 10 Hz až 40 Hz 10 mV až 22 mV CMC 0,090 % 40 Hz až 20 kHz 10 mV až 22 mV CMC 0,067 % 20 kHz až 50 kHz 10 mV až 22 mV CMC 0,082 % 50 kHz až 100 kHz 10 mV až 22 mV CMC 0,13 % 10 Hz až 40 Hz 22 mV až 100 mV CMC 0,095 % 40 Hz až 20 kHz 22 mV až 100 mV CMC 0,050 % 20 kHz až 50 kHz 22 mV až 100 mV CMC 0,066 % 50 kHz až 100 kHz 22 mV až 100 mV CMC 0,15 % 100 kHz až 300 kHz 22 mV až 100 mV CMC 0,23 % 10 Hz až 40 Hz 100 mV až 220 mV CMC 0,048 % 40 Hz až 20 kHz 100 mV až 220 mV CMC 0,019 % 20 kHz až 50 kHz 100 mV až 220 mV CMC 0,033 % 50 kHz až 100 kHz 100 mV až 220 mV CMC 0,076 % 100 kHz až 300 kHz 100 mV až 220 mV CMC 0,14 % 10 Hz až 40 Hz 220 mV až 1 V CMC 0,053 % 40 Hz až 20 kHz 220 mV až 1 V CMC 0,011 % 20 kHz až 50 kHz 220 mV až 1 V CMC 0,016 % 50 kHz až 100 kHz 220 mV až 1 V CMC 0,033 % 100 kHz až 300 kHz 220 mV až 1 V CMC 0,093 % 10 Hz až 40 Hz 1 V až 2,2 V CMC 0,039 % 40 Hz až 20 kHz 1 V až 2,2 V CMC 0,008 % 20 kHz až 50 kHz 1 V až 2,2 V CMC 0,012 % 50 kHz až 100 kHz 1 V až 2,2 V CMC 0,019 % 100 kHz až 300 kHz 1 V až 2,2 V CMC 0,070 % 10 Hz až 40 Hz 2,2 V až 22 V CMC 0,060 % 40 Hz až 20 kHz 2,2 V až 22 V CMC 0,008 % 20 kHz až 50 kHz 2,2 V až 22 V CMC 0,015 % 50 kHz až 100 kHz 2,2 V až 22 V CMC 0,023 % 100 kHz až 300 kHz 2,2 V až 22 V CMC 0,065 % 10 Hz až 40 Hz 22 V až 220 V CMC 0,055 % 40 Hz až 20 kHz 22 V až 220 V CMC 0,010 % 20 kHz až 50 kHz 22 V až 220 V CMC 0,015 % 50 kHz až 100 kHz 22 V až 220 V CMC 0,031 % 50 Hz až 1 kHz 220 V až 1000 V CMC 0,011 % MKE-UST1, MKE-SRP.1 Napiecie przemienne / woltomierze, multimetry, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 10 Hz do 50 kHz od 1 mV do 2,2 mV CMC 0,60 % 50 kHz do 100 kHz od 1 mV do 2,2 mV CMC 0,80 % 10 Hz do 100 kHz od 2,2 mV do 10 mV CMC 0,32 % 10 Hz do 40 Hz od 10 mV do 22 mV CMC 0,090 % 40 Hz do 20 kHz od 10 mV do 22 mV CMC 0,067 % 20 kHz do 50 kHz od 10 mV do 22 mV CMC 0,082 % 50 kHz do 100 kHz od 10 mV do 22 mV CMC 0,13 % 10 Hz do 40 Hz od 22 mV do 100 mV CMC 0,095 % 40 Hz do 20 kHz od 22 mV do 100 mV CMC 0,050 % 20 kHz do 50 kHz od 22 mV do 100 mV CMC 0,066 % 50 kHz do 100 kHz od 22 mV do 100 mV CMC 0,15 % 100 kHz do 300 kHz od 22 mV do 100 mV CMC 0,23 % 10 Hz do 40 Hz od 100 mV do 220 mV CMC 0,048 % 40 Hz do 20 kHz od 100 mV do 220 mV CMC 0,019 % 20 kHz do 50 kHz od 100 mV do 220 mV CMC 0,033 % 50 kHz do 100 kHz od 100 mV do 220 mV CMC 0,076 % 100 kHz do 300 kHz od 100 mV do 220 mV CMC 0,14 % 10 Hz do 40 Hz od 220 mV do 1 V CMC 0,053 % 40 Hz do 20 kHz od 220 mV do 1 V CMC 0,011 % 20 kHz do 50 kHz od 220 mV do 1 V CMC 0,016 % 50 kHz do 100 kHz od 220 mV do 1 V CMC 0,033 % 100 kHz do 300 kHz od 220 mV do 1 V CMC 0,093 % 10 Hz do 40 Hz od 1 V do 2,2 V CMC 0,039 % 40 Hz do 20 kHz od 1 V do 2,2 V CMC 0,008 % 20 kHz do 50 kHz od 1 V do 2,2 V CMC 0,012 % 50 kHz do 100 kHz od 1 V do 2,2 V CMC 0,019 % 100 kHz do 300 kHz od 1 V do 2,2 V CMC 0,070 % 10 Hz do 40 Hz od 2,2 V do 22 V CMC 0,060 % 40 Hz do 20 kHz od 2,2 V do 22 V CMC 0,008 % 20 kHz do 50 kHz od 2,2 V do 22 V CMC 0,015 % 50 kHz do 100 kHz od 2,2 V do 22 V CMC 0,023 % 100 kHz do 300 kHz od 2,2 V do 22 V CMC 0,065 % 10 Hz do 40 Hz od 22 V do 220 V CMC 0,055 % 40 Hz do 20 kHz od 22 V do 220 V CMC 0,010 % 20 kHz do 50 kHz od 22 V do 220 V CMC 0,015 % 50 kHz do 100 kHz od 22 V do 220 V CMC 0,031 % 50 Hz do 1 kHz od 220 V do 1000 V CMC 0,011 % Stridave napeti / Voltmetry, multimetry, revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 10 Hz az 50 kHz 1 mV az 2,2 mV CMC 0,60 % 50 kHz az 100 kHz 1 mV az 2,2 mV CMC 0,80 % 10 Hz az 100 kHz 2,2 mV az 10 mV CMC 0,32 % 10 Hz az 40 Hz 10 mV az 22 mV CMC 0,090 % 40 Hz az 20 kHz 10 mV az 22 mV CMC 0,067 % 20 kHz az 50 kHz 10 mV az 22 mV CMC 0,082 % 50 kHz az 100 kHz 10 mV az 22 mV CMC 0,13 % 10 Hz az 40 Hz 22 mV az 100 mV CMC 0,095 % 40 Hz az 20 kHz 22 mV az 100 mV CMC 0,050 % 20 kHz az 50 kHz 22 mV az 100 mV CMC 0,066 % 50 kHz az 100 kHz 22 mV az 100 mV CMC 0,15 % 100 kHz az 300 kHz 22 mV az 100 mV CMC 0,23 % 10 Hz az 40 Hz 100 mV az 220 mV CMC 0,048 % 40 Hz az 20 kHz 100 mV az 220 mV CMC 0,019 % 20 kHz az 50 kHz 100 mV az 220 mV CMC 0,033 % 50 kHz az 100 kHz 100 mV az 220 mV CMC 0,076 % 100 kHz az 300 kHz 100 mV az 220 mV CMC 0,14 % 10 Hz az 40 Hz 220 mV az 1 V CMC 0,053 % 40 Hz az 20 kHz 220 mV az 1 V CMC 0,011 % 20 kHz az 50 kHz 220 mV az 1 V CMC 0,016 % 50 kHz az 100 kHz 220 mV az 1 V CMC 0,033 % 100 kHz az 300 kHz 220 mV az 1 V CMC 0,093 % 10 Hz az 40 Hz 1 V az 2,2 V CMC 0,039 % 40 Hz az 20 kHz 1 V az 2,2 V CMC 0,008 % 20 kHz az 50 kHz 1 V az 2,2 V CMC 0,012 % 50 kHz az 100 kHz 1 V az 2,2 V CMC 0,019 % 100 kHz az 300 kHz 1 V az 2,2 V CMC 0,070 % 10 Hz az 40 Hz 2,2 V az 22 V CMC 0,060 % 40 Hz az 20 kHz 2,2 V az 22 V CMC 0,008 % 20 kHz az 50 kHz 2,2 V az 22 V CMC 0,015 % 50 kHz az 100 kHz 2,2 V az 22 V CMC 0,023 % 100 kHz az 300 kHz 2,2 V az 22 V CMC 0,065 % 10 Hz az 40 Hz 22 V az 220 V CMC 0,055 % 40 Hz az 20 kHz 22 V az 220 V CMC 0,010 % 20 kHz az 50 kHz 22 V az 220 V CMC 0,015 % 50 kHz az 100 kHz 22 V az 220 V CMC 0,031 % 50 Hz az 1 kHz 220 V az 1000 V CMC 0,011 % MKE-UST1, MKE-SRP.1","search_en":"AC voltage / Voltmeters, multimeters, inspection equipment Calibration – electrical quantities Direct generation with a calibrator 10 Hz to 50 kHz 1 mV to 2,2 mV CMC 0,60 % 50 kHz to 100 kHz 1 mV to 2,2 mV CMC 0,80 % 10 Hz to 100 kHz 2,2 mV to 10 mV CMC 0,32 % 10 Hz to 40 Hz 10 mV to 22 mV CMC 0,090 % 40 Hz to 20 kHz 10 mV to 22 mV CMC 0,067 % 20 kHz to 50 kHz 10 mV to 22 mV CMC 0,082 % 50 kHz to 100 kHz 10 mV to 22 mV CMC 0,13 % 10 Hz to 40 Hz 22 mV to 100 mV CMC 0,095 % 40 Hz to 20 kHz 22 mV to 100 mV CMC 0,050 % 20 kHz to 50 kHz 22 mV to 100 mV CMC 0,066 % 50 kHz to 100 kHz 22 mV to 100 mV CMC 0,15 % 100 kHz to 300 kHz 22 mV to 100 mV CMC 0,23 % 10 Hz to 40 Hz 100 mV to 220 mV CMC 0,048 % 40 Hz to 20 kHz 100 mV to 220 mV CMC 0,019 % 20 kHz to 50 kHz 100 mV to 220 mV CMC 0,033 % 50 kHz to 100 kHz 100 mV to 220 mV CMC 0,076 % 100 kHz to 300 kHz 100 mV to 220 mV CMC 0,14 % 10 Hz to 40 Hz 220 mV to 1 V CMC 0,053 % 40 Hz to 20 kHz 220 mV to 1 V CMC 0,011 % 20 kHz to 50 kHz 220 mV to 1 V CMC 0,016 % 50 kHz to 100 kHz 220 mV to 1 V CMC 0,033 % 100 kHz to 300 kHz 220 mV to 1 V CMC 0,093 % 10 Hz to 40 Hz 1 V to 2,2 V CMC 0,039 % 40 Hz to 20 kHz 1 V to 2,2 V CMC 0,008 % 20 kHz to 50 kHz 1 V to 2,2 V CMC 0,012 % 50 kHz to 100 kHz 1 V to 2,2 V CMC 0,019 % 100 kHz to 300 kHz 1 V to 2,2 V CMC 0,070 % 10 Hz to 40 Hz 2,2 V to 22 V CMC 0,060 % 40 Hz to 20 kHz 2,2 V to 22 V CMC 0,008 % 20 kHz to 50 kHz 2,2 V to 22 V CMC 0,015 % 50 kHz to 100 kHz 2,2 V to 22 V CMC 0,023 % 100 kHz to 300 kHz 2,2 V to 22 V CMC 0,065 % 10 Hz to 40 Hz 22 V to 220 V CMC 0,055 % 40 Hz to 20 kHz 22 V to 220 V CMC 0,010 % 20 kHz to 50 kHz 22 V to 220 V CMC 0,015 % 50 kHz to 100 kHz 22 V to 220 V CMC 0,031 % 50 Hz to 1 kHz 220 V to 1000 V CMC 0,011 % MKE-UST1, MKE-SRP.1","search_zh":"交流电压 / 电压表、万用表、电气安装检测仪 校准 – 电学量 用校准器直接产生 10 Hz 至 50 kHz 1 mV 至 2,2 mV CMC 0,60 % 50 kHz 至 100 kHz 1 mV 至 2,2 mV CMC 0,80 % 10 Hz 至 100 kHz 2,2 mV 至 10 mV CMC 0,32 % 10 Hz 至 40 Hz 10 mV 至 22 mV CMC 0,090 % 40 Hz 至 20 kHz 10 mV 至 22 mV CMC 0,067 % 20 kHz 至 50 kHz 10 mV 至 22 mV CMC 0,082 % 50 kHz 至 100 kHz 10 mV 至 22 mV CMC 0,13 % 10 Hz 至 40 Hz 22 mV 至 100 mV CMC 0,095 % 40 Hz 至 20 kHz 22 mV 至 100 mV CMC 0,050 % 20 kHz 至 50 kHz 22 mV 至 100 mV CMC 0,066 % 50 kHz 至 100 kHz 22 mV 至 100 mV CMC 0,15 % 100 kHz 至 300 kHz 22 mV 至 100 mV CMC 0,23 % 10 Hz 至 40 Hz 100 mV 至 220 mV CMC 0,048 % 40 Hz 至 20 kHz 100 mV 至 220 mV CMC 0,019 % 20 kHz 至 50 kHz 100 mV 至 220 mV CMC 0,033 % 50 kHz 至 100 kHz 100 mV 至 220 mV CMC 0,076 % 100 kHz 至 300 kHz 100 mV 至 220 mV CMC 0,14 % 10 Hz 至 40 Hz 220 mV 至 1 V CMC 0,053 % 40 Hz 至 20 kHz 220 mV 至 1 V CMC 0,011 % 20 kHz 至 50 kHz 220 mV 至 1 V CMC 0,016 % 50 kHz 至 100 kHz 220 mV 至 1 V CMC 0,033 % 100 kHz 至 300 kHz 220 mV 至 1 V CMC 0,093 % 10 Hz 至 40 Hz 1 V 至 2,2 V CMC 0,039 % 40 Hz 至 20 kHz 1 V 至 2,2 V CMC 0,008 % 20 kHz 至 50 kHz 1 V 至 2,2 V CMC 0,012 % 50 kHz 至 100 kHz 1 V 至 2,2 V CMC 0,019 % 100 kHz 至 300 kHz 1 V 至 2,2 V CMC 0,070 % 10 Hz 至 40 Hz 2,2 V 至 22 V CMC 0,060 % 40 Hz 至 20 kHz 2,2 V 至 22 V CMC 0,008 % 20 kHz 至 50 kHz 2,2 V 至 22 V CMC 0,015 % 50 kHz 至 100 kHz 2,2 V 至 22 V CMC 0,023 % 100 kHz 至 300 kHz 2,2 V 至 22 V CMC 0,065 % 10 Hz 至 40 Hz 22 V 至 220 V CMC 0,055 % 40 Hz 至 20 kHz 22 V 至 220 V CMC 0,010 % 20 kHz 至 50 kHz 22 V 至 220 V CMC 0,015 % 50 kHz 至 100 kHz 22 V 至 220 V CMC 0,031 % 50 Hz 至 1 kHz 220 V 至 1000 V CMC 0,011 % MKE-UST1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3961560c1f223576cc65a7fc","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"5","test_object":"Wartość międzyszczytowa prostokątnego napięcia przemiennego / oscyloskopy","test_object_en":"Peak-to-peak value of square wave AC voltage / Oscilloscopes","test_object_zh":"方波交流电压峰峰值 / 示波器","test_object_cs":"Mezivrcholová hodnota obdélníkového střídavého napětí / Osciloskopy","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 Hz do 100 kHz","range":"od 1 mV do 2 mV","cmc":"0,30 % + 10 µV"},{"name":"10 Hz do 100 kHz","range":"od 2 mV do 100 mV","cmc":"0,20 % + 10 µV"},{"name":"10 Hz do 100 kHz","range":"od 100 mV do 220 V","cmc":"0,15 %"}],"parameters_en":[{"name":"10 Hz to 100 kHz","range":"1 mV to 2 mV","cmc":"0,30 % + 10 µV"},{"name":"10 Hz to 100 kHz","range":"2 mV to 100 mV","cmc":"0,20 % + 10 µV"},{"name":"10 Hz to 100 kHz","range":"100 mV to 220 V","cmc":"0,15 %"}],"parameters_zh":[{"name":"10 Hz 至 100 kHz","range":"1 mV 至 2 mV","cmc":"0,30 % + 10 µV"},{"name":"10 Hz 至 100 kHz","range":"2 mV 至 100 mV","cmc":"0,20 % + 10 µV"},{"name":"10 Hz 至 100 kHz","range":"100 mV 至 220 V","cmc":"0,15 %"}],"parameters_cs":[{"name":"10 Hz až 100 kHz","range":"1 mV až 2 mV","cmc":"0,30 % + 10 µV"},{"name":"10 Hz až 100 kHz","range":"2 mV až 100 mV","cmc":"0,20 % + 10 µV"},{"name":"10 Hz až 100 kHz","range":"100 mV až 220 V","cmc":"0,15 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 Hz do 100 kHz od 1 mV do 2 mV CMC 0,30 % + 10 µV\n10 Hz do 100 kHz od 2 mV do 100 mV CMC 0,20 % + 10 µV\n10 Hz do 100 kHz od 100 mV do 220 V CMC 0,15 %\nBezpośrednie generowanie kalibratorem","reference":"MKE-UST1","norm_bases":["MKE-UST1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wartość międzyszczytowa prostokątnego napięcia przemiennego / oscyloskopy Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 10 Hz do 100 kHz od 1 mV do 2 mV CMC 0,30 % + 10 µV 10 Hz do 100 kHz od 2 mV do 100 mV CMC 0,20 % + 10 µV 10 Hz do 100 kHz od 100 mV do 220 V CMC 0,15 % Mezivrcholová hodnota obdélníkového střídavého napětí / Osciloskopy Kalibrace – elektrické veličiny Přímé generování kalibrátorem 10 Hz až 100 kHz 1 mV až 2 mV CMC 0,30 % + 10 µV 10 Hz až 100 kHz 2 mV až 100 mV CMC 0,20 % + 10 µV 10 Hz až 100 kHz 100 mV až 220 V CMC 0,15 % MKE-UST1 Wartosc miedzyszczytowa prostokatnego napiecia przemiennego / oscyloskopy Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 10 Hz do 100 kHz od 1 mV do 2 mV CMC 0,30 % + 10 µV 10 Hz do 100 kHz od 2 mV do 100 mV CMC 0,20 % + 10 µV 10 Hz do 100 kHz od 100 mV do 220 V CMC 0,15 % Mezivrcholova hodnota obdelnikoveho stridaveho napeti / Osciloskopy Kalibrace – elektricke veliciny Prime generovani kalibratorem 10 Hz az 100 kHz 1 mV az 2 mV CMC 0,30 % + 10 µV 10 Hz az 100 kHz 2 mV az 100 mV CMC 0,20 % + 10 µV 10 Hz az 100 kHz 100 mV az 220 V CMC 0,15 % MKE-UST1","search_en":"Peak-to-peak value of square wave AC voltage / Oscilloscopes Calibration – electrical quantities Direct generation with a calibrator 10 Hz to 100 kHz 1 mV to 2 mV CMC 0,30 % + 10 µV 10 Hz to 100 kHz 2 mV to 100 mV CMC 0,20 % + 10 µV 10 Hz to 100 kHz 100 mV to 220 V CMC 0,15 % MKE-UST1","search_zh":"方波交流电压峰峰值 / 示波器 校准 – 电学量 用校准器直接产生 10 Hz 至 100 kHz 1 mV 至 2 mV CMC 0,30 % + 10 µV 10 Hz 至 100 kHz 2 mV 至 100 mV CMC 0,20 % + 10 µV 10 Hz 至 100 kHz 100 mV 至 220 V CMC 0,15 % MKE-UST1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0467c0f1dda1db1dd20ecf9d","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"DC current / Power supplies, calibrators, inspection instruments","test_object_zh":"直流电流 / 电源、校准器、电气安装检测仪","test_object_cs":"Stejnosměrný proud / Zdroje, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 nA do 2 nA","cmc":"0,40 %"},{"name":"","range":"od 2 nA do 50 nA","cmc":"0,30 %"},{"name":"","range":"od 50 nA do 200 nA","cmc":"0,20 %"},{"name":"","range":"od 200 nA do 1 µA","cmc":"0,25 %"}],"parameters_en":[{"name":"","range":"1 nA to 2 nA","cmc":"0,40 %"},{"name":"","range":"2 nA to 50 nA","cmc":"0,30 %"},{"name":"","range":"50 nA to 200 nA","cmc":"0,20 %"},{"name":"","range":"200 nA to 1 µA","cmc":"0,25 %"}],"parameters_zh":[{"name":"","range":"1 nA 至 2 nA","cmc":"0,40 %"},{"name":"","range":"2 nA 至 50 nA","cmc":"0,30 %"},{"name":"","range":"50 nA 至 200 nA","cmc":"0,20 %"},{"name":"","range":"200 nA 至 1 µA","cmc":"0,25 %"}],"parameters_cs":[{"name":"","range":"1 nA až 2 nA","cmc":"0,40 %"},{"name":"","range":"2 nA až 50 nA","cmc":"0,30 %"},{"name":"","range":"50 nA až 200 nA","cmc":"0,20 %"},{"name":"","range":"200 nA až 1 µA","cmc":"0,25 %"}],"technique":"Pomiar bezpośredni pikoamperomierzem","technique_en":"Direct measurement with a picoammeter","technique_zh":"用皮安表直接测量","technique_cs":"Přímé měření pikoampérmetrem","techniques":["Pomiar bezpośredni pikoamperomierzem"],"techniques_en":["Direct measurement with a picoammeter"],"techniques_zh":["用皮安表直接测量"],"techniques_cs":["Přímé měření pikoampérmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 nA do 2 nA CMC 0,40 %\nod 2 nA do 50 nA CMC 0,30 %\nod 50 nA do 200 nA CMC 0,20 %\nod 200 nA do 1 µA CMC 0,25 %\nPomiar bezpośredni pikoamperomierzem","reference":"MKE-ISS1, MKE-SRP.1","norm_bases":["MKE-ISS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni pikoamperomierzem od 1 nA do 2 nA CMC 0,40 % od 2 nA do 50 nA CMC 0,30 % od 50 nA do 200 nA CMC 0,20 % od 200 nA do 1 µA CMC 0,25 % Stejnosměrný proud / Zdroje, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé měření pikoampérmetrem 1 nA až 2 nA CMC 0,40 % 2 nA až 50 nA CMC 0,30 % 50 nA až 200 nA CMC 0,20 % 200 nA až 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1 Prad staly / zasilacze, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni pikoamperomierzem od 1 nA do 2 nA CMC 0,40 % od 2 nA do 50 nA CMC 0,30 % od 50 nA do 200 nA CMC 0,20 % od 200 nA do 1 µA CMC 0,25 % Stejnosmerny proud / Zdroje, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime mereni pikoampermetrem 1 nA az 2 nA CMC 0,40 % 2 nA az 50 nA CMC 0,30 % 50 nA az 200 nA CMC 0,20 % 200 nA az 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1","search_en":"DC current / Power supplies, calibrators, inspection instruments Calibration – electrical quantities Direct measurement with a picoammeter 1 nA to 2 nA CMC 0,40 % 2 nA to 50 nA CMC 0,30 % 50 nA to 200 nA CMC 0,20 % 200 nA to 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1","search_zh":"直流电流 / 电源、校准器、电气安装检测仪 校准 – 电学量 用皮安表直接测量 1 nA 至 2 nA CMC 0,40 % 2 nA 至 50 nA CMC 0,30 % 50 nA 至 200 nA CMC 0,20 % 200 nA 至 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"423c9c97024b4b03b540a850","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"DC current / Power supplies, calibrators, inspection instruments","test_object_zh":"直流电流 / 电源、校准器、电气安装检测仪","test_object_cs":"Stejnosměrný proud / Zdroje, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 µA do 20 µA","cmc":"0,011 %"},{"name":"","range":"od 20 µA do 20 mA","cmc":"0,0040 %"},{"name":"","range":"od 20 mA do 0,1 A","cmc":"0,011 %"},{"name":"","range":"od 0,1 A do 1 A","cmc":"0,0040 %"},{"name":"","range":"od 1 A do 2 A","cmc":"0,0060 %"},{"name":"","range":"od 2 A do 60 A","cmc":"0,011 %"},{"name":"","range":"od 60 A do 200 A","cmc":"0,015 %"},{"name":"","range":"od 200 A do 600 A","cmc":"0,040 %"},{"name":"","range":"od 600 A do 2000 A","cmc":"0,10 %"}],"parameters_en":[{"name":"","range":"1 µA to 20 µA","cmc":"0,011 %"},{"name":"","range":"20 µA to 20 mA","cmc":"0,0040 %"},{"name":"","range":"20 mA to 0,1 A","cmc":"0,011 %"},{"name":"","range":"0,1 A to 1 A","cmc":"0,0040 %"},{"name":"","range":"1 A to 2 A","cmc":"0,0060 %"},{"name":"","range":"2 A to 60 A","cmc":"0,011 %"},{"name":"","range":"60 A to 200 A","cmc":"0,015 %"},{"name":"","range":"200 A to 600 A","cmc":"0,040 %"},{"name":"","range":"600 A to 2000 A","cmc":"0,10 %"}],"parameters_zh":[{"name":"","range":"1 µA 至 20 µA","cmc":"0,011 %"},{"name":"","range":"20 µA 至 20 mA","cmc":"0,0040 %"},{"name":"","range":"20 mA 至 0,1 A","cmc":"0,011 %"},{"name":"","range":"0,1 A 至 1 A","cmc":"0,0040 %"},{"name":"","range":"1 A 至 2 A","cmc":"0,0060 %"},{"name":"","range":"2 A 至 60 A","cmc":"0,011 %"},{"name":"","range":"60 A 至 200 A","cmc":"0,015 %"},{"name":"","range":"200 A 至 600 A","cmc":"0,040 %"},{"name":"","range":"600 A 至 2000 A","cmc":"0,10 %"}],"parameters_cs":[{"name":"","range":"1 µA až 20 µA","cmc":"0,011 %"},{"name":"","range":"20 µA až 20 mA","cmc":"0,0040 %"},{"name":"","range":"20 mA až 0,1 A","cmc":"0,011 %"},{"name":"","range":"0,1 A až 1 A","cmc":"0,0040 %"},{"name":"","range":"1 A až 2 A","cmc":"0,0060 %"},{"name":"","range":"2 A až 60 A","cmc":"0,011 %"},{"name":"","range":"60 A až 200 A","cmc":"0,015 %"},{"name":"","range":"200 A až 600 A","cmc":"0,040 %"},{"name":"","range":"600 A až 2000 A","cmc":"0,10 %"}],"technique":"Pomiar bezpośredni multimetrem lub pomiar pośredni multimetrem z bocznikiem","technique_en":"Direct measurement with a multimeter or indirect measurement with a shunt multimeter","technique_zh":"用万用表直接测量或用带分流器的万用表间接测量","technique_cs":"Přímé měření multimetrem nebo nepřímé měření multimetrem s bočníkem","techniques":["Pomiar bezpośredni multimetrem lub pomiar pośredni multimetrem z bocznikiem"],"techniques_en":["Direct measurement with a multimeter or indirect measurement with a shunt multimeter"],"techniques_zh":["用万用表直接测量或用带分流器的万用表间接测量"],"techniques_cs":["Přímé měření multimetrem nebo nepřímé měření multimetrem s bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 µA do 20 µA CMC 0,011 %\nod 20 µA do 20 mA CMC 0,0040 %\nod 20 mA do 0,1 A CMC 0,011 %\nod 0,1 A do 1 A CMC 0,0040 %\nod 1 A do 2 A CMC 0,0060 %\nod 2 A do 60 A CMC 0,011 %\nod 60 A do 200 A CMC 0,015 %\nod 200 A do 600 A CMC 0,040 %\nod 600 A do 2000 A CMC 0,10 %\nPomiar bezpośredni multimetrem lub pomiar pośredni multimetrem z bocznikiem","reference":"MKE-ISS1, MKE-SRP.1","norm_bases":["MKE-ISS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem lub pomiar pośredni multimetrem z bocznikiem od 1 µA do 20 µA CMC 0,011 % od 20 µA do 20 mA CMC 0,0040 % od 20 mA do 0,1 A CMC 0,011 % od 0,1 A do 1 A CMC 0,0040 % od 1 A do 2 A CMC 0,0060 % od 2 A do 60 A CMC 0,011 % od 60 A do 200 A CMC 0,015 % od 200 A do 600 A CMC 0,040 % od 600 A do 2000 A CMC 0,10 % Stejnosměrný proud / Zdroje, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé měření multimetrem nebo nepřímé měření multimetrem s bočníkem 1 µA až 20 µA CMC 0,011 % 20 µA až 20 mA CMC 0,0040 % 20 mA až 0,1 A CMC 0,011 % 0,1 A až 1 A CMC 0,0040 % 1 A až 2 A CMC 0,0060 % 2 A až 60 A CMC 0,011 % 60 A až 200 A CMC 0,015 % 200 A až 600 A CMC 0,040 % 600 A až 2000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1 Prad staly / zasilacze, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem lub pomiar posredni multimetrem z bocznikiem od 1 µA do 20 µA CMC 0,011 % od 20 µA do 20 mA CMC 0,0040 % od 20 mA do 0,1 A CMC 0,011 % od 0,1 A do 1 A CMC 0,0040 % od 1 A do 2 A CMC 0,0060 % od 2 A do 60 A CMC 0,011 % od 60 A do 200 A CMC 0,015 % od 200 A do 600 A CMC 0,040 % od 600 A do 2000 A CMC 0,10 % Stejnosmerny proud / Zdroje, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime mereni multimetrem nebo neprime mereni multimetrem s bocnikem 1 µA az 20 µA CMC 0,011 % 20 µA az 20 mA CMC 0,0040 % 20 mA az 0,1 A CMC 0,011 % 0,1 A az 1 A CMC 0,0040 % 1 A az 2 A CMC 0,0060 % 2 A az 60 A CMC 0,011 % 60 A az 200 A CMC 0,015 % 200 A az 600 A CMC 0,040 % 600 A az 2000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1","search_en":"DC current / Power supplies, calibrators, inspection instruments Calibration – electrical quantities Direct measurement with a multimeter or indirect measurement with a shunt multimeter 1 µA to 20 µA CMC 0,011 % 20 µA to 20 mA CMC 0,0040 % 20 mA to 0,1 A CMC 0,011 % 0,1 A to 1 A CMC 0,0040 % 1 A to 2 A CMC 0,0060 % 2 A to 60 A CMC 0,011 % 60 A to 200 A CMC 0,015 % 200 A to 600 A CMC 0,040 % 600 A to 2000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1","search_zh":"直流电流 / 电源、校准器、电气安装检测仪 校准 – 电学量 用万用表直接测量或用带分流器的万用表间接测量 1 µA 至 20 µA CMC 0,011 % 20 µA 至 20 mA CMC 0,0040 % 20 mA 至 0,1 A CMC 0,011 % 0,1 A 至 1 A CMC 0,0040 % 1 A 至 2 A CMC 0,0060 % 2 A 至 60 A CMC 0,011 % 60 A 至 200 A CMC 0,015 % 200 A 至 600 A CMC 0,040 % 600 A 至 2000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f3b7ec7cfc8556a6020f786","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"7","test_object":"Prąd stały / amperomierze, multimetry, mierniki cęgowe, mierniki do badań instalacji elektrycznych","test_object_en":"DC current / Ammeters, multimeters, clamp meters, inspection instruments","test_object_zh":"直流电流 / 电流表、万用表、钳形表、电气安装检测仪","test_object_cs":"Stejnosměrný proud / Ampérmetry, multimetry, klešťová měřidla, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 nA do 2 nA","cmc":"0,40 %"},{"name":"","range":"od 2 nA do 50 nA","cmc":"0,30 %"},{"name":"","range":"od 50 nA do 200 nA","cmc":"0,20 %"},{"name":"","range":"od 200 nA do 1 µA","cmc":"0,25 %"}],"parameters_en":[{"name":"","range":"1 nA to 2 nA","cmc":"0,40 %"},{"name":"","range":"2 nA to 50 nA","cmc":"0,30 %"},{"name":"","range":"50 nA to 200 nA","cmc":"0,20 %"},{"name":"","range":"200 nA to 1 µA","cmc":"0,25 %"}],"parameters_zh":[{"name":"","range":"1 nA 至 2 nA","cmc":"0,40 %"},{"name":"","range":"2 nA 至 50 nA","cmc":"0,30 %"},{"name":"","range":"50 nA 至 200 nA","cmc":"0,20 %"},{"name":"","range":"200 nA 至 1 µA","cmc":"0,25 %"}],"parameters_cs":[{"name":"","range":"1 nA až 2 nA","cmc":"0,40 %"},{"name":"","range":"2 nA až 50 nA","cmc":"0,30 %"},{"name":"","range":"50 nA až 200 nA","cmc":"0,20 %"},{"name":"","range":"200 nA až 1 µA","cmc":"0,25 %"}],"technique":"Bezpośrednie porównanie z pikoamperomierzem","technique_en":"Direct comparison with a picoammeter","technique_zh":"与皮安表直接比较","technique_cs":"Přímé porovnání pikoampérmetrem","techniques":["Bezpośrednie porównanie z pikoamperomierzem"],"techniques_en":["Direct comparison with a picoammeter"],"techniques_zh":["与皮安表直接比较"],"techniques_cs":["Přímé porovnání pikoampérmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 nA do 2 nA CMC 0,40 %\nod 2 nA do 50 nA CMC 0,30 %\nod 50 nA do 200 nA CMC 0,20 %\nod 200 nA do 1 µA CMC 0,25 %\nBezpośrednie porównanie z pikoamperomierzem","reference":"MKE-ISS1, MKE-SRP.1","norm_bases":["MKE-ISS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / amperomierze, multimetry, mierniki cęgowe, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie porównanie z pikoamperomierzem od 1 nA do 2 nA CMC 0,40 % od 2 nA do 50 nA CMC 0,30 % od 50 nA do 200 nA CMC 0,20 % od 200 nA do 1 µA CMC 0,25 % Stejnosměrný proud / Ampérmetry, multimetry, klešťová měřidla, revizní přístroje Kalibrace – elektrické veličiny Přímé porovnání pikoampérmetrem 1 nA až 2 nA CMC 0,40 % 2 nA až 50 nA CMC 0,30 % 50 nA až 200 nA CMC 0,20 % 200 nA až 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1 Prad staly / amperomierze, multimetry, mierniki cegowe, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie porownanie z pikoamperomierzem od 1 nA do 2 nA CMC 0,40 % od 2 nA do 50 nA CMC 0,30 % od 50 nA do 200 nA CMC 0,20 % od 200 nA do 1 µA CMC 0,25 % Stejnosmerny proud / Ampermetry, multimetry, klestova meridla, revizni pristroje Kalibrace – elektricke veliciny Prime porovnani pikoampermetrem 1 nA az 2 nA CMC 0,40 % 2 nA az 50 nA CMC 0,30 % 50 nA az 200 nA CMC 0,20 % 200 nA az 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1","search_en":"DC current / Ammeters, multimeters, clamp meters, inspection instruments Calibration – electrical quantities Direct comparison with a picoammeter 1 nA to 2 nA CMC 0,40 % 2 nA to 50 nA CMC 0,30 % 50 nA to 200 nA CMC 0,20 % 200 nA to 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1","search_zh":"直流电流 / 电流表、万用表、钳形表、电气安装检测仪 校准 – 电学量 与皮安表直接比较 1 nA 至 2 nA CMC 0,40 % 2 nA 至 50 nA CMC 0,30 % 50 nA 至 200 nA CMC 0,20 % 200 nA 至 1 µA CMC 0,25 % MKE-ISS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5e508f0f83dfa58f8b269d99","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"7","test_object":"Prąd stały / amperomierze, multimetry, mierniki cęgowe, mierniki do badań instalacji elektrycznych","test_object_en":"DC current / Ammeters, multimeters, clamp meters, inspection instruments","test_object_zh":"直流电流 / 电流表、万用表、钳形表、电气安装检测仪","test_object_cs":"Stejnosměrný proud / Ampérmetry, multimetry, klešťová měřidla, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 µA do 20 µA","cmc":"0,011 %"},{"name":"","range":"od 20 µA do 20 mA","cmc":"0,0040 %"},{"name":"","range":"od 20 mA do 0,1 A","cmc":"0,011 %"},{"name":"","range":"od 0,1 A do 1 A","cmc":"0,0040 %"},{"name":"","range":"od 1 A do 2 A","cmc":"0,0060 %"},{"name":"","range":"od 2 A do 60 A","cmc":"0,011 %"},{"name":"","range":"od 60 A do 200 A","cmc":"0,015 %"},{"name":"","range":"od 200 A do 600 A","cmc":"0,040 %"},{"name":"","range":"od 600 A do 2 000 A","cmc":"0,10 %"}],"parameters_en":[{"name":"","range":"1 µA to 20 µA","cmc":"0,011 %"},{"name":"","range":"20 µA to 20 mA","cmc":"0,0040 %"},{"name":"","range":"20 mA to 0,1 A","cmc":"0,011 %"},{"name":"","range":"0,1 A to 1 A","cmc":"0,0040 %"},{"name":"","range":"1 A to 2 A","cmc":"0,0060 %"},{"name":"","range":"2 A to 60 A","cmc":"0,011 %"},{"name":"","range":"60 A to 200 A","cmc":"0,015 %"},{"name":"","range":"200 A to 600 A","cmc":"0,040 %"},{"name":"","range":"600 A to 2 000 A","cmc":"0,10 %"}],"parameters_zh":[{"name":"","range":"1 µA 至 20 µA","cmc":"0,011 %"},{"name":"","range":"20 µA 至 20 mA","cmc":"0,0040 %"},{"name":"","range":"20 mA 至 0,1 A","cmc":"0,011 %"},{"name":"","range":"0,1 A 至 1 A","cmc":"0,0040 %"},{"name":"","range":"1 A 至 2 A","cmc":"0,0060 %"},{"name":"","range":"2 A 至 60 A","cmc":"0,011 %"},{"name":"","range":"60 A 至 200 A","cmc":"0,015 %"},{"name":"","range":"200 A 至 600 A","cmc":"0,040 %"},{"name":"","range":"600 A 至 2 000 A","cmc":"0,10 %"}],"parameters_cs":[{"name":"","range":"1 µA až 20 µA","cmc":"0,011 %"},{"name":"","range":"20 µA až 20 mA","cmc":"0,0040 %"},{"name":"","range":"20 mA až 0,1 A","cmc":"0,011 %"},{"name":"","range":"0,1 A až 1 A","cmc":"0,0040 %"},{"name":"","range":"1 A až 2 A","cmc":"0,0060 %"},{"name":"","range":"2 A až 60 A","cmc":"0,011 %"},{"name":"","range":"60 A až 200 A","cmc":"0,015 %"},{"name":"","range":"200 A až 600 A","cmc":"0,040 %"},{"name":"","range":"600 A až 2 000 A","cmc":"0,10 %"}],"technique":"Bezpośrednie porównanie z multimetrem lub pośrednie porównanie z multimetrem z bocznikiem","technique_en":"Direct comparison using a multimeter or indirect comparison using a shunt multimeter","technique_zh":"与万用表直接比较或与带分流器的万用表间接比较","technique_cs":"Přímé porovnání multimetrem nebo nepřímé porovnání multimetrem s bočníkem","techniques":["Bezpośrednie porównanie z multimetrem lub pośrednie porównanie z multimetrem z bocznikiem"],"techniques_en":["Direct comparison using a multimeter or indirect comparison using a shunt multimeter"],"techniques_zh":["与万用表直接比较或与带分流器的万用表间接比较"],"techniques_cs":["Přímé porovnání multimetrem nebo nepřímé porovnání multimetrem s bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 µA do 20 µA CMC 0,011 %\nod 20 µA do 20 mA CMC 0,0040 %\nod 20 mA do 0,1 A CMC 0,011 %\nod 0,1 A do 1 A CMC 0,0040 %\nod 1 A do 2 A CMC 0,0060 %\nod 2 A do 60 A CMC 0,011 %\nod 60 A do 200 A CMC 0,015 %\nod 200 A do 600 A CMC 0,040 %\nod 600 A do 2 000 A CMC 0,10 %\nBezpośrednie porównanie z multimetrem lub pośrednie porównanie z multimetrem z bocznikiem","reference":"MKE-ISS1, MKE-SRP.1","norm_bases":["MKE-ISS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / amperomierze, multimetry, mierniki cęgowe, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie porównanie z multimetrem lub pośrednie porównanie z multimetrem z bocznikiem od 1 µA do 20 µA CMC 0,011 % od 20 µA do 20 mA CMC 0,0040 % od 20 mA do 0,1 A CMC 0,011 % od 0,1 A do 1 A CMC 0,0040 % od 1 A do 2 A CMC 0,0060 % od 2 A do 60 A CMC 0,011 % od 60 A do 200 A CMC 0,015 % od 200 A do 600 A CMC 0,040 % od 600 A do 2 000 A CMC 0,10 % Stejnosměrný proud / Ampérmetry, multimetry, klešťová měřidla, revizní přístroje Kalibrace – elektrické veličiny Přímé porovnání multimetrem nebo nepřímé porovnání multimetrem s bočníkem 1 µA až 20 µA CMC 0,011 % 20 µA až 20 mA CMC 0,0040 % 20 mA až 0,1 A CMC 0,011 % 0,1 A až 1 A CMC 0,0040 % 1 A až 2 A CMC 0,0060 % 2 A až 60 A CMC 0,011 % 60 A až 200 A CMC 0,015 % 200 A až 600 A CMC 0,040 % 600 A až 2 000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1 Prad staly / amperomierze, multimetry, mierniki cegowe, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie porownanie z multimetrem lub posrednie porownanie z multimetrem z bocznikiem od 1 µA do 20 µA CMC 0,011 % od 20 µA do 20 mA CMC 0,0040 % od 20 mA do 0,1 A CMC 0,011 % od 0,1 A do 1 A CMC 0,0040 % od 1 A do 2 A CMC 0,0060 % od 2 A do 60 A CMC 0,011 % od 60 A do 200 A CMC 0,015 % od 200 A do 600 A CMC 0,040 % od 600 A do 2 000 A CMC 0,10 % Stejnosmerny proud / Ampermetry, multimetry, klestova meridla, revizni pristroje Kalibrace – elektricke veliciny Prime porovnani multimetrem nebo neprime porovnani multimetrem s bocnikem 1 µA az 20 µA CMC 0,011 % 20 µA az 20 mA CMC 0,0040 % 20 mA az 0,1 A CMC 0,011 % 0,1 A az 1 A CMC 0,0040 % 1 A az 2 A CMC 0,0060 % 2 A az 60 A CMC 0,011 % 60 A az 200 A CMC 0,015 % 200 A az 600 A CMC 0,040 % 600 A az 2 000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1","search_en":"DC current / Ammeters, multimeters, clamp meters, inspection instruments Calibration – electrical quantities Direct comparison using a multimeter or indirect comparison using a shunt multimeter 1 µA to 20 µA CMC 0,011 % 20 µA to 20 mA CMC 0,0040 % 20 mA to 0,1 A CMC 0,011 % 0,1 A to 1 A CMC 0,0040 % 1 A to 2 A CMC 0,0060 % 2 A to 60 A CMC 0,011 % 60 A to 200 A CMC 0,015 % 200 A to 600 A CMC 0,040 % 600 A to 2 000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1","search_zh":"直流电流 / 电流表、万用表、钳形表、电气安装检测仪 校准 – 电学量 与万用表直接比较或与带分流器的万用表间接比较 1 µA 至 20 µA CMC 0,011 % 20 µA 至 20 mA CMC 0,0040 % 20 mA 至 0,1 A CMC 0,011 % 0,1 A 至 1 A CMC 0,0040 % 1 A 至 2 A CMC 0,0060 % 2 A 至 60 A CMC 0,011 % 60 A 至 200 A CMC 0,015 % 200 A 至 600 A CMC 0,040 % 600 A 至 2 000 A CMC 0,10 % MKE-ISS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd9a15c431451aedcd06b58c","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"8","test_object":"Prąd stały / amperomierze, multimetry, mierniki cęgowe, mierniki do badań instalacji elektrycznych","test_object_en":"DC current / Ammeters, multimeters, clamp meters, inspection instruments","test_object_zh":"直流电流 / 电流表、万用表、钳形表、电气安装检测仪","test_object_cs":"Stejnosměrný proud / Ampérmetry, multimetry, klešťová měřidla, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 22 µA do 100 µA","cmc":"0,040 %"},{"name":"","range":"od 100 µA do 2,2 mA","cmc":"0,0090 %"},{"name":"","range":"od 2,2 mA do 22 mA","cmc":"0,0070 %"},{"name":"","range":"od 22 mA do 220 mA","cmc":"0,0090 %"},{"name":"","range":"od 220 mA do 2,2 A","cmc":"0,016 %"}],"parameters_en":[{"name":"","range":"22 µA to 100 µA","cmc":"0,040 %"},{"name":"","range":"100 µA to 2,2 mA","cmc":"0,0090 %"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0070 %"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0090 %"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,016 %"}],"parameters_zh":[{"name":"","range":"22 µA 至 100 µA","cmc":"0,040 %"},{"name":"","range":"100 µA 至 2,2 mA","cmc":"0,0090 %"},{"name":"","range":"2,2 mA 至 22 mA","cmc":"0,0070 %"},{"name":"","range":"22 mA 至 220 mA","cmc":"0,0090 %"},{"name":"","range":"220 mA 至 2,2 A","cmc":"0,016 %"}],"parameters_cs":[{"name":"","range":"22 µA až 100 µA","cmc":"0,040 %"},{"name":"","range":"100 µA až 2,2 mA","cmc":"0,0090 %"},{"name":"","range":"2,2 mA až 22 mA","cmc":"0,0070 %"},{"name":"","range":"22 mA až 220 mA","cmc":"0,0090 %"},{"name":"","range":"220 mA až 2,2 A","cmc":"0,016 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 22 µA do 100 µA CMC 0,040 %\nod 100 µA do 2,2 mA CMC 0,0090 %\nod 2,2 mA do 22 mA CMC 0,0070 %\nod 22 mA do 220 mA CMC 0,0090 %\nod 220 mA do 2,2 A CMC 0,016 %\nBezpośrednie generowanie kalibratorem","reference":"MKE-ISS1, MKE-SRP.1","norm_bases":["MKE-ISS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / amperomierze, multimetry, mierniki cęgowe, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 22 µA do 100 µA CMC 0,040 % od 100 µA do 2,2 mA CMC 0,0090 % od 2,2 mA do 22 mA CMC 0,0070 % od 22 mA do 220 mA CMC 0,0090 % od 220 mA do 2,2 A CMC 0,016 % Stejnosměrný proud / Ampérmetry, multimetry, klešťová měřidla, revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 22 µA až 100 µA CMC 0,040 % 100 µA až 2,2 mA CMC 0,0090 % 2,2 mA až 22 mA CMC 0,0070 % 22 mA až 220 mA CMC 0,0090 % 220 mA až 2,2 A CMC 0,016 % MKE-ISS1, MKE-SRP.1 Prad staly / amperomierze, multimetry, mierniki cegowe, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 22 µA do 100 µA CMC 0,040 % od 100 µA do 2,2 mA CMC 0,0090 % od 2,2 mA do 22 mA CMC 0,0070 % od 22 mA do 220 mA CMC 0,0090 % od 220 mA do 2,2 A CMC 0,016 % Stejnosmerny proud / Ampermetry, multimetry, klestova meridla, revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 22 µA az 100 µA CMC 0,040 % 100 µA az 2,2 mA CMC 0,0090 % 2,2 mA az 22 mA CMC 0,0070 % 22 mA az 220 mA CMC 0,0090 % 220 mA az 2,2 A CMC 0,016 % MKE-ISS1, MKE-SRP.1","search_en":"DC current / Ammeters, multimeters, clamp meters, inspection instruments Calibration – electrical quantities Direct generation with a calibrator 22 µA to 100 µA CMC 0,040 % 100 µA to 2,2 mA CMC 0,0090 % 2,2 mA to 22 mA CMC 0,0070 % 22 mA to 220 mA CMC 0,0090 % 220 mA to 2,2 A CMC 0,016 % MKE-ISS1, MKE-SRP.1","search_zh":"直流电流 / 电流表、万用表、钳形表、电气安装检测仪 校准 – 电学量 用校准器直接产生 22 µA 至 100 µA CMC 0,040 % 100 µA 至 2,2 mA CMC 0,0090 % 2,2 mA 至 22 mA CMC 0,0070 % 22 mA 至 220 mA CMC 0,0090 % 220 mA 至 2,2 A CMC 0,016 % MKE-ISS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd54342d21d5f03ce687fbe0","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"9","test_object":"Prąd stały / mierniki cęgowe, mierniki do badań instalacji elektrycznych","test_object_en":"DC current / Clamp meters, inspection instruments","test_object_zh":"直流电流 / 钳形表、电气安装检测仪","test_object_cs":"Stejnosměrný proud / Klešťová měřidla, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 200 A do 2000 A","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"200 A to 2000 A","cmc":"0,2 %"}],"parameters_zh":[{"name":"","range":"200 A 至 2000 A","cmc":"0,2 %"}],"parameters_cs":[{"name":"","range":"200 A až 2000 A","cmc":"0,2 %"}],"technique":"Pomiar pośredni z cewką prądową","technique_en":"Indirect measurement with a current coil","technique_zh":"用电流线圈间接测量","technique_cs":"Nepřímé měření s proudovou cívkou","techniques":["Pomiar pośredni z cewką prądową"],"techniques_en":["Indirect measurement with a current coil"],"techniques_zh":["用电流线圈间接测量"],"techniques_cs":["Nepřímé měření s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 200 A do 2000 A CMC 0,2 %\nPomiar pośredni z cewką prądową","reference":"MKE-ISS1, MKE-SRP.1","norm_bases":["MKE-ISS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki cęgowe, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar pośredni z cewką prądową od 200 A do 2000 A CMC 0,2 % Stejnosměrný proud / Klešťová měřidla, revizní přístroje Kalibrace – elektrické veličiny Nepřímé měření s proudovou cívkou 200 A až 2000 A CMC 0,2 % MKE-ISS1, MKE-SRP.1 Prad staly / mierniki cegowe, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar posredni z cewka pradowa od 200 A do 2000 A CMC 0,2 % Stejnosmerny proud / Klestova meridla, revizni pristroje Kalibrace – elektricke veliciny Neprime mereni s proudovou civkou 200 A az 2000 A CMC 0,2 % MKE-ISS1, MKE-SRP.1","search_en":"DC current / Clamp meters, inspection instruments Calibration – electrical quantities Indirect measurement with a current coil 200 A to 2000 A CMC 0,2 % MKE-ISS1, MKE-SRP.1","search_zh":"直流电流 / 钳形表、电气安装检测仪 校准 – 电学量 用电流线圈间接测量 200 A 至 2000 A CMC 0,2 % MKE-ISS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f3561e0c719c0c131f22cab0","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"10","test_object":"Prąd przemienny / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"AC current / Power supplies, calibrators, inspection instruments","test_object_zh":"交流电流 / 电源、校准器、电气安装检测仪","test_object_cs":"Střídavý proud / Zdroje, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 10 µA do 200 µA","cmc":"0,050 % + 22 nA"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"10 µA to 200 µA","cmc":"0,050 % + 22 nA"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"10 µA 至 200 µA","cmc":"0,050 % + 22 nA"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"10 µA až 200 µA","cmc":"0,050 % + 22 nA"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n40 Hz do 1 kHz od 10 µA do 200 µA CMC 0,050 % + 22 nA\nPomiar bezpośredni multimetrem","reference":"MKE-IST1","norm_bases":["MKE-IST1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 40 Hz do 1 kHz od 10 µA do 200 µA CMC 0,050 % + 22 nA Střídavý proud / Zdroje, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé měření multimetrem 40 Hz až 1 kHz 10 µA až 200 µA CMC 0,050 % + 22 nA MKE-IST1 Prad przemienny / zasilacze, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 40 Hz do 1 kHz od 10 µA do 200 µA CMC 0,050 % + 22 nA Stridavy proud / Zdroje, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime mereni multimetrem 40 Hz az 1 kHz 10 µA az 200 µA CMC 0,050 % + 22 nA MKE-IST1","search_en":"AC current / Power supplies, calibrators, inspection instruments Calibration – electrical quantities Direct measurement using a multimeter 40 Hz to 1 kHz 10 µA to 200 µA CMC 0,050 % + 22 nA MKE-IST1","search_zh":"交流电流 / 电源、校准器、电气安装检测仪 校准 – 电学量 用万用表直接测量 40 Hz 至 1 kHz 10 µA 至 200 µA CMC 0,050 % + 22 nA MKE-IST1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2a9658e3c659f595bc2a041","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"10","test_object":"Prąd przemienny / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"AC current / Power supplies, calibrators, inspection instruments","test_object_zh":"交流电流 / 电源、校准器、电气安装检测仪","test_object_cs":"Střídavý proud / Zdroje, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 200 µA do 2 mA","cmc":"0,035 % + 0,22 µA"},{"name":"40 Hz do 1 kHz","range":"od 2 mA do 20 mA","cmc":"0,038 % + 2,2 µA"},{"name":"40 Hz do 1 kHz","range":"od 20 mA do 200 mA","cmc":"0,037 % + 20 µA"},{"name":"40 Hz do 1 kHz","range":"od 200 mA do 2 A","cmc":"0,082 % + 0,2 mA"},{"name":"40 Hz do 1 kHz","range":"od 2 A do 20 A","cmc":"0,12 % + 2 mA"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"200 µA to 2 mA","cmc":"0,035 % + 0,22 µA"},{"name":"40 Hz to 1 kHz","range":"2 mA to 20 mA","cmc":"0,038 % + 2,2 µA"},{"name":"40 Hz to 1 kHz","range":"20 mA to 200 mA","cmc":"0,037 % + 20 µA"},{"name":"40 Hz to 1 kHz","range":"200 mA to 2 A","cmc":"0,082 % + 0,2 mA"},{"name":"40 Hz to 1 kHz","range":"2 A to 20 A","cmc":"0,12 % + 2 mA"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"200 µA 至 2 mA","cmc":"0,035 % + 0,22 µA"},{"name":"40 Hz 至 1 kHz","range":"2 mA 至 20 mA","cmc":"0,038 % + 2,2 µA"},{"name":"40 Hz 至 1 kHz","range":"20 mA 至 200 mA","cmc":"0,037 % + 20 µA"},{"name":"40 Hz 至 1 kHz","range":"200 mA 至 2 A","cmc":"0,082 % + 0,2 mA"},{"name":"40 Hz 至 1 kHz","range":"2 A 至 20 A","cmc":"0,12 % + 2 mA"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"200 µA až 2 mA","cmc":"0,035 % + 0,22 µA"},{"name":"40 Hz až 1 kHz","range":"2 mA až 20 mA","cmc":"0,038 % + 2,2 µA"},{"name":"40 Hz až 1 kHz","range":"20 mA až 200 mA","cmc":"0,037 % + 20 µA"},{"name":"40 Hz až 1 kHz","range":"200 mA až 2 A","cmc":"0,082 % + 0,2 mA"},{"name":"40 Hz až 1 kHz","range":"2 A až 20 A","cmc":"0,12 % + 2 mA"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 200 µA do 2 mA CMC 0,035 % + 0,22 µA\n40 Hz do 1 kHz od 2 mA do 20 mA CMC 0,038 % + 2,2 µA\n40 Hz do 1 kHz od 20 mA do 200 mA CMC 0,037 % + 20 µA\n40 Hz do 1 kHz od 200 mA do 2 A CMC 0,082 % + 0,2 mA\n40 Hz do 1 kHz od 2 A do 20 A CMC 0,12 % + 2 mA\nPomiar bezpośredni multimetrem","reference":"MKE-IST1, MKE-SRP.1","norm_bases":["MKE-IST1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 40 Hz do 1 kHz od 200 µA do 2 mA CMC 0,035 % + 0,22 µA 40 Hz do 1 kHz od 2 mA do 20 mA CMC 0,038 % + 2,2 µA 40 Hz do 1 kHz od 20 mA do 200 mA CMC 0,037 % + 20 µA 40 Hz do 1 kHz od 200 mA do 2 A CMC 0,082 % + 0,2 mA 40 Hz do 1 kHz od 2 A do 20 A CMC 0,12 % + 2 mA Střídavý proud / Zdroje, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé měření multimetrem 40 Hz až 1 kHz 200 µA až 2 mA CMC 0,035 % + 0,22 µA 40 Hz až 1 kHz 2 mA až 20 mA CMC 0,038 % + 2,2 µA 40 Hz až 1 kHz 20 mA až 200 mA CMC 0,037 % + 20 µA 40 Hz až 1 kHz 200 mA až 2 A CMC 0,082 % + 0,2 mA 40 Hz až 1 kHz 2 A až 20 A CMC 0,12 % + 2 mA MKE-IST1, MKE-SRP.1 Prad przemienny / zasilacze, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 40 Hz do 1 kHz od 200 µA do 2 mA CMC 0,035 % + 0,22 µA 40 Hz do 1 kHz od 2 mA do 20 mA CMC 0,038 % + 2,2 µA 40 Hz do 1 kHz od 20 mA do 200 mA CMC 0,037 % + 20 µA 40 Hz do 1 kHz od 200 mA do 2 A CMC 0,082 % + 0,2 mA 40 Hz do 1 kHz od 2 A do 20 A CMC 0,12 % + 2 mA Stridavy proud / Zdroje, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime mereni multimetrem 40 Hz az 1 kHz 200 µA az 2 mA CMC 0,035 % + 0,22 µA 40 Hz az 1 kHz 2 mA az 20 mA CMC 0,038 % + 2,2 µA 40 Hz az 1 kHz 20 mA az 200 mA CMC 0,037 % + 20 µA 40 Hz az 1 kHz 200 mA az 2 A CMC 0,082 % + 0,2 mA 40 Hz az 1 kHz 2 A az 20 A CMC 0,12 % + 2 mA MKE-IST1, MKE-SRP.1","search_en":"AC current / Power supplies, calibrators, inspection instruments Calibration – electrical quantities Direct measurement using a multimeter 40 Hz to 1 kHz 200 µA to 2 mA CMC 0,035 % + 0,22 µA 40 Hz to 1 kHz 2 mA to 20 mA CMC 0,038 % + 2,2 µA 40 Hz to 1 kHz 20 mA to 200 mA CMC 0,037 % + 20 µA 40 Hz to 1 kHz 200 mA to 2 A CMC 0,082 % + 0,2 mA 40 Hz to 1 kHz 2 A to 20 A CMC 0,12 % + 2 mA MKE-IST1, MKE-SRP.1","search_zh":"交流电流 / 电源、校准器、电气安装检测仪 校准 – 电学量 用万用表直接测量 40 Hz 至 1 kHz 200 µA 至 2 mA CMC 0,035 % + 0,22 µA 40 Hz 至 1 kHz 2 mA 至 20 mA CMC 0,038 % + 2,2 µA 40 Hz 至 1 kHz 20 mA 至 200 mA CMC 0,037 % + 20 µA 40 Hz 至 1 kHz 200 mA 至 2 A CMC 0,082 % + 0,2 mA 40 Hz 至 1 kHz 2 A 至 20 A CMC 0,12 % + 2 mA MKE-IST1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d8d3ca9975fc9a512d79681","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"10","test_object":"Prąd przemienny / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"AC current / Power supplies, calibrators, inspection instruments","test_object_zh":"交流电流 / 电源、校准器、电气安装检测仪","test_object_cs":"Střídavý proud / Zdroje, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 do 60 Hz","range":"od 200 mA do 200 A","cmc":"0,10 %"},{"name":"50 Hz","range":"od 200 A do 2 500 A","cmc":"0,20 %"}],"parameters_en":[{"name":"50 to 60 Hz","range":"200 mA to 200 A","cmc":"0,10 %"},{"name":"50 Hz","range":"200 A to 2 500 A","cmc":"0,20 %"}],"parameters_zh":[{"name":"50 至 60 Hz","range":"200 mA 至 200 A","cmc":"0,10 %"},{"name":"50 Hz","range":"200 A 至 2 500 A","cmc":"0,20 %"}],"parameters_cs":[{"name":"50 až 60 Hz","range":"200 mA až 200 A","cmc":"0,10 %"},{"name":"50 Hz","range":"200 A až 2 500 A","cmc":"0,20 %"}],"technique":"Pomiar pośredni przekładnikiem prądowym i multimetrem","technique_en":"Indirect measurement using a current transformer and multimeter","technique_zh":"用电流互感器和万用表间接测量","technique_cs":"Nepřímé měření proudovým transformátorem a multimetrem","techniques":["Pomiar pośredni przekładnikiem prądowym i multimetrem"],"techniques_en":["Indirect measurement using a current transformer and multimeter"],"techniques_zh":["用电流互感器和万用表间接测量"],"techniques_cs":["Nepřímé měření proudovým transformátorem a multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 do 60 Hz od 200 mA do 200 A CMC 0,10 %\n50 Hz od 200 A do 2 500 A CMC 0,20 %\nPomiar pośredni przekładnikiem prądowym i multimetrem","reference":"MKE-IST1, MKE-SRP.1","norm_bases":["MKE-IST1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / zasilacze, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar pośredni przekładnikiem prądowym i multimetrem 50 do 60 Hz od 200 mA do 200 A CMC 0,10 % 50 Hz od 200 A do 2 500 A CMC 0,20 % Střídavý proud / Zdroje, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Nepřímé měření proudovým transformátorem a multimetrem 50 až 60 Hz 200 mA až 200 A CMC 0,10 % 50 Hz 200 A až 2 500 A CMC 0,20 % MKE-IST1, MKE-SRP.1 Prad przemienny / zasilacze, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar posredni przekladnikiem pradowym i multimetrem 50 do 60 Hz od 200 mA do 200 A CMC 0,10 % 50 Hz od 200 A do 2 500 A CMC 0,20 % Stridavy proud / Zdroje, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Neprime mereni proudovym transformatorem a multimetrem 50 az 60 Hz 200 mA az 200 A CMC 0,10 % 50 Hz 200 A az 2 500 A CMC 0,20 % MKE-IST1, MKE-SRP.1","search_en":"AC current / Power supplies, calibrators, inspection instruments Calibration – electrical quantities Indirect measurement using a current transformer and multimeter 50 to 60 Hz 200 mA to 200 A CMC 0,10 % 50 Hz 200 A to 2 500 A CMC 0,20 % MKE-IST1, MKE-SRP.1","search_zh":"交流电流 / 电源、校准器、电气安装检测仪 校准 – 电学量 用电流互感器和万用表间接测量 50 至 60 Hz 200 mA 至 200 A CMC 0,10 % 50 Hz 200 A 至 2 500 A CMC 0,20 % MKE-IST1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eec416ed9eb5efa26d76ccf1","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"10","test_object":"Prąd przemienny / amperomierze, multimetry, mierniki do badań instalacji elektrycznych","test_object_en":"AC current / Ammeters, multimeters, inspection instruments","test_object_zh":"交流电流 / 电流表、万用表、电气安装检测仪","test_object_cs":"Střídavý proud / Ampérmetry, multimetry, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 22 µA do 100 µA","cmc":"0,060 %"},{"name":"40 Hz do 1 kHz","range":"od 100 µA do 5 mA","cmc":"0,035 %"},{"name":"40 Hz do 1 kHz","range":"od 5 mA do 22 mA","cmc":"0,025 %"},{"name":"40 Hz do 1 kHz","range":"od 22 mA do 220 mA","cmc":"0,028 %"},{"name":"40 Hz do 1 kHz","range":"od 220 mA do 2,2 A","cmc":"0,050 %"},{"name":"40 Hz do 1 kHz","range":"od 2,2 A do 20 A","cmc":"0,06 % + 1 mA"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"22 µA to 100 µA","cmc":"0,060 %"},{"name":"40 Hz to 1 kHz","range":"100 µA to 5 mA","cmc":"0,035 %"},{"name":"40 Hz to 1 kHz","range":"5 mA to 22 mA","cmc":"0,025 %"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"0,028 %"},{"name":"40 Hz to 1 kHz","range":"220 mA to 2,2 A","cmc":"0,050 %"},{"name":"40 Hz to 1 kHz","range":"2,2 A to 20 A","cmc":"0,06 % + 1 mA"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"22 µA 至 100 µA","cmc":"0,060 %"},{"name":"40 Hz 至 1 kHz","range":"100 µA 至 5 mA","cmc":"0,035 %"},{"name":"40 Hz 至 1 kHz","range":"5 mA 至 22 mA","cmc":"0,025 %"},{"name":"40 Hz 至 1 kHz","range":"22 mA 至 220 mA","cmc":"0,028 %"},{"name":"40 Hz 至 1 kHz","range":"220 mA 至 2,2 A","cmc":"0,050 %"},{"name":"40 Hz 至 1 kHz","range":"2,2 A 至 20 A","cmc":"0,06 % + 1 mA"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"22 µA až 100 µA","cmc":"0,060 %"},{"name":"40 Hz až 1 kHz","range":"100 µA až 5 mA","cmc":"0,035 %"},{"name":"40 Hz až 1 kHz","range":"5 mA až 22 mA","cmc":"0,025 %"},{"name":"40 Hz až 1 kHz","range":"22 mA až 220 mA","cmc":"0,028 %"},{"name":"40 Hz až 1 kHz","range":"220 mA až 2,2 A","cmc":"0,050 %"},{"name":"40 Hz až 1 kHz","range":"2,2 A až 20 A","cmc":"0,06 % + 1 mA"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 22 µA do 100 µA CMC 0,060 %\n40 Hz do 1 kHz od 100 µA do 5 mA CMC 0,035 %\n40 Hz do 1 kHz od 5 mA do 22 mA CMC 0,025 %\n40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,028 %\n40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,050 %\n40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,06 % + 1 mA\nBezpośrednie generowanie kalibratorem","reference":"MKE-IST1, MKE-SRP.1","norm_bases":["MKE-IST1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / amperomierze, multimetry, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 40 Hz do 1 kHz od 22 µA do 100 µA CMC 0,060 % 40 Hz do 1 kHz od 100 µA do 5 mA CMC 0,035 % 40 Hz do 1 kHz od 5 mA do 22 mA CMC 0,025 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,028 % 40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,050 % 40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,06 % + 1 mA Střídavý proud / Ampérmetry, multimetry, revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 40 Hz až 1 kHz 22 µA až 100 µA CMC 0,060 % 40 Hz až 1 kHz 100 µA až 5 mA CMC 0,035 % 40 Hz až 1 kHz 5 mA až 22 mA CMC 0,025 % 40 Hz až 1 kHz 22 mA až 220 mA CMC 0,028 % 40 Hz až 1 kHz 220 mA až 2,2 A CMC 0,050 % 40 Hz až 1 kHz 2,2 A až 20 A CMC 0,06 % + 1 mA MKE-IST1, MKE-SRP.1 Prad przemienny / amperomierze, multimetry, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 40 Hz do 1 kHz od 22 µA do 100 µA CMC 0,060 % 40 Hz do 1 kHz od 100 µA do 5 mA CMC 0,035 % 40 Hz do 1 kHz od 5 mA do 22 mA CMC 0,025 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,028 % 40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,050 % 40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,06 % + 1 mA Stridavy proud / Ampermetry, multimetry, revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 40 Hz az 1 kHz 22 µA az 100 µA CMC 0,060 % 40 Hz az 1 kHz 100 µA az 5 mA CMC 0,035 % 40 Hz az 1 kHz 5 mA az 22 mA CMC 0,025 % 40 Hz az 1 kHz 22 mA az 220 mA CMC 0,028 % 40 Hz az 1 kHz 220 mA az 2,2 A CMC 0,050 % 40 Hz az 1 kHz 2,2 A az 20 A CMC 0,06 % + 1 mA MKE-IST1, MKE-SRP.1","search_en":"AC current / Ammeters, multimeters, inspection instruments Calibration – electrical quantities Direct generation with a calibrator 40 Hz to 1 kHz 22 µA to 100 µA CMC 0,060 % 40 Hz to 1 kHz 100 µA to 5 mA CMC 0,035 % 40 Hz to 1 kHz 5 mA to 22 mA CMC 0,025 % 40 Hz to 1 kHz 22 mA to 220 mA CMC 0,028 % 40 Hz to 1 kHz 220 mA to 2,2 A CMC 0,050 % 40 Hz to 1 kHz 2,2 A to 20 A CMC 0,06 % + 1 mA MKE-IST1, MKE-SRP.1","search_zh":"交流电流 / 电流表、万用表、电气安装检测仪 校准 – 电学量 用校准器直接产生 40 Hz 至 1 kHz 22 µA 至 100 µA CMC 0,060 % 40 Hz 至 1 kHz 100 µA 至 5 mA CMC 0,035 % 40 Hz 至 1 kHz 5 mA 至 22 mA CMC 0,025 % 40 Hz 至 1 kHz 22 mA 至 220 mA CMC 0,028 % 40 Hz 至 1 kHz 220 mA 至 2,2 A CMC 0,050 % 40 Hz 至 1 kHz 2,2 A 至 20 A CMC 0,06 % + 1 mA MKE-IST1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"986a22414d9e0d9d85f9713f","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"11","test_object":"Moc prądu stałego / watomierze, analizatory sieci, mierniki do badań instalacji elektrycznych (30 V do 500 V, 0,02 A do 200 A)","test_object_en":"DC power / Wattmeters, network analyzers, inspection instruments (30 V to 500 V, 0.02 A to 200 A)","test_object_zh":"直流功率 / 功率表、电网分析仪、电气安装检测仪（30 V 至 500 V，0,02 A 至 200 A）","test_object_cs":"Stejnosměrný výkon / Wattmetry, analyzátory sítí, revizní přístroje (30 V až 500 V, 0,02 A až 200 A)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 W do 105 kW","cmc":"0,060 %"}],"parameters_en":[{"name":"","range":"1 W to 105 kW","cmc":"0,060 %"}],"parameters_zh":[{"name":"","range":"1 W 至 105 kW","cmc":"0,060 %"}],"parameters_cs":[{"name":"","range":"1 W až 105 kW","cmc":"0,060 %"}],"technique":"Pomiar bezpośredni multimetrami lub pomiar pośredni bocznikiem i multimetrem","technique_en":"Direct measurement with multimeters or with a shunt and multimeter","technique_zh":"用万用表直接测量或用分流器和万用表间接测量","technique_cs":"Přímé měření multimetry nebo nepřímé měření bočníkem a multimetrem","techniques":["Pomiar bezpośredni multimetrami lub pomiar pośredni bocznikiem i multimetrem"],"techniques_en":["Direct measurement with multimeters or with a shunt and multimeter"],"techniques_zh":["用万用表直接测量或用分流器和万用表间接测量"],"techniques_cs":["Přímé měření multimetry nebo nepřímé měření bočníkem a multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 W do 105 kW CMC 0,060 %\nPomiar bezpośredni multimetrami lub pomiar pośredni bocznikiem i multimetrem","reference":"MKE-W1","norm_bases":["MKE-W1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / watomierze, analizatory sieci, mierniki do badań instalacji elektrycznych (30 V do 500 V, 0,02 A do 200 A) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrami lub pomiar pośredni bocznikiem i multimetrem od 1 W do 105 kW CMC 0,060 % Stejnosměrný výkon / Wattmetry, analyzátory sítí, revizní přístroje (30 V až 500 V, 0,02 A až 200 A) Kalibrace – elektrické veličiny Přímé měření multimetry nebo nepřímé měření bočníkem a multimetrem 1 W až 105 kW CMC 0,060 % MKE-W1 Moc pradu stalego / watomierze, analizatory sieci, mierniki do badan instalacji elektrycznych (30 V do 500 V, 0,02 A do 200 A) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrami lub pomiar posredni bocznikiem i multimetrem od 1 W do 105 kW CMC 0,060 % Stejnosmerny vykon / Wattmetry, analyzatory siti, revizni pristroje (30 V az 500 V, 0,02 A az 200 A) Kalibrace – elektricke veliciny Prime mereni multimetry nebo neprime mereni bocnikem a multimetrem 1 W az 105 kW CMC 0,060 % MKE-W1","search_en":"DC power / Wattmeters, network analyzers, inspection instruments (30 V to 500 V, 0.02 A to 200 A) Calibration – electrical quantities Direct measurement with multimeters or with a shunt and multimeter 1 W to 105 kW CMC 0,060 % MKE-W1","search_zh":"直流功率 / 功率表、电网分析仪、电气安装检测仪（30 V 至 500 V，0,02 A 至 200 A） 校准 – 电学量 用万用表直接测量或用分流器和万用表间接测量 1 W 至 105 kW CMC 0,060 % MKE-W1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e67fc47810fd154868723410","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"11","test_object":"Moc prądu przemiennego / zasilacze, kalibratory mocy (30 V do 500 V, 0,02 A do 200 A, 50 Hz do 60 Hz, cos φ 0,5 do 1)","test_object_en":"AC power / Power supplies, power calibrators (30 V to 500 V, 0.02 A to 200 A, 50 Hz to 60 Hz, cos φ 0.5 to 1)","test_object_zh":"交流功率 / 电源、功率校准器（30 V 至 500 V，0,02 A 至 200 A，50 Hz 至 60 Hz，cos φ 0,5 至 1）","test_object_cs":"Střídavý výkon / Zdroje, kalibrátory výkonu, (30 V až 500 V, 0,02 A až 200 A, 50 Hz až 60 Hz, cos φ 0,5 až 1)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 W do 105 kW","cmc":"0,060 %"}],"parameters_en":[{"name":"","range":"1 W to 105 kW","cmc":"0,060 %"}],"parameters_zh":[{"name":"","range":"1 W 至 105 kW","cmc":"0,060 %"}],"parameters_cs":[{"name":"","range":"1 W až 105 kW","cmc":"0,060 %"}],"technique":"Pomiar bezpośredni licznikiem energii elektrycznej","technique_en":"Direct measurement with an energy meter","technique_zh":"用电能表直接测量","technique_cs":"Přímé měření elektroměrem","techniques":["Pomiar bezpośredni licznikiem energii elektrycznej"],"techniques_en":["Direct measurement with an energy meter"],"techniques_zh":["用电能表直接测量"],"techniques_cs":["Přímé měření elektroměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 W do 105 kW CMC 0,060 %\nPomiar bezpośredni licznikiem energii elektrycznej","reference":"MKE-W1","norm_bases":["MKE-W1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu przemiennego / zasilacze, kalibratory mocy (30 V do 500 V, 0,02 A do 200 A, 50 Hz do 60 Hz, cos φ 0,5 do 1) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni licznikiem energii elektrycznej od 1 W do 105 kW CMC 0,060 % Střídavý výkon / Zdroje, kalibrátory výkonu, (30 V až 500 V, 0,02 A až 200 A, 50 Hz až 60 Hz, cos φ 0,5 až 1) Kalibrace – elektrické veličiny Přímé měření elektroměrem 1 W až 105 kW CMC 0,060 % MKE-W1 Moc pradu przemiennego / zasilacze, kalibratory mocy (30 V do 500 V, 0,02 A do 200 A, 50 Hz do 60 Hz, cos φ 0,5 do 1) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni licznikiem energii elektrycznej od 1 W do 105 kW CMC 0,060 % Stridavy vykon / Zdroje, kalibratory vykonu, (30 V az 500 V, 0,02 A az 200 A, 50 Hz az 60 Hz, cos φ 0,5 az 1) Kalibrace – elektricke veliciny Prime mereni elektromerem 1 W az 105 kW CMC 0,060 % MKE-W1","search_en":"AC power / Power supplies, power calibrators (30 V to 500 V, 0.02 A to 200 A, 50 Hz to 60 Hz, cos φ 0.5 to 1) Calibration – electrical quantities Direct measurement with an energy meter 1 W to 105 kW CMC 0,060 % MKE-W1","search_zh":"交流功率 / 电源、功率校准器（30 V 至 500 V，0,02 A 至 200 A，50 Hz 至 60 Hz，cos φ 0,5 至 1） 校准 – 电学量 用电能表直接测量 1 W 至 105 kW CMC 0,060 % MKE-W1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d63baa933ca625b23817e096","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"11","test_object":"Moc prądu przemiennego / watomierze, analizatory sieci, mierniki do badań instalacji elektrycznych (30 V do 500 V, 0,02 A do 200 A, 50 Hz do 60 Hz, cos φ 0,5 do 1)","test_object_en":"AC power / Wattmeters, network analyzers, inspection instruments (30 V to 500 V, 0.02 A to 200 A, 50 Hz to 60 Hz, cos φ 0.5 to 1)","test_object_zh":"交流功率 / 功率表、电网分析仪、电气安装检测仪（30 V 至 500 V，0,02 A 至 200 A，50 Hz 至 60 Hz，cos φ 0,5 至 1）","test_object_cs":"Střídavý výkon / Wattmetry, analyzátory sítí, revizní přístroje (30 V až 500 V, 0,02 A až 200 A, 50 Hz až 60 Hz, cos φ 0,5 až 1)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 W do 105 kW","cmc":"0,060 %"}],"parameters_en":[{"name":"","range":"1 W to 105 kW","cmc":"0,060 %"}],"parameters_zh":[{"name":"","range":"1 W 至 105 kW","cmc":"0,060 %"}],"parameters_cs":[{"name":"","range":"1 W až 105 kW","cmc":"0,060 %"}],"technique":"Bezpośrednie porównanie z licznikiem energii elektrycznej","technique_en":"Direct comparison with an energy meter","technique_zh":"与电能表直接比较","technique_cs":"Přímé porovnání s elektroměrem","techniques":["Bezpośrednie porównanie z licznikiem energii elektrycznej"],"techniques_en":["Direct comparison with an energy meter"],"techniques_zh":["与电能表直接比较"],"techniques_cs":["Přímé porovnání s elektroměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 W do 105 kW CMC 0,060 %\nBezpośrednie porównanie z licznikiem energii elektrycznej","reference":"MKE-W1","norm_bases":["MKE-W1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu przemiennego / watomierze, analizatory sieci, mierniki do badań instalacji elektrycznych (30 V do 500 V, 0,02 A do 200 A, 50 Hz do 60 Hz, cos φ 0,5 do 1) Wzorcowanie – wielkości elektryczne Bezpośrednie porównanie z licznikiem energii elektrycznej od 1 W do 105 kW CMC 0,060 % Střídavý výkon / Wattmetry, analyzátory sítí, revizní přístroje (30 V až 500 V, 0,02 A až 200 A, 50 Hz až 60 Hz, cos φ 0,5 až 1) Kalibrace – elektrické veličiny Přímé porovnání s elektroměrem 1 W až 105 kW CMC 0,060 % MKE-W1 Moc pradu przemiennego / watomierze, analizatory sieci, mierniki do badan instalacji elektrycznych (30 V do 500 V, 0,02 A do 200 A, 50 Hz do 60 Hz, cos φ 0,5 do 1) Wzorcowanie – wielkosci elektryczne Bezposrednie porownanie z licznikiem energii elektrycznej od 1 W do 105 kW CMC 0,060 % Stridavy vykon / Wattmetry, analyzatory siti, revizni pristroje (30 V az 500 V, 0,02 A az 200 A, 50 Hz az 60 Hz, cos φ 0,5 az 1) Kalibrace – elektricke veliciny Prime porovnani s elektromerem 1 W az 105 kW CMC 0,060 % MKE-W1","search_en":"AC power / Wattmeters, network analyzers, inspection instruments (30 V to 500 V, 0.02 A to 200 A, 50 Hz to 60 Hz, cos φ 0.5 to 1) Calibration – electrical quantities Direct comparison with an energy meter 1 W to 105 kW CMC 0,060 % MKE-W1","search_zh":"交流功率 / 功率表、电网分析仪、电气安装检测仪（30 V 至 500 V，0,02 A 至 200 A，50 Hz 至 60 Hz，cos φ 0,5 至 1） 校准 – 电学量 与电能表直接比较 1 W 至 105 kW CMC 0,060 % MKE-W1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b4301a964e2a976c0841eaa","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"12","test_object":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments","test_object_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪","test_object_cs":"Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0,1 mΩ","cmc":"0,0080 %"},{"name":"","range":"1 mΩ","cmc":"0,0020 %"},{"name":"","range":"0,01 Ω","cmc":"0,0025 %"},{"name":"","range":"0,1 Ω","cmc":"0,0025 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"1,9 Ω","cmc":"0,010 %"},{"name":"","range":"10 Ω","cmc":"0,0026 %"},{"name":"","range":"19 Ω","cmc":"0,0026 %"},{"name":"","range":"100 Ω","cmc":"0,0014 %"},{"name":"","range":"190 Ω","cmc":"0,0014 %"},{"name":"","range":"1 kΩ","cmc":"0,0011 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ","cmc":"0,0011 %"},{"name":"","range":"19 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"},{"name":"","range":"190 kΩ","cmc":"0,0015 %"},{"name":"","range":"1 MΩ","cmc":"0,0026 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0026 %"},{"name":"","range":"10 MΩ","cmc":"0,0050 %"},{"name":"","range":"19 MΩ","cmc":"0,0050 %"},{"name":"","range":"100 MΩ","cmc":"0,0050 %"},{"name":"","range":"1 GΩ","cmc":"0,010 %"}],"parameters_en":[{"name":"","range":"0,1 mΩ","cmc":"0,0080 %"},{"name":"","range":"1 mΩ","cmc":"0,0020 %"},{"name":"","range":"0,01 Ω","cmc":"0,0025 %"},{"name":"","range":"0,1 Ω","cmc":"0,0025 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"1,9 Ω","cmc":"0,010 %"},{"name":"","range":"10 Ω","cmc":"0,0026 %"},{"name":"","range":"19 Ω","cmc":"0,0026 %"},{"name":"","range":"100 Ω","cmc":"0,0014 %"},{"name":"","range":"190 Ω","cmc":"0,0014 %"},{"name":"","range":"1 kΩ","cmc":"0,0011 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ","cmc":"0,0011 %"},{"name":"","range":"19 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"},{"name":"","range":"190 kΩ","cmc":"0,0015 %"},{"name":"","range":"1 MΩ","cmc":"0,0026 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0026 %"},{"name":"","range":"10 MΩ","cmc":"0,0050 %"},{"name":"","range":"19 MΩ","cmc":"0,0050 %"},{"name":"","range":"100 MΩ","cmc":"0,0050 %"},{"name":"","range":"1 GΩ","cmc":"0,010 %"}],"parameters_zh":[{"name":"","range":"0,1 mΩ","cmc":"0,0080 %"},{"name":"","range":"1 mΩ","cmc":"0,0020 %"},{"name":"","range":"0,01 Ω","cmc":"0,0025 %"},{"name":"","range":"0,1 Ω","cmc":"0,0025 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"1,9 Ω","cmc":"0,010 %"},{"name":"","range":"10 Ω","cmc":"0,0026 %"},{"name":"","range":"19 Ω","cmc":"0,0026 %"},{"name":"","range":"100 Ω","cmc":"0,0014 %"},{"name":"","range":"190 Ω","cmc":"0,0014 %"},{"name":"","range":"1 kΩ","cmc":"0,0011 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ","cmc":"0,0011 %"},{"name":"","range":"19 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"},{"name":"","range":"190 kΩ","cmc":"0,0015 %"},{"name":"","range":"1 MΩ","cmc":"0,0026 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0026 %"},{"name":"","range":"10 MΩ","cmc":"0,0050 %"},{"name":"","range":"19 MΩ","cmc":"0,0050 %"},{"name":"","range":"100 MΩ","cmc":"0,0050 %"},{"name":"","range":"1 GΩ","cmc":"0,010 %"}],"parameters_cs":[{"name":"","range":"0,1 mΩ","cmc":"0,0080 %"},{"name":"","range":"1 mΩ","cmc":"0,0020 %"},{"name":"","range":"0,01 Ω","cmc":"0,0025 %"},{"name":"","range":"0,1 Ω","cmc":"0,0025 %"},{"name":"","range":"1 Ω","cmc":"0,0020 %"},{"name":"","range":"1,9 Ω","cmc":"0,010 %"},{"name":"","range":"10 Ω","cmc":"0,0026 %"},{"name":"","range":"19 Ω","cmc":"0,0026 %"},{"name":"","range":"100 Ω","cmc":"0,0014 %"},{"name":"","range":"190 Ω","cmc":"0,0014 %"},{"name":"","range":"1 kΩ","cmc":"0,0011 %"},{"name":"","range":"1,9 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ","cmc":"0,0011 %"},{"name":"","range":"19 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"},{"name":"","range":"190 kΩ","cmc":"0,0015 %"},{"name":"","range":"1 MΩ","cmc":"0,0026 %"},{"name":"","range":"1,9 MΩ","cmc":"0,0026 %"},{"name":"","range":"10 MΩ","cmc":"0,0050 %"},{"name":"","range":"19 MΩ","cmc":"0,0050 %"},{"name":"","range":"100 MΩ","cmc":"0,0050 %"},{"name":"","range":"1 GΩ","cmc":"0,010 %"}],"technique":"Bezpośrednie generowanie rezystorami wzorcowymi","technique_en":"Direct generation by resistance standards","technique_zh":"用电阻标准器直接产生","technique_cs":"Přímé generování odporovými normály","techniques":["Bezpośrednie generowanie rezystorami wzorcowymi"],"techniques_en":["Direct generation by resistance standards"],"techniques_zh":["用电阻标准器直接产生"],"techniques_cs":["Přímé generování odporovými normály"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 mΩ CMC 0,0080 %\n1 mΩ CMC 0,0020 %\n0,01 Ω CMC 0,0025 %\n0,1 Ω CMC 0,0025 %\n1 Ω CMC 0,0020 %\n1,9 Ω CMC 0,010 %\n10 Ω CMC 0,0026 %\n19 Ω CMC 0,0026 %\n100 Ω CMC 0,0014 %\n190 Ω CMC 0,0014 %\n1 kΩ CMC 0,0011 %\n1,9 kΩ CMC 0,0011 %\n10 kΩ CMC 0,0011 %\n19 kΩ CMC 0,0011 %\n100 kΩ CMC 0,0015 %\n190 kΩ CMC 0,0015 %\n1 MΩ CMC 0,0026 %\n1,9 MΩ CMC 0,0026 %\n10 MΩ CMC 0,0050 %\n19 MΩ CMC 0,0050 %\n100 MΩ CMC 0,0050 %\n1 GΩ CMC 0,010 %\nBezpośrednie generowanie rezystorami wzorcowymi","reference":"MKE-RSS1, MKE-SRP.1","norm_bases":["MKE-RSS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie rezystorami wzorcowymi 0,1 mΩ CMC 0,0080 % 1 mΩ CMC 0,0020 % 0,01 Ω CMC 0,0025 % 0,1 Ω CMC 0,0025 % 1 Ω CMC 0,0020 % 1,9 Ω CMC 0,010 % 10 Ω CMC 0,0026 % 19 Ω CMC 0,0026 % 100 Ω CMC 0,0014 % 190 Ω CMC 0,0014 % 1 kΩ CMC 0,0011 % 1,9 kΩ CMC 0,0011 % 10 kΩ CMC 0,0011 % 19 kΩ CMC 0,0011 % 100 kΩ CMC 0,0015 % 190 kΩ CMC 0,0015 % 1 MΩ CMC 0,0026 % 1,9 MΩ CMC 0,0026 % 10 MΩ CMC 0,0050 % 19 MΩ CMC 0,0050 % 100 MΩ CMC 0,0050 % 1 GΩ CMC 0,010 % Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé generování odporovými normály 0,1 mΩ CMC 0,0080 % 1 mΩ CMC 0,0020 % 0,01 Ω CMC 0,0025 % 0,1 Ω CMC 0,0025 % 1 Ω CMC 0,0020 % 1,9 Ω CMC 0,010 % 10 Ω CMC 0,0026 % 19 Ω CMC 0,0026 % 100 Ω CMC 0,0014 % 190 Ω CMC 0,0014 % 1 kΩ CMC 0,0011 % 1,9 kΩ CMC 0,0011 % 10 kΩ CMC 0,0011 % 19 kΩ CMC 0,0011 % 100 kΩ CMC 0,0015 % 190 kΩ CMC 0,0015 % 1 MΩ CMC 0,0026 % 1,9 MΩ CMC 0,0026 % 10 MΩ CMC 0,0050 % 19 MΩ CMC 0,0050 % 100 MΩ CMC 0,0050 % 1 GΩ CMC 0,010 % MKE-RSS1, MKE-SRP.1 Rezystancja przy pradzie stalym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie rezystorami wzorcowymi 0,1 mΩ CMC 0,0080 % 1 mΩ CMC 0,0020 % 0,01 Ω CMC 0,0025 % 0,1 Ω CMC 0,0025 % 1 Ω CMC 0,0020 % 1,9 Ω CMC 0,010 % 10 Ω CMC 0,0026 % 19 Ω CMC 0,0026 % 100 Ω CMC 0,0014 % 190 Ω CMC 0,0014 % 1 kΩ CMC 0,0011 % 1,9 kΩ CMC 0,0011 % 10 kΩ CMC 0,0011 % 19 kΩ CMC 0,0011 % 100 kΩ CMC 0,0015 % 190 kΩ CMC 0,0015 % 1 MΩ CMC 0,0026 % 1,9 MΩ CMC 0,0026 % 10 MΩ CMC 0,0050 % 19 MΩ CMC 0,0050 % 100 MΩ CMC 0,0050 % 1 GΩ CMC 0,010 % Stejnosmerny odpor / Multimetry, rezistory, ohmmetry, odporove dekady, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime generovani odporovymi normaly 0,1 mΩ CMC 0,0080 % 1 mΩ CMC 0,0020 % 0,01 Ω CMC 0,0025 % 0,1 Ω CMC 0,0025 % 1 Ω CMC 0,0020 % 1,9 Ω CMC 0,010 % 10 Ω CMC 0,0026 % 19 Ω CMC 0,0026 % 100 Ω CMC 0,0014 % 190 Ω CMC 0,0014 % 1 kΩ CMC 0,0011 % 1,9 kΩ CMC 0,0011 % 10 kΩ CMC 0,0011 % 19 kΩ CMC 0,0011 % 100 kΩ CMC 0,0015 % 190 kΩ CMC 0,0015 % 1 MΩ CMC 0,0026 % 1,9 MΩ CMC 0,0026 % 10 MΩ CMC 0,0050 % 19 MΩ CMC 0,0050 % 100 MΩ CMC 0,0050 % 1 GΩ CMC 0,010 % MKE-RSS1, MKE-SRP.1","search_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments Calibration – electrical quantities Direct generation by resistance standards 0,1 mΩ CMC 0,0080 % 1 mΩ CMC 0,0020 % 0,01 Ω CMC 0,0025 % 0,1 Ω CMC 0,0025 % 1 Ω CMC 0,0020 % 1,9 Ω CMC 0,010 % 10 Ω CMC 0,0026 % 19 Ω CMC 0,0026 % 100 Ω CMC 0,0014 % 190 Ω CMC 0,0014 % 1 kΩ CMC 0,0011 % 1,9 kΩ CMC 0,0011 % 10 kΩ CMC 0,0011 % 19 kΩ CMC 0,0011 % 100 kΩ CMC 0,0015 % 190 kΩ CMC 0,0015 % 1 MΩ CMC 0,0026 % 1,9 MΩ CMC 0,0026 % 10 MΩ CMC 0,0050 % 19 MΩ CMC 0,0050 % 100 MΩ CMC 0,0050 % 1 GΩ CMC 0,010 % MKE-RSS1, MKE-SRP.1","search_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪 校准 – 电学量 用电阻标准器直接产生 0,1 mΩ CMC 0,0080 % 1 mΩ CMC 0,0020 % 0,01 Ω CMC 0,0025 % 0,1 Ω CMC 0,0025 % 1 Ω CMC 0,0020 % 1,9 Ω CMC 0,010 % 10 Ω CMC 0,0026 % 19 Ω CMC 0,0026 % 100 Ω CMC 0,0014 % 190 Ω CMC 0,0014 % 1 kΩ CMC 0,0011 % 1,9 kΩ CMC 0,0011 % 10 kΩ CMC 0,0011 % 19 kΩ CMC 0,0011 % 100 kΩ CMC 0,0015 % 190 kΩ CMC 0,0015 % 1 MΩ CMC 0,0026 % 1,9 MΩ CMC 0,0026 % 10 MΩ CMC 0,0050 % 19 MΩ CMC 0,0050 % 100 MΩ CMC 0,0050 % 1 GΩ CMC 0,010 % MKE-RSS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"302398a386aa2ff955f76066","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"12","test_object":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments","test_object_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪","test_object_cs":"Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 mΩ do 0,2 mΩ","cmc":"0,040 %"},{"name":"","range":"od 0,2 mΩ do 0,5 mΩ","cmc":"0,0080 %"},{"name":"","range":"od 0,5 mΩ do 0,9 mΩ","cmc":"0,0060 %"},{"name":"","range":"od 0,9 mΩ do 5 Ω","cmc":"0,0040 %"}],"parameters_en":[{"name":"","range":"0,1 mΩ to 0,2 mΩ","cmc":"0,040 %"},{"name":"","range":"0,2 mΩ to 0,5 mΩ","cmc":"0,0080 %"},{"name":"","range":"0,5 mΩ to 0,9 mΩ","cmc":"0,0060 %"},{"name":"","range":"0,9 mΩ to 5 Ω","cmc":"0,0040 %"}],"parameters_zh":[{"name":"","range":"0,1 mΩ 至 0,2 mΩ","cmc":"0,040 %"},{"name":"","range":"0,2 mΩ 至 0,5 mΩ","cmc":"0,0080 %"},{"name":"","range":"0,5 mΩ 至 0,9 mΩ","cmc":"0,0060 %"},{"name":"","range":"0,9 mΩ 至 5 Ω","cmc":"0,0040 %"}],"parameters_cs":[{"name":"","range":"0,1 mΩ až 0,2 mΩ","cmc":"0,040 %"},{"name":"","range":"0,2 mΩ až 0,5 mΩ","cmc":"0,0080 %"},{"name":"","range":"0,5 mΩ až 0,9 mΩ","cmc":"0,0060 %"},{"name":"","range":"0,9 mΩ až 5 Ω","cmc":"0,0040 %"}],"technique":"Pomiar pośredni bocznikiem i multimetrem","technique_en":"Indirect measurement using a shunt and multimeter","technique_zh":"用分流器和万用表间接测量","technique_cs":"Nepřímé měření bočníkem a multimetrem","techniques":["Pomiar pośredni bocznikiem i multimetrem"],"techniques_en":["Indirect measurement using a shunt and multimeter"],"techniques_zh":["用分流器和万用表间接测量"],"techniques_cs":["Nepřímé měření bočníkem a multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,1 mΩ do 0,2 mΩ CMC 0,040 %\nod 0,2 mΩ do 0,5 mΩ CMC 0,0080 %\nod 0,5 mΩ do 0,9 mΩ CMC 0,0060 %\nod 0,9 mΩ do 5 Ω CMC 0,0040 %\nPomiar pośredni bocznikiem i multimetrem","reference":"MKE-RSS1, MKE-SRP.1","norm_bases":["MKE-RSS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar pośredni bocznikiem i multimetrem od 0,1 mΩ do 0,2 mΩ CMC 0,040 % od 0,2 mΩ do 0,5 mΩ CMC 0,0080 % od 0,5 mΩ do 0,9 mΩ CMC 0,0060 % od 0,9 mΩ do 5 Ω CMC 0,0040 % Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Nepřímé měření bočníkem a multimetrem 0,1 mΩ až 0,2 mΩ CMC 0,040 % 0,2 mΩ až 0,5 mΩ CMC 0,0080 % 0,5 mΩ až 0,9 mΩ CMC 0,0060 % 0,9 mΩ až 5 Ω CMC 0,0040 % MKE-RSS1, MKE-SRP.1 Rezystancja przy pradzie stalym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar posredni bocznikiem i multimetrem od 0,1 mΩ do 0,2 mΩ CMC 0,040 % od 0,2 mΩ do 0,5 mΩ CMC 0,0080 % od 0,5 mΩ do 0,9 mΩ CMC 0,0060 % od 0,9 mΩ do 5 Ω CMC 0,0040 % Stejnosmerny odpor / Multimetry, rezistory, ohmmetry, odporove dekady, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Neprime mereni bocnikem a multimetrem 0,1 mΩ az 0,2 mΩ CMC 0,040 % 0,2 mΩ az 0,5 mΩ CMC 0,0080 % 0,5 mΩ az 0,9 mΩ CMC 0,0060 % 0,9 mΩ az 5 Ω CMC 0,0040 % MKE-RSS1, MKE-SRP.1","search_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments Calibration – electrical quantities Indirect measurement using a shunt and multimeter 0,1 mΩ to 0,2 mΩ CMC 0,040 % 0,2 mΩ to 0,5 mΩ CMC 0,0080 % 0,5 mΩ to 0,9 mΩ CMC 0,0060 % 0,9 mΩ to 5 Ω CMC 0,0040 % MKE-RSS1, MKE-SRP.1","search_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪 校准 – 电学量 用分流器和万用表间接测量 0,1 mΩ 至 0,2 mΩ CMC 0,040 % 0,2 mΩ 至 0,5 mΩ CMC 0,0080 % 0,5 mΩ 至 0,9 mΩ CMC 0,0060 % 0,9 mΩ 至 5 Ω CMC 0,0040 % MKE-RSS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c61ea01ccd5f6fe49d0477c1","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"12","test_object":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments","test_object_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪","test_object_cs":"Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 5 Ω do 200 kΩ","cmc":"0,0030 %"},{"name":"","range":"od 200 kΩ do 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"od 2 MΩ do 20 MΩ","cmc":"0,0060 %"},{"name":"","range":"od 20 MΩ do 200 MΩ","cmc":"0,040 %"},{"name":"","range":"od 200 MΩ do 300 MΩ","cmc":"0,070 %"},{"name":"","range":"od 300 MΩ do 500 MΩ","cmc":"0,050 %"},{"name":"","range":"od 500 MΩ do 1 GΩ","cmc":"0,035 %"},{"name":"","range":"od 1 GΩ do 2 GΩ","cmc":"0,020 %"},{"name":"","range":"od 2 GΩ do 10 GΩ","cmc":"0,65 %"},{"name":"","range":"od 10 GΩ do 20 GΩ","cmc":"0,20 %"}],"parameters_en":[{"name":"","range":"5 Ω to 200 kΩ","cmc":"0,0030 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"0,0060 %"},{"name":"","range":"20 MΩ to 200 MΩ","cmc":"0,040 %"},{"name":"","range":"200 MΩ to 300 MΩ","cmc":"0,070 %"},{"name":"","range":"300 MΩ to 500 MΩ","cmc":"0,050 %"},{"name":"","range":"500 MΩ to 1 GΩ","cmc":"0,035 %"},{"name":"","range":"1 GΩ to 2 GΩ","cmc":"0,020 %"},{"name":"","range":"2 GΩ to 10 GΩ","cmc":"0,65 %"},{"name":"","range":"10 GΩ to 20 GΩ","cmc":"0,20 %"}],"parameters_zh":[{"name":"","range":"5 Ω 至 200 kΩ","cmc":"0,0030 %"},{"name":"","range":"200 kΩ 至 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"2 MΩ 至 20 MΩ","cmc":"0,0060 %"},{"name":"","range":"20 MΩ 至 200 MΩ","cmc":"0,040 %"},{"name":"","range":"200 MΩ 至 300 MΩ","cmc":"0,070 %"},{"name":"","range":"300 MΩ 至 500 MΩ","cmc":"0,050 %"},{"name":"","range":"500 MΩ 至 1 GΩ","cmc":"0,035 %"},{"name":"","range":"1 GΩ 至 2 GΩ","cmc":"0,020 %"},{"name":"","range":"2 GΩ 至 10 GΩ","cmc":"0,65 %"},{"name":"","range":"10 GΩ 至 20 GΩ","cmc":"0,20 %"}],"parameters_cs":[{"name":"","range":"5 Ω až 200 kΩ","cmc":"0,0030 %"},{"name":"","range":"200 kΩ až 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"2 MΩ až 20 MΩ","cmc":"0,0060 %"},{"name":"","range":"20 MΩ až 200 MΩ","cmc":"0,040 %"},{"name":"","range":"200 MΩ až 300 MΩ","cmc":"0,070 %"},{"name":"","range":"300 MΩ až 500 MΩ","cmc":"0,050 %"},{"name":"","range":"500 MΩ až 1 GΩ","cmc":"0,035 %"},{"name":"","range":"1 GΩ až 2 GΩ","cmc":"0,020 %"},{"name":"","range":"2 GΩ až 10 GΩ","cmc":"0,65 %"},{"name":"","range":"10 GΩ až 20 GΩ","cmc":"0,20 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 5 Ω do 200 kΩ CMC 0,0030 %\nod 200 kΩ do 2 MΩ CMC 0,0040 %\nod 2 MΩ do 20 MΩ CMC 0,0060 %\nod 20 MΩ do 200 MΩ CMC 0,040 %\nod 200 MΩ do 300 MΩ CMC 0,070 %\nod 300 MΩ do 500 MΩ CMC 0,050 %\nod 500 MΩ do 1 GΩ CMC 0,035 %\nod 1 GΩ do 2 GΩ CMC 0,020 %\nod 2 GΩ do 10 GΩ CMC 0,65 %\nod 10 GΩ do 20 GΩ CMC 0,20 %\nPomiar bezpośredni multimetrem","reference":"MKE-RSS1, MKE-SRP.1","norm_bases":["MKE-RSS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 5 Ω do 200 kΩ CMC 0,0030 % od 200 kΩ do 2 MΩ CMC 0,0040 % od 2 MΩ do 20 MΩ CMC 0,0060 % od 20 MΩ do 200 MΩ CMC 0,040 % od 200 MΩ do 300 MΩ CMC 0,070 % od 300 MΩ do 500 MΩ CMC 0,050 % od 500 MΩ do 1 GΩ CMC 0,035 % od 1 GΩ do 2 GΩ CMC 0,020 % od 2 GΩ do 10 GΩ CMC 0,65 % od 10 GΩ do 20 GΩ CMC 0,20 % Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Přímé měření multimetrem 5 Ω až 200 kΩ CMC 0,0030 % 200 kΩ až 2 MΩ CMC 0,0040 % 2 MΩ až 20 MΩ CMC 0,0060 % 20 MΩ až 200 MΩ CMC 0,040 % 200 MΩ až 300 MΩ CMC 0,070 % 300 MΩ až 500 MΩ CMC 0,050 % 500 MΩ až 1 GΩ CMC 0,035 % 1 GΩ až 2 GΩ CMC 0,020 % 2 GΩ až 10 GΩ CMC 0,65 % 10 GΩ až 20 GΩ CMC 0,20 % MKE-RSS1, MKE-SRP.1 Rezystancja przy pradzie stalym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 5 Ω do 200 kΩ CMC 0,0030 % od 200 kΩ do 2 MΩ CMC 0,0040 % od 2 MΩ do 20 MΩ CMC 0,0060 % od 20 MΩ do 200 MΩ CMC 0,040 % od 200 MΩ do 300 MΩ CMC 0,070 % od 300 MΩ do 500 MΩ CMC 0,050 % od 500 MΩ do 1 GΩ CMC 0,035 % od 1 GΩ do 2 GΩ CMC 0,020 % od 2 GΩ do 10 GΩ CMC 0,65 % od 10 GΩ do 20 GΩ CMC 0,20 % Stejnosmerny odpor / Multimetry, rezistory, ohmmetry, odporove dekady, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Prime mereni multimetrem 5 Ω az 200 kΩ CMC 0,0030 % 200 kΩ az 2 MΩ CMC 0,0040 % 2 MΩ az 20 MΩ CMC 0,0060 % 20 MΩ az 200 MΩ CMC 0,040 % 200 MΩ az 300 MΩ CMC 0,070 % 300 MΩ az 500 MΩ CMC 0,050 % 500 MΩ az 1 GΩ CMC 0,035 % 1 GΩ az 2 GΩ CMC 0,020 % 2 GΩ az 10 GΩ CMC 0,65 % 10 GΩ az 20 GΩ CMC 0,20 % MKE-RSS1, MKE-SRP.1","search_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments Calibration – electrical quantities Direct measurement using a multimeter 5 Ω to 200 kΩ CMC 0,0030 % 200 kΩ to 2 MΩ CMC 0,0040 % 2 MΩ to 20 MΩ CMC 0,0060 % 20 MΩ to 200 MΩ CMC 0,040 % 200 MΩ to 300 MΩ CMC 0,070 % 300 MΩ to 500 MΩ CMC 0,050 % 500 MΩ to 1 GΩ CMC 0,035 % 1 GΩ to 2 GΩ CMC 0,020 % 2 GΩ to 10 GΩ CMC 0,65 % 10 GΩ to 20 GΩ CMC 0,20 % MKE-RSS1, MKE-SRP.1","search_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪 校准 – 电学量 用万用表直接测量 5 Ω 至 200 kΩ CMC 0,0030 % 200 kΩ 至 2 MΩ CMC 0,0040 % 2 MΩ 至 20 MΩ CMC 0,0060 % 20 MΩ 至 200 MΩ CMC 0,040 % 200 MΩ 至 300 MΩ CMC 0,070 % 300 MΩ 至 500 MΩ CMC 0,050 % 500 MΩ 至 1 GΩ CMC 0,035 % 1 GΩ 至 2 GΩ CMC 0,020 % 2 GΩ 至 10 GΩ CMC 0,65 % 10 GΩ 至 20 GΩ CMC 0,20 % MKE-RSS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc47f79b7e7d7ef9cef3cb6b","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"12","test_object":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych","test_object_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments","test_object_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪","test_object_cs":"Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"do 10000 V","range":"od 20 GΩ do 250 GΩ","cmc":"0,50 %"},{"name":"do 10000 V","range":"od 250 GΩ do 1 TΩ","cmc":"0,70 %"}],"parameters_en":[{"name":"up to 10000 V","range":"20 GΩ to 250 GΩ","cmc":"0,50 %"},{"name":"up to 10000 V","range":"250 GΩ to 1 TΩ","cmc":"0,70 %"}],"parameters_zh":[{"name":"最高 10000 V","range":"20 GΩ 至 250 GΩ","cmc":"0,50 %"},{"name":"最高 10000 V","range":"250 GΩ 至 1 TΩ","cmc":"0,70 %"}],"parameters_cs":[{"name":"do 10000 V","range":"20 GΩ až 250 GΩ","cmc":"0,50 %"},{"name":"do 10000 V","range":"250 GΩ až 1 TΩ","cmc":"0,70 %"}],"technique":"Pomiar pośredni pikoamperomierzem i woltomierzem wysokiego napięcia","technique_en":"Indirect measurement using a picoammeter and HV voltmeter","technique_zh":"用皮安表和高压电压表间接测量","technique_cs":"Nepřímé měření pikoampérmetrem a vn voltmetrem","techniques":["Pomiar pośredni pikoamperomierzem i woltomierzem wysokiego napięcia"],"techniques_en":["Indirect measurement using a picoammeter and HV voltmeter"],"techniques_zh":["用皮安表和高压电压表间接测量"],"techniques_cs":["Nepřímé měření pikoampérmetrem a vn voltmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\ndo 10000 V od 20 GΩ do 250 GΩ CMC 0,50 %\ndo 10000 V od 250 GΩ do 1 TΩ CMC 0,70 %\nPomiar pośredni pikoamperomierzem i woltomierzem wysokiego napięcia","reference":"MKE-RSS, MKE-SRP.1","norm_bases":["MKE-RSS","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar pośredni pikoamperomierzem i woltomierzem wysokiego napięcia do 10000 V od 20 GΩ do 250 GΩ CMC 0,50 % do 10000 V od 250 GΩ do 1 TΩ CMC 0,70 % Stejnosměrný odpor / Multimetry, rezistory, ohmmetry, odporové dekády, kalibrátory, revizní přístroje Kalibrace – elektrické veličiny Nepřímé měření pikoampérmetrem a vn voltmetrem do 10000 V 20 GΩ až 250 GΩ CMC 0,50 % do 10000 V 250 GΩ až 1 TΩ CMC 0,70 % MKE-RSS, MKE-SRP.1 Rezystancja przy pradzie stalym / multimetry, rezystory, omomierze, dekady rezystancyjne, kalibratory, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar posredni pikoamperomierzem i woltomierzem wysokiego napiecia do 10000 V od 20 GΩ do 250 GΩ CMC 0,50 % do 10000 V od 250 GΩ do 1 TΩ CMC 0,70 % Stejnosmerny odpor / Multimetry, rezistory, ohmmetry, odporove dekady, kalibratory, revizni pristroje Kalibrace – elektricke veliciny Neprime mereni pikoampermetrem a vn voltmetrem do 10000 V 20 GΩ az 250 GΩ CMC 0,50 % do 10000 V 250 GΩ az 1 TΩ CMC 0,70 % MKE-RSS, MKE-SRP.1","search_en":"DC resistance / Multimeters, resistors, ohmmeters, resistance boxes, calibrators, inspection instruments Calibration – electrical quantities Indirect measurement using a picoammeter and HV voltmeter up to 10000 V 20 GΩ to 250 GΩ CMC 0,50 % up to 10000 V 250 GΩ to 1 TΩ CMC 0,70 % MKE-RSS, MKE-SRP.1","search_zh":"直流电阻 / 万用表、电阻器、欧姆表、电阻箱、校准器、电气安装检测仪 校准 – 电学量 用皮安表和高压电压表间接测量 最高 10000 V 20 GΩ 至 250 GΩ CMC 0,50 % 最高 10000 V 250 GΩ 至 1 TΩ CMC 0,70 % MKE-RSS, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bd90f26ba0c573e61d3ab78","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"13","test_object":"Moduł impedancji / wzorce rezystancji, dekady rezystancyjne, mierniki rezystancji, mierniki cęgowe, mierniki do badań instalacji","test_object_en":"Impedance module / Resistance standards, resistance boxes, resistance meters, clamp meters, inspection meters","test_object_zh":"阻抗模 / 电阻标准器、电阻箱、电阻测量仪、钳形表、检测用仪表","test_object_cs":"Modul impedance / Etalony odporu, odporové dekády, měřidla odporu, klešťová měřidla, měřidla pro revize","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 60 Hz","range":"od 0,1 mΩ do 0,1 Ω","cmc":"0,2 %"},{"name":"50 Hz do 1 kHz","range":"od 0,1 Ω do 10 Ω","cmc":"0,2 %"}],"parameters_en":[{"name":"50 Hz to 60 Hz","range":"0,1 mΩ to 0,1 Ω","cmc":"0,2 %"},{"name":"50 Hz to 1 kHz","range":"0,1 Ω to 10 Ω","cmc":"0,2 %"}],"parameters_zh":[{"name":"50 Hz 至 60 Hz","range":"0,1 mΩ 至 0,1 Ω","cmc":"0,2 %"},{"name":"50 Hz 至 1 kHz","range":"0,1 Ω 至 10 Ω","cmc":"0,2 %"}],"parameters_cs":[{"name":"50 Hz až 60 Hz","range":"0,1 mΩ až 0,1 Ω","cmc":"0,2 %"},{"name":"50 Hz až 1 kHz","range":"0,1 Ω až 10 Ω","cmc":"0,2 %"}],"technique":"Metoda VA (techniczna)","technique_en":"VA method","technique_zh":"伏安法","technique_cs":"VA metoda","techniques":["Metoda VA (techniczna)"],"techniques_en":["VA method"],"techniques_zh":["伏安法"],"techniques_cs":["VA metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz do 60 Hz od 0,1 mΩ do 0,1 Ω CMC 0,2 %\n50 Hz do 1 kHz od 0,1 Ω do 10 Ω CMC 0,2 %\nMetoda VA (techniczna)","reference":"MKE-Z2, MKE-SRP.1","norm_bases":["MKE-Z2","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł impedancji / wzorce rezystancji, dekady rezystancyjne, mierniki rezystancji, mierniki cęgowe, mierniki do badań instalacji Wzorcowanie – wielkości elektryczne Metoda VA (techniczna) 50 Hz do 60 Hz od 0,1 mΩ do 0,1 Ω CMC 0,2 % 50 Hz do 1 kHz od 0,1 Ω do 10 Ω CMC 0,2 % Modul impedance / Etalony odporu, odporové dekády, měřidla odporu, klešťová měřidla, měřidla pro revize Kalibrace – elektrické veličiny VA metoda 50 Hz až 60 Hz 0,1 mΩ až 0,1 Ω CMC 0,2 % 50 Hz až 1 kHz 0,1 Ω až 10 Ω CMC 0,2 % MKE-Z2, MKE-SRP.1 Modul impedancji / wzorce rezystancji, dekady rezystancyjne, mierniki rezystancji, mierniki cegowe, mierniki do badan instalacji Wzorcowanie – wielkosci elektryczne Metoda VA (techniczna) 50 Hz do 60 Hz od 0,1 mΩ do 0,1 Ω CMC 0,2 % 50 Hz do 1 kHz od 0,1 Ω do 10 Ω CMC 0,2 % Modul impedance / Etalony odporu, odporove dekady, meridla odporu, klestova meridla, meridla pro revize Kalibrace – elektricke veliciny VA metoda 50 Hz az 60 Hz 0,1 mΩ az 0,1 Ω CMC 0,2 % 50 Hz az 1 kHz 0,1 Ω az 10 Ω CMC 0,2 % MKE-Z2, MKE-SRP.1","search_en":"Impedance module / Resistance standards, resistance boxes, resistance meters, clamp meters, inspection meters Calibration – electrical quantities VA method 50 Hz to 60 Hz 0,1 mΩ to 0,1 Ω CMC 0,2 % 50 Hz to 1 kHz 0,1 Ω to 10 Ω CMC 0,2 % MKE-Z2, MKE-SRP.1","search_zh":"阻抗模 / 电阻标准器、电阻箱、电阻测量仪、钳形表、检测用仪表 校准 – 电学量 伏安法 50 Hz 至 60 Hz 0,1 mΩ 至 0,1 Ω CMC 0,2 % 50 Hz 至 1 kHz 0,1 Ω 至 10 Ω CMC 0,2 % MKE-Z2, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"71f86b2c92707f2ce8b89300","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"14","test_object":"Moduł impedancji, rezystancja przy prądzie przemiennym / wzorce, mierniki rezystancji, mostki RLC","test_object_en":"Impedance module, AC resistance / standards, resistance meters, RLC bridges","test_object_zh":"阻抗模、交流电阻 / 标准器、电阻测量仪、RLC 电桥","test_object_cs":"Modul impedance, střídavý odpor / etalony, měřidla odporu, RLC mosty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 50 Hz","range":"100 mΩ","cmc":"0,30 %"},{"name":"50 Hz do 10 kHz","range":"100 mΩ","cmc":"0,14 %"},{"name":"20 Hz do 100 Hz","range":"1 Ω","cmc":"0,035 %"},{"name":"100 Hz","range":"1 Ω","cmc":"0,015 %"},{"name":"100 Hz do 1 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,015 %"},{"name":"1 kHz do 10 kHz","range":"1 Ω","cmc":"0,025 %"},{"name":"10 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"10 kHz do 100 kHz","range":"1 Ω","cmc":"0,090 %"},{"name":"20 Hz do 100 Hz","range":"10 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"10 Ω","cmc":"0,011 %"},{"name":"100 Hz do 1 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"1 kHz do 10 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"10 kHz do 100 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,040 %"},{"name":"100 kHz do 1 MHz","range":"10 Ω","cmc":"0,15 %"},{"name":"20 Hz do 100 Hz","range":"100 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"100 Ω","cmc":"0,011 %"},{"name":"100 Hz do 1 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"1 kHz do 10 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"10 kHz do 100 kHz","range":"100 Ω","cmc":"0,040 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,035 %"},{"name":"100 kHz do 1 MHz","range":"100 Ω","cmc":"0,15 %"},{"name":"20 Hz do 100 Hz","range":"1 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 Hz do 1 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"1 kHz do 10 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"10 kHz do 100 kHz","range":"1 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,035 %"},{"name":"100 kHz do 1 MHz","range":"1 kΩ","cmc":"0,15 %"},{"name":"20 Hz do 100 Hz","range":"10 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 Hz do 1 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"1 kHz do 10 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"10 kHz do 100 kHz","range":"10 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,035 %"},{"name":"100 kHz do 1 MHz","range":"10 kΩ","cmc":"0,15 %"},{"name":"20 Hz do 100 Hz","range":"100 kΩ","cmc":"0,020 %"},{"name":"100 Hz","range":"100 kΩ","cmc":"0,011 %"},{"name":"100 Hz do 1 kHz","range":"100 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,011 %"},{"name":"1 kHz do 10 kHz","range":"100 kΩ","cmc":"0,020 %"},{"name":"10 kHz","range":"100 kΩ","cmc":"0,015 %"},{"name":"10 kHz do 100 kHz","range":"100 kΩ","cmc":"0,20 %"},{"name":"20 Hz do 100 Hz","range":"1 MΩ","cmc":"0,035 %"},{"name":"100 Hz","range":"1 MΩ","cmc":"0,018 %"},{"name":"100 Hz do 1 kHz","range":"1 MΩ","cmc":"0,025 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,018 %"},{"name":"1 kHz do 10 kHz","range":"1 MΩ","cmc":"0,060 %"},{"name":"10 kHz","range":"1 MΩ","cmc":"0,050 %"},{"name":"10 kHz do 100 kHz","range":"1 MΩ","cmc":"0,50 %"},{"name":"20 Hz do 100 Hz","range":"10 MΩ","cmc":"0,10 %"},{"name":"100 Hz","range":"10 MΩ","cmc":"0,050 %"},{"name":"100 Hz do 1 kHz","range":"10 MΩ","cmc":"0,055 %"},{"name":"1 kHz","range":"10 MΩ","cmc":"0,050 %"},{"name":"1 kHz do 10 kHz","range":"10 MΩ","cmc":"0,18 %"},{"name":"20 Hz do 100 Hz","range":"100 MΩ","cmc":"0,40 %"},{"name":"100 Hz do 1 kHz","range":"100 MΩ","cmc":"0,50 %"}],"parameters_en":[{"name":"20 Hz to 50 Hz","range":"100 mΩ","cmc":"0,30 %"},{"name":"50 Hz to 10 kHz","range":"100 mΩ","cmc":"0,14 %"},{"name":"20 Hz to 100 Hz","range":"1 Ω","cmc":"0,035 %"},{"name":"100 Hz","range":"1 Ω","cmc":"0,015 %"},{"name":"100 Hz to 1 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,015 %"},{"name":"1 kHz to 10 kHz","range":"1 Ω","cmc":"0,025 %"},{"name":"10 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"10 kHz to 100 kHz","range":"1 Ω","cmc":"0,090 %"},{"name":"20 Hz to 100 Hz","range":"10 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"10 Ω","cmc":"0,011 %"},{"name":"100 Hz to 1 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"1 kHz to 10 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"10 kHz to 100 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,040 %"},{"name":"100 kHz to 1 MHz","range":"10 Ω","cmc":"0,15 %"},{"name":"20 Hz to 100 Hz","range":"100 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"100 Ω","cmc":"0,011 %"},{"name":"100 Hz to 1 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"1 kHz to 10 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"10 kHz to 100 kHz","range":"100 Ω","cmc":"0,040 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,035 %"},{"name":"100 kHz to 1 MHz","range":"100 Ω","cmc":"0,15 %"},{"name":"20 Hz to 100 Hz","range":"1 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 Hz to 1 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"1 kHz to 10 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"10 kHz to 100 kHz","range":"1 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,035 %"},{"name":"100 kHz to 1 MHz","range":"1 kΩ","cmc":"0,15 %"},{"name":"20 Hz to 100 Hz","range":"10 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 Hz to 1 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"1 kHz to 10 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"10 kHz to 100 kHz","range":"10 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,035 %"},{"name":"100 kHz to 1 MHz","range":"10 kΩ","cmc":"0,15 %"},{"name":"20 Hz to 100 Hz","range":"100 kΩ","cmc":"0,020 %"},{"name":"100 Hz","range":"100 kΩ","cmc":"0,011 %"},{"name":"100 Hz to 1 kHz","range":"100 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,011 %"},{"name":"1 kHz to 10 kHz","range":"100 kΩ","cmc":"0,020 %"},{"name":"10 kHz","range":"100 kΩ","cmc":"0,015 %"},{"name":"10 kHz to 100 kHz","range":"100 kΩ","cmc":"0,20 %"},{"name":"20 Hz to 100 Hz","range":"1 MΩ","cmc":"0,035 %"},{"name":"100 Hz","range":"1 MΩ","cmc":"0,018 %"},{"name":"100 Hz to 1 kHz","range":"1 MΩ","cmc":"0,025 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,018 %"},{"name":"1 kHz to 10 kHz","range":"1 MΩ","cmc":"0,060 %"},{"name":"10 kHz","range":"1 MΩ","cmc":"0,050 %"},{"name":"10 kHz to 100 kHz","range":"1 MΩ","cmc":"0,50 %"},{"name":"20 Hz to 100 Hz","range":"10 MΩ","cmc":"0,10 %"},{"name":"100 Hz","range":"10 MΩ","cmc":"0,050 %"},{"name":"100 Hz to 1 kHz","range":"10 MΩ","cmc":"0,055 %"},{"name":"1 kHz","range":"10 MΩ","cmc":"0,050 %"},{"name":"1 kHz to 10 kHz","range":"10 MΩ","cmc":"0,18 %"},{"name":"20 Hz to 100 Hz","range":"100 MΩ","cmc":"0,40 %"},{"name":"100 Hz to 1 kHz","range":"100 MΩ","cmc":"0,50 %"}],"parameters_zh":[{"name":"20 Hz 至 50 Hz","range":"100 mΩ","cmc":"0,30 %"},{"name":"50 Hz 至 10 kHz","range":"100 mΩ","cmc":"0,14 %"},{"name":"20 Hz 至 100 Hz","range":"1 Ω","cmc":"0,035 %"},{"name":"100 Hz","range":"1 Ω","cmc":"0,015 %"},{"name":"100 Hz 至 1 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,015 %"},{"name":"1 kHz 至 10 kHz","range":"1 Ω","cmc":"0,025 %"},{"name":"10 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"10 kHz 至 100 kHz","range":"1 Ω","cmc":"0,090 %"},{"name":"20 Hz 至 100 Hz","range":"10 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"10 Ω","cmc":"0,011 %"},{"name":"100 Hz 至 1 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"1 kHz 至 10 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"10 kHz 至 100 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,040 %"},{"name":"100 kHz 至 1 MHz","range":"10 Ω","cmc":"0,15 %"},{"name":"20 Hz 至 100 Hz","range":"100 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"100 Ω","cmc":"0,011 %"},{"name":"100 Hz 至 1 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"1 kHz 至 10 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"10 kHz 至 100 kHz","range":"100 Ω","cmc":"0,040 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,035 %"},{"name":"100 kHz 至 1 MHz","range":"100 Ω","cmc":"0,15 %"},{"name":"20 Hz 至 100 Hz","range":"1 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 Hz 至 1 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"1 kHz 至 10 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"10 kHz 至 100 kHz","range":"1 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,035 %"},{"name":"100 kHz 至 1 MHz","range":"1 kΩ","cmc":"0,15 %"},{"name":"20 Hz 至 100 Hz","range":"10 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 Hz 至 1 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"1 kHz 至 10 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"10 kHz 至 100 kHz","range":"10 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,035 %"},{"name":"100 kHz 至 1 MHz","range":"10 kΩ","cmc":"0,15 %"},{"name":"20 Hz 至 100 Hz","range":"100 kΩ","cmc":"0,020 %"},{"name":"100 Hz","range":"100 kΩ","cmc":"0,011 %"},{"name":"100 Hz 至 1 kHz","range":"100 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,011 %"},{"name":"1 kHz 至 10 kHz","range":"100 kΩ","cmc":"0,020 %"},{"name":"10 kHz","range":"100 kΩ","cmc":"0,015 %"},{"name":"10 kHz 至 100 kHz","range":"100 kΩ","cmc":"0,20 %"},{"name":"20 Hz 至 100 Hz","range":"1 MΩ","cmc":"0,035 %"},{"name":"100 Hz","range":"1 MΩ","cmc":"0,018 %"},{"name":"100 Hz 至 1 kHz","range":"1 MΩ","cmc":"0,025 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,018 %"},{"name":"1 kHz 至 10 kHz","range":"1 MΩ","cmc":"0,060 %"},{"name":"10 kHz","range":"1 MΩ","cmc":"0,050 %"},{"name":"10 kHz 至 100 kHz","range":"1 MΩ","cmc":"0,50 %"},{"name":"20 Hz 至 100 Hz","range":"10 MΩ","cmc":"0,10 %"},{"name":"100 Hz","range":"10 MΩ","cmc":"0,050 %"},{"name":"100 Hz 至 1 kHz","range":"10 MΩ","cmc":"0,055 %"},{"name":"1 kHz","range":"10 MΩ","cmc":"0,050 %"},{"name":"1 kHz 至 10 kHz","range":"10 MΩ","cmc":"0,18 %"},{"name":"20 Hz 至 100 Hz","range":"100 MΩ","cmc":"0,40 %"},{"name":"100 Hz 至 1 kHz","range":"100 MΩ","cmc":"0,50 %"}],"parameters_cs":[{"name":"20 Hz až 50 Hz","range":"100 mΩ","cmc":"0,30 %"},{"name":"50 Hz až 10 kHz","range":"100 mΩ","cmc":"0,14 %"},{"name":"20 Hz až 100 Hz","range":"1 Ω","cmc":"0,035 %"},{"name":"100 Hz","range":"1 Ω","cmc":"0,015 %"},{"name":"100 Hz až 1 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"1 kHz","range":"1 Ω","cmc":"0,015 %"},{"name":"1 kHz až 10 kHz","range":"1 Ω","cmc":"0,025 %"},{"name":"10 kHz","range":"1 Ω","cmc":"0,020 %"},{"name":"10 kHz až 100 kHz","range":"1 Ω","cmc":"0,090 %"},{"name":"20 Hz až 100 Hz","range":"10 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"10 Ω","cmc":"0,011 %"},{"name":"100 Hz až 1 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"1 kHz až 10 kHz","range":"10 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"10 Ω","cmc":"0,011 %"},{"name":"10 kHz až 100 kHz","range":"10 Ω","cmc":"0,045 %"},{"name":"100 kHz","range":"10 Ω","cmc":"0,040 %"},{"name":"100 kHz až 1 MHz","range":"10 Ω","cmc":"0,15 %"},{"name":"20 Hz až 100 Hz","range":"100 Ω","cmc":"0,016 %"},{"name":"100 Hz","range":"100 Ω","cmc":"0,011 %"},{"name":"100 Hz až 1 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"1 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"1 kHz až 10 kHz","range":"100 Ω","cmc":"0,016 %"},{"name":"10 kHz","range":"100 Ω","cmc":"0,011 %"},{"name":"10 kHz až 100 kHz","range":"100 Ω","cmc":"0,040 %"},{"name":"100 kHz","range":"100 Ω","cmc":"0,035 %"},{"name":"100 kHz až 1 MHz","range":"100 Ω","cmc":"0,15 %"},{"name":"20 Hz až 100 Hz","range":"1 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"1 kΩ","cmc":"0,011 %"},{"name":"100 Hz až 1 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"1 kHz až 10 kHz","range":"1 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"1 kΩ","cmc":"0,011 %"},{"name":"10 kHz až 100 kHz","range":"1 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"1 kΩ","cmc":"0,035 %"},{"name":"100 kHz až 1 MHz","range":"1 kΩ","cmc":"0,15 %"},{"name":"20 Hz až 100 Hz","range":"10 kΩ","cmc":"0,016 %"},{"name":"100 Hz","range":"10 kΩ","cmc":"0,011 %"},{"name":"100 Hz až 1 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"1 kHz až 10 kHz","range":"10 kΩ","cmc":"0,016 %"},{"name":"10 kHz","range":"10 kΩ","cmc":"0,011 %"},{"name":"10 kHz až 100 kHz","range":"10 kΩ","cmc":"0,040 %"},{"name":"100 kHz","range":"10 kΩ","cmc":"0,035 %"},{"name":"100 kHz až 1 MHz","range":"10 kΩ","cmc":"0,15 %"},{"name":"20 Hz až 100 Hz","range":"100 kΩ","cmc":"0,020 %"},{"name":"100 Hz","range":"100 kΩ","cmc":"0,011 %"},{"name":"100 Hz až 1 kHz","range":"100 kΩ","cmc":"0,016 %"},{"name":"1 kHz","range":"100 kΩ","cmc":"0,011 %"},{"name":"1 kHz až 10 kHz","range":"100 kΩ","cmc":"0,020 %"},{"name":"10 kHz","range":"100 kΩ","cmc":"0,015 %"},{"name":"10 kHz až 100 kHz","range":"100 kΩ","cmc":"0,20 %"},{"name":"20 Hz až 100 Hz","range":"1 MΩ","cmc":"0,035 %"},{"name":"100 Hz","range":"1 MΩ","cmc":"0,018 %"},{"name":"100 Hz až 1 kHz","range":"1 MΩ","cmc":"0,025 %"},{"name":"1 kHz","range":"1 MΩ","cmc":"0,018 %"},{"name":"1 kHz až 10 kHz","range":"1 MΩ","cmc":"0,060 %"},{"name":"10 kHz","range":"1 MΩ","cmc":"0,050 %"},{"name":"10 kHz až 100 kHz","range":"1 MΩ","cmc":"0,50 %"},{"name":"20 Hz až 100 Hz","range":"10 MΩ","cmc":"0,10 %"},{"name":"100 Hz","range":"10 MΩ","cmc":"0,050 %"},{"name":"100 Hz až 1 kHz","range":"10 MΩ","cmc":"0,055 %"},{"name":"1 kHz","range":"10 MΩ","cmc":"0,050 %"},{"name":"1 kHz až 10 kHz","range":"10 MΩ","cmc":"0,18 %"},{"name":"20 Hz až 100 Hz","range":"100 MΩ","cmc":"0,40 %"},{"name":"100 Hz až 1 kHz","range":"100 MΩ","cmc":"0,50 %"}],"technique":"Porównanie metodą substytucji lub pomiar bezpośredni wzorca impedancji","technique_en":"Comparison by substitution or direct measurement of impedance standard","technique_zh":"替代法比较或直接测量阻抗标准器","technique_cs":"Porovnání substitucí nebo přímé měření etalonu impedance","techniques":["Porównanie metodą substytucji lub pomiar bezpośredni wzorca impedancji"],"techniques_en":["Comparison by substitution or direct measurement of impedance standard"],"techniques_zh":["替代法比较或直接测量阻抗标准器"],"techniques_cs":["Porovnání substitucí nebo přímé měření etalonu impedance"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 50 Hz 100 mΩ CMC 0,30 %\n50 Hz do 10 kHz 100 mΩ CMC 0,14 %\n20 Hz do 100 Hz 1 Ω CMC 0,035 %\n100 Hz 1 Ω CMC 0,015 %\n100 Hz do 1 kHz 1 Ω CMC 0,020 %\n1 kHz 1 Ω CMC 0,015 %\n1 kHz do 10 kHz 1 Ω CMC 0,025 %\n10 kHz 1 Ω CMC 0,020 %\n10 kHz do 100 kHz 1 Ω CMC 0,090 %\n20 Hz do 100 Hz 10 Ω CMC 0,016 %\n100 Hz 10 Ω CMC 0,011 %\n100 Hz do 1 kHz 10 Ω CMC 0,016 %\n1 kHz 10 Ω CMC 0,011 %\n1 kHz do 10 kHz 10 Ω CMC 0,016 %\n10 kHz 10 Ω CMC 0,011 %\n10 kHz do 100 kHz 10 Ω CMC 0,045 %\n100 kHz 10 Ω CMC 0,040 %\n100 kHz do 1 MHz 10 Ω CMC 0,15 %\n20 Hz do 100 Hz 100 Ω CMC 0,016 %\n100 Hz 100 Ω CMC 0,011 %\n100 Hz do 1 kHz 100 Ω CMC 0,016 %\n1 kHz 100 Ω CMC 0,011 %\n1 kHz do 10 kHz 100 Ω CMC 0,016 %\n10 kHz 100 Ω CMC 0,011 %\n10 kHz do 100 kHz 100 Ω CMC 0,040 %\n100 kHz 100 Ω CMC 0,035 %\n100 kHz do 1 MHz 100 Ω CMC 0,15 %\n20 Hz do 100 Hz 1 kΩ CMC 0,016 %\n100 Hz 1 kΩ CMC 0,011 %\n100 Hz do 1 kHz 1 kΩ CMC 0,016 %\n1 kHz 1 kΩ CMC 0,011 %\n1 kHz do 10 kHz 1 kΩ CMC 0,016 %\n10 kHz 1 kΩ CMC 0,011 %\n10 kHz do 100 kHz 1 kΩ CMC 0,040 %\n100 kHz 1 kΩ CMC 0,035 %\n100 kHz do 1 MHz 1 kΩ CMC 0,15 %\n20 Hz do 100 Hz 10 kΩ CMC 0,016 %\n100 Hz 10 kΩ CMC 0,011 %\n100 Hz do 1 kHz 10 kΩ CMC 0,016 %\n1 kHz 10 kΩ CMC 0,011 %\n1 kHz do 10 kHz 10 kΩ CMC 0,016 %\n10 kHz 10 kΩ CMC 0,011 %\n10 kHz do 100 kHz 10 kΩ CMC 0,040 %\n100 kHz 10 kΩ CMC 0,035 %\n100 kHz do 1 MHz 10 kΩ CMC 0,15 %\n20 Hz do 100 Hz 100 kΩ CMC 0,020 %\n100 Hz 100 kΩ CMC 0,011 %\n100 Hz do 1 kHz 100 kΩ CMC 0,016 %\n1 kHz 100 kΩ CMC 0,011 %\n1 kHz do 10 kHz 100 kΩ CMC 0,020 %\n10 kHz 100 kΩ CMC 0,015 %\n10 kHz do 100 kHz 100 kΩ CMC 0,20 %\n20 Hz do 100 Hz 1 MΩ CMC 0,035 %\n100 Hz 1 MΩ CMC 0,018 %\n100 Hz do 1 kHz 1 MΩ CMC 0,025 %\n1 kHz 1 MΩ CMC 0,018 %\n1 kHz do 10 kHz 1 MΩ CMC 0,060 %\n10 kHz 1 MΩ CMC 0,050 %\n10 kHz do 100 kHz 1 MΩ CMC 0,50 %\n20 Hz do 100 Hz 10 MΩ CMC 0,10 %\n100 Hz 10 MΩ CMC 0,050 %\n100 Hz do 1 kHz 10 MΩ CMC 0,055 %\n1 kHz 10 MΩ CMC 0,050 %\n1 kHz do 10 kHz 10 MΩ CMC 0,18 %\n20 Hz do 100 Hz 100 MΩ CMC 0,40 %\n100 Hz do 1 kHz 100 MΩ CMC 0,50 %\nPorównanie metodą substytucji lub pomiar bezpośredni wzorca impedancji","reference":"MKE-Z2","norm_bases":["MKE-Z2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł impedancji, rezystancja przy prądzie przemiennym / wzorce, mierniki rezystancji, mostki RLC Wzorcowanie – wielkości elektryczne Porównanie metodą substytucji lub pomiar bezpośredni wzorca impedancji 20 Hz do 50 Hz 100 mΩ CMC 0,30 % 50 Hz do 10 kHz 100 mΩ CMC 0,14 % 20 Hz do 100 Hz 1 Ω CMC 0,035 % 100 Hz 1 Ω CMC 0,015 % 100 Hz do 1 kHz 1 Ω CMC 0,020 % 1 kHz 1 Ω CMC 0,015 % 1 kHz do 10 kHz 1 Ω CMC 0,025 % 10 kHz 1 Ω CMC 0,020 % 10 kHz do 100 kHz 1 Ω CMC 0,090 % 20 Hz do 100 Hz 10 Ω CMC 0,016 % 100 Hz 10 Ω CMC 0,011 % 100 Hz do 1 kHz 10 Ω CMC 0,016 % 1 kHz 10 Ω CMC 0,011 % 1 kHz do 10 kHz 10 Ω CMC 0,016 % 10 kHz 10 Ω CMC 0,011 % 10 kHz do 100 kHz 10 Ω CMC 0,045 % 100 kHz 10 Ω CMC 0,040 % 100 kHz do 1 MHz 10 Ω CMC 0,15 % 20 Hz do 100 Hz 100 Ω CMC 0,016 % 100 Hz 100 Ω CMC 0,011 % 100 Hz do 1 kHz 100 Ω CMC 0,016 % 1 kHz 100 Ω CMC 0,011 % 1 kHz do 10 kHz 100 Ω CMC 0,016 % 10 kHz 100 Ω CMC 0,011 % 10 kHz do 100 kHz 100 Ω CMC 0,040 % 100 kHz 100 Ω CMC 0,035 % 100 kHz do 1 MHz 100 Ω CMC 0,15 % 20 Hz do 100 Hz 1 kΩ CMC 0,016 % 100 Hz 1 kΩ CMC 0,011 % 100 Hz do 1 kHz 1 kΩ CMC 0,016 % 1 kHz 1 kΩ CMC 0,011 % 1 kHz do 10 kHz 1 kΩ CMC 0,016 % 10 kHz 1 kΩ CMC 0,011 % 10 kHz do 100 kHz 1 kΩ CMC 0,040 % 100 kHz 1 kΩ CMC 0,035 % 100 kHz do 1 MHz 1 kΩ CMC 0,15 % 20 Hz do 100 Hz 10 kΩ CMC 0,016 % 100 Hz 10 kΩ CMC 0,011 % 100 Hz do 1 kHz 10 kΩ CMC 0,016 % 1 kHz 10 kΩ CMC 0,011 % 1 kHz do 10 kHz 10 kΩ CMC 0,016 % 10 kHz 10 kΩ CMC 0,011 % 10 kHz do 100 kHz 10 kΩ CMC 0,040 % 100 kHz 10 kΩ CMC 0,035 % 100 kHz do 1 MHz 10 kΩ CMC 0,15 % 20 Hz do 100 Hz 100 kΩ CMC 0,020 % 100 Hz 100 kΩ CMC 0,011 % 100 Hz do 1 kHz 100 kΩ CMC 0,016 % 1 kHz 100 kΩ CMC 0,011 % 1 kHz do 10 kHz 100 kΩ CMC 0,020 % 10 kHz 100 kΩ CMC 0,015 % 10 kHz do 100 kHz 100 kΩ CMC 0,20 % 20 Hz do 100 Hz 1 MΩ CMC 0,035 % 100 Hz 1 MΩ CMC 0,018 % 100 Hz do 1 kHz 1 MΩ CMC 0,025 % 1 kHz 1 MΩ CMC 0,018 % 1 kHz do 10 kHz 1 MΩ CMC 0,060 % 10 kHz 1 MΩ CMC 0,050 % 10 kHz do 100 kHz 1 MΩ CMC 0,50 % 20 Hz do 100 Hz 10 MΩ CMC 0,10 % 100 Hz 10 MΩ CMC 0,050 % 100 Hz do 1 kHz 10 MΩ CMC 0,055 % 1 kHz 10 MΩ CMC 0,050 % 1 kHz do 10 kHz 10 MΩ CMC 0,18 % 20 Hz do 100 Hz 100 MΩ CMC 0,40 % 100 Hz do 1 kHz 100 MΩ CMC 0,50 % Modul impedance, střídavý odpor / etalony, měřidla odporu, RLC mosty Kalibrace – elektrické veličiny Porovnání substitucí nebo přímé měření etalonu impedance 20 Hz až 50 Hz 100 mΩ CMC 0,30 % 50 Hz až 10 kHz 100 mΩ CMC 0,14 % 20 Hz až 100 Hz 1 Ω CMC 0,035 % 100 Hz 1 Ω CMC 0,015 % 100 Hz až 1 kHz 1 Ω CMC 0,020 % 1 kHz 1 Ω CMC 0,015 % 1 kHz až 10 kHz 1 Ω CMC 0,025 % 10 kHz 1 Ω CMC 0,020 % 10 kHz až 100 kHz 1 Ω CMC 0,090 % 20 Hz až 100 Hz 10 Ω CMC 0,016 % 100 Hz 10 Ω CMC 0,011 % 100 Hz až 1 kHz 10 Ω CMC 0,016 % 1 kHz 10 Ω CMC 0,011 % 1 kHz až 10 kHz 10 Ω CMC 0,016 % 10 kHz 10 Ω CMC 0,011 % 10 kHz až 100 kHz 10 Ω CMC 0,045 % 100 kHz 10 Ω CMC 0,040 % 100 kHz až 1 MHz 10 Ω CMC 0,15 % 20 Hz až 100 Hz 100 Ω CMC 0,016 % 100 Hz 100 Ω CMC 0,011 % 100 Hz až 1 kHz 100 Ω CMC 0,016 % 1 kHz 100 Ω CMC 0,011 % 1 kHz až 10 kHz 100 Ω CMC 0,016 % 10 kHz 100 Ω CMC 0,011 % 10 kHz až 100 kHz 100 Ω CMC 0,040 % 100 kHz 100 Ω CMC 0,035 % 100 kHz až 1 MHz 100 Ω CMC 0,15 % 20 Hz až 100 Hz 1 kΩ CMC 0,016 % 100 Hz 1 kΩ CMC 0,011 % 100 Hz až 1 kHz 1 kΩ CMC 0,016 % 1 kHz 1 kΩ CMC 0,011 % 1 kHz až 10 kHz 1 kΩ CMC 0,016 % 10 kHz 1 kΩ CMC 0,011 % 10 kHz až 100 kHz 1 kΩ CMC 0,040 % 100 kHz 1 kΩ CMC 0,035 % 100 kHz až 1 MHz 1 kΩ CMC 0,15 % 20 Hz až 100 Hz 10 kΩ CMC 0,016 % 100 Hz 10 kΩ CMC 0,011 % 100 Hz až 1 kHz 10 kΩ CMC 0,016 % 1 kHz 10 kΩ CMC 0,011 % 1 kHz až 10 kHz 10 kΩ CMC 0,016 % 10 kHz 10 kΩ CMC 0,011 % 10 kHz až 100 kHz 10 kΩ CMC 0,040 % 100 kHz 10 kΩ CMC 0,035 % 100 kHz až 1 MHz 10 kΩ CMC 0,15 % 20 Hz až 100 Hz 100 kΩ CMC 0,020 % 100 Hz 100 kΩ CMC 0,011 % 100 Hz až 1 kHz 100 kΩ CMC 0,016 % 1 kHz 100 kΩ CMC 0,011 % 1 kHz až 10 kHz 100 kΩ CMC 0,020 % 10 kHz 100 kΩ CMC 0,015 % 10 kHz až 100 kHz 100 kΩ CMC 0,20 % 20 Hz až 100 Hz 1 MΩ CMC 0,035 % 100 Hz 1 MΩ CMC 0,018 % 100 Hz až 1 kHz 1 MΩ CMC 0,025 % 1 kHz 1 MΩ CMC 0,018 % 1 kHz až 10 kHz 1 MΩ CMC 0,060 % 10 kHz 1 MΩ CMC 0,050 % 10 kHz až 100 kHz 1 MΩ CMC 0,50 % 20 Hz až 100 Hz 10 MΩ CMC 0,10 % 100 Hz 10 MΩ CMC 0,050 % 100 Hz až 1 kHz 10 MΩ CMC 0,055 % 1 kHz 10 MΩ CMC 0,050 % 1 kHz až 10 kHz 10 MΩ CMC 0,18 % 20 Hz až 100 Hz 100 MΩ CMC 0,40 % 100 Hz až 1 kHz 100 MΩ CMC 0,50 % MKE-Z2 Modul impedancji, rezystancja przy pradzie przemiennym / wzorce, mierniki rezystancji, mostki RLC Wzorcowanie – wielkosci elektryczne Porownanie metoda substytucji lub pomiar bezposredni wzorca impedancji 20 Hz do 50 Hz 100 mΩ CMC 0,30 % 50 Hz do 10 kHz 100 mΩ CMC 0,14 % 20 Hz do 100 Hz 1 Ω CMC 0,035 % 100 Hz 1 Ω CMC 0,015 % 100 Hz do 1 kHz 1 Ω CMC 0,020 % 1 kHz 1 Ω CMC 0,015 % 1 kHz do 10 kHz 1 Ω CMC 0,025 % 10 kHz 1 Ω CMC 0,020 % 10 kHz do 100 kHz 1 Ω CMC 0,090 % 20 Hz do 100 Hz 10 Ω CMC 0,016 % 100 Hz 10 Ω CMC 0,011 % 100 Hz do 1 kHz 10 Ω CMC 0,016 % 1 kHz 10 Ω CMC 0,011 % 1 kHz do 10 kHz 10 Ω CMC 0,016 % 10 kHz 10 Ω CMC 0,011 % 10 kHz do 100 kHz 10 Ω CMC 0,045 % 100 kHz 10 Ω CMC 0,040 % 100 kHz do 1 MHz 10 Ω CMC 0,15 % 20 Hz do 100 Hz 100 Ω CMC 0,016 % 100 Hz 100 Ω CMC 0,011 % 100 Hz do 1 kHz 100 Ω CMC 0,016 % 1 kHz 100 Ω CMC 0,011 % 1 kHz do 10 kHz 100 Ω CMC 0,016 % 10 kHz 100 Ω CMC 0,011 % 10 kHz do 100 kHz 100 Ω CMC 0,040 % 100 kHz 100 Ω CMC 0,035 % 100 kHz do 1 MHz 100 Ω CMC 0,15 % 20 Hz do 100 Hz 1 kΩ CMC 0,016 % 100 Hz 1 kΩ CMC 0,011 % 100 Hz do 1 kHz 1 kΩ CMC 0,016 % 1 kHz 1 kΩ CMC 0,011 % 1 kHz do 10 kHz 1 kΩ CMC 0,016 % 10 kHz 1 kΩ CMC 0,011 % 10 kHz do 100 kHz 1 kΩ CMC 0,040 % 100 kHz 1 kΩ CMC 0,035 % 100 kHz do 1 MHz 1 kΩ CMC 0,15 % 20 Hz do 100 Hz 10 kΩ CMC 0,016 % 100 Hz 10 kΩ CMC 0,011 % 100 Hz do 1 kHz 10 kΩ CMC 0,016 % 1 kHz 10 kΩ CMC 0,011 % 1 kHz do 10 kHz 10 kΩ CMC 0,016 % 10 kHz 10 kΩ CMC 0,011 % 10 kHz do 100 kHz 10 kΩ CMC 0,040 % 100 kHz 10 kΩ CMC 0,035 % 100 kHz do 1 MHz 10 kΩ CMC 0,15 % 20 Hz do 100 Hz 100 kΩ CMC 0,020 % 100 Hz 100 kΩ CMC 0,011 % 100 Hz do 1 kHz 100 kΩ CMC 0,016 % 1 kHz 100 kΩ CMC 0,011 % 1 kHz do 10 kHz 100 kΩ CMC 0,020 % 10 kHz 100 kΩ CMC 0,015 % 10 kHz do 100 kHz 100 kΩ CMC 0,20 % 20 Hz do 100 Hz 1 MΩ CMC 0,035 % 100 Hz 1 MΩ CMC 0,018 % 100 Hz do 1 kHz 1 MΩ CMC 0,025 % 1 kHz 1 MΩ CMC 0,018 % 1 kHz do 10 kHz 1 MΩ CMC 0,060 % 10 kHz 1 MΩ CMC 0,050 % 10 kHz do 100 kHz 1 MΩ CMC 0,50 % 20 Hz do 100 Hz 10 MΩ CMC 0,10 % 100 Hz 10 MΩ CMC 0,050 % 100 Hz do 1 kHz 10 MΩ CMC 0,055 % 1 kHz 10 MΩ CMC 0,050 % 1 kHz do 10 kHz 10 MΩ CMC 0,18 % 20 Hz do 100 Hz 100 MΩ CMC 0,40 % 100 Hz do 1 kHz 100 MΩ CMC 0,50 % Modul impedance, stridavy odpor / etalony, meridla odporu, RLC mosty Kalibrace – elektricke veliciny Porovnani substituci nebo prime mereni etalonu impedance 20 Hz az 50 Hz 100 mΩ CMC 0,30 % 50 Hz az 10 kHz 100 mΩ CMC 0,14 % 20 Hz az 100 Hz 1 Ω CMC 0,035 % 100 Hz 1 Ω CMC 0,015 % 100 Hz az 1 kHz 1 Ω CMC 0,020 % 1 kHz 1 Ω CMC 0,015 % 1 kHz az 10 kHz 1 Ω CMC 0,025 % 10 kHz 1 Ω CMC 0,020 % 10 kHz az 100 kHz 1 Ω CMC 0,090 % 20 Hz az 100 Hz 10 Ω CMC 0,016 % 100 Hz 10 Ω CMC 0,011 % 100 Hz az 1 kHz 10 Ω CMC 0,016 % 1 kHz 10 Ω CMC 0,011 % 1 kHz az 10 kHz 10 Ω CMC 0,016 % 10 kHz 10 Ω CMC 0,011 % 10 kHz az 100 kHz 10 Ω CMC 0,045 % 100 kHz 10 Ω CMC 0,040 % 100 kHz az 1 MHz 10 Ω CMC 0,15 % 20 Hz az 100 Hz 100 Ω CMC 0,016 % 100 Hz 100 Ω CMC 0,011 % 100 Hz az 1 kHz 100 Ω CMC 0,016 % 1 kHz 100 Ω CMC 0,011 % 1 kHz az 10 kHz 100 Ω CMC 0,016 % 10 kHz 100 Ω CMC 0,011 % 10 kHz az 100 kHz 100 Ω CMC 0,040 % 100 kHz 100 Ω CMC 0,035 % 100 kHz az 1 MHz 100 Ω CMC 0,15 % 20 Hz az 100 Hz 1 kΩ CMC 0,016 % 100 Hz 1 kΩ CMC 0,011 % 100 Hz az 1 kHz 1 kΩ CMC 0,016 % 1 kHz 1 kΩ CMC 0,011 % 1 kHz az 10 kHz 1 kΩ CMC 0,016 % 10 kHz 1 kΩ CMC 0,011 % 10 kHz az 100 kHz 1 kΩ CMC 0,040 % 100 kHz 1 kΩ CMC 0,035 % 100 kHz az 1 MHz 1 kΩ CMC 0,15 % 20 Hz az 100 Hz 10 kΩ CMC 0,016 % 100 Hz 10 kΩ CMC 0,011 % 100 Hz az 1 kHz 10 kΩ CMC 0,016 % 1 kHz 10 kΩ CMC 0,011 % 1 kHz az 10 kHz 10 kΩ CMC 0,016 % 10 kHz 10 kΩ CMC 0,011 % 10 kHz az 100 kHz 10 kΩ CMC 0,040 % 100 kHz 10 kΩ CMC 0,035 % 100 kHz az 1 MHz 10 kΩ CMC 0,15 % 20 Hz az 100 Hz 100 kΩ CMC 0,020 % 100 Hz 100 kΩ CMC 0,011 % 100 Hz az 1 kHz 100 kΩ CMC 0,016 % 1 kHz 100 kΩ CMC 0,011 % 1 kHz az 10 kHz 100 kΩ CMC 0,020 % 10 kHz 100 kΩ CMC 0,015 % 10 kHz az 100 kHz 100 kΩ CMC 0,20 % 20 Hz az 100 Hz 1 MΩ CMC 0,035 % 100 Hz 1 MΩ CMC 0,018 % 100 Hz az 1 kHz 1 MΩ CMC 0,025 % 1 kHz 1 MΩ CMC 0,018 % 1 kHz az 10 kHz 1 MΩ CMC 0,060 % 10 kHz 1 MΩ CMC 0,050 % 10 kHz az 100 kHz 1 MΩ CMC 0,50 % 20 Hz az 100 Hz 10 MΩ CMC 0,10 % 100 Hz 10 MΩ CMC 0,050 % 100 Hz az 1 kHz 10 MΩ CMC 0,055 % 1 kHz 10 MΩ CMC 0,050 % 1 kHz az 10 kHz 10 MΩ CMC 0,18 % 20 Hz az 100 Hz 100 MΩ CMC 0,40 % 100 Hz az 1 kHz 100 MΩ CMC 0,50 % MKE-Z2","search_en":"Impedance module, AC resistance / standards, resistance meters, RLC bridges Calibration – electrical quantities Comparison by substitution or direct measurement of impedance standard 20 Hz to 50 Hz 100 mΩ CMC 0,30 % 50 Hz to 10 kHz 100 mΩ CMC 0,14 % 20 Hz to 100 Hz 1 Ω CMC 0,035 % 100 Hz 1 Ω CMC 0,015 % 100 Hz to 1 kHz 1 Ω CMC 0,020 % 1 kHz 1 Ω CMC 0,015 % 1 kHz to 10 kHz 1 Ω CMC 0,025 % 10 kHz 1 Ω CMC 0,020 % 10 kHz to 100 kHz 1 Ω CMC 0,090 % 20 Hz to 100 Hz 10 Ω CMC 0,016 % 100 Hz 10 Ω CMC 0,011 % 100 Hz to 1 kHz 10 Ω CMC 0,016 % 1 kHz 10 Ω CMC 0,011 % 1 kHz to 10 kHz 10 Ω CMC 0,016 % 10 kHz 10 Ω CMC 0,011 % 10 kHz to 100 kHz 10 Ω CMC 0,045 % 100 kHz 10 Ω CMC 0,040 % 100 kHz to 1 MHz 10 Ω CMC 0,15 % 20 Hz to 100 Hz 100 Ω CMC 0,016 % 100 Hz 100 Ω CMC 0,011 % 100 Hz to 1 kHz 100 Ω CMC 0,016 % 1 kHz 100 Ω CMC 0,011 % 1 kHz to 10 kHz 100 Ω CMC 0,016 % 10 kHz 100 Ω CMC 0,011 % 10 kHz to 100 kHz 100 Ω CMC 0,040 % 100 kHz 100 Ω CMC 0,035 % 100 kHz to 1 MHz 100 Ω CMC 0,15 % 20 Hz to 100 Hz 1 kΩ CMC 0,016 % 100 Hz 1 kΩ CMC 0,011 % 100 Hz to 1 kHz 1 kΩ CMC 0,016 % 1 kHz 1 kΩ CMC 0,011 % 1 kHz to 10 kHz 1 kΩ CMC 0,016 % 10 kHz 1 kΩ CMC 0,011 % 10 kHz to 100 kHz 1 kΩ CMC 0,040 % 100 kHz 1 kΩ CMC 0,035 % 100 kHz to 1 MHz 1 kΩ CMC 0,15 % 20 Hz to 100 Hz 10 kΩ CMC 0,016 % 100 Hz 10 kΩ CMC 0,011 % 100 Hz to 1 kHz 10 kΩ CMC 0,016 % 1 kHz 10 kΩ CMC 0,011 % 1 kHz to 10 kHz 10 kΩ CMC 0,016 % 10 kHz 10 kΩ CMC 0,011 % 10 kHz to 100 kHz 10 kΩ CMC 0,040 % 100 kHz 10 kΩ CMC 0,035 % 100 kHz to 1 MHz 10 kΩ CMC 0,15 % 20 Hz to 100 Hz 100 kΩ CMC 0,020 % 100 Hz 100 kΩ CMC 0,011 % 100 Hz to 1 kHz 100 kΩ CMC 0,016 % 1 kHz 100 kΩ CMC 0,011 % 1 kHz to 10 kHz 100 kΩ CMC 0,020 % 10 kHz 100 kΩ CMC 0,015 % 10 kHz to 100 kHz 100 kΩ CMC 0,20 % 20 Hz to 100 Hz 1 MΩ CMC 0,035 % 100 Hz 1 MΩ CMC 0,018 % 100 Hz to 1 kHz 1 MΩ CMC 0,025 % 1 kHz 1 MΩ CMC 0,018 % 1 kHz to 10 kHz 1 MΩ CMC 0,060 % 10 kHz 1 MΩ CMC 0,050 % 10 kHz to 100 kHz 1 MΩ CMC 0,50 % 20 Hz to 100 Hz 10 MΩ CMC 0,10 % 100 Hz 10 MΩ CMC 0,050 % 100 Hz to 1 kHz 10 MΩ CMC 0,055 % 1 kHz 10 MΩ CMC 0,050 % 1 kHz to 10 kHz 10 MΩ CMC 0,18 % 20 Hz to 100 Hz 100 MΩ CMC 0,40 % 100 Hz to 1 kHz 100 MΩ CMC 0,50 % MKE-Z2","search_zh":"阻抗模、交流电阻 / 标准器、电阻测量仪、RLC 电桥 校准 – 电学量 替代法比较或直接测量阻抗标准器 20 Hz 至 50 Hz 100 mΩ CMC 0,30 % 50 Hz 至 10 kHz 100 mΩ CMC 0,14 % 20 Hz 至 100 Hz 1 Ω CMC 0,035 % 100 Hz 1 Ω CMC 0,015 % 100 Hz 至 1 kHz 1 Ω CMC 0,020 % 1 kHz 1 Ω CMC 0,015 % 1 kHz 至 10 kHz 1 Ω CMC 0,025 % 10 kHz 1 Ω CMC 0,020 % 10 kHz 至 100 kHz 1 Ω CMC 0,090 % 20 Hz 至 100 Hz 10 Ω CMC 0,016 % 100 Hz 10 Ω CMC 0,011 % 100 Hz 至 1 kHz 10 Ω CMC 0,016 % 1 kHz 10 Ω CMC 0,011 % 1 kHz 至 10 kHz 10 Ω CMC 0,016 % 10 kHz 10 Ω CMC 0,011 % 10 kHz 至 100 kHz 10 Ω CMC 0,045 % 100 kHz 10 Ω CMC 0,040 % 100 kHz 至 1 MHz 10 Ω CMC 0,15 % 20 Hz 至 100 Hz 100 Ω CMC 0,016 % 100 Hz 100 Ω CMC 0,011 % 100 Hz 至 1 kHz 100 Ω CMC 0,016 % 1 kHz 100 Ω CMC 0,011 % 1 kHz 至 10 kHz 100 Ω CMC 0,016 % 10 kHz 100 Ω CMC 0,011 % 10 kHz 至 100 kHz 100 Ω CMC 0,040 % 100 kHz 100 Ω CMC 0,035 % 100 kHz 至 1 MHz 100 Ω CMC 0,15 % 20 Hz 至 100 Hz 1 kΩ CMC 0,016 % 100 Hz 1 kΩ CMC 0,011 % 100 Hz 至 1 kHz 1 kΩ CMC 0,016 % 1 kHz 1 kΩ CMC 0,011 % 1 kHz 至 10 kHz 1 kΩ CMC 0,016 % 10 kHz 1 kΩ CMC 0,011 % 10 kHz 至 100 kHz 1 kΩ CMC 0,040 % 100 kHz 1 kΩ CMC 0,035 % 100 kHz 至 1 MHz 1 kΩ CMC 0,15 % 20 Hz 至 100 Hz 10 kΩ CMC 0,016 % 100 Hz 10 kΩ CMC 0,011 % 100 Hz 至 1 kHz 10 kΩ CMC 0,016 % 1 kHz 10 kΩ CMC 0,011 % 1 kHz 至 10 kHz 10 kΩ CMC 0,016 % 10 kHz 10 kΩ CMC 0,011 % 10 kHz 至 100 kHz 10 kΩ CMC 0,040 % 100 kHz 10 kΩ CMC 0,035 % 100 kHz 至 1 MHz 10 kΩ CMC 0,15 % 20 Hz 至 100 Hz 100 kΩ CMC 0,020 % 100 Hz 100 kΩ CMC 0,011 % 100 Hz 至 1 kHz 100 kΩ CMC 0,016 % 1 kHz 100 kΩ CMC 0,011 % 1 kHz 至 10 kHz 100 kΩ CMC 0,020 % 10 kHz 100 kΩ CMC 0,015 % 10 kHz 至 100 kHz 100 kΩ CMC 0,20 % 20 Hz 至 100 Hz 1 MΩ CMC 0,035 % 100 Hz 1 MΩ CMC 0,018 % 100 Hz 至 1 kHz 1 MΩ CMC 0,025 % 1 kHz 1 MΩ CMC 0,018 % 1 kHz 至 10 kHz 1 MΩ CMC 0,060 % 10 kHz 1 MΩ CMC 0,050 % 10 kHz 至 100 kHz 1 MΩ CMC 0,50 % 20 Hz 至 100 Hz 10 MΩ CMC 0,10 % 100 Hz 10 MΩ CMC 0,050 % 100 Hz 至 1 kHz 10 MΩ CMC 0,055 % 1 kHz 10 MΩ CMC 0,050 % 1 kHz 至 10 kHz 10 MΩ CMC 0,18 % 20 Hz 至 100 Hz 100 MΩ CMC 0,40 % 100 Hz 至 1 kHz 100 MΩ CMC 0,50 % MKE-Z2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ae82fbf5116448a31ceb2c67","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"15","test_object":"Moduł impedancji, rezystancja przy prądzie przemiennym / wzorce, dekady, mierniki rezystancji, mierniki cęgowe, mierniki do badań instalacji, mostki RLC","test_object_en":"Impedance module, AC resistance / Resistance standards, boxes, meters, clamp meters, inspection meters, RLC bridges","test_object_zh":"阻抗模、交流电阻 / 标准器、电阻箱、电阻测量仪、钳形表、检测仪表、RLC 电桥","test_object_cs":"Modul impedance, střídavý odpor / Etalony, dekády, měřidla odporu, klešťové měřidla, revizní měřidla, RLC mosty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"20 Hz do 50 Hz","range":"od 10 mΩ do 100 mΩ","cmc":"4 mΩ"},{"name":"50 Hz do 100 Hz","range":"od 10 mΩ do 100 mΩ","cmc":"3 mΩ"},{"name":"100 Hz do 500 Hz","range":"od 10 mΩ do 100 mΩ","cmc":"2,2 mΩ"},{"name":"500 Hz do 5 kHz","range":"od 10 mΩ do 100 mΩ","cmc":"1,5 mΩ"},{"name":"5 kHz do 500 kHz","range":"od 10 mΩ do 100 mΩ","cmc":"1 mΩ"},{"name":"500 kHz do 1 MHz","range":"od 10 mΩ do 100 mΩ","cmc":"2 mΩ"},{"name":"20 Hz do 50 Hz","range":"od 100 mΩ do 1000 mΩ","cmc":"7 mΩ"},{"name":"50 Hz do 100 Hz","range":"od 100 mΩ do 1000 mΩ","cmc":"6 mΩ"},{"name":"100 Hz do 500 Hz","range":"od 100 mΩ do 1000 mΩ","cmc":"4 mΩ"},{"name":"500 Hz do 5 kHz","range":"od 100 mΩ do 1000 mΩ","cmc":"3,5 mΩ"},{"name":"5 kHz do 500 kHz","range":"od 100 mΩ do 1000 mΩ","cmc":"3 mΩ"},{"name":"500 kHz do 1 MHz","range":"od 100 mΩ do 1000 mΩ","cmc":"7 mΩ"},{"name":"20 Hz do 50 Hz","range":"od 1 Ω do 10 Ω","cmc":"0,25 % + 0,007 Ω"},{"name":"50 Hz do 100 Hz","range":"od 1 Ω do 10 Ω","cmc":"0,20 % + 0,007 Ω"},{"name":"100 Hz do 500 Hz","range":"od 1 Ω do 10 Ω","cmc":"0,20 % + 0,003 Ω"},{"name":"500 Hz do 5 kHz","range":"od 1 Ω do 10 Ω","cmc":"0,17 % + 0,003 Ω"},{"name":"5 kHz do 100 kHz","range":"od 1 Ω do 10 Ω","cmc":"0,17 % + 0,002 Ω"},{"name":"100 kHz do 500 kHz","range":"od 1 Ω do 10 Ω","cmc":"0,20 % + 0,002 Ω"},{"name":"500 kHz do 1 MHz","range":"od 1 Ω do 10 Ω","cmc":"0,45 % + 0,002 Ω"},{"name":"20 Hz do 100 Hz","range":"od 10 Ω do 100 Ω","cmc":"0,15 % + 0,02 Ω"},{"name":"100 Hz do 500 Hz","range":"od 10 Ω do 100 Ω","cmc":"0,08 % + 0,02 Ω"},{"name":"500 Hz do 100 kHz","range":"od 10 Ω do 100 Ω","cmc":"0,10 % + 0,02 Ω"},{"name":"100 kHz do 500 kHz","range":"od 10 Ω do 100 Ω","cmc":"0,13 % + 0,02 Ω"},{"name":"500 kHz do 1 MHz","range":"od 10 Ω do 100 Ω","cmc":"0,36 % + 0,02 Ω"},{"name":"20 Hz do 100 Hz","range":"od 100 Ω do 1 kΩ","cmc":"0,16 %"},{"name":"100 Hz do 500 Hz","range":"od 100 Ω do 1 kΩ","cmc":"0,10 %"},{"name":"500 Hz do 5 kHz","range":"od 100 Ω do 1 kΩ","cmc":"0,11 %"},{"name":"5 kHz do 100 kHz","range":"od 100 Ω do 1 kΩ","cmc":"0,12 %"},{"name":"100 kHz do 1 MHz","range":"od 100 Ω do 1 kΩ","cmc":"0,17 %"},{"name":"1 MHz","range":"od 100 Ω do 1 kΩ","cmc":"0,35 %"},{"name":"20 Hz do 100 Hz","range":"od 1 kΩ do 10 kΩ","cmc":"0,16 %"},{"name":"100 Hz do 5 kHz","range":"od 1 kΩ do 10 kΩ","cmc":"0,10 %"},{"name":"5 kHz do 100 kHz","range":"od 1 kΩ do 10 kΩ","cmc":"0,12 %"},{"name":"100 kHz do 1 MHz","range":"od 1 kΩ do 10 kΩ","cmc":"0,27 %"},{"name":"1 MHz","range":"od 1 kΩ do 10 kΩ","cmc":"0,55 %"},{"name":"20 Hz do 100 Hz","range":"od 10 kΩ do 100 kΩ","cmc":"0,17 %"},{"name":"100 Hz do 5 kHz","range":"od 10 kΩ do 100 kΩ","cmc":"0,10 %"},{"name":"5 kHz do 10 kHz","range":"od 10 kΩ do 100 kΩ","cmc":"0,18 %"},{"name":"10 kHz do 100 kHz","range":"od 10 kΩ do 100 kΩ","cmc":"0,22 %"},{"name":"100 kHz do 1 MHz","range":"od 10 kΩ do 100 kΩ","cmc":"0,33 %"},{"name":"1 MHz","range":"od 10 kΩ do 100 kΩ","cmc":"0,65 %"},{"name":"20 Hz do 50 Hz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/5 + 0,20) %"},{"name":"50 Hz do 100 Hz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz do 500 Hz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz do 1 kHz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz do 5 kHz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz do 10 kHz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/12 + 0,16) %"},{"name":"10 kHz do 100 kHz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz do 1 MHz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"od 0,1 MΩ do 1 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"50 Hz do 100 Hz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz do 500 Hz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz do 1 kHz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz do 5 kHz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz do 10 kHz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/12 + 0,15) %"},{"name":"10 kHz do 100 kHz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz do 1 MHz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"od 1 MΩ do 10 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"100 Hz do 500 Hz","range":"od 10 MΩ do 100 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz do 1 kHz","range":"od 10 MΩ do 100 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz do 100 kHz","range":"od 10 MΩ do 100 MΩ","cmc":"(R/12 + 0,10) %"}],"parameters_en":[{"name":"20 Hz to 50 Hz","range":"10 mΩ to 100 mΩ","cmc":"4 mΩ"},{"name":"50 Hz to 100 Hz","range":"10 mΩ to 100 mΩ","cmc":"3 mΩ"},{"name":"100 Hz to 500 Hz","range":"10 mΩ to 100 mΩ","cmc":"2,2 mΩ"},{"name":"500 Hz to 5 kHz","range":"10 mΩ to 100 mΩ","cmc":"1,5 mΩ"},{"name":"5 kHz to 500 kHz","range":"10 mΩ to 100 mΩ","cmc":"1 mΩ"},{"name":"500 kHz to 1 MHz","range":"10 mΩ to 100 mΩ","cmc":"2 mΩ"},{"name":"20 Hz to 50 Hz","range":"100 mΩ to 1000 mΩ","cmc":"7 mΩ"},{"name":"50 Hz to 100 Hz","range":"100 mΩ to 1000 mΩ","cmc":"6 mΩ"},{"name":"100 Hz to 500 Hz","range":"100 mΩ to 1000 mΩ","cmc":"4 mΩ"},{"name":"500 Hz to 5 kHz","range":"100 mΩ to 1000 mΩ","cmc":"3,5 mΩ"},{"name":"5 kHz to 500 kHz","range":"100 mΩ to 1000 mΩ","cmc":"3 mΩ"},{"name":"500 kHz to 1 MHz","range":"100 mΩ to 1000 mΩ","cmc":"7 mΩ"},{"name":"20 Hz to 50 Hz","range":"1 Ω to 10 Ω","cmc":"0,25 % + 0,007 Ω"},{"name":"50 Hz to 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,20 % + 0,007 Ω"},{"name":"100 Hz to 500 Hz","range":"1 Ω to 10 Ω","cmc":"0,20 % + 0,003 Ω"},{"name":"500 Hz to 5 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 % + 0,003 Ω"},{"name":"5 kHz to 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 % + 0,002 Ω"},{"name":"100 kHz to 500 kHz","range":"1 Ω to 10 Ω","cmc":"0,20 % + 0,002 Ω"},{"name":"500 kHz to 1 MHz","range":"1 Ω to 10 Ω","cmc":"0,45 % + 0,002 Ω"},{"name":"20 Hz to 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,15 % + 0,02 Ω"},{"name":"100 Hz to 500 Hz","range":"10 Ω to 100 Ω","cmc":"0,08 % + 0,02 Ω"},{"name":"500 Hz to 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,10 % + 0,02 Ω"},{"name":"100 kHz to 500 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 % + 0,02 Ω"},{"name":"500 kHz to 1 MHz","range":"10 Ω to 100 Ω","cmc":"0,36 % + 0,02 Ω"},{"name":"20 Hz to 100 Hz","range":"100 Ω to 1 kΩ","cmc":"0,16 %"},{"name":"100 Hz to 500 Hz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"500 Hz to 5 kHz","range":"100 Ω to 1 kΩ","cmc":"0,11 %"},{"name":"5 kHz to 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,12 %"},{"name":"100 kHz to 1 MHz","range":"100 Ω to 1 kΩ","cmc":"0,17 %"},{"name":"1 MHz","range":"100 Ω to 1 kΩ","cmc":"0,35 %"},{"name":"20 Hz to 100 Hz","range":"1 kΩ to 10 kΩ","cmc":"0,16 %"},{"name":"100 Hz to 5 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,10 %"},{"name":"5 kHz to 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"100 kHz to 1 MHz","range":"1 kΩ to 10 kΩ","cmc":"0,27 %"},{"name":"1 MHz","range":"1 kΩ to 10 kΩ","cmc":"0,55 %"},{"name":"20 Hz to 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,17 %"},{"name":"100 Hz to 5 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,10 %"},{"name":"5 kHz to 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,18 %"},{"name":"10 kHz to 100 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,22 %"},{"name":"100 kHz to 1 MHz","range":"10 kΩ to 100 kΩ","cmc":"0,33 %"},{"name":"1 MHz","range":"10 kΩ to 100 kΩ","cmc":"0,65 %"},{"name":"20 Hz to 50 Hz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/5 + 0,20) %"},{"name":"50 Hz to 100 Hz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz to 500 Hz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz to 1 kHz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz to 5 kHz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz to 10 kHz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/12 + 0,16) %"},{"name":"10 kHz to 100 kHz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz to 1 MHz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"0,1 MΩ to 1 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"50 Hz to 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz to 500 Hz","range":"1 MΩ to 10 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz to 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz to 5 kHz","range":"1 MΩ to 10 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz to 10 kHz","range":"1 MΩ to 10 MΩ","cmc":"(R/12 + 0,15) %"},{"name":"10 kHz to 100 kHz","range":"1 MΩ to 10 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz to 1 MHz","range":"1 MΩ to 10 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"1 MΩ to 10 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"100 Hz to 500 Hz","range":"10 MΩ to 100 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz to 1 kHz","range":"10 MΩ to 100 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz to 100 kHz","range":"10 MΩ to 100 MΩ","cmc":"(R/12 + 0,10) %"}],"parameters_zh":[{"name":"20 Hz 至 50 Hz","range":"10 mΩ 至 100 mΩ","cmc":"4 mΩ"},{"name":"50 Hz 至 100 Hz","range":"10 mΩ 至 100 mΩ","cmc":"3 mΩ"},{"name":"100 Hz 至 500 Hz","range":"10 mΩ 至 100 mΩ","cmc":"2,2 mΩ"},{"name":"500 Hz 至 5 kHz","range":"10 mΩ 至 100 mΩ","cmc":"1,5 mΩ"},{"name":"5 kHz 至 500 kHz","range":"10 mΩ 至 100 mΩ","cmc":"1 mΩ"},{"name":"500 kHz 至 1 MHz","range":"10 mΩ 至 100 mΩ","cmc":"2 mΩ"},{"name":"20 Hz 至 50 Hz","range":"100 mΩ 至 1000 mΩ","cmc":"7 mΩ"},{"name":"50 Hz 至 100 Hz","range":"100 mΩ 至 1000 mΩ","cmc":"6 mΩ"},{"name":"100 Hz 至 500 Hz","range":"100 mΩ 至 1000 mΩ","cmc":"4 mΩ"},{"name":"500 Hz 至 5 kHz","range":"100 mΩ 至 1000 mΩ","cmc":"3,5 mΩ"},{"name":"5 kHz 至 500 kHz","range":"100 mΩ 至 1000 mΩ","cmc":"3 mΩ"},{"name":"500 kHz 至 1 MHz","range":"100 mΩ 至 1000 mΩ","cmc":"7 mΩ"},{"name":"20 Hz 至 50 Hz","range":"1 Ω 至 10 Ω","cmc":"0,25 % + 0,007 Ω"},{"name":"50 Hz 至 100 Hz","range":"1 Ω 至 10 Ω","cmc":"0,20 % + 0,007 Ω"},{"name":"100 Hz 至 500 Hz","range":"1 Ω 至 10 Ω","cmc":"0,20 % + 0,003 Ω"},{"name":"500 Hz 至 5 kHz","range":"1 Ω 至 10 Ω","cmc":"0,17 % + 0,003 Ω"},{"name":"5 kHz 至 100 kHz","range":"1 Ω 至 10 Ω","cmc":"0,17 % + 0,002 Ω"},{"name":"100 kHz 至 500 kHz","range":"1 Ω 至 10 Ω","cmc":"0,20 % + 0,002 Ω"},{"name":"500 kHz 至 1 MHz","range":"1 Ω 至 10 Ω","cmc":"0,45 % + 0,002 Ω"},{"name":"20 Hz 至 100 Hz","range":"10 Ω 至 100 Ω","cmc":"0,15 % + 0,02 Ω"},{"name":"100 Hz 至 500 Hz","range":"10 Ω 至 100 Ω","cmc":"0,08 % + 0,02 Ω"},{"name":"500 Hz 至 100 kHz","range":"10 Ω 至 100 Ω","cmc":"0,10 % + 0,02 Ω"},{"name":"100 kHz 至 500 kHz","range":"10 Ω 至 100 Ω","cmc":"0,13 % + 0,02 Ω"},{"name":"500 kHz 至 1 MHz","range":"10 Ω 至 100 Ω","cmc":"0,36 % + 0,02 Ω"},{"name":"20 Hz 至 100 Hz","range":"100 Ω 至 1 kΩ","cmc":"0,16 %"},{"name":"100 Hz 至 500 Hz","range":"100 Ω 至 1 kΩ","cmc":"0,10 %"},{"name":"500 Hz 至 5 kHz","range":"100 Ω 至 1 kΩ","cmc":"0,11 %"},{"name":"5 kHz 至 100 kHz","range":"100 Ω 至 1 kΩ","cmc":"0,12 %"},{"name":"100 kHz 至 1 MHz","range":"100 Ω 至 1 kΩ","cmc":"0,17 %"},{"name":"1 MHz","range":"100 Ω 至 1 kΩ","cmc":"0,35 %"},{"name":"20 Hz 至 100 Hz","range":"1 kΩ 至 10 kΩ","cmc":"0,16 %"},{"name":"100 Hz 至 5 kHz","range":"1 kΩ 至 10 kΩ","cmc":"0,10 %"},{"name":"5 kHz 至 100 kHz","range":"1 kΩ 至 10 kΩ","cmc":"0,12 %"},{"name":"100 kHz 至 1 MHz","range":"1 kΩ 至 10 kΩ","cmc":"0,27 %"},{"name":"1 MHz","range":"1 kΩ 至 10 kΩ","cmc":"0,55 %"},{"name":"20 Hz 至 100 Hz","range":"10 kΩ 至 100 kΩ","cmc":"0,17 %"},{"name":"100 Hz 至 5 kHz","range":"10 kΩ 至 100 kΩ","cmc":"0,10 %"},{"name":"5 kHz 至 10 kHz","range":"10 kΩ 至 100 kΩ","cmc":"0,18 %"},{"name":"10 kHz 至 100 kHz","range":"10 kΩ 至 100 kΩ","cmc":"0,22 %"},{"name":"100 kHz 至 1 MHz","range":"10 kΩ 至 100 kΩ","cmc":"0,33 %"},{"name":"1 MHz","range":"10 kΩ 至 100 kΩ","cmc":"0,65 %"},{"name":"20 Hz 至 50 Hz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/5 + 0,20) %"},{"name":"50 Hz 至 100 Hz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz 至 500 Hz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz 至 1 kHz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz 至 5 kHz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz 至 10 kHz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/12 + 0,16) %"},{"name":"10 kHz 至 100 kHz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz 至 1 MHz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"0,1 MΩ 至 1 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"50 Hz 至 100 Hz","range":"1 MΩ 至 10 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz 至 500 Hz","range":"1 MΩ 至 10 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz 至 1 kHz","range":"1 MΩ 至 10 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz 至 5 kHz","range":"1 MΩ 至 10 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz 至 10 kHz","range":"1 MΩ 至 10 MΩ","cmc":"(R/12 + 0,15) %"},{"name":"10 kHz 至 100 kHz","range":"1 MΩ 至 10 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz 至 1 MHz","range":"1 MΩ 至 10 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"1 MΩ 至 10 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"100 Hz 至 500 Hz","range":"10 MΩ 至 100 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz 至 1 kHz","range":"10 MΩ 至 100 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz 至 100 kHz","range":"10 MΩ 至 100 MΩ","cmc":"(R/12 + 0,10) %"}],"parameters_cs":[{"name":"20 Hz až 50 Hz","range":"10 mΩ až 100 mΩ","cmc":"4 mΩ"},{"name":"50 Hz až 100 Hz","range":"10 mΩ až 100 mΩ","cmc":"3 mΩ"},{"name":"100 Hz až 500 Hz","range":"10 mΩ až 100 mΩ","cmc":"2,2 mΩ"},{"name":"500 Hz až 5 kHz","range":"10 mΩ až 100 mΩ","cmc":"1,5 mΩ"},{"name":"5 kHz až 500 kHz","range":"10 mΩ až 100 mΩ","cmc":"1 mΩ"},{"name":"500 kHz až 1 MHz","range":"10 mΩ až 100 mΩ","cmc":"2 mΩ"},{"name":"20 Hz až 50 Hz","range":"100 mΩ až 1000 mΩ","cmc":"7 mΩ"},{"name":"50 Hz až 100 Hz","range":"100 mΩ až 1000 mΩ","cmc":"6 mΩ"},{"name":"100 Hz až 500 Hz","range":"100 mΩ až 1000 mΩ","cmc":"4 mΩ"},{"name":"500 Hz až 5 kHz","range":"100 mΩ až 1000 mΩ","cmc":"3,5 mΩ"},{"name":"5 kHz až 500 kHz","range":"100 mΩ až 1000 mΩ","cmc":"3 mΩ"},{"name":"500 kHz až 1 MHz","range":"100 mΩ až 1000 mΩ","cmc":"7 mΩ"},{"name":"20 Hz až 50 Hz","range":"1 Ω až 10 Ω","cmc":"0,25 % + 0,007 Ω"},{"name":"50 Hz až 100 Hz","range":"1 Ω až 10 Ω","cmc":"0,20 % + 0,007 Ω"},{"name":"100 Hz až 500 Hz","range":"1 Ω až 10 Ω","cmc":"0,20 % + 0,003 Ω"},{"name":"500 Hz až 5 kHz","range":"1 Ω až 10 Ω","cmc":"0,17 % + 0,003 Ω"},{"name":"5 kHz až 100 kHz","range":"1 Ω až 10 Ω","cmc":"0,17 % + 0,002 Ω"},{"name":"100 kHz až 500 kHz","range":"1 Ω až 10 Ω","cmc":"0,20 % + 0,002 Ω"},{"name":"500 kHz až 1 MHz","range":"1 Ω až 10 Ω","cmc":"0,45 % + 0,002 Ω"},{"name":"20 Hz až 100 Hz","range":"10 Ω až 100 Ω","cmc":"0,15 % + 0,02 Ω"},{"name":"100 Hz až 500 Hz","range":"10 Ω až 100 Ω","cmc":"0,08 % + 0,02 Ω"},{"name":"500 Hz až 100 kHz","range":"10 Ω až 100 Ω","cmc":"0,10 % + 0,02 Ω"},{"name":"100 kHz až 500 kHz","range":"10 Ω až 100 Ω","cmc":"0,13 % + 0,02 Ω"},{"name":"500 kHz až 1 MHz","range":"10 Ω až 100 Ω","cmc":"0,36 % + 0,02 Ω"},{"name":"20 Hz až 100 Hz","range":"100 Ω až 1 kΩ","cmc":"0,16 %"},{"name":"100 Hz až 500 Hz","range":"100 Ω až 1 kΩ","cmc":"0,10 %"},{"name":"500 Hz až 5 kHz","range":"100 Ω až 1 kΩ","cmc":"0,11 %"},{"name":"5 kHz až 100 kHz","range":"100 Ω až 1 kΩ","cmc":"0,12 %"},{"name":"100 kHz až 1 MHz","range":"100 Ω až 1 kΩ","cmc":"0,17 %"},{"name":"1 MHz","range":"100 Ω až 1 kΩ","cmc":"0,35 %"},{"name":"20 Hz až 100 Hz","range":"1 kΩ až 10 kΩ","cmc":"0,16 %"},{"name":"100 Hz až 5 kHz","range":"1 kΩ až 10 kΩ","cmc":"0,10 %"},{"name":"5 kHz až 100 kHz","range":"1 kΩ až 10 kΩ","cmc":"0,12 %"},{"name":"100 kHz až 1 MHz","range":"1 kΩ až 10 kΩ","cmc":"0,27 %"},{"name":"1 MHz","range":"1 kΩ až 10 kΩ","cmc":"0,55 %"},{"name":"20 Hz až 100 Hz","range":"10 kΩ až 100 kΩ","cmc":"0,17 %"},{"name":"100 Hz až 5 kHz","range":"10 kΩ až 100 kΩ","cmc":"0,10 %"},{"name":"5 kHz až 10 kHz","range":"10 kΩ až 100 kΩ","cmc":"0,18 %"},{"name":"10 kHz až 100 kHz","range":"10 kΩ až 100 kΩ","cmc":"0,22 %"},{"name":"100 kHz až 1 MHz","range":"10 kΩ až 100 kΩ","cmc":"0,33 %"},{"name":"1 MHz","range":"10 kΩ až 100 kΩ","cmc":"0,65 %"},{"name":"20 Hz až 50 Hz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/5 + 0,20) %"},{"name":"50 Hz až 100 Hz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz až 500 Hz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz až 1 kHz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz až 5 kHz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz až 10 kHz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/12 + 0,16) %"},{"name":"10 kHz až 100 kHz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz až 1 MHz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"0,1 MΩ až 1 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"50 Hz až 100 Hz","range":"1 MΩ až 10 MΩ","cmc":"(R/6 + 0,15) %"},{"name":"100 Hz až 500 Hz","range":"1 MΩ až 10 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz až 1 kHz","range":"1 MΩ až 10 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz až 5 kHz","range":"1 MΩ až 10 MΩ","cmc":"(R/12 + 0,10) %"},{"name":"5 kHz až 10 kHz","range":"1 MΩ až 10 MΩ","cmc":"(R/12 + 0,15) %"},{"name":"10 kHz až 100 kHz","range":"1 MΩ až 10 MΩ","cmc":"(R/15 + 0,26) %"},{"name":"100 kHz až 1 MHz","range":"1 MΩ až 10 MΩ","cmc":"(R/1,6 + 0,30) %"},{"name":"1 MHz","range":"1 MΩ až 10 MΩ","cmc":"(R/0,8 + 0,60) %"},{"name":"100 Hz až 500 Hz","range":"10 MΩ až 100 MΩ","cmc":"(R/8 + 0,10) %"},{"name":"500 Hz až 1 kHz","range":"10 MΩ až 100 MΩ","cmc":"(R/10 + 0,10) %"},{"name":"1 kHz až 100 kHz","range":"10 MΩ až 100 MΩ","cmc":"(R/12 + 0,10) %"}],"technique":"Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC","technique_en":"Direct measurement or comparison by substitution with a reference RLC bridge","technique_zh":"直接测量或用标准RLC电桥替代法比较","technique_cs":"Přímé měření nebo porovnání substitucí s etalonovým RLC mostem","techniques":["Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC"],"techniques_en":["Direct measurement or comparison by substitution with a reference RLC bridge"],"techniques_zh":["直接测量或用标准RLC电桥替代法比较"],"techniques_cs":["Přímé měření nebo porovnání substitucí s etalonovým RLC mostem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n20 Hz do 50 Hz od 10 mΩ do 100 mΩ CMC 4 mΩ\n50 Hz do 100 Hz od 10 mΩ do 100 mΩ CMC 3 mΩ\n100 Hz do 500 Hz od 10 mΩ do 100 mΩ CMC 2,2 mΩ\n500 Hz do 5 kHz od 10 mΩ do 100 mΩ CMC 1,5 mΩ\n5 kHz do 500 kHz od 10 mΩ do 100 mΩ CMC 1 mΩ\n500 kHz do 1 MHz od 10 mΩ do 100 mΩ CMC 2 mΩ\n20 Hz do 50 Hz od 100 mΩ do 1000 mΩ CMC 7 mΩ\n50 Hz do 100 Hz od 100 mΩ do 1000 mΩ CMC 6 mΩ\n100 Hz do 500 Hz od 100 mΩ do 1000 mΩ CMC 4 mΩ\n500 Hz do 5 kHz od 100 mΩ do 1000 mΩ CMC 3,5 mΩ\n5 kHz do 500 kHz od 100 mΩ do 1000 mΩ CMC 3 mΩ\n500 kHz do 1 MHz od 100 mΩ do 1000 mΩ CMC 7 mΩ\n20 Hz do 50 Hz od 1 Ω do 10 Ω CMC 0,25 % + 0,007 Ω\n50 Hz do 100 Hz od 1 Ω do 10 Ω CMC 0,20 % + 0,007 Ω\n100 Hz do 500 Hz od 1 Ω do 10 Ω CMC 0,20 % + 0,003 Ω\n500 Hz do 5 kHz od 1 Ω do 10 Ω CMC 0,17 % + 0,003 Ω\n5 kHz do 100 kHz od 1 Ω do 10 Ω CMC 0,17 % + 0,002 Ω\n100 kHz do 500 kHz od 1 Ω do 10 Ω CMC 0,20 % + 0,002 Ω\n500 kHz do 1 MHz od 1 Ω do 10 Ω CMC 0,45 % + 0,002 Ω\n20 Hz do 100 Hz od 10 Ω do 100 Ω CMC 0,15 % + 0,02 Ω\n100 Hz do 500 Hz od 10 Ω do 100 Ω CMC 0,08 % + 0,02 Ω\n500 Hz do 100 kHz od 10 Ω do 100 Ω CMC 0,10 % + 0,02 Ω\n100 kHz do 500 kHz od 10 Ω do 100 Ω CMC 0,13 % + 0,02 Ω\n500 kHz do 1 MHz od 10 Ω do 100 Ω CMC 0,36 % + 0,02 Ω\n20 Hz do 100 Hz od 100 Ω do 1 kΩ CMC 0,16 %\n100 Hz do 500 Hz od 100 Ω do 1 kΩ CMC 0,10 %\n500 Hz do 5 kHz od 100 Ω do 1 kΩ CMC 0,11 %\n5 kHz do 100 kHz od 100 Ω do 1 kΩ CMC 0,12 %\n100 kHz do 1 MHz od 100 Ω do 1 kΩ CMC 0,17 %\n1 MHz od 100 Ω do 1 kΩ CMC 0,35 %\n20 Hz do 100 Hz od 1 kΩ do 10 kΩ CMC 0,16 %\n100 Hz do 5 kHz od 1 kΩ do 10 kΩ CMC 0,10 %\n5 kHz do 100 kHz od 1 kΩ do 10 kΩ CMC 0,12 %\n100 kHz do 1 MHz od 1 kΩ do 10 kΩ CMC 0,27 %\n1 MHz od 1 kΩ do 10 kΩ CMC 0,55 %\n20 Hz do 100 Hz od 10 kΩ do 100 kΩ CMC 0,17 %\n100 Hz do 5 kHz od 10 kΩ do 100 kΩ CMC 0,10 %\n5 kHz do 10 kHz od 10 kΩ do 100 kΩ CMC 0,18 %\n10 kHz do 100 kHz od 10 kΩ do 100 kΩ CMC 0,22 %\n100 kHz do 1 MHz od 10 kΩ do 100 kΩ CMC 0,33 %\n1 MHz od 10 kΩ do 100 kΩ CMC 0,65 %\n20 Hz do 50 Hz od 0,1 MΩ do 1 MΩ CMC (R/5 + 0,20) %\n50 Hz do 100 Hz od 0,1 MΩ do 1 MΩ CMC (R/6 + 0,15) %\n100 Hz do 500 Hz od 0,1 MΩ do 1 MΩ CMC (R/8 + 0,10) %\n500 Hz do 1 kHz od 0,1 MΩ do 1 MΩ CMC (R/10 + 0,10) %\n1 kHz do 5 kHz od 0,1 MΩ do 1 MΩ CMC (R/12 + 0,10) %\n5 kHz do 10 kHz od 0,1 MΩ do 1 MΩ CMC (R/12 + 0,16) %\n10 kHz do 100 kHz od 0,1 MΩ do 1 MΩ CMC (R/15 + 0,26) %\n100 kHz do 1 MHz od 0,1 MΩ do 1 MΩ CMC (R/1,6 + 0,30) %\n1 MHz od 0,1 MΩ do 1 MΩ CMC (R/0,8 + 0,60) %\n50 Hz do 100 Hz od 1 MΩ do 10 MΩ CMC (R/6 + 0,15) %\n100 Hz do 500 Hz od 1 MΩ do 10 MΩ CMC (R/8 + 0,10) %\n500 Hz do 1 kHz od 1 MΩ do 10 MΩ CMC (R/10 + 0,10) %\n1 kHz do 5 kHz od 1 MΩ do 10 MΩ CMC (R/12 + 0,10) %\n5 kHz do 10 kHz od 1 MΩ do 10 MΩ CMC (R/12 + 0,15) %\n10 kHz do 100 kHz od 1 MΩ do 10 MΩ CMC (R/15 + 0,26) %\n100 kHz do 1 MHz od 1 MΩ do 10 MΩ CMC (R/1,6 + 0,30) %\n1 MHz od 1 MΩ do 10 MΩ CMC (R/0,8 + 0,60) %\n100 Hz do 500 Hz od 10 MΩ do 100 MΩ CMC (R/8 + 0,10) %\n500 Hz do 1 kHz od 10 MΩ do 100 MΩ CMC (R/10 + 0,10) %\n1 kHz do 100 kHz od 10 MΩ do 100 MΩ CMC (R/12 + 0,10) %\nPomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC","reference":"MKE-Z2","norm_bases":["MKE-Z2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduł impedancji, rezystancja przy prądzie przemiennym / wzorce, dekady, mierniki rezystancji, mierniki cęgowe, mierniki do badań instalacji, mostki RLC Wzorcowanie – wielkości elektryczne Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC 20 Hz do 50 Hz od 10 mΩ do 100 mΩ CMC 4 mΩ 50 Hz do 100 Hz od 10 mΩ do 100 mΩ CMC 3 mΩ 100 Hz do 500 Hz od 10 mΩ do 100 mΩ CMC 2,2 mΩ 500 Hz do 5 kHz od 10 mΩ do 100 mΩ CMC 1,5 mΩ 5 kHz do 500 kHz od 10 mΩ do 100 mΩ CMC 1 mΩ 500 kHz do 1 MHz od 10 mΩ do 100 mΩ CMC 2 mΩ 20 Hz do 50 Hz od 100 mΩ do 1000 mΩ CMC 7 mΩ 50 Hz do 100 Hz od 100 mΩ do 1000 mΩ CMC 6 mΩ 100 Hz do 500 Hz od 100 mΩ do 1000 mΩ CMC 4 mΩ 500 Hz do 5 kHz od 100 mΩ do 1000 mΩ CMC 3,5 mΩ 5 kHz do 500 kHz od 100 mΩ do 1000 mΩ CMC 3 mΩ 500 kHz do 1 MHz od 100 mΩ do 1000 mΩ CMC 7 mΩ 20 Hz do 50 Hz od 1 Ω do 10 Ω CMC 0,25 % + 0,007 Ω 50 Hz do 100 Hz od 1 Ω do 10 Ω CMC 0,20 % + 0,007 Ω 100 Hz do 500 Hz od 1 Ω do 10 Ω CMC 0,20 % + 0,003 Ω 500 Hz do 5 kHz od 1 Ω do 10 Ω CMC 0,17 % + 0,003 Ω 5 kHz do 100 kHz od 1 Ω do 10 Ω CMC 0,17 % + 0,002 Ω 100 kHz do 500 kHz od 1 Ω do 10 Ω CMC 0,20 % + 0,002 Ω 500 kHz do 1 MHz od 1 Ω do 10 Ω CMC 0,45 % + 0,002 Ω 20 Hz do 100 Hz od 10 Ω do 100 Ω CMC 0,15 % + 0,02 Ω 100 Hz do 500 Hz od 10 Ω do 100 Ω CMC 0,08 % + 0,02 Ω 500 Hz do 100 kHz od 10 Ω do 100 Ω CMC 0,10 % + 0,02 Ω 100 kHz do 500 kHz od 10 Ω do 100 Ω CMC 0,13 % + 0,02 Ω 500 kHz do 1 MHz od 10 Ω do 100 Ω CMC 0,36 % + 0,02 Ω 20 Hz do 100 Hz od 100 Ω do 1 kΩ CMC 0,16 % 100 Hz do 500 Hz od 100 Ω do 1 kΩ CMC 0,10 % 500 Hz do 5 kHz od 100 Ω do 1 kΩ CMC 0,11 % 5 kHz do 100 kHz od 100 Ω do 1 kΩ CMC 0,12 % 100 kHz do 1 MHz od 100 Ω do 1 kΩ CMC 0,17 % 1 MHz od 100 Ω do 1 kΩ CMC 0,35 % 20 Hz do 100 Hz od 1 kΩ do 10 kΩ CMC 0,16 % 100 Hz do 5 kHz od 1 kΩ do 10 kΩ CMC 0,10 % 5 kHz do 100 kHz od 1 kΩ do 10 kΩ CMC 0,12 % 100 kHz do 1 MHz od 1 kΩ do 10 kΩ CMC 0,27 % 1 MHz od 1 kΩ do 10 kΩ CMC 0,55 % 20 Hz do 100 Hz od 10 kΩ do 100 kΩ CMC 0,17 % 100 Hz do 5 kHz od 10 kΩ do 100 kΩ CMC 0,10 % 5 kHz do 10 kHz od 10 kΩ do 100 kΩ CMC 0,18 % 10 kHz do 100 kHz od 10 kΩ do 100 kΩ CMC 0,22 % 100 kHz do 1 MHz od 10 kΩ do 100 kΩ CMC 0,33 % 1 MHz od 10 kΩ do 100 kΩ CMC 0,65 % 20 Hz do 50 Hz od 0,1 MΩ do 1 MΩ CMC (R/5 + 0,20) % 50 Hz do 100 Hz od 0,1 MΩ do 1 MΩ CMC (R/6 + 0,15) % 100 Hz do 500 Hz od 0,1 MΩ do 1 MΩ CMC (R/8 + 0,10) % 500 Hz do 1 kHz od 0,1 MΩ do 1 MΩ CMC (R/10 + 0,10) % 1 kHz do 5 kHz od 0,1 MΩ do 1 MΩ CMC (R/12 + 0,10) % 5 kHz do 10 kHz od 0,1 MΩ do 1 MΩ CMC (R/12 + 0,16) % 10 kHz do 100 kHz od 0,1 MΩ do 1 MΩ CMC (R/15 + 0,26) % 100 kHz do 1 MHz od 0,1 MΩ do 1 MΩ CMC (R/1,6 + 0,30) % 1 MHz od 0,1 MΩ do 1 MΩ CMC (R/0,8 + 0,60) % 50 Hz do 100 Hz od 1 MΩ do 10 MΩ CMC (R/6 + 0,15) % 100 Hz do 500 Hz od 1 MΩ do 10 MΩ CMC (R/8 + 0,10) % 500 Hz do 1 kHz od 1 MΩ do 10 MΩ CMC (R/10 + 0,10) % 1 kHz do 5 kHz od 1 MΩ do 10 MΩ CMC (R/12 + 0,10) % 5 kHz do 10 kHz od 1 MΩ do 10 MΩ CMC (R/12 + 0,15) % 10 kHz do 100 kHz od 1 MΩ do 10 MΩ CMC (R/15 + 0,26) % 100 kHz do 1 MHz od 1 MΩ do 10 MΩ CMC (R/1,6 + 0,30) % 1 MHz od 1 MΩ do 10 MΩ CMC (R/0,8 + 0,60) % 100 Hz do 500 Hz od 10 MΩ do 100 MΩ CMC (R/8 + 0,10) % 500 Hz do 1 kHz od 10 MΩ do 100 MΩ CMC (R/10 + 0,10) % 1 kHz do 100 kHz od 10 MΩ do 100 MΩ CMC (R/12 + 0,10) % Modul impedance, střídavý odpor / Etalony, dekády, měřidla odporu, klešťové měřidla, revizní měřidla, RLC mosty Kalibrace – elektrické veličiny Přímé měření nebo porovnání substitucí s etalonovým RLC mostem 20 Hz až 50 Hz 10 mΩ až 100 mΩ CMC 4 mΩ 50 Hz až 100 Hz 10 mΩ až 100 mΩ CMC 3 mΩ 100 Hz až 500 Hz 10 mΩ až 100 mΩ CMC 2,2 mΩ 500 Hz až 5 kHz 10 mΩ až 100 mΩ CMC 1,5 mΩ 5 kHz až 500 kHz 10 mΩ až 100 mΩ CMC 1 mΩ 500 kHz až 1 MHz 10 mΩ až 100 mΩ CMC 2 mΩ 20 Hz až 50 Hz 100 mΩ až 1000 mΩ CMC 7 mΩ 50 Hz až 100 Hz 100 mΩ až 1000 mΩ CMC 6 mΩ 100 Hz až 500 Hz 100 mΩ až 1000 mΩ CMC 4 mΩ 500 Hz až 5 kHz 100 mΩ až 1000 mΩ CMC 3,5 mΩ 5 kHz až 500 kHz 100 mΩ až 1000 mΩ CMC 3 mΩ 500 kHz až 1 MHz 100 mΩ až 1000 mΩ CMC 7 mΩ 20 Hz až 50 Hz 1 Ω až 10 Ω CMC 0,25 % + 0,007 Ω 50 Hz až 100 Hz 1 Ω až 10 Ω CMC 0,20 % + 0,007 Ω 100 Hz až 500 Hz 1 Ω až 10 Ω CMC 0,20 % + 0,003 Ω 500 Hz až 5 kHz 1 Ω až 10 Ω CMC 0,17 % + 0,003 Ω 5 kHz až 100 kHz 1 Ω až 10 Ω CMC 0,17 % + 0,002 Ω 100 kHz až 500 kHz 1 Ω až 10 Ω CMC 0,20 % + 0,002 Ω 500 kHz až 1 MHz 1 Ω až 10 Ω CMC 0,45 % + 0,002 Ω 20 Hz až 100 Hz 10 Ω až 100 Ω CMC 0,15 % + 0,02 Ω 100 Hz až 500 Hz 10 Ω až 100 Ω CMC 0,08 % + 0,02 Ω 500 Hz až 100 kHz 10 Ω až 100 Ω CMC 0,10 % + 0,02 Ω 100 kHz až 500 kHz 10 Ω až 100 Ω CMC 0,13 % + 0,02 Ω 500 kHz až 1 MHz 10 Ω až 100 Ω CMC 0,36 % + 0,02 Ω 20 Hz až 100 Hz 100 Ω až 1 kΩ CMC 0,16 % 100 Hz až 500 Hz 100 Ω až 1 kΩ CMC 0,10 % 500 Hz až 5 kHz 100 Ω až 1 kΩ CMC 0,11 % 5 kHz až 100 kHz 100 Ω až 1 kΩ CMC 0,12 % 100 kHz až 1 MHz 100 Ω až 1 kΩ CMC 0,17 % 1 MHz 100 Ω až 1 kΩ CMC 0,35 % 20 Hz až 100 Hz 1 kΩ až 10 kΩ CMC 0,16 % 100 Hz až 5 kHz 1 kΩ až 10 kΩ CMC 0,10 % 5 kHz až 100 kHz 1 kΩ až 10 kΩ CMC 0,12 % 100 kHz až 1 MHz 1 kΩ až 10 kΩ CMC 0,27 % 1 MHz 1 kΩ až 10 kΩ CMC 0,55 % 20 Hz až 100 Hz 10 kΩ až 100 kΩ CMC 0,17 % 100 Hz až 5 kHz 10 kΩ až 100 kΩ CMC 0,10 % 5 kHz až 10 kHz 10 kΩ až 100 kΩ CMC 0,18 % 10 kHz až 100 kHz 10 kΩ až 100 kΩ CMC 0,22 % 100 kHz až 1 MHz 10 kΩ až 100 kΩ CMC 0,33 % 1 MHz 10 kΩ až 100 kΩ CMC 0,65 % 20 Hz až 50 Hz 0,1 MΩ až 1 MΩ CMC (R/5 + 0,20) % 50 Hz až 100 Hz 0,1 MΩ až 1 MΩ CMC (R/6 + 0,15) % 100 Hz až 500 Hz 0,1 MΩ až 1 MΩ CMC (R/8 + 0,10) % 500 Hz až 1 kHz 0,1 MΩ až 1 MΩ CMC (R/10 + 0,10) % 1 kHz až 5 kHz 0,1 MΩ až 1 MΩ CMC (R/12 + 0,10) % 5 kHz až 10 kHz 0,1 MΩ až 1 MΩ CMC (R/12 + 0,16) % 10 kHz až 100 kHz 0,1 MΩ až 1 MΩ CMC (R/15 + 0,26) % 100 kHz až 1 MHz 0,1 MΩ až 1 MΩ CMC (R/1,6 + 0,30) % 1 MHz 0,1 MΩ až 1 MΩ CMC (R/0,8 + 0,60) % 50 Hz až 100 Hz 1 MΩ až 10 MΩ CMC (R/6 + 0,15) % 100 Hz až 500 Hz 1 MΩ až 10 MΩ CMC (R/8 + 0,10) % 500 Hz až 1 kHz 1 MΩ až 10 MΩ CMC (R/10 + 0,10) % 1 kHz až 5 kHz 1 MΩ až 10 MΩ CMC (R/12 + 0,10) % 5 kHz až 10 kHz 1 MΩ až 10 MΩ CMC (R/12 + 0,15) % 10 kHz až 100 kHz 1 MΩ až 10 MΩ CMC (R/15 + 0,26) % 100 kHz až 1 MHz 1 MΩ až 10 MΩ CMC (R/1,6 + 0,30) % 1 MHz 1 MΩ až 10 MΩ CMC (R/0,8 + 0,60) % 100 Hz až 500 Hz 10 MΩ až 100 MΩ CMC (R/8 + 0,10) % 500 Hz až 1 kHz 10 MΩ až 100 MΩ CMC (R/10 + 0,10) % 1 kHz až 100 kHz 10 MΩ až 100 MΩ CMC (R/12 + 0,10) % MKE-Z2 Modul impedancji, rezystancja przy pradzie przemiennym / wzorce, dekady, mierniki rezystancji, mierniki cegowe, mierniki do badan instalacji, mostki RLC Wzorcowanie – wielkosci elektryczne Pomiar bezposredni lub porownanie metoda substytucji z wzorcowym mostkiem RLC 20 Hz do 50 Hz od 10 mΩ do 100 mΩ CMC 4 mΩ 50 Hz do 100 Hz od 10 mΩ do 100 mΩ CMC 3 mΩ 100 Hz do 500 Hz od 10 mΩ do 100 mΩ CMC 2,2 mΩ 500 Hz do 5 kHz od 10 mΩ do 100 mΩ CMC 1,5 mΩ 5 kHz do 500 kHz od 10 mΩ do 100 mΩ CMC 1 mΩ 500 kHz do 1 MHz od 10 mΩ do 100 mΩ CMC 2 mΩ 20 Hz do 50 Hz od 100 mΩ do 1000 mΩ CMC 7 mΩ 50 Hz do 100 Hz od 100 mΩ do 1000 mΩ CMC 6 mΩ 100 Hz do 500 Hz od 100 mΩ do 1000 mΩ CMC 4 mΩ 500 Hz do 5 kHz od 100 mΩ do 1000 mΩ CMC 3,5 mΩ 5 kHz do 500 kHz od 100 mΩ do 1000 mΩ CMC 3 mΩ 500 kHz do 1 MHz od 100 mΩ do 1000 mΩ CMC 7 mΩ 20 Hz do 50 Hz od 1 Ω do 10 Ω CMC 0,25 % + 0,007 Ω 50 Hz do 100 Hz od 1 Ω do 10 Ω CMC 0,20 % + 0,007 Ω 100 Hz do 500 Hz od 1 Ω do 10 Ω CMC 0,20 % + 0,003 Ω 500 Hz do 5 kHz od 1 Ω do 10 Ω CMC 0,17 % + 0,003 Ω 5 kHz do 100 kHz od 1 Ω do 10 Ω CMC 0,17 % + 0,002 Ω 100 kHz do 500 kHz od 1 Ω do 10 Ω CMC 0,20 % + 0,002 Ω 500 kHz do 1 MHz od 1 Ω do 10 Ω CMC 0,45 % + 0,002 Ω 20 Hz do 100 Hz od 10 Ω do 100 Ω CMC 0,15 % + 0,02 Ω 100 Hz do 500 Hz od 10 Ω do 100 Ω CMC 0,08 % + 0,02 Ω 500 Hz do 100 kHz od 10 Ω do 100 Ω CMC 0,10 % + 0,02 Ω 100 kHz do 500 kHz od 10 Ω do 100 Ω CMC 0,13 % + 0,02 Ω 500 kHz do 1 MHz od 10 Ω do 100 Ω CMC 0,36 % + 0,02 Ω 20 Hz do 100 Hz od 100 Ω do 1 kΩ CMC 0,16 % 100 Hz do 500 Hz od 100 Ω do 1 kΩ CMC 0,10 % 500 Hz do 5 kHz od 100 Ω do 1 kΩ CMC 0,11 % 5 kHz do 100 kHz od 100 Ω do 1 kΩ CMC 0,12 % 100 kHz do 1 MHz od 100 Ω do 1 kΩ CMC 0,17 % 1 MHz od 100 Ω do 1 kΩ CMC 0,35 % 20 Hz do 100 Hz od 1 kΩ do 10 kΩ CMC 0,16 % 100 Hz do 5 kHz od 1 kΩ do 10 kΩ CMC 0,10 % 5 kHz do 100 kHz od 1 kΩ do 10 kΩ CMC 0,12 % 100 kHz do 1 MHz od 1 kΩ do 10 kΩ CMC 0,27 % 1 MHz od 1 kΩ do 10 kΩ CMC 0,55 % 20 Hz do 100 Hz od 10 kΩ do 100 kΩ CMC 0,17 % 100 Hz do 5 kHz od 10 kΩ do 100 kΩ CMC 0,10 % 5 kHz do 10 kHz od 10 kΩ do 100 kΩ CMC 0,18 % 10 kHz do 100 kHz od 10 kΩ do 100 kΩ CMC 0,22 % 100 kHz do 1 MHz od 10 kΩ do 100 kΩ CMC 0,33 % 1 MHz od 10 kΩ do 100 kΩ CMC 0,65 % 20 Hz do 50 Hz od 0,1 MΩ do 1 MΩ CMC (R/5 + 0,20) % 50 Hz do 100 Hz od 0,1 MΩ do 1 MΩ CMC (R/6 + 0,15) % 100 Hz do 500 Hz od 0,1 MΩ do 1 MΩ CMC (R/8 + 0,10) % 500 Hz do 1 kHz od 0,1 MΩ do 1 MΩ CMC (R/10 + 0,10) % 1 kHz do 5 kHz od 0,1 MΩ do 1 MΩ CMC (R/12 + 0,10) % 5 kHz do 10 kHz od 0,1 MΩ do 1 MΩ CMC (R/12 + 0,16) % 10 kHz do 100 kHz od 0,1 MΩ do 1 MΩ CMC (R/15 + 0,26) % 100 kHz do 1 MHz od 0,1 MΩ do 1 MΩ CMC (R/1,6 + 0,30) % 1 MHz od 0,1 MΩ do 1 MΩ CMC (R/0,8 + 0,60) % 50 Hz do 100 Hz od 1 MΩ do 10 MΩ CMC (R/6 + 0,15) % 100 Hz do 500 Hz od 1 MΩ do 10 MΩ CMC (R/8 + 0,10) % 500 Hz do 1 kHz od 1 MΩ do 10 MΩ CMC (R/10 + 0,10) % 1 kHz do 5 kHz od 1 MΩ do 10 MΩ CMC (R/12 + 0,10) % 5 kHz do 10 kHz od 1 MΩ do 10 MΩ CMC (R/12 + 0,15) % 10 kHz do 100 kHz od 1 MΩ do 10 MΩ CMC (R/15 + 0,26) % 100 kHz do 1 MHz od 1 MΩ do 10 MΩ CMC (R/1,6 + 0,30) % 1 MHz od 1 MΩ do 10 MΩ CMC (R/0,8 + 0,60) % 100 Hz do 500 Hz od 10 MΩ do 100 MΩ CMC (R/8 + 0,10) % 500 Hz do 1 kHz od 10 MΩ do 100 MΩ CMC (R/10 + 0,10) % 1 kHz do 100 kHz od 10 MΩ do 100 MΩ CMC (R/12 + 0,10) % Modul impedance, stridavy odpor / Etalony, dekady, meridla odporu, klestove meridla, revizni meridla, RLC mosty Kalibrace – elektricke veliciny Prime mereni nebo porovnani substituci s etalonovym RLC mostem 20 Hz az 50 Hz 10 mΩ az 100 mΩ CMC 4 mΩ 50 Hz az 100 Hz 10 mΩ az 100 mΩ CMC 3 mΩ 100 Hz az 500 Hz 10 mΩ az 100 mΩ CMC 2,2 mΩ 500 Hz az 5 kHz 10 mΩ az 100 mΩ CMC 1,5 mΩ 5 kHz az 500 kHz 10 mΩ az 100 mΩ CMC 1 mΩ 500 kHz az 1 MHz 10 mΩ az 100 mΩ CMC 2 mΩ 20 Hz az 50 Hz 100 mΩ az 1000 mΩ CMC 7 mΩ 50 Hz az 100 Hz 100 mΩ az 1000 mΩ CMC 6 mΩ 100 Hz az 500 Hz 100 mΩ az 1000 mΩ CMC 4 mΩ 500 Hz az 5 kHz 100 mΩ az 1000 mΩ CMC 3,5 mΩ 5 kHz az 500 kHz 100 mΩ az 1000 mΩ CMC 3 mΩ 500 kHz az 1 MHz 100 mΩ az 1000 mΩ CMC 7 mΩ 20 Hz az 50 Hz 1 Ω az 10 Ω CMC 0,25 % + 0,007 Ω 50 Hz az 100 Hz 1 Ω az 10 Ω CMC 0,20 % + 0,007 Ω 100 Hz az 500 Hz 1 Ω az 10 Ω CMC 0,20 % + 0,003 Ω 500 Hz az 5 kHz 1 Ω az 10 Ω CMC 0,17 % + 0,003 Ω 5 kHz az 100 kHz 1 Ω az 10 Ω CMC 0,17 % + 0,002 Ω 100 kHz az 500 kHz 1 Ω az 10 Ω CMC 0,20 % + 0,002 Ω 500 kHz az 1 MHz 1 Ω az 10 Ω CMC 0,45 % + 0,002 Ω 20 Hz az 100 Hz 10 Ω az 100 Ω CMC 0,15 % + 0,02 Ω 100 Hz az 500 Hz 10 Ω az 100 Ω CMC 0,08 % + 0,02 Ω 500 Hz az 100 kHz 10 Ω az 100 Ω CMC 0,10 % + 0,02 Ω 100 kHz az 500 kHz 10 Ω az 100 Ω CMC 0,13 % + 0,02 Ω 500 kHz az 1 MHz 10 Ω az 100 Ω CMC 0,36 % + 0,02 Ω 20 Hz az 100 Hz 100 Ω az 1 kΩ CMC 0,16 % 100 Hz az 500 Hz 100 Ω az 1 kΩ CMC 0,10 % 500 Hz az 5 kHz 100 Ω az 1 kΩ CMC 0,11 % 5 kHz az 100 kHz 100 Ω az 1 kΩ CMC 0,12 % 100 kHz az 1 MHz 100 Ω az 1 kΩ CMC 0,17 % 1 MHz 100 Ω az 1 kΩ CMC 0,35 % 20 Hz az 100 Hz 1 kΩ az 10 kΩ CMC 0,16 % 100 Hz az 5 kHz 1 kΩ az 10 kΩ CMC 0,10 % 5 kHz az 100 kHz 1 kΩ az 10 kΩ CMC 0,12 % 100 kHz az 1 MHz 1 kΩ az 10 kΩ CMC 0,27 % 1 MHz 1 kΩ az 10 kΩ CMC 0,55 % 20 Hz az 100 Hz 10 kΩ az 100 kΩ CMC 0,17 % 100 Hz az 5 kHz 10 kΩ az 100 kΩ CMC 0,10 % 5 kHz az 10 kHz 10 kΩ az 100 kΩ CMC 0,18 % 10 kHz az 100 kHz 10 kΩ az 100 kΩ CMC 0,22 % 100 kHz az 1 MHz 10 kΩ az 100 kΩ CMC 0,33 % 1 MHz 10 kΩ az 100 kΩ CMC 0,65 % 20 Hz az 50 Hz 0,1 MΩ az 1 MΩ CMC (R/5 + 0,20) % 50 Hz az 100 Hz 0,1 MΩ az 1 MΩ CMC (R/6 + 0,15) % 100 Hz az 500 Hz 0,1 MΩ az 1 MΩ CMC (R/8 + 0,10) % 500 Hz az 1 kHz 0,1 MΩ az 1 MΩ CMC (R/10 + 0,10) % 1 kHz az 5 kHz 0,1 MΩ az 1 MΩ CMC (R/12 + 0,10) % 5 kHz az 10 kHz 0,1 MΩ az 1 MΩ CMC (R/12 + 0,16) % 10 kHz az 100 kHz 0,1 MΩ az 1 MΩ CMC (R/15 + 0,26) % 100 kHz az 1 MHz 0,1 MΩ az 1 MΩ CMC (R/1,6 + 0,30) % 1 MHz 0,1 MΩ az 1 MΩ CMC (R/0,8 + 0,60) % 50 Hz az 100 Hz 1 MΩ az 10 MΩ CMC (R/6 + 0,15) % 100 Hz az 500 Hz 1 MΩ az 10 MΩ CMC (R/8 + 0,10) % 500 Hz az 1 kHz 1 MΩ az 10 MΩ CMC (R/10 + 0,10) % 1 kHz az 5 kHz 1 MΩ az 10 MΩ CMC (R/12 + 0,10) % 5 kHz az 10 kHz 1 MΩ az 10 MΩ CMC (R/12 + 0,15) % 10 kHz az 100 kHz 1 MΩ az 10 MΩ CMC (R/15 + 0,26) % 100 kHz az 1 MHz 1 MΩ az 10 MΩ CMC (R/1,6 + 0,30) % 1 MHz 1 MΩ az 10 MΩ CMC (R/0,8 + 0,60) % 100 Hz az 500 Hz 10 MΩ az 100 MΩ CMC (R/8 + 0,10) % 500 Hz az 1 kHz 10 MΩ az 100 MΩ CMC (R/10 + 0,10) % 1 kHz az 100 kHz 10 MΩ az 100 MΩ CMC (R/12 + 0,10) % MKE-Z2","search_en":"Impedance module, AC resistance / Resistance standards, boxes, meters, clamp meters, inspection meters, RLC bridges Calibration – electrical quantities Direct measurement or comparison by substitution with a reference RLC bridge 20 Hz to 50 Hz 10 mΩ to 100 mΩ CMC 4 mΩ 50 Hz to 100 Hz 10 mΩ to 100 mΩ CMC 3 mΩ 100 Hz to 500 Hz 10 mΩ to 100 mΩ CMC 2,2 mΩ 500 Hz to 5 kHz 10 mΩ to 100 mΩ CMC 1,5 mΩ 5 kHz to 500 kHz 10 mΩ to 100 mΩ CMC 1 mΩ 500 kHz to 1 MHz 10 mΩ to 100 mΩ CMC 2 mΩ 20 Hz to 50 Hz 100 mΩ to 1000 mΩ CMC 7 mΩ 50 Hz to 100 Hz 100 mΩ to 1000 mΩ CMC 6 mΩ 100 Hz to 500 Hz 100 mΩ to 1000 mΩ CMC 4 mΩ 500 Hz to 5 kHz 100 mΩ to 1000 mΩ CMC 3,5 mΩ 5 kHz to 500 kHz 100 mΩ to 1000 mΩ CMC 3 mΩ 500 kHz to 1 MHz 100 mΩ to 1000 mΩ CMC 7 mΩ 20 Hz to 50 Hz 1 Ω to 10 Ω CMC 0,25 % + 0,007 Ω 50 Hz to 100 Hz 1 Ω to 10 Ω CMC 0,20 % + 0,007 Ω 100 Hz to 500 Hz 1 Ω to 10 Ω CMC 0,20 % + 0,003 Ω 500 Hz to 5 kHz 1 Ω to 10 Ω CMC 0,17 % + 0,003 Ω 5 kHz to 100 kHz 1 Ω to 10 Ω CMC 0,17 % + 0,002 Ω 100 kHz to 500 kHz 1 Ω to 10 Ω CMC 0,20 % + 0,002 Ω 500 kHz to 1 MHz 1 Ω to 10 Ω CMC 0,45 % + 0,002 Ω 20 Hz to 100 Hz 10 Ω to 100 Ω CMC 0,15 % + 0,02 Ω 100 Hz to 500 Hz 10 Ω to 100 Ω CMC 0,08 % + 0,02 Ω 500 Hz to 100 kHz 10 Ω to 100 Ω CMC 0,10 % + 0,02 Ω 100 kHz to 500 kHz 10 Ω to 100 Ω CMC 0,13 % + 0,02 Ω 500 kHz to 1 MHz 10 Ω to 100 Ω CMC 0,36 % + 0,02 Ω 20 Hz to 100 Hz 100 Ω to 1 kΩ CMC 0,16 % 100 Hz to 500 Hz 100 Ω to 1 kΩ CMC 0,10 % 500 Hz to 5 kHz 100 Ω to 1 kΩ CMC 0,11 % 5 kHz to 100 kHz 100 Ω to 1 kΩ CMC 0,12 % 100 kHz to 1 MHz 100 Ω to 1 kΩ CMC 0,17 % 1 MHz 100 Ω to 1 kΩ CMC 0,35 % 20 Hz to 100 Hz 1 kΩ to 10 kΩ CMC 0,16 % 100 Hz to 5 kHz 1 kΩ to 10 kΩ CMC 0,10 % 5 kHz to 100 kHz 1 kΩ to 10 kΩ CMC 0,12 % 100 kHz to 1 MHz 1 kΩ to 10 kΩ CMC 0,27 % 1 MHz 1 kΩ to 10 kΩ CMC 0,55 % 20 Hz to 100 Hz 10 kΩ to 100 kΩ CMC 0,17 % 100 Hz to 5 kHz 10 kΩ to 100 kΩ CMC 0,10 % 5 kHz to 10 kHz 10 kΩ to 100 kΩ CMC 0,18 % 10 kHz to 100 kHz 10 kΩ to 100 kΩ CMC 0,22 % 100 kHz to 1 MHz 10 kΩ to 100 kΩ CMC 0,33 % 1 MHz 10 kΩ to 100 kΩ CMC 0,65 % 20 Hz to 50 Hz 0,1 MΩ to 1 MΩ CMC (R/5 + 0,20) % 50 Hz to 100 Hz 0,1 MΩ to 1 MΩ CMC (R/6 + 0,15) % 100 Hz to 500 Hz 0,1 MΩ to 1 MΩ CMC (R/8 + 0,10) % 500 Hz to 1 kHz 0,1 MΩ to 1 MΩ CMC (R/10 + 0,10) % 1 kHz to 5 kHz 0,1 MΩ to 1 MΩ CMC (R/12 + 0,10) % 5 kHz to 10 kHz 0,1 MΩ to 1 MΩ CMC (R/12 + 0,16) % 10 kHz to 100 kHz 0,1 MΩ to 1 MΩ CMC (R/15 + 0,26) % 100 kHz to 1 MHz 0,1 MΩ to 1 MΩ CMC (R/1,6 + 0,30) % 1 MHz 0,1 MΩ to 1 MΩ CMC (R/0,8 + 0,60) % 50 Hz to 100 Hz 1 MΩ to 10 MΩ CMC (R/6 + 0,15) % 100 Hz to 500 Hz 1 MΩ to 10 MΩ CMC (R/8 + 0,10) % 500 Hz to 1 kHz 1 MΩ to 10 MΩ CMC (R/10 + 0,10) % 1 kHz to 5 kHz 1 MΩ to 10 MΩ CMC (R/12 + 0,10) % 5 kHz to 10 kHz 1 MΩ to 10 MΩ CMC (R/12 + 0,15) % 10 kHz to 100 kHz 1 MΩ to 10 MΩ CMC (R/15 + 0,26) % 100 kHz to 1 MHz 1 MΩ to 10 MΩ CMC (R/1,6 + 0,30) % 1 MHz 1 MΩ to 10 MΩ CMC (R/0,8 + 0,60) % 100 Hz to 500 Hz 10 MΩ to 100 MΩ CMC (R/8 + 0,10) % 500 Hz to 1 kHz 10 MΩ to 100 MΩ CMC (R/10 + 0,10) % 1 kHz to 100 kHz 10 MΩ to 100 MΩ CMC (R/12 + 0,10) % MKE-Z2","search_zh":"阻抗模、交流电阻 / 标准器、电阻箱、电阻测量仪、钳形表、检测仪表、RLC 电桥 校准 – 电学量 直接测量或用标准RLC电桥替代法比较 20 Hz 至 50 Hz 10 mΩ 至 100 mΩ CMC 4 mΩ 50 Hz 至 100 Hz 10 mΩ 至 100 mΩ CMC 3 mΩ 100 Hz 至 500 Hz 10 mΩ 至 100 mΩ CMC 2,2 mΩ 500 Hz 至 5 kHz 10 mΩ 至 100 mΩ CMC 1,5 mΩ 5 kHz 至 500 kHz 10 mΩ 至 100 mΩ CMC 1 mΩ 500 kHz 至 1 MHz 10 mΩ 至 100 mΩ CMC 2 mΩ 20 Hz 至 50 Hz 100 mΩ 至 1000 mΩ CMC 7 mΩ 50 Hz 至 100 Hz 100 mΩ 至 1000 mΩ CMC 6 mΩ 100 Hz 至 500 Hz 100 mΩ 至 1000 mΩ CMC 4 mΩ 500 Hz 至 5 kHz 100 mΩ 至 1000 mΩ CMC 3,5 mΩ 5 kHz 至 500 kHz 100 mΩ 至 1000 mΩ CMC 3 mΩ 500 kHz 至 1 MHz 100 mΩ 至 1000 mΩ CMC 7 mΩ 20 Hz 至 50 Hz 1 Ω 至 10 Ω CMC 0,25 % + 0,007 Ω 50 Hz 至 100 Hz 1 Ω 至 10 Ω CMC 0,20 % + 0,007 Ω 100 Hz 至 500 Hz 1 Ω 至 10 Ω CMC 0,20 % + 0,003 Ω 500 Hz 至 5 kHz 1 Ω 至 10 Ω CMC 0,17 % + 0,003 Ω 5 kHz 至 100 kHz 1 Ω 至 10 Ω CMC 0,17 % + 0,002 Ω 100 kHz 至 500 kHz 1 Ω 至 10 Ω CMC 0,20 % + 0,002 Ω 500 kHz 至 1 MHz 1 Ω 至 10 Ω CMC 0,45 % + 0,002 Ω 20 Hz 至 100 Hz 10 Ω 至 100 Ω CMC 0,15 % + 0,02 Ω 100 Hz 至 500 Hz 10 Ω 至 100 Ω CMC 0,08 % + 0,02 Ω 500 Hz 至 100 kHz 10 Ω 至 100 Ω CMC 0,10 % + 0,02 Ω 100 kHz 至 500 kHz 10 Ω 至 100 Ω CMC 0,13 % + 0,02 Ω 500 kHz 至 1 MHz 10 Ω 至 100 Ω CMC 0,36 % + 0,02 Ω 20 Hz 至 100 Hz 100 Ω 至 1 kΩ CMC 0,16 % 100 Hz 至 500 Hz 100 Ω 至 1 kΩ CMC 0,10 % 500 Hz 至 5 kHz 100 Ω 至 1 kΩ CMC 0,11 % 5 kHz 至 100 kHz 100 Ω 至 1 kΩ CMC 0,12 % 100 kHz 至 1 MHz 100 Ω 至 1 kΩ CMC 0,17 % 1 MHz 100 Ω 至 1 kΩ CMC 0,35 % 20 Hz 至 100 Hz 1 kΩ 至 10 kΩ CMC 0,16 % 100 Hz 至 5 kHz 1 kΩ 至 10 kΩ CMC 0,10 % 5 kHz 至 100 kHz 1 kΩ 至 10 kΩ CMC 0,12 % 100 kHz 至 1 MHz 1 kΩ 至 10 kΩ CMC 0,27 % 1 MHz 1 kΩ 至 10 kΩ CMC 0,55 % 20 Hz 至 100 Hz 10 kΩ 至 100 kΩ CMC 0,17 % 100 Hz 至 5 kHz 10 kΩ 至 100 kΩ CMC 0,10 % 5 kHz 至 10 kHz 10 kΩ 至 100 kΩ CMC 0,18 % 10 kHz 至 100 kHz 10 kΩ 至 100 kΩ CMC 0,22 % 100 kHz 至 1 MHz 10 kΩ 至 100 kΩ CMC 0,33 % 1 MHz 10 kΩ 至 100 kΩ CMC 0,65 % 20 Hz 至 50 Hz 0,1 MΩ 至 1 MΩ CMC (R/5 + 0,20) % 50 Hz 至 100 Hz 0,1 MΩ 至 1 MΩ CMC (R/6 + 0,15) % 100 Hz 至 500 Hz 0,1 MΩ 至 1 MΩ CMC (R/8 + 0,10) % 500 Hz 至 1 kHz 0,1 MΩ 至 1 MΩ CMC (R/10 + 0,10) % 1 kHz 至 5 kHz 0,1 MΩ 至 1 MΩ CMC (R/12 + 0,10) % 5 kHz 至 10 kHz 0,1 MΩ 至 1 MΩ CMC (R/12 + 0,16) % 10 kHz 至 100 kHz 0,1 MΩ 至 1 MΩ CMC (R/15 + 0,26) % 100 kHz 至 1 MHz 0,1 MΩ 至 1 MΩ CMC (R/1,6 + 0,30) % 1 MHz 0,1 MΩ 至 1 MΩ CMC (R/0,8 + 0,60) % 50 Hz 至 100 Hz 1 MΩ 至 10 MΩ CMC (R/6 + 0,15) % 100 Hz 至 500 Hz 1 MΩ 至 10 MΩ CMC (R/8 + 0,10) % 500 Hz 至 1 kHz 1 MΩ 至 10 MΩ CMC (R/10 + 0,10) % 1 kHz 至 5 kHz 1 MΩ 至 10 MΩ CMC (R/12 + 0,10) % 5 kHz 至 10 kHz 1 MΩ 至 10 MΩ CMC (R/12 + 0,15) % 10 kHz 至 100 kHz 1 MΩ 至 10 MΩ CMC (R/15 + 0,26) % 100 kHz 至 1 MHz 1 MΩ 至 10 MΩ CMC (R/1,6 + 0,30) % 1 MHz 1 MΩ 至 10 MΩ CMC (R/0,8 + 0,60) % 100 Hz 至 500 Hz 10 MΩ 至 100 MΩ CMC (R/8 + 0,10) % 500 Hz 至 1 kHz 10 MΩ 至 100 MΩ CMC (R/10 + 0,10) % 1 kHz 至 100 kHz 10 MΩ 至 100 MΩ CMC (R/12 + 0,10) % MKE-Z2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7dbe15226fe6bd5dd1f9305b","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"16","test_object":"Pojemność / wzorce pojemności, mierniki pojemności, mostki RLC","test_object_en":"Capacitance / Capacitance standards, capacitance meters, RLC bridges","test_object_zh":"电容 / 电容标准器、电容测量仪、RLC 电桥","test_object_cs":"Kapacita / Etalony kapacity, měřidla kapacity, RLC mosty,","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 1 kHz","range":"10 pF","cmc":"0,15 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,075 %"},{"name":"1 kHz do 10 kHz","range":"10 pF","cmc":"0,080 %"},{"name":"10 kHz","range":"10 pF","cmc":"0,040 %"},{"name":"10 kHz do 100 kHz","range":"10 pF","cmc":"0,050 %"},{"name":"100kHz do 1 MHz","range":"10 pF","cmc":"0,15 %"},{"name":"50 Hz do 100 Hz","range":"100 pF","cmc":"0,080 %"},{"name":"100 Hz","range":"100 pF","cmc":"0,050 %"},{"name":"100 Hz do 1 kHz","range":"100 pF","cmc":"0,060 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"1 kHz do 10 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"10 kHz do 100 kHz","range":"100 pF","cmc":"0,050 %"},{"name":"100 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"100 kHz do 1 MHz","range":"100 pF","cmc":"0,15 %"},{"name":"50 Hz do 100 Hz","range":"1 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"1 nF","cmc":"0,035 %"},{"name":"100 Hz do 1 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz do 10 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"10 kHz do 100 kHz","range":"1 nF","cmc":"0,050 %"},{"name":"100 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"100 kHz do 1 MHz","range":"1 nF","cmc":"0,15 %"},{"name":"50 Hz do 100 Hz","range":"10 nF","cmc":"0,050 %"},{"name":"100 Hz","range":"10 nF","cmc":"0,035 %"},{"name":"100 Hz do 1 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"1 kHz do 10 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"10 kHz do 100 kHz","range":"10 nF","cmc":"0,060 %"},{"name":"100 kHz do 1 MHz","range":"10 nF","cmc":"0,15 %"},{"name":"50 Hz do 100 Hz","range":"100 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"100 nF","cmc":"0,035 %"},{"name":"100 Hz do 1 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"1 kHz do 10 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"10 kHz do 100 kHz","range":"100 nF","cmc":"0,060 %"},{"name":"100 kHz do 1 MHz","range":"100 nF","cmc":"0,85 %"},{"name":"20 Hz do 100 Hz","range":"1 µF","cmc":"0,050 %"},{"name":"100 Hz","range":"1 µF","cmc":"0,035 %"},{"name":"100 Hz do 1 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"1 kHz do 10 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"10 kHz do 100 kHz","range":"1 µF","cmc":"0,090 %"},{"name":"20 Hz do 1 kHz","range":"10 µF","cmc":"0,15 %"},{"name":"1 kHz do 10 kHz","range":"10 µF","cmc":"0,20 %"},{"name":"20 Hz do 100 Hz","range":"100 µF","cmc":"0,15 %"},{"name":"100 Hz do 1 kHz","range":"100 µF","cmc":"0,20 %"},{"name":"1 kHz do 10 kHz","range":"100 µF","cmc":"0,40 %"}],"parameters_en":[{"name":"50 Hz to 1 kHz","range":"10 pF","cmc":"0,15 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,075 %"},{"name":"1 kHz to 10 kHz","range":"10 pF","cmc":"0,080 %"},{"name":"10 kHz","range":"10 pF","cmc":"0,040 %"},{"name":"10 kHz to 100 kHz","range":"10 pF","cmc":"0,050 %"},{"name":"100kHz to 1 MHz","range":"10 pF","cmc":"0,15 %"},{"name":"50 Hz to 100 Hz","range":"100 pF","cmc":"0,080 %"},{"name":"100 Hz","range":"100 pF","cmc":"0,050 %"},{"name":"100 Hz to 1 kHz","range":"100 pF","cmc":"0,060 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"1 kHz to 10 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"10 kHz to 100 kHz","range":"100 pF","cmc":"0,050 %"},{"name":"100 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"100 kHz to 1 MHz","range":"100 pF","cmc":"0,15 %"},{"name":"50 Hz to 100 Hz","range":"1 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"1 nF","cmc":"0,035 %"},{"name":"100 Hz to 1 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz to 10 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"10 kHz to 100 kHz","range":"1 nF","cmc":"0,050 %"},{"name":"100 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"100 kHz to 1 MHz","range":"1 nF","cmc":"0,15 %"},{"name":"50 Hz to 100 Hz","range":"10 nF","cmc":"0,050 %"},{"name":"100 Hz","range":"10 nF","cmc":"0,035 %"},{"name":"100 Hz to 1 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"1 kHz to 10 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"10 kHz to 100 kHz","range":"10 nF","cmc":"0,060 %"},{"name":"100 kHz to 1 MHz","range":"10 nF","cmc":"0,15 %"},{"name":"50 Hz to 100 Hz","range":"100 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"100 nF","cmc":"0,035 %"},{"name":"100 Hz to 1 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"1 kHz to 10 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"10 kHz to 100 kHz","range":"100 nF","cmc":"0,060 %"},{"name":"100 kHz to 1 MHz","range":"100 nF","cmc":"0,85 %"},{"name":"20 Hz to 100 Hz","range":"1 µF","cmc":"0,050 %"},{"name":"100 Hz","range":"1 µF","cmc":"0,035 %"},{"name":"100 Hz to 1 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"1 kHz to 10 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"10 kHz to 100 kHz","range":"1 µF","cmc":"0,090 %"},{"name":"20 Hz to 1 kHz","range":"10 µF","cmc":"0,15 %"},{"name":"1 kHz to 10 kHz","range":"10 µF","cmc":"0,20 %"},{"name":"20 Hz to 100 Hz","range":"100 µF","cmc":"0,15 %"},{"name":"100 Hz to 1 kHz","range":"100 µF","cmc":"0,20 %"},{"name":"1 kHz to 10 kHz","range":"100 µF","cmc":"0,40 %"}],"parameters_zh":[{"name":"50 Hz 至 1 kHz","range":"10 pF","cmc":"0,15 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,075 %"},{"name":"1 kHz 至 10 kHz","range":"10 pF","cmc":"0,080 %"},{"name":"10 kHz","range":"10 pF","cmc":"0,040 %"},{"name":"10 kHz 至 100 kHz","range":"10 pF","cmc":"0,050 %"},{"name":"100kHz 至 1 MHz","range":"10 pF","cmc":"0,15 %"},{"name":"50 Hz 至 100 Hz","range":"100 pF","cmc":"0,080 %"},{"name":"100 Hz","range":"100 pF","cmc":"0,050 %"},{"name":"100 Hz 至 1 kHz","range":"100 pF","cmc":"0,060 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"1 kHz 至 10 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"10 kHz 至 100 kHz","range":"100 pF","cmc":"0,050 %"},{"name":"100 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"100 kHz 至 1 MHz","range":"100 pF","cmc":"0,15 %"},{"name":"50 Hz 至 100 Hz","range":"1 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"1 nF","cmc":"0,035 %"},{"name":"100 Hz 至 1 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz 至 10 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"10 kHz 至 100 kHz","range":"1 nF","cmc":"0,050 %"},{"name":"100 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"100 kHz 至 1 MHz","range":"1 nF","cmc":"0,15 %"},{"name":"50 Hz 至 100 Hz","range":"10 nF","cmc":"0,050 %"},{"name":"100 Hz","range":"10 nF","cmc":"0,035 %"},{"name":"100 Hz 至 1 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"1 kHz 至 10 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"10 kHz 至 100 kHz","range":"10 nF","cmc":"0,060 %"},{"name":"100 kHz 至 1 MHz","range":"10 nF","cmc":"0,15 %"},{"name":"50 Hz 至 100 Hz","range":"100 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"100 nF","cmc":"0,035 %"},{"name":"100 Hz 至 1 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"1 kHz 至 10 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"10 kHz 至 100 kHz","range":"100 nF","cmc":"0,060 %"},{"name":"100 kHz 至 1 MHz","range":"100 nF","cmc":"0,85 %"},{"name":"20 Hz 至 100 Hz","range":"1 µF","cmc":"0,050 %"},{"name":"100 Hz","range":"1 µF","cmc":"0,035 %"},{"name":"100 Hz 至 1 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"1 kHz 至 10 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"10 kHz 至 100 kHz","range":"1 µF","cmc":"0,090 %"},{"name":"20 Hz 至 1 kHz","range":"10 µF","cmc":"0,15 %"},{"name":"1 kHz 至 10 kHz","range":"10 µF","cmc":"0,20 %"},{"name":"20 Hz 至 100 Hz","range":"100 µF","cmc":"0,15 %"},{"name":"100 Hz 至 1 kHz","range":"100 µF","cmc":"0,20 %"},{"name":"1 kHz 至 10 kHz","range":"100 µF","cmc":"0,40 %"}],"parameters_cs":[{"name":"50 Hz až 1 kHz","range":"10 pF","cmc":"0,15 %"},{"name":"1 kHz","range":"10 pF","cmc":"0,075 %"},{"name":"1 kHz až 10 kHz","range":"10 pF","cmc":"0,080 %"},{"name":"10 kHz","range":"10 pF","cmc":"0,040 %"},{"name":"10 kHz až 100 kHz","range":"10 pF","cmc":"0,050 %"},{"name":"100kHz až 1 MHz","range":"10 pF","cmc":"0,15 %"},{"name":"50 Hz až 100 Hz","range":"100 pF","cmc":"0,080 %"},{"name":"100 Hz","range":"100 pF","cmc":"0,050 %"},{"name":"100 Hz až 1 kHz","range":"100 pF","cmc":"0,060 %"},{"name":"1 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"1 kHz až 10 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 pF","cmc":"0,035 %"},{"name":"10 kHz až 100 kHz","range":"100 pF","cmc":"0,050 %"},{"name":"100 kHz","range":"100 pF","cmc":"0,040 %"},{"name":"100 kHz až 1 MHz","range":"100 pF","cmc":"0,15 %"},{"name":"50 Hz až 100 Hz","range":"1 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"1 nF","cmc":"0,035 %"},{"name":"100 Hz až 1 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"1 kHz až 10 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 nF","cmc":"0,030 %"},{"name":"10 kHz až 100 kHz","range":"1 nF","cmc":"0,050 %"},{"name":"100 kHz","range":"1 nF","cmc":"0,040 %"},{"name":"100 kHz až 1 MHz","range":"1 nF","cmc":"0,15 %"},{"name":"50 Hz až 100 Hz","range":"10 nF","cmc":"0,050 %"},{"name":"100 Hz","range":"10 nF","cmc":"0,035 %"},{"name":"100 Hz až 1 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"1 kHz až 10 kHz","range":"10 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"10 nF","cmc":"0,035 %"},{"name":"10 kHz až 100 kHz","range":"10 nF","cmc":"0,060 %"},{"name":"100 kHz až 1 MHz","range":"10 nF","cmc":"0,15 %"},{"name":"50 Hz až 100 Hz","range":"100 nF","cmc":"0,040 %"},{"name":"100 Hz","range":"100 nF","cmc":"0,035 %"},{"name":"100 Hz až 1 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"1 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"1 kHz až 10 kHz","range":"100 nF","cmc":"0,040 %"},{"name":"10 kHz","range":"100 nF","cmc":"0,035 %"},{"name":"10 kHz až 100 kHz","range":"100 nF","cmc":"0,060 %"},{"name":"100 kHz až 1 MHz","range":"100 nF","cmc":"0,85 %"},{"name":"20 Hz až 100 Hz","range":"1 µF","cmc":"0,050 %"},{"name":"100 Hz","range":"1 µF","cmc":"0,035 %"},{"name":"100 Hz až 1 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"1 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"1 kHz až 10 kHz","range":"1 µF","cmc":"0,040 %"},{"name":"10 kHz","range":"1 µF","cmc":"0,035 %"},{"name":"10 kHz až 100 kHz","range":"1 µF","cmc":"0,090 %"},{"name":"20 Hz až 1 kHz","range":"10 µF","cmc":"0,15 %"},{"name":"1 kHz až 10 kHz","range":"10 µF","cmc":"0,20 %"},{"name":"20 Hz až 100 Hz","range":"100 µF","cmc":"0,15 %"},{"name":"100 Hz až 1 kHz","range":"100 µF","cmc":"0,20 %"},{"name":"1 kHz až 10 kHz","range":"100 µF","cmc":"0,40 %"}],"technique":"Porównanie metodą substytucji lub pomiar bezpośredni wzorca pojemności","technique_en":"Comparison by substitution or direct measurement of capacitance standard","technique_zh":"替代法比较或直接测量电容标准器","technique_cs":"Porovnání substitucí nebo přímé měření etalonu kapacity","techniques":["Porównanie metodą substytucji lub pomiar bezpośredni wzorca pojemności"],"techniques_en":["Comparison by substitution or direct measurement of capacitance standard"],"techniques_zh":["替代法比较或直接测量电容标准器"],"techniques_cs":["Porovnání substitucí nebo přímé měření etalonu kapacity"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz do 1 kHz 10 pF CMC 0,15 %\n1 kHz 10 pF CMC 0,075 %\n1 kHz do 10 kHz 10 pF CMC 0,080 %\n10 kHz 10 pF CMC 0,040 %\n10 kHz do 100 kHz 10 pF CMC 0,050 %\n100kHz do 1 MHz 10 pF CMC 0,15 %\n50 Hz do 100 Hz 100 pF CMC 0,080 %\n100 Hz 100 pF CMC 0,050 %\n100 Hz do 1 kHz 100 pF CMC 0,060 %\n1 kHz 100 pF CMC 0,035 %\n1 kHz do 10 kHz 100 pF CMC 0,040 %\n10 kHz 100 pF CMC 0,035 %\n10 kHz do 100 kHz 100 pF CMC 0,050 %\n100 kHz 100 pF CMC 0,040 %\n100 kHz do 1 MHz 100 pF CMC 0,15 %\n50 Hz do 100 Hz 1 nF CMC 0,040 %\n100 Hz 1 nF CMC 0,035 %\n100 Hz do 1 kHz 1 nF CMC 0,040 %\n1 kHz 1 nF CMC 0,030 %\n1 kHz do 10 kHz 1 nF CMC 0,040 %\n10 kHz 1 nF CMC 0,030 %\n10 kHz do 100 kHz 1 nF CMC 0,050 %\n100 kHz 1 nF CMC 0,040 %\n100 kHz do 1 MHz 1 nF CMC 0,15 %\n50 Hz do 100 Hz 10 nF CMC 0,050 %\n100 Hz 10 nF CMC 0,035 %\n100 Hz do 1 kHz 10 nF CMC 0,040 %\n1 kHz 10 nF CMC 0,035 %\n1 kHz do 10 kHz 10 nF CMC 0,040 %\n10 kHz 10 nF CMC 0,035 %\n10 kHz do 100 kHz 10 nF CMC 0,060 %\n100 kHz do 1 MHz 10 nF CMC 0,15 %\n50 Hz do 100 Hz 100 nF CMC 0,040 %\n100 Hz 100 nF CMC 0,035 %\n100 Hz do 1 kHz 100 nF CMC 0,040 %\n1 kHz 100 nF CMC 0,035 %\n1 kHz do 10 kHz 100 nF CMC 0,040 %\n10 kHz 100 nF CMC 0,035 %\n10 kHz do 100 kHz 100 nF CMC 0,060 %\n100 kHz do 1 MHz 100 nF CMC 0,85 %\n20 Hz do 100 Hz 1 µF CMC 0,050 %\n100 Hz 1 µF CMC 0,035 %\n100 Hz do 1 kHz 1 µF CMC 0,040 %\n1 kHz 1 µF CMC 0,035 %\n1 kHz do 10 kHz 1 µF CMC 0,040 %\n10 kHz 1 µF CMC 0,035 %\n10 kHz do 100 kHz 1 µF CMC 0,090 %\n20 Hz do 1 kHz 10 µF CMC 0,15 %\n1 kHz do 10 kHz 10 µF CMC 0,20 %\n20 Hz do 100 Hz 100 µF CMC 0,15 %\n100 Hz do 1 kHz 100 µF CMC 0,20 %\n1 kHz do 10 kHz 100 µF CMC 0,40 %\nPorównanie metodą substytucji lub pomiar bezpośredni wzorca pojemności","reference":"MKE-Z2","norm_bases":["MKE-Z2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / wzorce pojemności, mierniki pojemności, mostki RLC Wzorcowanie – wielkości elektryczne Porównanie metodą substytucji lub pomiar bezpośredni wzorca pojemności 50 Hz do 1 kHz 10 pF CMC 0,15 % 1 kHz 10 pF CMC 0,075 % 1 kHz do 10 kHz 10 pF CMC 0,080 % 10 kHz 10 pF CMC 0,040 % 10 kHz do 100 kHz 10 pF CMC 0,050 % 100kHz do 1 MHz 10 pF CMC 0,15 % 50 Hz do 100 Hz 100 pF CMC 0,080 % 100 Hz 100 pF CMC 0,050 % 100 Hz do 1 kHz 100 pF CMC 0,060 % 1 kHz 100 pF CMC 0,035 % 1 kHz do 10 kHz 100 pF CMC 0,040 % 10 kHz 100 pF CMC 0,035 % 10 kHz do 100 kHz 100 pF CMC 0,050 % 100 kHz 100 pF CMC 0,040 % 100 kHz do 1 MHz 100 pF CMC 0,15 % 50 Hz do 100 Hz 1 nF CMC 0,040 % 100 Hz 1 nF CMC 0,035 % 100 Hz do 1 kHz 1 nF CMC 0,040 % 1 kHz 1 nF CMC 0,030 % 1 kHz do 10 kHz 1 nF CMC 0,040 % 10 kHz 1 nF CMC 0,030 % 10 kHz do 100 kHz 1 nF CMC 0,050 % 100 kHz 1 nF CMC 0,040 % 100 kHz do 1 MHz 1 nF CMC 0,15 % 50 Hz do 100 Hz 10 nF CMC 0,050 % 100 Hz 10 nF CMC 0,035 % 100 Hz do 1 kHz 10 nF CMC 0,040 % 1 kHz 10 nF CMC 0,035 % 1 kHz do 10 kHz 10 nF CMC 0,040 % 10 kHz 10 nF CMC 0,035 % 10 kHz do 100 kHz 10 nF CMC 0,060 % 100 kHz do 1 MHz 10 nF CMC 0,15 % 50 Hz do 100 Hz 100 nF CMC 0,040 % 100 Hz 100 nF CMC 0,035 % 100 Hz do 1 kHz 100 nF CMC 0,040 % 1 kHz 100 nF CMC 0,035 % 1 kHz do 10 kHz 100 nF CMC 0,040 % 10 kHz 100 nF CMC 0,035 % 10 kHz do 100 kHz 100 nF CMC 0,060 % 100 kHz do 1 MHz 100 nF CMC 0,85 % 20 Hz do 100 Hz 1 µF CMC 0,050 % 100 Hz 1 µF CMC 0,035 % 100 Hz do 1 kHz 1 µF CMC 0,040 % 1 kHz 1 µF CMC 0,035 % 1 kHz do 10 kHz 1 µF CMC 0,040 % 10 kHz 1 µF CMC 0,035 % 10 kHz do 100 kHz 1 µF CMC 0,090 % 20 Hz do 1 kHz 10 µF CMC 0,15 % 1 kHz do 10 kHz 10 µF CMC 0,20 % 20 Hz do 100 Hz 100 µF CMC 0,15 % 100 Hz do 1 kHz 100 µF CMC 0,20 % 1 kHz do 10 kHz 100 µF CMC 0,40 % Kapacita / Etalony kapacity, měřidla kapacity, RLC mosty, Kalibrace – elektrické veličiny Porovnání substitucí nebo přímé měření etalonu kapacity 50 Hz až 1 kHz 10 pF CMC 0,15 % 1 kHz 10 pF CMC 0,075 % 1 kHz až 10 kHz 10 pF CMC 0,080 % 10 kHz 10 pF CMC 0,040 % 10 kHz až 100 kHz 10 pF CMC 0,050 % 100kHz až 1 MHz 10 pF CMC 0,15 % 50 Hz až 100 Hz 100 pF CMC 0,080 % 100 Hz 100 pF CMC 0,050 % 100 Hz až 1 kHz 100 pF CMC 0,060 % 1 kHz 100 pF CMC 0,035 % 1 kHz až 10 kHz 100 pF CMC 0,040 % 10 kHz 100 pF CMC 0,035 % 10 kHz až 100 kHz 100 pF CMC 0,050 % 100 kHz 100 pF CMC 0,040 % 100 kHz až 1 MHz 100 pF CMC 0,15 % 50 Hz až 100 Hz 1 nF CMC 0,040 % 100 Hz 1 nF CMC 0,035 % 100 Hz až 1 kHz 1 nF CMC 0,040 % 1 kHz 1 nF CMC 0,030 % 1 kHz až 10 kHz 1 nF CMC 0,040 % 10 kHz 1 nF CMC 0,030 % 10 kHz až 100 kHz 1 nF CMC 0,050 % 100 kHz 1 nF CMC 0,040 % 100 kHz až 1 MHz 1 nF CMC 0,15 % 50 Hz až 100 Hz 10 nF CMC 0,050 % 100 Hz 10 nF CMC 0,035 % 100 Hz až 1 kHz 10 nF CMC 0,040 % 1 kHz 10 nF CMC 0,035 % 1 kHz až 10 kHz 10 nF CMC 0,040 % 10 kHz 10 nF CMC 0,035 % 10 kHz až 100 kHz 10 nF CMC 0,060 % 100 kHz až 1 MHz 10 nF CMC 0,15 % 50 Hz až 100 Hz 100 nF CMC 0,040 % 100 Hz 100 nF CMC 0,035 % 100 Hz až 1 kHz 100 nF CMC 0,040 % 1 kHz 100 nF CMC 0,035 % 1 kHz až 10 kHz 100 nF CMC 0,040 % 10 kHz 100 nF CMC 0,035 % 10 kHz až 100 kHz 100 nF CMC 0,060 % 100 kHz až 1 MHz 100 nF CMC 0,85 % 20 Hz až 100 Hz 1 µF CMC 0,050 % 100 Hz 1 µF CMC 0,035 % 100 Hz až 1 kHz 1 µF CMC 0,040 % 1 kHz 1 µF CMC 0,035 % 1 kHz až 10 kHz 1 µF CMC 0,040 % 10 kHz 1 µF CMC 0,035 % 10 kHz až 100 kHz 1 µF CMC 0,090 % 20 Hz až 1 kHz 10 µF CMC 0,15 % 1 kHz až 10 kHz 10 µF CMC 0,20 % 20 Hz až 100 Hz 100 µF CMC 0,15 % 100 Hz až 1 kHz 100 µF CMC 0,20 % 1 kHz až 10 kHz 100 µF CMC 0,40 % MKE-Z2 Pojemnosc / wzorce pojemnosci, mierniki pojemnosci, mostki RLC Wzorcowanie – wielkosci elektryczne Porownanie metoda substytucji lub pomiar bezposredni wzorca pojemnosci 50 Hz do 1 kHz 10 pF CMC 0,15 % 1 kHz 10 pF CMC 0,075 % 1 kHz do 10 kHz 10 pF CMC 0,080 % 10 kHz 10 pF CMC 0,040 % 10 kHz do 100 kHz 10 pF CMC 0,050 % 100kHz do 1 MHz 10 pF CMC 0,15 % 50 Hz do 100 Hz 100 pF CMC 0,080 % 100 Hz 100 pF CMC 0,050 % 100 Hz do 1 kHz 100 pF CMC 0,060 % 1 kHz 100 pF CMC 0,035 % 1 kHz do 10 kHz 100 pF CMC 0,040 % 10 kHz 100 pF CMC 0,035 % 10 kHz do 100 kHz 100 pF CMC 0,050 % 100 kHz 100 pF CMC 0,040 % 100 kHz do 1 MHz 100 pF CMC 0,15 % 50 Hz do 100 Hz 1 nF CMC 0,040 % 100 Hz 1 nF CMC 0,035 % 100 Hz do 1 kHz 1 nF CMC 0,040 % 1 kHz 1 nF CMC 0,030 % 1 kHz do 10 kHz 1 nF CMC 0,040 % 10 kHz 1 nF CMC 0,030 % 10 kHz do 100 kHz 1 nF CMC 0,050 % 100 kHz 1 nF CMC 0,040 % 100 kHz do 1 MHz 1 nF CMC 0,15 % 50 Hz do 100 Hz 10 nF CMC 0,050 % 100 Hz 10 nF CMC 0,035 % 100 Hz do 1 kHz 10 nF CMC 0,040 % 1 kHz 10 nF CMC 0,035 % 1 kHz do 10 kHz 10 nF CMC 0,040 % 10 kHz 10 nF CMC 0,035 % 10 kHz do 100 kHz 10 nF CMC 0,060 % 100 kHz do 1 MHz 10 nF CMC 0,15 % 50 Hz do 100 Hz 100 nF CMC 0,040 % 100 Hz 100 nF CMC 0,035 % 100 Hz do 1 kHz 100 nF CMC 0,040 % 1 kHz 100 nF CMC 0,035 % 1 kHz do 10 kHz 100 nF CMC 0,040 % 10 kHz 100 nF CMC 0,035 % 10 kHz do 100 kHz 100 nF CMC 0,060 % 100 kHz do 1 MHz 100 nF CMC 0,85 % 20 Hz do 100 Hz 1 µF CMC 0,050 % 100 Hz 1 µF CMC 0,035 % 100 Hz do 1 kHz 1 µF CMC 0,040 % 1 kHz 1 µF CMC 0,035 % 1 kHz do 10 kHz 1 µF CMC 0,040 % 10 kHz 1 µF CMC 0,035 % 10 kHz do 100 kHz 1 µF CMC 0,090 % 20 Hz do 1 kHz 10 µF CMC 0,15 % 1 kHz do 10 kHz 10 µF CMC 0,20 % 20 Hz do 100 Hz 100 µF CMC 0,15 % 100 Hz do 1 kHz 100 µF CMC 0,20 % 1 kHz do 10 kHz 100 µF CMC 0,40 % Kapacita / Etalony kapacity, meridla kapacity, RLC mosty, Kalibrace – elektricke veliciny Porovnani substituci nebo prime mereni etalonu kapacity 50 Hz az 1 kHz 10 pF CMC 0,15 % 1 kHz 10 pF CMC 0,075 % 1 kHz az 10 kHz 10 pF CMC 0,080 % 10 kHz 10 pF CMC 0,040 % 10 kHz az 100 kHz 10 pF CMC 0,050 % 100kHz az 1 MHz 10 pF CMC 0,15 % 50 Hz az 100 Hz 100 pF CMC 0,080 % 100 Hz 100 pF CMC 0,050 % 100 Hz az 1 kHz 100 pF CMC 0,060 % 1 kHz 100 pF CMC 0,035 % 1 kHz az 10 kHz 100 pF CMC 0,040 % 10 kHz 100 pF CMC 0,035 % 10 kHz az 100 kHz 100 pF CMC 0,050 % 100 kHz 100 pF CMC 0,040 % 100 kHz az 1 MHz 100 pF CMC 0,15 % 50 Hz az 100 Hz 1 nF CMC 0,040 % 100 Hz 1 nF CMC 0,035 % 100 Hz az 1 kHz 1 nF CMC 0,040 % 1 kHz 1 nF CMC 0,030 % 1 kHz az 10 kHz 1 nF CMC 0,040 % 10 kHz 1 nF CMC 0,030 % 10 kHz az 100 kHz 1 nF CMC 0,050 % 100 kHz 1 nF CMC 0,040 % 100 kHz az 1 MHz 1 nF CMC 0,15 % 50 Hz az 100 Hz 10 nF CMC 0,050 % 100 Hz 10 nF CMC 0,035 % 100 Hz az 1 kHz 10 nF CMC 0,040 % 1 kHz 10 nF CMC 0,035 % 1 kHz az 10 kHz 10 nF CMC 0,040 % 10 kHz 10 nF CMC 0,035 % 10 kHz az 100 kHz 10 nF CMC 0,060 % 100 kHz az 1 MHz 10 nF CMC 0,15 % 50 Hz az 100 Hz 100 nF CMC 0,040 % 100 Hz 100 nF CMC 0,035 % 100 Hz az 1 kHz 100 nF CMC 0,040 % 1 kHz 100 nF CMC 0,035 % 1 kHz az 10 kHz 100 nF CMC 0,040 % 10 kHz 100 nF CMC 0,035 % 10 kHz az 100 kHz 100 nF CMC 0,060 % 100 kHz az 1 MHz 100 nF CMC 0,85 % 20 Hz az 100 Hz 1 µF CMC 0,050 % 100 Hz 1 µF CMC 0,035 % 100 Hz az 1 kHz 1 µF CMC 0,040 % 1 kHz 1 µF CMC 0,035 % 1 kHz az 10 kHz 1 µF CMC 0,040 % 10 kHz 1 µF CMC 0,035 % 10 kHz az 100 kHz 1 µF CMC 0,090 % 20 Hz az 1 kHz 10 µF CMC 0,15 % 1 kHz az 10 kHz 10 µF CMC 0,20 % 20 Hz az 100 Hz 100 µF CMC 0,15 % 100 Hz az 1 kHz 100 µF CMC 0,20 % 1 kHz az 10 kHz 100 µF CMC 0,40 % MKE-Z2","search_en":"Capacitance / Capacitance standards, capacitance meters, RLC bridges Calibration – electrical quantities Comparison by substitution or direct measurement of capacitance standard 50 Hz to 1 kHz 10 pF CMC 0,15 % 1 kHz 10 pF CMC 0,075 % 1 kHz to 10 kHz 10 pF CMC 0,080 % 10 kHz 10 pF CMC 0,040 % 10 kHz to 100 kHz 10 pF CMC 0,050 % 100kHz to 1 MHz 10 pF CMC 0,15 % 50 Hz to 100 Hz 100 pF CMC 0,080 % 100 Hz 100 pF CMC 0,050 % 100 Hz to 1 kHz 100 pF CMC 0,060 % 1 kHz 100 pF CMC 0,035 % 1 kHz to 10 kHz 100 pF CMC 0,040 % 10 kHz 100 pF CMC 0,035 % 10 kHz to 100 kHz 100 pF CMC 0,050 % 100 kHz 100 pF CMC 0,040 % 100 kHz to 1 MHz 100 pF CMC 0,15 % 50 Hz to 100 Hz 1 nF CMC 0,040 % 100 Hz 1 nF CMC 0,035 % 100 Hz to 1 kHz 1 nF CMC 0,040 % 1 kHz 1 nF CMC 0,030 % 1 kHz to 10 kHz 1 nF CMC 0,040 % 10 kHz 1 nF CMC 0,030 % 10 kHz to 100 kHz 1 nF CMC 0,050 % 100 kHz 1 nF CMC 0,040 % 100 kHz to 1 MHz 1 nF CMC 0,15 % 50 Hz to 100 Hz 10 nF CMC 0,050 % 100 Hz 10 nF CMC 0,035 % 100 Hz to 1 kHz 10 nF CMC 0,040 % 1 kHz 10 nF CMC 0,035 % 1 kHz to 10 kHz 10 nF CMC 0,040 % 10 kHz 10 nF CMC 0,035 % 10 kHz to 100 kHz 10 nF CMC 0,060 % 100 kHz to 1 MHz 10 nF CMC 0,15 % 50 Hz to 100 Hz 100 nF CMC 0,040 % 100 Hz 100 nF CMC 0,035 % 100 Hz to 1 kHz 100 nF CMC 0,040 % 1 kHz 100 nF CMC 0,035 % 1 kHz to 10 kHz 100 nF CMC 0,040 % 10 kHz 100 nF CMC 0,035 % 10 kHz to 100 kHz 100 nF CMC 0,060 % 100 kHz to 1 MHz 100 nF CMC 0,85 % 20 Hz to 100 Hz 1 µF CMC 0,050 % 100 Hz 1 µF CMC 0,035 % 100 Hz to 1 kHz 1 µF CMC 0,040 % 1 kHz 1 µF CMC 0,035 % 1 kHz to 10 kHz 1 µF CMC 0,040 % 10 kHz 1 µF CMC 0,035 % 10 kHz to 100 kHz 1 µF CMC 0,090 % 20 Hz to 1 kHz 10 µF CMC 0,15 % 1 kHz to 10 kHz 10 µF CMC 0,20 % 20 Hz to 100 Hz 100 µF CMC 0,15 % 100 Hz to 1 kHz 100 µF CMC 0,20 % 1 kHz to 10 kHz 100 µF CMC 0,40 % MKE-Z2","search_zh":"电容 / 电容标准器、电容测量仪、RLC 电桥 校准 – 电学量 替代法比较或直接测量电容标准器 50 Hz 至 1 kHz 10 pF CMC 0,15 % 1 kHz 10 pF CMC 0,075 % 1 kHz 至 10 kHz 10 pF CMC 0,080 % 10 kHz 10 pF CMC 0,040 % 10 kHz 至 100 kHz 10 pF CMC 0,050 % 100kHz 至 1 MHz 10 pF CMC 0,15 % 50 Hz 至 100 Hz 100 pF CMC 0,080 % 100 Hz 100 pF CMC 0,050 % 100 Hz 至 1 kHz 100 pF CMC 0,060 % 1 kHz 100 pF CMC 0,035 % 1 kHz 至 10 kHz 100 pF CMC 0,040 % 10 kHz 100 pF CMC 0,035 % 10 kHz 至 100 kHz 100 pF CMC 0,050 % 100 kHz 100 pF CMC 0,040 % 100 kHz 至 1 MHz 100 pF CMC 0,15 % 50 Hz 至 100 Hz 1 nF CMC 0,040 % 100 Hz 1 nF CMC 0,035 % 100 Hz 至 1 kHz 1 nF CMC 0,040 % 1 kHz 1 nF CMC 0,030 % 1 kHz 至 10 kHz 1 nF CMC 0,040 % 10 kHz 1 nF CMC 0,030 % 10 kHz 至 100 kHz 1 nF CMC 0,050 % 100 kHz 1 nF CMC 0,040 % 100 kHz 至 1 MHz 1 nF CMC 0,15 % 50 Hz 至 100 Hz 10 nF CMC 0,050 % 100 Hz 10 nF CMC 0,035 % 100 Hz 至 1 kHz 10 nF CMC 0,040 % 1 kHz 10 nF CMC 0,035 % 1 kHz 至 10 kHz 10 nF CMC 0,040 % 10 kHz 10 nF CMC 0,035 % 10 kHz 至 100 kHz 10 nF CMC 0,060 % 100 kHz 至 1 MHz 10 nF CMC 0,15 % 50 Hz 至 100 Hz 100 nF CMC 0,040 % 100 Hz 100 nF CMC 0,035 % 100 Hz 至 1 kHz 100 nF CMC 0,040 % 1 kHz 100 nF CMC 0,035 % 1 kHz 至 10 kHz 100 nF CMC 0,040 % 10 kHz 100 nF CMC 0,035 % 10 kHz 至 100 kHz 100 nF CMC 0,060 % 100 kHz 至 1 MHz 100 nF CMC 0,85 % 20 Hz 至 100 Hz 1 µF CMC 0,050 % 100 Hz 1 µF CMC 0,035 % 100 Hz 至 1 kHz 1 µF CMC 0,040 % 1 kHz 1 µF CMC 0,035 % 1 kHz 至 10 kHz 1 µF CMC 0,040 % 10 kHz 1 µF CMC 0,035 % 10 kHz 至 100 kHz 1 µF CMC 0,090 % 20 Hz 至 1 kHz 10 µF CMC 0,15 % 1 kHz 至 10 kHz 10 µF CMC 0,20 % 20 Hz 至 100 Hz 100 µF CMC 0,15 % 100 Hz 至 1 kHz 100 µF CMC 0,20 % 1 kHz 至 10 kHz 100 µF CMC 0,40 % MKE-Z2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"920182c3f1be21eecfcb0594","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"17","test_object":"Pojemność / wzorce, dekady, mierniki pojemności, mostki RLC","test_object_en":"Capacitance / Standards, boxes, capacitance meters, RLC bridges","test_object_zh":"电容 / 标准器、电容箱、电容测量仪、RLC 电桥","test_object_cs":"Kapacita / Etalony, dekády, měřidla kapacity, RLC mosty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz do 2 kHz","range":"od 1 pF do 10 pF","cmc":"0,10 % + 0,135 pF"},{"name":"2 kHz do 5 kHz","range":"od 1 pF do 10 pF","cmc":"0,10 % + 0,062 pF"},{"name":"5 kHz do 10 kHz","range":"od 1 pF do 10 pF","cmc":"0,10 % + 0,023 pF"},{"name":"10 kHz do 20 kHz","range":"od 1 pF do 10 pF","cmc":"0,17 % + 0,011 pF"},{"name":"20 kHz do 50 kHz","range":"od 1 pF do 10 pF","cmc":"0,22 % + 0,002 pF"},{"name":"50 kHz do 100 kHz","range":"od 1 pF do 10 pF","cmc":"0,28 % + 0,010 pF"},{"name":"100 kHz do 500 kHz","range":"od 1 pF do 10 pF","cmc":"0,40 % + 0,005 pF"},{"name":"500 kHz do 1 MHz","range":"od 1 pF do 10 pF","cmc":"0,55 % + 0,002 pF"},{"name":"500 Hz do 1 kHz","range":"od 10 pF do 100 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz do 2 kHz","range":"od 10 pF do 100 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz do 5 kHz","range":"od 10 pF do 100 pF","cmc":"0,10 % + 0,07 pF"},{"name":"5 kHz do 10 kHz","range":"od 10 pF do 100 pF","cmc":"0,10 % + 0,03 pF"},{"name":"10 kHz do 50 kHz","range":"od 10 pF do 100 pF","cmc":"0,15 % + 0,015 pF"},{"name":"50 kHz do 500 kHz","range":"od 10 pF do 100 pF","cmc":"0,15 % + 0,030 pF"},{"name":"500 kHz do 1 MHz","range":"od 10 pF do 100 pF","cmc":"0,40 % + 0,020 pF"},{"name":"100 Hz do 200 Hz","range":"od 100 pF do 1000 pF","cmc":"0,10 % + 2 pF"},{"name":"200 Hz do 500 Hz","range":"od 100 pF do 1000 pF","cmc":"0,10 % + 0,85 pF"},{"name":"500 Hz do 1 kHz","range":"od 100 pF do 1000 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz do 2 kHz","range":"od 100 pF do 1000 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz do 500 kHz","range":"od 100 pF do 1000 pF","cmc":"0,15 %"},{"name":"500 kHz do 1 MH","range":"od 100 pF do 1000 pF","cmc":"0,35 %"},{"name":"50 Hz do 100 Hz","range":"od 1 nF do 10 nF","cmc":"0,15 % + 0,005 nF"},{"name":"100 Hz do 500 Hz","range":"od 1 nF do 10 nF","cmc":"0,10 % + 0,002 pF"},{"name":"500 Hz do 5 kHz","range":"od 1 nF do 10 nF","cmc":"0,10 %"},{"name":"5 kHz do 100 kHz","range":"od 1 nF do 10 nF","cmc":"0,12 %"},{"name":"100 kHz do 200 kHz","range":"od 1 nF do 10 nF","cmc":"0,13 %"},{"name":"200 kHz do 500 kHz","range":"od 1 nF do 10 nF","cmc":"0,15 %"},{"name":"500 kHz do 1 MHz","range":"od 1 nF do 10 nF","cmc":"0,50 %"},{"name":"50 Hz do 100 Hz","range":"od 10 nF do 100 nF","cmc":"0,20 %"},{"name":"100 Hz do 5 kHz","range":"od 10 nF do 100 nF","cmc":"0,10 %"},{"name":"5 kHz do 50 kHz","range":"od 10 nF do 100 nF","cmc":"0,12 %"},{"name":"50 kHz do 200 kHz","range":"od 10 nF do 100 nF","cmc":"0,20 %"},{"name":"200 kHz do 500 kHz","range":"od 10 nF do 100 nF","cmc":"0,25 %"},{"name":"500 kHz do 1 MHz","range":"od 10 nF do 100 nF","cmc":"0,55 %"},{"name":"50 Hz do 100 Hz","range":"od 100 nF do 1000 nF","cmc":"0,17 %"},{"name":"100 Hz do 500 Hz","range":"od 100 nF do 1000 nF","cmc":"0,10 %"},{"name":"500 Hz do 5 kHz","range":"od 100 nF do 1000 nF","cmc":"0,12 %"},{"name":"5 kHz do 50 kHz","range":"od 100 nF do 1000 nF","cmc":"0,20 %"},{"name":"50 kHz do 100 kHz","range":"od 100 nF do 1000 nF","cmc":"0,25 %"},{"name":"100 kHz do 200 kHz","range":"od 100 nF do 1000 nF","cmc":"0,30 %"},{"name":"200 kHz do 1 MHz","range":"od 100 nF do 1000 nF","cmc":"0,45 %"},{"name":"20 Hz do 100 Hz","range":"od 1 µF do 10 µF","cmc":"0,16 %"},{"name":"100 Hz do 500 Hz","range":"od 1 µF do 10 µF","cmc":"0,10 %"},{"name":"500 Hz do 2 kHz","range":"od 1 µF do 10 µF","cmc":"0,20 %"},{"name":"2 kHz do 5 kHz","range":"od 1 µF do 10 µF","cmc":"0,22 %"},{"name":"5 kHz do 10 kHz","range":"od 1 µF do 10 µF","cmc":"0,25 %"},{"name":"10 kHz do 20 kHz","range":"od 1 µF do 10 µF","cmc":"0,30 %"},{"name":"20 kHz do 100 kHz","range":"od 1 µF do 10 µF","cmc":"(C/40 + 0,20) %"},{"name":"20 Hz do 50 Hz","range":"od 10 µF do 100 µF","cmc":"0,17 %"},{"name":"50 Hz do 200 Hz","range":"od 10 µF do 100 µF","cmc":"0,20 %"},{"name":"200 Hz do 500 Hz","range":"od 10 µF do 100 µF","cmc":"0,25 %"},{"name":"500 Hz do 1 kHz","range":"od 10 µF do 100 µF","cmc":"0,30 %"},{"name":"1 kHz do 2 kHz","range":"od 10 µF do 100 µF","cmc":"0,35 %"},{"name":"2 kHz do 5 kHz","range":"od 10 µF do 100 µF","cmc":"(C/500 + 0,25) %"},{"name":"5 kHz do 10 kHz","range":"od 10 µF do 100 µF","cmc":"(C/250 + 0,25) %"},{"name":"10 kHz do 20 kHz","range":"od 10 µF do 100 µF","cmc":"(C/120 + 0,25) %"},{"name":"20 Hz do 200 Hz","range":"od 100 µF do 1000 µF","cmc":"(C/3500 + 0,15) %"},{"name":"200 Hz do 500 Hz","range":"od 100 µF do 1000 µF","cmc":"(C/2800 + 0,20) %"},{"name":"500 Hz do 1 kHz","range":"od 100 µF do 1000 µF","cmc":"(C/1900 + 0,30) %"},{"name":"1 kHz do 2 kHz","range":"od 100 µF do 1000 µF","cmc":"(C/1000 + 0,30) %"},{"name":"2 kHz do 5 kHz","range":"od 100 µF do 1000 µF","cmc":"(C/500 + 0,30) %"},{"name":"20 Hz do 50 Hz","range":"od 1000 µF do 10000 µF","cmc":"(C/12000 + 0,30) %"},{"name":"50 Hz do 100 Hz","range":"od 1000 µF do 10000 µF","cmc":"(C/9000 + 0,30) %"},{"name":"100 Hz do 200 Hz","range":"od 1000 µF do 10000 µF","cmc":"(C/5000 + 0,20) %"}],"parameters_en":[{"name":"1 kHz to 2 kHz","range":"1 pF to 10 pF","cmc":"0,10 % + 0,135 pF"},{"name":"2 kHz to 5 kHz","range":"1 pF to 10 pF","cmc":"0,10 % + 0,062 pF"},{"name":"5 kHz to 10 kHz","range":"1 pF to 10 pF","cmc":"0,10 % + 0,023 pF"},{"name":"10 kHz to 20 kHz","range":"1 pF to 10 pF","cmc":"0,17 % + 0,011 pF"},{"name":"20 kHz to 50 kHz","range":"1 pF to 10 pF","cmc":"0,22 % + 0,002 pF"},{"name":"50 kHz to 100 kHz","range":"1 pF to 10 pF","cmc":"0,28 % + 0,010 pF"},{"name":"100 kHz to 500 kHz","range":"1 pF to 10 pF","cmc":"0,40 % + 0,005 pF"},{"name":"500 kHz to 1 MHz","range":"1 pF to 10 pF","cmc":"0,55 % + 0,002 pF"},{"name":"500 Hz to 1 kHz","range":"10 pF to 100 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz to 2 kHz","range":"10 pF to 100 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz to 5 kHz","range":"10 pF to 100 pF","cmc":"0,10 % + 0,07 pF"},{"name":"5 kHz to 10 kHz","range":"10 pF to 100 pF","cmc":"0,10 % + 0,03 pF"},{"name":"10 kHz to 50 kHz","range":"10 pF to 100 pF","cmc":"0,15 % + 0,015 pF"},{"name":"50 kHz to 500 kHz","range":"10 pF to 100 pF","cmc":"0,15 % + 0,030 pF"},{"name":"500 kHz to 1 MHz","range":"10 pF to 100 pF","cmc":"0,40 % + 0,020 pF"},{"name":"100 Hz to 200 Hz","range":"100 pF to 1000 pF","cmc":"0,10 % + 2 pF"},{"name":"200 Hz to 500 Hz","range":"100 pF to 1000 pF","cmc":"0,10 % + 0,85 pF"},{"name":"500 Hz to 1 kHz","range":"100 pF to 1000 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz to 2 kHz","range":"100 pF to 1000 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz to 500 kHz","range":"100 pF to 1000 pF","cmc":"0,15 %"},{"name":"500 kHz to 1 MH","range":"100 pF to 1000 pF","cmc":"0,35 %"},{"name":"50 Hz to 100 Hz","range":"1 nF to 10 nF","cmc":"0,15 % + 0,005 nF"},{"name":"100 Hz to 500 Hz","range":"1 nF to 10 nF","cmc":"0,10 % + 0,002 pF"},{"name":"500 Hz to 5 kHz","range":"1 nF to 10 nF","cmc":"0,10 %"},{"name":"5 kHz to 100 kHz","range":"1 nF to 10 nF","cmc":"0,12 %"},{"name":"100 kHz to 200 kHz","range":"1 nF to 10 nF","cmc":"0,13 %"},{"name":"200 kHz to 500 kHz","range":"1 nF to 10 nF","cmc":"0,15 %"},{"name":"500 kHz to 1 MHz","range":"1 nF to 10 nF","cmc":"0,50 %"},{"name":"50 Hz to 100 Hz","range":"10 nF to 100 nF","cmc":"0,20 %"},{"name":"100 Hz to 5 kHz","range":"10 nF to 100 nF","cmc":"0,10 %"},{"name":"5 kHz to 50 kHz","range":"10 nF to 100 nF","cmc":"0,12 %"},{"name":"50 kHz to 200 kHz","range":"10 nF to 100 nF","cmc":"0,20 %"},{"name":"200 kHz to 500 kHz","range":"10 nF to 100 nF","cmc":"0,25 %"},{"name":"500 kHz to 1 MHz","range":"10 nF to 100 nF","cmc":"0,55 %"},{"name":"50 Hz to 100 Hz","range":"100 nF to 1000 nF","cmc":"0,17 %"},{"name":"100 Hz to 500 Hz","range":"100 nF to 1000 nF","cmc":"0,10 %"},{"name":"500 Hz to 5 kHz","range":"100 nF to 1000 nF","cmc":"0,12 %"},{"name":"5 kHz to 50 kHz","range":"100 nF to 1000 nF","cmc":"0,20 %"},{"name":"50 kHz to 100 kHz","range":"100 nF to 1000 nF","cmc":"0,25 %"},{"name":"100 kHz to 200 kHz","range":"100 nF to 1000 nF","cmc":"0,30 %"},{"name":"200 kHz to 1 MHz","range":"100 nF to 1000 nF","cmc":"0,45 %"},{"name":"20 Hz to 100 Hz","range":"1 µF to 10 µF","cmc":"0,16 %"},{"name":"100 Hz to 500 Hz","range":"1 µF to 10 µF","cmc":"0,10 %"},{"name":"500 Hz to 2 kHz","range":"1 µF to 10 µF","cmc":"0,20 %"},{"name":"2 kHz to 5 kHz","range":"1 µF to 10 µF","cmc":"0,22 %"},{"name":"5 kHz to 10 kHz","range":"1 µF to 10 µF","cmc":"0,25 %"},{"name":"10 kHz to 20 kHz","range":"1 µF to 10 µF","cmc":"0,30 %"},{"name":"20 kHz to 100 kHz","range":"1 µF to 10 µF","cmc":"(C/40 + 0,20) %"},{"name":"20 Hz to 50 Hz","range":"10 µF to 100 µF","cmc":"0,17 %"},{"name":"50 Hz to 200 Hz","range":"10 µF to 100 µF","cmc":"0,20 %"},{"name":"200 Hz to 500 Hz","range":"10 µF to 100 µF","cmc":"0,25 %"},{"name":"500 Hz to 1 kHz","range":"10 µF to 100 µF","cmc":"0,30 %"},{"name":"1 kHz to 2 kHz","range":"10 µF to 100 µF","cmc":"0,35 %"},{"name":"2 kHz to 5 kHz","range":"10 µF to 100 µF","cmc":"(C/500 + 0,25) %"},{"name":"5 kHz to 10 kHz","range":"10 µF to 100 µF","cmc":"(C/250 + 0,25) %"},{"name":"10 kHz to 20 kHz","range":"10 µF to 100 µF","cmc":"(C/120 + 0,25) %"},{"name":"20 Hz to 200 Hz","range":"100 µF to 1000 µF","cmc":"(C/3500 + 0,15) %"},{"name":"200 Hz to 500 Hz","range":"100 µF to 1000 µF","cmc":"(C/2800 + 0,20) %"},{"name":"500 Hz to 1 kHz","range":"100 µF to 1000 µF","cmc":"(C/1900 + 0,30) %"},{"name":"1 kHz to 2 kHz","range":"100 µF to 1000 µF","cmc":"(C/1000 + 0,30) %"},{"name":"2 kHz to 5 kHz","range":"100 µF to 1000 µF","cmc":"(C/500 + 0,30) %"},{"name":"20 Hz to 50 Hz","range":"1000 µF to 10000 µF","cmc":"(C/12000 + 0,30) %"},{"name":"50 Hz to 100 Hz","range":"1000 µF to 10000 µF","cmc":"(C/9000 + 0,30) %"},{"name":"100 Hz to 200 Hz","range":"1000 µF to 10000 µF","cmc":"(C/5000 + 0,20) %"}],"parameters_zh":[{"name":"1 kHz 至 2 kHz","range":"1 pF 至 10 pF","cmc":"0,10 % + 0,135 pF"},{"name":"2 kHz 至 5 kHz","range":"1 pF 至 10 pF","cmc":"0,10 % + 0,062 pF"},{"name":"5 kHz 至 10 kHz","range":"1 pF 至 10 pF","cmc":"0,10 % + 0,023 pF"},{"name":"10 kHz 至 20 kHz","range":"1 pF 至 10 pF","cmc":"0,17 % + 0,011 pF"},{"name":"20 kHz 至 50 kHz","range":"1 pF 至 10 pF","cmc":"0,22 % + 0,002 pF"},{"name":"50 kHz 至 100 kHz","range":"1 pF 至 10 pF","cmc":"0,28 % + 0,010 pF"},{"name":"100 kHz 至 500 kHz","range":"1 pF 至 10 pF","cmc":"0,40 % + 0,005 pF"},{"name":"500 kHz 至 1 MHz","range":"1 pF 至 10 pF","cmc":"0,55 % + 0,002 pF"},{"name":"500 Hz 至 1 kHz","range":"10 pF 至 100 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz 至 2 kHz","range":"10 pF 至 100 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz 至 5 kHz","range":"10 pF 至 100 pF","cmc":"0,10 % + 0,07 pF"},{"name":"5 kHz 至 10 kHz","range":"10 pF 至 100 pF","cmc":"0,10 % + 0,03 pF"},{"name":"10 kHz 至 50 kHz","range":"10 pF 至 100 pF","cmc":"0,15 % + 0,015 pF"},{"name":"50 kHz 至 500 kHz","range":"10 pF 至 100 pF","cmc":"0,15 % + 0,030 pF"},{"name":"500 kHz 至 1 MHz","range":"10 pF 至 100 pF","cmc":"0,40 % + 0,020 pF"},{"name":"100 Hz 至 200 Hz","range":"100 pF 至 1000 pF","cmc":"0,10 % + 2 pF"},{"name":"200 Hz 至 500 Hz","range":"100 pF 至 1000 pF","cmc":"0,10 % + 0,85 pF"},{"name":"500 Hz 至 1 kHz","range":"100 pF 至 1000 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz 至 2 kHz","range":"100 pF 至 1000 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz 至 500 kHz","range":"100 pF 至 1000 pF","cmc":"0,15 %"},{"name":"500 kHz 至 1 MH","range":"100 pF 至 1000 pF","cmc":"0,35 %"},{"name":"50 Hz 至 100 Hz","range":"1 nF 至 10 nF","cmc":"0,15 % + 0,005 nF"},{"name":"100 Hz 至 500 Hz","range":"1 nF 至 10 nF","cmc":"0,10 % + 0,002 pF"},{"name":"500 Hz 至 5 kHz","range":"1 nF 至 10 nF","cmc":"0,10 %"},{"name":"5 kHz 至 100 kHz","range":"1 nF 至 10 nF","cmc":"0,12 %"},{"name":"100 kHz 至 200 kHz","range":"1 nF 至 10 nF","cmc":"0,13 %"},{"name":"200 kHz 至 500 kHz","range":"1 nF 至 10 nF","cmc":"0,15 %"},{"name":"500 kHz 至 1 MHz","range":"1 nF 至 10 nF","cmc":"0,50 %"},{"name":"50 Hz 至 100 Hz","range":"10 nF 至 100 nF","cmc":"0,20 %"},{"name":"100 Hz 至 5 kHz","range":"10 nF 至 100 nF","cmc":"0,10 %"},{"name":"5 kHz 至 50 kHz","range":"10 nF 至 100 nF","cmc":"0,12 %"},{"name":"50 kHz 至 200 kHz","range":"10 nF 至 100 nF","cmc":"0,20 %"},{"name":"200 kHz 至 500 kHz","range":"10 nF 至 100 nF","cmc":"0,25 %"},{"name":"500 kHz 至 1 MHz","range":"10 nF 至 100 nF","cmc":"0,55 %"},{"name":"50 Hz 至 100 Hz","range":"100 nF 至 1000 nF","cmc":"0,17 %"},{"name":"100 Hz 至 500 Hz","range":"100 nF 至 1000 nF","cmc":"0,10 %"},{"name":"500 Hz 至 5 kHz","range":"100 nF 至 1000 nF","cmc":"0,12 %"},{"name":"5 kHz 至 50 kHz","range":"100 nF 至 1000 nF","cmc":"0,20 %"},{"name":"50 kHz 至 100 kHz","range":"100 nF 至 1000 nF","cmc":"0,25 %"},{"name":"100 kHz 至 200 kHz","range":"100 nF 至 1000 nF","cmc":"0,30 %"},{"name":"200 kHz 至 1 MHz","range":"100 nF 至 1000 nF","cmc":"0,45 %"},{"name":"20 Hz 至 100 Hz","range":"1 µF 至 10 µF","cmc":"0,16 %"},{"name":"100 Hz 至 500 Hz","range":"1 µF 至 10 µF","cmc":"0,10 %"},{"name":"500 Hz 至 2 kHz","range":"1 µF 至 10 µF","cmc":"0,20 %"},{"name":"2 kHz 至 5 kHz","range":"1 µF 至 10 µF","cmc":"0,22 %"},{"name":"5 kHz 至 10 kHz","range":"1 µF 至 10 µF","cmc":"0,25 %"},{"name":"10 kHz 至 20 kHz","range":"1 µF 至 10 µF","cmc":"0,30 %"},{"name":"20 kHz 至 100 kHz","range":"1 µF 至 10 µF","cmc":"(C/40 + 0,20) %"},{"name":"20 Hz 至 50 Hz","range":"10 µF 至 100 µF","cmc":"0,17 %"},{"name":"50 Hz 至 200 Hz","range":"10 µF 至 100 µF","cmc":"0,20 %"},{"name":"200 Hz 至 500 Hz","range":"10 µF 至 100 µF","cmc":"0,25 %"},{"name":"500 Hz 至 1 kHz","range":"10 µF 至 100 µF","cmc":"0,30 %"},{"name":"1 kHz 至 2 kHz","range":"10 µF 至 100 µF","cmc":"0,35 %"},{"name":"2 kHz 至 5 kHz","range":"10 µF 至 100 µF","cmc":"(C/500 + 0,25) %"},{"name":"5 kHz 至 10 kHz","range":"10 µF 至 100 µF","cmc":"(C/250 + 0,25) %"},{"name":"10 kHz 至 20 kHz","range":"10 µF 至 100 µF","cmc":"(C/120 + 0,25) %"},{"name":"20 Hz 至 200 Hz","range":"100 µF 至 1000 µF","cmc":"(C/3500 + 0,15) %"},{"name":"200 Hz 至 500 Hz","range":"100 µF 至 1000 µF","cmc":"(C/2800 + 0,20) %"},{"name":"500 Hz 至 1 kHz","range":"100 µF 至 1000 µF","cmc":"(C/1900 + 0,30) %"},{"name":"1 kHz 至 2 kHz","range":"100 µF 至 1000 µF","cmc":"(C/1000 + 0,30) %"},{"name":"2 kHz 至 5 kHz","range":"100 µF 至 1000 µF","cmc":"(C/500 + 0,30) %"},{"name":"20 Hz 至 50 Hz","range":"1000 µF 至 10000 µF","cmc":"(C/12000 + 0,30) %"},{"name":"50 Hz 至 100 Hz","range":"1000 µF 至 10000 µF","cmc":"(C/9000 + 0,30) %"},{"name":"100 Hz 至 200 Hz","range":"1000 µF 至 10000 µF","cmc":"(C/5000 + 0,20) %"}],"parameters_cs":[{"name":"1 kHz až 2 kHz","range":"1 pF až 10 pF","cmc":"0,10 % + 0,135 pF"},{"name":"2 kHz až 5 kHz","range":"1 pF až 10 pF","cmc":"0,10 % + 0,062 pF"},{"name":"5 kHz až 10 kHz","range":"1 pF až 10 pF","cmc":"0,10 % + 0,023 pF"},{"name":"10 kHz až 20 kHz","range":"1 pF až 10 pF","cmc":"0,17 % + 0,011 pF"},{"name":"20 kHz až 50 kHz","range":"1 pF až 10 pF","cmc":"0,22 % + 0,002 pF"},{"name":"50 kHz až 100 kHz","range":"1 pF až 10 pF","cmc":"0,28 % + 0,010 pF"},{"name":"100 kHz až 500 kHz","range":"1 pF až 10 pF","cmc":"0,40 % + 0,005 pF"},{"name":"500 kHz až 1 MHz","range":"1 pF až 10 pF","cmc":"0,55 % + 0,002 pF"},{"name":"500 Hz až 1 kHz","range":"10 pF až 100 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz až 2 kHz","range":"10 pF až 100 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz až 5 kHz","range":"10 pF až 100 pF","cmc":"0,10 % + 0,07 pF"},{"name":"5 kHz až 10 kHz","range":"10 pF až 100 pF","cmc":"0,10 % + 0,03 pF"},{"name":"10 kHz až 50 kHz","range":"10 pF až 100 pF","cmc":"0,15 % + 0,015 pF"},{"name":"50 kHz až 500 kHz","range":"10 pF až 100 pF","cmc":"0,15 % + 0,030 pF"},{"name":"500 kHz až 1 MHz","range":"10 pF až 100 pF","cmc":"0,40 % + 0,020 pF"},{"name":"100 Hz až 200 Hz","range":"100 pF až 1000 pF","cmc":"0,10 % + 2 pF"},{"name":"200 Hz až 500 Hz","range":"100 pF až 1000 pF","cmc":"0,10 % + 0,85 pF"},{"name":"500 Hz až 1 kHz","range":"100 pF až 1000 pF","cmc":"0,10 % + 0,30 pF"},{"name":"1 kHz až 2 kHz","range":"100 pF až 1000 pF","cmc":"0,10 % + 0,15 pF"},{"name":"2 kHz až 500 kHz","range":"100 pF až 1000 pF","cmc":"0,15 %"},{"name":"500 kHz až 1 MH","range":"100 pF až 1000 pF","cmc":"0,35 %"},{"name":"50 Hz až 100 Hz","range":"1 nF až 10 nF","cmc":"0,15 % + 0,005 nF"},{"name":"100 Hz až 500 Hz","range":"1 nF až 10 nF","cmc":"0,10 % + 0,002 pF"},{"name":"500 Hz až 5 kHz","range":"1 nF až 10 nF","cmc":"0,10 %"},{"name":"5 kHz až 100 kHz","range":"1 nF až 10 nF","cmc":"0,12 %"},{"name":"100 kHz až 200 kHz","range":"1 nF až 10 nF","cmc":"0,13 %"},{"name":"200 kHz až 500 kHz","range":"1 nF až 10 nF","cmc":"0,15 %"},{"name":"500 kHz až 1 MHz","range":"1 nF až 10 nF","cmc":"0,50 %"},{"name":"50 Hz až 100 Hz","range":"10 nF až 100 nF","cmc":"0,20 %"},{"name":"100 Hz až 5 kHz","range":"10 nF až 100 nF","cmc":"0,10 %"},{"name":"5 kHz až 50 kHz","range":"10 nF až 100 nF","cmc":"0,12 %"},{"name":"50 kHz až 200 kHz","range":"10 nF až 100 nF","cmc":"0,20 %"},{"name":"200 kHz až 500 kHz","range":"10 nF až 100 nF","cmc":"0,25 %"},{"name":"500 kHz až 1 MHz","range":"10 nF až 100 nF","cmc":"0,55 %"},{"name":"50 Hz až 100 Hz","range":"100 nF až 1000 nF","cmc":"0,17 %"},{"name":"100 Hz až 500 Hz","range":"100 nF až 1000 nF","cmc":"0,10 %"},{"name":"500 Hz až 5 kHz","range":"100 nF až 1000 nF","cmc":"0,12 %"},{"name":"5 kHz až 50 kHz","range":"100 nF až 1000 nF","cmc":"0,20 %"},{"name":"50 kHz až 100 kHz","range":"100 nF až 1000 nF","cmc":"0,25 %"},{"name":"100 kHz až 200 kHz","range":"100 nF až 1000 nF","cmc":"0,30 %"},{"name":"200 kHz až 1 MHz","range":"100 nF až 1000 nF","cmc":"0,45 %"},{"name":"20 Hz až 100 Hz","range":"1 µF až 10 µF","cmc":"0,16 %"},{"name":"100 Hz až 500 Hz","range":"1 µF až 10 µF","cmc":"0,10 %"},{"name":"500 Hz až 2 kHz","range":"1 µF až 10 µF","cmc":"0,20 %"},{"name":"2 kHz až 5 kHz","range":"1 µF až 10 µF","cmc":"0,22 %"},{"name":"5 kHz až 10 kHz","range":"1 µF až 10 µF","cmc":"0,25 %"},{"name":"10 kHz až 20 kHz","range":"1 µF až 10 µF","cmc":"0,30 %"},{"name":"20 kHz až 100 kHz","range":"1 µF až 10 µF","cmc":"(C/40 + 0,20) %"},{"name":"20 Hz až 50 Hz","range":"10 µF až 100 µF","cmc":"0,17 %"},{"name":"50 Hz až 200 Hz","range":"10 µF až 100 µF","cmc":"0,20 %"},{"name":"200 Hz až 500 Hz","range":"10 µF až 100 µF","cmc":"0,25 %"},{"name":"500 Hz až 1 kHz","range":"10 µF až 100 µF","cmc":"0,30 %"},{"name":"1 kHz až 2 kHz","range":"10 µF až 100 µF","cmc":"0,35 %"},{"name":"2 kHz až 5 kHz","range":"10 µF až 100 µF","cmc":"(C/500 + 0,25) %"},{"name":"5 kHz až 10 kHz","range":"10 µF až 100 µF","cmc":"(C/250 + 0,25) %"},{"name":"10 kHz až 20 kHz","range":"10 µF až 100 µF","cmc":"(C/120 + 0,25) %"},{"name":"20 Hz až 200 Hz","range":"100 µF až 1000 µF","cmc":"(C/3500 + 0,15) %"},{"name":"200 Hz až 500 Hz","range":"100 µF až 1000 µF","cmc":"(C/2800 + 0,20) %"},{"name":"500 Hz až 1 kHz","range":"100 µF až 1000 µF","cmc":"(C/1900 + 0,30) %"},{"name":"1 kHz až 2 kHz","range":"100 µF až 1000 µF","cmc":"(C/1000 + 0,30) %"},{"name":"2 kHz až 5 kHz","range":"100 µF až 1000 µF","cmc":"(C/500 + 0,30) %"},{"name":"20 Hz až 50 Hz","range":"1000 µF až 10000 µF","cmc":"(C/12000 + 0,30) %"},{"name":"50 Hz až 100 Hz","range":"1000 µF až 10000 µF","cmc":"(C/9000 + 0,30) %"},{"name":"100 Hz až 200 Hz","range":"1000 µF až 10000 µF","cmc":"(C/5000 + 0,20) %"}],"technique":"Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC","technique_en":"Direct measurement or comparison by substitution with a reference RLC bridge","technique_zh":"直接测量或用标准RLC电桥替代法比较","technique_cs":"Přímé měření nebo porovnání substitucí s etalonovým RLC mostem","techniques":["Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC"],"techniques_en":["Direct measurement or comparison by substitution with a reference RLC bridge"],"techniques_zh":["直接测量或用标准RLC电桥替代法比较"],"techniques_cs":["Přímé měření nebo porovnání substitucí s etalonovým RLC mostem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz do 2 kHz od 1 pF do 10 pF CMC 0,10 % + 0,135 pF\n2 kHz do 5 kHz od 1 pF do 10 pF CMC 0,10 % + 0,062 pF\n5 kHz do 10 kHz od 1 pF do 10 pF CMC 0,10 % + 0,023 pF\n10 kHz do 20 kHz od 1 pF do 10 pF CMC 0,17 % + 0,011 pF\n20 kHz do 50 kHz od 1 pF do 10 pF CMC 0,22 % + 0,002 pF\n50 kHz do 100 kHz od 1 pF do 10 pF CMC 0,28 % + 0,010 pF\n100 kHz do 500 kHz od 1 pF do 10 pF CMC 0,40 % + 0,005 pF\n500 kHz do 1 MHz od 1 pF do 10 pF CMC 0,55 % + 0,002 pF\n500 Hz do 1 kHz od 10 pF do 100 pF CMC 0,10 % + 0,30 pF\n1 kHz do 2 kHz od 10 pF do 100 pF CMC 0,10 % + 0,15 pF\n2 kHz do 5 kHz od 10 pF do 100 pF CMC 0,10 % + 0,07 pF\n5 kHz do 10 kHz od 10 pF do 100 pF CMC 0,10 % + 0,03 pF\n10 kHz do 50 kHz od 10 pF do 100 pF CMC 0,15 % + 0,015 pF\n50 kHz do 500 kHz od 10 pF do 100 pF CMC 0,15 % + 0,030 pF\n500 kHz do 1 MHz od 10 pF do 100 pF CMC 0,40 % + 0,020 pF\n100 Hz do 200 Hz od 100 pF do 1000 pF CMC 0,10 % + 2 pF\n200 Hz do 500 Hz od 100 pF do 1000 pF CMC 0,10 % + 0,85 pF\n500 Hz do 1 kHz od 100 pF do 1000 pF CMC 0,10 % + 0,30 pF\n1 kHz do 2 kHz od 100 pF do 1000 pF CMC 0,10 % + 0,15 pF\n2 kHz do 500 kHz od 100 pF do 1000 pF CMC 0,15 %\n500 kHz do 1 MH od 100 pF do 1000 pF CMC 0,35 %\n50 Hz do 100 Hz od 1 nF do 10 nF CMC 0,15 % + 0,005 nF\n100 Hz do 500 Hz od 1 nF do 10 nF CMC 0,10 % + 0,002 pF\n500 Hz do 5 kHz od 1 nF do 10 nF CMC 0,10 %\n5 kHz do 100 kHz od 1 nF do 10 nF CMC 0,12 %\n100 kHz do 200 kHz od 1 nF do 10 nF CMC 0,13 %\n200 kHz do 500 kHz od 1 nF do 10 nF CMC 0,15 %\n500 kHz do 1 MHz od 1 nF do 10 nF CMC 0,50 %\n50 Hz do 100 Hz od 10 nF do 100 nF CMC 0,20 %\n100 Hz do 5 kHz od 10 nF do 100 nF CMC 0,10 %\n5 kHz do 50 kHz od 10 nF do 100 nF CMC 0,12 %\n50 kHz do 200 kHz od 10 nF do 100 nF CMC 0,20 %\n200 kHz do 500 kHz od 10 nF do 100 nF CMC 0,25 %\n500 kHz do 1 MHz od 10 nF do 100 nF CMC 0,55 %\n50 Hz do 100 Hz od 100 nF do 1000 nF CMC 0,17 %\n100 Hz do 500 Hz od 100 nF do 1000 nF CMC 0,10 %\n500 Hz do 5 kHz od 100 nF do 1000 nF CMC 0,12 %\n5 kHz do 50 kHz od 100 nF do 1000 nF CMC 0,20 %\n50 kHz do 100 kHz od 100 nF do 1000 nF CMC 0,25 %\n100 kHz do 200 kHz od 100 nF do 1000 nF CMC 0,30 %\n200 kHz do 1 MHz od 100 nF do 1000 nF CMC 0,45 %\n20 Hz do 100 Hz od 1 µF do 10 µF CMC 0,16 %\n100 Hz do 500 Hz od 1 µF do 10 µF CMC 0,10 %\n500 Hz do 2 kHz od 1 µF do 10 µF CMC 0,20 %\n2 kHz do 5 kHz od 1 µF do 10 µF CMC 0,22 %\n5 kHz do 10 kHz od 1 µF do 10 µF CMC 0,25 %\n10 kHz do 20 kHz od 1 µF do 10 µF CMC 0,30 %\n20 kHz do 100 kHz od 1 µF do 10 µF CMC (C/40 + 0,20) %\n20 Hz do 50 Hz od 10 µF do 100 µF CMC 0,17 %\n50 Hz do 200 Hz od 10 µF do 100 µF CMC 0,20 %\n200 Hz do 500 Hz od 10 µF do 100 µF CMC 0,25 %\n500 Hz do 1 kHz od 10 µF do 100 µF CMC 0,30 %\n1 kHz do 2 kHz od 10 µF do 100 µF CMC 0,35 %\n2 kHz do 5 kHz od 10 µF do 100 µF CMC (C/500 + 0,25) %\n5 kHz do 10 kHz od 10 µF do 100 µF CMC (C/250 + 0,25) %\n10 kHz do 20 kHz od 10 µF do 100 µF CMC (C/120 + 0,25) %\n20 Hz do 200 Hz od 100 µF do 1000 µF CMC (C/3500 + 0,15) %\n200 Hz do 500 Hz od 100 µF do 1000 µF CMC (C/2800 + 0,20) %\n500 Hz do 1 kHz od 100 µF do 1000 µF CMC (C/1900 + 0,30) %\n1 kHz do 2 kHz od 100 µF do 1000 µF CMC (C/1000 + 0,30) %\n2 kHz do 5 kHz od 100 µF do 1000 µF CMC (C/500 + 0,30) %\n20 Hz do 50 Hz od 1000 µF do 10000 µF CMC (C/12000 + 0,30) %\n50 Hz do 100 Hz od 1000 µF do 10000 µF CMC (C/9000 + 0,30) %\n100 Hz do 200 Hz od 1000 µF do 10000 µF CMC (C/5000 + 0,20) %\nPomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC","reference":"MKE-Z2","norm_bases":["MKE-Z2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pojemność / wzorce, dekady, mierniki pojemności, mostki RLC Wzorcowanie – wielkości elektryczne Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC 1 kHz do 2 kHz od 1 pF do 10 pF CMC 0,10 % + 0,135 pF 2 kHz do 5 kHz od 1 pF do 10 pF CMC 0,10 % + 0,062 pF 5 kHz do 10 kHz od 1 pF do 10 pF CMC 0,10 % + 0,023 pF 10 kHz do 20 kHz od 1 pF do 10 pF CMC 0,17 % + 0,011 pF 20 kHz do 50 kHz od 1 pF do 10 pF CMC 0,22 % + 0,002 pF 50 kHz do 100 kHz od 1 pF do 10 pF CMC 0,28 % + 0,010 pF 100 kHz do 500 kHz od 1 pF do 10 pF CMC 0,40 % + 0,005 pF 500 kHz do 1 MHz od 1 pF do 10 pF CMC 0,55 % + 0,002 pF 500 Hz do 1 kHz od 10 pF do 100 pF CMC 0,10 % + 0,30 pF 1 kHz do 2 kHz od 10 pF do 100 pF CMC 0,10 % + 0,15 pF 2 kHz do 5 kHz od 10 pF do 100 pF CMC 0,10 % + 0,07 pF 5 kHz do 10 kHz od 10 pF do 100 pF CMC 0,10 % + 0,03 pF 10 kHz do 50 kHz od 10 pF do 100 pF CMC 0,15 % + 0,015 pF 50 kHz do 500 kHz od 10 pF do 100 pF CMC 0,15 % + 0,030 pF 500 kHz do 1 MHz od 10 pF do 100 pF CMC 0,40 % + 0,020 pF 100 Hz do 200 Hz od 100 pF do 1000 pF CMC 0,10 % + 2 pF 200 Hz do 500 Hz od 100 pF do 1000 pF CMC 0,10 % + 0,85 pF 500 Hz do 1 kHz od 100 pF do 1000 pF CMC 0,10 % + 0,30 pF 1 kHz do 2 kHz od 100 pF do 1000 pF CMC 0,10 % + 0,15 pF 2 kHz do 500 kHz od 100 pF do 1000 pF CMC 0,15 % 500 kHz do 1 MH od 100 pF do 1000 pF CMC 0,35 % 50 Hz do 100 Hz od 1 nF do 10 nF CMC 0,15 % + 0,005 nF 100 Hz do 500 Hz od 1 nF do 10 nF CMC 0,10 % + 0,002 pF 500 Hz do 5 kHz od 1 nF do 10 nF CMC 0,10 % 5 kHz do 100 kHz od 1 nF do 10 nF CMC 0,12 % 100 kHz do 200 kHz od 1 nF do 10 nF CMC 0,13 % 200 kHz do 500 kHz od 1 nF do 10 nF CMC 0,15 % 500 kHz do 1 MHz od 1 nF do 10 nF CMC 0,50 % 50 Hz do 100 Hz od 10 nF do 100 nF CMC 0,20 % 100 Hz do 5 kHz od 10 nF do 100 nF CMC 0,10 % 5 kHz do 50 kHz od 10 nF do 100 nF CMC 0,12 % 50 kHz do 200 kHz od 10 nF do 100 nF CMC 0,20 % 200 kHz do 500 kHz od 10 nF do 100 nF CMC 0,25 % 500 kHz do 1 MHz od 10 nF do 100 nF CMC 0,55 % 50 Hz do 100 Hz od 100 nF do 1000 nF CMC 0,17 % 100 Hz do 500 Hz od 100 nF do 1000 nF CMC 0,10 % 500 Hz do 5 kHz od 100 nF do 1000 nF CMC 0,12 % 5 kHz do 50 kHz od 100 nF do 1000 nF CMC 0,20 % 50 kHz do 100 kHz od 100 nF do 1000 nF CMC 0,25 % 100 kHz do 200 kHz od 100 nF do 1000 nF CMC 0,30 % 200 kHz do 1 MHz od 100 nF do 1000 nF CMC 0,45 % 20 Hz do 100 Hz od 1 µF do 10 µF CMC 0,16 % 100 Hz do 500 Hz od 1 µF do 10 µF CMC 0,10 % 500 Hz do 2 kHz od 1 µF do 10 µF CMC 0,20 % 2 kHz do 5 kHz od 1 µF do 10 µF CMC 0,22 % 5 kHz do 10 kHz od 1 µF do 10 µF CMC 0,25 % 10 kHz do 20 kHz od 1 µF do 10 µF CMC 0,30 % 20 kHz do 100 kHz od 1 µF do 10 µF CMC (C/40 + 0,20) % 20 Hz do 50 Hz od 10 µF do 100 µF CMC 0,17 % 50 Hz do 200 Hz od 10 µF do 100 µF CMC 0,20 % 200 Hz do 500 Hz od 10 µF do 100 µF CMC 0,25 % 500 Hz do 1 kHz od 10 µF do 100 µF CMC 0,30 % 1 kHz do 2 kHz od 10 µF do 100 µF CMC 0,35 % 2 kHz do 5 kHz od 10 µF do 100 µF CMC (C/500 + 0,25) % 5 kHz do 10 kHz od 10 µF do 100 µF CMC (C/250 + 0,25) % 10 kHz do 20 kHz od 10 µF do 100 µF CMC (C/120 + 0,25) % 20 Hz do 200 Hz od 100 µF do 1000 µF CMC (C/3500 + 0,15) % 200 Hz do 500 Hz od 100 µF do 1000 µF CMC (C/2800 + 0,20) % 500 Hz do 1 kHz od 100 µF do 1000 µF CMC (C/1900 + 0,30) % 1 kHz do 2 kHz od 100 µF do 1000 µF CMC (C/1000 + 0,30) % 2 kHz do 5 kHz od 100 µF do 1000 µF CMC (C/500 + 0,30) % 20 Hz do 50 Hz od 1000 µF do 10000 µF CMC (C/12000 + 0,30) % 50 Hz do 100 Hz od 1000 µF do 10000 µF CMC (C/9000 + 0,30) % 100 Hz do 200 Hz od 1000 µF do 10000 µF CMC (C/5000 + 0,20) % Kapacita / Etalony, dekády, měřidla kapacity, RLC mosty Kalibrace – elektrické veličiny Přímé měření nebo porovnání substitucí s etalonovým RLC mostem 1 kHz až 2 kHz 1 pF až 10 pF CMC 0,10 % + 0,135 pF 2 kHz až 5 kHz 1 pF až 10 pF CMC 0,10 % + 0,062 pF 5 kHz až 10 kHz 1 pF až 10 pF CMC 0,10 % + 0,023 pF 10 kHz až 20 kHz 1 pF až 10 pF CMC 0,17 % + 0,011 pF 20 kHz až 50 kHz 1 pF až 10 pF CMC 0,22 % + 0,002 pF 50 kHz až 100 kHz 1 pF až 10 pF CMC 0,28 % + 0,010 pF 100 kHz až 500 kHz 1 pF až 10 pF CMC 0,40 % + 0,005 pF 500 kHz až 1 MHz 1 pF až 10 pF CMC 0,55 % + 0,002 pF 500 Hz až 1 kHz 10 pF až 100 pF CMC 0,10 % + 0,30 pF 1 kHz až 2 kHz 10 pF až 100 pF CMC 0,10 % + 0,15 pF 2 kHz až 5 kHz 10 pF až 100 pF CMC 0,10 % + 0,07 pF 5 kHz až 10 kHz 10 pF až 100 pF CMC 0,10 % + 0,03 pF 10 kHz až 50 kHz 10 pF až 100 pF CMC 0,15 % + 0,015 pF 50 kHz až 500 kHz 10 pF až 100 pF CMC 0,15 % + 0,030 pF 500 kHz až 1 MHz 10 pF až 100 pF CMC 0,40 % + 0,020 pF 100 Hz až 200 Hz 100 pF až 1000 pF CMC 0,10 % + 2 pF 200 Hz až 500 Hz 100 pF až 1000 pF CMC 0,10 % + 0,85 pF 500 Hz až 1 kHz 100 pF až 1000 pF CMC 0,10 % + 0,30 pF 1 kHz až 2 kHz 100 pF až 1000 pF CMC 0,10 % + 0,15 pF 2 kHz až 500 kHz 100 pF až 1000 pF CMC 0,15 % 500 kHz až 1 MH 100 pF až 1000 pF CMC 0,35 % 50 Hz až 100 Hz 1 nF až 10 nF CMC 0,15 % + 0,005 nF 100 Hz až 500 Hz 1 nF až 10 nF CMC 0,10 % + 0,002 pF 500 Hz až 5 kHz 1 nF až 10 nF CMC 0,10 % 5 kHz až 100 kHz 1 nF až 10 nF CMC 0,12 % 100 kHz až 200 kHz 1 nF až 10 nF CMC 0,13 % 200 kHz až 500 kHz 1 nF až 10 nF CMC 0,15 % 500 kHz až 1 MHz 1 nF až 10 nF CMC 0,50 % 50 Hz až 100 Hz 10 nF až 100 nF CMC 0,20 % 100 Hz až 5 kHz 10 nF až 100 nF CMC 0,10 % 5 kHz až 50 kHz 10 nF až 100 nF CMC 0,12 % 50 kHz až 200 kHz 10 nF až 100 nF CMC 0,20 % 200 kHz až 500 kHz 10 nF až 100 nF CMC 0,25 % 500 kHz až 1 MHz 10 nF až 100 nF CMC 0,55 % 50 Hz až 100 Hz 100 nF až 1000 nF CMC 0,17 % 100 Hz až 500 Hz 100 nF až 1000 nF CMC 0,10 % 500 Hz až 5 kHz 100 nF až 1000 nF CMC 0,12 % 5 kHz až 50 kHz 100 nF až 1000 nF CMC 0,20 % 50 kHz až 100 kHz 100 nF až 1000 nF CMC 0,25 % 100 kHz až 200 kHz 100 nF až 1000 nF CMC 0,30 % 200 kHz až 1 MHz 100 nF až 1000 nF CMC 0,45 % 20 Hz až 100 Hz 1 µF až 10 µF CMC 0,16 % 100 Hz až 500 Hz 1 µF až 10 µF CMC 0,10 % 500 Hz až 2 kHz 1 µF až 10 µF CMC 0,20 % 2 kHz až 5 kHz 1 µF až 10 µF CMC 0,22 % 5 kHz až 10 kHz 1 µF až 10 µF CMC 0,25 % 10 kHz až 20 kHz 1 µF až 10 µF CMC 0,30 % 20 kHz až 100 kHz 1 µF až 10 µF CMC (C/40 + 0,20) % 20 Hz až 50 Hz 10 µF až 100 µF CMC 0,17 % 50 Hz až 200 Hz 10 µF až 100 µF CMC 0,20 % 200 Hz až 500 Hz 10 µF až 100 µF CMC 0,25 % 500 Hz až 1 kHz 10 µF až 100 µF CMC 0,30 % 1 kHz až 2 kHz 10 µF až 100 µF CMC 0,35 % 2 kHz až 5 kHz 10 µF až 100 µF CMC (C/500 + 0,25) % 5 kHz až 10 kHz 10 µF až 100 µF CMC (C/250 + 0,25) % 10 kHz až 20 kHz 10 µF až 100 µF CMC (C/120 + 0,25) % 20 Hz až 200 Hz 100 µF až 1000 µF CMC (C/3500 + 0,15) % 200 Hz až 500 Hz 100 µF až 1000 µF CMC (C/2800 + 0,20) % 500 Hz až 1 kHz 100 µF až 1000 µF CMC (C/1900 + 0,30) % 1 kHz až 2 kHz 100 µF až 1000 µF CMC (C/1000 + 0,30) % 2 kHz až 5 kHz 100 µF až 1000 µF CMC (C/500 + 0,30) % 20 Hz až 50 Hz 1000 µF až 10000 µF CMC (C/12000 + 0,30) % 50 Hz až 100 Hz 1000 µF až 10000 µF CMC (C/9000 + 0,30) % 100 Hz až 200 Hz 1000 µF až 10000 µF CMC (C/5000 + 0,20) % MKE-Z2 Pojemnosc / wzorce, dekady, mierniki pojemnosci, mostki RLC Wzorcowanie – wielkosci elektryczne Pomiar bezposredni lub porownanie metoda substytucji z wzorcowym mostkiem RLC 1 kHz do 2 kHz od 1 pF do 10 pF CMC 0,10 % + 0,135 pF 2 kHz do 5 kHz od 1 pF do 10 pF CMC 0,10 % + 0,062 pF 5 kHz do 10 kHz od 1 pF do 10 pF CMC 0,10 % + 0,023 pF 10 kHz do 20 kHz od 1 pF do 10 pF CMC 0,17 % + 0,011 pF 20 kHz do 50 kHz od 1 pF do 10 pF CMC 0,22 % + 0,002 pF 50 kHz do 100 kHz od 1 pF do 10 pF CMC 0,28 % + 0,010 pF 100 kHz do 500 kHz od 1 pF do 10 pF CMC 0,40 % + 0,005 pF 500 kHz do 1 MHz od 1 pF do 10 pF CMC 0,55 % + 0,002 pF 500 Hz do 1 kHz od 10 pF do 100 pF CMC 0,10 % + 0,30 pF 1 kHz do 2 kHz od 10 pF do 100 pF CMC 0,10 % + 0,15 pF 2 kHz do 5 kHz od 10 pF do 100 pF CMC 0,10 % + 0,07 pF 5 kHz do 10 kHz od 10 pF do 100 pF CMC 0,10 % + 0,03 pF 10 kHz do 50 kHz od 10 pF do 100 pF CMC 0,15 % + 0,015 pF 50 kHz do 500 kHz od 10 pF do 100 pF CMC 0,15 % + 0,030 pF 500 kHz do 1 MHz od 10 pF do 100 pF CMC 0,40 % + 0,020 pF 100 Hz do 200 Hz od 100 pF do 1000 pF CMC 0,10 % + 2 pF 200 Hz do 500 Hz od 100 pF do 1000 pF CMC 0,10 % + 0,85 pF 500 Hz do 1 kHz od 100 pF do 1000 pF CMC 0,10 % + 0,30 pF 1 kHz do 2 kHz od 100 pF do 1000 pF CMC 0,10 % + 0,15 pF 2 kHz do 500 kHz od 100 pF do 1000 pF CMC 0,15 % 500 kHz do 1 MH od 100 pF do 1000 pF CMC 0,35 % 50 Hz do 100 Hz od 1 nF do 10 nF CMC 0,15 % + 0,005 nF 100 Hz do 500 Hz od 1 nF do 10 nF CMC 0,10 % + 0,002 pF 500 Hz do 5 kHz od 1 nF do 10 nF CMC 0,10 % 5 kHz do 100 kHz od 1 nF do 10 nF CMC 0,12 % 100 kHz do 200 kHz od 1 nF do 10 nF CMC 0,13 % 200 kHz do 500 kHz od 1 nF do 10 nF CMC 0,15 % 500 kHz do 1 MHz od 1 nF do 10 nF CMC 0,50 % 50 Hz do 100 Hz od 10 nF do 100 nF CMC 0,20 % 100 Hz do 5 kHz od 10 nF do 100 nF CMC 0,10 % 5 kHz do 50 kHz od 10 nF do 100 nF CMC 0,12 % 50 kHz do 200 kHz od 10 nF do 100 nF CMC 0,20 % 200 kHz do 500 kHz od 10 nF do 100 nF CMC 0,25 % 500 kHz do 1 MHz od 10 nF do 100 nF CMC 0,55 % 50 Hz do 100 Hz od 100 nF do 1000 nF CMC 0,17 % 100 Hz do 500 Hz od 100 nF do 1000 nF CMC 0,10 % 500 Hz do 5 kHz od 100 nF do 1000 nF CMC 0,12 % 5 kHz do 50 kHz od 100 nF do 1000 nF CMC 0,20 % 50 kHz do 100 kHz od 100 nF do 1000 nF CMC 0,25 % 100 kHz do 200 kHz od 100 nF do 1000 nF CMC 0,30 % 200 kHz do 1 MHz od 100 nF do 1000 nF CMC 0,45 % 20 Hz do 100 Hz od 1 µF do 10 µF CMC 0,16 % 100 Hz do 500 Hz od 1 µF do 10 µF CMC 0,10 % 500 Hz do 2 kHz od 1 µF do 10 µF CMC 0,20 % 2 kHz do 5 kHz od 1 µF do 10 µF CMC 0,22 % 5 kHz do 10 kHz od 1 µF do 10 µF CMC 0,25 % 10 kHz do 20 kHz od 1 µF do 10 µF CMC 0,30 % 20 kHz do 100 kHz od 1 µF do 10 µF CMC (C/40 + 0,20) % 20 Hz do 50 Hz od 10 µF do 100 µF CMC 0,17 % 50 Hz do 200 Hz od 10 µF do 100 µF CMC 0,20 % 200 Hz do 500 Hz od 10 µF do 100 µF CMC 0,25 % 500 Hz do 1 kHz od 10 µF do 100 µF CMC 0,30 % 1 kHz do 2 kHz od 10 µF do 100 µF CMC 0,35 % 2 kHz do 5 kHz od 10 µF do 100 µF CMC (C/500 + 0,25) % 5 kHz do 10 kHz od 10 µF do 100 µF CMC (C/250 + 0,25) % 10 kHz do 20 kHz od 10 µF do 100 µF CMC (C/120 + 0,25) % 20 Hz do 200 Hz od 100 µF do 1000 µF CMC (C/3500 + 0,15) % 200 Hz do 500 Hz od 100 µF do 1000 µF CMC (C/2800 + 0,20) % 500 Hz do 1 kHz od 100 µF do 1000 µF CMC (C/1900 + 0,30) % 1 kHz do 2 kHz od 100 µF do 1000 µF CMC (C/1000 + 0,30) % 2 kHz do 5 kHz od 100 µF do 1000 µF CMC (C/500 + 0,30) % 20 Hz do 50 Hz od 1000 µF do 10000 µF CMC (C/12000 + 0,30) % 50 Hz do 100 Hz od 1000 µF do 10000 µF CMC (C/9000 + 0,30) % 100 Hz do 200 Hz od 1000 µF do 10000 µF CMC (C/5000 + 0,20) % Kapacita / Etalony, dekady, meridla kapacity, RLC mosty Kalibrace – elektricke veliciny Prime mereni nebo porovnani substituci s etalonovym RLC mostem 1 kHz az 2 kHz 1 pF az 10 pF CMC 0,10 % + 0,135 pF 2 kHz az 5 kHz 1 pF az 10 pF CMC 0,10 % + 0,062 pF 5 kHz az 10 kHz 1 pF az 10 pF CMC 0,10 % + 0,023 pF 10 kHz az 20 kHz 1 pF az 10 pF CMC 0,17 % + 0,011 pF 20 kHz az 50 kHz 1 pF az 10 pF CMC 0,22 % + 0,002 pF 50 kHz az 100 kHz 1 pF az 10 pF CMC 0,28 % + 0,010 pF 100 kHz az 500 kHz 1 pF az 10 pF CMC 0,40 % + 0,005 pF 500 kHz az 1 MHz 1 pF az 10 pF CMC 0,55 % + 0,002 pF 500 Hz az 1 kHz 10 pF az 100 pF CMC 0,10 % + 0,30 pF 1 kHz az 2 kHz 10 pF az 100 pF CMC 0,10 % + 0,15 pF 2 kHz az 5 kHz 10 pF az 100 pF CMC 0,10 % + 0,07 pF 5 kHz az 10 kHz 10 pF az 100 pF CMC 0,10 % + 0,03 pF 10 kHz az 50 kHz 10 pF az 100 pF CMC 0,15 % + 0,015 pF 50 kHz az 500 kHz 10 pF az 100 pF CMC 0,15 % + 0,030 pF 500 kHz az 1 MHz 10 pF az 100 pF CMC 0,40 % + 0,020 pF 100 Hz az 200 Hz 100 pF az 1000 pF CMC 0,10 % + 2 pF 200 Hz az 500 Hz 100 pF az 1000 pF CMC 0,10 % + 0,85 pF 500 Hz az 1 kHz 100 pF az 1000 pF CMC 0,10 % + 0,30 pF 1 kHz az 2 kHz 100 pF az 1000 pF CMC 0,10 % + 0,15 pF 2 kHz az 500 kHz 100 pF az 1000 pF CMC 0,15 % 500 kHz az 1 MH 100 pF az 1000 pF CMC 0,35 % 50 Hz az 100 Hz 1 nF az 10 nF CMC 0,15 % + 0,005 nF 100 Hz az 500 Hz 1 nF az 10 nF CMC 0,10 % + 0,002 pF 500 Hz az 5 kHz 1 nF az 10 nF CMC 0,10 % 5 kHz az 100 kHz 1 nF az 10 nF CMC 0,12 % 100 kHz az 200 kHz 1 nF az 10 nF CMC 0,13 % 200 kHz az 500 kHz 1 nF az 10 nF CMC 0,15 % 500 kHz az 1 MHz 1 nF az 10 nF CMC 0,50 % 50 Hz az 100 Hz 10 nF az 100 nF CMC 0,20 % 100 Hz az 5 kHz 10 nF az 100 nF CMC 0,10 % 5 kHz az 50 kHz 10 nF az 100 nF CMC 0,12 % 50 kHz az 200 kHz 10 nF az 100 nF CMC 0,20 % 200 kHz az 500 kHz 10 nF az 100 nF CMC 0,25 % 500 kHz az 1 MHz 10 nF az 100 nF CMC 0,55 % 50 Hz az 100 Hz 100 nF az 1000 nF CMC 0,17 % 100 Hz az 500 Hz 100 nF az 1000 nF CMC 0,10 % 500 Hz az 5 kHz 100 nF az 1000 nF CMC 0,12 % 5 kHz az 50 kHz 100 nF az 1000 nF CMC 0,20 % 50 kHz az 100 kHz 100 nF az 1000 nF CMC 0,25 % 100 kHz az 200 kHz 100 nF az 1000 nF CMC 0,30 % 200 kHz az 1 MHz 100 nF az 1000 nF CMC 0,45 % 20 Hz az 100 Hz 1 µF az 10 µF CMC 0,16 % 100 Hz az 500 Hz 1 µF az 10 µF CMC 0,10 % 500 Hz az 2 kHz 1 µF az 10 µF CMC 0,20 % 2 kHz az 5 kHz 1 µF az 10 µF CMC 0,22 % 5 kHz az 10 kHz 1 µF az 10 µF CMC 0,25 % 10 kHz az 20 kHz 1 µF az 10 µF CMC 0,30 % 20 kHz az 100 kHz 1 µF az 10 µF CMC (C/40 + 0,20) % 20 Hz az 50 Hz 10 µF az 100 µF CMC 0,17 % 50 Hz az 200 Hz 10 µF az 100 µF CMC 0,20 % 200 Hz az 500 Hz 10 µF az 100 µF CMC 0,25 % 500 Hz az 1 kHz 10 µF az 100 µF CMC 0,30 % 1 kHz az 2 kHz 10 µF az 100 µF CMC 0,35 % 2 kHz az 5 kHz 10 µF az 100 µF CMC (C/500 + 0,25) % 5 kHz az 10 kHz 10 µF az 100 µF CMC (C/250 + 0,25) % 10 kHz az 20 kHz 10 µF az 100 µF CMC (C/120 + 0,25) % 20 Hz az 200 Hz 100 µF az 1000 µF CMC (C/3500 + 0,15) % 200 Hz az 500 Hz 100 µF az 1000 µF CMC (C/2800 + 0,20) % 500 Hz az 1 kHz 100 µF az 1000 µF CMC (C/1900 + 0,30) % 1 kHz az 2 kHz 100 µF az 1000 µF CMC (C/1000 + 0,30) % 2 kHz az 5 kHz 100 µF az 1000 µF CMC (C/500 + 0,30) % 20 Hz az 50 Hz 1000 µF az 10000 µF CMC (C/12000 + 0,30) % 50 Hz az 100 Hz 1000 µF az 10000 µF CMC (C/9000 + 0,30) % 100 Hz az 200 Hz 1000 µF az 10000 µF CMC (C/5000 + 0,20) % MKE-Z2","search_en":"Capacitance / Standards, boxes, capacitance meters, RLC bridges Calibration – electrical quantities Direct measurement or comparison by substitution with a reference RLC bridge 1 kHz to 2 kHz 1 pF to 10 pF CMC 0,10 % + 0,135 pF 2 kHz to 5 kHz 1 pF to 10 pF CMC 0,10 % + 0,062 pF 5 kHz to 10 kHz 1 pF to 10 pF CMC 0,10 % + 0,023 pF 10 kHz to 20 kHz 1 pF to 10 pF CMC 0,17 % + 0,011 pF 20 kHz to 50 kHz 1 pF to 10 pF CMC 0,22 % + 0,002 pF 50 kHz to 100 kHz 1 pF to 10 pF CMC 0,28 % + 0,010 pF 100 kHz to 500 kHz 1 pF to 10 pF CMC 0,40 % + 0,005 pF 500 kHz to 1 MHz 1 pF to 10 pF CMC 0,55 % + 0,002 pF 500 Hz to 1 kHz 10 pF to 100 pF CMC 0,10 % + 0,30 pF 1 kHz to 2 kHz 10 pF to 100 pF CMC 0,10 % + 0,15 pF 2 kHz to 5 kHz 10 pF to 100 pF CMC 0,10 % + 0,07 pF 5 kHz to 10 kHz 10 pF to 100 pF CMC 0,10 % + 0,03 pF 10 kHz to 50 kHz 10 pF to 100 pF CMC 0,15 % + 0,015 pF 50 kHz to 500 kHz 10 pF to 100 pF CMC 0,15 % + 0,030 pF 500 kHz to 1 MHz 10 pF to 100 pF CMC 0,40 % + 0,020 pF 100 Hz to 200 Hz 100 pF to 1000 pF CMC 0,10 % + 2 pF 200 Hz to 500 Hz 100 pF to 1000 pF CMC 0,10 % + 0,85 pF 500 Hz to 1 kHz 100 pF to 1000 pF CMC 0,10 % + 0,30 pF 1 kHz to 2 kHz 100 pF to 1000 pF CMC 0,10 % + 0,15 pF 2 kHz to 500 kHz 100 pF to 1000 pF CMC 0,15 % 500 kHz to 1 MH 100 pF to 1000 pF CMC 0,35 % 50 Hz to 100 Hz 1 nF to 10 nF CMC 0,15 % + 0,005 nF 100 Hz to 500 Hz 1 nF to 10 nF CMC 0,10 % + 0,002 pF 500 Hz to 5 kHz 1 nF to 10 nF CMC 0,10 % 5 kHz to 100 kHz 1 nF to 10 nF CMC 0,12 % 100 kHz to 200 kHz 1 nF to 10 nF CMC 0,13 % 200 kHz to 500 kHz 1 nF to 10 nF CMC 0,15 % 500 kHz to 1 MHz 1 nF to 10 nF CMC 0,50 % 50 Hz to 100 Hz 10 nF to 100 nF CMC 0,20 % 100 Hz to 5 kHz 10 nF to 100 nF CMC 0,10 % 5 kHz to 50 kHz 10 nF to 100 nF CMC 0,12 % 50 kHz to 200 kHz 10 nF to 100 nF CMC 0,20 % 200 kHz to 500 kHz 10 nF to 100 nF CMC 0,25 % 500 kHz to 1 MHz 10 nF to 100 nF CMC 0,55 % 50 Hz to 100 Hz 100 nF to 1000 nF CMC 0,17 % 100 Hz to 500 Hz 100 nF to 1000 nF CMC 0,10 % 500 Hz to 5 kHz 100 nF to 1000 nF CMC 0,12 % 5 kHz to 50 kHz 100 nF to 1000 nF CMC 0,20 % 50 kHz to 100 kHz 100 nF to 1000 nF CMC 0,25 % 100 kHz to 200 kHz 100 nF to 1000 nF CMC 0,30 % 200 kHz to 1 MHz 100 nF to 1000 nF CMC 0,45 % 20 Hz to 100 Hz 1 µF to 10 µF CMC 0,16 % 100 Hz to 500 Hz 1 µF to 10 µF CMC 0,10 % 500 Hz to 2 kHz 1 µF to 10 µF CMC 0,20 % 2 kHz to 5 kHz 1 µF to 10 µF CMC 0,22 % 5 kHz to 10 kHz 1 µF to 10 µF CMC 0,25 % 10 kHz to 20 kHz 1 µF to 10 µF CMC 0,30 % 20 kHz to 100 kHz 1 µF to 10 µF CMC (C/40 + 0,20) % 20 Hz to 50 Hz 10 µF to 100 µF CMC 0,17 % 50 Hz to 200 Hz 10 µF to 100 µF CMC 0,20 % 200 Hz to 500 Hz 10 µF to 100 µF CMC 0,25 % 500 Hz to 1 kHz 10 µF to 100 µF CMC 0,30 % 1 kHz to 2 kHz 10 µF to 100 µF CMC 0,35 % 2 kHz to 5 kHz 10 µF to 100 µF CMC (C/500 + 0,25) % 5 kHz to 10 kHz 10 µF to 100 µF CMC (C/250 + 0,25) % 10 kHz to 20 kHz 10 µF to 100 µF CMC (C/120 + 0,25) % 20 Hz to 200 Hz 100 µF to 1000 µF CMC (C/3500 + 0,15) % 200 Hz to 500 Hz 100 µF to 1000 µF CMC (C/2800 + 0,20) % 500 Hz to 1 kHz 100 µF to 1000 µF CMC (C/1900 + 0,30) % 1 kHz to 2 kHz 100 µF to 1000 µF CMC (C/1000 + 0,30) % 2 kHz to 5 kHz 100 µF to 1000 µF CMC (C/500 + 0,30) % 20 Hz to 50 Hz 1000 µF to 10000 µF CMC (C/12000 + 0,30) % 50 Hz to 100 Hz 1000 µF to 10000 µF CMC (C/9000 + 0,30) % 100 Hz to 200 Hz 1000 µF to 10000 µF CMC (C/5000 + 0,20) % MKE-Z2","search_zh":"电容 / 标准器、电容箱、电容测量仪、RLC 电桥 校准 – 电学量 直接测量或用标准RLC电桥替代法比较 1 kHz 至 2 kHz 1 pF 至 10 pF CMC 0,10 % + 0,135 pF 2 kHz 至 5 kHz 1 pF 至 10 pF CMC 0,10 % + 0,062 pF 5 kHz 至 10 kHz 1 pF 至 10 pF CMC 0,10 % + 0,023 pF 10 kHz 至 20 kHz 1 pF 至 10 pF CMC 0,17 % + 0,011 pF 20 kHz 至 50 kHz 1 pF 至 10 pF CMC 0,22 % + 0,002 pF 50 kHz 至 100 kHz 1 pF 至 10 pF CMC 0,28 % + 0,010 pF 100 kHz 至 500 kHz 1 pF 至 10 pF CMC 0,40 % + 0,005 pF 500 kHz 至 1 MHz 1 pF 至 10 pF CMC 0,55 % + 0,002 pF 500 Hz 至 1 kHz 10 pF 至 100 pF CMC 0,10 % + 0,30 pF 1 kHz 至 2 kHz 10 pF 至 100 pF CMC 0,10 % + 0,15 pF 2 kHz 至 5 kHz 10 pF 至 100 pF CMC 0,10 % + 0,07 pF 5 kHz 至 10 kHz 10 pF 至 100 pF CMC 0,10 % + 0,03 pF 10 kHz 至 50 kHz 10 pF 至 100 pF CMC 0,15 % + 0,015 pF 50 kHz 至 500 kHz 10 pF 至 100 pF CMC 0,15 % + 0,030 pF 500 kHz 至 1 MHz 10 pF 至 100 pF CMC 0,40 % + 0,020 pF 100 Hz 至 200 Hz 100 pF 至 1000 pF CMC 0,10 % + 2 pF 200 Hz 至 500 Hz 100 pF 至 1000 pF CMC 0,10 % + 0,85 pF 500 Hz 至 1 kHz 100 pF 至 1000 pF CMC 0,10 % + 0,30 pF 1 kHz 至 2 kHz 100 pF 至 1000 pF CMC 0,10 % + 0,15 pF 2 kHz 至 500 kHz 100 pF 至 1000 pF CMC 0,15 % 500 kHz 至 1 MH 100 pF 至 1000 pF CMC 0,35 % 50 Hz 至 100 Hz 1 nF 至 10 nF CMC 0,15 % + 0,005 nF 100 Hz 至 500 Hz 1 nF 至 10 nF CMC 0,10 % + 0,002 pF 500 Hz 至 5 kHz 1 nF 至 10 nF CMC 0,10 % 5 kHz 至 100 kHz 1 nF 至 10 nF CMC 0,12 % 100 kHz 至 200 kHz 1 nF 至 10 nF CMC 0,13 % 200 kHz 至 500 kHz 1 nF 至 10 nF CMC 0,15 % 500 kHz 至 1 MHz 1 nF 至 10 nF CMC 0,50 % 50 Hz 至 100 Hz 10 nF 至 100 nF CMC 0,20 % 100 Hz 至 5 kHz 10 nF 至 100 nF CMC 0,10 % 5 kHz 至 50 kHz 10 nF 至 100 nF CMC 0,12 % 50 kHz 至 200 kHz 10 nF 至 100 nF CMC 0,20 % 200 kHz 至 500 kHz 10 nF 至 100 nF CMC 0,25 % 500 kHz 至 1 MHz 10 nF 至 100 nF CMC 0,55 % 50 Hz 至 100 Hz 100 nF 至 1000 nF CMC 0,17 % 100 Hz 至 500 Hz 100 nF 至 1000 nF CMC 0,10 % 500 Hz 至 5 kHz 100 nF 至 1000 nF CMC 0,12 % 5 kHz 至 50 kHz 100 nF 至 1000 nF CMC 0,20 % 50 kHz 至 100 kHz 100 nF 至 1000 nF CMC 0,25 % 100 kHz 至 200 kHz 100 nF 至 1000 nF CMC 0,30 % 200 kHz 至 1 MHz 100 nF 至 1000 nF CMC 0,45 % 20 Hz 至 100 Hz 1 µF 至 10 µF CMC 0,16 % 100 Hz 至 500 Hz 1 µF 至 10 µF CMC 0,10 % 500 Hz 至 2 kHz 1 µF 至 10 µF CMC 0,20 % 2 kHz 至 5 kHz 1 µF 至 10 µF CMC 0,22 % 5 kHz 至 10 kHz 1 µF 至 10 µF CMC 0,25 % 10 kHz 至 20 kHz 1 µF 至 10 µF CMC 0,30 % 20 kHz 至 100 kHz 1 µF 至 10 µF CMC (C/40 + 0,20) % 20 Hz 至 50 Hz 10 µF 至 100 µF CMC 0,17 % 50 Hz 至 200 Hz 10 µF 至 100 µF CMC 0,20 % 200 Hz 至 500 Hz 10 µF 至 100 µF CMC 0,25 % 500 Hz 至 1 kHz 10 µF 至 100 µF CMC 0,30 % 1 kHz 至 2 kHz 10 µF 至 100 µF CMC 0,35 % 2 kHz 至 5 kHz 10 µF 至 100 µF CMC (C/500 + 0,25) % 5 kHz 至 10 kHz 10 µF 至 100 µF CMC (C/250 + 0,25) % 10 kHz 至 20 kHz 10 µF 至 100 µF CMC (C/120 + 0,25) % 20 Hz 至 200 Hz 100 µF 至 1000 µF CMC (C/3500 + 0,15) % 200 Hz 至 500 Hz 100 µF 至 1000 µF CMC (C/2800 + 0,20) % 500 Hz 至 1 kHz 100 µF 至 1000 µF CMC (C/1900 + 0,30) % 1 kHz 至 2 kHz 100 µF 至 1000 µF CMC (C/1000 + 0,30) % 2 kHz 至 5 kHz 100 µF 至 1000 µF CMC (C/500 + 0,30) % 20 Hz 至 50 Hz 1000 µF 至 10000 µF CMC (C/12000 + 0,30) % 50 Hz 至 100 Hz 1000 µF 至 10000 µF CMC (C/9000 + 0,30) % 100 Hz 至 200 Hz 1000 µF 至 10000 µF CMC (C/5000 + 0,20) % MKE-Z2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7cff0b1003a4139119b0aebc","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"18","test_object":"Indukcyjność / wzorce indukcyjności, mierniki indukcyjności, mostki RLC","test_object_en":"Inductance / Inductance standards, inductance meters, RLC bridges","test_object_zh":"电感 / 电感标准器、电感测量仪、RLC 电桥","test_object_cs":"Indukčnost / Etalony indukčnosti, měřidla indukčnosti, RLC mosty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 Hz","range":"10 µH","cmc":"0,30 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,040 %"},{"name":"10 kHz","range":"10 µH","cmc":"0,030 %"},{"name":"100 Hz","range":"100 µH","cmc":"0,070 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"10 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"100 Hz","range":"1 mH","cmc":"0,030 %"},{"name":"1 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"10 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"1 H","cmc":"0,020 %"},{"name":"1 kHz","range":"10 H","cmc":"0,030 %"}],"parameters_en":[{"name":"100 Hz","range":"10 µH","cmc":"0,30 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,040 %"},{"name":"10 kHz","range":"10 µH","cmc":"0,030 %"},{"name":"100 Hz","range":"100 µH","cmc":"0,070 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"10 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"100 Hz","range":"1 mH","cmc":"0,030 %"},{"name":"1 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"10 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"1 H","cmc":"0,020 %"},{"name":"1 kHz","range":"10 H","cmc":"0,030 %"}],"parameters_zh":[{"name":"100 Hz","range":"10 µH","cmc":"0,30 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,040 %"},{"name":"10 kHz","range":"10 µH","cmc":"0,030 %"},{"name":"100 Hz","range":"100 µH","cmc":"0,070 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"10 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"100 Hz","range":"1 mH","cmc":"0,030 %"},{"name":"1 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"10 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"1 H","cmc":"0,020 %"},{"name":"1 kHz","range":"10 H","cmc":"0,030 %"}],"parameters_cs":[{"name":"100 Hz","range":"10 µH","cmc":"0,30 %"},{"name":"1 kHz","range":"10 µH","cmc":"0,040 %"},{"name":"10 kHz","range":"10 µH","cmc":"0,030 %"},{"name":"100 Hz","range":"100 µH","cmc":"0,070 %"},{"name":"1 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"10 kHz","range":"100 µH","cmc":"0,020 %"},{"name":"100 Hz","range":"1 mH","cmc":"0,030 %"},{"name":"1 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"10 kHz","range":"1 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"2 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"10 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"100 mH","cmc":"0,020 %"},{"name":"1 kHz","range":"1 H","cmc":"0,020 %"},{"name":"1 kHz","range":"10 H","cmc":"0,030 %"}],"technique":"Porównanie metodą substytucji lub pomiar bezpośredni wzorca indukcyjności","technique_en":"Comparison by substitution or direct measurement of inductance standard","technique_zh":"替代法比较或直接测量电感标准器","technique_cs":"Porovnání substitucí nebo přímé měření etalonu indukčnosti","techniques":["Porównanie metodą substytucji lub pomiar bezpośredni wzorca indukcyjności"],"techniques_en":["Comparison by substitution or direct measurement of inductance standard"],"techniques_zh":["替代法比较或直接测量电感标准器"],"techniques_cs":["Porovnání substitucí nebo přímé měření etalonu indukčnosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n100 Hz 10 µH CMC 0,30 %\n1 kHz 10 µH CMC 0,040 %\n10 kHz 10 µH CMC 0,030 %\n100 Hz 100 µH CMC 0,070 %\n1 kHz 100 µH CMC 0,020 %\n10 kHz 100 µH CMC 0,020 %\n100 Hz 1 mH CMC 0,030 %\n1 kHz 1 mH CMC 0,020 %\n10 kHz 1 mH CMC 0,020 %\n1 kHz 2 mH CMC 0,020 %\n1 kHz 10 mH CMC 0,020 %\n1 kHz 100 mH CMC 0,020 %\n1 kHz 1 H CMC 0,020 %\n1 kHz 10 H CMC 0,030 %\nPorównanie metodą substytucji lub pomiar bezpośredni wzorca indukcyjności","reference":"MKE-Z2","norm_bases":["MKE-Z2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indukcyjność / wzorce indukcyjności, mierniki indukcyjności, mostki RLC Wzorcowanie – wielkości elektryczne Porównanie metodą substytucji lub pomiar bezpośredni wzorca indukcyjności 100 Hz 10 µH CMC 0,30 % 1 kHz 10 µH CMC 0,040 % 10 kHz 10 µH CMC 0,030 % 100 Hz 100 µH CMC 0,070 % 1 kHz 100 µH CMC 0,020 % 10 kHz 100 µH CMC 0,020 % 100 Hz 1 mH CMC 0,030 % 1 kHz 1 mH CMC 0,020 % 10 kHz 1 mH CMC 0,020 % 1 kHz 2 mH CMC 0,020 % 1 kHz 10 mH CMC 0,020 % 1 kHz 100 mH CMC 0,020 % 1 kHz 1 H CMC 0,020 % 1 kHz 10 H CMC 0,030 % Indukčnost / Etalony indukčnosti, měřidla indukčnosti, RLC mosty Kalibrace – elektrické veličiny Porovnání substitucí nebo přímé měření etalonu indukčnosti 100 Hz 10 µH CMC 0,30 % 1 kHz 10 µH CMC 0,040 % 10 kHz 10 µH CMC 0,030 % 100 Hz 100 µH CMC 0,070 % 1 kHz 100 µH CMC 0,020 % 10 kHz 100 µH CMC 0,020 % 100 Hz 1 mH CMC 0,030 % 1 kHz 1 mH CMC 0,020 % 10 kHz 1 mH CMC 0,020 % 1 kHz 2 mH CMC 0,020 % 1 kHz 10 mH CMC 0,020 % 1 kHz 100 mH CMC 0,020 % 1 kHz 1 H CMC 0,020 % 1 kHz 10 H CMC 0,030 % MKE-Z2 Indukcyjnosc / wzorce indukcyjnosci, mierniki indukcyjnosci, mostki RLC Wzorcowanie – wielkosci elektryczne Porownanie metoda substytucji lub pomiar bezposredni wzorca indukcyjnosci 100 Hz 10 µH CMC 0,30 % 1 kHz 10 µH CMC 0,040 % 10 kHz 10 µH CMC 0,030 % 100 Hz 100 µH CMC 0,070 % 1 kHz 100 µH CMC 0,020 % 10 kHz 100 µH CMC 0,020 % 100 Hz 1 mH CMC 0,030 % 1 kHz 1 mH CMC 0,020 % 10 kHz 1 mH CMC 0,020 % 1 kHz 2 mH CMC 0,020 % 1 kHz 10 mH CMC 0,020 % 1 kHz 100 mH CMC 0,020 % 1 kHz 1 H CMC 0,020 % 1 kHz 10 H CMC 0,030 % Indukcnost / Etalony indukcnosti, meridla indukcnosti, RLC mosty Kalibrace – elektricke veliciny Porovnani substituci nebo prime mereni etalonu indukcnosti 100 Hz 10 µH CMC 0,30 % 1 kHz 10 µH CMC 0,040 % 10 kHz 10 µH CMC 0,030 % 100 Hz 100 µH CMC 0,070 % 1 kHz 100 µH CMC 0,020 % 10 kHz 100 µH CMC 0,020 % 100 Hz 1 mH CMC 0,030 % 1 kHz 1 mH CMC 0,020 % 10 kHz 1 mH CMC 0,020 % 1 kHz 2 mH CMC 0,020 % 1 kHz 10 mH CMC 0,020 % 1 kHz 100 mH CMC 0,020 % 1 kHz 1 H CMC 0,020 % 1 kHz 10 H CMC 0,030 % MKE-Z2","search_en":"Inductance / Inductance standards, inductance meters, RLC bridges Calibration – electrical quantities Comparison by substitution or direct measurement of inductance standard 100 Hz 10 µH CMC 0,30 % 1 kHz 10 µH CMC 0,040 % 10 kHz 10 µH CMC 0,030 % 100 Hz 100 µH CMC 0,070 % 1 kHz 100 µH CMC 0,020 % 10 kHz 100 µH CMC 0,020 % 100 Hz 1 mH CMC 0,030 % 1 kHz 1 mH CMC 0,020 % 10 kHz 1 mH CMC 0,020 % 1 kHz 2 mH CMC 0,020 % 1 kHz 10 mH CMC 0,020 % 1 kHz 100 mH CMC 0,020 % 1 kHz 1 H CMC 0,020 % 1 kHz 10 H CMC 0,030 % MKE-Z2","search_zh":"电感 / 电感标准器、电感测量仪、RLC 电桥 校准 – 电学量 替代法比较或直接测量电感标准器 100 Hz 10 µH CMC 0,30 % 1 kHz 10 µH CMC 0,040 % 10 kHz 10 µH CMC 0,030 % 100 Hz 100 µH CMC 0,070 % 1 kHz 100 µH CMC 0,020 % 10 kHz 100 µH CMC 0,020 % 100 Hz 1 mH CMC 0,030 % 1 kHz 1 mH CMC 0,020 % 10 kHz 1 mH CMC 0,020 % 1 kHz 2 mH CMC 0,020 % 1 kHz 10 mH CMC 0,020 % 1 kHz 100 mH CMC 0,020 % 1 kHz 1 H CMC 0,020 % 1 kHz 10 H CMC 0,030 % MKE-Z2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c52375048b5bef7c486e8f2b","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"19","test_object":"Indukcyjność / wzorce indukcyjności, mierniki indukcyjności, dekady, mostki RLC","test_object_en":"Inductance / Inductance standards, meters, boxes, RLC bridges","test_object_zh":"电感 / 电感标准器、电感测量仪、电感箱、RLC 电桥","test_object_cs":"Indukčnost / Etalony indukčnosti, měřidla indukčnosti, dekády, RLC mosty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"1 kHz do 2 kHz","range":"od 1 µH do 10 µH","cmc":"0,25 % + 0,147 µH"},{"name":"2 kHz do 5 kHz","range":"od 1 µH do 10 µH","cmc":"0,25 % + 0,063 µH"},{"name":"5 kHz do 10 kHz","range":"od 1 µH do 10 µH","cmc":"0,25 % + 0,022 µH"},{"name":"10 kHz do 20 kHz","range":"od 1 µH do 10 µH","cmc":"0,25 % + 0,010 µH"},{"name":"20 kHz do 50 kHz","range":"od 1 µH do 10 µH","cmc":"0,25 % + 0,005 µH"},{"name":"50 kHz do 100 kHz","range":"od 1 µH do 10 µH","cmc":"0,25 % + 0,002 µH"},{"name":"100 kHz do 200 kHz","range":"od 1 µH do 10 µH","cmc":"0,32 %"},{"name":"200 kHz do 500 kHz","range":"od 1 µH do 10 µH","cmc":"0,28 %"},{"name":"500 Hz do 1 kHz","range":"od 10 µH do 100 µH","cmc":"0,25 % + 0,35 µH"},{"name":"1 kHz do 2 kHz","range":"od 10 µH do 100 µH","cmc":"0,25 % + 0,15 µH"},{"name":"2 kHz do 5 kHz","range":"od 10 µH do 100 µH","cmc":"0,25 % + 0,06 µH"},{"name":"5 kHz do 10 kHz","range":"od 10 µH do 100 µH","cmc":"0,25 % + 0,02 µH"},{"name":"10 kHz do 20 kHz","range":"od 10 µH do 100 µH","cmc":"0,18 % + 0,02 µH"},{"name":"20 kHz do 50 kHz","range":"od 10 µH do 100 µH","cmc":"0,18 % + 0,01 µH"},{"name":"50 kHz do 500 kHz","range":"od 10 µH do 100 µH","cmc":"0,20 %"},{"name":"100 Hz do 200 Hz","range":"od 100 µH do 1000 µH","cmc":"0,30 % + 3,0 µH"},{"name":"200 Hz do 500 Hz","range":"od 100 µH do 1000 µH","cmc":"0,30 % + 1,2 µH"},{"name":"500 Hz do 1 kHz","range":"od 100 µH do 1000 µH","cmc":"0,30 % + 0,3 µH"},{"name":"1 kHz do 2 kHz","range":"od 100 µH do 1000 µH","cmc":"0,20 % + 0,25 µH"},{"name":"2 kHz do 5 kHz","range":"od 100 µH do 1000 µH","cmc":"0,17 % + 0,15 µH"},{"name":"5 kHz do 10 kHz","range":"od 100 µH do 1000 µH","cmc":"0,22 %"},{"name":"10 kHz do 50 kHz","range":"od 100 µH do 1000 µH","cmc":"0,20 %"},{"name":"50 kHz do 200 kHz","range":"od 100 µH do 1000 µH","cmc":"0,13 %"},{"name":"200 kHz do 500 kHz","range":"od 100 µH do 1000 µH","cmc":"0,15 %"},{"name":"50 Hz do 100 Hz","range":"od 1 mH do 10 mH","cmc":"0,45 % + 0,007 mH"},{"name":"100 Hz do 200 Hz","range":"od 1 mH do 10 mH","cmc":"0,30 % + 0,003 mH"},{"name":"200 Hz do 500 Hz","range":"od 1 mH do 10 mH","cmc":"0,15 % + 0,003 mH"},{"name":"500 Hz do 2 kHz","range":"od 1 mH do 10 mH","cmc":"0,23 %"},{"name":"2 kHz do 5 kHz","range":"od 1 mH do 10 mH","cmc":"0,20 %"},{"name":"5 kHz do 10 kHz","range":"od 1 mH do 10 mH","cmc":"0,15 %"},{"name":"10 kHz do 100 kHz","range":"od 1 mH do 10 mH","cmc":"0,12 %"},{"name":"100 kHz do 200 kHz","range":"od 1 mH do 10 mH","cmc":"0,20 %"},{"name":"200 kHz do 500 kHz","range":"od 1 mH do 10 mH","cmc":"0,25 %"},{"name":"50 Hz do 100 Hz","range":"od 10 mH do 100 mH","cmc":"0,20 % + 0,03 mH"},{"name":"100 Hz do 200 Hz","range":"od 10 mH do 100 mH","cmc":"0,22 %"},{"name":"200 Hz do 500 Hz","range":"od 10 mH do 100 mH","cmc":"0,18 %"},{"name":"500 Hz do 1 kHz","range":"od 10 mH do 100 mH","cmc":"0,10 %"},{"name":"1 kHz do 20 kHz","range":"od 10 mH do 100 mH","cmc":"0,12 %"},{"name":"20 kHz do 50 kHz","range":"od 10 mH do 100 mH","cmc":"0,15 %"},{"name":"50 kHz do 100 kHz","range":"od 10 mH do 100 mH","cmc":"0,30 %"},{"name":"100 kHz do 500 kHz","range":"od 10 mH do 100 mH","cmc":"0,50 %"},{"name":"50 Hz do 100 Hz","range":"od 0,1 H do 1 H","cmc":"0,17 %"},{"name":"100 Hz do 5 kHz","range":"od 0,1 H do 1 H","cmc":"0,10 %"},{"name":"5 kHz do 10 kHz","range":"od 0,1 H do 1 H","cmc":"0,11 %"},{"name":"10 kHz do 20 kHz","range":"od 0,1 H do 1 H","cmc":"0,20 %"},{"name":"20 kHz do 50 kHz","range":"od 0,1 H do 1 H","cmc":"0,25 %"},{"name":"50 kHz do 100 kHz","range":"od 0,1 H do 1 H","cmc":"(L/2 + 0,25) %"},{"name":"50 Hz do 100 Hz","range":"od 1 H do 10 H","cmc":"0,16 %"},{"name":"100 Hz do 1 kHz","range":"od 1 H do 10 H","cmc":"0,10 %"},{"name":"1 kHz do 5 kHz","range":"od 1 H do 10 H","cmc":"0,12 %"},{"name":"5 kHz do 10 kHz","range":"od 1 H do 10 H","cmc":"0,22 %"},{"name":"10 kHz do 20 kHz","range":"od 1 H do 10 H","cmc":"(L/200 + 0,20) %"},{"name":"20 kHz do 50 kHz","range":"od 1 H do 10 H","cmc":"(L/40 + 0,20) %"},{"name":"50 Hz do 100 Hz","range":"od 10 H do 100 H","cmc":"0,16 %"},{"name":"100 Hz do 200 Hz","range":"od 10 H do 100 H","cmc":"0,12 %"},{"name":"200 Hz do 1 kHz","range":"od 10 H do 100 H","cmc":"0,15 %"},{"name":"1 kHz do 2 kHz","range":"od 10 H do 100 H","cmc":"0,20 %"},{"name":"2 kHz do 5 kHz","range":"od 10 H do 100 H","cmc":"(L/400 + 0,10) %"},{"name":"5 kHz do 10 kHz","range":"od 10 H do 100 H","cmc":"(L/240 + 0,20) %"},{"name":"10 kHz do 20 kHz","range":"od 10 H do 100 H","cmc":"(L/110 + 0,20) %"},{"name":"20 kHz do 50 kHz","range":"od 10 H do 100 H","cmc":"(L/45 + 0,20) %"}],"parameters_en":[{"name":"1 kHz to 2 kHz","range":"1 µH to 10 µH","cmc":"0,25 % + 0,147 µH"},{"name":"2 kHz to 5 kHz","range":"1 µH to 10 µH","cmc":"0,25 % + 0,063 µH"},{"name":"5 kHz to 10 kHz","range":"1 µH to 10 µH","cmc":"0,25 % + 0,022 µH"},{"name":"10 kHz to 20 kHz","range":"1 µH to 10 µH","cmc":"0,25 % + 0,010 µH"},{"name":"20 kHz to 50 kHz","range":"1 µH to 10 µH","cmc":"0,25 % + 0,005 µH"},{"name":"50 kHz to 100 kHz","range":"1 µH to 10 µH","cmc":"0,25 % + 0,002 µH"},{"name":"100 kHz to 200 kHz","range":"1 µH to 10 µH","cmc":"0,32 %"},{"name":"200 kHz to 500 kHz","range":"1 µH to 10 µH","cmc":"0,28 %"},{"name":"500 Hz to 1 kHz","range":"10 µH to 100 µH","cmc":"0,25 % + 0,35 µH"},{"name":"1 kHz to 2 kHz","range":"10 µH to 100 µH","cmc":"0,25 % + 0,15 µH"},{"name":"2 kHz to 5 kHz","range":"10 µH to 100 µH","cmc":"0,25 % + 0,06 µH"},{"name":"5 kHz to 10 kHz","range":"10 µH to 100 µH","cmc":"0,25 % + 0,02 µH"},{"name":"10 kHz to 20 kHz","range":"10 µH to 100 µH","cmc":"0,18 % + 0,02 µH"},{"name":"20 kHz to 50 kHz","range":"10 µH to 100 µH","cmc":"0,18 % + 0,01 µH"},{"name":"50 kHz to 500 kHz","range":"10 µH to 100 µH","cmc":"0,20 %"},{"name":"100 Hz to 200 Hz","range":"100 µH to 1000 µH","cmc":"0,30 % + 3,0 µH"},{"name":"200 Hz to 500 Hz","range":"100 µH to 1000 µH","cmc":"0,30 % + 1,2 µH"},{"name":"500 Hz to 1 kHz","range":"100 µH to 1000 µH","cmc":"0,30 % + 0,3 µH"},{"name":"1 kHz to 2 kHz","range":"100 µH to 1000 µH","cmc":"0,20 % + 0,25 µH"},{"name":"2 kHz to 5 kHz","range":"100 µH to 1000 µH","cmc":"0,17 % + 0,15 µH"},{"name":"5 kHz to 10 kHz","range":"100 µH to 1000 µH","cmc":"0,22 %"},{"name":"10 kHz to 50 kHz","range":"100 µH to 1000 µH","cmc":"0,20 %"},{"name":"50 kHz to 200 kHz","range":"100 µH to 1000 µH","cmc":"0,13 %"},{"name":"200 kHz to 500 kHz","range":"100 µH to 1000 µH","cmc":"0,15 %"},{"name":"50 Hz to 100 Hz","range":"1 mH to 10 mH","cmc":"0,45 % + 0,007 mH"},{"name":"100 Hz to 200 Hz","range":"1 mH to 10 mH","cmc":"0,30 % + 0,003 mH"},{"name":"200 Hz to 500 Hz","range":"1 mH to 10 mH","cmc":"0,15 % + 0,003 mH"},{"name":"500 Hz to 2 kHz","range":"1 mH to 10 mH","cmc":"0,23 %"},{"name":"2 kHz to 5 kHz","range":"1 mH to 10 mH","cmc":"0,20 %"},{"name":"5 kHz to 10 kHz","range":"1 mH to 10 mH","cmc":"0,15 %"},{"name":"10 kHz to 100 kHz","range":"1 mH to 10 mH","cmc":"0,12 %"},{"name":"100 kHz to 200 kHz","range":"1 mH to 10 mH","cmc":"0,20 %"},{"name":"200 kHz to 500 kHz","range":"1 mH to 10 mH","cmc":"0,25 %"},{"name":"50 Hz to 100 Hz","range":"10 mH to 100 mH","cmc":"0,20 % + 0,03 mH"},{"name":"100 Hz to 200 Hz","range":"10 mH to 100 mH","cmc":"0,22 %"},{"name":"200 Hz to 500 Hz","range":"10 mH to 100 mH","cmc":"0,18 %"},{"name":"500 Hz to 1 kHz","range":"10 mH to 100 mH","cmc":"0,10 %"},{"name":"1 kHz to 20 kHz","range":"10 mH to 100 mH","cmc":"0,12 %"},{"name":"20 kHz to 50 kHz","range":"10 mH to 100 mH","cmc":"0,15 %"},{"name":"50 kHz to 100 kHz","range":"10 mH to 100 mH","cmc":"0,30 %"},{"name":"100 kHz to 500 kHz","range":"10 mH to 100 mH","cmc":"0,50 %"},{"name":"50 Hz to 100 Hz","range":"0,1 H to 1 H","cmc":"0,17 %"},{"name":"100 Hz to 5 kHz","range":"0,1 H to 1 H","cmc":"0,10 %"},{"name":"5 kHz to 10 kHz","range":"0,1 H to 1 H","cmc":"0,11 %"},{"name":"10 kHz to 20 kHz","range":"0,1 H to 1 H","cmc":"0,20 %"},{"name":"20 kHz to 50 kHz","range":"0,1 H to 1 H","cmc":"0,25 %"},{"name":"50 kHz to 100 kHz","range":"0,1 H to 1 H","cmc":"(L/2 + 0,25) %"},{"name":"50 Hz to 100 Hz","range":"1 H to 10 H","cmc":"0,16 %"},{"name":"100 Hz to 1 kHz","range":"1 H to 10 H","cmc":"0,10 %"},{"name":"1 kHz to 5 kHz","range":"1 H to 10 H","cmc":"0,12 %"},{"name":"5 kHz to 10 kHz","range":"1 H to 10 H","cmc":"0,22 %"},{"name":"10 kHz to 20 kHz","range":"1 H to 10 H","cmc":"(L/200 + 0,20) %"},{"name":"20 kHz to 50 kHz","range":"1 H to 10 H","cmc":"(L/40 + 0,20) %"},{"name":"50 Hz to 100 Hz","range":"10 H to 100 H","cmc":"0,16 %"},{"name":"100 Hz to 200 Hz","range":"10 H to 100 H","cmc":"0,12 %"},{"name":"200 Hz to 1 kHz","range":"10 H to 100 H","cmc":"0,15 %"},{"name":"1 kHz to 2 kHz","range":"10 H to 100 H","cmc":"0,20 %"},{"name":"2 kHz to 5 kHz","range":"10 H to 100 H","cmc":"(L/400 + 0,10) %"},{"name":"5 kHz to 10 kHz","range":"10 H to 100 H","cmc":"(L/240 + 0,20) %"},{"name":"10 kHz to 20 kHz","range":"10 H to 100 H","cmc":"(L/110 + 0,20) %"},{"name":"20 kHz to 50 kHz","range":"10 H to 100 H","cmc":"(L/45 + 0,20) %"}],"parameters_zh":[{"name":"1 kHz 至 2 kHz","range":"1 µH 至 10 µH","cmc":"0,25 % + 0,147 µH"},{"name":"2 kHz 至 5 kHz","range":"1 µH 至 10 µH","cmc":"0,25 % + 0,063 µH"},{"name":"5 kHz 至 10 kHz","range":"1 µH 至 10 µH","cmc":"0,25 % + 0,022 µH"},{"name":"10 kHz 至 20 kHz","range":"1 µH 至 10 µH","cmc":"0,25 % + 0,010 µH"},{"name":"20 kHz 至 50 kHz","range":"1 µH 至 10 µH","cmc":"0,25 % + 0,005 µH"},{"name":"50 kHz 至 100 kHz","range":"1 µH 至 10 µH","cmc":"0,25 % + 0,002 µH"},{"name":"100 kHz 至 200 kHz","range":"1 µH 至 10 µH","cmc":"0,32 %"},{"name":"200 kHz 至 500 kHz","range":"1 µH 至 10 µH","cmc":"0,28 %"},{"name":"500 Hz 至 1 kHz","range":"10 µH 至 100 µH","cmc":"0,25 % + 0,35 µH"},{"name":"1 kHz 至 2 kHz","range":"10 µH 至 100 µH","cmc":"0,25 % + 0,15 µH"},{"name":"2 kHz 至 5 kHz","range":"10 µH 至 100 µH","cmc":"0,25 % + 0,06 µH"},{"name":"5 kHz 至 10 kHz","range":"10 µH 至 100 µH","cmc":"0,25 % + 0,02 µH"},{"name":"10 kHz 至 20 kHz","range":"10 µH 至 100 µH","cmc":"0,18 % + 0,02 µH"},{"name":"20 kHz 至 50 kHz","range":"10 µH 至 100 µH","cmc":"0,18 % + 0,01 µH"},{"name":"50 kHz 至 500 kHz","range":"10 µH 至 100 µH","cmc":"0,20 %"},{"name":"100 Hz 至 200 Hz","range":"100 µH 至 1000 µH","cmc":"0,30 % + 3,0 µH"},{"name":"200 Hz 至 500 Hz","range":"100 µH 至 1000 µH","cmc":"0,30 % + 1,2 µH"},{"name":"500 Hz 至 1 kHz","range":"100 µH 至 1000 µH","cmc":"0,30 % + 0,3 µH"},{"name":"1 kHz 至 2 kHz","range":"100 µH 至 1000 µH","cmc":"0,20 % + 0,25 µH"},{"name":"2 kHz 至 5 kHz","range":"100 µH 至 1000 µH","cmc":"0,17 % + 0,15 µH"},{"name":"5 kHz 至 10 kHz","range":"100 µH 至 1000 µH","cmc":"0,22 %"},{"name":"10 kHz 至 50 kHz","range":"100 µH 至 1000 µH","cmc":"0,20 %"},{"name":"50 kHz 至 200 kHz","range":"100 µH 至 1000 µH","cmc":"0,13 %"},{"name":"200 kHz 至 500 kHz","range":"100 µH 至 1000 µH","cmc":"0,15 %"},{"name":"50 Hz 至 100 Hz","range":"1 mH 至 10 mH","cmc":"0,45 % + 0,007 mH"},{"name":"100 Hz 至 200 Hz","range":"1 mH 至 10 mH","cmc":"0,30 % + 0,003 mH"},{"name":"200 Hz 至 500 Hz","range":"1 mH 至 10 mH","cmc":"0,15 % + 0,003 mH"},{"name":"500 Hz 至 2 kHz","range":"1 mH 至 10 mH","cmc":"0,23 %"},{"name":"2 kHz 至 5 kHz","range":"1 mH 至 10 mH","cmc":"0,20 %"},{"name":"5 kHz 至 10 kHz","range":"1 mH 至 10 mH","cmc":"0,15 %"},{"name":"10 kHz 至 100 kHz","range":"1 mH 至 10 mH","cmc":"0,12 %"},{"name":"100 kHz 至 200 kHz","range":"1 mH 至 10 mH","cmc":"0,20 %"},{"name":"200 kHz 至 500 kHz","range":"1 mH 至 10 mH","cmc":"0,25 %"},{"name":"50 Hz 至 100 Hz","range":"10 mH 至 100 mH","cmc":"0,20 % + 0,03 mH"},{"name":"100 Hz 至 200 Hz","range":"10 mH 至 100 mH","cmc":"0,22 %"},{"name":"200 Hz 至 500 Hz","range":"10 mH 至 100 mH","cmc":"0,18 %"},{"name":"500 Hz 至 1 kHz","range":"10 mH 至 100 mH","cmc":"0,10 %"},{"name":"1 kHz 至 20 kHz","range":"10 mH 至 100 mH","cmc":"0,12 %"},{"name":"20 kHz 至 50 kHz","range":"10 mH 至 100 mH","cmc":"0,15 %"},{"name":"50 kHz 至 100 kHz","range":"10 mH 至 100 mH","cmc":"0,30 %"},{"name":"100 kHz 至 500 kHz","range":"10 mH 至 100 mH","cmc":"0,50 %"},{"name":"50 Hz 至 100 Hz","range":"0,1 H 至 1 H","cmc":"0,17 %"},{"name":"100 Hz 至 5 kHz","range":"0,1 H 至 1 H","cmc":"0,10 %"},{"name":"5 kHz 至 10 kHz","range":"0,1 H 至 1 H","cmc":"0,11 %"},{"name":"10 kHz 至 20 kHz","range":"0,1 H 至 1 H","cmc":"0,20 %"},{"name":"20 kHz 至 50 kHz","range":"0,1 H 至 1 H","cmc":"0,25 %"},{"name":"50 kHz 至 100 kHz","range":"0,1 H 至 1 H","cmc":"(L/2 + 0,25) %"},{"name":"50 Hz 至 100 Hz","range":"1 H 至 10 H","cmc":"0,16 %"},{"name":"100 Hz 至 1 kHz","range":"1 H 至 10 H","cmc":"0,10 %"},{"name":"1 kHz 至 5 kHz","range":"1 H 至 10 H","cmc":"0,12 %"},{"name":"5 kHz 至 10 kHz","range":"1 H 至 10 H","cmc":"0,22 %"},{"name":"10 kHz 至 20 kHz","range":"1 H 至 10 H","cmc":"(L/200 + 0,20) %"},{"name":"20 kHz 至 50 kHz","range":"1 H 至 10 H","cmc":"(L/40 + 0,20) %"},{"name":"50 Hz 至 100 Hz","range":"10 H 至 100 H","cmc":"0,16 %"},{"name":"100 Hz 至 200 Hz","range":"10 H 至 100 H","cmc":"0,12 %"},{"name":"200 Hz 至 1 kHz","range":"10 H 至 100 H","cmc":"0,15 %"},{"name":"1 kHz 至 2 kHz","range":"10 H 至 100 H","cmc":"0,20 %"},{"name":"2 kHz 至 5 kHz","range":"10 H 至 100 H","cmc":"(L/400 + 0,10) %"},{"name":"5 kHz 至 10 kHz","range":"10 H 至 100 H","cmc":"(L/240 + 0,20) %"},{"name":"10 kHz 至 20 kHz","range":"10 H 至 100 H","cmc":"(L/110 + 0,20) %"},{"name":"20 kHz 至 50 kHz","range":"10 H 至 100 H","cmc":"(L/45 + 0,20) %"}],"parameters_cs":[{"name":"1 kHz až 2 kHz","range":"1 µH až 10 µH","cmc":"0,25 % + 0,147 µH"},{"name":"2 kHz až 5 kHz","range":"1 µH až 10 µH","cmc":"0,25 % + 0,063 µH"},{"name":"5 kHz až 10 kHz","range":"1 µH až 10 µH","cmc":"0,25 % + 0,022 µH"},{"name":"10 kHz až 20 kHz","range":"1 µH až 10 µH","cmc":"0,25 % + 0,010 µH"},{"name":"20 kHz až 50 kHz","range":"1 µH až 10 µH","cmc":"0,25 % + 0,005 µH"},{"name":"50 kHz až 100 kHz","range":"1 µH až 10 µH","cmc":"0,25 % + 0,002 µH"},{"name":"100 kHz až 200 kHz","range":"1 µH až 10 µH","cmc":"0,32 %"},{"name":"200 kHz až 500 kHz","range":"1 µH až 10 µH","cmc":"0,28 %"},{"name":"500 Hz až 1 kHz","range":"10 µH až 100 µH","cmc":"0,25 % + 0,35 µH"},{"name":"1 kHz až 2 kHz","range":"10 µH až 100 µH","cmc":"0,25 % + 0,15 µH"},{"name":"2 kHz až 5 kHz","range":"10 µH až 100 µH","cmc":"0,25 % + 0,06 µH"},{"name":"5 kHz až 10 kHz","range":"10 µH až 100 µH","cmc":"0,25 % + 0,02 µH"},{"name":"10 kHz až 20 kHz","range":"10 µH až 100 µH","cmc":"0,18 % + 0,02 µH"},{"name":"20 kHz až 50 kHz","range":"10 µH až 100 µH","cmc":"0,18 % + 0,01 µH"},{"name":"50 kHz až 500 kHz","range":"10 µH až 100 µH","cmc":"0,20 %"},{"name":"100 Hz až 200 Hz","range":"100 µH až 1000 µH","cmc":"0,30 % + 3,0 µH"},{"name":"200 Hz až 500 Hz","range":"100 µH až 1000 µH","cmc":"0,30 % + 1,2 µH"},{"name":"500 Hz až 1 kHz","range":"100 µH až 1000 µH","cmc":"0,30 % + 0,3 µH"},{"name":"1 kHz až 2 kHz","range":"100 µH až 1000 µH","cmc":"0,20 % + 0,25 µH"},{"name":"2 kHz až 5 kHz","range":"100 µH až 1000 µH","cmc":"0,17 % + 0,15 µH"},{"name":"5 kHz až 10 kHz","range":"100 µH až 1000 µH","cmc":"0,22 %"},{"name":"10 kHz až 50 kHz","range":"100 µH až 1000 µH","cmc":"0,20 %"},{"name":"50 kHz až 200 kHz","range":"100 µH až 1000 µH","cmc":"0,13 %"},{"name":"200 kHz až 500 kHz","range":"100 µH až 1000 µH","cmc":"0,15 %"},{"name":"50 Hz až 100 Hz","range":"1 mH až 10 mH","cmc":"0,45 % + 0,007 mH"},{"name":"100 Hz až 200 Hz","range":"1 mH až 10 mH","cmc":"0,30 % + 0,003 mH"},{"name":"200 Hz až 500 Hz","range":"1 mH až 10 mH","cmc":"0,15 % + 0,003 mH"},{"name":"500 Hz až 2 kHz","range":"1 mH až 10 mH","cmc":"0,23 %"},{"name":"2 kHz až 5 kHz","range":"1 mH až 10 mH","cmc":"0,20 %"},{"name":"5 kHz až 10 kHz","range":"1 mH až 10 mH","cmc":"0,15 %"},{"name":"10 kHz až 100 kHz","range":"1 mH až 10 mH","cmc":"0,12 %"},{"name":"100 kHz až 200 kHz","range":"1 mH až 10 mH","cmc":"0,20 %"},{"name":"200 kHz až 500 kHz","range":"1 mH až 10 mH","cmc":"0,25 %"},{"name":"50 Hz až 100 Hz","range":"10 mH až 100 mH","cmc":"0,20 % + 0,03 mH"},{"name":"100 Hz až 200 Hz","range":"10 mH až 100 mH","cmc":"0,22 %"},{"name":"200 Hz až 500 Hz","range":"10 mH až 100 mH","cmc":"0,18 %"},{"name":"500 Hz až 1 kHz","range":"10 mH až 100 mH","cmc":"0,10 %"},{"name":"1 kHz až 20 kHz","range":"10 mH až 100 mH","cmc":"0,12 %"},{"name":"20 kHz až 50 kHz","range":"10 mH až 100 mH","cmc":"0,15 %"},{"name":"50 kHz až 100 kHz","range":"10 mH až 100 mH","cmc":"0,30 %"},{"name":"100 kHz až 500 kHz","range":"10 mH až 100 mH","cmc":"0,50 %"},{"name":"50 Hz až 100 Hz","range":"0,1 H až 1 H","cmc":"0,17 %"},{"name":"100 Hz až 5 kHz","range":"0,1 H až 1 H","cmc":"0,10 %"},{"name":"5 kHz až 10 kHz","range":"0,1 H až 1 H","cmc":"0,11 %"},{"name":"10 kHz až 20 kHz","range":"0,1 H až 1 H","cmc":"0,20 %"},{"name":"20 kHz až 50 kHz","range":"0,1 H až 1 H","cmc":"0,25 %"},{"name":"50 kHz až 100 kHz","range":"0,1 H až 1 H","cmc":"(L/2 + 0,25) %"},{"name":"50 Hz až 100 Hz","range":"1 H až 10 H","cmc":"0,16 %"},{"name":"100 Hz až 1 kHz","range":"1 H až 10 H","cmc":"0,10 %"},{"name":"1 kHz až 5 kHz","range":"1 H až 10 H","cmc":"0,12 %"},{"name":"5 kHz až 10 kHz","range":"1 H až 10 H","cmc":"0,22 %"},{"name":"10 kHz až 20 kHz","range":"1 H až 10 H","cmc":"(L/200 + 0,20) %"},{"name":"20 kHz až 50 kHz","range":"1 H až 10 H","cmc":"(L/40 + 0,20) %"},{"name":"50 Hz až 100 Hz","range":"10 H až 100 H","cmc":"0,16 %"},{"name":"100 Hz až 200 Hz","range":"10 H až 100 H","cmc":"0,12 %"},{"name":"200 Hz až 1 kHz","range":"10 H až 100 H","cmc":"0,15 %"},{"name":"1 kHz až 2 kHz","range":"10 H až 100 H","cmc":"0,20 %"},{"name":"2 kHz až 5 kHz","range":"10 H až 100 H","cmc":"(L/400 + 0,10) %"},{"name":"5 kHz až 10 kHz","range":"10 H až 100 H","cmc":"(L/240 + 0,20) %"},{"name":"10 kHz až 20 kHz","range":"10 H až 100 H","cmc":"(L/110 + 0,20) %"},{"name":"20 kHz až 50 kHz","range":"10 H až 100 H","cmc":"(L/45 + 0,20) %"}],"technique":"Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC","technique_en":"Direct measurement or comparison by substitution with a reference RLC bridge","technique_zh":"直接测量或用标准RLC电桥替代法比较","technique_cs":"Přímé měření nebo porovnání substitucí s etalonovým RLC mostem","techniques":["Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC"],"techniques_en":["Direct measurement or comparison by substitution with a reference RLC bridge"],"techniques_zh":["直接测量或用标准RLC电桥替代法比较"],"techniques_cs":["Přímé měření nebo porovnání substitucí s etalonovým RLC mostem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n1 kHz do 2 kHz od 1 µH do 10 µH CMC 0,25 % + 0,147 µH\n2 kHz do 5 kHz od 1 µH do 10 µH CMC 0,25 % + 0,063 µH\n5 kHz do 10 kHz od 1 µH do 10 µH CMC 0,25 % + 0,022 µH\n10 kHz do 20 kHz od 1 µH do 10 µH CMC 0,25 % + 0,010 µH\n20 kHz do 50 kHz od 1 µH do 10 µH CMC 0,25 % + 0,005 µH\n50 kHz do 100 kHz od 1 µH do 10 µH CMC 0,25 % + 0,002 µH\n100 kHz do 200 kHz od 1 µH do 10 µH CMC 0,32 %\n200 kHz do 500 kHz od 1 µH do 10 µH CMC 0,28 %\n500 Hz do 1 kHz od 10 µH do 100 µH CMC 0,25 % + 0,35 µH\n1 kHz do 2 kHz od 10 µH do 100 µH CMC 0,25 % + 0,15 µH\n2 kHz do 5 kHz od 10 µH do 100 µH CMC 0,25 % + 0,06 µH\n5 kHz do 10 kHz od 10 µH do 100 µH CMC 0,25 % + 0,02 µH\n10 kHz do 20 kHz od 10 µH do 100 µH CMC 0,18 % + 0,02 µH\n20 kHz do 50 kHz od 10 µH do 100 µH CMC 0,18 % + 0,01 µH\n50 kHz do 500 kHz od 10 µH do 100 µH CMC 0,20 %\n100 Hz do 200 Hz od 100 µH do 1000 µH CMC 0,30 % + 3,0 µH\n200 Hz do 500 Hz od 100 µH do 1000 µH CMC 0,30 % + 1,2 µH\n500 Hz do 1 kHz od 100 µH do 1000 µH CMC 0,30 % + 0,3 µH\n1 kHz do 2 kHz od 100 µH do 1000 µH CMC 0,20 % + 0,25 µH\n2 kHz do 5 kHz od 100 µH do 1000 µH CMC 0,17 % + 0,15 µH\n5 kHz do 10 kHz od 100 µH do 1000 µH CMC 0,22 %\n10 kHz do 50 kHz od 100 µH do 1000 µH CMC 0,20 %\n50 kHz do 200 kHz od 100 µH do 1000 µH CMC 0,13 %\n200 kHz do 500 kHz od 100 µH do 1000 µH CMC 0,15 %\n50 Hz do 100 Hz od 1 mH do 10 mH CMC 0,45 % + 0,007 mH\n100 Hz do 200 Hz od 1 mH do 10 mH CMC 0,30 % + 0,003 mH\n200 Hz do 500 Hz od 1 mH do 10 mH CMC 0,15 % + 0,003 mH\n500 Hz do 2 kHz od 1 mH do 10 mH CMC 0,23 %\n2 kHz do 5 kHz od 1 mH do 10 mH CMC 0,20 %\n5 kHz do 10 kHz od 1 mH do 10 mH CMC 0,15 %\n10 kHz do 100 kHz od 1 mH do 10 mH CMC 0,12 %\n100 kHz do 200 kHz od 1 mH do 10 mH CMC 0,20 %\n200 kHz do 500 kHz od 1 mH do 10 mH CMC 0,25 %\n50 Hz do 100 Hz od 10 mH do 100 mH CMC 0,20 % + 0,03 mH\n100 Hz do 200 Hz od 10 mH do 100 mH CMC 0,22 %\n200 Hz do 500 Hz od 10 mH do 100 mH CMC 0,18 %\n500 Hz do 1 kHz od 10 mH do 100 mH CMC 0,10 %\n1 kHz do 20 kHz od 10 mH do 100 mH CMC 0,12 %\n20 kHz do 50 kHz od 10 mH do 100 mH CMC 0,15 %\n50 kHz do 100 kHz od 10 mH do 100 mH CMC 0,30 %\n100 kHz do 500 kHz od 10 mH do 100 mH CMC 0,50 %\n50 Hz do 100 Hz od 0,1 H do 1 H CMC 0,17 %\n100 Hz do 5 kHz od 0,1 H do 1 H CMC 0,10 %\n5 kHz do 10 kHz od 0,1 H do 1 H CMC 0,11 %\n10 kHz do 20 kHz od 0,1 H do 1 H CMC 0,20 %\n20 kHz do 50 kHz od 0,1 H do 1 H CMC 0,25 %\n50 kHz do 100 kHz od 0,1 H do 1 H CMC (L/2 + 0,25) %\n50 Hz do 100 Hz od 1 H do 10 H CMC 0,16 %\n100 Hz do 1 kHz od 1 H do 10 H CMC 0,10 %\n1 kHz do 5 kHz od 1 H do 10 H CMC 0,12 %\n5 kHz do 10 kHz od 1 H do 10 H CMC 0,22 %\n10 kHz do 20 kHz od 1 H do 10 H CMC (L/200 + 0,20) %\n20 kHz do 50 kHz od 1 H do 10 H CMC (L/40 + 0,20) %\n50 Hz do 100 Hz od 10 H do 100 H CMC 0,16 %\n100 Hz do 200 Hz od 10 H do 100 H CMC 0,12 %\n200 Hz do 1 kHz od 10 H do 100 H CMC 0,15 %\n1 kHz do 2 kHz od 10 H do 100 H CMC 0,20 %\n2 kHz do 5 kHz od 10 H do 100 H CMC (L/400 + 0,10) %\n5 kHz do 10 kHz od 10 H do 100 H CMC (L/240 + 0,20) %\n10 kHz do 20 kHz od 10 H do 100 H CMC (L/110 + 0,20) %\n20 kHz do 50 kHz od 10 H do 100 H CMC (L/45 + 0,20) %\nPomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC","reference":"MKE-Z2","norm_bases":["MKE-Z2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indukcyjność / wzorce indukcyjności, mierniki indukcyjności, dekady, mostki RLC Wzorcowanie – wielkości elektryczne Pomiar bezpośredni lub porównanie metodą substytucji z wzorcowym mostkiem RLC 1 kHz do 2 kHz od 1 µH do 10 µH CMC 0,25 % + 0,147 µH 2 kHz do 5 kHz od 1 µH do 10 µH CMC 0,25 % + 0,063 µH 5 kHz do 10 kHz od 1 µH do 10 µH CMC 0,25 % + 0,022 µH 10 kHz do 20 kHz od 1 µH do 10 µH CMC 0,25 % + 0,010 µH 20 kHz do 50 kHz od 1 µH do 10 µH CMC 0,25 % + 0,005 µH 50 kHz do 100 kHz od 1 µH do 10 µH CMC 0,25 % + 0,002 µH 100 kHz do 200 kHz od 1 µH do 10 µH CMC 0,32 % 200 kHz do 500 kHz od 1 µH do 10 µH CMC 0,28 % 500 Hz do 1 kHz od 10 µH do 100 µH CMC 0,25 % + 0,35 µH 1 kHz do 2 kHz od 10 µH do 100 µH CMC 0,25 % + 0,15 µH 2 kHz do 5 kHz od 10 µH do 100 µH CMC 0,25 % + 0,06 µH 5 kHz do 10 kHz od 10 µH do 100 µH CMC 0,25 % + 0,02 µH 10 kHz do 20 kHz od 10 µH do 100 µH CMC 0,18 % + 0,02 µH 20 kHz do 50 kHz od 10 µH do 100 µH CMC 0,18 % + 0,01 µH 50 kHz do 500 kHz od 10 µH do 100 µH CMC 0,20 % 100 Hz do 200 Hz od 100 µH do 1000 µH CMC 0,30 % + 3,0 µH 200 Hz do 500 Hz od 100 µH do 1000 µH CMC 0,30 % + 1,2 µH 500 Hz do 1 kHz od 100 µH do 1000 µH CMC 0,30 % + 0,3 µH 1 kHz do 2 kHz od 100 µH do 1000 µH CMC 0,20 % + 0,25 µH 2 kHz do 5 kHz od 100 µH do 1000 µH CMC 0,17 % + 0,15 µH 5 kHz do 10 kHz od 100 µH do 1000 µH CMC 0,22 % 10 kHz do 50 kHz od 100 µH do 1000 µH CMC 0,20 % 50 kHz do 200 kHz od 100 µH do 1000 µH CMC 0,13 % 200 kHz do 500 kHz od 100 µH do 1000 µH CMC 0,15 % 50 Hz do 100 Hz od 1 mH do 10 mH CMC 0,45 % + 0,007 mH 100 Hz do 200 Hz od 1 mH do 10 mH CMC 0,30 % + 0,003 mH 200 Hz do 500 Hz od 1 mH do 10 mH CMC 0,15 % + 0,003 mH 500 Hz do 2 kHz od 1 mH do 10 mH CMC 0,23 % 2 kHz do 5 kHz od 1 mH do 10 mH CMC 0,20 % 5 kHz do 10 kHz od 1 mH do 10 mH CMC 0,15 % 10 kHz do 100 kHz od 1 mH do 10 mH CMC 0,12 % 100 kHz do 200 kHz od 1 mH do 10 mH CMC 0,20 % 200 kHz do 500 kHz od 1 mH do 10 mH CMC 0,25 % 50 Hz do 100 Hz od 10 mH do 100 mH CMC 0,20 % + 0,03 mH 100 Hz do 200 Hz od 10 mH do 100 mH CMC 0,22 % 200 Hz do 500 Hz od 10 mH do 100 mH CMC 0,18 % 500 Hz do 1 kHz od 10 mH do 100 mH CMC 0,10 % 1 kHz do 20 kHz od 10 mH do 100 mH CMC 0,12 % 20 kHz do 50 kHz od 10 mH do 100 mH CMC 0,15 % 50 kHz do 100 kHz od 10 mH do 100 mH CMC 0,30 % 100 kHz do 500 kHz od 10 mH do 100 mH CMC 0,50 % 50 Hz do 100 Hz od 0,1 H do 1 H CMC 0,17 % 100 Hz do 5 kHz od 0,1 H do 1 H CMC 0,10 % 5 kHz do 10 kHz od 0,1 H do 1 H CMC 0,11 % 10 kHz do 20 kHz od 0,1 H do 1 H CMC 0,20 % 20 kHz do 50 kHz od 0,1 H do 1 H CMC 0,25 % 50 kHz do 100 kHz od 0,1 H do 1 H CMC (L/2 + 0,25) % 50 Hz do 100 Hz od 1 H do 10 H CMC 0,16 % 100 Hz do 1 kHz od 1 H do 10 H CMC 0,10 % 1 kHz do 5 kHz od 1 H do 10 H CMC 0,12 % 5 kHz do 10 kHz od 1 H do 10 H CMC 0,22 % 10 kHz do 20 kHz od 1 H do 10 H CMC (L/200 + 0,20) % 20 kHz do 50 kHz od 1 H do 10 H CMC (L/40 + 0,20) % 50 Hz do 100 Hz od 10 H do 100 H CMC 0,16 % 100 Hz do 200 Hz od 10 H do 100 H CMC 0,12 % 200 Hz do 1 kHz od 10 H do 100 H CMC 0,15 % 1 kHz do 2 kHz od 10 H do 100 H CMC 0,20 % 2 kHz do 5 kHz od 10 H do 100 H CMC (L/400 + 0,10) % 5 kHz do 10 kHz od 10 H do 100 H CMC (L/240 + 0,20) % 10 kHz do 20 kHz od 10 H do 100 H CMC (L/110 + 0,20) % 20 kHz do 50 kHz od 10 H do 100 H CMC (L/45 + 0,20) % Indukčnost / Etalony indukčnosti, měřidla indukčnosti, dekády, RLC mosty Kalibrace – elektrické veličiny Přímé měření nebo porovnání substitucí s etalonovým RLC mostem 1 kHz až 2 kHz 1 µH až 10 µH CMC 0,25 % + 0,147 µH 2 kHz až 5 kHz 1 µH až 10 µH CMC 0,25 % + 0,063 µH 5 kHz až 10 kHz 1 µH až 10 µH CMC 0,25 % + 0,022 µH 10 kHz až 20 kHz 1 µH až 10 µH CMC 0,25 % + 0,010 µH 20 kHz až 50 kHz 1 µH až 10 µH CMC 0,25 % + 0,005 µH 50 kHz až 100 kHz 1 µH až 10 µH CMC 0,25 % + 0,002 µH 100 kHz až 200 kHz 1 µH až 10 µH CMC 0,32 % 200 kHz až 500 kHz 1 µH až 10 µH CMC 0,28 % 500 Hz až 1 kHz 10 µH až 100 µH CMC 0,25 % + 0,35 µH 1 kHz až 2 kHz 10 µH až 100 µH CMC 0,25 % + 0,15 µH 2 kHz až 5 kHz 10 µH až 100 µH CMC 0,25 % + 0,06 µH 5 kHz až 10 kHz 10 µH až 100 µH CMC 0,25 % + 0,02 µH 10 kHz až 20 kHz 10 µH až 100 µH CMC 0,18 % + 0,02 µH 20 kHz až 50 kHz 10 µH až 100 µH CMC 0,18 % + 0,01 µH 50 kHz až 500 kHz 10 µH až 100 µH CMC 0,20 % 100 Hz až 200 Hz 100 µH až 1000 µH CMC 0,30 % + 3,0 µH 200 Hz až 500 Hz 100 µH až 1000 µH CMC 0,30 % + 1,2 µH 500 Hz až 1 kHz 100 µH až 1000 µH CMC 0,30 % + 0,3 µH 1 kHz až 2 kHz 100 µH až 1000 µH CMC 0,20 % + 0,25 µH 2 kHz až 5 kHz 100 µH až 1000 µH CMC 0,17 % + 0,15 µH 5 kHz až 10 kHz 100 µH až 1000 µH CMC 0,22 % 10 kHz až 50 kHz 100 µH až 1000 µH CMC 0,20 % 50 kHz až 200 kHz 100 µH až 1000 µH CMC 0,13 % 200 kHz až 500 kHz 100 µH až 1000 µH CMC 0,15 % 50 Hz až 100 Hz 1 mH až 10 mH CMC 0,45 % + 0,007 mH 100 Hz až 200 Hz 1 mH až 10 mH CMC 0,30 % + 0,003 mH 200 Hz až 500 Hz 1 mH až 10 mH CMC 0,15 % + 0,003 mH 500 Hz až 2 kHz 1 mH až 10 mH CMC 0,23 % 2 kHz až 5 kHz 1 mH až 10 mH CMC 0,20 % 5 kHz až 10 kHz 1 mH až 10 mH CMC 0,15 % 10 kHz až 100 kHz 1 mH až 10 mH CMC 0,12 % 100 kHz až 200 kHz 1 mH až 10 mH CMC 0,20 % 200 kHz až 500 kHz 1 mH až 10 mH CMC 0,25 % 50 Hz až 100 Hz 10 mH až 100 mH CMC 0,20 % + 0,03 mH 100 Hz až 200 Hz 10 mH až 100 mH CMC 0,22 % 200 Hz až 500 Hz 10 mH až 100 mH CMC 0,18 % 500 Hz až 1 kHz 10 mH až 100 mH CMC 0,10 % 1 kHz až 20 kHz 10 mH až 100 mH CMC 0,12 % 20 kHz až 50 kHz 10 mH až 100 mH CMC 0,15 % 50 kHz až 100 kHz 10 mH až 100 mH CMC 0,30 % 100 kHz až 500 kHz 10 mH až 100 mH CMC 0,50 % 50 Hz až 100 Hz 0,1 H až 1 H CMC 0,17 % 100 Hz až 5 kHz 0,1 H až 1 H CMC 0,10 % 5 kHz až 10 kHz 0,1 H až 1 H CMC 0,11 % 10 kHz až 20 kHz 0,1 H až 1 H CMC 0,20 % 20 kHz až 50 kHz 0,1 H až 1 H CMC 0,25 % 50 kHz až 100 kHz 0,1 H až 1 H CMC (L/2 + 0,25) % 50 Hz až 100 Hz 1 H až 10 H CMC 0,16 % 100 Hz až 1 kHz 1 H až 10 H CMC 0,10 % 1 kHz až 5 kHz 1 H až 10 H CMC 0,12 % 5 kHz až 10 kHz 1 H až 10 H CMC 0,22 % 10 kHz až 20 kHz 1 H až 10 H CMC (L/200 + 0,20) % 20 kHz až 50 kHz 1 H až 10 H CMC (L/40 + 0,20) % 50 Hz až 100 Hz 10 H až 100 H CMC 0,16 % 100 Hz až 200 Hz 10 H až 100 H CMC 0,12 % 200 Hz až 1 kHz 10 H až 100 H CMC 0,15 % 1 kHz až 2 kHz 10 H až 100 H CMC 0,20 % 2 kHz až 5 kHz 10 H až 100 H CMC (L/400 + 0,10) % 5 kHz až 10 kHz 10 H až 100 H CMC (L/240 + 0,20) % 10 kHz až 20 kHz 10 H až 100 H CMC (L/110 + 0,20) % 20 kHz až 50 kHz 10 H až 100 H CMC (L/45 + 0,20) % MKE-Z2 Indukcyjnosc / wzorce indukcyjnosci, mierniki indukcyjnosci, dekady, mostki RLC Wzorcowanie – wielkosci elektryczne Pomiar bezposredni lub porownanie metoda substytucji z wzorcowym mostkiem RLC 1 kHz do 2 kHz od 1 µH do 10 µH CMC 0,25 % + 0,147 µH 2 kHz do 5 kHz od 1 µH do 10 µH CMC 0,25 % + 0,063 µH 5 kHz do 10 kHz od 1 µH do 10 µH CMC 0,25 % + 0,022 µH 10 kHz do 20 kHz od 1 µH do 10 µH CMC 0,25 % + 0,010 µH 20 kHz do 50 kHz od 1 µH do 10 µH CMC 0,25 % + 0,005 µH 50 kHz do 100 kHz od 1 µH do 10 µH CMC 0,25 % + 0,002 µH 100 kHz do 200 kHz od 1 µH do 10 µH CMC 0,32 % 200 kHz do 500 kHz od 1 µH do 10 µH CMC 0,28 % 500 Hz do 1 kHz od 10 µH do 100 µH CMC 0,25 % + 0,35 µH 1 kHz do 2 kHz od 10 µH do 100 µH CMC 0,25 % + 0,15 µH 2 kHz do 5 kHz od 10 µH do 100 µH CMC 0,25 % + 0,06 µH 5 kHz do 10 kHz od 10 µH do 100 µH CMC 0,25 % + 0,02 µH 10 kHz do 20 kHz od 10 µH do 100 µH CMC 0,18 % + 0,02 µH 20 kHz do 50 kHz od 10 µH do 100 µH CMC 0,18 % + 0,01 µH 50 kHz do 500 kHz od 10 µH do 100 µH CMC 0,20 % 100 Hz do 200 Hz od 100 µH do 1000 µH CMC 0,30 % + 3,0 µH 200 Hz do 500 Hz od 100 µH do 1000 µH CMC 0,30 % + 1,2 µH 500 Hz do 1 kHz od 100 µH do 1000 µH CMC 0,30 % + 0,3 µH 1 kHz do 2 kHz od 100 µH do 1000 µH CMC 0,20 % + 0,25 µH 2 kHz do 5 kHz od 100 µH do 1000 µH CMC 0,17 % + 0,15 µH 5 kHz do 10 kHz od 100 µH do 1000 µH CMC 0,22 % 10 kHz do 50 kHz od 100 µH do 1000 µH CMC 0,20 % 50 kHz do 200 kHz od 100 µH do 1000 µH CMC 0,13 % 200 kHz do 500 kHz od 100 µH do 1000 µH CMC 0,15 % 50 Hz do 100 Hz od 1 mH do 10 mH CMC 0,45 % + 0,007 mH 100 Hz do 200 Hz od 1 mH do 10 mH CMC 0,30 % + 0,003 mH 200 Hz do 500 Hz od 1 mH do 10 mH CMC 0,15 % + 0,003 mH 500 Hz do 2 kHz od 1 mH do 10 mH CMC 0,23 % 2 kHz do 5 kHz od 1 mH do 10 mH CMC 0,20 % 5 kHz do 10 kHz od 1 mH do 10 mH CMC 0,15 % 10 kHz do 100 kHz od 1 mH do 10 mH CMC 0,12 % 100 kHz do 200 kHz od 1 mH do 10 mH CMC 0,20 % 200 kHz do 500 kHz od 1 mH do 10 mH CMC 0,25 % 50 Hz do 100 Hz od 10 mH do 100 mH CMC 0,20 % + 0,03 mH 100 Hz do 200 Hz od 10 mH do 100 mH CMC 0,22 % 200 Hz do 500 Hz od 10 mH do 100 mH CMC 0,18 % 500 Hz do 1 kHz od 10 mH do 100 mH CMC 0,10 % 1 kHz do 20 kHz od 10 mH do 100 mH CMC 0,12 % 20 kHz do 50 kHz od 10 mH do 100 mH CMC 0,15 % 50 kHz do 100 kHz od 10 mH do 100 mH CMC 0,30 % 100 kHz do 500 kHz od 10 mH do 100 mH CMC 0,50 % 50 Hz do 100 Hz od 0,1 H do 1 H CMC 0,17 % 100 Hz do 5 kHz od 0,1 H do 1 H CMC 0,10 % 5 kHz do 10 kHz od 0,1 H do 1 H CMC 0,11 % 10 kHz do 20 kHz od 0,1 H do 1 H CMC 0,20 % 20 kHz do 50 kHz od 0,1 H do 1 H CMC 0,25 % 50 kHz do 100 kHz od 0,1 H do 1 H CMC (L/2 + 0,25) % 50 Hz do 100 Hz od 1 H do 10 H CMC 0,16 % 100 Hz do 1 kHz od 1 H do 10 H CMC 0,10 % 1 kHz do 5 kHz od 1 H do 10 H CMC 0,12 % 5 kHz do 10 kHz od 1 H do 10 H CMC 0,22 % 10 kHz do 20 kHz od 1 H do 10 H CMC (L/200 + 0,20) % 20 kHz do 50 kHz od 1 H do 10 H CMC (L/40 + 0,20) % 50 Hz do 100 Hz od 10 H do 100 H CMC 0,16 % 100 Hz do 200 Hz od 10 H do 100 H CMC 0,12 % 200 Hz do 1 kHz od 10 H do 100 H CMC 0,15 % 1 kHz do 2 kHz od 10 H do 100 H CMC 0,20 % 2 kHz do 5 kHz od 10 H do 100 H CMC (L/400 + 0,10) % 5 kHz do 10 kHz od 10 H do 100 H CMC (L/240 + 0,20) % 10 kHz do 20 kHz od 10 H do 100 H CMC (L/110 + 0,20) % 20 kHz do 50 kHz od 10 H do 100 H CMC (L/45 + 0,20) % Indukcnost / Etalony indukcnosti, meridla indukcnosti, dekady, RLC mosty Kalibrace – elektricke veliciny Prime mereni nebo porovnani substituci s etalonovym RLC mostem 1 kHz az 2 kHz 1 µH az 10 µH CMC 0,25 % + 0,147 µH 2 kHz az 5 kHz 1 µH az 10 µH CMC 0,25 % + 0,063 µH 5 kHz az 10 kHz 1 µH az 10 µH CMC 0,25 % + 0,022 µH 10 kHz az 20 kHz 1 µH az 10 µH CMC 0,25 % + 0,010 µH 20 kHz az 50 kHz 1 µH az 10 µH CMC 0,25 % + 0,005 µH 50 kHz az 100 kHz 1 µH az 10 µH CMC 0,25 % + 0,002 µH 100 kHz az 200 kHz 1 µH az 10 µH CMC 0,32 % 200 kHz az 500 kHz 1 µH az 10 µH CMC 0,28 % 500 Hz az 1 kHz 10 µH az 100 µH CMC 0,25 % + 0,35 µH 1 kHz az 2 kHz 10 µH az 100 µH CMC 0,25 % + 0,15 µH 2 kHz az 5 kHz 10 µH az 100 µH CMC 0,25 % + 0,06 µH 5 kHz az 10 kHz 10 µH az 100 µH CMC 0,25 % + 0,02 µH 10 kHz az 20 kHz 10 µH az 100 µH CMC 0,18 % + 0,02 µH 20 kHz az 50 kHz 10 µH az 100 µH CMC 0,18 % + 0,01 µH 50 kHz az 500 kHz 10 µH az 100 µH CMC 0,20 % 100 Hz az 200 Hz 100 µH az 1000 µH CMC 0,30 % + 3,0 µH 200 Hz az 500 Hz 100 µH az 1000 µH CMC 0,30 % + 1,2 µH 500 Hz az 1 kHz 100 µH az 1000 µH CMC 0,30 % + 0,3 µH 1 kHz az 2 kHz 100 µH az 1000 µH CMC 0,20 % + 0,25 µH 2 kHz az 5 kHz 100 µH az 1000 µH CMC 0,17 % + 0,15 µH 5 kHz az 10 kHz 100 µH az 1000 µH CMC 0,22 % 10 kHz az 50 kHz 100 µH az 1000 µH CMC 0,20 % 50 kHz az 200 kHz 100 µH az 1000 µH CMC 0,13 % 200 kHz az 500 kHz 100 µH az 1000 µH CMC 0,15 % 50 Hz az 100 Hz 1 mH az 10 mH CMC 0,45 % + 0,007 mH 100 Hz az 200 Hz 1 mH az 10 mH CMC 0,30 % + 0,003 mH 200 Hz az 500 Hz 1 mH az 10 mH CMC 0,15 % + 0,003 mH 500 Hz az 2 kHz 1 mH az 10 mH CMC 0,23 % 2 kHz az 5 kHz 1 mH az 10 mH CMC 0,20 % 5 kHz az 10 kHz 1 mH az 10 mH CMC 0,15 % 10 kHz az 100 kHz 1 mH az 10 mH CMC 0,12 % 100 kHz az 200 kHz 1 mH az 10 mH CMC 0,20 % 200 kHz az 500 kHz 1 mH az 10 mH CMC 0,25 % 50 Hz az 100 Hz 10 mH az 100 mH CMC 0,20 % + 0,03 mH 100 Hz az 200 Hz 10 mH az 100 mH CMC 0,22 % 200 Hz az 500 Hz 10 mH az 100 mH CMC 0,18 % 500 Hz az 1 kHz 10 mH az 100 mH CMC 0,10 % 1 kHz az 20 kHz 10 mH az 100 mH CMC 0,12 % 20 kHz az 50 kHz 10 mH az 100 mH CMC 0,15 % 50 kHz az 100 kHz 10 mH az 100 mH CMC 0,30 % 100 kHz az 500 kHz 10 mH az 100 mH CMC 0,50 % 50 Hz az 100 Hz 0,1 H az 1 H CMC 0,17 % 100 Hz az 5 kHz 0,1 H az 1 H CMC 0,10 % 5 kHz az 10 kHz 0,1 H az 1 H CMC 0,11 % 10 kHz az 20 kHz 0,1 H az 1 H CMC 0,20 % 20 kHz az 50 kHz 0,1 H az 1 H CMC 0,25 % 50 kHz az 100 kHz 0,1 H az 1 H CMC (L/2 + 0,25) % 50 Hz az 100 Hz 1 H az 10 H CMC 0,16 % 100 Hz az 1 kHz 1 H az 10 H CMC 0,10 % 1 kHz az 5 kHz 1 H az 10 H CMC 0,12 % 5 kHz az 10 kHz 1 H az 10 H CMC 0,22 % 10 kHz az 20 kHz 1 H az 10 H CMC (L/200 + 0,20) % 20 kHz az 50 kHz 1 H az 10 H CMC (L/40 + 0,20) % 50 Hz az 100 Hz 10 H az 100 H CMC 0,16 % 100 Hz az 200 Hz 10 H az 100 H CMC 0,12 % 200 Hz az 1 kHz 10 H az 100 H CMC 0,15 % 1 kHz az 2 kHz 10 H az 100 H CMC 0,20 % 2 kHz az 5 kHz 10 H az 100 H CMC (L/400 + 0,10) % 5 kHz az 10 kHz 10 H az 100 H CMC (L/240 + 0,20) % 10 kHz az 20 kHz 10 H az 100 H CMC (L/110 + 0,20) % 20 kHz az 50 kHz 10 H az 100 H CMC (L/45 + 0,20) % MKE-Z2","search_en":"Inductance / Inductance standards, meters, boxes, RLC bridges Calibration – electrical quantities Direct measurement or comparison by substitution with a reference RLC bridge 1 kHz to 2 kHz 1 µH to 10 µH CMC 0,25 % + 0,147 µH 2 kHz to 5 kHz 1 µH to 10 µH CMC 0,25 % + 0,063 µH 5 kHz to 10 kHz 1 µH to 10 µH CMC 0,25 % + 0,022 µH 10 kHz to 20 kHz 1 µH to 10 µH CMC 0,25 % + 0,010 µH 20 kHz to 50 kHz 1 µH to 10 µH CMC 0,25 % + 0,005 µH 50 kHz to 100 kHz 1 µH to 10 µH CMC 0,25 % + 0,002 µH 100 kHz to 200 kHz 1 µH to 10 µH CMC 0,32 % 200 kHz to 500 kHz 1 µH to 10 µH CMC 0,28 % 500 Hz to 1 kHz 10 µH to 100 µH CMC 0,25 % + 0,35 µH 1 kHz to 2 kHz 10 µH to 100 µH CMC 0,25 % + 0,15 µH 2 kHz to 5 kHz 10 µH to 100 µH CMC 0,25 % + 0,06 µH 5 kHz to 10 kHz 10 µH to 100 µH CMC 0,25 % + 0,02 µH 10 kHz to 20 kHz 10 µH to 100 µH CMC 0,18 % + 0,02 µH 20 kHz to 50 kHz 10 µH to 100 µH CMC 0,18 % + 0,01 µH 50 kHz to 500 kHz 10 µH to 100 µH CMC 0,20 % 100 Hz to 200 Hz 100 µH to 1000 µH CMC 0,30 % + 3,0 µH 200 Hz to 500 Hz 100 µH to 1000 µH CMC 0,30 % + 1,2 µH 500 Hz to 1 kHz 100 µH to 1000 µH CMC 0,30 % + 0,3 µH 1 kHz to 2 kHz 100 µH to 1000 µH CMC 0,20 % + 0,25 µH 2 kHz to 5 kHz 100 µH to 1000 µH CMC 0,17 % + 0,15 µH 5 kHz to 10 kHz 100 µH to 1000 µH CMC 0,22 % 10 kHz to 50 kHz 100 µH to 1000 µH CMC 0,20 % 50 kHz to 200 kHz 100 µH to 1000 µH CMC 0,13 % 200 kHz to 500 kHz 100 µH to 1000 µH CMC 0,15 % 50 Hz to 100 Hz 1 mH to 10 mH CMC 0,45 % + 0,007 mH 100 Hz to 200 Hz 1 mH to 10 mH CMC 0,30 % + 0,003 mH 200 Hz to 500 Hz 1 mH to 10 mH CMC 0,15 % + 0,003 mH 500 Hz to 2 kHz 1 mH to 10 mH CMC 0,23 % 2 kHz to 5 kHz 1 mH to 10 mH CMC 0,20 % 5 kHz to 10 kHz 1 mH to 10 mH CMC 0,15 % 10 kHz to 100 kHz 1 mH to 10 mH CMC 0,12 % 100 kHz to 200 kHz 1 mH to 10 mH CMC 0,20 % 200 kHz to 500 kHz 1 mH to 10 mH CMC 0,25 % 50 Hz to 100 Hz 10 mH to 100 mH CMC 0,20 % + 0,03 mH 100 Hz to 200 Hz 10 mH to 100 mH CMC 0,22 % 200 Hz to 500 Hz 10 mH to 100 mH CMC 0,18 % 500 Hz to 1 kHz 10 mH to 100 mH CMC 0,10 % 1 kHz to 20 kHz 10 mH to 100 mH CMC 0,12 % 20 kHz to 50 kHz 10 mH to 100 mH CMC 0,15 % 50 kHz to 100 kHz 10 mH to 100 mH CMC 0,30 % 100 kHz to 500 kHz 10 mH to 100 mH CMC 0,50 % 50 Hz to 100 Hz 0,1 H to 1 H CMC 0,17 % 100 Hz to 5 kHz 0,1 H to 1 H CMC 0,10 % 5 kHz to 10 kHz 0,1 H to 1 H CMC 0,11 % 10 kHz to 20 kHz 0,1 H to 1 H CMC 0,20 % 20 kHz to 50 kHz 0,1 H to 1 H CMC 0,25 % 50 kHz to 100 kHz 0,1 H to 1 H CMC (L/2 + 0,25) % 50 Hz to 100 Hz 1 H to 10 H CMC 0,16 % 100 Hz to 1 kHz 1 H to 10 H CMC 0,10 % 1 kHz to 5 kHz 1 H to 10 H CMC 0,12 % 5 kHz to 10 kHz 1 H to 10 H CMC 0,22 % 10 kHz to 20 kHz 1 H to 10 H CMC (L/200 + 0,20) % 20 kHz to 50 kHz 1 H to 10 H CMC (L/40 + 0,20) % 50 Hz to 100 Hz 10 H to 100 H CMC 0,16 % 100 Hz to 200 Hz 10 H to 100 H CMC 0,12 % 200 Hz to 1 kHz 10 H to 100 H CMC 0,15 % 1 kHz to 2 kHz 10 H to 100 H CMC 0,20 % 2 kHz to 5 kHz 10 H to 100 H CMC (L/400 + 0,10) % 5 kHz to 10 kHz 10 H to 100 H CMC (L/240 + 0,20) % 10 kHz to 20 kHz 10 H to 100 H CMC (L/110 + 0,20) % 20 kHz to 50 kHz 10 H to 100 H CMC (L/45 + 0,20) % MKE-Z2","search_zh":"电感 / 电感标准器、电感测量仪、电感箱、RLC 电桥 校准 – 电学量 直接测量或用标准RLC电桥替代法比较 1 kHz 至 2 kHz 1 µH 至 10 µH CMC 0,25 % + 0,147 µH 2 kHz 至 5 kHz 1 µH 至 10 µH CMC 0,25 % + 0,063 µH 5 kHz 至 10 kHz 1 µH 至 10 µH CMC 0,25 % + 0,022 µH 10 kHz 至 20 kHz 1 µH 至 10 µH CMC 0,25 % + 0,010 µH 20 kHz 至 50 kHz 1 µH 至 10 µH CMC 0,25 % + 0,005 µH 50 kHz 至 100 kHz 1 µH 至 10 µH CMC 0,25 % + 0,002 µH 100 kHz 至 200 kHz 1 µH 至 10 µH CMC 0,32 % 200 kHz 至 500 kHz 1 µH 至 10 µH CMC 0,28 % 500 Hz 至 1 kHz 10 µH 至 100 µH CMC 0,25 % + 0,35 µH 1 kHz 至 2 kHz 10 µH 至 100 µH CMC 0,25 % + 0,15 µH 2 kHz 至 5 kHz 10 µH 至 100 µH CMC 0,25 % + 0,06 µH 5 kHz 至 10 kHz 10 µH 至 100 µH CMC 0,25 % + 0,02 µH 10 kHz 至 20 kHz 10 µH 至 100 µH CMC 0,18 % + 0,02 µH 20 kHz 至 50 kHz 10 µH 至 100 µH CMC 0,18 % + 0,01 µH 50 kHz 至 500 kHz 10 µH 至 100 µH CMC 0,20 % 100 Hz 至 200 Hz 100 µH 至 1000 µH CMC 0,30 % + 3,0 µH 200 Hz 至 500 Hz 100 µH 至 1000 µH CMC 0,30 % + 1,2 µH 500 Hz 至 1 kHz 100 µH 至 1000 µH CMC 0,30 % + 0,3 µH 1 kHz 至 2 kHz 100 µH 至 1000 µH CMC 0,20 % + 0,25 µH 2 kHz 至 5 kHz 100 µH 至 1000 µH CMC 0,17 % + 0,15 µH 5 kHz 至 10 kHz 100 µH 至 1000 µH CMC 0,22 % 10 kHz 至 50 kHz 100 µH 至 1000 µH CMC 0,20 % 50 kHz 至 200 kHz 100 µH 至 1000 µH CMC 0,13 % 200 kHz 至 500 kHz 100 µH 至 1000 µH CMC 0,15 % 50 Hz 至 100 Hz 1 mH 至 10 mH CMC 0,45 % + 0,007 mH 100 Hz 至 200 Hz 1 mH 至 10 mH CMC 0,30 % + 0,003 mH 200 Hz 至 500 Hz 1 mH 至 10 mH CMC 0,15 % + 0,003 mH 500 Hz 至 2 kHz 1 mH 至 10 mH CMC 0,23 % 2 kHz 至 5 kHz 1 mH 至 10 mH CMC 0,20 % 5 kHz 至 10 kHz 1 mH 至 10 mH CMC 0,15 % 10 kHz 至 100 kHz 1 mH 至 10 mH CMC 0,12 % 100 kHz 至 200 kHz 1 mH 至 10 mH CMC 0,20 % 200 kHz 至 500 kHz 1 mH 至 10 mH CMC 0,25 % 50 Hz 至 100 Hz 10 mH 至 100 mH CMC 0,20 % + 0,03 mH 100 Hz 至 200 Hz 10 mH 至 100 mH CMC 0,22 % 200 Hz 至 500 Hz 10 mH 至 100 mH CMC 0,18 % 500 Hz 至 1 kHz 10 mH 至 100 mH CMC 0,10 % 1 kHz 至 20 kHz 10 mH 至 100 mH CMC 0,12 % 20 kHz 至 50 kHz 10 mH 至 100 mH CMC 0,15 % 50 kHz 至 100 kHz 10 mH 至 100 mH CMC 0,30 % 100 kHz 至 500 kHz 10 mH 至 100 mH CMC 0,50 % 50 Hz 至 100 Hz 0,1 H 至 1 H CMC 0,17 % 100 Hz 至 5 kHz 0,1 H 至 1 H CMC 0,10 % 5 kHz 至 10 kHz 0,1 H 至 1 H CMC 0,11 % 10 kHz 至 20 kHz 0,1 H 至 1 H CMC 0,20 % 20 kHz 至 50 kHz 0,1 H 至 1 H CMC 0,25 % 50 kHz 至 100 kHz 0,1 H 至 1 H CMC (L/2 + 0,25) % 50 Hz 至 100 Hz 1 H 至 10 H CMC 0,16 % 100 Hz 至 1 kHz 1 H 至 10 H CMC 0,10 % 1 kHz 至 5 kHz 1 H 至 10 H CMC 0,12 % 5 kHz 至 10 kHz 1 H 至 10 H CMC 0,22 % 10 kHz 至 20 kHz 1 H 至 10 H CMC (L/200 + 0,20) % 20 kHz 至 50 kHz 1 H 至 10 H CMC (L/40 + 0,20) % 50 Hz 至 100 Hz 10 H 至 100 H CMC 0,16 % 100 Hz 至 200 Hz 10 H 至 100 H CMC 0,12 % 200 Hz 至 1 kHz 10 H 至 100 H CMC 0,15 % 1 kHz 至 2 kHz 10 H 至 100 H CMC 0,20 % 2 kHz 至 5 kHz 10 H 至 100 H CMC (L/400 + 0,10) % 5 kHz 至 10 kHz 10 H 至 100 H CMC (L/240 + 0,20) % 10 kHz 至 20 kHz 10 H 至 100 H CMC (L/110 + 0,20) % 20 kHz 至 50 kHz 10 H 至 100 H CMC (L/45 + 0,20) % MKE-Z2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"58f7abe5632c30640650c6d7","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"20","test_object":"Wartość międzyszczytowa napięcia w.cz. / mierniki napięcia w.cz., oscyloskopy, miliwoltomierze w.cz., analizatory częstotliwości","test_object_en":"HF voltage peak-to-peak value / HF voltage meters, oscilloscopes, HF millivoltmeters, frequency analyzers","test_object_zh":"高频电压峰峰值 / 高频电压测量仪器、示波器、高频毫伏表、频率分析仪","test_object_cs":"Mezivrcholová hodnota vf napětí / Měřidla vf napětí, osciloskopy, vf milivoltmetry, frekvenční analyzátory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 kHz do 300 MHz","range":"od 5 mV do 5 V","cmc":"3,7 %"},{"name":"300 MHz do 550 MHz","range":"od 5 mV do 5 V","cmc":"4,2 %"},{"name":"550 MHz do 1,1 GHz","range":"od 5 mV do 3 V","cmc":"5,2 %"},{"name":"1,1 GHz do 2,5 GHz","range":"od 5 mV do 3 V","cmc":"5,9 %"},{"name":"2,5 GHz do 3,2 GHz","range":"od 5 mV do 2 V","cmc":"5,9 %"}],"parameters_en":[{"name":"100 kHz to 300 MHz","range":"5 mV to 5 V","cmc":"3,7 %"},{"name":"300 MHz to 550 MHz","range":"5 mV to 5 V","cmc":"4,2 %"},{"name":"550 MHz to 1,1 GHz","range":"5 mV to 3 V","cmc":"5,2 %"},{"name":"1,1 GHz to 2,5 GHz","range":"5 mV to 3 V","cmc":"5,9 %"},{"name":"2,5 GHz to 3,2 GHz","range":"5 mV to 2 V","cmc":"5,9 %"}],"parameters_zh":[{"name":"100 kHz 至 300 MHz","range":"5 mV 至 5 V","cmc":"3,7 %"},{"name":"300 MHz 至 550 MHz","range":"5 mV 至 5 V","cmc":"4,2 %"},{"name":"550 MHz 至 1,1 GHz","range":"5 mV 至 3 V","cmc":"5,2 %"},{"name":"1,1 GHz 至 2,5 GHz","range":"5 mV 至 3 V","cmc":"5,9 %"},{"name":"2,5 GHz 至 3,2 GHz","range":"5 mV 至 2 V","cmc":"5,9 %"}],"parameters_cs":[{"name":"100 kHz až 300 MHz","range":"5 mV až 5 V","cmc":"3,7 %"},{"name":"300 MHz až 550 MHz","range":"5 mV až 5 V","cmc":"4,2 %"},{"name":"550 MHz až 1,1 GHz","range":"5 mV až 3 V","cmc":"5,2 %"},{"name":"1,1 GHz až 2,5 GHz","range":"5 mV až 3 V","cmc":"5,9 %"},{"name":"2,5 GHz až 3,2 GHz","range":"5 mV až 2 V","cmc":"5,9 %"}],"technique":"Bezpośrednie generowanie kalibratorem w płaszczyźnie złącza przyłączeniowego BNC 50 Ω","technique_en":"Direct generation with a calibrator in the plane of the connecting BNC connector of 50 Ω","technique_zh":"用校准器在 50 Ω BNC 连接器平面直接产生","technique_cs":"Přímé generování kalibrátorem v rovině připojovacího BNC konektoru 50 Ω","techniques":["Bezpośrednie generowanie kalibratorem w płaszczyźnie złącza przyłączeniowego BNC 50 Ω"],"techniques_en":["Direct generation with a calibrator in the plane of the connecting BNC connector of 50 Ω"],"techniques_zh":["用校准器在 50 Ω BNC 连接器平面直接产生"],"techniques_cs":["Přímé generování kalibrátorem v rovině připojovacího BNC konektoru 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n100 kHz do 300 MHz od 5 mV do 5 V CMC 3,7 %\n300 MHz do 550 MHz od 5 mV do 5 V CMC 4,2 %\n550 MHz do 1,1 GHz od 5 mV do 3 V CMC 5,2 %\n1,1 GHz do 2,5 GHz od 5 mV do 3 V CMC 5,9 %\n2,5 GHz do 3,2 GHz od 5 mV do 2 V CMC 5,9 %\nBezpośrednie generowanie kalibratorem w płaszczyźnie złącza przyłączeniowego BNC 50 Ω","reference":"MKE-UVF1","norm_bases":["MKE-UVF1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wartość międzyszczytowa napięcia w.cz. / mierniki napięcia w.cz., oscyloskopy, miliwoltomierze w.cz., analizatory częstotliwości Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem w płaszczyźnie złącza przyłączeniowego BNC 50 Ω 100 kHz do 300 MHz od 5 mV do 5 V CMC 3,7 % 300 MHz do 550 MHz od 5 mV do 5 V CMC 4,2 % 550 MHz do 1,1 GHz od 5 mV do 3 V CMC 5,2 % 1,1 GHz do 2,5 GHz od 5 mV do 3 V CMC 5,9 % 2,5 GHz do 3,2 GHz od 5 mV do 2 V CMC 5,9 % Mezivrcholová hodnota vf napětí / Měřidla vf napětí, osciloskopy, vf milivoltmetry, frekvenční analyzátory Kalibrace – elektrické veličiny Přímé generování kalibrátorem v rovině připojovacího BNC konektoru 50 Ω 100 kHz až 300 MHz 5 mV až 5 V CMC 3,7 % 300 MHz až 550 MHz 5 mV až 5 V CMC 4,2 % 550 MHz až 1,1 GHz 5 mV až 3 V CMC 5,2 % 1,1 GHz až 2,5 GHz 5 mV až 3 V CMC 5,9 % 2,5 GHz až 3,2 GHz 5 mV až 2 V CMC 5,9 % MKE-UVF1 Wartosc miedzyszczytowa napiecia w.cz. / mierniki napiecia w.cz., oscyloskopy, miliwoltomierze w.cz., analizatory czestotliwosci Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem w plaszczyznie zlacza przylaczeniowego BNC 50 Ω 100 kHz do 300 MHz od 5 mV do 5 V CMC 3,7 % 300 MHz do 550 MHz od 5 mV do 5 V CMC 4,2 % 550 MHz do 1,1 GHz od 5 mV do 3 V CMC 5,2 % 1,1 GHz do 2,5 GHz od 5 mV do 3 V CMC 5,9 % 2,5 GHz do 3,2 GHz od 5 mV do 2 V CMC 5,9 % Mezivrcholova hodnota vf napeti / Meridla vf napeti, osciloskopy, vf milivoltmetry, frekvencni analyzatory Kalibrace – elektricke veliciny Prime generovani kalibratorem v rovine pripojovaciho BNC konektoru 50 Ω 100 kHz az 300 MHz 5 mV az 5 V CMC 3,7 % 300 MHz az 550 MHz 5 mV az 5 V CMC 4,2 % 550 MHz az 1,1 GHz 5 mV az 3 V CMC 5,2 % 1,1 GHz az 2,5 GHz 5 mV az 3 V CMC 5,9 % 2,5 GHz az 3,2 GHz 5 mV az 2 V CMC 5,9 % MKE-UVF1","search_en":"HF voltage peak-to-peak value / HF voltage meters, oscilloscopes, HF millivoltmeters, frequency analyzers Calibration – electrical quantities Direct generation with a calibrator in the plane of the connecting BNC connector of 50 Ω 100 kHz to 300 MHz 5 mV to 5 V CMC 3,7 % 300 MHz to 550 MHz 5 mV to 5 V CMC 4,2 % 550 MHz to 1,1 GHz 5 mV to 3 V CMC 5,2 % 1,1 GHz to 2,5 GHz 5 mV to 3 V CMC 5,9 % 2,5 GHz to 3,2 GHz 5 mV to 2 V CMC 5,9 % MKE-UVF1","search_zh":"高频电压峰峰值 / 高频电压测量仪器、示波器、高频毫伏表、频率分析仪 校准 – 电学量 用校准器在 50 Ω BNC 连接器平面直接产生 100 kHz 至 300 MHz 5 mV 至 5 V CMC 3,7 % 300 MHz 至 550 MHz 5 mV 至 5 V CMC 4,2 % 550 MHz 至 1,1 GHz 5 mV 至 3 V CMC 5,2 % 1,1 GHz 至 2,5 GHz 5 mV 至 3 V CMC 5,9 % 2,5 GHz 至 3,2 GHz 5 mV 至 2 V CMC 5,9 % MKE-UVF1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"42da8e30dcac102e84876939","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"21","test_object":"Wartość skuteczna napięcia w.cz. / mierniki napięcia w.cz., oscyloskopy, miliwoltomierze w.cz., analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe","test_object_en":"HF voltage effective value / HF voltage meters, oscilloscopes, HF millivoltmeters, frequency analyzers, function generators, signal generators","test_object_zh":"高频电压有效值 / 高频电压测量仪器、示波器、高频毫伏表、频率分析仪、函数发生器、信号发生器","test_object_cs":"Efektivní hodnota vf napětí / Měřidla vf napětí, osciloskopy, vf milivoltmetry, frekvenční analyzátory, funkční generátory, signální generátory","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"100 kHz do 100 MHz","range":"od 1 mV do 2 mV","cmc":"3,6 %"},{"name":"100 kHz do 100 MHz","range":"od 2 mV do 10 mV","cmc":"2,8 %"},{"name":"100 kHz do 100 MHz","range":"od 10 mV do 10 V","cmc":"2,5 %"},{"name":"100 MHz do 200 MHz","range":"od 1 mV do 2 mV","cmc":"4,2 %"},{"name":"100 MHz do 200 MHz","range":"od 2 mV do 10 mV","cmc":"3,4 %"},{"name":"100 MHz do 200 MHz","range":"od 10 mV do 1 V","cmc":"3,0 %"},{"name":"100 MHz do 200 MHz","range":"od 1 V do 10 V","cmc":"4,2 %"},{"name":"200 MHz do 500 MHz","range":"od 1 mV do 2 mV","cmc":"4,5 %"},{"name":"200 MHz do 500 MHz","range":"od 2 mV do 10 mV","cmc":"3,7 %"},{"name":"200 MHz do 500 MHz","range":"od 10 mV do 1 V","cmc":"3,3 %"},{"name":"200 MHz do 500 MHz","range":"od 1 V do 10 V","cmc":"4,9 %"}],"parameters_en":[{"name":"100 kHz to 100 MHz","range":"1 mV to 2 mV","cmc":"3,6 %"},{"name":"100 kHz to 100 MHz","range":"2 mV to 10 mV","cmc":"2,8 %"},{"name":"100 kHz to 100 MHz","range":"10 mV to 10 V","cmc":"2,5 %"},{"name":"100 MHz to 200 MHz","range":"1 mV to 2 mV","cmc":"4,2 %"},{"name":"100 MHz to 200 MHz","range":"2 mV to 10 mV","cmc":"3,4 %"},{"name":"100 MHz to 200 MHz","range":"10 mV to 1 V","cmc":"3,0 %"},{"name":"100 MHz to 200 MHz","range":"1 V to 10 V","cmc":"4,2 %"},{"name":"200 MHz to 500 MHz","range":"1 mV to 2 mV","cmc":"4,5 %"},{"name":"200 MHz to 500 MHz","range":"2 mV to 10 mV","cmc":"3,7 %"},{"name":"200 MHz to 500 MHz","range":"10 mV to 1 V","cmc":"3,3 %"},{"name":"200 MHz to 500 MHz","range":"1 V to 10 V","cmc":"4,9 %"}],"parameters_zh":[{"name":"100 kHz 至 100 MHz","range":"1 mV 至 2 mV","cmc":"3,6 %"},{"name":"100 kHz 至 100 MHz","range":"2 mV 至 10 mV","cmc":"2,8 %"},{"name":"100 kHz 至 100 MHz","range":"10 mV 至 10 V","cmc":"2,5 %"},{"name":"100 MHz 至 200 MHz","range":"1 mV 至 2 mV","cmc":"4,2 %"},{"name":"100 MHz 至 200 MHz","range":"2 mV 至 10 mV","cmc":"3,4 %"},{"name":"100 MHz 至 200 MHz","range":"10 mV 至 1 V","cmc":"3,0 %"},{"name":"100 MHz 至 200 MHz","range":"1 V 至 10 V","cmc":"4,2 %"},{"name":"200 MHz 至 500 MHz","range":"1 mV 至 2 mV","cmc":"4,5 %"},{"name":"200 MHz 至 500 MHz","range":"2 mV 至 10 mV","cmc":"3,7 %"},{"name":"200 MHz 至 500 MHz","range":"10 mV 至 1 V","cmc":"3,3 %"},{"name":"200 MHz 至 500 MHz","range":"1 V 至 10 V","cmc":"4,9 %"}],"parameters_cs":[{"name":"100 kHz až 100 MHz","range":"1 mV až 2 mV","cmc":"3,6 %"},{"name":"100 kHz až 100 MHz","range":"2 mV až 10 mV","cmc":"2,8 %"},{"name":"100 kHz až 100 MHz","range":"10 mV až 10 V","cmc":"2,5 %"},{"name":"100 MHz až 200 MHz","range":"1 mV až 2 mV","cmc":"4,2 %"},{"name":"100 MHz až 200 MHz","range":"2 mV až 10 mV","cmc":"3,4 %"},{"name":"100 MHz až 200 MHz","range":"10 mV až 1 V","cmc":"3,0 %"},{"name":"100 MHz až 200 MHz","range":"1 V až 10 V","cmc":"4,2 %"},{"name":"200 MHz až 500 MHz","range":"1 mV až 2 mV","cmc":"4,5 %"},{"name":"200 MHz až 500 MHz","range":"2 mV až 10 mV","cmc":"3,7 %"},{"name":"200 MHz až 500 MHz","range":"10 mV až 1 V","cmc":"3,3 %"},{"name":"200 MHz až 500 MHz","range":"1 V až 10 V","cmc":"4,9 %"}],"technique":"Pomiar bezpośredni, porównanie z miliwoltomierzem w.cz. w płaszczyźnie złącza N 50 Ω","technique_en":"Direct measurement, comparison with a HF millivoltmeter in the plane of N connector of 50 Ω","technique_zh":"直接测量，在 50 Ω N 型连接器平面与高频毫伏表比较","technique_cs":"Přímé měření, porovnání s vf milivoltmetrem v rovině N konektoru 50 Ω","techniques":["Pomiar bezpośredni, porównanie z miliwoltomierzem w.cz. w płaszczyźnie złącza N 50 Ω"],"techniques_en":["Direct measurement, comparison with a HF millivoltmeter in the plane of N connector of 50 Ω"],"techniques_zh":["直接测量，在 50 Ω N 型连接器平面与高频毫伏表比较"],"techniques_cs":["Přímé měření, porovnání s vf milivoltmetrem v rovině N konektoru 50 Ω"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n100 kHz do 100 MHz od 1 mV do 2 mV CMC 3,6 %\n100 kHz do 100 MHz od 2 mV do 10 mV CMC 2,8 %\n100 kHz do 100 MHz od 10 mV do 10 V CMC 2,5 %\n100 MHz do 200 MHz od 1 mV do 2 mV CMC 4,2 %\n100 MHz do 200 MHz od 2 mV do 10 mV CMC 3,4 %\n100 MHz do 200 MHz od 10 mV do 1 V CMC 3,0 %\n100 MHz do 200 MHz od 1 V do 10 V CMC 4,2 %\n200 MHz do 500 MHz od 1 mV do 2 mV CMC 4,5 %\n200 MHz do 500 MHz od 2 mV do 10 mV CMC 3,7 %\n200 MHz do 500 MHz od 10 mV do 1 V CMC 3,3 %\n200 MHz do 500 MHz od 1 V do 10 V CMC 4,9 %\nPomiar bezpośredni, porównanie z miliwoltomierzem w.cz. w płaszczyźnie złącza N 50 Ω","reference":"MKE-UVF1","norm_bases":["MKE-UVF1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wartość skuteczna napięcia w.cz. / mierniki napięcia w.cz., oscyloskopy, miliwoltomierze w.cz., analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe Wzorcowanie – wielkości elektryczne Pomiar bezpośredni, porównanie z miliwoltomierzem w.cz. w płaszczyźnie złącza N 50 Ω 100 kHz do 100 MHz od 1 mV do 2 mV CMC 3,6 % 100 kHz do 100 MHz od 2 mV do 10 mV CMC 2,8 % 100 kHz do 100 MHz od 10 mV do 10 V CMC 2,5 % 100 MHz do 200 MHz od 1 mV do 2 mV CMC 4,2 % 100 MHz do 200 MHz od 2 mV do 10 mV CMC 3,4 % 100 MHz do 200 MHz od 10 mV do 1 V CMC 3,0 % 100 MHz do 200 MHz od 1 V do 10 V CMC 4,2 % 200 MHz do 500 MHz od 1 mV do 2 mV CMC 4,5 % 200 MHz do 500 MHz od 2 mV do 10 mV CMC 3,7 % 200 MHz do 500 MHz od 10 mV do 1 V CMC 3,3 % 200 MHz do 500 MHz od 1 V do 10 V CMC 4,9 % Efektivní hodnota vf napětí / Měřidla vf napětí, osciloskopy, vf milivoltmetry, frekvenční analyzátory, funkční generátory, signální generátory Kalibrace – elektrické veličiny Přímé měření, porovnání s vf milivoltmetrem v rovině N konektoru 50 Ω 100 kHz až 100 MHz 1 mV až 2 mV CMC 3,6 % 100 kHz až 100 MHz 2 mV až 10 mV CMC 2,8 % 100 kHz až 100 MHz 10 mV až 10 V CMC 2,5 % 100 MHz až 200 MHz 1 mV až 2 mV CMC 4,2 % 100 MHz až 200 MHz 2 mV až 10 mV CMC 3,4 % 100 MHz až 200 MHz 10 mV až 1 V CMC 3,0 % 100 MHz až 200 MHz 1 V až 10 V CMC 4,2 % 200 MHz až 500 MHz 1 mV až 2 mV CMC 4,5 % 200 MHz až 500 MHz 2 mV až 10 mV CMC 3,7 % 200 MHz až 500 MHz 10 mV až 1 V CMC 3,3 % 200 MHz až 500 MHz 1 V až 10 V CMC 4,9 % MKE-UVF1 Wartosc skuteczna napiecia w.cz. / mierniki napiecia w.cz., oscyloskopy, miliwoltomierze w.cz., analizatory czestotliwosci, generatory funkcyjne, generatory sygnalowe Wzorcowanie – wielkosci elektryczne Pomiar bezposredni, porownanie z miliwoltomierzem w.cz. w plaszczyznie zlacza N 50 Ω 100 kHz do 100 MHz od 1 mV do 2 mV CMC 3,6 % 100 kHz do 100 MHz od 2 mV do 10 mV CMC 2,8 % 100 kHz do 100 MHz od 10 mV do 10 V CMC 2,5 % 100 MHz do 200 MHz od 1 mV do 2 mV CMC 4,2 % 100 MHz do 200 MHz od 2 mV do 10 mV CMC 3,4 % 100 MHz do 200 MHz od 10 mV do 1 V CMC 3,0 % 100 MHz do 200 MHz od 1 V do 10 V CMC 4,2 % 200 MHz do 500 MHz od 1 mV do 2 mV CMC 4,5 % 200 MHz do 500 MHz od 2 mV do 10 mV CMC 3,7 % 200 MHz do 500 MHz od 10 mV do 1 V CMC 3,3 % 200 MHz do 500 MHz od 1 V do 10 V CMC 4,9 % Efektivni hodnota vf napeti / Meridla vf napeti, osciloskopy, vf milivoltmetry, frekvencni analyzatory, funkcni generatory, signalni generatory Kalibrace – elektricke veliciny Prime mereni, porovnani s vf milivoltmetrem v rovine N konektoru 50 Ω 100 kHz az 100 MHz 1 mV az 2 mV CMC 3,6 % 100 kHz az 100 MHz 2 mV az 10 mV CMC 2,8 % 100 kHz az 100 MHz 10 mV az 10 V CMC 2,5 % 100 MHz az 200 MHz 1 mV az 2 mV CMC 4,2 % 100 MHz az 200 MHz 2 mV az 10 mV CMC 3,4 % 100 MHz az 200 MHz 10 mV az 1 V CMC 3,0 % 100 MHz az 200 MHz 1 V az 10 V CMC 4,2 % 200 MHz az 500 MHz 1 mV az 2 mV CMC 4,5 % 200 MHz az 500 MHz 2 mV az 10 mV CMC 3,7 % 200 MHz az 500 MHz 10 mV az 1 V CMC 3,3 % 200 MHz az 500 MHz 1 V az 10 V CMC 4,9 % MKE-UVF1","search_en":"HF voltage effective value / HF voltage meters, oscilloscopes, HF millivoltmeters, frequency analyzers, function generators, signal generators Calibration – electrical quantities Direct measurement, comparison with a HF millivoltmeter in the plane of N connector of 50 Ω 100 kHz to 100 MHz 1 mV to 2 mV CMC 3,6 % 100 kHz to 100 MHz 2 mV to 10 mV CMC 2,8 % 100 kHz to 100 MHz 10 mV to 10 V CMC 2,5 % 100 MHz to 200 MHz 1 mV to 2 mV CMC 4,2 % 100 MHz to 200 MHz 2 mV to 10 mV CMC 3,4 % 100 MHz to 200 MHz 10 mV to 1 V CMC 3,0 % 100 MHz to 200 MHz 1 V to 10 V CMC 4,2 % 200 MHz to 500 MHz 1 mV to 2 mV CMC 4,5 % 200 MHz to 500 MHz 2 mV to 10 mV CMC 3,7 % 200 MHz to 500 MHz 10 mV to 1 V CMC 3,3 % 200 MHz to 500 MHz 1 V to 10 V CMC 4,9 % MKE-UVF1","search_zh":"高频电压有效值 / 高频电压测量仪器、示波器、高频毫伏表、频率分析仪、函数发生器、信号发生器 校准 – 电学量 直接测量，在 50 Ω N 型连接器平面与高频毫伏表比较 100 kHz 至 100 MHz 1 mV 至 2 mV CMC 3,6 % 100 kHz 至 100 MHz 2 mV 至 10 mV CMC 2,8 % 100 kHz 至 100 MHz 10 mV 至 10 V CMC 2,5 % 100 MHz 至 200 MHz 1 mV 至 2 mV CMC 4,2 % 100 MHz 至 200 MHz 2 mV 至 10 mV CMC 3,4 % 100 MHz 至 200 MHz 10 mV 至 1 V CMC 3,0 % 100 MHz 至 200 MHz 1 V 至 10 V CMC 4,2 % 200 MHz 至 500 MHz 1 mV 至 2 mV CMC 4,5 % 200 MHz 至 500 MHz 2 mV 至 10 mV CMC 3,7 % 200 MHz 至 500 MHz 10 mV 至 1 V CMC 3,3 % 200 MHz 至 500 MHz 1 V 至 10 V CMC 4,9 % MKE-UVF1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f23b2b5a7697c7c3ae9b2c70","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"22","test_object":"Wysokie napięcie stałe / zasilacze, mierniki do badań instalacji elektrycznych","test_object_en":"High DC voltage / Power supplies, inspection instruments","test_object_zh":"直流高压 / 电源、电气安装检测仪","test_object_cs":"Vysoké napětí stejnosměrné / Zdroje, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 kV do 100 kV","cmc":"0,20 %"}],"parameters_en":[{"name":"","range":"1 kV to 100 kV","cmc":"0,20 %"}],"parameters_zh":[{"name":"","range":"1 kV 至 100 kV","cmc":"0,20 %"}],"parameters_cs":[{"name":"","range":"1 kV až 100 kV","cmc":"0,20 %"}],"technique":"Pomiar bezpośredni z sondą wysokonapięciową","technique_en":"Direct measurement with a HV probe","technique_zh":"用高压探头直接测量","technique_cs":"Přímé měření s vn sondou","techniques":["Pomiar bezpośredni z sondą wysokonapięciową"],"techniques_en":["Direct measurement with a HV probe"],"techniques_zh":["用高压探头直接测量"],"techniques_cs":["Přímé měření s vn sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 kV do 100 kV CMC 0,20 %\nPomiar bezpośredni z sondą wysokonapięciową","reference":"MKE-UVNSS1, MKE-SRP.1","norm_bases":["MKE-UVNSS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokie napięcie stałe / zasilacze, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni z sondą wysokonapięciową od 1 kV do 100 kV CMC 0,20 % Vysoké napětí stejnosměrné / Zdroje, revizní přístroje Kalibrace – elektrické veličiny Přímé měření s vn sondou 1 kV až 100 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1 Wysokie napiecie stale / zasilacze, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni z sonda wysokonapieciowa od 1 kV do 100 kV CMC 0,20 % Vysoke napeti stejnosmerne / Zdroje, revizni pristroje Kalibrace – elektricke veliciny Prime mereni s vn sondou 1 kV az 100 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1","search_en":"High DC voltage / Power supplies, inspection instruments Calibration – electrical quantities Direct measurement with a HV probe 1 kV to 100 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1","search_zh":"直流高压 / 电源、电气安装检测仪 校准 – 电学量 用高压探头直接测量 1 kV 至 100 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"553e85cd004f3571c1677649","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"22","test_object":"Wysokie napięcie stałe / mierniki, mierniki do badań instalacji elektrycznych","test_object_en":"High DC voltage / Meters, inspection instruments","test_object_zh":"直流高压 / 测量仪器、电气安装检测仪","test_object_cs":"Vysoké napětí stejnosměrné / Měřidla, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 kV do 80 kV","cmc":"0,20 %"}],"parameters_en":[{"name":"","range":"1 kV to 80 kV","cmc":"0,20 %"}],"parameters_zh":[{"name":"","range":"1 kV 至 80 kV","cmc":"0,20 %"}],"parameters_cs":[{"name":"","range":"1 kV až 80 kV","cmc":"0,20 %"}],"technique":"Bezpośrednie generowanie, porównanie z sondą wysokonapięciową","technique_en":"Direct generation, comparison with a HV probe","technique_zh":"直接产生，与高压探头比较","technique_cs":"Přímé generování, porovnání s vn sondou","techniques":["Bezpośrednie generowanie, porównanie z sondą wysokonapięciową"],"techniques_en":["Direct generation, comparison with a HV probe"],"techniques_zh":["直接产生，与高压探头比较"],"techniques_cs":["Přímé generování, porovnání s vn sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 kV do 80 kV CMC 0,20 %\nBezpośrednie generowanie, porównanie z sondą wysokonapięciową","reference":"MKE-UVNSS1, MKE-SRP.1","norm_bases":["MKE-UVNSS1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokie napięcie stałe / mierniki, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie, porównanie z sondą wysokonapięciową od 1 kV do 80 kV CMC 0,20 % Vysoké napětí stejnosměrné / Měřidla, revizní přístroje Kalibrace – elektrické veličiny Přímé generování, porovnání s vn sondou 1 kV až 80 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1 Wysokie napiecie stale / mierniki, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie, porownanie z sonda wysokonapieciowa od 1 kV do 80 kV CMC 0,20 % Vysoke napeti stejnosmerne / Meridla, revizni pristroje Kalibrace – elektricke veliciny Prime generovani, porovnani s vn sondou 1 kV az 80 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1","search_en":"High DC voltage / Meters, inspection instruments Calibration – electrical quantities Direct generation, comparison with a HV probe 1 kV to 80 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1","search_zh":"直流高压 / 测量仪器、电气安装检测仪 校准 – 电学量 直接产生，与高压探头比较 1 kV 至 80 kV CMC 0,20 % MKE-UVNSS1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eea622ef564792408d861e6d","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"23","test_object":"Wysokie napięcie przemienne / mierniki, mierniki do badań instalacji elektrycznych","test_object_en":"High AC voltage / Meters, inspection instruments","test_object_zh":"交流高压 / 测量仪器、电气安装检测仪","test_object_cs":"Vysoké napětí střídavé / Měřidla, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 1 kV do 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"od 30 kV do 100 kV","cmc":"1,3 %"}],"parameters_en":[{"name":"50 Hz","range":"1 kV to 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"30 kV to 100 kV","cmc":"1,3 %"}],"parameters_zh":[{"name":"50 Hz","range":"1 kV 至 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"30 kV 至 100 kV","cmc":"1,3 %"}],"parameters_cs":[{"name":"50 Hz","range":"1 kV až 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"30 kV až 100 kV","cmc":"1,3 %"}],"technique":"Pomiar bezpośredni z sondą wysokonapięciową","technique_en":"Direct measurement with a HV probe","technique_zh":"用高压探头直接测量","technique_cs":"Přímé měření s vn sondou","techniques":["Pomiar bezpośredni z sondą wysokonapięciową"],"techniques_en":["Direct measurement with a HV probe"],"techniques_zh":["用高压探头直接测量"],"techniques_cs":["Přímé měření s vn sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz od 1 kV do 30 kV CMC 0,16 %\n50 Hz od 30 kV do 100 kV CMC 1,3 %\nPomiar bezpośredni z sondą wysokonapięciową","reference":"MKE-UVNST1, MKE-SRP.1","norm_bases":["MKE-UVNST1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokie napięcie przemienne / mierniki, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar bezpośredni z sondą wysokonapięciową 50 Hz od 1 kV do 30 kV CMC 0,16 % 50 Hz od 30 kV do 100 kV CMC 1,3 % Vysoké napětí střídavé / Měřidla, revizní přístroje Kalibrace – elektrické veličiny Přímé měření s vn sondou 50 Hz 1 kV až 30 kV CMC 0,16 % 50 Hz 30 kV až 100 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1 Wysokie napiecie przemienne / mierniki, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar bezposredni z sonda wysokonapieciowa 50 Hz od 1 kV do 30 kV CMC 0,16 % 50 Hz od 30 kV do 100 kV CMC 1,3 % Vysoke napeti stridave / Meridla, revizni pristroje Kalibrace – elektricke veliciny Prime mereni s vn sondou 50 Hz 1 kV az 30 kV CMC 0,16 % 50 Hz 30 kV az 100 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1","search_en":"High AC voltage / Meters, inspection instruments Calibration – electrical quantities Direct measurement with a HV probe 50 Hz 1 kV to 30 kV CMC 0,16 % 50 Hz 30 kV to 100 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1","search_zh":"交流高压 / 测量仪器、电气安装检测仪 校准 – 电学量 用高压探头直接测量 50 Hz 1 kV 至 30 kV CMC 0,16 % 50 Hz 30 kV 至 100 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c854bf35bd3485ea4470393","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"23","test_object":"Wysokie napięcie przemienne / zasilacze, mierniki do badań instalacji elektrycznych","test_object_en":"High AC voltage / Power supplies, inspection instruments","test_object_zh":"交流高压 / 电源、电气安装检测仪","test_object_cs":"Vysoké napětí střídavé / Zdroje, revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 1 kV do 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"od 30 kV do 50 kV","cmc":"1,3 %"}],"parameters_en":[{"name":"50 Hz","range":"1 kV to 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"30 kV to 50 kV","cmc":"1,3 %"}],"parameters_zh":[{"name":"50 Hz","range":"1 kV 至 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"30 kV 至 50 kV","cmc":"1,3 %"}],"parameters_cs":[{"name":"50 Hz","range":"1 kV až 30 kV","cmc":"0,16 %"},{"name":"50 Hz","range":"30 kV až 50 kV","cmc":"1,3 %"}],"technique":"Bezpośrednie generowanie, porównanie z sondą wysokonapięciową","technique_en":"Direct generation, comparison with a HV probe","technique_zh":"直接产生，与高压探头比较","technique_cs":"Přímé generování, porovnání s vn sondou","techniques":["Bezpośrednie generowanie, porównanie z sondą wysokonapięciową"],"techniques_en":["Direct generation, comparison with a HV probe"],"techniques_zh":["直接产生，与高压探头比较"],"techniques_cs":["Přímé generování, porovnání s vn sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n50 Hz od 1 kV do 30 kV CMC 0,16 %\n50 Hz od 30 kV do 50 kV CMC 1,3 %\nBezpośrednie generowanie, porównanie z sondą wysokonapięciową","reference":"MKE-UVNST1, MKE-SRP.1","norm_bases":["MKE-UVNST1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokie napięcie przemienne / zasilacze, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie, porównanie z sondą wysokonapięciową 50 Hz od 1 kV do 30 kV CMC 0,16 % 50 Hz od 30 kV do 50 kV CMC 1,3 % Vysoké napětí střídavé / Zdroje, revizní přístroje Kalibrace – elektrické veličiny Přímé generování, porovnání s vn sondou 50 Hz 1 kV až 30 kV CMC 0,16 % 50 Hz 30 kV až 50 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1 Wysokie napiecie przemienne / zasilacze, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie, porownanie z sonda wysokonapieciowa 50 Hz od 1 kV do 30 kV CMC 0,16 % 50 Hz od 30 kV do 50 kV CMC 1,3 % Vysoke napeti stridave / Zdroje, revizni pristroje Kalibrace – elektricke veliciny Prime generovani, porovnani s vn sondou 50 Hz 1 kV az 30 kV CMC 0,16 % 50 Hz 30 kV az 50 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1","search_en":"High AC voltage / Power supplies, inspection instruments Calibration – electrical quantities Direct generation, comparison with a HV probe 50 Hz 1 kV to 30 kV CMC 0,16 % 50 Hz 30 kV to 50 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1","search_zh":"交流高压 / 电源、电气安装检测仪 校准 – 电学量 直接产生，与高压探头比较 50 Hz 1 kV 至 30 kV CMC 0,16 % 50 Hz 30 kV 至 50 kV CMC 1,3 % MKE-UVNST1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ebfbd4caca774f38b4b38f19","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Natężenie oświetlenia / luksomierze","test_object_en":"Illuminance / Luxmeters","test_object_zh":"照度 / 照度计","test_object_cs":"Osvětlenost / Luxmetry","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 1 lx do 30000 lx","cmc":"2,5 %"}],"parameters_en":[{"name":"","range":"1 lx to 30000 lx","cmc":"2,5 %"}],"parameters_zh":[{"name":"","range":"1 lx 至 30000 lx","cmc":"2,5 %"}],"parameters_cs":[{"name":"","range":"1 lx až 30000 lx","cmc":"2,5 %"}],"technique":"Porównanie z luksomierzem","technique_en":"Comparison with a luxmeter","technique_zh":"与照度计比较","technique_cs":"Porovnání s luxmetrem","techniques":["Porównanie z luksomierzem"],"techniques_en":["Comparison with a luxmeter"],"techniques_zh":["与照度计比较"],"techniques_cs":["Porovnání s luxmetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nod 1 lx do 30000 lx CMC 2,5 %\nPorównanie z luksomierzem","reference":"MK-LUX1","norm_bases":["MK-LUX1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Natężenie oświetlenia / luksomierze Wzorcowanie – wielkości optyczne Porównanie z luksomierzem od 1 lx do 30000 lx CMC 2,5 % Osvětlenost / Luxmetry Kalibrace – optické veličiny Porovnání s luxmetrem 1 lx až 30000 lx CMC 2,5 % MK-LUX1 Natezenie oswietlenia / luksomierze Wzorcowanie – wielkosci optyczne Porownanie z luksomierzem od 1 lx do 30000 lx CMC 2,5 % Osvetlenost / Luxmetry Kalibrace – opticke veliciny Porovnani s luxmetrem 1 lx az 30000 lx CMC 2,5 % MK-LUX1","search_en":"Illuminance / Luxmeters Calibration – optical quantities Comparison with a luxmeter 1 lx to 30000 lx CMC 2,5 % MK-LUX1","search_zh":"照度 / 照度计 校准 – 光学量 与照度计比较 1 lx 至 30000 lx CMC 2,5 % MK-LUX1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fec6229eef4b2599de1b6e94","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory","test_object_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators","test_object_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器","test_object_cs":"Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"U ≥ 2,2 V TTL/50 Ω","range":"od 0,001 Hz do 50 MHz","cmc":"3,5·10⁻¹¹"},{"name":"U ≥ 1 V sinus / 50 Ω","range":"od 50 MHz do 1 GHz","cmc":"1,0·10⁻¹⁰"},{"name":"U ≥ 2 Všš / 50 Ω","range":"od 1 GHz do 3,2 GHz","cmc":"3,0·10⁻¹⁰"}],"parameters_en":[{"name":"U ≥ 2,2 V TTL/50 Ω","range":"0,001 Hz to 50 MHz","cmc":"3,5·10⁻¹¹"},{"name":"U ≥ 1 V sine / 50 Ω","range":"50 MHz to 1 GHz","cmc":"1,0·10⁻¹⁰"},{"name":"U ≥ 2 Všš / 50 Ω","range":"1 GHz to 3,2 GHz","cmc":"3,0·10⁻¹⁰"}],"parameters_zh":[{"name":"U ≥ 2,2 V TTL/50 Ω","range":"0,001 Hz 至 50 MHz","cmc":"3,5·10⁻¹¹"},{"name":"U ≥ 1 V 正弦 / 50 Ω","range":"50 MHz 至 1 GHz","cmc":"1,0·10⁻¹⁰"},{"name":"U ≥ 2 Všš / 50 Ω","range":"1 GHz 至 3,2 GHz","cmc":"3,0·10⁻¹⁰"}],"parameters_cs":[{"name":"U ≥ 2,2 V TTL/50 Ω","range":"0,001 Hz až 50 MHz","cmc":"3,5·10⁻¹¹"},{"name":"U ≥ 1 V sinus / 50 Ω","range":"50 MHz až 1 GHz","cmc":"1,0·10⁻¹⁰"},{"name":"U ≥ 2 Všš / 50 Ω","range":"1 GHz až 3,2 GHz","cmc":"3,0·10⁻¹⁰"}],"technique":"Bezpośrednie generowanie odbiornikiem GPS lub generatorem","technique_en":"Direct generation by a GPS receiver or generator","technique_zh":"用 GPS 接收机或发生器直接产生","technique_cs":"Přímé generování GPS přijímačem, nebo generátorem","techniques":["Bezpośrednie generowanie odbiornikiem GPS lub generatorem"],"techniques_en":["Direct generation by a GPS receiver or generator"],"techniques_zh":["用 GPS 接收机或发生器直接产生"],"techniques_cs":["Přímé generování GPS přijímačem, nebo generátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nU ≥ 2,2 V TTL/50 Ω od 0,001 Hz do 50 MHz CMC 3,5·10⁻¹¹\nU ≥ 1 V sinus / 50 Ω od 50 MHz do 1 GHz CMC 1,0·10⁻¹⁰\nU ≥ 2 Všš / 50 Ω od 1 GHz do 3,2 GHz CMC 3,0·10⁻¹⁰\nBezpośrednie generowanie odbiornikiem GPS lub generatorem","reference":"MKF-f1","norm_bases":["MKF-f1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkości czasu, częstotliwości Bezpośrednie generowanie odbiornikiem GPS lub generatorem U ≥ 2,2 V TTL/50 Ω od 0,001 Hz do 50 MHz CMC 3,5·10⁻¹¹ U ≥ 1 V sinus / 50 Ω od 50 MHz do 1 GHz CMC 1,0·10⁻¹⁰ U ≥ 2 Všš / 50 Ω od 1 GHz do 3,2 GHz CMC 3,0·10⁻¹⁰ Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory Kalibrace – veličiny času, frekvence Přímé generování GPS přijímačem, nebo generátorem U ≥ 2,2 V TTL/50 Ω 0,001 Hz až 50 MHz CMC 3,5·10⁻¹¹ U ≥ 1 V sinus / 50 Ω 50 MHz až 1 GHz CMC 1,0·10⁻¹⁰ U ≥ 2 Všš / 50 Ω 1 GHz až 3,2 GHz CMC 3,0·10⁻¹⁰ MKF-f1 Czestotliwosc / mierniki czestotliwosci, liczniki, analizatory czestotliwosci, generatory funkcyjne, generatory sygnalowe, wzorce czestotliwosci, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkosci czasu, czestotliwosci Bezposrednie generowanie odbiornikiem GPS lub generatorem U ≥ 2,2 V TTL/50 Ω od 0,001 Hz do 50 MHz CMC 3,5·10⁻¹¹ U ≥ 1 V sinus / 50 Ω od 50 MHz do 1 GHz CMC 1,0·10⁻¹⁰ U ≥ 2 Vss / 50 Ω od 1 GHz do 3,2 GHz CMC 3,0·10⁻¹⁰ Frekvence / Meridla frekvence, citace, frekvencni analyzatory, funkcni generatory, signalni generatory, frekvencni normaly, referencni oscilatory, multimetry, kalibratory Kalibrace – veliciny casu, frekvence Prime generovani GPS prijimacem, nebo generatorem U ≥ 2,2 V TTL/50 Ω 0,001 Hz az 50 MHz CMC 3,5·10⁻¹¹ U ≥ 1 V sinus / 50 Ω 50 MHz az 1 GHz CMC 1,0·10⁻¹⁰ U ≥ 2 Vss / 50 Ω 1 GHz az 3,2 GHz CMC 3,0·10⁻¹⁰ MKF-f1","search_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators Calibration – time and frequency quantities Direct generation by a GPS receiver or generator U ≥ 2,2 V TTL/50 Ω 0,001 Hz to 50 MHz CMC 3,5·10⁻¹¹ U ≥ 1 V sine / 50 Ω 50 MHz to 1 GHz CMC 1,0·10⁻¹⁰ U ≥ 2 Všš / 50 Ω 1 GHz to 3,2 GHz CMC 3,0·10⁻¹⁰ MKF-f1","search_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器 校准 – 时间、频率量 用 GPS 接收机或发生器直接产生 U ≥ 2,2 V TTL/50 Ω 0,001 Hz 至 50 MHz CMC 3,5·10⁻¹¹ U ≥ 1 V 正弦 / 50 Ω 50 MHz 至 1 GHz CMC 1,0·10⁻¹⁰ U ≥ 2 Všš / 50 Ω 1 GHz 至 3,2 GHz CMC 3,0·10⁻¹⁰ MKF-f1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0e53469bfd057a791f109fb","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory","test_object_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators","test_object_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器","test_object_cs":"Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s","range":"1 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s","range":"1 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s","range":"5 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s","range":"5 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s","range":"10 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s","range":"10 MHz","cmc":"6,0·10⁻¹²"}],"parameters_en":[{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 100 s to 200 s","range":"1 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 200 s to 2000 s","range":"1 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 100 s to 200 s","range":"5 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 200 s to 2000 s","range":"5 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 100 s to 200 s","range":"10 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 200 s to 2000 s","range":"10 MHz","cmc":"6,0·10⁻¹²"}],"parameters_zh":[{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 100 s 到 200 s","range":"1 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 200 s 到 2000 s","range":"1 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 100 s 到 200 s","range":"5 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 200 s 到 2000 s","range":"5 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 100 s 到 200 s","range":"10 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 200 s 到 2000 s","range":"10 MHz","cmc":"6,0·10⁻¹²"}],"parameters_cs":[{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 100 s do 200 s","range":"1 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 200 s do 2000 s","range":"1 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 100 s do 200 s","range":"5 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 200 s do 2000 s","range":"5 MHz","cmc":"6,0·10⁻¹²"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 100 s do 200 s","range":"10 MHz","cmc":"4,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 200 s do 2000 s","range":"10 MHz","cmc":"6,0·10⁻¹²"}],"technique":"Pomiar pośredni odbiornikiem GPS i licznikiem","technique_en":"Indirect measurement with a GPS receiver and counter","technique_zh":"用 GPS 接收机和计数器间接测量","technique_cs":"Nepřímé měření GPS přijímačem a čítačem","techniques":["Pomiar pośredni odbiornikiem GPS i licznikiem"],"techniques_en":["Indirect measurement with a GPS receiver and counter"],"techniques_zh":["用 GPS 接收机和计数器间接测量"],"techniques_cs":["Nepřímé měření GPS přijímačem a čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s 1 MHz CMC 4,0·10⁻¹¹\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s 1 MHz CMC 6,0·10⁻¹²\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s 5 MHz CMC 4,0·10⁻¹¹\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s 5 MHz CMC 6,0·10⁻¹²\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s 10 MHz CMC 4,0·10⁻¹¹\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s 10 MHz CMC 6,0·10⁻¹²\nPomiar pośredni odbiornikiem GPS i licznikiem","reference":"MKF-f1","norm_bases":["MKF-f1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkości czasu, częstotliwości Pomiar pośredni odbiornikiem GPS i licznikiem Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s 1 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s 1 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s 5 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s 5 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 100 s do 200 s 10 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ od 200 s do 2000 s 10 MHz CMC 6,0·10⁻¹² Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory Kalibrace – veličiny času, frekvence Nepřímé měření GPS přijímačem a čítačem Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 100 s do 200 s 1 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 200 s do 2000 s 1 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 100 s do 200 s 5 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 200 s do 2000 s 5 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 100 s do 200 s 10 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ od 200 s do 2000 s 10 MHz CMC 6,0·10⁻¹² MKF-f1 Czestotliwosc / mierniki czestotliwosci, liczniki, analizatory czestotliwosci, generatory funkcyjne, generatory sygnalowe, wzorce czestotliwosci, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkosci czasu, czestotliwosci Pomiar posredni odbiornikiem GPS i licznikiem Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ od 100 s do 200 s 1 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ od 200 s do 2000 s 1 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ od 100 s do 200 s 5 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ od 200 s do 2000 s 5 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ od 100 s do 200 s 10 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ od 200 s do 2000 s 10 MHz CMC 6,0·10⁻¹² Frekvence / Meridla frekvence, citace, frekvencni analyzatory, funkcni generatory, signalni generatory, frekvencni normaly, referencni oscilatory, multimetry, kalibratory Kalibrace – veliciny casu, frekvence Neprime mereni GPS prijimacem a citacem Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ od 100 s do 200 s 1 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ od 200 s do 2000 s 1 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ od 100 s do 200 s 5 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ od 200 s do 2000 s 5 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ od 100 s do 200 s 10 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ od 200 s do 2000 s 10 MHz CMC 6,0·10⁻¹² MKF-f1","search_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators Calibration – time and frequency quantities Indirect measurement with a GPS receiver and counter Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 100 s to 200 s 1 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 200 s to 2000 s 1 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 100 s to 200 s 5 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 200 s to 2000 s 5 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 100 s to 200 s 10 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ from 200 s to 2000 s 10 MHz CMC 6,0·10⁻¹² MKF-f1","search_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器 校准 – 时间、频率量 用 GPS 接收机和计数器间接测量 Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 100 s 到 200 s 1 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 200 s 到 2000 s 1 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 100 s 到 200 s 5 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 200 s 到 2000 s 5 MHz CMC 6,0·10⁻¹² Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 100 s 到 200 s 10 MHz CMC 4,0·10⁻¹¹ Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 从 200 s 到 2000 s 10 MHz CMC 6,0·10⁻¹² MKF-f1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed7d8bc1913bc0271ebfb787","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory","test_object_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators","test_object_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器","test_object_cs":"Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"sygnały impulsowe; τ większe niż 10 s","range":"od 0,001 Hz do 100 Hz","cmc":"8,0·10⁻¹¹"},{"name":"sygnały impulsowe; τ większe niż 1 s","range":"od 100 Hz do 350 MHz","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ większe niż 10 s","range":"od 1 Hz do 30 Hz","cmc":"5·10⁻⁵ Hz"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ większe niż 1 s","range":"od 30 Hz do 300 Hz","cmc":"3·10⁻⁴ Hz"},{"name":"Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB","range":"od 300 Hz do 100 kHz","cmc":"5·10⁻⁵ Hz"}],"parameters_en":[{"name":"pulse signals; τ over 10 s","range":"0,001 Hz to 100 Hz","cmc":"8,0·10⁻¹¹"},{"name":"pulse signals; τ over 1 s","range":"100 Hz to 350 MHz","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ over 10 s","range":"1 Hz to 30 Hz","cmc":"5·10⁻⁵ Hz"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ over 1 s","range":"30 Hz to 300 Hz","cmc":"3·10⁻⁴ Hz"},{"name":"Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB","range":"300 Hz to 100 kHz","cmc":"5·10⁻⁵ Hz"}],"parameters_zh":[{"name":"脉冲信号；τ 大于 10 s","range":"0,001 Hz 至 100 Hz","cmc":"8,0·10⁻¹¹"},{"name":"脉冲信号；τ 大于 1 s","range":"100 Hz 至 350 MHz","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 大于 10 s","range":"1 Hz 至 30 Hz","cmc":"5·10⁻⁵ Hz"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 大于 1 s","range":"30 Hz 至 300 Hz","cmc":"3·10⁻⁴ Hz"},{"name":"Uvst ≥ 1 Vef，信噪比 ≥ 60 dB","range":"300 Hz 至 100 kHz","cmc":"5·10⁻⁵ Hz"}],"parameters_cs":[{"name":"impulsní signály; τ větší než 10 s","range":"0,001 Hz až 100 Hz","cmc":"8,0·10⁻¹¹"},{"name":"impulsní signály; τ větší než1 s","range":"100 Hz až 350 MHz","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ větší než 10 s","range":"1 Hz až 30 Hz","cmc":"5·10⁻⁵ Hz"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ větší než1 s","range":"30 Hz až 300 Hz","cmc":"3·10⁻⁴ Hz"},{"name":"Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB","range":"300 Hz až 100 kHz","cmc":"5·10⁻⁵ Hz"}],"technique":"Pomiar bezpośredni licznikiem","technique_en":"Direct measurement by a counter","technique_zh":"用计数器直接测量","technique_cs":"Přímé měření čítačem","techniques":["Pomiar bezpośredni licznikiem"],"techniques_en":["Direct measurement by a counter"],"techniques_zh":["用计数器直接测量"],"techniques_cs":["Přímé měření čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nsygnały impulsowe; τ większe niż 10 s od 0,001 Hz do 100 Hz CMC 8,0·10⁻¹¹\nsygnały impulsowe; τ większe niż 1 s od 100 Hz do 350 MHz CMC 8,0·10⁻¹¹\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ większe niż 10 s od 1 Hz do 30 Hz CMC 5·10⁻⁵ Hz\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ większe niż 1 s od 30 Hz do 300 Hz CMC 3·10⁻⁴ Hz\nUvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB od 300 Hz do 100 kHz CMC 5·10⁻⁵ Hz\nPomiar bezpośredni licznikiem","reference":"MKF-f1, MKE-SRP.1","norm_bases":["MKF-f1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkości czasu, częstotliwości Pomiar bezpośredni licznikiem sygnały impulsowe; τ większe niż 10 s od 0,001 Hz do 100 Hz CMC 8,0·10⁻¹¹ sygnały impulsowe; τ większe niż 1 s od 100 Hz do 350 MHz CMC 8,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ większe niż 10 s od 1 Hz do 30 Hz CMC 5·10⁻⁵ Hz Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB; τ większe niż 1 s od 30 Hz do 300 Hz CMC 3·10⁻⁴ Hz Uvst ≥ 1 Vef, stosunek sygnał / szum ≥ 60 dB od 300 Hz do 100 kHz CMC 5·10⁻⁵ Hz Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory Kalibrace – veličiny času, frekvence Přímé měření čítačem impulsní signály; τ větší než 10 s 0,001 Hz až 100 Hz CMC 8,0·10⁻¹¹ impulsní signály; τ větší než1 s 100 Hz až 350 MHz CMC 8,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ větší než 10 s 1 Hz až 30 Hz CMC 5·10⁻⁵ Hz Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB; τ větší než1 s 30 Hz až 300 Hz CMC 3·10⁻⁴ Hz Uvst ≥ 1 Vef, odstup signál / šum ≥ 60 dB 300 Hz až 100 kHz CMC 5·10⁻⁵ Hz MKF-f1, MKE-SRP.1 Czestotliwosc / mierniki czestotliwosci, liczniki, analizatory czestotliwosci, generatory funkcyjne, generatory sygnalowe, wzorce czestotliwosci, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkosci czasu, czestotliwosci Pomiar bezposredni licznikiem sygnaly impulsowe; τ wieksze niz 10 s od 0,001 Hz do 100 Hz CMC 8,0·10⁻¹¹ sygnaly impulsowe; τ wieksze niz 1 s od 100 Hz do 350 MHz CMC 8,0·10⁻¹¹ Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ wieksze niz 10 s od 1 Hz do 30 Hz CMC 5·10⁻⁵ Hz Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB; τ wieksze niz 1 s od 30 Hz do 300 Hz CMC 3·10⁻⁴ Hz Uvst ≥ 1 Vef, stosunek sygnal / szum ≥ 60 dB od 300 Hz do 100 kHz CMC 5·10⁻⁵ Hz Frekvence / Meridla frekvence, citace, frekvencni analyzatory, funkcni generatory, signalni generatory, frekvencni normaly, referencni oscilatory, multimetry, kalibratory Kalibrace – veliciny casu, frekvence Prime mereni citacem impulsni signaly; τ vetsi nez 10 s 0,001 Hz az 100 Hz CMC 8,0·10⁻¹¹ impulsni signaly; τ vetsi nez1 s 100 Hz az 350 MHz CMC 8,0·10⁻¹¹ Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ vetsi nez 10 s 1 Hz az 30 Hz CMC 5·10⁻⁵ Hz Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB; τ vetsi nez1 s 30 Hz az 300 Hz CMC 3·10⁻⁴ Hz Uvst ≥ 1 Vef, odstup signal / sum ≥ 60 dB 300 Hz az 100 kHz CMC 5·10⁻⁵ Hz MKF-f1, MKE-SRP.1","search_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators Calibration – time and frequency quantities Direct measurement by a counter pulse signals; τ over 10 s 0,001 Hz to 100 Hz CMC 8,0·10⁻¹¹ pulse signals; τ over 1 s 100 Hz to 350 MHz CMC 8,0·10⁻¹¹ Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ over 10 s 1 Hz to 30 Hz CMC 5·10⁻⁵ Hz Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB; τ over 1 s 30 Hz to 300 Hz CMC 3·10⁻⁴ Hz Uvst ≥ 1 Vef, signal to noise ratio ≥ 60 dB 300 Hz to 100 kHz CMC 5·10⁻⁵ Hz MKF-f1, MKE-SRP.1","search_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器 校准 – 时间、频率量 用计数器直接测量 脉冲信号；τ 大于 10 s 0,001 Hz 至 100 Hz CMC 8,0·10⁻¹¹ 脉冲信号；τ 大于 1 s 100 Hz 至 350 MHz CMC 8,0·10⁻¹¹ Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 大于 10 s 1 Hz 至 30 Hz CMC 5·10⁻⁵ Hz Uvst ≥ 1 Vef，信噪比 ≥ 60 dB；τ 大于 1 s 30 Hz 至 300 Hz CMC 3·10⁻⁴ Hz Uvst ≥ 1 Vef，信噪比 ≥ 60 dB 300 Hz 至 100 kHz CMC 5·10⁻⁵ Hz MKF-f1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04bac85f3f398a6e6ffc6e3a","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory","test_object_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators","test_object_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器","test_object_cs":"Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"","range":"od 100 kHz do 300 kHz","cmc":"4,0·10⁻¹⁰"},{"name":"","range":"od 300 kHz do 600 kHz","cmc":"2,0·10⁻¹⁰"},{"name":"","range":"od 600 kHz do 6 GHz","cmc":"1,0·10⁻¹⁰"}],"parameters_en":[{"name":"","range":"100 kHz to 300 kHz","cmc":"4,0·10⁻¹⁰"},{"name":"","range":"300 kHz to 600 kHz","cmc":"2,0·10⁻¹⁰"},{"name":"","range":"600 kHz to 6 GHz","cmc":"1,0·10⁻¹⁰"}],"parameters_zh":[{"name":"","range":"100 kHz 至 300 kHz","cmc":"4,0·10⁻¹⁰"},{"name":"","range":"300 kHz 至 600 kHz","cmc":"2,0·10⁻¹⁰"},{"name":"","range":"600 kHz 至 6 GHz","cmc":"1,0·10⁻¹⁰"}],"parameters_cs":[{"name":"","range":"100 kHz až 300 kHz","cmc":"4,0·10⁻¹⁰"},{"name":"","range":"300 kHz až 600 kHz","cmc":"2,0·10⁻¹⁰"},{"name":"","range":"600 kHz až 6 GHz","cmc":"1,0·10⁻¹⁰"}],"technique":"Pomiar bezpośredni licznikiem","technique_en":"Direct measurement by a counter","technique_zh":"用计数器直接测量","technique_cs":"Přímé měření čítačem","techniques":["Pomiar bezpośredni licznikiem"],"techniques_en":["Direct measurement by a counter"],"techniques_zh":["用计数器直接测量"],"techniques_cs":["Přímé měření čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nod 100 kHz do 300 kHz CMC 4,0·10⁻¹⁰\nod 300 kHz do 600 kHz CMC 2,0·10⁻¹⁰\nod 600 kHz do 6 GHz CMC 1,0·10⁻¹⁰\nPomiar bezpośredni licznikiem","reference":"MKF-f1","norm_bases":["MKF-f1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości, liczniki, analizatory częstotliwości, generatory funkcyjne, generatory sygnałowe, wzorce częstotliwości, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkości czasu, częstotliwości Pomiar bezpośredni licznikiem od 100 kHz do 300 kHz CMC 4,0·10⁻¹⁰ od 300 kHz do 600 kHz CMC 2,0·10⁻¹⁰ od 600 kHz do 6 GHz CMC 1,0·10⁻¹⁰ Frekvence / Měřidla frekvence, čítače, frekvenční analyzátory, funkční generátory, signální generátory, frekvenční normály, referenční oscilátory, multimetry, kalibrátory Kalibrace – veličiny času, frekvence Přímé měření čítačem 100 kHz až 300 kHz CMC 4,0·10⁻¹⁰ 300 kHz až 600 kHz CMC 2,0·10⁻¹⁰ 600 kHz až 6 GHz CMC 1,0·10⁻¹⁰ MKF-f1 Czestotliwosc / mierniki czestotliwosci, liczniki, analizatory czestotliwosci, generatory funkcyjne, generatory sygnalowe, wzorce czestotliwosci, oscylatory odniesienia, multimetry, kalibratory Wzorcowanie – wielkosci czasu, czestotliwosci Pomiar bezposredni licznikiem od 100 kHz do 300 kHz CMC 4,0·10⁻¹⁰ od 300 kHz do 600 kHz CMC 2,0·10⁻¹⁰ od 600 kHz do 6 GHz CMC 1,0·10⁻¹⁰ Frekvence / Meridla frekvence, citace, frekvencni analyzatory, funkcni generatory, signalni generatory, frekvencni normaly, referencni oscilatory, multimetry, kalibratory Kalibrace – veliciny casu, frekvence Prime mereni citacem 100 kHz az 300 kHz CMC 4,0·10⁻¹⁰ 300 kHz az 600 kHz CMC 2,0·10⁻¹⁰ 600 kHz az 6 GHz CMC 1,0·10⁻¹⁰ MKF-f1","search_en":"Frequency / Frequency meters, counters, frequency analyzers, function generators, signal generators, frequency references, reference oscillators, multimeters, calibrators Calibration – time and frequency quantities Direct measurement by a counter 100 kHz to 300 kHz CMC 4,0·10⁻¹⁰ 300 kHz to 600 kHz CMC 2,0·10⁻¹⁰ 600 kHz to 6 GHz CMC 1,0·10⁻¹⁰ MKF-f1","search_zh":"频率 / 频率测量仪器、计数器、频率分析仪、函数发生器、信号发生器、频率基准、参考振荡器、万用表、校准器 校准 – 时间、频率量 用计数器直接测量 100 kHz 至 300 kHz CMC 4,0·10⁻¹⁰ 300 kHz 至 600 kHz CMC 2,0·10⁻¹⁰ 600 kHz 至 6 GHz CMC 1,0·10⁻¹⁰ MKF-f1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"02f6bc9c339d2a704796c4a3","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"2","test_object":"Przedział czasu / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych","test_object_en":"Time interval / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments","test_object_zh":"时间间隔 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪","test_object_cs":"Časový interval / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"Ušš ≥ 1 V; 50 Ω","range":"od 1 ns do 4 ns","cmc":"0,70 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"od 4 ns do 10 ns","cmc":"4,5 % + 0,5 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"od 10 ns do 100 ns","cmc":"5,5 % + 0,5 ns"}],"parameters_en":[{"name":"Ušš ≥ 1 V; 50 Ω","range":"1 ns to 4 ns","cmc":"0,70 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"4 ns to 10 ns","cmc":"4,5 % + 0,5 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"10 ns to 100 ns","cmc":"5,5 % + 0,5 ns"}],"parameters_zh":[{"name":"Ušš ≥ 1 V; 50 Ω","range":"1 ns 至 4 ns","cmc":"0,70 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"4 ns 至 10 ns","cmc":"4,5 % + 0,5 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"10 ns 至 100 ns","cmc":"5,5 % + 0,5 ns"}],"parameters_cs":[{"name":"Ušš ≥ 1 V; 50 Ω","range":"1 ns až 4 ns","cmc":"0,70 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"4 ns až 10 ns","cmc":"4,5 % + 0,5 ns"},{"name":"Ušš ≥ 1 V; 50 Ω","range":"10 ns až 100 ns","cmc":"5,5 % + 0,5 ns"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nUšš ≥ 1 V; 50 Ω od 1 ns do 4 ns CMC 0,70 ns\nUšš ≥ 1 V; 50 Ω od 4 ns do 10 ns CMC 4,5 % + 0,5 ns\nUšš ≥ 1 V; 50 Ω od 10 ns do 100 ns CMC 5,5 % + 0,5 ns\nBezpośrednie generowanie kalibratorem","reference":"MKF-t1","norm_bases":["MKF-t1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości czasu, częstotliwości Bezpośrednie generowanie kalibratorem Ušš ≥ 1 V; 50 Ω od 1 ns do 4 ns CMC 0,70 ns Ušš ≥ 1 V; 50 Ω od 4 ns do 10 ns CMC 4,5 % + 0,5 ns Ušš ≥ 1 V; 50 Ω od 10 ns do 100 ns CMC 5,5 % + 0,5 ns Časový interval / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje Kalibrace – veličiny času, frekvence Přímé generování kalibrátorem Ušš ≥ 1 V; 50 Ω 1 ns až 4 ns CMC 0,70 ns Ušš ≥ 1 V; 50 Ω 4 ns až 10 ns CMC 4,5 % + 0,5 ns Ušš ≥ 1 V; 50 Ω 10 ns až 100 ns CMC 5,5 % + 0,5 ns MKF-t1 Przedzial czasu / mierniki przedzialow czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsow, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu, czestotliwosci Bezposrednie generowanie kalibratorem Uss ≥ 1 V; 50 Ω od 1 ns do 4 ns CMC 0,70 ns Uss ≥ 1 V; 50 Ω od 4 ns do 10 ns CMC 4,5 % + 0,5 ns Uss ≥ 1 V; 50 Ω od 10 ns do 100 ns CMC 5,5 % + 0,5 ns Casovy interval / Meridla casoveho intervalu, citace, osciloskopy, funkcni generatory, impulzni generatory, digitalni a mechanicke stopky, casovace, revizni pristroje Kalibrace – veliciny casu, frekvence Prime generovani kalibratorem Uss ≥ 1 V; 50 Ω 1 ns az 4 ns CMC 0,70 ns Uss ≥ 1 V; 50 Ω 4 ns az 10 ns CMC 4,5 % + 0,5 ns Uss ≥ 1 V; 50 Ω 10 ns az 100 ns CMC 5,5 % + 0,5 ns MKF-t1","search_en":"Time interval / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments Calibration – time and frequency quantities Direct generation with a calibrator Ušš ≥ 1 V; 50 Ω 1 ns to 4 ns CMC 0,70 ns Ušš ≥ 1 V; 50 Ω 4 ns to 10 ns CMC 4,5 % + 0,5 ns Ušš ≥ 1 V; 50 Ω 10 ns to 100 ns CMC 5,5 % + 0,5 ns MKF-t1","search_zh":"时间间隔 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪 校准 – 时间、频率量 用校准器直接产生 Ušš ≥ 1 V; 50 Ω 1 ns 至 4 ns CMC 0,70 ns Ušš ≥ 1 V; 50 Ω 4 ns 至 10 ns CMC 4,5 % + 0,5 ns Ušš ≥ 1 V; 50 Ω 10 ns 至 100 ns CMC 5,5 % + 0,5 ns MKF-t1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c050f31a600d3e07c4dd0f6","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"2","test_object":"Przedział czasu / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych","test_object_en":"Time interval / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments","test_object_zh":"时间间隔 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪","test_object_cs":"Časový interval / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"od 100 ns do 1 µs","cmc":"2,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"od 1 µs do 100 s","cmc":"4,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"od 100 s do 10⁵ s","cmc":"3,5·10⁻¹¹"}],"parameters_en":[{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"100 ns to 1 µs","cmc":"2,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"1 µs to 100 s","cmc":"4,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"100 s to 10⁵ s","cmc":"3,5·10⁻¹¹"}],"parameters_zh":[{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"100 ns 至 1 µs","cmc":"2,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"1 µs 至 100 s","cmc":"4,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"100 s 至 10⁵ s","cmc":"3,5·10⁻¹¹"}],"parameters_cs":[{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"100 ns až 1 µs","cmc":"2,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"1 µs až 100 s","cmc":"4,0 ns"},{"name":"U ≥ 2,2 V TTL; 50 Ω","range":"100 s až 10⁵ s","cmc":"3,5·10⁻¹¹"}],"technique":"Bezpośrednie generowanie odbiornikiem GPS","technique_en":"Direct generation by a GPS receiver","technique_zh":"用 GPS 接收机直接产生","technique_cs":"Přímé generování GPS přijímačem","techniques":["Bezpośrednie generowanie odbiornikiem GPS"],"techniques_en":["Direct generation by a GPS receiver"],"techniques_zh":["用 GPS 接收机直接产生"],"techniques_cs":["Přímé generování GPS přijímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nU ≥ 2,2 V TTL; 50 Ω od 100 ns do 1 µs CMC 2,0 ns\nU ≥ 2,2 V TTL; 50 Ω od 1 µs do 100 s CMC 4,0 ns\nU ≥ 2,2 V TTL; 50 Ω od 100 s do 10⁵ s CMC 3,5·10⁻¹¹\nBezpośrednie generowanie odbiornikiem GPS","reference":"MKF-t1","norm_bases":["MKF-t1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przedział czasu / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości czasu, częstotliwości Bezpośrednie generowanie odbiornikiem GPS U ≥ 2,2 V TTL; 50 Ω od 100 ns do 1 µs CMC 2,0 ns U ≥ 2,2 V TTL; 50 Ω od 1 µs do 100 s CMC 4,0 ns U ≥ 2,2 V TTL; 50 Ω od 100 s do 10⁵ s CMC 3,5·10⁻¹¹ Časový interval / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje Kalibrace – veličiny času, frekvence Přímé generování GPS přijímačem U ≥ 2,2 V TTL; 50 Ω 100 ns až 1 µs CMC 2,0 ns U ≥ 2,2 V TTL; 50 Ω 1 µs až 100 s CMC 4,0 ns U ≥ 2,2 V TTL; 50 Ω 100 s až 10⁵ s CMC 3,5·10⁻¹¹ MKF-t1 Przedzial czasu / mierniki przedzialow czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsow, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu, czestotliwosci Bezposrednie generowanie odbiornikiem GPS U ≥ 2,2 V TTL; 50 Ω od 100 ns do 1 µs CMC 2,0 ns U ≥ 2,2 V TTL; 50 Ω od 1 µs do 100 s CMC 4,0 ns U ≥ 2,2 V TTL; 50 Ω od 100 s do 10⁵ s CMC 3,5·10⁻¹¹ Casovy interval / Meridla casoveho intervalu, citace, osciloskopy, funkcni generatory, impulzni generatory, digitalni a mechanicke stopky, casovace, revizni pristroje Kalibrace – veliciny casu, frekvence Prime generovani GPS prijimacem U ≥ 2,2 V TTL; 50 Ω 100 ns az 1 µs CMC 2,0 ns U ≥ 2,2 V TTL; 50 Ω 1 µs az 100 s CMC 4,0 ns U ≥ 2,2 V TTL; 50 Ω 100 s az 10⁵ s CMC 3,5·10⁻¹¹ MKF-t1","search_en":"Time interval / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments Calibration – time and frequency quantities Direct generation by a GPS receiver U ≥ 2,2 V TTL; 50 Ω 100 ns to 1 µs CMC 2,0 ns U ≥ 2,2 V TTL; 50 Ω 1 µs to 100 s CMC 4,0 ns U ≥ 2,2 V TTL; 50 Ω 100 s to 10⁵ s CMC 3,5·10⁻¹¹ MKF-t1","search_zh":"时间间隔 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪 校准 – 时间、频率量 用 GPS 接收机直接产生 U ≥ 2,2 V TTL; 50 Ω 100 ns 至 1 µs CMC 2,0 ns U ≥ 2,2 V TTL; 50 Ω 1 µs 至 100 s CMC 4,0 ns U ≥ 2,2 V TTL; 50 Ω 100 s 至 10⁵ s CMC 3,5·10⁻¹¹ MKF-t1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ebc594913e61961836db94e7","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"3","test_object":"Okres sygnałów impulsowych / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych","test_object_en":"Pulse signal period / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments","test_object_zh":"脉冲信号周期 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪","test_object_cs":"Perioda impulsních signálů / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"Uvst ≥ 1 V; τ większe niż 10 s","range":"od 2,85 ns do 10 ms","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 V; τ większe niż 1 s","range":"od 10 ms do 1000 s","cmc":"8,0·10⁻¹¹"}],"parameters_en":[{"name":"Uvst ≥ 1 V; τ over 10 s","range":"2,85 ns to 10 ms","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 V; τ over 1 s","range":"10 ms to 1000 s","cmc":"8,0·10⁻¹¹"}],"parameters_zh":[{"name":"Uvst ≥ 1 V；τ 大于 10 s","range":"2,85 ns 至 10 ms","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 V；τ 大于 1 s","range":"10 ms 至 1000 s","cmc":"8,0·10⁻¹¹"}],"parameters_cs":[{"name":"Uvst ≥ 1 V; τ větší než 10 s","range":"2,85 ns až 10 ms","cmc":"8,0·10⁻¹¹"},{"name":"Uvst ≥ 1 V; τ větší než1 s","range":"10 ms až 1000 s","cmc":"8,0·10⁻¹¹"}],"technique":"Pomiar bezpośredni licznikiem","technique_en":"Direct measurement by a counter","technique_zh":"用计数器直接测量","technique_cs":"Přímé měření čítačem","techniques":["Pomiar bezpośredni licznikiem"],"techniques_en":["Direct measurement by a counter"],"techniques_zh":["用计数器直接测量"],"techniques_cs":["Přímé měření čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nUvst ≥ 1 V; τ większe niż 10 s od 2,85 ns do 10 ms CMC 8,0·10⁻¹¹\nUvst ≥ 1 V; τ większe niż 1 s od 10 ms do 1000 s CMC 8,0·10⁻¹¹\nPomiar bezpośredni licznikiem","reference":"MKF-t1","norm_bases":["MKF-t1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Okres sygnałów impulsowych / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości czasu, częstotliwości Pomiar bezpośredni licznikiem Uvst ≥ 1 V; τ większe niż 10 s od 2,85 ns do 10 ms CMC 8,0·10⁻¹¹ Uvst ≥ 1 V; τ większe niż 1 s od 10 ms do 1000 s CMC 8,0·10⁻¹¹ Perioda impulsních signálů / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje Kalibrace – veličiny času, frekvence Přímé měření čítačem Uvst ≥ 1 V; τ větší než 10 s 2,85 ns až 10 ms CMC 8,0·10⁻¹¹ Uvst ≥ 1 V; τ větší než1 s 10 ms až 1000 s CMC 8,0·10⁻¹¹ MKF-t1 Okres sygnalow impulsowych / mierniki przedzialow czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsow, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu, czestotliwosci Pomiar bezposredni licznikiem Uvst ≥ 1 V; τ wieksze niz 10 s od 2,85 ns do 10 ms CMC 8,0·10⁻¹¹ Uvst ≥ 1 V; τ wieksze niz 1 s od 10 ms do 1000 s CMC 8,0·10⁻¹¹ Perioda impulsnich signalu / Meridla casoveho intervalu, citace, osciloskopy, funkcni generatory, impulzni generatory, digitalni a mechanicke stopky, casovace, revizni pristroje Kalibrace – veliciny casu, frekvence Prime mereni citacem Uvst ≥ 1 V; τ vetsi nez 10 s 2,85 ns az 10 ms CMC 8,0·10⁻¹¹ Uvst ≥ 1 V; τ vetsi nez1 s 10 ms az 1000 s CMC 8,0·10⁻¹¹ MKF-t1","search_en":"Pulse signal period / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments Calibration – time and frequency quantities Direct measurement by a counter Uvst ≥ 1 V; τ over 10 s 2,85 ns to 10 ms CMC 8,0·10⁻¹¹ Uvst ≥ 1 V; τ over 1 s 10 ms to 1000 s CMC 8,0·10⁻¹¹ MKF-t1","search_zh":"脉冲信号周期 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪 校准 – 时间、频率量 用计数器直接测量 Uvst ≥ 1 V；τ 大于 10 s 2,85 ns 至 10 ms CMC 8,0·10⁻¹¹ Uvst ≥ 1 V；τ 大于 1 s 10 ms 至 1000 s CMC 8,0·10⁻¹¹ MKF-t1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b43c79bcd2e14d425fdfdc0","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"4","test_object":"Czas trwania sygnałów impulsowych / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych","test_object_en":"Pulse signal duration / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments","test_object_zh":"脉冲信号持续时间 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪","test_object_cs":"Délka trvání impulsních signálů / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"Uvst ≥ 1 V","range":"od 5 ns do 10 s","cmc":"1,0 ns"},{"name":"Uvst ≥ 1 V","range":"od 10 s do 10⁵ s","cmc":"8,0·10⁻¹¹"}],"parameters_en":[{"name":"Uvst ≥ 1 V","range":"5 ns to 10 s","cmc":"1,0 ns"},{"name":"Uvst ≥ 1 V","range":"10 s to 10⁵ s","cmc":"8,0·10⁻¹¹"}],"parameters_zh":[{"name":"Uvst ≥ 1 V","range":"5 ns 至 10 s","cmc":"1,0 ns"},{"name":"Uvst ≥ 1 V","range":"10 s 至 10⁵ s","cmc":"8,0·10⁻¹¹"}],"parameters_cs":[{"name":"Uvst ≥ 1 V","range":"5 ns až 10 s","cmc":"1,0 ns"},{"name":"Uvst ≥ 1 V","range":"10 s až 10⁵ s","cmc":"8,0·10⁻¹¹"}],"technique":"Pomiar bezpośredni licznikiem","technique_en":"Direct measurement by a counter","technique_zh":"用计数器直接测量","technique_cs":"Přímé měření čítačem","techniques":["Pomiar bezpośredni licznikiem"],"techniques_en":["Direct measurement by a counter"],"techniques_zh":["用计数器直接测量"],"techniques_cs":["Přímé měření čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nZakres:\nUvst ≥ 1 V od 5 ns do 10 s CMC 1,0 ns\nUvst ≥ 1 V od 10 s do 10⁵ s CMC 8,0·10⁻¹¹\nPomiar bezpośredni licznikiem","reference":"MKF-t1, MKE-SRP.1","norm_bases":["MKF-t1","MKE-SRP.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czas trwania sygnałów impulsowych / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości czasu, częstotliwości Pomiar bezpośredni licznikiem Uvst ≥ 1 V od 5 ns do 10 s CMC 1,0 ns Uvst ≥ 1 V od 10 s do 10⁵ s CMC 8,0·10⁻¹¹ Délka trvání impulsních signálů / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje Kalibrace – veličiny času, frekvence Přímé měření čítačem Uvst ≥ 1 V 5 ns až 10 s CMC 1,0 ns Uvst ≥ 1 V 10 s až 10⁵ s CMC 8,0·10⁻¹¹ MKF-t1, MKE-SRP.1 Czas trwania sygnalow impulsowych / mierniki przedzialow czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsow, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu, czestotliwosci Pomiar bezposredni licznikiem Uvst ≥ 1 V od 5 ns do 10 s CMC 1,0 ns Uvst ≥ 1 V od 10 s do 10⁵ s CMC 8,0·10⁻¹¹ Delka trvani impulsnich signalu / Meridla casoveho intervalu, citace, osciloskopy, funkcni generatory, impulzni generatory, digitalni a mechanicke stopky, casovace, revizni pristroje Kalibrace – veliciny casu, frekvence Prime mereni citacem Uvst ≥ 1 V 5 ns az 10 s CMC 1,0 ns Uvst ≥ 1 V 10 s az 10⁵ s CMC 8,0·10⁻¹¹ MKF-t1, MKE-SRP.1","search_en":"Pulse signal duration / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments Calibration – time and frequency quantities Direct measurement by a counter Uvst ≥ 1 V 5 ns to 10 s CMC 1,0 ns Uvst ≥ 1 V 10 s to 10⁵ s CMC 8,0·10⁻¹¹ MKF-t1, MKE-SRP.1","search_zh":"脉冲信号持续时间 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪 校准 – 时间、频率量 用计数器直接测量 Uvst ≥ 1 V 5 ns 至 10 s CMC 1,0 ns Uvst ≥ 1 V 10 s 至 10⁵ s CMC 8,0·10⁻¹¹ MKF-t1, MKE-SRP.1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"389e18fd5be0e85f833a0c5c","lab_id":"6ade8b2aff068247617080fe","country":"CZ","accr_number":"2249","accr_body":"ČIA","row_label":"4","test_object":"Czas trwania sygnałów impulsowych / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych","test_object_en":"Pulse signal duration / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments","test_object_zh":"脉冲信号持续时间 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪","test_object_cs":"Délka trvání impulsních signálů / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje","methodology":"Wzorcowanie – wielkości czasu, częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间、频率量","methodology_cs":"Kalibrace – veličiny času, frekvence","parameters":[{"name":"","range":"od 10⁵ s do 4·10⁵ s","cmc":"3,6·10⁻⁸"}],"parameters_en":[{"name":"","range":"10⁵ s to 4·10⁵ s","cmc":"3,6·10⁻⁸"}],"parameters_zh":[{"name":"","range":"10⁵ s 至 4·10⁵ s","cmc":"3,6·10⁻⁸"}],"parameters_cs":[{"name":"","range":"10⁵ s až 4·10⁵ s","cmc":"3,6·10⁻⁸"}],"technique":"Bezpośrednie porównanie z kalibratorem","technique_en":"Direct comparison with a calibrator","technique_zh":"与校准器直接比较","technique_cs":"Přímé porovnání s kalibrátorem","techniques":["Bezpośrednie porównanie z kalibratorem"],"techniques_en":["Direct comparison with a calibrator"],"techniques_zh":["与校准器直接比较"],"techniques_cs":["Přímé porovnání s kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu, częstotliwości\nod 10⁵ s do 4·10⁵ s CMC 3,6·10⁻⁸\nBezpośrednie porównanie z kalibratorem","reference":"MKF-t1","norm_bases":["MKF-t1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu, częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间、频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času, frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czas trwania sygnałów impulsowych / mierniki przedziałów czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsów, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości czasu, częstotliwości Bezpośrednie porównanie z kalibratorem od 10⁵ s do 4·10⁵ s CMC 3,6·10⁻⁸ Délka trvání impulsních signálů / Měřidla časového intervalu, čítače, osciloskopy, funkční generátory, impulzní generátory, digitální a mechanické stopky, časovače, revizní přístroje Kalibrace – veličiny času, frekvence Přímé porovnání s kalibrátorem 10⁵ s až 4·10⁵ s CMC 3,6·10⁻⁸ MKF-t1 Czas trwania sygnalow impulsowych / mierniki przedzialow czasu, liczniki, oscyloskopy, generatory funkcyjne, generatory impulsow, stopery cyfrowe i mechaniczne, czasomierze, mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu, czestotliwosci Bezposrednie porownanie z kalibratorem od 10⁵ s do 4·10⁵ s CMC 3,6·10⁻⁸ Delka trvani impulsnich signalu / Meridla casoveho intervalu, citace, osciloskopy, funkcni generatory, impulzni generatory, digitalni a mechanicke stopky, casovace, revizni pristroje Kalibrace – veliciny casu, frekvence Prime porovnani s kalibratorem 10⁵ s az 4·10⁵ s CMC 3,6·10⁻⁸ MKF-t1","search_en":"Pulse signal duration / Time interval meters, counters, oscilloscopes, function generators, pulse generators, digital and mechanical stopwatches, timers, inspection instruments Calibration – time and frequency quantities Direct comparison with a calibrator 10⁵ s to 4·10⁵ s CMC 3,6·10⁻⁸ MKF-t1","search_zh":"脉冲信号持续时间 / 时间间隔测量仪器、计数器、示波器、函数发生器、脉冲发生器、数字和机械秒表、定时器、电气安装检测仪 校准 – 时间、频率量 与校准器直接比较 10⁵ s 至 4·10⁵ s CMC 3,6·10⁻⁸ MKF-t1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}