{"lab":{"_id":"69ad52a4de79e566650fd5cc","country":"CZ","accr_number":"1788","accr_body":"ČIA","address":"Dobronická č.p. 1371, 148 26 Praha 4","categories":["construction"],"city":"Praha 4","imported_at":"2026-03-08T10:42:44.590Z","methods_count":3,"name":"Zakládání staveb,a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1788_199_2023_CS.pdf","1788_199_2023_EN.pdf"],"scope_summary":"Badania konstrukcji geotechnicznych.","search_text":"zakládání staveb,a.s. dobronická č.p. 1371, 148 26 praha 4 1788","status":"active","updated_at":"2026-03-08T14:52:16.700Z","valid_from":"","valid_until":"14-04-2031","website":"www.zakladani.cz","location":{"type":"Point","coordinates":[14.4378,50.0755]},"email_confidence":"high","email_mx":true,"email_source":"https://www.zakladani.cz","map_coord":[50.04063,14.444959],"map_geo":"nominatim-city","certificate_date":"14.04.2026","certificate_no":"181/2026","certificate_replaces":"199/2023 z 25.04.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania konstrukcji geotechnicznych.","en":"Testing of geotechnical structures.","zh":"岩土工程结构的检测。","cs":"Zkoušení geotechnických konstrukcí."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Geotechniczne Laboratorium Badawcze","lab_division_cs":"Geotechnická zkušební laboratoř","lab_division_en":"Geotechnical Testing Laboratory","lab_division_zh":"岩土工程检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"PZ","pl":"procedura badawcza laboratorium","en":"Laboratory testing procedure","zh":"实验室检测程序","cs":"zkušební postup laboratoře"},{"abbr":"PIT","pl":"badanie ciągłości pala (Pile Integrity Test)","en":"Pile Integrity Test","zh":"桩身完整性检测（Pile Integrity Test）","cs":"zkouška integrity piloty (Pile Integrity Test)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"0fa0dfa053018e93c987266352f05b701352ed55ef1540415cb0565d2845daf5","source_pdf_url":"https://www.cai.cz/OA/pdf/181_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/181_2026_EN.pdf"},"methods":[{"_id":"5cc4bf20ad33d4781c6e4fd8","lab_id":"69ad52a4de79e566650fd5cc","country":"CZ","accr_number":"1788","accr_body":"ČIA","row_label":"1","test_object":"Pal wiercony, pal przemieszczeniowy, mikropal","test_object_en":"Bored pile, displacement piles, micropiles","test_object_zh":"钻孔桩、挤土桩、微型桩","test_object_cs":"Vrtaná pilota, ražená pilota, mikropilota","methodology":"Badanie obciążenia statycznego","methodology_en":"Static load testing","methodology_zh":"静载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie obciążenia statycznego","reference":"PZ 1 (ČSN EN 1536+A1, čl. 9.2; STN EN 1536+A1, čl. 9.2; ČSN EN ISO 22477-1, čl. 5; STN EN ISO 22477-1, čl. 5; ČSN EN 12699, čl. 9.3; STN EN 12699, čl. 9.3; ČSN EN 14199, čl. 9.3.2; STN EN 14199, čl. 9.3.2)","norm_bases":["PZ 1","ČSN EN 1536+A1, čl. 9.2","STN EN 1536+A1, čl. 9.2","ČSN EN ISO 22477-1, čl. 5","STN EN ISO 22477-1, čl. 5","ČSN EN 12699, čl. 9.3","STN EN 12699, čl. 9.3","ČSN EN 14199, čl. 9.3.2","STN EN 14199, čl. 9.3.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pal wiercony, pal przemieszczeniowy, mikropal Badanie obciążenia statycznego Vrtaná pilota, ražená pilota, mikropilota Statická zatěžovací zkouška PZ 1 (ČSN EN 1536+A1, čl. 9.2; STN EN 1536+A1, čl. 9.2; ČSN EN ISO 22477-1, čl. 5; STN EN ISO 22477-1, čl. 5; ČSN EN 12699, čl. 9.3; STN EN 12699, čl. 9.3; ČSN EN 14199, čl. 9.3.2; STN EN 14199, čl. 9.3.2) Pal wiercony, pal przemieszczeniowy, mikropal Badanie obciazenia statycznego Vrtana pilota, razena pilota, mikropilota Staticka zatezovaci zkouska PZ 1 (CSN EN 1536+A1, cl. 9.2; STN EN 1536+A1, cl. 9.2; CSN EN ISO 22477-1, cl. 5; STN EN ISO 22477-1, cl. 5; CSN EN 12699, cl. 9.3; STN EN 12699, cl. 9.3; CSN EN 14199, cl. 9.3.2; STN EN 14199, cl. 9.3.2)","search_en":"Bored pile, displacement piles, micropiles Static load testing PZ 1 (ČSN EN 1536+A1, čl. 9.2; STN EN 1536+A1, čl. 9.2; ČSN EN ISO 22477-1, čl. 5; STN EN ISO 22477-1, čl. 5; ČSN EN 12699, čl. 9.3; STN EN 12699, čl. 9.3; ČSN EN 14199, čl. 9.3.2; STN EN 14199, čl. 9.3.2)","search_zh":"钻孔桩、挤土桩、微型桩 静载试验 PZ 1 (ČSN EN 1536+A1, čl. 9.2; STN EN 1536+A1, čl. 9.2; ČSN EN ISO 22477-1, čl. 5; STN EN ISO 22477-1, čl. 5; ČSN EN 12699, čl. 9.3; STN EN 12699, čl. 9.3; ČSN EN 14199, čl. 9.3.2; STN EN 14199, čl. 9.3.2)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50ae1766aeac2dfb82e0e4ce","lab_id":"69ad52a4de79e566650fd5cc","country":"CZ","accr_number":"1788","accr_body":"ČIA","row_label":"2","test_object":"Pal wiercony, pal wbijany, ściana szczelinowa","test_object_en":"Bored pile, driven pile, diaphragm wall","test_object_zh":"钻孔桩、打入桩、地下连续墙","test_object_cs":"Vrtaná pilota, beraněná pilota, podzemní stěna","methodology":"Badanie ciągłości pala metodą akustyczną (PIT)","methodology_en":"Pile integrity testing using the acoustic method (PIT)","methodology_zh":"声波法桩身完整性检测（PIT）","methodology_cs":"Zkouška integrity akustickou metodou (PIT)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie ciągłości pala metodą akustyczną (PIT)","reference":"PZ 2 (ČSN EN 1536+A1, čl. 9.2.3; STN EN 1536+A1, 9.2.3; ČSN EN 1538+A1, čl. 9.5; STN EN 1538+A1, čl. 9.5; Návod výrobce Pile Echo Tester)","norm_bases":["PZ 2","ČSN EN 1536+A1, čl. 9.2.3","STN EN 1536+A1, 9.2.3","ČSN EN 1538+A1, čl. 9.5","STN EN 1538+A1, čl. 9.5","Návod výrobce Pile Echo Tester"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pal wiercony, pal wbijany, ściana szczelinowa Badanie ciągłości pala metodą akustyczną (PIT) Vrtaná pilota, beraněná pilota, podzemní stěna Zkouška integrity akustickou metodou (PIT) PZ 2 (ČSN EN 1536+A1, čl. 9.2.3; STN EN 1536+A1, 9.2.3; ČSN EN 1538+A1, čl. 9.5; STN EN 1538+A1, čl. 9.5; Návod výrobce Pile Echo Tester) Pal wiercony, pal wbijany, sciana szczelinowa Badanie ciaglosci pala metoda akustyczna (PIT) Vrtana pilota, beranena pilota, podzemni stena Zkouska integrity akustickou metodou (PIT) PZ 2 (CSN EN 1536+A1, cl. 9.2.3; STN EN 1536+A1, 9.2.3; CSN EN 1538+A1, cl. 9.5; STN EN 1538+A1, cl. 9.5; Navod vyrobce Pile Echo Tester)","search_en":"Bored pile, driven pile, diaphragm wall Pile integrity testing using the acoustic method (PIT) PZ 2 (ČSN EN 1536+A1, čl. 9.2.3; STN EN 1536+A1, 9.2.3; ČSN EN 1538+A1, čl. 9.5; STN EN 1538+A1, čl. 9.5; Návod výrobce Pile Echo Tester)","search_zh":"钻孔桩、打入桩、地下连续墙 声波法桩身完整性检测（PIT） PZ 2 (ČSN EN 1536+A1, čl. 9.2.3; STN EN 1536+A1, 9.2.3; ČSN EN 1538+A1, čl. 9.5; STN EN 1538+A1, čl. 9.5; Návod výrobce Pile Echo Tester)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"12568aec7b9fd14eb08b5917","lab_id":"69ad52a4de79e566650fd5cc","country":"CZ","accr_number":"1788","accr_body":"ČIA","row_label":"3","test_object":"Kotwa gruntowa","test_object_en":"Ground anchor","test_object_zh":"土层锚杆","test_object_cs":"Zemní kotva","methodology":"Badanie nośności na rozciąganie i naprężanie","methodology_en":"Tensile load capacity test and stressing","methodology_zh":"抗拉承载力试验和张拉","methodology_cs":"Zkouška únosnosti v tahu a napínání","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie nośności na rozciąganie i naprężanie","reference":"PZ 3 (ČSN EN 1537, kap. 9; STN EN 1537, kap. 9; ČSN EN ISO 22477-5, kap. 8; STN EN ISO 22477-5, kap. 8)","norm_bases":["PZ 3","ČSN EN 1537, kap. 9","STN EN 1537, kap. 9","ČSN EN ISO 22477-5, kap. 8","STN EN ISO 22477-5, kap. 8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kotwa gruntowa Badanie nośności na rozciąganie i naprężanie Zemní kotva Zkouška únosnosti v tahu a napínání PZ 3 (ČSN EN 1537, kap. 9; STN EN 1537, kap. 9; ČSN EN ISO 22477-5, kap. 8; STN EN ISO 22477-5, kap. 8) Kotwa gruntowa Badanie nosnosci na rozciaganie i naprezanie Zemni kotva Zkouska unosnosti v tahu a napinani PZ 3 (CSN EN 1537, kap. 9; STN EN 1537, kap. 9; CSN EN ISO 22477-5, kap. 8; STN EN ISO 22477-5, kap. 8)","search_en":"Ground anchor Tensile load capacity test and stressing PZ 3 (ČSN EN 1537, kap. 9; STN EN 1537, kap. 9; ČSN EN ISO 22477-5, kap. 8; STN EN ISO 22477-5, kap. 8)","search_zh":"土层锚杆 抗拉承载力试验和张拉 PZ 3 (ČSN EN 1537, kap. 9; STN EN 1537, kap. 9; ČSN EN ISO 22477-5, kap. 8; STN EN ISO 22477-5, kap. 8)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}