{"lab":{"_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","address":"Kosovská 10, 586 37 Jihlava","categories":["construction"],"city":"Jihlava","imported_at":"2026-03-08T10:42:44.590Z","methods_count":59,"name":"COLAS CZ, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1780_525_2025_CS.pdf","1780_525_2025_EN.pdf"],"scope_summary":"Oznaczanie właściwości betonu świeżego i stwardniałego, mieszanek mineralno-asfaltowych, kruszyw, gruntów i gotowych nawierzchni, wraz z pobieraniem próbek, oraz oznaczanie wielopierścieniowych węglowodorów aromatycznych, w zakresie określonym w załączniku do świadectwa.","search_text":"colas cz, a.s. kosovská 10, 586 37 jihlava other","status":"active","updated_at":"2026-03-08T14:52:16.482Z","valid_from":"","valid_until":"20-10-2030","website":"www.colas.cz","parsed_at":"2026-09-28T12:00:00.000Z","location":{"type":"Point","coordinates":[15.5912,49.3961]},"map_coord":[49.392373,15.60222],"map_geo":"nominatim-street","certificate_date":"20.10.2025","certificate_no":"525/2025","certificate_replaces":"644/2024 z 29.11.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Oznaczanie właściwości betonu świeżego i stwardniałego, mieszanek mineralno-asfaltowych, kruszyw, gruntów i gotowych nawierzchni, wraz z pobieraniem próbek, oraz oznaczanie wielopierścieniowych węglowodorów aromatycznych, w zakresie określonym w załączniku do świadectwa.","en":"Determination of the properties of fresh and hardened concrete, asphalt mixtures, aggregates, soils and pavements, including sampling, and determination of polycyclic aromatic hydrocarbons to the extent as specified in the appendix to this Certificate.","zh":"新拌和硬化混凝土、沥青混合料、集料、土和路面成品的性能测定（含采样），以及多环芳烃测定，范围见本证书附件。","cs":"Stanovení vlastností čerstvého a ztvrdlého betonu, asfaltových směsí, kameniva, zemin a hotových úprav, včetně vzorkování, a stanovení polycyklických aromatických uhlovodíků, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Centralne COLAS CZ","lab_division_cs":"Centrální laboratoř COLAS CZ","lab_division_en":"COLAS CZ Central Laboratory","lab_division_zh":"COLAS CZ中心实验室","lab_locations":[{"code":null,"name":"COLAS CZ, a.s.","street":"Kosovská 10","postal_code":"586 37","city":"Jihlava","is_hq":true,"address":"Kosovská 10, 586 37 Jihlava","site":"58637|kosovská10"},{"code":null,"name":"Jihlava","street":"Kosovská 10","postal_code":"586 37","city":"Jihlava","is_hq":false,"address":"Kosovská 10, 586 37 Jihlava","site":"58637|kosovská10"},{"code":null,"name":"Znojmo","street":"Dyje ev.č. 511","postal_code":"669 02","city":"Znojmo","is_hq":false,"address":"Dyje ev.č. 511, 669 02 Znojmo","site":"66902|dyjeevč511"},{"code":null,"name":"Zachód","street":"Vrbice 67","postal_code":"364 52","city":"Žlutice","is_hq":false,"address":"Vrbice 67, 364 52 Žlutice","site":"36452|vrbice67"}],"lab_locations_en":[{"code":null,"name":"COLAS CZ, a.s.","street":"Kosovská 10","postal_code":"586 37","city":"Jihlava","is_hq":true,"address":"Kosovská 10, 586 37 Jihlava","site":"58637|kosovská10"},{"code":null,"name":"Jihlava","street":"Kosovská 10","postal_code":"586 37","city":"Jihlava","is_hq":false,"address":"Kosovská 10, 586 37 Jihlava","site":"58637|kosovská10"},{"code":null,"name":"Znojmo","street":"Dyje ev.č. 511","postal_code":"669 02","city":"Znojmo","is_hq":false,"address":"Dyje ev.č. 511, 669 02 Znojmo","site":"66902|dyjeevč511"},{"code":null,"name":"Západ","street":"Vrbice 67","postal_code":"364 52","city":"Žlutice","is_hq":false,"address":"Vrbice 67, 364 52 Žlutice","site":"36452|vrbice67"}],"lab_locations_zh":[{"code":null,"name":"COLAS CZ, a.s.","street":"Kosovská 10","postal_code":"586 37","city":"Jihlava","is_hq":true,"address":"Kosovská 10, 586 37 Jihlava","site":"58637|kosovská10"},{"code":null,"name":"伊赫拉瓦","street":"Kosovská 10","postal_code":"586 37","city":"Jihlava","is_hq":false,"address":"Kosovská 10, 586 37 Jihlava","site":"58637|kosovská10"},{"code":null,"name":"兹诺伊莫","street":"Dyje ev.č. 511","postal_code":"669 02","city":"Znojmo","is_hq":false,"address":"Dyje ev.č. 511, 669 02 Znojmo","site":"66902|dyjeevč511"},{"code":null,"name":"西区","street":"Vrbice 67","postal_code":"364 52","city":"Žlutice","is_hq":false,"address":"Vrbice 67, 364 52 Žlutice","site":"36452|vrbice67"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"PAU","pl":"wielopierścieniowe węglowodory aromatyczne (WWA)","en":"Polycyclic Aromatic Hydrocarbons","zh":"多环芳烃","cs":"polycyklické aromatické uhlovodíky"},{"abbr":"GC/MS","pl":"chromatografia gazowa / spektrometria mas","en":"Gas Chromatography / Mass Spectrometry","zh":"气相色谱/质谱法","cs":"plynová chromatografie / hmotnostní spektrometrie (Gas Chromatography / Mass Spectrometric)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"4d94b24b89736c5d20bd8cbf7f2e67295046d4476a2181df478c636e2452b1b4","source_pdf_url":"https://www.cai.cz/OA/pdf/525_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/525_2025_EN.pdf"},"methods":[{"_id":"4e6096f885424c57c5aaf5d2","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka mineralno-asfaltowa, lepiszcze asfaltowe, destrukt asfaltowy i inne materiały zawierające składniki asfaltowe","test_object_en":"Asphalt mixture, asphalt binder, recycled asphalt and other materials containing asphalt","test_object_zh":"沥青混合料、沥青结合料、再生沥青及其他含沥青成分的材料","test_object_cs":"Asfaltová směs, asfaltové pojivo, asfaltový recyklát a další materiály obsahující asfaltové prvky","methodology":"Oznaczanie WWA metodą GC/MS i ich sumy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of PAH by GC/MS method and their sum by calculation from the measured values","methodology_zh":"GC/MS法多环芳烃测定及根据测量值计算其总和","methodology_cs":"Stanovení PAU metodou GC/MS a jejich sumy výpočtem z naměřených hodnot","parameters":[{"name":"Naftalen","range":""},{"name":"Acenaftylen","range":""},{"name":"Acenaften","range":""},{"name":"Fluoren","range":""},{"name":"Fenantren","range":""},{"name":"Antracen","range":""},{"name":"Fluoranten","range":""},{"name":"Piren","range":""},{"name":"Benzo(a)antracen","range":""},{"name":"Chryzen","range":""},{"name":"Benzo(b)fluoranten","range":""},{"name":"Benzo(k)fluoranten","range":""},{"name":"Benzo(a)piren","range":""},{"name":"Indeno(1,2,3-cd)piren","range":""},{"name":"Benzo(g,h,i)perylen","range":""},{"name":"Dibenzo(a,h)antracen","range":""}],"parameters_en":[{"name":"Naphthalene","range":""},{"name":"Acenaphthylene","range":""},{"name":"Acenaphthene","range":""},{"name":"Fluorene","range":""},{"name":"Phenanthrene","range":""},{"name":"Anthracene","range":""},{"name":"Fluoranthene","range":""},{"name":"Pyrene","range":""},{"name":"Benzo[a]anthracene","range":""},{"name":"Chrysene","range":""},{"name":"Benzo[b]fluoranthene","range":""},{"name":"Benzo(k) fluoranthene","range":""},{"name":"Benzo[a]pyrene","range":""},{"name":"Indeno[1,2,3-cd]pyrene","range":""},{"name":"Benzo[ghi]perylene","range":""},{"name":"Dibenzo(a,h)anthracene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"苊烯","range":""},{"name":"苊","range":""},{"name":"芴","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"荧蒽","range":""},{"name":"芘","range":""},{"name":"苯并[a]蒽","range":""},{"name":"䓛","range":""},{"name":"苯并[b]荧蒽","range":""},{"name":"苯并[k]荧蒽","range":""},{"name":"苯并[a]芘","range":""},{"name":"茚并[1,2,3-cd]芘","range":""},{"name":"苯并[ghi]苝","range":""},{"name":"二苯并[a,h]蒽","range":""}],"parameters_cs":[{"name":"naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fenanthren","range":""},{"name":"anthracen","range":""},{"name":"fluoranthren","range":""},{"name":"pyren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chrysen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"bento(a)pyren","range":""},{"name":"indeno[1,2,3-cd]pyren","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"dibenzo(a,h)antracen","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie WWA metodą GC/MS i ich sumy obliczeniowo z wartości zmierzonych\nZakres:\nNaftalen\nAcenaftylen\nAcenaften\nFluoren\nFenantren\nAntracen\nFluoranten\nPiren\nBenzo(a)antracen\nChryzen\nBenzo(b)fluoranten\nBenzo(k)fluoranten\nBenzo(a)piren\nIndeno(1,2,3-cd)piren\nBenzo(g,h,i)perylen\nDibenzo(a,h)antracen","reference":"SOP-PAH-01 (ČSN EN 15527:2009)","norm_bases":["SOP-PAH-01","ČSN EN 15527:2009"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa, lepiszcze asfaltowe, destrukt asfaltowy i inne materiały zawierające składniki asfaltowe Oznaczanie WWA metodą GC/MS i ich sumy obliczeniowo z wartości zmierzonych Naftalen  Acenaftylen  Acenaften  Fluoren  Fenantren  Antracen  Fluoranten  Piren  Benzo(a)antracen  Chryzen  Benzo(b)fluoranten  Benzo(k)fluoranten  Benzo(a)piren  Indeno(1,2,3-cd)piren  Benzo(g,h,i)perylen  Dibenzo(a,h)antracen  Asfaltová směs, asfaltové pojivo, asfaltový recyklát a další materiály obsahující asfaltové prvky Stanovení PAU metodou GC/MS a jejich sumy výpočtem z naměřených hodnot naftalen  acenaftylen  acenaften  fluoren  fenanthren  anthracen  fluoranthren  pyren  benzo(a)antracen  chrysen  benzo(b)fluoranten  benzo(k)fluoranten  bento(a)pyren  indeno[1,2,3-cd]pyren  benzo(g,h,i)perylen  dibenzo(a,h)antracen  SOP-PAH-01 (ČSN EN 15527:2009) Mieszanka mineralno-asfaltowa, lepiszcze asfaltowe, destrukt asfaltowy i inne materialy zawierajace skladniki asfaltowe Oznaczanie WWA metoda GC/MS i ich sumy obliczeniowo z wartosci zmierzonych Naftalen  Acenaftylen  Acenaften  Fluoren  Fenantren  Antracen  Fluoranten  Piren  Benzo(a)antracen  Chryzen  Benzo(b)fluoranten  Benzo(k)fluoranten  Benzo(a)piren  Indeno(1,2,3-cd)piren  Benzo(g,h,i)perylen  Dibenzo(a,h)antracen  Asfaltova smes, asfaltove pojivo, asfaltovy recyklat a dalsi materialy obsahujici asfaltove prvky Stanoveni PAU metodou GC/MS a jejich sumy vypoctem z namerenych hodnot naftalen  acenaftylen  acenaften  fluoren  fenanthren  anthracen  fluoranthren  pyren  benzo(a)antracen  chrysen  benzo(b)fluoranten  benzo(k)fluoranten  bento(a)pyren  indeno[1,2,3-cd]pyren  benzo(g,h,i)perylen  dibenzo(a,h)antracen  SOP-PAH-01 (CSN EN 15527:2009)","search_en":"Asphalt mixture, asphalt binder, recycled asphalt and other materials containing asphalt Determination of PAH by GC/MS method and their sum by calculation from the measured values Naphthalene  Acenaphthylene  Acenaphthene  Fluorene  Phenanthrene  Anthracene  Fluoranthene  Pyrene  Benzo[a]anthracene  Chrysene  Benzo[b]fluoranthene  Benzo(k) fluoranthene  Benzo[a]pyrene  Indeno[1,2,3-cd]pyrene  Benzo[ghi]perylene  Dibenzo(a,h)anthracene  SOP-PAH-01 (ČSN EN 15527:2009)","search_zh":"沥青混合料、沥青结合料、再生沥青及其他含沥青成分的材料 GC/MS法多环芳烃测定及根据测量值计算其总和 萘  苊烯  苊  芴  菲  蒽  荧蒽  芘  苯并[a]蒽  䓛  苯并[b]荧蒽  苯并[k]荧蒽  苯并[a]芘  茚并[1,2,3-cd]芘  苯并[ghi]苝  二苯并[a,h]蒽  SOP-PAH-01 (ČSN EN 15527:2009)","categories":["construction","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"206294614c05d69ea947039e","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"2","test_object":"Mieszanka mineralno-asfaltowa, lepiszcze asfaltowe, destrukt asfaltowy i inne materiały zawierające składniki asfaltowe","test_object_en":"Asphalt mixture, asphalt binder, recycled asphalt and other materials containing asphalt","test_object_zh":"沥青混合料、沥青结合料、再生沥青及其他含沥青成分的材料","test_object_cs":"Asfaltová směs, asfaltové pojivo, asfaltový recyklát a další materiály obsahující asfaltové prvky","methodology":"Oznaczanie suchej masy metodą wagową","methodology_en":"Determination of dry matter by gravimetry","methodology_zh":"重量法干物质测定","methodology_cs":"Stanovení sušiny gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy metodą wagową","reference":"ČSN ISO 11465","norm_bases":["ČSN ISO 11465"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa, lepiszcze asfaltowe, destrukt asfaltowy i inne materiały zawierające składniki asfaltowe Oznaczanie suchej masy metodą wagową Asfaltová směs, asfaltové pojivo, asfaltový recyklát a další materiály obsahující asfaltové prvky Stanovení sušiny gravimetricky ČSN ISO 11465 Mieszanka mineralno-asfaltowa, lepiszcze asfaltowe, destrukt asfaltowy i inne materialy zawierajace skladniki asfaltowe Oznaczanie suchej masy metoda wagowa Asfaltova smes, asfaltove pojivo, asfaltovy recyklat a dalsi materialy obsahujici asfaltove prvky Stanoveni susiny gravimetricky CSN ISO 11465","search_en":"Asphalt mixture, asphalt binder, recycled asphalt and other materials containing asphalt Determination of dry matter by gravimetry ČSN ISO 11465","search_zh":"沥青混合料、沥青结合料、再生沥青及其他含沥青成分的材料 重量法干物质测定 ČSN ISO 11465","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec03c9acdb7b235f9fbf45a6","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"3","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – badanie opadu stożka","methodology_en":"Determination of consistency - Slump test","methodology_zh":"稠度测定 – 坍落度试验","methodology_cs":"Stanovení konzistence – zkouška sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – badanie opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – badanie opadu stożka Čerstvý beton Stanovení konzistence – zkouška sednutím ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – badanie opadu stozka Cerstvy beton Stanoveni konzistence – zkouska sednutim CSN EN 12350-2","search_en":"Fresh concrete Determination of consistency - Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定 – 坍落度试验 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d142c1e2ae18003ae8ceb9ad","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"3","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – badanie opadu stożka","methodology_en":"Determination of consistency - Slump test","methodology_zh":"稠度测定 – 坍落度试验","methodology_cs":"Stanovení konzistence – zkouška sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – badanie opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – badanie opadu stożka Čerstvý beton Stanovení konzistence – zkouška sednutím ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – badanie opadu stozka Cerstvy beton Stanoveni konzistence – zkouska sednutim CSN EN 12350-2","search_en":"Fresh concrete Determination of consistency - Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定 – 坍落度试验 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f626d1562767250c1f09407","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"4","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – stopień zagęszczalności","methodology_en":"Determination of consistency - degree of compactibility","methodology_zh":"稠度测定 – 密实度","methodology_cs":"Stanovení konzistence – stupeň zhutnitelnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – stopień zagęszczalności","reference":"ČSN EN 12350-4","norm_bases":["ČSN EN 12350-4"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – stopień zagęszczalności Čerstvý beton Stanovení konzistence – stupeň zhutnitelnosti ČSN EN 12350-4 Beton swiezy Oznaczanie konsystencji – stopien zageszczalnosci Cerstvy beton Stanoveni konzistence – stupen zhutnitelnosti CSN EN 12350-4","search_en":"Fresh concrete Determination of consistency - degree of compactibility ČSN EN 12350-4","search_zh":"新拌混凝土 稠度测定 – 密实度 ČSN EN 12350-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d7152f002516b13ac6bbeec","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"4","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – stopień zagęszczalności","methodology_en":"Determination of consistency - degree of compactibility","methodology_zh":"稠度测定 – 密实度","methodology_cs":"Stanovení konzistence – stupeň zhutnitelnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – stopień zagęszczalności","reference":"ČSN EN 12350-4","norm_bases":["ČSN EN 12350-4"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – stopień zagęszczalności Čerstvý beton Stanovení konzistence – stupeň zhutnitelnosti ČSN EN 12350-4 Beton swiezy Oznaczanie konsystencji – stopien zageszczalnosci Cerstvy beton Stanoveni konzistence – stupen zhutnitelnosti CSN EN 12350-4","search_en":"Fresh concrete Determination of consistency - degree of compactibility ČSN EN 12350-4","search_zh":"新拌混凝土 稠度测定 – 密实度 ČSN EN 12350-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"508d8945cad14d222c2d3d99","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"5","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of bulk density","methodology_zh":"表观密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości objętościowej Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci objetosciowej Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of bulk density ČSN EN 12350-6","search_zh":"新拌混凝土 表观密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e8a2483e3fda21bf614b2574","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"5","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of bulk density","methodology_zh":"表观密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości objętościowej Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci objetosciowej Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of bulk density ČSN EN 12350-6","search_zh":"新拌混凝土 表观密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0fee27df5a32b68f090a440","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"6","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content - pressure method","methodology_zh":"含气量测定 – 压力法","methodology_cs":"Stanovení obsahu vzduchu – tlaková metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7, mimo čl. 5","norm_bases":["ČSN EN 12350-7, mimo čl. 5"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlaková metoda ČSN EN 12350-7, mimo čl. 5 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakova metoda CSN EN 12350-7, mimo cl. 5","search_en":"Fresh concrete Determination of air content - pressure method ČSN EN 12350-7, mimo čl. 5","search_zh":"新拌混凝土 含气量测定 – 压力法 ČSN EN 12350-7, mimo čl. 5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1683880807988b7c5714f77","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"6","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content - pressure method","methodology_zh":"含气量测定 – 压力法","methodology_cs":"Stanovení obsahu vzduchu – tlaková metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7, mimo čl. 5","norm_bases":["ČSN EN 12350-7, mimo čl. 5"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlaková metoda ČSN EN 12350-7, mimo čl. 5 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakova metoda CSN EN 12350-7, mimo cl. 5","search_en":"Fresh concrete Determination of air content - pressure method ČSN EN 12350-7, mimo čl. 5","search_zh":"新拌混凝土 含气量测定 – 压力法 ČSN EN 12350-7, mimo čl. 5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c98879e6c9cb7c0e9095248b","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"7","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of bulk density","methodology_zh":"表观密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12390-7","norm_bases":["ČSN EN 12390-7"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości objętościowej Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7 Beton stwardnialy Oznaczanie gestosci objetosciowej Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7","search_en":"Hardened concrete Determination of bulk density ČSN EN 12390-7","search_zh":"硬化混凝土 表观密度测定 ČSN EN 12390-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bd089e4d6f79b586449a09d","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"7","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of bulk density","methodology_zh":"表观密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12390-7","norm_bases":["ČSN EN 12390-7"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości objętościowej Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7 Beton stwardnialy Oznaczanie gestosci objetosciowej Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7","search_en":"Hardened concrete Determination of bulk density ČSN EN 12390-7","search_zh":"硬化混凝土 表观密度测定 ČSN EN 12390-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d0bb0f4c1d49d3ff0a3443e7","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"8","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9a73b52983e5dcf9e15c6534","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"8","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5facf353474704d928a0c90","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"9","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakovou vodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakovou vodou ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakovou vodou CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bd15c8ce98b15bb4db7818f7","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"10","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL) metodą cykli automatycznych","methodology_en":"Determination of surface resistance to water and chemical de-icing agents by automatic cycling","methodology_zh":"自动循环法表面耐水和化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu proti působení vody a CHRL automatickým cyklováním","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL) metodą cykli automatycznych","reference":"ČSN 73 1326, metoda A","norm_bases":["ČSN 73 1326, metoda A"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL) metodą cykli automatycznych Ztvrdlý beton Stanovení odolnosti povrchu proti působení vody a CHRL automatickým cyklováním ČSN 73 1326, metoda A Beton stwardnialy Oznaczanie odpornosci powierzchni na dzialanie wody i chemicznych srodkow odladzajacych (CHRL) metoda cykli automatycznych Ztvrdly beton Stanoveni odolnosti povrchu proti pusobeni vody a CHRL automatickym cyklovanim CSN 73 1326, metoda A","search_en":"Hardened concrete Determination of surface resistance to water and chemical de-icing agents by automatic cycling ČSN 73 1326, metoda A","search_zh":"硬化混凝土 自动循环法表面耐水和化学除冰剂性能测定 ČSN 73 1326, metoda A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8dfe7489f730bb86b7955aa5","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"11","test_object":"Nawierzchnie z betonu cementowego","test_object_en":"Concrete pavements","test_object_zh":"水泥混凝土路面","test_object_cs":"Cementobetonové kryty","methodology":"Oznaczanie grubości warstw na odwiercie","methodology_en":"Determination of layer thickness on a cored specimen","methodology_zh":"芯样层厚测定","methodology_cs":"Stanovení tloušťky vrstev na vývrtu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości warstw na odwiercie","reference":"ČSN EN 13863-3","norm_bases":["ČSN EN 13863-3"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawierzchnie z betonu cementowego Oznaczanie grubości warstw na odwiercie Cementobetonové kryty Stanovení tloušťky vrstev na vývrtu ČSN EN 13863-3 Nawierzchnie z betonu cementowego Oznaczanie grubosci warstw na odwiercie Cementobetonove kryty Stanoveni tloustky vrstev na vyvrtu CSN EN 13863-3","search_en":"Concrete pavements Determination of layer thickness on a cored specimen ČSN EN 13863-3","search_zh":"水泥混凝土路面 芯样层厚测定 ČSN EN 13863-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"92d44863196dc8e3aacfe07c","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"12","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie zawartości rozpuszczalnego lepiszcza","methodology_en":"Determination of soluble binder content","methodology_zh":"可溶结合料含量测定","methodology_cs":"Stanovení obsahu rozpustného pojiva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości rozpuszczalnego lepiszcza","reference":"ČSN EN 12697-1","norm_bases":["ČSN EN 12697-1"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie zawartości rozpuszczalnego lepiszcza Asfaltová směs Stanovení obsahu rozpustného pojiva ČSN EN 12697-1 Mieszanka mineralno-asfaltowa Oznaczanie zawartosci rozpuszczalnego lepiszcza Asfaltova smes Stanoveni obsahu rozpustneho pojiva CSN EN 12697-1","search_en":"Asphalt mixture Determination of soluble binder content ČSN EN 12697-1","search_zh":"沥青混合料 可溶结合料含量测定 ČSN EN 12697-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d831e1f19aeeb5d41fe7a3d0","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"13","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of grain size","methodology_zh":"粒度测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 12697-2+A1","norm_bases":["ČSN EN 12697-2+A1"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie uziarnienia Asfaltová směs Stanovení zrnitosti ČSN EN 12697-2+A1 Mieszanka mineralno-asfaltowa Oznaczanie uziarnienia Asfaltova smes Stanoveni zrnitosti CSN EN 12697-2+A1","search_en":"Asphalt mixture Determination of grain size ČSN EN 12697-2+A1","search_zh":"沥青混合料 粒度测定 ČSN EN 12697-2+A1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82e3307cc8f54accf14fb8ea","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"14","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of bulk density","methodology_zh":"表观密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12697-6, postup B, D","norm_bases":["ČSN EN 12697-6, postup B, D"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie gęstości objętościowej Asfaltová směs Stanovení objemové hmotnosti ČSN EN 12697-6, postup B, D Mieszanka mineralno-asfaltowa Oznaczanie gestosci objetosciowej Asfaltova smes Stanoveni objemove hmotnosti CSN EN 12697-6, postup B, D","search_en":"Asphalt mixture Determination of bulk density ČSN EN 12697-6, postup B, D","search_zh":"沥青混合料 表观密度测定 ČSN EN 12697-6, postup B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"653a60e28565bd8099be7b0b","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"14","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of bulk density","methodology_zh":"表观密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12697-6, postup B, D","norm_bases":["ČSN EN 12697-6, postup B, D"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie gęstości objętościowej Asfaltová směs Stanovení objemové hmotnosti ČSN EN 12697-6, postup B, D Mieszanka mineralno-asfaltowa Oznaczanie gestosci objetosciowej Asfaltova smes Stanoveni objemove hmotnosti CSN EN 12697-6, postup B, D","search_en":"Asphalt mixture Determination of bulk density ČSN EN 12697-6, postup B, D","search_zh":"沥青混合料 表观密度测定 ČSN EN 12697-6, postup B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22c3d3a2dda5aad29c4e84ef","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"15","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie gęstości objętościowej maksymalnej","methodology_en":"Determination of the maximum density","methodology_zh":"最大密度测定","methodology_cs":"Stanovení maximální objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej maksymalnej","reference":"ČSN EN 12697-5","norm_bases":["ČSN EN 12697-5"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie gęstości objętościowej maksymalnej Asfaltová směs Stanovení maximální objemové hmotnosti ČSN EN 12697-5 Mieszanka mineralno-asfaltowa Oznaczanie gestosci objetosciowej maksymalnej Asfaltova smes Stanoveni maximalni objemove hmotnosti CSN EN 12697-5","search_en":"Asphalt mixture Determination of the maximum density ČSN EN 12697-5","search_zh":"沥青混合料 最大密度测定 ČSN EN 12697-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9276028493fdf7dbe3f6729","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"16","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie zawartości wolnych przestrzeni","methodology_en":"Determination of voids","methodology_zh":"空隙率测定","methodology_cs":"Stanovení mezerovitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wolnych przestrzeni","reference":"ČSN EN 12697-8","norm_bases":["ČSN EN 12697-8"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie zawartości wolnych przestrzeni Asfaltová směs Stanovení mezerovitosti ČSN EN 12697-8 Mieszanka mineralno-asfaltowa Oznaczanie zawartosci wolnych przestrzeni Asfaltova smes Stanoveni mezerovitosti CSN EN 12697-8","search_en":"Asphalt mixture Determination of voids ČSN EN 12697-8","search_zh":"沥青混合料 空隙率测定 ČSN EN 12697-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c39a2a48fd3f0002dcd781d","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"16","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie zawartości wolnych przestrzeni","methodology_en":"Determination of voids","methodology_zh":"空隙率测定","methodology_cs":"Stanovení mezerovitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wolnych przestrzeni","reference":"ČSN EN 12697-8","norm_bases":["ČSN EN 12697-8"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie zawartości wolnych przestrzeni Asfaltová směs Stanovení mezerovitosti ČSN EN 12697-8 Mieszanka mineralno-asfaltowa Oznaczanie zawartosci wolnych przestrzeni Asfaltova smes Stanoveni mezerovitosti CSN EN 12697-8","search_en":"Asphalt mixture Determination of voids ČSN EN 12697-8","search_zh":"沥青混合料 空隙率测定 ČSN EN 12697-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c150c8599fabde7054437063","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"17","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Pomiar temperatury","methodology_en":"Measurement of temperature","methodology_zh":"温度测量","methodology_cs":"Měření teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar temperatury","reference":"ČSN EN 12697-13","norm_bases":["ČSN EN 12697-13"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Pomiar temperatury Asfaltová směs Měření teploty ČSN EN 12697-13 Mieszanka mineralno-asfaltowa Pomiar temperatury Asfaltova smes Mereni teploty CSN EN 12697-13","search_en":"Asphalt mixture Measurement of temperature ČSN EN 12697-13","search_zh":"沥青混合料 温度测量 ČSN EN 12697-13","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"78aa7967492c9d7d0730486e","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"18","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie wymiarów","methodology_en":"Determination of dimensions","methodology_zh":"尺寸测定","methodology_cs":"Stanovení rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wymiarów","reference":"ČSN EN 12697-29","norm_bases":["ČSN EN 12697-29"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie wymiarów Asfaltová směs Stanovení rozměrů ČSN EN 12697-29 Mieszanka mineralno-asfaltowa Oznaczanie wymiarow Asfaltova smes Stanoveni rozmeru CSN EN 12697-29","search_en":"Asphalt mixture Determination of dimensions ČSN EN 12697-29","search_zh":"沥青混合料 尺寸测定 ČSN EN 12697-29","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25d329ea99699b1c7adeed64","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"19","test_object":"Warstwa asfaltowa","test_object_en":"Asphalt layer","test_object_zh":"沥青层","test_object_cs":"Asfaltová vrstva","methodology":"Oznaczanie grubości","methodology_en":"Determination of thickness","methodology_zh":"厚度测定","methodology_cs":"Stanovení tloušťky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości","reference":"ČSN EN 12697-36, čl. 6.1","norm_bases":["ČSN EN 12697-36, čl. 6.1"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa asfaltowa Oznaczanie grubości Asfaltová vrstva Stanovení tloušťky ČSN EN 12697-36, čl. 6.1 Warstwa asfaltowa Oznaczanie grubosci Asfaltova vrstva Stanoveni tloustky CSN EN 12697-36, cl. 6.1","search_en":"Asphalt layer Determination of thickness ČSN EN 12697-36, čl. 6.1","search_zh":"沥青层 厚度测定 ČSN EN 12697-36, čl. 6.1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d28f4e001423593a39a018a","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"19","test_object":"Warstwa asfaltowa","test_object_en":"Asphalt layer","test_object_zh":"沥青层","test_object_cs":"Asfaltová vrstva","methodology":"Oznaczanie grubości","methodology_en":"Determination of thickness","methodology_zh":"厚度测定","methodology_cs":"Stanovení tloušťky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości","reference":"ČSN EN 12697-36, čl. 6.1","norm_bases":["ČSN EN 12697-36, čl. 6.1"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa asfaltowa Oznaczanie grubości Asfaltová vrstva Stanovení tloušťky ČSN EN 12697-36, čl. 6.1 Warstwa asfaltowa Oznaczanie grubosci Asfaltova vrstva Stanoveni tloustky CSN EN 12697-36, cl. 6.1","search_en":"Asphalt layer Determination of thickness ČSN EN 12697-36, čl. 6.1","search_zh":"沥青层 厚度测定 ČSN EN 12697-36, čl. 6.1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26a1d630f86da63f129cea7b","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"20","test_object":"Warstwa asfaltowa","test_object_en":"Asphalt layer","test_object_zh":"沥青层","test_object_cs":"Asfaltová vrstva","methodology":"Oznaczanie wytrzymałości połączenia i wskaźnika zagęszczenia warstw","methodology_en":"Determination of the bond strength and degree of compaction","methodology_zh":"层间粘结强度和压实度测定","methodology_cs":"Stanovení pevnosti spojení a míry zhutnění vrstev","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości połączenia i wskaźnika zagęszczenia warstw","reference":"ČSN 73 6160, čl. 7.2, 7.3","norm_bases":["ČSN 73 6160, čl. 7.2, 7.3"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa asfaltowa Oznaczanie wytrzymałości połączenia i wskaźnika zagęszczenia warstw Asfaltová vrstva Stanovení pevnosti spojení a míry zhutnění vrstev ČSN 73 6160, čl. 7.2, 7.3 Warstwa asfaltowa Oznaczanie wytrzymalosci polaczenia i wskaznika zageszczenia warstw Asfaltova vrstva Stanoveni pevnosti spojeni a miry zhutneni vrstev CSN 73 6160, cl. 7.2, 7.3","search_en":"Asphalt layer Determination of the bond strength and degree of compaction ČSN 73 6160, čl. 7.2, 7.3","search_zh":"沥青层 层间粘结强度和压实度测定 ČSN 73 6160, čl. 7.2, 7.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a96feced5cd23b8a83e842ce","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"20","test_object":"Warstwa asfaltowa","test_object_en":"Asphalt layer","test_object_zh":"沥青层","test_object_cs":"Asfaltová vrstva","methodology":"Oznaczanie wytrzymałości połączenia i wskaźnika zagęszczenia warstw","methodology_en":"Determination of the bond strength and degree of compaction","methodology_zh":"层间粘结强度和压实度测定","methodology_cs":"Stanovení pevnosti spojení a míry zhutnění vrstev","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości połączenia i wskaźnika zagęszczenia warstw","reference":"ČSN 73 6160, čl. 7.2, 7.3","norm_bases":["ČSN 73 6160, čl. 7.2, 7.3"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa asfaltowa Oznaczanie wytrzymałości połączenia i wskaźnika zagęszczenia warstw Asfaltová vrstva Stanovení pevnosti spojení a míry zhutnění vrstev ČSN 73 6160, čl. 7.2, 7.3 Warstwa asfaltowa Oznaczanie wytrzymalosci polaczenia i wskaznika zageszczenia warstw Asfaltova vrstva Stanoveni pevnosti spojeni a miry zhutneni vrstev CSN 73 6160, cl. 7.2, 7.3","search_en":"Asphalt layer Determination of the bond strength and degree of compaction ČSN 73 6160, čl. 7.2, 7.3","search_zh":"沥青层 层间粘结强度和压实度测定 ČSN 73 6160, čl. 7.2, 7.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ba6168e6e3c1979440e561bc","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"21","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie sztywności – badanie dwupunktowego zginania","methodology_en":"Determination of stiffness - two-point bend test","methodology_zh":"劲度模量测定 – 两点弯曲试验","methodology_cs":"Stanovení tuhosti – zkouška dvoubodovým ohybem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sztywności – badanie dwupunktowego zginania","reference":"ČSN EN 12697-26+A1, příloha A","norm_bases":["ČSN EN 12697-26+A1, příloha A"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie sztywności – badanie dwupunktowego zginania Asfaltová směs Stanovení tuhosti – zkouška dvoubodovým ohybem ČSN EN 12697-26+A1, příloha A Mieszanka mineralno-asfaltowa Oznaczanie sztywnosci – badanie dwupunktowego zginania Asfaltova smes Stanoveni tuhosti – zkouska dvoubodovym ohybem CSN EN 12697-26+A1, priloha A","search_en":"Asphalt mixture Determination of stiffness - two-point bend test ČSN EN 12697-26+A1, příloha A","search_zh":"沥青混合料 劲度模量测定 – 两点弯曲试验 ČSN EN 12697-26+A1, příloha A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3f8041ba446ad3d3f4b71c1b","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"22","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie sztywności – badanie pośredniego rozciągania","methodology_en":"Determination of stiffness - indirect tensile test","methodology_zh":"劲度模量测定 – 间接拉伸试验","methodology_cs":"Stanovení tuhosti – zkouška v příčném tahu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sztywności – badanie pośredniego rozciągania","reference":"ČSN EN 12697-26+A1, příloha C","norm_bases":["ČSN EN 12697-26+A1, příloha C"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie sztywności – badanie pośredniego rozciągania Asfaltová směs Stanovení tuhosti – zkouška v příčném tahu ČSN EN 12697-26+A1, příloha C Mieszanka mineralno-asfaltowa Oznaczanie sztywnosci – badanie posredniego rozciagania Asfaltova smes Stanoveni tuhosti – zkouska v pricnem tahu CSN EN 12697-26+A1, priloha C","search_en":"Asphalt mixture Determination of stiffness - indirect tensile test ČSN EN 12697-26+A1, příloha C","search_zh":"沥青混合料 劲度模量测定 – 间接拉伸试验 ČSN EN 12697-26+A1, příloha C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"62d03621e0d4392f567f0098","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"23","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Badanie koleinowania – małe urządzenia badawcze","methodology_en":"Wheel tracking test – small-size devices","methodology_zh":"车辙试验 – 小型试验装置","methodology_cs":"Zkouška pojíždění kolem – malá zkušební zařízení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie koleinowania – małe urządzenia badawcze","reference":"ČSN EN 12697-22+A1, Postup B na vzduchu","norm_bases":["ČSN EN 12697-22+A1, Postup B na vzduchu"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Badanie koleinowania – małe urządzenia badawcze Asfaltová směs Zkouška pojíždění kolem – malá zkušební zařízení ČSN EN 12697-22+A1, Postup B na vzduchu Mieszanka mineralno-asfaltowa Badanie koleinowania – male urzadzenia badawcze Asfaltova smes Zkouska pojizdeni kolem – mala zkusebni zarizeni CSN EN 12697-22+A1, Postup B na vzduchu","search_en":"Asphalt mixture Wheel tracking test – small-size devices ČSN EN 12697-22+A1, Postup B na vzduchu","search_zh":"沥青混合料 车辙试验 – 小型试验装置 ČSN EN 12697-22+A1, Postup B na vzduchu","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fffaaa3c607910b77d003b41","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"24","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Przygotowanie próbek badawczych zagęszczarką płyt","methodology_en":"Specimen prepared by roller compactor","methodology_zh":"轮碾成型试件制备","methodology_cs":"Příprava zkušebních těles zhutňovačem desek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Przygotowanie próbek badawczych zagęszczarką płyt","reference":"ČSN EN 12697-33+A1, čl. 5.3 a 7.3","norm_bases":["ČSN EN 12697-33+A1, čl. 5.3 a 7.3"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Przygotowanie próbek badawczych zagęszczarką płyt Asfaltová směs Příprava zkušebních těles zhutňovačem desek ČSN EN 12697-33+A1, čl. 5.3 a 7.3 Mieszanka mineralno-asfaltowa Przygotowanie probek badawczych zageszczarka plyt Asfaltova smes Priprava zkusebnich teles zhutnovacem desek CSN EN 12697-33+A1, cl. 5.3 a 7.3","search_en":"Asphalt mixture Specimen prepared by roller compactor ČSN EN 12697-33+A1, čl. 5.3 a 7.3","search_zh":"沥青混合料 轮碾成型试件制备 ČSN EN 12697-33+A1, čl. 5.3 a 7.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bff3c61c690f3e908d9493c1","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"25","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie wytrzymałości na rozciąganie pośrednie","methodology_en":"Determination of indirect tensile strength","methodology_zh":"间接拉伸强度测定","methodology_cs":"Stanovení pevnosti v příčném tahu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na rozciąganie pośrednie","reference":"ČSN EN 12697-23","norm_bases":["ČSN EN 12697-23"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie wytrzymałości na rozciąganie pośrednie Asfaltová směs Stanovení pevnosti v příčném tahu ČSN EN 12697-23 Mieszanka mineralno-asfaltowa Oznaczanie wytrzymalosci na rozciaganie posrednie Asfaltova smes Stanoveni pevnosti v pricnem tahu CSN EN 12697-23","search_en":"Asphalt mixture Determination of indirect tensile strength ČSN EN 12697-23","search_zh":"沥青混合料 间接拉伸强度测定 ČSN EN 12697-23","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0bf434a116e0d0836ecf3eb0","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"26","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie wrażliwości próbek na działanie wody","methodology_en":"Determination of the water sensitivity","methodology_zh":"试件水敏感性测定","methodology_cs":"Stanovení odolnosti zkušebního tělesa vůči vodě","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wrażliwości próbek na działanie wody","reference":"ČSN EN 12697-12, metoda A","norm_bases":["ČSN EN 12697-12, metoda A"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Oznaczanie wrażliwości próbek na działanie wody Asfaltová směs Stanovení odolnosti zkušebního tělesa vůči vodě ČSN EN 12697-12, metoda A Mieszanka mineralno-asfaltowa Oznaczanie wrazliwosci probek na dzialanie wody Asfaltova smes Stanoveni odolnosti zkusebniho telesa vuci vode CSN EN 12697-12, metoda A","search_en":"Asphalt mixture Determination of the water sensitivity ČSN EN 12697-12, metoda A","search_zh":"沥青混合料 试件水敏感性测定 ČSN EN 12697-12, metoda A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"290ec862f4f82796448187e5","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"27","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Przygotowanie próbek badawczych ubijakiem udarowym","methodology_en":"Specimen preparation by impact compactor","methodology_zh":"击实法试件制备","methodology_cs":"Příprava zkušebních těles rázovým zhutňovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Przygotowanie próbek badawczych ubijakiem udarowym","reference":"ČSN EN 12697-30","norm_bases":["ČSN EN 12697-30"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Przygotowanie próbek badawczych ubijakiem udarowym Asfaltová směs Příprava zkušebních těles rázovým zhutňovačem ČSN EN 12697-30 Mieszanka mineralno-asfaltowa Przygotowanie probek badawczych ubijakiem udarowym Asfaltova smes Priprava zkusebnich teles razovym zhutnovacem CSN EN 12697-30","search_en":"Asphalt mixture Specimen preparation by impact compactor ČSN EN 12697-30","search_zh":"沥青混合料 击实法试件制备 ČSN EN 12697-30","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"beea32cc062cda4d52cdcfe7","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"28","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie składu ziarnowego – metoda przesiewania","methodology_en":"Determination of particle size distribution - Sieving method","methodology_zh":"粒度分布测定 – 筛分法","methodology_cs":"Stanovení zrnitosti – sítový rozbor","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie składu ziarnowego – metoda przesiewania","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie składu ziarnowego – metoda przesiewania Kamenivo Stanovení zrnitosti – sítový rozbor ČSN EN 933-1 Kruszywo Oznaczanie skladu ziarnowego – metoda przesiewania Kamenivo Stanoveni zrnitosti – sitovy rozbor CSN EN 933-1","search_en":"Aggregates Determination of particle size distribution - Sieving method ČSN EN 933-1","search_zh":"集料 粒度分布测定 – 筛分法 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f7d803fc9b0625712de95351","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"29","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie kształtu ziaren – wskaźnik kształtu","methodology_en":"Determination of particle shape - Shape index","methodology_zh":"颗粒形状测定 – 形状指数","methodology_cs":"Stanovení tvaru zrn – tvarový index","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kształtu ziaren – wskaźnik kształtu","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie kształtu ziaren – wskaźnik kształtu Kamenivo Stanovení tvaru zrn – tvarový index ČSN EN 933-4 Kruszywo Oznaczanie ksztaltu ziaren – wskaznik ksztaltu Kamenivo Stanoveni tvaru zrn – tvarovy index CSN EN 933-4","search_en":"Aggregates Determination of particle shape - Shape index ČSN EN 933-4","search_zh":"集料 颗粒形状测定 – 形状指数 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d9bf139e76d6376620485ebb","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"30","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności przez suszenie w suszarce","methodology_en":"Determination of the water content by drying in a ventilated oven","methodology_zh":"烘箱干燥法含水率测定","methodology_cs":"Stanovení vlhkosti sušením v sušárně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności przez suszenie w suszarce","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności przez suszenie w suszarce Kamenivo Stanovení vlhkosti sušením v sušárně ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci przez suszenie w suszarce Kamenivo Stanoveni vlhkosti susenim v susarne CSN EN 1097-5","search_en":"Aggregates Determination of the water content by drying in a ventilated oven ČSN EN 1097-5","search_zh":"集料 烘箱干燥法含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a40c01566da4bdb52125c2a7","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"31","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Ocena pyłów – badanie wskaźnika piaskowego","methodology_en":"Assessment of fines - Sand equivalent test","methodology_zh":"细粒评定 – 砂当量试验","methodology_cs":"Posouzení jemných částic – zkouška ekvivalentu písku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ocena pyłów – badanie wskaźnika piaskowego","reference":"ČSN EN 933-8+A1","norm_bases":["ČSN EN 933-8+A1"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Ocena pyłów – badanie wskaźnika piaskowego Kamenivo Posouzení jemných částic – zkouška ekvivalentu písku ČSN EN 933-8+A1 Kruszywo Ocena pylow – badanie wskaznika piaskowego Kamenivo Posouzeni jemnych castic – zkouska ekvivalentu pisku CSN EN 933-8+A1","search_en":"Aggregates Assessment of fines - Sand equivalent test ČSN EN 933-8+A1","search_zh":"集料 细粒评定 – 砂当量试验 ČSN EN 933-8+A1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3048f232a99b959a2309197f","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"32","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Ocena pyłów – badanie błękitem metylenowym","methodology_en":"Assessment of fines - Methylene blue test","methodology_zh":"细粒评定 – 亚甲蓝试验","methodology_cs":"Posouzení jemných částic – zkouška methylenovou modří","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ocena pyłów – badanie błękitem metylenowym","reference":"ČSN EN 933-9","norm_bases":["ČSN EN 933-9"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Ocena pyłów – badanie błękitem metylenowym Kamenivo Posouzení jemných částic – zkouška methylenovou modří ČSN EN 933-9 Kruszywo Ocena pylow – badanie blekitem metylenowym Kamenivo Posouzeni jemnych castic – zkouska methylenovou modri CSN EN 933-9","search_en":"Aggregates Assessment of fines - Methylene blue test ČSN EN 933-9","search_zh":"集料 细粒评定 – 亚甲蓝试验 ČSN EN 933-9","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a573d22cb710dc833b959393","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"33","test_object":"Asfalty i lepiszcza asfaltowe","test_object_en":"Bitumen and bituminous binders","test_object_zh":"沥青和沥青结合料","test_object_cs":"Asfalty a asfaltová pojiva","methodology":"Oznaczanie penetracji igłą","methodology_en":"Determination of needle penetration","methodology_zh":"针入度测定","methodology_cs":"Stanovení penetrace jehlou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie penetracji igłą","reference":"ČSN EN 1426","norm_bases":["ČSN EN 1426"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Asfalty i lepiszcza asfaltowe Oznaczanie penetracji igłą Asfalty a asfaltová pojiva Stanovení penetrace jehlou ČSN EN 1426 Asfalty i lepiszcza asfaltowe Oznaczanie penetracji igla Asfalty a asfaltova pojiva Stanoveni penetrace jehlou CSN EN 1426","search_en":"Bitumen and bituminous binders Determination of needle penetration ČSN EN 1426","search_zh":"沥青和沥青结合料 针入度测定 ČSN EN 1426","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e26e2d7d94b3d58ff7a01ebe","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"34","test_object":"Asfalty i lepiszcza asfaltowe","test_object_en":"Bitumen and bituminous binders","test_object_zh":"沥青和沥青结合料","test_object_cs":"Asfalty a asfaltová pojiva","methodology":"Oznaczanie temperatury mięknienia – metoda Pierścień i Kula","methodology_en":"Determination of the softening point - Ring and Ball method","methodology_zh":"软化点测定 – 环球法","methodology_cs":"Stanovení bodu měknutí – metoda kroužek a kulička","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury mięknienia – metoda Pierścień i Kula","reference":"ČSN EN 1427","norm_bases":["ČSN EN 1427"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Asfalty i lepiszcza asfaltowe Oznaczanie temperatury mięknienia – metoda Pierścień i Kula Asfalty a asfaltová pojiva Stanovení bodu měknutí – metoda kroužek a kulička ČSN EN 1427 Asfalty i lepiszcza asfaltowe Oznaczanie temperatury mieknienia – metoda Pierscien i Kula Asfalty a asfaltova pojiva Stanoveni bodu meknuti – metoda krouzek a kulicka CSN EN 1427","search_en":"Bitumen and bituminous binders Determination of the softening point - Ring and Ball method ČSN EN 1427","search_zh":"沥青和沥青结合料 软化点测定 – 环球法 ČSN EN 1427","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"feecfb96c8204f638c54fad0","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"35","test_object":"Grunty i materiały sypkie","test_object_en":"Soils and backfills","test_object_zh":"土和散体材料","test_object_cs":"Zeminy a sypaniny","methodology":"Badanie obciążeniem statycznym","methodology_en":"Static loading test","methodology_zh":"静载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie obciążeniem statycznym","reference":"ČSN 72 1006, příloha A, B, D; ČSN 73 6190","norm_bases":["ČSN 72 1006, příloha A, B, D","ČSN 73 6190"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty i materiały sypkie Badanie obciążeniem statycznym Zeminy a sypaniny Statická zatěžovací zkouška ČSN 72 1006, příloha A, B, D; ČSN 73 6190 Grunty i materialy sypkie Badanie obciazeniem statycznym Zeminy a sypaniny Staticka zatezovaci zkouska CSN 72 1006, priloha A, B, D; CSN 73 6190","search_en":"Soils and backfills Static loading test ČSN 72 1006, příloha A, B, D; ČSN 73 6190","search_zh":"土和散体材料 静载试验 ČSN 72 1006, příloha A, B, D; ČSN 73 6190","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c07e403768b171841bba97a8","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"36","test_object":"Grunty i materiały sypkie","test_object_en":"Soils and backfills","test_object_zh":"土和散体材料","test_object_cs":"Zeminy a sypaniny","methodology":"Badanie obciążeniem udarowym lekką płytą dynamiczną","methodology_en":"Impact loading test by light dynamic plate","methodology_zh":"轻型动力板冲击荷载试验","methodology_cs":"Rázová zatěžovací zkouška lehkou dynamickou deskou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie obciążeniem udarowym lekką płytą dynamiczną","reference":"ČSN 73 6192, čl. 3.1.3, 4.4, 5.3, 5.4, 6.2, 6.3","norm_bases":["ČSN 73 6192, čl. 3.1.3, 4.4, 5.3, 5.4, 6.2, 6.3"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty i materiały sypkie Badanie obciążeniem udarowym lekką płytą dynamiczną Zeminy a sypaniny Rázová zatěžovací zkouška lehkou dynamickou deskou ČSN 73 6192, čl. 3.1.3, 4.4, 5.3, 5.4, 6.2, 6.3 Grunty i materialy sypkie Badanie obciazeniem udarowym lekka plyta dynamiczna Zeminy a sypaniny Razova zatezovaci zkouska lehkou dynamickou deskou CSN 73 6192, cl. 3.1.3, 4.4, 5.3, 5.4, 6.2, 6.3","search_en":"Soils and backfills Impact loading test by light dynamic plate ČSN 73 6192, čl. 3.1.3, 4.4, 5.3, 5.4, 6.2, 6.3","search_zh":"土和散体材料 轻型动力板冲击荷载试验 ČSN 73 6192, čl. 3.1.3, 4.4, 5.3, 5.4, 6.2, 6.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c47367612297950551aed7a","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"37","test_object":"Gotowe warstwy nawierzchni","test_object_en":"Pavement courses","test_object_zh":"路面成品层","test_object_cs":"Hotové vrstvy vozovky","methodology":"Oznaczanie wskaźnika zagęszczenia metodą nieniszczącą","methodology_en":"Determination of the degree of compaction by non-destructive methods","methodology_zh":"无损法压实度测定","methodology_cs":"Stanovení míry zhutnění nedestruktivně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika zagęszczenia metodą nieniszczącą","reference":"ČSN 73 6160, čl. 7.2, metoda B","norm_bases":["ČSN 73 6160, čl. 7.2, metoda B"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gotowe warstwy nawierzchni Oznaczanie wskaźnika zagęszczenia metodą nieniszczącą Hotové vrstvy vozovky Stanovení míry zhutnění nedestruktivně ČSN 73 6160, čl. 7.2, metoda B Gotowe warstwy nawierzchni Oznaczanie wskaznika zageszczenia metoda nieniszczaca Hotove vrstvy vozovky Stanoveni miry zhutneni nedestruktivne CSN 73 6160, cl. 7.2, metoda B","search_en":"Pavement courses Determination of the degree of compaction by non-destructive methods ČSN 73 6160, čl. 7.2, metoda B","search_zh":"路面成品层 无损法压实度测定 ČSN 73 6160, čl. 7.2, metoda B","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"63628d993b86c69282d720de","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"38","test_object":"Gotowe warstwy nawierzchni","test_object_en":"Pavement courses","test_object_zh":"路面成品层","test_object_cs":"Hotové vrstvy vozovky","methodology":"Pomiar nierówności powierzchni łatą","methodology_en":"Irregularity measurement by check bar","methodology_zh":"直尺法表面平整度测量","methodology_cs":"Měření nerovnosti povrchu latí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar nierówności powierzchni łatą","reference":"ČSN 73 6175, čl. 8","norm_bases":["ČSN 73 6175, čl. 8"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gotowe warstwy nawierzchni Pomiar nierówności powierzchni łatą Hotové vrstvy vozovky Měření nerovnosti povrchu latí ČSN 73 6175, čl. 8 Gotowe warstwy nawierzchni Pomiar nierownosci powierzchni lata Hotove vrstvy vozovky Mereni nerovnosti povrchu lati CSN 73 6175, cl. 8","search_en":"Pavement courses Irregularity measurement by check bar ČSN 73 6175, čl. 8","search_zh":"路面成品层 直尺法表面平整度测量 ČSN 73 6175, čl. 8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14d76c14320a943dc19dbdd8","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"39","test_object":"Powierzchnie nawierzchni drogowych i konstrukcji","test_object_en":"Surfaces of pavements and structures","test_object_zh":"路面和结构表面","test_object_cs":"Povrchy vozovek a konstrukcí","methodology":"Oznaczanie głębokości makrotekstury metodą objętościową","methodology_en":"Measurement of macrotexture depth by volumetric method","methodology_zh":"体积法宏观构造深度测定","methodology_cs":"Stanovení hloubky makrotextury odměrnou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości makrotekstury metodą objętościową","reference":"ČSN EN 13036-1","norm_bases":["ČSN EN 13036-1"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powierzchnie nawierzchni drogowych i konstrukcji Oznaczanie głębokości makrotekstury metodą objętościową Povrchy vozovek a konstrukcí Stanovení hloubky makrotextury odměrnou metodou ČSN EN 13036-1 Powierzchnie nawierzchni drogowych i konstrukcji Oznaczanie glebokosci makrotekstury metoda objetosciowa Povrchy vozovek a konstrukci Stanoveni hloubky makrotextury odmernou metodou CSN EN 13036-1","search_en":"Surfaces of pavements and structures Measurement of macrotexture depth by volumetric method ČSN EN 13036-1","search_zh":"路面和结构表面 体积法宏观构造深度测定 ČSN EN 13036-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a2229ae52b1ebdb334f2c20","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"40","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"粒度分布测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN ISO 17892-4, mimo čl. 5.4","norm_bases":["ČSN EN ISO 17892-4, mimo čl. 5.4"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie uziarnienia Zeminy Stanovení zrnitosti ČSN EN ISO 17892-4, mimo čl. 5.4 Grunty Oznaczanie uziarnienia Zeminy Stanoveni zrnitosti CSN EN ISO 17892-4, mimo cl. 5.4","search_en":"Soils Determination of particle size distribution ČSN EN ISO 17892-4, mimo čl. 5.4","search_zh":"土 粒度分布测定 ČSN EN ISO 17892-4, mimo čl. 5.4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ad600966ce87bc6cb0f792b","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"41","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie granic konsystencji","methodology_en":"Determination of liquid and plastic limits","methodology_zh":"液限和塑限测定","methodology_cs":"Stanovení konzistenčních mezí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie granic konsystencji","reference":"ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3","norm_bases":["ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie granic konsystencji Zeminy Stanovení konzistenčních mezí ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3 Grunty Oznaczanie granic konsystencji Zeminy Stanoveni konzistencnich mezi CSN EN ISO 17892-12, mimo cl. 4.3, 5.4, 6.3","search_en":"Soils Determination of liquid and plastic limits ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3","search_zh":"土 液限和塑限测定 ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f876bfa00bae838bb21a0ede","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"42","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN ISO 17892-1","norm_bases":["ČSN EN ISO 17892-1"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wilgotności Zeminy Stanovení vlhkosti ČSN EN ISO 17892-1 Grunty Oznaczanie wilgotnosci Zeminy Stanoveni vlhkosti CSN EN ISO 17892-1","search_en":"Soils Determination of water content ČSN EN ISO 17892-1","search_zh":"土 含水率测定 ČSN EN ISO 17892-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4886435442ac1c6cbed97fac","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"1","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Pobieranie próbek betonu świeżego, pobór ręczny","methodology_en":"Sampling of fresh concrete, manual sampling","methodology_zh":"新拌混凝土取样，人工取样","methodology_cs":"Odběr vzorků čerstvého betonu manuální odběr","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek betonu świeżego, pobór ręczny","reference":"ČSN EN 12350-1","norm_bases":["ČSN EN 12350-1"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Pobieranie próbek betonu świeżego, pobór ręczny Čerstvý beton Odběr vzorků čerstvého betonu manuální odběr ČSN EN 12350-1 Beton swiezy Pobieranie probek betonu swiezego, pobor reczny Cerstvy beton Odber vzorku cerstveho betonu manualni odber CSN EN 12350-1","search_en":"Fresh concrete Sampling of fresh concrete, manual sampling ČSN EN 12350-1","search_zh":"新拌混凝土 新拌混凝土取样，人工取样 ČSN EN 12350-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"35f08689bbc355099b698079","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"1","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Pobieranie próbek betonu świeżego, pobór ręczny","methodology_en":"Sampling of fresh concrete, manual sampling","methodology_zh":"新拌混凝土取样，人工取样","methodology_cs":"Odběr vzorků čerstvého betonu manuální odběr","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek betonu świeżego, pobór ręczny","reference":"ČSN EN 12350-1","norm_bases":["ČSN EN 12350-1"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Pobieranie próbek betonu świeżego, pobór ręczny Čerstvý beton Odběr vzorků čerstvého betonu manuální odběr ČSN EN 12350-1 Beton swiezy Pobieranie probek betonu swiezego, pobor reczny Cerstvy beton Odber vzorku cerstveho betonu manualni odber CSN EN 12350-1","search_en":"Fresh concrete Sampling of fresh concrete, manual sampling ČSN EN 12350-1","search_zh":"新拌混凝土 新拌混凝土取样，人工取样 ČSN EN 12350-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50192057e673107da3cfc189","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"2","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Pobieranie próbek betonu stwardniałego (odwiertów z konstrukcji)","methodology_en":"Sampling of hardened concrete (cored specimens of structures)","methodology_zh":"硬化混凝土取样（结构钻芯）","methodology_cs":"Odběr vzorků ztvrdlého betonu (vývrtů z konstrukce)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek betonu stwardniałego (odwiertów z konstrukcji)","reference":"ČSN EN 12504-1, čl. 6","norm_bases":["ČSN EN 12504-1, čl. 6"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Pobieranie próbek betonu stwardniałego (odwiertów z konstrukcji) Ztvrdlý beton Odběr vzorků ztvrdlého betonu (vývrtů z konstrukce) ČSN EN 12504-1, čl. 6 Beton stwardnialy Pobieranie probek betonu stwardnialego (odwiertow z konstrukcji) Ztvrdly beton Odber vzorku ztvrdleho betonu (vyvrtu z konstrukce) CSN EN 12504-1, cl. 6","search_en":"Hardened concrete Sampling of hardened concrete (cored specimens of structures) ČSN EN 12504-1, čl. 6","search_zh":"硬化混凝土 硬化混凝土取样（结构钻芯） ČSN EN 12504-1, čl. 6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f3bea2168e93321e8d618b46","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"2","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Pobieranie próbek betonu stwardniałego (odwiertów z konstrukcji)","methodology_en":"Sampling of hardened concrete (cored specimens of structures)","methodology_zh":"硬化混凝土取样（结构钻芯）","methodology_cs":"Odběr vzorků ztvrdlého betonu (vývrtů z konstrukce)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek betonu stwardniałego (odwiertów z konstrukcji)","reference":"ČSN EN 12504-1, čl. 6","norm_bases":["ČSN EN 12504-1, čl. 6"],"lab_section":"Zachód","lab_section_en":"Západ","lab_section_zh":"西区","lab_section_cs":"Západ","lab_address":"Vrbice 67, 364 52 Žlutice","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Pobieranie próbek betonu stwardniałego (odwiertów z konstrukcji) Ztvrdlý beton Odběr vzorků ztvrdlého betonu (vývrtů z konstrukce) ČSN EN 12504-1, čl. 6 Beton stwardnialy Pobieranie probek betonu stwardnialego (odwiertow z konstrukcji) Ztvrdly beton Odber vzorku ztvrdleho betonu (vyvrtu z konstrukce) CSN EN 12504-1, cl. 6","search_en":"Hardened concrete Sampling of hardened concrete (cored specimens of structures) ČSN EN 12504-1, čl. 6","search_zh":"硬化混凝土 硬化混凝土取样（结构钻芯） ČSN EN 12504-1, čl. 6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"754514d36a494b2ff411e895","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"3","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Pobieranie próbek mieszanki mineralno-asfaltowej","methodology_en":"Asphalt mixture sampling","methodology_zh":"沥青混合料取样","methodology_cs":"Odběr vzorků asfaltové směsi","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek mieszanki mineralno-asfaltowej","reference":"ČSN EN 12697-27, čl. 4.1, 4.3, 4.7","norm_bases":["ČSN EN 12697-27, čl. 4.1, 4.3, 4.7"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Pobieranie próbek mieszanki mineralno-asfaltowej Asfaltová směs Odběr vzorků asfaltové směsi ČSN EN 12697-27, čl. 4.1, 4.3, 4.7 Mieszanka mineralno-asfaltowa Pobieranie probek mieszanki mineralno-asfaltowej Asfaltova smes Odber vzorku asfaltove smesi CSN EN 12697-27, cl. 4.1, 4.3, 4.7","search_en":"Asphalt mixture Asphalt mixture sampling ČSN EN 12697-27, čl. 4.1, 4.3, 4.7","search_zh":"沥青混合料 沥青混合料取样 ČSN EN 12697-27, čl. 4.1, 4.3, 4.7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c782c95d5376f55fe656583f","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"3","test_object":"Mieszanka mineralno-asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Pobieranie próbek mieszanki mineralno-asfaltowej","methodology_en":"Asphalt mixture sampling","methodology_zh":"沥青混合料取样","methodology_cs":"Odběr vzorků asfaltové směsi","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek mieszanki mineralno-asfaltowej","reference":"ČSN EN 12697-27, čl. 4.1, 4.3, 4.7","norm_bases":["ČSN EN 12697-27, čl. 4.1, 4.3, 4.7"],"lab_section":"Znojmo","lab_section_en":"Znojmo","lab_section_zh":"兹诺伊莫","lab_section_cs":"Znojmo","lab_address":"Dyje ev.č. 511, 669 02 Znojmo","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka mineralno-asfaltowa Pobieranie próbek mieszanki mineralno-asfaltowej Asfaltová směs Odběr vzorků asfaltové směsi ČSN EN 12697-27, čl. 4.1, 4.3, 4.7 Mieszanka mineralno-asfaltowa Pobieranie probek mieszanki mineralno-asfaltowej Asfaltova smes Odber vzorku asfaltove smesi CSN EN 12697-27, cl. 4.1, 4.3, 4.7","search_en":"Asphalt mixture Asphalt mixture sampling ČSN EN 12697-27, čl. 4.1, 4.3, 4.7","search_zh":"沥青混合料 沥青混合料取样 ČSN EN 12697-27, čl. 4.1, 4.3, 4.7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5015eb013a89bb05743f6c24","lab_id":"69ad52a4de79e566650fd5bc","country":"CZ","accr_number":"1780","accr_body":"ČIA","row_label":"4","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Pobieranie próbek kruszywa","methodology_en":"Sampling of aggregates","methodology_zh":"集料取样","methodology_cs":"Odběr vzorků kameniva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek kruszywa","reference":"ČSN EN 932-1, čl. 8.2, 8.8, 8.9","norm_bases":["ČSN EN 932-1, čl. 8.2, 8.8, 8.9"],"lab_section":"Jihlava","lab_section_en":"Jihlava","lab_section_zh":"伊赫拉瓦","lab_section_cs":"Jihlava","lab_address":"Kosovská 10, 586 37 Jihlava","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Pobieranie próbek kruszywa Kamenivo Odběr vzorků kameniva ČSN EN 932-1, čl. 8.2, 8.8, 8.9 Kruszywo Pobieranie probek kruszywa Kamenivo Odber vzorku kameniva CSN EN 932-1, cl. 8.2, 8.8, 8.9","search_en":"Aggregates Sampling of aggregates ČSN EN 932-1, čl. 8.2, 8.8, 8.9","search_zh":"集料 集料取样 ČSN EN 932-1, čl. 8.2, 8.8, 8.9","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}