{"lab":{"_id":"69ad52a4de79e566650fd59e","accr_number":"1761","country":"CZ","accr_body":"ČIA","address":"Mojmírovo náměstí 16, 612 00 Brno","categories":["water","microbiology","environment"],"city":"Brno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":48,"name":"Výzkumný ústav vodohospodářský T. G. Masaryka, veřejná výzkumná instituce","parse_status":"parsed","parse_version":5,"pdf_files":["1761_494_2025_CS.pdf","1761_494_2025_EN.pdf"],"scope_summary":"Analizy chemiczne wód, wyciągów wodnych, ekstraktów do n-heptanu, osadów dennych, zawiesin rzecznych, biomasy, gruntów i osadów; analizy mikrobiologiczne wód; analizy hydrobiologiczne wód i peryfitonu; oznaczanie mikroplastików, pobieranie próbek wód przeznaczonych do spożycia, powierzchniowych i ścieków, w zakresie określonym w załączniku do świadectwa.","search_text":"výzkumný ústav vodohospodářský t. g. masaryka, veřejná výzkumná instituce mojmírovo náměstí 16, 612 00 brno 1761","status":"active","updated_at":"2026-03-08T14:52:16.045Z","valid_from":"","valid_until":"26-10-2028","website":"www.vuv.cz","location":{"type":"Point","coordinates":[16.6068,49.1951]},"email_confidence":"high","email_mx":true,"email_source":"https://www.vuv.cz","map_coord":[49.224315,16.596724],"map_geo":"nominatim-street","certificate_date":"30.09.2025","certificate_no":"494/2025","certificate_replaces":"103/2025 z 04.03.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analizy chemiczne wód, wyciągów wodnych, ekstraktów do n-heptanu, osadów dennych, zawiesin rzecznych, biomasy, gruntów i osadów; analizy mikrobiologiczne wód; analizy hydrobiologiczne wód i peryfitonu; oznaczanie mikroplastików, pobieranie próbek wód przeznaczonych do spożycia, powierzchniowych i ścieków, w zakresie określonym w załączniku do świadectwa.","en":"Chemical analyses of water, aqueous extracts, n-heptane extracts, sediments, suspended sediments, biomass, soils and sludges; microbiological analyses of water; hydrobiological analyses of water and periphyton; determination of microplastics, sampling of drinking, surface and waste water, as specified in the appendix to this certificate.","zh":"水、水浸出液、正庚烷提取物、沉积物、悬移质、生物质、土壤和污泥的化学分析；水的微生物分析；水和附着生物的水生生物分析；微塑料测定；饮用水、地表水和废水采样，范围见本证书附件。","cs":"Chemické analýzy vod, vodných výluhů, extraktů do n-heptanu, sedimentů, plavenin, biomasy, zemin a kalů; mikrobiologické analýzy vod; hydrobiologické analýzy vod a nárostů; stanovení mikroplastů, vzorkování pitných, povrchových a odpadních vod, vymezené přílohou tohoto osvědčení."}],"flexible_scope":true,"flexible_scope_url":"https://www.vuv.cz/laboratorni-sluzby/certifikace/","has_en":true,"has_zh":true,"lab_division":"Dział Laboratoriów VÚV TGM v.v.i., oddział Brno","lab_division_cs":"Oddělení laboratoří VÚV TGM v.v.i., pobočka Brno","lab_division_en":"Laboratory Department of VÚV TGM v.v.i., Brno branch","lab_division_zh":"VÚV TGM实验室部（布尔诺分部）","lab_locations":[{"code":null,"name":"Výzkumný ústav vodohospodářský T. G. Masaryka, veřejná výzkumná instituce","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":true,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"},{"code":null,"name":"Dział hydrochemii","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":false,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"},{"code":null,"name":"Dział hydrobiologii","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":false,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"}],"lab_locations_en":[{"code":null,"name":"Výzkumný ústav vodohospodářský T. G. Masaryka, veřejná výzkumná instituce","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":true,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"},{"code":null,"name":"Hydrochemistry Department","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":false,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"},{"code":null,"name":"Hydrobiology Department","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":false,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"}],"lab_locations_zh":[{"code":null,"name":"Výzkumný ústav vodohospodářský T. G. Masaryka, veřejná výzkumná instituce","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":true,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"},{"code":null,"name":"水化学部","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":false,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"},{"code":null,"name":"水生生物学部","street":"Mojmírovo náměstí 16","postal_code":"612 00","city":"Brno","is_hq":false,"address":"Mojmírovo náměstí 16, 612 00 Brno","site":"61200|mojmírovonáměstí16"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"ZCHR, SAA, SOA, MBI, HB, MB, OV","pl":"oznaczenia procedur wewnętrznych odpowiadających standardowym procedurom operacyjnym","en":"designations of internal procedures corresponding to standard operating procedures","zh":"对应标准操作程序的内部程序代号","cs":"označení interních postupů odpovídajících standardním operačním postupům"},{"abbr":"GC/FID","pl":"chromatografia gazowa z detektorem płomieniowo-jonizacyjnym","en":"gas chromatography with flame ionization detector","zh":"气相色谱-火焰离子化检测器","cs":"plynová chromatografie s plamenoionizačním detektorem"},{"abbr":"ICP-MS","pl":"spektrometria mas z plazmą indukcyjnie sprzężoną","en":"inductively coupled plasma mass spectrometry","zh":"电感耦合等离子体质谱","cs":"hmotnostní spektrometrie s indukčně vázaným plazmatem"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立开展采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"a65499be50b2fc12f127406d981818ad7a9c9552d1b6c92c11e82e9e355f360d","source_pdf_url":"https://www.cai.cz/OA/pdf/494_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"8831b0f31033a05b7c6f3d2c","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.1","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"ZCHR-33 (ČSN 75 7342)","norm_bases":["ZCHR-33","ČSN 75 7342"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie temperatury Pitné, povrchové, podzemní, odpadní vody Stanovení teploty ZCHR-33 (ČSN 75 7342) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie temperatury Pitne, povrchove, podzemni, odpadni vody Stanoveni teploty ZCHR-33 (CSN 75 7342)","search_en":"Drinking, surface, ground and waste water Determination of temperature ZCHR-33 (ČSN 75 7342)","search_zh":"饮用水、地表水、地下水、废水 温度测定 ZCHR-33 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"082bd0821c4debef8e8e025f","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.1","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"ZCHR-33 (ČSN 75 7342)","norm_bases":["ZCHR-33","ČSN 75 7342"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie temperatury Pitné, povrchové, podzemní, odpadní vody Stanovení teploty ZCHR-33 (ČSN 75 7342) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie temperatury Pitne, povrchove, podzemni, odpadni vody Stanoveni teploty ZCHR-33 (CSN 75 7342)","search_en":"Drinking, surface, ground and waste water Determination of temperature ZCHR-33 (ČSN 75 7342)","search_zh":"饮用水、地表水、地下水、废水 温度测定 ZCHR-33 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5335f7329515de6c7dbb3481","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.2","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"ZCHR-01 (ČSN EN 27888)","norm_bases":["ZCHR-01","ČSN EN 27888"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie przewodności elektrycznej właściwej Pitné, povrchové, podzemní, odpadní vody Stanovení elektrické konduktivity ZCHR-01 (ČSN EN 27888) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie przewodnosci elektrycznej wlasciwej Pitne, povrchove, podzemni, odpadni vody Stanoveni elektricke konduktivity ZCHR-01 (CSN EN 27888)","search_en":"Drinking, surface, ground and waste water Determination of electrical conductivity ZCHR-01 (ČSN EN 27888)","search_zh":"饮用水、地表水、地下水、废水 电导率测定 ZCHR-01 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b94b92aea7bdbda662b4d13","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.2","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"ZCHR-01 (ČSN EN 27888)","norm_bases":["ZCHR-01","ČSN EN 27888"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie przewodności elektrycznej właściwej Pitné, povrchové, podzemní, odpadní vody Stanovení elektrické konduktivity ZCHR-01 (ČSN EN 27888) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie przewodnosci elektrycznej wlasciwej Pitne, povrchove, podzemni, odpadni vody Stanoveni elektricke konduktivity ZCHR-01 (CSN EN 27888)","search_en":"Drinking, surface, ground and waste water Determination of electrical conductivity ZCHR-01 (ČSN EN 27888)","search_zh":"饮用水、地表水、地下水、废水 电导率测定 ZCHR-01 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5e58a6b1fe8162875c1e4be2","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.3","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny","test_object_en":"Drinking, surface, ground and waste water, aqueous extract","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodný výluh","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH potentiometrically","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"ZCHR-02 (ČSN ISO 10523)","norm_bases":["ZCHR-02","ČSN ISO 10523"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny Oznaczanie pH metodą potencjometryczną Pitné, povrchové, podzemní, odpadní vody, vodný výluh Stanovení pH potenciometricky ZCHR-02 (ČSN ISO 10523) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciag wodny Oznaczanie pH metoda potencjometryczna Pitne, povrchove, podzemni, odpadni vody, vodny vyluh Stanoveni pH potenciometricky ZCHR-02 (CSN ISO 10523)","search_en":"Drinking, surface, ground and waste water, aqueous extract Determination of pH potentiometrically ZCHR-02 (ČSN ISO 10523)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 电位法测定pH ZCHR-02 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0e2b91f0114816780c144e38","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.3","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny","test_object_en":"Drinking, surface, ground and waste water, aqueous extract","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodný výluh","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH potentiometrically","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"ZCHR-02 (ČSN ISO 10523)","norm_bases":["ZCHR-02","ČSN ISO 10523"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny Oznaczanie pH metodą potencjometryczną Pitné, povrchové, podzemní, odpadní vody, vodný výluh Stanovení pH potenciometricky ZCHR-02 (ČSN ISO 10523) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciag wodny Oznaczanie pH metoda potencjometryczna Pitne, povrchove, podzemni, odpadni vody, vodny vyluh Stanoveni pH potenciometricky ZCHR-02 (CSN ISO 10523)","search_en":"Drinking, surface, ground and waste water, aqueous extract Determination of pH potentiometrically ZCHR-02 (ČSN ISO 10523)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 电位法测定pH ZCHR-02 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b797884688a6f190c8ec69a","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.4","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie tlenu rozpuszczonego metodą LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartości zmierzonych","methodology_en":"Determination of dissolved oxygen by the LDO method (luminescence) and % saturation by calculation from measured values","methodology_zh":"LDO（发光）法测定溶解氧，根据测量值计算饱和度%","methodology_cs":"Stanovení rozpuštěného kyslíku metodou LDO (luminiscenčně) a % nasycení výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego metodą LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartości zmierzonych","reference":"ZCHR-03 (ČSN ISO 17289)","norm_bases":["ZCHR-03","ČSN ISO 17289"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie tlenu rozpuszczonego metodą LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartości zmierzonych Pitné, povrchové, podzemní, odpadní vody Stanovení rozpuštěného kyslíku metodou LDO (luminiscenčně) a % nasycení výpočtem z naměřených hodnot ZCHR-03 (ČSN ISO 17289) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie tlenu rozpuszczonego metoda LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartosci zmierzonych Pitne, povrchove, podzemni, odpadni vody Stanoveni rozpusteneho kysliku metodou LDO (luminiscencne) a % nasyceni vypoctem z namerenych hodnot ZCHR-03 (CSN ISO 17289)","search_en":"Drinking, surface, ground and waste water Determination of dissolved oxygen by the LDO method (luminescence) and % saturation by calculation from measured values ZCHR-03 (ČSN ISO 17289)","search_zh":"饮用水、地表水、地下水、废水 LDO（发光）法测定溶解氧，根据测量值计算饱和度% ZCHR-03 (ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cbc7524fadc7958a187500ad","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.4","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie tlenu rozpuszczonego metodą LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartości zmierzonych","methodology_en":"Determination of dissolved oxygen by the LDO method (luminescence) and % saturation by calculation from measured values","methodology_zh":"LDO（发光）法测定溶解氧，根据测量值计算饱和度%","methodology_cs":"Stanovení rozpuštěného kyslíku metodou LDO (luminiscenčně) a % nasycení výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego metodą LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartości zmierzonych","reference":"ZCHR-03 (ČSN ISO 17289)","norm_bases":["ZCHR-03","ČSN ISO 17289"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie tlenu rozpuszczonego metodą LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartości zmierzonych Pitné, povrchové, podzemní, odpadní vody Stanovení rozpuštěného kyslíku metodou LDO (luminiscenčně) a % nasycení výpočtem z naměřených hodnot ZCHR-03 (ČSN ISO 17289) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie tlenu rozpuszczonego metoda LDO (luminescencyjnie) i % nasycenia obliczeniowo z wartosci zmierzonych Pitne, povrchove, podzemni, odpadni vody Stanoveni rozpusteneho kysliku metodou LDO (luminiscencne) a % nasyceni vypoctem z namerenych hodnot ZCHR-03 (CSN ISO 17289)","search_en":"Drinking, surface, ground and waste water Determination of dissolved oxygen by the LDO method (luminescence) and % saturation by calculation from measured values ZCHR-03 (ČSN ISO 17289)","search_zh":"饮用水、地表水、地下水、废水 LDO（发光）法测定溶解氧，根据测量值计算饱和度% ZCHR-03 (ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e82cdc5d60813c4a8d8ef81a","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.5","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie kwasowej pojemności neutralizacji (KNK) metodą miareczkową","methodology_en":"Determination of acid neutralizing capacity (ANC) by titration","methodology_zh":"滴定法测定酸中和容量（ANC）","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasowej pojemności neutralizacji (KNK) metodą miareczkową","reference":"ZCHR-04 (ČSN EN ISO 9963-1)","norm_bases":["ZCHR-04","ČSN EN ISO 9963-1"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie kwasowej pojemności neutralizacji (KNK) metodą miareczkową Pitné, povrchové, podzemní, odpadní vody Stanovení kyselinové neutralizační kapacity (KNK) titračně ZCHR-04 (ČSN EN ISO 9963-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie kwasowej pojemnosci neutralizacji (KNK) metoda miareczkowa Pitne, povrchove, podzemni, odpadni vody Stanoveni kyselinove neutralizacni kapacity (KNK) titracne ZCHR-04 (CSN EN ISO 9963-1)","search_en":"Drinking, surface, ground and waste water Determination of acid neutralizing capacity (ANC) by titration ZCHR-04 (ČSN EN ISO 9963-1)","search_zh":"饮用水、地表水、地下水、废水 滴定法测定酸中和容量（ANC） ZCHR-04 (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"98966b9aeec7c98b9316dc52","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.6","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie zawiesiny ogólnej (NL) metodą wagową","methodology_en":"Determination of suspended solids (NL) gravimetrically","methodology_zh":"重量法测定悬浮物（NL）","methodology_cs":"Stanovení nerozpuštěných látek (NL) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny ogólnej (NL) metodą wagową","reference":"ZCHR-24 (ČSN EN 872; ČSN 75 7346)","norm_bases":["ZCHR-24","ČSN EN 872","ČSN 75 7346"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie zawiesiny ogólnej (NL) metodą wagową Pitné, povrchové, podzemní, odpadní vody Stanovení nerozpuštěných látek (NL) gravimetricky ZCHR-24 (ČSN EN 872; ČSN 75 7346) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie zawiesiny ogolnej (NL) metoda wagowa Pitne, povrchove, podzemni, odpadni vody Stanoveni nerozpustenych latek (NL) gravimetricky ZCHR-24 (CSN EN 872; CSN 75 7346)","search_en":"Drinking, surface, ground and waste water Determination of suspended solids (NL) gravimetrically ZCHR-24 (ČSN EN 872; ČSN 75 7346)","search_zh":"饮用水、地表水、地下水、废水 重量法测定悬浮物（NL） ZCHR-24 (ČSN EN 872; ČSN 75 7346)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"acb1cfc0076e0dcebd9b5883","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.7","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny","test_object_en":"Drinking, surface, ground and waste water, aqueous extract","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodný výluh","methodology":"Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","methodology_en":"Determination of dissolved solids (RL) and dissolved inorganic salts (RAS) gravimetrically","methodology_zh":"重量法测定溶解性物质（RL）和溶解性无机盐（RAS）","methodology_cs":"Stanovení rozpuštěných látek (RL) a rozpuštěných anorganických solí (RAS) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","reference":"ZCHR-25 (ČSN 75 7346; ČSN 75 7347)","norm_bases":["ZCHR-25","ČSN 75 7346","ČSN 75 7347"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metodą wagową Pitné, povrchové, podzemní, odpadní vody, vodný výluh Stanovení rozpuštěných látek (RL) a rozpuštěných anorganických solí (RAS) gravimetricky ZCHR-25 (ČSN 75 7346; ČSN 75 7347) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciag wodny Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metoda wagowa Pitne, povrchove, podzemni, odpadni vody, vodny vyluh Stanoveni rozpustenych latek (RL) a rozpustenych anorganickych soli (RAS) gravimetricky ZCHR-25 (CSN 75 7346; CSN 75 7347)","search_en":"Drinking, surface, ground and waste water, aqueous extract Determination of dissolved solids (RL) and dissolved inorganic salts (RAS) gravimetrically ZCHR-25 (ČSN 75 7346; ČSN 75 7347)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 重量法测定溶解性物质（RL）和溶解性无机盐（RAS） ZCHR-25 (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"add24a67e00a5da445db48f0","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.8","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) z oznaczaniem tlenu rozpuszczonego metodą luminescencyjną","methodology_en":"Determination of biochemical oxygen demand after n days (BODn) with luminescent determination of dissolved oxygen","methodology_zh":"发光法测定溶解氧的n日生化需氧量（BODn）测定","methodology_cs":"Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) se stanovením rozpuštěného kyslíku luminiscenčně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) z oznaczaniem tlenu rozpuszczonego metodą luminescencyjną","reference":"ZCHR-10 (ČSN EN ISO 5815-1; ČSN EN 1899-2)","norm_bases":["ZCHR-10","ČSN EN ISO 5815-1","ČSN EN 1899-2"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) z oznaczaniem tlenu rozpuszczonego metodą luminescencyjną Pitné, povrchové, podzemní, odpadní vody Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) se stanovením rozpuštěného kyslíku luminiscenčně ZCHR-10 (ČSN EN ISO 5815-1; ČSN EN 1899-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) z oznaczaniem tlenu rozpuszczonego metoda luminescencyjna Pitne, povrchove, podzemni, odpadni vody Stanoveni biochemicke spotreby kysliku po n dnech (BSKn) se stanovenim rozpusteneho kysliku luminiscencne ZCHR-10 (CSN EN ISO 5815-1; CSN EN 1899-2)","search_en":"Drinking, surface, ground and waste water Determination of biochemical oxygen demand after n days (BODn) with luminescent determination of dissolved oxygen ZCHR-10 (ČSN EN ISO 5815-1; ČSN EN 1899-2)","search_zh":"饮用水、地表水、地下水、废水 发光法测定溶解氧的n日生化需氧量（BODn）测定 ZCHR-10 (ČSN EN ISO 5815-1; ČSN EN 1899-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"16fbbb9074965c666b56a2d5","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.9","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metodą spektrofotometryczną – komercyjny zestaw analityczny HACH","methodology_en":"Determination of chemical oxygen demand with potassium dichromate (CODCr) spectrophotometrically – HACH commercial analytical kit","methodology_zh":"重铬酸钾分光光度法测定化学需氧量（CODCr） – HACH商业分析试剂盒","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) spektrofotometricky – analytická komerční souprava HACH","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metodą spektrofotometryczną – komercyjny zestaw analityczny HACH","reference":"ZCHR-26 (ČSN ISO 15705; návod firmy HACH)","norm_bases":["ZCHR-26","ČSN ISO 15705","návod firmy HACH"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metodą spektrofotometryczną – komercyjny zestaw analityczny HACH Pitné, povrchové, podzemní, odpadní vody Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) spektrofotometricky – analytická komerční souprava HACH ZCHR-26 (ČSN ISO 15705; návod firmy HACH) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metoda spektrofotometryczna – komercyjny zestaw analityczny HACH Pitne, povrchove, podzemni, odpadni vody Stanoveni chemicke spotreby kysliku dichromanem draselnym (CHSKCr) spektrofotometricky – analyticka komercni souprava HACH ZCHR-26 (CSN ISO 15705; navod firmy HACH)","search_en":"Drinking, surface, ground and waste water Determination of chemical oxygen demand with potassium dichromate (CODCr) spectrophotometrically – HACH commercial analytical kit ZCHR-26 (ČSN ISO 15705; návod firmy HACH)","search_zh":"饮用水、地表水、地下水、废水 重铬酸钾分光光度法测定化学需氧量（CODCr） – HACH商业分析试剂盒 ZCHR-26 (ČSN ISO 15705; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c4ff0ea1bff05034a5d12cd","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.10","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne","test_object_en":"Drinking, surface and ground water","test_object_zh":"饮用水、地表水、地下水","test_object_cs":"Pitné, povrchové, podzemní vody","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZTMn) metodą miareczkową","methodology_en":"Determination of chemical oxygen demand with potassium permanganate (CODMn) by titration","methodology_zh":"高锰酸钾滴定法测定化学需氧量（CODMn）","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem draselným (CHSKMn) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZTMn) metodą miareczkową","reference":"ZCHR-12 (ČSN EN ISO 8467)","norm_bases":["ZCHR-12","ČSN EN ISO 8467"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZTMn) metodą miareczkową Pitné, povrchové, podzemní vody Stanovení chemické spotřeby kyslíku manganistanem draselným (CHSKMn) titračně ZCHR-12 (ČSN EN ISO 8467) Wody przeznaczone do spozycia, powierzchniowe, podziemne Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZTMn) metoda miareczkowa Pitne, povrchove, podzemni vody Stanoveni chemicke spotreby kysliku manganistanem draselnym (CHSKMn) titracne ZCHR-12 (CSN EN ISO 8467)","search_en":"Drinking, surface and ground water Determination of chemical oxygen demand with potassium permanganate (CODMn) by titration ZCHR-12 (ČSN EN ISO 8467)","search_zh":"饮用水、地表水、地下水 高锰酸钾滴定法测定化学需氧量（CODMn） ZCHR-12 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7598134a23fce28f40094dc8","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.11","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny","test_object_en":"Drinking, surface, ground and waste water, aqueous extract","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodný výluh","methodology":"Oznaczanie węgla całkowitego (TC) i węgla nieorganicznego (TIC) spektrofotometrycznie analizatorem TOC oraz ogólnego i rozpuszczonego węgla organicznego (TOC, DOC) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of total carbon (TC) and total inorganic carbon (TIC) spectrophotometrically with a TOC analyser and total organic and dissolved organic carbon (TOC, DOC) by calculation from measured values","methodology_zh":"TOC分析仪分光光度法测定总碳（TC）和总无机碳（TIC），根据测量值计算总有机碳和溶解性有机碳（TOC、DOC）","methodology_cs":"Stanovení celkového uhlíku (TC) a celkového anorganického uhlíku (TIC) spektrofotometricky analyzátorem TOC a celkového organického a rozpuštěného organického uhlíku (TOC, DOC) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węgla całkowitego (TC) i węgla nieorganicznego (TIC) spektrofotometrycznie analizatorem TOC oraz ogólnego i rozpuszczonego węgla organicznego (TOC, DOC) obliczeniowo z wartości zmierzonych","reference":"ZCHR-14 (ČSN EN 1484; ČSN EN ISO 20236)","norm_bases":["ZCHR-14","ČSN EN 1484","ČSN EN ISO 20236"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny Oznaczanie węgla całkowitego (TC) i węgla nieorganicznego (TIC) spektrofotometrycznie analizatorem TOC oraz ogólnego i rozpuszczonego węgla organicznego (TOC, DOC) obliczeniowo z wartości zmierzonych Pitné, povrchové, podzemní, odpadní vody, vodný výluh Stanovení celkového uhlíku (TC) a celkového anorganického uhlíku (TIC) spektrofotometricky analyzátorem TOC a celkového organického a rozpuštěného organického uhlíku (TOC, DOC) výpočtem z naměřených hodnot ZCHR-14 (ČSN EN 1484; ČSN EN ISO 20236) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciag wodny Oznaczanie wegla calkowitego (TC) i wegla nieorganicznego (TIC) spektrofotometrycznie analizatorem TOC oraz ogolnego i rozpuszczonego wegla organicznego (TOC, DOC) obliczeniowo z wartosci zmierzonych Pitne, povrchove, podzemni, odpadni vody, vodny vyluh Stanoveni celkoveho uhliku (TC) a celkoveho anorganickeho uhliku (TIC) spektrofotometricky analyzatorem TOC a celkoveho organickeho a rozpusteneho organickeho uhliku (TOC, DOC) vypoctem z namerenych hodnot ZCHR-14 (CSN EN 1484; CSN EN ISO 20236)","search_en":"Drinking, surface, ground and waste water, aqueous extract Determination of total carbon (TC) and total inorganic carbon (TIC) spectrophotometrically with a TOC analyser and total organic and dissolved organic carbon (TOC, DOC) by calculation from measured values ZCHR-14 (ČSN EN 1484; ČSN EN ISO 20236)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 TOC分析仪分光光度法测定总碳（TC）和总无机碳（TIC），根据测量值计算总有机碳和溶解性有机碳（TOC、DOC） ZCHR-14 (ČSN EN 1484; ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"180e35d13418b57743260ba0","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.12","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny","test_object_en":"Drinking, surface, ground and waste water, aqueous extract","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodný výluh","methodology":"Oznaczanie jonów amonowych metodą spektrofotometryczną i azotu amonowego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ammonium ions spectrophotometrically and ammonium nitrogen by calculation from measured values","methodology_zh":"分光光度法测定铵离子，根据测量值计算氨氮","methodology_cs":"Stanovení amonných iontů spektrofotometricky a amoniakálního dusíku výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą spektrofotometryczną i azotu amonowego obliczeniowo z wartości zmierzonych","reference":"ZCHR-16 (ČSN ISO 7150-1)","norm_bases":["ZCHR-16","ČSN ISO 7150-1"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny Oznaczanie jonów amonowych metodą spektrofotometryczną i azotu amonowego obliczeniowo z wartości zmierzonych Pitné, povrchové, podzemní, odpadní vody, vodný výluh Stanovení amonných iontů spektrofotometricky a amoniakálního dusíku výpočtem z naměřených hodnot ZCHR-16 (ČSN ISO 7150-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciag wodny Oznaczanie jonow amonowych metoda spektrofotometryczna i azotu amonowego obliczeniowo z wartosci zmierzonych Pitne, povrchove, podzemni, odpadni vody, vodny vyluh Stanoveni amonnych iontu spektrofotometricky a amoniakalniho dusiku vypoctem z namerenych hodnot ZCHR-16 (CSN ISO 7150-1)","search_en":"Drinking, surface, ground and waste water, aqueous extract Determination of ammonium ions spectrophotometrically and ammonium nitrogen by calculation from measured values ZCHR-16 (ČSN ISO 7150-1)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 分光光度法测定铵离子，根据测量值计算氨氮 ZCHR-16 (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e8f3d2454899d8993dd35355","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.13","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie azotynów metodą spektrofotometryczną i azotu azotynowego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of nitrites spectrophotometrically and nitrite nitrogen by calculation from measured values","methodology_zh":"分光光度法测定亚硝酸盐，根据测量值计算亚硝酸盐氮","methodology_cs":"Stanovení dusitanů spektrofotometricky a dusitanového dusíku výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów metodą spektrofotometryczną i azotu azotynowego obliczeniowo z wartości zmierzonych","reference":"ZCHR-28 (ČSN EN 26 777)","norm_bases":["ZCHR-28","ČSN EN 26 777"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie azotynów metodą spektrofotometryczną i azotu azotynowego obliczeniowo z wartości zmierzonych Pitné, povrchové, podzemní, odpadní vody Stanovení dusitanů spektrofotometricky a dusitanového dusíku výpočtem z naměřených hodnot ZCHR-28 (ČSN EN 26 777) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie azotynow metoda spektrofotometryczna i azotu azotynowego obliczeniowo z wartosci zmierzonych Pitne, povrchove, podzemni, odpadni vody Stanoveni dusitanu spektrofotometricky a dusitanoveho dusiku vypoctem z namerenych hodnot ZCHR-28 (CSN EN 26 777)","search_en":"Drinking, surface, ground and waste water Determination of nitrites spectrophotometrically and nitrite nitrogen by calculation from measured values ZCHR-28 (ČSN EN 26 777)","search_zh":"饮用水、地表水、地下水、废水 分光光度法测定亚硝酸盐，根据测量值计算亚硝酸盐氮 ZCHR-28 (ČSN EN 26 777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dee7973cafa3153af35f78e8","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.14","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie ortofosforanów i fosforanów hydrolizujących metodą spektrofotometryczną po reakcji z molibdenianem amonu oraz fosforu fosforanowego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of orthophosphates and hydrolysable phosphates spectrophotometrically after reaction with ammonium molybdate and phosphate phosphorus by calculation from measured values","methodology_zh":"钼酸铵反应后分光光度法测定正磷酸盐和可水解磷酸盐，根据测量值计算磷酸盐磷","methodology_cs":"Stanovení orthofosforečnanů a hydrolyzovatelných fosforečnanů spektrofotometricky po reakci s molybdenanem amonným a fosforečnanového fosforu výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ortofosforanów i fosforanów hydrolizujących metodą spektrofotometryczną po reakcji z molibdenianem amonu oraz fosforu fosforanowego obliczeniowo z wartości zmierzonych","reference":"ZCHR-34 (ČSN EN ISO 6878)","norm_bases":["ZCHR-34","ČSN EN ISO 6878"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie ortofosforanów i fosforanów hydrolizujących metodą spektrofotometryczną po reakcji z molibdenianem amonu oraz fosforu fosforanowego obliczeniowo z wartości zmierzonych Pitné, povrchové, podzemní, odpadní vody Stanovení orthofosforečnanů a hydrolyzovatelných fosforečnanů spektrofotometricky po reakci s molybdenanem amonným a fosforečnanového fosforu výpočtem z naměřených hodnot ZCHR-34 (ČSN EN ISO 6878) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie ortofosforanow i fosforanow hydrolizujacych metoda spektrofotometryczna po reakcji z molibdenianem amonu oraz fosforu fosforanowego obliczeniowo z wartosci zmierzonych Pitne, povrchove, podzemni, odpadni vody Stanoveni orthofosforecnanu a hydrolyzovatelnych fosforecnanu spektrofotometricky po reakci s molybdenanem amonnym a fosforecnanoveho fosforu vypoctem z namerenych hodnot ZCHR-34 (CSN EN ISO 6878)","search_en":"Drinking, surface, ground and waste water Determination of orthophosphates and hydrolysable phosphates spectrophotometrically after reaction with ammonium molybdate and phosphate phosphorus by calculation from measured values ZCHR-34 (ČSN EN ISO 6878)","search_zh":"饮用水、地表水、地下水、废水 钼酸铵反应后分光光度法测定正磷酸盐和可水解磷酸盐，根据测量值计算磷酸盐磷 ZCHR-34 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e434a098d4ad7bffb68c7fb4","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.15","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie fosforu ogólnego metodą spektrofotometryczną po utlenieniu nadtlenodisiarczanem","methodology_en":"Determination of total phosphorus spectrophotometrically after peroxodisulphate oxidation","methodology_zh":"过硫酸盐氧化后分光光度法测定总磷","methodology_cs":"Stanovení celkového fosforu spektrofotometricky po oxidaci peroxodisíranem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu ogólnego metodą spektrofotometryczną po utlenieniu nadtlenodisiarczanem","reference":"ZCHR-31 (ČSN EN ISO 6878)","norm_bases":["ZCHR-31","ČSN EN ISO 6878"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie fosforu ogólnego metodą spektrofotometryczną po utlenieniu nadtlenodisiarczanem Pitné, povrchové, podzemní, odpadní vody Stanovení celkového fosforu spektrofotometricky po oxidaci peroxodisíranem ZCHR-31 (ČSN EN ISO 6878) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie fosforu ogolnego metoda spektrofotometryczna po utlenieniu nadtlenodisiarczanem Pitne, povrchove, podzemni, odpadni vody Stanoveni celkoveho fosforu spektrofotometricky po oxidaci peroxodisiranem ZCHR-31 (CSN EN ISO 6878)","search_en":"Drinking, surface, ground and waste water Determination of total phosphorus spectrophotometrically after peroxodisulphate oxidation ZCHR-31 (ČSN EN ISO 6878)","search_zh":"饮用水、地表水、地下水、废水 过硫酸盐氧化后分光光度法测定总磷 ZCHR-31 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ab0c27896172fe73974c97ab","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.16","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny","test_object_en":"Drinking, surface, ground and waste water, aqueous extract","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodný výluh","methodology":"Oznaczanie jonów rozpuszczonych metodą kapilarnej elektroforezy strefowej oraz azotu azotynowego i azotanowego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of dissolved ions by capillary zone electrophoresis and nitrite and nitrate nitrogen by calculation from measured values","methodology_zh":"毛细管区带电泳法测定溶解离子，根据测量值计算亚硝酸盐氮和硝酸盐氮","methodology_cs":"Stanovení rozpuštěných iontů metodou kapilární zónové elektroforézy a stanovení dusitanového a dusičnanového dusíku výpočtem z naměřených hodnot","parameters":[{"name":"Chlorki","range":""},{"name":"Siarczany","range":""},{"name":"Azotany","range":""},{"name":"Azotyny","range":""}],"parameters_en":[{"name":"Chlorides","range":""},{"name":"Sulphates","range":""},{"name":"Nitrates","range":""},{"name":"Nitrites","range":""}],"parameters_zh":[{"name":"氯化物","range":""},{"name":"硫酸盐","range":""},{"name":"硝酸盐","range":""},{"name":"亚硝酸盐","range":""}],"parameters_cs":[{"name":"Chloridy","range":""},{"name":"sírany","range":""},{"name":"dusičnany","range":""},{"name":"dusitany","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów rozpuszczonych metodą kapilarnej elektroforezy strefowej oraz azotu azotynowego i azotanowego obliczeniowo z wartości zmierzonych\nZakres:\nChlorki\nSiarczany\nAzotany\nAzotyny","reference":"ZCHR-32 (US EPA 6500)","norm_bases":["ZCHR-32","US EPA 6500"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny Oznaczanie jonów rozpuszczonych metodą kapilarnej elektroforezy strefowej oraz azotu azotynowego i azotanowego obliczeniowo z wartości zmierzonych Chlorki  Siarczany  Azotany  Azotyny  Pitné, povrchové, podzemní, odpadní vody, vodný výluh Stanovení rozpuštěných iontů metodou kapilární zónové elektroforézy a stanovení dusitanového a dusičnanového dusíku výpočtem z naměřených hodnot Chloridy  sírany  dusičnany  dusitany  ZCHR-32 (US EPA 6500) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciag wodny Oznaczanie jonow rozpuszczonych metoda kapilarnej elektroforezy strefowej oraz azotu azotynowego i azotanowego obliczeniowo z wartosci zmierzonych Chlorki  Siarczany  Azotany  Azotyny  Pitne, povrchove, podzemni, odpadni vody, vodny vyluh Stanoveni rozpustenych iontu metodou kapilarni zonove elektroforezy a stanoveni dusitanoveho a dusicnanoveho dusiku vypoctem z namerenych hodnot Chloridy  sirany  dusicnany  dusitany  ZCHR-32 (US EPA 6500)","search_en":"Drinking, surface, ground and waste water, aqueous extract Determination of dissolved ions by capillary zone electrophoresis and nitrite and nitrate nitrogen by calculation from measured values Chlorides  Sulphates  Nitrates  Nitrites  ZCHR-32 (US EPA 6500)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 毛细管区带电泳法测定溶解离子，根据测量值计算亚硝酸盐氮和硝酸盐氮 氯化物  硫酸盐  硝酸盐  亚硝酸盐  ZCHR-32 (US EPA 6500)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75804a26576a96ace2790bb1","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.17","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny","test_object_en":"Drinking, surface, ground and waste water, aqueous extract","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodný výluh","methodology":"Oznaczanie azotu ogólnego metodą chemiluminescencyjną","methodology_en":"Determination of total nitrogen by chemiluminescence","methodology_zh":"化学发光法测定总氮","methodology_cs":"Stanovení celkového dusíku chemiluminiscenčně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego metodą chemiluminescencyjną","reference":"ZCHR-36 (ČSN EN ISO 20236)","norm_bases":["ZCHR-36","ČSN EN ISO 20236"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciąg wodny Oznaczanie azotu ogólnego metodą chemiluminescencyjną Pitné, povrchové, podzemní, odpadní vody, vodný výluh Stanovení celkového dusíku chemiluminiscenčně ZCHR-36 (ČSN EN ISO 20236) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciag wodny Oznaczanie azotu ogolnego metoda chemiluminescencyjna Pitne, povrchove, podzemni, odpadni vody, vodny vyluh Stanoveni celkoveho dusiku chemiluminiscencne ZCHR-36 (CSN EN ISO 20236)","search_en":"Drinking, surface, ground and waste water, aqueous extract Determination of total nitrogen by chemiluminescence ZCHR-36 (ČSN EN ISO 20236)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 化学发光法测定总氮 ZCHR-36 (ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"599350f72aa9ad378b90692a","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.18","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity nephelometrically","methodology_zh":"散射法测定浊度","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną","reference":"ZCHR-05 (ČSN EN ISO 7027-1)","norm_bases":["ZCHR-05","ČSN EN ISO 7027-1"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie mętności metodą nefelometryczną Pitné, povrchové, podzemní, odpadní vody Stanovení zákalu nefelometricky ZCHR-05 (ČSN EN ISO 7027-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie metnosci metoda nefelometryczna Pitne, povrchove, podzemni, odpadni vody Stanoveni zakalu nefelometricky ZCHR-05 (CSN EN ISO 7027-1)","search_en":"Drinking, surface, ground and waste water Determination of turbidity nephelometrically ZCHR-05 (ČSN EN ISO 7027-1)","search_zh":"饮用水、地表水、地下水、废水 散射法测定浊度 ZCHR-05 (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0fa905727b88d2c96b4edf91","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.19","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciągi wodne","test_object_en":"Drinking, surface, ground and waste water, aqueous extracts","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodné výluhy","methodology":"Oznaczanie pierwiastków metodą płomieniowej absorpcyjnej spektrometrii atomowej oraz sumy wapnia i magnezu obliczeniowo z wartości zmierzonych","methodology_en":"Determination of elements by flame atomic absorption spectrometry and the sum of calcium and magnesium by calculation from measured values","methodology_zh":"火焰原子吸收光谱法测定元素，根据测量值计算钙镁总量","methodology_cs":"Stanovení prvků metodou atomové absorpční spektrometrie v plameni a stanovení sumy vápníku a hořčíku výpočtem z naměřených hodnot","parameters":[{"name":"Żelazo (Fe)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Sód (Na)","range":""},{"name":"Potas (K)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Miedź (Cu)","range":""}],"parameters_en":[{"name":"Iron (Fe)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Potassium (K)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Copper (Cu)","range":""}],"parameters_zh":[{"name":"铁（Fe）","range":""},{"name":"锰（Mn）","range":""},{"name":"锌（Zn）","range":""},{"name":"钠（Na）","range":""},{"name":"钾（K）","range":""},{"name":"钙（Ca）","range":""},{"name":"镁（Mg）","range":""},{"name":"铜（Cu）","range":""}],"parameters_cs":[{"name":"Fe","range":""},{"name":"Mn","range":""},{"name":"Zn","range":""},{"name":"Na","range":""},{"name":"K","range":""},{"name":"Ca","range":""},{"name":"Mg","range":""},{"name":"Cu","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą płomieniowej absorpcyjnej spektrometrii atomowej oraz sumy wapnia i magnezu obliczeniowo z wartości zmierzonych\nZakres:\nŻelazo (Fe)\nMangan (Mn)\nCynk (Zn)\nSód (Na)\nPotas (K)\nWapń (Ca)\nMagnez (Mg)\nMiedź (Cu)","reference":"SAA-01 (ČSN ISO 8288; ČSN ISO 9964-1; ČSN ISO 9964-3; ČSN ISO 7980; ČSN 75 7385)","norm_bases":["SAA-01","ČSN ISO 8288","ČSN ISO 9964-1","ČSN ISO 9964-3","ČSN ISO 7980","ČSN 75 7385"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciągi wodne Oznaczanie pierwiastków metodą płomieniowej absorpcyjnej spektrometrii atomowej oraz sumy wapnia i magnezu obliczeniowo z wartości zmierzonych Żelazo (Fe)  Mangan (Mn)  Cynk (Zn)  Sód (Na)  Potas (K)  Wapń (Ca)  Magnez (Mg)  Miedź (Cu)  Pitné, povrchové, podzemní, odpadní vody, vodné výluhy Stanovení prvků metodou atomové absorpční spektrometrie v plameni a stanovení sumy vápníku a hořčíku výpočtem z naměřených hodnot Fe  Mn  Zn  Na  K  Ca  Mg  Cu  SAA-01 (ČSN ISO 8288; ČSN ISO 9964-1; ČSN ISO 9964-3; ČSN ISO 7980; ČSN 75 7385) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciagi wodne Oznaczanie pierwiastkow metoda plomieniowej absorpcyjnej spektrometrii atomowej oraz sumy wapnia i magnezu obliczeniowo z wartosci zmierzonych Zelazo (Fe)  Mangan (Mn)  Cynk (Zn)  Sod (Na)  Potas (K)  Wapn (Ca)  Magnez (Mg)  Miedz (Cu)  Pitne, povrchove, podzemni, odpadni vody, vodne vyluhy Stanoveni prvku metodou atomove absorpcni spektrometrie v plameni a stanoveni sumy vapniku a horciku vypoctem z namerenych hodnot Fe  Mn  Zn  Na  K  Ca  Mg  Cu  SAA-01 (CSN ISO 8288; CSN ISO 9964-1; CSN ISO 9964-3; CSN ISO 7980; CSN 75 7385)","search_en":"Drinking, surface, ground and waste water, aqueous extracts Determination of elements by flame atomic absorption spectrometry and the sum of calcium and magnesium by calculation from measured values Iron (Fe)  Manganese (Mn)  Zinc (Zn)  Sodium (Na)  Potassium (K)  Calcium (Ca)  Magnesium (Mg)  Copper (Cu)  SAA-01 (ČSN ISO 8288; ČSN ISO 9964-1; ČSN ISO 9964-3; ČSN ISO 7980; ČSN 75 7385)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 火焰原子吸收光谱法测定元素，根据测量值计算钙镁总量 铁（Fe）  锰（Mn）  锌（Zn）  钠（Na）  钾（K）  钙（Ca）  镁（Mg）  铜（Cu）  SAA-01 (ČSN ISO 8288; ČSN ISO 9964-1; ČSN ISO 9964-3; ČSN ISO 7980; ČSN 75 7385)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca046490b8a048f61876574c","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.20","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciągi wodne","test_object_en":"Drinking, surface, ground and waste water, aqueous extracts","test_object_zh":"饮用水、地表水、地下水、废水、水浸出液","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, vodné výluhy","methodology":"Oznaczanie rtęci metodą absorpcyjnej spektrometrii atomowej par rtęci analizatorem AMA","methodology_en":"Determination of mercury by mercury vapour atomic absorption spectrometry with AMA analyser","methodology_zh":"AMA测汞仪汞蒸气原子吸收光谱法测定汞","methodology_cs":"Stanovení rtuti metodou atomové absorpční spektrometrie rtuťových par analyzátorem AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci metodą absorpcyjnej spektrometrii atomowej par rtęci analizatorem AMA","reference":"SAA-12 A (ČSN 75 7440)","norm_bases":["SAA-12 A","ČSN 75 7440"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wyciągi wodne Oznaczanie rtęci metodą absorpcyjnej spektrometrii atomowej par rtęci analizatorem AMA Pitné, povrchové, podzemní, odpadní vody, vodné výluhy Stanovení rtuti metodou atomové absorpční spektrometrie rtuťových par analyzátorem AMA SAA-12 A (ČSN 75 7440) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wyciagi wodne Oznaczanie rteci metoda absorpcyjnej spektrometrii atomowej par rteci analizatorem AMA Pitne, povrchove, podzemni, odpadni vody, vodne vyluhy Stanoveni rtuti metodou atomove absorpcni spektrometrie rtutovych par analyzatorem AMA SAA-12 A (CSN 75 7440)","search_en":"Drinking, surface, ground and waste water, aqueous extracts Determination of mercury by mercury vapour atomic absorption spectrometry with AMA analyser SAA-12 A (ČSN 75 7440)","search_zh":"饮用水、地表水、地下水、废水、水浸出液 AMA测汞仪汞蒸气原子吸收光谱法测定汞 SAA-12 A (ČSN 75 7440)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f6a6092f79653bc4ecd0bb80","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.21","test_object":"Osady denne, zawiesiny rzeczne, osady (szlamy), grunty, biomasa","test_object_en":"Sediments, suspended sediments, sludge, soils, biomass","test_object_zh":"沉积物、悬移质、污泥、土壤、生物质","test_object_cs":"Sedimenty, plaveniny, kaly, zeminy, biomasa","methodology":"Oznaczanie rtęci metodą absorpcyjnej spektrometrii atomowej par rtęci analizatorem AMA","methodology_en":"Determination of mercury by mercury vapour atomic absorption spectrometry with AMA analyser","methodology_zh":"AMA测汞仪汞蒸气原子吸收光谱法测定汞","methodology_cs":"Stanovení rtuti metodou atomové absorpční spektrometrie rtuťových par analyzátorem AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci metodą absorpcyjnej spektrometrii atomowej par rtęci analizatorem AMA","reference":"SAA-12 B (ČSN 75 7440)","norm_bases":["SAA-12 B","ČSN 75 7440"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady denne, zawiesiny rzeczne, osady (szlamy), grunty, biomasa Oznaczanie rtęci metodą absorpcyjnej spektrometrii atomowej par rtęci analizatorem AMA Sedimenty, plaveniny, kaly, zeminy, biomasa Stanovení rtuti metodou atomové absorpční spektrometrie rtuťových par analyzátorem AMA SAA-12 B (ČSN 75 7440) Osady denne, zawiesiny rzeczne, osady (szlamy), grunty, biomasa Oznaczanie rteci metoda absorpcyjnej spektrometrii atomowej par rteci analizatorem AMA Sedimenty, plaveniny, kaly, zeminy, biomasa Stanoveni rtuti metodou atomove absorpcni spektrometrie rtutovych par analyzatorem AMA SAA-12 B (CSN 75 7440)","search_en":"Sediments, suspended sediments, sludge, soils, biomass Determination of mercury by mercury vapour atomic absorption spectrometry with AMA analyser SAA-12 B (ČSN 75 7440)","search_zh":"沉积物、悬移质、污泥、土壤、生物质 AMA测汞仪汞蒸气原子吸收光谱法测定汞 SAA-12 B (ČSN 75 7440)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2482efb374b0bd3a5010fef3","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.22","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, ekstrakt do n-heptanu","test_object_en":"Drinking, surface, ground and waste water, n-heptane extract","test_object_zh":"饮用水、地表水、地下水、废水、正庚烷提取物","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody, extrakt do n-heptanu","methodology":"Oznaczanie węglowodorów C10-C40 metodą GC/FID","methodology_en":"Determination of hydrocarbons C10-C40 by GC/FID","methodology_zh":"GC/FID法测定C10-C40烃","methodology_cs":"Stanovení uhlovodíků C10-C40 metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10-C40 metodą GC/FID","reference":"SOA-11 (ČSN EN ISO 9377-2)","norm_bases":["SOA-11","ČSN EN ISO 9377-2"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, ekstrakt do n-heptanu Oznaczanie węglowodorów C10-C40 metodą GC/FID Pitné, povrchové, podzemní, odpadní vody, extrakt do n-heptanu Stanovení uhlovodíků C10-C40 metodou GC/FID SOA-11 (ČSN EN ISO 9377-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, ekstrakt do n-heptanu Oznaczanie weglowodorow C10-C40 metoda GC/FID Pitne, povrchove, podzemni, odpadni vody, extrakt do n-heptanu Stanoveni uhlovodiku C10-C40 metodou GC/FID SOA-11 (CSN EN ISO 9377-2)","search_en":"Drinking, surface, ground and waste water, n-heptane extract Determination of hydrocarbons C10-C40 by GC/FID SOA-11 (ČSN EN ISO 9377-2)","search_zh":"饮用水、地表水、地下水、废水、正庚烷提取物 GC/FID法测定C10-C40烃 SOA-11 (ČSN EN ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4d18d9f32605477f3b5548da","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.23","test_object":"Osady denne, osady (szlamy), grunty, biomasa","test_object_en":"Sediments, sludge, soils, biomass","test_object_zh":"沉积物、污泥、土壤、生物质","test_object_cs":"Sedimenty, kaly, zeminy, biomasa","methodology":"Oznaczanie suchej masy i strat prażenia metodą wagową","methodology_en":"Determination of dry matter and loss on ignition gravimetrically","methodology_zh":"重量法测定干物质和灼烧减量","methodology_cs":"Stanovení sušiny a ztráty žíháním gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy i strat prażenia metodą wagową","reference":"ZCHR-06 (ČSN EN 12880; ČSN ISO 11465; ČSN EN 15934; ČSN EN 15935)","norm_bases":["ZCHR-06","ČSN EN 12880","ČSN ISO 11465","ČSN EN 15934","ČSN EN 15935"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady denne, osady (szlamy), grunty, biomasa Oznaczanie suchej masy i strat prażenia metodą wagową Sedimenty, kaly, zeminy, biomasa Stanovení sušiny a ztráty žíháním gravimetricky ZCHR-06 (ČSN EN 12880; ČSN ISO 11465; ČSN EN 15934; ČSN EN 15935) Osady denne, osady (szlamy), grunty, biomasa Oznaczanie suchej masy i strat prazenia metoda wagowa Sedimenty, kaly, zeminy, biomasa Stanoveni susiny a ztraty zihanim gravimetricky ZCHR-06 (CSN EN 12880; CSN ISO 11465; CSN EN 15934; CSN EN 15935)","search_en":"Sediments, sludge, soils, biomass Determination of dry matter and loss on ignition gravimetrically ZCHR-06 (ČSN EN 12880; ČSN ISO 11465; ČSN EN 15934; ČSN EN 15935)","search_zh":"沉积物、污泥、土壤、生物质 重量法测定干物质和灼烧减量 ZCHR-06 (ČSN EN 12880; ČSN ISO 11465; ČSN EN 15934; ČSN EN 15935)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ee06ed94ca9cf6d3df07bb29","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.24","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie pierwiastków metodą ICP-MS i wybranych parametrów obliczeniowo z wartości zmierzonych","methodology_en":"Determination of elements by ICP-MS and selected parameters by calculation from measured values","methodology_zh":"ICP-MS法测定元素，根据测量值计算部分参数","methodology_cs":"Stanovení prvků metodou ICP-MS a vybraných parametrů výpočtem z naměřených hodnot","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Lit (Li)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Tytan (Ti)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Lithium (Li)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Titanium (Ti)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"锂（Li）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"锶（Sr）","range":""},{"name":"钛（Ti）","range":""},{"name":"铊（Tl）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Li","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Sr","range":""},{"name":"Ti","range":""},{"name":"Tl","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["Twardość (z obliczeń)"],"computed_en":["Hardness (by calculation)"],"computed_zh":["硬度（计算）"],"computed_cs":["dopočtem: tvrdost"],"activity":"Oznaczanie pierwiastków metodą ICP-MS i wybranych parametrów obliczeniowo z wartości zmierzonych\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nLit (Li)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nStront (Sr)\nTytan (Ti)\nTal (Tl)\nWanad (V)\nCynk (Zn)","reference":"SAA-03 A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A)","norm_bases":["SAA-03 A","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2","US EPA 6020A"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie pierwiastków metodą ICP-MS i wybranych parametrów obliczeniowo z wartości zmierzonych Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Stront (Sr)  Tytan (Ti)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Twardość (z obliczeń) Pitné, povrchové, podzemní, odpadní vody Stanovení prvků metodou ICP-MS a vybraných parametrů výpočtem z naměřených hodnot Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Sr  Ti  Tl  V  Zn  dopočtem: tvrdost SAA-03 A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie pierwiastkow metoda ICP-MS i wybranych parametrow obliczeniowo z wartosci zmierzonych Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Stront (Sr)  Tytan (Ti)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Twardosc (z obliczen) Pitne, povrchove, podzemni, odpadni vody Stanoveni prvku metodou ICP-MS a vybranych parametru vypoctem z namerenych hodnot Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Sr  Ti  Tl  V  Zn  dopoctem: tvrdost SAA-03 A (CSN EN ISO 17294-1; CSN EN ISO 17294-2; US EPA 6020A)","search_en":"Drinking, surface, ground and waste water Determination of elements by ICP-MS and selected parameters by calculation from measured values Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Lithium (Li)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Strontium (Sr)  Titanium (Ti)  Thallium (Tl)  Vanadium (V)  Zinc (Zn)  Hardness (by calculation) SAA-03 A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A)","search_zh":"饮用水、地表水、地下水、废水 ICP-MS法测定元素，根据测量值计算部分参数 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  锂（Li）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  锶（Sr）  钛（Ti）  铊（Tl）  钒（V）  锌（Zn）  硬度（计算） SAA-03 A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f87a93fbdd54b92b86e5ce4f","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1.25","test_object":"Osady denne, zawiesiny rzeczne, osady (szlamy), grunty, biomasa","test_object_en":"Sediments, suspended sediments, sludge, soils, biomass","test_object_zh":"沉积物、悬移质、污泥、土壤、生物质","test_object_cs":"Sedimenty, plaveniny, kaly, zeminy, biomasa","methodology":"Oznaczanie pierwiastków metodą ICP-MS","methodology_en":"Determination of elements by ICP-MS","methodology_zh":"ICP-MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP-MS","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Lit (Li)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Tytan (Ti)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Lithium (Li)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Titanium (Ti)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"锂（Li）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"锶（Sr）","range":""},{"name":"钛（Ti）","range":""},{"name":"铊（Tl）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Li","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Sr","range":""},{"name":"Ti","range":""},{"name":"Tl","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP-MS\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nLit (Li)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nStront (Sr)\nTytan (Ti)\nTal (Tl)\nWanad (V)\nCynk (Zn)","reference":"SAA-03 B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A)","norm_bases":["SAA-03 B","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2","US EPA 6020A"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrochemiczne","regulatory_area_en":"Hydrochemical tests","regulatory_area_zh":"水化学检测","regulatory_area_cs":"Hydrochemické zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady denne, zawiesiny rzeczne, osady (szlamy), grunty, biomasa Oznaczanie pierwiastków metodą ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Stront (Sr)  Tytan (Ti)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Sedimenty, plaveniny, kaly, zeminy, biomasa Stanovení prvků metodou ICP-MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Sr  Ti  Tl  V  Zn  SAA-03 B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A) Osady denne, zawiesiny rzeczne, osady (szlamy), grunty, biomasa Oznaczanie pierwiastkow metoda ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Stront (Sr)  Tytan (Ti)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Sedimenty, plaveniny, kaly, zeminy, biomasa Stanoveni prvku metodou ICP-MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Sr  Ti  Tl  V  Zn  SAA-03 B (CSN EN ISO 17294-1; CSN EN ISO 17294-2; US EPA 6020A)","search_en":"Sediments, suspended sediments, sludge, soils, biomass Determination of elements by ICP-MS Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Lithium (Li)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Strontium (Sr)  Titanium (Ti)  Thallium (Tl)  Vanadium (V)  Zinc (Zn)  SAA-03 B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A)","search_zh":"沉积物、悬移质、污泥、土壤、生物质 ICP-MS法测定元素 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  锂（Li）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  锶（Sr）  钛（Ti）  铊（Tl）  钒（V）  锌（Zn）  SAA-03 B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; US EPA 6020A)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9521f37b3bb16a168b95522c","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"2.1","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą hodowlaną","methodology_en":"Determination of thermotolerant coliform bacteria and Escherichia coli by cultivation","methodology_zh":"培养法测定耐热大肠菌群和大肠埃希氏菌","methodology_cs":"Stanovení termotolerantních koliformních bakterií a Escherichia coli kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą hodowlaną","reference":"MBI-16 (ČSN 75 7835)","norm_bases":["MBI-16","ČSN 75 7835"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania mikrobiologiczne","regulatory_area_en":"Microbiological tests","regulatory_area_zh":"微生物检测","regulatory_area_cs":"Mikrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą hodowlaną Pitné, povrchové, podzemní, odpadní vody Stanovení termotolerantních koliformních bakterií a Escherichia coli kultivačně MBI-16 (ČSN 75 7835) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metoda hodowlana Pitne, povrchove, podzemni, odpadni vody Stanoveni termotolerantnich koliformnich bakterii a Escherichia coli kultivacne MBI-16 (CSN 75 7835)","search_en":"Drinking, surface, ground and waste water Determination of thermotolerant coliform bacteria and Escherichia coli by cultivation MBI-16 (ČSN 75 7835)","search_zh":"饮用水、地表水、地下水、废水 培养法测定耐热大肠菌群和大肠埃希氏菌 MBI-16 (ČSN 75 7835)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2aef33c70a9f912088e45bb9","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"2.2","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface and waste water","test_object_zh":"地表水、废水","test_object_cs":"Povrchové, odpadní vody","methodology":"Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą hodowlaną","methodology_en":"Determination of coliform bacteria in non-disinfected water by cultivation","methodology_zh":"培养法测定未消毒水中的大肠菌群","methodology_cs":"Stanovení koliformních bakterií v nedezinfikovaných vodách kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą hodowlaną","reference":"MBI-03 (ČSN 75 7837)","norm_bases":["MBI-03","ČSN 75 7837"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania mikrobiologiczne","regulatory_area_en":"Microbiological tests","regulatory_area_zh":"微生物检测","regulatory_area_cs":"Mikrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą hodowlaną Povrchové, odpadní vody Stanovení koliformních bakterií v nedezinfikovaných vodách kultivačně MBI-03 (ČSN 75 7837) Wody powierzchniowe, scieki Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metoda hodowlana Povrchove, odpadni vody Stanoveni koliformnich bakterii v nedezinfikovanych vodach kultivacne MBI-03 (CSN 75 7837)","search_en":"Surface and waste water Determination of coliform bacteria in non-disinfected water by cultivation MBI-03 (ČSN 75 7837)","search_zh":"地表水、废水 培养法测定未消毒水中的大肠菌群 MBI-03 (ČSN 75 7837)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e65c8d49c8584876abd9dcf2","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"2.3","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie enterokoków metodą hodowlaną","methodology_en":"Determination of enterococci by cultivation","methodology_zh":"培养法测定肠球菌","methodology_cs":"Stanovení enterokoků kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków metodą hodowlaną","reference":"MBI-05 (ČSN EN ISO 7899-2)","norm_bases":["MBI-05","ČSN EN ISO 7899-2"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania mikrobiologiczne","regulatory_area_en":"Microbiological tests","regulatory_area_zh":"微生物检测","regulatory_area_cs":"Mikrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie enterokoków metodą hodowlaną Pitné, povrchové, podzemní, odpadní vody Stanovení enterokoků kultivačně MBI-05 (ČSN EN ISO 7899-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie enterokokow metoda hodowlana Pitne, povrchove, podzemni, odpadni vody Stanoveni enterokoku kultivacne MBI-05 (CSN EN ISO 7899-2)","search_en":"Drinking, surface, ground and waste water Determination of enterococci by cultivation MBI-05 (ČSN EN ISO 7899-2)","search_zh":"饮用水、地表水、地下水、废水 培养法测定肠球菌 MBI-05 (ČSN EN ISO 7899-2)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca31d9841cf7dd818e90876a","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"2.4","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Pitné, povrchové, podzemní, odpadní vody","methodology":"Oznaczanie mikroorganizmów hodowlanych metodą hodowlaną","methodology_en":"Determination of culturable microorganisms by cultivation","methodology_zh":"培养法测定可培养微生物","methodology_cs":"Stanovení kultivovatelných mikroorganismů kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mikroorganizmów hodowlanych metodą hodowlaną","reference":"MBI-17 (ČSN EN ISO 6222)","norm_bases":["MBI-17","ČSN EN ISO 6222"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania mikrobiologiczne","regulatory_area_en":"Microbiological tests","regulatory_area_zh":"微生物检测","regulatory_area_cs":"Mikrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki Oznaczanie mikroorganizmów hodowlanych metodą hodowlaną Pitné, povrchové, podzemní, odpadní vody Stanovení kultivovatelných mikroorganismů kultivačně MBI-17 (ČSN EN ISO 6222) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki Oznaczanie mikroorganizmow hodowlanych metoda hodowlana Pitne, povrchove, podzemni, odpadni vody Stanoveni kultivovatelnych mikroorganismu kultivacne MBI-17 (CSN EN ISO 6222)","search_en":"Drinking, surface, ground and waste water Determination of culturable microorganisms by cultivation MBI-17 (ČSN EN ISO 6222)","search_zh":"饮用水、地表水、地下水、废水 培养法测定可培养微生物 MBI-17 (ČSN EN ISO 6222)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e83498786f4bfa123947d388","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"3.1","test_object":"Wody powierzchniowe i ścieki","test_object_en":"Surface and waste water","test_object_zh":"地表水和废水","test_object_cs":"Povrchové a odpadní vody","methodology":"Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metodą analizy morfologicznej z użyciem mikroskopu","methodology_en":"Determination of bioseston and phytoplankton including planktonic cyanobacteria by morphological analysis using a microscope","methodology_zh":"显微镜形态学分析法测定生物悬浮物和浮游植物（包括浮游蓝藻）","methodology_cs":"Stanovení biosestonu a fytoplanktonu včetně planktonních sinic morfologickou analýzou s použitím mikroskopu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metodą analizy morfologicznej z użyciem mikroskopu","reference":"HB-04 A (ČSN 75 7712; ČSN 75 7717; STN 75 7715; Heteša, J., Marvan, P., 2006: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV TGM)","norm_bases":["HB-04 A","ČSN 75 7712","ČSN 75 7717","STN 75 7715","Heteša, J., Marvan, P., 2006: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV TGM"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrobiologiczne","regulatory_area_en":"Hydrobiological tests","regulatory_area_zh":"水生生物检测","regulatory_area_cs":"Hydrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe i ścieki Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metodą analizy morfologicznej z użyciem mikroskopu Povrchové a odpadní vody Stanovení biosestonu a fytoplanktonu včetně planktonních sinic morfologickou analýzou s použitím mikroskopu HB-04 A (ČSN 75 7712; ČSN 75 7717; STN 75 7715; Heteša, J., Marvan, P., 2006: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV TGM) Wody powierzchniowe i scieki Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metoda analizy morfologicznej z uzyciem mikroskopu Povrchove a odpadni vody Stanoveni biosestonu a fytoplanktonu vcetne planktonnich sinic morfologickou analyzou s pouzitim mikroskopu HB-04 A (CSN 75 7712; CSN 75 7717; STN 75 7715; Hetesa, J., Marvan, P., 2006: Metodika odberu a zpracovani vzorku fytoplanktonu tekoucich vod, VUV TGM)","search_en":"Surface and waste water Determination of bioseston and phytoplankton including planktonic cyanobacteria by morphological analysis using a microscope HB-04 A (ČSN 75 7712; ČSN 75 7717; STN 75 7715; Heteša, J., Marvan, P., 2006: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV TGM)","search_zh":"地表水和废水 显微镜形态学分析法测定生物悬浮物和浮游植物（包括浮游蓝藻） HB-04 A (ČSN 75 7712; ČSN 75 7717; STN 75 7715; Heteša, J., Marvan, P., 2006: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV TGM)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a9c2629ee59a80e30aa18ebb","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"3.2","test_object":"Wody powierzchniowe i ścieki","test_object_en":"Surface and waste water","test_object_zh":"地表水和废水","test_object_cs":"Povrchové a odpadní vody","methodology":"Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metodą analizy morfologicznej z użyciem mikroskopu","methodology_en":"Determination of bioseston and phytoplankton including planktonic cyanobacteria by morphological analysis using a microscope","methodology_zh":"显微镜形态学分析法测定生物悬浮物和浮游植物（包括浮游蓝藻）","methodology_cs":"Stanovení biosestonu a fytoplanktonu včetně planktonních sinic morfologickou analýzou s použitím mikroskopu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metodą analizy morfologicznej z użyciem mikroskopu","reference":"HB-04 B (ČSN EN 15204; Komárková, J., 2006: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV TGM)","norm_bases":["HB-04 B","ČSN EN 15204","Komárková, J., 2006: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV TGM"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrobiologiczne","regulatory_area_en":"Hydrobiological tests","regulatory_area_zh":"水生生物检测","regulatory_area_cs":"Hydrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe i ścieki Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metodą analizy morfologicznej z użyciem mikroskopu Povrchové a odpadní vody Stanovení biosestonu a fytoplanktonu včetně planktonních sinic morfologickou analýzou s použitím mikroskopu HB-04 B (ČSN EN 15204; Komárková, J., 2006: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV TGM) Wody powierzchniowe i scieki Oznaczanie biosestonu i fitoplanktonu, w tym sinic planktonowych, metoda analizy morfologicznej z uzyciem mikroskopu Povrchove a odpadni vody Stanoveni biosestonu a fytoplanktonu vcetne planktonnich sinic morfologickou analyzou s pouzitim mikroskopu HB-04 B (CSN EN 15204; Komarkova, J., 2006: Metodika odberu a zpracovani vzorku fytoplanktonu stojatych vod, VUV TGM)","search_en":"Surface and waste water Determination of bioseston and phytoplankton including planktonic cyanobacteria by morphological analysis using a microscope HB-04 B (ČSN EN 15204; Komárková, J., 2006: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV TGM)","search_zh":"地表水和废水 显微镜形态学分析法测定生物悬浮物和浮游植物（包括浮游蓝藻） HB-04 B (ČSN EN 15204; Komárková, J., 2006: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV TGM)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"956f690a218ede10871e1696","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"3.3","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Oznaczanie fitobentosu i okrzemek bentosowych metodą analizy morfologicznej z użyciem mikroskopu","methodology_en":"Determination of phytobenthos and benthic diatoms by morphological analysis using a microscope","methodology_zh":"显微镜形态学分析法测定底栖植物和底栖硅藻","methodology_cs":"Stanovení fytobentosu a bentických rozsivek morfologickou analýzou s použitím mikroskopu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fitobentosu i okrzemek bentosowych metodą analizy morfologicznej z użyciem mikroskopu","reference":"HB-06 (ČSN EN 13946; ČSN EN 14407; ČSN EN 15708; STN 75 7715; Marvan, P., Heteša, J., 2006: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod, VÚV TGM; Marvan, P., Kozáková, M., 2006: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV TGM)","norm_bases":["HB-06","ČSN EN 13946","ČSN EN 14407","ČSN EN 15708","STN 75 7715","Marvan, P., Heteša, J., 2006: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod, VÚV TGM","Marvan, P., Kozáková, M., 2006: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV TGM"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrobiologiczne","regulatory_area_en":"Hydrobiological tests","regulatory_area_zh":"水生生物检测","regulatory_area_cs":"Hydrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie fitobentosu i okrzemek bentosowych metodą analizy morfologicznej z użyciem mikroskopu Povrchové vody Stanovení fytobentosu a bentických rozsivek morfologickou analýzou s použitím mikroskopu HB-06 (ČSN EN 13946; ČSN EN 14407; ČSN EN 15708; STN 75 7715; Marvan, P., Heteša, J., 2006: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod, VÚV TGM; Marvan, P., Kozáková, M., 2006: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV TGM) Wody powierzchniowe Oznaczanie fitobentosu i okrzemek bentosowych metoda analizy morfologicznej z uzyciem mikroskopu Povrchove vody Stanoveni fytobentosu a bentickych rozsivek morfologickou analyzou s pouzitim mikroskopu HB-06 (CSN EN 13946; CSN EN 14407; CSN EN 15708; STN 75 7715; Marvan, P., Hetesa, J., 2006: Metodika odberu a zpracovani vzorku fytobentosu tekoucich vod, VUV TGM; Marvan, P., Kozakova, M., 2006: Metodika odberu a zpracovani vzorku fytobentosu stojatych vod, VUV TGM)","search_en":"Surface water Determination of phytobenthos and benthic diatoms by morphological analysis using a microscope HB-06 (ČSN EN 13946; ČSN EN 14407; ČSN EN 15708; STN 75 7715; Marvan, P., Heteša, J., 2006: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod, VÚV TGM; Marvan, P., Kozáková, M., 2006: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV TGM)","search_zh":"地表水 显微镜形态学分析法测定底栖植物和底栖硅藻 HB-06 (ČSN EN 13946; ČSN EN 14407; ČSN EN 15708; STN 75 7715; Marvan, P., Heteša, J., 2006: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod, VÚV TGM; Marvan, P., Kozáková, M., 2006: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV TGM)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7961d27320f5d312ecb32055","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"3.4","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Oznaczanie makrozoobentosu metodą analizy morfologicznej z użyciem mikroskopu","methodology_en":"Determination of macrozoobenthos by morphological analysis using a microscope","methodology_zh":"显微镜形态学分析法测定大型底栖动物","methodology_cs":"Stanovení makrozoobentosu morfologickou analýzou s použitím mikroskopu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie makrozoobentosu metodą analizy morfologicznej z użyciem mikroskopu","reference":"HB-08 (ČSN 75 7701; ČSN EN ISO 10870; ČSN EN 16150; ČSN 75 7714; ČSN EN 15196; STN 75 7715; Adámek, Z., 2006: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV TGM; Kokeš, J., Němejcová, D., 2006: Metodika odběru a zpracování vzorků makrozoobentosu tekoucích vod metodou Perla, VÚV TGM; Němejcová, D. a kol., 2013: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV TGM)","norm_bases":["HB-08","ČSN 75 7701","ČSN EN ISO 10870","ČSN EN 16150","ČSN 75 7714","ČSN EN 15196","STN 75 7715","Adámek, Z., 2006: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV TGM","Kokeš, J., Němejcová, D., 2006: Metodika odběru a zpracování vzorků makrozoobentosu tekoucích vod metodou Perla, VÚV TGM","Němejcová, D. a kol., 2013: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV TGM"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrobiologiczne","regulatory_area_en":"Hydrobiological tests","regulatory_area_zh":"水生生物检测","regulatory_area_cs":"Hydrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie makrozoobentosu metodą analizy morfologicznej z użyciem mikroskopu Povrchové vody Stanovení makrozoobentosu morfologickou analýzou s použitím mikroskopu HB-08 (ČSN 75 7701; ČSN EN ISO 10870; ČSN EN 16150; ČSN 75 7714; ČSN EN 15196; STN 75 7715; Adámek, Z., 2006: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV TGM; Kokeš, J., Němejcová, D., 2006: Metodika odběru a zpracování vzorků makrozoobentosu tekoucích vod metodou Perla, VÚV TGM; Němejcová, D. a kol., 2013: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV TGM) Wody powierzchniowe Oznaczanie makrozoobentosu metoda analizy morfologicznej z uzyciem mikroskopu Povrchove vody Stanoveni makrozoobentosu morfologickou analyzou s pouzitim mikroskopu HB-08 (CSN 75 7701; CSN EN ISO 10870; CSN EN 16150; CSN 75 7714; CSN EN 15196; STN 75 7715; Adamek, Z., 2006: Metodika odberu a zpracovani vzorku makrozoobentosu stojatych vod, VUV TGM; Kokes, J., Nemejcova, D., 2006: Metodika odberu a zpracovani vzorku makrozoobentosu tekoucich vod metodou Perla, VUV TGM; Nemejcova, D. a kol., 2013: Metodika odberu a zpracovani vzorku makrozoobentosu velkych nebroditelnych rek, VUV TGM)","search_en":"Surface water Determination of macrozoobenthos by morphological analysis using a microscope HB-08 (ČSN 75 7701; ČSN EN ISO 10870; ČSN EN 16150; ČSN 75 7714; ČSN EN 15196; STN 75 7715; Adámek, Z., 2006: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV TGM; Kokeš, J., Němejcová, D., 2006: Metodika odběru a zpracování vzorků makrozoobentosu tekoucích vod metodou Perla, VÚV TGM; Němejcová, D. a kol., 2013: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV TGM)","search_zh":"地表水 显微镜形态学分析法测定大型底栖动物 HB-08 (ČSN 75 7701; ČSN EN ISO 10870; ČSN EN 16150; ČSN 75 7714; ČSN EN 15196; STN 75 7715; Adámek, Z., 2006: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV TGM; Kokeš, J., Němejcová, D., 2006: Metodika odběru a zpracování vzorků makrozoobentosu tekoucích vod metodou Perla, VÚV TGM; Němejcová, D. a kol., 2013: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV TGM)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f93bbfead8ea89a405d46bf","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"3.5","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface and waste water","test_object_zh":"地表水、废水","test_object_cs":"Povrchové, odpadní vody","methodology":"Oznaczanie indeksu saprobowości obliczeniowo","methodology_en":"Determination of the saprobic index by calculation","methodology_zh":"计算法测定污水生物指数","methodology_cs":"Stanovení saprobního indexu výpočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie indeksu saprobowości obliczeniowo","reference":"HB-09 (ČSN 75 7716)","norm_bases":["HB-09","ČSN 75 7716"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrobiologiczne","regulatory_area_en":"Hydrobiological tests","regulatory_area_zh":"水生生物检测","regulatory_area_cs":"Hydrobiologické zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie indeksu saprobowości obliczeniowo Povrchové, odpadní vody Stanovení saprobního indexu výpočtem HB-09 (ČSN 75 7716) Wody powierzchniowe, scieki Oznaczanie indeksu saprobowosci obliczeniowo Povrchove, odpadni vody Stanoveni saprobniho indexu vypoctem HB-09 (CSN 75 7716)","search_en":"Surface and waste water Determination of the saprobic index by calculation HB-09 (ČSN 75 7716)","search_zh":"地表水、废水 计算法测定污水生物指数 HB-09 (ČSN 75 7716)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75da3d982664a9b8854db042","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"3.6","test_object":"Wody powierzchniowe, podziemne, peryfiton (obrosty)","test_object_en":"Surface and ground water, periphyton","test_object_zh":"地表水、地下水、附着生物","test_object_cs":"Povrchové, podzemní vody, nárosty","methodology":"Oznaczanie stężenia chlorofilu-a metodą spektrofotometryczną","methodology_en":"Determination of chlorophyll-a concentration spectrophotometrically","methodology_zh":"分光光度法测定叶绿素a浓度","methodology_cs":"Stanovení koncentrace chlorofylu-a spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia chlorofilu-a metodą spektrofotometryczną","reference":"HB-10 (ČSN ISO 10260)","norm_bases":["HB-10","ČSN ISO 10260"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Badania hydrobiologiczne","regulatory_area_en":"Hydrobiological tests","regulatory_area_zh":"水生生物检测","regulatory_area_cs":"Hydrobiologické zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, podziemne, peryfiton (obrosty) Oznaczanie stężenia chlorofilu-a metodą spektrofotometryczną Povrchové, podzemní vody, nárosty Stanovení koncentrace chlorofylu-a spektrofotometricky HB-10 (ČSN ISO 10260) Wody powierzchniowe, podziemne, peryfiton (obrosty) Oznaczanie stezenia chlorofilu-a metoda spektrofotometryczna Povrchove, podzemni vody, narosty Stanoveni koncentrace chlorofylu-a spektrofotometricky HB-10 (CSN ISO 10260)","search_en":"Surface and ground water, periphyton Determination of chlorophyll-a concentration spectrophotometrically HB-10 (ČSN ISO 10260)","search_zh":"地表水、地下水、附着生物 分光光度法测定叶绿素a浓度 HB-10 (ČSN ISO 10260)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f1628ef1a8b9504254b6bede","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"4.1","test_object":"Wody przeznaczone do spożycia","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitné vody","methodology":"Oznaczanie mikroplastików metodą spektrometrii w podczerwieni z transformacją Fouriera","methodology_en":"Determination of microplastics by Fourier transform infrared spectrometry","methodology_zh":"傅里叶变换红外光谱法测定微塑料","methodology_cs":"Stanovení mikroplastů metodou infračervené spektrometrie s Fourierovou transformací","parameters":[{"name":"Polipropylen (PP)","range":""},{"name":"Polietylen (PE)","range":""},{"name":"Poli(chlorek winylu) (PVC)","range":""},{"name":"Poliuretan (PU)","range":""},{"name":"Poli(tereftalan etylenu) (PET)","range":""},{"name":"Polistyren (PS)","range":""},{"name":"Kopolimer akrylonitryl-butadien-styren (ABS)","range":""},{"name":"Poliamid (PA)","range":""},{"name":"Poliwęglan (PC)","range":""},{"name":"Poli(metakrylan metylu) (PMMA)","range":""},{"name":"Polioksymetylen (POM)","range":""},{"name":"Octan celulozy (CA)","range":""},{"name":"Kopolimer etylen-octan winylu (EVAc)","range":""},{"name":"Kopolimer etylen-alkohol winylowy (EVOH)","range":""},{"name":"Poliakrylonitryl (PAN)","range":""},{"name":"Poli(tereftalan butylenu) (PBT)","range":""},{"name":"Polieteroeteroketon (PEEK)","range":""},{"name":"Polifenylosulfon (PPSU)","range":""},{"name":"Polisulfon (PSU)","range":""},{"name":"Silikon","range":""},{"name":"Polilaktyd (PLA)","range":""}],"parameters_en":[{"name":"Polypropylene (PP)","range":""},{"name":"Polyethylene (PE)","range":""},{"name":"Polyvinyl chloride (PVC)","range":""},{"name":"Polyurethane (PU)","range":""},{"name":"Polyethylene terephthalate (PET)","range":""},{"name":"Polystyrene (PS)","range":""},{"name":"Acrylonitrile butadiene styrene (ABS)","range":""},{"name":"Polyamide (PA)","range":""},{"name":"Polycarbonate (PC)","range":""},{"name":"Polymethyl methacrylate (PMMA)","range":""},{"name":"Polyoxymethylene (POM)","range":""},{"name":"Cellulose acetate (CA)","range":""},{"name":"Ethylene-vinyl acetate (EVAc)","range":""},{"name":"Ethylene vinyl alcohol (EVOH)","range":""},{"name":"Polyacrylonitrile (PAN)","range":""},{"name":"Polybutylene terephthalate (PBT)","range":""},{"name":"Polyether ether ketone (PEEK)","range":""},{"name":"Polyphenylsulfone (PPSU)","range":""},{"name":"Polysulfone (PSU)","range":""},{"name":"Silicone","range":""},{"name":"Polylactic acid (PLA)","range":""}],"parameters_zh":[{"name":"聚丙烯（PP）","range":""},{"name":"聚乙烯（PE）","range":""},{"name":"聚氯乙烯（PVC）","range":""},{"name":"聚氨酯（PU）","range":""},{"name":"聚对苯二甲酸乙二醇酯（PET）","range":""},{"name":"聚苯乙烯（PS）","range":""},{"name":"丙烯腈-丁二烯-苯乙烯共聚物（ABS）","range":""},{"name":"聚酰胺（PA）","range":""},{"name":"聚碳酸酯（PC）","range":""},{"name":"聚甲基丙烯酸甲酯（PMMA）","range":""},{"name":"聚甲醛（POM）","range":""},{"name":"醋酸纤维素（CA）","range":""},{"name":"乙烯-醋酸乙烯酯共聚物（EVAc）","range":""},{"name":"乙烯-乙烯醇共聚物（EVOH）","range":""},{"name":"聚丙烯腈（PAN）","range":""},{"name":"聚对苯二甲酸丁二醇酯（PBT）","range":""},{"name":"聚醚醚酮（PEEK）","range":""},{"name":"聚亚苯基砜（PPSU）","range":""},{"name":"聚砜（PSU）","range":""},{"name":"有机硅","range":""},{"name":"聚乳酸（PLA）","range":""}],"parameters_cs":[{"name":"PP","range":""},{"name":"PE","range":""},{"name":"PVC","range":""},{"name":"PU","range":""},{"name":"PET","range":""},{"name":"PS","range":""},{"name":"ABS","range":""},{"name":"PA","range":""},{"name":"PC","range":""},{"name":"PMMA","range":""},{"name":"POM","range":""},{"name":"CA","range":""},{"name":"EVAc","range":""},{"name":"EVOH","range":""},{"name":"PAN","range":""},{"name":"PBT","range":""},{"name":"PEEK","range":""},{"name":"PPSU","range":""},{"name":"PSU","range":""},{"name":"silicone","range":""},{"name":"PLA","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mikroplastików metodą spektrometrii w podczerwieni z transformacją Fouriera\nZakres:\nPolipropylen (PP)\nPolietylen (PE)\nPoli(chlorek winylu) (PVC)\nPoliuretan (PU)\nPoli(tereftalan etylenu) (PET)\nPolistyren (PS)\nKopolimer akrylonitryl-butadien-styren (ABS)\nPoliamid (PA)\nPoliwęglan (PC)\nPoli(metakrylan metylu) (PMMA)\nPolioksymetylen (POM)\nOctan celulozy (CA)\nKopolimer etylen-octan winylu (EVAc)\nKopolimer etylen-alkohol winylowy (EVOH)\nPoliakrylonitryl (PAN)\nPoli(tereftalan butylenu) (PBT)\nPolieteroeteroketon (PEEK)\nPolifenylosulfon (PPSU)\nPolisulfon (PSU)\nSilikon\nPolilaktyd (PLA)","reference":"MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě)","norm_bases":["MP-01","Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Oznaczanie mikroplastików","regulatory_area_en":"Determination of microplastics","regulatory_area_zh":"微塑料测定","regulatory_area_cs":"Stanovení mikroplastů","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia Oznaczanie mikroplastików metodą spektrometrii w podczerwieni z transformacją Fouriera Polipropylen (PP)  Polietylen (PE)  Poli(chlorek winylu) (PVC)  Poliuretan (PU)  Poli(tereftalan etylenu) (PET)  Polistyren (PS)  Kopolimer akrylonitryl-butadien-styren (ABS)  Poliamid (PA)  Poliwęglan (PC)  Poli(metakrylan metylu) (PMMA)  Polioksymetylen (POM)  Octan celulozy (CA)  Kopolimer etylen-octan winylu (EVAc)  Kopolimer etylen-alkohol winylowy (EVOH)  Poliakrylonitryl (PAN)  Poli(tereftalan butylenu) (PBT)  Polieteroeteroketon (PEEK)  Polifenylosulfon (PPSU)  Polisulfon (PSU)  Silikon  Polilaktyd (PLA)  Pitné vody Stanovení mikroplastů metodou infračervené spektrometrie s Fourierovou transformací PP  PE  PVC  PU  PET  PS  ABS  PA  PC  PMMA  POM  CA  EVAc  EVOH  PAN  PBT  PEEK  PPSU  PSU  silicone  PLA  MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě) Wody przeznaczone do spozycia Oznaczanie mikroplastikow metoda spektrometrii w podczerwieni z transformacja Fouriera Polipropylen (PP)  Polietylen (PE)  Poli(chlorek winylu) (PVC)  Poliuretan (PU)  Poli(tereftalan etylenu) (PET)  Polistyren (PS)  Kopolimer akrylonitryl-butadien-styren (ABS)  Poliamid (PA)  Poliweglan (PC)  Poli(metakrylan metylu) (PMMA)  Polioksymetylen (POM)  Octan celulozy (CA)  Kopolimer etylen-octan winylu (EVAc)  Kopolimer etylen-alkohol winylowy (EVOH)  Poliakrylonitryl (PAN)  Poli(tereftalan butylenu) (PBT)  Polieteroeteroketon (PEEK)  Polifenylosulfon (PPSU)  Polisulfon (PSU)  Silikon  Polilaktyd (PLA)  Pitne vody Stanoveni mikroplastu metodou infracervene spektrometrie s Fourierovou transformaci PP  PE  PVC  PU  PET  PS  ABS  PA  PC  PMMA  POM  CA  EVAc  EVOH  PAN  PBT  PEEK  PPSU  PSU  silicone  PLA  MP-01 (Rozhodnuti Komise v prenesene pravomoci (EU) 2024/1441 ze dne 11. brezna 2024, kterym se doplnuje smernice Evropskeho parlamentu a Rady (EU) 2020/2184 stanovenim metodiky pro mereni mikroplastu ve vode urcene k lidske spotrebe)","search_en":"Drinking water Determination of microplastics by Fourier transform infrared spectrometry Polypropylene (PP)  Polyethylene (PE)  Polyvinyl chloride (PVC)  Polyurethane (PU)  Polyethylene terephthalate (PET)  Polystyrene (PS)  Acrylonitrile butadiene styrene (ABS)  Polyamide (PA)  Polycarbonate (PC)  Polymethyl methacrylate (PMMA)  Polyoxymethylene (POM)  Cellulose acetate (CA)  Ethylene-vinyl acetate (EVAc)  Ethylene vinyl alcohol (EVOH)  Polyacrylonitrile (PAN)  Polybutylene terephthalate (PBT)  Polyether ether ketone (PEEK)  Polyphenylsulfone (PPSU)  Polysulfone (PSU)  Silicone  Polylactic acid (PLA)  MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě)","search_zh":"饮用水 傅里叶变换红外光谱法测定微塑料 聚丙烯（PP）  聚乙烯（PE）  聚氯乙烯（PVC）  聚氨酯（PU）  聚对苯二甲酸乙二醇酯（PET）  聚苯乙烯（PS）  丙烯腈-丁二烯-苯乙烯共聚物（ABS）  聚酰胺（PA）  聚碳酸酯（PC）  聚甲基丙烯酸甲酯（PMMA）  聚甲醛（POM）  醋酸纤维素（CA）  乙烯-醋酸乙烯酯共聚物（EVAc）  乙烯-乙烯醇共聚物（EVOH）  聚丙烯腈（PAN）  聚对苯二甲酸丁二醇酯（PBT）  聚醚醚酮（PEEK）  聚亚苯基砜（PPSU）  聚砜（PSU）  有机硅  聚乳酸（PLA）  MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1aa9948db34baabdfc9372fb","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"4.1","test_object":"Wody przeznaczone do spożycia","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitné vody","methodology":"Oznaczanie mikroplastików metodą spektrometrii w podczerwieni z transformacją Fouriera","methodology_en":"Determination of microplastics by Fourier transform infrared spectrometry","methodology_zh":"傅里叶变换红外光谱法测定微塑料","methodology_cs":"Stanovení mikroplastů metodou infračervené spektrometrie s Fourierovou transformací","parameters":[{"name":"Polipropylen (PP)","range":""},{"name":"Polietylen (PE)","range":""},{"name":"Poli(chlorek winylu) (PVC)","range":""},{"name":"Poliuretan (PU)","range":""},{"name":"Poli(tereftalan etylenu) (PET)","range":""},{"name":"Polistyren (PS)","range":""},{"name":"Kopolimer akrylonitryl-butadien-styren (ABS)","range":""},{"name":"Poliamid (PA)","range":""},{"name":"Poliwęglan (PC)","range":""},{"name":"Poli(metakrylan metylu) (PMMA)","range":""},{"name":"Polioksymetylen (POM)","range":""},{"name":"Octan celulozy (CA)","range":""},{"name":"Kopolimer etylen-octan winylu (EVAc)","range":""},{"name":"Kopolimer etylen-alkohol winylowy (EVOH)","range":""},{"name":"Poliakrylonitryl (PAN)","range":""},{"name":"Poli(tereftalan butylenu) (PBT)","range":""},{"name":"Polieteroeteroketon (PEEK)","range":""},{"name":"Polifenylosulfon (PPSU)","range":""},{"name":"Polisulfon (PSU)","range":""},{"name":"Silikon","range":""},{"name":"Polilaktyd (PLA)","range":""}],"parameters_en":[{"name":"Polypropylene (PP)","range":""},{"name":"Polyethylene (PE)","range":""},{"name":"Polyvinyl chloride (PVC)","range":""},{"name":"Polyurethane (PU)","range":""},{"name":"Polyethylene terephthalate (PET)","range":""},{"name":"Polystyrene (PS)","range":""},{"name":"Acrylonitrile butadiene styrene (ABS)","range":""},{"name":"Polyamide (PA)","range":""},{"name":"Polycarbonate (PC)","range":""},{"name":"Polymethyl methacrylate (PMMA)","range":""},{"name":"Polyoxymethylene (POM)","range":""},{"name":"Cellulose acetate (CA)","range":""},{"name":"Ethylene-vinyl acetate (EVAc)","range":""},{"name":"Ethylene vinyl alcohol (EVOH)","range":""},{"name":"Polyacrylonitrile (PAN)","range":""},{"name":"Polybutylene terephthalate (PBT)","range":""},{"name":"Polyether ether ketone (PEEK)","range":""},{"name":"Polyphenylsulfone (PPSU)","range":""},{"name":"Polysulfone (PSU)","range":""},{"name":"Silicone","range":""},{"name":"Polylactic acid (PLA)","range":""}],"parameters_zh":[{"name":"聚丙烯（PP）","range":""},{"name":"聚乙烯（PE）","range":""},{"name":"聚氯乙烯（PVC）","range":""},{"name":"聚氨酯（PU）","range":""},{"name":"聚对苯二甲酸乙二醇酯（PET）","range":""},{"name":"聚苯乙烯（PS）","range":""},{"name":"丙烯腈-丁二烯-苯乙烯共聚物（ABS）","range":""},{"name":"聚酰胺（PA）","range":""},{"name":"聚碳酸酯（PC）","range":""},{"name":"聚甲基丙烯酸甲酯（PMMA）","range":""},{"name":"聚甲醛（POM）","range":""},{"name":"醋酸纤维素（CA）","range":""},{"name":"乙烯-醋酸乙烯酯共聚物（EVAc）","range":""},{"name":"乙烯-乙烯醇共聚物（EVOH）","range":""},{"name":"聚丙烯腈（PAN）","range":""},{"name":"聚对苯二甲酸丁二醇酯（PBT）","range":""},{"name":"聚醚醚酮（PEEK）","range":""},{"name":"聚亚苯基砜（PPSU）","range":""},{"name":"聚砜（PSU）","range":""},{"name":"有机硅","range":""},{"name":"聚乳酸（PLA）","range":""}],"parameters_cs":[{"name":"PP","range":""},{"name":"PE","range":""},{"name":"PVC","range":""},{"name":"PU","range":""},{"name":"PET","range":""},{"name":"PS","range":""},{"name":"ABS","range":""},{"name":"PA","range":""},{"name":"PC","range":""},{"name":"PMMA","range":""},{"name":"POM","range":""},{"name":"CA","range":""},{"name":"EVAc","range":""},{"name":"EVOH","range":""},{"name":"PAN","range":""},{"name":"PBT","range":""},{"name":"PEEK","range":""},{"name":"PPSU","range":""},{"name":"PSU","range":""},{"name":"silicone","range":""},{"name":"PLA","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mikroplastików metodą spektrometrii w podczerwieni z transformacją Fouriera\nZakres:\nPolipropylen (PP)\nPolietylen (PE)\nPoli(chlorek winylu) (PVC)\nPoliuretan (PU)\nPoli(tereftalan etylenu) (PET)\nPolistyren (PS)\nKopolimer akrylonitryl-butadien-styren (ABS)\nPoliamid (PA)\nPoliwęglan (PC)\nPoli(metakrylan metylu) (PMMA)\nPolioksymetylen (POM)\nOctan celulozy (CA)\nKopolimer etylen-octan winylu (EVAc)\nKopolimer etylen-alkohol winylowy (EVOH)\nPoliakrylonitryl (PAN)\nPoli(tereftalan butylenu) (PBT)\nPolieteroeteroketon (PEEK)\nPolifenylosulfon (PPSU)\nPolisulfon (PSU)\nSilikon\nPolilaktyd (PLA)","reference":"MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě)","norm_bases":["MP-01","Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Oznaczanie mikroplastików","regulatory_area_en":"Determination of microplastics","regulatory_area_zh":"微塑料测定","regulatory_area_cs":"Stanovení mikroplastů","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia Oznaczanie mikroplastików metodą spektrometrii w podczerwieni z transformacją Fouriera Polipropylen (PP)  Polietylen (PE)  Poli(chlorek winylu) (PVC)  Poliuretan (PU)  Poli(tereftalan etylenu) (PET)  Polistyren (PS)  Kopolimer akrylonitryl-butadien-styren (ABS)  Poliamid (PA)  Poliwęglan (PC)  Poli(metakrylan metylu) (PMMA)  Polioksymetylen (POM)  Octan celulozy (CA)  Kopolimer etylen-octan winylu (EVAc)  Kopolimer etylen-alkohol winylowy (EVOH)  Poliakrylonitryl (PAN)  Poli(tereftalan butylenu) (PBT)  Polieteroeteroketon (PEEK)  Polifenylosulfon (PPSU)  Polisulfon (PSU)  Silikon  Polilaktyd (PLA)  Pitné vody Stanovení mikroplastů metodou infračervené spektrometrie s Fourierovou transformací PP  PE  PVC  PU  PET  PS  ABS  PA  PC  PMMA  POM  CA  EVAc  EVOH  PAN  PBT  PEEK  PPSU  PSU  silicone  PLA  MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě) Wody przeznaczone do spozycia Oznaczanie mikroplastikow metoda spektrometrii w podczerwieni z transformacja Fouriera Polipropylen (PP)  Polietylen (PE)  Poli(chlorek winylu) (PVC)  Poliuretan (PU)  Poli(tereftalan etylenu) (PET)  Polistyren (PS)  Kopolimer akrylonitryl-butadien-styren (ABS)  Poliamid (PA)  Poliweglan (PC)  Poli(metakrylan metylu) (PMMA)  Polioksymetylen (POM)  Octan celulozy (CA)  Kopolimer etylen-octan winylu (EVAc)  Kopolimer etylen-alkohol winylowy (EVOH)  Poliakrylonitryl (PAN)  Poli(tereftalan butylenu) (PBT)  Polieteroeteroketon (PEEK)  Polifenylosulfon (PPSU)  Polisulfon (PSU)  Silikon  Polilaktyd (PLA)  Pitne vody Stanoveni mikroplastu metodou infracervene spektrometrie s Fourierovou transformaci PP  PE  PVC  PU  PET  PS  ABS  PA  PC  PMMA  POM  CA  EVAc  EVOH  PAN  PBT  PEEK  PPSU  PSU  silicone  PLA  MP-01 (Rozhodnuti Komise v prenesene pravomoci (EU) 2024/1441 ze dne 11. brezna 2024, kterym se doplnuje smernice Evropskeho parlamentu a Rady (EU) 2020/2184 stanovenim metodiky pro mereni mikroplastu ve vode urcene k lidske spotrebe)","search_en":"Drinking water Determination of microplastics by Fourier transform infrared spectrometry Polypropylene (PP)  Polyethylene (PE)  Polyvinyl chloride (PVC)  Polyurethane (PU)  Polyethylene terephthalate (PET)  Polystyrene (PS)  Acrylonitrile butadiene styrene (ABS)  Polyamide (PA)  Polycarbonate (PC)  Polymethyl methacrylate (PMMA)  Polyoxymethylene (POM)  Cellulose acetate (CA)  Ethylene-vinyl acetate (EVAc)  Ethylene vinyl alcohol (EVOH)  Polyacrylonitrile (PAN)  Polybutylene terephthalate (PBT)  Polyether ether ketone (PEEK)  Polyphenylsulfone (PPSU)  Polysulfone (PSU)  Silicone  Polylactic acid (PLA)  MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě)","search_zh":"饮用水 傅里叶变换红外光谱法测定微塑料 聚丙烯（PP）  聚乙烯（PE）  聚氯乙烯（PVC）  聚氨酯（PU）  聚对苯二甲酸乙二醇酯（PET）  聚苯乙烯（PS）  丙烯腈-丁二烯-苯乙烯共聚物（ABS）  聚酰胺（PA）  聚碳酸酯（PC）  聚甲基丙烯酸甲酯（PMMA）  聚甲醛（POM）  醋酸纤维素（CA）  乙烯-醋酸乙烯酯共聚物（EVAc）  乙烯-乙烯醇共聚物（EVOH）  聚丙烯腈（PAN）  聚对苯二甲酸丁二醇酯（PBT）  聚醚醚酮（PEEK）  聚亚苯基砜（PPSU）  聚砜（PSU）  有机硅  聚乳酸（PLA）  MP-01 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"856ef3127956e42f5e197e5f","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek wód powierzchniowych ręcznie i automatycznym próbnikiem","methodology_en":"Sampling of surface water manually and with an automatic sampler","methodology_zh":"手动和自动采样器地表水采样","methodology_cs":"Odběr vzorků povrchových vod manuálně a automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych ręcznie i automatycznym próbnikiem","reference":"OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458)","norm_bases":["OV-01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14","ČSN ISO 5667-4","ČSN EN ISO 19458"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych ręcznie i automatycznym próbnikiem Povrchové vody Odběr vzorků povrchových vod manuálně a automatickým vzorkovačem OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458) Wody powierzchniowe Pobieranie probek wod powierzchniowych recznie i automatycznym probnikiem Povrchove vody Odber vzorku povrchovych vod manualne a automatickym vzorkovacem OV-01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-6; CSN EN ISO 5667-14; CSN ISO 5667-4; CSN EN ISO 19458)","search_en":"Surface water Sampling of surface water manually and with an automatic sampler OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458)","search_zh":"地表水 手动和自动采样器地表水采样 OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"887e3029a78ef0bc29ce5b7f","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"1","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek wód powierzchniowych ręcznie i automatycznym próbnikiem","methodology_en":"Sampling of surface water manually and with an automatic sampler","methodology_zh":"手动和自动采样器地表水采样","methodology_cs":"Odběr vzorků povrchových vod manuálně a automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych ręcznie i automatycznym próbnikiem","reference":"OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458)","norm_bases":["OV-01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14","ČSN ISO 5667-4","ČSN EN ISO 19458"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych ręcznie i automatycznym próbnikiem Povrchové vody Odběr vzorků povrchových vod manuálně a automatickým vzorkovačem OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458) Wody powierzchniowe Pobieranie probek wod powierzchniowych recznie i automatycznym probnikiem Povrchove vody Odber vzorku povrchovych vod manualne a automatickym vzorkovacem OV-01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-6; CSN EN ISO 5667-14; CSN ISO 5667-4; CSN EN ISO 19458)","search_en":"Surface water Sampling of surface water manually and with an automatic sampler OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458)","search_zh":"地表水 手动和自动采样器地表水采样 OV-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4b79c556373acfb767de439","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","methodology_en":"Sampling of waste water manually and with an automatic sampler","methodology_zh":"手动和自动采样器废水采样","methodology_cs":"Odběr vzorků odpadních vod manuálně a automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","reference":"OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315)","norm_bases":["OV-02","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-14","ČSN ISO 5667-10","ČSN EN ISO 19458","ČSN 75 7315"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem Odpadní vody Odběr vzorků odpadních vod manuálně a automatickým vzorkovačem OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315) Scieki Pobieranie probek sciekow recznie i automatycznym probnikiem Odpadni vody Odber vzorku odpadnich vod manualne a automatickym vzorkovacem OV-02 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-14; CSN ISO 5667-10; CSN EN ISO 19458; CSN 75 7315)","search_en":"Waste water Sampling of waste water manually and with an automatic sampler OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315)","search_zh":"废水 手动和自动采样器废水采样 OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d4661ffbadb87edca2640046","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","methodology_en":"Sampling of waste water manually and with an automatic sampler","methodology_zh":"手动和自动采样器废水采样","methodology_cs":"Odběr vzorků odpadních vod manuálně a automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","reference":"OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315)","norm_bases":["OV-02","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-14","ČSN ISO 5667-10","ČSN EN ISO 19458","ČSN 75 7315"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem Odpadní vody Odběr vzorků odpadních vod manuálně a automatickým vzorkovačem OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315) Scieki Pobieranie probek sciekow recznie i automatycznym probnikiem Odpadni vody Odber vzorku odpadnich vod manualne a automatickym vzorkovacem OV-02 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-14; CSN ISO 5667-10; CSN EN ISO 19458; CSN 75 7315)","search_en":"Waste water Sampling of waste water manually and with an automatic sampler OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315)","search_zh":"废水 手动和自动采样器废水采样 OV-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN EN ISO 19458; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c6aa0d6b7ea6cc9a1ad168b","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"3","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Ręczne pobieranie próbek hydrobiologicznych (bioseston, fitoplankton, fitobentos i makrozoobentos)","methodology_en":"Manual sampling of hydrobiological samples (bioseston, phytoplankton, phytobenthos and macrozoobenthos)","methodology_zh":"手动采集水生生物样品（生物悬浮物、浮游植物、底栖植物和大型底栖动物）","methodology_cs":"Odběr hydrobiologických vzorků manuálně (bioseston, fytoplankton, fytobentos a makrozoobentos)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ręczne pobieranie próbek hydrobiologicznych (bioseston, fitoplankton, fitobentos i makrozoobentos)","reference":"OV-05 (ČSN 75 7701; ČSN 75 7712; ČSN 75 7714; ČSN EN 13946; ČSN EN 15196; ČSN EN 15708; ČSN EN 16150; ČSN EN 16698; ČSN EN 17136; ČSN EN ISO 10870; STN 75 7715; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN ISO 5667-10; ČSN EN ISO 5667-14; HB-04 A; HB-04 B; HB-06; HB-08)","norm_bases":["OV-05","ČSN 75 7701","ČSN 75 7712","ČSN 75 7714","ČSN EN 13946","ČSN EN 15196","ČSN EN 15708","ČSN EN 16150","ČSN EN 16698","ČSN EN 17136","ČSN EN ISO 10870","STN 75 7715","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-6","ČSN ISO 5667-10","ČSN EN ISO 5667-14","HB-04 A","HB-04 B","HB-06","HB-08"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Ręczne pobieranie próbek hydrobiologicznych (bioseston, fitoplankton, fitobentos i makrozoobentos) Povrchové vody Odběr hydrobiologických vzorků manuálně (bioseston, fytoplankton, fytobentos a makrozoobentos) OV-05 (ČSN 75 7701; ČSN 75 7712; ČSN 75 7714; ČSN EN 13946; ČSN EN 15196; ČSN EN 15708; ČSN EN 16150; ČSN EN 16698; ČSN EN 17136; ČSN EN ISO 10870; STN 75 7715; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN ISO 5667-10; ČSN EN ISO 5667-14; HB-04 A; HB-04 B; HB-06; HB-08) Wody powierzchniowe Reczne pobieranie probek hydrobiologicznych (bioseston, fitoplankton, fitobentos i makrozoobentos) Povrchove vody Odber hydrobiologickych vzorku manualne (bioseston, fytoplankton, fytobentos a makrozoobentos) OV-05 (CSN 75 7701; CSN 75 7712; CSN 75 7714; CSN EN 13946; CSN EN 15196; CSN EN 15708; CSN EN 16150; CSN EN 16698; CSN EN 17136; CSN EN ISO 10870; STN 75 7715; CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN EN ISO 5667-6; CSN ISO 5667-10; CSN EN ISO 5667-14; HB-04 A; HB-04 B; HB-06; HB-08)","search_en":"Surface water Manual sampling of hydrobiological samples (bioseston, phytoplankton, phytobenthos and macrozoobenthos) OV-05 (ČSN 75 7701; ČSN 75 7712; ČSN 75 7714; ČSN EN 13946; ČSN EN 15196; ČSN EN 15708; ČSN EN 16150; ČSN EN 16698; ČSN EN 17136; ČSN EN ISO 10870; STN 75 7715; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN ISO 5667-10; ČSN EN ISO 5667-14; HB-04 A; HB-04 B; HB-06; HB-08)","search_zh":"地表水 手动采集水生生物样品（生物悬浮物、浮游植物、底栖植物和大型底栖动物） OV-05 (ČSN 75 7701; ČSN 75 7712; ČSN 75 7714; ČSN EN 13946; ČSN EN 15196; ČSN EN 15708; ČSN EN 16150; ČSN EN 16698; ČSN EN 17136; ČSN EN ISO 10870; STN 75 7715; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN ISO 5667-10; ČSN EN ISO 5667-14; HB-04 A; HB-04 B; HB-06; HB-08)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"575017a5886b71b2185ded96","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"4","test_object":"Wody przeznaczone do spożycia","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitné vody","methodology":"Pobieranie próbek wody przeznaczonej do spożycia w celu oznaczania mikroplastików","methodology_en":"Sampling of drinking water for the determination of microplastics","methodology_zh":"用于微塑料测定的饮用水采样","methodology_cs":"Odběr vzorků pitných vod za účelem stanovení mikroplastů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody przeznaczonej do spożycia w celu oznaczania mikroplastików","reference":"OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27)","norm_bases":["OV-7","Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441","ISO 5667-27"],"lab_section":"Dział hydrochemii","lab_section_en":"Hydrochemistry Department","lab_section_zh":"水化学部","lab_section_cs":"Oddělení hydrochemie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia Pobieranie próbek wody przeznaczonej do spożycia w celu oznaczania mikroplastików Pitné vody Odběr vzorků pitných vod za účelem stanovení mikroplastů OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27) Wody przeznaczone do spozycia Pobieranie probek wody przeznaczonej do spozycia w celu oznaczania mikroplastikow Pitne vody Odber vzorku pitnych vod za ucelem stanoveni mikroplastu OV-7 (Rozhodnuti Komise v prenesene pravomoci (EU) 2024/1441 ze dne 11. brezna 2024, kterym se doplnuje smernice Evropskeho parlamentu a Rady (EU) 2020/2184 stanovenim metodiky pro mereni mikroplastu ve vode urcene k lidske spotrebe; ISO 5667-27)","search_en":"Drinking water Sampling of drinking water for the determination of microplastics OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27)","search_zh":"饮用水 用于微塑料测定的饮用水采样 OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3220690850e61f3c2e669d74","lab_id":"69ad52a4de79e566650fd59e","country":"CZ","accr_number":"1761","accr_body":"ČIA","row_label":"4","test_object":"Wody przeznaczone do spożycia","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitné vody","methodology":"Pobieranie próbek wody przeznaczonej do spożycia w celu oznaczania mikroplastików","methodology_en":"Sampling of drinking water for the determination of microplastics","methodology_zh":"用于微塑料测定的饮用水采样","methodology_cs":"Odběr vzorků pitných vod za účelem stanovení mikroplastů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody przeznaczonej do spożycia w celu oznaczania mikroplastików","reference":"OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27)","norm_bases":["OV-7","Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441","ISO 5667-27"],"lab_section":"Dział hydrobiologii","lab_section_en":"Hydrobiology Department","lab_section_zh":"水生生物学部","lab_section_cs":"Oddělení hydrobiologie","lab_address":"Mojmírovo náměstí 16, 612 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia Pobieranie próbek wody przeznaczonej do spożycia w celu oznaczania mikroplastików Pitné vody Odběr vzorků pitných vod za účelem stanovení mikroplastů OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27) Wody przeznaczone do spozycia Pobieranie probek wody przeznaczonej do spozycia w celu oznaczania mikroplastikow Pitne vody Odber vzorku pitnych vod za ucelem stanoveni mikroplastu OV-7 (Rozhodnuti Komise v prenesene pravomoci (EU) 2024/1441 ze dne 11. brezna 2024, kterym se doplnuje smernice Evropskeho parlamentu a Rady (EU) 2020/2184 stanovenim metodiky pro mereni mikroplastu ve vode urcene k lidske spotrebe; ISO 5667-27)","search_en":"Drinking water Sampling of drinking water for the determination of microplastics OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27)","search_zh":"饮用水 用于微塑料测定的饮用水采样 OV-7 (Rozhodnutí Komise v přenesené pravomoci (EU) 2024/1441 ze dne 11. března 2024, kterým se doplňuje směrnice Evropského parlamentu a Rady (EU) 2020/2184 stanovením metodiky pro měření mikroplastů ve vodě určené k lidské spotřebě; ISO 5667-27)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}