{"lab":{"_id":"69ad52a4de79e566650fd59a","accr_number":"1759","country":"CZ","accr_body":"ČIA","address":"č.p. 13, 537 01 Třibřichy","categories":["construction"],"city":"Třibřichy","imported_at":"2026-03-08T10:42:44.590Z","methods_count":22,"name":"TEPVERAM, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1759_19_2025_CS.pdf","1759_19_2025_EN.pdf"],"scope_summary":"Badania mieszanek asfaltowych, kruszyw, gruntów i konstrukcji nawierzchni drogowych, w zakresie określonym w załączniku do świadectwa.","search_text":"tepveram, s.r.o. č.p. 13, 537 01 třibřichy 1759","status":"active","updated_at":"2026-03-08T14:52:16.044Z","valid_from":"","valid_until":"14-09-2028","website":"www.tepveram.cz","map_coord":[49.966823,15.745149],"map_geo":"nominatim-city","certificate_date":"05.05.2026","certificate_no":"237/2026","certificate_replaces":"19/2025 z 20.01.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania mieszanek asfaltowych, kruszyw, gruntów i konstrukcji nawierzchni drogowych, w zakresie określonym w załączniku do świadectwa.","en":"Testing of asphalt mixtures, aggregates, soils and road pavement structures, as specified in the appendix to this Certificate.","zh":"沥青混合料、骨料、土及路面结构检测，范围见本证书附件。","cs":"Zkoušky asfaltových směsí, kameniva, zemin a konstrukcí vozovek, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"16ae2b58092c9a908239781d10b7c353551554131e62b8de7099f114e3e44b04","source_pdf_url":"https://www.cai.cz/OA/pdf/237_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"2cd8a8ba57a9c83e16e00233","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"1","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wilgotności metodą suszenia","methodology_en":"Determination of water content by drying","methodology_zh":"烘干法测定含水率","methodology_cs":"Stanovení vlhkosti sušením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą suszenia","reference":"ČSN EN ISO 17892-1","norm_bases":["ČSN EN ISO 17892-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wilgotności metodą suszenia Zeminy Stanovení vlhkosti sušením ČSN EN ISO 17892-1 Grunty Oznaczanie wilgotnosci metoda suszenia Zeminy Stanoveni vlhkosti susenim CSN EN ISO 17892-1","search_en":"Soils Determination of water content by drying ČSN EN ISO 17892-1","search_zh":"土 烘干法测定含水率 ČSN EN ISO 17892-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"51531cbe6120ea44c59240a7","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"2","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej porównawczej – Proctor standardowy","methodology_en":"Determination of reference dry density – standard Proctor","methodology_zh":"标准普氏击实法测定参考干密度","methodology_cs":"Stanovení srovnávací objemové hmotnosti – Proctor standard","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej porównawczej – Proctor standardowy","reference":"ČSN EN 13286-2, mimo čl. 7.3","norm_bases":["ČSN EN 13286-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej porównawczej – Proctor standardowy Zeminy Stanovení srovnávací objemové hmotnosti – Proctor standard ČSN EN 13286-2, mimo čl. 7.3 Grunty Oznaczanie gestosci objetosciowej porownawczej – Proctor standardowy Zeminy Stanoveni srovnavaci objemove hmotnosti – Proctor standard CSN EN 13286-2, mimo cl. 7.3","search_en":"Soils Determination of reference dry density – standard Proctor ČSN EN 13286-2, mimo čl. 7.3","search_zh":"土 标准普氏击实法测定参考干密度 ČSN EN 13286-2, mimo čl. 7.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c28a869e5e27c9416da7ed3","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"3","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej porównawczej – Proctor zmodyfikowany","methodology_en":"Determination of reference dry density – modified Proctor","methodology_zh":"修正普氏击实法测定参考干密度","methodology_cs":"Stanovení srovnávací objemové hmotnosti – Proctor modifikovaný","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej porównawczej – Proctor zmodyfikowany","reference":"ČSN EN 13286-2, mimo čl. 7.6","norm_bases":["ČSN EN 13286-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej porównawczej – Proctor zmodyfikowany Zeminy Stanovení srovnávací objemové hmotnosti – Proctor modifikovaný ČSN EN 13286-2, mimo čl. 7.6 Grunty Oznaczanie gestosci objetosciowej porownawczej – Proctor zmodyfikowany Zeminy Stanoveni srovnavaci objemove hmotnosti – Proctor modifikovany CSN EN 13286-2, mimo cl. 7.6","search_en":"Soils Determination of reference dry density – modified Proctor ČSN EN 13286-2, mimo čl. 7.6","search_zh":"土 修正普氏击实法测定参考干密度 ČSN EN 13286-2, mimo čl. 7.6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f67e1c79d065b22320aac3e8","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"4","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej – metoda wykopu (dołka)","methodology_en":"Determination of bulk density – sand replacement (pit) method","methodology_zh":"坑测法测定密度","methodology_cs":"Stanovení objemové hmotnosti – Jamková metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej – metoda wykopu (dołka)","reference":"ČSN 72 1010, metoda D-1","norm_bases":["ČSN 72 1010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej – metoda wykopu (dołka) Zeminy Stanovení objemové hmotnosti – Jamková metoda ČSN 72 1010, metoda D-1 Grunty Oznaczanie gestosci objetosciowej – metoda wykopu (dolka) Zeminy Stanoveni objemove hmotnosti – Jamkova metoda CSN 72 1010, metoda D-1","search_en":"Soils Determination of bulk density – sand replacement (pit) method ČSN 72 1010, metoda D-1","search_zh":"土 坑测法测定密度 ČSN 72 1010, metoda D-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"59998d29db291e6d6f40f570","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"5","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Laboratoryjne oznaczanie wskaźnika nośności (CBR, IBI)","methodology_en":"Laboratory determination of bearing ratio (CBR, IBI)","methodology_zh":"实验室测定承载比（CBR、IBI）","methodology_cs":"Laboratorní stanovení poměru únosnosti (CBR, IBI)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Laboratoryjne oznaczanie wskaźnika nośności (CBR, IBI)","reference":"ČSN EN 13286-47","norm_bases":["ČSN EN 13286-47"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Laboratoryjne oznaczanie wskaźnika nośności (CBR, IBI) Zeminy Laboratorní stanovení poměru únosnosti (CBR, IBI) ČSN EN 13286-47 Grunty Laboratoryjne oznaczanie wskaznika nosnosci (CBR, IBI) Zeminy Laboratorni stanoveni pomeru unosnosti (CBR, IBI) CSN EN 13286-47","search_en":"Soils Laboratory determination of bearing ratio (CBR, IBI) ČSN EN 13286-47","search_zh":"土 实验室测定承载比（CBR、IBI） ČSN EN 13286-47","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"478b27ef2e5f6430c68032c3","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"6","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Statyczne badanie obciążeniowe (płytą)","methodology_en":"Static plate load test","methodology_zh":"静态平板荷载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Statyczne badanie obciążeniowe (płytą)","reference":"ČSN 72 1006, příloha A","norm_bases":["ČSN 72 1006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Statyczne badanie obciążeniowe (płytą) Zeminy Statická zatěžovací zkouška ČSN 72 1006, příloha A Grunty Statyczne badanie obciazeniowe (plyta) Zeminy Staticka zatezovaci zkouska CSN 72 1006, priloha A","search_en":"Soils Static plate load test ČSN 72 1006, příloha A","search_zh":"土 静态平板荷载试验 ČSN 72 1006, příloha A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c81be6d678ed5a43eb48413","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"7","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Udarowe badanie obciążeniowe lekką płytą dynamiczną","methodology_en":"Impact load test with light dynamic plate","methodology_zh":"轻型动力板冲击荷载试验","methodology_cs":"Rázová zatěžovací zkouška lehkou dynamickou deskou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Udarowe badanie obciążeniowe lekką płytą dynamiczną","reference":"ČSN 73 6192, skupina C","norm_bases":["ČSN 73 6192"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Udarowe badanie obciążeniowe lekką płytą dynamiczną Zeminy Rázová zatěžovací zkouška lehkou dynamickou deskou ČSN 73 6192, skupina C Grunty Udarowe badanie obciazeniowe lekka plyta dynamiczna Zeminy Razova zatezovaci zkouska lehkou dynamickou deskou CSN 73 6192, skupina C","search_en":"Soils Impact load test with light dynamic plate ČSN 73 6192, skupina C","search_zh":"土 轻型动力板冲击荷载试验 ČSN 73 6192, skupina C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dcad5a2ef91c50640e28ec7a","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"8","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"骨料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności metodą suszenia","methodology_en":"Determination of water content by drying","methodology_zh":"烘干法测定含水率","methodology_cs":"Stanovení vlhkosti sušením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą suszenia","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności metodą suszenia Kamenivo Stanovení vlhkosti sušením ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci metoda suszenia Kamenivo Stanoveni vlhkosti susenim CSN EN 1097-5","search_en":"Aggregates Determination of water content by drying ČSN EN 1097-5","search_zh":"骨料 烘干法测定含水率 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b1bdbee69c5b39505e57d69d","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"9","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"骨料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia – analiza sitowa","methodology_en":"Determination of particle size distribution – sieving method","methodology_zh":"颗粒级配测定——筛分法","methodology_cs":"Stanovení zrnitosti – Sítový rozbor","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia – analiza sitowa","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia – analiza sitowa Kamenivo Stanovení zrnitosti – Sítový rozbor ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia – analiza sitowa Kamenivo Stanoveni zrnitosti – Sitovy rozbor CSN EN 933-1","search_en":"Aggregates Determination of particle size distribution – sieving method ČSN EN 933-1","search_zh":"骨料 颗粒级配测定——筛分法 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ee89d685ab8867fc5088894","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"11","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"骨料","test_object_cs":"Kamenivo","methodology":"Oznaczanie gęstości ziaren","methodology_en":"Determination of particle density","methodology_zh":"颗粒密度测定","methodology_cs":"Stanovení objemové hmotnosti zrn","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości ziaren","reference":"ČSN EN 1097-6, příloha A","norm_bases":["ČSN EN 1097-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie gęstości ziaren Kamenivo Stanovení objemové hmotnosti zrn ČSN EN 1097-6, příloha A Kruszywo Oznaczanie gestosci ziaren Kamenivo Stanoveni objemove hmotnosti zrn CSN EN 1097-6, priloha A","search_en":"Aggregates Determination of particle density ČSN EN 1097-6, příloha A","search_zh":"骨料 颗粒密度测定 ČSN EN 1097-6, příloha A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"28b856fabd5c282cec5e5883","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"12","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie zawartości lepiszcza rozpuszczalnego na zimno","methodology_en":"Determination of soluble binder content (cold method)","methodology_zh":"冷法测定可溶结合料含量","methodology_cs":"Stanovení obsahu rozpustného pojiva za studena","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości lepiszcza rozpuszczalnego na zimno","reference":"ČSN EN 12697-1","norm_bases":["ČSN EN 12697-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie zawartości lepiszcza rozpuszczalnego na zimno Asfaltová směs Stanovení obsahu rozpustného pojiva za studena ČSN EN 12697-1 Mieszanka asfaltowa Oznaczanie zawartosci lepiszcza rozpuszczalnego na zimno Asfaltova smes Stanoveni obsahu rozpustneho pojiva za studena CSN EN 12697-1","search_en":"Asphalt mixture Determination of soluble binder content (cold method) ČSN EN 12697-1","search_zh":"沥青混合料 冷法测定可溶结合料含量 ČSN EN 12697-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5315773c706d8c14c5d01634","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"13","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie uziarnienia na zimno","methodology_en":"Determination of particle size distribution (cold method)","methodology_zh":"冷法测定颗粒级配","methodology_cs":"Stanovení zrnitosti za studena","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia na zimno","reference":"ČSN EN 12697-2","norm_bases":["ČSN EN 12697-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie uziarnienia na zimno Asfaltová směs Stanovení zrnitosti za studena ČSN EN 12697-2 Mieszanka asfaltowa Oznaczanie uziarnienia na zimno Asfaltova smes Stanoveni zrnitosti za studena CSN EN 12697-2","search_en":"Asphalt mixture Determination of particle size distribution (cold method) ČSN EN 12697-2","search_zh":"沥青混合料 冷法测定颗粒级配 ČSN EN 12697-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70557037f4584aede6daa952","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"14","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie gęstości maksymalnej","methodology_en":"Determination of maximum density","methodology_zh":"最大密度测定","methodology_cs":"Stanovení maximální objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości maksymalnej","reference":"ČSN EN 12697-5, postup A","norm_bases":["ČSN EN 12697-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie gęstości maksymalnej Asfaltová směs Stanovení maximální objemové hmotnosti ČSN EN 12697-5, postup A Mieszanka asfaltowa Oznaczanie gestosci maksymalnej Asfaltova smes Stanoveni maximalni objemove hmotnosti CSN EN 12697-5, postup A","search_en":"Asphalt mixture Determination of maximum density ČSN EN 12697-5, postup A","search_zh":"沥青混合料 最大密度测定 ČSN EN 12697-5, postup A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"74dc3413a3d45ee0a576558b","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"15","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie gęstości objętościowej próbki asfaltowej","methodology_en":"Determination of bulk density of bituminous specimen","methodology_zh":"沥青试件毛体积密度测定","methodology_cs":"Stanovení objemové hmotnosti asfaltového zkušebního tělesa","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej próbki asfaltowej","reference":"ČSN EN 12697-6, postup B; ČSN EN 12697-30; ČSN EN 12697-29","norm_bases":["ČSN EN 12697-6","ČSN EN 12697-30","ČSN EN 12697-29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie gęstości objętościowej próbki asfaltowej Asfaltová směs Stanovení objemové hmotnosti asfaltového zkušebního tělesa ČSN EN 12697-6, postup B; ČSN EN 12697-30; ČSN EN 12697-29 Mieszanka asfaltowa Oznaczanie gestosci objetosciowej probki asfaltowej Asfaltova smes Stanoveni objemove hmotnosti asfaltoveho zkusebniho telesa CSN EN 12697-6, postup B; CSN EN 12697-30; CSN EN 12697-29","search_en":"Asphalt mixture Determination of bulk density of bituminous specimen ČSN EN 12697-6, postup B; ČSN EN 12697-30; ČSN EN 12697-29","search_zh":"沥青混合料 沥青试件毛体积密度测定 ČSN EN 12697-6, postup B; ČSN EN 12697-30; ČSN EN 12697-29","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6a86a633d64f2b56804bffc4","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"16","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie zawartości wolnych przestrzeni w mieszankach asfaltowych","methodology_en":"Determination of air voids content of asphalt mixtures","methodology_zh":"沥青混合料空隙率测定","methodology_cs":"Stanovení mezerovitosti asfaltových směsí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wolnych przestrzeni w mieszankach asfaltowych","reference":"ČSN EN 12697-8","norm_bases":["ČSN EN 12697-8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie zawartości wolnych przestrzeni w mieszankach asfaltowych Asfaltová směs Stanovení mezerovitosti asfaltových směsí ČSN EN 12697-8 Mieszanka asfaltowa Oznaczanie zawartosci wolnych przestrzeni w mieszankach asfaltowych Asfaltova smes Stanoveni mezerovitosti asfaltovych smesi CSN EN 12697-8","search_en":"Asphalt mixture Determination of air voids content of asphalt mixtures ČSN EN 12697-8","search_zh":"沥青混合料 沥青混合料空隙率测定 ČSN EN 12697-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0cda1bbadd5edb82af0d2a38","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"18","test_object":"Konstrukcje nawierzchni drogowych","test_object_en":"Road pavement structures","test_object_zh":"路面结构","test_object_cs":"Konstrukce vozovek","methodology":"Oznaczanie grubości warstwy asfaltowej na odwiertach (metoda niszcząca)","methodology_en":"Determination of asphalt layer thickness on cores (destructive method)","methodology_zh":"芯样沥青层厚度测定（破坏性方法）","methodology_cs":"Stanovení tloušťky asfaltové vrstvy na vývrtech (destruktivní metoda)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości warstwy asfaltowej na odwiertach (metoda niszcząca)","reference":"ČSN EN 12697-36, čl. 6.1","norm_bases":["ČSN EN 12697-36"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje nawierzchni drogowych Oznaczanie grubości warstwy asfaltowej na odwiertach (metoda niszcząca) Konstrukce vozovek Stanovení tloušťky asfaltové vrstvy na vývrtech (destruktivní metoda) ČSN EN 12697-36, čl. 6.1 Konstrukcje nawierzchni drogowych Oznaczanie grubosci warstwy asfaltowej na odwiertach (metoda niszczaca) Konstrukce vozovek Stanoveni tloustky asfaltove vrstvy na vyvrtech (destruktivni metoda) CSN EN 12697-36, cl. 6.1","search_en":"Road pavement structures Determination of asphalt layer thickness on cores (destructive method) ČSN EN 12697-36, čl. 6.1","search_zh":"路面结构 芯样沥青层厚度测定（破坏性方法） ČSN EN 12697-36, čl. 6.1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"390c6cdef1929195fcebb0ec","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"19","test_object":"Konstrukcje nawierzchni drogowych","test_object_en":"Road pavement structures","test_object_zh":"路面结构","test_object_cs":"Konstrukce vozovek","methodology":"Badanie ścinania – połączenie warstw asfaltowych metodą Leutnera","methodology_en":"Shear test – bond between asphalt layers according to Leutner","methodology_zh":"Leutner剪切试验——沥青层间粘结","methodology_cs":"Smyková zkouška – spojení asfaltových vrstev podle Leutnera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie ścinania – połączenie warstw asfaltowych metodą Leutnera","reference":"ČSN 73 6160, čl. 7.3","norm_bases":["ČSN 73 6160"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje nawierzchni drogowych Badanie ścinania – połączenie warstw asfaltowych metodą Leutnera Konstrukce vozovek Smyková zkouška – spojení asfaltových vrstev podle Leutnera ČSN 73 6160, čl. 7.3 Konstrukcje nawierzchni drogowych Badanie scinania – polaczenie warstw asfaltowych metoda Leutnera Konstrukce vozovek Smykova zkouska – spojeni asfaltovych vrstev podle Leutnera CSN 73 6160, cl. 7.3","search_en":"Road pavement structures Shear test – bond between asphalt layers according to Leutner ČSN 73 6160, čl. 7.3","search_zh":"路面结构 Leutner剪切试验——沥青层间粘结 ČSN 73 6160, čl. 7.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc6b864a87b20774c8eff6ed","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"20","test_object":"Konstrukcje nawierzchni drogowych","test_object_en":"Road pavement structures","test_object_zh":"路面结构","test_object_cs":"Konstrukce vozovek","methodology":"Pomiar nierówności podłużnej i poprzecznej łatą","methodology_en":"Measurement of longitudinal and transverse unevenness with a straightedge","methodology_zh":"直尺法测量纵向和横向不平整度","methodology_cs":"Měření podélné a příčné nerovnosti latí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar nierówności podłużnej i poprzecznej łatą","reference":"ČSN 73 6175, kap. 8","norm_bases":["ČSN 73 6175"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje nawierzchni drogowych Pomiar nierówności podłużnej i poprzecznej łatą Konstrukce vozovek Měření podélné a příčné nerovnosti latí ČSN 73 6175, kap. 8 Konstrukcje nawierzchni drogowych Pomiar nierownosci podluznej i poprzecznej lata Konstrukce vozovek Mereni podelne a pricne nerovnosti lati CSN 73 6175, kap. 8","search_en":"Road pavement structures Measurement of longitudinal and transverse unevenness with a straightedge ČSN 73 6175, kap. 8","search_zh":"路面结构 直尺法测量纵向和横向不平整度 ČSN 73 6175, kap. 8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cb388e8cb9998d4b9cbdcbe5","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"21","test_object":"Konstrukcje nawierzchni drogowych","test_object_en":"Road pavement structures","test_object_zh":"路面结构","test_object_cs":"Konstrukce vozovek","methodology":"Pomiar nierówności podłużnej planografem","methodology_en":"Measurement of longitudinal unevenness with a planograph","methodology_zh":"平整度仪测量纵向不平整度","methodology_cs":"Měření podélné nerovnosti planografem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar nierówności podłużnej planografem","reference":"ČSN 73 6175, kap. 9","norm_bases":["ČSN 73 6175"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje nawierzchni drogowych Pomiar nierówności podłużnej planografem Konstrukce vozovek Měření podélné nerovnosti planografem ČSN 73 6175, kap. 9 Konstrukcje nawierzchni drogowych Pomiar nierownosci podluznej planografem Konstrukce vozovek Mereni podelne nerovnosti planografem CSN 73 6175, kap. 9","search_en":"Road pavement structures Measurement of longitudinal unevenness with a planograph ČSN 73 6175, kap. 9","search_zh":"路面结构 平整度仪测量纵向不平整度 ČSN 73 6175, kap. 9","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29a6ecf425d9bc30244864ca","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"22","test_object":"Konstrukcje nawierzchni drogowych","test_object_en":"Road pavement structures","test_object_zh":"路面结构","test_object_cs":"Konstrukce vozovek","methodology":"Oznaczanie wskaźnika zagęszczenia mieszanki asfaltowej","methodology_en":"Determination of degree of compaction of asphalt mixture","methodology_zh":"沥青混合料压实度测定","methodology_cs":"Stanovení míry zhutnění asfaltové směsi","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika zagęszczenia mieszanki asfaltowej","reference":"ČSN 73 6160, čl. 7.2 a), c)","norm_bases":["ČSN 73 6160"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje nawierzchni drogowych Oznaczanie wskaźnika zagęszczenia mieszanki asfaltowej Konstrukce vozovek Stanovení míry zhutnění asfaltové směsi ČSN 73 6160, čl. 7.2 a), c) Konstrukcje nawierzchni drogowych Oznaczanie wskaznika zageszczenia mieszanki asfaltowej Konstrukce vozovek Stanoveni miry zhutneni asfaltove smesi CSN 73 6160, cl. 7.2 a), c)","search_en":"Road pavement structures Determination of degree of compaction of asphalt mixture ČSN 73 6160, čl. 7.2 a), c)","search_zh":"路面结构 沥青混合料压实度测定 ČSN 73 6160, čl. 7.2 a), c)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2ab26f24d7a34b4d1904cb03","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"23","test_object":"Konstrukcje nawierzchni drogowych","test_object_en":"Road pavement structures","test_object_zh":"路面结构","test_object_cs":"Konstrukce vozovek","methodology":"Oznaczanie zawartości wolnych przestrzeni w warstwie","methodology_en":"Determination of air voids content of the layer","methodology_zh":"层空隙率测定","methodology_cs":"Stanovení mezerovitosti vrstvy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wolnych przestrzeni w warstwie","reference":"ČSN 73 6160, čl. 7.4","norm_bases":["ČSN 73 6160"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje nawierzchni drogowych Oznaczanie zawartości wolnych przestrzeni w warstwie Konstrukce vozovek Stanovení mezerovitosti vrstvy ČSN 73 6160, čl. 7.4 Konstrukcje nawierzchni drogowych Oznaczanie zawartosci wolnych przestrzeni w warstwie Konstrukce vozovek Stanoveni mezerovitosti vrstvy CSN 73 6160, cl. 7.4","search_en":"Road pavement structures Determination of air voids content of the layer ČSN 73 6160, čl. 7.4","search_zh":"路面结构 层空隙率测定 ČSN 73 6160, čl. 7.4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44cea847be4b9b8ba0d00304","lab_id":"69ad52a4de79e566650fd59a","country":"CZ","accr_number":"1759","accr_body":"ČIA","row_label":"24","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wskaźnika zagęszczenia","methodology_en":"Determination of degree of compaction","methodology_zh":"压实度测定","methodology_cs":"Stanovení míry zhutnění","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika zagęszczenia","reference":"ČSN 72 1006, čl. 4.2.1.1","norm_bases":["ČSN 72 1006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wskaźnika zagęszczenia Zeminy Stanovení míry zhutnění ČSN 72 1006, čl. 4.2.1.1 Grunty Oznaczanie wskaznika zageszczenia Zeminy Stanoveni miry zhutneni CSN 72 1006, cl. 4.2.1.1","search_en":"Soils Determination of degree of compaction ČSN 72 1006, čl. 4.2.1.1","search_zh":"土 压实度测定 ČSN 72 1006, čl. 4.2.1.1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}