{"lab":{"_id":"69ad52a4de79e566650fd58e","accr_number":"1753","country":"CZ","accr_body":"ČIA","address":"Tolstého 1556/16, 586 01 Jihlava","categories":["materials"],"city":"Jihlava","imported_at":"2026-03-08T10:42:44.590Z","methods_count":8,"name":"Vysoká škola polytechnická Jihlava","parse_status":"parsed","parse_version":5,"pdf_files":["1753_429_2023_CS.pdf","1753_429_2023_EN.pdf"],"scope_summary":"Badania mechaniczne części z metali i tworzyw sztucznych przez rozciąganie i inne badania mechaniczne metalowych śrub kostnych oraz badania drgań i udarów, w zakresie określonym w załączniku do świadectwa.","search_text":"vysoká škola polytechnická jihlava tolstého 1556/16, 586 01 jihlava 1753","status":"active","updated_at":"2026-03-08T14:52:16.039Z","valid_from":"","valid_until":"10-08-2028","website":"www.vspj.cz","location":{"type":"Point","coordinates":[15.5912,49.3961]},"email_confidence":"high","email_mx":true,"email_source":"https://www.vspj.cz","map_coord":[49.398726,15.582665],"map_geo":"nominatim-street","certificate_date":"01.04.2026","certificate_no":"160/2026","certificate_replaces":"429/2023 z 10.08.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania mechaniczne części z metali i tworzyw sztucznych przez rozciąganie i inne badania mechaniczne metalowych śrub kostnych oraz badania drgań i udarów, w zakresie określonym w załączniku do świadectwa.","en":"Mechanical tensile tests of metal and plastic components and other mechanical tests of metal bone screws, and vibration and shock testing to the extent as specified in the appendix to this Certificate.","zh":"金属和塑料部件拉伸力学试验、金属骨螺钉其他力学试验以及振动和冲击试验，范围见本证书附件。","cs":"Mechanické zkoušky součástí z kovů a plastů tahem a další mechanické zkoušky kovových kostních šroubů a zkoušky vibrací a rázem, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Pomiarów Eksperymentalnych","lab_division_cs":"Laboratoř experimentálních měření","lab_division_en":"Laboratory of Experimental Measurements","lab_division_zh":"实验测量实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"ASTM","pl":"Amerykańskie Stowarzyszenie Badań i Materiałów (American Society for Testing and Materials)","en":"American Society for Testing and Materials","zh":"美国材料与试验协会（ASTM）","cs":"American Society for Testing and Materials"},{"abbr":"ČOS","pl":"Czeski standard obronny","en":"Czech Defence Standard","zh":"捷克国防标准","cs":"Český obranný standard"},{"abbr":"AECTP","pl":"Dokumenty normalizacyjne NATO (Allied Environmental Conditions and Test Publications)","en":"NATO standardized documents (Allied Environmental Conditions and Test Publications)","zh":"北约标准化文件（盟军环境条件与试验出版物，AECTP）","cs":"Standardizované dokumenty NATO (Allied Environmental Conditions and Test Publications)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"e4fb835747cba67a71d5b4246415657bd3763b57d0993178dee31f3231c4a1bf","source_pdf_url":"https://www.cai.cz/OA/pdf/160_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/160_2026_EN.pdf"},"methods":[{"_id":"48fd5c8cb99557f230e421cc","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"1","test_object":"Tworzywa sztuczne","test_object_en":"Plastics","test_object_zh":"塑料","test_object_cs":"Plasty","methodology":"Próba rozciągania","methodology_en":"Tensile test","methodology_zh":"拉伸试验","methodology_cs":"Tahová zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba rozciągania","reference":"SOP 01 (ČSN EN ISO 527-1, mimo čl. 10.4; ČSN EN ISO 527-2; ČSN EN ISO 527-3; ČSN EN ISO 527-4; ČSN EN ISO 527-5)","norm_bases":["SOP 01","ČSN EN ISO 527-1, mimo čl. 10.4","ČSN EN ISO 527-2","ČSN EN ISO 527-3","ČSN EN ISO 527-4","ČSN EN ISO 527-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tworzywa sztuczne Próba rozciągania Plasty Tahová zkouška SOP 01 (ČSN EN ISO 527-1, mimo čl. 10.4; ČSN EN ISO 527-2; ČSN EN ISO 527-3; ČSN EN ISO 527-4; ČSN EN ISO 527-5) Tworzywa sztuczne Proba rozciagania Plasty Tahova zkouska SOP 01 (CSN EN ISO 527-1, mimo cl. 10.4; CSN EN ISO 527-2; CSN EN ISO 527-3; CSN EN ISO 527-4; CSN EN ISO 527-5)","search_en":"Plastics Tensile test SOP 01 (ČSN EN ISO 527-1, mimo čl. 10.4; ČSN EN ISO 527-2; ČSN EN ISO 527-3; ČSN EN ISO 527-4; ČSN EN ISO 527-5)","search_zh":"塑料 拉伸试验 SOP 01 (ČSN EN ISO 527-1, mimo čl. 10.4; ČSN EN ISO 527-2; ČSN EN ISO 527-3; ČSN EN ISO 527-4; ČSN EN ISO 527-5)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b9d653a20908d04698bed5d","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"2","test_object":"Metale","test_object_en":"Metals","test_object_zh":"金属","test_object_cs":"Kovy","methodology":"Próba rozciągania","methodology_en":"Tensile test","methodology_zh":"拉伸试验","methodology_cs":"Tahová zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba rozciągania","reference":"SOP 02 (ČSN EN ISO 6892-1)","norm_bases":["SOP 02","ČSN EN ISO 6892-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Metale Próba rozciągania Kovy Tahová zkouška SOP 02 (ČSN EN ISO 6892-1) Metale Proba rozciagania Kovy Tahova zkouska SOP 02 (CSN EN ISO 6892-1)","search_en":"Metals Tensile test SOP 02 (ČSN EN ISO 6892-1)","search_zh":"金属 拉伸试验 SOP 02 (ČSN EN ISO 6892-1)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08b4854bfdc05f3acbe15c06","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"3","test_object":"Metalowe śruby kostne","test_object_en":"Metal bone screws","test_object_zh":"金属骨螺钉","test_object_cs":"Kovové šrouby do kosti","methodology":"Oznaczanie właściwości skrętnych","methodology_en":"Torsional properties determination","methodology_zh":"扭转性能测定","methodology_cs":"Stanovení torzních vlastností","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie właściwości skrętnych","reference":"SOP 03 (ASTM F543, čl. 10.1.1, 10.1.2)","norm_bases":["SOP 03","ASTM F543, čl. 10.1.1, 10.1.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Metalowe śruby kostne Oznaczanie właściwości skrętnych Kovové šrouby do kosti Stanovení torzních vlastností SOP 03 (ASTM F543, čl. 10.1.1, 10.1.2) Metalowe sruby kostne Oznaczanie wlasciwosci skretnych Kovove srouby do kosti Stanoveni torznich vlastnosti SOP 03 (ASTM F543, cl. 10.1.1, 10.1.2)","search_en":"Metal bone screws Torsional properties determination SOP 03 (ASTM F543, čl. 10.1.1, 10.1.2)","search_zh":"金属骨螺钉 扭转性能测定 SOP 03 (ASTM F543, čl. 10.1.1, 10.1.2)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b3281dc4d0510ede5687ebc4","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"4","test_object":"Metalowe śruby kostne","test_object_en":"Metal bone screws","test_object_zh":"金属骨螺钉","test_object_cs":"Kovové šrouby do kosti","methodology":"Oznaczanie momentu skręcającego (wkręcania/wykręcania)","methodology_en":"Torque determination","methodology_zh":"扭矩测定","methodology_cs":"Stanovení torzního momentu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie momentu skręcającego (wkręcania/wykręcania)","reference":"SOP 04 (ASTM F543, čl. 10.1.4, 10.1.5)","norm_bases":["SOP 04","ASTM F543, čl. 10.1.4, 10.1.5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Metalowe śruby kostne Oznaczanie momentu skręcającego (wkręcania/wykręcania) Kovové šrouby do kosti Stanovení torzního momentu SOP 04 (ASTM F543, čl. 10.1.4, 10.1.5) Metalowe sruby kostne Oznaczanie momentu skrecajacego (wkrecania/wykrecania) Kovove srouby do kosti Stanoveni torzniho momentu SOP 04 (ASTM F543, cl. 10.1.4, 10.1.5)","search_en":"Metal bone screws Torque determination SOP 04 (ASTM F543, čl. 10.1.4, 10.1.5)","search_zh":"金属骨螺钉 扭矩测定 SOP 04 (ASTM F543, čl. 10.1.4, 10.1.5)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"616694caac1f44a35cff0723","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"5","test_object":"Metalowe śruby kostne","test_object_en":"Metal bone screws","test_object_zh":"金属骨螺钉","test_object_cs":"Kovové šrouby do kosti","methodology":"Oznaczanie wytrzymałości na wyrwanie osiowe","methodology_en":"Axial pullout strength determination","methodology_zh":"轴向拔出强度测定","methodology_cs":"Stanovení pevnosti při vytržení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na wyrwanie osiowe","reference":"SOP 05 (ASTM F543, čl. 10.1.3)","norm_bases":["SOP 05","ASTM F543, čl. 10.1.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Metalowe śruby kostne Oznaczanie wytrzymałości na wyrwanie osiowe Kovové šrouby do kosti Stanovení pevnosti při vytržení SOP 05 (ASTM F543, čl. 10.1.3) Metalowe sruby kostne Oznaczanie wytrzymalosci na wyrwanie osiowe Kovove srouby do kosti Stanoveni pevnosti pri vytrzeni SOP 05 (ASTM F543, cl. 10.1.3)","search_en":"Metal bone screws Axial pullout strength determination SOP 05 (ASTM F543, čl. 10.1.3)","search_zh":"金属骨螺钉 轴向拔出强度测定 SOP 05 (ASTM F543, čl. 10.1.3)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1287a6d465a91dd874f48aa","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"6","test_object":"Metalowe śruby kostne","test_object_en":"Metal bone screws","test_object_zh":"金属骨螺钉","test_object_cs":"Kovové šrouby do kosti","methodology":"Oznaczanie siły osiowej przy samogwintowaniu","methodology_en":"Determination of axial force for self-tapping","methodology_zh":"自攻轴向力测定","methodology_cs":"Stanovení axiální síly pro samořez","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siły osiowej przy samogwintowaniu","reference":"SOP 06 (ASTM F543, čl. 10.1.6)","norm_bases":["SOP 06","ASTM F543, čl. 10.1.6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Metalowe śruby kostne Oznaczanie siły osiowej przy samogwintowaniu Kovové šrouby do kosti Stanovení axiální síly pro samořez SOP 06 (ASTM F543, čl. 10.1.6) Metalowe sruby kostne Oznaczanie sily osiowej przy samogwintowaniu Kovove srouby do kosti Stanoveni axialni sily pro samorez SOP 06 (ASTM F543, cl. 10.1.6)","search_en":"Metal bone screws Determination of axial force for self-tapping SOP 06 (ASTM F543, čl. 10.1.6)","search_zh":"金属骨螺钉 自攻轴向力测定 SOP 06 (ASTM F543, čl. 10.1.6)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a6c0ff03bd3a311625ac1df4","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"7","test_object":"Części i zespoły konstrukcyjne o charakterze mechanicznym, elektrotechnicznym i optoelektronicznym","test_object_en":"Mechanical, electrotechnical, and optoelectronical parts and assemblies","test_object_zh":"机械、电工和光电类结构零部件及组件","test_object_cs":"Konstrukční díly a celky strojírenského, elektrotechnického a optoelektronického charakteru","methodology":"Drgania","methodology_en":"Vibration","methodology_zh":"振动","methodology_cs":"Vibrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Drgania","reference":"SOP 07 (AECTP-400, metoda 401; ČOS 999902, metoda 401)","norm_bases":["SOP 07","AECTP-400, metoda 401","ČOS 999902, metoda 401"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części i zespoły konstrukcyjne o charakterze mechanicznym, elektrotechnicznym i optoelektronicznym Drgania Konstrukční díly a celky strojírenského, elektrotechnického a optoelektronického charakteru Vibrace SOP 07 (AECTP-400, metoda 401; ČOS 999902, metoda 401) Czesci i zespoly konstrukcyjne o charakterze mechanicznym, elektrotechnicznym i optoelektronicznym Drgania Konstrukcni dily a celky strojirenskeho, elektrotechnickeho a optoelektronickeho charakteru Vibrace SOP 07 (AECTP-400, metoda 401; COS 999902, metoda 401)","search_en":"Mechanical, electrotechnical, and optoelectronical parts and assemblies Vibration SOP 07 (AECTP-400, metoda 401; ČOS 999902, metoda 401)","search_zh":"机械、电工和光电类结构零部件及组件 振动 SOP 07 (AECTP-400, metoda 401; ČOS 999902, metoda 401)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ba84f14460719172e5138327","lab_id":"69ad52a4de79e566650fd58e","country":"CZ","accr_number":"1753","accr_body":"ČIA","row_label":"8","test_object":"Części i zespoły konstrukcyjne o charakterze mechanicznym, elektrotechnicznym i optoelektronicznym","test_object_en":"Mechanical, electrotechnical, and optoelectronical parts and assemblies","test_object_zh":"机械、电工和光电类结构零部件及组件","test_object_cs":"Konstrukční díly a celky strojírenského, elektrotechnického a optoelektronického charakteru","methodology":"Udar o przebiegu klasycznym","methodology_en":"Shock with classic waveform","methodology_zh":"经典波形冲击","methodology_cs":"Ráz s klasickým průběhem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Udar o przebiegu klasycznym","reference":"SOP 08 (AECTP-400, metoda 403; ČOS 999902, metoda 403)","norm_bases":["SOP 08","AECTP-400, metoda 403","ČOS 999902, metoda 403"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części i zespoły konstrukcyjne o charakterze mechanicznym, elektrotechnicznym i optoelektronicznym Udar o przebiegu klasycznym Konstrukční díly a celky strojírenského, elektrotechnického a optoelektronického charakteru Ráz s klasickým průběhem SOP 08 (AECTP-400, metoda 403; ČOS 999902, metoda 403) Czesci i zespoly konstrukcyjne o charakterze mechanicznym, elektrotechnicznym i optoelektronicznym Udar o przebiegu klasycznym Konstrukcni dily a celky strojirenskeho, elektrotechnickeho a optoelektronickeho charakteru Raz s klasickym prubehem SOP 08 (AECTP-400, metoda 403; COS 999902, metoda 403)","search_en":"Mechanical, electrotechnical, and optoelectronical parts and assemblies Shock with classic waveform SOP 08 (AECTP-400, metoda 403; ČOS 999902, metoda 403)","search_zh":"机械、电工和光电类结构零部件及组件 经典波形冲击 SOP 08 (AECTP-400, metoda 403; ČOS 999902, metoda 403)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}