{"lab":{"_id":"69ad52a4de79e566650fd57e","accr_number":"1742","country":"CZ","accr_body":"ČIA","address":"Markova 952, 744 01 Frenštát pod Radhoštěm","categories":["electronics"],"city":"Frenštát pod Radhoštěm","imported_at":"2026-03-08T10:42:44.590Z","methods_count":15,"name":"Innomotics, s.r.o., odštěpný závod Elektromotory Frenštát","parse_status":"parsed","parse_version":5,"pdf_files":["1742_14_2026_CS.pdf","1742_14_2026_EN.pdf"],"scope_summary":"Badania trójfazowych silników elektrycznych","search_text":"innomotics, s.r.o., odštěpný závod elektromotory frenštát markova 952, 744 01 frenštát pod radhoštěm 1742","status":"active","updated_at":"2026-03-08T14:52:15.699Z","valid_from":"","valid_until":"03-03-2027","website":"","map_coord":[49.541577,18.216348],"map_geo":"nominatim-street","certificate_date":"09.01.2026","certificate_no":"14/2026","certificate_replaces":"546/2023 z 16.10.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania trójfazowych silników elektrycznych","en":"Testing of three-phase electric motors","zh":"三相电动机检测","cs":"Zkoušení trojfázových elektrických motorů"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badań Typu","lab_division_cs":"Typová zkušebna","lab_division_en":"Type Testing Laboratory","lab_division_zh":"型式试验站","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"IEC","pl":"Międzynarodowa Komisja Elektrotechniczna (International Electrotechnical Commission)","en":"International Electrotechnical Commission","zh":"国际电工委员会","cs":"International Electrotechnical Commission"},{"abbr":"IEEE","pl":"Instytut Inżynierów Elektryków i Elektroników (Institute of Electrical and Electronics Engineers)","en":"Institute of Electrical and Electronics Engineers","zh":"电气与电子工程师协会","cs":"Institute of Electrical and Electronics Engineers"},{"abbr":"CSA","pl":"Kanadyjskie Stowarzyszenie Normalizacyjne (Canadian Standards Association)","en":"Canadian Standards Association","zh":"加拿大标准协会","cs":"Canadian Standards Association"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"13d241acd9e11c92f006913a35e5292b5b46939a837844d2066073f41c5a736e","source_pdf_url":"https://www.cai.cz/OA/pdf/14_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/14_2026_EN.pdf"},"methods":[{"_id":"e0a3bba2be54d57d38ee1855","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"1","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Pomiar rezystancji izolacji","methodology_en":"Measurement of insulation resistance","methodology_zh":"绝缘电阻测量","methodology_cs":"Měření izolačního odporu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar rezystancji izolacji","reference":"IEC 60034-27-4, čl. 6; IEEE 43, čl. 9.1, 10","norm_bases":["IEC 60034-27-4, čl. 6","IEEE 43, čl. 9.1, 10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Pomiar rezystancji izolacji Trojfázové elektrické motory Měření izolačního odporu IEC 60034-27-4, čl. 6; IEEE 43, čl. 9.1, 10 Trojfazowe silniki elektryczne Pomiar rezystancji izolacji Trojfazove elektricke motory Mereni izolacniho odporu IEC 60034-27-4, cl. 6; IEEE 43, cl. 9.1, 10","search_en":"Three-phase electric motors Measurement of insulation resistance IEC 60034-27-4, čl. 6; IEEE 43, čl. 9.1, 10","search_zh":"三相电动机 绝缘电阻测量 IEC 60034-27-4, čl. 6; IEEE 43, čl. 9.1, 10","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3bac7b861bec5f525ac671be","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"2","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Pomiar rezystancji","methodology_en":"Measurement of resistance","methodology_zh":"电阻测量","methodology_cs":"Měření odporu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar rezystancji","reference":"IEC 60034-1, čl. 8.6.2.1; IEC 60034-2-1, čl. 5.7; IEEE Std. 118; CSA C390-10, čl. 5.7.6","norm_bases":["IEC 60034-1, čl. 8.6.2.1","IEC 60034-2-1, čl. 5.7","IEEE Std. 118","CSA C390-10, čl. 5.7.6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Pomiar rezystancji Trojfázové elektrické motory Měření odporu IEC 60034-1, čl. 8.6.2.1; IEC 60034-2-1, čl. 5.7; IEEE Std. 118; CSA C390-10, čl. 5.7.6 Trojfazowe silniki elektryczne Pomiar rezystancji Trojfazove elektricke motory Mereni odporu IEC 60034-1, cl. 8.6.2.1; IEC 60034-2-1, cl. 5.7; IEEE Std. 118; CSA C390-10, cl. 5.7.6","search_en":"Three-phase electric motors Measurement of resistance IEC 60034-1, čl. 8.6.2.1; IEC 60034-2-1, čl. 5.7; IEEE Std. 118; CSA C390-10, čl. 5.7.6","search_zh":"三相电动机 电阻测量 IEC 60034-1, čl. 8.6.2.1; IEC 60034-2-1, čl. 5.7; IEEE Std. 118; CSA C390-10, čl. 5.7.6","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b088797ba4d42f0955150ff1","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"3","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Próba wytrzymałości elektrycznej napięciem probierczym","methodology_en":"Test of electrical resistance by withstand voltage","methodology_zh":"耐电压试验","methodology_cs":"Zkouška elektrické odolnosti výdržným napětím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba wytrzymałości elektrycznej napięciem probierczym","reference":"IEC 60034-1, čl. 9.2; IEEE 112, čl. 8.2; CSA C22.2 No. 100, čl. 7.4","norm_bases":["IEC 60034-1, čl. 9.2","IEEE 112, čl. 8.2","CSA C22.2 No. 100, čl. 7.4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Próba wytrzymałości elektrycznej napięciem probierczym Trojfázové elektrické motory Zkouška elektrické odolnosti výdržným napětím IEC 60034-1, čl. 9.2; IEEE 112, čl. 8.2; CSA C22.2 No. 100, čl. 7.4 Trojfazowe silniki elektryczne Proba wytrzymalosci elektrycznej napieciem probierczym Trojfazove elektricke motory Zkouska elektricke odolnosti vydrznym napetim IEC 60034-1, cl. 9.2; IEEE 112, cl. 8.2; CSA C22.2 No. 100, cl. 7.4","search_en":"Three-phase electric motors Test of electrical resistance by withstand voltage IEC 60034-1, čl. 9.2; IEEE 112, čl. 8.2; CSA C22.2 No. 100, čl. 7.4","search_zh":"三相电动机 耐电压试验 IEC 60034-1, čl. 9.2; IEEE 112, čl. 8.2; CSA C22.2 No. 100, čl. 7.4","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ede9762f9c17987debc64bee","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"4","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Próba nagrzewania","methodology_en":"Temperature-rise test","methodology_zh":"温升试验","methodology_cs":"Zkouška oteplení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba nagrzewania","reference":"IEC 60034-1, čl. 8; IEEE 112, čl. 4.4, 5.8; CSA C390-10, čl. 7.1.2","norm_bases":["IEC 60034-1, čl. 8","IEEE 112, čl. 4.4, 5.8","CSA C390-10, čl. 7.1.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Próba nagrzewania Trojfázové elektrické motory Zkouška oteplení IEC 60034-1, čl. 8; IEEE 112, čl. 4.4, 5.8; CSA C390-10, čl. 7.1.2 Trojfazowe silniki elektryczne Proba nagrzewania Trojfazove elektricke motory Zkouska otepleni IEC 60034-1, cl. 8; IEEE 112, cl. 4.4, 5.8; CSA C390-10, cl. 7.1.2","search_en":"Three-phase electric motors Temperature-rise test IEC 60034-1, čl. 8; IEEE 112, čl. 4.4, 5.8; CSA C390-10, čl. 7.1.2","search_zh":"三相电动机 温升试验 IEC 60034-1, čl. 8; IEEE 112, čl. 4.4, 5.8; CSA C390-10, čl. 7.1.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0da38b3e481e1081d33c2d7f","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"5","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Pomiar charakterystyk roboczych przy stałym napięciu","methodology_en":"Measurement of operating characteristics at constant voltage","methodology_zh":"恒压工作特性测量","methodology_cs":"Měření pracovních charakteristik při konstantním napětí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyk roboczych przy stałym napięciu","reference":"IEC 60034-2-1, čl. 6.1.3.2.3; IEEE 112, čl. 5.6; CSA C390-10, čl. 7.1.4","norm_bases":["IEC 60034-2-1, čl. 6.1.3.2.3","IEEE 112, čl. 5.6","CSA C390-10, čl. 7.1.4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Pomiar charakterystyk roboczych przy stałym napięciu Trojfázové elektrické motory Měření pracovních charakteristik při konstantním napětí IEC 60034-2-1, čl. 6.1.3.2.3; IEEE 112, čl. 5.6; CSA C390-10, čl. 7.1.4 Trojfazowe silniki elektryczne Pomiar charakterystyk roboczych przy stalym napieciu Trojfazove elektricke motory Mereni pracovnich charakteristik pri konstantnim napeti IEC 60034-2-1, cl. 6.1.3.2.3; IEEE 112, cl. 5.6; CSA C390-10, cl. 7.1.4","search_en":"Three-phase electric motors Measurement of operating characteristics at constant voltage IEC 60034-2-1, čl. 6.1.3.2.3; IEEE 112, čl. 5.6; CSA C390-10, čl. 7.1.4","search_zh":"三相电动机 恒压工作特性测量 IEC 60034-2-1, čl. 6.1.3.2.3; IEEE 112, čl. 5.6; CSA C390-10, čl. 7.1.4","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0e1ca33239a0c77bbc7db257","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"6","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Pomiar charakterystyk obciążeniowych przy stałym momencie","methodology_en":"Measurement of loading characteristics at constant torque","methodology_zh":"恒转矩负载特性测量","methodology_cs":"Měření zatěžovacích charakteristik při konstantním momentu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyk obciążeniowych przy stałym momencie","reference":"ČSN 35 0301:1987, čl. 2.11","norm_bases":["ČSN 35 0301:1987, čl. 2.11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Pomiar charakterystyk obciążeniowych przy stałym momencie Trojfázové elektrické motory Měření zatěžovacích charakteristik při konstantním momentu ČSN 35 0301:1987, čl. 2.11 Trojfazowe silniki elektryczne Pomiar charakterystyk obciazeniowych przy stalym momencie Trojfazove elektricke motory Mereni zatezovacich charakteristik pri konstantnim momentu CSN 35 0301:1987, cl. 2.11","search_en":"Three-phase electric motors Measurement of loading characteristics at constant torque ČSN 35 0301:1987, čl. 2.11","search_zh":"三相电动机 恒转矩负载特性测量 ČSN 35 0301:1987, čl. 2.11","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b8d880ae2eba8ae9136d5318","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"7","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Pomiar charakterystyki biegu jałowego i strat jałowych","methodology_en":"Measurement of no-load curve and no-load loss","methodology_zh":"空载特性和空载损耗测量","methodology_cs":"Měření charakteristiky naprázdno a ztrát naprázdno","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyki biegu jałowego i strat jałowych","reference":"IEC 60034-2-1, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE 112, čl. 5.5; CSA C390-10, čl. 7.1.6, 7.1.7","norm_bases":["IEC 60034-2-1, čl. 6.1.3.2.4, 6.1.3.2.5","IEEE 112, čl. 5.5","CSA C390-10, čl. 7.1.6, 7.1.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Pomiar charakterystyki biegu jałowego i strat jałowych Trojfázové elektrické motory Měření charakteristiky naprázdno a ztrát naprázdno IEC 60034-2-1, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE 112, čl. 5.5; CSA C390-10, čl. 7.1.6, 7.1.7 Trojfazowe silniki elektryczne Pomiar charakterystyki biegu jalowego i strat jalowych Trojfazove elektricke motory Mereni charakteristiky naprazdno a ztrat naprazdno IEC 60034-2-1, cl. 6.1.3.2.4, 6.1.3.2.5; IEEE 112, cl. 5.5; CSA C390-10, cl. 7.1.6, 7.1.7","search_en":"Three-phase electric motors Measurement of no-load curve and no-load loss IEC 60034-2-1, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE 112, čl. 5.5; CSA C390-10, čl. 7.1.6, 7.1.7","search_zh":"三相电动机 空载特性和空载损耗测量 IEC 60034-2-1, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE 112, čl. 5.5; CSA C390-10, čl. 7.1.6, 7.1.7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"724a183886a27f6f2a2fc904","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"8","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Wyznaczanie sprawności — pomiar bezpośredni","methodology_en":"Determination of efficiency – direct measurement","methodology_zh":"效率测定——直接测量","methodology_cs":"Určení účinnosti – přímé měření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie sprawności — pomiar bezpośredni","reference":"IEC 60034-2-1, čl. 6.1, Metoda 2-1-1A; IEEE 112, Test Method A","norm_bases":["IEC 60034-2-1, čl. 6.1, Metoda 2-1-1A","IEEE 112, Test Method A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Wyznaczanie sprawności — pomiar bezpośredni Trojfázové elektrické motory Určení účinnosti – přímé měření IEC 60034-2-1, čl. 6.1, Metoda 2-1-1A; IEEE 112, Test Method A Trojfazowe silniki elektryczne Wyznaczanie sprawnosci — pomiar bezposredni Trojfazove elektricke motory Urceni ucinnosti – prime mereni IEC 60034-2-1, cl. 6.1, Metoda 2-1-1A; IEEE 112, Test Method A","search_en":"Three-phase electric motors Determination of efficiency – direct measurement IEC 60034-2-1, čl. 6.1, Metoda 2-1-1A; IEEE 112, Test Method A","search_zh":"三相电动机 效率测定——直接测量 IEC 60034-2-1, čl. 6.1, Metoda 2-1-1A; IEEE 112, Test Method A","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a69fe9ca4b20b7311afbeff7","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"9","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Wyznaczanie sprawności — na podstawie strat dodatkowych","methodology_en":"Determination of efficiency – determination on the basis of residual losses","methodology_zh":"效率测定——基于剩余损耗","methodology_cs":"Určení účinnosti – stanovení ze zbytkových ztrát","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie sprawności — na podstawie strat dodatkowych","reference":"IEC 60034-2-1, Metoda 2-1-1B; IEEE 112, Test Method B; CSA C390-10, čl. 7.2","norm_bases":["IEC 60034-2-1, Metoda 2-1-1B","IEEE 112, Test Method B","CSA C390-10, čl. 7.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Wyznaczanie sprawności — na podstawie strat dodatkowych Trojfázové elektrické motory Určení účinnosti – stanovení ze zbytkových ztrát IEC 60034-2-1, Metoda 2-1-1B; IEEE 112, Test Method B; CSA C390-10, čl. 7.2 Trojfazowe silniki elektryczne Wyznaczanie sprawnosci — na podstawie strat dodatkowych Trojfazove elektricke motory Urceni ucinnosti – stanoveni ze zbytkovych ztrat IEC 60034-2-1, Metoda 2-1-1B; IEEE 112, Test Method B; CSA C390-10, cl. 7.2","search_en":"Three-phase electric motors Determination of efficiency – determination on the basis of residual losses IEC 60034-2-1, Metoda 2-1-1B; IEEE 112, Test Method B; CSA C390-10, čl. 7.2","search_zh":"三相电动机 效率测定——基于剩余损耗 IEC 60034-2-1, Metoda 2-1-1B; IEEE 112, Test Method B; CSA C390-10, čl. 7.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"480acdde2a594a5b39afbf74","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"10","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Pomiar charakterystyki zwarcia i strat zwarciowych","methodology_en":"Measurement of short-circuit curve and short-circuit loss","methodology_zh":"短路特性和短路损耗测量","methodology_cs":"Měření charakteristiky nakrátko a ztrát nakrátko","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyki zwarcia i strat zwarciowych","reference":"IEEE 112, čl. 7.2","norm_bases":["IEEE 112, čl. 7.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Pomiar charakterystyki zwarcia i strat zwarciowych Trojfázové elektrické motory Měření charakteristiky nakrátko a ztrát nakrátko IEEE 112, čl. 7.2 Trojfazowe silniki elektryczne Pomiar charakterystyki zwarcia i strat zwarciowych Trojfazove elektricke motory Mereni charakteristiky nakratko a ztrat nakratko IEEE 112, cl. 7.2","search_en":"Three-phase electric motors Measurement of short-circuit curve and short-circuit loss IEEE 112, čl. 7.2","search_zh":"三相电动机 短路特性和短路损耗测量 IEEE 112, čl. 7.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5831384a126a2d6f1c64296e","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"11","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Pomiar charakterystyki momentu","methodology_en":"Measurement of torque curve","methodology_zh":"转矩特性测量","methodology_cs":"Měření momentové charakteristiky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyki momentu","reference":"IEEE 112, čl. 7.3.2.5","norm_bases":["IEEE 112, čl. 7.3.2.5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Pomiar charakterystyki momentu Trojfázové elektrické motory Měření momentové charakteristiky IEEE 112, čl. 7.3.2.5 Trojfazowe silniki elektryczne Pomiar charakterystyki momentu Trojfazove elektricke motory Mereni momentove charakteristiky IEEE 112, cl. 7.3.2.5","search_en":"Three-phase electric motors Measurement of torque curve IEEE 112, čl. 7.3.2.5","search_zh":"三相电动机 转矩特性测量 IEEE 112, čl. 7.3.2.5","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"987ce11f557c42854282f67a","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"12","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Próba przeciążalności prądowej","methodology_en":"Current overload ability test","methodology_zh":"过电流能力试验","methodology_cs":"Zkouška proudové přetížitelnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przeciążalności prądowej","reference":"IEC 60034-1, čl. 9.3","norm_bases":["IEC 60034-1, čl. 9.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Próba przeciążalności prądowej Trojfázové elektrické motory Zkouška proudové přetížitelnosti IEC 60034-1, čl. 9.3 Trojfazowe silniki elektryczne Proba przeciazalnosci pradowej Trojfazove elektricke motory Zkouska proudove pretizitelnosti IEC 60034-1, cl. 9.3","search_en":"Three-phase electric motors Current overload ability test IEC 60034-1, čl. 9.3","search_zh":"三相电动机 过电流能力试验 IEC 60034-1, čl. 9.3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"34e3783606128e457fa0e013","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"13","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Próba przeciążalności momentem","methodology_en":"Torque overload ability test","methodology_zh":"过转矩能力试验","methodology_cs":"Zkouška momentové přetížitelnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przeciążalności momentem","reference":"IEC 60034-1, čl. 9.4","norm_bases":["IEC 60034-1, čl. 9.4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Próba przeciążalności momentem Trojfázové elektrické motory Zkouška momentové přetížitelnosti IEC 60034-1, čl. 9.4 Trojfazowe silniki elektryczne Proba przeciazalnosci momentem Trojfazove elektricke motory Zkouska momentove pretizitelnosti IEC 60034-1, cl. 9.4","search_en":"Three-phase electric motors Torque overload ability test IEC 60034-1, čl. 9.4","search_zh":"三相电动机 过转矩能力试验 IEC 60034-1, čl. 9.4","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c74dc930fd4abbbe396102af","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"14","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Próba wytrzymałości mechanicznej (próba podwyższonej prędkości obrotowej)","methodology_en":"Mechanical resistance test (test at elevated speed)","methodology_zh":"机械强度试验（超速试验）","methodology_cs":"Zkouška mechanické odolnosti (zkouška zvýšenými otáčkami)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba wytrzymałości mechanicznej (próba podwyższonej prędkości obrotowej)","reference":"IEC 60034-1, čl. 9.6, 9.7","norm_bases":["IEC 60034-1, čl. 9.6, 9.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Próba wytrzymałości mechanicznej (próba podwyższonej prędkości obrotowej) Trojfázové elektrické motory Zkouška mechanické odolnosti (zkouška zvýšenými otáčkami) IEC 60034-1, čl. 9.6, 9.7 Trojfazowe silniki elektryczne Proba wytrzymalosci mechanicznej (proba podwyzszonej predkosci obrotowej) Trojfazove elektricke motory Zkouska mechanicke odolnosti (zkouska zvysenymi otackami) IEC 60034-1, cl. 9.6, 9.7","search_en":"Three-phase electric motors Mechanical resistance test (test at elevated speed) IEC 60034-1, čl. 9.6, 9.7","search_zh":"三相电动机 机械强度试验（超速试验） IEC 60034-1, čl. 9.6, 9.7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9fe0eb98c7fecf028cb12bb5","lab_id":"69ad52a4de79e566650fd57e","country":"CZ","accr_number":"1742","accr_body":"ČIA","row_label":"15","test_object":"Trójfazowe silniki elektryczne","test_object_en":"Three-phase electric motors","test_object_zh":"三相电动机","test_object_cs":"Trojfázové elektrické motory","methodology":"Sprawdzenie zabezpieczenia termistorowego","methodology_en":"Thermistor protection assessment","methodology_zh":"热敏电阻保护检查","methodology_cs":"Prověření termistorové ochrany","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Sprawdzenie zabezpieczenia termistorowego","reference":"IEC 60034-11, čl. 8.2","norm_bases":["IEC 60034-11, čl. 8.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Trójfazowe silniki elektryczne Sprawdzenie zabezpieczenia termistorowego Trojfázové elektrické motory Prověření termistorové ochrany IEC 60034-11, čl. 8.2 Trojfazowe silniki elektryczne Sprawdzenie zabezpieczenia termistorowego Trojfazove elektricke motory Provereni termistorove ochrany IEC 60034-11, cl. 8.2","search_en":"Three-phase electric motors Thermistor protection assessment IEC 60034-11, čl. 8.2","search_zh":"三相电动机 热敏电阻保护检查 IEC 60034-11, čl. 8.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}