{"lab":{"_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","categories":["construction"],"city":"Ústí nad Labem","imported_at":"2026-03-08T10:42:44.590Z","methods_count":9,"name":"AZ Consult, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1740_109_2022_CS.pdf","1740_109_2022_EN.pdf"],"scope_summary":"Badania klasyfikacyjne gruntów, badania polowe na drogach, pomiary i monitoring deformacji powierzchni terenu i obiektów budowlanych.","search_text":"az consult, spol. s r.o. klíšská 1334/12, ústí nad labem-centrum, 400 01 ústí nad labem 1740","status":"active","updated_at":"2026-03-08T14:52:15.698Z","valid_from":"","valid_until":"01-03-2027","website":"www.azconsult.cz","location":{"type":"Point","coordinates":[14.0323,50.6607]},"map_coord":[50.662335,14.032196],"map_geo":"nominatim-street","certificate_date":"01.03.2022","certificate_no":"109/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania klasyfikacyjne gruntów, badania polowe na drogach, pomiary i monitoring deformacji powierzchni terenu i obiektów budowlanych.","en":"Classification analyses of soils, field tests on roads, measurement and monitoring of deformations of the ground surface and building structures.","zh":"土的分类分析、道路现场试验、地表和建筑物变形的测量与监测。","cs":"Klasifikační rozbory zemin, polní zkoušky na pozemních komunikacích, měření a monitoring deformací povrchu terénu a stavebních objektů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium AZ Consult","lab_division_cs":"Laboratoř AZ Consult","lab_division_en":"AZ Consult Laboratory","lab_division_zh":"AZ Consult 实验室","lab_locations":[{"code":null,"name":"AZ Consult, spol. s r.o.","street":"Klíšská 1334/12, Ústí nad Labem-centrum","postal_code":"400 01","city":"Ústí nad Labem","is_hq":true,"address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","site":"40001|klíšská1334/12ústínadlabem-centrum"},{"code":null,"name":"Laboratorium Mechaniki Gruntów i Badań Polowych","street":"Klíšská 1334/12, Ústí nad Labem-centrum","postal_code":"400 01","city":"Ústí nad Labem","is_hq":false,"address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","site":"40001|klíšská1334/12ústínadlabem-centrum"},{"code":null,"name":"Laboratorium Monitoringu i Pomiarów","street":"Obchodní 3","postal_code":"434 01","city":"Most-Velebudice","is_hq":false,"address":"Obchodní 3, 434 01 Most-Velebudice","site":"43401|obchodní3"}],"lab_locations_en":[{"code":null,"name":"AZ Consult, spol. s r.o.","street":"Klíšská 1334/12, Ústí nad Labem-centrum","postal_code":"400 01","city":"Ústí nad Labem","is_hq":true,"address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","site":"40001|klíšská1334/12ústínadlabem-centrum"},{"code":null,"name":"Soil Mechanics and Field Testing Laboratory","street":"Klíšská 1334/12, Ústí nad Labem-centrum","postal_code":"400 01","city":"Ústí nad Labem","is_hq":false,"address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","site":"40001|klíšská1334/12ústínadlabem-centrum"},{"code":null,"name":"Monitoring and Measurement Laboratory","street":"Obchodní 3","postal_code":"434 01","city":"Most-Velebudice","is_hq":false,"address":"Obchodní 3, 434 01 Most-Velebudice","site":"43401|obchodní3"}],"lab_locations_zh":[{"code":null,"name":"AZ Consult, spol. s r.o.","street":"Klíšská 1334/12, Ústí nad Labem-centrum","postal_code":"400 01","city":"Ústí nad Labem","is_hq":true,"address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","site":"40001|klíšská1334/12ústínadlabem-centrum"},{"code":null,"name":"土力学与现场试验实验室","street":"Klíšská 1334/12, Ústí nad Labem-centrum","postal_code":"400 01","city":"Ústí nad Labem","is_hq":false,"address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","site":"40001|klíšská1334/12ústínadlabem-centrum"},{"code":null,"name":"监测与测量实验室","street":"Obchodní 3","postal_code":"434 01","city":"Most-Velebudice","is_hq":false,"address":"Obchodní 3, 434 01 Most-Velebudice","site":"43401|obchodní3"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie fachowe i interpretacje wyników badań.","en":"The laboratory provides expert opinions and interpretations of test results.","zh":"实验室提供检测结果的专业意见和解释。","cs":"Laboratoř poskytuje odborná stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"42dbc038abb0a137661531f2024e81710dd85670f6d9a577062e1d265847071f","source_pdf_url":"https://www.cai.cz/OA/pdf/P109_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"01a3d7919bc48a3423ed9324","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"1","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率的测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN ISO 17892-1","norm_bases":["ČSN EN ISO 17892-1"],"lab_section":"Laboratorium Mechaniki Gruntów i Badań Polowych","lab_section_en":"Soil Mechanics and Field Testing Laboratory","lab_section_zh":"土力学与现场试验实验室","lab_section_cs":"Laboratoř mechaniky zemin a polních zkoušek","lab_address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wilgotności Zeminy Stanovení vlhkosti ČSN EN ISO 17892-1 Grunty Oznaczanie wilgotnosci Zeminy Stanoveni vlhkosti CSN EN ISO 17892-1","search_en":"Soils Determination of water content ČSN EN ISO 17892-1","search_zh":"土 含水率的测定 ČSN EN ISO 17892-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8547097596580900ffcedffe","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"2","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配的测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN ISO 17892-4","norm_bases":["ČSN EN ISO 17892-4"],"lab_section":"Laboratorium Mechaniki Gruntów i Badań Polowych","lab_section_en":"Soil Mechanics and Field Testing Laboratory","lab_section_zh":"土力学与现场试验实验室","lab_section_cs":"Laboratoř mechaniky zemin a polních zkoušek","lab_address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie uziarnienia Zeminy Stanovení zrnitosti ČSN EN ISO 17892-4 Grunty Oznaczanie uziarnienia Zeminy Stanoveni zrnitosti CSN EN ISO 17892-4","search_en":"Soils Determination of particle size distribution ČSN EN ISO 17892-4","search_zh":"土 颗粒级配的测定 ČSN EN ISO 17892-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a76167f90acb224b94d8d52","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"3","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie granic konsystencji","methodology_en":"Determination of consistency limits","methodology_zh":"稠度界限的测定","methodology_cs":"Stanovení konzistenčních mezí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie granic konsystencji","reference":"ČSN EN ISO 17892-12 mimo čl. 4.3 a 5.4","norm_bases":["ČSN EN ISO 17892-12"],"lab_section":"Laboratorium Mechaniki Gruntów i Badań Polowych","lab_section_en":"Soil Mechanics and Field Testing Laboratory","lab_section_zh":"土力学与现场试验实验室","lab_section_cs":"Laboratoř mechaniky zemin a polních zkoušek","lab_address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie granic konsystencji Zeminy Stanovení konzistenčních mezí ČSN EN ISO 17892-12 mimo čl. 4.3 a 5.4 Grunty Oznaczanie granic konsystencji Zeminy Stanoveni konzistencnich mezi CSN EN ISO 17892-12 mimo cl. 4.3 a 5.4","search_en":"Soils Determination of consistency limits ČSN EN ISO 17892-12 mimo čl. 4.3 a 5.4","search_zh":"土 稠度界限的测定 ČSN EN ISO 17892-12 mimo čl. 4.3 a 5.4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"46211b456435131b3602f737","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"4","test_object":"Warstwy konstrukcyjne i materiały sypkie (nasypy)","test_object_en":"Structural layers and fills","test_object_zh":"结构层和填料","test_object_cs":"Konstrukční vrstvy a sypaniny","methodology":"Statyczna próba obciążeniowa (płytą)","methodology_en":"Static plate load test","methodology_zh":"静载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Statyczna próba obciążeniowa (płytą)","reference":"ČSN 72 1006, příloha A, B, D","norm_bases":["ČSN 72 1006"],"lab_section":"Laboratorium Mechaniki Gruntów i Badań Polowych","lab_section_en":"Soil Mechanics and Field Testing Laboratory","lab_section_zh":"土力学与现场试验实验室","lab_section_cs":"Laboratoř mechaniky zemin a polních zkoušek","lab_address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwy konstrukcyjne i materiały sypkie (nasypy) Statyczna próba obciążeniowa (płytą) Konstrukční vrstvy a sypaniny Statická zatěžovací zkouška ČSN 72 1006, příloha A, B, D Warstwy konstrukcyjne i materialy sypkie (nasypy) Statyczna proba obciazeniowa (plyta) Konstrukcni vrstvy a sypaniny Staticka zatezovaci zkouska CSN 72 1006, priloha A, B, D","search_en":"Structural layers and fills Static plate load test ČSN 72 1006, příloha A, B, D","search_zh":"结构层和填料 静载试验 ČSN 72 1006, příloha A, B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"712c42bf0ab538d3af52a780","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"5","test_object":"Warstwy konstrukcyjne i materiały sypkie (nasypy)","test_object_en":"Structural layers and fills","test_object_zh":"结构层和填料","test_object_cs":"Konstrukční vrstvy a sypaniny","methodology":"Dynamiczna próba obciążeniowa","methodology_en":"Impact load test","methodology_zh":"冲击荷载试验","methodology_cs":"Rázová zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Lekka płyta dynamiczna","technique_en":"Light dynamic plate","technique_zh":"轻型动力板","technique_cs":"lehkou dynamickou deskou","techniques":["Lekka płyta dynamiczna"],"techniques_en":["Light dynamic plate"],"techniques_zh":["轻型动力板"],"techniques_cs":["lehkou dynamickou deskou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Dynamiczna próba obciążeniowa\nLekka płyta dynamiczna","reference":"ČSN 73 6192, skupina C","norm_bases":["ČSN 73 6192"],"lab_section":"Laboratorium Mechaniki Gruntów i Badań Polowych","lab_section_en":"Soil Mechanics and Field Testing Laboratory","lab_section_zh":"土力学与现场试验实验室","lab_section_cs":"Laboratoř mechaniky zemin a polních zkoušek","lab_address":"Klíšská 1334/12, Ústí nad Labem-centrum, 400 01 Ústí nad Labem","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwy konstrukcyjne i materiały sypkie (nasypy) Dynamiczna próba obciążeniowa Lekka płyta dynamiczna Konstrukční vrstvy a sypaniny Rázová zatěžovací zkouška lehkou dynamickou deskou ČSN 73 6192, skupina C Warstwy konstrukcyjne i materialy sypkie (nasypy) Dynamiczna proba obciazeniowa Lekka plyta dynamiczna Konstrukcni vrstvy a sypaniny Razova zatezovaci zkouska lehkou dynamickou deskou CSN 73 6192, skupina C","search_en":"Structural layers and fills Impact load test Light dynamic plate ČSN 73 6192, skupina C","search_zh":"结构层和填料 冲击荷载试验 轻型动力板 ČSN 73 6192, skupina C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5c9fd71fc0572027f7915f2d","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"1","test_object":"Obiekty budowlane","test_object_en":"Building structures","test_object_zh":"建筑物","test_object_cs":"Stavební objekty","methodology":"Pomiary geodezyjne przemieszczeń i odkształceń pionowych, poziomych i przestrzennych","methodology_en":"Geodetic measurement of vertical, horizontal and spatial displacements and deformations","methodology_zh":"垂直、水平和空间位移及变形的大地测量","methodology_cs":"Geodetická měření svislých, vodorovných a prostorových posunů a deformací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiary geodezyjne przemieszczeń i odkształceń pionowych, poziomych i przestrzennych","reference":"PP11 (ČSN EN ISO 18674-2), PP12, PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2)","norm_bases":["PP11","ČSN EN ISO 18674-2","PP12","PP13","ČSN 73 0415","ČSN ISO 4463-1","ČSN 73 0420-2"],"lab_section":"Laboratorium Monitoringu i Pomiarów","lab_section_en":"Monitoring and Measurement Laboratory","lab_section_zh":"监测与测量实验室","lab_section_cs":"Laboratoř monitoringu a měření","lab_address":"Obchodní 3, 434 01 Most-Velebudice","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obiekty budowlane Pomiary geodezyjne przemieszczeń i odkształceń pionowych, poziomych i przestrzennych Stavební objekty Geodetická měření svislých, vodorovných a prostorových posunů a deformací PP11 (ČSN EN ISO 18674-2), PP12, PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2) Obiekty budowlane Pomiary geodezyjne przemieszczen i odksztalcen pionowych, poziomych i przestrzennych Stavebni objekty Geodeticka mereni svislych, vodorovnych a prostorovych posunu a deformaci PP11 (CSN EN ISO 18674-2), PP12, PP13 (CSN 73 0415, CSN ISO 4463-1, CSN 73 0420-2)","search_en":"Building structures Geodetic measurement of vertical, horizontal and spatial displacements and deformations PP11 (ČSN EN ISO 18674-2), PP12, PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2)","search_zh":"建筑物 垂直、水平和空间位移及变形的大地测量 PP11 (ČSN EN ISO 18674-2), PP12, PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"607db67ad8197589a0d46555","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"2","test_object":"Obiekty budowlane","test_object_en":"Building structures","test_object_zh":"建筑物","test_object_cs":"Stavební objekty","methodology":"Pomiary deformometryczne","methodology_en":"Deformometric measurement","methodology_zh":"变形计测量","methodology_cs":"Deformometrická měření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiary deformometryczne","reference":"PP10 (návod výrobce GLÖTZL P 084.20 Hydrostatische Setzung HPG)","norm_bases":["PP10","návod výrobce GLÖTZL P 084.20 Hydrostatische Setzung HPG"],"lab_section":"Laboratorium Monitoringu i Pomiarów","lab_section_en":"Monitoring and Measurement Laboratory","lab_section_zh":"监测与测量实验室","lab_section_cs":"Laboratoř monitoringu a měření","lab_address":"Obchodní 3, 434 01 Most-Velebudice","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obiekty budowlane Pomiary deformometryczne Stavební objekty Deformometrická měření PP10 (návod výrobce GLÖTZL P 084.20 Hydrostatische Setzung HPG) Obiekty budowlane Pomiary deformometryczne Stavebni objekty Deformometricka mereni PP10 (navod vyrobce GLOTZL P 084.20 Hydrostatische Setzung HPG)","search_en":"Building structures Deformometric measurement PP10 (návod výrobce GLÖTZL P 084.20 Hydrostatische Setzung HPG)","search_zh":"建筑物 变形计测量 PP10 (návod výrobce GLÖTZL P 084.20 Hydrostatische Setzung HPG)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1cdb96b9da2810b2e37dfe8","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"3","test_object":"Obiekty budowlane","test_object_en":"Building structures","test_object_zh":"建筑物","test_object_cs":"Stavební objekty","methodology":"Pomiary konwergencji","methodology_en":"Convergence measurement","methodology_zh":"收敛测量","methodology_cs":"Konvergenční měření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiary konwergencji","reference":"PP11 (ČSN EN ISO 18674-2), PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2)","norm_bases":["PP11","ČSN EN ISO 18674-2","PP13","ČSN 73 0415","ČSN ISO 4463-1","ČSN 73 0420-2"],"lab_section":"Laboratorium Monitoringu i Pomiarów","lab_section_en":"Monitoring and Measurement Laboratory","lab_section_zh":"监测与测量实验室","lab_section_cs":"Laboratoř monitoringu a měření","lab_address":"Obchodní 3, 434 01 Most-Velebudice","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obiekty budowlane Pomiary konwergencji Stavební objekty Konvergenční měření PP11 (ČSN EN ISO 18674-2), PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2) Obiekty budowlane Pomiary konwergencji Stavebni objekty Konvergencni mereni PP11 (CSN EN ISO 18674-2), PP13 (CSN 73 0415, CSN ISO 4463-1, CSN 73 0420-2)","search_en":"Building structures Convergence measurement PP11 (ČSN EN ISO 18674-2), PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2)","search_zh":"建筑物 收敛测量 PP11 (ČSN EN ISO 18674-2), PP13 (ČSN 73 0415, ČSN ISO 4463-1, ČSN 73 0420-2)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d3a8873be4f42fc74619227d","lab_id":"69ad52a4de79e566650fd57c","country":"CZ","accr_number":"1740","accr_body":"ČIA","row_label":"4","test_object":"Otwory (kolumny) inklinometryczne","test_object_en":"Inclinometer casings","test_object_zh":"测斜管","test_object_cs":"Inklinometrické stvoly","methodology":"Pomiary inklinometryczne","methodology_en":"Inclinometric measurement","methodology_zh":"测斜测量","methodology_cs":"Inklinometrická měření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiary inklinometryczne","reference":"PP06 (ČSN EN ISO 18674-3)","norm_bases":["PP06","ČSN EN ISO 18674-3"],"lab_section":"Laboratorium Monitoringu i Pomiarów","lab_section_en":"Monitoring and Measurement Laboratory","lab_section_zh":"监测与测量实验室","lab_section_cs":"Laboratoř monitoringu a měření","lab_address":"Obchodní 3, 434 01 Most-Velebudice","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Otwory (kolumny) inklinometryczne Pomiary inklinometryczne Inklinometrické stvoly Inklinometrická měření PP06 (ČSN EN ISO 18674-3) Otwory (kolumny) inklinometryczne Pomiary inklinometryczne Inklinometricke stvoly Inklinometricka mereni PP06 (CSN EN ISO 18674-3)","search_en":"Inclinometer casings Inclinometric measurement PP06 (ČSN EN ISO 18674-3)","search_zh":"测斜管 测斜测量 PP06 (ČSN EN ISO 18674-3)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}