{"lab":{"_id":"69ad52a4de79e566650fd572","accr_number":"1733","country":"CZ","accr_body":"ČIA","address":"Počáteční 1879/19, 710 00 Ostrava - Slezská Ostrava","categories":["water","environment"],"city":"Ostrava - Slezská Ostrava","imported_at":"2026-03-08T10:42:44.590Z","methods_count":11,"name":"ORGREZ, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1733_659_2024_CS.pdf","1733_659_2024_EN.pdf"],"scope_summary":"Pobieranie próbek, analizy fizykochemiczne wód, wyciągów wodnych, roztworów absorpcyjnych i materiałów stałych.","search_text":"orgrez, a.s. počáteční 1879/19, 710 00 ostrava - slezská ostrava 1733","status":"active","updated_at":"2026-03-08T14:52:15.621Z","valid_from":"","valid_until":"30-11-2026","website":"www.orgrez.cz","location":{"type":"Point","coordinates":[18.2625,49.8209]},"email_confidence":"high","email_mx":true,"email_source":"https://www.orgrez.cz","map_coord":[49.823236,18.318261],"map_geo":"nominatim-street","certificate_date":"05.12.2024","certificate_no":"659/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek, analizy fizykochemiczne wód, wyciągów wodnych, roztworów absorpcyjnych i materiałów stałych.","en":"Sampling, physico-chemical analysis of water, aqueous extracts, absorption solutions and solid materials.","zh":"采样，水、水浸出液、吸收液和固体材料的理化分析。","cs":"Odběr vzorků, fyzikálně-chemické analýzy vod, vodních výluhů, absorpčních roztoků a pevných materiálů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze Ostrawa","lab_division_cs":"Zkušební laboratoř Ostrava","lab_division_en":"Testing Laboratory Ostrava","lab_division_zh":"俄斯特拉发检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard Operating Procedure","zh":"标准操作程序","cs":"standardní operační postup"},{"abbr":"ICP-MS","pl":"Spektrometria mas z plazmą wzbudzoną indukcyjnie","en":"Inductively Coupled Plasma Mass Spectrometry","zh":"电感耦合等离子体质谱法","cs":"hmotnostní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"AMA 254","pl":"Jednofunkcyjny atomowy spektrometr absorpcyjny","en":"single purpose atomic absorption spectrometer","zh":"专用原子吸收光谱仪","cs":"jednoúčelový atomový absorpční spektrometr"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立开展采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."},{"pl":"Szczegółowe informacje o działalności w zakresie akredytacji (oznaczane anality, literatura źródłowa, przedmiot badań) podano w części „Upřesnění rozsahu akreditace” (doprecyzowanie zakresu akredytacji).","en":"Detailed information on activities within the scope of accreditation (determined analytes, source literature, tested subject) is given in the section „Specification of the scope of accreditation“","zh":"认可范围内活动的详细信息（测定的分析物、来源文献、检测对象）见“认可范围细化”部分。","cs":"Detailní informace k činnostem v rozsahu akreditace (stanovované analyty, zdrojová literatura, předmět zkoušení) jsou uvedeny v části „Upřesnění rozsahu akreditace“."}],"source_lang":"cs","source_pdf_sha256":"75043821c2e3359da4762c98d144a6770dd3bbb907c4300fc5444e2076e04729","source_pdf_url":"https://www.cai.cz/OA/pdf/P659_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P659_2024_EN.pdf"},"methods":[{"_id":"e8771515d11fd52d66473bbb","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"1","test_object":"Roztwór absorpcyjny","test_object_en":"Absorption solution","test_object_zh":"吸收液","test_object_cs":"Absorpční roztok","methodology":"Oznaczanie siarczanów metodą chromatografii jonowej z detekcją konduktometryczną","methodology_en":"Determination of sulphates by ion chromatography with conductivity detection","methodology_zh":"离子色谱-电导检测法测定硫酸盐","methodology_cs":"Stanovení síranů iontovou chromatografií s vodivostní detekcí","parameters":[{"name":"Siarczanów","range":""}],"parameters_en":[{"name":"Sulphates","range":""}],"parameters_zh":[{"name":"硫酸盐","range":""}],"parameters_cs":[{"name":"síranů","range":""}],"technique":"Chromatografia jonowa z detekcją konduktometryczną","technique_en":"Ion chromatography with conductivity detection","technique_zh":"离子色谱-电导检测法","technique_cs":"iontovou chromatografií s vodivostní detekcí","techniques":["Chromatografia jonowa z detekcją konduktometryczną"],"techniques_en":["Ion chromatography with conductivity detection"],"techniques_zh":["离子色谱-电导检测法"],"techniques_cs":["iontovou chromatografií s vodivostní detekcí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczanów metodą chromatografii jonowej z detekcją konduktometryczną\nSiarczanów\nChromatografia jonowa z detekcją konduktometryczną","reference":"SOP 01/514 (ČSN EN 14791)","norm_bases":["SOP 01/514","ČSN EN 14791"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Roztwór absorpcyjny Oznaczanie siarczanów metodą chromatografii jonowej z detekcją konduktometryczną Chromatografia jonowa z detekcją konduktometryczną Siarczanów  Absorpční roztok Stanovení síranů iontovou chromatografií s vodivostní detekcí iontovou chromatografií s vodivostní detekcí síranů  SOP 01/514 (ČSN EN 14791) Roztwor absorpcyjny Oznaczanie siarczanow metoda chromatografii jonowej z detekcja konduktometryczna Chromatografia jonowa z detekcja konduktometryczna Siarczanow  Absorpcni roztok Stanoveni siranu iontovou chromatografii s vodivostni detekci iontovou chromatografii s vodivostni detekci siranu  SOP 01/514 (CSN EN 14791)","search_en":"Absorption solution Determination of sulphates by ion chromatography with conductivity detection Ion chromatography with conductivity detection Sulphates  SOP 01/514 (ČSN EN 14791)","search_zh":"吸收液 离子色谱-电导检测法测定硫酸盐 离子色谱-电导检测法 硫酸盐  SOP 01/514 (ČSN EN 14791)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50532e6b48ba1da407149bf7","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"2","test_object":"Roztwór absorpcyjny","test_object_en":"Absorption solution","test_object_zh":"吸收液","test_object_cs":"Absorpční roztok","methodology":"Oznaczanie chlorków metodą chromatografii jonowej z detekcją konduktometryczną","methodology_en":"Determination of chlorides by ion chromatography with conductivity detection","methodology_zh":"离子色谱-电导检测法测定氯化物","methodology_cs":"Stanovení chloridů iontovou chromatografií s vodivostní detekcí","parameters":[{"name":"Chlorków","range":""}],"parameters_en":[{"name":"Chlorides","range":""}],"parameters_zh":[{"name":"氯化物","range":""}],"parameters_cs":[{"name":"chloridů","range":""}],"technique":"Chromatografia jonowa z detekcją konduktometryczną","technique_en":"Ion chromatography with conductivity detection","technique_zh":"离子色谱-电导检测法","technique_cs":"iontovou chromatografií s vodivostní detekcí","techniques":["Chromatografia jonowa z detekcją konduktometryczną"],"techniques_en":["Ion chromatography with conductivity detection"],"techniques_zh":["离子色谱-电导检测法"],"techniques_cs":["iontovou chromatografií s vodivostní detekcí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą chromatografii jonowej z detekcją konduktometryczną\nChlorków\nChromatografia jonowa z detekcją konduktometryczną","reference":"SOP 03/514 (ČSN EN 1911; ČSN EN ISO 10304-1)","norm_bases":["SOP 03/514","ČSN EN 1911","ČSN EN ISO 10304-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Roztwór absorpcyjny Oznaczanie chlorków metodą chromatografii jonowej z detekcją konduktometryczną Chromatografia jonowa z detekcją konduktometryczną Chlorków  Absorpční roztok Stanovení chloridů iontovou chromatografií s vodivostní detekcí iontovou chromatografií s vodivostní detekcí chloridů  SOP 03/514 (ČSN EN 1911; ČSN EN ISO 10304-1) Roztwor absorpcyjny Oznaczanie chlorkow metoda chromatografii jonowej z detekcja konduktometryczna Chromatografia jonowa z detekcja konduktometryczna Chlorkow  Absorpcni roztok Stanoveni chloridu iontovou chromatografii s vodivostni detekci iontovou chromatografii s vodivostni detekci chloridu  SOP 03/514 (CSN EN 1911; CSN EN ISO 10304-1)","search_en":"Absorption solution Determination of chlorides by ion chromatography with conductivity detection Ion chromatography with conductivity detection Chlorides  SOP 03/514 (ČSN EN 1911; ČSN EN ISO 10304-1)","search_zh":"吸收液 离子色谱-电导检测法测定氯化物 离子色谱-电导检测法 氯化物  SOP 03/514 (ČSN EN 1911; ČSN EN ISO 10304-1)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"63ba32ac61a92cac7e071514","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"3","test_object":"Roztwór absorpcyjny","test_object_en":"Absorption solution","test_object_zh":"吸收液","test_object_cs":"Absorpční roztok","methodology":"Oznaczanie fluorków metodą chromatografii jonowej z detekcją konduktometryczną","methodology_en":"Determination of fluorides by ion chromatography with conductivity detection","methodology_zh":"离子色谱-电导检测法测定氟化物","methodology_cs":"Stanovení fluoridů iontovou chromatografií s vodivostní detekcí","parameters":[{"name":"Fluorków","range":""}],"parameters_en":[{"name":"Fluorides","range":""}],"parameters_zh":[{"name":"氟化物","range":""}],"parameters_cs":[{"name":"fluoridů","range":""}],"technique":"Chromatografia jonowa z detekcją konduktometryczną","technique_en":"Ion chromatography with conductivity detection","technique_zh":"离子色谱-电导检测法","technique_cs":"iontovou chromatografií s vodivostní detekcí","techniques":["Chromatografia jonowa z detekcją konduktometryczną"],"techniques_en":["Ion chromatography with conductivity detection"],"techniques_zh":["离子色谱-电导检测法"],"techniques_cs":["iontovou chromatografií s vodivostní detekcí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fluorków metodą chromatografii jonowej z detekcją konduktometryczną\nFluorków\nChromatografia jonowa z detekcją konduktometryczną","reference":"SOP 04/514 (ČSN P CEN/TS 17340; ČSN EN ISO 10304-1)","norm_bases":["SOP 04/514","ČSN P CEN/TS 17340","ČSN EN ISO 10304-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Roztwór absorpcyjny Oznaczanie fluorków metodą chromatografii jonowej z detekcją konduktometryczną Chromatografia jonowa z detekcją konduktometryczną Fluorków  Absorpční roztok Stanovení fluoridů iontovou chromatografií s vodivostní detekcí iontovou chromatografií s vodivostní detekcí fluoridů  SOP 04/514 (ČSN P CEN/TS 17340; ČSN EN ISO 10304-1) Roztwor absorpcyjny Oznaczanie fluorkow metoda chromatografii jonowej z detekcja konduktometryczna Chromatografia jonowa z detekcja konduktometryczna Fluorkow  Absorpcni roztok Stanoveni fluoridu iontovou chromatografii s vodivostni detekci iontovou chromatografii s vodivostni detekci fluoridu  SOP 04/514 (CSN P CEN/TS 17340; CSN EN ISO 10304-1)","search_en":"Absorption solution Determination of fluorides by ion chromatography with conductivity detection Ion chromatography with conductivity detection Fluorides  SOP 04/514 (ČSN P CEN/TS 17340; ČSN EN ISO 10304-1)","search_zh":"吸收液 离子色谱-电导检测法测定氟化物 离子色谱-电导检测法 氟化物  SOP 04/514 (ČSN P CEN/TS 17340; ČSN EN ISO 10304-1)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ac52dab25782ee5b2c08994","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"4","test_object":"Roztwór absorpcyjny","test_object_en":"Absorption solution","test_object_zh":"吸收液","test_object_cs":"Absorpční roztok","methodology":"Oznaczanie amoniaku metodą chromatografii jonowej z detekcją konduktometryczną","methodology_en":"Determination of ammonia by ion chromatography with conductivity detection","methodology_zh":"离子色谱-电导检测法测定氨","methodology_cs":"Stanovení amoniaku iontovou chromatografií s vodivostní detekcí","parameters":[{"name":"Amoniaku","range":""}],"parameters_en":[{"name":"Ammonia","range":""}],"parameters_zh":[{"name":"氨","range":""}],"parameters_cs":[{"name":"amoniaku","range":""}],"technique":"Chromatografia jonowa z detekcją konduktometryczną","technique_en":"Ion chromatography with conductivity detection","technique_zh":"离子色谱-电导检测法","technique_cs":"iontovou chromatografií s vodivostní detekcí","techniques":["Chromatografia jonowa z detekcją konduktometryczną"],"techniques_en":["Ion chromatography with conductivity detection"],"techniques_zh":["离子色谱-电导检测法"],"techniques_cs":["iontovou chromatografií s vodivostní detekcí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie amoniaku metodą chromatografii jonowej z detekcją konduktometryczną\nAmoniaku\nChromatografia jonowa z detekcją konduktometryczną","reference":"SOP 05/514 (ČSN 83 4728; ČSN EN ISO 10304-1)","norm_bases":["SOP 05/514","ČSN 83 4728","ČSN EN ISO 10304-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Roztwór absorpcyjny Oznaczanie amoniaku metodą chromatografii jonowej z detekcją konduktometryczną Chromatografia jonowa z detekcją konduktometryczną Amoniaku  Absorpční roztok Stanovení amoniaku iontovou chromatografií s vodivostní detekcí iontovou chromatografií s vodivostní detekcí amoniaku  SOP 05/514 (ČSN 83 4728; ČSN EN ISO 10304-1) Roztwor absorpcyjny Oznaczanie amoniaku metoda chromatografii jonowej z detekcja konduktometryczna Chromatografia jonowa z detekcja konduktometryczna Amoniaku  Absorpcni roztok Stanoveni amoniaku iontovou chromatografii s vodivostni detekci iontovou chromatografii s vodivostni detekci amoniaku  SOP 05/514 (CSN 83 4728; CSN EN ISO 10304-1)","search_en":"Absorption solution Determination of ammonia by ion chromatography with conductivity detection Ion chromatography with conductivity detection Ammonia  SOP 05/514 (ČSN 83 4728; ČSN EN ISO 10304-1)","search_zh":"吸收液 离子色谱-电导检测法测定氨 离子色谱-电导检测法 氨  SOP 05/514 (ČSN 83 4728; ČSN EN ISO 10304-1)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82b76fbd105d8a6e174e83f0","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"5","test_object":"Roztwór absorpcyjny, filtr, wody odpadowe i powierzchniowe, wyciąg wodny, materiały stałe","test_object_en":"Absorption solution, filter, waste and surface water, aqueous leachate, solid materials","test_object_zh":"吸收液、滤膜、废水和地表水、水浸出液、固体材料","test_object_cs":"Absorpční roztok, filtr, vody odpadní a povrchové, vodný výluh, pevné materiály","methodology":"Oznaczanie rtęci analizatorem AMA 254","methodology_en":"Determination of mercury by atomic absorption spectrometry with AMA254 analyzer","methodology_zh":"AMA 254分析仪原子吸收光谱法测定汞","methodology_cs":"Stanovení rtuti analyzátorem AMA 254","parameters":[{"name":"Rtęć (Hg)","range":""}],"parameters_en":[{"name":"Mercury","range":""}],"parameters_zh":[{"name":"汞 (Hg)","range":""}],"parameters_cs":[{"name":"rtuti","range":""}],"technique":"Atomowa spektrometria absorpcyjna, analizator AMA 254","technique_en":"Atomic absorption spectrometry with AMA254 analyzer","technique_zh":"AMA 254分析仪原子吸收光谱法","technique_cs":"analyzátorem AMA 254","techniques":["Atomowa spektrometria absorpcyjna, analizator AMA 254"],"techniques_en":["Atomic absorption spectrometry with AMA254 analyzer"],"techniques_zh":["AMA 254分析仪原子吸收光谱法"],"techniques_cs":["analyzátorem AMA 254"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci analizatorem AMA 254\nRtęć (Hg)\nAtomowa spektrometria absorpcyjna, analizator AMA 254","reference":"SOP 06/514 (ČSN 13211; Návod na obsluhu AMA 254)","norm_bases":["SOP 06/514","ČSN 13211","Návod na obsluhu AMA 254"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Literatura źródłowa: AMA 254 Advanced Mercury Analyser – instrukcja obsługi, wersja dla Windows 5.0.3, 2012 Wyciągi wodne: według rozporządzenia nr 294/2005 Sb. i rozporządzenia nr 273/2021 Sb.","note_en":"AMA 254 Advanced Mercury Analyser – User Manual, Windows version 5.0.3, 2012 Aqueous extracts: according to Decree No. 294/2005 Coll. and Decree No. 273/2021 Coll.","note_zh":"来源文献：AMA 254 Advanced Mercury Analyser 操作手册，Windows版5.0.3，2012 水浸出液：依据第294/2005 Sb.号法令和第273/2021 Sb.号法令","note_cs":"AMA 254 Advanced Mercury Analyser – Návod na obsluhu, verze pro Windows 5.0.3, 2012 Vodné výluhy: podle vyhlášky č. 294/2005 Sb. a vyhlášky č. 273/2021 Sb.","search_text":"Roztwór absorpcyjny, filtr, wody odpadowe i powierzchniowe, wyciąg wodny, materiały stałe Oznaczanie rtęci analizatorem AMA 254 Atomowa spektrometria absorpcyjna, analizator AMA 254 Rtęć (Hg)  Absorpční roztok, filtr, vody odpadní a povrchové, vodný výluh, pevné materiály Stanovení rtuti analyzátorem AMA 254 analyzátorem AMA 254 rtuti  SOP 06/514 (ČSN 13211; Návod na obsluhu AMA 254) Roztwor absorpcyjny, filtr, wody odpadowe i powierzchniowe, wyciag wodny, materialy stale Oznaczanie rteci analizatorem AMA 254 Atomowa spektrometria absorpcyjna, analizator AMA 254 Rtec (Hg)  Absorpcni roztok, filtr, vody odpadni a povrchove, vodny vyluh, pevne materialy Stanoveni rtuti analyzatorem AMA 254 analyzatorem AMA 254 rtuti  SOP 06/514 (CSN 13211; Navod na obsluhu AMA 254)","search_en":"Absorption solution, filter, waste and surface water, aqueous leachate, solid materials Determination of mercury by atomic absorption spectrometry with AMA254 analyzer Atomic absorption spectrometry with AMA254 analyzer Mercury  SOP 06/514 (ČSN 13211; Návod na obsluhu AMA 254)","search_zh":"吸收液、滤膜、废水和地表水、水浸出液、固体材料 AMA 254分析仪原子吸收光谱法测定汞 AMA 254分析仪原子吸收光谱法 汞 (Hg)  SOP 06/514 (ČSN 13211; Návod na obsluhu AMA 254)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"782cc4f782696de887c75c3f","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"6","test_object":"Wody odpadowe i powierzchniowe, wyciąg wodny","test_object_en":"Waste and surface water, aqueous leachate","test_object_zh":"废水和地表水、水浸出液","test_object_cs":"Vody odpadní a povrchové, vodný výluh","methodology":"Oznaczanie anionów metodą chromatografii jonowej","methodology_en":"Determination of anions by ion chromatography","methodology_zh":"离子色谱法测定阴离子","methodology_cs":"Stanovení aniontů iontovou chromatografií","parameters":[{"name":"Bromki","range":""},{"name":"Azotyny","range":""},{"name":"Fluorki","range":""},{"name":"Fosforany","range":""},{"name":"Chlorki","range":""},{"name":"Siarczany","range":""}],"parameters_en":[{"name":"Bromides","range":""},{"name":"Nitrites","range":""},{"name":"Fluorides","range":""},{"name":"Phosphates","range":""},{"name":"Chlorides","range":""},{"name":"Sulphates","range":""}],"parameters_zh":[{"name":"溴化物","range":""},{"name":"亚硝酸盐","range":""},{"name":"氟化物","range":""},{"name":"磷酸盐","range":""},{"name":"氯化物","range":""},{"name":"硫酸盐","range":""}],"parameters_cs":[{"name":"bromidy","range":""},{"name":"dusitany","range":""},{"name":"fluoridy","range":""},{"name":"fosforečnany","range":""},{"name":"chloridy","range":""},{"name":"sírany","range":""}],"technique":"Chromatografia jonowa","technique_en":"Ion chromatography","technique_zh":"离子色谱法","technique_cs":"iontovou chromatografií","techniques":["Chromatografia jonowa"],"techniques_en":["Ion chromatography"],"techniques_zh":["离子色谱法"],"techniques_cs":["iontovou chromatografií"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionów metodą chromatografii jonowej\nZakres:\nBromki\nAzotyny\nFluorki\nFosforany\nChlorki\nSiarczany\nChromatografia jonowa","reference":"SOP 07/514 (ČSN EN ISO 10304-1)","norm_bases":["SOP 07/514","ČSN EN ISO 10304-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: bromki, azotyny, fluorki, fosforany, chlorki, siarczany Wyciągi wodne: według rozporządzenia nr 294/2005 Sb. i rozporządzenia nr 273/2021 Sb.","note_en":"bromides, nitrites, fluorides, phosphates, chlorides, sulphates Aqueous extracts: according to Decree No. 294/2005 Coll. and Decree No. 273/2021 Coll.","note_zh":"测定的分析物：溴化物、亚硝酸盐、氟化物、磷酸盐、氯化物、硫酸盐 水浸出液：依据第294/2005 Sb.号法令和第273/2021 Sb.号法令","note_cs":"bromidy, dusitany, fluoridy, fosforečnany, chloridy, sírany Vodné výluhy: podle vyhlášky č. 294/2005 Sb. a vyhlášky č. 273/2021 Sb.","search_text":"Wody odpadowe i powierzchniowe, wyciąg wodny Oznaczanie anionów metodą chromatografii jonowej Chromatografia jonowa Bromki  Azotyny  Fluorki  Fosforany  Chlorki  Siarczany  Vody odpadní a povrchové, vodný výluh Stanovení aniontů iontovou chromatografií iontovou chromatografií bromidy  dusitany  fluoridy  fosforečnany  chloridy  sírany  SOP 07/514 (ČSN EN ISO 10304-1) Wody odpadowe i powierzchniowe, wyciag wodny Oznaczanie anionow metoda chromatografii jonowej Chromatografia jonowa Bromki  Azotyny  Fluorki  Fosforany  Chlorki  Siarczany  Vody odpadni a povrchove, vodny vyluh Stanoveni aniontu iontovou chromatografii iontovou chromatografii bromidy  dusitany  fluoridy  fosforecnany  chloridy  sirany  SOP 07/514 (CSN EN ISO 10304-1)","search_en":"Waste and surface water, aqueous leachate Determination of anions by ion chromatography Ion chromatography Bromides  Nitrites  Fluorides  Phosphates  Chlorides  Sulphates  SOP 07/514 (ČSN EN ISO 10304-1)","search_zh":"废水和地表水、水浸出液 离子色谱法测定阴离子 离子色谱法 溴化物  亚硝酸盐  氟化物  磷酸盐  氯化物  硫酸盐  SOP 07/514 (ČSN EN ISO 10304-1)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"299bb0202dda0c34183f0950","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"7","test_object":"Wody odpadowe i powierzchniowe, wyciąg wodny","test_object_en":"Waste and surface water, aqueous leachate","test_object_zh":"废水和地表水、水浸出液","test_object_cs":"Vody odpadní a povrchové, vodný výluh","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda potencjometryczna","technique_en":"Potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["Metoda potencjometryczna"],"techniques_en":["Potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną\nMetoda potencjometryczna","reference":"SOP 08/514 (ČSN ISO 10523)","norm_bases":["SOP 08/514","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wyciągi wodne: według rozporządzenia nr 294/2005 Sb. i rozporządzenia nr 273/2021 Sb.","note_en":"Aqueous extracts: according to Decree No. 294/2005 Coll. and Decree No. 273/2021 Coll.","note_zh":"水浸出液：依据第294/2005 Sb.号法令和第273/2021 Sb.号法令","note_cs":"Vodné výluhy: podle vyhlášky č. 294/2005 Sb. a vyhlášky č. 273/2021 Sb.","search_text":"Wody odpadowe i powierzchniowe, wyciąg wodny Oznaczanie pH metodą potencjometryczną Metoda potencjometryczna Vody odpadní a povrchové, vodný výluh Stanovení pH potenciometricky potenciometricky SOP 08/514 (ČSN ISO 10523) Wody odpadowe i powierzchniowe, wyciag wodny Oznaczanie pH metoda potencjometryczna Metoda potencjometryczna Vody odpadni a povrchove, vodny vyluh Stanoveni pH potenciometricky potenciometricky SOP 08/514 (CSN ISO 10523)","search_en":"Waste and surface water, aqueous leachate Determination of pH by potentiometry Potentiometry SOP 08/514 (ČSN ISO 10523)","search_zh":"废水和地表水、水浸出液 电位法测定pH 电位法 SOP 08/514 (ČSN ISO 10523)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"170ed0bd1789db88913701cc","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"8","test_object":"Wody odpadowe i powierzchniowe, wyciąg wodny","test_object_en":"Waste and surface water, aqueous leachate","test_object_zh":"废水和地表水、水浸出液","test_object_cs":"Vody odpadní a povrchové, vodný výluh","methodology":"Oznaczanie przewodności elektrycznej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率的测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej","reference":"SOP 08/514 (ČSN EN 27888)","norm_bases":["SOP 08/514","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wyciągi wodne: według rozporządzenia nr 294/2005 Sb. i rozporządzenia nr 273/2021 Sb.","note_en":"Aqueous extracts: according to Decree No. 294/2005 Coll. and Decree No. 273/2021 Coll.","note_zh":"水浸出液：依据第294/2005 Sb.号法令和第273/2021 Sb.号法令","note_cs":"Vodné výluhy: podle vyhlášky č. 294/2005 Sb. a vyhlášky č. 273/2021 Sb.","search_text":"Wody odpadowe i powierzchniowe, wyciąg wodny Oznaczanie przewodności elektrycznej Vody odpadní a povrchové, vodný výluh Stanovení elektrické konduktivity SOP 08/514 (ČSN EN 27888) Wody odpadowe i powierzchniowe, wyciag wodny Oznaczanie przewodnosci elektrycznej Vody odpadni a povrchove, vodny vyluh Stanoveni elektricke konduktivity SOP 08/514 (CSN EN 27888)","search_en":"Waste and surface water, aqueous leachate Determination of electrical conductivity SOP 08/514 (ČSN EN 27888)","search_zh":"废水和地表水、水浸出液 电导率的测定 SOP 08/514 (ČSN EN 27888)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a055600afbdbc8ed9a45edc0","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"9","test_object":"Wody odpadowe i powierzchniowe, wyciąg wodny","test_object_en":"Waste and surface water, aqueous leachate","test_object_zh":"废水和地表水、水浸出液","test_object_cs":"Vody odpadní a povrchové, vodný výluh","methodology":"Oznaczanie substancji rozpuszczonych metodą wagową","methodology_en":"Determination of dissolved solids by gravimetry","methodology_zh":"重量法测定溶解性固体","methodology_cs":"Stanovení rozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda wagowa","technique_en":"Gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych metodą wagową\nMetoda wagowa","reference":"SOP 09/514 (ČSN EN 15216)","norm_bases":["SOP 09/514","ČSN EN 15216"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wyciągi wodne: według rozporządzenia nr 294/2005 Sb. i rozporządzenia nr 273/2021 Sb.","note_en":"Aqueous extracts: according to Decree No. 294/2005 Coll. and Decree No. 273/2021 Coll.","note_zh":"水浸出液：依据第294/2005 Sb.号法令和第273/2021 Sb.号法令","note_cs":"Vodné výluhy: podle vyhlášky č. 294/2005 Sb. a vyhlášky č. 273/2021 Sb.","search_text":"Wody odpadowe i powierzchniowe, wyciąg wodny Oznaczanie substancji rozpuszczonych metodą wagową Metoda wagowa Vody odpadní a povrchové, vodný výluh Stanovení rozpuštěných látek gravimetricky gravimetricky SOP 09/514 (ČSN EN 15216) Wody odpadowe i powierzchniowe, wyciag wodny Oznaczanie substancji rozpuszczonych metoda wagowa Metoda wagowa Vody odpadni a povrchove, vodny vyluh Stanoveni rozpustenych latek gravimetricky gravimetricky SOP 09/514 (CSN EN 15216)","search_en":"Waste and surface water, aqueous leachate Determination of dissolved solids by gravimetry Gravimetry SOP 09/514 (ČSN EN 15216)","search_zh":"废水和地表水、水浸出液 重量法测定溶解性固体 重量法 SOP 09/514 (ČSN EN 15216)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"01bbfbd16f9bbf9b60a02688","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"10","test_object":"Roztwór absorpcyjny, roztwór z płukania, filtr, wody odpadowe i powierzchniowe, wyciąg wodny, materiały stałe","test_object_en":"Absorption solution, rinse solution, filter, waste and surface water, aqueous leachate, solid materials","test_object_zh":"吸收液、冲洗液、滤膜、废水和地表水、水浸出液、固体材料","test_object_cs":"Absorpční roztok, oplachový roztok, filtr, vody odpadní a povrchové, vodný výluh, pevné materiály","methodology":"Oznaczanie pierwiastków metodą ICP-MS","methodology_en":"Determination of elements by ICP-MS method","methodology_zh":"ICP-MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP-MS","parameters":[{"name":"Antymon","range":""},{"name":"Arsen","range":""},{"name":"Bar","range":""},{"name":"Beryl","range":""},{"name":"Bor","range":""},{"name":"Cyna","range":""},{"name":"Potas","range":""},{"name":"Fosfor","range":""},{"name":"Glin","range":""},{"name":"Magnez","range":""},{"name":"Chrom","range":""},{"name":"Kadm","range":""},{"name":"Kobalt","range":""},{"name":"Krzem","range":""},{"name":"Lit","range":""},{"name":"Mangan","range":""},{"name":"Miedź","range":""},{"name":"Nikiel","range":""},{"name":"Ołów","range":""},{"name":"Selen","range":""},{"name":"Siarka","range":""},{"name":"Sód","range":""},{"name":"Tal","range":""},{"name":"Tytan","range":""},{"name":"Wanad","range":""},{"name":"Wapń","range":""},{"name":"Cynk","range":""},{"name":"Żelazo","range":""}],"parameters_en":[{"name":"Antimony","range":""},{"name":"Arsenic","range":""},{"name":"Barium","range":""},{"name":"Beryllium","range":""},{"name":"Boron","range":""},{"name":"Tin","range":""},{"name":"Potassium","range":""},{"name":"Phosphorus","range":""},{"name":"Aluminium","range":""},{"name":"Magnesium","range":""},{"name":"Chromium","range":""},{"name":"Cadmium","range":""},{"name":"Cobalt","range":""},{"name":"Silicon","range":""},{"name":"Lithium","range":""},{"name":"Manganese","range":""},{"name":"Copper","range":""},{"name":"Nickel","range":""},{"name":"Lead","range":""},{"name":"Selenium","range":""},{"name":"Sulphur","range":""},{"name":"Sodium","range":""},{"name":"Thallium","range":""},{"name":"Titanium","range":""},{"name":"Vanadium","range":""},{"name":"Calcium","range":""},{"name":"Zinc","range":""},{"name":"Iron","range":""}],"parameters_zh":[{"name":"锑","range":""},{"name":"砷","range":""},{"name":"钡","range":""},{"name":"铍","range":""},{"name":"硼","range":""},{"name":"锡","range":""},{"name":"钾","range":""},{"name":"磷","range":""},{"name":"铝","range":""},{"name":"镁","range":""},{"name":"铬","range":""},{"name":"镉","range":""},{"name":"钴","range":""},{"name":"硅","range":""},{"name":"锂","range":""},{"name":"锰","range":""},{"name":"铜","range":""},{"name":"镍","range":""},{"name":"铅","range":""},{"name":"硒","range":""},{"name":"硫","range":""},{"name":"钠","range":""},{"name":"铊","range":""},{"name":"钛","range":""},{"name":"钒","range":""},{"name":"钙","range":""},{"name":"锌","range":""},{"name":"铁","range":""}],"parameters_cs":[{"name":"antimon","range":""},{"name":"arsen","range":""},{"name":"baryum","range":""},{"name":"berylium","range":""},{"name":"bor","range":""},{"name":"cín","range":""},{"name":"draslík","range":""},{"name":"fosfor","range":""},{"name":"hliník","range":""},{"name":"hořčík","range":""},{"name":"chrom","range":""},{"name":"kadmium","range":""},{"name":"kobalt","range":""},{"name":"křemík","range":""},{"name":"lithium","range":""},{"name":"mangan","range":""},{"name":"měď","range":""},{"name":"nikl","range":""},{"name":"olovo","range":""},{"name":"selen","range":""},{"name":"síra","range":""},{"name":"sodík","range":""},{"name":"thalium","range":""},{"name":"titan","range":""},{"name":"vanad","range":""},{"name":"vápník","range":""},{"name":"zinek","range":""},{"name":"železo","range":""}],"technique":"Spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","technique_en":"ICP-MS method","technique_zh":"电感耦合等离子体质谱法 (ICP-MS)","technique_cs":"metodou ICP-MS","techniques":["Spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)"],"techniques_en":["ICP-MS method"],"techniques_zh":["电感耦合等离子体质谱法 (ICP-MS)"],"techniques_cs":["metodou ICP-MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP-MS\nZakres:\nAntymon\nArsen\nBar\nBeryl\nBor\nCyna\nPotas\nFosfor\nGlin\nMagnez\nChrom\nKadm\nKobalt\nKrzem\nLit\nMangan\nMiedź\nNikiel\nOłów\nSelen\nSiarka\nSód\nTal\nTytan\nWanad\nWapń\nCynk\nŻelazo\nSpektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","reference":"SOP 10/514 (ČSN EN 14385; ČSN EN ISO 11885)","norm_bases":["SOP 10/514","ČSN EN 14385","ČSN EN ISO 11885"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: antymon, arsen, bar, beryl, bor, cyna, potas, fosfor, glin, magnez, chrom, kadm, kobalt, krzem, lit, mangan, miedź, nikiel, ołów, selen, siarka, sód, tal, tytan, wanad, wapń, cynk, żelazo Wyciągi wodne: według rozporządzenia nr 294/2005 Sb. i rozporządzenia nr 273/2021 Sb.","note_en":"antimony, arsenic, barium, beryllium, boron, tin, potassium, phosphorus, aluminium, magnesium, chromium, cadmium, cobalt, silicon, lithium, manganese, copper, nickel, lead, selenium, sulphur, sodium, thallium, titanium, vanadium, calcium, zinc, iron Aqueous extracts: according to Decree No. 294/2005 Coll. and Decree No. 273/2021 Coll.","note_zh":"测定的分析物：锑、砷、钡、铍、硼、锡、钾、磷、铝、镁、铬、镉、钴、硅、锂、锰、铜、镍、铅、硒、硫、钠、铊、钛、钒、钙、锌、铁 水浸出液：依据第294/2005 Sb.号法令和第273/2021 Sb.号法令","note_cs":"antimon, arsen, baryum, berylium, bor, cín, draslík, fosfor, hliník, hořčík, chrom, kadmium, kobalt, křemík, lithium, mangan, měď, nikl, olovo, selen, síra, sodík, thalium, titan, vanad, vápník, zinek, železo Vodné výluhy: podle vyhlášky č. 294/2005 Sb. a vyhlášky č. 273/2021 Sb.","search_text":"Roztwór absorpcyjny, roztwór z płukania, filtr, wody odpadowe i powierzchniowe, wyciąg wodny, materiały stałe Oznaczanie pierwiastków metodą ICP-MS Spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS) Antymon  Arsen  Bar  Beryl  Bor  Cyna  Potas  Fosfor  Glin  Magnez  Chrom  Kadm  Kobalt  Krzem  Lit  Mangan  Miedź  Nikiel  Ołów  Selen  Siarka  Sód  Tal  Tytan  Wanad  Wapń  Cynk  Żelazo  Absorpční roztok, oplachový roztok, filtr, vody odpadní a povrchové, vodný výluh, pevné materiály Stanovení prvků metodou ICP-MS metodou ICP-MS antimon  arsen  baryum  berylium  bor  cín  draslík  fosfor  hliník  hořčík  chrom  kadmium  kobalt  křemík  lithium  mangan  měď  nikl  olovo  selen  síra  sodík  thalium  titan  vanad  vápník  zinek  železo  SOP 10/514 (ČSN EN 14385; ČSN EN ISO 11885) Roztwor absorpcyjny, roztwor z plukania, filtr, wody odpadowe i powierzchniowe, wyciag wodny, materialy stale Oznaczanie pierwiastkow metoda ICP-MS Spektrometria mas z plazma wzbudzona indukcyjnie (ICP-MS) Antymon  Arsen  Bar  Beryl  Bor  Cyna  Potas  Fosfor  Glin  Magnez  Chrom  Kadm  Kobalt  Krzem  Lit  Mangan  Miedz  Nikiel  Olow  Selen  Siarka  Sod  Tal  Tytan  Wanad  Wapn  Cynk  Zelazo  Absorpcni roztok, oplachovy roztok, filtr, vody odpadni a povrchove, vodny vyluh, pevne materialy Stanoveni prvku metodou ICP-MS metodou ICP-MS antimon  arsen  baryum  berylium  bor  cin  draslik  fosfor  hlinik  horcik  chrom  kadmium  kobalt  kremik  lithium  mangan  med  nikl  olovo  selen  sira  sodik  thalium  titan  vanad  vapnik  zinek  zelezo  SOP 10/514 (CSN EN 14385; CSN EN ISO 11885)","search_en":"Absorption solution, rinse solution, filter, waste and surface water, aqueous leachate, solid materials Determination of elements by ICP-MS method ICP-MS method Antimony  Arsenic  Barium  Beryllium  Boron  Tin  Potassium  Phosphorus  Aluminium  Magnesium  Chromium  Cadmium  Cobalt  Silicon  Lithium  Manganese  Copper  Nickel  Lead  Selenium  Sulphur  Sodium  Thallium  Titanium  Vanadium  Calcium  Zinc  Iron  SOP 10/514 (ČSN EN 14385; ČSN EN ISO 11885)","search_zh":"吸收液、冲洗液、滤膜、废水和地表水、水浸出液、固体材料 ICP-MS法测定元素 电感耦合等离子体质谱法 (ICP-MS) 锑  砷  钡  铍  硼  锡  钾  磷  铝  镁  铬  镉  钴  硅  锂  锰  铜  镍  铅  硒  硫  钠  铊  钛  钒  钙  锌  铁  SOP 10/514 (ČSN EN 14385; ČSN EN ISO 11885)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c510247c9335ea5789da70b1","lab_id":"69ad52a4de79e566650fd572","country":"CZ","accr_number":"1733","accr_body":"ČIA","row_label":"1","test_object":"Materiały sypkie i ziarniste","test_object_en":"Bulk and granular materials","test_object_zh":"散装和颗粒材料","test_object_cs":"Sypké a zrnité materiály","methodology":"Ręczne pobieranie próbek materiałów sypkich i ziarnistych","methodology_en":"Manual sampling of bulk and granular materials","methodology_zh":"散装和颗粒材料手工采样","methodology_cs":"Odběr vzorků sypkých a zrnitých materiálů manuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ręczne pobieranie próbek materiałów sypkich i ziarnistych","reference":"SOP 11/514 (ČSN 01 5111)","norm_bases":["SOP 11/514","ČSN 01 5111"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały sypkie i ziarniste Ręczne pobieranie próbek materiałów sypkich i ziarnistych Sypké a zrnité materiály Odběr vzorků sypkých a zrnitých materiálů manuálně SOP 11/514 (ČSN 01 5111) Materialy sypkie i ziarniste Reczne pobieranie probek materialow sypkich i ziarnistych Sypke a zrnite materialy Odber vzorku sypkych a zrnitych materialu manualne SOP 11/514 (CSN 01 5111)","search_en":"Bulk and granular materials Manual sampling of bulk and granular materials SOP 11/514 (ČSN 01 5111)","search_zh":"散装和颗粒材料 散装和颗粒材料手工采样 SOP 11/514 (ČSN 01 5111)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}