{"lab":{"_id":"69ad52a4de79e566650fd570","country":"CZ","accr_number":"1732","accr_body":"ČIA","address":"Průmyslová 1004, 294 71 Benátky nad Jizerou","categories":["materials"],"city":"Benátky nad Jizerou","imported_at":"2026-03-08T10:42:44.590Z","methods_count":2,"name":"Target Technologie s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1732_619_2021_CS.pdf","1732_619_2021_EN.pdf"],"scope_summary":"Badania w zakresie badań chemicznych i mechanicznych materiałów stalowych.","search_text":"target technologie s.r.o. průmyslová 1004, 294 71 benátky nad jizerou 1732","status":"active","updated_at":"2026-03-08T14:52:15.620Z","valid_from":"","valid_until":"30-11-2026","website":"http://www.target-technologie.cz","email_confidence":"high","email_mx":true,"email_source":"http://www.target-technologie.cz","map_coord":[50.268031,14.856949],"map_geo":"nominatim-street","certificate_date":"30.11.2021","certificate_no":"619/2021","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania w zakresie badań chemicznych i mechanicznych materiałów stalowych.","en":"Tests in the field of chemical and mechanical testing of steel materials.","zh":"钢材化学和力学检测领域的试验。","cs":"Zkoušky v oblasti chemického a mechanického zkoušení ocelových materiálů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Materiałowe","lab_division_cs":"Materiálová laboratoř","lab_division_en":"Material Laboratory","lab_division_zh":"材料实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"OES","pl":"Optyczna spektrometria emisyjna","en":"Optical Emission Spectrometry","zh":"光学发射光谱法","cs":"optická emisní spektrometrie"},{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard Operating Procedure","zh":"标准操作程序","cs":"standardní operační postup"},{"abbr":"ASTM","pl":"American Society for Testing and Materials","en":"American Society for Testing and Materials","zh":"美国材料与试验协会","cs":"American Society for testing and materials"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"9ea137e5472300d0fc9d2e724f25215a33b7799e39c9757290bbe75477a614f8","source_pdf_url":"https://www.cai.cz/OA/pdf/P619_2021_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P619_2021_EN.pdf"},"methods":[{"_id":"5ec8ea4f0ad8ef65d746664c","lab_id":"69ad52a4de79e566650fd570","country":"CZ","accr_number":"1732","accr_body":"ČIA","row_label":"1","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Oznaczanie zawartości pierwiastków metodą OES","methodology_en":"Determination of the content of elements by OES method","methodology_zh":"OES法测定元素含量","methodology_cs":"Stanovení obsahu prvků metodou OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Węgiel (C)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Niob (Nb)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Siarka (S)","range":""},{"name":"Krzem (Si)","range":""},{"name":"Tytan (Ti)","range":""},{"name":"Wanad (V)","range":""}],"parameters_en":[{"name":"Al","range":""},{"name":"B","range":""},{"name":"C","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Nb","range":""},{"name":"P","range":""},{"name":"S","range":""},{"name":"Si","range":""},{"name":"Ti","range":""},{"name":"V","range":""}],"parameters_zh":[{"name":"铝 (Al)","range":""},{"name":"硼 (B)","range":""},{"name":"碳 (C)","range":""},{"name":"铬 (Cr)","range":""},{"name":"铜 (Cu)","range":""},{"name":"锰 (Mn)","range":""},{"name":"钼 (Mo)","range":""},{"name":"铌 (Nb)","range":""},{"name":"磷 (P)","range":""},{"name":"硫 (S)","range":""},{"name":"硅 (Si)","range":""},{"name":"钛 (Ti)","range":""},{"name":"钒 (V)","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"B","range":""},{"name":"C","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Nb","range":""},{"name":"P","range":""},{"name":"S","range":""},{"name":"Si","range":""},{"name":"Ti","range":""},{"name":"V","range":""}],"technique":"Metoda OES (optyczna spektrometria emisyjna)","technique_en":"OES method","technique_zh":"OES法（光学发射光谱法）","technique_cs":"metodou OES","techniques":["Metoda OES (optyczna spektrometria emisyjna)"],"techniques_en":["OES method"],"techniques_zh":["OES法（光学发射光谱法）"],"techniques_cs":["metodou OES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości pierwiastków metodą OES\nZakres:\nGlin (Al)\nBor (B)\nWęgiel (C)\nChrom (Cr)\nMiedź (Cu)\nMangan (Mn)\nMolibden (Mo)\nNiob (Nb)\nFosfor (P)\nSiarka (S)\nKrzem (Si)\nTytan (Ti)\nWanad (V)\nMetoda OES (optyczna spektrometria emisyjna)","reference":"SOP 01 (ČSN EN 10020, ASTM A751, Uživatelský manuál Spektrometr Q4 Tasman)","norm_bases":["SOP 01","ČSN EN 10020","ASTM A751","Uživatelský manuál Spektrometr Q4 Tasman"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Oznaczanie zawartości pierwiastków metodą OES Metoda OES (optyczna spektrometria emisyjna) Glin (Al)  Bor (B)  Węgiel (C)  Chrom (Cr)  Miedź (Cu)  Mangan (Mn)  Molibden (Mo)  Niob (Nb)  Fosfor (P)  Siarka (S)  Krzem (Si)  Tytan (Ti)  Wanad (V)  Oceli Stanovení obsahu prvků metodou OES metodou OES Al  B  C  Cr  Cu  Mn  Mo  Nb  P  S  Si  Ti  V  SOP 01 (ČSN EN 10020, ASTM A751, Uživatelský manuál Spektrometr Q4 Tasman) Stale Oznaczanie zawartosci pierwiastkow metoda OES Metoda OES (optyczna spektrometria emisyjna) Glin (Al)  Bor (B)  Wegiel (C)  Chrom (Cr)  Miedz (Cu)  Mangan (Mn)  Molibden (Mo)  Niob (Nb)  Fosfor (P)  Siarka (S)  Krzem (Si)  Tytan (Ti)  Wanad (V)  Oceli Stanoveni obsahu prvku metodou OES metodou OES Al  B  C  Cr  Cu  Mn  Mo  Nb  P  S  Si  Ti  V  SOP 01 (CSN EN 10020, ASTM A751, Uzivatelsky manual Spektrometr Q4 Tasman)","search_en":"Steel Determination of the content of elements by OES method OES method Al  B  C  Cr  Cu  Mn  Mo  Nb  P  S  Si  Ti  V  SOP 01 (ČSN EN 10020, ASTM A751, Uživatelský manuál Spektrometr Q4 Tasman)","search_zh":"钢 OES法测定元素含量 OES法（光学发射光谱法） 铝 (Al)  硼 (B)  碳 (C)  铬 (Cr)  铜 (Cu)  锰 (Mn)  钼 (Mo)  铌 (Nb)  磷 (P)  硫 (S)  硅 (Si)  钛 (Ti)  钒 (V)  SOP 01 (ČSN EN 10020, ASTM A751, Uživatelský manuál Spektrometr Q4 Tasman)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"235e8b85cf78ec377715e377","lab_id":"69ad52a4de79e566650fd570","country":"CZ","accr_number":"1732","accr_body":"ČIA","row_label":"2","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Próba rozciągania w temperaturze pokojowej","methodology_en":"Tensile test at room temperature","methodology_zh":"室温拉伸试验","methodology_cs":"Zkouška tahem za pokojové teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba rozciągania w temperaturze pokojowej","reference":"SOP 02 (ČSN EN ISO 6892-1)","norm_bases":["SOP 02","ČSN EN ISO 6892-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Próba rozciągania w temperaturze pokojowej Oceli Zkouška tahem za pokojové teploty SOP 02 (ČSN EN ISO 6892-1) Stale Proba rozciagania w temperaturze pokojowej Oceli Zkouska tahem za pokojove teploty SOP 02 (CSN EN ISO 6892-1)","search_en":"Steel Tensile test at room temperature SOP 02 (ČSN EN ISO 6892-1)","search_zh":"钢 室温拉伸试验 SOP 02 (ČSN EN ISO 6892-1)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}