{"lab":{"_id":"69ad52a4de79e566650fd568","accr_number":"1728","country":"CZ","accr_body":"ČIA","address":"Nádražní 395/25, 789 85 Mohelnice","categories":["electronics"],"city":"Mohelnice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":14,"name":"Innomotics, s.r.o., odštěpný závod Elektromotory Mohelnice","parse_status":"parsed","parse_version":5,"pdf_files":["1728_328_2025_CS.pdf","1728_328_2025_EN.pdf"],"scope_summary":"Badania maszyn elektrycznych wirujących, w zakresie określonym w załączniku do świadectwa.","search_text":"innomotics, s.r.o., odštěpný závod elektromotory mohelnice nádražní 395/25, 789 85 mohelnice other","status":"active","updated_at":"2026-03-08T14:52:15.453Z","valid_from":"","valid_until":"25-06-2031","website":"","parsed_at":"2026-09-28T12:00:00.000Z","map_coord":[49.777745,16.932559],"map_geo":"nominatim-street","certificate_date":"25.06.2026","certificate_no":"314/2026","certificate_replaces":"328/2025 z 30.06.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania maszyn elektrycznych wirujących, w zakresie określonym w załączniku do świadectwa.","en":"Tests of rotating electrical machines to the extent as specified in the appendix to this Certificate.","zh":"旋转电机检测，范围见本证书附件。","cs":"Zkoušky točivých elektrických strojů, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium badań maszyn elektrycznych","lab_division_cs":"Zkušebna elektrických strojů","lab_division_en":"Testing Laboratory for Electrical Machines","lab_division_zh":"电机检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"IEEE","pl":"norma wydana przez American Institute of Electrical and Electronics Engineers","en":"Standard published by the American Institute of Electrical and Electronics Engineers","zh":"美国电气与电子工程师协会发布的标准","cs":"norma vydaná American Institute of Electrical and Electronics Engineers"},{"abbr":"C390:22","pl":"norma wydana przez Canadian Standards Association (CSA)","en":"Standard published by the Canadian Standards Association (CSA)","zh":"加拿大标准协会（CSA）发布的标准","cs":"norma vydaná Canadian Standards Association (CSA)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"f5dffe46f784b43c3353f5d9f41039528e41e887a23dc876c49ea609b667ebee","source_pdf_url":"https://www.cai.cz/OA/pdf/314_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/314_2026_EN.pdf"},"methods":[{"_id":"9de298bb4242b81cbd622bc1","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"1","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Pomiar rezystancji izolacji","methodology_en":"Measurement of insulation resistance","methodology_zh":"绝缘电阻测量","methodology_cs":"Měření izolačního odporu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar rezystancji izolacji","reference":"IEC 60034-27-4 ed. 1, čl. 6; IEEE Std 43:2013, čl. 7, 8, 9.1, 10, 12","norm_bases":["IEC 60034-27-4 ed. 1, čl. 6","IEEE Std 43:2013, čl. 7, 8, 9.1, 10, 12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Pomiar rezystancji izolacji Točivé elektrické stroje Měření izolačního odporu IEC 60034-27-4 ed. 1, čl. 6; IEEE Std 43:2013, čl. 7, 8, 9.1, 10, 12 Maszyny elektryczne wirujace Pomiar rezystancji izolacji Tocive elektricke stroje Mereni izolacniho odporu IEC 60034-27-4 ed. 1, cl. 6; IEEE Std 43:2013, cl. 7, 8, 9.1, 10, 12","search_en":"Rotating electrical machines Measurement of insulation resistance IEC 60034-27-4 ed. 1, čl. 6; IEEE Std 43:2013, čl. 7, 8, 9.1, 10, 12","search_zh":"旋转电机 绝缘电阻测量 IEC 60034-27-4 ed. 1, čl. 6; IEEE Std 43:2013, čl. 7, 8, 9.1, 10, 12","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"93b99ec2ae03f7d59456e74f","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"2","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Pomiar rezystancji","methodology_en":"Measurement of resistance","methodology_zh":"电阻测量","methodology_cs":"Měření odporu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar rezystancji","reference":"IEC 60034-1 ed. 14, čl. 8.6.2; IEC 60034-2-1 ed. 3, čl. 5.7; IEEE Std 118:1978, čl. 4.1, 4.7","norm_bases":["IEC 60034-1 ed. 14, čl. 8.6.2","IEC 60034-2-1 ed. 3, čl. 5.7","IEEE Std 118:1978, čl. 4.1, 4.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Pomiar rezystancji Točivé elektrické stroje Měření odporu IEC 60034-1 ed. 14, čl. 8.6.2; IEC 60034-2-1 ed. 3, čl. 5.7; IEEE Std 118:1978, čl. 4.1, 4.7 Maszyny elektryczne wirujace Pomiar rezystancji Tocive elektricke stroje Mereni odporu IEC 60034-1 ed. 14, cl. 8.6.2; IEC 60034-2-1 ed. 3, cl. 5.7; IEEE Std 118:1978, cl. 4.1, 4.7","search_en":"Rotating electrical machines Measurement of resistance IEC 60034-1 ed. 14, čl. 8.6.2; IEC 60034-2-1 ed. 3, čl. 5.7; IEEE Std 118:1978, čl. 4.1, 4.7","search_zh":"旋转电机 电阻测量 IEC 60034-1 ed. 14, čl. 8.6.2; IEC 60034-2-1 ed. 3, čl. 5.7; IEEE Std 118:1978, čl. 4.1, 4.7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"02bf92e996356d07cb5f87da","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"3","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Próba napięciowa wytrzymałości izolacji","methodology_en":"Voltage withstand test","methodology_zh":"耐电压试验","methodology_cs":"Zkouška výdržným napětím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba napięciowa wytrzymałości izolacji","reference":"IEC 60034-1 ed. 14, čl. 9.2; IEEE Std 112:2017, čl. 3.3, 8.2","norm_bases":["IEC 60034-1 ed. 14, čl. 9.2","IEEE Std 112:2017, čl. 3.3, 8.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Próba napięciowa wytrzymałości izolacji Točivé elektrické stroje Zkouška výdržným napětím IEC 60034-1 ed. 14, čl. 9.2; IEEE Std 112:2017, čl. 3.3, 8.2 Maszyny elektryczne wirujace Proba napieciowa wytrzymalosci izolacji Tocive elektricke stroje Zkouska vydrznym napetim IEC 60034-1 ed. 14, cl. 9.2; IEEE Std 112:2017, cl. 3.3, 8.2","search_en":"Rotating electrical machines Voltage withstand test IEC 60034-1 ed. 14, čl. 9.2; IEEE Std 112:2017, čl. 3.3, 8.2","search_zh":"旋转电机 耐电压试验 IEC 60034-1 ed. 14, čl. 9.2; IEEE Std 112:2017, čl. 3.3, 8.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9bc451051f2c52b63bc52be","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"4","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Próba nagrzewania","methodology_en":"Temperature-rise test","methodology_zh":"温升试验","methodology_cs":"Zkouška oteplení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba nagrzewania","reference":"IEC 60034-1 ed. 14, čl. 8; IEEE Std 112:2017, čl. 3.3, 4.4, 5.9; C390:22, čl. 5, 7.1.2, 7.1.3","norm_bases":["IEC 60034-1 ed. 14, čl. 8","IEEE Std 112:2017, čl. 3.3, 4.4, 5.9","C390:22, čl. 5, 7.1.2, 7.1.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Próba nagrzewania Točivé elektrické stroje Zkouška oteplení IEC 60034-1 ed. 14, čl. 8; IEEE Std 112:2017, čl. 3.3, 4.4, 5.9; C390:22, čl. 5, 7.1.2, 7.1.3 Maszyny elektryczne wirujace Proba nagrzewania Tocive elektricke stroje Zkouska otepleni IEC 60034-1 ed. 14, cl. 8; IEEE Std 112:2017, cl. 3.3, 4.4, 5.9; C390:22, cl. 5, 7.1.2, 7.1.3","search_en":"Rotating electrical machines Temperature-rise test IEC 60034-1 ed. 14, čl. 8; IEEE Std 112:2017, čl. 3.3, 4.4, 5.9; C390:22, čl. 5, 7.1.2, 7.1.3","search_zh":"旋转电机 温升试验 IEC 60034-1 ed. 14, čl. 8; IEEE Std 112:2017, čl. 3.3, 4.4, 5.9; C390:22, čl. 5, 7.1.2, 7.1.3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6c3216480185dc8d438613e2","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"5","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Pomiar charakterystyk obciążeniowych","methodology_en":"Measurement of loading characteristics","methodology_zh":"负载特性测量","methodology_cs":"Měření zatěžovacích charakteristik","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyk obciążeniowych","reference":"IEC 60034-2-1 ed. 3, čl. 6.1.3.2.3; IEEE Std 112:2017, čl. 3.3, 5.7; C390:22, art. 5, 7.1.2, 7.1.4","norm_bases":["IEC 60034-2-1 ed. 3, čl. 6.1.3.2.3","IEEE Std 112:2017, čl. 3.3, 5.7","C390:22, art. 5, 7.1.2, 7.1.4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Pomiar charakterystyk obciążeniowych Točivé elektrické stroje Měření zatěžovacích charakteristik IEC 60034-2-1 ed. 3, čl. 6.1.3.2.3; IEEE Std 112:2017, čl. 3.3, 5.7; C390:22, art. 5, 7.1.2, 7.1.4 Maszyny elektryczne wirujace Pomiar charakterystyk obciazeniowych Tocive elektricke stroje Mereni zatezovacich charakteristik IEC 60034-2-1 ed. 3, cl. 6.1.3.2.3; IEEE Std 112:2017, cl. 3.3, 5.7; C390:22, art. 5, 7.1.2, 7.1.4","search_en":"Rotating electrical machines Measurement of loading characteristics IEC 60034-2-1 ed. 3, čl. 6.1.3.2.3; IEEE Std 112:2017, čl. 3.3, 5.7; C390:22, art. 5, 7.1.2, 7.1.4","search_zh":"旋转电机 负载特性测量 IEC 60034-2-1 ed. 3, čl. 6.1.3.2.3; IEEE Std 112:2017, čl. 3.3, 5.7; C390:22, art. 5, 7.1.2, 7.1.4","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"00b6db98e24d1944fbd7c85e","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"6","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Pomiar charakterystyki biegu jałowego i strat jałowych","methodology_en":"Measurement of no-load curve and no-load loss","methodology_zh":"空载特性和空载损耗测量","methodology_cs":"Měření charakteristiky naprázdno a ztrát naprázdno","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyki biegu jałowego i strat jałowych","reference":"IEC 60034-2-1 ed. 3, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE Std 112:2017, čl. 3.3, 5.6; C390:22, art. 5, 7.1.2, 7.1.7","norm_bases":["IEC 60034-2-1 ed. 3, čl. 6.1.3.2.4, 6.1.3.2.5","IEEE Std 112:2017, čl. 3.3, 5.6","C390:22, art. 5, 7.1.2, 7.1.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Pomiar charakterystyki biegu jałowego i strat jałowych Točivé elektrické stroje Měření charakteristiky naprázdno a ztrát naprázdno IEC 60034-2-1 ed. 3, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE Std 112:2017, čl. 3.3, 5.6; C390:22, art. 5, 7.1.2, 7.1.7 Maszyny elektryczne wirujace Pomiar charakterystyki biegu jalowego i strat jalowych Tocive elektricke stroje Mereni charakteristiky naprazdno a ztrat naprazdno IEC 60034-2-1 ed. 3, cl. 6.1.3.2.4, 6.1.3.2.5; IEEE Std 112:2017, cl. 3.3, 5.6; C390:22, art. 5, 7.1.2, 7.1.7","search_en":"Rotating electrical machines Measurement of no-load curve and no-load loss IEC 60034-2-1 ed. 3, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE Std 112:2017, čl. 3.3, 5.6; C390:22, art. 5, 7.1.2, 7.1.7","search_zh":"旋转电机 空载特性和空载损耗测量 IEC 60034-2-1 ed. 3, čl. 6.1.3.2.4, 6.1.3.2.5; IEEE Std 112:2017, čl. 3.3, 5.6; C390:22, art. 5, 7.1.2, 7.1.7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc9d10a8f3b33bd9ac6e73ae","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"7","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Wyznaczanie sprawności","methodology_en":"Determination of efficiency","methodology_zh":"效率测定","methodology_cs":"Určení účinnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie sprawności","reference":"IEC 60034-2-1 ed. 3, čl. 6.1.2, 6.1.3; IEEE Std 112:2017, čl. 3.3, 6.3, 6.4; C390:22, čl. 5, 7.1.2, 7.2","norm_bases":["IEC 60034-2-1 ed. 3, čl. 6.1.2, 6.1.3","IEEE Std 112:2017, čl. 3.3, 6.3, 6.4","C390:22, čl. 5, 7.1.2, 7.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Wyznaczanie sprawności Točivé elektrické stroje Určení účinnosti IEC 60034-2-1 ed. 3, čl. 6.1.2, 6.1.3; IEEE Std 112:2017, čl. 3.3, 6.3, 6.4; C390:22, čl. 5, 7.1.2, 7.2 Maszyny elektryczne wirujace Wyznaczanie sprawnosci Tocive elektricke stroje Urceni ucinnosti IEC 60034-2-1 ed. 3, cl. 6.1.2, 6.1.3; IEEE Std 112:2017, cl. 3.3, 6.3, 6.4; C390:22, cl. 5, 7.1.2, 7.2","search_en":"Rotating electrical machines Determination of efficiency IEC 60034-2-1 ed. 3, čl. 6.1.2, 6.1.3; IEEE Std 112:2017, čl. 3.3, 6.3, 6.4; C390:22, čl. 5, 7.1.2, 7.2","search_zh":"旋转电机 效率测定 IEC 60034-2-1 ed. 3, čl. 6.1.2, 6.1.3; IEEE Std 112:2017, čl. 3.3, 6.3, 6.4; C390:22, čl. 5, 7.1.2, 7.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ebc2b307a559f9c2492838f","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"8","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Pomiar charakterystyki zwarcia","methodology_en":"Measurement of short-circuit curve","methodology_zh":"短路特性测量","methodology_cs":"Měření charakteristiky nakrátko","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyki zwarcia","reference":"IEC 60034-12 ed. 4, čl. 12.1, 12.4; IEEE Std 112:2017, čl. 3.3, 7.2","norm_bases":["IEC 60034-12 ed. 4, čl. 12.1, 12.4","IEEE Std 112:2017, čl. 3.3, 7.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Pomiar charakterystyki zwarcia Točivé elektrické stroje Měření charakteristiky nakrátko IEC 60034-12 ed. 4, čl. 12.1, 12.4; IEEE Std 112:2017, čl. 3.3, 7.2 Maszyny elektryczne wirujace Pomiar charakterystyki zwarcia Tocive elektricke stroje Mereni charakteristiky nakratko IEC 60034-12 ed. 4, cl. 12.1, 12.4; IEEE Std 112:2017, cl. 3.3, 7.2","search_en":"Rotating electrical machines Measurement of short-circuit curve IEC 60034-12 ed. 4, čl. 12.1, 12.4; IEEE Std 112:2017, čl. 3.3, 7.2","search_zh":"旋转电机 短路特性测量 IEC 60034-12 ed. 4, čl. 12.1, 12.4; IEEE Std 112:2017, čl. 3.3, 7.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a57d75bb591f1459c6dccf71","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"9","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Pomiar charakterystyki momentu","methodology_en":"Measurement of torque curve","methodology_zh":"转矩特性测量","methodology_cs":"Měření momentové charakteristiky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyki momentu","reference":"IEC 60034-12 ed. 4, čl. 12.2, 12.3, 12.4; IEEE Std 112:2017, čl. 3.3, 7.3.2.5, 7.3.3","norm_bases":["IEC 60034-12 ed. 4, čl. 12.2, 12.3, 12.4","IEEE Std 112:2017, čl. 3.3, 7.3.2.5, 7.3.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Pomiar charakterystyki momentu Točivé elektrické stroje Měření momentové charakteristiky IEC 60034-12 ed. 4, čl. 12.2, 12.3, 12.4; IEEE Std 112:2017, čl. 3.3, 7.3.2.5, 7.3.3 Maszyny elektryczne wirujace Pomiar charakterystyki momentu Tocive elektricke stroje Mereni momentove charakteristiky IEC 60034-12 ed. 4, cl. 12.2, 12.3, 12.4; IEEE Std 112:2017, cl. 3.3, 7.3.2.5, 7.3.3","search_en":"Rotating electrical machines Measurement of torque curve IEC 60034-12 ed. 4, čl. 12.2, 12.3, 12.4; IEEE Std 112:2017, čl. 3.3, 7.3.2.5, 7.3.3","search_zh":"旋转电机 转矩特性测量 IEC 60034-12 ed. 4, čl. 12.2, 12.3, 12.4; IEEE Std 112:2017, čl. 3.3, 7.3.2.5, 7.3.3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"03b2b8b3b4a14da8c0c04030","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"10","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Próba dorywczego przeciążenia prądowego","methodology_en":"Occasional excess current test","methodology_zh":"偶然过电流试验","methodology_cs":"Zkouška nahodilého proudového přetížení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba dorywczego przeciążenia prądowego","reference":"IEC 60034-1 ed. 14, čl. 9.3","norm_bases":["IEC 60034-1 ed. 14, čl. 9.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Próba dorywczego przeciążenia prądowego Točivé elektrické stroje Zkouška nahodilého proudového přetížení IEC 60034-1 ed. 14, čl. 9.3 Maszyny elektryczne wirujace Proba dorywczego przeciazenia pradowego Tocive elektricke stroje Zkouska nahodileho proudoveho pretizeni IEC 60034-1 ed. 14, cl. 9.3","search_en":"Rotating electrical machines Occasional excess current test IEC 60034-1 ed. 14, čl. 9.3","search_zh":"旋转电机 偶然过电流试验 IEC 60034-1 ed. 14, čl. 9.3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b5da07a6a9d343244ca9b83","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"11","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Próba krótkotrwałego przeciążenia momentem","methodology_en":"Test of momentary excess torque for motors","methodology_zh":"电动机短时过转矩试验","methodology_cs":"Zkouška krátkodobého momentového přetížení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba krótkotrwałego przeciążenia momentem","reference":"IEC 60034-1 ed. 14, čl. 9.4","norm_bases":["IEC 60034-1 ed. 14, čl. 9.4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Próba krótkotrwałego przeciążenia momentem Točivé elektrické stroje Zkouška krátkodobého momentového přetížení IEC 60034-1 ed. 14, čl. 9.4 Maszyny elektryczne wirujace Proba krotkotrwalego przeciazenia momentem Tocive elektricke stroje Zkouska kratkodobeho momentoveho pretizeni IEC 60034-1 ed. 14, cl. 9.4","search_en":"Rotating electrical machines Test of momentary excess torque for motors IEC 60034-1 ed. 14, čl. 9.4","search_zh":"旋转电机 电动机短时过转矩试验 IEC 60034-1 ed. 14, čl. 9.4","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"df9730787f61f63eb9c73534","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"12","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Próba zwiększonej prędkości obrotowej","methodology_en":"Overspeed test","methodology_zh":"超速试验","methodology_cs":"Zkouška zvýšenými otáčkami","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba zwiększonej prędkości obrotowej","reference":"IEC 60034-1 ed. 14, čl. 9.7","norm_bases":["IEC 60034-1 ed. 14, čl. 9.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Próba zwiększonej prędkości obrotowej Točivé elektrické stroje Zkouška zvýšenými otáčkami IEC 60034-1 ed. 14, čl. 9.7 Maszyny elektryczne wirujace Proba zwiekszonej predkosci obrotowej Tocive elektricke stroje Zkouska zvysenymi otackami IEC 60034-1 ed. 14, cl. 9.7","search_en":"Rotating electrical machines Overspeed test IEC 60034-1 ed. 14, čl. 9.7","search_zh":"旋转电机 超速试验 IEC 60034-1 ed. 14, čl. 9.7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fa0791e517cdf29767a71a8","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"13","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Wyznaczanie sprawności silnika zasilanego z przemiennika częstotliwości","methodology_en":"Determination of the efficiency of a converter-fed motor","methodology_zh":"变频器供电电动机效率测定","methodology_cs":"Určení účinnosti motoru napájeného z frekvenčního měniče","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie sprawności silnika zasilanego z przemiennika częstotliwości","reference":"IEC 60034-2-3 ed. 2, čl. 6.2","norm_bases":["IEC 60034-2-3 ed. 2, čl. 6.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Wyznaczanie sprawności silnika zasilanego z przemiennika częstotliwości Točivé elektrické stroje Určení účinnosti motoru napájeného z frekvenčního měniče IEC 60034-2-3 ed. 2, čl. 6.2 Maszyny elektryczne wirujace Wyznaczanie sprawnosci silnika zasilanego z przemiennika czestotliwosci Tocive elektricke stroje Urceni ucinnosti motoru napajeneho z frekvencniho menice IEC 60034-2-3 ed. 2, cl. 6.2","search_en":"Rotating electrical machines Determination of the efficiency of a converter-fed motor IEC 60034-2-3 ed. 2, čl. 6.2","search_zh":"旋转电机 变频器供电电动机效率测定 IEC 60034-2-3 ed. 2, čl. 6.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0171a4b3b5f3631748958267","lab_id":"69ad52a4de79e566650fd568","country":"CZ","accr_number":"1728","accr_body":"ČIA","row_label":"14","test_object":"Maszyny elektryczne wirujące","test_object_en":"Rotating electrical machines","test_object_zh":"旋转电机","test_object_cs":"Točivé elektrické stroje","methodology":"Sprawdzenie temperatury wywołanej wolnozmiennym przeciążeniem cieplnym","methodology_en":"Verification of temperature due to the thermal overloads with slow variation","methodology_zh":"缓变热过载引起的温度验证","methodology_cs":"Ověření teploty způsobené tepelným přetížením s pomalou změnou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Sprawdzenie temperatury wywołanej wolnozmiennym przeciążeniem cieplnym","reference":"IEC 60034-11 ed. 3, čl. 8.2","norm_bases":["IEC 60034-11 ed. 3, čl. 8.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny elektryczne wirujące Sprawdzenie temperatury wywołanej wolnozmiennym przeciążeniem cieplnym Točivé elektrické stroje Ověření teploty způsobené tepelným přetížením s pomalou změnou IEC 60034-11 ed. 3, čl. 8.2 Maszyny elektryczne wirujace Sprawdzenie temperatury wywolanej wolnozmiennym przeciazeniem cieplnym Tocive elektricke stroje Overeni teploty zpusobene tepelnym pretizenim s pomalou zmenou IEC 60034-11 ed. 3, cl. 8.2","search_en":"Rotating electrical machines Verification of temperature due to the thermal overloads with slow variation IEC 60034-11 ed. 3, čl. 8.2","search_zh":"旋转电机 缓变热过载引起的温度验证 IEC 60034-11 ed. 3, čl. 8.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}