{"lab":{"_id":"69ad52a4de79e566650fd55e","accr_number":"1721","country":"CZ","accr_body":"ČIA","address":"K Mlýnu 892/34, 181 00 Praha 8","categories":["other"],"city":"Praha 8","imported_at":"2026-03-08T10:42:44.590Z","methods_count":2,"name":"NUVIA Dosimetry, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1721_575_2025_CS.pdf","1721_575_2025_EN.pdf"],"scope_summary":"Badania w zakresie dozymetrii indywidualnej narażenia zewnętrznego","search_text":"nuvia dosimetry, s.r.o. k mlýnu 892/34, 181 00 praha 8 automotive","status":"active","updated_at":"2026-03-08T14:52:15.278Z","valid_from":"","valid_until":"11-11-2030","website":"www.nuviadosimetry.com","parsed_at":"2026-09-28T12:00:00.000Z","location":{"type":"Point","coordinates":[14.4378,50.0755]},"email_confidence":"low","email_mx":true,"email_source":"https://www.nuviadosimetry.com","needs_review":true,"review_reason":"e-mail ze strony (domena inna niż WWW) — zweryfikuj","map_coord":[50.143818,14.429987],"map_geo":"nominatim-street","certificate_date":"11.11.2025","certificate_no":"575/2025","certificate_replaces":"550/2024 z 14.10.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania w zakresie dozymetrii indywidualnej narażenia zewnętrznego","en":"Testing in the field of personal dosimetry for external radiation","zh":"外照射个人剂量监测领域的检测","cs":"Zkoušení v oblasti osobní dozimetrie pro zevní ozáření"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Dozymetrii Indywidualnej","lab_division_cs":"Laboratoř osobní dozimetrie","lab_division_en":"Personal Dosimetry Laboratory","lab_division_zh":"个人剂量实验室","lab_locations":[{"code":null,"name":"NUVIA Dosimetry, s.r.o.","street":"K Mlýnu 892/34","postal_code":"181 00","city":"Praha 8","is_hq":true,"address":"K Mlýnu 892/34, 181 00 Praha 8","site":"18100|kmlýnu892/34"},{"code":null,"name":"Laboratorium Dozymetrii Indywidualnej","street":"K Mlýnu 892/34","postal_code":"181 00","city":"Praha 8","is_hq":false,"address":"K Mlýnu 892/34, 181 00 Praha 8","site":"18100|kmlýnu892/34"}],"lab_locations_en":[{"code":null,"name":"NUVIA Dosimetry, s.r.o.","street":"K Mlýnu 892/34","postal_code":"181 00","city":"Praha 8","is_hq":true,"address":"K Mlýnu 892/34, 181 00 Praha 8","site":"18100|kmlýnu892/34"},{"code":null,"name":"Personal Dosimetry Laboratory","street":"K Mlýnu 892/34","postal_code":"181 00","city":"Praha 8","is_hq":false,"address":"K Mlýnu 892/34, 181 00 Praha 8","site":"18100|kmlýnu892/34"}],"lab_locations_zh":[{"code":null,"name":"NUVIA Dosimetry, s.r.o.","street":"K Mlýnu 892/34","postal_code":"181 00","city":"Praha 8","is_hq":true,"address":"K Mlýnu 892/34, 181 00 Praha 8","site":"18100|kmlýnu892/34"},{"code":null,"name":"个人剂量实验室","street":"K Mlýnu 892/34","postal_code":"181 00","city":"Praha 8","is_hq":false,"address":"K Mlýnu 892/34, 181 00 Praha 8","site":"18100|kmlýnu892/34"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"SVP","pl":"standardowa procedura oceny","en":"Standard Assessment Procedure","zh":"标准评估程序","cs":"standardní vyhodnocovací postup"},{"abbr":"Hp","pl":"indywidualny równoważnik dawki","en":"Personal Dose Equivalent","zh":"个人剂量当量","cs":"osobní dávkový ekvivalent"},{"abbr":"E","pl":"dawka skuteczna","en":"Effective Dose","zh":"有效剂量","cs":"efektivní dávka"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"42ee2c9c88757450e25f38d6f3053eb23e3008ea16603d70bfaab1a7e0ea3024","source_pdf_url":"https://www.cai.cz/OA/pdf/575_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/575_2025_EN.pdf"},"methods":[{"_id":"8a7720df04b9cc821aad5fde","lab_id":"69ad52a4de79e566650fd55e","country":"CZ","accr_number":"1721","accr_body":"ČIA","row_label":"1","test_object":"Dawkomierz filmowy indywidualny NUVIA","test_object_en":"NUVIA personal film dosimeter","test_object_zh":"NUVIA个人胶片剂量计","test_object_cs":"Osobní filmový dozimetr NUVIA","methodology":"Oznaczanie indywidualnych równoważników dawki Hp(10), Hp(0,07) w polach promieniowania fotonowego i elektronowego","methodology_en":"Determination of personal dose equivalents Hp(10), Hp(0.07) in photon and electron radiation fields","methodology_zh":"光子和电子辐射场中个人剂量当量Hp(10)、Hp(0.07)测定","methodology_cs":"Stanovení osobních dávkových ekvivalentů Hp(10), Hp(0,07) v polích fotonového a elektronového záření","parameters":[{"name":"Hp(10)","range":""},{"name":"Hp(0,07)","range":""}],"parameters_en":[{"name":"Hp(10)","range":""},{"name":"Hp(0.07)","range":""}],"parameters_zh":[{"name":"Hp(10)个人剂量当量","range":""},{"name":"Hp(0.07)个人剂量当量","range":""}],"parameters_cs":[{"name":"Hp(10)","range":""},{"name":"Hp(0,07)","range":""}],"technique":"Dozymetria filmowa","technique_en":"Film dosimetry method","technique_zh":"胶片剂量测定法","technique_cs":"metodou filmové dozimetrie","techniques":["Dozymetria filmowa"],"techniques_en":["Film dosimetry method"],"techniques_zh":["胶片剂量测定法"],"techniques_cs":["metodou filmové dozimetrie"],"computed":["Dawka skuteczna E (z obliczeń)"],"computed_en":["Determination of effective dose E by calculation"],"computed_zh":["有效剂量E（计算）"],"computed_cs":["Stanovení efektivní dávky E výpočtem"],"activity":"Oznaczanie indywidualnych równoważników dawki Hp(10), Hp(0,07) w polach promieniowania fotonowego i elektronowego\nZakres:\nHp(10)\nHp(0,07)\nDozymetria filmowa","reference":"SVP-1","norm_bases":["SVP-1"],"lab_section":"Laboratorium Dozymetrii Indywidualnej","lab_section_en":"Personal Dosimetry Laboratory","lab_section_zh":"个人剂量实验室","lab_section_cs":"Laboratoř osobní dozimetrie","lab_address":"K Mlýnu 892/34, 181 00 Praha 8","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dawkomierz filmowy indywidualny NUVIA Oznaczanie indywidualnych równoważników dawki Hp(10), Hp(0,07) w polach promieniowania fotonowego i elektronowego Dozymetria filmowa Hp(10)  Hp(0,07)  Dawka skuteczna E (z obliczeń) Osobní filmový dozimetr NUVIA Stanovení osobních dávkových ekvivalentů Hp(10), Hp(0,07) v polích fotonového a elektronového záření metodou filmové dozimetrie Hp(10)  Hp(0,07)  Stanovení efektivní dávky E výpočtem SVP-1 Dawkomierz filmowy indywidualny NUVIA Oznaczanie indywidualnych rownowaznikow dawki Hp(10), Hp(0,07) w polach promieniowania fotonowego i elektronowego Dozymetria filmowa Hp(10)  Hp(0,07)  Dawka skuteczna E (z obliczen) Osobni filmovy dozimetr NUVIA Stanoveni osobnich davkovych ekvivalentu Hp(10), Hp(0,07) v polich fotonoveho a elektronoveho zareni metodou filmove dozimetrie Hp(10)  Hp(0,07)  Stanoveni efektivni davky E vypoctem SVP-1","search_en":"NUVIA personal film dosimeter Determination of personal dose equivalents Hp(10), Hp(0.07) in photon and electron radiation fields Film dosimetry method Hp(10)  Hp(0.07)  Determination of effective dose E by calculation SVP-1","search_zh":"NUVIA个人胶片剂量计 光子和电子辐射场中个人剂量当量Hp(10)、Hp(0.07)测定 胶片剂量测定法 Hp(10)个人剂量当量  Hp(0.07)个人剂量当量  有效剂量E（计算） SVP-1","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41018851f9fec20eb6730792","lab_id":"69ad52a4de79e566650fd55e","country":"CZ","accr_number":"1721","accr_body":"ČIA","row_label":"2","test_object":"Dawkomierz neutronowy całego ciała firmy Chiyoda Technol Corporation","test_object_en":"Whole-body neutron dosimeter from Chiyoda Technol Corporation","test_object_zh":"Chiyoda Technol Corporation全身中子剂量计","test_object_cs":"Celotělový neutronový dozimetr od společnosti Chiyoda Technol Corporation","methodology":"Oznaczanie indywidualnego równoważnika dawki Hp(10) w polach promieniowania neutronowego","methodology_en":"Determination of personal dose equivalent Hp(10) in neutron radiation fields","methodology_zh":"中子辐射场中个人剂量当量Hp(10)测定","methodology_cs":"Stanovení osobního dávkového ekvivalentu Hp(10) v polích neutronového záření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["Dawka skuteczna E (z obliczeń)"],"computed_en":["Determination of effective dose E by calculation"],"computed_zh":["有效剂量E（计算）"],"computed_cs":["Stanovení efektivní dávky E výpočtem"],"activity":"Oznaczanie indywidualnego równoważnika dawki Hp(10) w polach promieniowania neutronowego","reference":"SVP-5","norm_bases":["SVP-5"],"lab_section":"Laboratorium Dozymetrii Indywidualnej","lab_section_en":"Personal Dosimetry Laboratory","lab_section_zh":"个人剂量实验室","lab_section_cs":"Laboratoř osobní dozimetrie","lab_address":"K Mlýnu 892/34, 181 00 Praha 8","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dawkomierz neutronowy całego ciała firmy Chiyoda Technol Corporation Oznaczanie indywidualnego równoważnika dawki Hp(10) w polach promieniowania neutronowego Dawka skuteczna E (z obliczeń) Celotělový neutronový dozimetr od společnosti Chiyoda Technol Corporation Stanovení osobního dávkového ekvivalentu Hp(10) v polích neutronového záření Stanovení efektivní dávky E výpočtem SVP-5 Dawkomierz neutronowy calego ciala firmy Chiyoda Technol Corporation Oznaczanie indywidualnego rownowaznika dawki Hp(10) w polach promieniowania neutronowego Dawka skuteczna E (z obliczen) Celotelovy neutronovy dozimetr od spolecnosti Chiyoda Technol Corporation Stanoveni osobniho davkoveho ekvivalentu Hp(10) v polich neutronoveho zareni Stanoveni efektivni davky E vypoctem SVP-5","search_en":"Whole-body neutron dosimeter from Chiyoda Technol Corporation Determination of personal dose equivalent Hp(10) in neutron radiation fields Determination of effective dose E by calculation SVP-5","search_zh":"Chiyoda Technol Corporation全身中子剂量计 中子辐射场中个人剂量当量Hp(10)测定 有效剂量E（计算） SVP-5","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}