{"lab":{"_id":"69ad52a4de79e566650fd538","accr_number":"1689","country":"CZ","accr_body":"ČIA","address":"Siřejovická 1213, 410 02 Lovosice","categories":["petro"],"city":"Lovosice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":3,"name":"Flexfill s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1689_523_2025_CS.pdf","1689_523_2025_EN.pdf"],"scope_summary":"Pobieranie próbek i oznaczanie gęstości substancji na bazie ciekłych węglowodorów, w tym olejów mineralnych","search_text":"flexfill s.r.o. siřejovická 1213, 410 02 lovosice 1689","status":"active","updated_at":"2026-03-08T14:52:14.846Z","valid_from":"","valid_until":"09-10-2028","website":"www.flexfill.cz","map_coord":[50.50839,14.050025],"map_geo":"nominatim-street","certificate_date":"17.10.2025","certificate_no":"523/2025","certificate_replaces":"107/2025 z 05.03.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek i oznaczanie gęstości substancji na bazie ciekłych węglowodorów, w tym olejów mineralnych","en":"Sampling and determination of density of liquid hydrocarbon-based substances including mineral oils","zh":"液态烃类物质（包括矿物油）的取样及密度测定","cs":"Odběr a stanovení hustoty látek na bázi kapalných uhlovodíků včetně minerálních olejů"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"I_QM","pl":"standardowa procedura operacyjna – instrukcja","en":"standard operating procedure – instruction","zh":"标准操作程序 – 作业指导书","cs":"standardní operační postup – instrukce"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"5fdbb5cf0dcbd440d2ba77468adb40654d768147957a84fa8d56503d609b57dd","source_pdf_url":"https://www.cai.cz/OA/pdf/523_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"e2be996ad6a1f3d367907616","lab_id":"69ad52a4de79e566650fd538","country":"CZ","accr_number":"1689","accr_body":"ČIA","row_label":"1","test_object":"Substancje na bazie ciekłych węglowodorów, w tym oleje mineralne, o gęstości do 1100 kg/m3","test_object_en":"Liquid hydrocarbon-based substances including mineral oils with density up to 1100 kg/m3","test_object_zh":"密度不超过1100 kg/m3的液态烃类物质（包括矿物油）","test_object_cs":"Látky na bázi kapalných uhlovodíků včetně minerálních olejů s hustotou do 1100 kg/m3","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení hustoty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda oscylacyjnej rurki U","technique_en":"Oscillating U-tube method","technique_zh":"振荡U形管法","technique_cs":"metodou oscilační U trubice","techniques":["Metoda oscylacyjnej rurki U"],"techniques_en":["Oscillating U-tube method"],"techniques_zh":["振荡U形管法"],"techniques_cs":["metodou oscilační U trubice"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości\nMetoda oscylacyjnej rurki U","reference":"I_QM_49 (ČSN EN ISO 12185)","norm_bases":["I_QM_49","ČSN EN ISO 12185"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Substancje na bazie ciekłych węglowodorów, w tym oleje mineralne, o gęstości do 1100 kg/m3 Oznaczanie gęstości Metoda oscylacyjnej rurki U Látky na bázi kapalných uhlovodíků včetně minerálních olejů s hustotou do 1100 kg/m3 Stanovení hustoty metodou oscilační U trubice I_QM_49 (ČSN EN ISO 12185) Substancje na bazie cieklych weglowodorow, w tym oleje mineralne, o gestosci do 1100 kg/m3 Oznaczanie gestosci Metoda oscylacyjnej rurki U Latky na bazi kapalnych uhlovodiku vcetne mineralnich oleju s hustotou do 1100 kg/m3 Stanoveni hustoty metodou oscilacni U trubice I_QM_49 (CSN EN ISO 12185)","search_en":"Liquid hydrocarbon-based substances including mineral oils with density up to 1100 kg/m3 Determination of density Oscillating U-tube method I_QM_49 (ČSN EN ISO 12185)","search_zh":"密度不超过1100 kg/m3的液态烃类物质（包括矿物油） 密度测定 振荡U形管法 I_QM_49 (ČSN EN ISO 12185)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f159ca6b55e23cd42f887302","lab_id":"69ad52a4de79e566650fd538","country":"CZ","accr_number":"1689","accr_body":"ČIA","row_label":"2","test_object":"Substancje na bazie ciekłych węglowodorów, w tym oleje mineralne, o gęstości powyżej 1100 kg/m3","test_object_en":"Liquid hydrocarbon-based substances including mineral oils with density above 1100 kg/m3","test_object_zh":"密度超过1100 kg/m3的液态烃类物质（包括矿物油）","test_object_cs":"Látky na bázi kapalných uhlovodíků včetně minerálních olejů s hustotou nad 1100 kg/m3","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení hustoty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda oscylacyjnej rurki U","technique_en":"Oscillating U-tube method","technique_zh":"振荡U形管法","technique_cs":"metodou oscilační U trubice","techniques":["Metoda oscylacyjnej rurki U"],"techniques_en":["Oscillating U-tube method"],"techniques_zh":["振荡U形管法"],"techniques_cs":["metodou oscilační U trubice"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości\nMetoda oscylacyjnej rurki U","reference":"I_QM_56 (ASTM D4052)","norm_bases":["I_QM_56","ASTM D4052"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Substancje na bazie ciekłych węglowodorów, w tym oleje mineralne, o gęstości powyżej 1100 kg/m3 Oznaczanie gęstości Metoda oscylacyjnej rurki U Látky na bázi kapalných uhlovodíků včetně minerálních olejů s hustotou nad 1100 kg/m3 Stanovení hustoty metodou oscilační U trubice I_QM_56 (ASTM D4052) Substancje na bazie cieklych weglowodorow, w tym oleje mineralne, o gestosci powyzej 1100 kg/m3 Oznaczanie gestosci Metoda oscylacyjnej rurki U Latky na bazi kapalnych uhlovodiku vcetne mineralnich oleju s hustotou nad 1100 kg/m3 Stanoveni hustoty metodou oscilacni U trubice I_QM_56 (ASTM D4052)","search_en":"Liquid hydrocarbon-based substances including mineral oils with density above 1100 kg/m3 Determination of density Oscillating U-tube method I_QM_56 (ASTM D4052)","search_zh":"密度超过1100 kg/m3的液态烃类物质（包括矿物油） 密度测定 振荡U形管法 I_QM_56 (ASTM D4052)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"963be59355581347e8fb205e","lab_id":"69ad52a4de79e566650fd538","country":"CZ","accr_number":"1689","accr_body":"ČIA","row_label":"1","test_object":"Substancje na bazie ciekłych węglowodorów, w tym oleje mineralne","test_object_en":"Liquid hydrocarbon-based substances including mineral oils","test_object_zh":"液态烃类物质（包括矿物油）","test_object_cs":"Látky na bázi kapalných uhlovodíků včetně minerálních olejů","methodology":"Pobieranie próbek","methodology_en":"Sampling","methodology_zh":"取样","methodology_cs":"Odběr vzorků","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda obciążonego kosza z próbnikiem i metoda rurki do pobierania próbek","technique_en":"Weighted sampling cage with bottle method and sampling tube (thief) method","technique_zh":"带样瓶加重笼法和取样管法","technique_cs":"metodou zatížené klece se vzorkovnicí a metodou vzorkovací trubice","techniques":["Metoda obciążonego kosza z próbnikiem i metoda rurki do pobierania próbek"],"techniques_en":["Weighted sampling cage with bottle method and sampling tube (thief) method"],"techniques_zh":["带样瓶加重笼法和取样管法"],"techniques_cs":["metodou zatížené klece se vzorkovnicí a metodou vzorkovací trubice"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek\nMetoda obciążonego kosza z próbnikiem i metoda rurki do pobierania próbek","reference":"I_QM_48 (ČSN EN ISO 3170, čl. 5.2.2 a 5.3)","norm_bases":["I_QM_48","ČSN EN ISO 3170, čl. 5.2.2 a 5.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Substancje na bazie ciekłych węglowodorów, w tym oleje mineralne Pobieranie próbek Metoda obciążonego kosza z próbnikiem i metoda rurki do pobierania próbek Látky na bázi kapalných uhlovodíků včetně minerálních olejů Odběr vzorků metodou zatížené klece se vzorkovnicí a metodou vzorkovací trubice I_QM_48 (ČSN EN ISO 3170, čl. 5.2.2 a 5.3) Substancje na bazie cieklych weglowodorow, w tym oleje mineralne Pobieranie probek Metoda obciazonego kosza z probnikiem i metoda rurki do pobierania probek Latky na bazi kapalnych uhlovodiku vcetne mineralnich oleju Odber vzorku metodou zatizene klece se vzorkovnici a metodou vzorkovaci trubice I_QM_48 (CSN EN ISO 3170, cl. 5.2.2 a 5.3)","search_en":"Liquid hydrocarbon-based substances including mineral oils Sampling Weighted sampling cage with bottle method and sampling tube (thief) method I_QM_48 (ČSN EN ISO 3170, čl. 5.2.2 a 5.3)","search_zh":"液态烃类物质（包括矿物油） 取样 带样瓶加重笼法和取样管法 I_QM_48 (ČSN EN ISO 3170, čl. 5.2.2 a 5.3)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}