{"lab":{"_id":"69ad52a4de79e566650fd530","accr_number":"1683","country":"CZ","accr_body":"ČIA","address":"Vratimovská 689/117, Kunčice, 719 00 Ostrava","categories":["materials"],"city":"Ostrava","imported_at":"2026-03-08T10:42:44.590Z","methods_count":2,"name":"NOVÁ HUŤ s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1683_613_2025_CS.pdf","1683_613_2025_EN.pdf"],"scope_summary":"Badania ultradźwiękowe i radiograficzne rur spiralnie spawanych","search_text":"nová huť s.r.o. vratimovská 689/117, kunčice, 719 00 ostrava other","status":"active","updated_at":"2026-03-08T14:52:14.734Z","valid_from":"","valid_until":"30-06-2028","website":"www.novahut.cz","parsed_at":"2026-09-28T12:00:00.000Z","location":{"type":"Point","coordinates":[18.2625,49.8209]},"email_confidence":"high","email_mx":true,"email_source":"https://www.novahut.cz/contact","map_coord":[49.795213,18.306095],"map_geo":"nominatim-street","certificate_date":"25.11.2025","certificate_no":"613/2025","certificate_replaces":"349/2023 z 30.06.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania ultradźwiękowe i radiograficzne rur spiralnie spawanych","en":"Ultrasonic and radiographic testing of spiral welded tubes","zh":"螺旋焊管超声检测和射线检测","cs":"Zkoušení ultrazvukem a zkoušení prozařováním spirálově svařovaných trubek"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium badań nieniszczących (NDT)","lab_division_cs":"NDT zkušebna","lab_division_en":"NDT Testing Laboratory","lab_division_zh":"无损检测实验室","lab_locations":[{"code":null,"name":"NOVÁ HUŤ s.r.o.","street":"Vratimovská 689/117, Kunčice","postal_code":"719 00","city":"Ostrava","is_hq":true,"address":"Vratimovská 689/117, Kunčice, 719 00 Ostrava","site":"71900|vratimovská689/117kunčice"},{"code":null,"name":"Linia SNUP","street":"Vratimovská 689/117","postal_code":"719 00","city":"Ostrava-Kunčice","is_hq":false,"address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","site":"71900|vratimovská689/117"},{"code":null,"name":"Linia RTG","street":"Vratimovská 689/117","postal_code":"719 00","city":"Ostrava-Kunčice","is_hq":false,"address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","site":"71900|vratimovská689/117"}],"lab_locations_en":[{"code":null,"name":"NOVÁ HUŤ s.r.o.","street":"Vratimovská 689/117, Kunčice","postal_code":"719 00","city":"Ostrava","is_hq":true,"address":"Vratimovská 689/117, Kunčice, 719 00 Ostrava","site":"71900|vratimovská689/117kunčice"},{"code":null,"name":"SNUP line","street":"Vratimovská 689/117","postal_code":"719 00","city":"Ostrava-Kunčice","is_hq":false,"address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","site":"71900|vratimovská689/117"},{"code":null,"name":"RTG line","street":"Vratimovská 689/117","postal_code":"719 00","city":"Ostrava-Kunčice","is_hq":false,"address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","site":"71900|vratimovská689/117"}],"lab_locations_zh":[{"code":null,"name":"NOVÁ HUŤ s.r.o.","street":"Vratimovská 689/117, Kunčice","postal_code":"719 00","city":"Ostrava","is_hq":true,"address":"Vratimovská 689/117, Kunčice, 719 00 Ostrava","site":"71900|vratimovská689/117kunčice"},{"code":null,"name":"SNUP生产线","street":"Vratimovská 689/117","postal_code":"719 00","city":"Ostrava-Kunčice","is_hq":false,"address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","site":"71900|vratimovská689/117"},{"code":null,"name":"RTG生产线","street":"Vratimovská 689/117","postal_code":"719 00","city":"Ostrava-Kunčice","is_hq":false,"address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","site":"71900|vratimovská689/117"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"API","pl":"American Petroleum Institute (Amerykański Instytut Naftowy)","en":"American Petroleum Institute","zh":"美国石油学会","cs":"American Petroleum Institute (Americký petrolejářský institut)"},{"abbr":"SEP","pl":"Stahl Eisen Prüfblatt (przepis badawczy dla badań stali)","en":"Stahl Eissen Prüfblatt","zh":"Stahl Eisen Prüfblatt（钢材检验规程）","cs":"Stahl Eissen Prüfblatt (Zkušební předpis pro zkoušení oceli)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"98c316e3e633d0d9109d80be18cbd275e54689a2984c7a466dfe2802b1789146","source_pdf_url":"https://www.cai.cz/OA/pdf/613_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/613_2025_EN.pdf"},"methods":[{"_id":"fcd3237b6e2f6f066ffb0794","lab_id":"69ad52a4de79e566650fd530","country":"CZ","accr_number":"1683","accr_body":"ČIA","row_label":"1","test_object":"Spoina, strefa wpływu ciepła i materiał rodzimy rur spiralnie spawanych","test_object_en":"Weld seam, heat affected zone and coil material of spiral welded tubes","test_object_zh":"螺旋焊管的焊缝、热影响区和母材","test_object_cs":"Svar, tepelně ovlivněná zóna a základní materiál spirálově svařovaných trubek","methodology":"Badanie ultradźwiękowe","methodology_en":"Ultrasonic testing","methodology_zh":"超声检测","methodology_cs":"Zkoušení ultrazvukem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie ultradźwiękowe","reference":"EN ISO 3183; EN ISO 10 893-8; EN ISO 10 893-9; EN ISO 10 893-11; ČSN EN ISO 3183; ČSN EN ISO 10 893-8; ČSN EN ISO 10 893-9; ČSN EN ISO 10 893-11; API 5L; SEP 1916","norm_bases":["EN ISO 3183","EN ISO 10 893-8","EN ISO 10 893-9","EN ISO 10 893-11","ČSN EN ISO 3183","ČSN EN ISO 10 893-8","ČSN EN ISO 10 893-9","ČSN EN ISO 10 893-11","API 5L","SEP 1916"],"lab_section":"Linia SNUP","lab_section_en":"SNUP line","lab_section_zh":"SNUP生产线","lab_section_cs":"SNUP linka","lab_address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Spoina, strefa wpływu ciepła i materiał rodzimy rur spiralnie spawanych Badanie ultradźwiękowe Svar, tepelně ovlivněná zóna a základní materiál spirálově svařovaných trubek Zkoušení ultrazvukem EN ISO 3183; EN ISO 10 893-8; EN ISO 10 893-9; EN ISO 10 893-11; ČSN EN ISO 3183; ČSN EN ISO 10 893-8; ČSN EN ISO 10 893-9; ČSN EN ISO 10 893-11; API 5L; SEP 1916 Spoina, strefa wplywu ciepla i material rodzimy rur spiralnie spawanych Badanie ultradzwiekowe Svar, tepelne ovlivnena zona a zakladni material spiralove svarovanych trubek Zkouseni ultrazvukem EN ISO 3183; EN ISO 10 893-8; EN ISO 10 893-9; EN ISO 10 893-11; CSN EN ISO 3183; CSN EN ISO 10 893-8; CSN EN ISO 10 893-9; CSN EN ISO 10 893-11; API 5L; SEP 1916","search_en":"Weld seam, heat affected zone and coil material of spiral welded tubes Ultrasonic testing EN ISO 3183; EN ISO 10 893-8; EN ISO 10 893-9; EN ISO 10 893-11; ČSN EN ISO 3183; ČSN EN ISO 10 893-8; ČSN EN ISO 10 893-9; ČSN EN ISO 10 893-11; API 5L; SEP 1916","search_zh":"螺旋焊管的焊缝、热影响区和母材 超声检测 EN ISO 3183; EN ISO 10 893-8; EN ISO 10 893-9; EN ISO 10 893-11; ČSN EN ISO 3183; ČSN EN ISO 10 893-8; ČSN EN ISO 10 893-9; ČSN EN ISO 10 893-11; API 5L; SEP 1916","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bab6cee81ac0dd1181d2aacd","lab_id":"69ad52a4de79e566650fd530","country":"CZ","accr_number":"1683","accr_body":"ČIA","row_label":"2","test_object":"Spoina rur spiralnie spawanych","test_object_en":"Weld seam of spiral welded tubes","test_object_zh":"螺旋焊管焊缝","test_object_cs":"Svar spirálově svařovaných trubek","methodology":"Badanie radiograficzne","methodology_en":"Radiographic testing","methodology_zh":"射线检测","methodology_cs":"Zkoušení prozařováním","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie radiograficzne","reference":"EN ISO 3183; EN ISO 10893-7; EN ISO 17636-2; ČSN EN ISO 3183; ČSN EN ISO 10893-7; ČSN EN ISO 17636-2; API 5L; SEP 1916","norm_bases":["EN ISO 3183","EN ISO 10893-7","EN ISO 17636-2","ČSN EN ISO 3183","ČSN EN ISO 10893-7","ČSN EN ISO 17636-2","API 5L","SEP 1916"],"lab_section":"Linia RTG","lab_section_en":"RTG line","lab_section_zh":"RTG生产线","lab_section_cs":"RTG linka","lab_address":"Vratimovská 689/117, 719 00 Ostrava-Kunčice","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Spoina rur spiralnie spawanych Badanie radiograficzne Svar spirálově svařovaných trubek Zkoušení prozařováním EN ISO 3183; EN ISO 10893-7; EN ISO 17636-2; ČSN EN ISO 3183; ČSN EN ISO 10893-7; ČSN EN ISO 17636-2; API 5L; SEP 1916 Spoina rur spiralnie spawanych Badanie radiograficzne Svar spiralove svarovanych trubek Zkouseni prozarovanim EN ISO 3183; EN ISO 10893-7; EN ISO 17636-2; CSN EN ISO 3183; CSN EN ISO 10893-7; CSN EN ISO 17636-2; API 5L; SEP 1916","search_en":"Weld seam of spiral welded tubes Radiographic testing EN ISO 3183; EN ISO 10893-7; EN ISO 17636-2; ČSN EN ISO 3183; ČSN EN ISO 10893-7; ČSN EN ISO 17636-2; API 5L; SEP 1916","search_zh":"螺旋焊管焊缝 射线检测 EN ISO 3183; EN ISO 10893-7; EN ISO 17636-2; ČSN EN ISO 3183; ČSN EN ISO 10893-7; ČSN EN ISO 17636-2; API 5L; SEP 1916","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}