{"lab":{"_id":"69ad52a4de79e566650fd52e","country":"CZ","accr_number":"1682","accr_body":"ČIA","address":"náměstí Míru 50, 679 21 Černá Hora","categories":["metrology"],"city":"Černá Hora","imported_at":"2026-03-08T10:42:44.590Z","methods_count":3,"name":"VF, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1682_173_2023_CS.pdf","1682_173_2023_EN.pdf"],"scope_summary":"Badania w zakresie dozymetrii indywidualnej – oznaczanie indywidualnych równoważników dawki, dawki równoważnej i skutecznej za pomocą dawkomierzy indywidualnych.","search_text":"vf, a.s. náměstí míru 50, 679 21 černá hora 1682","status":"active","updated_at":"2026-03-08T14:52:14.656Z","valid_from":"","valid_until":"11-04-2028","website":"www.dozimetrie.cz","email_confidence":"low","email_mx":true,"email_source":"https://www.dozimetrie.cz","needs_review":true,"review_reason":"e-mail ze strony (domena inna niż WWW) — zweryfikuj","map_coord":[49.412988,16.580598],"map_geo":"nominatim-street","certificate_date":"11.04.2023","certificate_no":"173/2023","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania w zakresie dozymetrii indywidualnej – oznaczanie indywidualnych równoważników dawki, dawki równoważnej i skutecznej za pomocą dawkomierzy indywidualnych.","en":"Testing in the field of personal dosimetry – determination of personal dose equivalent, equivalent and effective dose by personal dosimeters.","zh":"个人剂量学领域的检测——利用个人剂量计测定个人剂量当量、当量剂量和有效剂量。","cs":"Zkoušení v oblasti osobní dozimetrie – stanovení osobních dávkových ekvivalentů, ekvivalentní a efektivní dávky pomocí osobních dozimetrů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Służba dozymetrii indywidualnej","lab_division_cs":"Služba osobní dozimetrie","lab_division_en":"Personal Dosimetry Service","lab_division_zh":"个人剂量监测服务","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"VF 1INT-2328-M01","pl":"Metodyka monitorowania indywidualnego","en":"Personal monitoring methodology","zh":"个人监测方法","cs":"Metodika osobního monitorování"},{"abbr":"OSL","pl":"luminescencja stymulowana optycznie","en":"optically stimulated luminescence","zh":"光释光","cs":"opticky stimulovaná luminiscence"},{"abbr":"TLD","pl":"dozymetria termoluminescencyjna","en":"thermoluminescence dosimetry","zh":"热释光剂量测定","cs":"termoluminiscenční dozimetrie"},{"abbr":"PP","pl":"przepis roboczy (instrukcja)","en":"working regulation","zh":"工作规程","cs":"pracovní předpis"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"aeae562e40d0358c67fb03715f78a4edbfc53d9e9db0b10eb90eb1f8a8e2c797","source_pdf_url":"https://www.cai.cz/OA/pdf/P173_2023_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"36ec9ef70707b474029a9d6a","lab_id":"69ad52a4de79e566650fd52e","country":"CZ","accr_number":"1682","accr_body":"ČIA","row_label":"1","test_object":"Dawkomierz indywidualny OSL InLight®","test_object_en":"Personal dosimeter OSL InLight®","test_object_zh":"个人剂量计 OSL InLight®","test_object_cs":"Osobní dozimetr OSL InLight®","methodology":"Oznaczanie indywidualnych równoważników dawki Hp(10), Hp(0,07)","methodology_en":"Determination of personal dose equivalents Hp(10), Hp(0,07)","methodology_zh":"个人剂量当量Hp(10)、Hp(0,07)的测定","methodology_cs":"Stanovení osobních dávkových ekvivalentů Hp(10), Hp(0,07)","parameters":[{"name":"Hp(10)","range":""},{"name":"Hp(0,07)","range":""}],"parameters_en":[{"name":"Hp(10)","range":""},{"name":"Hp(0,07)","range":""}],"parameters_zh":[{"name":"个人剂量当量 Hp(10)","range":""},{"name":"个人剂量当量 Hp(0,07)","range":""}],"parameters_cs":[{"name":"Hp(10)","range":""},{"name":"Hp(0,07)","range":""}],"technique":"Metoda OSL","technique_en":"OSL method","technique_zh":"OSL法","technique_cs":"metodou OSL","techniques":["Metoda OSL"],"techniques_en":["OSL method"],"techniques_zh":["OSL法"],"techniques_cs":["metodou OSL"],"computed":["Obliczenie dawki skutecznej (efektywnej) E"],"computed_en":["Calculation of effective dose E"],"computed_zh":["有效剂量E的计算"],"computed_cs":["výpočet efektivní dávky E"],"activity":"Oznaczanie indywidualnych równoważników dawki Hp(10), Hp(0,07)\nZakres:\nHp(10)\nHp(0,07)\nMetoda OSL","reference":"PP VF 1INT-2328-T02 (metodika VF 1INT-2328-M01, kap. 2.1; IEC 62387)","norm_bases":["PP VF 1INT-2328-T02","VF 1INT-2328-M01","IEC 62387"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dawkomierz indywidualny OSL InLight® Oznaczanie indywidualnych równoważników dawki Hp(10), Hp(0,07) Metoda OSL Hp(10)  Hp(0,07)  Obliczenie dawki skutecznej (efektywnej) E Osobní dozimetr OSL InLight® Stanovení osobních dávkových ekvivalentů Hp(10), Hp(0,07) metodou OSL Hp(10)  Hp(0,07)  výpočet efektivní dávky E PP VF 1INT-2328-T02 (metodika VF 1INT-2328-M01, kap. 2.1; IEC 62387) Dawkomierz indywidualny OSL InLight® Oznaczanie indywidualnych rownowaznikow dawki Hp(10), Hp(0,07) Metoda OSL Hp(10)  Hp(0,07)  Obliczenie dawki skutecznej (efektywnej) E Osobni dozimetr OSL InLight® Stanoveni osobnich davkovych ekvivalentu Hp(10), Hp(0,07) metodou OSL Hp(10)  Hp(0,07)  vypocet efektivni davky E PP VF 1INT-2328-T02 (metodika VF 1INT-2328-M01, kap. 2.1; IEC 62387)","search_en":"Personal dosimeter OSL InLight® Determination of personal dose equivalents Hp(10), Hp(0,07) OSL method Hp(10)  Hp(0,07)  Calculation of effective dose E PP VF 1INT-2328-T02 (metodika VF 1INT-2328-M01, kap. 2.1; IEC 62387)","search_zh":"个人剂量计 OSL InLight® 个人剂量当量Hp(10)、Hp(0,07)的测定 OSL法 个人剂量当量 Hp(10)  个人剂量当量 Hp(0,07)  有效剂量E的计算 PP VF 1INT-2328-T02 (metodika VF 1INT-2328-M01, kap. 2.1; IEC 62387)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6c122a797f583cce9cfdc591","lab_id":"69ad52a4de79e566650fd52e","country":"CZ","accr_number":"1682","accr_body":"ČIA","row_label":"2","test_object":"Dawkomierz indywidualny Neutrak® 144-J i 144-T","test_object_en":"Personal dosimeter Neutrak® 144-J and 144-T","test_object_zh":"个人剂量计 Neutrak® 144-J 和 144-T","test_object_cs":"Osobní dozimetr Neutrak® 144-J a 144-T","methodology":"Oznaczanie indywidualnego równoważnika dawki Hp(10)","methodology_en":"Determination of personal dose equivalent Hp(10)","methodology_zh":"个人剂量当量Hp(10)的测定","methodology_cs":"Stanovení osobního dávkového ekvivalentu Hp(10)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Dawkomierz śladowy ciała stałego","technique_en":"Solid-state nuclear track dosimeter","technique_zh":"固体径迹剂量计","technique_cs":"stopovým dozimetrem pevné fáze","techniques":["Dawkomierz śladowy ciała stałego"],"techniques_en":["Solid-state nuclear track dosimeter"],"techniques_zh":["固体径迹剂量计"],"techniques_cs":["stopovým dozimetrem pevné fáze"],"computed":["Obliczenie dawki skutecznej (efektywnej) E"],"computed_en":["Calculation of effective dose E"],"computed_zh":["有效剂量E的计算"],"computed_cs":["výpočet efektivní dávky E"],"activity":"Oznaczanie indywidualnego równoważnika dawki Hp(10)\nDawkomierz śladowy ciała stałego","reference":"PP VF 1INT-2328-T04 (metodika VF 1INT-2328-M01, kap. 2.3; ISO 21909)","norm_bases":["PP VF 1INT-2328-T04","VF 1INT-2328-M01","ISO 21909"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Dawkomierz indywidualny Neutrak® 144-J i 144-T Oznaczanie indywidualnego równoważnika dawki Hp(10) Dawkomierz śladowy ciała stałego Obliczenie dawki skutecznej (efektywnej) E Osobní dozimetr Neutrak® 144-J a 144-T Stanovení osobního dávkového ekvivalentu Hp(10) stopovým dozimetrem pevné fáze výpočet efektivní dávky E PP VF 1INT-2328-T04 (metodika VF 1INT-2328-M01, kap. 2.3; ISO 21909) Dawkomierz indywidualny Neutrak® 144-J i 144-T Oznaczanie indywidualnego rownowaznika dawki Hp(10) Dawkomierz sladowy ciala stalego Obliczenie dawki skutecznej (efektywnej) E Osobni dozimetr Neutrak® 144-J a 144-T Stanoveni osobniho davkoveho ekvivalentu Hp(10) stopovym dozimetrem pevne faze vypocet efektivni davky E PP VF 1INT-2328-T04 (metodika VF 1INT-2328-M01, kap. 2.3; ISO 21909)","search_en":"Personal dosimeter Neutrak® 144-J and 144-T Determination of personal dose equivalent Hp(10) Solid-state nuclear track dosimeter Calculation of effective dose E PP VF 1INT-2328-T04 (metodika VF 1INT-2328-M01, kap. 2.3; ISO 21909)","search_zh":"个人剂量计 Neutrak® 144-J 和 144-T 个人剂量当量Hp(10)的测定 固体径迹剂量计 有效剂量E的计算 PP VF 1INT-2328-T04 (metodika VF 1INT-2328-M01, kap. 2.3; ISO 21909)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef81b3cfc92a1f15b2df6237","lab_id":"69ad52a4de79e566650fd52e","country":"CZ","accr_number":"1682","accr_body":"ČIA","row_label":"3","test_object":"Termoluminescencyjny dawkomierz indywidualny na kończyny","test_object_en":"Thermoluminescent personal extremity dosimeter","test_object_zh":"四肢用热释光个人剂量计","test_object_cs":"Termoluminiscenční osobní dozimetr pro končetiny","methodology":"Oznaczanie indywidualnego równoważnika dawki Hp(0,07)","methodology_en":"Determination of personal dose equivalent Hp(0,07)","methodology_zh":"个人剂量当量Hp(0,07)的测定","methodology_cs":"Stanovení osobního dávkového ekvivalentu Hp(0,07)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda TLD","technique_en":"TLD method","technique_zh":"TLD法","technique_cs":"metodou TLD","techniques":["Metoda TLD"],"techniques_en":["TLD method"],"techniques_zh":["TLD法"],"techniques_cs":["metodou TLD"],"computed":["Obliczenie dawki równoważnej HT"],"computed_en":["Calculation of equivalent dose HT"],"computed_zh":["当量剂量HT的计算"],"computed_cs":["výpočet ekvivalentní dávky HT"],"activity":"Oznaczanie indywidualnego równoważnika dawki Hp(0,07)\nMetoda TLD","reference":"PP VF 1INT-2328-T03 (metodika VF1INT-2328-M01, kap. 2.2; ISO 12794)","norm_bases":["PP VF 1INT-2328-T03","VF1INT-2328-M01","ISO 12794"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoluminescencyjny dawkomierz indywidualny na kończyny Oznaczanie indywidualnego równoważnika dawki Hp(0,07) Metoda TLD Obliczenie dawki równoważnej HT Termoluminiscenční osobní dozimetr pro končetiny Stanovení osobního dávkového ekvivalentu Hp(0,07) metodou TLD výpočet ekvivalentní dávky HT PP VF 1INT-2328-T03 (metodika VF1INT-2328-M01, kap. 2.2; ISO 12794) Termoluminescencyjny dawkomierz indywidualny na konczyny Oznaczanie indywidualnego rownowaznika dawki Hp(0,07) Metoda TLD Obliczenie dawki rownowaznej HT Termoluminiscencni osobni dozimetr pro koncetiny Stanoveni osobniho davkoveho ekvivalentu Hp(0,07) metodou TLD vypocet ekvivalentni davky HT PP VF 1INT-2328-T03 (metodika VF1INT-2328-M01, kap. 2.2; ISO 12794)","search_en":"Thermoluminescent personal extremity dosimeter Determination of personal dose equivalent Hp(0,07) TLD method Calculation of equivalent dose HT PP VF 1INT-2328-T03 (metodika VF1INT-2328-M01, kap. 2.2; ISO 12794)","search_zh":"四肢用热释光个人剂量计 个人剂量当量Hp(0,07)的测定 TLD法 当量剂量HT的计算 PP VF 1INT-2328-T03 (metodika VF1INT-2328-M01, kap. 2.2; ISO 12794)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}