{"lab":{"_id":"69ad52a4de79e566650fd528","accr_number":"1679","country":"CZ","accr_body":"ČIA","address":"Západní 93, 251 01 Čestlice","categories":["pharma"],"city":"Čestlice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":3,"name":"TRIGON PLUS s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1679_62_2023_CS.pdf","1679_62_2023_EN.pdf"],"scope_summary":"Pomiary czystości powietrza, liczby cząstek i prędkości przepływu w urządzeniach i pomieszczeniach o kontrolowanej czystości powietrza, w tym w komorach z przepływem laminarnym, kontrola defektoskopowa urządzeń filtracji powietrza.","search_text":"trigon plus s.r.o. západní 93, 251 01 čestlice 1679","status":"active","updated_at":"2026-03-08T14:52:14.563Z","valid_from":"","valid_until":"09-02-2028","website":"www.trigonplus.cz","email_confidence":"low","email_mx":false,"email_source":"https://www.trigonplus.cz","needs_review":true,"review_reason":"domena bez MX — zweryfikuj","map_coord":[50.007289,14.582985],"map_geo":"nominatim-street","certificate_date":"09.02.2023","certificate_no":"62/2023","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Pomiary czystości powietrza, liczby cząstek i prędkości przepływu w urządzeniach i pomieszczeniach o kontrolowanej czystości powietrza, w tym w komorach z przepływem laminarnym, kontrola defektoskopowa urządzeń filtracji powietrza.","en":"Measurement of air cleanliness, particle count, flow velocity in equipment and spaces with air cleanliness control including laminar flow hoods, defectoscopy of air filtering equipment.","zh":"空气洁净度受控的设备和场所（包括层流罩）的空气洁净度、粒子数量和气流速度测量，空气过滤设备的探伤检查。","cs":"Měření čistoty vzduchu, množství částic, rychlosti proudění v zařízeních a prostorách s řízenou čistotou vzduchu včetně laminárních boxů, defektoskopie vzduchových filtračních zařízení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"TRIGON PLUS, laboratorium badawcze","lab_division_cs":"TRIGON PLUS, zkušební laboratoř","lab_division_en":"TRIGON PLUS, Testing Laboratory","lab_division_zh":"TRIGON PLUS 检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"ZL-PP","pl":"procedura badawcza TRIGON PLUS, laboratorium badawcze","en":"Test Procedure TRIGON PLUS, Testing Laboratory","zh":"TRIGON PLUS 检测实验室试验程序","cs":"zkušební postup TRIGON PLUS, zkušební laboratoř"},{"abbr":"GMP","pl":"przepisy Komisji Europejskiej dotyczące dobrej praktyki wytwarzania produktów leczniczych stosowanych u ludzi i zwierząt","en":"European Commission regulations for good manufacturing practice for medicinal products for human and veterinary use","zh":"欧盟委员会关于人用和兽用药品生产质量管理规范的法规","cs":"předpisy Evropské komise pro správnou výrobní praxi v oblasti léčivých přípravků pro humánní a veterinární použití"},{"abbr":"VYR","pl":"przepisy Państwowego Instytutu Kontroli Leków (Czechy) dotyczące dobrej praktyki wytwarzania produktów leczniczych stosowanych u ludzi i zwierząt","en":"regulations of the State Institute for Drug Control for good manufacturing practice for medicinal products for human and veterinary use","zh":"捷克国家药品管理局关于人用和兽用药品生产质量管理规范的法规","cs":"předpisy Státního ústavu pro kontrolu léčiv pro správnou výrobní praxi v oblasti léčivých přípravků pro humánní a veterinární použití"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interprets test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"9ba12f83d45c0eccdefcc445e104ad2416fc8fb476db0dc9b7922f6081b07acb","source_pdf_url":"https://www.cai.cz/OA/pdf/P62_2023_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P62_2023_EN.pdf"},"methods":[{"_id":"4878aed377ad1f592afd130d","lab_id":"69ad52a4de79e566650fd528","country":"CZ","accr_number":"1679","accr_body":"ČIA","row_label":"1","test_object":"Urządzenia i pomieszczenia o kontrolowanej czystości powietrza i gazów","test_object_en":"Clean rooms and equipment with air and gas cleanliness control","test_object_zh":"空气和气体洁净度受控的设备和场所","test_object_cs":"Zařízení a prostory s řízenou čistotou vzduchu a plynů.","methodology":"Oznaczanie średniej prędkości i równomierności przepływu","methodology_en":"Determination of mean flow velocity and flow uniformity","methodology_zh":"平均气流速度和气流均匀性测定","methodology_cs":"Stanovení střední rychlosti a rovnoměrnosti proudění","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie średniej prędkości i równomierności przepływu","reference":"ZL-PP-01 (ČSN EN 12469; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1)","norm_bases":["ZL-PP-01","ČSN EN 12469","ČSN EN ISO 14644-3","EU GMP Annex 1","VYR-32 Doplněk 1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia i pomieszczenia o kontrolowanej czystości powietrza i gazów Oznaczanie średniej prędkości i równomierności przepływu Zařízení a prostory s řízenou čistotou vzduchu a plynů. Stanovení střední rychlosti a rovnoměrnosti proudění ZL-PP-01 (ČSN EN 12469; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1) Urzadzenia i pomieszczenia o kontrolowanej czystosci powietrza i gazow Oznaczanie sredniej predkosci i rownomiernosci przeplywu Zarizeni a prostory s rizenou cistotou vzduchu a plynu. Stanoveni stredni rychlosti a rovnomernosti proudeni ZL-PP-01 (CSN EN 12469; CSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplnek 1)","search_en":"Clean rooms and equipment with air and gas cleanliness control Determination of mean flow velocity and flow uniformity ZL-PP-01 (ČSN EN 12469; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1)","search_zh":"空气和气体洁净度受控的设备和场所 平均气流速度和气流均匀性测定 ZL-PP-01 (ČSN EN 12469; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1)","categories":["pharma"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f996824092536399a419cec","lab_id":"69ad52a4de79e566650fd528","country":"CZ","accr_number":"1679","accr_body":"ČIA","row_label":"2","test_object":"Urządzenia i pomieszczenia o kontrolowanej czystości powietrza i gazów","test_object_en":"Clean rooms and equipment with air and gas cleanliness control","test_object_zh":"空气和气体洁净度受控的设备和场所","test_object_cs":"Zařízení a prostory s řízenou čistotou vzduchu a plynů.","methodology":"Pomiar liczby cząstek aerozolu w powietrzu i gazach","methodology_en":"Enumeration of aerosol particles in air and gas","methodology_zh":"空气和气体中气溶胶粒子计数","methodology_cs":"Měření počtu částic aerosolů ve vzduchu a plynech","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Licznik cząstek laserowy","technique_en":"with a laser particle counter","technique_zh":"激光粒子计数器法","technique_cs":"laserovým měřičem částic","techniques":["Licznik cząstek laserowy"],"techniques_en":["with a laser particle counter"],"techniques_zh":["激光粒子计数器法"],"techniques_cs":["laserovým měřičem částic"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar liczby cząstek aerozolu w powietrzu i gazach\nLicznik cząstek laserowy","reference":"ZL-PP-02 (ČSN EN ISO 14644-1; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1)","norm_bases":["ZL-PP-02","ČSN EN ISO 14644-1","ČSN EN ISO 14644-3","EU GMP Annex 1","VYR-32 Doplněk 1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia i pomieszczenia o kontrolowanej czystości powietrza i gazów Pomiar liczby cząstek aerozolu w powietrzu i gazach Licznik cząstek laserowy Zařízení a prostory s řízenou čistotou vzduchu a plynů. Měření počtu částic aerosolů ve vzduchu a plynech laserovým měřičem částic ZL-PP-02 (ČSN EN ISO 14644-1; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1) Urzadzenia i pomieszczenia o kontrolowanej czystosci powietrza i gazow Pomiar liczby czastek aerozolu w powietrzu i gazach Licznik czastek laserowy Zarizeni a prostory s rizenou cistotou vzduchu a plynu. Mereni poctu castic aerosolu ve vzduchu a plynech laserovym mericem castic ZL-PP-02 (CSN EN ISO 14644-1; CSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplnek 1)","search_en":"Clean rooms and equipment with air and gas cleanliness control Enumeration of aerosol particles in air and gas with a laser particle counter ZL-PP-02 (ČSN EN ISO 14644-1; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1)","search_zh":"空气和气体洁净度受控的设备和场所 空气和气体中气溶胶粒子计数 激光粒子计数器法 ZL-PP-02 (ČSN EN ISO 14644-1; ČSN EN ISO 14644-3; EU GMP Annex 1; VYR-32 Doplněk 1)","categories":["pharma"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d747c98ad33ca6449e6f02be","lab_id":"69ad52a4de79e566650fd528","country":"CZ","accr_number":"1679","accr_body":"ČIA","row_label":"3","test_object":"Wysokoskuteczne wkłady filtracyjne aerozoli","test_object_en":"High performance aerosol filter cartridges","test_object_zh":"高效气溶胶过滤滤芯","test_object_cs":"Vysokoúčinné filtrační aerosolové vložky","methodology":"Kontrola defektoskopowa filtrów","methodology_en":"Non destructive inspection of filters","methodology_zh":"过滤器无损探伤检查","methodology_cs":"Defektoskopická kontrola filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Licznik cząstek laserowy","technique_en":"by a laser particle counter","technique_zh":"激光粒子计数器法","technique_cs":"laserovým měřičem částic","techniques":["Licznik cząstek laserowy"],"techniques_en":["by a laser particle counter"],"techniques_zh":["激光粒子计数器法"],"techniques_cs":["laserovým měřičem částic"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Kontrola defektoskopowa filtrów\nLicznik cząstek laserowy","reference":"ZL-PP-03 (ČSN EN 12469; ČSN EN ISO 14644-3)","norm_bases":["ZL-PP-03","ČSN EN 12469","ČSN EN ISO 14644-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wysokoskuteczne wkłady filtracyjne aerozoli Kontrola defektoskopowa filtrów Licznik cząstek laserowy Vysokoúčinné filtrační aerosolové vložky Defektoskopická kontrola filtrů laserovým měřičem částic ZL-PP-03 (ČSN EN 12469; ČSN EN ISO 14644-3) Wysokoskuteczne wklady filtracyjne aerozoli Kontrola defektoskopowa filtrow Licznik czastek laserowy Vysokoucinne filtracni aerosolove vlozky Defektoskopicka kontrola filtru laserovym mericem castic ZL-PP-03 (CSN EN 12469; CSN EN ISO 14644-3)","search_en":"High performance aerosol filter cartridges Non destructive inspection of filters by a laser particle counter ZL-PP-03 (ČSN EN 12469; ČSN EN ISO 14644-3)","search_zh":"高效气溶胶过滤滤芯 过滤器无损探伤检查 激光粒子计数器法 ZL-PP-03 (ČSN EN 12469; ČSN EN ISO 14644-3)","categories":["pharma"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}