{"lab":{"_id":"69ad52a4de79e566650fd50c","country":"CZ","accr_number":"1661","accr_body":"ČIA","address":"Lidické náměstí 9, 401 79 Ústí nad Labem","categories":["other"],"city":"Ústí nad Labem","imported_at":"2026-03-08T10:42:44.590Z","methods_count":5,"name":"Policie ČR, Krajské ředitelství policie Ústeckého kraje se sídlem v Ústí nad Labem","parse_status":"parsed","parse_version":5,"pdf_files":["1661_613_2024_CS.pdf","1661_613_2024_EN.pdf"],"scope_summary":"Badania kryminalistyczne.","search_text":"policie čr, krajské ředitelství policie ústeckého kraje se sídlem v ústí nad labem lidické náměstí 9, 401 79 ústí nad labem 1661","status":"active","updated_at":"2026-03-08T14:52:14.449Z","valid_from":"","valid_until":"10-02-2027","website":"www.policie.cz","location":{"type":"Point","coordinates":[14.0323,50.6607]},"email_confidence":"low","email_mx":true,"email_source":"https://www.policie.cz/kontakty","needs_review":true,"review_reason":"e-mail ze strony (domena inna niż WWW) — zweryfikuj","map_coord":[50.659879,14.036037],"map_geo":"nominatim-street","certificate_date":"19.11.2024","certificate_no":"613/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania kryminalistyczne.","en":"Forensic testing.","zh":"法证检验。","cs":"Forenzní zkoušení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Wydział Techniki Kryminalistycznej i Ekspertyz","lab_division_cs":"Odbor kriminalistické techniky a expertiz","lab_division_en":"Department of Forensic Technology and Expertise","lab_division_zh":"刑事技术与鉴定处","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"XXX - Y","pl":"wewnętrzna procedura laboratorium","en":"internal laboratory procedure","zh":"实验室内部程序","cs":"interní postup laboratoře"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie fachowe i interpretacje wyników badań.","en":"The laboratory provides expert opinions and interpretations of test results.","zh":"实验室提供检测结果的专业意见和解释。","cs":"Laboratoř poskytuje odborná stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"6623199ef8a7c06ae1a096a83b53bfb4732a243a4936f5ab553d6c5b23fcce77","source_pdf_url":"https://www.cai.cz/OA/pdf/P613_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"f4e4fe52c3ce14fbcaf05087","lab_id":"69ad52a4de79e566650fd50c","country":"CZ","accr_number":"1661","accr_body":"ČIA","row_label":"1","test_object":"Materiał kryminalistyczny","test_object_en":"Forensic material","test_object_zh":"法证材料","test_object_cs":"Forenzní materiál","methodology":"Identyfikacja daktyloskopijna na podstawie cech charakterystycznych linii papilarnych","methodology_en":"Fingerprint identification based on characteristic features of papillary ridges","methodology_zh":"依据乳突纹特征点的指纹鉴定","methodology_cs":"Daktyloskopická identifikace podle charakteristických znaků papilárních linií","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Identyfikacja daktyloskopijna na podstawie cech charakterystycznych linii papilarnych","reference":"DKT-1","norm_bases":["DKT-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał kryminalistyczny Identyfikacja daktyloskopijna na podstawie cech charakterystycznych linii papilarnych Forenzní materiál Daktyloskopická identifikace podle charakteristických znaků papilárních linií DKT-1 Material kryminalistyczny Identyfikacja daktyloskopijna na podstawie cech charakterystycznych linii papilarnych Forenzni material Daktyloskopicka identifikace podle charakteristickych znaku papilarnich linii DKT-1","search_en":"Forensic material Fingerprint identification based on characteristic features of papillary ridges DKT-1","search_zh":"法证材料 依据乳突纹特征点的指纹鉴定 DKT-1","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1cd317fee267badd348743cf","lab_id":"69ad52a4de79e566650fd50c","country":"CZ","accr_number":"1661","accr_body":"ČIA","row_label":"2","test_object":"Materiał kryminalistyczny","test_object_en":"Forensic material","test_object_zh":"法证材料","test_object_cs":"Forenzní materiál","methodology":"Izolacja DNA","methodology_en":"DNA isolation","methodology_zh":"DNA提取","methodology_cs":"Izolace DNA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izolacja DNA","reference":"GEN - 1","norm_bases":["GEN - 1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał kryminalistyczny Izolacja DNA Forenzní materiál Izolace DNA GEN - 1 Material kryminalistyczny Izolacja DNA Forenzni material Izolace DNA GEN - 1","search_en":"Forensic material DNA isolation GEN - 1","search_zh":"法证材料 DNA提取 GEN - 1","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f1d78e9e6344e65bc06bb7f","lab_id":"69ad52a4de79e566650fd50c","country":"CZ","accr_number":"1661","accr_body":"ČIA","row_label":"3","test_object":"Materiał kryminalistyczny","test_object_en":"Forensic material","test_object_zh":"法证材料","test_object_cs":"Forenzní materiál","methodology":"Oznaczanie stężenia DNA","methodology_en":"Determination of DNA concentration","methodology_zh":"DNA浓度测定","methodology_cs":"Stanovení koncentrace DNA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Ilościowa reakcja PCR w czasie rzeczywistym (Real-Time PCR)","technique_en":"Quantitative real-time PCR","technique_zh":"实时荧光定量PCR","technique_cs":"pomocí kvantitativní Real-Time PCR","techniques":["Ilościowa reakcja PCR w czasie rzeczywistym (Real-Time PCR)"],"techniques_en":["Quantitative real-time PCR"],"techniques_zh":["实时荧光定量PCR"],"techniques_cs":["pomocí kvantitativní Real-Time PCR"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia DNA\nIlościowa reakcja PCR w czasie rzeczywistym (Real-Time PCR)","reference":"GEN - 2","norm_bases":["GEN - 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał kryminalistyczny Oznaczanie stężenia DNA Ilościowa reakcja PCR w czasie rzeczywistym (Real-Time PCR) Forenzní materiál Stanovení koncentrace DNA pomocí kvantitativní Real-Time PCR GEN - 2 Material kryminalistyczny Oznaczanie stezenia DNA Ilosciowa reakcja PCR w czasie rzeczywistym (Real-Time PCR) Forenzni material Stanoveni koncentrace DNA pomoci kvantitativni Real-Time PCR GEN - 2","search_en":"Forensic material Determination of DNA concentration Quantitative real-time PCR GEN - 2","search_zh":"法证材料 DNA浓度测定 实时荧光定量PCR GEN - 2","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"df2c62932b3b92334d7505bc","lab_id":"69ad52a4de79e566650fd50c","country":"CZ","accr_number":"1661","accr_body":"ČIA","row_label":"4","test_object":"Materiał kryminalistyczny","test_object_en":"Forensic material","test_object_zh":"法证材料","test_object_cs":"Forenzní materiál","methodology":"Amplifikacja polimorficznych regionów DNA","methodology_en":"Amplification of polymorphic DNA regions","methodology_zh":"DNA多态性区域扩增","methodology_cs":"Amplifikace polymorfních oblastí DNA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Amplifikacja polimorficznych regionów DNA","reference":"GEN - 3","norm_bases":["GEN - 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał kryminalistyczny Amplifikacja polimorficznych regionów DNA Forenzní materiál Amplifikace polymorfních oblastí DNA GEN - 3 Material kryminalistyczny Amplifikacja polimorficznych regionow DNA Forenzni material Amplifikace polymorfnich oblasti DNA GEN - 3","search_en":"Forensic material Amplification of polymorphic DNA regions GEN - 3","search_zh":"法证材料 DNA多态性区域扩增 GEN - 3","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"755ceefb46e1d3264c2667bf","lab_id":"69ad52a4de79e566650fd50c","country":"CZ","accr_number":"1661","accr_body":"ČIA","row_label":"5","test_object":"Materiał kryminalistyczny","test_object_en":"Forensic material","test_object_zh":"法证材料","test_object_cs":"Forenzní materiál","methodology":"Identyfikacja ludzkiego materiału biologicznego","methodology_en":"Identification of human biological material","methodology_zh":"人类生物材料鉴定","methodology_cs":"Identifikace lidského biologického materiálu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda analizy fragmentów","technique_en":"Fragment analysis","technique_zh":"片段分析法","technique_cs":"metodou fragmentační analýzy","techniques":["Metoda analizy fragmentów"],"techniques_en":["Fragment analysis"],"techniques_zh":["片段分析法"],"techniques_cs":["metodou fragmentační analýzy"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Identyfikacja ludzkiego materiału biologicznego\nMetoda analizy fragmentów","reference":"GEN - 4","norm_bases":["GEN - 4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał kryminalistyczny Identyfikacja ludzkiego materiału biologicznego Metoda analizy fragmentów Forenzní materiál Identifikace lidského biologického materiálu metodou fragmentační analýzy GEN - 4 Material kryminalistyczny Identyfikacja ludzkiego materialu biologicznego Metoda analizy fragmentow Forenzni material Identifikace lidskeho biologickeho materialu metodou fragmentacni analyzy GEN - 4","search_en":"Forensic material Identification of human biological material Fragment analysis GEN - 4","search_zh":"法证材料 人类生物材料鉴定 片段分析法 GEN - 4","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}