{"lab":{"_id":"69ad52a4de79e566650fd50a","accr_number":"1659","country":"CZ","accr_body":"ČIA","address":"Technická 2, 166 27 Praha 6 - Dejvice","categories":["electronics"],"city":"Praha 6 - Dejvice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":5,"name":"České vysoké učení technické v Praze","parse_status":"parsed","parse_version":5,"pdf_files":["1659_26_2026_CS.pdf","1659_26_2026_EN.pdf"],"scope_summary":"Pomiary parametrów modułów fotowoltaicznych wykonanych w różnych technologiach","search_text":"české vysoké učení technické v praze technická 2, 166 27 praha 6 - dejvice 1659","status":"active","updated_at":"2026-03-08T14:52:14.448Z","valid_from":"","valid_until":"13-01-2027","website":"","location":{"type":"Point","coordinates":[14.4378,50.0755]},"map_coord":[50.102536,14.392827],"map_geo":"nominatim-street","certificate_date":"13.01.2026","certificate_no":"26/2026","certificate_replaces":"409/2024 z 20.08.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Pomiary parametrów modułów fotowoltaicznych wykonanych w różnych technologiach","en":"Measurement of the parameters of photovoltaic modules manufactured by various technologies","zh":"不同工艺制造的光伏组件参数测量","cs":"Měření parametrů fotovoltaických modulů vyrobených různou technologií"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Diagnostyki Systemów Fotowoltaicznych (LDFS)","lab_division_cs":"Laboratoř diagnostiky fotovoltaických systémů (LDFS)","lab_division_en":"Laboratory for the Photovoltaic Systems Diagnostics (LPVSD)","lab_division_zh":"光伏系统诊断实验室（LDFS）","lab_locations":[{"code":null,"name":"České vysoké učení technické v Praze","street":"Technická 2","postal_code":"166 27","city":"Praha 6 - Dejvice","is_hq":true,"address":"Technická 2, 166 27 Praha 6 - Dejvice","site":"16627|technická2"},{"code":null,"name":"Laboratorium modułów PV (LPVM)","street":"Technická 2","postal_code":"166 27","city":"Praha 6","is_hq":false,"address":"Technická 2, 166 27 Praha 6","site":"16627|technická2"},{"code":null,"name":"Laboratorium przekształtników","street":"Třinecká 1024","postal_code":"273 43","city":"Buštěhrad","is_hq":false,"address":"Třinecká 1024, 273 43 Buštěhrad","site":"27343|třinecká1024"}],"lab_locations_en":[{"code":null,"name":"České vysoké učení technické v Praze","street":"Technická 2","postal_code":"166 27","city":"Praha 6 - Dejvice","is_hq":true,"address":"Technická 2, 166 27 Praha 6 - Dejvice","site":"16627|technická2"},{"code":null,"name":"Laboratory of PV Modules LPVM","street":"Technická 2","postal_code":"166 27","city":"Praha 6","is_hq":false,"address":"Technická 2, 166 27 Praha 6","site":"16627|technická2"},{"code":null,"name":"Power Converters Laboratory","street":"Třinecká 1024","postal_code":"273 43","city":"Buštěhrad","is_hq":false,"address":"Třinecká 1024, 273 43 Buštěhrad","site":"27343|třinecká1024"}],"lab_locations_zh":[{"code":null,"name":"České vysoké učení technické v Praze","street":"Technická 2","postal_code":"166 27","city":"Praha 6 - Dejvice","is_hq":true,"address":"Technická 2, 166 27 Praha 6 - Dejvice","site":"16627|technická2"},{"code":null,"name":"光伏组件实验室（LPVM）","street":"Technická 2","postal_code":"166 27","city":"Praha 6","is_hq":false,"address":"Technická 2, 166 27 Praha 6","site":"16627|technická2"},{"code":null,"name":"变流器实验室","street":"Třinecká 1024","postal_code":"273 43","city":"Buštěhrad","is_hq":false,"address":"Třinecká 1024, 273 43 Buštěhrad","site":"27343|třinecká1024"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"BZP_XX_A","pl":"Procedura badawcza LDFS","en":"LDFS test procedure","zh":"LDFS检测程序","cs":"Zkušební postup LDFS"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"27033e7786a9f86d784dd777e1a0ca9c3843e5ce2dfcf688794dae4be6a87d5a","source_pdf_url":"https://www.cai.cz/OA/pdf/26_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/26_2026_EN.pdf"},"methods":[{"_id":"8827c673276d44af11d1a1ef","lab_id":"69ad52a4de79e566650fd50a","country":"CZ","accr_number":"1659","accr_body":"ČIA","row_label":"1","test_object":"Moduły fotowoltaiczne","test_object_en":"Photovoltaic Modules","test_object_zh":"光伏组件","test_object_cs":"Fotovoltaické moduly","methodology":"Pomiar charakterystyki prądowo-napięciowej","methodology_en":"Measurement of Volt-Ampere Characteristic","methodology_zh":"伏安特性测量","methodology_cs":"Měření Volt-Ampérové charakteristiky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar charakterystyki prądowo-napięciowej","reference":"BZP_01_A (ČSN EN IEC 60904-1 ed. 3, čl. 7; ČSN EN 60904-1 ed. 2:2007, čl. 7; ČSN EN IEC 61215-2 ed. 2, čl. 4.2, 4.6, 4.7; ČSN EN 61215-2:2017, čl. 4.2, 4.6, 4.7; ČSN EN 61215:1997, čl. 10.2, 10.6, 10.7; ČSN EN 61215 ed. 2:2006, čl. 10.2, 10.6, 10.7; ČSN EN 61646:1999, čl. 10.2, 10.6, 10.7; ČSN EN 61646 ed. 2:2009, čl. 10.2, 10.6, 10.7)","norm_bases":["BZP_01_A","ČSN EN IEC 60904-1 ed. 3, čl. 7","ČSN EN 60904-1 ed. 2:2007, čl. 7","ČSN EN IEC 61215-2 ed. 2, čl. 4.2, 4.6, 4.7","ČSN EN 61215-2:2017, čl. 4.2, 4.6, 4.7","ČSN EN 61215:1997, čl. 10.2, 10.6, 10.7","ČSN EN 61215 ed. 2:2006, čl. 10.2, 10.6, 10.7","ČSN EN 61646:1999, čl. 10.2, 10.6, 10.7","ČSN EN 61646 ed. 2:2009, čl. 10.2, 10.6, 10.7"],"lab_section":"Laboratorium modułów PV (LPVM)","lab_section_en":"Laboratory of PV Modules LPVM","lab_section_zh":"光伏组件实验室（LPVM）","lab_section_cs":"Laboratoř PV modulů LPVM","lab_address":"Technická 2, 166 27 Praha 6","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduły fotowoltaiczne Pomiar charakterystyki prądowo-napięciowej Fotovoltaické moduly Měření Volt-Ampérové charakteristiky BZP_01_A (ČSN EN IEC 60904-1 ed. 3, čl. 7; ČSN EN 60904-1 ed. 2:2007, čl. 7; ČSN EN IEC 61215-2 ed. 2, čl. 4.2, 4.6, 4.7; ČSN EN 61215-2:2017, čl. 4.2, 4.6, 4.7; ČSN EN 61215:1997, čl. 10.2, 10.6, 10.7; ČSN EN 61215 ed. 2:2006, čl. 10.2, 10.6, 10.7; ČSN EN 61646:1999, čl. 10.2, 10.6, 10.7; ČSN EN 61646 ed. 2:2009, čl. 10.2, 10.6, 10.7) Moduly fotowoltaiczne Pomiar charakterystyki pradowo-napieciowej Fotovoltaicke moduly Mereni Volt-Amperove charakteristiky BZP_01_A (CSN EN IEC 60904-1 ed. 3, cl. 7; CSN EN 60904-1 ed. 2:2007, cl. 7; CSN EN IEC 61215-2 ed. 2, cl. 4.2, 4.6, 4.7; CSN EN 61215-2:2017, cl. 4.2, 4.6, 4.7; CSN EN 61215:1997, cl. 10.2, 10.6, 10.7; CSN EN 61215 ed. 2:2006, cl. 10.2, 10.6, 10.7; CSN EN 61646:1999, cl. 10.2, 10.6, 10.7; CSN EN 61646 ed. 2:2009, cl. 10.2, 10.6, 10.7)","search_en":"Photovoltaic Modules Measurement of Volt-Ampere Characteristic BZP_01_A (ČSN EN IEC 60904-1 ed. 3, čl. 7; ČSN EN 60904-1 ed. 2:2007, čl. 7; ČSN EN IEC 61215-2 ed. 2, čl. 4.2, 4.6, 4.7; ČSN EN 61215-2:2017, čl. 4.2, 4.6, 4.7; ČSN EN 61215:1997, čl. 10.2, 10.6, 10.7; ČSN EN 61215 ed. 2:2006, čl. 10.2, 10.6, 10.7; ČSN EN 61646:1999, čl. 10.2, 10.6, 10.7; ČSN EN 61646 ed. 2:2009, čl. 10.2, 10.6, 10.7)","search_zh":"光伏组件 伏安特性测量 BZP_01_A (ČSN EN IEC 60904-1 ed. 3, čl. 7; ČSN EN 60904-1 ed. 2:2007, čl. 7; ČSN EN IEC 61215-2 ed. 2, čl. 4.2, 4.6, 4.7; ČSN EN 61215-2:2017, čl. 4.2, 4.6, 4.7; ČSN EN 61215:1997, čl. 10.2, 10.6, 10.7; ČSN EN 61215 ed. 2:2006, čl. 10.2, 10.6, 10.7; ČSN EN 61646:1999, čl. 10.2, 10.6, 10.7; ČSN EN 61646 ed. 2:2009, čl. 10.2, 10.6, 10.7)","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2287d5fd16a8efedf129992a","lab_id":"69ad52a4de79e566650fd50a","country":"CZ","accr_number":"1659","accr_body":"ČIA","row_label":"2","test_object":"Moduły fotowoltaiczne","test_object_en":"Photovoltaic Modules","test_object_zh":"光伏组件","test_object_cs":"Fotovoltaické moduly","methodology":"Pomiar wytrzymałości elektrycznej","methodology_en":"Dielectric withstand test","methodology_zh":"介电强度测量","methodology_cs":"Měření elektrické pevnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar wytrzymałości elektrycznej","reference":"BZP_03_A (ČSN EN IEC 61730-2 ed. 2, čl. 10.13; ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3)","norm_bases":["BZP_03_A","ČSN EN IEC 61730-2 ed. 2, čl. 10.13","ČSN EN IEC 61215-2 ed. 2, čl. 4.3","ČSN EN 61215-2:2017, čl. 4.3","ČSN EN 61215:1997, čl. 10.3","ČSN EN 61215 ed. 2:2006, čl. 10.3","ČSN EN 61646:1999, čl. 10.3","ČSN EN 61646 ed. 2:2009, čl. 10.3"],"lab_section":"Laboratorium modułów PV (LPVM)","lab_section_en":"Laboratory of PV Modules LPVM","lab_section_zh":"光伏组件实验室（LPVM）","lab_section_cs":"Laboratoř PV modulů LPVM","lab_address":"Technická 2, 166 27 Praha 6","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduły fotowoltaiczne Pomiar wytrzymałości elektrycznej Fotovoltaické moduly Měření elektrické pevnosti BZP_03_A (ČSN EN IEC 61730-2 ed. 2, čl. 10.13; ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3) Moduly fotowoltaiczne Pomiar wytrzymalosci elektrycznej Fotovoltaicke moduly Mereni elektricke pevnosti BZP_03_A (CSN EN IEC 61730-2 ed. 2, cl. 10.13; CSN EN IEC 61215-2 ed. 2, cl. 4.3; CSN EN 61215-2:2017, cl. 4.3; CSN EN 61215:1997, cl. 10.3; CSN EN 61215 ed. 2:2006, cl. 10.3; CSN EN 61646:1999, cl. 10.3; CSN EN 61646 ed. 2:2009, cl. 10.3)","search_en":"Photovoltaic Modules Dielectric withstand test BZP_03_A (ČSN EN IEC 61730-2 ed. 2, čl. 10.13; ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3)","search_zh":"光伏组件 介电强度测量 BZP_03_A (ČSN EN IEC 61730-2 ed. 2, čl. 10.13; ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3)","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2ffa8962e3daaf4cc85d2b00","lab_id":"69ad52a4de79e566650fd50a","country":"CZ","accr_number":"1659","accr_body":"ČIA","row_label":"3","test_object":"Moduły fotowoltaiczne","test_object_en":"Photovoltaic Modules","test_object_zh":"光伏组件","test_object_cs":"Fotovoltaické moduly","methodology":"Pomiar rezystancji izolacji","methodology_en":"Insulation resistance test","methodology_zh":"绝缘电阻测量","methodology_cs":"Měření izolačního odporu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar rezystancji izolacji","reference":"BZP_04_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3; ČSN EN 62446-1+A1, čl. 6.7)","norm_bases":["BZP_04_A","ČSN EN IEC 61215-2 ed. 2, čl. 4.3","ČSN EN 61215-2:2017, čl. 4.3","ČSN EN 61215:1997, čl. 10.3","ČSN EN 61215 ed. 2:2006, čl. 10.3","ČSN EN 61646:1999, čl. 10.3","ČSN EN 61646 ed. 2:2009, čl. 10.3","ČSN EN 62446-1+A1, čl. 6.7"],"lab_section":"Laboratorium modułów PV (LPVM)","lab_section_en":"Laboratory of PV Modules LPVM","lab_section_zh":"光伏组件实验室（LPVM）","lab_section_cs":"Laboratoř PV modulů LPVM","lab_address":"Technická 2, 166 27 Praha 6","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduły fotowoltaiczne Pomiar rezystancji izolacji Fotovoltaické moduly Měření izolačního odporu BZP_04_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3; ČSN EN 62446-1+A1, čl. 6.7) Moduly fotowoltaiczne Pomiar rezystancji izolacji Fotovoltaicke moduly Mereni izolacniho odporu BZP_04_A (CSN EN IEC 61215-2 ed. 2, cl. 4.3; CSN EN 61215-2:2017, cl. 4.3; CSN EN 61215:1997, cl. 10.3; CSN EN 61215 ed. 2:2006, cl. 10.3; CSN EN 61646:1999, cl. 10.3; CSN EN 61646 ed. 2:2009, cl. 10.3; CSN EN 62446-1+A1, cl. 6.7)","search_en":"Photovoltaic Modules Insulation resistance test BZP_04_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3; ČSN EN 62446-1+A1, čl. 6.7)","search_zh":"光伏组件 绝缘电阻测量 BZP_04_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.3; ČSN EN 61215-2:2017, čl. 4.3; ČSN EN 61215:1997, čl. 10.3; ČSN EN 61215 ed. 2:2006, čl. 10.3; ČSN EN 61646:1999, čl. 10.3; ČSN EN 61646 ed. 2:2009, čl. 10.3; ČSN EN 62446-1+A1, čl. 6.7)","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a5b58d3a8f2d512d06661b40","lab_id":"69ad52a4de79e566650fd50a","country":"CZ","accr_number":"1659","accr_body":"ČIA","row_label":"4","test_object":"Moduły fotowoltaiczne","test_object_en":"Photovoltaic Modules","test_object_zh":"光伏组件","test_object_cs":"Fotovoltaické moduly","methodology":"Oględziny","methodology_en":"Visual Inspection","methodology_zh":"外观检查","methodology_cs":"Vizuální kontrola","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oględziny","reference":"BZP_06_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.1; ČSN EN 61215-2:2017, čl. 4.1; ČSN EN 61215:1997, čl. 10.1; ČSN EN 61215 ed. 2:2006, čl. 10.1; ČSN EN 61646:1999, čl. 10.1; ČSN EN 61646 ed. 2:2009, čl. 10.1)","norm_bases":["BZP_06_A","ČSN EN IEC 61215-2 ed. 2, čl. 4.1","ČSN EN 61215-2:2017, čl. 4.1","ČSN EN 61215:1997, čl. 10.1","ČSN EN 61215 ed. 2:2006, čl. 10.1","ČSN EN 61646:1999, čl. 10.1","ČSN EN 61646 ed. 2:2009, čl. 10.1"],"lab_section":"Laboratorium modułów PV (LPVM)","lab_section_en":"Laboratory of PV Modules LPVM","lab_section_zh":"光伏组件实验室（LPVM）","lab_section_cs":"Laboratoř PV modulů LPVM","lab_address":"Technická 2, 166 27 Praha 6","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moduły fotowoltaiczne Oględziny Fotovoltaické moduly Vizuální kontrola BZP_06_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.1; ČSN EN 61215-2:2017, čl. 4.1; ČSN EN 61215:1997, čl. 10.1; ČSN EN 61215 ed. 2:2006, čl. 10.1; ČSN EN 61646:1999, čl. 10.1; ČSN EN 61646 ed. 2:2009, čl. 10.1) Moduly fotowoltaiczne Ogledziny Fotovoltaicke moduly Vizualni kontrola BZP_06_A (CSN EN IEC 61215-2 ed. 2, cl. 4.1; CSN EN 61215-2:2017, cl. 4.1; CSN EN 61215:1997, cl. 10.1; CSN EN 61215 ed. 2:2006, cl. 10.1; CSN EN 61646:1999, cl. 10.1; CSN EN 61646 ed. 2:2009, cl. 10.1)","search_en":"Photovoltaic Modules Visual Inspection BZP_06_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.1; ČSN EN 61215-2:2017, čl. 4.1; ČSN EN 61215:1997, čl. 10.1; ČSN EN 61215 ed. 2:2006, čl. 10.1; ČSN EN 61646:1999, čl. 10.1; ČSN EN 61646 ed. 2:2009, čl. 10.1)","search_zh":"光伏组件 外观检查 BZP_06_A (ČSN EN IEC 61215-2 ed. 2, čl. 4.1; ČSN EN 61215-2:2017, čl. 4.1; ČSN EN 61215:1997, čl. 10.1; ČSN EN 61215 ed. 2:2006, čl. 10.1; ČSN EN 61646:1999, čl. 10.1; ČSN EN 61646 ed. 2:2009, čl. 10.1)","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9e7fb2574c13d531dcd3638c","lab_id":"69ad52a4de79e566650fd50a","country":"CZ","accr_number":"1659","accr_body":"ČIA","row_label":"5","test_object":"Niesynchroniczne moduły wytwórcze kategorii A1 i A2","test_object_en":"Power Park Modules type A1 and A2","test_object_zh":"A1和A2类非同步发电模块","test_object_cs":"Nesynchronní výrobní moduly kategorie A1 a A2","methodology":"Pomiar przebiegów czasowych napięcia, prądu, mocy i częstotliwości","methodology_en":"Measurement of Voltage, Current, Power, and Frequency Time Profiles","methodology_zh":"电压、电流、功率和频率时间曲线测量","methodology_cs":"Měření časových průběhů napětí, proudu, výkonu a frekvence","parameters":[{"name":"Napięcie","range":""},{"name":"Prąd","range":""},{"name":"Moc","range":""},{"name":"Częstotliwość","range":""}],"parameters_en":[{"name":"Voltage","range":""},{"name":"Current","range":""},{"name":"Power","range":""},{"name":"Frequency","range":""}],"parameters_zh":[{"name":"电压","range":""},{"name":"电流","range":""},{"name":"功率","range":""},{"name":"频率","range":""}],"parameters_cs":[{"name":"napětí","range":""},{"name":"proudu","range":""},{"name":"výkonu","range":""},{"name":"frekvence","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar przebiegów czasowych napięcia, prądu, mocy i częstotliwości\nZakres:\nNapięcie\nPrąd\nMoc\nCzęstotliwość","reference":"BZP_07_A (Metodika pro testování nesynchronní komponenty výrobního modulu kategorie A1 a A2)","norm_bases":["BZP_07_A","Metodika pro testování nesynchronní komponenty výrobního modulu kategorie A1 a A2"],"lab_section":"Laboratorium przekształtników","lab_section_en":"Power Converters Laboratory","lab_section_zh":"变流器实验室","lab_section_cs":"Laboratoř měničů","lab_address":"Třinecká 1024, 273 43 Buštěhrad","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Niesynchroniczne moduły wytwórcze kategorii A1 i A2 Pomiar przebiegów czasowych napięcia, prądu, mocy i częstotliwości Napięcie  Prąd  Moc  Częstotliwość  Nesynchronní výrobní moduly kategorie A1 a A2 Měření časových průběhů napětí, proudu, výkonu a frekvence napětí  proudu  výkonu  frekvence  BZP_07_A (Metodika pro testování nesynchronní komponenty výrobního modulu kategorie A1 a A2) Niesynchroniczne moduly wytworcze kategorii A1 i A2 Pomiar przebiegow czasowych napiecia, pradu, mocy i czestotliwosci Napiecie  Prad  Moc  Czestotliwosc  Nesynchronni vyrobni moduly kategorie A1 a A2 Mereni casovych prubehu napeti, proudu, vykonu a frekvence napeti  proudu  vykonu  frekvence  BZP_07_A (Metodika pro testovani nesynchronni komponenty vyrobniho modulu kategorie A1 a A2)","search_en":"Power Park Modules type A1 and A2 Measurement of Voltage, Current, Power, and Frequency Time Profiles Voltage  Current  Power  Frequency  BZP_07_A (Metodika pro testování nesynchronní komponenty výrobního modulu kategorie A1 a A2)","search_zh":"A1和A2类非同步发电模块 电压、电流、功率和频率时间曲线测量 电压  电流  功率  频率  BZP_07_A (Metodika pro testování nesynchronní komponenty výrobního modulu kategorie A1 a A2)","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}