{"lab":{"_id":"69ad52a4de79e566650fd4f2","country":"CZ","accr_number":"1635","accr_body":"ČIA","address":"Lidická 977, 273 43 Buštěhrad","categories":["pharma","metrology"],"city":"Buštěhrad","imported_at":"2026-03-08T10:42:44.590Z","methods_count":3,"name":"DYNEX TECHNOLOGIES, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1635_10_2026_CS.pdf","1635_10_2026_EN.pdf"],"scope_summary":"Badania komór z przepływem laminarnym wszystkich klas","search_text":"dynex technologies, spol. s r.o. lidická 977, 273 43 buštěhrad 1635","status":"active","updated_at":"2026-03-08T14:52:14.241Z","valid_from":"","valid_until":"07-01-2031","website":"www.dynex.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.dynex.cz","map_coord":[50.153836,14.194421],"map_geo":"nominatim-street","certificate_date":"07.01.2026","certificate_no":"10/2026","certificate_replaces":"48/2021 z 14.01.2021","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania komór z przepływem laminarnym wszystkich klas","en":"Testing of laminar flow cabinets of all classes","zh":"各级层流柜检测","cs":"Zkoušky laminárních boxů všech tříd"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze DYNEX","lab_division_cs":"Zkušební laboratoř DYNEX","lab_division_en":"DYNEX Testing Laboratory","lab_division_zh":"DYNEX检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"IP","pl":"Wewnętrzna procedura badawcza","en":"Internal test procedure","zh":"内部检测程序","cs":"Interní zkušební postup"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"3edd56527705663f2c39faacd2c3e83d4f831d4a572deb7caffece29a673f8cc","source_pdf_url":"https://www.cai.cz/OA/pdf/10_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"64bf82bf3b9a12837a640909","lab_id":"69ad52a4de79e566650fd4f2","country":"CZ","accr_number":"1635","accr_body":"ČIA","row_label":"1","test_object":"Urządzenia i pomieszczenia z laminarnym przepływem powietrza","test_object_en":"Equipment and rooms with laminar air flow","test_object_zh":"层流设备和空间","test_object_cs":"Zařízení a prostory s laminárním prouděním vzduchu","methodology":"Oznaczanie średniej prędkości i równomierności przepływu","methodology_en":"Determination of mean velocity and uniformity of air flow","methodology_zh":"平均气流速度和均匀性测定","methodology_cs":"Stanovení střední rychlosti a rovnoměrnosti proudění","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie średniej prędkości i równomierności przepływu","reference":"IP-03 (ČSN 12 4010:1980; ČSN EN 12469)","norm_bases":["IP-03","ČSN 12 4010:1980","ČSN EN 12469"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia i pomieszczenia z laminarnym przepływem powietrza Oznaczanie średniej prędkości i równomierności przepływu Zařízení a prostory s laminárním prouděním vzduchu Stanovení střední rychlosti a rovnoměrnosti proudění IP-03 (ČSN 12 4010:1980; ČSN EN 12469) Urzadzenia i pomieszczenia z laminarnym przeplywem powietrza Oznaczanie sredniej predkosci i rownomiernosci przeplywu Zarizeni a prostory s laminarnim proudenim vzduchu Stanoveni stredni rychlosti a rovnomernosti proudeni IP-03 (CSN 12 4010:1980; CSN EN 12469)","search_en":"Equipment and rooms with laminar air flow Determination of mean velocity and uniformity of air flow IP-03 (ČSN 12 4010:1980; ČSN EN 12469)","search_zh":"层流设备和空间 平均气流速度和均匀性测定 IP-03 (ČSN 12 4010:1980; ČSN EN 12469)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4af8fc77829e462ffd632af","lab_id":"69ad52a4de79e566650fd4f2","country":"CZ","accr_number":"1635","accr_body":"ČIA","row_label":"2","test_object":"Urządzenia i pomieszczenia z laminarnym przepływem powietrza","test_object_en":"Equipment and rooms with laminar air flow","test_object_zh":"层流设备和空间","test_object_cs":"Zařízení a prostory s laminárním prouděním vzduchu","methodology":"Pomiar liczby cząstek aerozolu w powietrzu i gazach","methodology_en":"Measurement of the number of aerosol particles in air and gases","methodology_zh":"空气和气体中气溶胶粒子计数","methodology_cs":"Měření počtu částic aerosolů ve vzduchu a plynech","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar liczby cząstek aerozolu w powietrzu i gazach","reference":"IP-04 (ČSN EN 1822-1; ČSN EN ISO 14644-1)","norm_bases":["IP-04","ČSN EN 1822-1","ČSN EN ISO 14644-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia i pomieszczenia z laminarnym przepływem powietrza Pomiar liczby cząstek aerozolu w powietrzu i gazach Zařízení a prostory s laminárním prouděním vzduchu Měření počtu částic aerosolů ve vzduchu a plynech IP-04 (ČSN EN 1822-1; ČSN EN ISO 14644-1) Urzadzenia i pomieszczenia z laminarnym przeplywem powietrza Pomiar liczby czastek aerozolu w powietrzu i gazach Zarizeni a prostory s laminarnim proudenim vzduchu Mereni poctu castic aerosolu ve vzduchu a plynech IP-04 (CSN EN 1822-1; CSN EN ISO 14644-1)","search_en":"Equipment and rooms with laminar air flow Measurement of the number of aerosol particles in air and gases IP-04 (ČSN EN 1822-1; ČSN EN ISO 14644-1)","search_zh":"层流设备和空间 空气和气体中气溶胶粒子计数 IP-04 (ČSN EN 1822-1; ČSN EN ISO 14644-1)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4ce688ddd9758a9cfa480a5a","lab_id":"69ad52a4de79e566650fd4f2","country":"CZ","accr_number":"1635","accr_body":"ČIA","row_label":"3","test_object":"Komory z przepływem laminarnym","test_object_en":"Laminar flow cabinets","test_object_zh":"层流柜","test_object_cs":"Boxy s laminárním prouděním","methodology":"Oznaczanie szczelności","methodology_en":"Determination of leak tightness","methodology_zh":"密封性测定","methodology_cs":"Stanovení těsnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda obciążenia aerozolem","technique_en":"Aerosol challenge method","technique_zh":"气溶胶挑战法","technique_cs":"metodou aerosolové zátěže","techniques":["Metoda obciążenia aerozolem"],"techniques_en":["Aerosol challenge method"],"techniques_zh":["气溶胶挑战法"],"techniques_cs":["metodou aerosolové zátěže"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie szczelności\nMetoda obciążenia aerozolem","reference":"IP-05 (ČSN EN 1822-1; ČSN EN ISO 14644-1)","norm_bases":["IP-05","ČSN EN 1822-1","ČSN EN ISO 14644-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Komory z przepływem laminarnym Oznaczanie szczelności Metoda obciążenia aerozolem Boxy s laminárním prouděním Stanovení těsnosti metodou aerosolové zátěže IP-05 (ČSN EN 1822-1; ČSN EN ISO 14644-1) Komory z przeplywem laminarnym Oznaczanie szczelnosci Metoda obciazenia aerozolem Boxy s laminarnim proudenim Stanoveni tesnosti metodou aerosolove zateze IP-05 (CSN EN 1822-1; CSN EN ISO 14644-1)","search_en":"Laminar flow cabinets Determination of leak tightness Aerosol challenge method IP-05 (ČSN EN 1822-1; ČSN EN ISO 14644-1)","search_zh":"层流柜 密封性测定 气溶胶挑战法 IP-05 (ČSN EN 1822-1; ČSN EN ISO 14644-1)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}