{"lab":{"_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","address":"Tiskařská 10/257, 108 00 Praha 10","categories":["construction"],"city":"Praha 10","imported_at":"2026-03-08T10:42:44.590Z","methods_count":7,"name":"DEKPROJEKT s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1565_453_2022_CS.pdf","1565_453_2022_EN.pdf"],"scope_summary":"Pomiary akustyczne, pomiary oświetlenia sztucznego i pomiary przepuszczalności powietrza (test Blower-Door).","search_text":"dekprojekt s.r.o. tiskařská 10/257, 108 00 praha 10 1565","status":"active","updated_at":"2026-03-08T14:52:13.566Z","valid_from":"","valid_until":"20-09-2027","website":"www.atelier-dek.cz","location":{"type":"Point","coordinates":[14.4378,50.0755]},"email_confidence":"low","email_mx":false,"email_source":"https://www.atelier-dek.cz","needs_review":true,"review_reason":"domena bez MX — zweryfikuj","map_coord":[50.082928,14.523169],"map_geo":"nominatim-street","certificate_date":"20.09.2022","certificate_no":"453/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary akustyczne, pomiary oświetlenia sztucznego i pomiary przepuszczalności powietrza (test Blower-Door).","en":"Acoustic measurements, artificial lighting measurements and air permeability measurements (Blower-Door test).","zh":"声学测量、人工照明测量和气密性测量（鼓风门试验）。","cs":"Akustická měření, měření umělého osvětlení a měření průvzdušnosti (Blower-Door test)."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze ATELIER DEK","lab_division_cs":"Zkušební laboratoř ATELIER DEK","lab_division_en":"Testing Laboratory ATELIER DEK","lab_division_zh":"ATELIER DEK检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"Věstník MZ ČR","pl":"Dziennik Urzędowy Ministerstwa Zdrowia Republiki Czeskiej, rocznik 2017, część 11 – Wytyczne metodyczne pomiaru i oceny hałasu w środowisku pozazawodowym","en":"Bulletin of the Ministry of Health of the Czech Republic, 2017, issue 11 – Methodological guideline for measurement and assessment of noise in the non-occupational environment","zh":"捷克卫生部公报2017年第11期 – 非职业环境噪声测量与评价方法指南","cs":"Věstník MZ ČR, Ročník 2017, částka 11 - Metodický návod pro měření a hodnocení hluku v mimopracovním prostředí"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie fachowe i interpretacje wyników badań.","en":"The laboratory provides expert opinions and interpretations of test results.","zh":"实验室提供检测结果的专业意见和解释。","cs":"Laboratoř poskytuje odborná stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"43541984b6ead0e23843903810842414abb89bb756e793a4f807b4dc7a66d8fc","source_pdf_url":"https://www.cai.cz/OA/pdf/P453_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"04f26430cfc8944937cf8ab2","lab_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","row_label":"1","test_object":"Wewnętrzne przegrody działowe i przegrody zewnętrzne w budynkach","test_object_en":"Internal separating and envelope structures in buildings","test_object_zh":"建筑物内部分隔构件及围护结构","test_object_cs":"Vnitřní dělící a obalové konstrukce v budovách","methodology":"Pomiar izolacyjności akustycznej","methodology_en":"Measurement of sound insulation","methodology_zh":"隔声测量","methodology_cs":"Měření zvukové izolace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej","reference":"ČSN EN ISO 16283-1 ČSN EN ISO 16283-2 ČSN EN ISO 16283-3 ČSN EN ISO 717-1 ČSN EN ISO 717-2","norm_bases":["ČSN EN ISO 16283-1","ČSN EN ISO 16283-2","ČSN EN ISO 16283-3","ČSN EN ISO 717-1","ČSN EN ISO 717-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wewnętrzne przegrody działowe i przegrody zewnętrzne w budynkach Pomiar izolacyjności akustycznej Vnitřní dělící a obalové konstrukce v budovách Měření zvukové izolace ČSN EN ISO 16283-1 ČSN EN ISO 16283-2 ČSN EN ISO 16283-3 ČSN EN ISO 717-1 ČSN EN ISO 717-2 Wewnetrzne przegrody dzialowe i przegrody zewnetrzne w budynkach Pomiar izolacyjnosci akustycznej Vnitrni delici a obalove konstrukce v budovach Mereni zvukove izolace CSN EN ISO 16283-1 CSN EN ISO 16283-2 CSN EN ISO 16283-3 CSN EN ISO 717-1 CSN EN ISO 717-2","search_en":"Internal separating and envelope structures in buildings Measurement of sound insulation ČSN EN ISO 16283-1 ČSN EN ISO 16283-2 ČSN EN ISO 16283-3 ČSN EN ISO 717-1 ČSN EN ISO 717-2","search_zh":"建筑物内部分隔构件及围护结构 隔声测量 ČSN EN ISO 16283-1 ČSN EN ISO 16283-2 ČSN EN ISO 16283-3 ČSN EN ISO 717-1 ČSN EN ISO 717-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e56670f20206f52dce836c52","lab_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","row_label":"2","test_object":"Pomieszczenia w budynkach","test_object_en":"Rooms in buildings","test_object_zh":"建筑物内房间","test_object_cs":"Místnosti v budovách","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN EN ISO 3382-2","norm_bases":["ČSN EN ISO 3382-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia w budynkach Pomiar czasu pogłosu Místnosti v budovách Měření doby dozvuku ČSN EN ISO 3382-2 Pomieszczenia w budynkach Pomiar czasu poglosu Mistnosti v budovach Mereni doby dozvuku CSN EN ISO 3382-2","search_en":"Rooms in buildings Measurement of reverberation time ČSN EN ISO 3382-2","search_zh":"建筑物内房间 混响时间测量 ČSN EN ISO 3382-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9c7fd26e34a0b0a0d6980b3","lab_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","row_label":"3","test_object":"Środowisko pozazawodowe","test_object_en":"Non-occupational environment","test_object_zh":"非职业环境","test_object_cs":"Mimopracovní prostředí","methodology":"Pomiar hałasu","methodology_en":"Noise measurement","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"ČSN ISO 1996-1 ČSN ISO 1996-2 ČSN EN ISO 16032 Věstník MZ ČR, částka 11/2017","norm_bases":["ČSN ISO 1996-1","ČSN ISO 1996-2","ČSN EN ISO 16032","Věstník MZ ČR, částka 11/2017"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pozazawodowe Pomiar hałasu Mimopracovní prostředí Měření hluku ČSN ISO 1996-1 ČSN ISO 1996-2 ČSN EN ISO 16032 Věstník MZ ČR, částka 11/2017 Srodowisko pozazawodowe Pomiar halasu Mimopracovni prostredi Mereni hluku CSN ISO 1996-1 CSN ISO 1996-2 CSN EN ISO 16032 Vestnik MZ CR, castka 11/2017","search_en":"Non-occupational environment Noise measurement ČSN ISO 1996-1 ČSN ISO 1996-2 ČSN EN ISO 16032 Věstník MZ ČR, částka 11/2017","search_zh":"非职业环境 噪声测量 ČSN ISO 1996-1 ČSN ISO 1996-2 ČSN EN ISO 16032 Věstník MZ ČR, částka 11/2017","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4562dad48cba9345b61c3ce4","lab_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","row_label":"4","test_object":"Przegrody zewnętrzne budynków","test_object_en":"Building envelope structures","test_object_zh":"建筑围护结构","test_object_cs":"Obalové konstrukce budov","methodology":"Pomiar przepuszczalności powietrza","methodology_en":"Measurement of air permeability","methodology_zh":"气密性测量","methodology_cs":"Měření průvzdušnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Test Blower-Door (metoda ciśnieniowa z wentylatorem)","technique_en":"Blower-Door test (fan pressurization method)","technique_zh":"鼓风门试验（风机加压法）","technique_cs":"Blower-Door test","techniques":["Test Blower-Door (metoda ciśnieniowa z wentylatorem)"],"techniques_en":["Blower-Door test (fan pressurization method)"],"techniques_zh":["鼓风门试验（风机加压法）"],"techniques_cs":["Blower-Door test"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar przepuszczalności powietrza\nTest Blower-Door (metoda ciśnieniowa z wentylatorem)","reference":"ČSN EN ISO 9972","norm_bases":["ČSN EN ISO 9972"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody zewnętrzne budynków Pomiar przepuszczalności powietrza Test Blower-Door (metoda ciśnieniowa z wentylatorem) Obalové konstrukce budov Měření průvzdušnosti Blower-Door test ČSN EN ISO 9972 Przegrody zewnetrzne budynkow Pomiar przepuszczalnosci powietrza Test Blower-Door (metoda cisnieniowa z wentylatorem) Obalove konstrukce budov Mereni pruvzdusnosti Blower-Door test CSN EN ISO 9972","search_en":"Building envelope structures Measurement of air permeability Blower-Door test (fan pressurization method) ČSN EN ISO 9972","search_zh":"建筑围护结构 气密性测量 鼓风门试验（风机加压法） ČSN EN ISO 9972","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f00da589021a5882b12454d6","lab_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","row_label":"5","test_object":"Przestrzenie wewnętrzne","test_object_en":"Indoor spaces","test_object_zh":"室内空间","test_object_cs":"Vnitřní prostory","methodology":"Pomiar oświetlenia sztucznego","methodology_en":"Measurement of artificial lighting","methodology_zh":"人工照明测量","methodology_cs":"Měření umělého osvětlení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar oświetlenia sztucznego","reference":"ČSN 36 0011-1, ČSN 36 0011-3","norm_bases":["ČSN 36 0011-1","ČSN 36 0011-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przestrzenie wewnętrzne Pomiar oświetlenia sztucznego Vnitřní prostory Měření umělého osvětlení ČSN 36 0011-1, ČSN 36 0011-3 Przestrzenie wewnetrzne Pomiar oswietlenia sztucznego Vnitrni prostory Mereni umeleho osvetleni CSN 36 0011-1, CSN 36 0011-3","search_en":"Indoor spaces Measurement of artificial lighting ČSN 36 0011-1, ČSN 36 0011-3","search_zh":"室内空间 人工照明测量 ČSN 36 0011-1, ČSN 36 0011-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22f797474f639bde420aaf45","lab_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","row_label":"6","test_object":"Drogi","test_object_en":"Roads","test_object_zh":"道路","test_object_cs":"Pozemní komunikace","methodology":"Pomiar oświetlenia sztucznego","methodology_en":"Measurement of artificial lighting","methodology_zh":"人工照明测量","methodology_cs":"Měření umělého osvětlení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar oświetlenia sztucznego","reference":"ČSN EN 13201-4","norm_bases":["ČSN EN 13201-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Drogi Pomiar oświetlenia sztucznego Pozemní komunikace Měření umělého osvětlení ČSN EN 13201-4 Drogi Pomiar oswietlenia sztucznego Pozemni komunikace Mereni umeleho osvetleni CSN EN 13201-4","search_en":"Roads Measurement of artificial lighting ČSN EN 13201-4","search_zh":"道路 人工照明测量 ČSN EN 13201-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1968965be85c832dbed5b84","lab_id":"69ad52a4de79e566650fd4a0","country":"CZ","accr_number":"1565","accr_body":"ČIA","row_label":"7","test_object":"Przestrzenie zewnętrzne","test_object_en":"Outdoor spaces","test_object_zh":"室外空间","test_object_cs":"Venkovní prostory","methodology":"Pomiar oświetlenia sztucznego","methodology_en":"Measurement of artificial lighting","methodology_zh":"人工照明测量","methodology_cs":"Měření umělého osvětlení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar oświetlenia sztucznego","reference":"ČSN 36 0011-1, ČSN 36 0011-4","norm_bases":["ČSN 36 0011-1","ČSN 36 0011-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przestrzenie zewnętrzne Pomiar oświetlenia sztucznego Venkovní prostory Měření umělého osvětlení ČSN 36 0011-1, ČSN 36 0011-4 Przestrzenie zewnetrzne Pomiar oswietlenia sztucznego Venkovni prostory Mereni umeleho osvetleni CSN 36 0011-1, CSN 36 0011-4","search_en":"Outdoor spaces Measurement of artificial lighting ČSN 36 0011-1, ČSN 36 0011-4","search_zh":"室外空间 人工照明测量 ČSN 36 0011-1, ČSN 36 0011-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}