{"lab":{"_id":"69ad52a4de79e566650fd460","accr_number":"1517","country":"CZ","accr_body":"ČIA","address":"Erbenova 146/10, 460 08 Liberec 8","categories":["environment","construction"],"city":"Liberec 8","imported_at":"2026-03-08T10:42:44.590Z","methods_count":14,"name":"BERYL, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1517_50_2026_CS.pdf","1517_50_2026_EN.pdf"],"scope_summary":"Badania fizyczne i chemiczne w środowisku pracy i poza środowiskiem pracy","search_text":"beryl, spol. s r.o. erbenova 146/10, 460 08 liberec 8 1517","status":"active","updated_at":"2026-03-08T14:52:13.236Z","valid_from":"","valid_until":"28-01-2031","website":"www.beryl-lbc.cz","location":{"type":"Point","coordinates":[15.0543,50.7663]},"email_confidence":"low","email_mx":true,"email_source":"https://www.beryl-lbc.cz","needs_review":true,"review_reason":"e-mail ze strony (domena inna niż WWW) — zweryfikuj","certificate_date":"28.01.2026","certificate_no":"50/2026","certificate_replaces":"621/2024 z 21.11.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania fizyczne i chemiczne w środowisku pracy i poza środowiskiem pracy","en":"Physical and chemical tests in the working and non-working environment","zh":"工作环境和非工作环境中的物理和化学检测","cs":"Fyzikální a chemické zkoušky v pracovním a mimopracovním prostředí"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Czynników Fizycznych i Chemicznych","lab_division_cs":"Laboratoř fyzikálních a chemických faktorů","lab_division_en":"Laboratory of Physical and Chemical Factors","lab_division_zh":"物理和化学因素实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"SOP B_LBC","pl":"Standardowa procedura operacyjna","en":"Standard operating procedure","zh":"标准操作程序","cs":"Standardní operační postup"},{"abbr":"OSHA","pl":"Occupational Safety and Health Administration (amerykański urząd BHP)","en":"Occupational Safety and Health Administration","zh":"美国职业安全与健康管理局","cs":"Occupational Safety and Health Administration"},{"abbr":"PUF","pl":"Pianka poliuretanowa","en":"Polyurethane foam","zh":"聚氨酯泡沫","cs":"Polyuretanová pěna"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is competent to carry out standalone sampling.","zh":"实验室有能力独立进行采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"76331fd2fc2f599ed1f51605ae3c7cbbdc6b8c9d0db79733a6aa9f30be71ccf1","source_pdf_url":"https://www.cai.cz/OA/pdf/50_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"82c28c47f7ce2bc7fc6ad49b","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"1","test_object":"Środowisko pracy","test_object_en":"Working environment","test_object_zh":"工作环境","test_object_cs":"Pracovní prostředí","methodology":"Pomiar hałasu","methodology_en":"Noise measurement","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"SOP B_LBC 3 (ČSN EN ISO 9612; ČSN ISO 1999; Věstník MZ ČR částka 4/2013)","norm_bases":["SOP B_LBC 3","ČSN EN ISO 9612","ČSN ISO 1999","Věstník MZ ČR částka 4/2013"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pracy Pomiar hałasu Pracovní prostředí Měření hluku SOP B_LBC 3 (ČSN EN ISO 9612; ČSN ISO 1999; Věstník MZ ČR částka 4/2013) Srodowisko pracy Pomiar halasu Pracovni prostredi Mereni hluku SOP B_LBC 3 (CSN EN ISO 9612; CSN ISO 1999; Vestnik MZ CR castka 4/2013)","search_en":"Working environment Noise measurement SOP B_LBC 3 (ČSN EN ISO 9612; ČSN ISO 1999; Věstník MZ ČR částka 4/2013)","search_zh":"工作环境 噪声测量 SOP B_LBC 3 (ČSN EN ISO 9612; ČSN ISO 1999; Věstník MZ ČR částka 4/2013)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4bc51944994ebb8e66c21184","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"2","test_object":"Środowisko poza miejscem pracy","test_object_en":"Non-working environment","test_object_zh":"非工作环境","test_object_cs":"Mimopracovní prostředí","methodology":"Pomiar hałasu","methodology_en":"Noise measurement","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"SOP B_LBC 4 (ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR částka 14/2023)","norm_bases":["SOP B_LBC 4","ČSN ISO 1996-1","ČSN ISO 1996-2","Věstník MZ ČR částka 14/2023"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko poza miejscem pracy Pomiar hałasu Mimopracovní prostředí Měření hluku SOP B_LBC 4 (ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR částka 14/2023) Srodowisko poza miejscem pracy Pomiar halasu Mimopracovni prostredi Mereni hluku SOP B_LBC 4 (CSN ISO 1996-1; CSN ISO 1996-2; Vestnik MZ CR castka 14/2023)","search_en":"Non-working environment Noise measurement SOP B_LBC 4 (ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR částka 14/2023)","search_zh":"非工作环境 噪声测量 SOP B_LBC 4 (ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR částka 14/2023)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a8037026d3066612936fd2c2","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"3","test_object":"Środowisko pracy i poza miejscem pracy","test_object_en":"Working and non-working environment","test_object_zh":"工作环境和非工作环境","test_object_cs":"Pracovní a mimopracovní prostředí","methodology":"Pomiar drgań","methodology_en":"Vibration measurement","methodology_zh":"振动测量","methodology_cs":"Měření vibrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar drgań","reference":"SOP B_LBC 5 (ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN ISO 2631-1; ČSN ISO 2631-2; Věstník MZ ČR částka 4/2013)","norm_bases":["SOP B_LBC 5","ČSN EN ISO 5349-1","ČSN EN ISO 5349-2","ČSN ISO 2631-1","ČSN ISO 2631-2","Věstník MZ ČR částka 4/2013"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pracy i poza miejscem pracy Pomiar drgań Pracovní a mimopracovní prostředí Měření vibrací SOP B_LBC 5 (ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN ISO 2631-1; ČSN ISO 2631-2; Věstník MZ ČR částka 4/2013) Srodowisko pracy i poza miejscem pracy Pomiar drgan Pracovni a mimopracovni prostredi Mereni vibraci SOP B_LBC 5 (CSN EN ISO 5349-1; CSN EN ISO 5349-2; CSN ISO 2631-1; CSN ISO 2631-2; Vestnik MZ CR castka 4/2013)","search_en":"Working and non-working environment Vibration measurement SOP B_LBC 5 (ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN ISO 2631-1; ČSN ISO 2631-2; Věstník MZ ČR částka 4/2013)","search_zh":"工作环境和非工作环境 振动测量 SOP B_LBC 5 (ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN ISO 2631-1; ČSN ISO 2631-2; Věstník MZ ČR částka 4/2013)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1398c4a9bc7b019e9c699493","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"4","test_object":"Przegrody wewnętrzne (stropy, ściany i wypełnienia otworów)","test_object_en":"Separating structures (ceilings, walls and opening fillings)","test_object_zh":"分隔构件（楼板、墙体和门窗洞口填充物）","test_object_cs":"Dělicí konstrukce (stropy, stěny a výplně otvorů)","methodology":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","methodology_en":"Measurement of sound insulation – airborne sound insulation","methodology_zh":"空气声隔声测量","methodology_cs":"Měření zvukové izolace – vzduchová neprůzvučnost","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","reference":"SOP B_LBC 6 (ČSN EN ISO 16283-1; ČSN EN ISO 717-1)","norm_bases":["SOP B_LBC 6","ČSN EN ISO 16283-1","ČSN EN ISO 717-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody wewnętrzne (stropy, ściany i wypełnienia otworów) Pomiar izolacyjności akustycznej od dźwięków powietrznych Dělicí konstrukce (stropy, stěny a výplně otvorů) Měření zvukové izolace – vzduchová neprůzvučnost SOP B_LBC 6 (ČSN EN ISO 16283-1; ČSN EN ISO 717-1) Przegrody wewnetrzne (stropy, sciany i wypelnienia otworow) Pomiar izolacyjnosci akustycznej od dzwiekow powietrznych Delici konstrukce (stropy, steny a vyplne otvoru) Mereni zvukove izolace – vzduchova nepruzvucnost SOP B_LBC 6 (CSN EN ISO 16283-1; CSN EN ISO 717-1)","search_en":"Separating structures (ceilings, walls and opening fillings) Measurement of sound insulation – airborne sound insulation SOP B_LBC 6 (ČSN EN ISO 16283-1; ČSN EN ISO 717-1)","search_zh":"分隔构件（楼板、墙体和门窗洞口填充物） 空气声隔声测量 SOP B_LBC 6 (ČSN EN ISO 16283-1; ČSN EN ISO 717-1)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b75100016964ad3174377a0f","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"5","test_object":"Przegrody wewnętrzne","test_object_en":"Separating structures","test_object_zh":"分隔构件","test_object_cs":"Dělicí konstrukce","methodology":"Pomiar izolacyjności akustycznej od dźwięków uderzeniowych","methodology_en":"Measurement of sound insulation – impact sound insulation","methodology_zh":"撞击声隔声测量","methodology_cs":"Měření zvukové izolace – kročejová neprůzvučnost","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej od dźwięków uderzeniowych","reference":"SOP B_LBC 6 (ČSN EN ISO 16283-2; ČSN EN ISO 717-2)","norm_bases":["SOP B_LBC 6","ČSN EN ISO 16283-2","ČSN EN ISO 717-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody wewnętrzne Pomiar izolacyjności akustycznej od dźwięków uderzeniowych Dělicí konstrukce Měření zvukové izolace – kročejová neprůzvučnost SOP B_LBC 6 (ČSN EN ISO 16283-2; ČSN EN ISO 717-2) Przegrody wewnetrzne Pomiar izolacyjnosci akustycznej od dzwiekow uderzeniowych Delici konstrukce Mereni zvukove izolace – krocejova nepruzvucnost SOP B_LBC 6 (CSN EN ISO 16283-2; CSN EN ISO 717-2)","search_en":"Separating structures Measurement of sound insulation – impact sound insulation SOP B_LBC 6 (ČSN EN ISO 16283-2; ČSN EN ISO 717-2)","search_zh":"分隔构件 撞击声隔声测量 SOP B_LBC 6 (ČSN EN ISO 16283-2; ČSN EN ISO 717-2)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d7bb88107a211b72f796b69","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"6","test_object":"Przegrody zewnętrzne (obudowy) konstrukcji i budynków","test_object_en":"External envelopes of structures and buildings","test_object_zh":"构筑物和建筑物的外围护结构","test_object_cs":"Obvodové pláště konstrukcí a budov","methodology":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","methodology_en":"Measurement of sound insulation – airborne sound insulation","methodology_zh":"空气声隔声测量","methodology_cs":"Měření zvukové izolace – vzduchová neprůzvučnost","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","reference":"SOP B_LBC 6 (ČSN EN ISO 16283-3; ČSN EN ISO 717-1)","norm_bases":["SOP B_LBC 6","ČSN EN ISO 16283-3","ČSN EN ISO 717-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody zewnętrzne (obudowy) konstrukcji i budynków Pomiar izolacyjności akustycznej od dźwięków powietrznych Obvodové pláště konstrukcí a budov Měření zvukové izolace – vzduchová neprůzvučnost SOP B_LBC 6 (ČSN EN ISO 16283-3; ČSN EN ISO 717-1) Przegrody zewnetrzne (obudowy) konstrukcji i budynkow Pomiar izolacyjnosci akustycznej od dzwiekow powietrznych Obvodove plaste konstrukci a budov Mereni zvukove izolace – vzduchova nepruzvucnost SOP B_LBC 6 (CSN EN ISO 16283-3; CSN EN ISO 717-1)","search_en":"External envelopes of structures and buildings Measurement of sound insulation – airborne sound insulation SOP B_LBC 6 (ČSN EN ISO 16283-3; ČSN EN ISO 717-1)","search_zh":"构筑物和建筑物的外围护结构 空气声隔声测量 SOP B_LBC 6 (ČSN EN ISO 16283-3; ČSN EN ISO 717-1)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4bd8444fca77ebc8aa2dcebb","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"7","test_object":"Pomieszczenia do wykonywania muzyki i mowy","test_object_en":"Spaces for music and speech performance","test_object_zh":"音乐和语言表演空间","test_object_cs":"Prostory pro přednes hudby a řeči","methodology":"Pomiar czasu pogłosu","methodology_en":"Reverberation time measurement","methodology_zh":"混响时间测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"SOP B_LBC 7 (ČSN EN ISO 3382-1)","norm_bases":["SOP B_LBC 7","ČSN EN ISO 3382-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia do wykonywania muzyki i mowy Pomiar czasu pogłosu Prostory pro přednes hudby a řeči Měření doby dozvuku SOP B_LBC 7 (ČSN EN ISO 3382-1) Pomieszczenia do wykonywania muzyki i mowy Pomiar czasu poglosu Prostory pro prednes hudby a reci Mereni doby dozvuku SOP B_LBC 7 (CSN EN ISO 3382-1)","search_en":"Spaces for music and speech performance Reverberation time measurement SOP B_LBC 7 (ČSN EN ISO 3382-1)","search_zh":"音乐和语言表演空间 混响时间测量 SOP B_LBC 7 (ČSN EN ISO 3382-1)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19158d93126fda4c755a006d","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"8","test_object":"Pomieszczenia zwykłe","test_object_en":"Ordinary rooms","test_object_zh":"普通房间","test_object_cs":"Běžné prostory","methodology":"Pomiar czasu pogłosu","methodology_en":"Reverberation time measurement","methodology_zh":"混响时间测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"SOP B_LBC 7 (ČSN EN ISO 3382-2)","norm_bases":["SOP B_LBC 7","ČSN EN ISO 3382-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia zwykłe Pomiar czasu pogłosu Běžné prostory Měření doby dozvuku SOP B_LBC 7 (ČSN EN ISO 3382-2) Pomieszczenia zwykle Pomiar czasu poglosu Bezne prostory Mereni doby dozvuku SOP B_LBC 7 (CSN EN ISO 3382-2)","search_en":"Ordinary rooms Reverberation time measurement SOP B_LBC 7 (ČSN EN ISO 3382-2)","search_zh":"普通房间 混响时间测量 SOP B_LBC 7 (ČSN EN ISO 3382-2)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e85eb78668d305029b0556e8","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"9","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Oznaczanie stężenia pyłu (frakcja wdychalna i respirabilna)","methodology_en":"Determination of dust concentration (total and respirable fraction)","methodology_zh":"粉尘浓度测定（总粉尘和呼吸性粉尘）","methodology_cs":"Stanovení koncentrace prachu (celková a respirabilní frakce)","parameters":[{"name":"Frakcja całkowita (wdychalna)","range":""},{"name":"Frakcja respirabilna","range":""}],"parameters_en":[{"name":"Total fraction","range":""},{"name":"Respirable fraction","range":""}],"parameters_zh":[{"name":"总粉尘","range":""},{"name":"呼吸性粉尘","range":""}],"parameters_cs":[{"name":"celková frakce","range":""},{"name":"respirabilní frakce","range":""}],"technique":"Metoda wagowa","technique_en":"Gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia pyłu (frakcja wdychalna i respirabilna)\nZakres:\nFrakcja całkowita (wdychalna)\nFrakcja respirabilna\nMetoda wagowa","reference":"SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., příloha 3)","norm_bases":["SOP B_LBC 1, část 8–12","Nařízení vlády č. 361/2007 Sb., příloha 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie stężenia pyłu (frakcja wdychalna i respirabilna) Metoda wagowa Frakcja całkowita (wdychalna)  Frakcja respirabilna  Pracovní ovzduší Stanovení koncentrace prachu (celková a respirabilní frakce) gravimetricky celková frakce  respirabilní frakce  SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., příloha 3) Powietrze na stanowiskach pracy Oznaczanie stezenia pylu (frakcja wdychalna i respirabilna) Metoda wagowa Frakcja calkowita (wdychalna)  Frakcja respirabilna  Pracovni ovzdusi Stanoveni koncentrace prachu (celkova a respirabilni frakce) gravimetricky celkova frakce  respirabilni frakce  SOP B_LBC 1, cast 8–12 (Narizeni vlady c. 361/2007 Sb., priloha 3)","search_en":"Workplace air Determination of dust concentration (total and respirable fraction) Gravimetry Total fraction  Respirable fraction  SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., příloha 3)","search_zh":"工作场所空气 粉尘浓度测定（总粉尘和呼吸性粉尘） 重量法 总粉尘  呼吸性粉尘  SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., příloha 3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8d9b53350b65098f843fb30e","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"10","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Oznaczanie stężenia liczbowego włókien mineralnych","methodology_en":"Determination of number concentration of mineral fibres","methodology_zh":"矿物纤维数量浓度测定","methodology_cs":"Stanovení početní koncentrace minerálních vláken","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Obliczenie na podstawie zmierzonych wartości","technique_en":"Calculation from measured values","technique_zh":"根据测定值计算","technique_cs":"výpočtem z naměřených hodnot","techniques":["Obliczenie na podstawie zmierzonych wartości"],"techniques_en":["Calculation from measured values"],"techniques_zh":["根据测定值计算"],"techniques_cs":["výpočtem z naměřených hodnot"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia liczbowego włókien mineralnych\nObliczenie na podstawie zmierzonych wartości","reference":"SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3)","norm_bases":["SOP B_LBC 1, část 8–12","Nařízení vlády č. 361/2007 Sb., přílohy 2, 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny wykonawca badania w zakresie swojej akredytacji.","note_en":"Laboratory determination of the analytes in the collected sample is performed by an external test provider within the scope of its accreditation.","note_zh":"所采集样品中分析物的实验室测定由外部检测机构在其认可范围内进行。","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Powietrze na stanowiskach pracy Oznaczanie stężenia liczbowego włókien mineralnych Obliczenie na podstawie zmierzonych wartości Pracovní ovzduší Stanovení početní koncentrace minerálních vláken výpočtem z naměřených hodnot SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3) Powietrze na stanowiskach pracy Oznaczanie stezenia liczbowego wlokien mineralnych Obliczenie na podstawie zmierzonych wartosci Pracovni ovzdusi Stanoveni pocetni koncentrace mineralnich vlaken vypoctem z namerenych hodnot SOP B_LBC 1, cast 8–12 (Narizeni vlady c. 361/2007 Sb., prilohy 2, 3)","search_en":"Workplace air Determination of number concentration of mineral fibres Calculation from measured values SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3)","search_zh":"工作场所空气 矿物纤维数量浓度测定 根据测定值计算 SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb5e000e6dcc313964c383c6","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"11","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Oznaczanie stężenia masowego metali","methodology_en":"Determination of mass concentration of metals","methodology_zh":"金属质量浓度测定","methodology_cs":"Stanovení hmotnostní koncentrace kovů","parameters":[{"name":"Metale według rozporządzenia rządu Republiki Czeskiej nr 361/2007 Sb., załącznik 2, 3","range":""}],"parameters_en":[{"name":"Metals according to Government Regulation No. 361/2007 Coll., Annex 2, 3","range":""}],"parameters_zh":[{"name":"金属（依据捷克政府第361/2007号条例附件2、3）","range":""}],"parameters_cs":[{"name":"Kovy dle Nařízení vlády č. 361/2007 Sb., příloha 2, 3","range":""}],"technique":"Obliczenie na podstawie zmierzonych wartości","technique_en":"Calculation from measured values","technique_zh":"根据测定值计算","technique_cs":"výpočtem z naměřených hodnot","techniques":["Obliczenie na podstawie zmierzonych wartości"],"techniques_en":["Calculation from measured values"],"techniques_zh":["根据测定值计算"],"techniques_cs":["výpočtem z naměřených hodnot"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego metali\nMetale według rozporządzenia rządu Republiki Czeskiej nr 361/2007 Sb., załącznik 2, 3\nObliczenie na podstawie zmierzonych wartości","reference":"SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3)","norm_bases":["SOP B_LBC 1, část 8–12","Nařízení vlády č. 361/2007 Sb., přílohy 2, 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny wykonawca badania w zakresie swojej akredytacji.","note_en":"Laboratory determination of the analytes in the collected sample is performed by an external test provider within the scope of its accreditation.","note_zh":"所采集样品中分析物的实验室测定由外部检测机构在其认可范围内进行。","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Powietrze na stanowiskach pracy Oznaczanie stężenia masowego metali Obliczenie na podstawie zmierzonych wartości Metale według rozporządzenia rządu Republiki Czeskiej nr 361/2007 Sb., załącznik 2, 3  Pracovní ovzduší Stanovení hmotnostní koncentrace kovů výpočtem z naměřených hodnot Kovy dle Nařízení vlády č. 361/2007 Sb., příloha 2, 3  SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3) Powietrze na stanowiskach pracy Oznaczanie stezenia masowego metali Obliczenie na podstawie zmierzonych wartosci Metale wedlug rozporzadzenia rzadu Republiki Czeskiej nr 361/2007 Sb., zalacznik 2, 3  Pracovni ovzdusi Stanoveni hmotnostni koncentrace kovu vypoctem z namerenych hodnot Kovy dle Narizeni vlady c. 361/2007 Sb., priloha 2, 3  SOP B_LBC 1, cast 8–12 (Narizeni vlady c. 361/2007 Sb., prilohy 2, 3)","search_en":"Workplace air Determination of mass concentration of metals Calculation from measured values Metals according to Government Regulation No. 361/2007 Coll., Annex 2, 3  SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3)","search_zh":"工作场所空气 金属质量浓度测定 根据测定值计算 金属（依据捷克政府第361/2007号条例附件2、3）  SOP B_LBC 1, část 8–12 (Nařízení vlády č. 361/2007 Sb., přílohy 2, 3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bf7dab452ab32eb5f2066d53","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"12","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Oznaczanie stężenia masowego substancji chemicznych","methodology_en":"Determination of mass concentration of chemical substances","methodology_zh":"化学物质质量浓度测定","methodology_cs":"Stanovení hmotnostní koncentrace chemických látek","parameters":[{"name":"Lotne związki organiczne","range":""},{"name":"Izocyjaniany","range":""},{"name":"Kwasy mineralne","range":""},{"name":"Ozon","range":""}],"parameters_en":[{"name":"Volatile organic compounds","range":""},{"name":"Isocyanates","range":""},{"name":"Mineral acids","range":""},{"name":"Ozone","range":""}],"parameters_zh":[{"name":"挥发性有机物","range":""},{"name":"异氰酸酯","range":""},{"name":"无机酸","range":""},{"name":"臭氧","range":""}],"parameters_cs":[{"name":"těkavé organické látky","range":""},{"name":"isokyanáty","range":""},{"name":"minerální kyseliny","range":""},{"name":"ozón","range":""}],"technique":"Obliczenie na podstawie zmierzonych wartości","technique_en":"Calculation from measured values","technique_zh":"根据测定值计算","technique_cs":"výpočtem z naměřených hodnot","techniques":["Obliczenie na podstawie zmierzonych wartości"],"techniques_en":["Calculation from measured values"],"techniques_zh":["根据测定值计算"],"techniques_cs":["výpočtem z naměřených hodnot"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego substancji chemicznych\nZakres:\nLotne związki organiczne\nIzocyjaniany\nKwasy mineralne\nOzon\nObliczenie na podstawie zmierzonych wartości","reference":"SOP B_LBC 2, část 9–12 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; Nařízení vlády č. 361/2007 Sb., příloha 2)","norm_bases":["SOP B_LBC 2, část 9–12","ČSN EN 482","ČSN EN 689+AC","ČSN EN ISO 16017-1","Nařízení vlády č. 361/2007 Sb., příloha 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Substancje chemiczne według rozporządzenia rządu Republiki Czeskiej nr 361/2007 Sb., załącznik 2. Laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny wykonawca badania w zakresie swojej akredytacji.","note_en":"Chemical substances according to Government Regulation No. 361/2007 Coll., Annex 2. Laboratory determination of the analytes in the collected sample is performed by an external test provider within the scope of its accreditation.","note_zh":"化学物质依据捷克政府第361/2007号条例附件2。所采集样品中分析物的实验室测定由外部检测机构在其认可范围内进行。","note_cs":"Chemické látky dle Nařízení vlády č. 361/2007 Sb., příloha 2; laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Powietrze na stanowiskach pracy Oznaczanie stężenia masowego substancji chemicznych Obliczenie na podstawie zmierzonych wartości Lotne związki organiczne  Izocyjaniany  Kwasy mineralne  Ozon  Pracovní ovzduší Stanovení hmotnostní koncentrace chemických látek výpočtem z naměřených hodnot těkavé organické látky  isokyanáty  minerální kyseliny  ozón  SOP B_LBC 2, část 9–12 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; Nařízení vlády č. 361/2007 Sb., příloha 2) Powietrze na stanowiskach pracy Oznaczanie stezenia masowego substancji chemicznych Obliczenie na podstawie zmierzonych wartosci Lotne zwiazki organiczne  Izocyjaniany  Kwasy mineralne  Ozon  Pracovni ovzdusi Stanoveni hmotnostni koncentrace chemickych latek vypoctem z namerenych hodnot tekave organicke latky  isokyanaty  mineralni kyseliny  ozon  SOP B_LBC 2, cast 9–12 (CSN EN 482; CSN EN 689+AC; CSN EN ISO 16017-1; Narizeni vlady c. 361/2007 Sb., priloha 2)","search_en":"Workplace air Determination of mass concentration of chemical substances Calculation from measured values Volatile organic compounds  Isocyanates  Mineral acids  Ozone  SOP B_LBC 2, část 9–12 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; Nařízení vlády č. 361/2007 Sb., příloha 2)","search_zh":"工作场所空气 化学物质质量浓度测定 根据测定值计算 挥发性有机物  异氰酸酯  无机酸  臭氧  SOP B_LBC 2, část 9–12 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; Nařízení vlády č. 361/2007 Sb., příloha 2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9e44a1e22745106a23c4b83e","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"1","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Pobieranie próbek gazów, par i aerozoli","methodology_en":"Sampling of gases, vapours and aerosols","methodology_zh":"气体、蒸气和气溶胶采样","methodology_cs":"Odběr vzorků plynů, par a aerosolů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Filtr, filtr + PUF, filtr + sorbent, sorbent stały i roztwór absorpcyjny","technique_en":"Filter, filter + PUF, filter + sorbent, solid sorbent and absorption solution","technique_zh":"滤膜、滤膜+聚氨酯泡沫、滤膜+吸附剂、固体吸附剂及吸收液","technique_cs":"filtr, filtr + PUF, filtr + sorbent, pevný sorbent a absorpční roztok","techniques":["Filtr, filtr + PUF, filtr + sorbent, sorbent stały i roztwór absorpcyjny"],"techniques_en":["Filter, filter + PUF, filter + sorbent, solid sorbent and absorption solution"],"techniques_zh":["滤膜、滤膜+聚氨酯泡沫、滤膜+吸附剂、固体吸附剂及吸收液"],"techniques_cs":["filtr, filtr + PUF, filtr + sorbent, pevný sorbent a absorpční roztok"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gazów, par i aerozoli\nFiltr, filtr + PUF, filtr + sorbent, sorbent stały i roztwór absorpcyjny","reference":"SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC); SOP B_LBC 2, část 1-8 (ČSN EN 482; ČSN EN 689+AC; OSHA 42; OSHA 47; OSHA ID-214)","norm_bases":["SOP B_LBC 1, část 1-8","Nařízení vlády č. 361/2007 Sb., příloha 3","ČSN EN ISO 10882-1","ČSN EN 482","ČSN EN 689+AC","SOP B_LBC 2, část 1-8","OSHA 42","OSHA 47","OSHA ID-214"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Pobieranie próbek gazów, par i aerozoli Filtr, filtr + PUF, filtr + sorbent, sorbent stały i roztwór absorpcyjny Pracovní ovzduší Odběr vzorků plynů, par a aerosolů filtr, filtr + PUF, filtr + sorbent, pevný sorbent a absorpční roztok SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC); SOP B_LBC 2, část 1-8 (ČSN EN 482; ČSN EN 689+AC; OSHA 42; OSHA 47; OSHA ID-214) Powietrze na stanowiskach pracy Pobieranie probek gazow, par i aerozoli Filtr, filtr + PUF, filtr + sorbent, sorbent staly i roztwor absorpcyjny Pracovni ovzdusi Odber vzorku plynu, par a aerosolu filtr, filtr + PUF, filtr + sorbent, pevny sorbent a absorpcni roztok SOP B_LBC 1, cast 1-8 (Narizeni vlady c. 361/2007 Sb., priloha 3; CSN EN ISO 10882-1; CSN EN 482; CSN EN 689+AC); SOP B_LBC 2, cast 1-8 (CSN EN 482; CSN EN 689+AC; OSHA 42; OSHA 47; OSHA ID-214)","search_en":"Workplace air Sampling of gases, vapours and aerosols Filter, filter + PUF, filter + sorbent, solid sorbent and absorption solution SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC); SOP B_LBC 2, část 1-8 (ČSN EN 482; ČSN EN 689+AC; OSHA 42; OSHA 47; OSHA ID-214)","search_zh":"工作场所空气 气体、蒸气和气溶胶采样 滤膜、滤膜+聚氨酯泡沫、滤膜+吸附剂、固体吸附剂及吸收液 SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC); SOP B_LBC 2, část 1-8 (ČSN EN 482; ČSN EN 689+AC; OSHA 42; OSHA 47; OSHA ID-214)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac902949c9630e6c3eb16199","lab_id":"69ad52a4de79e566650fd460","country":"CZ","accr_number":"1517","accr_body":"ČIA","row_label":"2","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Pobieranie próbek pyłu (frakcja wdychalna i respirabilna) oraz włókien mineralnych","methodology_en":"Sampling of dust (total and respirable fraction) and mineral fibres","methodology_zh":"粉尘（总粉尘和呼吸性粉尘）及矿物纤维采样","methodology_cs":"Odběr vzorku prachu (celková a respirabilní frakce) a minerálních vláken","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek pyłu (frakcja wdychalna i respirabilna) oraz włókien mineralnych","reference":"SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC)","norm_bases":["SOP B_LBC 1, část 1-8","Nařízení vlády č. 361/2007 Sb., příloha 3","ČSN EN ISO 10882-1","ČSN EN 482","ČSN EN 689+AC"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Pobieranie próbek pyłu (frakcja wdychalna i respirabilna) oraz włókien mineralnych Pracovní ovzduší Odběr vzorku prachu (celková a respirabilní frakce) a minerálních vláken SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC) Powietrze na stanowiskach pracy Pobieranie probek pylu (frakcja wdychalna i respirabilna) oraz wlokien mineralnych Pracovni ovzdusi Odber vzorku prachu (celkova a respirabilni frakce) a mineralnich vlaken SOP B_LBC 1, cast 1-8 (Narizeni vlady c. 361/2007 Sb., priloha 3; CSN EN ISO 10882-1; CSN EN 482; CSN EN 689+AC)","search_en":"Workplace air Sampling of dust (total and respirable fraction) and mineral fibres SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC)","search_zh":"工作场所空气 粉尘（总粉尘和呼吸性粉尘）及矿物纤维采样 SOP B_LBC 1, část 1-8 (Nařízení vlády č. 361/2007 Sb., příloha 3; ČSN EN ISO 10882-1; ČSN EN 482; ČSN EN 689+AC)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}