{"lab":{"_id":"69ad52a4de79e566650fd45e","country":"CZ","accr_number":"1516","accr_body":"ČIA","address":"Hybešova 654, 664 42 Modřice","categories":["environment"],"city":"Modřice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":6,"name":"KOMPRAH, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1516_37_2026_CS.pdf","1516_37_2026_EN.pdf"],"scope_summary":"Pomiary hałasu w środowisku pracy i poza środowiskiem pracy, pomiary izolacyjności od dźwięków powietrznych i uderzeniowych oraz pomiary czasu pogłosu","search_text":"komprah, s.r.o. hybešova 654, 664 42 modřice 1516","status":"active","updated_at":"2026-03-08T14:52:13.236Z","valid_from":"","valid_until":"23-01-2031","website":"www.komprah.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.komprah.cz","map_coord":[49.128386,16.611624],"map_geo":"nominatim-street","certificate_date":"23.01.2026","certificate_no":"37/2026","certificate_replaces":"589/2024 z 08.11.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary hałasu w środowisku pracy i poza środowiskiem pracy, pomiary izolacyjności od dźwięków powietrznych i uderzeniowych oraz pomiary czasu pogłosu","en":"Noise measurement in the working and non-working environment, measurement of airborne and impact sound insulation and measurement of reverberation time","zh":"工作环境及非工作环境噪声测量、空气声和撞击声隔声测量以及混响时间测量","cs":"Měření hluku v pracovním i mimopracovním prostředí, měření vzduchové a kročejové neprůzvučnosti a měření doby dozvuku"}],"flexible_scope":true,"flexible_scope_url":"https://komprah.cz/","has_en":true,"has_zh":true,"lab_division":"laboratorium badawcze","lab_division_cs":"zkušební laboratoř","lab_division_en":"testing laboratory","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"MZ ČR","pl":"Ministerstwo Zdrowia Republiki Czeskiej","en":"Ministry of Health of the Czech Republic","zh":"捷克共和国卫生部","cs":"Ministerstvo zdravotnictví České republiky"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"dc39bf81dc55d990914d6781519b92b77b8a63b0c94ce3f29cf9489c3acae743","source_pdf_url":"https://www.cai.cz/OA/pdf/37_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"65e3aff3d6dd0a0d62dfc986","lab_id":"69ad52a4de79e566650fd45e","country":"CZ","accr_number":"1516","accr_body":"ČIA","row_label":"1","test_object":"Środowisko pracy","test_object_en":"Working environment","test_object_zh":"工作环境","test_object_cs":"Pracovní prostředí","methodology":"Pomiar poziomu ciśnienia akustycznego","methodology_en":"Measurement of sound pressure level","methodology_zh":"声压级测量","methodology_cs":"Měření hladiny akustického tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu ciśnienia akustycznego","reference":"Věstník MZ ČR, 2013, částka 4, část 4; ČSN EN ISO 9612","norm_bases":["Věstník MZ ČR, 2013, částka 4, část 4","ČSN EN ISO 9612"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pracy Pomiar poziomu ciśnienia akustycznego Pracovní prostředí Měření hladiny akustického tlaku Věstník MZ ČR, 2013, částka 4, část 4; ČSN EN ISO 9612 Srodowisko pracy Pomiar poziomu cisnienia akustycznego Pracovni prostredi Mereni hladiny akustickeho tlaku Vestnik MZ CR, 2013, castka 4, cast 4; CSN EN ISO 9612","search_en":"Working environment Measurement of sound pressure level Věstník MZ ČR, 2013, částka 4, část 4; ČSN EN ISO 9612","search_zh":"工作环境 声压级测量 Věstník MZ ČR, 2013, částka 4, část 4; ČSN EN ISO 9612","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d7f29219c5107a0be7c0b8b","lab_id":"69ad52a4de79e566650fd45e","country":"CZ","accr_number":"1516","accr_body":"ČIA","row_label":"2","test_object":"Środowisko poza miejscem pracy (przestrzeń zewnętrzna i wewnętrzna)","test_object_en":"Non-working environment (outdoor and indoor space)","test_object_zh":"非工作环境（室外和室内空间）","test_object_cs":"Mimopracovní prostředí (venkovní a vnitřní prostor)","methodology":"Pomiar poziomu ciśnienia akustycznego","methodology_en":"Measurement of sound pressure level","methodology_zh":"声压级测量","methodology_cs":"Měření hladiny akustického tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu ciśnienia akustycznego","reference":"Věstník MZ ČR, 2023, částka 14, část 3; ČSN ISO 1996-2","norm_bases":["Věstník MZ ČR, 2023, částka 14, část 3","ČSN ISO 1996-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko poza miejscem pracy (przestrzeń zewnętrzna i wewnętrzna) Pomiar poziomu ciśnienia akustycznego Mimopracovní prostředí (venkovní a vnitřní prostor) Měření hladiny akustického tlaku Věstník MZ ČR, 2023, částka 14, část 3; ČSN ISO 1996-2 Srodowisko poza miejscem pracy (przestrzen zewnetrzna i wewnetrzna) Pomiar poziomu cisnienia akustycznego Mimopracovni prostredi (venkovni a vnitrni prostor) Mereni hladiny akustickeho tlaku Vestnik MZ CR, 2023, castka 14, cast 3; CSN ISO 1996-2","search_en":"Non-working environment (outdoor and indoor space) Measurement of sound pressure level Věstník MZ ČR, 2023, částka 14, část 3; ČSN ISO 1996-2","search_zh":"非工作环境（室外和室内空间） 声压级测量 Věstník MZ ČR, 2023, částka 14, část 3; ČSN ISO 1996-2","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e3bf9dad04158dfa26c20ea0","lab_id":"69ad52a4de79e566650fd45e","country":"CZ","accr_number":"1516","accr_body":"ČIA","row_label":"3","test_object":"Przegrody budowlane","test_object_en":"Separating building elements","test_object_zh":"建筑隔断构件","test_object_cs":"Dělící prvky staveb","methodology":"Pomiar izolacyjności od dźwięków powietrznych","methodology_en":"Measurement of airborne sound insulation","methodology_zh":"空气声隔声测量","methodology_cs":"Měření vzduchové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności od dźwięków powietrznych","reference":"ČSN EN ISO 16283-1; ČSN EN ISO 717-1","norm_bases":["ČSN EN ISO 16283-1","ČSN EN ISO 717-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody budowlane Pomiar izolacyjności od dźwięków powietrznych Dělící prvky staveb Měření vzduchové neprůzvučnosti ČSN EN ISO 16283-1; ČSN EN ISO 717-1 Przegrody budowlane Pomiar izolacyjnosci od dzwiekow powietrznych Delici prvky staveb Mereni vzduchove nepruzvucnosti CSN EN ISO 16283-1; CSN EN ISO 717-1","search_en":"Separating building elements Measurement of airborne sound insulation ČSN EN ISO 16283-1; ČSN EN ISO 717-1","search_zh":"建筑隔断构件 空气声隔声测量 ČSN EN ISO 16283-1; ČSN EN ISO 717-1","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7599debf0f0eb74b674fa5fb","lab_id":"69ad52a4de79e566650fd45e","country":"CZ","accr_number":"1516","accr_body":"ČIA","row_label":"4","test_object":"Przegrody budowlane","test_object_en":"Separating building elements","test_object_zh":"建筑隔断构件","test_object_cs":"Dělící prvky staveb","methodology":"Pomiar izolacyjności od dźwięków uderzeniowych","methodology_en":"Measurement of impact sound insulation","methodology_zh":"撞击声隔声测量","methodology_cs":"Měření kročejové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności od dźwięków uderzeniowych","reference":"ČSN EN ISO 16283-2; ČSN EN ISO 717-2","norm_bases":["ČSN EN ISO 16283-2","ČSN EN ISO 717-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody budowlane Pomiar izolacyjności od dźwięków uderzeniowych Dělící prvky staveb Měření kročejové neprůzvučnosti ČSN EN ISO 16283-2; ČSN EN ISO 717-2 Przegrody budowlane Pomiar izolacyjnosci od dzwiekow uderzeniowych Delici prvky staveb Mereni krocejove nepruzvucnosti CSN EN ISO 16283-2; CSN EN ISO 717-2","search_en":"Separating building elements Measurement of impact sound insulation ČSN EN ISO 16283-2; ČSN EN ISO 717-2","search_zh":"建筑隔断构件 撞击声隔声测量 ČSN EN ISO 16283-2; ČSN EN ISO 717-2","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5e875d4e0ac746335b826660","lab_id":"69ad52a4de79e566650fd45e","country":"CZ","accr_number":"1516","accr_body":"ČIA","row_label":"5","test_object":"Pomieszczenia zwykłe","test_object_en":"Ordinary rooms","test_object_zh":"普通房间","test_object_cs":"Běžné prostory","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN EN ISO 3382-2","norm_bases":["ČSN EN ISO 3382-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia zwykłe Pomiar czasu pogłosu Běžné prostory Měření doby dozvuku ČSN EN ISO 3382-2 Pomieszczenia zwykle Pomiar czasu poglosu Bezne prostory Mereni doby dozvuku CSN EN ISO 3382-2","search_en":"Ordinary rooms Measurement of reverberation time ČSN EN ISO 3382-2","search_zh":"普通房间 混响时间测量 ČSN EN ISO 3382-2","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"782e7d8371f7496495dae771","lab_id":"69ad52a4de79e566650fd45e","country":"CZ","accr_number":"1516","accr_body":"ČIA","row_label":"6","test_object":"Pomieszczenia do wykonywania muzyki i mowy","test_object_en":"Performance spaces for music and speech","test_object_zh":"音乐和语言表演空间","test_object_cs":"Prostory pro přednes hudby, řeči","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN EN ISO 3382-1","norm_bases":["ČSN EN ISO 3382-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia do wykonywania muzyki i mowy Pomiar czasu pogłosu Prostory pro přednes hudby, řeči Měření doby dozvuku ČSN EN ISO 3382-1 Pomieszczenia do wykonywania muzyki i mowy Pomiar czasu poglosu Prostory pro prednes hudby, reci Mereni doby dozvuku CSN EN ISO 3382-1","search_en":"Performance spaces for music and speech Measurement of reverberation time ČSN EN ISO 3382-1","search_zh":"音乐和语言表演空间 混响时间测量 ČSN EN ISO 3382-1","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}