{"lab":{"_id":"69ad52a4de79e566650fd45c","accr_number":"1515","country":"CZ","accr_body":"ČIA","address":"Záluží 1, 436 70 Litvínov","categories":["petro","water"],"city":"Litvínov","imported_at":"2026-03-08T10:42:44.590Z","methods_count":62,"name":"ORLEN Unipetrol RPA s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1515_29_2026_CS.pdf","1515_29_2026_EN.pdf"],"scope_summary":"Analizy chemiczne i fizykochemiczne ropy naftowej i produktów naftowych wraz z pobieraniem ich próbek, analizy chemiczne wód podziemnych i ścieków, pobieranie próbek ścieków i wód powierzchniowych, w zakresie określonym w załączniku do świadectwa.","search_text":"orlen unipetrol rpa s.r.o. záluží 1, 436 70 litvínov 1515","status":"active","updated_at":"2026-03-08T14:52:13.236Z","valid_from":"","valid_until":"13-01-2031","website":"www.orlenunipetrolrpa.cz","map_coord":[50.561647,13.60206],"map_geo":"nominatim-street","certificate_date":"13.01.2026","certificate_no":"29/2026","certificate_replaces":"662/2024 z 05.12.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Analizy chemiczne i fizykochemiczne ropy naftowej i produktów naftowych wraz z pobieraniem ich próbek, analizy chemiczne wód podziemnych i ścieków, pobieranie próbek ścieków i wód powierzchniowych, w zakresie określonym w załączniku do świadectwa.","en":"Chemical and physicochemical analyses of petroleum and petroleum products including sampling, chemical analyses of ground water and waste water, sampling of waste water and surface water to the extent as specified in the appendix to this Certificate.","zh":"原油和石油产品的化学及物理化学分析（包括采样），地下水和废水化学分析，废水和地表水采样，范围见本证书附件。","cs":"Chemické a fyzikálně-chemické analýzy ropy a ropných produktů včetně jejich odběrů, chemické analýzy podzemních a odpadních vod, odběr vzorků odpadních a povrchových vod, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Rafinerii","lab_division_cs":"Laboratoř Rafinérie","lab_division_en":"Refinery Laboratory","lab_division_zh":"炼油厂实验室","lab_locations":[{"code":null,"name":"ORLEN Unipetrol RPA s.r.o.","street":"Záluží 1","postal_code":"436 70","city":"Litvínov","is_hq":true,"address":"Záluží 1, 436 70 Litvínov","site":"43670|záluží1"},{"code":null,"name":"Laboratoria Litvínov","street":"Záluží 1","postal_code":"436 70","city":"Litvínov","is_hq":false,"address":"Záluží 1, 436 70 Litvínov","site":"43670|záluží1"},{"code":null,"name":"Laboratoria Kralupy","street":"Wichterleho 809","postal_code":"278 01","city":"Kralupy nad Vltavou","is_hq":false,"address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","site":"27801|wichterleho809"}],"lab_locations_en":[{"code":null,"name":"ORLEN Unipetrol RPA s.r.o.","street":"Záluží 1","postal_code":"436 70","city":"Litvínov","is_hq":true,"address":"Záluží 1, 436 70 Litvínov","site":"43670|záluží1"},{"code":null,"name":"Litvínov Laboratories","street":"Záluží 1","postal_code":"436 70","city":"Litvínov","is_hq":false,"address":"Záluží 1, 436 70 Litvínov","site":"43670|záluží1"},{"code":null,"name":"Kralupy Laboratories","street":"Wichterleho 809","postal_code":"278 01","city":"Kralupy nad Vltavou","is_hq":false,"address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","site":"27801|wichterleho809"}],"lab_locations_zh":[{"code":null,"name":"ORLEN Unipetrol RPA s.r.o.","street":"Záluží 1","postal_code":"436 70","city":"Litvínov","is_hq":true,"address":"Záluží 1, 436 70 Litvínov","site":"43670|záluží1"},{"code":null,"name":"利特维诺夫实验室","street":"Záluží 1","postal_code":"436 70","city":"Litvínov","is_hq":false,"address":"Záluží 1, 436 70 Litvínov","site":"43670|záluží1"},{"code":null,"name":"克拉卢比实验室","street":"Wichterleho 809","postal_code":"278 01","city":"Kralupy nad Vltavou","is_hq":false,"address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","site":"27801|wichterleho809"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"DCN","pl":"Pochodna liczba cetanowa","en":"Derived Cetane Number","zh":"导出十六烷值","cs":"Derivované cetanové číslo"},{"abbr":"DVPE","pl":"Równoważnik prężności par suchych (DVPE)","en":"Dry Vapour Pressure Equivalent","zh":"干蒸气压当量","cs":"Dry vapour pressure equivalent"},{"abbr":"ETBE","pl":"Eter etylowo-tert-butylowy","en":"Ethyl-tert-butyl ether","zh":"乙基叔丁基醚","cs":"Ethyltercbutylether"},{"abbr":"FID","pl":"Detektor płomieniowo-jonizacyjny","en":"Flame Ionization Detector","zh":"火焰离子化检测器","cs":"Plamenově ionizační detektor"},{"abbr":"FLD","pl":"Detektor fluorescencyjny","en":"Fluorescence Detector","zh":"荧光检测器","cs":"Fluorescenční detektor"},{"abbr":"GC","pl":"Chromatografia gazowa","en":"Gas Chromatography","zh":"气相色谱","cs":"Plynová chromatografie"},{"abbr":"HPLC","pl":"Wysokosprawna chromatografia cieczowa","en":"High-Performance Liquid Chromatography","zh":"高效液相色谱","cs":"Vysokoúčinná kapalinová chromatografie"},{"abbr":"IČ","pl":"Spektrometria w podczerwieni","en":"Infrared Spectroscopy","zh":"红外光谱","cs":"Infračervená spektrometrie"},{"abbr":"Kapalné uhlovodíky","pl":"Paliwa silnikowe, oleje opałowe, nafta lotnicza, LPG","en":"Motor fuels, heating oils, aviation kerosene, LPG","zh":"发动机燃料、燃料油、航空煤油、液化石油气","cs":"Motorová paliva, topné oleje, letecký petrolej, LPG"},{"abbr":"LPG","pl":"Gaz płynny (skroplone gazy ropopochodne)","en":"Liquefied petroleum gases","zh":"液化石油气","cs":"Zkapalněné ropné plyny"},{"abbr":"MS","pl":"Detektor mas","en":"Mass detector","zh":"质谱检测器","cs":"Hmotnostní detektor"},{"abbr":"MTBE","pl":"Eter metylowo-tert-butylowy","en":"Methyl-t-butyl ether","zh":"甲基叔丁基醚","cs":"Methyltercbutylether"},{"abbr":"RTG","pl":"Rentgenowska spektrometria fluorescencyjna","en":"X-ray fluorescence spectrometry","zh":"X射线荧光光谱","cs":"Rentgenová fluorescenční spektrometrie"},{"abbr":"TCD","pl":"Detektor cieplno-przewodnościowy","en":"Thermal Conductivity Detector","zh":"热导检测器","cs":"Tepelně vodivostní detektor"},{"abbr":"UV","pl":"Fluorescencja w nadfiolecie","en":"Ultraviolet Fluorescence","zh":"紫外荧光","cs":"Ultrafialová fluorescence"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The Laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立开展采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"99e32bb0286ad030533168790138524c2edabc8b30b494af69ddffb28ed2a0b5","source_pdf_url":"https://www.cai.cz/OA/pdf/29_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/29_2026_EN.pdf"},"methods":[{"_id":"eb1b6d95f076e13d6a34703d","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"1","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie krzywej destylacji pod ciśnieniem atmosferycznym","methodology_en":"Determination of distillation characteristics at atmospheric pressure","methodology_zh":"常压蒸馏特性测定","methodology_cs":"Stanovení destilační křivky při atmosférickém tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie krzywej destylacji pod ciśnieniem atmosferycznym","reference":"LP-0013L (ČSN EN ISO 3405; ASTM D86)","norm_bases":["LP-0013L","ČSN EN ISO 3405","ASTM D86"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie krzywej destylacji pod ciśnieniem atmosferycznym Kapalné uhlovodíky Stanovení destilační křivky při atmosférickém tlaku LP-0013L (ČSN EN ISO 3405; ASTM D86) Weglowodory ciekle Oznaczanie krzywej destylacji pod cisnieniem atmosferycznym Kapalne uhlovodiky Stanoveni destilacni krivky pri atmosferickem tlaku LP-0013L (CSN EN ISO 3405; ASTM D86)","search_en":"Liquid hydrocarbons Determination of distillation characteristics at atmospheric pressure LP-0013L (ČSN EN ISO 3405; ASTM D86)","search_zh":"液态烃 常压蒸馏特性测定 LP-0013L (ČSN EN ISO 3405; ASTM D86)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad914bb23a79d9521da8e916","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"2","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie lepkości kinematycznej wiskozymetrem Stabingera","methodology_en":"Determination of kinematic viscosity by Stabinger viscometer","methodology_zh":"Stabinger粘度计测定运动粘度","methodology_cs":"Stanovení kinematické viskozity na přístroji Stabinger","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lepkości kinematycznej wiskozymetrem Stabingera","reference":"LP 0040L (ASTM D7042)","norm_bases":["LP 0040L","ASTM D7042"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie lepkości kinematycznej wiskozymetrem Stabingera Kapalné uhlovodíky Stanovení kinematické viskozity na přístroji Stabinger LP 0040L (ASTM D7042) Weglowodory ciekle Oznaczanie lepkosci kinematycznej wiskozymetrem Stabingera Kapalne uhlovodiky Stanoveni kinematicke viskozity na pristroji Stabinger LP 0040L (ASTM D7042)","search_en":"Liquid hydrocarbons Determination of kinematic viscosity by Stabinger viscometer LP 0040L (ASTM D7042)","search_zh":"液态烃 Stabinger粘度计测定运动粘度 LP 0040L (ASTM D7042)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad058893423c150d67cb4b87","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"3","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie prężności par nasyconych (DVPE)","methodology_en":"Determination of saturated vapour pressure and calculation of (DVPE)","methodology_zh":"饱和蒸气压测定（DVPE）","methodology_cs":"Stanovení tlaku nasycených par (DVPE)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prężności par nasyconych (DVPE)","reference":"LP-0021L (ČSN EN 13016-1)","norm_bases":["LP-0021L","ČSN EN 13016-1"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie prężności par nasyconych (DVPE) Kapalné uhlovodíky Stanovení tlaku nasycených par (DVPE) LP-0021L (ČSN EN 13016-1) Weglowodory ciekle Oznaczanie preznosci par nasyconych (DVPE) Kapalne uhlovodiky Stanoveni tlaku nasycenych par (DVPE) LP-0021L (CSN EN 13016-1)","search_en":"Liquid hydrocarbons Determination of saturated vapour pressure and calculation of (DVPE) LP-0021L (ČSN EN 13016-1)","search_zh":"液态烃 饱和蒸气压测定（DVPE） LP-0021L (ČSN EN 13016-1)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cbf20f09ab37a1877eed9d77","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"4","test_object":"Paliwa silnikowe i oleje opałowe","test_object_en":"Motor fuels and heating oils","test_object_zh":"发动机燃料和燃料油","test_object_cs":"Motorová paliva a topné oleje","methodology":"Oznaczanie temperatury zapłonu w tyglu zamkniętym – metoda Pensky’ego-Martensa","methodology_en":"Determination of flash point – Pensky-Martens closed cup","methodology_zh":"闭口杯闪点测定 – 宾斯基-马丁法","methodology_cs":"Stanovení bodu vzplanutí v uzavřeném kelímku – Pensky – Martens","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury zapłonu w tyglu zamkniętym – metoda Pensky’ego-Martensa","reference":"LP-0023L (ČSN EN ISO 2719)","norm_bases":["LP-0023L","ČSN EN ISO 2719"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe i oleje opałowe Oznaczanie temperatury zapłonu w tyglu zamkniętym – metoda Pensky’ego-Martensa Motorová paliva a topné oleje Stanovení bodu vzplanutí v uzavřeném kelímku – Pensky – Martens LP-0023L (ČSN EN ISO 2719) Paliwa silnikowe i oleje opalowe Oznaczanie temperatury zaplonu w tyglu zamknietym – metoda Pensky’ego-Martensa Motorova paliva a topne oleje Stanoveni bodu vzplanuti v uzavrenem kelimku – Pensky – Martens LP-0023L (CSN EN ISO 2719)","search_en":"Motor fuels and heating oils Determination of flash point – Pensky-Martens closed cup LP-0023L (ČSN EN ISO 2719)","search_zh":"发动机燃料和燃料油 闭口杯闪点测定 – 宾斯基-马丁法 LP-0023L (ČSN EN ISO 2719)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"35680983b9903f07687ee687","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"5","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie estrów metylowych kwasów tłuszczowych (FAME) metodą IR","methodology_en":"Determination of fatty acid methyl esters (FAME) by IR method","methodology_zh":"红外法测定脂肪酸甲酯（FAME）","methodology_cs":"Stanovení methylesterů mastných kyselin (FAME) metodou IČ","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie estrów metylowych kwasów tłuszczowych (FAME) metodą IR","reference":"LP-0244L (ČSN EN 14078; ASTM D7371)","norm_bases":["LP-0244L","ČSN EN 14078","ASTM D7371"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie estrów metylowych kwasów tłuszczowych (FAME) metodą IR Motorová paliva Stanovení methylesterů mastných kyselin (FAME) metodou IČ LP-0244L (ČSN EN 14078; ASTM D7371) Paliwa silnikowe Oznaczanie estrow metylowych kwasow tluszczowych (FAME) metoda IR Motorova paliva Stanoveni methylesteru mastnych kyselin (FAME) metodou IC LP-0244L (CSN EN 14078; ASTM D7371)","search_en":"Motor fuels Determination of fatty acid methyl esters (FAME) by IR method LP-0244L (ČSN EN 14078; ASTM D7371)","search_zh":"发动机燃料 红外法测定脂肪酸甲酯（FAME） LP-0244L (ČSN EN 14078; ASTM D7371)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"37c8932712a1fa469a9fc16a","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"6","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości grup węglowodorów, benzenu i związków tlenowych metodą wielowymiarowej GC/FID","methodology_en":"Determination of the content of hydrocarbon groups, benzene and oxygenates by multidimensional GC/FID method","methodology_zh":"多维GC/FID法测定烃族组成、苯和含氧化合物含量","methodology_cs":"Stanovení obsahu skupin uhlovodíků, benzenu a kyslíkatých látek metodou multidimenzionální GC/FID","parameters":[{"name":"Benzen","range":""},{"name":"Metanol","range":""},{"name":"Etanol","range":""},{"name":"Alkohol izopropylowy","range":""},{"name":"Alkohol izobutylowy","range":""},{"name":"Alkohol tert-butylowy","range":""},{"name":"Eter metylowo-tert-butylowy (MTBE)","range":""},{"name":"Eter etylowo-tert-butylowy (ETBE)","range":""},{"name":"Węglowodory aromatyczne","range":""},{"name":"Olefiny","range":""},{"name":"Całkowita zawartość tlenu","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"Methanol","range":""},{"name":"Ethanol","range":""},{"name":"Isopropyl alcohol","range":""},{"name":"Isobutyl alcohol","range":""},{"name":"tert-Butyl alcohol","range":""},{"name":"Methyl tert-butyl ether (MTBE)","range":""},{"name":"Ethyl tert-butyl ether (ETBE)","range":""},{"name":"Aromatics","range":""},{"name":"Olefins","range":""},{"name":"Total oxygen content","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲醇","range":""},{"name":"乙醇","range":""},{"name":"异丙醇","range":""},{"name":"异丁醇","range":""},{"name":"叔丁醇","range":""},{"name":"甲基叔丁基醚（MTBE）","range":""},{"name":"乙基叔丁基醚（ETBE）","range":""},{"name":"芳烃","range":""},{"name":"烯烃","range":""},{"name":"总氧含量","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"methanol","range":""},{"name":"ethanol","range":""},{"name":"isopropylalkohol","range":""},{"name":"isobutylalkohol","range":""},{"name":"tercbutylalkohol","range":""},{"name":"methyltercbutylether (MTBE)","range":""},{"name":"ethyltercbutylether (ETBE)","range":""},{"name":"aromáty","range":""},{"name":"olefíny","range":""},{"name":"celkový obsah kyslíku","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości grup węglowodorów, benzenu i związków tlenowych metodą wielowymiarowej GC/FID\nZakres:\nBenzen\nMetanol\nEtanol\nAlkohol izopropylowy\nAlkohol izobutylowy\nAlkohol tert-butylowy\nEter metylowo-tert-butylowy (MTBE)\nEter etylowo-tert-butylowy (ETBE)\nWęglowodory aromatyczne\nOlefiny\nCałkowita zawartość tlenu","reference":"LP-0063RL (ČSN EN ISO 22854)","norm_bases":["LP-0063RL","ČSN EN ISO 22854"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości grup węglowodorów, benzenu i związków tlenowych metodą wielowymiarowej GC/FID Benzen  Metanol  Etanol  Alkohol izopropylowy  Alkohol izobutylowy  Alkohol tert-butylowy  Eter metylowo-tert-butylowy (MTBE)  Eter etylowo-tert-butylowy (ETBE)  Węglowodory aromatyczne  Olefiny  Całkowita zawartość tlenu  Kapalné uhlovodíky Stanovení obsahu skupin uhlovodíků, benzenu a kyslíkatých látek metodou multidimenzionální GC/FID benzen  methanol  ethanol  isopropylalkohol  isobutylalkohol  tercbutylalkohol  methyltercbutylether (MTBE)  ethyltercbutylether (ETBE)  aromáty  olefíny  celkový obsah kyslíku  LP-0063RL (ČSN EN ISO 22854) Weglowodory ciekle Oznaczanie zawartosci grup weglowodorow, benzenu i zwiazkow tlenowych metoda wielowymiarowej GC/FID Benzen  Metanol  Etanol  Alkohol izopropylowy  Alkohol izobutylowy  Alkohol tert-butylowy  Eter metylowo-tert-butylowy (MTBE)  Eter etylowo-tert-butylowy (ETBE)  Weglowodory aromatyczne  Olefiny  Calkowita zawartosc tlenu  Kapalne uhlovodiky Stanoveni obsahu skupin uhlovodiku, benzenu a kyslikatych latek metodou multidimenzionalni GC/FID benzen  methanol  ethanol  isopropylalkohol  isobutylalkohol  tercbutylalkohol  methyltercbutylether (MTBE)  ethyltercbutylether (ETBE)  aromaty  olefiny  celkovy obsah kysliku  LP-0063RL (CSN EN ISO 22854)","search_en":"Liquid hydrocarbons Determination of the content of hydrocarbon groups, benzene and oxygenates by multidimensional GC/FID method Benzene  Methanol  Ethanol  Isopropyl alcohol  Isobutyl alcohol  tert-Butyl alcohol  Methyl tert-butyl ether (MTBE)  Ethyl tert-butyl ether (ETBE)  Aromatics  Olefins  Total oxygen content  LP-0063RL (ČSN EN ISO 22854)","search_zh":"液态烃 多维GC/FID法测定烃族组成、苯和含氧化合物含量 苯  甲醇  乙醇  异丙醇  异丁醇  叔丁醇  甲基叔丁基醚（MTBE）  乙基叔丁基醚（ETBE）  芳烃  烯烃  总氧含量  LP-0063RL (ČSN EN ISO 22854)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0dabfdf41838abd8ef58c5a5","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"7","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości siarki metodą fluorescencji w nadfiolecie (UV)","methodology_en":"Determination of sulphur content by UV fluorescence method","methodology_zh":"紫外荧光法测定硫含量","methodology_cs":"Stanovení obsahu síry metodou UV fluorescence","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości siarki metodą fluorescencji w nadfiolecie (UV)","reference":"LP-0025L (ČSN EN ISO 20846; ASTM D5453)","norm_bases":["LP-0025L","ČSN EN ISO 20846","ASTM D5453"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości siarki metodą fluorescencji w nadfiolecie (UV) Kapalné uhlovodíky Stanovení obsahu síry metodou UV fluorescence LP-0025L (ČSN EN ISO 20846; ASTM D5453) Weglowodory ciekle Oznaczanie zawartosci siarki metoda fluorescencji w nadfiolecie (UV) Kapalne uhlovodiky Stanoveni obsahu siry metodou UV fluorescence LP-0025L (CSN EN ISO 20846; ASTM D5453)","search_en":"Liquid hydrocarbons Determination of sulphur content by UV fluorescence method LP-0025L (ČSN EN ISO 20846; ASTM D5453)","search_zh":"液态烃 紫外荧光法测定硫含量 LP-0025L (ČSN EN ISO 20846; ASTM D5453)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"492b667e30c533c404e379a2","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"8","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym","methodology_en":"Determination of cold filter plugging point (CFPP) using an automatic analyzer","methodology_zh":"自动分析仪测定冷滤点（CFPP）","methodology_cs":"Stanovení filtrovatelnosti (CFPP) automatickým analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym","reference":"LP-0012L (ČSN EN 116; ASTM D6371)","norm_bases":["LP-0012L","ČSN EN 116","ASTM D6371"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym Motorová paliva Stanovení filtrovatelnosti (CFPP) automatickým analyzátorem LP-0012L (ČSN EN 116; ASTM D6371) Paliwa silnikowe Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym Motorova paliva Stanoveni filtrovatelnosti (CFPP) automatickym analyzatorem LP-0012L (CSN EN 116; ASTM D6371)","search_en":"Motor fuels Determination of cold filter plugging point (CFPP) using an automatic analyzer LP-0012L (ČSN EN 116; ASTM D6371)","search_zh":"发动机燃料 自动分析仪测定冷滤点（CFPP） LP-0012L (ČSN EN 116; ASTM D6371)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77c156deab53399442bd0b6b","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"9","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie liczby oktanowej metodą badawczą","methodology_en":"Determination of knock characteristics by research method","methodology_zh":"研究法辛烷值测定","methodology_cs":"Stanovení oktanového čísla výzkumnou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby oktanowej metodą badawczą","reference":"LP-0045L (ČSN EN ISO 5164; ASTM D2699)","norm_bases":["LP-0045L","ČSN EN ISO 5164","ASTM D2699"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie liczby oktanowej metodą badawczą Motorová paliva Stanovení oktanového čísla výzkumnou metodou LP-0045L (ČSN EN ISO 5164; ASTM D2699) Paliwa silnikowe Oznaczanie liczby oktanowej metoda badawcza Motorova paliva Stanoveni oktanoveho cisla vyzkumnou metodou LP-0045L (CSN EN ISO 5164; ASTM D2699)","search_en":"Motor fuels Determination of knock characteristics by research method LP-0045L (ČSN EN ISO 5164; ASTM D2699)","search_zh":"发动机燃料 研究法辛烷值测定 LP-0045L (ČSN EN ISO 5164; ASTM D2699)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"811e882d4b822a08e40de15e","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"10","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie liczby oktanowej metodą motorową","methodology_en":"Determination of knock characteristics by engine method","methodology_zh":"马达法辛烷值测定","methodology_cs":"Stanovení oktanového čísla motorovou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby oktanowej metodą motorową","reference":"LP-0046L (ČSN EN ISO 5163; ASTM D2700)","norm_bases":["LP-0046L","ČSN EN ISO 5163","ASTM D2700"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie liczby oktanowej metodą motorową Motorová paliva Stanovení oktanového čísla motorovou metodou LP-0046L (ČSN EN ISO 5163; ASTM D2700) Paliwa silnikowe Oznaczanie liczby oktanowej metoda motorowa Motorova paliva Stanoveni oktanoveho cisla motorovou metodou LP-0046L (CSN EN ISO 5163; ASTM D2700)","search_en":"Motor fuels Determination of knock characteristics by engine method LP-0046L (ČSN EN ISO 5163; ASTM D2700)","search_zh":"发动机燃料 马达法辛烷值测定 LP-0046L (ČSN EN ISO 5163; ASTM D2700)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af1d36517c88e9abbfc7c495","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"11","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie chlorków metodą elektrometryczną","methodology_en":"Determination of chlorides by electrometric method","methodology_zh":"电位法测定氯化物","methodology_cs":"Stanovení chloridů elektrometrickou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą elektrometryczną","reference":"LP-0014L (ASTM D3230)","norm_bases":["LP-0014L","ASTM D3230"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie chlorków metodą elektrometryczną Kapalné uhlovodíky Stanovení chloridů elektrometrickou metodou LP-0014L (ASTM D3230) Weglowodory ciekle Oznaczanie chlorkow metoda elektrometryczna Kapalne uhlovodiky Stanoveni chloridu elektrometrickou metodou LP-0014L (ASTM D3230)","search_en":"Liquid hydrocarbons Determination of chlorides by electrometric method LP-0014L (ASTM D3230)","search_zh":"液态烃 电位法测定氯化物 LP-0014L (ASTM D3230)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd1eb6c8c17b65a26f742bb1","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"12","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości siarki metodą fluorescencji rentgenowskiej","methodology_en":"Determination of sulphur content by X-ray fluorescence method","methodology_zh":"X射线荧光法测定硫含量","methodology_cs":"Stanovení obsahu síry metodou RTG fluorescence","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości siarki metodą fluorescencji rentgenowskiej","reference":"LP-0033L (ČSN EN ISO 8754; ASTM D4294)","norm_bases":["LP-0033L","ČSN EN ISO 8754","ASTM D4294"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości siarki metodą fluorescencji rentgenowskiej Kapalné uhlovodíky Stanovení obsahu síry metodou RTG fluorescence LP-0033L (ČSN EN ISO 8754; ASTM D4294) Weglowodory ciekle Oznaczanie zawartosci siarki metoda fluorescencji rentgenowskiej Kapalne uhlovodiky Stanoveni obsahu siry metodou RTG fluorescence LP-0033L (CSN EN ISO 8754; ASTM D4294)","search_en":"Liquid hydrocarbons Determination of sulphur content by X-ray fluorescence method LP-0033L (ČSN EN ISO 8754; ASTM D4294)","search_zh":"液态烃 X射线荧光法测定硫含量 LP-0033L (ČSN EN ISO 8754; ASTM D4294)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e1eed1b23b7ea554028eb29","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"13","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości wody metodą miareczkową Karla Fischera","methodology_en":"Determination of water content by titration – Karl Fischer method","methodology_zh":"卡尔·费休滴定法测定水含量","methodology_cs":"Stanovení obsahu vody titrační metodou K. Fischera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wody metodą miareczkową Karla Fischera","reference":"LP-0037L (ČSN ISO 760)","norm_bases":["LP-0037L","ČSN ISO 760"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości wody metodą miareczkową Karla Fischera Kapalné uhlovodíky Stanovení obsahu vody titrační metodou K. Fischera LP-0037L (ČSN ISO 760) Weglowodory ciekle Oznaczanie zawartosci wody metoda miareczkowa Karla Fischera Kapalne uhlovodiky Stanoveni obsahu vody titracni metodou K. Fischera LP-0037L (CSN ISO 760)","search_en":"Liquid hydrocarbons Determination of water content by titration – Karl Fischer method LP-0037L (ČSN ISO 760)","search_zh":"液态烃 卡尔·费休滴定法测定水含量 LP-0037L (ČSN ISO 760)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"865283d83f46b4c32b441b2f","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"14","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie gęstości densymetrem (gęstościomierzem oscylacyjnym)","methodology_en":"Determination of density by densitometer","methodology_zh":"密度计测定密度","methodology_cs":"Stanovení hustoty denzitometrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości densymetrem (gęstościomierzem oscylacyjnym)","reference":"LP-0008L, metoda A (ČSN EN ISO 12185; ASTM D4052)","norm_bases":["LP-0008L, metoda A","ČSN EN ISO 12185","ASTM D4052"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie gęstości densymetrem (gęstościomierzem oscylacyjnym) Kapalné uhlovodíky Stanovení hustoty denzitometrem LP-0008L, metoda A (ČSN EN ISO 12185; ASTM D4052) Weglowodory ciekle Oznaczanie gestosci densymetrem (gestosciomierzem oscylacyjnym) Kapalne uhlovodiky Stanoveni hustoty denzitometrem LP-0008L, metoda A (CSN EN ISO 12185; ASTM D4052)","search_en":"Liquid hydrocarbons Determination of density by densitometer LP-0008L, metoda A (ČSN EN ISO 12185; ASTM D4052)","search_zh":"液态烃 密度计测定密度 LP-0008L, metoda A (ČSN EN ISO 12185; ASTM D4052)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f377392d83116758f52303c","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"15","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie gęstości areometrem szklanym","methodology_en":"Determination of density by glass densitometer","methodology_zh":"玻璃比重计测定密度","methodology_cs":"Stanovení hustoty skleněným hustoměrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości areometrem szklanym","reference":"LP-0008/L, metoda B (ČSN EN ISO 3675)","norm_bases":["LP-0008/L, metoda B","ČSN EN ISO 3675"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie gęstości areometrem szklanym Kapalné uhlovodíky Stanovení hustoty skleněným hustoměrem LP-0008/L, metoda B (ČSN EN ISO 3675) Weglowodory ciekle Oznaczanie gestosci areometrem szklanym Kapalne uhlovodiky Stanoveni hustoty sklenenym hustomerem LP-0008/L, metoda B (CSN EN ISO 3675)","search_en":"Liquid hydrocarbons Determination of density by glass densitometer LP-0008/L, metoda B (ČSN EN ISO 3675)","search_zh":"液态烃 玻璃比重计测定密度 LP-0008/L, metoda B (ČSN EN ISO 3675)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b90e35a6ea322ee5aab69520","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"16","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zanieczyszczeń mechanicznych metodą filtracji","methodology_en":"Determination of mechanical impurities by filtration","methodology_zh":"过滤法测定机械杂质","methodology_cs":"Stanovení mechanických nečistot filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zanieczyszczeń mechanicznych metodą filtracji","reference":"LP-0055L (ČSN 65 6080)","norm_bases":["LP-0055L","ČSN 65 6080"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zanieczyszczeń mechanicznych metodą filtracji Kapalné uhlovodíky Stanovení mechanických nečistot filtrací LP-0055L (ČSN 65 6080) Weglowodory ciekle Oznaczanie zanieczyszczen mechanicznych metoda filtracji Kapalne uhlovodiky Stanoveni mechanickych necistot filtraci LP-0055L (CSN 65 6080)","search_en":"Liquid hydrocarbons Determination of mechanical impurities by filtration LP-0055L (ČSN 65 6080)","search_zh":"液态烃 过滤法测定机械杂质 LP-0055L (ČSN 65 6080)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7385415609ce436842e5eba8","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"17","test_object":"Gazy rafineryjne","test_object_en":"Refinery gas","test_object_zh":"炼厂气","test_object_cs":"Rafinérské plyny","methodology":"Oznaczanie składu gazów rafineryjnych metodą GC/FID/TCD","methodology_en":"Determination of refinery gas composition by GC/FID, TCD method","methodology_zh":"GC/FID/TCD法测定炼厂气组成","methodology_cs":"Stanovení složení rafinérských plynů metodou GC/FID/TCD","parameters":[{"name":"Wodór","range":""},{"name":"Azot","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"Metan","range":""},{"name":"Etan","range":""},{"name":"Etylen","range":""},{"name":"Propan","range":""},{"name":"Propylen","range":""},{"name":"Izobutan","range":""},{"name":"n-Butan","range":""},{"name":"trans-Buten","range":""},{"name":"n-Buten","range":""},{"name":"Izobuten","range":""},{"name":"cis-Buten","range":""},{"name":"Izopentan","range":""},{"name":"n-Pentan","range":""},{"name":"Węglowodory C6 i wyższe","range":""},{"name":"Suma węglowodorów","range":""},{"name":"Zawartość wody","range":""}],"parameters_en":[{"name":"Hydrogen","range":""},{"name":"Nitrogen","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"Methane","range":""},{"name":"Ethane","range":""},{"name":"Ethylene","range":""},{"name":"Propane","range":""},{"name":"Propylene","range":""},{"name":"Isobutane","range":""},{"name":"n-Butane","range":""},{"name":"t-Butene","range":""},{"name":"n-Butene","range":""},{"name":"i-Butene","range":""},{"name":"c-Butene","range":""},{"name":"Isopentane","range":""},{"name":"n-Pentane","range":""},{"name":"C6-hydrocarbons+higher","range":""},{"name":"Sum of hydrocarbons","range":""},{"name":"Water content","range":""}],"parameters_zh":[{"name":"氢","range":""},{"name":"氮","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"甲烷","range":""},{"name":"乙烷","range":""},{"name":"乙烯","range":""},{"name":"丙烷","range":""},{"name":"丙烯","range":""},{"name":"异丁烷","range":""},{"name":"正丁烷","range":""},{"name":"反丁烯","range":""},{"name":"正丁烯","range":""},{"name":"异丁烯","range":""},{"name":"顺丁烯","range":""},{"name":"异戊烷","range":""},{"name":"正戊烷","range":""},{"name":"C6及以上烃","range":""},{"name":"烃总量","range":""},{"name":"水含量","range":""}],"parameters_cs":[{"name":"vodík","range":""},{"name":"dusík","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"metan","range":""},{"name":"etan","range":""},{"name":"etylen","range":""},{"name":"propan","range":""},{"name":"propylen","range":""},{"name":"isobutan","range":""},{"name":"n-butan","range":""},{"name":"t-buten","range":""},{"name":"n-buten","range":""},{"name":"i-buten","range":""},{"name":"c-buten","range":""},{"name":"isopentan","range":""},{"name":"n-pentan","range":""},{"name":"C6-uhlovodíky+vyšší","range":""},{"name":"suma uhlovodíků","range":""},{"name":"obsah vody","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie składu gazów rafineryjnych metodą GC/FID/TCD\nZakres:\nWodór\nAzot\nCO\nCO2\nMetan\nEtan\nEtylen\nPropan\nPropylen\nIzobutan\nn-Butan\ntrans-Buten\nn-Buten\nIzobuten\ncis-Buten\nIzopentan\nn-Pentan\nWęglowodory C6 i wyższe\nSuma węglowodorów\nZawartość wody","reference":"LP-0026L (ČSN EN ISO 6974-6; ISO 7941)","norm_bases":["LP-0026L","ČSN EN ISO 6974-6","ISO 7941"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gazy rafineryjne Oznaczanie składu gazów rafineryjnych metodą GC/FID/TCD Wodór  Azot  CO  CO2  Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Węglowodory C6 i wyższe  Suma węglowodorów  Zawartość wody  Rafinérské plyny Stanovení složení rafinérských plynů metodou GC/FID/TCD vodík  dusík  CO  CO2  metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  C6-uhlovodíky+vyšší  suma uhlovodíků  obsah vody  LP-0026L (ČSN EN ISO 6974-6; ISO 7941) Gazy rafineryjne Oznaczanie skladu gazow rafineryjnych metoda GC/FID/TCD Wodor  Azot  CO  CO2  Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Weglowodory C6 i wyzsze  Suma weglowodorow  Zawartosc wody  Rafinerske plyny Stanoveni slozeni rafinerskych plynu metodou GC/FID/TCD vodik  dusik  CO  CO2  metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  C6-uhlovodiky+vyssi  suma uhlovodiku  obsah vody  LP-0026L (CSN EN ISO 6974-6; ISO 7941)","search_en":"Refinery gas Determination of refinery gas composition by GC/FID, TCD method Hydrogen  Nitrogen  CO  CO2  Methane  Ethane  Ethylene  Propane  Propylene  Isobutane  n-Butane  t-Butene  n-Butene  i-Butene  c-Butene  Isopentane  n-Pentane  C6-hydrocarbons+higher  Sum of hydrocarbons  Water content  LP-0026L (ČSN EN ISO 6974-6; ISO 7941)","search_zh":"炼厂气 GC/FID/TCD法测定炼厂气组成 氢  氮  CO  CO2  甲烷  乙烷  乙烯  丙烷  丙烯  异丁烷  正丁烷  反丁烯  正丁烯  异丁烯  顺丁烯  异戊烷  正戊烷  C6及以上烃  烃总量  水含量  LP-0026L (ČSN EN ISO 6974-6; ISO 7941)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c4f8e3ee46e232739450465","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"18","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości wodoru i węgla analizatorem elementarnym","methodology_en":"Determination of hydrogen and carbon content by elemental analyzer","methodology_zh":"元素分析仪测定氢和碳含量","methodology_cs":"Stanovení obsahu vodíku a uhlíku elementárním analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wodoru i węgla analizatorem elementarnym","reference":"LP-0198AL (ASTM D5291)","norm_bases":["LP-0198AL","ASTM D5291"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości wodoru i węgla analizatorem elementarnym Kapalné uhlovodíky Stanovení obsahu vodíku a uhlíku elementárním analyzátorem LP-0198AL (ASTM D5291) Weglowodory ciekle Oznaczanie zawartosci wodoru i wegla analizatorem elementarnym Kapalne uhlovodiky Stanoveni obsahu vodiku a uhliku elementarnim analyzatorem LP-0198AL (ASTM D5291)","search_en":"Liquid hydrocarbons Determination of hydrogen and carbon content by elemental analyzer LP-0198AL (ASTM D5291)","search_zh":"液态烃 元素分析仪测定氢和碳含量 LP-0198AL (ASTM D5291)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"57ec56f154f0ec55fef8e43d","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"19","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości wody metodą kulometryczną Karla Fischera","methodology_en":"Determination of water – Coulometric Karl Fischer titration method","methodology_zh":"库仑卡尔·费休法测定水含量","methodology_cs":"Stanovení obsahu vody coulometrickou metodou K. Fischera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wody metodą kulometryczną Karla Fischera","reference":"LP-0031L (ČSN EN ISO 12937)","norm_bases":["LP-0031L","ČSN EN ISO 12937"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości wody metodą kulometryczną Karla Fischera Kapalné uhlovodíky Stanovení obsahu vody coulometrickou metodou K. Fischera LP-0031L (ČSN EN ISO 12937) Weglowodory ciekle Oznaczanie zawartosci wody metoda kulometryczna Karla Fischera Kapalne uhlovodiky Stanoveni obsahu vody coulometrickou metodou K. Fischera LP-0031L (CSN EN ISO 12937)","search_en":"Liquid hydrocarbons Determination of water – Coulometric Karl Fischer titration method LP-0031L (ČSN EN ISO 12937)","search_zh":"液态烃 库仑卡尔·费休法测定水含量 LP-0031L (ČSN EN ISO 12937)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"72fc379ddfdbe6a69d09d455","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"20","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie temperatury mętnienia analizatorem automatycznym","methodology_en":"Determination of cloud point by automatic analyzer","methodology_zh":"自动分析仪测定浊点","methodology_cs":"Stanovení bodu zákalu automatickým analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury mętnienia analizatorem automatycznym","reference":"LP-0011L (ASTM D7689; ČSN EN ISO 3015)","norm_bases":["LP-0011L","ASTM D7689","ČSN EN ISO 3015"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie temperatury mętnienia analizatorem automatycznym Motorová paliva Stanovení bodu zákalu automatickým analyzátorem LP-0011L (ASTM D7689; ČSN EN ISO 3015) Paliwa silnikowe Oznaczanie temperatury metnienia analizatorem automatycznym Motorova paliva Stanoveni bodu zakalu automatickym analyzatorem LP-0011L (ASTM D7689; CSN EN ISO 3015)","search_en":"Motor fuels Determination of cloud point by automatic analyzer LP-0011L (ASTM D7689; ČSN EN ISO 3015)","search_zh":"发动机燃料 自动分析仪测定浊点 LP-0011L (ASTM D7689; ČSN EN ISO 3015)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75c8d07599f4621aab934744","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"21","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie wartości opałowej kalorymetrem","methodology_en":"Determination of net calorific value by calorimeter","methodology_zh":"量热计测定低位发热量","methodology_cs":"Stanovení výhřevnosti kalorimetrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wartości opałowej kalorymetrem","reference":"LP-0067L (ASTM D240)","norm_bases":["LP-0067L","ASTM D240"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie wartości opałowej kalorymetrem Kapalné uhlovodíky Stanovení výhřevnosti kalorimetrem LP-0067L (ASTM D240) Weglowodory ciekle Oznaczanie wartosci opalowej kalorymetrem Kapalne uhlovodiky Stanoveni vyhrevnosti kalorimetrem LP-0067L (ASTM D240)","search_en":"Liquid hydrocarbons Determination of net calorific value by calorimeter LP-0067L (ASTM D240)","search_zh":"液态烃 量热计测定低位发热量 LP-0067L (ASTM D240)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e8228e3ea574e952dd0fb73c","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"22","test_object":"Nafta lotnicza (paliwo lotnicze)","test_object_en":"Aviation fuel","test_object_zh":"航空煤油","test_object_cs":"Letecký petrolej","methodology":"Oznaczanie węglowodorów aromatycznych metodą HPLC","methodology_en":"Determination of aromatic hydrocarbons by HPLC method","methodology_zh":"HPLC法测定芳烃","methodology_cs":"Stanovení aromatických uhlovodíků metodou HPLC","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów aromatycznych metodą HPLC","reference":"LP-0120L (ČSN EN 12916; ASTM D 6379)","norm_bases":["LP-0120L","ČSN EN 12916","ASTM D 6379"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nafta lotnicza (paliwo lotnicze) Oznaczanie węglowodorów aromatycznych metodą HPLC Letecký petrolej Stanovení aromatických uhlovodíků metodou HPLC LP-0120L (ČSN EN 12916; ASTM D 6379) Nafta lotnicza (paliwo lotnicze) Oznaczanie weglowodorow aromatycznych metoda HPLC Letecky petrolej Stanoveni aromatickych uhlovodiku metodou HPLC LP-0120L (CSN EN 12916; ASTM D 6379)","search_en":"Aviation fuel Determination of aromatic hydrocarbons by HPLC method LP-0120L (ČSN EN 12916; ASTM D 6379)","search_zh":"航空煤油 HPLC法测定芳烃 LP-0120L (ČSN EN 12916; ASTM D 6379)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2ac00054009c7324f56e22e7","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"23","test_object":"Nafta lotnicza (paliwo lotnicze)","test_object_en":"Aviation fuel","test_object_zh":"航空煤油","test_object_cs":"Letecký petrolej","methodology":"Oznaczanie temperatury zapłonu metodą Taga","methodology_en":"Determination of flash point acc. to Tag","methodology_zh":"泰格法闪点测定","methodology_cs":"Stanovení bodu vzplanutí dle Taga","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury zapłonu metodą Taga","reference":"LP-0009L (ASTM D56)","norm_bases":["LP-0009L","ASTM D56"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nafta lotnicza (paliwo lotnicze) Oznaczanie temperatury zapłonu metodą Taga Letecký petrolej Stanovení bodu vzplanutí dle Taga LP-0009L (ASTM D56) Nafta lotnicza (paliwo lotnicze) Oznaczanie temperatury zaplonu metoda Taga Letecky petrolej Stanoveni bodu vzplanuti dle Taga LP-0009L (ASTM D56)","search_en":"Aviation fuel Determination of flash point acc. to Tag LP-0009L (ASTM D56)","search_zh":"航空煤油 泰格法闪点测定 LP-0009L (ASTM D56)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77ed194755236bcc91e365d4","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"24","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem","methodology_en":"Determination of derived cetane number (DCN) by analyzer","methodology_zh":"分析仪测定导出十六烷值（DCN）","methodology_cs":"Stanovení odvozeného cetanového čísla (DCN) analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem","reference":"LP-0235L (ASTM D 7668)","norm_bases":["LP-0235L","ASTM D 7668"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem Motorová paliva Stanovení odvozeného cetanového čísla (DCN) analyzátorem LP-0235L (ASTM D 7668) Paliwa silnikowe Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem Motorova paliva Stanoveni odvozeneho cetanoveho cisla (DCN) analyzatorem LP-0235L (ASTM D 7668)","search_en":"Motor fuels Determination of derived cetane number (DCN) by analyzer LP-0235L (ASTM D 7668)","search_zh":"发动机燃料 分析仪测定导出十六烷值（DCN） LP-0235L (ASTM D 7668)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fb2b3dcd6cd3b04d3cd53aed","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"25","test_object":"Gazowe mieszaniny węglowodorów, LPG","test_object_en":"Gaseous hydrocarbon mixtures, LPG","test_object_zh":"气态烃混合物、液化石油气","test_object_cs":"Plynné uhlovodíkové směsi, LPG","methodology":"Oznaczanie węglowodorów C1 – C5 metodą GC/FID","methodology_en":"Determination of hydrocarbons C1 – C5 by GC/FID method","methodology_zh":"GC/FID法测定C1 – C5烃","methodology_cs":"Stanovení uhlovodíků C1 – C5 metodou GC/FID","parameters":[{"name":"Metan","range":""},{"name":"Etan","range":""},{"name":"Etylen","range":""},{"name":"Propan","range":""},{"name":"Propylen","range":""},{"name":"Izobutan","range":""},{"name":"n-Butan","range":""},{"name":"trans-Buten","range":""},{"name":"n-Buten","range":""},{"name":"Izobuten","range":""},{"name":"cis-Buten","range":""},{"name":"Izopentan","range":""},{"name":"n-Pentan","range":""}],"parameters_en":[{"name":"Methane","range":""},{"name":"Ethane","range":""},{"name":"Ethylene","range":""},{"name":"Propane","range":""},{"name":"Propylene","range":""},{"name":"Isobutane","range":""},{"name":"n-Butane","range":""},{"name":"t-Butene","range":""},{"name":"n-Butene","range":""},{"name":"i-Butene","range":""},{"name":"c-Butene","range":""},{"name":"Isopentane","range":""},{"name":"n-Pentane","range":""}],"parameters_zh":[{"name":"甲烷","range":""},{"name":"乙烷","range":""},{"name":"乙烯","range":""},{"name":"丙烷","range":""},{"name":"丙烯","range":""},{"name":"异丁烷","range":""},{"name":"正丁烷","range":""},{"name":"反丁烯","range":""},{"name":"正丁烯","range":""},{"name":"异丁烯","range":""},{"name":"顺丁烯","range":""},{"name":"异戊烷","range":""},{"name":"正戊烷","range":""}],"parameters_cs":[{"name":"metan","range":""},{"name":"etan","range":""},{"name":"etylen","range":""},{"name":"propan","range":""},{"name":"propylen","range":""},{"name":"isobutan","range":""},{"name":"n-butan","range":""},{"name":"t-buten","range":""},{"name":"n-buten","range":""},{"name":"i-buten","range":""},{"name":"c-buten","range":""},{"name":"isopentan","range":""},{"name":"n-pentan","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C1 – C5 metodą GC/FID\nZakres:\nMetan\nEtan\nEtylen\nPropan\nPropylen\nIzobutan\nn-Butan\ntrans-Buten\nn-Buten\nIzobuten\ncis-Buten\nIzopentan\nn-Pentan","reference":"LP-0075L (ČSN EN 27941)","norm_bases":["LP-0075L","ČSN EN 27941"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gazowe mieszaniny węglowodorów, LPG Oznaczanie węglowodorów C1 – C5 metodą GC/FID Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Plynné uhlovodíkové směsi, LPG Stanovení uhlovodíků C1 – C5 metodou GC/FID metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  LP-0075L (ČSN EN 27941) Gazowe mieszaniny weglowodorow, LPG Oznaczanie weglowodorow C1 – C5 metoda GC/FID Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Plynne uhlovodikove smesi, LPG Stanoveni uhlovodiku C1 – C5 metodou GC/FID metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  LP-0075L (CSN EN 27941)","search_en":"Gaseous hydrocarbon mixtures, LPG Determination of hydrocarbons C1 – C5 by GC/FID method Methane  Ethane  Ethylene  Propane  Propylene  Isobutane  n-Butane  t-Butene  n-Butene  i-Butene  c-Butene  Isopentane  n-Pentane  LP-0075L (ČSN EN 27941)","search_zh":"气态烃混合物、液化石油气 GC/FID法测定C1 – C5烃 甲烷  乙烷  乙烯  丙烷  丙烯  异丁烷  正丁烷  反丁烯  正丁烯  异丁烯  顺丁烯  异戊烷  正戊烷  LP-0075L (ČSN EN 27941)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c9b72cd3d7113f996ccdf0fc","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"1","test_object":"Produkty naftowe","test_object_en":"Petroleum products","test_object_zh":"石油产品","test_object_cs":"Ropné produkty","methodology":"Pobieranie próbek produktów naftowych","methodology_en":"Sampling of petroleum products","methodology_zh":"石油产品采样","methodology_cs":"Odběr vzorků ropných produktů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek produktów naftowych","reference":"LP-0251L (ČSN EN ISO 3170)","norm_bases":["LP-0251L","ČSN EN ISO 3170"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Produkty naftowe Pobieranie próbek produktów naftowych Ropné produkty Odběr vzorků ropných produktů LP-0251L (ČSN EN ISO 3170) Produkty naftowe Pobieranie probek produktow naftowych Ropne produkty Odber vzorku ropnych produktu LP-0251L (CSN EN ISO 3170)","search_en":"Petroleum products Sampling of petroleum products LP-0251L (ČSN EN ISO 3170)","search_zh":"石油产品 石油产品采样 LP-0251L (ČSN EN ISO 3170)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f9f2090c67b5152c3d122955","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków","methodology_en":"Sampling of waste water","methodology_zh":"废水采样","methodology_cs":"Odběr vzorků odpadních vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków","reference":"LP-0253L (ČSN ISO 5667-10)","norm_bases":["LP-0253L","ČSN ISO 5667-10"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków Odpadní vody Odběr vzorků odpadních vod LP-0253L (ČSN ISO 5667-10) Scieki Pobieranie probek sciekow Odpadni vody Odber vzorku odpadnich vod LP-0253L (CSN ISO 5667-10)","search_en":"Waste water Sampling of waste water LP-0253L (ČSN ISO 5667-10)","search_zh":"废水 废水采样 LP-0253L (ČSN ISO 5667-10)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8c05f3e476b5e5d1b388e5f4","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"3","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek wód powierzchniowych","methodology_en":"Sampling of surface water","methodology_zh":"地表水采样","methodology_cs":"Odběr vzorků povrchových vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych","reference":"LP-0253L, postup B ČSN ISO 5667-4)","norm_bases":["LP-0253L, postup B","ČSN ISO 5667-4"],"lab_section":"Laboratoria Litvínov","lab_section_en":"Litvínov Laboratories","lab_section_zh":"利特维诺夫实验室","lab_section_cs":"Laboratoře Litvínov","lab_address":"Záluží 1, 436 70 Litvínov","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych Povrchové vody Odběr vzorků povrchových vod LP-0253L, postup B ČSN ISO 5667-4) Wody powierzchniowe Pobieranie probek wod powierzchniowych Povrchove vody Odber vzorku povrchovych vod LP-0253L, postup B CSN ISO 5667-4)","search_en":"Surface water Sampling of surface water LP-0253L, postup B ČSN ISO 5667-4)","search_zh":"地表水 地表水采样 LP-0253L, postup B ČSN ISO 5667-4)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"946f0cdef95e2762c3db5e77","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"1","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie krzywej destylacji pod ciśnieniem atmosferycznym","methodology_en":"Determination of distillation characteristics at atmospheric pressure","methodology_zh":"常压蒸馏特性测定","methodology_cs":"Stanovení destilační křivky při atmosférickém tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie krzywej destylacji pod ciśnieniem atmosferycznym","reference":"LP-0013K (ČSN EN ISO 3405; ASTM D86)","norm_bases":["LP-0013K","ČSN EN ISO 3405","ASTM D86"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie krzywej destylacji pod ciśnieniem atmosferycznym Kapalné uhlovodíky Stanovení destilační křivky při atmosférickém tlaku LP-0013K (ČSN EN ISO 3405; ASTM D86) Weglowodory ciekle Oznaczanie krzywej destylacji pod cisnieniem atmosferycznym Kapalne uhlovodiky Stanoveni destilacni krivky pri atmosferickem tlaku LP-0013K (CSN EN ISO 3405; ASTM D86)","search_en":"Liquid hydrocarbons Determination of distillation characteristics at atmospheric pressure LP-0013K (ČSN EN ISO 3405; ASTM D86)","search_zh":"液态烃 常压蒸馏特性测定 LP-0013K (ČSN EN ISO 3405; ASTM D86)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f903774d2968506046d8743","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"2","test_object":"Woda podziemna, ścieki","test_object_en":"Ground water, waste water","test_object_zh":"地下水、废水","test_object_cs":"Podzemní voda, odpadní voda","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FLD","methodology_en":"Determination of polyaromatic hydrocarbons by HPLC/FLD method","methodology_zh":"HPLC/FLD法测定多环芳烃","methodology_cs":"Stanovení polyaromatických uhlovodíků metodou HPLC/FLD","parameters":[{"name":"Fluoranten","range":""},{"name":"Benzo[b]fluoranten","range":""},{"name":"Benzo[k]fluoranten","range":""},{"name":"Benzo[a]piren","range":""},{"name":"Benzo[ghi]perylen","range":""},{"name":"Indeno[1,2,3-cd]piren","range":""}],"parameters_en":[{"name":"Fluoranthene","range":""},{"name":"Benzo[b]fluoranthene","range":""},{"name":"Benzo[k]fluoranthene","range":""},{"name":"Benzo[a]pyrene","range":""},{"name":"Benzo[ghi]perylene","range":""},{"name":"Indeno[1,2,3-cd]pyrene","range":""}],"parameters_zh":[{"name":"荧蒽","range":""},{"name":"苯并[b]荧蒽","range":""},{"name":"苯并[k]荧蒽","range":""},{"name":"苯并[a]芘","range":""},{"name":"苯并[ghi]苝","range":""},{"name":"茚并[1,2,3-cd]芘","range":""}],"parameters_cs":[{"name":"fluoranthen","range":""},{"name":"benzo[b]fluoranthen","range":""},{"name":"benzo[k]fluoranthen","range":""},{"name":"benzo[a]pyren","range":""},{"name":"benzo[ghi]perylen","range":""},{"name":"indeno[1,2,3-cd]pyren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["Suma 6 WWA (z obliczeń)"],"computed_en":["Sum of 6 PAH by calculation"],"computed_zh":["6种多环芳烃总和（计算）"],"computed_cs":["suma 6 PAU dopočtem"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FLD\nZakres:\nFluoranten\nBenzo[b]fluoranten\nBenzo[k]fluoranten\nBenzo[a]piren\nBenzo[ghi]perylen\nIndeno[1,2,3-cd]piren","reference":"LP-0140K (ČSN 75 7554)","norm_bases":["LP-0140K","ČSN 75 7554"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna, ścieki Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FLD Fluoranten  Benzo[b]fluoranten  Benzo[k]fluoranten  Benzo[a]piren  Benzo[ghi]perylen  Indeno[1,2,3-cd]piren  Suma 6 WWA (z obliczeń) Podzemní voda, odpadní voda Stanovení polyaromatických uhlovodíků metodou HPLC/FLD fluoranthen  benzo[b]fluoranthen  benzo[k]fluoranthen  benzo[a]pyren  benzo[ghi]perylen  indeno[1,2,3-cd]pyren  suma 6 PAU dopočtem LP-0140K (ČSN 75 7554) Woda podziemna, scieki Oznaczanie wielopierscieniowych weglowodorow aromatycznych metoda HPLC/FLD Fluoranten  Benzo[b]fluoranten  Benzo[k]fluoranten  Benzo[a]piren  Benzo[ghi]perylen  Indeno[1,2,3-cd]piren  Suma 6 WWA (z obliczen) Podzemni voda, odpadni voda Stanoveni polyaromatickych uhlovodiku metodou HPLC/FLD fluoranthen  benzo[b]fluoranthen  benzo[k]fluoranthen  benzo[a]pyren  benzo[ghi]perylen  indeno[1,2,3-cd]pyren  suma 6 PAU dopoctem LP-0140K (CSN 75 7554)","search_en":"Ground water, waste water Determination of polyaromatic hydrocarbons by HPLC/FLD method Fluoranthene  Benzo[b]fluoranthene  Benzo[k]fluoranthene  Benzo[a]pyrene  Benzo[ghi]perylene  Indeno[1,2,3-cd]pyrene  Sum of 6 PAH by calculation LP-0140K (ČSN 75 7554)","search_zh":"地下水、废水 HPLC/FLD法测定多环芳烃 荧蒽  苯并[b]荧蒽  苯并[k]荧蒽  苯并[a]芘  苯并[ghi]苝  茚并[1,2,3-cd]芘  6种多环芳烃总和（计算） LP-0140K (ČSN 75 7554)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29d87ec578473a48f20b3a8e","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"3","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie lepkości kinematycznej wiskozymetrem Stabingera","methodology_en":"Determination of kinematic viscosity by Stabinger viscometer","methodology_zh":"Stabinger粘度计测定运动粘度","methodology_cs":"Stanovení kinematické viskozity na přístroji Stabinger","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lepkości kinematycznej wiskozymetrem Stabingera","reference":"LP-0040K (ASTM D7042)","norm_bases":["LP-0040K","ASTM D7042"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie lepkości kinematycznej wiskozymetrem Stabingera Kapalné uhlovodíky Stanovení kinematické viskozity na přístroji Stabinger LP-0040K (ASTM D7042) Weglowodory ciekle Oznaczanie lepkosci kinematycznej wiskozymetrem Stabingera Kapalne uhlovodiky Stanoveni kinematicke viskozity na pristroji Stabinger LP-0040K (ASTM D7042)","search_en":"Liquid hydrocarbons Determination of kinematic viscosity by Stabinger viscometer LP-0040K (ASTM D7042)","search_zh":"液态烃 Stabinger粘度计测定运动粘度 LP-0040K (ASTM D7042)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9140bcb3bc1d7f7074dca491","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"4","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie prężności par nasyconych i obliczenie DVPE","methodology_en":"Determination of saturated vapour pressure and calculation of DVPE","methodology_zh":"饱和蒸气压测定及DVPE计算","methodology_cs":"Stanovení tlaku nasycených par a dopočet DVPE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prężności par nasyconych i obliczenie DVPE","reference":"LP-0021K (ČSN EN 13016-1)","norm_bases":["LP-0021K","ČSN EN 13016-1"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie prężności par nasyconych i obliczenie DVPE Kapalné uhlovodíky Stanovení tlaku nasycených par a dopočet DVPE LP-0021K (ČSN EN 13016-1) Weglowodory ciekle Oznaczanie preznosci par nasyconych i obliczenie DVPE Kapalne uhlovodiky Stanoveni tlaku nasycenych par a dopocet DVPE LP-0021K (CSN EN 13016-1)","search_en":"Liquid hydrocarbons Determination of saturated vapour pressure and calculation of DVPE LP-0021K (ČSN EN 13016-1)","search_zh":"液态烃 饱和蒸气压测定及DVPE计算 LP-0021K (ČSN EN 13016-1)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6d3e629acb6cb47178a9de7b","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"5","test_object":"Paliwa silnikowe i oleje opałowe","test_object_en":"Motor fuels and heating oils","test_object_zh":"发动机燃料和燃料油","test_object_cs":"Motorová paliva a topné oleje","methodology":"Oznaczanie temperatury zapłonu w tyglu zamkniętym – metoda Pensky’ego-Martensa","methodology_en":"Determination of flash point – Pensky-Martens closed cup","methodology_zh":"闭口杯闪点测定 – 宾斯基-马丁法","methodology_cs":"Stanovení bodu vzplanutí v uzavřeném kelímku – Pensky – Martens","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury zapłonu w tyglu zamkniętym – metoda Pensky’ego-Martensa","reference":"LP-0023K (ČSN EN ISO 2719)","norm_bases":["LP-0023K","ČSN EN ISO 2719"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe i oleje opałowe Oznaczanie temperatury zapłonu w tyglu zamkniętym – metoda Pensky’ego-Martensa Motorová paliva a topné oleje Stanovení bodu vzplanutí v uzavřeném kelímku – Pensky – Martens LP-0023K (ČSN EN ISO 2719) Paliwa silnikowe i oleje opalowe Oznaczanie temperatury zaplonu w tyglu zamknietym – metoda Pensky’ego-Martensa Motorova paliva a topne oleje Stanoveni bodu vzplanuti v uzavrenem kelimku – Pensky – Martens LP-0023K (CSN EN ISO 2719)","search_en":"Motor fuels and heating oils Determination of flash point – Pensky-Martens closed cup LP-0023K (ČSN EN ISO 2719)","search_zh":"发动机燃料和燃料油 闭口杯闪点测定 – 宾斯基-马丁法 LP-0023K (ČSN EN ISO 2719)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ce2e30e75819a8de49041a80","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"6","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie estrów metylowych kwasów tłuszczowych (FAME) metodą IR","methodology_en":"Determination of fatty acid methyl esters (FAME) by IR method","methodology_zh":"红外法测定脂肪酸甲酯（FAME）","methodology_cs":"Stanovení methylesterů mastných kyselin (FAME) metodou IČ","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie estrów metylowych kwasów tłuszczowych (FAME) metodą IR","reference":"LP-0244K (ČSN EN 14078; ASTM D7371)","norm_bases":["LP-0244K","ČSN EN 14078","ASTM D7371"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie estrów metylowych kwasów tłuszczowych (FAME) metodą IR Motorová paliva Stanovení methylesterů mastných kyselin (FAME) metodou IČ LP-0244K (ČSN EN 14078; ASTM D7371) Paliwa silnikowe Oznaczanie estrow metylowych kwasow tluszczowych (FAME) metoda IR Motorova paliva Stanoveni methylesteru mastnych kyselin (FAME) metodou IC LP-0244K (CSN EN 14078; ASTM D7371)","search_en":"Motor fuels Determination of fatty acid methyl esters (FAME) by IR method LP-0244K (ČSN EN 14078; ASTM D7371)","search_zh":"发动机燃料 红外法测定脂肪酸甲酯（FAME） LP-0244K (ČSN EN 14078; ASTM D7371)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d7ec13335c58537d2a4015bb","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"7","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości grup węglowodorów, benzenu i związków tlenowych metodą wielowymiarowej GC/FID","methodology_en":"Determination of the content of hydrocarbon groups, benzene and oxygenates by multidimensional GC/FID method","methodology_zh":"多维GC/FID法测定烃族组成、苯和含氧化合物含量","methodology_cs":"Stanovení obsahu skupin uhlovodíků, benzenu a kyslíkatých látek metodou multidimenzionální GC/FID","parameters":[{"name":"Benzen","range":""},{"name":"Metanol","range":""},{"name":"Etanol","range":""},{"name":"Alkohol izopropylowy","range":""},{"name":"Alkohol izobutylowy","range":""},{"name":"Alkohol tert-butylowy","range":""},{"name":"Eter metylowo-tert-butylowy (MTBE)","range":""},{"name":"Eter etylowo-tert-butylowy (ETBE)","range":""},{"name":"Węglowodory aromatyczne","range":""},{"name":"Olefiny","range":""},{"name":"Całkowita zawartość tlenu","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"Methanol","range":""},{"name":"Ethanol","range":""},{"name":"Isopropyl alcohol","range":""},{"name":"Isobutyl alcohol","range":""},{"name":"tert-Butyl alcohol","range":""},{"name":"Methyl tert-butyl ether (MTBE)","range":""},{"name":"Ethyl tert-butyl ether (ETBE)","range":""},{"name":"Aromatics","range":""},{"name":"Olefins","range":""},{"name":"Total oxygen content","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲醇","range":""},{"name":"乙醇","range":""},{"name":"异丙醇","range":""},{"name":"异丁醇","range":""},{"name":"叔丁醇","range":""},{"name":"甲基叔丁基醚（MTBE）","range":""},{"name":"乙基叔丁基醚（ETBE）","range":""},{"name":"芳烃","range":""},{"name":"烯烃","range":""},{"name":"总氧含量","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"methanol","range":""},{"name":"ethanol","range":""},{"name":"isopropylalkohol","range":""},{"name":"isobutylalkohol","range":""},{"name":"tercbutylalkohol","range":""},{"name":"methyltercbutylether (MTBE)","range":""},{"name":"ethyltercbutylether (ETBE)","range":""},{"name":"aromáty","range":""},{"name":"olefíny","range":""},{"name":"celkový obsah kyslíku","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości grup węglowodorów, benzenu i związków tlenowych metodą wielowymiarowej GC/FID\nZakres:\nBenzen\nMetanol\nEtanol\nAlkohol izopropylowy\nAlkohol izobutylowy\nAlkohol tert-butylowy\nEter metylowo-tert-butylowy (MTBE)\nEter etylowo-tert-butylowy (ETBE)\nWęglowodory aromatyczne\nOlefiny\nCałkowita zawartość tlenu","reference":"LP-0063RK (ČSN EN ISO 22854)","norm_bases":["LP-0063RK","ČSN EN ISO 22854"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości grup węglowodorów, benzenu i związków tlenowych metodą wielowymiarowej GC/FID Benzen  Metanol  Etanol  Alkohol izopropylowy  Alkohol izobutylowy  Alkohol tert-butylowy  Eter metylowo-tert-butylowy (MTBE)  Eter etylowo-tert-butylowy (ETBE)  Węglowodory aromatyczne  Olefiny  Całkowita zawartość tlenu  Kapalné uhlovodíky Stanovení obsahu skupin uhlovodíků, benzenu a kyslíkatých látek metodou multidimenzionální GC/FID benzen  methanol  ethanol  isopropylalkohol  isobutylalkohol  tercbutylalkohol  methyltercbutylether (MTBE)  ethyltercbutylether (ETBE)  aromáty  olefíny  celkový obsah kyslíku  LP-0063RK (ČSN EN ISO 22854) Weglowodory ciekle Oznaczanie zawartosci grup weglowodorow, benzenu i zwiazkow tlenowych metoda wielowymiarowej GC/FID Benzen  Metanol  Etanol  Alkohol izopropylowy  Alkohol izobutylowy  Alkohol tert-butylowy  Eter metylowo-tert-butylowy (MTBE)  Eter etylowo-tert-butylowy (ETBE)  Weglowodory aromatyczne  Olefiny  Calkowita zawartosc tlenu  Kapalne uhlovodiky Stanoveni obsahu skupin uhlovodiku, benzenu a kyslikatych latek metodou multidimenzionalni GC/FID benzen  methanol  ethanol  isopropylalkohol  isobutylalkohol  tercbutylalkohol  methyltercbutylether (MTBE)  ethyltercbutylether (ETBE)  aromaty  olefiny  celkovy obsah kysliku  LP-0063RK (CSN EN ISO 22854)","search_en":"Liquid hydrocarbons Determination of the content of hydrocarbon groups, benzene and oxygenates by multidimensional GC/FID method Benzene  Methanol  Ethanol  Isopropyl alcohol  Isobutyl alcohol  tert-Butyl alcohol  Methyl tert-butyl ether (MTBE)  Ethyl tert-butyl ether (ETBE)  Aromatics  Olefins  Total oxygen content  LP-0063RK (ČSN EN ISO 22854)","search_zh":"液态烃 多维GC/FID法测定烃族组成、苯和含氧化合物含量 苯  甲醇  乙醇  异丙醇  异丁醇  叔丁醇  甲基叔丁基醚（MTBE）  乙基叔丁基醚（ETBE）  芳烃  烯烃  总氧含量  LP-0063RK (ČSN EN ISO 22854)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"548cfbb66913090225243a97","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"8","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie węglowodorów C10 - C40 metodą GC/FID","methodology_en":"Determination of hydrocarbons C10 – C40 by GC/FID method","methodology_zh":"GC/FID法测定C10 - C40烃","methodology_cs":"Stanovení uhlovodíků C10 - C40 metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10 - C40 metodą GC/FID","reference":"LP-0164K (ČSN EN ISO 9377-2)","norm_bases":["LP-0164K","ČSN EN ISO 9377-2"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie węglowodorów C10 - C40 metodą GC/FID Odpadní vody Stanovení uhlovodíků C10 - C40 metodou GC/FID LP-0164K (ČSN EN ISO 9377-2) Scieki Oznaczanie weglowodorow C10 - C40 metoda GC/FID Odpadni vody Stanoveni uhlovodiku C10 - C40 metodou GC/FID LP-0164K (CSN EN ISO 9377-2)","search_en":"Waste water Determination of hydrocarbons C10 – C40 by GC/FID method LP-0164K (ČSN EN ISO 9377-2)","search_zh":"废水 GC/FID法测定C10 - C40烃 LP-0164K (ČSN EN ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"566b13c2f8fc3ebee68c7cfb","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"9","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości siarki metodą fluorescencji w nadfiolecie (UV)","methodology_en":"Determination of sulphur content by UV fluorescence method","methodology_zh":"紫外荧光法测定硫含量","methodology_cs":"Stanovení obsahu síry metodou UV fluorescence","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości siarki metodą fluorescencji w nadfiolecie (UV)","reference":"LP-0025K (ČSN EN ISO 20846; ASTM D5453)","norm_bases":["LP-0025K","ČSN EN ISO 20846","ASTM D5453"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości siarki metodą fluorescencji w nadfiolecie (UV) Kapalné uhlovodíky Stanovení obsahu síry metodou UV fluorescence LP-0025K (ČSN EN ISO 20846; ASTM D5453) Weglowodory ciekle Oznaczanie zawartosci siarki metoda fluorescencji w nadfiolecie (UV) Kapalne uhlovodiky Stanoveni obsahu siry metodou UV fluorescence LP-0025K (CSN EN ISO 20846; ASTM D5453)","search_en":"Liquid hydrocarbons Determination of sulphur content by UV fluorescence method LP-0025K (ČSN EN ISO 20846; ASTM D5453)","search_zh":"液态烃 紫外荧光法测定硫含量 LP-0025K (ČSN EN ISO 20846; ASTM D5453)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"359960e36750d1cd1246383a","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"10","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie gęstości densymetrem (gęstościomierzem oscylacyjnym)","methodology_en":"Determination of density by densitometer","methodology_zh":"密度计测定密度","methodology_cs":"Stanovení hustoty denzitometrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości densymetrem (gęstościomierzem oscylacyjnym)","reference":"LP-0008KA (ČSN EN ISO 12185)","norm_bases":["LP-0008KA","ČSN EN ISO 12185"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie gęstości densymetrem (gęstościomierzem oscylacyjnym) Kapalné uhlovodíky Stanovení hustoty denzitometrem LP-0008KA (ČSN EN ISO 12185) Weglowodory ciekle Oznaczanie gestosci densymetrem (gestosciomierzem oscylacyjnym) Kapalne uhlovodiky Stanoveni hustoty denzitometrem LP-0008KA (CSN EN ISO 12185)","search_en":"Liquid hydrocarbons Determination of density by densitometer LP-0008KA (ČSN EN ISO 12185)","search_zh":"液态烃 密度计测定密度 LP-0008KA (ČSN EN ISO 12185)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2221e0cc0afdef1d16d9d95a","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"11","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie gęstości areometrem szklanym","methodology_en":"Determination of density by glass densitometer","methodology_zh":"玻璃比重计测定密度","methodology_cs":"Stanovení hustoty skleněným hustoměrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości areometrem szklanym","reference":"LP 0008KB (ČSN EN ISO 3675)","norm_bases":["LP 0008KB","ČSN EN ISO 3675"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie gęstości areometrem szklanym Kapalné uhlovodíky Stanovení hustoty skleněným hustoměrem LP 0008KB (ČSN EN ISO 3675) Weglowodory ciekle Oznaczanie gestosci areometrem szklanym Kapalne uhlovodiky Stanoveni hustoty sklenenym hustomerem LP 0008KB (CSN EN ISO 3675)","search_en":"Liquid hydrocarbons Determination of density by glass densitometer LP 0008KB (ČSN EN ISO 3675)","search_zh":"液态烃 玻璃比重计测定密度 LP 0008KB (ČSN EN ISO 3675)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e736818cb82ed07832eebe25","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"12","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości wody metodą miareczkową Karla Fischera","methodology_en":"Determination of water content by titration – Karl Fischer method","methodology_zh":"卡尔·费休滴定法测定水含量","methodology_cs":"Stanovení obsahu vody titrační metodou K. Fischera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wody metodą miareczkową Karla Fischera","reference":"LP-0037K (ČSN ISO 760)","norm_bases":["LP-0037K","ČSN ISO 760"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości wody metodą miareczkową Karla Fischera Kapalné uhlovodíky Stanovení obsahu vody titrační metodou K. Fischera LP-0037K (ČSN ISO 760) Weglowodory ciekle Oznaczanie zawartosci wody metoda miareczkowa Karla Fischera Kapalne uhlovodiky Stanoveni obsahu vody titracni metodou K. Fischera LP-0037K (CSN ISO 760)","search_en":"Liquid hydrocarbons Determination of water content by titration – Karl Fischer method LP-0037K (ČSN ISO 760)","search_zh":"液态烃 卡尔·费休滴定法测定水含量 LP-0037K (ČSN ISO 760)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2db0c681b0cac938b26fd760","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"13","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym","methodology_en":"Determination of cold filter plugging point (CFPP) using an automatic analyzer","methodology_zh":"自动分析仪测定冷滤点（CFPP）","methodology_cs":"Stanovení filtrovatelnosti (CFPP) automatickým analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym","reference":"LP-0012K (ČSN EN 116; ASTM D6371)","norm_bases":["LP-0012K","ČSN EN 116","ASTM D6371"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym Motorová paliva Stanovení filtrovatelnosti (CFPP) automatickým analyzátorem LP-0012K (ČSN EN 116; ASTM D6371) Paliwa silnikowe Oznaczanie temperatury zablokowania zimnego filtra (CFPP) analizatorem automatycznym Motorova paliva Stanoveni filtrovatelnosti (CFPP) automatickym analyzatorem LP-0012K (CSN EN 116; ASTM D6371)","search_en":"Motor fuels Determination of cold filter plugging point (CFPP) using an automatic analyzer LP-0012K (ČSN EN 116; ASTM D6371)","search_zh":"发动机燃料 自动分析仪测定冷滤点（CFPP） LP-0012K (ČSN EN 116; ASTM D6371)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a3727a95241f7434f50353b3","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"14","test_object":"Woda podziemna, ścieki","test_object_en":"Ground water, waste water","test_object_zh":"地下水、废水","test_object_cs":"Podzemní voda, odpadní voda","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZTn) fotometrycznie z użyciem komercyjnego zestawu analitycznego","methodology_en":"Determination of biochemical oxygen demand (BODn) using a commercial analytical kit photometrically","methodology_zh":"使用商业分析试剂盒光度法测定生化需氧量（BODn）","methodology_cs":"Stanovení biologické spotřeby kyslíku (BSKn) pomocí analytické komerční soupravy fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZTn) fotometrycznie z użyciem komercyjnego zestawu analitycznego","reference":"LP-0135K (Návod firmy MERCK)","norm_bases":["LP-0135K","Návod firmy MERCK"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna, ścieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZTn) fotometrycznie z użyciem komercyjnego zestawu analitycznego Podzemní voda, odpadní voda Stanovení biologické spotřeby kyslíku (BSKn) pomocí analytické komerční soupravy fotometricky LP-0135K (Návod firmy MERCK) Woda podziemna, scieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZTn) fotometrycznie z uzyciem komercyjnego zestawu analitycznego Podzemni voda, odpadni voda Stanoveni biologicke spotreby kysliku (BSKn) pomoci analyticke komercni soupravy fotometricky LP-0135K (Navod firmy MERCK)","search_en":"Ground water, waste water Determination of biochemical oxygen demand (BODn) using a commercial analytical kit photometrically LP-0135K (Návod firmy MERCK)","search_zh":"地下水、废水 使用商业分析试剂盒光度法测定生化需氧量（BODn） LP-0135K (Návod firmy MERCK)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bb3910e1fd973ce28617b6ad","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"15","test_object":"Woda podziemna, ścieki","test_object_en":"Ground water, waste water","test_object_zh":"地下水、废水","test_object_cs":"Podzemní voda, odpadní voda","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dichromianową (ChZT-Cr) z użyciem komercyjnego zestawu analitycznego","methodology_en":"Determination of chemical oxygen demand with dichromate (COD-Cr) using a commercial analytical kit","methodology_zh":"使用商业分析试剂盒重铬酸盐法测定化学需氧量（COD-Cr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem (CHSK-Cr) pomocí analytické komerční soupravy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dichromianową (ChZT-Cr) z użyciem komercyjnego zestawu analitycznego","reference":"LP-0161K (ASTM D5220; Návod firmy MERCK)","norm_bases":["LP-0161K","ASTM D5220","Návod firmy MERCK"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna, ścieki Oznaczanie chemicznego zapotrzebowania tlenu metodą dichromianową (ChZT-Cr) z użyciem komercyjnego zestawu analitycznego Podzemní voda, odpadní voda Stanovení chemické spotřeby kyslíku dichromanem (CHSK-Cr) pomocí analytické komerční soupravy LP-0161K (ASTM D5220; Návod firmy MERCK) Woda podziemna, scieki Oznaczanie chemicznego zapotrzebowania tlenu metoda dichromianowa (ChZT-Cr) z uzyciem komercyjnego zestawu analitycznego Podzemni voda, odpadni voda Stanoveni chemicke spotreby kysliku dichromanem (CHSK-Cr) pomoci analyticke komercni soupravy LP-0161K (ASTM D5220; Navod firmy MERCK)","search_en":"Ground water, waste water Determination of chemical oxygen demand with dichromate (COD-Cr) using a commercial analytical kit LP-0161K (ASTM D5220; Návod firmy MERCK)","search_zh":"地下水、废水 使用商业分析试剂盒重铬酸盐法测定化学需氧量（COD-Cr） LP-0161K (ASTM D5220; Návod firmy MERCK)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6e57190a1fbfad0b57fcaff","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"16","test_object":"Woda podziemna, ścieki","test_object_en":"Ground water, waste water","test_object_zh":"地下水、废水","test_object_cs":"Podzemní voda, odpadní voda","methodology":"Oznaczanie zawiesiny ogólnej (substancji nierozpuszczonych) metodą wagową","methodology_en":"Determination of suspended solids by gravimetry","methodology_zh":"重量法测定悬浮物","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny ogólnej (substancji nierozpuszczonych) metodą wagową","reference":"LP-0122K (ČSN EN 872)","norm_bases":["LP-0122K","ČSN EN 872"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna, ścieki Oznaczanie zawiesiny ogólnej (substancji nierozpuszczonych) metodą wagową Podzemní voda, odpadní voda Stanovení nerozpuštěných látek gravimetricky LP-0122K (ČSN EN 872) Woda podziemna, scieki Oznaczanie zawiesiny ogolnej (substancji nierozpuszczonych) metoda wagowa Podzemni voda, odpadni voda Stanoveni nerozpustenych latek gravimetricky LP-0122K (CSN EN 872)","search_en":"Ground water, waste water Determination of suspended solids by gravimetry LP-0122K (ČSN EN 872)","search_zh":"地下水、废水 重量法测定悬浮物 LP-0122K (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8050c5704b1baf96debdea14","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"17","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie liczby oktanowej metodą badawczą","methodology_en":"Determination of knock characteristics by research method","methodology_zh":"研究法辛烷值测定","methodology_cs":"Stanovení oktanového čísla výzkumnou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby oktanowej metodą badawczą","reference":"LP-0045K (ČSN EN ISO 5164; ASTM D2699)","norm_bases":["LP-0045K","ČSN EN ISO 5164","ASTM D2699"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie liczby oktanowej metodą badawczą Motorová paliva Stanovení oktanového čísla výzkumnou metodou LP-0045K (ČSN EN ISO 5164; ASTM D2699) Paliwa silnikowe Oznaczanie liczby oktanowej metoda badawcza Motorova paliva Stanoveni oktanoveho cisla vyzkumnou metodou LP-0045K (CSN EN ISO 5164; ASTM D2699)","search_en":"Motor fuels Determination of knock characteristics by research method LP-0045K (ČSN EN ISO 5164; ASTM D2699)","search_zh":"发动机燃料 研究法辛烷值测定 LP-0045K (ČSN EN ISO 5164; ASTM D2699)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f5037aae7d32c86bf23fa5d","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"18","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie liczby oktanowej metodą motorową","methodology_en":"Determination of knock characteristics by engine method","methodology_zh":"马达法辛烷值测定","methodology_cs":"Stanovení oktanového čísla motorovou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby oktanowej metodą motorową","reference":"LP-0046K (ČSN EN ISO 5163; ASTM D2700)","norm_bases":["LP-0046K","ČSN EN ISO 5163","ASTM D2700"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie liczby oktanowej metodą motorową Motorová paliva Stanovení oktanového čísla motorovou metodou LP-0046K (ČSN EN ISO 5163; ASTM D2700) Paliwa silnikowe Oznaczanie liczby oktanowej metoda motorowa Motorova paliva Stanoveni oktanoveho cisla motorovou metodou LP-0046K (CSN EN ISO 5163; ASTM D2700)","search_en":"Motor fuels Determination of knock characteristics by engine method LP-0046K (ČSN EN ISO 5163; ASTM D2700)","search_zh":"发动机燃料 马达法辛烷值测定 LP-0046K (ČSN EN ISO 5163; ASTM D2700)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6fae351d19b0b467c9f574e3","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"19","test_object":"Gazy rafineryjne","test_object_en":"Refinery gas","test_object_zh":"炼厂气","test_object_cs":"Rafinérské plyny","methodology":"Oznaczanie składu gazów rafineryjnych metodą GC/FID/TCD","methodology_en":"Determination of refinery gas composition by GC/FID, TCD method","methodology_zh":"GC/FID/TCD法测定炼厂气组成","methodology_cs":"Stanovení složení rafinérských plynů metodou GC/FID/TCD","parameters":[{"name":"Wodór","range":""},{"name":"Azot","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"Metan","range":""},{"name":"Etan","range":""},{"name":"Etylen","range":""},{"name":"Propan","range":""},{"name":"Propylen","range":""},{"name":"Izobutan","range":""},{"name":"n-Butan","range":""},{"name":"trans-Buten","range":""},{"name":"n-Buten","range":""},{"name":"Izobuten","range":""},{"name":"cis-Buten","range":""},{"name":"Izopentan","range":""},{"name":"n-Pentan","range":""},{"name":"Węglowodory C6 i wyższe","range":""},{"name":"Suma węglowodorów","range":""},{"name":"Zawartość wody","range":""}],"parameters_en":[{"name":"Hydrogen","range":""},{"name":"Nitrogen","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"Methane","range":""},{"name":"Ethane","range":""},{"name":"Ethylene","range":""},{"name":"Propane","range":""},{"name":"Propylene","range":""},{"name":"Isobutane","range":""},{"name":"n-Butane","range":""},{"name":"t-Butene","range":""},{"name":"n-Butene","range":""},{"name":"i-Butene","range":""},{"name":"c-Butene","range":""},{"name":"Isopentane","range":""},{"name":"n-Pentane","range":""},{"name":"C6-hydrocarbons+higher","range":""},{"name":"Sum of hydrocarbons","range":""},{"name":"Water content","range":""}],"parameters_zh":[{"name":"氢","range":""},{"name":"氮","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"甲烷","range":""},{"name":"乙烷","range":""},{"name":"乙烯","range":""},{"name":"丙烷","range":""},{"name":"丙烯","range":""},{"name":"异丁烷","range":""},{"name":"正丁烷","range":""},{"name":"反丁烯","range":""},{"name":"正丁烯","range":""},{"name":"异丁烯","range":""},{"name":"顺丁烯","range":""},{"name":"异戊烷","range":""},{"name":"正戊烷","range":""},{"name":"C6及以上烃","range":""},{"name":"烃总量","range":""},{"name":"水含量","range":""}],"parameters_cs":[{"name":"vodík","range":""},{"name":"dusík","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"metan","range":""},{"name":"etan","range":""},{"name":"etylen","range":""},{"name":"propan","range":""},{"name":"propylen","range":""},{"name":"isobutan","range":""},{"name":"n-butan","range":""},{"name":"t-buten","range":""},{"name":"n-buten","range":""},{"name":"i-buten","range":""},{"name":"c-buten","range":""},{"name":"isopentan","range":""},{"name":"n-pentan","range":""},{"name":"C6-uhlovodíky+vyšší","range":""},{"name":"suma uhlovodíků","range":""},{"name":"obsah vody","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie składu gazów rafineryjnych metodą GC/FID/TCD\nZakres:\nWodór\nAzot\nCO\nCO2\nMetan\nEtan\nEtylen\nPropan\nPropylen\nIzobutan\nn-Butan\ntrans-Buten\nn-Buten\nIzobuten\ncis-Buten\nIzopentan\nn-Pentan\nWęglowodory C6 i wyższe\nSuma węglowodorów\nZawartość wody","reference":"LP-0026K (ČSN EN ISO 6974-6; ISO 7941)","norm_bases":["LP-0026K","ČSN EN ISO 6974-6","ISO 7941"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gazy rafineryjne Oznaczanie składu gazów rafineryjnych metodą GC/FID/TCD Wodór  Azot  CO  CO2  Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Węglowodory C6 i wyższe  Suma węglowodorów  Zawartość wody  Rafinérské plyny Stanovení složení rafinérských plynů metodou GC/FID/TCD vodík  dusík  CO  CO2  metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  C6-uhlovodíky+vyšší  suma uhlovodíků  obsah vody  LP-0026K (ČSN EN ISO 6974-6; ISO 7941) Gazy rafineryjne Oznaczanie skladu gazow rafineryjnych metoda GC/FID/TCD Wodor  Azot  CO  CO2  Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Weglowodory C6 i wyzsze  Suma weglowodorow  Zawartosc wody  Rafinerske plyny Stanoveni slozeni rafinerskych plynu metodou GC/FID/TCD vodik  dusik  CO  CO2  metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  C6-uhlovodiky+vyssi  suma uhlovodiku  obsah vody  LP-0026K (CSN EN ISO 6974-6; ISO 7941)","search_en":"Refinery gas Determination of refinery gas composition by GC/FID, TCD method Hydrogen  Nitrogen  CO  CO2  Methane  Ethane  Ethylene  Propane  Propylene  Isobutane  n-Butane  t-Butene  n-Butene  i-Butene  c-Butene  Isopentane  n-Pentane  C6-hydrocarbons+higher  Sum of hydrocarbons  Water content  LP-0026K (ČSN EN ISO 6974-6; ISO 7941)","search_zh":"炼厂气 GC/FID/TCD法测定炼厂气组成 氢  氮  CO  CO2  甲烷  乙烷  乙烯  丙烷  丙烯  异丁烷  正丁烷  反丁烯  正丁烯  异丁烯  顺丁烯  异戊烷  正戊烷  C6及以上烃  烃总量  水含量  LP-0026K (ČSN EN ISO 6974-6; ISO 7941)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6706ec5e79a546bbcb75778d","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"20","test_object":"Gazy rafineryjne","test_object_en":"Refinery gas","test_object_zh":"炼厂气","test_object_cs":"Rafinérské plyny","methodology":"Oznaczanie zawartości wody metodą miareczkową Karla Fischera","methodology_en":"Determination of water content by titration – Karl Fischer method","methodology_zh":"卡尔·费休滴定法测定水含量","methodology_cs":"Stanovení obsahu vody titrační metodou K. Fischera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wody metodą miareczkową Karla Fischera","reference":"LP-0037K (ČSN EN ISO 10101-2)","norm_bases":["LP-0037K","ČSN EN ISO 10101-2"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gazy rafineryjne Oznaczanie zawartości wody metodą miareczkową Karla Fischera Rafinérské plyny Stanovení obsahu vody titrační metodou K. Fischera LP-0037K (ČSN EN ISO 10101-2) Gazy rafineryjne Oznaczanie zawartosci wody metoda miareczkowa Karla Fischera Rafinerske plyny Stanoveni obsahu vody titracni metodou K. Fischera LP-0037K (CSN EN ISO 10101-2)","search_en":"Refinery gas Determination of water content by titration – Karl Fischer method LP-0037K (ČSN EN ISO 10101-2)","search_zh":"炼厂气 卡尔·费休滴定法测定水含量 LP-0037K (ČSN EN ISO 10101-2)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a43e2b7075e27248244344cf","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"21","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie wartości opałowej kalorymetrem","methodology_en":"Determination of net calorific value by calorimeter","methodology_zh":"量热计测定低位发热量","methodology_cs":"Stanovení výhřevnosti kalorimetrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wartości opałowej kalorymetrem","reference":"LP-0067K (ASTM D240)","norm_bases":["LP-0067K","ASTM D240"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie wartości opałowej kalorymetrem Kapalné uhlovodíky Stanovení výhřevnosti kalorimetrem LP-0067K (ASTM D240) Weglowodory ciekle Oznaczanie wartosci opalowej kalorymetrem Kapalne uhlovodiky Stanoveni vyhrevnosti kalorimetrem LP-0067K (ASTM D240)","search_en":"Liquid hydrocarbons Determination of net calorific value by calorimeter LP-0067K (ASTM D240)","search_zh":"液态烃 量热计测定低位发热量 LP-0067K (ASTM D240)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ecfeb662c8a473c876dc3515","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"22","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości siarki metodą fluorescencji rentgenowskiej","methodology_en":"Determination of sulphur content by X-ray fluorescence method","methodology_zh":"X射线荧光法测定硫含量","methodology_cs":"Stanovení obsahu síry metodou RTG fluorescence","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości siarki metodą fluorescencji rentgenowskiej","reference":"LP-0033K (ASTM D4294; ČSN EN ISO 8754)","norm_bases":["LP-0033K","ASTM D4294","ČSN EN ISO 8754"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości siarki metodą fluorescencji rentgenowskiej Kapalné uhlovodíky Stanovení obsahu síry metodou RTG fluorescence LP-0033K (ASTM D4294; ČSN EN ISO 8754) Weglowodory ciekle Oznaczanie zawartosci siarki metoda fluorescencji rentgenowskiej Kapalne uhlovodiky Stanoveni obsahu siry metodou RTG fluorescence LP-0033K (ASTM D4294; CSN EN ISO 8754)","search_en":"Liquid hydrocarbons Determination of sulphur content by X-ray fluorescence method LP-0033K (ASTM D4294; ČSN EN ISO 8754)","search_zh":"液态烃 X射线荧光法测定硫含量 LP-0033K (ASTM D4294; ČSN EN ISO 8754)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ff216e4f134596211b2320b","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"23","test_object":"Węglowodory ciekłe","test_object_en":"Liquid hydrocarbons","test_object_zh":"液态烃","test_object_cs":"Kapalné uhlovodíky","methodology":"Oznaczanie zawartości wody metodą kulometryczną Karla Fischera","methodology_en":"Determination of water – Coulometric Karl Fischer titration method","methodology_zh":"库仑卡尔·费休法测定水含量","methodology_cs":"Stanovení obsahu vody coulometrickou metodou K. Fischera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wody metodą kulometryczną Karla Fischera","reference":"LP-0031K (ČSN EN ISO 12937)","norm_bases":["LP-0031K","ČSN EN ISO 12937"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węglowodory ciekłe Oznaczanie zawartości wody metodą kulometryczną Karla Fischera Kapalné uhlovodíky Stanovení obsahu vody coulometrickou metodou K. Fischera LP-0031K (ČSN EN ISO 12937) Weglowodory ciekle Oznaczanie zawartosci wody metoda kulometryczna Karla Fischera Kapalne uhlovodiky Stanoveni obsahu vody coulometrickou metodou K. Fischera LP-0031K (CSN EN ISO 12937)","search_en":"Liquid hydrocarbons Determination of water – Coulometric Karl Fischer titration method LP-0031K (ČSN EN ISO 12937)","search_zh":"液态烃 库仑卡尔·费休法测定水含量 LP-0031K (ČSN EN ISO 12937)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"045786bd49034d0de0107453","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"24","test_object":"Woda podziemna, ścieki","test_object_en":"Ground water, waste water","test_object_zh":"地下水、废水","test_object_cs":"Podzemní voda, odpadní voda","methodology":"Oznaczanie MTBE i ETBE metodą GC/MS (headspace)","methodology_en":"Determination of MTBE and ETBE by GC/MS method (headspace)","methodology_zh":"GC/MS法（顶空）测定MTBE和ETBE","methodology_cs":"Stanovení MTBE a ETBE metodou GC/MS (headspace)","parameters":[{"name":"MTBE","range":""},{"name":"ETBE","range":""}],"parameters_en":[{"name":"MTBE","range":""},{"name":"ETBE","range":""}],"parameters_zh":[{"name":"MTBE","range":""},{"name":"ETBE","range":""}],"parameters_cs":[{"name":"MTBE","range":""},{"name":"ETBE","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie MTBE i ETBE metodą GC/MS (headspace)\nZakres:\nMTBE\nETBE","reference":"LP-0128K (ČSN ISO 11423-1; EPA Metod 8260B)","norm_bases":["LP-0128K","ČSN ISO 11423-1","EPA Metod 8260B"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna, ścieki Oznaczanie MTBE i ETBE metodą GC/MS (headspace) MTBE  ETBE  Podzemní voda, odpadní voda Stanovení MTBE a ETBE metodou GC/MS (headspace) MTBE  ETBE  LP-0128K (ČSN ISO 11423-1; EPA Metod 8260B) Woda podziemna, scieki Oznaczanie MTBE i ETBE metoda GC/MS (headspace) MTBE  ETBE  Podzemni voda, odpadni voda Stanoveni MTBE a ETBE metodou GC/MS (headspace) MTBE  ETBE  LP-0128K (CSN ISO 11423-1; EPA Metod 8260B)","search_en":"Ground water, waste water Determination of MTBE and ETBE by GC/MS method (headspace) MTBE  ETBE  LP-0128K (ČSN ISO 11423-1; EPA Metod 8260B)","search_zh":"地下水、废水 GC/MS法（顶空）测定MTBE和ETBE MTBE  ETBE  LP-0128K (ČSN ISO 11423-1; EPA Metod 8260B)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef4cf1053e6213fd78d3988f","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"25","test_object":"Woda podziemna, ścieki","test_object_en":"Ground water, waste water","test_object_zh":"地下水、废水","test_object_cs":"Podzemní voda, odpadní voda","methodology":"Oznaczanie BTEX metodą GC/MS (headspace)","methodology_en":"Determination of BTEX in water by GC/MS method (headspace)","methodology_zh":"GC/MS法（顶空）测定BTEX","methodology_cs":"Stanovení BTEX metodou GC/MS (headspace)","parameters":[{"name":"Benzen","range":""},{"name":"Toluen","range":""},{"name":"Etylobenzen","range":""},{"name":"o-, m-, p-Ksylen","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"Toluene","range":""},{"name":"Ethylbenzene","range":""},{"name":"o-, m-, p-Xylene","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"乙苯","range":""},{"name":"邻、间、对二甲苯","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"ethylbenzen","range":""},{"name":"o-, m-, p-xylen","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["Suma ksylenów (z obliczeń)"],"computed_en":["Total xylenes by calculation"],"computed_zh":["二甲苯总量（计算）"],"computed_cs":["suma xylenů dopočtem"],"activity":"Oznaczanie BTEX metodą GC/MS (headspace)\nZakres:\nBenzen\nToluen\nEtylobenzen\no-, m-, p-Ksylen","reference":"LP-0129K (ČSN ISO 11423-1; EPA Metod 8260B)","norm_bases":["LP-0129K","ČSN ISO 11423-1","EPA Metod 8260B"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna, ścieki Oznaczanie BTEX metodą GC/MS (headspace) Benzen  Toluen  Etylobenzen  o-, m-, p-Ksylen  Suma ksylenów (z obliczeń) Podzemní voda, odpadní voda Stanovení BTEX metodou GC/MS (headspace) benzen  toluen  ethylbenzen  o-, m-, p-xylen  suma xylenů dopočtem LP-0129K (ČSN ISO 11423-1; EPA Metod 8260B) Woda podziemna, scieki Oznaczanie BTEX metoda GC/MS (headspace) Benzen  Toluen  Etylobenzen  o-, m-, p-Ksylen  Suma ksylenow (z obliczen) Podzemni voda, odpadni voda Stanoveni BTEX metodou GC/MS (headspace) benzen  toluen  ethylbenzen  o-, m-, p-xylen  suma xylenu dopoctem LP-0129K (CSN ISO 11423-1; EPA Metod 8260B)","search_en":"Ground water, waste water Determination of BTEX in water by GC/MS method (headspace) Benzene  Toluene  Ethylbenzene  o-, m-, p-Xylene  Total xylenes by calculation LP-0129K (ČSN ISO 11423-1; EPA Metod 8260B)","search_zh":"地下水、废水 GC/MS法（顶空）测定BTEX 苯  甲苯  乙苯  邻、间、对二甲苯  二甲苯总量（计算） LP-0129K (ČSN ISO 11423-1; EPA Metod 8260B)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5907645ccc1c4a0635e419ed","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"26","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie temperatury mętnienia analizatorem automatycznym","methodology_en":"Determination of cloud point by automatic analyzer","methodology_zh":"自动分析仪测定浊点","methodology_cs":"Stanovení bodu zákalu automatickým analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury mętnienia analizatorem automatycznym","reference":"LP-0011K (ASTM D5771; ČSN EN ISO 3015)","norm_bases":["LP-0011K","ASTM D5771","ČSN EN ISO 3015"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie temperatury mętnienia analizatorem automatycznym Motorová paliva Stanovení bodu zákalu automatickým analyzátorem LP-0011K (ASTM D5771; ČSN EN ISO 3015) Paliwa silnikowe Oznaczanie temperatury metnienia analizatorem automatycznym Motorova paliva Stanoveni bodu zakalu automatickym analyzatorem LP-0011K (ASTM D5771; CSN EN ISO 3015)","search_en":"Motor fuels Determination of cloud point by automatic analyzer LP-0011K (ASTM D5771; ČSN EN ISO 3015)","search_zh":"发动机燃料 自动分析仪测定浊点 LP-0011K (ASTM D5771; ČSN EN ISO 3015)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a7eaa786fe8f0959cf1e8d0a","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"27","test_object":"Nafta lotnicza (paliwo lotnicze)","test_object_en":"Aviation fuel","test_object_zh":"航空煤油","test_object_cs":"Letecký petrolej","methodology":"Oznaczanie temperatury krystalizacji","methodology_en":"Determination of crystallization point","methodology_zh":"结晶点测定","methodology_cs":"Stanovení bodu krystalizace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury krystalizacji","reference":"LP-0010K (ASTM D5972)","norm_bases":["LP-0010K","ASTM D5972"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nafta lotnicza (paliwo lotnicze) Oznaczanie temperatury krystalizacji Letecký petrolej Stanovení bodu krystalizace LP-0010K (ASTM D5972) Nafta lotnicza (paliwo lotnicze) Oznaczanie temperatury krystalizacji Letecky petrolej Stanoveni bodu krystalizace LP-0010K (ASTM D5972)","search_en":"Aviation fuel Determination of crystallization point LP-0010K (ASTM D5972)","search_zh":"航空煤油 结晶点测定 LP-0010K (ASTM D5972)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"23587b82c9e367e778dc63fe","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"28","test_object":"Nafta lotnicza (paliwo lotnicze)","test_object_en":"Aviation fuel","test_object_zh":"航空煤油","test_object_cs":"Letecký petrolej","methodology":"Oznaczanie temperatury zapłonu metodą Taga","methodology_en":"Determination of flash point acc. to Tag","methodology_zh":"泰格法闪点测定","methodology_cs":"Stanovení bodu vzplanutí dle Taga","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury zapłonu metodą Taga","reference":"LP 0009K (ASTM D56)","norm_bases":["LP 0009K","ASTM D56"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nafta lotnicza (paliwo lotnicze) Oznaczanie temperatury zapłonu metodą Taga Letecký petrolej Stanovení bodu vzplanutí dle Taga LP 0009K (ASTM D56) Nafta lotnicza (paliwo lotnicze) Oznaczanie temperatury zaplonu metoda Taga Letecky petrolej Stanoveni bodu vzplanuti dle Taga LP 0009K (ASTM D56)","search_en":"Aviation fuel Determination of flash point acc. to Tag LP 0009K (ASTM D56)","search_zh":"航空煤油 泰格法闪点测定 LP 0009K (ASTM D56)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aec8ff2af92b5f393335ac04","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"29","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie liczby cetanowej metodą silnikową","methodology_en":"Determination of cetane number by engine method","methodology_zh":"发动机法十六烷值测定","methodology_cs":"Stanovení cetanového čísla motorovou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby cetanowej metodą silnikową","reference":"LP 0235K (ČSN EN ISO 5165)","norm_bases":["LP 0235K","ČSN EN ISO 5165"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie liczby cetanowej metodą silnikową Motorová paliva Stanovení cetanového čísla motorovou metodou LP 0235K (ČSN EN ISO 5165) Paliwa silnikowe Oznaczanie liczby cetanowej metoda silnikowa Motorova paliva Stanoveni cetanoveho cisla motorovou metodou LP 0235K (CSN EN ISO 5165)","search_en":"Motor fuels Determination of cetane number by engine method LP 0235K (ČSN EN ISO 5165)","search_zh":"发动机燃料 发动机法十六烷值测定 LP 0235K (ČSN EN ISO 5165)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c9aa92ec00375da3088c80c","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"30","test_object":"Paliwa silnikowe","test_object_en":"Motor fuels","test_object_zh":"发动机燃料","test_object_cs":"Motorová paliva","methodology":"Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem","methodology_en":"Determination of derived cetane number (DCN) by analyzer","methodology_zh":"分析仪测定导出十六烷值（DCN）","methodology_cs":"Stanovení odvozeného cetanového čísla (DCN) analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem","reference":"LP-0238K (ASTM D 7668)","norm_bases":["LP-0238K","ASTM D 7668"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Paliwa silnikowe Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem Motorová paliva Stanovení odvozeného cetanového čísla (DCN) analyzátorem LP-0238K (ASTM D 7668) Paliwa silnikowe Oznaczanie pochodnej liczby cetanowej (DCN) analizatorem Motorova paliva Stanoveni odvozeneho cetanoveho cisla (DCN) analyzatorem LP-0238K (ASTM D 7668)","search_en":"Motor fuels Determination of derived cetane number (DCN) by analyzer LP-0238K (ASTM D 7668)","search_zh":"发动机燃料 分析仪测定导出十六烷值（DCN） LP-0238K (ASTM D 7668)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eced5cd69b1000e9f75dd2f0","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"31","test_object":"Gazowe mieszaniny węglowodorów, LPG","test_object_en":"Gaseous hydrocarbon mixtures, LPG","test_object_zh":"气态烃混合物、液化石油气","test_object_cs":"Plynné uhlovodíkové směsi, LPG","methodology":"Oznaczanie węglowodorów C1 – C5 metodą GC/FID","methodology_en":"Determination of hydrocarbons C1 – C5 by GC/FID method","methodology_zh":"GC/FID法测定C1 – C5烃","methodology_cs":"Stanovení uhlovodíků C1 – C5 metodou GC/FID","parameters":[{"name":"Metan","range":""},{"name":"Etan","range":""},{"name":"Etylen","range":""},{"name":"Propan","range":""},{"name":"Propylen","range":""},{"name":"Izobutan","range":""},{"name":"n-Butan","range":""},{"name":"trans-Buten","range":""},{"name":"n-Buten","range":""},{"name":"Izobuten","range":""},{"name":"cis-Buten","range":""},{"name":"Izopentan","range":""},{"name":"n-Pentan","range":""}],"parameters_en":[{"name":"Methane","range":""},{"name":"Ethane","range":""},{"name":"Ethylene","range":""},{"name":"Propane","range":""},{"name":"Propylene","range":""},{"name":"Isobutane","range":""},{"name":"n-Butane","range":""},{"name":"t-Butene","range":""},{"name":"n-Butene","range":""},{"name":"i-Butene","range":""},{"name":"c-Butene","range":""},{"name":"Isopentane","range":""},{"name":"n-Pentane","range":""}],"parameters_zh":[{"name":"甲烷","range":""},{"name":"乙烷","range":""},{"name":"乙烯","range":""},{"name":"丙烷","range":""},{"name":"丙烯","range":""},{"name":"异丁烷","range":""},{"name":"正丁烷","range":""},{"name":"反丁烯","range":""},{"name":"正丁烯","range":""},{"name":"异丁烯","range":""},{"name":"顺丁烯","range":""},{"name":"异戊烷","range":""},{"name":"正戊烷","range":""}],"parameters_cs":[{"name":"metan","range":""},{"name":"etan","range":""},{"name":"etylen","range":""},{"name":"propan","range":""},{"name":"propylen","range":""},{"name":"isobutan","range":""},{"name":"n-butan","range":""},{"name":"t-buten","range":""},{"name":"n-buten","range":""},{"name":"i-buten","range":""},{"name":"c-buten","range":""},{"name":"isopentan","range":""},{"name":"n-pentan","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C1 – C5 metodą GC/FID\nZakres:\nMetan\nEtan\nEtylen\nPropan\nPropylen\nIzobutan\nn-Butan\ntrans-Buten\nn-Buten\nIzobuten\ncis-Buten\nIzopentan\nn-Pentan","reference":"LP 0075K (ČSN EN 27941)","norm_bases":["LP 0075K","ČSN EN 27941"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gazowe mieszaniny węglowodorów, LPG Oznaczanie węglowodorów C1 – C5 metodą GC/FID Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Plynné uhlovodíkové směsi, LPG Stanovení uhlovodíků C1 – C5 metodou GC/FID metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  LP 0075K (ČSN EN 27941) Gazowe mieszaniny weglowodorow, LPG Oznaczanie weglowodorow C1 – C5 metoda GC/FID Metan  Etan  Etylen  Propan  Propylen  Izobutan  n-Butan  trans-Buten  n-Buten  Izobuten  cis-Buten  Izopentan  n-Pentan  Plynne uhlovodikove smesi, LPG Stanoveni uhlovodiku C1 – C5 metodou GC/FID metan  etan  etylen  propan  propylen  isobutan  n-butan  t-buten  n-buten  i-buten  c-buten  isopentan  n-pentan  LP 0075K (CSN EN 27941)","search_en":"Gaseous hydrocarbon mixtures, LPG Determination of hydrocarbons C1 – C5 by GC/FID method Methane  Ethane  Ethylene  Propane  Propylene  Isobutane  n-Butane  t-Butene  n-Butene  i-Butene  c-Butene  Isopentane  n-Pentane  LP 0075K (ČSN EN 27941)","search_zh":"气态烃混合物、液化石油气 GC/FID法测定C1 – C5烃 甲烷  乙烷  乙烯  丙烷  丙烯  异丁烷  正丁烷  反丁烯  正丁烯  异丁烯  顺丁烯  异戊烷  正戊烷  LP 0075K (ČSN EN 27941)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"530452b83346de6bd618485e","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"1","test_object":"Produkty naftowe","test_object_en":"Petroleum products","test_object_zh":"石油产品","test_object_cs":"Ropné produkty","methodology":"Pobieranie próbek produktów naftowych","methodology_en":"Sampling of petroleum products","methodology_zh":"石油产品采样","methodology_cs":"Odběr vzorků ropných produktů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek produktów naftowych","reference":"LP 0251K (ČSN EN ISO 3170)","norm_bases":["LP 0251K","ČSN EN ISO 3170"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Produkty naftowe Pobieranie próbek produktów naftowych Ropné produkty Odběr vzorků ropných produktů LP 0251K (ČSN EN ISO 3170) Produkty naftowe Pobieranie probek produktow naftowych Ropne produkty Odber vzorku ropnych produktu LP 0251K (CSN EN ISO 3170)","search_en":"Petroleum products Sampling of petroleum products LP 0251K (ČSN EN ISO 3170)","search_zh":"石油产品 石油产品采样 LP 0251K (ČSN EN ISO 3170)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6460f55ac06bb937dbe47370","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków","methodology_en":"Sampling of waste water","methodology_zh":"废水采样","methodology_cs":"Odběr vzorků odpadních vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków","reference":"LP 0253K (ČSN ISO 5667-10)","norm_bases":["LP 0253K","ČSN ISO 5667-10"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków Odpadní vody Odběr vzorků odpadních vod LP 0253K (ČSN ISO 5667-10) Scieki Pobieranie probek sciekow Odpadni vody Odber vzorku odpadnich vod LP 0253K (CSN ISO 5667-10)","search_en":"Waste water Sampling of waste water LP 0253K (ČSN ISO 5667-10)","search_zh":"废水 废水采样 LP 0253K (ČSN ISO 5667-10)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c6b03066ab28c997b6bc0f15","lab_id":"69ad52a4de79e566650fd45c","country":"CZ","accr_number":"1515","accr_body":"ČIA","row_label":"3","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek wód powierzchniowych","methodology_en":"Sampling of surface water","methodology_zh":"地表水采样","methodology_cs":"Odběr vzorků povrchových vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych","reference":"LP-0253K, postup B ČSN ISO 5667-4)","norm_bases":["LP-0253K, postup B","ČSN ISO 5667-4"],"lab_section":"Laboratoria Kralupy","lab_section_en":"Kralupy Laboratories","lab_section_zh":"克拉卢比实验室","lab_section_cs":"Laboratoře Kralupy","lab_address":"Wichterleho 809, 278 01 Kralupy nad Vltavou","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych Povrchové vody Odběr vzorků povrchových vod LP-0253K, postup B ČSN ISO 5667-4) Wody powierzchniowe Pobieranie probek wod powierzchniowych Povrchove vody Odber vzorku povrchovych vod LP-0253K, postup B CSN ISO 5667-4)","search_en":"Surface water Sampling of surface water LP-0253K, postup B ČSN ISO 5667-4)","search_zh":"地表水 地表水采样 LP-0253K, postup B ČSN ISO 5667-4)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}