{"lab":{"_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","address":"Tvarožná  312, 664 05 Tvarožná","categories":["environment","construction"],"city":"Tvarožná","imported_at":"2026-03-08T10:42:44.590Z","methods_count":24,"name":"ENVING s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1510_463_2025_CS.pdf","1510_463_2025_EN.pdf"],"scope_summary":"Pomiary hałasu i drgań w środowisku pracy i poza nim, pomiary izolacyjności akustycznej i czasu pogłosu, pomiary pyłu i szkodliwych substancji chemicznych w środowisku pracy, pomiary emisji ze stacjonarnych źródeł zanieczyszczania powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"enving s.r.o. tvarožná  312, 664 05 tvarožná other","status":"active","updated_at":"2026-03-08T14:52:13.147Z","valid_from":"","valid_until":"15-09-2030","website":"www.enving.cz","parsed_at":"2026-09-28T12:00:00.000Z","email_confidence":"high","email_mx":true,"email_source":"https://www.enving.cz/kontakty","map_coord":[49.19177,16.771457],"map_geo":"nominatim-city","certificate_date":"15.09.2025","certificate_no":"463/2025","certificate_replaces":"333/2024 z 10.07.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Pomiary hałasu i drgań w środowisku pracy i poza nim, pomiary izolacyjności akustycznej i czasu pogłosu, pomiary pyłu i szkodliwych substancji chemicznych w środowisku pracy, pomiary emisji ze stacjonarnych źródeł zanieczyszczania powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Measurement of noise and vibration in working and non-working environments; measurement of sound insulation and reverberation time; measurement of dust and chemical pollutants in working environment; detection of emissions from stationary sources of air pollution to the extent as specified in the appendix to this Certificate.","zh":"工作和非工作环境噪声和振动测量，隔声和混响时间测量，工作环境粉尘和化学有害物测量，固定空气污染源排放测量，范围见本证书附件。","cs":"Měření hluku a vibrací v pracovním a mimopracovním prostředí, měření neprůzvučnosti a měření doby dozvuku, měření prachu a chemických škodlivin v pracovním prostředí, měření emisí ze stacionárních zdrojů znečišťování ovzduší, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Pomiarów","lab_division_cs":"Laboratoř měření","lab_division_en":"Measurement Laboratory","lab_division_zh":"测量实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"OP","pl":"Procedura operacyjna","en":"Operating Procedure","zh":"操作程序","cs":"Operační postup"},{"abbr":"NV","pl":"Rozporządzenie rządu w obowiązującym brzmieniu","en":"Government Regulation, as amended","zh":"现行政府条例","cs":"Nařízení vlády v platném znění"},{"abbr":"NDIR","pl":"Niedyspersyjna spektroskopia w podczerwieni","en":"Nondispersive Infrared Spectrometry","zh":"非分散红外光谱法","cs":"Nedisperzní infračervená spektroskopie"},{"abbr":"FID","pl":"Detekcja płomieniowo-jonizacyjna","en":"Flame Ionization Detection","zh":"火焰离子化检测","cs":"Plameno-ionizační detekce"},{"abbr":"Emise","pl":"gaz odlotowy zawierający zanieczyszczenia, odprowadzany w sposób zorganizowany lub uchodzący do atmosfery ze źródeł zanieczyszczania powietrza","en":"Waste gas containing pollutants released in a controlled manner or leaking into atmosphere from stationary sources of pollution","zh":"含污染物的废气，以受控方式排放或从空气污染源逸入大气","cs":"odpadní plyn s obsahem znečišťujících látek, který je odváděn řízeným způsobem nebo uniká do venkovní atmosféry ze zdrojů znečišťování ovzduší"},{"abbr":"US EPA","pl":"Agencja Ochrony Środowiska Stanów Zjednoczonych (United States Environmental Protection Agency)","en":"United States Environmental Protection Agency","zh":"美国环境保护署","cs":"United States Environmental Protection Agency"},{"abbr":"VOC","pl":"Lotne związki organiczne","en":"Volatile Organic Compounds","zh":"挥发性有机化合物","cs":"Těkavé organické látky"},{"abbr":"TOC","pl":"Ogólny węgiel organiczny","en":"Total Organic Carbon","zh":"总有机碳","cs":"Celkový organický uhlík"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"f0f583d572c6de79f3baa9abe8b8b93de670d70502fd45ab7216ef317ffbe833","source_pdf_url":"https://www.cai.cz/OA/pdf/463_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/463_2025_EN.pdf"},"methods":[{"_id":"f2a7dd6cbd79f2a865d0c9aa","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"1","test_object":"Środowisko pracy","test_object_en":"Working environment","test_object_zh":"工作环境","test_object_cs":"Pracovní prostředí","methodology":"Pomiar hałasu","methodology_en":"Measurement of noise","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"ČSN EN ISO 9612; Věstník MZ ČR, 2013, částka 4, část 4","norm_bases":["ČSN EN ISO 9612","Věstník MZ ČR, 2013, částka 4, část 4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pracy Pomiar hałasu Pracovní prostředí Měření hluku ČSN EN ISO 9612; Věstník MZ ČR, 2013, částka 4, část 4 Srodowisko pracy Pomiar halasu Pracovni prostredi Mereni hluku CSN EN ISO 9612; Vestnik MZ CR, 2013, castka 4, cast 4","search_en":"Working environment Measurement of noise ČSN EN ISO 9612; Věstník MZ ČR, 2013, částka 4, část 4","search_zh":"工作环境 噪声测量 ČSN EN ISO 9612; Věstník MZ ČR, 2013, částka 4, část 4","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e9aa367183ea5d2ebf28b749","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"2","test_object":"Środowisko poza miejscem pracy","test_object_en":"Non-working environment","test_object_zh":"非工作环境","test_object_cs":"Mimopracovní prostředí","methodology":"Pomiar hałasu","methodology_en":"Measurement of noise","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, 2023, částka 14","norm_bases":["ČSN ISO 1996-1","ČSN ISO 1996-2","Věstník MZ ČR, 2023, částka 14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko poza miejscem pracy Pomiar hałasu Mimopracovní prostředí Měření hluku ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, 2023, částka 14 Srodowisko poza miejscem pracy Pomiar halasu Mimopracovni prostredi Mereni hluku CSN ISO 1996-1; CSN ISO 1996-2; Vestnik MZ CR, 2023, castka 14","search_en":"Non-working environment Measurement of noise ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, 2023, částka 14","search_zh":"非工作环境 噪声测量 ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, 2023, částka 14","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b1485dd3f5e9b2917ddd07cc","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"3","test_object":"Środowisko pracy i poza miejscem pracy","test_object_en":"Working and non-working environment","test_object_zh":"工作和非工作环境","test_object_cs":"Pracovní a mimopracovní prostředí","methodology":"Pomiar drgań","methodology_en":"Measurement of vibrations","methodology_zh":"振动测量","methodology_cs":"Měření vibrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar drgań","reference":"ČSN ISO 2631-1; ČSN ISO 2631-2; ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; Věstník MZ ČR, 2013, částka 4, část 4","norm_bases":["ČSN ISO 2631-1","ČSN ISO 2631-2","ČSN EN ISO 5349-1","ČSN EN ISO 5349-2","Věstník MZ ČR, 2013, částka 4, část 4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pracy i poza miejscem pracy Pomiar drgań Pracovní a mimopracovní prostředí Měření vibrací ČSN ISO 2631-1; ČSN ISO 2631-2; ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; Věstník MZ ČR, 2013, částka 4, část 4 Srodowisko pracy i poza miejscem pracy Pomiar drgan Pracovni a mimopracovni prostredi Mereni vibraci CSN ISO 2631-1; CSN ISO 2631-2; CSN EN ISO 5349-1; CSN EN ISO 5349-2; Vestnik MZ CR, 2013, castka 4, cast 4","search_en":"Working and non-working environment Measurement of vibrations ČSN ISO 2631-1; ČSN ISO 2631-2; ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; Věstník MZ ČR, 2013, částka 4, část 4","search_zh":"工作和非工作环境 振动测量 ČSN ISO 2631-1; ČSN ISO 2631-2; ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; Věstník MZ ČR, 2013, částka 4, část 4","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c7bf95396f1d498a6d0e2b87","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"4","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie prędkości przepływu i strumienia objętości w przewodach","methodology_en":"Determination of velocity and volume flowrate of gas streams in ducts","methodology_zh":"管道内气流速度和体积流量测定","methodology_cs":"Stanovení rychlosti proudění a objemového toku v potrubí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prędkości przepływu i strumienia objętości w przewodach","reference":"OP 4 (ČSN ISO 10780)","norm_bases":["OP 4","ČSN ISO 10780"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Oznaczanie prędkości przepływu i strumienia objętości w przewodach Emise Stanovení rychlosti proudění a objemového toku v potrubí OP 4 (ČSN ISO 10780) Emisje Oznaczanie predkosci przeplywu i strumienia objetosci w przewodach Emise Stanoveni rychlosti proudeni a objemoveho toku v potrubi OP 4 (CSN ISO 10780)","search_en":"Emissions Determination of velocity and volume flowrate of gas streams in ducts OP 4 (ČSN ISO 10780)","search_zh":"排放 管道内气流速度和体积流量测定 OP 4 (ČSN ISO 10780)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"baeecb6fcc93411cd03046ef","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"5","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie wilgotności gazu (metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnościowy)","methodology_en":"Determination of the moisture content in gas (condensation method, adsorption method, capacitance detector)","methodology_zh":"气体湿度测定（冷凝法、吸附法、电容传感器）","methodology_cs":"Stanovení vlhkosti plynu (metoda kondenzační, metoda adsorpční, kapacitní čidlo)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności gazu (metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnościowy)","reference":"OP 5 (ČSN EN 14790)","norm_bases":["OP 5","ČSN EN 14790"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Oznaczanie wilgotności gazu (metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnościowy) Emise Stanovení vlhkosti plynu (metoda kondenzační, metoda adsorpční, kapacitní čidlo) OP 5 (ČSN EN 14790) Emisje Oznaczanie wilgotnosci gazu (metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnosciowy) Emise Stanoveni vlhkosti plynu (metoda kondenzacni, metoda adsorpcni, kapacitni cidlo) OP 5 (CSN EN 14790)","search_en":"Emissions Determination of the moisture content in gas (condensation method, adsorption method, capacitance detector) OP 5 (ČSN EN 14790)","search_zh":"排放 气体湿度测定（冷凝法、吸附法、电容传感器） OP 5 (ČSN EN 14790)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b49d70d5fdb651c67fc0948f","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"6","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia objętościowego tlenu (O2) analizatorem automatycznym (metoda paramagnetyczna)","methodology_en":"Determination of concentration of oxygen (O2) by automatic analyzer (paramagnetic method)","methodology_zh":"自动分析仪测定氧气（O2）体积浓度（顺磁法）","methodology_cs":"Stanovení objemové koncentrace kyslíku (O2) automatizovaným analyzátorem (paramagnetická metoda)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia objętościowego tlenu (O2) analizatorem automatycznym (metoda paramagnetyczna)","reference":"OP 6 (ČSN EN 14789; ČSN ISO 10396:1998)","norm_bases":["OP 6","ČSN EN 14789","ČSN ISO 10396:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Oznaczanie stężenia objętościowego tlenu (O2) analizatorem automatycznym (metoda paramagnetyczna) Emise Stanovení objemové koncentrace kyslíku (O2) automatizovaným analyzátorem (paramagnetická metoda) OP 6 (ČSN EN 14789; ČSN ISO 10396:1998) Emisje Oznaczanie stezenia objetosciowego tlenu (O2) analizatorem automatycznym (metoda paramagnetyczna) Emise Stanoveni objemove koncentrace kysliku (O2) automatizovanym analyzatorem (paramagneticka metoda) OP 6 (CSN EN 14789; CSN ISO 10396:1998)","search_en":"Emissions Determination of concentration of oxygen (O2) by automatic analyzer (paramagnetic method) OP 6 (ČSN EN 14789; ČSN ISO 10396:1998)","search_zh":"排放 自动分析仪测定氧气（O2）体积浓度（顺磁法） OP 6 (ČSN EN 14789; ČSN ISO 10396:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9fc21bfa5871c6b6da2792c3","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"7","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego zanieczyszczeń gazowych (SO2, NOX, CO) analizatorami automatycznymi (metoda NDIR)","methodology_en":"Determination of mass concentration of gaseous pollutants (SO2, NOX, CO) by automated analyzers (NDIR method)","methodology_zh":"自动分析仪测定气态污染物（SO2、NOX、CO）质量浓度（NDIR法）","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOX, CO) automatizovanými analyzátory (metoda NDIR)","parameters":[{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki azotu (NOX)","range":""},{"name":"Tlenek węgla (CO)","range":""}],"parameters_en":[{"name":"SO2","range":""},{"name":"NOX","range":""},{"name":"CO","range":""}],"parameters_zh":[{"name":"二氧化硫（SO2）","range":""},{"name":"氮氧化物（NOX）","range":""},{"name":"一氧化碳（CO）","range":""}],"parameters_cs":[{"name":"SO2","range":""},{"name":"NOX","range":""},{"name":"CO","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego zanieczyszczeń gazowych (SO2, NOX, CO) analizatorami automatycznymi (metoda NDIR)\nZakres:\nDitlenek siarki (SO2)\nTlenki azotu (NOX)\nTlenek węgla (CO)","reference":"OP 7 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN ISO 10396:1998)","norm_bases":["OP 7","ČSN ISO 7935","ČSN ISO 10849","ČSN EN 15058","ČSN ISO 10396:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Oznaczanie stężenia masowego zanieczyszczeń gazowych (SO2, NOX, CO) analizatorami automatycznymi (metoda NDIR) Ditlenek siarki (SO2)  Tlenki azotu (NOX)  Tlenek węgla (CO)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOX, CO) automatizovanými analyzátory (metoda NDIR) SO2  NOX  CO  OP 7 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN ISO 10396:1998) Emisje Oznaczanie stezenia masowego zanieczyszczen gazowych (SO2, NOX, CO) analizatorami automatycznymi (metoda NDIR) Ditlenek siarki (SO2)  Tlenki azotu (NOX)  Tlenek wegla (CO)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek (SO2, NOX, CO) automatizovanymi analyzatory (metoda NDIR) SO2  NOX  CO  OP 7 (CSN ISO 7935; CSN ISO 10849; CSN EN 15058; CSN ISO 10396:1998)","search_en":"Emissions Determination of mass concentration of gaseous pollutants (SO2, NOX, CO) by automated analyzers (NDIR method) SO2  NOX  CO  OP 7 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN ISO 10396:1998)","search_zh":"排放 自动分析仪测定气态污染物（SO2、NOX、CO）质量浓度（NDIR法） 二氧化硫（SO2）  氮氧化物（NOX）  一氧化碳（CO）  OP 7 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN ISO 10396:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67ff2a191a3d0678d770c4fe","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"8","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie łącznego stężenia masowego substancji organicznych wyrażonych jako ogólny węgiel organiczny (TOC) analizatorami automatycznymi (FID)","methodology_en":"Determination of total mass concentration of organic compounds expressed as total organic carbon (TOC) by automatic analyzers (FID)","methodology_zh":"自动分析仪（FID）测定以总有机碳（TOC）表示的有机物总质量浓度","methodology_cs":"Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory (FID)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie łącznego stężenia masowego substancji organicznych wyrażonych jako ogólny węgiel organiczny (TOC) analizatorami automatycznymi (FID)","reference":"OP 8 (ČSN EN 12619)","norm_bases":["OP 8","ČSN EN 12619"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Oznaczanie łącznego stężenia masowego substancji organicznych wyrażonych jako ogólny węgiel organiczny (TOC) analizatorami automatycznymi (FID) Emise Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory (FID) OP 8 (ČSN EN 12619) Emisje Oznaczanie lacznego stezenia masowego substancji organicznych wyrazonych jako ogolny wegiel organiczny (TOC) analizatorami automatycznymi (FID) Emise Stanoveni uhrnne hmotnostni koncentrace organickych latek vyjadrenych jako celkovy organicky uhlik (TOC) automatizovanymi analyzatory (FID) OP 8 (CSN EN 12619)","search_en":"Emissions Determination of total mass concentration of organic compounds expressed as total organic carbon (TOC) by automatic analyzers (FID) OP 8 (ČSN EN 12619)","search_zh":"排放 自动分析仪（FID）测定以总有机碳（TOC）表示的有机物总质量浓度 OP 8 (ČSN EN 12619)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"043f7cbf1ca0c366af37c48d","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"9","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą wagową","methodology_en":"Determination of mass concentration of solid pollutants by gravimetry","methodology_zh":"重量法固体污染物质量浓度测定","methodology_cs":"Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą wagową","reference":"OP 9 – část A (ČSN EN 13284-1; ČSN ISO 9096:1998)","norm_bases":["OP 9 – část A","ČSN EN 13284-1","ČSN ISO 9096:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą wagową Emise Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetricky OP 9 – část A (ČSN EN 13284-1; ČSN ISO 9096:1998) Emisje Oznaczanie stezenia masowego pylowych substancji zanieczyszczajacych metoda wagowa Emise Stanoveni hmotnostni koncentrace tuhych znecistujicich latek gravimetricky OP 9 – cast A (CSN EN 13284-1; CSN ISO 9096:1998)","search_en":"Emissions Determination of mass concentration of solid pollutants by gravimetry OP 9 – část A (ČSN EN 13284-1; ČSN ISO 9096:1998)","search_zh":"排放 重量法固体污染物质量浓度测定 OP 9 – část A (ČSN EN 13284-1; ČSN ISO 9096:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b96ee131482d9ff8b0a65dda","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"10","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of metals by calculation from measured values","methodology_zh":"根据测量值计算金属质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace kovů výpočtem z naměřených hodnot","parameters":[{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Wanad (V)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Vanadium (V)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""},{"name":"铬（Cr）","range":""},{"name":"钴（Co）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"铊（Tl）","range":""},{"name":"锌（Zn）","range":""},{"name":"钒（V）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Cd","range":""},{"name":"Cr","range":""},{"name":"Co","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Tl","range":""},{"name":"Zn","range":""},{"name":"V","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych\nZakres:\nArsen (As)\nKadm (Cd)\nChrom (Cr)\nKobalt (Co)\nMiedź (Cu)\nMangan (Mn)\nNikiel (Ni)\nOłów (Pb)\nAntymon (Sb)\nTal (Tl)\nCynk (Zn)\nWanad (V)","reference":"OP 10 - část A (ČSN EN 14385; US EPA method 29)","norm_bases":["OP 10 - část A","ČSN EN 14385","US EPA method 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"the laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisje Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych Arsen (As)  Kadm (Cd)  Chrom (Cr)  Kobalt (Co)  Miedź (Cu)  Mangan (Mn)  Nikiel (Ni)  Ołów (Pb)  Antymon (Sb)  Tal (Tl)  Cynk (Zn)  Wanad (V)  Emise Stanovení hmotnostní koncentrace kovů výpočtem z naměřených hodnot As  Cd  Cr  Co  Cu  Mn  Ni  Pb  Sb  Tl  Zn  V  OP 10 - část A (ČSN EN 14385; US EPA method 29) Emisje Oznaczanie stezenia masowego metali obliczeniowo z wartosci zmierzonych Arsen (As)  Kadm (Cd)  Chrom (Cr)  Kobalt (Co)  Miedz (Cu)  Mangan (Mn)  Nikiel (Ni)  Olow (Pb)  Antymon (Sb)  Tal (Tl)  Cynk (Zn)  Wanad (V)  Emise Stanoveni hmotnostni koncentrace kovu vypoctem z namerenych hodnot As  Cd  Cr  Co  Cu  Mn  Ni  Pb  Sb  Tl  Zn  V  OP 10 - cast A (CSN EN 14385; US EPA method 29)","search_en":"Emissions Determination of mass concentration of metals by calculation from measured values Arsenic (As)  Cadmium (Cd)  Chromium (Cr)  Cobalt (Co)  Copper (Cu)  Manganese (Mn)  Nickel (Ni)  Lead (Pb)  Antimony (Sb)  Thallium (Tl)  Zinc (Zn)  Vanadium (V)  OP 10 - část A (ČSN EN 14385; US EPA method 29)","search_zh":"排放 根据测量值计算金属质量浓度 砷（As）  镉（Cd）  铬（Cr）  钴（Co）  铜（Cu）  锰（Mn）  镍（Ni）  铅（Pb）  锑（Sb）  铊（Tl）  锌（Zn）  钒（V）  OP 10 - část A (ČSN EN 14385; US EPA method 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6a792ced271719329adcf27c","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"11","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego lotnych związków organicznych (VOC) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values","methodology_zh":"根据测量值计算挥发性有机化合物（VOC）质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace těkavých organických látek (VOC) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego lotnych związków organicznych (VOC) obliczeniowo z wartości zmierzonych","reference":"OP 11 – část A (ČSN P CEN/TS 13649)","norm_bases":["OP 11 – část A","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"the laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisje Oznaczanie stężenia masowego lotnych związków organicznych (VOC) obliczeniowo z wartości zmierzonych Emise Stanovení hmotnostní koncentrace těkavých organických látek (VOC) výpočtem z naměřených hodnot OP 11 – část A (ČSN P CEN/TS 13649) Emisje Oznaczanie stezenia masowego lotnych zwiazkow organicznych (VOC) obliczeniowo z wartosci zmierzonych Emise Stanoveni hmotnostni koncentrace tekavych organickych latek (VOC) vypoctem z namerenych hodnot OP 11 – cast A (CSN P CEN/TS 13649)","search_en":"Emissions Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values OP 11 – část A (ČSN P CEN/TS 13649)","search_zh":"排放 根据测量值计算挥发性有机化合物（VOC）质量浓度 OP 11 – část A (ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04570858f0ebccd6937cb54c","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"12","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego chlorowodoru i chlorków obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of hydrogen chloride and chlorides by calculation from measured values","methodology_zh":"根据测量值计算氯化氢和氯化物质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace chlorovodíku a chloridů výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego chlorowodoru i chlorków obliczeniowo z wartości zmierzonych","reference":"OP 12 – část A (ČSN EN 1911)","norm_bases":["OP 12 – část A","ČSN EN 1911"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"the laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisje Oznaczanie stężenia masowego chlorowodoru i chlorków obliczeniowo z wartości zmierzonych Emise Stanovení hmotnostní koncentrace chlorovodíku a chloridů výpočtem z naměřených hodnot OP 12 – část A (ČSN EN 1911) Emisje Oznaczanie stezenia masowego chlorowodoru i chlorkow obliczeniowo z wartosci zmierzonych Emise Stanoveni hmotnostni koncentrace chlorovodiku a chloridu vypoctem z namerenych hodnot OP 12 – cast A (CSN EN 1911)","search_en":"Emissions Determination of mass concentration of hydrogen chloride and chlorides by calculation from measured values OP 12 – část A (ČSN EN 1911)","search_zh":"排放 根据测量值计算氯化氢和氯化物质量浓度 OP 12 – část A (ČSN EN 1911)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f7b8e2f0754dbadccfdb3f82","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"13","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Working air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Oznaczanie gazów i par metodą detekcyjną","methodology_en":"Determination of gases and vapours by detection method","methodology_zh":"检测管法气体和蒸气测定","methodology_cs":"Stanovení plynů a par detekční metodou","parameters":[{"name":"Tlenki azotu (NOX)","range":""},{"name":"Tlenek węgla (CO)","range":""},{"name":"Ditlenek węgla (CO2)","range":""},{"name":"Ozon (O3)","range":""},{"name":"Amoniak (NH3)","range":""},{"name":"Ditlenek siarki (SO2)","range":""}],"parameters_en":[{"name":"NOX","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"O3","range":""},{"name":"NH3","range":""},{"name":"SO2","range":""}],"parameters_zh":[{"name":"氮氧化物（NOX）","range":""},{"name":"一氧化碳（CO）","range":""},{"name":"二氧化碳（CO2）","range":""},{"name":"臭氧（O3）","range":""},{"name":"氨（NH3）","range":""},{"name":"二氧化硫（SO2）","range":""}],"parameters_cs":[{"name":"NOX","range":""},{"name":"CO","range":""},{"name":"CO2","range":""},{"name":"O3","range":""},{"name":"NH3","range":""},{"name":"SO2","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gazów i par metodą detekcyjną\nZakres:\nTlenki azotu (NOX)\nTlenek węgla (CO)\nDitlenek węgla (CO2)\nOzon (O3)\nAmoniak (NH3)\nDitlenek siarki (SO2)","reference":"OP 13 (NV č. 361/2007 Sb.; manuál firmy Kavalier)","norm_bases":["OP 13","NV č. 361/2007 Sb.","manuál firmy Kavalier"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie gazów i par metodą detekcyjną Tlenki azotu (NOX)  Tlenek węgla (CO)  Ditlenek węgla (CO2)  Ozon (O3)  Amoniak (NH3)  Ditlenek siarki (SO2)  Pracovní ovzduší Stanovení plynů a par detekční metodou NOX  CO  CO2  O3  NH3  SO2  OP 13 (NV č. 361/2007 Sb.; manuál firmy Kavalier) Powietrze na stanowiskach pracy Oznaczanie gazow i par metoda detekcyjna Tlenki azotu (NOX)  Tlenek wegla (CO)  Ditlenek wegla (CO2)  Ozon (O3)  Amoniak (NH3)  Ditlenek siarki (SO2)  Pracovni ovzdusi Stanoveni plynu a par detekcni metodou NOX  CO  CO2  O3  NH3  SO2  OP 13 (NV c. 361/2007 Sb.; manual firmy Kavalier)","search_en":"Working air Determination of gases and vapours by detection method NOX  CO  CO2  O3  NH3  SO2  OP 13 (NV č. 361/2007 Sb.; manuál firmy Kavalier)","search_zh":"工作场所空气 检测管法气体和蒸气测定 氮氧化物（NOX）  一氧化碳（CO）  二氧化碳（CO2）  臭氧（O3）  氨（NH3）  二氧化硫（SO2）  OP 13 (NV č. 361/2007 Sb.; manuál firmy Kavalier)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a4f03459a1ba59e6f5214fa","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"14","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Working air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Oznaczanie stężenia pyłu metodą wagową","methodology_en":"Determination of concentration of dust by gravimetry","methodology_zh":"重量法粉尘浓度测定","methodology_cs":"Stanovení koncentrace prachu gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia pyłu metodą wagową","reference":"OP 14 – část A (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC)","norm_bases":["OP 14 – část A","NV č. 361/2007 Sb.","ČSN EN 481","ČSN EN 689+AC"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie stężenia pyłu metodą wagową Pracovní ovzduší Stanovení koncentrace prachu gravimetricky OP 14 – část A (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC) Powietrze na stanowiskach pracy Oznaczanie stezenia pylu metoda wagowa Pracovni ovzdusi Stanoveni koncentrace prachu gravimetricky OP 14 – cast A (NV c. 361/2007 Sb.; CSN EN 481; CSN EN 689+AC)","search_en":"Working air Determination of concentration of dust by gravimetry OP 14 – část A (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC)","search_zh":"工作场所空气 重量法粉尘浓度测定 OP 14 – část A (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8513729eaba67b292200544c","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"15","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Working air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Oznaczanie stężenia masowego substancji organicznych i nieorganicznych obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of organic and inorganic compounds by calculation from measured values","methodology_zh":"根据测量值计算有机和无机物质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace organických a anorganických látek výpočtem z naměřených hodnot","parameters":[{"name":"Kwasy mineralne","range":""},{"name":"Cyjanki","range":""},{"name":"Amoniak","range":""},{"name":"Fosforany","range":""},{"name":"Chrom ogólny (Cr)","range":""},{"name":"Chrom sześciowartościowy (Cr VI)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Glin (Al)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Srebro (Ag)","range":""},{"name":"Selen (Se)","range":""},{"name":"Platyna (Pt)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Tytan (Ti)","range":""},{"name":"Węglowodory alifatyczne","range":""},{"name":"Węglowodory aromatyczne","range":""},{"name":"Węglowodory halogenowe","range":""},{"name":"Izocyjaniany","range":""}],"parameters_en":[{"name":"Mineral acids","range":""},{"name":"Cyanides","range":""},{"name":"Ammonia","range":""},{"name":"Phosphates","range":""},{"name":"Chromium total (Cr total)","range":""},{"name":"Chromium VI (Cr VI)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Silver (Ag)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Platinum (Pt)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Titanium (Ti)","range":""},{"name":"Aliphatic hydrocarbons","range":""},{"name":"Aromatic hydrocarbons","range":""},{"name":"Halogen hydrocarbons","range":""},{"name":"Isocyanates","range":""}],"parameters_zh":[{"name":"无机酸","range":""},{"name":"氰化物","range":""},{"name":"氨","range":""},{"name":"磷酸盐","range":""},{"name":"总铬（Cr）","range":""},{"name":"六价铬（Cr VI）","range":""},{"name":"镍（Ni）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"锌（Zn）","range":""},{"name":"铅（Pb）","range":""},{"name":"镉（Cd）","range":""},{"name":"锡（Sn）","range":""},{"name":"铝（Al）","range":""},{"name":"钼（Mo）","range":""},{"name":"银（Ag）","range":""},{"name":"硒（Se）","range":""},{"name":"铂（Pt）","range":""},{"name":"钴（Co）","range":""},{"name":"钛（Ti）","range":""},{"name":"脂肪烃","range":""},{"name":"芳香烃","range":""},{"name":"卤代烃","range":""},{"name":"异氰酸酯","range":""}],"parameters_cs":[{"name":"minerální kyseliny","range":""},{"name":"kyanidy","range":""},{"name":"amoniak","range":""},{"name":"fosforečnany","range":""},{"name":"Cr celk.","range":""},{"name":"Cr VI","range":""},{"name":"Ni","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Zn","range":""},{"name":"Pb","range":""},{"name":"Cd","range":""},{"name":"Sn","range":""},{"name":"Al","range":""},{"name":"Mo","range":""},{"name":"Ag","range":""},{"name":"Se","range":""},{"name":"Pt","range":""},{"name":"Co","range":""},{"name":"Ti","range":""},{"name":"alifatické uhlovodíky","range":""},{"name":"aromatické uhlovodíky","range":""},{"name":"halogenové uhlovodíky","range":""},{"name":"izokyanáty","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego substancji organicznych i nieorganicznych obliczeniowo z wartości zmierzonych\nZakres:\nKwasy mineralne\nCyjanki\nAmoniak\nFosforany\nChrom ogólny (Cr)\nChrom sześciowartościowy (Cr VI)\nNikiel (Ni)\nMiedź (Cu)\nMangan (Mn)\nCynk (Zn)\nOłów (Pb)\nKadm (Cd)\nCyna (Sn)\nGlin (Al)\nMolibden (Mo)\nSrebro (Ag)\nSelen (Se)\nPlatyna (Pt)\nKobalt (Co)\nTytan (Ti)\nWęglowodory alifatyczne\nWęglowodory aromatyczne\nWęglowodory halogenowe\nIzocyjaniany","reference":"OP 15 – část A (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649)","norm_bases":["OP 15 – část A","NV č. 361/2007 Sb.","ČSN EN 482","ČSN EN 689+AC","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"the laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Powietrze na stanowiskach pracy Oznaczanie stężenia masowego substancji organicznych i nieorganicznych obliczeniowo z wartości zmierzonych Kwasy mineralne  Cyjanki  Amoniak  Fosforany  Chrom ogólny (Cr)  Chrom sześciowartościowy (Cr VI)  Nikiel (Ni)  Miedź (Cu)  Mangan (Mn)  Cynk (Zn)  Ołów (Pb)  Kadm (Cd)  Cyna (Sn)  Glin (Al)  Molibden (Mo)  Srebro (Ag)  Selen (Se)  Platyna (Pt)  Kobalt (Co)  Tytan (Ti)  Węglowodory alifatyczne  Węglowodory aromatyczne  Węglowodory halogenowe  Izocyjaniany  Pracovní ovzduší Stanovení hmotnostní koncentrace organických a anorganických látek výpočtem z naměřených hodnot minerální kyseliny  kyanidy  amoniak  fosforečnany  Cr celk.  Cr VI  Ni  Cu  Mn  Zn  Pb  Cd  Sn  Al  Mo  Ag  Se  Pt  Co  Ti  alifatické uhlovodíky  aromatické uhlovodíky  halogenové uhlovodíky  izokyanáty  OP 15 – část A (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649) Powietrze na stanowiskach pracy Oznaczanie stezenia masowego substancji organicznych i nieorganicznych obliczeniowo z wartosci zmierzonych Kwasy mineralne  Cyjanki  Amoniak  Fosforany  Chrom ogolny (Cr)  Chrom szesciowartosciowy (Cr VI)  Nikiel (Ni)  Miedz (Cu)  Mangan (Mn)  Cynk (Zn)  Olow (Pb)  Kadm (Cd)  Cyna (Sn)  Glin (Al)  Molibden (Mo)  Srebro (Ag)  Selen (Se)  Platyna (Pt)  Kobalt (Co)  Tytan (Ti)  Weglowodory alifatyczne  Weglowodory aromatyczne  Weglowodory halogenowe  Izocyjaniany  Pracovni ovzdusi Stanoveni hmotnostni koncentrace organickych a anorganickych latek vypoctem z namerenych hodnot mineralni kyseliny  kyanidy  amoniak  fosforecnany  Cr celk.  Cr VI  Ni  Cu  Mn  Zn  Pb  Cd  Sn  Al  Mo  Ag  Se  Pt  Co  Ti  alifaticke uhlovodiky  aromaticke uhlovodiky  halogenove uhlovodiky  izokyanaty  OP 15 – cast A (NV c. 361/2007 Sb.; CSN EN 482; CSN EN 689+AC; CSN P CEN/TS 13649)","search_en":"Working air Determination of mass concentration of organic and inorganic compounds by calculation from measured values Mineral acids  Cyanides  Ammonia  Phosphates  Chromium total (Cr total)  Chromium VI (Cr VI)  Nickel (Ni)  Copper (Cu)  Manganese (Mn)  Zinc (Zn)  Lead (Pb)  Cadmium (Cd)  Tin (Sn)  Aluminium (Al)  Molybdenum (Mo)  Silver (Ag)  Selenium (Se)  Platinum (Pt)  Cobalt (Co)  Titanium (Ti)  Aliphatic hydrocarbons  Aromatic hydrocarbons  Halogen hydrocarbons  Isocyanates  OP 15 – část A (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649)","search_zh":"工作场所空气 根据测量值计算有机和无机物质量浓度 无机酸  氰化物  氨  磷酸盐  总铬（Cr）  六价铬（Cr VI）  镍（Ni）  铜（Cu）  锰（Mn）  锌（Zn）  铅（Pb）  镉（Cd）  锡（Sn）  铝（Al）  钼（Mo）  银（Ag）  硒（Se）  铂（Pt）  钴（Co）  钛（Ti）  脂肪烃  芳香烃  卤代烃  异氰酸酯  OP 15 – část A (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2ca7e9949b5a465343c8938","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"16","test_object":"Konstrukcje budowlane","test_object_en":"Building structures","test_object_zh":"建筑结构","test_object_cs":"Stavební konstrukce","methodology":"Pomiar izolacyjności od dźwięków powietrznych","methodology_en":"Measurement of airborne sound insulation","methodology_zh":"空气声隔声测量","methodology_cs":"Měření vzduchové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności od dźwięków powietrznych","reference":"ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1","norm_bases":["ČSN EN ISO 16283-1","ČSN EN ISO 16283-3","ČSN EN ISO 717-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje budowlane Pomiar izolacyjności od dźwięków powietrznych Stavební konstrukce Měření vzduchové neprůzvučnosti ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1 Konstrukcje budowlane Pomiar izolacyjnosci od dzwiekow powietrznych Stavebni konstrukce Mereni vzduchove nepruzvucnosti CSN EN ISO 16283-1; CSN EN ISO 16283-3; CSN EN ISO 717-1","search_en":"Building structures Measurement of airborne sound insulation ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1","search_zh":"建筑结构 空气声隔声测量 ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b7fffb56672c77ea6e4d04ff","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"17","test_object":"Konstrukcje budowlane","test_object_en":"Building structures","test_object_zh":"建筑结构","test_object_cs":"Stavební konstrukce","methodology":"Pomiar izolacyjności od dźwięków uderzeniowych","methodology_en":"Measurement of impact sound insulation","methodology_zh":"撞击声隔声测量","methodology_cs":"Měření kročejové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności od dźwięków uderzeniowych","reference":"ČSN EN ISO 16283-2; ČSN EN ISO 717-2","norm_bases":["ČSN EN ISO 16283-2","ČSN EN ISO 717-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje budowlane Pomiar izolacyjności od dźwięków uderzeniowych Stavební konstrukce Měření kročejové neprůzvučnosti ČSN EN ISO 16283-2; ČSN EN ISO 717-2 Konstrukcje budowlane Pomiar izolacyjnosci od dzwiekow uderzeniowych Stavebni konstrukce Mereni krocejove nepruzvucnosti CSN EN ISO 16283-2; CSN EN ISO 717-2","search_en":"Building structures Measurement of impact sound insulation ČSN EN ISO 16283-2; ČSN EN ISO 717-2","search_zh":"建筑结构 撞击声隔声测量 ČSN EN ISO 16283-2; ČSN EN ISO 717-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1537fa65673337dca7ed0f60","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"18","test_object":"Pomieszczenia wewnętrzne","test_object_en":"Indoor spaces","test_object_zh":"室内空间","test_object_cs":"Vnitřní prostory","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN EN ISO 3382-1; ČSN EN ISO 3382-2","norm_bases":["ČSN EN ISO 3382-1","ČSN EN ISO 3382-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia wewnętrzne Pomiar czasu pogłosu Vnitřní prostory Měření doby dozvuku ČSN EN ISO 3382-1; ČSN EN ISO 3382-2 Pomieszczenia wewnetrzne Pomiar czasu poglosu Vnitrni prostory Mereni doby dozvuku CSN EN ISO 3382-1; CSN EN ISO 3382-2","search_en":"Indoor spaces Measurement of reverberation time ČSN EN ISO 3382-1; ČSN EN ISO 3382-2","search_zh":"室内空间 混响时间测量 ČSN EN ISO 3382-1; ČSN EN ISO 3382-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd9c1b45f4f20c2c6584fb7b","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"1","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek pyłowych substancji zanieczyszczających (pobór izokinetyczny z ręczną regulacją izokinetyki)","methodology_en":"Sampling of solid pollutants (isokinetic sampling with manual isokinetic control)","methodology_zh":"固体污染物采样（手动控制等速采样）","methodology_cs":"Odběr vzorku tuhých znečišťujících látek (izokinetický odběr s manuálním řízením izokinetiky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek pyłowych substancji zanieczyszczających (pobór izokinetyczny z ręczną regulacją izokinetyki)","reference":"OP 9 – část B (ČSN EN 13284-1; ČSN ISO 9096:1998)","norm_bases":["OP 9 – část B","ČSN EN 13284-1","ČSN ISO 9096:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Pobieranie próbek pyłowych substancji zanieczyszczających (pobór izokinetyczny z ręczną regulacją izokinetyki) Emise Odběr vzorku tuhých znečišťujících látek (izokinetický odběr s manuálním řízením izokinetiky) OP 9 – část B (ČSN EN 13284-1; ČSN ISO 9096:1998) Emisje Pobieranie probek pylowych substancji zanieczyszczajacych (pobor izokinetyczny z reczna regulacja izokinetyki) Emise Odber vzorku tuhych znecistujicich latek (izokineticky odber s manualnim rizenim izokinetiky) OP 9 – cast B (CSN EN 13284-1; CSN ISO 9096:1998)","search_en":"Emissions Sampling of solid pollutants (isokinetic sampling with manual isokinetic control) OP 9 – část B (ČSN EN 13284-1; ČSN ISO 9096:1998)","search_zh":"排放 固体污染物采样（手动控制等速采样） OP 9 – část B (ČSN EN 13284-1; ČSN ISO 9096:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a9cdb7e936ad491e978aff5","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"2","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Izokinetyczne pobieranie próbek do oznaczania metali metodą filtracyjno-absorpcyjną (ręczna regulacja izokinetyki)","methodology_en":"Isokinetic sampling for the determination of metals by filtration-absorption method (manual isokinetic sampling)","methodology_zh":"过滤-吸收法测定金属的等速采样（手动控制等速）","methodology_cs":"Izokinetický odběr vzorku pro stanovení kovů metodou filtračně absorpční (manuální řízení izokinetiky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izokinetyczne pobieranie próbek do oznaczania metali metodą filtracyjno-absorpcyjną (ręczna regulacja izokinetyki)","reference":"OP 10 – část B (ČSN EN 14385; US EPA method 29)","norm_bases":["OP 10 – část B","ČSN EN 14385","US EPA method 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Izokinetyczne pobieranie próbek do oznaczania metali metodą filtracyjno-absorpcyjną (ręczna regulacja izokinetyki) Emise Izokinetický odběr vzorku pro stanovení kovů metodou filtračně absorpční (manuální řízení izokinetiky) OP 10 – část B (ČSN EN 14385; US EPA method 29) Emisje Izokinetyczne pobieranie probek do oznaczania metali metoda filtracyjno-absorpcyjna (reczna regulacja izokinetyki) Emise Izokineticky odber vzorku pro stanoveni kovu metodou filtracne absorpcni (manualni rizeni izokinetiky) OP 10 – cast B (CSN EN 14385; US EPA method 29)","search_en":"Emissions Isokinetic sampling for the determination of metals by filtration-absorption method (manual isokinetic sampling) OP 10 – část B (ČSN EN 14385; US EPA method 29)","search_zh":"排放 过滤-吸收法测定金属的等速采样（手动控制等速） OP 10 – část B (ČSN EN 14385; US EPA method 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"837fd905a7983aab2fbdb9b0","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"3","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek lotnych związków organicznych (VOC) przez wychwyt na sorbencie stałym","methodology_en":"Sampling of volatile organic compounds (VOCs) by capture on a solid sorbent","methodology_zh":"固体吸附剂捕集法挥发性有机化合物（VOC）采样","methodology_cs":"Odběr vzorku těkavých organických látek (VOC) záchytem na pevný sorbent","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek lotnych związków organicznych (VOC) przez wychwyt na sorbencie stałym","reference":"OP 11 – část B (ČSN P CEN/TS 13649)","norm_bases":["OP 11 – část B","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Pobieranie próbek lotnych związków organicznych (VOC) przez wychwyt na sorbencie stałym Emise Odběr vzorku těkavých organických látek (VOC) záchytem na pevný sorbent OP 11 – část B (ČSN P CEN/TS 13649) Emisje Pobieranie probek lotnych zwiazkow organicznych (VOC) przez wychwyt na sorbencie stalym Emise Odber vzorku tekavych organickych latek (VOC) zachytem na pevny sorbent OP 11 – cast B (CSN P CEN/TS 13649)","search_en":"Emissions Sampling of volatile organic compounds (VOCs) by capture on a solid sorbent OP 11 – část B (ČSN P CEN/TS 13649)","search_zh":"排放 固体吸附剂捕集法挥发性有机化合物（VOC）采样 OP 11 – část B (ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f42db3fa3381ada65100f94b","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"4","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Working air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Pobieranie próbek powietrza na stanowiskach pracy przez wychwyt na filtrze","methodology_en":"Sampling of workplace air by catching on a filter","methodology_zh":"滤膜捕集法工作场所空气采样","methodology_cs":"Odběr vzorku pracovního ovzduší záchytem na filtr","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza na stanowiskach pracy przez wychwyt na filtrze","reference":"OP 14 – část B (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC)","norm_bases":["OP 14 – část B","NV č. 361/2007 Sb.","ČSN EN 481","ČSN EN 689+AC"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Pobieranie próbek powietrza na stanowiskach pracy przez wychwyt na filtrze Pracovní ovzduší Odběr vzorku pracovního ovzduší záchytem na filtr OP 14 – část B (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC) Powietrze na stanowiskach pracy Pobieranie probek powietrza na stanowiskach pracy przez wychwyt na filtrze Pracovni ovzdusi Odber vzorku pracovniho ovzdusi zachytem na filtr OP 14 – cast B (NV c. 361/2007 Sb.; CSN EN 481; CSN EN 689+AC)","search_en":"Working air Sampling of workplace air by catching on a filter OP 14 – část B (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC)","search_zh":"工作场所空气 滤膜捕集法工作场所空气采样 OP 14 – část B (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 689+AC)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2b4bced6a0c748e55ad0ce59","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"5","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Working air","test_object_zh":"工作场所空气","test_object_cs":"Pracovní ovzduší","methodology":"Pobieranie próbek powietrza na stanowiskach pracy na sorbent stały","methodology_en":"Sampling of workplace air on a solid sorbent","methodology_zh":"固体吸附剂法工作场所空气采样","methodology_cs":"Odběr vzorku pracovního ovzduší na pevný sorbent","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza na stanowiskach pracy na sorbent stały","reference":"OP 15 – část B (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649)","norm_bases":["OP 15 – část B","NV č. 361/2007 Sb.","ČSN EN 482","ČSN EN 689+AC","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Pobieranie próbek powietrza na stanowiskach pracy na sorbent stały Pracovní ovzduší Odběr vzorku pracovního ovzduší na pevný sorbent OP 15 – část B (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649) Powietrze na stanowiskach pracy Pobieranie probek powietrza na stanowiskach pracy na sorbent staly Pracovni ovzdusi Odber vzorku pracovniho ovzdusi na pevny sorbent OP 15 – cast B (NV c. 361/2007 Sb.; CSN EN 482; CSN EN 689+AC; CSN P CEN/TS 13649)","search_en":"Working air Sampling of workplace air on a solid sorbent OP 15 – část B (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649)","search_zh":"工作场所空气 固体吸附剂法工作场所空气采样 OP 15 – část B (NV č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c16591bc86cb5e6e6e06e428","lab_id":"69ad52a4de79e566650fd456","country":"CZ","accr_number":"1510","accr_body":"ČIA","row_label":"6","test_object":"Emisje","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek do oznaczania chlorowodoru i chlorków przez absorpcję w roztworze - pobór nieizokinetyczny i ręczny izokinetyczny","methodology_en":"Sampling for the determination of hydrogen chloride and chlorides by absorption into solution – non-isokinetic and manual isokinetic sampling","methodology_zh":"溶液吸收法测定氯化氢和氯化物的采样 - 非等速及手动等速采样","methodology_cs":"Odběr vzorku pro stanovení chlorovodíku a chloridů absorpcí do roztoku - neizokinetický i manuální izokinetický odběr","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek do oznaczania chlorowodoru i chlorków przez absorpcję w roztworze - pobór nieizokinetyczny i ręczny izokinetyczny","reference":"OP 12 – část B (ČSN EN 1911)","norm_bases":["OP 12 – část B","ČSN EN 1911"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisje Pobieranie próbek do oznaczania chlorowodoru i chlorków przez absorpcję w roztworze - pobór nieizokinetyczny i ręczny izokinetyczny Emise Odběr vzorku pro stanovení chlorovodíku a chloridů absorpcí do roztoku - neizokinetický i manuální izokinetický odběr OP 12 – část B (ČSN EN 1911) Emisje Pobieranie probek do oznaczania chlorowodoru i chlorkow przez absorpcje w roztworze - pobor nieizokinetyczny i reczny izokinetyczny Emise Odber vzorku pro stanoveni chlorovodiku a chloridu absorpci do roztoku - neizokineticky i manualni izokineticky odber OP 12 – cast B (CSN EN 1911)","search_en":"Emissions Sampling for the determination of hydrogen chloride and chlorides by absorption into solution – non-isokinetic and manual isokinetic sampling OP 12 – část B (ČSN EN 1911)","search_zh":"排放 溶液吸收法测定氯化氢和氯化物的采样 - 非等速及手动等速采样 OP 12 – část B (ČSN EN 1911)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}