{"lab":{"_id":"69ad52a4de79e566650fd42e","accr_number":"1483","country":"CZ","accr_body":"ČIA","address":"Cejl 29/76, Zábrdovice, 602 00 Brno","categories":["environment"],"city":"Brno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":6,"name":"AKUSTING, spol. s r. o.","parse_status":"parsed","parse_version":5,"pdf_files":["1483_400_2024_CS.pdf","1483_400_2024_EN.pdf"],"scope_summary":"Pomiary hałasu w środowisku pracy i poza środowiskiem pracy, wyznaczanie mocy akustycznej, pomiary izolacyjności akustycznej od dźwięków powietrznych w budynkach, tłumienia wtrąceniowego, wyznaczanie izolacyjności akustycznej obudów, pomiary hałasu instalacji technicznych w budynkach.","search_text":"akusting, spol. s r. o. cejl 29/76, zábrdovice, 602 00 brno 1483","status":"active","updated_at":"2026-03-08T14:52:12.454Z","valid_from":"","valid_until":"15-08-2029","website":"","location":{"type":"Point","coordinates":[16.6068,49.1951]},"map_coord":[49.201689,16.626602],"map_geo":"nominatim-street","certificate_date":"15.08.2024","certificate_no":"400/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Pomiary hałasu w środowisku pracy i poza środowiskiem pracy, wyznaczanie mocy akustycznej, pomiary izolacyjności akustycznej od dźwięków powietrznych w budynkach, tłumienia wtrąceniowego, wyznaczanie izolacyjności akustycznej obudów, pomiary hałasu instalacji technicznych w budynkach.","en":"Measurement of noise in working and non-working environment, determination of sound power, measurement of airborne sound insulation, insertion loss, determination of sound insulation performances of enclosures, measurement of noise of technical equipment in buildings.","zh":"工作环境和非工作环境噪声的测量，声功率的测定，建筑空气声隔声、插入损失的测量，隔声罩隔声性能的测定，建筑物内技术设备噪声的测量。","cs":"Měření hluku v pracovním a mimopracovním prostředí, stanovení akustického výkonu, měření stavební vzduchové neprůzvučnosti, vložného útlumu, určování zvukové izolace krytů, měření hluku technických zařízení v budovách."}],"flexible_scope":true,"flexible_scope_url":"https://www.akusting.cz/o-nas/#politika-kvality","has_en":true,"has_zh":true,"lab_division":"Laboratorium Pomiarów Akustycznych","lab_division_cs":"Laboratoř akustických měření","lab_division_en":"Acoustic Measurement Laboratory","lab_division_zh":"声学测量实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"MZ ČR","pl":"Ministerstwo Zdrowia Republiki Czeskiej","en":"Ministry of Health of the Czech Republic","zh":"捷克共和国卫生部","cs":"Ministerstvo zdravotnictví České republiky"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."},{"pl":"Szczegółowe informacje o działalności w zakresie akredytacji (literatura źródłowa) podano w części „Upřesnění rozsahu akreditace” (doprecyzowanie zakresu akredytacji).","en":"Detailed information on activities within the scope of accreditation (source literature) is given in the section „Specification of the scope of accreditation“.","zh":"认可范围内活动的详细信息（参考文献）见“认可范围细化”部分。","cs":"Detailní informace k činnostem v rozsahu akreditace (zdrojová literatura) jsou uvedeny v části „Upřesnění rozsahu akreditace“."}],"source_lang":"cs","source_pdf_sha256":"cb4d3aa714337ae4e7e5d9c06aba7e850f004b6a94e4b7b259831ede8fae835b","source_pdf_url":"https://www.cai.cz/OA/pdf/P400_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P400_2024_EN.pdf"},"methods":[{"_id":"ce3059bba85043b26b116d32","lab_id":"69ad52a4de79e566650fd42e","country":"CZ","accr_number":"1483","accr_body":"ČIA","row_label":"1","test_object":"Środowisko pracy","test_object_en":"Workplace environment","test_object_zh":"工作环境","test_object_cs":"Pracovní prostředí","methodology":"Pomiar poziomu ciśnienia akustycznego","methodology_en":"Measurement of sound pressure level","methodology_zh":"声压级的测量","methodology_cs":"Měření hladiny akustického tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu ciśnienia akustycznego","reference":"ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11204; ČSN EN ISO 9612; Věstník MZ ČR, částka 4/2013","norm_bases":["ČSN EN ISO 11201","ČSN EN ISO 11202","ČSN EN ISO 11204","ČSN EN ISO 9612","Věstník MZ ČR, částka 4/2013"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":"Věstník MZ ČR, částka 4/2013 – wytyczne metodyczne do pomiaru i oceny hałasu poza środowiskiem pracy","note_en":"MoH CR Bulletin, Part 4/2013 - Guideline for the measurement and evaluation of noise in non-working environment","note_zh":"捷克卫生部公报第4/2013期 – 非工作环境噪声测量和评价方法指南","note_cs":"Věstník MZ ČR, částka 4/2013 - Metodický návod pro měření a hodnocení hluku v mimopracovním prostředí","search_text":"Środowisko pracy Pomiar poziomu ciśnienia akustycznego Pracovní prostředí Měření hladiny akustického tlaku ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11204; ČSN EN ISO 9612; Věstník MZ ČR, částka 4/2013 Srodowisko pracy Pomiar poziomu cisnienia akustycznego Pracovni prostredi Mereni hladiny akustickeho tlaku CSN EN ISO 11201; CSN EN ISO 11202; CSN EN ISO 11204; CSN EN ISO 9612; Vestnik MZ CR, castka 4/2013","search_en":"Workplace environment Measurement of sound pressure level ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11204; ČSN EN ISO 9612; Věstník MZ ČR, částka 4/2013","search_zh":"工作环境 声压级的测量 ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11204; ČSN EN ISO 9612; Věstník MZ ČR, částka 4/2013","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"45ee81bf34b20485a5c6137f","lab_id":"69ad52a4de79e566650fd42e","country":"CZ","accr_number":"1483","accr_body":"ČIA","row_label":"2","test_object":"Środowisko poza miejscem pracy","test_object_en":"Non-workplace environment","test_object_zh":"非工作环境","test_object_cs":"Mimopracovní prostředí","methodology":"Pomiar poziomu ciśnienia akustycznego","methodology_en":"Measurement of sound pressure level","methodology_zh":"声压级的测量","methodology_cs":"Měření hladiny akustického tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu ciśnienia akustycznego","reference":"ČSN ISO 1996-1; ČSN ISO 1996-2; ČSN EN ISO 16032; Věstník MZ ČR, částka 14/2023","norm_bases":["ČSN ISO 1996-1","ČSN ISO 1996-2","ČSN EN ISO 16032","Věstník MZ ČR, částka 14/2023"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":"Věstník MZ ČR, částka 14/2023 – wytyczne metodyczne do pomiaru i oceny hałasu i drgań na stanowisku pracy oraz drgań w chronionych pomieszczeniach budynków","note_en":"MoH CR Bulletin, Part 14/2023 - Guideline for the measurement and evaluation of noise and vibrations at workplace and vibrations in protected indoor areas of buildings","note_zh":"捷克卫生部公报第14/2023期 – 工作场所噪声和振动以及建筑物受保护室内空间振动测量和评价方法指南","note_cs":"Věstník MZ ČR, částka 14/2023 - Metodický návod pro měření a hodnocení hluku a vibrací na pracovišti a vibrací v chráněných vnitřních prostorech staveb","search_text":"Środowisko poza miejscem pracy Pomiar poziomu ciśnienia akustycznego Mimopracovní prostředí Měření hladiny akustického tlaku ČSN ISO 1996-1; ČSN ISO 1996-2; ČSN EN ISO 16032; Věstník MZ ČR, částka 14/2023 Srodowisko poza miejscem pracy Pomiar poziomu cisnienia akustycznego Mimopracovni prostredi Mereni hladiny akustickeho tlaku CSN ISO 1996-1; CSN ISO 1996-2; CSN EN ISO 16032; Vestnik MZ CR, castka 14/2023","search_en":"Non-workplace environment Measurement of sound pressure level ČSN ISO 1996-1; ČSN ISO 1996-2; ČSN EN ISO 16032; Věstník MZ ČR, částka 14/2023","search_zh":"非工作环境 声压级的测量 ČSN ISO 1996-1; ČSN ISO 1996-2; ČSN EN ISO 16032; Věstník MZ ČR, částka 14/2023","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4b26c3a2f333c89d626a963","lab_id":"69ad52a4de79e566650fd42e","country":"CZ","accr_number":"1483","accr_body":"ČIA","row_label":"3","test_object":"Źródła hałasu – maszyny i urządzenia","test_object_en":"Noise sources – machines and equipment","test_object_zh":"噪声源 – 机器和设备","test_object_cs":"Zdroje hluku – stroje a zařízení","methodology":"Wyznaczanie poziomu mocy akustycznej","methodology_en":"Determination of sound power level","methodology_zh":"声功率级的测定","methodology_cs":"Stanovení hladiny akustického výkonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie poziomu mocy akustycznej","reference":"ČSN EN ISO 3744; ČSN EN ISO 3746","norm_bases":["ČSN EN ISO 3744","ČSN EN ISO 3746"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Źródła hałasu – maszyny i urządzenia Wyznaczanie poziomu mocy akustycznej Zdroje hluku – stroje a zařízení Stanovení hladiny akustického výkonu ČSN EN ISO 3744; ČSN EN ISO 3746 Zrodla halasu – maszyny i urzadzenia Wyznaczanie poziomu mocy akustycznej Zdroje hluku – stroje a zarizeni Stanoveni hladiny akustickeho vykonu CSN EN ISO 3744; CSN EN ISO 3746","search_en":"Noise sources – machines and equipment Determination of sound power level ČSN EN ISO 3744; ČSN EN ISO 3746","search_zh":"噪声源 – 机器和设备 声功率级的测定 ČSN EN ISO 3744; ČSN EN ISO 3746","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac63843b1a0eb52f987dc2aa","lab_id":"69ad52a4de79e566650fd42e","country":"CZ","accr_number":"1483","accr_body":"ČIA","row_label":"4","test_object":"Przegrody budowlane","test_object_en":"Building partitioning structures","test_object_zh":"建筑隔断结构","test_object_cs":"Dělicí konstrukce stavby","methodology":"Pomiar izolacyjności od dźwięków powietrznych","methodology_en":"Measurement of airborne sound insulation","methodology_zh":"空气声隔声的测量","methodology_cs":"Měření vzduchové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności od dźwięków powietrznych","reference":"ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1","norm_bases":["ČSN EN ISO 16283-1","ČSN EN ISO 16283-3","ČSN EN ISO 717-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody budowlane Pomiar izolacyjności od dźwięków powietrznych Dělicí konstrukce stavby Měření vzduchové neprůzvučnosti ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1 Przegrody budowlane Pomiar izolacyjnosci od dzwiekow powietrznych Delici konstrukce stavby Mereni vzduchove nepruzvucnosti CSN EN ISO 16283-1; CSN EN ISO 16283-3; CSN EN ISO 717-1","search_en":"Building partitioning structures Measurement of airborne sound insulation ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1","search_zh":"建筑隔断结构 空气声隔声的测量 ČSN EN ISO 16283-1; ČSN EN ISO 16283-3; ČSN EN ISO 717-1","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b406cd0d6c7ef7d4b544ae70","lab_id":"69ad52a4de79e566650fd42e","country":"CZ","accr_number":"1483","accr_body":"ČIA","row_label":"5","test_object":"Przegrody obudów","test_object_en":"Partitioning structures of enclosures","test_object_zh":"隔声罩隔断结构","test_object_cs":"Dělicí konstrukce krytů","methodology":"Pomiar izolacyjności od dźwięków powietrznych","methodology_en":"Measurement of airborne sound insulation","methodology_zh":"空气声隔声的测量","methodology_cs":"Měření vzduchové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności od dźwięków powietrznych","reference":"ČSN EN ISO 11546-2","norm_bases":["ČSN EN ISO 11546-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody obudów Pomiar izolacyjności od dźwięków powietrznych Dělicí konstrukce krytů Měření vzduchové neprůzvučnosti ČSN EN ISO 11546-2 Przegrody obudow Pomiar izolacyjnosci od dzwiekow powietrznych Delici konstrukce krytu Mereni vzduchove nepruzvucnosti CSN EN ISO 11546-2","search_en":"Partitioning structures of enclosures Measurement of airborne sound insulation ČSN EN ISO 11546-2","search_zh":"隔声罩隔断结构 空气声隔声的测量 ČSN EN ISO 11546-2","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a2560c2914fcfe6642a3ad4c","lab_id":"69ad52a4de79e566650fd42e","country":"CZ","accr_number":"1483","accr_body":"ČIA","row_label":"6","test_object":"Pomieszczenia wewnętrzne","test_object_en":"Indoor areas","test_object_zh":"室内空间","test_object_cs":"Vnitřní prostory","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间的测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN EN ISO 3382-2; ČSN EN ISO 3382-1","norm_bases":["ČSN EN ISO 3382-2","ČSN EN ISO 3382-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia wewnętrzne Pomiar czasu pogłosu Vnitřní prostory Měření doby dozvuku ČSN EN ISO 3382-2; ČSN EN ISO 3382-1 Pomieszczenia wewnetrzne Pomiar czasu poglosu Vnitrni prostory Mereni doby dozvuku CSN EN ISO 3382-2; CSN EN ISO 3382-1","search_en":"Indoor areas Measurement of reverberation time ČSN EN ISO 3382-2; ČSN EN ISO 3382-1","search_zh":"室内空间 混响时间的测量 ČSN EN ISO 3382-2; ČSN EN ISO 3382-1","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}