{"lab":{"_id":"69ad52a4de79e566650fd3de","accr_number":"1427","country":"CZ","accr_body":"ČIA","address":"Kovohutě 530, Příbram VI-Březové Hory, 261 01 Příbram","categories":["materials","water"],"city":"Příbram","imported_at":"2026-03-08T10:42:44.590Z","methods_count":10,"name":"Kovohutě Příbram nástupnická, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1427_189_2022_CS.pdf","1427_189_2022_EN.pdf"],"scope_summary":"Analiza chemiczna stopów na bazie ołowiu i cyny, analiza wód powierzchniowych, podziemnych i ścieków, analiza wyciągów wodnych.","search_text":"kovohutě příbram nástupnická, a.s. kovohutě 530, příbram vi-březové hory, 261 01 příbram 1427","status":"active","updated_at":"2026-03-08T14:52:11.773Z","valid_from":"","valid_until":"20-04-2027","website":"www.kovopb.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.kovopb.cz","map_coord":[49.707349,13.983006],"map_geo":"nominatim-street","certificate_date":"20.04.2022","certificate_no":"189/2022","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Analiza chemiczna stopów na bazie ołowiu i cyny, analiza wód powierzchniowych, podziemnych i ścieków, analiza wyciągów wodnych.","en":"Chemical analysis of lead and tin based alloys, analysis of surface, ground and waste water, analysis of aqueous extracts.","zh":"铅基和锡基合金的化学分析，地表水、地下水和废水的分析，水浸出液的分析。","cs":"Chemická analýza slitin na bázi olova a cínu, analýza povrchových, podzemních a odpadních vod, analýza vodných výluhů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium","lab_division_cs":"Laboratoř","lab_division_en":"Laboratory","lab_division_zh":"实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"AAS","pl":"Atomowa spektrometria absorpcyjna","en":"Atomic Absorption Spectrometry","zh":"原子吸收光谱法","cs":"Atomová absorpční spektrometrie"},{"abbr":"ICP","pl":"Plazma sprzężona indukcyjnie","en":"Inductively Coupled Plasma","zh":"电感耦合等离子体","cs":"Indukčně vázaná plasma"},{"abbr":"OES","pl":"Optyczna spektrometria emisyjna","en":"Optical Emission Spectrometry","zh":"光学发射光谱法","cs":"Optická emisní spektrometrie"},{"abbr":"RL","pl":"Substancje rozpuszczone","en":"Dissolved Solids","zh":"溶解性固体","cs":"Rozpuštěné látky"},{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard Operating Procedure","zh":"标准操作程序","cs":"Standardní operační postup"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"1f571bfccd9b753638f531aa7610fdb0ed6b67e74fa3a59883c86d7104cd86a8","source_pdf_url":"https://www.cai.cz/OA/pdf/P189_2022_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P189_2022_EN.pdf"},"methods":[{"_id":"e2f47ea802ebaf669685fd83","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"1","test_object":"Stopy na bazie ołowiu i cyny","test_object_en":"Lead and tin base alloys","test_object_zh":"铅基和锡基合金","test_object_cs":"Slitiny na bázi olova a cínu","methodology":"Oznaczanie pierwiastków Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn metodą AAS z atomizacją w płomieniu","methodology_en":"Determination of elements Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn by AAS method with flame atomization","methodology_zh":"火焰原子化AAS法测定元素Ag、Al、As、Bi、Ca、Cd、Cu、Fe、In、Ni、Pb、Sb、Se、Sn、Te、Tl、Zn","methodology_cs":"Stanovení prvků Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn metodou AAS s plamenovou atomizací","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bizmut (Bi)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Ind (In)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Tellur (Te)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Bismuth (Bi)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Indium (In)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Tellurium (Te)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"铋（Bi）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"铟（In）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"碲（Te）","range":""},{"name":"铊（Tl）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"Bi","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"In","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Te","range":""},{"name":"Tl","range":""},{"name":"Zn","range":""}],"technique":"Płomieniowa atomowa spektrometria absorpcyjna (FAAS)","technique_en":"AAS with flame atomization","technique_zh":"火焰原子吸收光谱法","technique_cs":"AAS s plamenovou atomizací","techniques":["Płomieniowa atomowa spektrometria absorpcyjna (FAAS)"],"techniques_en":["AAS with flame atomization"],"techniques_zh":["火焰原子吸收光谱法"],"techniques_cs":["AAS s plamenovou atomizací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn metodą AAS z atomizacją w płomieniu\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBizmut (Bi)\nWapń (Ca)\nKadm (Cd)\nMiedź (Cu)\nŻelazo (Fe)\nInd (In)\nNikiel (Ni)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nTellur (Te)\nTal (Tl)\nCynk (Zn)\nPłomieniowa atomowa spektrometria absorpcyjna (FAAS)","reference":"SOP-A1 (ČSN 42 0614-2, ČSN 42 0614-3, ČSN 42 0614-5, ČSN 42 0614-6, ČSN 42 0614-8, ČSN 42 0614-11, ČSN 42 0614-13, ČSN 42 0614-16, ČSN 42 0614-17, ČSN 42 0614-19, ČSN 42 0614-21)","norm_bases":["SOP-A1","ČSN 42 0614-2","ČSN 42 0614-3","ČSN 42 0614-5","ČSN 42 0614-6","ČSN 42 0614-8","ČSN 42 0614-11","ČSN 42 0614-13","ČSN 42 0614-16","ČSN 42 0614-17","ČSN 42 0614-19","ČSN 42 0614-21"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy na bazie ołowiu i cyny Oznaczanie pierwiastków Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn metodą AAS z atomizacją w płomieniu Płomieniowa atomowa spektrometria absorpcyjna (FAAS) Srebro (Ag)  Glin (Al)  Arsen (As)  Bizmut (Bi)  Wapń (Ca)  Kadm (Cd)  Miedź (Cu)  Żelazo (Fe)  Ind (In)  Nikiel (Ni)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Cynk (Zn)  Slitiny na bázi olova a cínu Stanovení prvků Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn metodou AAS s plamenovou atomizací AAS s plamenovou atomizací Ag  Al  As  Bi  Ca  Cd  Cu  Fe  In  Ni  Pb  Sb  Se  Sn  Te  Tl  Zn  SOP-A1 (ČSN 42 0614-2, ČSN 42 0614-3, ČSN 42 0614-5, ČSN 42 0614-6, ČSN 42 0614-8, ČSN 42 0614-11, ČSN 42 0614-13, ČSN 42 0614-16, ČSN 42 0614-17, ČSN 42 0614-19, ČSN 42 0614-21) Stopy na bazie olowiu i cyny Oznaczanie pierwiastkow Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn metoda AAS z atomizacja w plomieniu Plomieniowa atomowa spektrometria absorpcyjna (FAAS) Srebro (Ag)  Glin (Al)  Arsen (As)  Bizmut (Bi)  Wapn (Ca)  Kadm (Cd)  Miedz (Cu)  Zelazo (Fe)  Ind (In)  Nikiel (Ni)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Cynk (Zn)  Slitiny na bazi olova a cinu Stanoveni prvku Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn metodou AAS s plamenovou atomizaci AAS s plamenovou atomizaci Ag  Al  As  Bi  Ca  Cd  Cu  Fe  In  Ni  Pb  Sb  Se  Sn  Te  Tl  Zn  SOP-A1 (CSN 42 0614-2, CSN 42 0614-3, CSN 42 0614-5, CSN 42 0614-6, CSN 42 0614-8, CSN 42 0614-11, CSN 42 0614-13, CSN 42 0614-16, CSN 42 0614-17, CSN 42 0614-19, CSN 42 0614-21)","search_en":"Lead and tin base alloys Determination of elements Ag, Al, As, Bi, Ca, Cd, Cu, Fe, In, Ni, Pb, Sb, Se, Sn, Te, Tl, Zn by AAS method with flame atomization AAS with flame atomization Silver (Ag)  Aluminium (Al)  Arsenic (As)  Bismuth (Bi)  Calcium (Ca)  Cadmium (Cd)  Copper (Cu)  Iron (Fe)  Indium (In)  Nickel (Ni)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Tellurium (Te)  Thallium (Tl)  Zinc (Zn)  SOP-A1 (ČSN 42 0614-2, ČSN 42 0614-3, ČSN 42 0614-5, ČSN 42 0614-6, ČSN 42 0614-8, ČSN 42 0614-11, ČSN 42 0614-13, ČSN 42 0614-16, ČSN 42 0614-17, ČSN 42 0614-19, ČSN 42 0614-21)","search_zh":"铅基和锡基合金 火焰原子化AAS法测定元素Ag、Al、As、Bi、Ca、Cd、Cu、Fe、In、Ni、Pb、Sb、Se、Sn、Te、Tl、Zn 火焰原子吸收光谱法 银（Ag）  铝（Al）  砷（As）  铋（Bi）  钙（Ca）  镉（Cd）  铜（Cu）  铁（Fe）  铟（In）  镍（Ni）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  碲（Te）  铊（Tl）  锌（Zn）  SOP-A1 (ČSN 42 0614-2, ČSN 42 0614-3, ČSN 42 0614-5, ČSN 42 0614-6, ČSN 42 0614-8, ČSN 42 0614-11, ČSN 42 0614-13, ČSN 42 0614-16, ČSN 42 0614-17, ČSN 42 0614-19, ČSN 42 0614-21)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a7d1f8ecd36e4b9455ad1c62","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"2","test_object":"Stopy na bazie ołowiu i cyny","test_object_en":"Lead and tin base alloys","test_object_zh":"铅基和锡基合金","test_object_cs":"Slitiny na bázi olova a cínu","methodology":"Oznaczanie pierwiastków Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn metodą OES na kwantometrze","methodology_en":"Determination of elements Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn by OES method on quantometer","methodology_zh":"光量计OES法测定元素Ag、Al、As、Au、Bi、Ca、Cd、Cu、Fe、In、Ni、P、Pb、S、Sb、Se、Sn、Te、Tl、Zn","methodology_cs":"Stanovení prvků Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn metodou OES na kvantometru","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Złoto (Au)","range":""},{"name":"Bizmut (Bi)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Ind (In)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Siarka (S)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Tellur (Te)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Gold (Au)","range":""},{"name":"Bismuth (Bi)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Indium (In)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Tellurium (Te)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"金（Au）","range":""},{"name":"铋（Bi）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"铟（In）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"硫（S）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"碲（Te）","range":""},{"name":"铊（Tl）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"Au","range":""},{"name":"Bi","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"In","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"S","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Te","range":""},{"name":"Tl","range":""},{"name":"Zn","range":""}],"technique":"Optyczna spektrometria emisyjna (kwantometr)","technique_en":"OES on quantometer","technique_zh":"光量计光学发射光谱法","technique_cs":"OES na kvantometru","techniques":["Optyczna spektrometria emisyjna (kwantometr)"],"techniques_en":["OES on quantometer"],"techniques_zh":["光量计光学发射光谱法"],"techniques_cs":["OES na kvantometru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn metodą OES na kwantometrze\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nZłoto (Au)\nBizmut (Bi)\nWapń (Ca)\nKadm (Cd)\nMiedź (Cu)\nŻelazo (Fe)\nInd (In)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nSiarka (S)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nTellur (Te)\nTal (Tl)\nCynk (Zn)\nOptyczna spektrometria emisyjna (kwantometr)","reference":"SOP-K1 (ENV 12908)","norm_bases":["SOP-K1","ENV 12908"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy na bazie ołowiu i cyny Oznaczanie pierwiastków Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn metodą OES na kwantometrze Optyczna spektrometria emisyjna (kwantometr) Srebro (Ag)  Glin (Al)  Arsen (As)  Złoto (Au)  Bizmut (Bi)  Wapń (Ca)  Kadm (Cd)  Miedź (Cu)  Żelazo (Fe)  Ind (In)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Siarka (S)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Cynk (Zn)  Slitiny na bázi olova a cínu Stanovení prvků Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn metodou OES na kvantometru OES na kvantometru Ag  Al  As  Au  Bi  Ca  Cd  Cu  Fe  In  Ni  P  Pb  S  Sb  Se  Sn  Te  Tl  Zn  SOP-K1 (ENV 12908) Stopy na bazie olowiu i cyny Oznaczanie pierwiastkow Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn metoda OES na kwantometrze Optyczna spektrometria emisyjna (kwantometr) Srebro (Ag)  Glin (Al)  Arsen (As)  Zloto (Au)  Bizmut (Bi)  Wapn (Ca)  Kadm (Cd)  Miedz (Cu)  Zelazo (Fe)  Ind (In)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Siarka (S)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Cynk (Zn)  Slitiny na bazi olova a cinu Stanoveni prvku Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn metodou OES na kvantometru OES na kvantometru Ag  Al  As  Au  Bi  Ca  Cd  Cu  Fe  In  Ni  P  Pb  S  Sb  Se  Sn  Te  Tl  Zn  SOP-K1 (ENV 12908)","search_en":"Lead and tin base alloys Determination of elements Ag, Al, As, Au, Bi, Ca, Cd, Cu, Fe, In, Ni, P, Pb, S, Sb, Se, Sn, Te, Tl, Zn by OES method on quantometer OES on quantometer Silver (Ag)  Aluminium (Al)  Arsenic (As)  Gold (Au)  Bismuth (Bi)  Calcium (Ca)  Cadmium (Cd)  Copper (Cu)  Iron (Fe)  Indium (In)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Sulphur (S)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Tellurium (Te)  Thallium (Tl)  Zinc (Zn)  SOP-K1 (ENV 12908)","search_zh":"铅基和锡基合金 光量计OES法测定元素Ag、Al、As、Au、Bi、Ca、Cd、Cu、Fe、In、Ni、P、Pb、S、Sb、Se、Sn、Te、Tl、Zn 光量计光学发射光谱法 银（Ag）  铝（Al）  砷（As）  金（Au）  铋（Bi）  钙（Ca）  镉（Cd）  铜（Cu）  铁（Fe）  铟（In）  镍（Ni）  磷（P）  铅（Pb）  硫（S）  锑（Sb）  硒（Se）  锡（Sn）  碲（Te）  铊（Tl）  锌（Zn）  SOP-K1 (ENV 12908)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"afa8c7e97b9da5e1bc4c74c3","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"3","test_object":"Stopy na bazie ołowiu i cyny","test_object_en":"Lead and tin base alloys","test_object_zh":"铅基和锡基合金","test_object_cs":"Slitiny na bázi olova a cínu","methodology":"Miareczkowe oznaczanie Ag roztworem NH4SCN","methodology_en":"Titrimetric determination of Ag using NH4SCN solution","methodology_zh":"NH4SCN溶液滴定法测定Ag","methodology_cs":"Titrační stanovení Ag roztokem NH4SCN","parameters":[{"name":"Srebro (Ag)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""}],"parameters_cs":[{"name":"Ag","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Miareczkowe oznaczanie Ag roztworem NH4SCN\nSrebro (Ag)","reference":"SOP-T1 (ČSN 42 0655-1)","norm_bases":["SOP-T1","ČSN 42 0655-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy na bazie ołowiu i cyny Miareczkowe oznaczanie Ag roztworem NH4SCN Srebro (Ag)  Slitiny na bázi olova a cínu Titrační stanovení Ag roztokem NH4SCN Ag  SOP-T1 (ČSN 42 0655-1) Stopy na bazie olowiu i cyny Miareczkowe oznaczanie Ag roztworem NH4SCN Srebro (Ag)  Slitiny na bazi olova a cinu Titracni stanoveni Ag roztokem NH4SCN Ag  SOP-T1 (CSN 42 0655-1)","search_en":"Lead and tin base alloys Titrimetric determination of Ag using NH4SCN solution Silver (Ag)  SOP-T1 (ČSN 42 0655-1)","search_zh":"铅基和锡基合金 NH4SCN溶液滴定法测定Ag 银（Ag）  SOP-T1 (ČSN 42 0655-1)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5eede45c7d2c5b5ef2986b95","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"4","test_object":"Stopy na bazie ołowiu i cyny","test_object_en":"Lead and tin base alloys","test_object_zh":"铅基和锡基合金","test_object_cs":"Slitiny na bázi olova a cínu","methodology":"Miareczkowe oznaczanie Sn roztworem jodu","methodology_en":"Titrimetric determination of Sn using iodine solution","methodology_zh":"碘溶液滴定法测定Sn","methodology_cs":"Titrační stanovení Sn roztokem jodu","parameters":[{"name":"Cyna (Sn)","range":""}],"parameters_en":[{"name":"Tin (Sn)","range":""}],"parameters_zh":[{"name":"锡（Sn）","range":""}],"parameters_cs":[{"name":"Sn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Miareczkowe oznaczanie Sn roztworem jodu\nCyna (Sn)","reference":"SOP-T2 (ČSN 42 0614-1)","norm_bases":["SOP-T2","ČSN 42 0614-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy na bazie ołowiu i cyny Miareczkowe oznaczanie Sn roztworem jodu Cyna (Sn)  Slitiny na bázi olova a cínu Titrační stanovení Sn roztokem jodu Sn  SOP-T2 (ČSN 42 0614-1) Stopy na bazie olowiu i cyny Miareczkowe oznaczanie Sn roztworem jodu Cyna (Sn)  Slitiny na bazi olova a cinu Titracni stanoveni Sn roztokem jodu Sn  SOP-T2 (CSN 42 0614-1)","search_en":"Lead and tin base alloys Titrimetric determination of Sn using iodine solution Tin (Sn)  SOP-T2 (ČSN 42 0614-1)","search_zh":"铅基和锡基合金 碘溶液滴定法测定Sn 锡（Sn）  SOP-T2 (ČSN 42 0614-1)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bb988e948a6b803308eb908","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"5","test_object":"Stopy na bazie ołowiu i cyny","test_object_en":"Lead and tin base alloys","test_object_zh":"铅基和锡基合金","test_object_cs":"Slitiny na bázi olova a cínu","methodology":"Miareczkowe oznaczanie Sb roztworem KBrO3","methodology_en":"Titrimetric determination of Sb using KBrO3 solution","methodology_zh":"KBrO3溶液滴定法测定Sb","methodology_cs":"Titrační stanovení Sb roztokem KBrO3","parameters":[{"name":"Antymon (Sb)","range":""}],"parameters_en":[{"name":"Antimony (Sb)","range":""}],"parameters_zh":[{"name":"锑（Sb）","range":""}],"parameters_cs":[{"name":"Sb","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Miareczkowe oznaczanie Sb roztworem KBrO3\nAntymon (Sb)","reference":"SOP-T3 (ČSN 42 0614-4)","norm_bases":["SOP-T3","ČSN 42 0614-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy na bazie ołowiu i cyny Miareczkowe oznaczanie Sb roztworem KBrO3 Antymon (Sb)  Slitiny na bázi olova a cínu Titrační stanovení Sb roztokem KBrO3 Sb  SOP-T3 (ČSN 42 0614-4) Stopy na bazie olowiu i cyny Miareczkowe oznaczanie Sb roztworem KBrO3 Antymon (Sb)  Slitiny na bazi olova a cinu Titracni stanoveni Sb roztokem KBrO3 Sb  SOP-T3 (CSN 42 0614-4)","search_en":"Lead and tin base alloys Titrimetric determination of Sb using KBrO3 solution Antimony (Sb)  SOP-T3 (ČSN 42 0614-4)","search_zh":"铅基和锡基合金 KBrO3溶液滴定法测定Sb 锑（Sb）  SOP-T3 (ČSN 42 0614-4)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"672c1941e0f664bb0ec14bce","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"6","test_object":"Wody powierzchniowe, ścieki, wody podziemne, wyciągi wodne z odpadów ziarnistych i osadów","test_object_en":"Surface, waste, ground water, extracts of granular waste and sludge","test_object_zh":"地表水、废水、地下水、粒状废物和污泥浸出液","test_object_cs":"Vody povrchové, odpadní, podzemní, výluhy zrnitých odpadů a kalů","methodology":"Oznaczanie Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, siarczanów, chlorków metodą ICP-OES","methodology_en":"Determination Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, sulphates, chlorides by ICP-OES method","methodology_zh":"ICP-OES法测定Al、As、B、Ba、Be、Cd、Co、Cr、Cu、Fe、Mn、Mo、Ni、P、Pb、Sb、Se、Sn、Tl、V、Zn、硫酸盐、氯化物","methodology_cs":"Stanovení Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, sírany, chloridy metodou ICP-OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"siarczany","range":""},{"name":"chlorki","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"sulphates","range":""},{"name":"chlorides","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"铊（Tl）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""},{"name":"硫酸盐","range":""},{"name":"氯化物","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Tl","range":""},{"name":"V","range":""},{"name":"Zn","range":""},{"name":"sírany","range":""},{"name":"chloridy","range":""}],"technique":"Atomowa spektrometria emisyjna z plazmą wzbudzoną indukcyjnie (ICP-OES)","technique_en":"ICP-OES","technique_zh":"电感耦合等离子体发射光谱法(ICP-OES)","technique_cs":"ICP-OES","techniques":["Atomowa spektrometria emisyjna z plazmą wzbudzoną indukcyjnie (ICP-OES)"],"techniques_en":["ICP-OES"],"techniques_zh":["电感耦合等离子体发射光谱法(ICP-OES)"],"techniques_cs":["ICP-OES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, siarczanów, chlorków metodą ICP-OES\nZakres:\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nMangan (Mn)\nMolibden (Mo)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nTal (Tl)\nWanad (V)\nCynk (Zn)\nsiarczany\nchlorki\nAtomowa spektrometria emisyjna z plazmą wzbudzoną indukcyjnie (ICP-OES)","reference":"SOP-ICP1 (ČSN EN ISO 11885)","norm_bases":["SOP-ICP1","ČSN EN ISO 11885"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki, wody podziemne, wyciągi wodne z odpadów ziarnistych i osadów Oznaczanie Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, siarczanów, chlorków metodą ICP-OES Atomowa spektrometria emisyjna z plazmą wzbudzoną indukcyjnie (ICP-OES) Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tal (Tl)  Wanad (V)  Cynk (Zn)  siarczany  chlorki  Vody povrchové, odpadní, podzemní, výluhy zrnitých odpadů a kalů Stanovení Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, sírany, chloridy metodou ICP-OES ICP-OES Al  As  B  Ba  Be  Cd  Co  Cr  Cu  Fe  Mn  Mo  Ni  P  Pb  Sb  Se  Sn  Tl  V  Zn  sírany  chloridy  SOP-ICP1 (ČSN EN ISO 11885) Wody powierzchniowe, scieki, wody podziemne, wyciagi wodne z odpadow ziarnistych i osadow Oznaczanie Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, siarczanow, chlorkow metoda ICP-OES Atomowa spektrometria emisyjna z plazma wzbudzona indukcyjnie (ICP-OES) Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tal (Tl)  Wanad (V)  Cynk (Zn)  siarczany  chlorki  Vody povrchove, odpadni, podzemni, vyluhy zrnitych odpadu a kalu Stanoveni Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, sirany, chloridy metodou ICP-OES ICP-OES Al  As  B  Ba  Be  Cd  Co  Cr  Cu  Fe  Mn  Mo  Ni  P  Pb  Sb  Se  Sn  Tl  V  Zn  sirany  chloridy  SOP-ICP1 (CSN EN ISO 11885)","search_en":"Surface, waste, ground water, extracts of granular waste and sludge Determination Al, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Tl, V, Zn, sulphates, chlorides by ICP-OES method ICP-OES Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Manganese (Mn)  Molybdenum (Mo)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Thallium (Tl)  Vanadium (V)  Zinc (Zn)  sulphates  chlorides  SOP-ICP1 (ČSN EN ISO 11885)","search_zh":"地表水、废水、地下水、粒状废物和污泥浸出液 ICP-OES法测定Al、As、B、Ba、Be、Cd、Co、Cr、Cu、Fe、Mn、Mo、Ni、P、Pb、Sb、Se、Sn、Tl、V、Zn、硫酸盐、氯化物 电感耦合等离子体发射光谱法(ICP-OES) 铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  锰（Mn）  钼（Mo）  镍（Ni）  磷（P）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  铊（Tl）  钒（V）  锌（Zn）  硫酸盐  氯化物  SOP-ICP1 (ČSN EN ISO 11885)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4b7ab7161c7c382689b731d5","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"7","test_object":"Wody powierzchniowe, ścieki, wody podziemne, wyciągi wodne z odpadów ziarnistych i osadów","test_object_en":"Surface, waste, ground water, extracts of granular waste and sludge","test_object_zh":"地表水、废水、地下水、粒状废物和污泥浸出液","test_object_cs":"Vody povrchové, odpadní, podzemní, výluhy zrnitých odpadů a kalů","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Potentiometric determination of pH","methodology_zh":"电位法测定pH值","methodology_cs":"Stanovení pH metodou potenciometrickou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP-P1 (ČSN ISO 10523)","norm_bases":["SOP-P1","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki, wody podziemne, wyciągi wodne z odpadów ziarnistych i osadów Oznaczanie pH metodą potencjometryczną Vody povrchové, odpadní, podzemní, výluhy zrnitých odpadů a kalů Stanovení pH metodou potenciometrickou SOP-P1 (ČSN ISO 10523) Wody powierzchniowe, scieki, wody podziemne, wyciagi wodne z odpadow ziarnistych i osadow Oznaczanie pH metoda potencjometryczna Vody povrchove, odpadni, podzemni, vyluhy zrnitych odpadu a kalu Stanoveni pH metodou potenciometrickou SOP-P1 (CSN ISO 10523)","search_en":"Surface, waste, ground water, extracts of granular waste and sludge Potentiometric determination of pH SOP-P1 (ČSN ISO 10523)","search_zh":"地表水、废水、地下水、粒状废物和污泥浸出液 电位法测定pH值 SOP-P1 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14fe755060e41aef2752a23e","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"8","test_object":"Wody powierzchniowe, ścieki, wody podziemne, wyciągi wodne z odpadów ziarnistych i osadów","test_object_en":"Surface, waste, ground water, extracts of granular waste and sludge","test_object_zh":"地表水、废水、地下水、粒状废物和污泥浸出液","test_object_cs":"Vody povrchové, odpadní, podzemní, výluhy zrnitých odpadů a kalů","methodology":"Oznaczanie substancji rozpuszczonych metodą wagową: 1) suszonych w 105 °C – RL 105, 2) prażonych w 550 °C – RL 550, 3) rozpuszczonych soli nieorganicznych – RAS","methodology_en":"Determination of dissolved solids by gravimetry 1) dried at 105°C – RL 105 2) annealed at 550°C – RL 550 3) dissolved inorganic salts – RAS","methodology_zh":"重量法测定溶解性固体：1) 105°C烘干 – RL 105；2) 550°C灼烧 – RL 550；3) 溶解性无机盐 – RAS","methodology_cs":"Stanovení rozpuštěných látek gravimetricky 1) sušených při 105°C – RL 105 2) žíhaných při 550°C – RL 550 3) rozpuštěných anorganických solí – RAS","parameters":[{"name":"substancje rozpuszczone suszone w 105 °C (RL 105)","range":""},{"name":"substancje rozpuszczone prażone w 550 °C (RL 550)","range":""},{"name":"rozpuszczone sole nieorganiczne (RAS)","range":""}],"parameters_en":[{"name":"dissolved solids dried at 105 °C (RL 105)","range":""},{"name":"dissolved solids annealed at 550 °C (RL 550)","range":""},{"name":"dissolved inorganic salts (RAS)","range":""}],"parameters_zh":[{"name":"105 °C烘干溶解性固体（RL 105）","range":""},{"name":"550 °C灼烧溶解性固体（RL 550）","range":""},{"name":"溶解性无机盐（RAS）","range":""}],"parameters_cs":[{"name":"RL 105","range":""},{"name":"RL 550","range":""},{"name":"RAS","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych metodą wagową: 1) suszonych w 105 °C – RL 105, 2) prażonych w 550 °C – RL 550, 3) rozpuszczonych soli nieorganicznych – RAS\nZakres:\nsubstancje rozpuszczone suszone w 105 °C (RL 105)\nsubstancje rozpuszczone prażone w 550 °C (RL 550)\nrozpuszczone sole nieorganiczne (RAS)","reference":"SOP-RL1 (ČSN 75 7346, ČSN 75 7347)","norm_bases":["SOP-RL1","ČSN 75 7346","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki, wody podziemne, wyciągi wodne z odpadów ziarnistych i osadów Oznaczanie substancji rozpuszczonych metodą wagową: 1) suszonych w 105 °C – RL 105, 2) prażonych w 550 °C – RL 550, 3) rozpuszczonych soli nieorganicznych – RAS substancje rozpuszczone suszone w 105 °C (RL 105)  substancje rozpuszczone prażone w 550 °C (RL 550)  rozpuszczone sole nieorganiczne (RAS)  Vody povrchové, odpadní, podzemní, výluhy zrnitých odpadů a kalů Stanovení rozpuštěných látek gravimetricky 1) sušených při 105°C – RL 105 2) žíhaných při 550°C – RL 550 3) rozpuštěných anorganických solí – RAS RL 105  RL 550  RAS  SOP-RL1 (ČSN 75 7346, ČSN 75 7347) Wody powierzchniowe, scieki, wody podziemne, wyciagi wodne z odpadow ziarnistych i osadow Oznaczanie substancji rozpuszczonych metoda wagowa: 1) suszonych w 105 °C – RL 105, 2) prazonych w 550 °C – RL 550, 3) rozpuszczonych soli nieorganicznych – RAS substancje rozpuszczone suszone w 105 °C (RL 105)  substancje rozpuszczone prazone w 550 °C (RL 550)  rozpuszczone sole nieorganiczne (RAS)  Vody povrchove, odpadni, podzemni, vyluhy zrnitych odpadu a kalu Stanoveni rozpustenych latek gravimetricky 1) susenych pri 105°C – RL 105 2) zihanych pri 550°C – RL 550 3) rozpustenych anorganickych soli – RAS RL 105  RL 550  RAS  SOP-RL1 (CSN 75 7346, CSN 75 7347)","search_en":"Surface, waste, ground water, extracts of granular waste and sludge Determination of dissolved solids by gravimetry 1) dried at 105°C – RL 105 2) annealed at 550°C – RL 550 3) dissolved inorganic salts – RAS dissolved solids dried at 105 °C (RL 105)  dissolved solids annealed at 550 °C (RL 550)  dissolved inorganic salts (RAS)  SOP-RL1 (ČSN 75 7346, ČSN 75 7347)","search_zh":"地表水、废水、地下水、粒状废物和污泥浸出液 重量法测定溶解性固体：1) 105°C烘干 – RL 105；2) 550°C灼烧 – RL 550；3) 溶解性无机盐 – RAS 105 °C烘干溶解性固体（RL 105）  550 °C灼烧溶解性固体（RL 550）  溶解性无机盐（RAS）  SOP-RL1 (ČSN 75 7346, ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"13981f4c64a04557d324e9bd","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"9","test_object":"Wody powierzchniowe, ścieki, wody podziemne","test_object_en":"Surface, waste, ground water","test_object_zh":"地表水、废水、地下水","test_object_cs":"Vody povrchové, odpadní, podzemní","methodology":"Oznaczanie zawiesiny ogólnej metodą wagową","methodology_en":"Determination of suspended solids by gravimetry","methodology_zh":"重量法测定悬浮物","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny ogólnej metodą wagową","reference":"SOP-NL1 (ČSN EN 872)","norm_bases":["SOP-NL1","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki, wody podziemne Oznaczanie zawiesiny ogólnej metodą wagową Vody povrchové, odpadní, podzemní Stanovení nerozpuštěných látek gravimetricky SOP-NL1 (ČSN EN 872) Wody powierzchniowe, scieki, wody podziemne Oznaczanie zawiesiny ogolnej metoda wagowa Vody povrchove, odpadni, podzemni Stanoveni nerozpustenych latek gravimetricky SOP-NL1 (CSN EN 872)","search_en":"Surface, waste, ground water Determination of suspended solids by gravimetry SOP-NL1 (ČSN EN 872)","search_zh":"地表水、废水、地下水 重量法测定悬浮物 SOP-NL1 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd6e0aebf89912e03074198e","lab_id":"69ad52a4de79e566650fd3de","country":"CZ","accr_number":"1427","accr_body":"ČIA","row_label":"10","test_object":"Stopy na bazie ołowiu","test_object_en":"Lead based alloys","test_object_zh":"铅基合金","test_object_cs":"Slitiny na bázi olova","methodology":"Oznaczanie srebra metodą wagową (kupelacja)","methodology_en":"Determination of silver by gravimetry (docimasia)","methodology_zh":"重量法（灰吹法）测定银","methodology_cs":"Stanovení stříbra gravimetricky dokimasií","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie srebra metodą wagową (kupelacja)","reference":"SOP-Ag D1 (ČSN 42 0614-10)","norm_bases":["SOP-Ag D1","ČSN 42 0614-10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy na bazie ołowiu Oznaczanie srebra metodą wagową (kupelacja) Slitiny na bázi olova Stanovení stříbra gravimetricky dokimasií SOP-Ag D1 (ČSN 42 0614-10) Stopy na bazie olowiu Oznaczanie srebra metoda wagowa (kupelacja) Slitiny na bazi olova Stanoveni stribra gravimetricky dokimasii SOP-Ag D1 (CSN 42 0614-10)","search_en":"Lead based alloys Determination of silver by gravimetry (docimasia) SOP-Ag D1 (ČSN 42 0614-10)","search_zh":"铅基合金 重量法（灰吹法）测定银 SOP-Ag D1 (ČSN 42 0614-10)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}