{"lab":{"_id":"69ad52a4de79e566650fd3dc","accr_number":"1426","country":"CZ","accr_body":"ČIA","address":"Čížkovice čp. 27, 411 12 Čížkovice","categories":["construction"],"city":"Čížkovice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":9,"name":"Holcim (Česko), a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1426_358_2023_CS.pdf","1426_358_2023_EN.pdf"],"scope_summary":"Badania mieszanki betonowej, betonu stwardniałego i kruszywa.","search_text":"holcim (česko), a.s. čížkovice čp. 27, 411 12 čížkovice 1426","status":"active","updated_at":"2026-03-08T14:52:11.772Z","valid_from":"","valid_until":"10-03-2027","website":"www.holcim.cz","map_coord":[50.484179,14.028394],"map_geo":"nominatim-city","certificate_date":"07.07.2023","certificate_no":"358/2023","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania mieszanki betonowej, betonu stwardniałego i kruszywa.","en":"Testing of fresh and hardened concrete and aggregate.","zh":"新拌和硬化混凝土及集料的检测。","cs":"Zkoušení čerstvého a ztvrdlého betonu a kameniva."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Betonu","lab_division_cs":"Betonářská laboratoř","lab_division_en":"Concrete Laboratory","lab_division_zh":"混凝土实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"2dc86f46fdb3c0ee470752201b9636f8ae9987cead3956777cbf495e5888b77a","source_pdf_url":"https://www.cai.cz/OA/pdf/P358_2023_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"563270fac77f404745fdd38c","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie konsystencji metodą opadu stożka","methodology_en":"Slump test","methodology_zh":"坍落度试验","methodology_cs":"Zkouška sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie konsystencji metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Badanie konsystencji metodą opadu stożka Čerstvý beton Zkouška sednutím ČSN EN 12350-2 Mieszanka betonowa (beton swiezy) Badanie konsystencji metoda opadu stozka Cerstvy beton Zkouska sednutim CSN EN 12350-2","search_en":"Fresh concrete Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 坍落度试验 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a70d9b8a0b8d70195d19afcc","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"2","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie konsystencji metodą stolika rozpływowego","methodology_en":"Flow table test","methodology_zh":"扩展度试验","methodology_cs":"Zkouška rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie konsystencji metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Badanie konsystencji metodą stolika rozpływowego Čerstvý beton Zkouška rozlitím ČSN EN 12350-5 Mieszanka betonowa (beton swiezy) Badanie konsystencji metoda stolika rozplywowego Cerstvy beton Zkouska rozlitim CSN EN 12350-5","search_en":"Fresh concrete Flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 扩展度试验 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3f8d06334c4c669c5a97827a","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"3","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Mieszanka betonowa (beton swiezy) Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a018cccf857707d946fb7507","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"4","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza","methodology_en":"Determination of air content","methodology_zh":"含气量测定","methodology_cs":"Stanovení obsahu vzduchu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda ciśnieniowa","technique_en":"Pressure gauge method","technique_zh":"压力计法","technique_cs":"tlakoměrná metoda","techniques":["Metoda ciśnieniowa"],"techniques_en":["Pressure gauge method"],"techniques_zh":["压力计法"],"techniques_cs":["tlakoměrná metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza\nMetoda ciśnieniowa","reference":"ČSN EN 12350-7, čl. 6","norm_bases":["ČSN EN 12350-7, čl. 6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie zawartości powietrza Metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu tlakoměrná metoda ČSN EN 12350-7, čl. 6 Mieszanka betonowa (beton swiezy) Oznaczanie zawartosci powietrza Metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu tlakomerna metoda CSN EN 12350-7, cl. 6","search_en":"Fresh concrete Determination of air content Pressure gauge method ČSN EN 12350-7, čl. 6","search_zh":"新拌混凝土 含气量测定 压力计法 ČSN EN 12350-7, čl. 6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2667fd56d79ac3a8177bc77c","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"5","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie próbek do badań","methodology_en":"Determination of compressive strength of test specimens","methodology_zh":"试件抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku zkušebních těles","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie próbek do badań","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie próbek do badań Ztvrdlý beton Stanovení pevnosti v tlaku zkušebních těles ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie probek do badan Ztvrdly beton Stanoveni pevnosti v tlaku zkusebnich teles CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength of test specimens ČSN EN 12390-3","search_zh":"硬化混凝土 试件抗压强度测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ebc4516deb5961d11df115e1","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"6","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Obliczenie z zmierzonych rzeczywistych wymiarów","technique_en":"Calculation from measured actual dimensions","technique_zh":"由实测尺寸计算","technique_cs":"výpočtem ze změřených skutečných rozměrů","techniques":["Obliczenie z zmierzonych rzeczywistych wymiarów"],"techniques_en":["Calculation from measured actual dimensions"],"techniques_zh":["由实测尺寸计算"],"techniques_cs":["výpočtem ze změřených skutečných rozměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości\nObliczenie z zmierzonych rzeczywistych wymiarów","reference":"ČSN EN 12390-7, čl. 6.1.2 b)","norm_bases":["ČSN EN 12390-7, čl. 6.1.2 b)"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Obliczenie z zmierzonych rzeczywistych wymiarów Ztvrdlý beton Stanovení objemové hmotnosti výpočtem ze změřených skutečných rozměrů ČSN EN 12390-7, čl. 6.1.2 b) Beton stwardnialy Oznaczanie gestosci Obliczenie z zmierzonych rzeczywistych wymiarow Ztvrdly beton Stanoveni objemove hmotnosti vypoctem ze zmerenych skutecnych rozmeru CSN EN 12390-7, cl. 6.1.2 b)","search_en":"Hardened concrete Determination of density Calculation from measured actual dimensions ČSN EN 12390-7, čl. 6.1.2 b)","search_zh":"硬化混凝土 密度测定 由实测尺寸计算 ČSN EN 12390-7, čl. 6.1.2 b)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29d85d2d2b38fb4e3cae01fc","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"7","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Suszenie w suszarce","technique_en":"Drying in a ventilated oven","technique_zh":"烘箱干燥法","technique_cs":"sušením v sušárně","techniques":["Suszenie w suszarce"],"techniques_en":["Drying in a ventilated oven"],"techniques_zh":["烘箱干燥法"],"techniques_cs":["sušením v sušárně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności\nSuszenie w suszarce","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności Suszenie w suszarce Kamenivo Stanovení vlhkosti sušením v sušárně ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci Suszenie w suszarce Kamenivo Stanoveni vlhkosti susenim v susarne CSN EN 1097-5","search_en":"Aggregate Determination of water content Drying in a ventilated oven ČSN EN 1097-5","search_zh":"集料 含水率测定 烘箱干燥法 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"459ee11e572ff9a75aedce5e","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"8","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Analiza sitowa","technique_en":"Sieving method","technique_zh":"筛分法","technique_cs":"sítovým rozborem","techniques":["Analiza sitowa"],"techniques_en":["Sieving method"],"techniques_zh":["筛分法"],"techniques_cs":["sítovým rozborem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia\nAnaliza sitowa","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Analiza sitowa Kamenivo Stanovení zrnitosti sítovým rozborem ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Analiza sitowa Kamenivo Stanoveni zrnitosti sitovym rozborem CSN EN 933-1","search_en":"Aggregate Determination of particle size distribution Sieving method ČSN EN 933-1","search_zh":"集料 颗粒级配测定 筛分法 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"caf27862630da27d81fe61b4","lab_id":"69ad52a4de79e566650fd3dc","country":"CZ","accr_number":"1426","accr_body":"ČIA","row_label":"9","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of resistance of cement concrete surface to water and chemical de-icing agents","methodology_zh":"水泥混凝土表面抗水及化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, metoda A","norm_bases":["ČSN 73 1326, metoda A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających Ztvrdlý beton Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek ČSN 73 1326, metoda A Beton stwardnialy Oznaczanie odpornosci powierzchni betonu cementowego na dzialanie wody i chemicznych srodkow odladzajacych Ztvrdly beton Stanoveni odolnosti povrchu cementoveho betonu proti pusobeni vody a chemickych rozmrazovacich latek CSN 73 1326, metoda A","search_en":"Hardened concrete Determination of resistance of cement concrete surface to water and chemical de-icing agents ČSN 73 1326, metoda A","search_zh":"硬化混凝土 水泥混凝土表面抗水及化学除冰剂性能测定 ČSN 73 1326, metoda A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}