{"lab":{"_id":"69ad52a4de79e566650fd3ca","accr_number":"1409","country":"CZ","accr_body":"ČIA","address":"Buštěhradská 283, 272 03 Kladno","categories":["materials"],"city":"Kladno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":14,"name":"CZ FERMET s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1409_290_2021_CS.pdf","1409_290_2021_EN.pdf"],"scope_summary":"Badania właściwości wytrzymałościowych i plastycznych materiałów metalowych oraz badania metalograficzne stali, w zakresie określonym w załączniku do świadectwa.","search_text":"cz fermet s.r.o. buštěhradská 283, 272 03 kladno 1409","status":"active","updated_at":"2026-03-08T14:52:11.559Z","valid_from":"","valid_until":"19-05-2031","website":"www.czfermet.cz","location":{"type":"Point","coordinates":[14.1036,50.1434]},"email_confidence":"high","email_mx":true,"email_source":"https://www.czfermet.cz/kontakty","map_coord":[50.150768,14.149892],"map_geo":"nominatim-street","certificate_date":"19.05.2026","certificate_no":"248/2026","certificate_replaces":"290/2021 z 27.05.2021","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania właściwości wytrzymałościowych i plastycznych materiałów metalowych oraz badania metalograficzne stali, w zakresie określonym w załączniku do świadectwa.","en":"Strength and plasticity testing of metallic materials and metallographic testing of steels to the extent as specified in the appendix to this Certificate.","zh":"金属材料强度和塑性性能检测及钢的金相检测，范围见本证书附件。","cs":"Zkoušení pevnostních a plastických vlastností kovových materiálů a metalografické zkoušky ocelí, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratoria CZ FERMET","lab_division_cs":"Laboratoře CZ FERMET","lab_division_en":"CZ FERMET Laboratories","lab_division_zh":"CZ FERMET实验室","lab_locations":[{"code":null,"name":"CZ FERMET s.r.o.","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":true,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"},{"code":null,"name":"Laboratorium Mechaniczne","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":false,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"},{"code":null,"name":"Laboratorium Metalograficzne","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":false,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"}],"lab_locations_en":[{"code":null,"name":"CZ FERMET s.r.o.","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":true,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"},{"code":null,"name":"Mechanical Laboratory","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":false,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"},{"code":null,"name":"Metallographic Laboratory","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":false,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"}],"lab_locations_zh":[{"code":null,"name":"CZ FERMET s.r.o.","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":true,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"},{"code":null,"name":"力学实验室","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":false,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"},{"code":null,"name":"金相实验室","street":"Buštěhradská 283","postal_code":"272 03","city":"Kladno","is_hq":false,"address":"Buštěhradská 283, 272 03 Kladno","site":"27203|buštěhradská283"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"ASTM","pl":"American Society for Testing and Materials (norma amerykańska)","en":"American Society for Testing and Materials (American standard)","zh":"美国材料与试验协会（美国标准）","cs":"American Society for Testing and Materials (Americká norma)"},{"abbr":"DIN","pl":"Deutsche Industrie Norm (norma niemiecka)","en":"Deutsche Industrie Norm (German standard)","zh":"德国工业标准","cs":"Deutsche Industrie Norm (Německá norma)"},{"abbr":"GOST","pl":"Gosudarstvennye Standarty (norma Federacji Rosyjskiej)","en":"Gosudarstvennye Standarty (Russian Federation standard)","zh":"俄罗斯联邦国家标准（GOST）","cs":"Gosudarstvennye Standarty (Norma Ruské federace)"},{"abbr":"SEP","pl":"Stahl – Eisen – Prüfblatt (karty badań stali i żeliwa)","en":"Stahl – Eisen – Prüfblatt (Test sheets for steels and cast irons)","zh":"钢铁检验规程（SEP，钢和铸铁检验单）","cs":"Stahl – Eisen – Prüfblatt (zkušební listy pro oceli a litiny)"},{"abbr":"PP-M-xx","pl":"Procedura robocza Laboratorium Mechanicznego","en":"Mechanical Laboratory Working Procedure","zh":"力学实验室工作程序","cs":"Pracovní postup Mechanické laboratoře"},{"abbr":"PP-G-xx","pl":"Procedura robocza Laboratorium Metalograficznego","en":"Metallographic Laboratory Working Procedure","zh":"金相实验室工作程序","cs":"Pracovní postup Metalografické laboratoře"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"0e5880336a1cb8897d1d5445cc5eef59ba29a25029e1e7ab212f13dd09fbbc17","source_pdf_url":"https://www.cai.cz/OA/pdf/248_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/248_2026_EN.pdf"},"methods":[{"_id":"78a5de948f6f00cfae192144","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"1","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Próba rozciągania w temperaturze pokojowej","methodology_en":"Tensile test at ambient temperature","methodology_zh":"室温拉伸试验","methodology_cs":"Zkouška tahem za pokojové teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba rozciągania w temperaturze pokojowej","reference":"PP-M-01 (ČSN EN ISO 6892-1; ASTM A370)","norm_bases":["PP-M-01","ČSN EN ISO 6892-1","ASTM A370"],"lab_section":"Laboratorium Mechaniczne","lab_section_en":"Mechanical Laboratory","lab_section_zh":"力学实验室","lab_section_cs":"Mechanická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Próba rozciągania w temperaturze pokojowej Kovové materiály Zkouška tahem za pokojové teploty PP-M-01 (ČSN EN ISO 6892-1; ASTM A370) Materialy metalowe Proba rozciagania w temperaturze pokojowej Kovove materialy Zkouska tahem za pokojove teploty PP-M-01 (CSN EN ISO 6892-1; ASTM A370)","search_en":"Metallic materials Tensile test at ambient temperature PP-M-01 (ČSN EN ISO 6892-1; ASTM A370)","search_zh":"金属材料 室温拉伸试验 PP-M-01 (ČSN EN ISO 6892-1; ASTM A370)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4cf62952b98ef4bb9ff0867f","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"2","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Próba rozciągania w podwyższonej temperaturze","methodology_en":"Tensile test at elevated temperature","methodology_zh":"高温拉伸试验","methodology_cs":"Zkouška tahem za zvýšené teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba rozciągania w podwyższonej temperaturze","reference":"PP-M-01 (ČSN EN ISO 6892-2)","norm_bases":["PP-M-01","ČSN EN ISO 6892-2"],"lab_section":"Laboratorium Mechaniczne","lab_section_en":"Mechanical Laboratory","lab_section_zh":"力学实验室","lab_section_cs":"Mechanická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Próba rozciągania w podwyższonej temperaturze Kovové materiály Zkouška tahem za zvýšené teploty PP-M-01 (ČSN EN ISO 6892-2) Materialy metalowe Proba rozciagania w podwyzszonej temperaturze Kovove materialy Zkouska tahem za zvysene teploty PP-M-01 (CSN EN ISO 6892-2)","search_en":"Metallic materials Tensile test at elevated temperature PP-M-01 (ČSN EN ISO 6892-2)","search_zh":"金属材料 高温拉伸试验 PP-M-01 (ČSN EN ISO 6892-2)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"65e0070ae40d6b2b2d6ea2f0","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"3","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Próba udarności (zginanie udarowe)","methodology_en":"Impact bend test","methodology_zh":"冲击弯曲试验","methodology_cs":"Zkouška rázem v ohybu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba udarności (zginanie udarowe)","reference":"PP-M-02 (ČSN EN ISO 148-1; ASTM E23)","norm_bases":["PP-M-02","ČSN EN ISO 148-1","ASTM E23"],"lab_section":"Laboratorium Mechaniczne","lab_section_en":"Mechanical Laboratory","lab_section_zh":"力学实验室","lab_section_cs":"Mechanická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Próba udarności (zginanie udarowe) Kovové materiály Zkouška rázem v ohybu PP-M-02 (ČSN EN ISO 148-1; ASTM E23) Materialy metalowe Proba udarnosci (zginanie udarowe) Kovove materialy Zkouska razem v ohybu PP-M-02 (CSN EN ISO 148-1; ASTM E23)","search_en":"Metallic materials Impact bend test PP-M-02 (ČSN EN ISO 148-1; ASTM E23)","search_zh":"金属材料 冲击弯曲试验 PP-M-02 (ČSN EN ISO 148-1; ASTM E23)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aa38c68efb1ff261a5777a5c","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"4","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Pomiar twardości sposobem Brinella","methodology_en":"Brinell hardness test","methodology_zh":"布氏硬度试验","methodology_cs":"Zkouška tvrdosti dle Brinella","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar twardości sposobem Brinella","reference":"PP-M-04 (ČSN EN ISO 6506-1)","norm_bases":["PP-M-04","ČSN EN ISO 6506-1"],"lab_section":"Laboratorium Mechaniczne","lab_section_en":"Mechanical Laboratory","lab_section_zh":"力学实验室","lab_section_cs":"Mechanická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Pomiar twardości sposobem Brinella Kovové materiály Zkouška tvrdosti dle Brinella PP-M-04 (ČSN EN ISO 6506-1) Materialy metalowe Pomiar twardosci sposobem Brinella Kovove materialy Zkouska tvrdosti dle Brinella PP-M-04 (CSN EN ISO 6506-1)","search_en":"Metallic materials Brinell hardness test PP-M-04 (ČSN EN ISO 6506-1)","search_zh":"金属材料 布氏硬度试验 PP-M-04 (ČSN EN ISO 6506-1)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ae4c7419019fcf26eae0fe7b","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"5","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Pomiar twardości sposobem Rockwella","methodology_en":"Rockwell hardness test","methodology_zh":"洛氏硬度试验","methodology_cs":"Zkouška tvrdosti dle Rockwella","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar twardości sposobem Rockwella","reference":"PP-M-05 (ČSN EN ISO 6508-1)","norm_bases":["PP-M-05","ČSN EN ISO 6508-1"],"lab_section":"Laboratorium Mechaniczne","lab_section_en":"Mechanical Laboratory","lab_section_zh":"力学实验室","lab_section_cs":"Mechanická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Pomiar twardości sposobem Rockwella Kovové materiály Zkouška tvrdosti dle Rockwella PP-M-05 (ČSN EN ISO 6508-1) Materialy metalowe Pomiar twardosci sposobem Rockwella Kovove materialy Zkouska tvrdosti dle Rockwella PP-M-05 (CSN EN ISO 6508-1)","search_en":"Metallic materials Rockwell hardness test PP-M-05 (ČSN EN ISO 6508-1)","search_zh":"金属材料 洛氏硬度试验 PP-M-05 (ČSN EN ISO 6508-1)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8cc55b931f67ee681ebfaae5","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"6","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Pomiar twardości sposobem Vickersa","methodology_en":"Vickers hardness test","methodology_zh":"维氏硬度试验","methodology_cs":"Zkouška tvrdosti dle Vickerse","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar twardości sposobem Vickersa","reference":"PP-M-06 ČSN EN ISO 6507-1)","norm_bases":["PP-M-06","ČSN EN ISO 6507-1"],"lab_section":"Laboratorium Mechaniczne","lab_section_en":"Mechanical Laboratory","lab_section_zh":"力学实验室","lab_section_cs":"Mechanická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Pomiar twardości sposobem Vickersa Kovové materiály Zkouška tvrdosti dle Vickerse PP-M-06 ČSN EN ISO 6507-1) Materialy metalowe Pomiar twardosci sposobem Vickersa Kovove materialy Zkouska tvrdosti dle Vickerse PP-M-06 CSN EN ISO 6507-1)","search_en":"Metallic materials Vickers hardness test PP-M-06 ČSN EN ISO 6507-1)","search_zh":"金属材料 维氏硬度试验 PP-M-06 ČSN EN ISO 6507-1)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"90a11002479d60fbf1100cfc","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"7","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Próba zginania","methodology_en":"Bend test","methodology_zh":"弯曲试验","methodology_cs":"Zkouška ohybem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba zginania","reference":"PP-M-03 (ČSN EN ISO 7438; ČSN EN ISO 5173)","norm_bases":["PP-M-03","ČSN EN ISO 7438","ČSN EN ISO 5173"],"lab_section":"Laboratorium Mechaniczne","lab_section_en":"Mechanical Laboratory","lab_section_zh":"力学实验室","lab_section_cs":"Mechanická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Próba zginania Kovové materiály Zkouška ohybem PP-M-03 (ČSN EN ISO 7438; ČSN EN ISO 5173) Materialy metalowe Proba zginania Kovove materialy Zkouska ohybem PP-M-03 (CSN EN ISO 7438; CSN EN ISO 5173)","search_en":"Metallic materials Bend test PP-M-03 (ČSN EN ISO 7438; ČSN EN ISO 5173)","search_zh":"金属材料 弯曲试验 PP-M-03 (ČSN EN ISO 7438; ČSN EN ISO 5173)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4292c1b64d75e6c4ef5551cd","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"1","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Metalograficzne oznaczanie wtrąceń niemetalicznych","methodology_en":"Metallographic determination of non-Metallic intrusions","methodology_zh":"非金属夹杂物金相测定","methodology_cs":"Metalografické stanovení nekovových vměstků","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Metalograficzne oznaczanie wtrąceń niemetalicznych","reference":"PP-G-15 (ASTM E45; DIN 50602; ČSN ISO 4967; GOST 1778; SEP 1572)","norm_bases":["PP-G-15","ASTM E45","DIN 50602","ČSN ISO 4967","GOST 1778","SEP 1572"],"lab_section":"Laboratorium Metalograficzne","lab_section_en":"Metallographic Laboratory","lab_section_zh":"金相实验室","lab_section_cs":"Metalografická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Metalograficzne oznaczanie wtrąceń niemetalicznych Oceli Metalografické stanovení nekovových vměstků PP-G-15 (ASTM E45; DIN 50602; ČSN ISO 4967; GOST 1778; SEP 1572) Stale Metalograficzne oznaczanie wtracen niemetalicznych Oceli Metalograficke stanoveni nekovovych vmestku PP-G-15 (ASTM E45; DIN 50602; CSN ISO 4967; GOST 1778; SEP 1572)","search_en":"Steel Metallographic determination of non-Metallic intrusions PP-G-15 (ASTM E45; DIN 50602; ČSN ISO 4967; GOST 1778; SEP 1572)","search_zh":"钢 非金属夹杂物金相测定 PP-G-15 (ASTM E45; DIN 50602; ČSN ISO 4967; GOST 1778; SEP 1572)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f5bcf4187af5f4396069db2b","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"2","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Oznaczanie wielkości ziarna wraz z przygotowaniem próbki","methodology_en":"Determination of apparent grain size including sample preparation","methodology_zh":"晶粒度测定（含试样制备）","methodology_cs":"Stanovení velikosti zrna včetně přípravy vzorku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielkości ziarna wraz z przygotowaniem próbki","reference":"PP-G-13 (ASTM E112; DIN 50601; ČSN EN ISO 643) PP-G-14 (ASTM E112; DIN 50601; ČSN EN ISO 643)","norm_bases":["PP-G-13","PP-G-14","ASTM E112","DIN 50601","ČSN EN ISO 643"],"lab_section":"Laboratorium Metalograficzne","lab_section_en":"Metallographic Laboratory","lab_section_zh":"金相实验室","lab_section_cs":"Metalografická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Oznaczanie wielkości ziarna wraz z przygotowaniem próbki Oceli Stanovení velikosti zrna včetně přípravy vzorku PP-G-13 (ASTM E112; DIN 50601; ČSN EN ISO 643) PP-G-14 (ASTM E112; DIN 50601; ČSN EN ISO 643) Stale Oznaczanie wielkosci ziarna wraz z przygotowaniem probki Oceli Stanoveni velikosti zrna vcetne pripravy vzorku PP-G-13 (ASTM E112; DIN 50601; CSN EN ISO 643) PP-G-14 (ASTM E112; DIN 50601; CSN EN ISO 643)","search_en":"Steel Determination of apparent grain size including sample preparation PP-G-13 (ASTM E112; DIN 50601; ČSN EN ISO 643) PP-G-14 (ASTM E112; DIN 50601; ČSN EN ISO 643)","search_zh":"钢 晶粒度测定（含试样制备） PP-G-13 (ASTM E112; DIN 50601; ČSN EN ISO 643) PP-G-14 (ASTM E112; DIN 50601; ČSN EN ISO 643)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4304b2c2e91e6b7cfa0b2833","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"3","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Ocena mikrostruktury","methodology_en":"Evaluation of microstructure","methodology_zh":"显微组织评定","methodology_cs":"Vyhodnocení mikrostruktury","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ocena mikrostruktury","reference":"ČSN 42 0469; SEP 1520; SEP 1614","norm_bases":["ČSN 42 0469","SEP 1520","SEP 1614"],"lab_section":"Laboratorium Metalograficzne","lab_section_en":"Metallographic Laboratory","lab_section_zh":"金相实验室","lab_section_cs":"Metalografická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Ocena mikrostruktury Oceli Vyhodnocení mikrostruktury ČSN 42 0469; SEP 1520; SEP 1614 Stale Ocena mikrostruktury Oceli Vyhodnoceni mikrostruktury CSN 42 0469; SEP 1520; SEP 1614","search_en":"Steel Evaluation of microstructure ČSN 42 0469; SEP 1520; SEP 1614","search_zh":"钢 显微组织评定 ČSN 42 0469; SEP 1520; SEP 1614","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f7cefe5566c668be5c11aa93","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"4","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Oznaczanie głębokości odwęglenia","methodology_en":"Determination of depth of decarburization","methodology_zh":"脱碳层深度测定","methodology_cs":"Stanovení hloubky oduhličení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości odwęglenia","reference":"PP-G-12 (ČSN EN ISO 3887; DIN 50192; ASTM E1077)","norm_bases":["PP-G-12","ČSN EN ISO 3887","DIN 50192","ASTM E1077"],"lab_section":"Laboratorium Metalograficzne","lab_section_en":"Metallographic Laboratory","lab_section_zh":"金相实验室","lab_section_cs":"Metalografická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Oznaczanie głębokości odwęglenia Oceli Stanovení hloubky oduhličení PP-G-12 (ČSN EN ISO 3887; DIN 50192; ASTM E1077) Stale Oznaczanie glebokosci odweglenia Oceli Stanoveni hloubky oduhliceni PP-G-12 (CSN EN ISO 3887; DIN 50192; ASTM E1077)","search_en":"Steel Determination of depth of decarburization PP-G-12 (ČSN EN ISO 3887; DIN 50192; ASTM E1077)","search_zh":"钢 脱碳层深度测定 PP-G-12 (ČSN EN ISO 3887; DIN 50192; ASTM E1077)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc829c3459f58d70ed4c54a6","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"5","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Badanie odporności na korozję międzykrystaliczną","methodology_en":"Test of resistance to intergranular corrosion","methodology_zh":"晶间腐蚀试验","methodology_cs":"Zkouška odolnosti proti mezikrystalové korozi","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na korozję międzykrystaliczną","reference":"PP-G-17 (GOST 6032; ČSN EN ISO 3651-2)","norm_bases":["PP-G-17","GOST 6032","ČSN EN ISO 3651-2"],"lab_section":"Laboratorium Metalograficzne","lab_section_en":"Metallographic Laboratory","lab_section_zh":"金相实验室","lab_section_cs":"Metalografická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Badanie odporności na korozję międzykrystaliczną Oceli Zkouška odolnosti proti mezikrystalové korozi PP-G-17 (GOST 6032; ČSN EN ISO 3651-2) Stale Badanie odpornosci na korozje miedzykrystaliczna Oceli Zkouska odolnosti proti mezikrystalove korozi PP-G-17 (GOST 6032; CSN EN ISO 3651-2)","search_en":"Steel Test of resistance to intergranular corrosion PP-G-17 (GOST 6032; ČSN EN ISO 3651-2)","search_zh":"钢 晶间腐蚀试验 PP-G-17 (GOST 6032; ČSN EN ISO 3651-2)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4b899be9a7af699f35b60b31","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"6","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Badania makroskopowe i mikroskopowe złączy spawanych","methodology_en":"Macroscopic and microscopic examination of welds","methodology_zh":"焊缝宏观和微观检验","methodology_cs":"Makroskopická a mikroskopická kontrola svarů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania makroskopowe i mikroskopowe złączy spawanych","reference":"ČSN EN ISO 17639 ČSN EN ISO 6520-1","norm_bases":["ČSN EN ISO 17639","ČSN EN ISO 6520-1"],"lab_section":"Laboratorium Metalograficzne","lab_section_en":"Metallographic Laboratory","lab_section_zh":"金相实验室","lab_section_cs":"Metalografická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Badania makroskopowe i mikroskopowe złączy spawanych Oceli Makroskopická a mikroskopická kontrola svarů ČSN EN ISO 17639 ČSN EN ISO 6520-1 Stale Badania makroskopowe i mikroskopowe zlaczy spawanych Oceli Makroskopicka a mikroskopicka kontrola svaru CSN EN ISO 17639 CSN EN ISO 6520-1","search_en":"Steel Macroscopic and microscopic examination of welds ČSN EN ISO 17639 ČSN EN ISO 6520-1","search_zh":"钢 焊缝宏观和微观检验 ČSN EN ISO 17639 ČSN EN ISO 6520-1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7d685004b7b2775344966ca5","lab_id":"69ad52a4de79e566650fd3ca","country":"CZ","accr_number":"1409","accr_body":"ČIA","row_label":"7","test_object":"Stale","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Oceli","methodology":"Badanie hartowności metodą chłodzenia od czoła (próba Jominy'ego)","methodology_en":"Hardenability test by end quenching (Jominy test)","methodology_zh":"端淬法淬透性试验（Jominy试验）","methodology_cs":"Čelní zkouška prokalitelnosti podle Jominyho","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie hartowności metodą chłodzenia od czoła (próba Jominy'ego)","reference":"PP-M-07 (ČSN EN ISO 642; ASTM A255) PP-G-11 (ČSN EN ISO 642; ASTM A255)","norm_bases":["PP-M-07","PP-G-11","ČSN EN ISO 642","ASTM A255"],"lab_section":"Laboratorium Metalograficzne","lab_section_en":"Metallographic Laboratory","lab_section_zh":"金相实验室","lab_section_cs":"Metalografická laboratoř","lab_address":"Buštěhradská 283, 272 03 Kladno","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stale Badanie hartowności metodą chłodzenia od czoła (próba Jominy'ego) Oceli Čelní zkouška prokalitelnosti podle Jominyho PP-M-07 (ČSN EN ISO 642; ASTM A255) PP-G-11 (ČSN EN ISO 642; ASTM A255) Stale Badanie hartownosci metoda chlodzenia od czola (proba Jominy'ego) Oceli Celni zkouska prokalitelnosti podle Jominyho PP-M-07 (CSN EN ISO 642; ASTM A255) PP-G-11 (CSN EN ISO 642; ASTM A255)","search_en":"Steel Hardenability test by end quenching (Jominy test) PP-M-07 (ČSN EN ISO 642; ASTM A255) PP-G-11 (ČSN EN ISO 642; ASTM A255)","search_zh":"钢 端淬法淬透性试验（Jominy试验） PP-M-07 (ČSN EN ISO 642; ASTM A255) PP-G-11 (ČSN EN ISO 642; ASTM A255)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}