{"lab":{"_id":"69ad52a4de79e566650fd3c6","accr_number":"1406","country":"CZ","accr_body":"ČIA","address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","categories":["water","environment","microbiology"],"city":"Velké Meziříčí","imported_at":"2026-03-08T10:42:44.590Z","methods_count":87,"name":"ENVIRO – EKOANALYTIKA, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1406_127_2025_CS.pdf","1406_127_2025_EN.pdf"],"scope_summary":"Analizy chemiczne i mikrobiologiczne wód i wyciągów wodnych, gruntów, odpadów, osadów, osadów dennych, gleb rolnych i leśnych, żywności, pasz, materiału roślinnego i nawozów, pobieranie próbek, w tym samodzielne, w zakresie określonym w załączniku do świadectwa.","search_text":"enviro – ekoanalytika, s.r.o. nad kunšovcem 1405/2, 594 01 velké meziříčí 1406","status":"active","updated_at":"2026-03-08T14:52:11.558Z","valid_from":"","valid_until":"05-05-2031","website":"www.enviroeko.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.enviroeko.cz","map_coord":[49.350415,16.025508],"map_geo":"nominatim-street","certificate_date":"05.05.2026","certificate_no":"225/2026","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analizy chemiczne i mikrobiologiczne wód i wyciągów wodnych, gruntów, odpadów, osadów, osadów dennych, gleb rolnych i leśnych, żywności, pasz, materiału roślinnego i nawozów, pobieranie próbek, w tym samodzielne, w zakresie określonym w załączniku do świadectwa.","en":"Chemical and microbiological analyses of water and aqueous leachates, soils, waste, sludge, sediments, agricultural and forest soils, foods, feeds, plant materials and fertilisers, sampling including standalone sampling, as specified in the appendix to this certificate.","zh":"水和水浸出液、土壤、废物、污泥、沉积物、农业和林业土壤、食品、饲料、植物材料和肥料的化学和微生物分析，采样（包括独立采样），范围见本证书附件。","cs":"Chemické a mikrobiologické analýzy vod a vodných výluhů, zemin, odpadů, kalů, sedimentů, zemědělských a lesních půd, potravin, krmiv, rostlinných materiálů a hnojiv, vzorkování včetně samostatného vzorkování, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","lab_locations":[{"code":null,"name":"ENVIRO – EKOANALYTIKA, s.r.o.","street":"Nad Kunšovcem 1405/2","postal_code":"594 01","city":"Velké Meziříčí","is_hq":true,"address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","site":"59401|nadkunšovcem1405/2"},{"code":null,"name":"Laboratorium Metod Podstawowych","street":"Třebíčská 1540","postal_code":"594 01","city":"Velké Meziříčí","is_hq":false,"address":"Třebíčská 1540, 594 01 Velké Meziříčí","site":"59401|třebíčská1540"},{"code":null,"name":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","street":"Nad Kunšovcem 1405/2","postal_code":"594 01","city":"Velké Meziříčí","is_hq":false,"address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","site":"59401|nadkunšovcem1405/2"}],"lab_locations_en":[{"code":null,"name":"ENVIRO – EKOANALYTIKA, s.r.o.","street":"Nad Kunšovcem 1405/2","postal_code":"594 01","city":"Velké Meziříčí","is_hq":true,"address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","site":"59401|nadkunšovcem1405/2"},{"code":null,"name":"Laboratory of Basic Methods","street":"Třebíčská 1540","postal_code":"594 01","city":"Velké Meziříčí","is_hq":false,"address":"Třebíčská 1540, 594 01 Velké Meziříčí","site":"59401|třebíčská1540"},{"code":null,"name":"Laboratory of Special Methods and Sampling Section","street":"Nad Kunšovcem 1405/2","postal_code":"594 01","city":"Velké Meziříčí","is_hq":false,"address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","site":"59401|nadkunšovcem1405/2"}],"lab_locations_zh":[{"code":null,"name":"ENVIRO – EKOANALYTIKA, s.r.o.","street":"Nad Kunšovcem 1405/2","postal_code":"594 01","city":"Velké Meziříčí","is_hq":true,"address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","site":"59401|nadkunšovcem1405/2"},{"code":null,"name":"基础方法实验室","street":"Třebíčská 1540","postal_code":"594 01","city":"Velké Meziříčí","is_hq":false,"address":"Třebíčská 1540, 594 01 Velké Meziříčí","site":"59401|třebíčská1540"},{"code":null,"name":"专项方法实验室和采样组","street":"Nad Kunšovcem 1405/2","postal_code":"594 01","city":"Velké Meziříčí","is_hq":false,"address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","site":"59401|nadkunšovcem1405/2"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"DIN","pl":"niemiecka norma krajowa (Deutsches Institut für Normung)","en":"German national standard (Deutsches Institut für Normung)","zh":"德国国家标准（德国标准化学会）","cs":"německá národní norma (Deutches Institut für Normung)"},{"abbr":"ECD","pl":"detektor wychwytu elektronów","en":"electron capture detector","zh":"电子捕获检测器","cs":"detektor elektronového záchytu"},{"abbr":"FID","pl":"detektor płomieniowo-jonizacyjny","en":"flame ionisation detector","zh":"火焰离子化检测器","cs":"plameno-ionizační detektor"},{"abbr":"HPLC","pl":"wysokosprawna chromatografia cieczowa","en":"high-performance liquid chromatography","zh":"高效液相色谱","cs":"vysokoúčinná kapalinová chromatografie"},{"abbr":"ICP-MS","pl":"spektrometria mas z plazmą wzbudzoną indukcyjnie","en":"inductively coupled plasma mass spectrometry","zh":"电感耦合等离子体质谱","cs":"hmotnostní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"JPP ÚKZÚZ","pl":"ujednolicone procedury robocze Centralnego Instytutu Kontroli i Badań Rolniczych (ÚKZÚZ)","en":"unified working procedures of the Central Institute for Supervising and Testing in Agriculture (ÚKZÚZ)","zh":"捷克中央农业监督检测研究所统一工作程序","cs":"jednotné pracovní postupy Ústředního kontrolního a zkušebního ústavu zemědělského"},{"abbr":"MZ","pl":"Ministerstwo Zdrowia (Czechy)","en":"Ministry of Health (Czech Republic)","zh":"捷克卫生部","cs":"Ministerstvo zdravotnictví"},{"abbr":"MZe ČR","pl":"Ministerstwo Rolnictwa Republiki Czeskiej","en":"Ministry of Agriculture of the Czech Republic","zh":"捷克农业部","cs":"Ministerstvo zemědělství České republiky"},{"abbr":"MŽP ČR","pl":"Ministerstwo Środowiska Republiki Czeskiej","en":"Ministry of the Environment of the Czech Republic","zh":"捷克环境部","cs":"Ministerstvo životního prostředí České republiky"},{"abbr":"SOP","pl":"standardowa procedura operacyjna opracowana na podstawie obowiązujących przepisów","en":"standard operating procedure based on valid legislation","zh":"依据现行法规编制的标准操作程序","cs":"standardní operační postup vypracovaný na základě platné legislativy"},{"abbr":"SOP VZ","pl":"standardowa procedura operacyjna pobierania próbek opracowana na podstawie obowiązujących przepisów","en":"standard operating procedure for sampling based on valid legislation","zh":"依据现行法规编制的采样标准操作程序","cs":"standardní operační postup pro vzorkování vypracovaný na základě platné legislativy"},{"abbr":"TNV","pl":"branżowa norma techniczna gospodarki wodnej","en":"sectoral technical standard for water management","zh":"水务行业技术标准","cs":"odvětvová technická norma vodního hospodářství"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立进行采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"28e7b8c7a8aa1edbacc1f88c68abc7b934f713e498276a30e600a6c09e715426","source_pdf_url":"https://www.cai.cz/OA/pdf/225_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"5c065254a32d474d269ce284","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"1","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP 1 (ČSN ISO 10523)","norm_bases":["SOP 1","ČSN ISO 10523"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie pH metodą potencjometryczną Vody, voda odpadní, výluhy Stanovení pH potenciometricky SOP 1 (ČSN ISO 10523) Wody, scieki, wyciagi Oznaczanie pH metoda potencjometryczna Vody, voda odpadni, vyluhy Stanoveni pH potenciometricky SOP 1 (CSN ISO 10523)","search_en":"Waters, waste water, leachates Determination of pH by potentiometry SOP 1 (ČSN ISO 10523)","search_zh":"水、废水、浸出液 电位法测定pH SOP 1 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cda9f590295933ff79c7a9ef","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"2","test_object":"Wody, ścieki, wyciągi z odpadów","test_object_en":"Waters, waste water, waste leachates","test_object_zh":"水、废水、废物浸出液","test_object_cs":"Vody, voda odpadní, výluhy z odpadů","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"SOP 9 (ČSN EN 27888)","norm_bases":["SOP 9","ČSN EN 27888"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi z odpadów Oznaczanie przewodności elektrycznej właściwej Vody, voda odpadní, výluhy z odpadů Stanovení elektrické konduktivity SOP 9 (ČSN EN 27888) Wody, scieki, wyciagi z odpadow Oznaczanie przewodnosci elektrycznej wlasciwej Vody, voda odpadni, vyluhy z odpadu Stanoveni elektricke konduktivity SOP 9 (CSN EN 27888)","search_en":"Waters, waste water, waste leachates Determination of electrical conductivity SOP 9 (ČSN EN 27888)","search_zh":"水、废水、废物浸出液 电导率测定 SOP 9 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"65b817635037d00209dd7c06","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"3","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie tlenu rozpuszczonego (O2) sondą membranową","methodology_en":"Determination of dissolved oxygen (O2) with a membrane probe","methodology_zh":"膜电极法测定溶解氧（O2）","methodology_cs":"Stanovení rozpuštěného kyslíku (O2) membránovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego (O2) sondą membranową","reference":"SOP 6 (ČSN EN ISO 5814)","norm_bases":["SOP 6","ČSN EN ISO 5814"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie tlenu rozpuszczonego (O2) sondą membranową Vody, voda odpadní Stanovení rozpuštěného kyslíku (O2) membránovou sondou SOP 6 (ČSN EN ISO 5814) Wody, scieki Oznaczanie tlenu rozpuszczonego (O2) sonda membranowa Vody, voda odpadni Stanoveni rozpusteneho kysliku (O2) membranovou sondou SOP 6 (CSN EN ISO 5814)","search_en":"Waters, waste water Determination of dissolved oxygen (O2) with a membrane probe SOP 6 (ČSN EN ISO 5814)","search_zh":"水、废水 膜电极法测定溶解氧（O2） SOP 6 (ČSN EN ISO 5814)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4cf9cc65077609fadfb54927","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"4","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) elektrodą tlenową","methodology_en":"Determination of biochemical oxygen demand (BOD5) with an oxygen electrode","methodology_zh":"氧电极法测定生化需氧量（BOD5）","methodology_cs":"Stanovení biochemické spotřeby kyslíku (BSK5) kyslíkovou elektrodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) elektrodą tlenową","reference":"SOP 3 (ČSN EN 1899-2; ČSN EN ISO 5815-1)","norm_bases":["SOP 3","ČSN EN 1899-2","ČSN EN ISO 5815-1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) elektrodą tlenową Vody, voda odpadní Stanovení biochemické spotřeby kyslíku (BSK5) kyslíkovou elektrodou SOP 3 (ČSN EN 1899-2; ČSN EN ISO 5815-1) Wody, scieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) elektroda tlenowa Vody, voda odpadni Stanoveni biochemicke spotreby kysliku (BSK5) kyslikovou elektrodou SOP 3 (CSN EN 1899-2; CSN EN ISO 5815-1)","search_en":"Waters, waste water Determination of biochemical oxygen demand (BOD5) with an oxygen electrode SOP 3 (ČSN EN 1899-2; ČSN EN ISO 5815-1)","search_zh":"水、废水 氧电极法测定生化需氧量（BOD5） SOP 3 (ČSN EN 1899-2; ČSN EN ISO 5815-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0be62eaecee33f704fce5179","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"5","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) metodą spektrofotometryczną komercyjnym zestawem analitycznym","methodology_en":"Determination of biochemical oxygen demand (BOD5) by spectrophotometry using a commercial analytical kit","methodology_zh":"使用商品化分析试剂盒分光光度法测定生化需氧量（BOD5）","methodology_cs":"Stanovení biochemické spotřeby kyslíku (BSK5) spektrofotometricky analytickou komerční soupravou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) metodą spektrofotometryczną komercyjnym zestawem analitycznym","reference":"SOP 3A (návod firmy HACH)","norm_bases":["SOP 3A","návod firmy HACH"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) metodą spektrofotometryczną komercyjnym zestawem analitycznym Vody, voda odpadní Stanovení biochemické spotřeby kyslíku (BSK5) spektrofotometricky analytickou komerční soupravou SOP 3A (návod firmy HACH) Wody, scieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) metoda spektrofotometryczna komercyjnym zestawem analitycznym Vody, voda odpadni Stanoveni biochemicke spotreby kysliku (BSK5) spektrofotometricky analytickou komercni soupravou SOP 3A (navod firmy HACH)","search_en":"Waters, waste water Determination of biochemical oxygen demand (BOD5) by spectrophotometry using a commercial analytical kit SOP 3A (návod firmy HACH)","search_zh":"水、废水 使用商品化分析试剂盒分光光度法测定生化需氧量（BOD5） SOP 3A (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"141ccb1ef1ca69cfccb8bad6","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"6","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metodą miareczkową po utlenieniu","methodology_en":"Determination of chemical oxygen demand by potassium dichromate (CODCr) by titration after oxidation","methodology_zh":"氧化后滴定法测定重铬酸钾化学需氧量（CODCr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) odměrnou metodou po oxidaci","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metodą miareczkową po utlenieniu","reference":"SOP 4 (ČSN ISO 6060)","norm_bases":["SOP 4","ČSN ISO 6060"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metodą miareczkową po utlenieniu Vody, voda odpadní, výluhy Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) odměrnou metodou po oxidaci SOP 4 (ČSN ISO 6060) Wody, scieki, wyciagi Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metoda miareczkowa po utlenieniu Vody, voda odpadni, vyluhy Stanoveni chemicke spotreby kysliku dichromanem draselnym (CHSKCr) odmernou metodou po oxidaci SOP 4 (CSN ISO 6060)","search_en":"Waters, waste water, leachates Determination of chemical oxygen demand by potassium dichromate (CODCr) by titration after oxidation SOP 4 (ČSN ISO 6060)","search_zh":"水、废水、浸出液 氧化后滴定法测定重铬酸钾化学需氧量（CODCr） SOP 4 (ČSN ISO 6060)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bdf224cb3fa53f22371d0526","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"7","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metodą spektrofotometryczną komercyjnym zestawem analitycznym","methodology_en":"Determination of chemical oxygen demand by potassium dichromate (CODCr) by spectrophotometry using a commercial analytical kit","methodology_zh":"使用商品化分析试剂盒分光光度法测定重铬酸钾化学需氧量（CODCr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) spektrofotometricky analytickou komerční soupravou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metodą spektrofotometryczną komercyjnym zestawem analitycznym","reference":"SOP 4A (návod firmy HACH)","norm_bases":["SOP 4A","návod firmy HACH"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metodą spektrofotometryczną komercyjnym zestawem analitycznym Vody, voda odpadní, výluhy Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) spektrofotometricky analytickou komerční soupravou SOP 4A (návod firmy HACH) Wody, scieki, wyciagi Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZT-Cr) metoda spektrofotometryczna komercyjnym zestawem analitycznym Vody, voda odpadni, vyluhy Stanoveni chemicke spotreby kysliku dichromanem draselnym (CHSKCr) spektrofotometricky analytickou komercni soupravou SOP 4A (navod firmy HACH)","search_en":"Waters, waste water, leachates Determination of chemical oxygen demand by potassium dichromate (CODCr) by spectrophotometry using a commercial analytical kit SOP 4A (návod firmy HACH)","search_zh":"水、废水、浸出液 使用商品化分析试剂盒分光光度法测定重铬酸钾化学需氧量（CODCr） SOP 4A (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19569e6bd52394dc993aa836","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"8","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZT-Mn) metodą miareczkową","methodology_en":"Determination of chemical oxygen demand by potassium permanganate (CODMn) by titration","methodology_zh":"滴定法测定高锰酸钾化学需氧量（CODMn）","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem draselným (CHSKMn) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZT-Mn) metodą miareczkową","reference":"SOP 5 (ČSN EN ISO 8467)","norm_bases":["SOP 5","ČSN EN ISO 8467"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZT-Mn) metodą miareczkową Vody Stanovení chemické spotřeby kyslíku manganistanem draselným (CHSKMn) titračně SOP 5 (ČSN EN ISO 8467) Wody Oznaczanie chemicznego zapotrzebowania tlenu nadmanganianem potasu (ChZT-Mn) metoda miareczkowa Vody Stanoveni chemicke spotreby kysliku manganistanem draselnym (CHSKMn) titracne SOP 5 (CSN EN ISO 8467)","search_en":"Waters Determination of chemical oxygen demand by potassium permanganate (CODMn) by titration SOP 5 (ČSN EN ISO 8467)","search_zh":"水 滴定法测定高锰酸钾化学需氧量（CODMn） SOP 5 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7e2d29572b9b19044403c1c3","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"9","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie zawiesiny ogólnej (NL) metodą wagową","methodology_en":"Determination of suspended solids (SS) by gravimetry","methodology_zh":"重量法测定悬浮物（SS）","methodology_cs":"Stanovení nerozpuštěných látek (NL) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny ogólnej (NL) metodą wagową","reference":"SOP 7 (ČSN EN 872)","norm_bases":["SOP 7","ČSN EN 872"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie zawiesiny ogólnej (NL) metodą wagową Vody, voda odpadní Stanovení nerozpuštěných látek (NL) gravimetricky SOP 7 (ČSN EN 872) Wody, scieki Oznaczanie zawiesiny ogolnej (NL) metoda wagowa Vody, voda odpadni Stanoveni nerozpustenych latek (NL) gravimetricky SOP 7 (CSN EN 872)","search_en":"Waters, waste water Determination of suspended solids (SS) by gravimetry SOP 7 (ČSN EN 872)","search_zh":"水、废水 重量法测定悬浮物（SS） SOP 7 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b43501ac9a30f9cc52379e4","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"10","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie substancji rozpuszczonych (RL) metodą wagową","methodology_en":"Determination of dissolved solids (DS) by gravimetry","methodology_zh":"重量法测定溶解性固体（DS）","methodology_cs":"Stanovení rozpuštěných látek (RL) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych (RL) metodą wagową","reference":"SOP 8 (ČSN 75 7346)","norm_bases":["SOP 8","ČSN 75 7346"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie substancji rozpuszczonych (RL) metodą wagową Vody, voda odpadní, výluhy Stanovení rozpuštěných látek (RL) gravimetricky SOP 8 (ČSN 75 7346) Wody, scieki, wyciagi Oznaczanie substancji rozpuszczonych (RL) metoda wagowa Vody, voda odpadni, vyluhy Stanoveni rozpustenych latek (RL) gravimetricky SOP 8 (CSN 75 7346)","search_en":"Waters, waste water, leachates Determination of dissolved solids (DS) by gravimetry SOP 8 (ČSN 75 7346)","search_zh":"水、废水、浸出液 重量法测定溶解性固体（DS） SOP 8 (ČSN 75 7346)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61c15264a699015fd8b6ed3c","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"11","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową","methodology_en":"Determination of dissolved inorganic salts (DIS) by gravimetry","methodology_zh":"重量法测定溶解性无机盐（DIS）","methodology_cs":"Stanovení rozpuštěných anorganických solí (RAS) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową","reference":"SOP 53 (ČSN 75 7347)","norm_bases":["SOP 53","ČSN 75 7347"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową Vody, voda odpadní Stanovení rozpuštěných anorganických solí (RAS) gravimetricky SOP 53 (ČSN 75 7347) Wody, scieki Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metoda wagowa Vody, voda odpadni Stanoveni rozpustenych anorganickych soli (RAS) gravimetricky SOP 53 (CSN 75 7347)","search_en":"Waters, waste water Determination of dissolved inorganic salts (DIS) by gravimetry SOP 53 (ČSN 75 7347)","search_zh":"水、废水 重量法测定溶解性无机盐（DIS） SOP 53 (ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"754f5bef868c40c74518a9c7","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"12","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie kwasowej pojemności neutralizacji (KNK8,3, KNK4,5) metodą miareczkową","methodology_en":"Determination of acid neutralising capacity (ANC8.3, ANC4.5) by titration","methodology_zh":"滴定法测定酸中和容量（ANC8.3、ANC4.5）","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK8,3, KNK4,5) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasowej pojemności neutralizacji (KNK8,3, KNK4,5) metodą miareczkową","reference":"SOP 10 (ČSN EN ISO 9963-1)","norm_bases":["SOP 10","ČSN EN ISO 9963-1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie kwasowej pojemności neutralizacji (KNK8,3, KNK4,5) metodą miareczkową Vody, voda odpadní Stanovení kyselinové neutralizační kapacity (KNK8,3, KNK4,5) titračně SOP 10 (ČSN EN ISO 9963-1) Wody, scieki Oznaczanie kwasowej pojemnosci neutralizacji (KNK8,3, KNK4,5) metoda miareczkowa Vody, voda odpadni Stanoveni kyselinove neutralizacni kapacity (KNK8,3, KNK4,5) titracne SOP 10 (CSN EN ISO 9963-1)","search_en":"Waters, waste water Determination of acid neutralising capacity (ANC8.3, ANC4.5) by titration SOP 10 (ČSN EN ISO 9963-1)","search_zh":"水、废水 滴定法测定酸中和容量（ANC8.3、ANC4.5） SOP 10 (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e2d0fb19c19889fa74e84521","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"13","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie zasadowej pojemności neutralizacji (ZNK8,3, ZNK4,5) metodą miareczkową","methodology_en":"Determination of base neutralising capacity (BNC8.3, BNC4.5) by titration","methodology_zh":"滴定法测定碱中和容量（BNC8.3、BNC4.5）","methodology_cs":"Stanovení zásadové neutralizační kapacity (ZNK8,3, ZNK4,5) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zasadowej pojemności neutralizacji (ZNK8,3, ZNK4,5) metodą miareczkową","reference":"SOP 11 (ČSN 75 7372)","norm_bases":["SOP 11","ČSN 75 7372"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie zasadowej pojemności neutralizacji (ZNK8,3, ZNK4,5) metodą miareczkową Vody Stanovení zásadové neutralizační kapacity (ZNK8,3, ZNK4,5) titračně SOP 11 (ČSN 75 7372) Wody Oznaczanie zasadowej pojemnosci neutralizacji (ZNK8,3, ZNK4,5) metoda miareczkowa Vody Stanoveni zasadove neutralizacni kapacity (ZNK8,3, ZNK4,5) titracne SOP 11 (CSN 75 7372)","search_en":"Waters Determination of base neutralising capacity (BNC8.3, BNC4.5) by titration SOP 11 (ČSN 75 7372)","search_zh":"水 滴定法测定碱中和容量（BNC8.3、BNC4.5） SOP 11 (ČSN 75 7372)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5311c5d19e9858841e22e735","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"14","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie barwy metodą spektrofotometryczną","methodology_en":"Determination of colour by spectrophotometry","methodology_zh":"分光光度法测定色度","methodology_cs":"Stanovení barvy spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą spektrofotometryczną","reference":"SOP 51 (ČSN EN ISO 7887)","norm_bases":["SOP 51","ČSN EN ISO 7887"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie barwy metodą spektrofotometryczną Vody Stanovení barvy spektrofotometricky SOP 51 (ČSN EN ISO 7887) Wody Oznaczanie barwy metoda spektrofotometryczna Vody Stanoveni barvy spektrofotometricky SOP 51 (CSN EN ISO 7887)","search_en":"Waters Determination of colour by spectrophotometry SOP 51 (ČSN EN ISO 7887)","search_zh":"水 分光光度法测定色度 SOP 51 (ČSN EN ISO 7887)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14ab9778337b55a44c1555cd","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"15","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie mętności metodą turbidymetryczną","methodology_en":"Determination of turbidity by turbidimetry","methodology_zh":"比浊法测定浊度","methodology_cs":"Stanovení zákalu turbidimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą turbidymetryczną","reference":"SOP 52A (ČSN EN ISO 7027-1)","norm_bases":["SOP 52A","ČSN EN ISO 7027-1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie mętności metodą turbidymetryczną Vody Stanovení zákalu turbidimetricky SOP 52A (ČSN EN ISO 7027-1) Wody Oznaczanie metnosci metoda turbidymetryczna Vody Stanoveni zakalu turbidimetricky SOP 52A (CSN EN ISO 7027-1)","search_en":"Waters Determination of turbidity by turbidimetry SOP 52A (ČSN EN ISO 7027-1)","search_zh":"水 比浊法测定浊度 SOP 52A (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91408820cfdf8a22d9dd98b2","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"16","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie wapnia (Ca) i twardości ogólnej – sumy wapnia i magnezu (Ca + Mg) metodą miareczkową, magnezu (Mg) obliczeniowo z wyników pomiarów","methodology_en":"Determination of calcium (Ca) and total hardness – sum of calcium and magnesium (Ca + Mg) by titration, magnesium (Mg) by calculation from measured values","methodology_zh":"滴定法测定钙（Ca）和总硬度（钙镁总量Ca + Mg），由测得值计算镁（Mg）","methodology_cs":"Stanovení vápníku (Ca), stanovení celkové tvrdosti - sumy vápníku a hořčíku (Ca + Mg) titračně, stanovení hořčíku (Mg) výpočtem z naměřených hodnot","parameters":[{"name":"wapń (Ca)","range":""},{"name":"twardość ogólna – suma wapnia i magnezu (Ca + Mg)","range":""}],"parameters_en":[{"name":"calcium (Ca)","range":""},{"name":"total hardness – sum of calcium and magnesium (Ca + Mg)","range":""}],"parameters_zh":[{"name":"钙（Ca）","range":""},{"name":"总硬度 – 钙镁总量（Ca + Mg）","range":""}],"parameters_cs":[{"name":"vápníku (Ca)","range":""},{"name":"celkové tvrdosti - sumy vápníku a hořčíku (Ca + Mg)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["magnez (Mg)"],"computed_en":["magnesium (Mg)"],"computed_zh":["镁（Mg）"],"computed_cs":["hořčíku (Mg)"],"activity":"Oznaczanie wapnia (Ca) i twardości ogólnej – sumy wapnia i magnezu (Ca + Mg) metodą miareczkową, magnezu (Mg) obliczeniowo z wyników pomiarów\nZakres:\nwapń (Ca)\ntwardość ogólna – suma wapnia i magnezu (Ca + Mg)","reference":"SOP 12 (ČSN ISO 6058; ČSN ISO 6059)","norm_bases":["SOP 12","ČSN ISO 6058","ČSN ISO 6059"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie wapnia (Ca) i twardości ogólnej – sumy wapnia i magnezu (Ca + Mg) metodą miareczkową, magnezu (Mg) obliczeniowo z wyników pomiarów wapń (Ca)  twardość ogólna – suma wapnia i magnezu (Ca + Mg)  magnez (Mg) Vody, voda odpadní, výluhy Stanovení vápníku (Ca), stanovení celkové tvrdosti - sumy vápníku a hořčíku (Ca + Mg) titračně, stanovení hořčíku (Mg) výpočtem z naměřených hodnot vápníku (Ca)  celkové tvrdosti - sumy vápníku a hořčíku (Ca + Mg)  hořčíku (Mg) SOP 12 (ČSN ISO 6058; ČSN ISO 6059) Wody, scieki, wyciagi Oznaczanie wapnia (Ca) i twardosci ogolnej – sumy wapnia i magnezu (Ca + Mg) metoda miareczkowa, magnezu (Mg) obliczeniowo z wynikow pomiarow wapn (Ca)  twardosc ogolna – suma wapnia i magnezu (Ca + Mg)  magnez (Mg) Vody, voda odpadni, vyluhy Stanoveni vapniku (Ca), stanoveni celkove tvrdosti - sumy vapniku a horciku (Ca + Mg) titracne, stanoveni horciku (Mg) vypoctem z namerenych hodnot vapniku (Ca)  celkove tvrdosti - sumy vapniku a horciku (Ca + Mg)  horciku (Mg) SOP 12 (CSN ISO 6058; CSN ISO 6059)","search_en":"Waters, waste water, leachates Determination of calcium (Ca) and total hardness – sum of calcium and magnesium (Ca + Mg) by titration, magnesium (Mg) by calculation from measured values calcium (Ca)  total hardness – sum of calcium and magnesium (Ca + Mg)  magnesium (Mg) SOP 12 (ČSN ISO 6058; ČSN ISO 6059)","search_zh":"水、废水、浸出液 滴定法测定钙（Ca）和总硬度（钙镁总量Ca + Mg），由测得值计算镁（Mg） 钙（Ca）  总硬度 – 钙镁总量（Ca + Mg）  镁（Mg） SOP 12 (ČSN ISO 6058; ČSN ISO 6059)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c7797b919600c6f50fac32b5","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"17","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie chlorków (Cl-) metodą miareczkową","methodology_en":"Determination of chlorides (Cl-) by titration","methodology_zh":"滴定法测定氯化物（Cl-）","methodology_cs":"Stanovení chloridů (Cl-) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków (Cl-) metodą miareczkową","reference":"SOP 19 (ČSN ISO 9297)","norm_bases":["SOP 19","ČSN ISO 9297"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie chlorków (Cl-) metodą miareczkową Vody, voda odpadní, výluhy Stanovení chloridů (Cl-) titračně SOP 19 (ČSN ISO 9297) Wody, scieki, wyciagi Oznaczanie chlorkow (Cl-) metoda miareczkowa Vody, voda odpadni, vyluhy Stanoveni chloridu (Cl-) titracne SOP 19 (CSN ISO 9297)","search_en":"Waters, waste water, leachates Determination of chlorides (Cl-) by titration SOP 19 (ČSN ISO 9297)","search_zh":"水、废水、浸出液 滴定法测定氯化物（Cl-） SOP 19 (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b901276a1e26e4419498aad","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"18","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie fosforu ogólnego (Pc) i rozpuszczonych nieorganicznych ortofosforanów (PO43-) metodą spektrofotometryczną","methodology_en":"Determination of total phosphorus (Ptot) and dissolved inorganic orthophosphates (PO43-) by spectrophotometry","methodology_zh":"分光光度法测定总磷（Ptot）和溶解性无机正磷酸盐（PO43-）","methodology_cs":"Stanovení celkového fosforu (Pc) a rozpuštěných anorganických orthofosforečnanů (PO43-) spektrofotometricky","parameters":[{"name":"fosfor ogólny (Pc)","range":""},{"name":"rozpuszczone nieorganiczne ortofosforany (PO43-)","range":""}],"parameters_en":[{"name":"total phosphorus (Ptot)","range":""},{"name":"dissolved inorganic orthophosphates (PO43-)","range":""}],"parameters_zh":[{"name":"总磷（Ptot）","range":""},{"name":"溶解性无机正磷酸盐（PO43-）","range":""}],"parameters_cs":[{"name":"celkového fosforu (Pc)","range":""},{"name":"rozpuštěných anorganických orthofosforečnanů (PO43-)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu ogólnego (Pc) i rozpuszczonych nieorganicznych ortofosforanów (PO43-) metodą spektrofotometryczną\nZakres:\nfosfor ogólny (Pc)\nrozpuszczone nieorganiczne ortofosforany (PO43-)","reference":"SOP 17 (ČSN EN ISO 6878)","norm_bases":["SOP 17","ČSN EN ISO 6878"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie fosforu ogólnego (Pc) i rozpuszczonych nieorganicznych ortofosforanów (PO43-) metodą spektrofotometryczną fosfor ogólny (Pc)  rozpuszczone nieorganiczne ortofosforany (PO43-)  Vody, voda odpadní, výluhy Stanovení celkového fosforu (Pc) a rozpuštěných anorganických orthofosforečnanů (PO43-) spektrofotometricky celkového fosforu (Pc)  rozpuštěných anorganických orthofosforečnanů (PO43-)  SOP 17 (ČSN EN ISO 6878) Wody, scieki, wyciagi Oznaczanie fosforu ogolnego (Pc) i rozpuszczonych nieorganicznych ortofosforanow (PO43-) metoda spektrofotometryczna fosfor ogolny (Pc)  rozpuszczone nieorganiczne ortofosforany (PO43-)  Vody, voda odpadni, vyluhy Stanoveni celkoveho fosforu (Pc) a rozpustenych anorganickych orthofosforecnanu (PO43-) spektrofotometricky celkoveho fosforu (Pc)  rozpustenych anorganickych orthofosforecnanu (PO43-)  SOP 17 (CSN EN ISO 6878)","search_en":"Waters, waste water, leachates Determination of total phosphorus (Ptot) and dissolved inorganic orthophosphates (PO43-) by spectrophotometry total phosphorus (Ptot)  dissolved inorganic orthophosphates (PO43-)  SOP 17 (ČSN EN ISO 6878)","search_zh":"水、废水、浸出液 分光光度法测定总磷（Ptot）和溶解性无机正磷酸盐（PO43-） 总磷（Ptot）  溶解性无机正磷酸盐（PO43-）  SOP 17 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"93c10656f9d0f6f61a913cbf","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"19","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie azotanów (NO3-) metodą spektrofotometryczną i azotu azotanowego (N-NO3-) obliczeniowo z wyników pomiarów","methodology_en":"Determination of nitrates (NO3-) by spectrophotometry and nitrate nitrogen (N-NO3-) by calculation from measured values","methodology_zh":"分光光度法测定硝酸盐（NO3-），由测得值计算硝酸盐氮（N-NO3-）","methodology_cs":"Stanovení dusičnanů (NO3-) spektrofotometricky a dusičnanového dusíku (N-NO3-) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot azotanowy (N-NO3-)"],"computed_en":["nitrate nitrogen (N-NO3-)"],"computed_zh":["硝酸盐氮（N-NO3-）"],"computed_cs":["dusičnanového dusíku (N-NO3-)"],"activity":"Oznaczanie azotanów (NO3-) metodą spektrofotometryczną i azotu azotanowego (N-NO3-) obliczeniowo z wyników pomiarów","reference":"SOP 14 (ČSN 75 7455)","norm_bases":["SOP 14","ČSN 75 7455"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie azotanów (NO3-) metodą spektrofotometryczną i azotu azotanowego (N-NO3-) obliczeniowo z wyników pomiarów azot azotanowy (N-NO3-) Vody, voda odpadní, výluhy Stanovení dusičnanů (NO3-) spektrofotometricky a dusičnanového dusíku (N-NO3-) výpočtem z naměřených hodnot dusičnanového dusíku (N-NO3-) SOP 14 (ČSN 75 7455) Wody, scieki, wyciagi Oznaczanie azotanow (NO3-) metoda spektrofotometryczna i azotu azotanowego (N-NO3-) obliczeniowo z wynikow pomiarow azot azotanowy (N-NO3-) Vody, voda odpadni, vyluhy Stanoveni dusicnanu (NO3-) spektrofotometricky a dusicnanoveho dusiku (N-NO3-) vypoctem z namerenych hodnot dusicnanoveho dusiku (N-NO3-) SOP 14 (CSN 75 7455)","search_en":"Waters, waste water, leachates Determination of nitrates (NO3-) by spectrophotometry and nitrate nitrogen (N-NO3-) by calculation from measured values nitrate nitrogen (N-NO3-) SOP 14 (ČSN 75 7455)","search_zh":"水、废水、浸出液 分光光度法测定硝酸盐（NO3-），由测得值计算硝酸盐氮（N-NO3-） 硝酸盐氮（N-NO3-） SOP 14 (ČSN 75 7455)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dbc18d50dd5cc5d65f971a42","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"20","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie azotanów (NO3-) metodą spektrofotometryczną komercyjnym zestawem analitycznym i azotu azotanowego (N-NO3-) obliczeniowo z wyników pomiarów","methodology_en":"Determination of nitrates (NO3-) by spectrophotometry using a commercial analytical kit and nitrate nitrogen (N-NO3-) by calculation from measured values","methodology_zh":"使用商品化分析试剂盒分光光度法测定硝酸盐（NO3-），由测得值计算硝酸盐氮（N-NO3-）","methodology_cs":"Stanovení dusičnanů (NO3-) spektrofotometricky analytickou komerční soupravou a dusičnanového dusíku (N-NO3-) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot azotanowy (N-NO3-)"],"computed_en":["nitrate nitrogen (N-NO3-)"],"computed_zh":["硝酸盐氮（N-NO3-）"],"computed_cs":["dusičnanového dusíku (N-NO3-)"],"activity":"Oznaczanie azotanów (NO3-) metodą spektrofotometryczną komercyjnym zestawem analitycznym i azotu azotanowego (N-NO3-) obliczeniowo z wyników pomiarów","reference":"SOP 14A (návod firmy HACH)","norm_bases":["SOP 14A","návod firmy HACH"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie azotanów (NO3-) metodą spektrofotometryczną komercyjnym zestawem analitycznym i azotu azotanowego (N-NO3-) obliczeniowo z wyników pomiarów azot azotanowy (N-NO3-) Vody, voda odpadní, výluhy Stanovení dusičnanů (NO3-) spektrofotometricky analytickou komerční soupravou a dusičnanového dusíku (N-NO3-) výpočtem z naměřených hodnot dusičnanového dusíku (N-NO3-) SOP 14A (návod firmy HACH) Wody, scieki, wyciagi Oznaczanie azotanow (NO3-) metoda spektrofotometryczna komercyjnym zestawem analitycznym i azotu azotanowego (N-NO3-) obliczeniowo z wynikow pomiarow azot azotanowy (N-NO3-) Vody, voda odpadni, vyluhy Stanoveni dusicnanu (NO3-) spektrofotometricky analytickou komercni soupravou a dusicnanoveho dusiku (N-NO3-) vypoctem z namerenych hodnot dusicnanoveho dusiku (N-NO3-) SOP 14A (navod firmy HACH)","search_en":"Waters, waste water, leachates Determination of nitrates (NO3-) by spectrophotometry using a commercial analytical kit and nitrate nitrogen (N-NO3-) by calculation from measured values nitrate nitrogen (N-NO3-) SOP 14A (návod firmy HACH)","search_zh":"水、废水、浸出液 使用商品化分析试剂盒分光光度法测定硝酸盐（NO3-），由测得值计算硝酸盐氮（N-NO3-） 硝酸盐氮（N-NO3-） SOP 14A (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5acabf1c7c59584b8a91da49","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"21","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie azotynów (NO2-) metodą spektrofotometryczną oraz azotu azotynowego (N-NO2-) i azotu nieorganicznego obliczeniowo z wyników pomiarów","methodology_en":"Determination of nitrites (NO2-) by spectrophotometry and nitrite nitrogen (N-NO2-) and inorganic nitrogen by calculation from measured values","methodology_zh":"分光光度法测定亚硝酸盐（NO2-），由测得值计算亚硝酸盐氮（N-NO2-）和无机氮","methodology_cs":"Stanovení dusitanů (NO2-) spektrofotometricky a dusitanového dusíku (N-NO2-) a Nanorg. výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot azotynowy (N-NO2-)","azot nieorganiczny (Nnieorg.)"],"computed_en":["nitrite nitrogen (N-NO2-)","inorganic nitrogen (Ninorg.)"],"computed_zh":["亚硝酸盐氮（N-NO2-）","无机氮"],"computed_cs":["dusitanového dusíku (N-NO2-)","Nanorg."],"activity":"Oznaczanie azotynów (NO2-) metodą spektrofotometryczną oraz azotu azotynowego (N-NO2-) i azotu nieorganicznego obliczeniowo z wyników pomiarów","reference":"SOP 15 (ČSN EN 26777)","norm_bases":["SOP 15","ČSN EN 26777"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie azotynów (NO2-) metodą spektrofotometryczną oraz azotu azotynowego (N-NO2-) i azotu nieorganicznego obliczeniowo z wyników pomiarów azot azotynowy (N-NO2-) azot nieorganiczny (Nnieorg.) Vody, voda odpadní, výluhy Stanovení dusitanů (NO2-) spektrofotometricky a dusitanového dusíku (N-NO2-) a Nanorg. výpočtem z naměřených hodnot dusitanového dusíku (N-NO2-) Nanorg. SOP 15 (ČSN EN 26777) Wody, scieki, wyciagi Oznaczanie azotynow (NO2-) metoda spektrofotometryczna oraz azotu azotynowego (N-NO2-) i azotu nieorganicznego obliczeniowo z wynikow pomiarow azot azotynowy (N-NO2-) azot nieorganiczny (Nnieorg.) Vody, voda odpadni, vyluhy Stanoveni dusitanu (NO2-) spektrofotometricky a dusitanoveho dusiku (N-NO2-) a Nanorg. vypoctem z namerenych hodnot dusitanoveho dusiku (N-NO2-) Nanorg. SOP 15 (CSN EN 26777)","search_en":"Waters, waste water, leachates Determination of nitrites (NO2-) by spectrophotometry and nitrite nitrogen (N-NO2-) and inorganic nitrogen by calculation from measured values nitrite nitrogen (N-NO2-) inorganic nitrogen (Ninorg.) SOP 15 (ČSN EN 26777)","search_zh":"水、废水、浸出液 分光光度法测定亚硝酸盐（NO2-），由测得值计算亚硝酸盐氮（N-NO2-）和无机氮 亚硝酸盐氮（N-NO2-） 无机氮 SOP 15 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b03ed4de4d1f474f58595bfc","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"22","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną i azotu amonowego (N-NH4+) obliczeniowo z wyników pomiarów","methodology_en":"Determination of ammonium ions (NH4+) by spectrophotometry and ammonium nitrogen (N-NH4+) by calculation from measured values","methodology_zh":"分光光度法测定铵离子（NH4+），由测得值计算氨氮（N-NH4+）","methodology_cs":"Stanovení amonných iontů (NH4+) spektrofotometricky a amoniakálního dusíku (N-NH4+) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot amonowy (N-NH4+)"],"computed_en":["ammonium nitrogen (N-NH4+)"],"computed_zh":["氨氮（N-NH4+）"],"computed_cs":["amoniakálního dusíku (N-NH4+)"],"activity":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną i azotu amonowego (N-NH4+) obliczeniowo z wyników pomiarów","reference":"SOP 13A (ČSN ISO 7150-1)","norm_bases":["SOP 13A","ČSN ISO 7150-1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną i azotu amonowego (N-NH4+) obliczeniowo z wyników pomiarów azot amonowy (N-NH4+) Vody, voda odpadní, výluhy Stanovení amonných iontů (NH4+) spektrofotometricky a amoniakálního dusíku (N-NH4+) výpočtem z naměřených hodnot amoniakálního dusíku (N-NH4+) SOP 13A (ČSN ISO 7150-1) Wody, scieki, wyciagi Oznaczanie jonow amonowych (NH4+) metoda spektrofotometryczna i azotu amonowego (N-NH4+) obliczeniowo z wynikow pomiarow azot amonowy (N-NH4+) Vody, voda odpadni, vyluhy Stanoveni amonnych iontu (NH4+) spektrofotometricky a amoniakalniho dusiku (N-NH4+) vypoctem z namerenych hodnot amoniakalniho dusiku (N-NH4+) SOP 13A (CSN ISO 7150-1)","search_en":"Waters, waste water, leachates Determination of ammonium ions (NH4+) by spectrophotometry and ammonium nitrogen (N-NH4+) by calculation from measured values ammonium nitrogen (N-NH4+) SOP 13A (ČSN ISO 7150-1)","search_zh":"水、废水、浸出液 分光光度法测定铵离子（NH4+），由测得值计算氨氮（N-NH4+） 氨氮（N-NH4+） SOP 13A (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b2829f2f136b9587f6240ff","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"23","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie jonów amonowych (NH4+) po destylacji metodą miareczkową i azotu amonowego (N-NH4+) obliczeniowo z wyników pomiarów","methodology_en":"Determination of ammonium ions (NH4+) by titration after distillation and ammonium nitrogen (N-NH4+) by calculation from measured values","methodology_zh":"蒸馏后滴定法测定铵离子（NH4+），由测得值计算氨氮（N-NH4+）","methodology_cs":"Stanovení amonných iontů (NH4+) po destilaci titračně a amoniakálního dusíku (N-NH4+) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot amonowy (N-NH4+)"],"computed_en":["ammonium nitrogen (N-NH4+)"],"computed_zh":["氨氮（N-NH4+）"],"computed_cs":["amoniakálního dusíku (N-NH4+)"],"activity":"Oznaczanie jonów amonowych (NH4+) po destylacji metodą miareczkową i azotu amonowego (N-NH4+) obliczeniowo z wyników pomiarów","reference":"SOP 13B (ČSN ISO 5664)","norm_bases":["SOP 13B","ČSN ISO 5664"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie jonów amonowych (NH4+) po destylacji metodą miareczkową i azotu amonowego (N-NH4+) obliczeniowo z wyników pomiarów azot amonowy (N-NH4+) Vody, voda odpadní, výluhy Stanovení amonných iontů (NH4+) po destilaci titračně a amoniakálního dusíku (N-NH4+) výpočtem z naměřených hodnot amoniakálního dusíku (N-NH4+) SOP 13B (ČSN ISO 5664) Wody, scieki, wyciagi Oznaczanie jonow amonowych (NH4+) po destylacji metoda miareczkowa i azotu amonowego (N-NH4+) obliczeniowo z wynikow pomiarow azot amonowy (N-NH4+) Vody, voda odpadni, vyluhy Stanoveni amonnych iontu (NH4+) po destilaci titracne a amoniakalniho dusiku (N-NH4+) vypoctem z namerenych hodnot amoniakalniho dusiku (N-NH4+) SOP 13B (CSN ISO 5664)","search_en":"Waters, waste water, leachates Determination of ammonium ions (NH4+) by titration after distillation and ammonium nitrogen (N-NH4+) by calculation from measured values ammonium nitrogen (N-NH4+) SOP 13B (ČSN ISO 5664)","search_zh":"水、废水、浸出液 蒸馏后滴定法测定铵离子（NH4+），由测得值计算氨氮（N-NH4+） 氨氮（N-NH4+） SOP 13B (ČSN ISO 5664)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d92542fe6361f2d3ff0c3e6","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"24","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie azotu ogólnego (Nog.) i azotu organicznego (Norg.) metodą miareczkową Kjeldahla","methodology_en":"Determination of total nitrogen (Ntot) and organic nitrogen (Norg) by the Kjeldahl titration method","methodology_zh":"凯氏滴定法测定总氮（Ntot）和有机氮（Norg）","methodology_cs":"Stanovení dusíku celkového (Ncelk.) a dusíku organického (Norg.) titrační metodou dle Kjeldahla","parameters":[{"name":"azot ogólny","range":""},{"name":"azot organiczny","range":""}],"parameters_en":[{"name":"total nitrogen","range":""},{"name":"organic nitrogen","range":""}],"parameters_zh":[{"name":"总氮","range":""},{"name":"有机氮","range":""}],"parameters_cs":[{"name":"dusíku celkového (Ncelk.)","range":""},{"name":"dusíku organického (Norg.)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego (Nog.) i azotu organicznego (Norg.) metodą miareczkową Kjeldahla\nZakres:\nazot ogólny\nazot organiczny","reference":"SOP 63 (ČSN EN 25663)","norm_bases":["SOP 63","ČSN EN 25663"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie azotu ogólnego (Nog.) i azotu organicznego (Norg.) metodą miareczkową Kjeldahla azot ogólny  azot organiczny  Vody, voda odpadní, výluhy Stanovení dusíku celkového (Ncelk.) a dusíku organického (Norg.) titrační metodou dle Kjeldahla dusíku celkového (Ncelk.)  dusíku organického (Norg.)  SOP 63 (ČSN EN 25663) Wody, scieki, wyciagi Oznaczanie azotu ogolnego (Nog.) i azotu organicznego (Norg.) metoda miareczkowa Kjeldahla azot ogolny  azot organiczny  Vody, voda odpadni, vyluhy Stanoveni dusiku celkoveho (Ncelk.) a dusiku organickeho (Norg.) titracni metodou dle Kjeldahla dusiku celkoveho (Ncelk.)  dusiku organickeho (Norg.)  SOP 63 (CSN EN 25663)","search_en":"Waters, waste water, leachates Determination of total nitrogen (Ntot) and organic nitrogen (Norg) by the Kjeldahl titration method total nitrogen  organic nitrogen  SOP 63 (ČSN EN 25663)","search_zh":"水、废水、浸出液 凯氏滴定法测定总氮（Ntot）和有机氮（Norg） 总氮  有机氮  SOP 63 (ČSN EN 25663)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"740ad70a784bb154debb7337","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"25","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie absorbancji","methodology_en":"Determination of absorbance","methodology_zh":"吸光度测定","methodology_cs":"Stanovení absorbance","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie absorbancji","reference":"SOP 44 (ČSN 75 7360)","norm_bases":["SOP 44","ČSN 75 7360"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie absorbancji Vody Stanovení absorbance SOP 44 (ČSN 75 7360) Wody Oznaczanie absorbancji Vody Stanoveni absorbance SOP 44 (CSN 75 7360)","search_en":"Waters Determination of absorbance SOP 44 (ČSN 75 7360)","search_zh":"水 吸光度测定 SOP 44 (ČSN 75 7360)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7cbc2a4e0f91816c0bf5dad7","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"26","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie substancji humusowych metodą spektrofotometryczną","methodology_en":"Determination of humic substances by spectrophotometry","methodology_zh":"分光光度法测定腐殖质","methodology_cs":"Stanovení huminových látek spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji humusowych metodą spektrofotometryczną","reference":"SOP 45 (ČSN 75 7536)","norm_bases":["SOP 45","ČSN 75 7536"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie substancji humusowych metodą spektrofotometryczną Vody Stanovení huminových látek spektrofotometricky SOP 45 (ČSN 75 7536) Wody Oznaczanie substancji humusowych metoda spektrofotometryczna Vody Stanoveni huminovych latek spektrofotometricky SOP 45 (CSN 75 7536)","search_en":"Waters Determination of humic substances by spectrophotometry SOP 45 (ČSN 75 7536)","search_zh":"水 分光光度法测定腐殖质 SOP 45 (ČSN 75 7536)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"17c804e368c04348aa1d05b1","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"27","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity by nephelometry","methodology_zh":"浊度法测定浊度","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną","reference":"SOP 52B (ČSN EN ISO 7027-1)","norm_bases":["SOP 52B","ČSN EN ISO 7027-1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie mętności metodą nefelometryczną Vody Stanovení zákalu nefelometricky SOP 52B (ČSN EN ISO 7027-1) Wody Oznaczanie metnosci metoda nefelometryczna Vody Stanoveni zakalu nefelometricky SOP 52B (CSN EN ISO 7027-1)","search_en":"Waters Determination of turbidity by nephelometry SOP 52B (ČSN EN ISO 7027-1)","search_zh":"水 浊度法测定浊度 SOP 52B (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6507ec6a2513faa6a594f9e6","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"28","test_object":"Pasze, materiał roślinny, produkty rolne","test_object_en":"Feeds, plant material, agricultural products","test_object_zh":"饲料、植物材料、农产品","test_object_cs":"Krmiva, rostlinný materiál, zemědělské produkty","methodology":"Oznaczanie suchej masy, wilgotności, straty przy prażeniu i popiołu metodą wagową","methodology_en":"Determination of dry matter, moisture, loss on ignition and ash by gravimetry","methodology_zh":"重量法测定干物质、水分、灼烧损失和灰分","methodology_cs":"Stanovení sušiny, vlhkosti, ztráty žíháním a popele gravimetricky","parameters":[{"name":"sucha masa","range":""},{"name":"wilgotność","range":""},{"name":"strata przy prażeniu","range":""},{"name":"popiół","range":""}],"parameters_en":[{"name":"dry matter","range":""},{"name":"moisture","range":""},{"name":"loss on ignition","range":""},{"name":"ash","range":""}],"parameters_zh":[{"name":"干物质","range":""},{"name":"水分","range":""},{"name":"灼烧损失","range":""},{"name":"灰分","range":""}],"parameters_cs":[{"name":"sušiny","range":""},{"name":"vlhkosti","range":""},{"name":"ztráty žíháním","range":""},{"name":"popele","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy, wilgotności, straty przy prażeniu i popiołu metodą wagową\nZakres:\nsucha masa\nwilgotność\nstrata przy prażeniu\npopiół","reference":"SOP 25B (JPP ÚKZÚZ č. postupu 10001.1, 10002.1, 10004.1 40010.1, 50010.1)","norm_bases":["SOP 25B","JPP ÚKZÚZ č. postupu 10001.1, 10002.1, 10004.1 40010.1, 50010.1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze, materiał roślinny, produkty rolne Oznaczanie suchej masy, wilgotności, straty przy prażeniu i popiołu metodą wagową sucha masa  wilgotność  strata przy prażeniu  popiół  Krmiva, rostlinný materiál, zemědělské produkty Stanovení sušiny, vlhkosti, ztráty žíháním a popele gravimetricky sušiny  vlhkosti  ztráty žíháním  popele  SOP 25B (JPP ÚKZÚZ č. postupu 10001.1, 10002.1, 10004.1 40010.1, 50010.1) Pasze, material roslinny, produkty rolne Oznaczanie suchej masy, wilgotnosci, straty przy prazeniu i popiolu metoda wagowa sucha masa  wilgotnosc  strata przy prazeniu  popiol  Krmiva, rostlinny material, zemedelske produkty Stanoveni susiny, vlhkosti, ztraty zihanim a popele gravimetricky susiny  vlhkosti  ztraty zihanim  popele  SOP 25B (JPP UKZUZ c. postupu 10001.1, 10002.1, 10004.1 40010.1, 50010.1)","search_en":"Feeds, plant material, agricultural products Determination of dry matter, moisture, loss on ignition and ash by gravimetry dry matter  moisture  loss on ignition  ash  SOP 25B (JPP ÚKZÚZ č. postupu 10001.1, 10002.1, 10004.1 40010.1, 50010.1)","search_zh":"饲料、植物材料、农产品 重量法测定干物质、水分、灼烧损失和灰分 干物质  水分  灼烧损失  灰分  SOP 25B (JPP ÚKZÚZ č. postupu 10001.1, 10002.1, 10004.1 40010.1, 50010.1)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9aef5edf44a5d591f212071a","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"29","test_object":"Grunt (gleba)","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Zemina","methodology":"Oznaczanie azotu amonowego metodą spektrofotometryczną i azotu mineralnego obliczeniowo z wyników pomiarów","methodology_en":"Determination of ammonium nitrogen by spectrophotometry and mineral nitrogen by calculation from measured values","methodology_zh":"分光光度法测定氨氮，由测得值计算矿质氮","methodology_cs":"Stanovení amoniakálního dusíku spektrofotometricky a minerálního dusíku výpočtem z naměřených hodnot","parameters":[{"name":"azot amonowy","range":""}],"parameters_en":[{"name":"ammonium nitrogen","range":""}],"parameters_zh":[{"name":"氨氮","range":""}],"parameters_cs":[{"name":"amoniakálního dusíku","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot mineralny"],"computed_en":["mineral nitrogen"],"computed_zh":["矿质氮"],"computed_cs":["minerálního dusíku"],"activity":"Oznaczanie azotu amonowego metodą spektrofotometryczną i azotu mineralnego obliczeniowo z wyników pomiarów\nazot amonowy","reference":"SOP 69 (JPP ÚKZÚZ č. postupu 30930.1, 30937.1)","norm_bases":["SOP 69","JPP ÚKZÚZ č. postupu 30930.1, 30937.1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt (gleba) Oznaczanie azotu amonowego metodą spektrofotometryczną i azotu mineralnego obliczeniowo z wyników pomiarów azot amonowy  azot mineralny Zemina Stanovení amoniakálního dusíku spektrofotometricky a minerálního dusíku výpočtem z naměřených hodnot amoniakálního dusíku  minerálního dusíku SOP 69 (JPP ÚKZÚZ č. postupu 30930.1, 30937.1) Grunt (gleba) Oznaczanie azotu amonowego metoda spektrofotometryczna i azotu mineralnego obliczeniowo z wynikow pomiarow azot amonowy  azot mineralny Zemina Stanoveni amoniakalniho dusiku spektrofotometricky a mineralniho dusiku vypoctem z namerenych hodnot amoniakalniho dusiku  mineralniho dusiku SOP 69 (JPP UKZUZ c. postupu 30930.1, 30937.1)","search_en":"Soil Determination of ammonium nitrogen by spectrophotometry and mineral nitrogen by calculation from measured values ammonium nitrogen  mineral nitrogen SOP 69 (JPP ÚKZÚZ č. postupu 30930.1, 30937.1)","search_zh":"土壤 分光光度法测定氨氮，由测得值计算矿质氮 氨氮  矿质氮 SOP 69 (JPP ÚKZÚZ č. postupu 30930.1, 30937.1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6029356e8d7c274d3e6a5739","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"30","test_object":"Grunt (gleba)","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Zemina","methodology":"Oznaczanie azotu azotanowego metodą spektrofotometryczną","methodology_en":"Determination of nitrate nitrogen by spectrophotometry","methodology_zh":"分光光度法测定硝酸盐氮","methodology_cs":"Stanovení dusičnanového dusíku spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu azotanowego metodą spektrofotometryczną","reference":"SOP 70 (JPP ÚKZÚZ č. postupu 30930.1, 30931.1)","norm_bases":["SOP 70","JPP ÚKZÚZ č. postupu 30930.1, 30931.1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt (gleba) Oznaczanie azotu azotanowego metodą spektrofotometryczną Zemina Stanovení dusičnanového dusíku spektrofotometricky SOP 70 (JPP ÚKZÚZ č. postupu 30930.1, 30931.1) Grunt (gleba) Oznaczanie azotu azotanowego metoda spektrofotometryczna Zemina Stanoveni dusicnanoveho dusiku spektrofotometricky SOP 70 (JPP UKZUZ c. postupu 30930.1, 30931.1)","search_en":"Soil Determination of nitrate nitrogen by spectrophotometry SOP 70 (JPP ÚKZÚZ č. postupu 30930.1, 30931.1)","search_zh":"土壤 分光光度法测定硝酸盐氮 SOP 70 (JPP ÚKZÚZ č. postupu 30930.1, 30931.1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3fded7b563cc33f1de52d274","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"31","test_object":"Grunt (gleba)","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Zemina","methodology":"Oznaczanie azotu azotanowego metodą spektrofotometryczną komercyjnym zestawem analitycznym","methodology_en":"Determination of nitrate nitrogen by spectrophotometry using a commercial analytical kit","methodology_zh":"使用商品化分析试剂盒分光光度法测定硝酸盐氮","methodology_cs":"Stanovení dusičnanového dusíku spektrofotometricky analytickou komerční soupravou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu azotanowego metodą spektrofotometryczną komercyjnym zestawem analitycznym","reference":"SOP 70A (návod firmy HACH)","norm_bases":["SOP 70A","návod firmy HACH"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt (gleba) Oznaczanie azotu azotanowego metodą spektrofotometryczną komercyjnym zestawem analitycznym Zemina Stanovení dusičnanového dusíku spektrofotometricky analytickou komerční soupravou SOP 70A (návod firmy HACH) Grunt (gleba) Oznaczanie azotu azotanowego metoda spektrofotometryczna komercyjnym zestawem analitycznym Zemina Stanoveni dusicnanoveho dusiku spektrofotometricky analytickou komercni soupravou SOP 70A (navod firmy HACH)","search_en":"Soil Determination of nitrate nitrogen by spectrophotometry using a commercial analytical kit SOP 70A (návod firmy HACH)","search_zh":"土壤 使用商品化分析试剂盒分光光度法测定硝酸盐氮 SOP 70A (návod firmy HACH)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b65e56fad56d94f0c6350955","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"32","test_object":"Grunt, osad, osad denny, bioodpad, nawozy, wsad i poferment z biogazowni","test_object_en":"Soil, sludge, sediment, biowaste, fertilisers, input and output of biogas plants","test_object_zh":"土壤、污泥、沉积物、生物废物、肥料、沼气厂进料和出料","test_object_cs":"Zemina, kal, sediment, bioodpad, hnojiva, vstup a výstup z BPS","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP 18 (JPP ÚKZÚZ č. postupu 20221.1, 20376.1, 30040.1, 30041.1, 30042.1; ČSN EN ISO 10390; ČSN 46 5735)","norm_bases":["SOP 18","JPP ÚKZÚZ č. postupu 20221.1, 20376.1, 30040.1, 30041.1, 30042.1","ČSN EN ISO 10390","ČSN 46 5735"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Bioodpad – kompost, surowce wsadowe do kompostowania. Nawozy – komposty, nawozy organiczne, organiczno-mineralne, mineralne, wapniowe i środki wspomagające uprawę (woda technologiczna)","note_en":"Biowaste – compost, input materials for composting. Fertilisers – composts, organic, organo-mineral, mineral, calcareous fertilisers and soil improvers (process water)","note_zh":"生物废物 – 堆肥、堆肥原料。肥料 – 堆肥、有机肥、有机无机复混肥、矿物肥、石灰质肥料和土壤改良剂（工艺用水）","note_cs":"Bioodpad – kompost, vstupní suroviny do kompostů. Hnojiva – komposty, organická, organominerální, minerální, vápenatá hnojiva a pomocné půdní látky (technologická voda)","search_text":"Grunt, osad, osad denny, bioodpad, nawozy, wsad i poferment z biogazowni Oznaczanie pH metodą potencjometryczną Zemina, kal, sediment, bioodpad, hnojiva, vstup a výstup z BPS Stanovení pH potenciometricky SOP 18 (JPP ÚKZÚZ č. postupu 20221.1, 20376.1, 30040.1, 30041.1, 30042.1; ČSN EN ISO 10390; ČSN 46 5735) Grunt, osad, osad denny, bioodpad, nawozy, wsad i poferment z biogazowni Oznaczanie pH metoda potencjometryczna Zemina, kal, sediment, bioodpad, hnojiva, vstup a vystup z BPS Stanoveni pH potenciometricky SOP 18 (JPP UKZUZ c. postupu 20221.1, 20376.1, 30040.1, 30041.1, 30042.1; CSN EN ISO 10390; CSN 46 5735)","search_en":"Soil, sludge, sediment, biowaste, fertilisers, input and output of biogas plants Determination of pH by potentiometry SOP 18 (JPP ÚKZÚZ č. postupu 20221.1, 20376.1, 30040.1, 30041.1, 30042.1; ČSN EN ISO 10390; ČSN 46 5735)","search_zh":"土壤、污泥、沉积物、生物废物、肥料、沼气厂进料和出料 电位法测定pH SOP 18 (JPP ÚKZÚZ č. postupu 20221.1, 20376.1, 30040.1, 30041.1, 30042.1; ČSN EN ISO 10390; ČSN 46 5735)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0e621eed9b05304b6f5f13f7","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"33","test_object":"Grunt (gleba)","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Zemina","methodology":"Oznaczanie fosforu (P) metodą spektrofotometryczną","methodology_en":"Determination of phosphorus (P) by spectrophotometry","methodology_zh":"分光光度法测定磷（P）","methodology_cs":"Stanovení fosforu (P) spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu (P) metodą spektrofotometryczną","reference":"SOP 22 (JPP ÚKZÚZ č. postupu 30072.1)","norm_bases":["SOP 22","JPP ÚKZÚZ č. postupu 30072.1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt (gleba) Oznaczanie fosforu (P) metodą spektrofotometryczną Zemina Stanovení fosforu (P) spektrofotometricky SOP 22 (JPP ÚKZÚZ č. postupu 30072.1) Grunt (gleba) Oznaczanie fosforu (P) metoda spektrofotometryczna Zemina Stanoveni fosforu (P) spektrofotometricky SOP 22 (JPP UKZUZ c. postupu 30072.1)","search_en":"Soil Determination of phosphorus (P) by spectrophotometry SOP 22 (JPP ÚKZÚZ č. postupu 30072.1)","search_zh":"土壤 分光光度法测定磷（P） SOP 22 (JPP ÚKZÚZ č. postupu 30072.1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e7d42c2c19dae8a2080b382a","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"34","test_object":"Osad, osad denny, bioodpad, nawozy organiczne, wsad i poferment z biogazowni, grunt","test_object_en":"Sludge, sediment, biowaste, organic fertilisers, input and output of biogas plants, soil","test_object_zh":"污泥、沉积物、生物废物、有机肥、沼气厂进料和出料、土壤","test_object_cs":"Kal, sediment, bioodpad, organická hnojiva, vstup a výstup z BPS, zemina","methodology":"Oznaczanie azotu ogólnego metodą miareczkową Kjeldahla","methodology_en":"Determination of total nitrogen (Ntot) by Kjeldahl titration","methodology_zh":"凯氏滴定法测定总氮（Ntot）","methodology_cs":"Stanovení celkového dusíku (Ncelk.) titračně dle Kjeldahla","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego metodą miareczkową Kjeldahla","reference":"SOP 28 (ČSN 46 5735; ČSN EN 13342; ČSN EN 16169)","norm_bases":["SOP 28","ČSN 46 5735","ČSN EN 13342","ČSN EN 16169"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Bioodpad – kompost, surowce wsadowe do kompostowania. Nawozy – komposty, nawozy organiczne, organiczno-mineralne, mineralne, wapniowe i środki wspomagające uprawę (woda technologiczna)","note_en":"Biowaste – compost, input materials for composting. Fertilisers – composts, organic, organo-mineral, mineral, calcareous fertilisers and soil improvers (process water)","note_zh":"生物废物 – 堆肥、堆肥原料。肥料 – 堆肥、有机肥、有机无机复混肥、矿物肥、石灰质肥料和土壤改良剂（工艺用水）","note_cs":"Bioodpad – kompost, vstupní suroviny do kompostů. Hnojiva – komposty, organická, organominerální, minerální, vápenatá hnojiva a pomocné půdní látky (technologická voda)","search_text":"Osad, osad denny, bioodpad, nawozy organiczne, wsad i poferment z biogazowni, grunt Oznaczanie azotu ogólnego metodą miareczkową Kjeldahla Kal, sediment, bioodpad, organická hnojiva, vstup a výstup z BPS, zemina Stanovení celkového dusíku (Ncelk.) titračně dle Kjeldahla SOP 28 (ČSN 46 5735; ČSN EN 13342; ČSN EN 16169) Osad, osad denny, bioodpad, nawozy organiczne, wsad i poferment z biogazowni, grunt Oznaczanie azotu ogolnego metoda miareczkowa Kjeldahla Kal, sediment, bioodpad, organicka hnojiva, vstup a vystup z BPS, zemina Stanoveni celkoveho dusiku (Ncelk.) titracne dle Kjeldahla SOP 28 (CSN 46 5735; CSN EN 13342; CSN EN 16169)","search_en":"Sludge, sediment, biowaste, organic fertilisers, input and output of biogas plants, soil Determination of total nitrogen (Ntot) by Kjeldahl titration SOP 28 (ČSN 46 5735; ČSN EN 13342; ČSN EN 16169)","search_zh":"污泥、沉积物、生物废物、有机肥、沼气厂进料和出料、土壤 凯氏滴定法测定总氮（Ntot） SOP 28 (ČSN 46 5735; ČSN EN 13342; ČSN EN 16169)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b27cf9dd0046078b5b93911","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"35","test_object":"Grunt, odpad, osad, osad denny, nawozy, wsad i poferment z biogazowni","test_object_en":"Soil, waste, sludge, sediment, fertilisers, input and output of biogas plants","test_object_zh":"土壤、废物、污泥、沉积物、肥料、沼气厂进料和出料","test_object_cs":"Zemina, odpad, kal, sediment, hnojiva, vstup a výstup z BPS","methodology":"Oznaczanie suchej masy, wilgotności i straty przy prażeniu metodą wagową","methodology_en":"Determination of dry matter, moisture and loss on ignition by gravimetry","methodology_zh":"重量法测定干物质、水分和灼烧损失","methodology_cs":"Stanovení sušiny, vlhkosti, ztráty žíháním gravimetricky","parameters":[{"name":"sucha masa","range":""},{"name":"wilgotność","range":""},{"name":"strata przy prażeniu","range":""}],"parameters_en":[{"name":"dry matter","range":""},{"name":"moisture","range":""},{"name":"loss on ignition","range":""}],"parameters_zh":[{"name":"干物质","range":""},{"name":"水分","range":""},{"name":"灼烧损失","range":""}],"parameters_cs":[{"name":"sušiny","range":""},{"name":"vlhkosti","range":""},{"name":"ztráty žíháním","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy, wilgotności i straty przy prażeniu metodą wagową\nZakres:\nsucha masa\nwilgotność\nstrata przy prażeniu","reference":"SOP 25A (ČSN ISO 11465; ČSN EN 12880; ČSN EN 15934; ČSN EN 15935; ČSN 46 5735)","norm_bases":["SOP 25A","ČSN ISO 11465","ČSN EN 12880","ČSN EN 15934","ČSN EN 15935","ČSN 46 5735"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Odpad – stały, ciekły, bioodpad, materiały budowlane i rozbiórkowe. Bioodpad – kompost, surowce wsadowe do kompostowania. Nawozy – komposty, nawozy organiczne, organiczno-mineralne, mineralne, wapniowe i środki wspomagające uprawę (woda technologiczna)","note_en":"Waste – solid, liquid, biowaste, construction and demolition materials. Biowaste – compost, input materials for composting. Fertilisers – composts, organic, organo-mineral, mineral, calcareous fertilisers and soil improvers (process water)","note_zh":"废物 – 固体、液体、生物废物、建筑和拆除材料。生物废物 – 堆肥、堆肥原料。肥料 – 堆肥、有机肥、有机无机复混肥、矿物肥、石灰质肥料和土壤改良剂（工艺用水）","note_cs":"Odpad – pevný, kapalný, bioodpad, stavební a demoliční materiály. Bioodpad – kompost, vstupní suroviny do kompostů. Hnojiva – komposty, organická, organominerální, minerální, vápenatá hnojiva a pomocné půdní látky (technologická voda)","search_text":"Grunt, odpad, osad, osad denny, nawozy, wsad i poferment z biogazowni Oznaczanie suchej masy, wilgotności i straty przy prażeniu metodą wagową sucha masa  wilgotność  strata przy prażeniu  Zemina, odpad, kal, sediment, hnojiva, vstup a výstup z BPS Stanovení sušiny, vlhkosti, ztráty žíháním gravimetricky sušiny  vlhkosti  ztráty žíháním  SOP 25A (ČSN ISO 11465; ČSN EN 12880; ČSN EN 15934; ČSN EN 15935; ČSN 46 5735) Grunt, odpad, osad, osad denny, nawozy, wsad i poferment z biogazowni Oznaczanie suchej masy, wilgotnosci i straty przy prazeniu metoda wagowa sucha masa  wilgotnosc  strata przy prazeniu  Zemina, odpad, kal, sediment, hnojiva, vstup a vystup z BPS Stanoveni susiny, vlhkosti, ztraty zihanim gravimetricky susiny  vlhkosti  ztraty zihanim  SOP 25A (CSN ISO 11465; CSN EN 12880; CSN EN 15934; CSN EN 15935; CSN 46 5735)","search_en":"Soil, waste, sludge, sediment, fertilisers, input and output of biogas plants Determination of dry matter, moisture and loss on ignition by gravimetry dry matter  moisture  loss on ignition  SOP 25A (ČSN ISO 11465; ČSN EN 12880; ČSN EN 15934; ČSN EN 15935; ČSN 46 5735)","search_zh":"土壤、废物、污泥、沉积物、肥料、沼气厂进料和出料 重量法测定干物质、水分和灼烧损失 干物质  水分  灼烧损失  SOP 25A (ČSN ISO 11465; ČSN EN 12880; ČSN EN 15934; ČSN EN 15935; ČSN 46 5735)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22330b328a23156022aa1165","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"36","test_object":"Wody, ścieki, wyciągi, grunt, odpad, osad, osad denny, żywność, materiał roślinny, pasze, nawozy","test_object_en":"Waters, waste water, leachates, soil, waste, sludge, sediment, foods, plant material, feeds, fertilisers","test_object_zh":"水、废水、浸出液、土壤、废物、污泥、沉积物、食品、植物材料、饲料、肥料","test_object_cs":"Vody, voda odpadní, výluhy, zemina, odpad, kal, sediment, potraviny, rostlinný materiál, krmiva, hnojiva","methodology":"Oznaczanie Hg analizatorem AMA","methodology_en":"Determination of Hg using an AMA analyser","methodology_zh":"AMA测汞仪测定汞","methodology_cs":"Stanovení Hg analyzátorem AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Hg analizatorem AMA","reference":"SOP 27 (ČSN 75 7440; ČSN 46 5735; JPP ÚKZÚZ č. postupu 10420.1, 20110.1, 30460.1, 40190.1)","norm_bases":["SOP 27","ČSN 75 7440","ČSN 46 5735","JPP ÚKZÚZ č. postupu 10420.1, 20110.1, 30460.1, 40190.1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Odpad – stały, ciekły, bioodpad, materiały budowlane i rozbiórkowe. Bioodpad – kompost, surowce wsadowe do kompostowania. Nawozy – komposty, nawozy organiczne, organiczno-mineralne, mineralne, wapniowe i środki wspomagające uprawę (woda technologiczna). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Waste – solid, liquid, biowaste, construction and demolition materials. Biowaste – compost, input materials for composting. Fertilisers – composts, organic, organo-mineral, mineral, calcareous fertilisers and soil improvers (process water). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。废物 – 固体、液体、生物废物、建筑和拆除材料。生物废物 – 堆肥、堆肥原料。肥料 – 堆肥、有机肥、有机无机复混肥、矿物肥、石灰质肥料和土壤改良剂（工艺用水）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Odpad – pevný, kapalný, bioodpad, stavební a demoliční materiály. Bioodpad – kompost, vstupní suroviny do kompostů. Hnojiva – komposty, organická, organominerální, minerální, vápenatá hnojiva a pomocné půdní látky (technologická voda). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi, grunt, odpad, osad, osad denny, żywność, materiał roślinny, pasze, nawozy Oznaczanie Hg analizatorem AMA Vody, voda odpadní, výluhy, zemina, odpad, kal, sediment, potraviny, rostlinný materiál, krmiva, hnojiva Stanovení Hg analyzátorem AMA SOP 27 (ČSN 75 7440; ČSN 46 5735; JPP ÚKZÚZ č. postupu 10420.1, 20110.1, 30460.1, 40190.1) Wody, scieki, wyciagi, grunt, odpad, osad, osad denny, zywnosc, material roslinny, pasze, nawozy Oznaczanie Hg analizatorem AMA Vody, voda odpadni, vyluhy, zemina, odpad, kal, sediment, potraviny, rostlinny material, krmiva, hnojiva Stanoveni Hg analyzatorem AMA SOP 27 (CSN 75 7440; CSN 46 5735; JPP UKZUZ c. postupu 10420.1, 20110.1, 30460.1, 40190.1)","search_en":"Waters, waste water, leachates, soil, waste, sludge, sediment, foods, plant material, feeds, fertilisers Determination of Hg using an AMA analyser SOP 27 (ČSN 75 7440; ČSN 46 5735; JPP ÚKZÚZ č. postupu 10420.1, 20110.1, 30460.1, 40190.1)","search_zh":"水、废水、浸出液、土壤、废物、污泥、沉积物、食品、植物材料、饲料、肥料 AMA测汞仪测定汞 SOP 27 (ČSN 75 7440; ČSN 46 5735; JPP ÚKZÚZ č. postupu 10420.1, 20110.1, 30460.1, 40190.1)","categories":["water","environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"821df71b8ff6549967795fd4","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"37","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie chromu sześciowartościowego (Cr6+) metodą spektrofotometryczną","methodology_en":"Determination of hexavalent chromium (Cr6+) by spectrophotometry","methodology_zh":"分光光度法测定六价铬（Cr6+）","methodology_cs":"Stanovení Cr šestimocného (Cr6+) spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chromu sześciowartościowego (Cr6+) metodą spektrofotometryczną","reference":"SOP 26 (ČSN ISO 11083)","norm_bases":["SOP 26","ČSN ISO 11083"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie chromu sześciowartościowego (Cr6+) metodą spektrofotometryczną Vody, voda odpadní, výluhy Stanovení Cr šestimocného (Cr6+) spektrofotometricky SOP 26 (ČSN ISO 11083) Wody, scieki, wyciagi Oznaczanie chromu szesciowartosciowego (Cr6+) metoda spektrofotometryczna Vody, voda odpadni, vyluhy Stanoveni Cr sestimocneho (Cr6+) spektrofotometricky SOP 26 (CSN ISO 11083)","search_en":"Waters, waste water, leachates Determination of hexavalent chromium (Cr6+) by spectrophotometry SOP 26 (ČSN ISO 11083)","search_zh":"水、废水、浸出液 分光光度法测定六价铬（Cr6+） SOP 26 (ČSN ISO 11083)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a2aa7125ed040910a6f8de67","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"38","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie boru (B) metodą spektrofotometryczną","methodology_en":"Determination of boron (B) by spectrophotometry","methodology_zh":"分光光度法测定硼（B）","methodology_cs":"Stanovení boru (B) spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie boru (B) metodą spektrofotometryczną","reference":"SOP 46 (ČSN ISO 9390)","norm_bases":["SOP 46","ČSN ISO 9390"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie boru (B) metodą spektrofotometryczną Vody, voda odpadní, výluhy Stanovení boru (B) spektrofotometricky SOP 46 (ČSN ISO 9390) Wody, scieki, wyciagi Oznaczanie boru (B) metoda spektrofotometryczna Vody, voda odpadni, vyluhy Stanoveni boru (B) spektrofotometricky SOP 46 (CSN ISO 9390)","search_en":"Waters, waste water, leachates Determination of boron (B) by spectrophotometry SOP 46 (ČSN ISO 9390)","search_zh":"水、废水、浸出液 分光光度法测定硼（B） SOP 46 (ČSN ISO 9390)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f6848ff42943cab5f942b95","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"39","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie cyjanków ogólnych i łatwo uwalnialnych metodą spektrofotometryczną","methodology_en":"Determination of total and easily liberatable cyanides by spectrophotometry","methodology_zh":"分光光度法测定总氰化物和易释放氰化物","methodology_cs":"Stanovení celkových a snadno uvolnitelných kyanidů spektrofotometricky","parameters":[{"name":"cyjanki ogólne","range":""},{"name":"cyjanki łatwo uwalnialne","range":""}],"parameters_en":[{"name":"total cyanides","range":""},{"name":"easily liberatable cyanides","range":""}],"parameters_zh":[{"name":"总氰化物","range":""},{"name":"易释放氰化物","range":""}],"parameters_cs":[{"name":"celkových kyanidů","range":""},{"name":"snadno uvolnitelných kyanidů","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków ogólnych i łatwo uwalnialnych metodą spektrofotometryczną\nZakres:\ncyjanki ogólne\ncyjanki łatwo uwalnialne","reference":"SOP 29 (ČSN 75 7415; ČSN ISO 6703-2)","norm_bases":["SOP 29","ČSN 75 7415","ČSN ISO 6703-2"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie cyjanków ogólnych i łatwo uwalnialnych metodą spektrofotometryczną cyjanki ogólne  cyjanki łatwo uwalnialne  Vody, voda odpadní, výluhy Stanovení celkových a snadno uvolnitelných kyanidů spektrofotometricky celkových kyanidů  snadno uvolnitelných kyanidů  SOP 29 (ČSN 75 7415; ČSN ISO 6703-2) Wody, scieki, wyciagi Oznaczanie cyjankow ogolnych i latwo uwalnialnych metoda spektrofotometryczna cyjanki ogolne  cyjanki latwo uwalnialne  Vody, voda odpadni, vyluhy Stanoveni celkovych a snadno uvolnitelnych kyanidu spektrofotometricky celkovych kyanidu  snadno uvolnitelnych kyanidu  SOP 29 (CSN 75 7415; CSN ISO 6703-2)","search_en":"Waters, waste water, leachates Determination of total and easily liberatable cyanides by spectrophotometry total cyanides  easily liberatable cyanides  SOP 29 (ČSN 75 7415; ČSN ISO 6703-2)","search_zh":"水、废水、浸出液 分光光度法测定总氰化物和易释放氰化物 总氰化物  易释放氰化物  SOP 29 (ČSN 75 7415; ČSN ISO 6703-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"706f4a616fdf1034eaa0e732","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"40","test_object":"Grunt, odpad, osad","test_object_en":"Soil, waste, sludge","test_object_zh":"土壤、废物、污泥","test_object_cs":"Zemina, odpad, kal","methodology":"Oznaczanie cyjanków ogólnych i łatwo uwalnialnych metodą spektrofotometryczną","methodology_en":"Determination of total and easily liberatable cyanides by spectrophotometry","methodology_zh":"分光光度法测定总氰化物和易释放氰化物","methodology_cs":"Stanovení celkových a snadno uvolnitelných kyanidů spektrofotometricky","parameters":[{"name":"cyjanki ogólne","range":""},{"name":"cyjanki łatwo uwalnialne","range":""}],"parameters_en":[{"name":"total cyanides","range":""},{"name":"easily liberatable cyanides","range":""}],"parameters_zh":[{"name":"总氰化物","range":""},{"name":"易释放氰化物","range":""}],"parameters_cs":[{"name":"celkových kyanidů","range":""},{"name":"snadno uvolnitelných kyanidů","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków ogólnych i łatwo uwalnialnych metodą spektrofotometryczną\nZakres:\ncyjanki ogólne\ncyjanki łatwo uwalnialne","reference":"SOP 29A (DIN ISO 11262)","norm_bases":["SOP 29A","DIN ISO 11262"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Odpad – stały, ciekły, bioodpad, materiały budowlane i rozbiórkowe. Bioodpad – kompost, surowce wsadowe do kompostowania","note_en":"Waste – solid, liquid, biowaste, construction and demolition materials. Biowaste – compost, input materials for composting","note_zh":"废物 – 固体、液体、生物废物、建筑和拆除材料。生物废物 – 堆肥、堆肥原料","note_cs":"Odpad – pevný, kapalný, bioodpad, stavební a demoliční materiály. Bioodpad – kompost, vstupní suroviny do kompostů","search_text":"Grunt, odpad, osad Oznaczanie cyjanków ogólnych i łatwo uwalnialnych metodą spektrofotometryczną cyjanki ogólne  cyjanki łatwo uwalnialne  Zemina, odpad, kal Stanovení celkových a snadno uvolnitelných kyanidů spektrofotometricky celkových kyanidů  snadno uvolnitelných kyanidů  SOP 29A (DIN ISO 11262) Grunt, odpad, osad Oznaczanie cyjankow ogolnych i latwo uwalnialnych metoda spektrofotometryczna cyjanki ogolne  cyjanki latwo uwalnialne  Zemina, odpad, kal Stanoveni celkovych a snadno uvolnitelnych kyanidu spektrofotometricky celkovych kyanidu  snadno uvolnitelnych kyanidu  SOP 29A (DIN ISO 11262)","search_en":"Soil, waste, sludge Determination of total and easily liberatable cyanides by spectrophotometry total cyanides  easily liberatable cyanides  SOP 29A (DIN ISO 11262)","search_zh":"土壤、废物、污泥 分光光度法测定总氰化物和易释放氰化物 总氰化物  易释放氰化物  SOP 29A (DIN ISO 11262)","categories":["environment","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a797072375bca6559c91b706","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"41","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","methodology_en":"Determination of monohydric phenols by spectrophotometry","methodology_zh":"分光光度法测定一元酚","methodology_cs":"Stanovení jednosytných fenolů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","reference":"SOP 30 (ČSN ISO 6439)","norm_bases":["SOP 30","ČSN ISO 6439"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną Vody, voda odpadní, výluhy Stanovení jednosytných fenolů spektrofotometricky SOP 30 (ČSN ISO 6439) Wody, scieki, wyciagi Oznaczanie fenoli jednowodorotlenowych metoda spektrofotometryczna Vody, voda odpadni, vyluhy Stanoveni jednosytnych fenolu spektrofotometricky SOP 30 (CSN ISO 6439)","search_en":"Waters, waste water, leachates Determination of monohydric phenols by spectrophotometry SOP 30 (ČSN ISO 6439)","search_zh":"水、废水、浸出液 分光光度法测定一元酚 SOP 30 (ČSN ISO 6439)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"02f5670459a136be13505017","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"42","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną komercyjnym zestawem analitycznym","methodology_en":"Determination of monohydric phenols by spectrophotometry using a commercial analytical kit","methodology_zh":"使用商品化分析试剂盒分光光度法测定一元酚","methodology_cs":"Stanovení jednosytných fenolů spektrofotometricky analytickou komerční soupravou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną komercyjnym zestawem analitycznym","reference":"SOP 30A (návod firmy HACH)","norm_bases":["SOP 30A","návod firmy HACH"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną komercyjnym zestawem analitycznym Vody, voda odpadní, výluhy Stanovení jednosytných fenolů spektrofotometricky analytickou komerční soupravou SOP 30A (návod firmy HACH) Wody, scieki, wyciagi Oznaczanie fenoli jednowodorotlenowych metoda spektrofotometryczna komercyjnym zestawem analitycznym Vody, voda odpadni, vyluhy Stanoveni jednosytnych fenolu spektrofotometricky analytickou komercni soupravou SOP 30A (navod firmy HACH)","search_en":"Waters, waste water, leachates Determination of monohydric phenols by spectrophotometry using a commercial analytical kit SOP 30A (návod firmy HACH)","search_zh":"水、废水、浸出液 使用商品化分析试剂盒分光光度法测定一元酚 SOP 30A (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b92b6dd8653f8eda40193f72","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"43","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metodą spektrofotometryczną","methodology_en":"Determination of anionic surfactants (MBAS) by spectrophotometry","methodology_zh":"分光光度法测定阴离子表面活性剂（MBAS）","methodology_cs":"Stanovení aniontových tenzidů (PAL-A) spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metodą spektrofotometryczną","reference":"SOP 31 (ČSN EN 903)","norm_bases":["SOP 31","ČSN EN 903"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metodą spektrofotometryczną Vody, voda odpadní, výluhy Stanovení aniontových tenzidů (PAL-A) spektrofotometricky SOP 31 (ČSN EN 903) Wody, scieki, wyciagi Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metoda spektrofotometryczna Vody, voda odpadni, vyluhy Stanoveni aniontovych tenzidu (PAL-A) spektrofotometricky SOP 31 (CSN EN 903)","search_en":"Waters, waste water, leachates Determination of anionic surfactants (MBAS) by spectrophotometry SOP 31 (ČSN EN 903)","search_zh":"水、废水、浸出液 分光光度法测定阴离子表面活性剂（MBAS） SOP 31 (ČSN EN 903)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2b5d7790683ca529ff4c0c23","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"44","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metodą spektrofotometryczną komercyjnym zestawem analitycznym","methodology_en":"Determination of anionic surfactants (MBAS) by spectrophotometry using a commercial analytical kit","methodology_zh":"使用商品化分析试剂盒分光光度法测定阴离子表面活性剂（MBAS）","methodology_cs":"Stanovení aniontových tenzidů (PAL-A) spektrofotometricky analytickou komerční soupravou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metodą spektrofotometryczną komercyjnym zestawem analitycznym","reference":"SOP 31A (návod firmy HACH)","norm_bases":["SOP 31A","návod firmy HACH"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metodą spektrofotometryczną komercyjnym zestawem analitycznym Vody, voda odpadní, výluhy Stanovení aniontových tenzidů (PAL-A) spektrofotometricky analytickou komerční soupravou SOP 31A (návod firmy HACH) Wody, scieki, wyciagi Oznaczanie anionowych substancji powierzchniowo czynnych (PAL-A) metoda spektrofotometryczna komercyjnym zestawem analitycznym Vody, voda odpadni, vyluhy Stanoveni aniontovych tenzidu (PAL-A) spektrofotometricky analytickou komercni soupravou SOP 31A (navod firmy HACH)","search_en":"Waters, waste water, leachates Determination of anionic surfactants (MBAS) by spectrophotometry using a commercial analytical kit SOP 31A (návod firmy HACH)","search_zh":"水、废水、浸出液 使用商品化分析试剂盒分光光度法测定阴离子表面活性剂（MBAS） SOP 31A (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2f251ddb02a4a3ec3a55e3ac","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"45","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","reference":"SOP 60 (ČSN EN ISO 9562)","norm_bases":["SOP 60","ČSN EN ISO 9562"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną Vody, voda odpadní, výluhy Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky SOP 60 (ČSN EN ISO 9562) Wody, scieki, wyciagi Oznaczanie adsorbowalnych zwiazkow chloroorganicznych (AOX) metoda kulometryczna Vody, voda odpadni, vyluhy Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky SOP 60 (CSN EN ISO 9562)","search_en":"Waters, waste water, leachates Determination of adsorbable organically bound halogens (AOX) by coulometry SOP 60 (ČSN EN ISO 9562)","search_zh":"水、废水、浸出液 库仑法测定可吸附有机卤素（AOX） SOP 60 (ČSN EN ISO 9562)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4e2fc88dca7c66147f2ecdf0","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"46","test_object":"Grunt, odpad, osad, osad denny","test_object_en":"Soil, waste, sludge, sediment","test_object_zh":"土壤、废物、污泥、沉积物","test_object_cs":"Zemina, odpad, kal, sediment","methodology":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","reference":"SOP 60A (ČSN EN 16166)","norm_bases":["SOP 60A","ČSN EN 16166"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Odpad – stały, ciekły, bioodpad, materiały budowlane i rozbiórkowe. Bioodpad – kompost, surowce wsadowe do kompostowania","note_en":"Waste – solid, liquid, biowaste, construction and demolition materials. Biowaste – compost, input materials for composting","note_zh":"废物 – 固体、液体、生物废物、建筑和拆除材料。生物废物 – 堆肥、堆肥原料","note_cs":"Odpad – pevný, kapalný, bioodpad, stavební a demoliční materiály. Bioodpad – kompost, vstupní suroviny do kompostů","search_text":"Grunt, odpad, osad, osad denny Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną Zemina, odpad, kal, sediment Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky SOP 60A (ČSN EN 16166) Grunt, odpad, osad, osad denny Oznaczanie adsorbowalnych zwiazkow chloroorganicznych (AOX) metoda kulometryczna Zemina, odpad, kal, sediment Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky SOP 60A (CSN EN 16166)","search_en":"Soil, waste, sludge, sediment Determination of adsorbable organically bound halogens (AOX) by coulometry SOP 60A (ČSN EN 16166)","search_zh":"土壤、废物、污泥、沉积物 库仑法测定可吸附有机卤素（AOX） SOP 60A (ČSN EN 16166)","categories":["environment","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ffba0f986785cdc470c46835","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"47","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie anionów metodą elektroforezy kapilarnej z detekcją spektrofotometryczną","methodology_en":"Determination of anions by capillary electrophoresis with spectrophotometric detection","methodology_zh":"毛细管电泳-分光光度检测法测定阴离子","methodology_cs":"Stanovení aniontů metodou kapilární elektroforézy se spektrofotometrickou detekcí","parameters":[{"name":"chlorki (Cl-)","range":""},{"name":"azotany (NO3-)","range":""},{"name":"azotyny (NO2-)","range":""},{"name":"fluorki (F-)","range":""},{"name":"siarczany (SO42-)","range":""},{"name":"fosforany (PO43-)","range":""}],"parameters_en":[{"name":"chlorides (Cl-)","range":""},{"name":"nitrates (NO3-)","range":""},{"name":"nitrites (NO2-)","range":""},{"name":"fluorides (F-)","range":""},{"name":"sulphates (SO42-)","range":""},{"name":"phosphates (PO43-)","range":""}],"parameters_zh":[{"name":"氯化物（Cl-）","range":""},{"name":"硝酸盐（NO3-）","range":""},{"name":"亚硝酸盐（NO2-）","range":""},{"name":"氟化物（F-）","range":""},{"name":"硫酸盐（SO42-）","range":""},{"name":"磷酸盐（PO43-）","range":""}],"parameters_cs":[{"name":"chloridy (Cl-)","range":""},{"name":"dusičnany (NO3-)","range":""},{"name":"dusitany (NO2-)","range":""},{"name":"fluoridy (F-)","range":""},{"name":"sírany (SO42-)","range":""},{"name":"fosforečnany (PO43-)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot azotanowy (N-NO3-)","azot azotynowy (N-NO2-)","azot nieorganiczny"],"computed_en":["nitrate nitrogen (N-NO3-)","nitrite nitrogen (N-NO2-)","inorganic nitrogen"],"computed_zh":["硝酸盐氮（N-NO3-）","亚硝酸盐氮（N-NO2-）","无机氮"],"computed_cs":["dusičnanový dusík (N-NO3-)","dusitanový dusík (N-NO2-)","anorganický dusík (Nanorg)"],"activity":"Oznaczanie anionów metodą elektroforezy kapilarnej z detekcją spektrofotometryczną\nZakres:\nchlorki (Cl-)\nazotany (NO3-)\nazotyny (NO2-)\nfluorki (F-)\nsiarczany (SO42-)\nfosforany (PO43-)","reference":"SOP 66 (manuál firmy Lumex)","norm_bases":["SOP 66","manuál firmy Lumex"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie anionów metodą elektroforezy kapilarnej z detekcją spektrofotometryczną chlorki (Cl-)  azotany (NO3-)  azotyny (NO2-)  fluorki (F-)  siarczany (SO42-)  fosforany (PO43-)  azot azotanowy (N-NO3-) azot azotynowy (N-NO2-) azot nieorganiczny Vody, voda odpadní, výluhy Stanovení aniontů metodou kapilární elektroforézy se spektrofotometrickou detekcí chloridy (Cl-)  dusičnany (NO3-)  dusitany (NO2-)  fluoridy (F-)  sírany (SO42-)  fosforečnany (PO43-)  dusičnanový dusík (N-NO3-) dusitanový dusík (N-NO2-) anorganický dusík (Nanorg) SOP 66 (manuál firmy Lumex) Wody, scieki, wyciagi Oznaczanie anionow metoda elektroforezy kapilarnej z detekcja spektrofotometryczna chlorki (Cl-)  azotany (NO3-)  azotyny (NO2-)  fluorki (F-)  siarczany (SO42-)  fosforany (PO43-)  azot azotanowy (N-NO3-) azot azotynowy (N-NO2-) azot nieorganiczny Vody, voda odpadni, vyluhy Stanoveni aniontu metodou kapilarni elektroforezy se spektrofotometrickou detekci chloridy (Cl-)  dusicnany (NO3-)  dusitany (NO2-)  fluoridy (F-)  sirany (SO42-)  fosforecnany (PO43-)  dusicnanovy dusik (N-NO3-) dusitanovy dusik (N-NO2-) anorganicky dusik (Nanorg) SOP 66 (manual firmy Lumex)","search_en":"Waters, waste water, leachates Determination of anions by capillary electrophoresis with spectrophotometric detection chlorides (Cl-)  nitrates (NO3-)  nitrites (NO2-)  fluorides (F-)  sulphates (SO42-)  phosphates (PO43-)  nitrate nitrogen (N-NO3-) nitrite nitrogen (N-NO2-) inorganic nitrogen SOP 66 (manuál firmy Lumex)","search_zh":"水、废水、浸出液 毛细管电泳-分光光度检测法测定阴离子 氯化物（Cl-）  硝酸盐（NO3-）  亚硝酸盐（NO2-）  氟化物（F-）  硫酸盐（SO42-）  磷酸盐（PO43-）  硝酸盐氮（N-NO3-） 亚硝酸盐氮（N-NO2-） 无机氮 SOP 66 (manuál firmy Lumex)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8c6538d282b326252b02924c","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"48","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie ogólnego węgla organicznego (TOC) i rozpuszczonego węgla organicznego (DOC) metodą spektrometrii w podczerwieni","methodology_en":"Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by infrared spectrometry","methodology_zh":"红外光谱法测定总有机碳（TOC）和溶解性有机碳（DOC）","methodology_cs":"Stanovení celkového organického uhlíku (TOC) a rozpuštěného organického uhlíku (DOC) metodou infračervené spektrometrie","parameters":[{"name":"ogólny węgiel organiczny (TOC)","range":""},{"name":"rozpuszczony węgiel organiczny (DOC)","range":""}],"parameters_en":[{"name":"total organic carbon (TOC)","range":""},{"name":"dissolved organic carbon (DOC)","range":""}],"parameters_zh":[{"name":"总有机碳（TOC）","range":""},{"name":"溶解性有机碳（DOC）","range":""}],"parameters_cs":[{"name":"celkového organického uhlíku (TOC)","range":""},{"name":"rozpuštěného organického uhlíku (DOC)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnego węgla organicznego (TOC) i rozpuszczonego węgla organicznego (DOC) metodą spektrometrii w podczerwieni\nZakres:\nogólny węgiel organiczny (TOC)\nrozpuszczony węgiel organiczny (DOC)","reference":"SOP 65 (ČSN EN 1484)","norm_bases":["SOP 65","ČSN EN 1484"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie ogólnego węgla organicznego (TOC) i rozpuszczonego węgla organicznego (DOC) metodą spektrometrii w podczerwieni ogólny węgiel organiczny (TOC)  rozpuszczony węgiel organiczny (DOC)  Vody, voda odpadní, výluhy Stanovení celkového organického uhlíku (TOC) a rozpuštěného organického uhlíku (DOC) metodou infračervené spektrometrie celkového organického uhlíku (TOC)  rozpuštěného organického uhlíku (DOC)  SOP 65 (ČSN EN 1484) Wody, scieki, wyciagi Oznaczanie ogolnego wegla organicznego (TOC) i rozpuszczonego wegla organicznego (DOC) metoda spektrometrii w podczerwieni ogolny wegiel organiczny (TOC)  rozpuszczony wegiel organiczny (DOC)  Vody, voda odpadni, vyluhy Stanoveni celkoveho organickeho uhliku (TOC) a rozpusteneho organickeho uhliku (DOC) metodou infracervene spektrometrie celkoveho organickeho uhliku (TOC)  rozpusteneho organickeho uhliku (DOC)  SOP 65 (CSN EN 1484)","search_en":"Waters, waste water, leachates Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by infrared spectrometry total organic carbon (TOC)  dissolved organic carbon (DOC)  SOP 65 (ČSN EN 1484)","search_zh":"水、废水、浸出液 红外光谱法测定总有机碳（TOC）和溶解性有机碳（DOC） 总有机碳（TOC）  溶解性有机碳（DOC）  SOP 65 (ČSN EN 1484)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af34985602a27b5fc55f8128","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"49","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie substancji ekstrahujących się (EL) metodą wagową","methodology_en":"Determination of extractable substances (ES) by gravimetry","methodology_zh":"重量法测定可萃取物（ES）","methodology_cs":"Stanovení extrahovatelných látek (EL) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji ekstrahujących się (EL) metodą wagową","reference":"SOP 62 (ČSN 75 7508)","norm_bases":["SOP 62","ČSN 75 7508"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie substancji ekstrahujących się (EL) metodą wagową Vody, voda odpadní Stanovení extrahovatelných látek (EL) gravimetricky SOP 62 (ČSN 75 7508) Wody, scieki Oznaczanie substancji ekstrahujacych sie (EL) metoda wagowa Vody, voda odpadni Stanoveni extrahovatelnych latek (EL) gravimetricky SOP 62 (CSN 75 7508)","search_en":"Waters, waste water Determination of extractable substances (ES) by gravimetry SOP 62 (ČSN 75 7508)","search_zh":"水、废水 重量法测定可萃取物（ES） SOP 62 (ČSN 75 7508)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e872ff29d679eeffbb500489","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"50","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie tłuszczów i olejów metodą wagową","methodology_en":"Determination of fats and oils by gravimetry","methodology_zh":"重量法测定油脂","methodology_cs":"Stanovení tuků a olejů gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tłuszczów i olejów metodą wagową","reference":"SOP 64 (ČSN 75 7509)","norm_bases":["SOP 64","ČSN 75 7509"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie tłuszczów i olejów metodą wagową Vody, voda odpadní Stanovení tuků a olejů gravimetricky SOP 64 (ČSN 75 7509) Wody, scieki Oznaczanie tluszczow i olejow metoda wagowa Vody, voda odpadni Stanoveni tuku a oleju gravimetricky SOP 64 (CSN 75 7509)","search_en":"Waters, waste water Determination of fats and oils by gravimetry SOP 64 (ČSN 75 7509)","search_zh":"水、废水 重量法测定油脂 SOP 64 (ČSN 75 7509)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"57072af107330ed81efc9dad","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"51","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"SOP 47 (ČSN 75 7342)","norm_bases":["SOP 47","ČSN 75 7342"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie temperatury Vody, voda odpadní Stanovení teploty SOP 47 (ČSN 75 7342) Wody, scieki Oznaczanie temperatury Vody, voda odpadni Stanoveni teploty SOP 47 (CSN 75 7342)","search_en":"Waters, waste water Determination of temperature SOP 47 (ČSN 75 7342)","search_zh":"水、废水 温度测定 SOP 47 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"527d262bce6913009194a66f","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"52","test_object":"Woda pitna, wyprodukowana, uzdatniona, woda w kąpieliskach","test_object_en":"Drinking, produced, treated water, bathing water","test_object_zh":"饮用水、制备水、处理水、游泳用水","test_object_cs":"Voda pitná, vyrobená, upravená, voda ke koupání","methodology":"Oznaczanie chloru wolnego, związanego i całkowitego metodą spektrofotometryczną komercyjnym zestawem analitycznym","methodology_en":"Determination of free, combined and total chlorine by spectrophotometry using a commercial analytical kit","methodology_zh":"使用商品化分析试剂盒分光光度法测定游离氯、化合氯和总氯","methodology_cs":"Stanovení volného, vázaného a celkového chloru spektrofotometricky analytickou komerční soupravou","parameters":[{"name":"chlor wolny","range":""},{"name":"chlor związany","range":""},{"name":"chlor całkowity","range":""}],"parameters_en":[{"name":"free chlorine","range":""},{"name":"combined chlorine","range":""},{"name":"total chlorine","range":""}],"parameters_zh":[{"name":"游离氯","range":""},{"name":"化合氯","range":""},{"name":"总氯","range":""}],"parameters_cs":[{"name":"volného chloru","range":""},{"name":"vázaného chloru","range":""},{"name":"celkového chloru","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chloru wolnego, związanego i całkowitego metodą spektrofotometryczną komercyjnym zestawem analitycznym\nZakres:\nchlor wolny\nchlor związany\nchlor całkowity","reference":"SOP 48 (ČSN EN ISO 7393-2; návod firmy HACH)","norm_bases":["SOP 48","ČSN EN ISO 7393-2","návod firmy HACH"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, wyprodukowana, uzdatniona, woda w kąpieliskach Oznaczanie chloru wolnego, związanego i całkowitego metodą spektrofotometryczną komercyjnym zestawem analitycznym chlor wolny  chlor związany  chlor całkowity  Voda pitná, vyrobená, upravená, voda ke koupání Stanovení volného, vázaného a celkového chloru spektrofotometricky analytickou komerční soupravou volného chloru  vázaného chloru  celkového chloru  SOP 48 (ČSN EN ISO 7393-2; návod firmy HACH) Woda pitna, wyprodukowana, uzdatniona, woda w kapieliskach Oznaczanie chloru wolnego, zwiazanego i calkowitego metoda spektrofotometryczna komercyjnym zestawem analitycznym chlor wolny  chlor zwiazany  chlor calkowity  Voda pitna, vyrobena, upravena, voda ke koupani Stanoveni volneho, vazaneho a celkoveho chloru spektrofotometricky analytickou komercni soupravou volneho chloru  vazaneho chloru  celkoveho chloru  SOP 48 (CSN EN ISO 7393-2; navod firmy HACH)","search_en":"Drinking, produced, treated water, bathing water Determination of free, combined and total chlorine by spectrophotometry using a commercial analytical kit free chlorine  combined chlorine  total chlorine  SOP 48 (ČSN EN ISO 7393-2; návod firmy HACH)","search_zh":"饮用水、制备水、处理水、游泳用水 使用商品化分析试剂盒分光光度法测定游离氯、化合氯和总氯 游离氯  化合氯  总氯  SOP 48 (ČSN EN ISO 7393-2; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"96f4d3eb0b6bc90f0e3e5401","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"53","test_object":"Woda w kąpieliskach","test_object_en":"Bathing water","test_object_zh":"游泳用水","test_object_cs":"Voda ke koupání","methodology":"Oznaczanie przezroczystości – metoda orientacyjnej analizy sensorycznej","methodology_en":"Determination of transparency – indicative sensory analysis method","methodology_zh":"透明度测定 – 初步感官分析法","methodology_cs":"Stanovení průhlednosti – metoda orientační senzorické analýzy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przezroczystości – metoda orientacyjnej analizy sensorycznej","reference":"SOP 49C (ČSN 75 7340)","norm_bases":["SOP 49C","ČSN 75 7340"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda w kąpieliskach Oznaczanie przezroczystości – metoda orientacyjnej analizy sensorycznej Voda ke koupání Stanovení průhlednosti – metoda orientační senzorické analýzy SOP 49C (ČSN 75 7340) Woda w kapieliskach Oznaczanie przezroczystosci – metoda orientacyjnej analizy sensorycznej Voda ke koupani Stanoveni pruhlednosti – metoda orientacni senzoricke analyzy SOP 49C (CSN 75 7340)","search_en":"Bathing water Determination of transparency – indicative sensory analysis method SOP 49C (ČSN 75 7340)","search_zh":"游泳用水 透明度测定 – 初步感官分析法 SOP 49C (ČSN 75 7340)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca0271aade363fa4e94b79d7","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"54","test_object":"Woda pitna, surowa, wyprodukowana, uzdatniona","test_object_en":"Drinking, raw, produced and treated water","test_object_zh":"饮用水、原水、制备水、处理水","test_object_cs":"Voda pitná, surová, vyrobená, upravená","methodology":"Oznaczanie zapachu i smaku – metody orientacyjnej analizy sensorycznej","methodology_en":"Determination of odour and taste – indicative sensory analysis methods","methodology_zh":"气味和味道测定 – 初步感官分析法","methodology_cs":"Stanovení pachu a chuti – metody orientační senzorické analýzy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zapachu i smaku – metody orientacyjnej analizy sensorycznej","reference":"SOP 49D (ČSN 75 7340; ČSN EN 1622); SOP 49E (ČSN 75 7340; ČSN EN 1622)","norm_bases":["SOP 49D","SOP 49E","ČSN 75 7340","ČSN EN 1622"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, wyprodukowana, uzdatniona Oznaczanie zapachu i smaku – metody orientacyjnej analizy sensorycznej Voda pitná, surová, vyrobená, upravená Stanovení pachu a chuti – metody orientační senzorické analýzy SOP 49D (ČSN 75 7340; ČSN EN 1622); SOP 49E (ČSN 75 7340; ČSN EN 1622) Woda pitna, surowa, wyprodukowana, uzdatniona Oznaczanie zapachu i smaku – metody orientacyjnej analizy sensorycznej Voda pitna, surova, vyrobena, upravena Stanoveni pachu a chuti – metody orientacni senzoricke analyzy SOP 49D (CSN 75 7340; CSN EN 1622); SOP 49E (CSN 75 7340; CSN EN 1622)","search_en":"Drinking, raw, produced and treated water Determination of odour and taste – indicative sensory analysis methods SOP 49D (ČSN 75 7340; ČSN EN 1622); SOP 49E (ČSN 75 7340; ČSN EN 1622)","search_zh":"饮用水、原水、制备水、处理水 气味和味道测定 – 初步感官分析法 SOP 49D (ČSN 75 7340; ČSN EN 1622); SOP 49E (ČSN 75 7340; ČSN EN 1622)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"569ed10008a118dd18e6458b","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"55","test_object":"Woda podziemna, powierzchniowa, woda w kąpieliskach","test_object_en":"Ground water, surface water, bathing water","test_object_zh":"地下水、地表水、游泳用水","test_object_cs":"Voda podzemní, povrchová, voda ke koupání","methodology":"Oznaczanie potencjału oksydacyjno-redukcyjnego","methodology_en":"Determination of oxidation-reduction potential","methodology_zh":"氧化还原电位测定","methodology_cs":"Stanovení oxidačně redukčního potenciálu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie potencjału oksydacyjno-redukcyjnego","reference":"SOP 50 (ČSN 75 7367)","norm_bases":["SOP 50","ČSN 75 7367"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna, powierzchniowa, woda w kąpieliskach Oznaczanie potencjału oksydacyjno-redukcyjnego Voda podzemní, povrchová, voda ke koupání Stanovení oxidačně redukčního potenciálu SOP 50 (ČSN 75 7367) Woda podziemna, powierzchniowa, woda w kapieliskach Oznaczanie potencjalu oksydacyjno-redukcyjnego Voda podzemni, povrchova, voda ke koupani Stanoveni oxidacne redukcniho potencialu SOP 50 (CSN 75 7367)","search_en":"Ground water, surface water, bathing water Determination of oxidation-reduction potential SOP 50 (ČSN 75 7367)","search_zh":"地下水、地表水、游泳用水 氧化还原电位测定 SOP 50 (ČSN 75 7367)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b7082916483bea54bc3c13fc","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"56","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie bakterii mezofilnych metodą hodowlaną","methodology_en":"Determination of mesophilic bacteria by culture","methodology_zh":"培养法测定嗜温菌","methodology_cs":"Stanovení mezofilních bakterií kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii mezofilnych metodą hodowlaną","reference":"SOP 33 (ČSN 75 7841)","norm_bases":["SOP 33","ČSN 75 7841"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie bakterii mezofilnych metodą hodowlaną Vody Stanovení mezofilních bakterií kultivačně SOP 33 (ČSN 75 7841) Wody Oznaczanie bakterii mezofilnych metoda hodowlana Vody Stanoveni mezofilnich bakterii kultivacne SOP 33 (CSN 75 7841)","search_en":"Waters Determination of mesophilic bacteria by culture SOP 33 (ČSN 75 7841)","search_zh":"水 培养法测定嗜温菌 SOP 33 (ČSN 75 7841)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b4d2e9c7c166983621b617ae","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"57","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie bakterii psychrofilnych metodą hodowlaną","methodology_en":"Determination of psychrophilic bacteria by culture","methodology_zh":"培养法测定嗜冷菌","methodology_cs":"Stanovení psychrofilních bakterií kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii psychrofilnych metodą hodowlaną","reference":"SOP 34 (ČSN 75 7842)","norm_bases":["SOP 34","ČSN 75 7842"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie bakterii psychrofilnych metodą hodowlaną Vody Stanovení psychrofilních bakterií kultivačně SOP 34 (ČSN 75 7842) Wody Oznaczanie bakterii psychrofilnych metoda hodowlana Vody Stanoveni psychrofilnich bakterii kultivacne SOP 34 (CSN 75 7842)","search_en":"Waters Determination of psychrophilic bacteria by culture SOP 34 (ČSN 75 7842)","search_zh":"水 培养法测定嗜冷菌 SOP 34 (ČSN 75 7842)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"17b56ea5afbc2474429fbe1e","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"58","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","methodology_en":"Determination of intestinal enterococci by membrane filtration","methodology_zh":"膜过滤法测定肠球菌","methodology_cs":"Stanovení intestinálních enterokoků membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","reference":"SOP 37 (ČSN EN ISO 7899-2)","norm_bases":["SOP 37","ČSN EN ISO 7899-2"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie enterokoków jelitowych metodą filtracji membranowej Vody Stanovení intestinálních enterokoků membránovou filtrací SOP 37 (ČSN EN ISO 7899-2) Wody Oznaczanie enterokokow jelitowych metoda filtracji membranowej Vody Stanoveni intestinalnich enterokoku membranovou filtraci SOP 37 (CSN EN ISO 7899-2)","search_en":"Waters Determination of intestinal enterococci by membrane filtration SOP 37 (ČSN EN ISO 7899-2)","search_zh":"水 膜过滤法测定肠球菌 SOP 37 (ČSN EN ISO 7899-2)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"772c05325a6414f89ebbb549","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"59","test_object":"Woda surowa, podziemna, powierzchniowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza","test_object_en":"Raw, ground, surface, service, irrigation, industrial, boiler and heating water","test_object_zh":"原水、地下水、地表水、杂用水、灌溉水、工业用水、锅炉水、供暖水","test_object_cs":"Voda surová, podzemní, povrchová, užitková, závlahová, průmyslová, kotlová, topná","methodology":"Oznaczanie bakterii grupy coli metodą filtracji membranowej","methodology_en":"Determination of coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定大肠菌群","methodology_cs":"Stanovení koliformních bakterií membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii grupy coli metodą filtracji membranowej","reference":"SOP 42 (ČSN 75 7837)","norm_bases":["SOP 42","ČSN 75 7837"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda surowa, podziemna, powierzchniowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza Oznaczanie bakterii grupy coli metodą filtracji membranowej Voda surová, podzemní, povrchová, užitková, závlahová, průmyslová, kotlová, topná Stanovení koliformních bakterií membránovou filtrací SOP 42 (ČSN 75 7837) Woda surowa, podziemna, powierzchniowa, uzytkowa, do nawadniania, przemyslowa, kotlowa, grzewcza Oznaczanie bakterii grupy coli metoda filtracji membranowej Voda surova, podzemni, povrchova, uzitkova, zavlahova, prumyslova, kotlova, topna Stanoveni koliformnich bakterii membranovou filtraci SOP 42 (CSN 75 7837)","search_en":"Raw, ground, surface, service, irrigation, industrial, boiler and heating water Determination of coliform bacteria by membrane filtration SOP 42 (ČSN 75 7837)","search_zh":"原水、地下水、地表水、杂用水、灌溉水、工业用水、锅炉水、供暖水 膜过滤法测定大肠菌群 SOP 42 (ČSN 75 7837)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d40d25bce2ae27af2a6a7ac5","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"60","test_object":"Woda pitna, ciepła, wyprodukowana, uzdatniona, surowa, podziemna, woda w kąpieliskach","test_object_en":"Drinking, hot, produced, treated, raw and ground water, bathing water","test_object_zh":"饮用水、热水、制备水、处理水、原水、地下水、游泳用水","test_object_cs":"Voda pitná, teplá, vyrobená, upravená, surová, podzemní, voda ke koupání","methodology":"Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej","methodology_en":"Determination of Escherichia coli and coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定大肠埃希氏菌和大肠菌群","methodology_cs":"Stanovení Escherichia coli a koliformních bakterií membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej","reference":"SOP 42A (ČSN EN ISO 9308-1)","norm_bases":["SOP 42A","ČSN EN ISO 9308-1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, ciepła, wyprodukowana, uzdatniona, surowa, podziemna, woda w kąpieliskach Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej Voda pitná, teplá, vyrobená, upravená, surová, podzemní, voda ke koupání Stanovení Escherichia coli a koliformních bakterií membránovou filtrací SOP 42A (ČSN EN ISO 9308-1) Woda pitna, ciepla, wyprodukowana, uzdatniona, surowa, podziemna, woda w kapieliskach Oznaczanie Escherichia coli i bakterii grupy coli metoda filtracji membranowej Voda pitna, tepla, vyrobena, upravena, surova, podzemni, voda ke koupani Stanoveni Escherichia coli a koliformnich bakterii membranovou filtraci SOP 42A (CSN EN ISO 9308-1)","search_en":"Drinking, hot, produced, treated, raw and ground water, bathing water Determination of Escherichia coli and coliform bacteria by membrane filtration SOP 42A (ČSN EN ISO 9308-1)","search_zh":"饮用水、热水、制备水、处理水、原水、地下水、游泳用水 膜过滤法测定大肠埃希氏菌和大肠菌群 SOP 42A (ČSN EN ISO 9308-1)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3b51b7ed35cca2fd15b0ee80","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"61","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie liczby kolonii w 22 °C i 36 °C przez posiew do agarowego podłoża odżywczego","methodology_en":"Enumeration of colonies at 22 °C and 36 °C by inoculation into a nutrient agar culture medium","methodology_zh":"营养琼脂培养基接种法计数22 °C和36 °C菌落","methodology_cs":"Stanovení počtu kolonií při 22 °C a 36 °C očkováním do živného agarového kultivačního média","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby kolonii w 22 °C i 36 °C przez posiew do agarowego podłoża odżywczego","reference":"SOP 43 (ČSN EN ISO 6222)","norm_bases":["SOP 43","ČSN EN ISO 6222"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie liczby kolonii w 22 °C i 36 °C przez posiew do agarowego podłoża odżywczego Vody Stanovení počtu kolonií při 22 °C a 36 °C očkováním do živného agarového kultivačního média SOP 43 (ČSN EN ISO 6222) Wody Oznaczanie liczby kolonii w 22 °C i 36 °C przez posiew do agarowego podloza odzywczego Vody Stanoveni poctu kolonii pri 22 °C a 36 °C ockovanim do zivneho agaroveho kultivacniho media SOP 43 (CSN EN ISO 6222)","search_en":"Waters Enumeration of colonies at 22 °C and 36 °C by inoculation into a nutrient agar culture medium SOP 43 (ČSN EN ISO 6222)","search_zh":"水 营养琼脂培养基接种法计数22 °C和36 °C菌落 SOP 43 (ČSN EN ISO 6222)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bde64785f35b8baf4591bc27","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"62","test_object":"Woda pitna, ciepła, woda w kąpieliskach","test_object_en":"Drinking and hot water, bathing water","test_object_zh":"饮用水、热水、游泳用水","test_object_cs":"Voda pitná, teplá, voda ke koupání","methodology":"Oznaczanie Pseudomonas aeruginosa metodą filtracji membranowej","methodology_en":"Determination of Pseudomonas aeruginosa by membrane filtration","methodology_zh":"膜过滤法测定铜绿假单胞菌","methodology_cs":"Stanovení Pseudomonas aeruginosa membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Pseudomonas aeruginosa metodą filtracji membranowej","reference":"SOP 35 (ČSN EN ISO 16266)","norm_bases":["SOP 35","ČSN EN ISO 16266"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, ciepła, woda w kąpieliskach Oznaczanie Pseudomonas aeruginosa metodą filtracji membranowej Voda pitná, teplá, voda ke koupání Stanovení Pseudomonas aeruginosa membránovou filtrací SOP 35 (ČSN EN ISO 16266) Woda pitna, ciepla, woda w kapieliskach Oznaczanie Pseudomonas aeruginosa metoda filtracji membranowej Voda pitna, tepla, voda ke koupani Stanoveni Pseudomonas aeruginosa membranovou filtraci SOP 35 (CSN EN ISO 16266)","search_en":"Drinking and hot water, bathing water Determination of Pseudomonas aeruginosa by membrane filtration SOP 35 (ČSN EN ISO 16266)","search_zh":"饮用水、热水、游泳用水 膜过滤法测定铜绿假单胞菌 SOP 35 (ČSN EN ISO 16266)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a49fa11088602865b6687995","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"63","test_object":"Woda pitna, ciepła, woda w kąpieliskach","test_object_en":"Drinking and hot water, bathing water","test_object_zh":"饮用水、热水、游泳用水","test_object_cs":"Voda pitná, teplá, voda ke koupání","methodology":"Oznaczanie Staphylococcus aureus metodą filtracji membranowej","methodology_en":"Determination of Staphylococcus aureus by membrane filtration","methodology_zh":"膜过滤法测定金黄色葡萄球菌","methodology_cs":"Stanovení Staphylococcus aureus membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Staphylococcus aureus metodą filtracji membranowej","reference":"SOP 36 (ČSN EN ISO 6888-1)","norm_bases":["SOP 36","ČSN EN ISO 6888-1"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, ciepła, woda w kąpieliskach Oznaczanie Staphylococcus aureus metodą filtracji membranowej Voda pitná, teplá, voda ke koupání Stanovení Staphylococcus aureus membránovou filtrací SOP 36 (ČSN EN ISO 6888-1) Woda pitna, ciepla, woda w kapieliskach Oznaczanie Staphylococcus aureus metoda filtracji membranowej Voda pitna, tepla, voda ke koupani Stanoveni Staphylococcus aureus membranovou filtraci SOP 36 (CSN EN ISO 6888-1)","search_en":"Drinking and hot water, bathing water Determination of Staphylococcus aureus by membrane filtration SOP 36 (ČSN EN ISO 6888-1)","search_zh":"饮用水、热水、游泳用水 膜过滤法测定金黄色葡萄球菌 SOP 36 (ČSN EN ISO 6888-1)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0902e6d0c657aa307427a045","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"64","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie bakterii z rodzaju Legionella metodą filtracji membranowej","methodology_en":"Determination of Legionella bacteria by membrane filtration","methodology_zh":"膜过滤法测定军团菌属细菌","methodology_cs":"Stanovení bakterií rodu Legionella membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii z rodzaju Legionella metodą filtracji membranowej","reference":"SOP 38 (ČSN EN ISO 11731)","norm_bases":["SOP 38","ČSN EN ISO 11731"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie bakterii z rodzaju Legionella metodą filtracji membranowej Vody Stanovení bakterií rodu Legionella membránovou filtrací SOP 38 (ČSN EN ISO 11731) Wody Oznaczanie bakterii z rodzaju Legionella metoda filtracji membranowej Vody Stanoveni bakterii rodu Legionella membranovou filtraci SOP 38 (CSN EN ISO 11731)","search_en":"Waters Determination of Legionella bacteria by membrane filtration SOP 38 (ČSN EN ISO 11731)","search_zh":"水 膜过滤法测定军团菌属细菌 SOP 38 (ČSN EN ISO 11731)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bbdf0171ac5d848fae3a4f4","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"65","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie biosestonu metodą mikroskopową","methodology_en":"Determination of bioseston by microscopy","methodology_zh":"显微镜法测定生物悬浮物","methodology_cs":"Stanovení biosestonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biosestonu metodą mikroskopową","reference":"SOP 39 (ČSN 75 7712)","norm_bases":["SOP 39","ČSN 75 7712"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie biosestonu metodą mikroskopową Vody Stanovení biosestonu mikroskopicky SOP 39 (ČSN 75 7712) Wody Oznaczanie biosestonu metoda mikroskopowa Vody Stanoveni biosestonu mikroskopicky SOP 39 (CSN 75 7712)","search_en":"Waters Determination of bioseston by microscopy SOP 39 (ČSN 75 7712)","search_zh":"水 显微镜法测定生物悬浮物 SOP 39 (ČSN 75 7712)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a2d3f426978c31e411bf16a5","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"66","test_object":"Wody","test_object_en":"Waters","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie abiosestonu metodą mikroskopową","methodology_en":"Determination of abioseston by microscopy","methodology_zh":"显微镜法测定非生物悬浮物","methodology_cs":"Stanovení abiosestonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie abiosestonu metodą mikroskopową","reference":"SOP 40 (ČSN 75 7713)","norm_bases":["SOP 40","ČSN 75 7713"],"lab_section":"Laboratorium Metod Podstawowych","lab_section_en":"Laboratory of Basic Methods","lab_section_zh":"基础方法实验室","lab_section_cs":"Laboratoř základních metod","lab_address":"Třebíčská 1540, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody Oznaczanie abiosestonu metodą mikroskopową Vody Stanovení abiosestonu mikroskopicky SOP 40 (ČSN 75 7713) Wody Oznaczanie abiosestonu metoda mikroskopowa Vody Stanoveni abiosestonu mikroskopicky SOP 40 (CSN 75 7713)","search_en":"Waters Determination of abioseston by microscopy SOP 40 (ČSN 75 7713)","search_zh":"水 显微镜法测定非生物悬浮物 SOP 40 (ČSN 75 7713)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"681d48ff5fefe5a0cd9446ec","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"1","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie lotnych związków organicznych (VOC) metodą chromatografii gazowej z detektorem ECD, FID i obliczanie sum lotnych związków organicznych z wyników pomiarów","methodology_en":"Determination of volatile organic compounds (VOC) by gas chromatography with ECD and FID detectors and calculation of sums of volatile organic compounds from measured values","methodology_zh":"气相色谱（ECD、FID检测器）测定挥发性有机物（VOC），由测得值计算挥发性有机物总量","methodology_cs":"Stanovení volatilních organických látek (VOC) metodou plynové chromatografie s detektorem ECD, FID a výpočet sum volatilních organických látek z naměřených hodnot","parameters":[{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"etylobenzen","range":""},{"name":"m,o,p-ksylen","range":""},{"name":"chlorobenzen","range":""},{"name":"1,2-dichlorobenzen","range":""},{"name":"1,3-dichlorobenzen","range":""},{"name":"1,4-dichlorobenzen","range":""},{"name":"1,1-dichloroeten","range":""},{"name":"trans-1,2-dichloroeten","range":""},{"name":"1,1-dichloroetan","range":""},{"name":"cis-1,2-dichloroeten","range":""},{"name":"chloroform","range":""},{"name":"1,1,1-trichloroetan","range":""},{"name":"1,1,2-trichloroetan","range":""},{"name":"tetrachlorometan","range":""},{"name":"1,2-dichloroetan","range":""},{"name":"trichloroeten","range":""},{"name":"bromodichlorometan","range":""},{"name":"dibromochlorometan","range":""},{"name":"tribromometan (bromoform)","range":""},{"name":"tetrachloroeten","range":""},{"name":"1,1,2,2-tetrachloroetan","range":""}],"parameters_en":[{"name":"benzene","range":""},{"name":"toluene","range":""},{"name":"ethylbenzene","range":""},{"name":"m,o,p-xylene","range":""},{"name":"chlorobenzene","range":""},{"name":"1,2-dichlorobenzene","range":""},{"name":"1,3-dichlorobenzene","range":""},{"name":"1,4-dichlorobenzene","range":""},{"name":"1,1-dichloroethene","range":""},{"name":"trans-1,2-dichloroethene","range":""},{"name":"1,1-dichloroethane","range":""},{"name":"cis-1,2-dichloroethene","range":""},{"name":"chloroform","range":""},{"name":"1,1,1-trichloroethane","range":""},{"name":"1,1,2-trichloroethane","range":""},{"name":"tetrachloromethane","range":""},{"name":"1,2-dichloroethane","range":""},{"name":"trichloroethene","range":""},{"name":"bromodichloromethane","range":""},{"name":"dibromochloromethane","range":""},{"name":"tribromomethane (bromoform)","range":""},{"name":"tetrachloroethene","range":""},{"name":"1,1,2,2-tetrachloroethane","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"乙苯","range":""},{"name":"间、邻、对二甲苯","range":""},{"name":"氯苯","range":""},{"name":"1,2-二氯苯","range":""},{"name":"1,3-二氯苯","range":""},{"name":"1,4-二氯苯","range":""},{"name":"1,1-二氯乙烯","range":""},{"name":"反-1,2-二氯乙烯","range":""},{"name":"1,1-二氯乙烷","range":""},{"name":"顺-1,2-二氯乙烯","range":""},{"name":"氯仿","range":""},{"name":"1,1,1-三氯乙烷","range":""},{"name":"1,1,2-三氯乙烷","range":""},{"name":"四氯化碳","range":""},{"name":"1,2-二氯乙烷","range":""},{"name":"三氯乙烯","range":""},{"name":"一溴二氯甲烷","range":""},{"name":"二溴一氯甲烷","range":""},{"name":"三溴甲烷（溴仿）","range":""},{"name":"四氯乙烯","range":""},{"name":"1,1,2,2-四氯乙烷","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"ethylbenzen","range":""},{"name":"m,o,p-xylen","range":""},{"name":"chlorbenzen","range":""},{"name":"1,2-dichlorbenzen","range":""},{"name":"1,3-dichlorbenzen","range":""},{"name":"1,4-dichlorbenzen","range":""},{"name":"1,1-dichlorethen","range":""},{"name":"trans-1,2-dichlorethen","range":""},{"name":"1,1-dichlorethan","range":""},{"name":"cis-1,2-dichlorethen","range":""},{"name":"chloroform","range":""},{"name":"1,1,1-trichlorethan","range":""},{"name":"1,1,2-trichlorethan","range":""},{"name":"tetrachlormethan","range":""},{"name":"1,2-dichlorethan","range":""},{"name":"1,1,2-trichlorethen","range":""},{"name":"bromdichlormethan","range":""},{"name":"dibromchlormethan","range":""},{"name":"tribrommethan","range":""},{"name":"1,1,2,2-tetrachlorethen","range":""},{"name":"1,1,2,2-tetrachlorethan","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma trihalometanów","suma BTEX"],"computed_en":["sum of trihalomethanes","sum of BTEX"],"computed_zh":["三卤甲烷总量","BTEX总量"],"computed_cs":["suma trihalomethanů","suma BTEX"],"activity":"Oznaczanie lotnych związków organicznych (VOC) metodą chromatografii gazowej z detektorem ECD, FID i obliczanie sum lotnych związków organicznych z wyników pomiarów\nZakres:\nbenzen\ntoluen\netylobenzen\nm,o,p-ksylen\nchlorobenzen\n1,2-dichlorobenzen\n1,3-dichlorobenzen\n1,4-dichlorobenzen\n1,1-dichloroeten\ntrans-1,2-dichloroeten\n1,1-dichloroetan\ncis-1,2-dichloroeten\nchloroform\n1,1,1-trichloroetan\n1,1,2-trichloroetan\ntetrachlorometan\n1,2-dichloroetan\ntrichloroeten\nbromodichlorometan\ndibromochlorometan\ntribromometan (bromoform)\ntetrachloroeten\n1,1,2,2-tetrachloroetan","reference":"SOP 101 (ČSN EN ISO 10301; TNV 75 7552)","norm_bases":["SOP 101","ČSN EN ISO 10301","TNV 75 7552"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie lotnych związków organicznych (VOC) metodą chromatografii gazowej z detektorem ECD, FID i obliczanie sum lotnych związków organicznych z wyników pomiarów benzen  toluen  etylobenzen  m,o,p-ksylen  chlorobenzen  1,2-dichlorobenzen  1,3-dichlorobenzen  1,4-dichlorobenzen  1,1-dichloroeten  trans-1,2-dichloroeten  1,1-dichloroetan  cis-1,2-dichloroeten  chloroform  1,1,1-trichloroetan  1,1,2-trichloroetan  tetrachlorometan  1,2-dichloroetan  trichloroeten  bromodichlorometan  dibromochlorometan  tribromometan (bromoform)  tetrachloroeten  1,1,2,2-tetrachloroetan  suma trihalometanów suma BTEX Vody, voda odpadní Stanovení volatilních organických látek (VOC) metodou plynové chromatografie s detektorem ECD, FID a výpočet sum volatilních organických látek z naměřených hodnot benzen  toluen  ethylbenzen  m,o,p-xylen  chlorbenzen  1,2-dichlorbenzen  1,3-dichlorbenzen  1,4-dichlorbenzen  1,1-dichlorethen  trans-1,2-dichlorethen  1,1-dichlorethan  cis-1,2-dichlorethen  chloroform  1,1,1-trichlorethan  1,1,2-trichlorethan  tetrachlormethan  1,2-dichlorethan  1,1,2-trichlorethen  bromdichlormethan  dibromchlormethan  tribrommethan  1,1,2,2-tetrachlorethen  1,1,2,2-tetrachlorethan  suma trihalomethanů suma BTEX SOP 101 (ČSN EN ISO 10301; TNV 75 7552) Wody, scieki Oznaczanie lotnych zwiazkow organicznych (VOC) metoda chromatografii gazowej z detektorem ECD, FID i obliczanie sum lotnych zwiazkow organicznych z wynikow pomiarow benzen  toluen  etylobenzen  m,o,p-ksylen  chlorobenzen  1,2-dichlorobenzen  1,3-dichlorobenzen  1,4-dichlorobenzen  1,1-dichloroeten  trans-1,2-dichloroeten  1,1-dichloroetan  cis-1,2-dichloroeten  chloroform  1,1,1-trichloroetan  1,1,2-trichloroetan  tetrachlorometan  1,2-dichloroetan  trichloroeten  bromodichlorometan  dibromochlorometan  tribromometan (bromoform)  tetrachloroeten  1,1,2,2-tetrachloroetan  suma trihalometanow suma BTEX Vody, voda odpadni Stanoveni volatilnich organickych latek (VOC) metodou plynove chromatografie s detektorem ECD, FID a vypocet sum volatilnich organickych latek z namerenych hodnot benzen  toluen  ethylbenzen  m,o,p-xylen  chlorbenzen  1,2-dichlorbenzen  1,3-dichlorbenzen  1,4-dichlorbenzen  1,1-dichlorethen  trans-1,2-dichlorethen  1,1-dichlorethan  cis-1,2-dichlorethen  chloroform  1,1,1-trichlorethan  1,1,2-trichlorethan  tetrachlormethan  1,2-dichlorethan  1,1,2-trichlorethen  bromdichlormethan  dibromchlormethan  tribrommethan  1,1,2,2-tetrachlorethen  1,1,2,2-tetrachlorethan  suma trihalomethanu suma BTEX SOP 101 (CSN EN ISO 10301; TNV 75 7552)","search_en":"Waters, waste water Determination of volatile organic compounds (VOC) by gas chromatography with ECD and FID detectors and calculation of sums of volatile organic compounds from measured values benzene  toluene  ethylbenzene  m,o,p-xylene  chlorobenzene  1,2-dichlorobenzene  1,3-dichlorobenzene  1,4-dichlorobenzene  1,1-dichloroethene  trans-1,2-dichloroethene  1,1-dichloroethane  cis-1,2-dichloroethene  chloroform  1,1,1-trichloroethane  1,1,2-trichloroethane  tetrachloromethane  1,2-dichloroethane  trichloroethene  bromodichloromethane  dibromochloromethane  tribromomethane (bromoform)  tetrachloroethene  1,1,2,2-tetrachloroethane  sum of trihalomethanes sum of BTEX SOP 101 (ČSN EN ISO 10301; TNV 75 7552)","search_zh":"水、废水 气相色谱（ECD、FID检测器）测定挥发性有机物（VOC），由测得值计算挥发性有机物总量 苯  甲苯  乙苯  间、邻、对二甲苯  氯苯  1,2-二氯苯  1,3-二氯苯  1,4-二氯苯  1,1-二氯乙烯  反-1,2-二氯乙烯  1,1-二氯乙烷  顺-1,2-二氯乙烯  氯仿  1,1,1-三氯乙烷  1,1,2-三氯乙烷  四氯化碳  1,2-二氯乙烷  三氯乙烯  一溴二氯甲烷  二溴一氯甲烷  三溴甲烷（溴仿）  四氯乙烯  1,1,2,2-四氯乙烷  三卤甲烷总量 BTEX总量 SOP 101 (ČSN EN ISO 10301; TNV 75 7552)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"664c6d91a0b0120934c0bb12","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"2","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie węglowodorów C10-C40 metodą chromatografii gazowej z detektorem FID","methodology_en":"Determination of hydrocarbons C10-C40 by gas chromatography with FID detector","methodology_zh":"气相色谱-FID法测定C10-C40烃类","methodology_cs":"Stanovení uhlovodíků C10-C40 metodou plynové chromatografie s detektorem FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10-C40 metodą chromatografii gazowej z detektorem FID","reference":"SOP 102 (ČSN EN ISO 9377-2)","norm_bases":["SOP 102","ČSN EN ISO 9377-2"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie węglowodorów C10-C40 metodą chromatografii gazowej z detektorem FID Vody, voda odpadní Stanovení uhlovodíků C10-C40 metodou plynové chromatografie s detektorem FID SOP 102 (ČSN EN ISO 9377-2) Wody, scieki Oznaczanie weglowodorow C10-C40 metoda chromatografii gazowej z detektorem FID Vody, voda odpadni Stanoveni uhlovodiku C10-C40 metodou plynove chromatografie s detektorem FID SOP 102 (CSN EN ISO 9377-2)","search_en":"Waters, waste water Determination of hydrocarbons C10-C40 by gas chromatography with FID detector SOP 102 (ČSN EN ISO 9377-2)","search_zh":"水、废水 气相色谱-FID法测定C10-C40烃类 SOP 102 (ČSN EN ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8cd8f0c464fbce705e78126e","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"3","test_object":"Grunt, odpad stały, osad, osad denny","test_object_en":"Soil, solid waste, sludge, sediment","test_object_zh":"土壤、固体废物、污泥、沉积物","test_object_cs":"Zemina, pevný odpad, kal, sediment","methodology":"Oznaczanie węglowodorów C10-C40 metodą chromatografii gazowej z detektorem FID","methodology_en":"Determination of hydrocarbons C10-C40 by gas chromatography with FID detector","methodology_zh":"气相色谱-FID法测定C10-C40烃类","methodology_cs":"Stanovení uhlovodíků C10-C40 metodou plynové chromatografie s detektorem FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10-C40 metodą chromatografii gazowej z detektorem FID","reference":"SOP 102A (ČSN EN 14039)","norm_bases":["SOP 102A","ČSN EN 14039"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt, odpad stały, osad, osad denny Oznaczanie węglowodorów C10-C40 metodą chromatografii gazowej z detektorem FID Zemina, pevný odpad, kal, sediment Stanovení uhlovodíků C10-C40 metodou plynové chromatografie s detektorem FID SOP 102A (ČSN EN 14039) Grunt, odpad staly, osad, osad denny Oznaczanie weglowodorow C10-C40 metoda chromatografii gazowej z detektorem FID Zemina, pevny odpad, kal, sediment Stanoveni uhlovodiku C10-C40 metodou plynove chromatografie s detektorem FID SOP 102A (CSN EN 14039)","search_en":"Soil, solid waste, sludge, sediment Determination of hydrocarbons C10-C40 by gas chromatography with FID detector SOP 102A (ČSN EN 14039)","search_zh":"土壤、固体废物、污泥、沉积物 气相色谱-FID法测定C10-C40烃类 SOP 102A (ČSN EN 14039)","categories":["environment","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bb1ea275f93b787db72cdcf9","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"4","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie pestycydów chloroorganicznych (OCP) metodą chromatografii gazowej z detektorem ECD i sumy pestycydów obliczeniowo z wyników pomiarów","methodology_en":"Determination of organochlorine pesticides (OCP) by gas chromatography with ECD detector and total pesticides by calculation from measured values","methodology_zh":"气相色谱-ECD法测定有机氯农药（OCP），由测得值计算农药总量","methodology_cs":"Stanovení organochlorovaných pesticidů (OCP) metodou plynové chromatografie s detektorem ECD a pesticidních látek celkem výpočtem z naměřených hodnot","parameters":[{"name":"trifluralina","range":""},{"name":"heksachlorobenzen","range":""},{"name":"γ-heksachlorocykloheksan (lindan)","range":""},{"name":"heptachlor","range":""},{"name":"aldryna","range":""},{"name":"epoksyd heptachloru","range":""},{"name":"α-endosulfan","range":""},{"name":"4,4′-DDE","range":""},{"name":"dieldryna","range":""},{"name":"endryna","range":""},{"name":"β-endosulfan","range":""},{"name":"4,4′-DDD","range":""},{"name":"4,4′-DDT","range":""},{"name":"metoksychlor","range":""}],"parameters_en":[{"name":"trifluralin","range":""},{"name":"hexachlorobenzene","range":""},{"name":"γ-hexachlorocyclohexane (lindane)","range":""},{"name":"heptachlor","range":""},{"name":"aldrin","range":""},{"name":"heptachlor epoxide","range":""},{"name":"α-endosulfan","range":""},{"name":"4,4′-DDE","range":""},{"name":"dieldrin","range":""},{"name":"endrin","range":""},{"name":"β-endosulfan","range":""},{"name":"4,4′-DDD","range":""},{"name":"4,4′-DDT","range":""},{"name":"methoxychlor","range":""}],"parameters_zh":[{"name":"氟乐灵","range":""},{"name":"六氯苯","range":""},{"name":"γ-六六六（林丹）","range":""},{"name":"七氯","range":""},{"name":"艾氏剂","range":""},{"name":"环氧七氯","range":""},{"name":"α-硫丹","range":""},{"name":"4,4′-DDE","range":""},{"name":"狄氏剂","range":""},{"name":"异狄氏剂","range":""},{"name":"β-硫丹","range":""},{"name":"4,4′-DDD","range":""},{"name":"4,4′-DDT","range":""},{"name":"甲氧滴滴涕","range":""}],"parameters_cs":[{"name":"trifluralin","range":""},{"name":"hexachlorbenzen","range":""},{"name":"g-hexachlorcyklohexan (lindan)","range":""},{"name":"heptachlor","range":""},{"name":"aldrin","range":""},{"name":"heptachlorepoxid","range":""},{"name":"a-endosulfan","range":""},{"name":"4,4´- DDE","range":""},{"name":"dieldrin","range":""},{"name":"endrin","range":""},{"name":"b-endosulfan","range":""},{"name":"4,4´- DDD","range":""},{"name":"4,4´- DDT","range":""},{"name":"methoxychlor","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma pestycydów"],"computed_en":["total pesticides"],"computed_zh":["农药总量"],"computed_cs":["pesticidních látek celkem"],"activity":"Oznaczanie pestycydów chloroorganicznych (OCP) metodą chromatografii gazowej z detektorem ECD i sumy pestycydów obliczeniowo z wyników pomiarów\nZakres:\ntrifluralina\nheksachlorobenzen\nγ-heksachlorocykloheksan (lindan)\nheptachlor\naldryna\nepoksyd heptachloru\nα-endosulfan\n4,4′-DDE\ndieldryna\nendryna\nβ-endosulfan\n4,4′-DDD\n4,4′-DDT\nmetoksychlor","reference":"SOP 103 (ČSN EN ISO 6468)","norm_bases":["SOP 103","ČSN EN ISO 6468"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie pestycydów chloroorganicznych (OCP) metodą chromatografii gazowej z detektorem ECD i sumy pestycydów obliczeniowo z wyników pomiarów trifluralina  heksachlorobenzen  γ-heksachlorocykloheksan (lindan)  heptachlor  aldryna  epoksyd heptachloru  α-endosulfan  4,4′-DDE  dieldryna  endryna  β-endosulfan  4,4′-DDD  4,4′-DDT  metoksychlor  suma pestycydów Vody, voda odpadní Stanovení organochlorovaných pesticidů (OCP) metodou plynové chromatografie s detektorem ECD a pesticidních látek celkem výpočtem z naměřených hodnot trifluralin  hexachlorbenzen  g-hexachlorcyklohexan (lindan)  heptachlor  aldrin  heptachlorepoxid  a-endosulfan  4,4´- DDE  dieldrin  endrin  b-endosulfan  4,4´- DDD  4,4´- DDT  methoxychlor  pesticidních látek celkem SOP 103 (ČSN EN ISO 6468) Wody, scieki Oznaczanie pestycydow chloroorganicznych (OCP) metoda chromatografii gazowej z detektorem ECD i sumy pestycydow obliczeniowo z wynikow pomiarow trifluralina  heksachlorobenzen  γ-heksachlorocykloheksan (lindan)  heptachlor  aldryna  epoksyd heptachloru  α-endosulfan  4,4′-DDE  dieldryna  endryna  β-endosulfan  4,4′-DDD  4,4′-DDT  metoksychlor  suma pestycydow Vody, voda odpadni Stanoveni organochlorovanych pesticidu (OCP) metodou plynove chromatografie s detektorem ECD a pesticidnich latek celkem vypoctem z namerenych hodnot trifluralin  hexachlorbenzen  g-hexachlorcyklohexan (lindan)  heptachlor  aldrin  heptachlorepoxid  a-endosulfan  4,4´- DDE  dieldrin  endrin  b-endosulfan  4,4´- DDD  4,4´- DDT  methoxychlor  pesticidnich latek celkem SOP 103 (CSN EN ISO 6468)","search_en":"Waters, waste water Determination of organochlorine pesticides (OCP) by gas chromatography with ECD detector and total pesticides by calculation from measured values trifluralin  hexachlorobenzene  γ-hexachlorocyclohexane (lindane)  heptachlor  aldrin  heptachlor epoxide  α-endosulfan  4,4′-DDE  dieldrin  endrin  β-endosulfan  4,4′-DDD  4,4′-DDT  methoxychlor  total pesticides SOP 103 (ČSN EN ISO 6468)","search_zh":"水、废水 气相色谱-ECD法测定有机氯农药（OCP），由测得值计算农药总量 氟乐灵  六氯苯  γ-六六六（林丹）  七氯  艾氏剂  环氧七氯  α-硫丹  4,4′-DDE  狄氏剂  异狄氏剂  β-硫丹  4,4′-DDD  4,4′-DDT  甲氧滴滴涕  农药总量 SOP 103 (ČSN EN ISO 6468)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9fee05c927bfab2d6e4c3567","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"5","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wyników pomiarów","methodology_en":"Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detector and sum of PAH by calculation from measured values","methodology_zh":"HPLC-荧光检测法测定多环芳烃（PAH），由测得值计算PAH总量","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenčním detektorem a sumy PAU výpočtem z naměřených hodnot","parameters":[{"name":"naftalen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoranten","range":""},{"name":"piren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chryzen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(a)piren","range":""},{"name":"dibenzo(a,h)antracen","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""}],"parameters_en":[{"name":"naphthalene","range":""},{"name":"acenaphthene","range":""},{"name":"fluorene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"fluoranthene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"chrysene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"dibenzo(a,h)anthracene","range":""},{"name":"benzo(g,h,i)perylene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"苊","range":""},{"name":"芴","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"荧蒽","range":""},{"name":"芘","range":""},{"name":"苯并(a)蒽","range":""},{"name":"䓛","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"二苯并(a,h)蒽","range":""},{"name":"苯并(g,h,i)苝","range":""},{"name":"茚并(1,2,3-cd)芘","range":""}],"parameters_cs":[{"name":"naftalen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoranten","range":""},{"name":"pyren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chrysen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(a)pyren","range":""},{"name":"dibenzo(a,h)antracen","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-cd)pyren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma WWA"],"computed_en":["sum of PAH"],"computed_zh":["PAH总量"],"computed_cs":["sumy PAU"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wyników pomiarów\nZakres:\nnaftalen\nacenaften\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(g,h,i)perylen\nindeno(1,2,3-cd)piren","reference":"SOP 104 (ČSN EN ISO 17993)","norm_bases":["SOP 104","ČSN EN ISO 17993"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wyników pomiarów naftalen  acenaften  fluoren  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(g,h,i)perylen  indeno(1,2,3-cd)piren  suma WWA Vody, voda odpadní Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenčním detektorem a sumy PAU výpočtem z naměřených hodnot naftalen  acenaften  fluoren  fenantren  antracen  fluoranten  pyren  benzo(a)antracen  chrysen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)pyren  dibenzo(a,h)antracen  benzo(g,h,i)perylen  indeno(1,2,3-cd)pyren  sumy PAU SOP 104 (ČSN EN ISO 17993) Wody, scieki Oznaczanie wielopierscieniowych weglowodorow aromatycznych (WWA) metoda HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wynikow pomiarow naftalen  acenaften  fluoren  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(g,h,i)perylen  indeno(1,2,3-cd)piren  suma WWA Vody, voda odpadni Stanoveni polycyklickych aromatickych uhlovodiku (PAU) metodou HPLC s fluorescencnim detektorem a sumy PAU vypoctem z namerenych hodnot naftalen  acenaften  fluoren  fenantren  antracen  fluoranten  pyren  benzo(a)antracen  chrysen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)pyren  dibenzo(a,h)antracen  benzo(g,h,i)perylen  indeno(1,2,3-cd)pyren  sumy PAU SOP 104 (CSN EN ISO 17993)","search_en":"Waters, waste water Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detector and sum of PAH by calculation from measured values naphthalene  acenaphthene  fluorene  phenanthrene  anthracene  fluoranthene  pyrene  benzo(a)anthracene  chrysene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(a)pyrene  dibenzo(a,h)anthracene  benzo(g,h,i)perylene  indeno(1,2,3-cd)pyrene  sum of PAH SOP 104 (ČSN EN ISO 17993)","search_zh":"水、废水 HPLC-荧光检测法测定多环芳烃（PAH），由测得值计算PAH总量 萘  苊  芴  菲  蒽  荧蒽  芘  苯并(a)蒽  䓛  苯并(b)荧蒽  苯并(k)荧蒽  苯并(a)芘  二苯并(a,h)蒽  苯并(g,h,i)苝  茚并(1,2,3-cd)芘  PAH总量 SOP 104 (ČSN EN ISO 17993)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"39c0ec37a216e953639b140d","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"6","test_object":"Grunt, odpad stały, osad, osad denny","test_object_en":"Soil, solid waste, sludge, sediment","test_object_zh":"土壤、固体废物、污泥、沉积物","test_object_cs":"Zemina, pevný odpad, kal, sediment","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wyników pomiarów","methodology_en":"Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detector and sum of PAH by calculation from measured values","methodology_zh":"HPLC-荧光检测法测定多环芳烃（PAH），由测得值计算PAH总量","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenčním detektorem a sumy PAU výpočtem z naměřených hodnot","parameters":[{"name":"naftalen","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoranten","range":""},{"name":"piren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chryzen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(a)piren","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""}],"parameters_en":[{"name":"naphthalene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"fluoranthene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"chrysene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"benzo(g,h,i)perylene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"荧蒽","range":""},{"name":"芘","range":""},{"name":"苯并(a)蒽","range":""},{"name":"䓛","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"苯并(g,h,i)苝","range":""},{"name":"茚并(1,2,3-cd)芘","range":""}],"parameters_cs":[{"name":"naftalen","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoranten","range":""},{"name":"pyren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chrysen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(a)pyren","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-c,d)pyren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma WWA"],"computed_en":["sum of PAH"],"computed_zh":["PAH总量"],"computed_cs":["sumy PAU"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wyników pomiarów\nZakres:\nnaftalen\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\nbenzo(g,h,i)perylen\nindeno(1,2,3-cd)piren","reference":"SOP 104A (ČSN EN 17503)","norm_bases":["SOP 104A","ČSN EN 17503"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt, odpad stały, osad, osad denny Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wyników pomiarów naftalen  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  benzo(g,h,i)perylen  indeno(1,2,3-cd)piren  suma WWA Zemina, pevný odpad, kal, sediment Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenčním detektorem a sumy PAU výpočtem z naměřených hodnot naftalen  fenantren  antracen  fluoranten  pyren  benzo(a)antracen  chrysen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)pyren  benzo(g,h,i)perylen  indeno(1,2,3-c,d)pyren  sumy PAU SOP 104A (ČSN EN 17503) Grunt, odpad staly, osad, osad denny Oznaczanie wielopierscieniowych weglowodorow aromatycznych (WWA) metoda HPLC z detektorem fluorescencyjnym i sumy WWA obliczeniowo z wynikow pomiarow naftalen  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  benzo(g,h,i)perylen  indeno(1,2,3-cd)piren  suma WWA Zemina, pevny odpad, kal, sediment Stanoveni polycyklickych aromatickych uhlovodiku (PAU) metodou HPLC s fluorescencnim detektorem a sumy PAU vypoctem z namerenych hodnot naftalen  fenantren  antracen  fluoranten  pyren  benzo(a)antracen  chrysen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)pyren  benzo(g,h,i)perylen  indeno(1,2,3-c,d)pyren  sumy PAU SOP 104A (CSN EN 17503)","search_en":"Soil, solid waste, sludge, sediment Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detector and sum of PAH by calculation from measured values naphthalene  phenanthrene  anthracene  fluoranthene  pyrene  benzo(a)anthracene  chrysene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(a)pyrene  benzo(g,h,i)perylene  indeno(1,2,3-cd)pyrene  sum of PAH SOP 104A (ČSN EN 17503)","search_zh":"土壤、固体废物、污泥、沉积物 HPLC-荧光检测法测定多环芳烃（PAH），由测得值计算PAH总量 萘  菲  蒽  荧蒽  芘  苯并(a)蒽  䓛  苯并(b)荧蒽  苯并(k)荧蒽  苯并(a)芘  苯并(g,h,i)苝  茚并(1,2,3-cd)芘  PAH总量 SOP 104A (ČSN EN 17503)","categories":["environment","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e959f4e1292692faed0be6b0","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"7","test_object":"Wody, ścieki","test_object_en":"Waters, waste water","test_object_zh":"水、废水","test_object_cs":"Vody, voda odpadní","methodology":"Oznaczanie polichlorowanych bifenyli (PCB) metodą chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wyników pomiarów","methodology_en":"Determination of polychlorinated biphenyls (PCB) by gas chromatography with ECD detector and sum of PCB by calculation from measured values","methodology_zh":"气相色谱-ECD法测定多氯联苯（PCB），由测得值计算PCB总量","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB) metodou plynové chromatografie s detektorem ECD a sumy PCB výpočtem z naměřených hodnot","parameters":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"parameters_en":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"parameters_zh":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"parameters_cs":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCB"],"computed_en":["sum of PCB"],"computed_zh":["PCB总量"],"computed_cs":["sumy PCB"],"activity":"Oznaczanie polichlorowanych bifenyli (PCB) metodą chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wyników pomiarów\nZakres:\nPCB 28\nPCB 52\nPCB 101\nPCB 118\nPCB 138\nPCB 153\nPCB 180","reference":"SOP 105 (ČSN EN ISO 6468)","norm_bases":["SOP 105","ČSN EN ISO 6468"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne)","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions)","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky)","search_text":"Wody, ścieki Oznaczanie polichlorowanych bifenyli (PCB) metodą chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wyników pomiarów PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  suma PCB Vody, voda odpadní Stanovení polychlorovaných bifenylů (PCB) metodou plynové chromatografie s detektorem ECD a sumy PCB výpočtem z naměřených hodnot PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  sumy PCB SOP 105 (ČSN EN ISO 6468) Wody, scieki Oznaczanie polichlorowanych bifenyli (PCB) metoda chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wynikow pomiarow PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  suma PCB Vody, voda odpadni Stanoveni polychlorovanych bifenylu (PCB) metodou plynove chromatografie s detektorem ECD a sumy PCB vypoctem z namerenych hodnot PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  sumy PCB SOP 105 (CSN EN ISO 6468)","search_en":"Waters, waste water Determination of polychlorinated biphenyls (PCB) by gas chromatography with ECD detector and sum of PCB by calculation from measured values PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  sum of PCB SOP 105 (ČSN EN ISO 6468)","search_zh":"水、废水 气相色谱-ECD法测定多氯联苯（PCB），由测得值计算PCB总量 PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  PCB总量 SOP 105 (ČSN EN ISO 6468)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"720c488015cb432b2f6c226d","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"8","test_object":"Grunt, odpad stały, osad, osad denny","test_object_en":"Soil, solid waste, sludge, sediment","test_object_zh":"土壤、固体废物、污泥、沉积物","test_object_cs":"Zemina, pevný odpad, kal, sediment","methodology":"Oznaczanie polichlorowanych bifenyli (PCB) metodą chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wyników pomiarów","methodology_en":"Determination of polychlorinated biphenyls (PCB) by gas chromatography with ECD detector and sum of PCB by calculation from measured values","methodology_zh":"气相色谱-ECD法测定多氯联苯（PCB），由测得值计算PCB总量","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB) metodou plynové chromatografie s detektorem ECD a sumy PCB výpočtem z naměřených hodnot","parameters":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"parameters_en":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"parameters_zh":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"parameters_cs":[{"name":"PCB 28","range":""},{"name":"PCB 52","range":""},{"name":"PCB 101","range":""},{"name":"PCB 118","range":""},{"name":"PCB 138","range":""},{"name":"PCB 153","range":""},{"name":"PCB 180","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCB"],"computed_en":["sum of PCB"],"computed_zh":["PCB总量"],"computed_cs":["sumy PCB"],"activity":"Oznaczanie polichlorowanych bifenyli (PCB) metodą chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wyników pomiarów\nZakres:\nPCB 28\nPCB 52\nPCB 101\nPCB 118\nPCB 138\nPCB 153\nPCB 180","reference":"SOP 105A (ČSN EN ISO 18475)","norm_bases":["SOP 105A","ČSN EN ISO 18475"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt, odpad stały, osad, osad denny Oznaczanie polichlorowanych bifenyli (PCB) metodą chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wyników pomiarów PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  suma PCB Zemina, pevný odpad, kal, sediment Stanovení polychlorovaných bifenylů (PCB) metodou plynové chromatografie s detektorem ECD a sumy PCB výpočtem z naměřených hodnot PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  sumy PCB SOP 105A (ČSN EN ISO 18475) Grunt, odpad staly, osad, osad denny Oznaczanie polichlorowanych bifenyli (PCB) metoda chromatografii gazowej z detektorem ECD i sumy PCB obliczeniowo z wynikow pomiarow PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  suma PCB Zemina, pevny odpad, kal, sediment Stanoveni polychlorovanych bifenylu (PCB) metodou plynove chromatografie s detektorem ECD a sumy PCB vypoctem z namerenych hodnot PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  sumy PCB SOP 105A (CSN EN ISO 18475)","search_en":"Soil, solid waste, sludge, sediment Determination of polychlorinated biphenyls (PCB) by gas chromatography with ECD detector and sum of PCB by calculation from measured values PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  sum of PCB SOP 105A (ČSN EN ISO 18475)","search_zh":"土壤、固体废物、污泥、沉积物 气相色谱-ECD法测定多氯联苯（PCB），由测得值计算PCB总量 PCB 28  PCB 52  PCB 101  PCB 118  PCB 138  PCB 153  PCB 180  PCB总量 SOP 105A (ČSN EN ISO 18475)","categories":["environment","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"260f7f4a46d7ed61490dccda","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"9","test_object":"Wody, ścieki, wyciągi","test_object_en":"Waters, waste water, leachates","test_object_zh":"水、废水、浸出液","test_object_cs":"Vody, voda odpadní, výluhy","methodology":"Oznaczanie pierwiastków metodą ICP-MS","methodology_en":"Determination of elements by ICP-MS","methodology_zh":"ICP-MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP-MS","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Lit (Li)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Uran (U)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Lithium (Li)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Uranium (U)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"锂（Li）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"锶（Sr）","range":""},{"name":"铊（Tl）","range":""},{"name":"铀（U）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Li","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Sr","range":""},{"name":"Tl","range":""},{"name":"U","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["twardość ogólna (suma Ca+Mg)"],"computed_en":["total hardness (sum of Ca+Mg)"],"computed_zh":["总硬度（Ca+Mg总量）"],"computed_cs":["celková tvrdost (suma Ca+Mg)"],"activity":"Oznaczanie pierwiastków metodą ICP-MS\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nLit (Li)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nStront (Sr)\nTal (Tl)\nUran (U)\nWanad (V)\nCynk (Zn)","reference":"SOP 106 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","norm_bases":["SOP 106","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody (woda pitna, ciepła, uzdatniona, wyprodukowana, surowa, podziemna, powierzchniowa, opadowa, użytkowa, do nawadniania, przemysłowa, kotłowa, grzewcza, woda w kąpieliskach, roztwory wodne). Wyciągi – wyciągi i wyciągi wodne z próbek stałych przygotowane wg ustawy o odpadach nr 541/2020 Sb.","note_en":"Waters (drinking, hot, treated, produced, raw, ground, surface, rain, service, irrigation, industrial, boiler, heating water, bathing water, aqueous solutions). Leachates – leachates and aqueous leachates of solid samples prepared according to Waste Act No. 541/2020 Coll.","note_zh":"水（饮用水、热水、处理水、制备水、原水、地下水、地表水、雨水、杂用水、灌溉水、工业用水、锅炉水、供暖水、游泳用水、水溶液）。浸出液 – 按第541/2020 Sb.号废物法制备的固体样品浸出液和水浸出液","note_cs":"Vody (voda pitná, teplá, upravená, vyrobená, surová, podzemní, povrchová, srážková, užitková, závlahová, průmyslová, kotlová, topná, voda ke koupání, vodné roztoky). Výluhy – výluhy a vodné výluhy pevných vzorků připravené dle zákona o odpadech č. 541/2020 Sb.","search_text":"Wody, ścieki, wyciągi Oznaczanie pierwiastków metodą ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Stront (Sr)  Tal (Tl)  Uran (U)  Wanad (V)  Cynk (Zn)  twardość ogólna (suma Ca+Mg) Vody, voda odpadní, výluhy Stanovení prvků metodou ICP-MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Sr  Tl  U  V  Zn  celková tvrdost (suma Ca+Mg) SOP 106 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2) Wody, scieki, wyciagi Oznaczanie pierwiastkow metoda ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Stront (Sr)  Tal (Tl)  Uran (U)  Wanad (V)  Cynk (Zn)  twardosc ogolna (suma Ca+Mg) Vody, voda odpadni, vyluhy Stanoveni prvku metodou ICP-MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Sr  Tl  U  V  Zn  celkova tvrdost (suma Ca+Mg) SOP 106 (CSN EN ISO 17294-1; CSN EN ISO 17294-2)","search_en":"Waters, waste water, leachates Determination of elements by ICP-MS Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Lithium (Li)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Strontium (Sr)  Thallium (Tl)  Uranium (U)  Vanadium (V)  Zinc (Zn)  total hardness (sum of Ca+Mg) SOP 106 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","search_zh":"水、废水、浸出液 ICP-MS法测定元素 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  锂（Li）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  锶（Sr）  铊（Tl）  铀（U）  钒（V）  锌（Zn）  总硬度（Ca+Mg总量） SOP 106 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc6952b2213c8ff5c9785103","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"10","test_object":"Grunt, odpad, osad, osad denny, nawozy","test_object_en":"Soil, waste, sludge, sediment, fertilisers","test_object_zh":"土壤、废物、污泥、沉积物、肥料","test_object_cs":"Zemina, odpad, kal, sediment, hnojiva","methodology":"Oznaczanie pierwiastków metodą ICP-MS","methodology_en":"Determination of elements by ICP-MS","methodology_zh":"ICP-MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP-MS","parameters":[{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"As","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["CaO (tlenek wapnia)","MgO (tlenek magnezu)","K2O (tlenek potasu)","P2O5 (pentatlenek fosforu)"],"computed_en":["CaO (calcium oxide)","MgO (magnesium oxide)","K2O (potassium oxide)","P2O5 (phosphorus pentoxide)"],"computed_zh":["CaO（氧化钙）","MgO（氧化镁）","K2O（氧化钾）","P2O5（五氧化二磷）"],"computed_cs":["CaO","MgO","K2O","P2O5"],"activity":"Oznaczanie pierwiastków metodą ICP-MS\nZakres:\nGlin (Al)\nArsen (As)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nWanad (V)\nCynk (Zn)","reference":"SOP 106A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171)","norm_bases":["SOP 106A","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2","ČSN EN 16171"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Odpad – stały, ciekły, bioodpad, materiały budowlane i rozbiórkowe. Bioodpad – kompost, surowce wsadowe do kompostowania. Nawozy – komposty, nawozy organiczne, organiczno-mineralne, mineralne, wapniowe i środki wspomagające uprawę (woda technologiczna)","note_en":"Waste – solid, liquid, biowaste, construction and demolition materials. Biowaste – compost, input materials for composting. Fertilisers – composts, organic, organo-mineral, mineral, calcareous fertilisers and soil improvers (process water)","note_zh":"废物 – 固体、液体、生物废物、建筑和拆除材料。生物废物 – 堆肥、堆肥原料。肥料 – 堆肥、有机肥、有机无机复混肥、矿物肥、石灰质肥料和土壤改良剂（工艺用水）","note_cs":"Odpad – pevný, kapalný, bioodpad, stavební a demoliční materiály. Bioodpad – kompost, vstupní suroviny do kompostů. Hnojiva – komposty, organická, organominerální, minerální, vápenatá hnojiva a pomocné půdní látky (technologická voda)","search_text":"Grunt, odpad, osad, osad denny, nawozy Oznaczanie pierwiastków metodą ICP-MS Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  CaO (tlenek wapnia) MgO (tlenek magnezu) K2O (tlenek potasu) P2O5 (pentatlenek fosforu) Zemina, odpad, kal, sediment, hnojiva Stanovení prvků metodou ICP-MS Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Ni  P  Pb  V  Zn  CaO MgO K2O P2O5 SOP 106A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171) Grunt, odpad, osad, osad denny, nawozy Oznaczanie pierwiastkow metoda ICP-MS Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Wanad (V)  Cynk (Zn)  CaO (tlenek wapnia) MgO (tlenek magnezu) K2O (tlenek potasu) P2O5 (pentatlenek fosforu) Zemina, odpad, kal, sediment, hnojiva Stanoveni prvku metodou ICP-MS Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Ni  P  Pb  V  Zn  CaO MgO K2O P2O5 SOP 106A (CSN EN ISO 17294-1; CSN EN ISO 17294-2; CSN EN 16171)","search_en":"Soil, waste, sludge, sediment, fertilisers Determination of elements by ICP-MS Aluminium (Al)  Arsenic (As)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  CaO (calcium oxide) MgO (magnesium oxide) K2O (potassium oxide) P2O5 (phosphorus pentoxide) SOP 106A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171)","search_zh":"土壤、废物、污泥、沉积物、肥料 ICP-MS法测定元素 铝（Al）  砷（As）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  镍（Ni）  磷（P）  铅（Pb）  钒（V）  锌（Zn）  CaO（氧化钙） MgO（氧化镁） K2O（氧化钾） P2O5（五氧化二磷） SOP 106A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7259413519b0a6a61b0182b4","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"11","test_object":"Materiał roślinny, pasze, żywność, nawozy","test_object_en":"Plant material, feeds, foods, fertilisers","test_object_zh":"植物材料、饲料、食品、肥料","test_object_cs":"Rostlinný materiál, krmiva, potraviny, hnojiva","methodology":"Oznaczanie pierwiastków metodą ICP-MS","methodology_en":"Determination of elements by ICP-MS","methodology_zh":"ICP-MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP-MS","parameters":[{"name":"Arsen (As)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["CaO (tlenek wapnia)","MgO (tlenek magnezu)","K2O (tlenek potasu)","P2O5 (pentatlenek fosforu)"],"computed_en":["CaO (calcium oxide)","MgO (magnesium oxide)","K2O (potassium oxide)","P2O5 (phosphorus pentoxide)"],"computed_zh":["CaO（氧化钙）","MgO（氧化镁）","K2O（氧化钾）","P2O5（五氧化二磷）"],"computed_cs":["CaO","MgO","K2O","P2O5"],"activity":"Oznaczanie pierwiastków metodą ICP-MS\nZakres:\nArsen (As)\nWapń (Ca)\nKadm (Cd)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nFosfor (P)\nOłów (Pb)\nCynk (Zn)","reference":"SOP 106B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; JPP ÚKZÚZ č. postupu 10310.1, 10326.1, 10410.1, 10440.1, 10470.1, 20062.1, 40018.1, 40034.1, 40224.1)","norm_bases":["SOP 106B","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2","JPP ÚKZÚZ č. postupu 10310.1, 10326.1, 10410.1, 10440.1, 10470.1, 20062.1, 40018.1, 40034.1, 40224.1"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Nawozy – komposty, nawozy organiczne, organiczno-mineralne, mineralne, wapniowe i środki wspomagające uprawę (woda technologiczna)","note_en":"Fertilisers – composts, organic, organo-mineral, mineral, calcareous fertilisers and soil improvers (process water)","note_zh":"肥料 – 堆肥、有机肥、有机无机复混肥、矿物肥、石灰质肥料和土壤改良剂（工艺用水）","note_cs":"Hnojiva – komposty, organická, organominerální, minerální, vápenatá hnojiva a pomocné půdní látky (technologická voda)","search_text":"Materiał roślinny, pasze, żywność, nawozy Oznaczanie pierwiastków metodą ICP-MS Arsen (As)  Wapń (Ca)  Kadm (Cd)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Fosfor (P)  Ołów (Pb)  Cynk (Zn)  CaO (tlenek wapnia) MgO (tlenek magnezu) K2O (tlenek potasu) P2O5 (pentatlenek fosforu) Rostlinný materiál, krmiva, potraviny, hnojiva Stanovení prvků metodou ICP-MS As  Ca  Cd  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  P  Pb  Zn  CaO MgO K2O P2O5 SOP 106B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; JPP ÚKZÚZ č. postupu 10310.1, 10326.1, 10410.1, 10440.1, 10470.1, 20062.1, 40018.1, 40034.1, 40224.1) Material roslinny, pasze, zywnosc, nawozy Oznaczanie pierwiastkow metoda ICP-MS Arsen (As)  Wapn (Ca)  Kadm (Cd)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Fosfor (P)  Olow (Pb)  Cynk (Zn)  CaO (tlenek wapnia) MgO (tlenek magnezu) K2O (tlenek potasu) P2O5 (pentatlenek fosforu) Rostlinny material, krmiva, potraviny, hnojiva Stanoveni prvku metodou ICP-MS As  Ca  Cd  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  P  Pb  Zn  CaO MgO K2O P2O5 SOP 106B (CSN EN ISO 17294-1; CSN EN ISO 17294-2; JPP UKZUZ c. postupu 10310.1, 10326.1, 10410.1, 10440.1, 10470.1, 20062.1, 40018.1, 40034.1, 40224.1)","search_en":"Plant material, feeds, foods, fertilisers Determination of elements by ICP-MS Arsenic (As)  Calcium (Ca)  Cadmium (Cd)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Phosphorus (P)  Lead (Pb)  Zinc (Zn)  CaO (calcium oxide) MgO (magnesium oxide) K2O (potassium oxide) P2O5 (phosphorus pentoxide) SOP 106B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; JPP ÚKZÚZ č. postupu 10310.1, 10326.1, 10410.1, 10440.1, 10470.1, 20062.1, 40018.1, 40034.1, 40224.1)","search_zh":"植物材料、饲料、食品、肥料 ICP-MS法测定元素 砷（As）  钙（Ca）  镉（Cd）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  磷（P）  铅（Pb）  锌（Zn）  CaO（氧化钙） MgO（氧化镁） K2O（氧化钾） P2O5（五氧化二磷） SOP 106B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; JPP ÚKZÚZ č. postupu 10310.1, 10326.1, 10410.1, 10440.1, 10470.1, 20062.1, 40018.1, 40034.1, 40224.1)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bcf0e60eaafde505d13fa075","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna, surowa, wyprodukowana, ciepła","test_object_en":"Drinking, raw, produced and hot water","test_object_zh":"饮用水、原水、制备水、热水","test_object_cs":"Voda pitná, surová, vyrobená, teplá","methodology":"Pobieranie próbek wód pitnych","methodology_en":"Sampling of drinking water","methodology_zh":"饮用水采样","methodology_cs":"Odběr vzorků pitných vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód pitnych","reference":"SOP VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","norm_bases":["SOP VZ 01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-5","ČSN EN ISO 5667-14","ČSN EN ISO 19458","TNV 75 7055"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, wyprodukowana, ciepła Pobieranie próbek wód pitnych Voda pitná, surová, vyrobená, teplá Odběr vzorků pitných vod SOP VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055) Woda pitna, surowa, wyprodukowana, ciepla Pobieranie probek wod pitnych Voda pitna, surova, vyrobena, tepla Odber vzorku pitnych vod SOP VZ 01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-5; CSN EN ISO 5667-14; CSN EN ISO 19458; TNV 75 7055)","search_en":"Drinking, raw, produced and hot water Sampling of drinking water SOP VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","search_zh":"饮用水、原水、制备水、热水 饮用水采样 SOP VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e33753679f662efee7fec0e6","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"2","test_object":"Woda podziemna","test_object_en":"Ground water","test_object_zh":"地下水","test_object_cs":"Voda podzemní","methodology":"Pobieranie próbek wód podziemnych (pobór statyczny i dynamiczny)","methodology_en":"Sampling of ground water (static and dynamic sampling)","methodology_zh":"地下水采样（静态采样和动态采样）","methodology_cs":"Odběr vzorků podzemních vod (statický odběr a dynamický odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód podziemnych (pobór statyczny i dynamiczny)","reference":"SOP VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","norm_bases":["SOP VZ 02","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-11","ČSN EN ISO 5667-14","ČSN EN ISO 19458","TNV 75 7055"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda podziemna Pobieranie próbek wód podziemnych (pobór statyczny i dynamiczny) Voda podzemní Odběr vzorků podzemních vod (statický odběr a dynamický odběr) SOP VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055) Woda podziemna Pobieranie probek wod podziemnych (pobor statyczny i dynamiczny) Voda podzemni Odber vzorku podzemnich vod (staticky odber a dynamicky odber) SOP VZ 02 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-11; CSN EN ISO 5667-14; CSN EN ISO 19458; TNV 75 7055)","search_en":"Ground water Sampling of ground water (static and dynamic sampling) SOP VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","search_zh":"地下水 地下水采样（静态采样和动态采样） SOP VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43565cf4022108f645259567","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"3","test_object":"Woda powierzchniowa","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Voda povrchová","methodology":"Pobieranie próbek wód powierzchniowych (pobór ręczny i próbnikiem)","methodology_en":"Sampling of surface water (manual sampling and sampling with a sampler)","methodology_zh":"地表水采样（人工采样和采样器采样）","methodology_cs":"Odběr vzorků povrchových vod (manuální odběr a odběr vzorkovačem)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych (pobór ręczny i próbnikiem)","reference":"SOP VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","norm_bases":["SOP VZ 03","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14","ČSN EN ISO 19458","TNV 75 7055"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda powierzchniowa Pobieranie próbek wód powierzchniowych (pobór ręczny i próbnikiem) Voda povrchová Odběr vzorků povrchových vod (manuální odběr a odběr vzorkovačem) SOP VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055) Woda powierzchniowa Pobieranie probek wod powierzchniowych (pobor reczny i probnikiem) Voda povrchova Odber vzorku povrchovych vod (manualni odber a odber vzorkovacem) SOP VZ 03 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN EN ISO 5667-6; CSN EN ISO 5667-14; CSN EN ISO 19458; TNV 75 7055)","search_en":"Surface water Sampling of surface water (manual sampling and sampling with a sampler) SOP VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","search_zh":"地表水 地表水采样（人工采样和采样器采样） SOP VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"45ec837fb2156b22abbfad04","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"4","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Voda odpadní","methodology":"Pobieranie próbek ścieków (pobór ręczny i automatycznym próbnikiem)","methodology_en":"Sampling of waste water (manual sampling and sampling with an automatic sampler)","methodology_zh":"废水采样（人工采样和自动采样器采样）","methodology_cs":"Odběr vzorků odpadních vod (manuální odběr a odběr automatickým vzorkovačem)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków (pobór ręczny i automatycznym próbnikiem)","reference":"SOP VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","norm_bases":["SOP VZ 04","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 75 7315"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków (pobór ręczny i automatycznym próbnikiem) Voda odpadní Odběr vzorků odpadních vod (manuální odběr a odběr automatickým vzorkovačem) SOP VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) Scieki Pobieranie probek sciekow (pobor reczny i automatycznym probnikiem) Voda odpadni Odber vzorku odpadnich vod (manualni odber a odber automatickym vzorkovacem) SOP VZ 04 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 75 7315)","search_en":"Waste water Sampling of waste water (manual sampling and sampling with an automatic sampler) SOP VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","search_zh":"废水 废水采样（人工采样和自动采样器采样） SOP VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3980b5cfe5e5043d5e9ca549","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"5","test_object":"Woda w kąpieliskach","test_object_en":"Bathing water","test_object_zh":"游泳用水","test_object_cs":"Voda ke koupání","methodology":"Pobieranie próbek wód w kąpieliskach","methodology_en":"Sampling of bathing water","methodology_zh":"游泳用水采样","methodology_cs":"Odběr vzorků vod ke koupání","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód w kąpieliskach","reference":"SOP VZ 09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. MZ č. 238/2011 Sb.)","norm_bases":["SOP VZ 09","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14","ČSN EN ISO 19458","Vyhl. MZ č. 238/2011 Sb."],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda w kąpieliskach Pobieranie próbek wód w kąpieliskach Voda ke koupání Odběr vzorků vod ke koupání SOP VZ 09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. MZ č. 238/2011 Sb.) Woda w kapieliskach Pobieranie probek wod w kapieliskach Voda ke koupani Odber vzorku vod ke koupani SOP VZ 09 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN EN ISO 5667-6; CSN EN ISO 5667-14; CSN EN ISO 19458; Vyhl. MZ c. 238/2011 Sb.)","search_en":"Bathing water Sampling of bathing water SOP VZ 09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. MZ č. 238/2011 Sb.)","search_zh":"游泳用水 游泳用水采样 SOP VZ 09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. MZ č. 238/2011 Sb.)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"db1c447f908b7dda7345840d","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"6","test_object":"Odpad – stały, ciekły, bioodpad, materiały budowlane i rozbiórkowe","test_object_en":"Waste – solid, liquid, biowaste, construction and demolition materials","test_object_zh":"废物 – 固体、液体、生物废物、建筑和拆除材料","test_object_cs":"Odpad – pevný, kapalný, bioodpad, stavební a demoliční materiály","methodology":"Pobieranie próbek odpadów","methodology_en":"Sampling of waste","methodology_zh":"废物采样","methodology_cs":"Odběr vzorků odpadů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek odpadów","reference":"SOP VZ 05 (ČSN EN 14899; Metodický pokyn č. 6 ke vzorkování odpadů, Věstník MŽP ČR č. 4/2008; ČSN EN 16179; ČSN 46 5735)","norm_bases":["SOP VZ 05","ČSN EN 14899","Metodický pokyn č. 6 ke vzorkování odpadů, Věstník MŽP ČR č. 4/2008","ČSN EN 16179","ČSN 46 5735"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odpad – stały, ciekły, bioodpad, materiały budowlane i rozbiórkowe Pobieranie próbek odpadów Odpad – pevný, kapalný, bioodpad, stavební a demoliční materiály Odběr vzorků odpadů SOP VZ 05 (ČSN EN 14899; Metodický pokyn č. 6 ke vzorkování odpadů, Věstník MŽP ČR č. 4/2008; ČSN EN 16179; ČSN 46 5735) Odpad – staly, ciekly, bioodpad, materialy budowlane i rozbiorkowe Pobieranie probek odpadow Odpad – pevny, kapalny, bioodpad, stavebni a demolicni materialy Odber vzorku odpadu SOP VZ 05 (CSN EN 14899; Metodicky pokyn c. 6 ke vzorkovani odpadu, Vestnik MZP CR c. 4/2008; CSN EN 16179; CSN 46 5735)","search_en":"Waste – solid, liquid, biowaste, construction and demolition materials Sampling of waste SOP VZ 05 (ČSN EN 14899; Metodický pokyn č. 6 ke vzorkování odpadů, Věstník MŽP ČR č. 4/2008; ČSN EN 16179; ČSN 46 5735)","search_zh":"废物 – 固体、液体、生物废物、建筑和拆除材料 废物采样 SOP VZ 05 (ČSN EN 14899; Metodický pokyn č. 6 ke vzorkování odpadů, Věstník MŽP ČR č. 4/2008; ČSN EN 16179; ČSN 46 5735)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c4f9a9e6d94517235450877","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"7","test_object":"Grunt (gleba)","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Zemina","methodology":"Pobieranie próbek gruntów","methodology_en":"Sampling of soil","methodology_zh":"土壤采样","methodology_cs":"Odběr vzorků zemin","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gruntów","reference":"SOP VZ 06 (ČSN 01 5111)","norm_bases":["SOP VZ 06","ČSN 01 5111"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt (gleba) Pobieranie próbek gruntów Zemina Odběr vzorků zemin SOP VZ 06 (ČSN 01 5111) Grunt (gleba) Pobieranie probek gruntow Zemina Odber vzorku zemin SOP VZ 06 (CSN 01 5111)","search_en":"Soil Sampling of soil SOP VZ 06 (ČSN 01 5111)","search_zh":"土壤 土壤采样 SOP VZ 06 (ČSN 01 5111)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"756c963e415f5e4bb51d051d","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"8","test_object":"Osad","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kal","methodology":"Pobieranie próbek osadów ściekowych","methodology_en":"Sampling of sewage sludge","methodology_zh":"污水处理厂污泥采样","methodology_cs":"Odběr vzorků čistírenských kalů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów ściekowych","reference":"SOP VZ 07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179)","norm_bases":["SOP VZ 07","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-13","ČSN EN ISO 5667-14","ČSN EN ISO 5667-15","ČSN EN 16179"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad Pobieranie próbek osadów ściekowych Kal Odběr vzorků čistírenských kalů SOP VZ 07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179) Osad Pobieranie probek osadow sciekowych Kal Odber vzorku cistirenskych kalu SOP VZ 07 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-13; CSN EN ISO 5667-14; CSN EN ISO 5667-15; CSN EN 16179)","search_en":"Sludge Sampling of sewage sludge SOP VZ 07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179)","search_zh":"污泥 污水处理厂污泥采样 SOP VZ 07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179)","categories":["environment","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"17bc01d91240a1d829fb75d2","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"9","test_object":"Osad denny","test_object_en":"Sediment","test_object_zh":"沉积物","test_object_cs":"Sediment","methodology":"Pobieranie próbek osadów dennych","methodology_en":"Sampling of bottom sediments","methodology_zh":"底泥采样","methodology_cs":"Odběr vzorků dnových sedimentů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów dennych","reference":"SOP VZ 08 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ISO 11277:2020/Amd.1:2024(en); ČSN EN 14899)","norm_bases":["SOP VZ 08","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-12","ČSN EN ISO 5667-14","ČSN EN ISO 5667-15","ISO 11277:2020/Amd.1:2024(en)","ČSN EN 14899"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad denny Pobieranie próbek osadów dennych Sediment Odběr vzorků dnových sedimentů SOP VZ 08 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ISO 11277:2020/Amd.1:2024(en); ČSN EN 14899) Osad denny Pobieranie probek osadow dennych Sediment Odber vzorku dnovych sedimentu SOP VZ 08 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-12; CSN EN ISO 5667-14; CSN EN ISO 5667-15; ISO 11277:2020/Amd.1:2024(en); CSN EN 14899)","search_en":"Sediment Sampling of bottom sediments SOP VZ 08 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ISO 11277:2020/Amd.1:2024(en); ČSN EN 14899)","search_zh":"沉积物 底泥采样 SOP VZ 08 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ISO 11277:2020/Amd.1:2024(en); ČSN EN 14899)","categories":["environment","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a4441dc1cf3254f5dda38365","lab_id":"69ad52a4de79e566650fd3c6","country":"CZ","accr_number":"1406","accr_body":"ČIA","row_label":"10","test_object":"Produkty rolne, owoce i warzywa","test_object_en":"Agricultural products, fruit and vegetables","test_object_zh":"农产品、水果和蔬菜","test_object_cs":"Zemědělské produkty, ovoce a zelenina","methodology":"Pobieranie próbek produktów rolnych do oznaczania wskaźników chemicznych","methodology_en":"Sampling of agricultural products for determination of chemical indicators","methodology_zh":"农产品化学指标测定采样","methodology_cs":"Odběr vzorků zemědělských produktů pro stanovení chemických ukazatelů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek produktów rolnych do oznaczania wskaźników chemicznych","reference":"SOP VZ 10 (ČSN 56 0253; Metodický pokyn č. 1/2022 MZe ČR)","norm_bases":["SOP VZ 10","ČSN 56 0253","Metodický pokyn č. 1/2022 MZe ČR"],"lab_section":"Laboratorium Metod Specjalnych i Dział Pobierania Próbek","lab_section_en":"Laboratory of Special Methods and Sampling Section","lab_section_zh":"专项方法实验室和采样组","lab_section_cs":"Laboratoř speciálních metod a úsek vzorkování","lab_address":"Nad Kunšovcem 1405/2, 594 01 Velké Meziříčí","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Produkty rolne, owoce i warzywa Pobieranie próbek produktów rolnych do oznaczania wskaźników chemicznych Zemědělské produkty, ovoce a zelenina Odběr vzorků zemědělských produktů pro stanovení chemických ukazatelů SOP VZ 10 (ČSN 56 0253; Metodický pokyn č. 1/2022 MZe ČR) Produkty rolne, owoce i warzywa Pobieranie probek produktow rolnych do oznaczania wskaznikow chemicznych Zemedelske produkty, ovoce a zelenina Odber vzorku zemedelskych produktu pro stanoveni chemickych ukazatelu SOP VZ 10 (CSN 56 0253; Metodicky pokyn c. 1/2022 MZe CR)","search_en":"Agricultural products, fruit and vegetables Sampling of agricultural products for determination of chemical indicators SOP VZ 10 (ČSN 56 0253; Metodický pokyn č. 1/2022 MZe ČR)","search_zh":"农产品、水果和蔬菜 农产品化学指标测定采样 SOP VZ 10 (ČSN 56 0253; Metodický pokyn č. 1/2022 MZe ČR)","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}